Sie sind auf Seite 1von 6

STRUCTURAL GLAZING for New Class RO

15

STRUCTURAL GLAZING
Providing and fixing glazing using Aluminium extruded built up
sections of approved make/Size conforming to alloy 63400 as per IS:
733 and 1S 1285 natural anodised/Powder Coated ( as per shade
finalized by Architecht) to AC 20 - 25 grade microns fabricated out of
heavy duty aluminium extruded profile, EPDM gasket, silicon sealant.
The structural glazing has fixed panels and partly openable.

The glazing members shall be designed for wind pressure upto 8 m


high as per drawings and details enclosed.
The Contractor must provide alternative design giving details of
structural calculations of the mullions and transomes offered, and
also provide drawings of individual profiles and also details of any
other profiles, wherever necessary, that may be used - clearly
indicating all dimensions, wall thickness and weight Kg./m.( The shop
drawing for complete glazing Work is in scope of Contractor only &
has to be get approved by Architecht)
All profiles shall be natural anodised to AC 20 - 25 grade
micron/Powder coated as per shade finalzed by Architecht. All profiles
shall be provided with Masking Tapes to provide safety against
external scratches at site. (Masking Tapes to be removed only at the
time of handing over as per the instructions of Site-In-Charge /
Architect).
The anchoring / bracing of the glazings to the steel beams / columns
shall be done with non-corrossive galvanised brackets of approved
design, (Galvanising to be done conforming to IS:4759-1996 upto
610 gms. per sqm. (80-90 micron thickness) with two numbers on
each beam, one normal bracket and one restrain bracket, (design for
brackets to be submitted for approval) including providing and fixing
of aluminium shims of various thickness to adjust the beam level/line
variations with expansion fasteners of approved make to withstand
the dead load of the glazings as well as stresses due to wind
pressure etc. Calculations for pull out load of expansion fasteners to
be got approved by architect.

The glazing frame shall be aligned for the entire height and for the
entire width of each Transom by lazer beam equipment to ensure 100
percent 'X' axis and 'Y' axis alignment.
The glazing framework shall be provided with approved in-built
ventilation and drainage system and the entire joint must be properly
sealed with weather silicon to make the joint water tight. The details
for in-built ventilation system to be submitted by the contractor and
got approved by the Architect.

The system should also provide for pressure equalisation. The details
for pressure equalization to be submitted by the contractor and got
approved by the Architect.
EPDM gaskets of suitable profiles to accommodate glasses in all the
vision areas shall be provided at all glazing area to make the glazing
air tight.
The periphery of the glazing shall be sealed both from inside and
outside with silicon weather sealant to make the glazings water / air
tight.
The gap between glazing & internal RCC slab to be filled with 1mm GI
tray filled with rock wool & covered with GI sheet cover & screwed
with ss screw to form smoke seal
All Screws, Bolts, Nuts and Washers used in the glazing shall be only
Stainless Steel
The Expansion joints between two mullions at every beam level
should be created by inserting 200 mm long Aluminium Expansion
Sleeve Tube and bolted with the main mullion member, and the
expansion joint gap should be minimum 10 mm. The Expansion joint
must be properly sealed all around with weather sealant to make it
water tight.
The item shall be inclusive of providing and fixing Insulated glass unit
with outer pane 6mm tempered glass + 12mm air gap hermetically
sealed and inner glass 6mm clear tempered glass. 2mm thick
Aluminum sheet/tube folded( for railings on corridor as per arch as
per drawings enclosed/ instruction of engineer in charge.
Extruded Pressure plate & Powder coated cover plate to be part of
glazing & included in rates( Both horrizontally & Vertically)
2mm thick(Z-shape or any shape approved by Architecht) powder
coated aluminum flashing at all along the junction of old & new
glazing or where ever required is included & part of Glazing only
All the corner or edge closing & for matching with existing Glazing
ACP/Aluminum sheet or tube included in items & part of glazing only.
15.1

15.1.1

15.1.2
15.2

WITH GLASS TYPE T1 (double)


Saint Gobain Planitherm White Light Transmission 75, U value1.77,
Shading coefficient0.62,
Openable panels (wit all accessories ,friction hinges,gasket, four
point locking system complete as per instruction of In-charge)
Fixed panels
Providing and fixing Spandrel panel made of tempered 6mm single
glass
WITH GLASS TYPE T2 (single)

15.2.1

8mm Saint Gobain single toughened glass with grey opaque backing
made of .8mm thick dark grey Powder coating GI sheet sheet of
insulation as per existing structural glazing.

15.3

Providing and fixing parapet panel made of 2 *6mm float glass


panels laminated with PVB film, color to be specified by the architect.
External sheet only to be as specified below, internal sheet to be
ordinary clear glass.
WITH GLASS TYPE T3 (laminated)

15.3.1

Glaverbel Sunlux T SS 520, Light Transmission 12, U value.2.72,


Shading coefficient 0.21

15.3.2

8mm+8mm clear laminated glass


TOTAL OF STRUCTURAL GLAZING
TOTAL OF STRUCTURAL GLAZING

G for New Class ROOMS

Sqm

Sqm

8,400
45.3936

48

441.218

463

400,372

6,900 3,196,624

Sqm

172

SPANDREL

6,400 1,100,736

Parapets

8,600 1,846,110

163.8

Sqm
RO

Sqm

Sqm

RO
204.44

215

6,543,842
6,543,842