Sie sind auf Seite 1von 545

Plant Design System (PDS)

Reference Data Manager (PD_Data)

Version 2011 (V12)


June 2011
DPDS3-PB-200034H

Copyright
Copyright 1984-2011 Intergraph Corporation. All Rights Reserved.
Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement;
contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret
law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph
Corporation.

U.S. Government Restricted Rights Legend


Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was
developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with
subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal
Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the
United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS
252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3.
Unpublished - rights reserved under the copyright laws of the United States.
Intergraph Corporation
P.O. Box 240000
Huntsville, AL 35813

Terms of Use
Use of this software product is subject to the End User License Agreement ("EULA") delivered with this software product unless the
licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license
for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this
software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee
permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and
delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or
redistribution.

Warranties and Liabilities


All warranties given by Intergraph Corporation about equipment or software are set forth in the EULA provided with the software or
applicable license for the software product signed by Intergraph Corporation, and nothing stated in, or implied by, this document or
its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in
this publication is accurate as of its publication date.
The information and the software discussed in this document are subject to change without notice and are subject to applicable
technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document.
The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms
of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by
Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS
TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.
Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data.
Users should verify for themselves that the data is accurate and suitable for their project work.

Trademarks
Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Convert, I-Export, I-Sketch, SmartMarine, IntelliShip, INtools,
ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of
Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered
trademarks of Microsoft Corporation. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of Oracle Corporation
and/or its affiliates. MicroStation is a registered trademark of Bentley Systems Inc, all rights reserved. Other brands and product
names are trademarks of their respective owners.

Contents
Preface PDS ............................................................................................................................................... 11
What's New in Reference Data Manager (PD_Data) ........................................................................... 12
Introduction ................................................................................................................................................ 13
Project Organization ............................................................................................................................. 13
Reference Data Overview ..................................................................................................................... 14
Piping Job Specification Introduction ............................................................................................. 15
Graphic Commodity Data Introduction ........................................................................................... 16
Material Description Data Introduction ........................................................................................... 16
Standard Note Library Introduction ................................................................................................ 17
Label Description Library Introduction ............................................................................................ 17
Piping Assembly Library Introduction ............................................................................................. 17
Reference Database Introduction ......................................................................................................... 17
Delivered Reference Data ..................................................................................................................... 18
Reference Data Setup .......................................................................................................................... 18
PDS Environment ...................................................................................................................................... 21
PD Shell ................................................................................................................................................ 21
PD_Shell Form Conventions .......................................................................................................... 24
Common Tools on the PD_Shell Forms ......................................................................................... 24
Batch Processes ............................................................................................................................. 29
Help ....................................................................................................................................................... 29
Reference Data Manager........................................................................................................................... 31
Data Security......................................................................................................................................... 32
Reference Data Archival ....................................................................................................................... 34
Reference Data Location .......................................................................................................................... 35
Default Project Control Data ................................................................................................................. 35
Reference Database Management Data .............................................................................................. 36
Piping Job Specification ........................................................................................................................... 41
Material Reference Database Structure ............................................................................................... 41
Neutral File Input ................................................................................................................................... 42
Piping Materials Class Data (201) .................................................................................................. 45
Piping Commodity Specification Data (202) ................................................................................... 48
Piping Specialty Specification Data (203) ...................................................................................... 56
Instrument Component Specification Data (204) ........................................................................... 58
Tap Properties Data (205) .............................................................................................................. 61
Piping Commodity Size-Dependent Material Data (211) ............................................................... 64
Piping Commodity Implied Material Data (212) .............................................................................. 66
Component Insulation Exclusion Data (231) .................................................................................. 69
Flange Insulation Exclusion Data (232).......................................................................................... 71
Piping Construction Tolerance Exclusion Data (233) ..................................................................... 73
Spec Writer ........................................................................................................................................... 74

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
Features ......................................................................................................................................... 75
RDB Options File ............................................................................................................................ 76
Piping Materials Class Data Command.......................................................................................... 84
Piping Commodity Data Command ................................................................................................ 87
Piping Specialty Data Command .................................................................................................... 96
Instrument Data Command ............................................................................................................ 99
Tap Properties Data Command .................................................................................................... 102
Commodity Implied Data Command ............................................................................................ 104
Table Checker .............................................................................................................................. 107
Piping Job Specification Manager....................................................................................................... 107
Load, Replace, or Replace Commodity Subset Options .............................................................. 110
Delete Option ................................................................................................................................ 112
Report Option ............................................................................................................................... 112
Piping Job Spec Report Manager ....................................................................................................... 114
Using the Report Commands ....................................................................................................... 114
Report Format Form ..................................................................................................................... 116
Report Discrimination Data Form ................................................................................................. 119
Report Form ................................................................................................................................. 125
Report Management Defaults Form ............................................................................................. 133
Piping Job Specification Tables ............................................................................................................ 135
PJS Tables and Functions .................................................................................................................. 135
Temperature and Pressure Service Limits Table ......................................................................... 136
Nominal Piping Diameter Table .................................................................................................... 137
Thickness Data Tables ................................................................................................................. 140
Materials Data Table .................................................................................................................... 142
Branch Insertion Tables................................................................................................................ 145
Gasket Separation Table .............................................................................................................. 149
Fluid Code Table .......................................................................................................................... 151
Wall Thickness and Branch Reinforcement Equations ....................................................................... 152
RDB Tables ......................................................................................................................................... 155
Commodity Item Name Table (G02) ............................................................................................ 156
Bend Deflection Table (G04) ........................................................................................................ 158
Segment Pipe Run Length Threshold Table (G06) ...................................................................... 159
Pipe Length Threshold Table (G07) ............................................................................................. 160
Preferred Bolt Length Table (G11) ............................................................................................... 161
Weld Type Table .......................................................................................................................... 164
Bolt Commodity Code Table ........................................................................................................ 166
Weld Clearance Table .................................................................................................................. 167
Weld Graphics Dimensions Table ................................................................................................ 168
Gasket Diameter Table................................................................................................................. 169
Field Fit Length Table ................................................................................................................... 170
Component Mirror Table............................................................................................................... 170
Operator Mirror Table ................................................................................................................... 171
Default End Preparation Table ..................................................................................................... 172
MTO Tables and Functions .......................................................................................................... 172
Piping Job Specification Tables Command ........................................................................................ 173
Create Library ............................................................................................................................... 174
Compress Library ......................................................................................................................... 174
Unapproved ==> Approved .......................................................................................................... 174
Create/Interactive Spec Tables .................................................................................................... 175
Create/Batch Spec Tables ........................................................................................................... 175
Revise Spec Tables ...................................................................................................................... 176

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
Delete Spec Tables ...................................................................................................................... 177
Report on Spec Tables ................................................................................................................. 178
List Spec Tables ........................................................................................................................... 180
Extract Spec Tables ..................................................................................................................... 180
Graphic Commodity Data ....................................................................................................................... 183
Graphic Commodity Library ................................................................................................................ 183
Symbol Processors ....................................................................................................................... 186
Sub-Symbol Processor ................................................................................................................. 187
Physical Data Definitions .............................................................................................................. 187
Parametric Shape Definitions ....................................................................................................... 192
Physical Data Tables .......................................................................................................................... 194
Data Retrieval from the Physical Data Library ............................................................................. 195
Example of Physical Data Look-Up .............................................................................................. 195
Notes for Graphic Commodity Data .................................................................................................... 196
Connect Point Data ...................................................................................................................... 196
Bends and Branches .................................................................................................................... 198
Bolts, Gaskets, and Flanges ........................................................................................................ 198
Pipe, Tubing, and Hose ................................................................................................................ 199
Graphic Commodity Library Manager ................................................................................................. 199
Create Library ............................................................................................................................... 200
Compress ..................................................................................................................................... 200
Unapproved ==> Approved .......................................................................................................... 200
Create/Interactive Graphic Commodity Data ............................................................................... 201
Create/Batch Graphic Commodity Data ....................................................................................... 201
Revise Graphic Commodity Data ................................................................................................. 202
Delete Graphic Commodity Data .................................................................................................. 204
Report Graphic Commodity Data ................................................................................................. 205
List Graphic Commodity Data ...................................................................................................... 205
Extract Graphic Commodity Data ................................................................................................. 206
Graphic Commodity Modules List ................................................................................................ 207
Physical Data Library Manager ........................................................................................................... 208
Create Library ............................................................................................................................... 209
Compress ..................................................................................................................................... 210
Unapproved to Approved ............................................................................................................. 210
Create/Interactive Physical Commodity Data ............................................................................... 210
Create/Batch Physical Commodity Data ...................................................................................... 211
Revise Physical Commodity Data ................................................................................................ 212
Delete Physical Commodity Data ................................................................................................. 213
Report Physical Commodity Data ................................................................................................ 214
List Physical Commodity Data ...................................................................................................... 216
Extract Physical Commodity Data ................................................................................................ 216
Table Formats and Naming Conventions ............................................................................................. 219
Table Conventions .............................................................................................................................. 219
Abbreviations ................................................................................................................................ 227
Table Requirements ............................................................................................................................ 228
Tables Required for Piping Components ..................................................................................... 228
Tables Required for Instrument Components .............................................................................. 231
Generic Tables .................................................................................................................................... 232
Variables for Generic Tables ........................................................................................................ 232
Generic Table for Bolted Ends (G10) ........................................................................................... 236

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
Generic Table for Studs used in Bolted Connections (G12) ........................................................ 237
Generic Table for Studs in Bolted Connections w/ Term Type (G12T) ........................................ 239
Generic Table for Male Ends (G20) ............................................................................................. 241
Generic Table for Female Ends (G30) ......................................................................................... 243
Generic Table for Weight and Thickness Data, Male Ends (G50) ............................................... 244
Piping Component Tables ................................................................................................................... 245
Variables for Specific Tables ........................................................................................................ 247
Piping Component Table for GCP Data (P11A, P15A) ................................................................ 251
Piping Component Table GCP Overflow Data (P11B, P15B) ...................................................... 252
Piping Component Table Green and Red CP Data (P21A, P25A, P26A, P27A,
P28A, P29A) ................................................................................................................................. 253
Piping Component Table Green and Red CP Overflow Data
(P21B,P25B,P26B,P27B,P28B) ................................................................................................... 255
Piping Component Table for Operators and Actuators (P31A) .................................................... 256
Piping Component Table for Operators and Actuators, Overflow Data (P31B) ........................... 257
Piping Component Table for Empty Weight based on GCP Data (P51,P52,P59) ....................... 258
Piping Component Table For Empty Weight of Valves (P60A) .................................................... 260
Piping Component Table For Empty Weight of Valves, Overflow Data (P60B) ........................... 261
Piping Component Table for Empty Weight based on GCP and RCP Data
(P61,P62,P63,P64,P65) ............................................................................................................... 263
Piping Component Tables for Specialty Components .................................................................. 264
Instrument Component Tables ............................................................................................................ 264
Instrument Body (I80 and P80) .................................................................................................... 264
Instrument Operator (I81 and P81) .............................................................................................. 266
Material Description Data ....................................................................................................................... 269
Material Data in the Material Reference Database ............................................................................. 272
Short Material Description Library....................................................................................................... 273
Long Material Description Library ....................................................................................................... 279
Specialty Material Description Library ................................................................................................ 281
Material Description Library Manager ................................................................................................. 282
Create Library ............................................................................................................................... 284
Unapproved ==> Approved .......................................................................................................... 285
Load/Revise Interactive ................................................................................................................ 285
Load/Revise Batch ....................................................................................................................... 286
Replace Interactive ....................................................................................................................... 286
Replace Batch .............................................................................................................................. 287
Report Option ............................................................................................................................... 288
Table Checker .......................................................................................................................................... 291
Table Checker Form ........................................................................................................................... 293
Using the Report Commands ....................................................................................................... 294
Report Format Form ..................................................................................................................... 295
Discrimination Data Form ............................................................................................................. 298
Report Form ................................................................................................................................. 303
Report Management Defaults Form ............................................................................................. 311
Sample Table Checker Output............................................................................................................ 312
Pipe Support Tutorial Definition Manager ............................................................................................ 323
Support Tutorial Definition Manager ................................................................................................... 323
Create Library ............................................................................................................................... 324

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
Compress ..................................................................................................................................... 324
Unapproved ==> Approved .......................................................................................................... 324
Create Data .................................................................................................................................. 324
Revise Data .................................................................................................................................. 325
Delete Data ................................................................................................................................... 326
Report Data .................................................................................................................................. 327
List Data ....................................................................................................................................... 328
Extract Data .................................................................................................................................. 329
Library List .................................................................................................................................... 330
Standard Note Library ............................................................................................................................. 331
Standard Note Library Manager.......................................................................................................... 334
Create Library ..................................................................................................................................... 335
Compress ............................................................................................................................................ 335
Unapproved ==> Approved ................................................................................................................. 335
Create Standard Note Type ................................................................................................................ 336
Revise Standard Note Type ................................................................................................................ 336
Report Standard Note Library Contents ............................................................................................. 338
List Standard Note Data ...................................................................................................................... 339
Delete Standard Note Data ................................................................................................................. 339
Extract Standard Note Type ................................................................................................................ 340
Load Database .................................................................................................................................... 341
Standard Note Types List ................................................................................................................... 342
Label Description Library ....................................................................................................................... 343
Label Types ......................................................................................................................................... 343
Displayable Attribute Labels ......................................................................................................... 344
Alphanumeric Labels .................................................................................................................... 344
Displayable Attribute Message ..................................................................................................... 344
Commodity Code Attribute Message ............................................................................................ 345
Isometric Drawing Labels ............................................................................................................. 345
Report Labels ............................................................................................................................... 345
Clash Management Labels ........................................................................................................... 345
Label Description Library Manager ..................................................................................................... 347
Create Library ............................................................................................................................... 347
Compress Library ......................................................................................................................... 348
Unapproved ==> Approved .......................................................................................................... 348
Create Label Data ........................................................................................................................ 348
Revise Label Data ........................................................................................................................ 358
Delete Label Data ......................................................................................................................... 361
Report Label Data ........................................................................................................................ 361
Label Library Merger ........................................................................................................................... 366
Label Library Merger Interface ..................................................................................................... 367
Label Library Merge Workflow ...................................................................................................... 370
Piping Assembly Library ........................................................................................................................ 373
Piping Assembly Language ................................................................................................................ 373
Placing Taps in Assemblies ......................................................................................................... 383
Sample Piping Assembly Files ..................................................................................................... 384
Piping Assembly Library Manager ...................................................................................................... 386
Create Library ............................................................................................................................... 388

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
Compress ..................................................................................................................................... 388
Unapproved ==> Approved .......................................................................................................... 388
Create/Interactive Piping Assembly Data ..................................................................................... 388
Create/Batch Assembly Data ....................................................................................................... 389
Revise Piping Assembly Data ...................................................................................................... 389
Delete Piping Assembly Data ....................................................................................................... 391
Report Assembly Data.................................................................................................................. 392
List Assembly Data ....................................................................................................................... 393
Extract Assembly Data ................................................................................................................. 394
Reference Database Revision Manager ................................................................................................ 395
Reference Data Conflict Report .......................................................................................................... 397
Table Change Report .......................................................................................................................... 401
Reference Data Impact Report ........................................................................................................... 407
Proposed RDB Changes Report ......................................................................................................... 410
MicroStation V7 Checker ........................................................................................................................ 415
Verify RDB Library................................................................................................................................... 417
Appendix: Reference Data Manager Error Messages .......................................................................... 421
Appendix: Codelists ................................................................................................................................ 423
CL31, Object Types for Orthographic Drawings (40).......................................................................... 425
CL35, Approval Status (10) ................................................................................................................. 427
CL36, Structural Approval Status (15) ................................................................................................ 427
CL37, HVAC Approval Status (10)...................................................................................................... 427
CL50, Hold Status (10) ....................................................................................................................... 427
CL69, Equipment Divisions/Form Code (99) ...................................................................................... 428
CL125, Fluid Code/Connector Type (999) .......................................................................................... 428
CL130, Construction Status (15)......................................................................................................... 432
CL145, Materials Grade (4500) .......................................................................................................... 432
CL148, Piping Materials Class Description (31999) ........................................................................... 462
CL160, Responsibility (25) .................................................................................................................. 470
CL180, Fabrication Category (99)....................................................................................................... 470
CL190, Coating Requirements (99) .................................................................................................... 471
CL200, Heat Tracing Requirements (10) ............................................................................................ 471
CL210, Heat Tracing Media (60) ......................................................................................................... 472
CL220, Insulation Purpose (40) .......................................................................................................... 472
CL230, Cleaning Requirements (99) .................................................................................................. 473
CL330, CP Type/Termination/Preparation (999) ................................................................................ 473
CL332, Schedule / Thickness Override .............................................................................................. 477
CL340, Safety Classification (99)........................................................................................................ 478
CL360, Stress Analysis Requirements (15) ........................................................................................ 478
CL365, Reporting Requirements (25) ................................................................................................. 479
CL366, Requirement to Reconstruct (10) ........................................................................................... 479
CL380, Piping Component Type (2500) ............................................................................................. 479
CL390, Action (40) .............................................................................................................................. 486
CL400, Option (999) ........................................................................................................................... 487
CL420, Piping Component Type/Source (25) ..................................................................................... 494
CL425, Piping/Tubing Type (25) ......................................................................................................... 494
CL430, Instrument Component Type/Source (25) .............................................................................. 494

Plant Design System (PDS) Reference Data Manager (PD_Data)

Contents
CL499, Piping Notes (999) .................................................................................................................. 495
CL530, Accessory/Item Type (125) .................................................................................................... 497
CL550, Operator Actuator Type (200) ................................................................................................ 497
CL570, Design Standard (200) ........................................................................................................... 498
CL572, Wall Thickness Equation ........................................................................................................ 499
CL575, Geometry Standard (31999)................................................................................................... 499
CL576, Table Suffix/End Standard - Green (999) ............................................................................... 513
CL577, Table Suffix/End Standard - Red (999) .................................................................................. 517
CL578, Weight Code (399) ................................................................................................................. 522
CL990, Types of Piping Commodity Data Forms ............................................................................... 523
CL999, Standard Note Title (2000) ..................................................................................................... 524
CL1010, Area Units (25) ..................................................................................................................... 526
CL1028, Mass Units (40) .................................................................................................................... 527
CL1056, Temperature Units (15) ........................................................................................................ 527
CL1064, Pressure Units (40) .............................................................................................................. 527
CL1074, Density Units (35) ................................................................................................................. 528
CL1100, Weld Type (100) ................................................................................................................... 529
CL1162, Force Units (40) .................................................................................................................... 529
CL1201, Drawing Scale (540) ............................................................................................................. 530
CL1202, Drawing Size (199) ............................................................................................................... 530
CL1203, Interference Manager Approval Status (99) ......................................................................... 530
CL1204, Interference Clash Type (10) ............................................................................................... 531
CL1205, Interference Manager Action (10) ........................................................................................ 533
CL1207, Interference Manager Approval Method(10) ........................................................................ 533
CL1208, Clash Checking Option......................................................................................................... 533
CL1209, Clash Checking Volume Filter Option .................................................................................. 534
CL1310, Report Source (99) ............................................................................................................... 534
CL1312, Report Type (999) ................................................................................................................ 534
CL1410, Design Review Type (10) ..................................................................................................... 534
CL1605, Model Status ........................................................................................................................ 535
CL1610, Force Units for FrameWorks Plus (40) ................................................................................. 535
CL1620, Drawing View Directions (7) ................................................................................................. 535
CL1630, Drawing View Composition Status (4) .................................................................................. 535
CL1710, Document Source (99) ......................................................................................................... 535
CL1720, Document Type (999) ........................................................................................................... 536
CL1900, Isometric Drawing Type ........................................................................................................ 539
CL2000, PD_Draw Document Type (999) .......................................................................................... 539
Index ......................................................................................................................................................... 541

Plant Design System (PDS) Reference Data Manager (PD_Data)

Preface PDS
This document provides command reference information and procedural instructions for the Plant
Design System (PDS) Reference Data Manager (PD_Data) task.

List of PDS Documentation

DPDS3-PB-200003 - DesignReview Integrator (PD_Review) Reference Guide


DPDS3-PB-200004 - Drawing Manager (PD_Draw) User's Guide
DPDS3-PB-200005 - EE Raceway Modeling Reference Guide
DPDS3-PB-200006 - Interference Checker/Manager (PD_Clash) User's Guide
DPDS3-PB-200010 - PDS 3D Theory User's Guide
DPDS3-PB-200013 - PDS EDEN Interface Reference Guide Volume I : Piping
DPDS3-PB-200015 - PDS Equipment Modeling (PD_EQP) User's Guide
DPDS3-PB-200017 - PDS ISOGEN Reference Guide, Vol. 1
DPDS3-PB-200022 - PDS Piping Component Data Reference Guide
DPDS3-PB-200023 - PDS Project Setup Technical Reference
DPDS3-PB-200025 - PDS Stress Analysis Interface (PD_Stress) User's Guide
DPDS3-PB-200026 - Pipe Supports Modeler Reference Guide
DPDS3-PB-200028 - Piping Design Graphics (PD_Design) Reference Guide
DPDS3-PB-200030 - Project Administrator (PD_Project) Reference Guide
DPDS3-PB-200033 - Project Engineer HVAC (PE-HVAC) Reference Guide
DPDS3-PB-200034 - Reference Data Manager (PD_Data) Reference Guide
DPDS3-PB-200035 - Report Manager (PD_Report) User's Guide
DPDS3-PB-200041 - PDS EDEN Interface Reference Guide Volume 2 : Equipment
DPDS3-PB-200042 - PDS EDEN Interface Reference Guide Volume 3 : Pipe Supports
DPDS3-PE-200016 - PDS Express Project Creation Quick Start Guide
DPDS3-PE-200052 - PDS Ortho Draw User's Guide
DPDS3-PE-200029 - Piping Model Builder (PD_Model) Reference Guide
DPDS3-PE-200031 - Project Engineer HVAC Getting Started Guide
DPDS3-PE-200032 - Project Engineer HVAC Overview
DPDS3-PE-200045 - PDS Label Library Merger Utility
DPDS3-PE-200047 - PDS Reference Data Auditing Tool
DPDS3-PE-200048 - Pipe Supports Explorer Utility
DPDS3-PE-200050 - Batch Services Quick Start Guide
DPDS3-PE-200051 - Batch Services User's Guide

Plant Design System (PDS) Reference Data Manager (PD_Data)

11

Preface PDS

What's New in Reference Data Manager (PD_Data)


The following changes have been made to Reference Data Manager (PD_Data):
Version 2011 (V12)
You can now check for MicroStation V8 design files in Reference Data Manager form. For
more information see MicroStation V7 Checker (on page 415). (P3 PB:120457)
Additional symbol processors are added. (CR PB:8044)
Added branch table to incorperate ASME code to be in sync with SP3D. (CR PB:99694)

12

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 1

Introduction
Welcome to the Reference Data Manager (PD_Data) module of the Plant Design System of
software. Intergraph's plant design software can be used to design any type of plant from
petrochemical plants, offshore platforms, chemical and pharmaceutical plants, consumer
products (food, beverages, cosmetics, soap, paper, and so forth), to power plants, waste water
treatment plants, and cogeneration facilities.
Specifically, the Plant Design System (PDS) integrates many discipline-specific software
modules; these modules automate the many phases of a plant design project. Reference Data
Manager (PD_Data) is one of these modules.
In PDS, placement of piping components is driven by the specification. The PDS reference data
provides the selection criteria for the piping commodity items that are found in the piping job
specification and the piping commodity libraries that are delivered with the product. This data is
contained in the reference database (RDB) and can be used by other projects.
The Reference Data Manager (PD_Data) is specifically designed to define and modify the
reference data for the PDS 3D modules. This reference data ensures consistency in the
definition of piping specifications and commodity libraries. It is used to control and standardize
the PDS 3D modules to reflect company practices and standards.

Project Organization
Since a process plant such as a refinery can be extremely large, PDS uses the following
organization to break the plant into smaller pieces that can be handled more easily.
A project is a convenient grouping of either all or part of the items that constitute a plant. The
project is the fundamental structure for working in PDS. Each project contains all the information
required to work in a PDS task.
The Project Administrator controls the creation and modification of Piping projects. Each Piping
project consists of a project control database, project design database, piping and equipment
models, reference models (structural, HVAC, and electrical raceway), a set of drawings, and a
collection of reference data. The reference data may be specific to one project or shared by more
than one project.
A project and all of its accompanying files must be defined with the Project Administrator before
you can use any of the other 3D PDS modules. Refer to the Project Administrator Reference
Guide for more information on setting up a project.

Plant Design System (PDS) Reference Data Manager (PD_Data)

13

Introduction

Reference Data Overview


The Reference Data Manager (PD_Data) enables you to define and modify the reference data
for the PDS 3D modules. This reference data is used to ensure consistency in the definition of
piping specifications and commodity libraries. It enables you to control and standardize the PDS
3D tasks. You can also modify the reference data to reflect company practices and standards.
The Reference Data for PDS 3D is composed of the following basic components:

Spec/Material Database

Piping Materials Class Data (201) (on page 45)


Piping Commodity Specification Data (202) (on page 48)
Piping Specialty Specification Data (203) (on page 56)
Instrument Component Specification Data (204) (on page 58)
Tap Properties Data (205) (on page 61)
Piping Commodity Size-Dependent Material Data (211) (on page 64)
Piping Commodity Implied Material Data (212) (on page 66)
Component Insulation Exclusion Data (231) (on page 69)
Flange Insulation Exclusion Data (232) (on page 71)

Practice Specific Reference Data

Physical Data Tables (on page 194)


Piping Job Specification Tables (on page 135)
Short Material Description Library (on page 273)
Long Material Description Library (on page 279)
Specialty Material Description Library (on page 281)

Practice Independent Reference Data


Graphic Commodity Data (on page 183)
Standard Note Library (on page 331)
Label Description Library (on page 343)
Piping Assembly Library (on page 373)
The Reference Data Manager supports both approved and unapproved reference data for a
project. The Project Control Database contains complete file management data for both an
approved and unapproved version of each type of reference data such as the Piping Job
Specification or the Graphic Commodity Library. This allows revisions to take place in unapproved
files while other processes read the approved files. Once the information in the unapproved files
has been verified, it can be posted to the approved reference data files.

14

Plant Design System (PDS) Reference Data Manager (PD_Data)

Introduction
The following figure illustrates the various pieces of reference data required to place a 6" gate
valve in a piping model and report on the placed component. It depicts how the various parts that
make up PDS work together. Whenever possible, this placement example will be used throughout
the rest of this document. For example, the discussion of the physical dimension tables will use
the tables called to place the gate valve as examples.

See Also
Project Organization (on page 13)
Reference Database Introduction (on page 17)
Delivered Reference Data (on page 18)
Reference Data Setup (on page 18)

Piping Job Specification Introduction


The Piping Job Specification (PJS) provides selection criteria for piping commodity items, piping
specialty items, and instruments. The information for the Piping Job Specification is contained in
the following files:
Specification/Material Reference Database - database containing the definitions for piping
materials classes, commodity items, specialty items, and tap properties tables.
Spec Table Library - library containing the specification tables referenced in the PJS.
The information in the Specification/Material Reference database and Spec Table Library tables is
also delivered in the form of neutral files which you can extract and modify.

Plant Design System (PDS) Reference Data Manager (PD_Data)

15

Introduction
The Piping Job Specification Manager enables you to create or revise the specification data in the
Material Reference Database. You can use the interactive (forms-driven) specification writer or
define/revise the data using ASCII neutral files.
The Piping Job Spec Tables command enables you to create, revise, and delete tables in the
Spec Table Library.

Graphic Commodity Data Introduction


The graphic commodity data is used to define commodity items, specialty items, and instruments.
The Graphic Commodity Library contains the parametric symbol definitions required to place
piping and instrument components in a 3D model. When you place a component the system
uses the Piping Job Specification to select the appropriate component from the parametric symbol
definition library which then accesses the component dimensional data.
The graphic commodity data is contained in the following object libraries:
Graphic Commodity Library - contains the parametric definitions for the commodity items.
Physical Dimension Libraries - contains dimension data for the commodity items. (A different
Physical Dimension Library is required for each type of practice such as U.S., DIN, or British
Standard).
Spec Table Library - contains the specification tables referenced in the PJS.
The parametric descriptions and dimension tables are also delivered in the form of text libraries
which you can extract and modify using the Graphic Commodity Library Manager and Physical
Data Library Manager.

Material Description Data Introduction


The Material Description Data is accessed for:
Material Take-off (MTO) reporting from the Design Database
Other miscellaneous reporting
Interfaces to the material control system
Stress analysis
Isometric drawing extraction.
The Material Description Data consists of the commodity item data which is not stored in the
Design Database, which is not required for the creation of graphic symbologies, and which is not
part of the geometric data. This data is contained in the following files:
Material Data in the Specification/Material Database - database tables containing definitions
for commodity items, criteria for implied material, and weld data.
Short Material Description Library - contains the short material descriptions for commodity
items and taps.
Long Material Description Library - contains the long material descriptions for commodity
items.
Specialty Material Description Library - contains the material descriptions for specialty items.
The material descriptions are also delivered in the form of neutral files which you can modify and
post to the libraries.
The Material Description Library Manager enables you to create, revise, and delete data in the
Material Description Libraries. You can use the Piping Job Specification Manager to load the
material data tables in the Specification/Material Database.

16

Plant Design System (PDS) Reference Data Manager (PD_Data)

Introduction

Standard Note Library Introduction


The text for code-listed attributes and standard notes is stored in the Standard Note Library. All
attributes identified as code-listed are actually stored as integer values. The code list text
associated with the integer is stored in the Standard Note Library. Information in the Standard
Note Library is identified by note number and note type. Output from the library consists of
free-format text which forms the standard note.

Label Description Library Introduction


The Label Description Library contains the definitions for the following label types used in PDS 3D:
Orthographic drawing view specific labels
Orthographic drawing view identification labels
Orthographic drawing - user input
Displayable attribute messages
Commodity code attribute messages
Isometric drawing labels
Report labels
Clash management labels
These labels are intelligent graphics with links to the material database.
The Label Description Library Manager enables you to define the graphic parameters for a
label (such as level, line weight, and color code) and to define the format of the label (what
information comprises the label).

Piping Assembly Library Introduction


The Piping Assembly Library contains the piping assembly definitions which define the
parameters necessary to place a piping assembly (group of components) automatically in the
model.
A Piping Assembly object library and text library which contain the definitions for basic assemblies
are included in the product delivery.

Reference Database Introduction


A database is a collection of formatted data which conforms to a set of pre-defined rules. The
Specification/Material Reference Database is composed of a set of tables (entities) which
represent categories of data. A table is a defined set of attributes which describe an item, such as
the Piping Commodity Data table.
An attribute is a single type of information to be stored about an item, such as nominal diameter or
end preparation. Each attribute has a column number in the database table and a name which
describes the piece of information to be stored. The actual information stored in the database is
referred to as the attribute value. This value is a fixed data type; it can be either numeric,
alphanumeric, or code-listed.
numeric data types can be either real (decimal) or integer. These attributes are used for
quantitative values such as pressure or temperature.
alphanumeric data types (also called character) are used for textual information such as
component names or descriptions.
code-listed data types are special integer values which help standardize and speed up data
entry. A code list is a set of acceptable values for a particular attribute which can be referred to

Plant Design System (PDS) Reference Data Manager (PD_Data)

17

Introduction
by an index number. A code-listed attribute is an attribute whose value is defined using one of
the selections from a particular code list set.

Delivered Reference Data


The following reference data is delivered in the reference database products for the
corresponding practices (such as RDUSRDB or RDDINRDB).
File Description

Library Object

Library Text

Physical Dimension Table Library us_pcdim.l

us_pcdim.l.t

Piping Job Specification Table


Library

us_pjstb.l.t

us_pjstb.l

Short Material Description Library us_shbom.l

Long Material Description Library

us_lgbom.l

Specialty Material Description


us_spbom.l
Library
For the DIN RDB substitute din_ for us_ in the listed library file names.
The following reference data, which is not unique to any specific practice, is delivered in the PD
Shell product in the \win32app\ingr\pdshell\lib directory.
File Description

Library Object

Library Text

Graphic Commodity Library

pip_gcom.l

pip_gcom.l.t

Piping Assembly Library

assembly.l

assembly.l.t

Label Description Library

labels.l

Standard Note Library

std_note.l

std_note.l.t

Reference Data Setup


A project and all of its accompanying files must be defined with the Project Administrator before
you can use the Reference Data Manager. Refer to the Project Administrator Reference Guide
for information on:
Loading PDS 3D products.
Editing the control script to identify the location of the project data.
Setting up a project and creating the associated database schemas.
Accessing the PDS 3D products remotely using NFS.
In addition to the information specified in the Project Administrator Reference Guide, you should
complete the following steps before using the Reference Data Manager.
Load the appropriate Reference Data product (such as RDUSRDB for U.S. Practice or
RDDINRDB for DIN Practice).
Edit the pds.cmd file to identify the text editor to be used when revising reference data through
the Reference Data Manager forms. You can specify any text editor that has been loaded
on the workstation. The default setting for Windows systems is Notepad.
$ENV {'PD_EDITOR'} = '<absolute path to preferred editor executable>';

18

Plant Design System (PDS) Reference Data Manager (PD_Data)

Introduction

Edit the pds.cmd file to define PDS_COMMIT_INTERVAL to control the commit interval for
use in loading specification data into the Material Reference Database. This has the same
impact as adjusting the -c option in a risload command line. The default commit value is 25.
Increasing this variable may improve performance.
Identify the location of the Reference Data files as described in Reference Data Location (on
page 35).

Plant Design System (PDS) Reference Data Manager (PD_Data)

19

SECTION 2

PDS Environment
The PDS 3D software supports a variety of applications. All the supported applications use a
common interface that is controlled by the PD Shell program. This ensures consistency across
applications and minimizes the amount of time required to learn the product.
The PDS 3D modules provide a simple user interface through extensive use of forms. The
modules also provide an on-line Help capability for easy access to information while working in the
product.
The PD_Shell Environment and all batch jobs in the PDS 3D products interface to Intergraph's
Network Licensing System.

See Also
PD Shell (on page 21)
Help (on page 29)

PD Shell
The PD Shell program provides access to the various functions that are associated with the PDS
3D Modules. You can access the Plant Design System Environment form by clicking Start > All
Programs > PD_Shell > PD_Shell. This executes a control script that defines all of the
environment variables that are needed to run the product, and it identifies the location of the
product files. These files can be located on the workstation or a server on the network. See
pds.cmd for more information on this file. The script also activates the Plant Design System
Environment form.

Plant Design System (PDS) Reference Data Manager (PD_Data)

21

PDS Environment
To make colors easier to read on flat screens and projectors, a zip file with modified color for PDS
forms is delivered as alternatecolorfb.zip.

This form identifies the active project(s) and provides access to all the PDS functions.
Schematics Environment Provides access to the PDS 2D modules that are used to create
and modify piping and instrumentation diagrams, process flow diagrams, and instrumentation
database records.
Equipment Modeling Provides access to the Equipment Modeling module, which provides an
interactive graphics environment that is used to create and revise equipment model graphics and
database information.
FrameWorks Environment Provides access to the FrameWorks module, which provides an
environment that is used to create and revise structural models, create and revise structural
drawings, and propagate structural models.
Piping Designer Activates an interactive command environment that is used to create piping
and in-line instrumentation in the model; revise existing model graphics and database information;
and verify the integrity of the data in the model.
Electrical Raceway Environment Provides access to the Electrical Raceway module, which
provides an interactive environment that is used to create and revise raceway models and access
raceway utilities.
Piping Design Data Manager Provides access to a set of options that are used to verify the
integrity of the graphic and database information that is associated with a model.
Piping Model Builder Enables you to create piping graphics from a nongraphics environment.
This module is used with PD_Design to create an accurate 3D model of the piping network.
Pipe Support Designer Activates an interactive command environment that is used to create
pipe supports in the model, and revise existing pipe support model graphics and database
information.

22

Plant Design System (PDS) Reference Data Manager (PD_Data)

PDS Environment
Pipe Stress Analysis Activates a set of forms that are used to extract information from piping
models for input to third-party pipe stress analysis products.
Interference Manager Activates a set of forms that are used to check for interferences among
project models and to control approved interferences.
Isometric Drawing Manager Activates a set of forms that are used to extract isometric
drawings from piping models and to review or plot the created isometric drawings.
Drawing Manager Activates a set of forms that are used to create and manipulate drawings
and drawing views; provide access to the interactive graphics environment for drawings; and
provide access to a plot manager and vector hiddenline manager.
DesignReview Integrator Activates a set of forms that are used to extract information to form
label files for use in SmartPlant Review and to review data from a SmartPlant Review session.
Report Manager Activates a set of forms that are used to create and revise report format files
and report on information in a project including Material Take-Off reports.
Project Administrator Provides access to a set of forms that are used to create a project,
create and revise project files, define project seed data, and control the project.
Reference Data Manager Provides access to a set of forms that are used to control the
reference data for a project including Piping Job Specification data, Graphic Commodity Data,
Alphanumeric Commodity Data, Standard Note Library, Label Description Library, and Piping
Assembly Library.
User ID Used for access control. This field also sets the Review User ID for use in the
Interference Manager module.
If access control has been defined, you must key in a valid user ID as defined by your system
manager to gain access to the projects. Refer to Access Control Manager, page 467, for more
information on using access control.
If access control has not been defined, no entry is required for this field.
Password Key in the password for the specified user ID.
Project List Field Displays the defined projects for the network and allows you to select the
active project. The system lists all the defined PDS projects (2D-only, 3D-only, and 2D & 3D). An
error is displayed if you select an option that is incompatible with the active project. For example,
if the active project is a 2D-only project, you cannot access the Interference Manager module.
If access control has been defined, only those projects for which you have some level of access
are displayed.
Message Area Displays prompts and messages that are associated with the active process.
Error messages are displayed in red.

Plant Design System (PDS) Reference Data Manager (PD_Data)

23

PDS Environment

PD_Shell Form Conventions


The following conventions describe how to respond to the various buttons, lists, and prompts that
make up the environments. The display size of forms and dialog boxes in the non-Microstation
graphics environment are independent of the size of the workstation's display system. Most forms
contain the same basic features: buttons, fields, text, and other gadgets. In general, anything
you find on a form is called a gadget.
You move through the PD_Shell forms by selecting function buttons or other gadgets from the
form. Select means to place the screen cursor (which appears as an arrow) on top of a screen
gadget and press <D>.
For most of the forms with scrolling lists, you can double-click on a row to select and accept the
data in that row. This performs the same action as selecting a row (which highlights) and then
selecting the Accept button.
You use the select action to select functions, access other forms, activate data fields, toggle
buttons, select from lists, scroll through data displayed on the screen, and so on.
The following summarizes other basic actions you use in the environments:
Enter - When keying in any data in a key-in field, press the <ENTER> or <Tab> key for the data to
be entered into the system. You can also press <ENTER> or <Tab> to move through a set of
key-in fields.
Delete - If you make a mistake while keying in text, press the <Delete> key to erase character(s)
to the left of the cursor.

Common Tools on the PD_Shell Forms


There are many gadgets in the environments that are common to most or all of the forms. The
following describes these tools.

Standard Commands
The PD_Shell forms have a set of standard buttons in the upper right corner of most of the form
windows. The available commands vary from form to form depending on the type of operation.
The Help button activates on-line Help for the
active form. Help remains active until you delete
the Help window.
The Shell button exits the active form and
returns control to the base manager that is
associated with the active form. For most
forms this returns to the Plant Design System
Environment form.
The Top button exits the active form and returns
control to the top form of the active branch.
The Cancel button cancels or exits from the
active form. Control returns to the immediately
preceding form in the hierarchy.
The Accept button accepts a selection or
operation. Depending on the active form or
option, the active form remains active so that
you can repeat a similar operation or control

24

Plant Design System (PDS) Reference Data Manager (PD_Data)

PDS Environment
returns to the preceding form.
The Restart button clears any key-in fields on
the form that have values you can modify.
Scrolling List
Some screen menus have a scrolling list of
projects or applications. You need to scroll a list
only if more options are available than can be
displayed in the window. To scroll a list, select
the arrow buttons on the side of the list. The
list scrolls up or down depending on which
arrow you select.
The scrolling list has an arrow pointing up
and an arrow pointing down. These arrows
scroll lists line by line. There is a button that
slides between these two arrows to indicate
your position on the list. To page through the
list, select the space above or below the sliding
button. The list pages up or down accordingly.
You can also select the slider and, while
pressing <D>, slide the button up or down the
bar. The items scroll through the window as
you move the button. The size and position of
the button on the scroll bar is an indication of the
number of lines and the relative position within
the list.
All commands that display a list of design areas
or models order the list alphanumerically by the
design area number or model number in
ascending order.
In some forms with scrolling lists, you can
double-click on a row to select and accept the
data in that row. This performs the same
action as selecting a row (which highlights) and
then selecting the Accept button.
Key-in Fields
Screens that accept keyboard input have key-in
fields. These fields are box-shaped and dark
gray. You can select a key-in field and key in a
new value. A bar cursor appears in the active
key-in field. Key in your input, and press
<Return>. To change a field, re-select the field
and key in the new information. Key-in fields
have a maximum number of characters
depending on the item that is being defined.
If you select a key-in field for a code-listed
attribute, the system activates a form that lists
the code list values for the selected field.

Plant Design System (PDS) Reference Data Manager (PD_Data)

25

PDS Environment
MicroStation requires lowercase characters for
the file specification and path name of all design
files. Therefore, the system automatically
converts any input for the file specification and
path name of a design file (such as a model or
drawing) to lowercase before loading into the
Project Control Database.
Display-List Boxes
A display-list box is located at the end of some
key-in fields. It lets you select data from a list
instead of keying in information. For example,
there is a display list associated with the
Authorization key-in field shown. At the end of
the field, there is a small box with horizontal
dashes. When you select this display list box
with the screen cursor, an associated list of
valid input values displays. Select an item
from the list to enter its value into the field.
Shift Left and Shift Right buttons
At the bottom of some key-in and display fields,
there are two buttons marked with arrows.
These buttons are called shift left and shift right
buttons. Often, you can key in more characters
than a field display shows. Shift Left moves
the text display to the front of the field; Shift
Right moves the text display to the end of the
field.
Toggle
A toggle field on a screen menu enables you to
select one of two possible choices, one of which
is always displayed. Place a data point on the
toggle field to toggle between the two choices.
Roll-Through List
A roll-through list shows one choice at a time of
a list that can be several items long. Place a
data point on the roll-through list to scroll
through the available options. The option
displayed is active.
Standard Window Icons
When using this software, you can press <D>
along the edge of a form or any area not
occupied by a button, key-in field, or other
gadget, to display a box of icons. You can
manipulate form windows just like any other
workstation window.
The following list defines the available window
icons.

26

Plant Design System (PDS) Reference Data Manager (PD_Data)

PDS Environment
Collapse/Restore
Repaint
Pop-to-bottom
Modify/Resize
Pop-to-top
Restore Size

Path Location Fields


Some key-in fields are used to specify paths for various files and folders, such as project folders,
model files, reference data files, drawing files, and isometric drawing files. Prior to PDS 8.0, these
path fields required the user to enter a full path, including the drive name, such as
d:\project1\piping\models. Beginning with PDS 8.0, path fields accept share names as input. For
example, if you have the project1 folder set up as a share, you could enter \project1\piping\models
or project1\piping\models as the path for piping models.
This new functionality allows administrators to set different permissions for shares used by
different sets of users. For more information on setting up shares and permissions, see the PDS
Project Setup Technical Reference.

Plant Design System (PDS) Reference Data Manager (PD_Data)

27

SECTION 3

Batch Processes
When you install the PDS 3D applications, the system creates the necessary batch queues for
that application. Refer to Loading Products in the Project Administrator Reference Guide for a
listing of the batch queues.
PDS 3D uses these batch queues to allow you to continue working in the environment while the
system processes a request. Many of the batch processes can be delayed for submission at a
specified time.

Help
On-line Help is a special feature of your application software. Help provides
instant access to information from the application reference documents, such as
command descriptions and explanations, prompt sequences, and much more.
There are several avenues you can take to find information about a command or subject. For
instance, Help provides
A table of contents that lists subjects by topic and subtopic (in a hierarchy).
An alphabetized index of every command or subject that has been documented for the
software.
A glossary to help you become familiar with product-specific terms.
The ability to move up, down, back, and forth through Help by using cross-references and links
to primary and secondary commands.
The ability to quickly search through Help for information on a specific subject or command.

When you first select Help, the Help Table of Contents is displayed in a pop-up window. Select a
topic from this list or select a command from the menu to display an article in the pop-up window.
Whenever possible, PDS Help is context sensitive. For example, if you select the help icon for a
given form, Help that is specific to that form is displayed.
The Help window has buttons that you can use to manipulate either Help or the window itself as
follows:
Scroll Bar - Moves up or down in an article that is displayed in the Help window.

Plant Design System (PDS) Reference Data Manager (PD_Data)

29

PDS Environment
Help Command Buttons - Enable you to move around in the Help file.
Cancel or File > Exit - Exits Help and closes the Help window.
1. Select the Help button from the command window or form.

If you select Help while using a command, help on the active command is displayed. If no
command is active, the table of contents is displayed.

2. Use the command buttons or scroll bar to move around in Help.


OR
Exit Help.

30

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 4

Reference Data Manager


The Reference Data Manager provides access to the various functions associated with the PDS
3D Reference Database. Select the Reference Data Manager option from the PD Shell form.

Select the option to be performed.


Spec Writer Used to create, modify, and delete information in the Material Reference
Database using a forms interface. See Spec Writer (on page 74).
Piping Job Specification Manager Used to create, modify, and delete information in the
Material Reference Database using neutral files. See Piping Job Specification (on page 41) and
Piping Job Specification Manager (on page 107).
Piping Job Specification Tables Used to create, modify, and delete information in the Piping
Job Spec Table Library. See Piping Job Specification Tables (on page 135) and Piping Job
Specification Tables Command (on page 173).
Piping Job Spec Report Manager Used to define and generate reports of data in the Material
Reference Database. See Piping Job Spec Report Manager (on page 114).
Graphic Commodity Library Manager Used to create, modify, and delete graphic commodity
library data (Eden modules). See Graphic Commodity Library (on page 183) and Graphic
Commodity Library Manager (on page 199).
Physical Data Library Manager Used to create, modify, and delete physical data (dimension
tables) in object and text libraries. See Physical Data Tables (on page 194) and Physical Data
Library Manager (on page 208).

Plant Design System (PDS) Reference Data Manager (PD_Data)

31

Reference Data Manager


Material Description Library Manager Used to create and modify alphanumeric commodity
data. See Material Description Data (on page 269) and Material Description Library Manager (on
page 282).
Support Tutorial Definition Manager Used to create, revise, and delete data in the Tutorial
Definition Library. See Pipe Support Tutorial Definition Manager (on page 323).
Standard Note Library Manager Used to create, revise, and report the code lists and
standard notes associated with the PDS 3D modules. See Standard Note Library (on page 331)
and Standard Note Library Manager (on page 334).
Label Description Library Manager Used to define the graphic parameters for a label (such
as level, line weight, and color code) and to define the format of the label (what information
comprises the label). See Label Description Library (on page 343) and Label Description Library
Manager (on page 347).
Piping Assembly Library Manager Used to create, revise, and delete piping assembly
definitions in the Piping Assembly Library. The Piping Assembly Language (PAL) enables you to
define the parameters necessary to place a piping assembly (group of components) automatically
in the model. See Piping Assembly Library (on page 373) and Piping Assembly Library Manager
(on page 386).
Table Checker Used to verify that all the commodity spec tables, entries, and Eden modules
for a piping materials class exist in the graphic data libraries for the project. See Table Checker
Form (on page 293).
Reference Database Revision Manager Used to create a set of reports for coordinating
revisions in the Reference Database and the implied changes which are required in the model.
See Reference Database Revision Manager (on page 395).
Reference Database Management Data Used to define the file names for Reference
Database Files, graphic commodity data, dimension tables, and spec tables. You can define both
approved or unapproved RDB data for each item. See Reference Database Management Data
(on page 36).
Default Project Control Data Used to define the default location for the source files used to
load the RDB files (such as neutral files, program files, and report files). See Default Project
Control Data (on page 35).
MicroStation V7 Checker Used to find any MicroStation V8 design files in a project. This
utility generates an ASCII - based log file, which provides a report on files contained in the project.
You can then remove any MicroStation V8 files from the project. See MicroStation V7 Checker (on
page 415).

Data Security
The Reference Data Manager provides data security features for the following reference data
libraries in the event of accidents such as, electrical power surges and network failures. These
features also protect the libraries in the event that a library is being shared by multiple projects,
and different users in different projects mistakenly attempt to revise one of the libraries
simultaneously.
Graphic Commodity Library
Physical Data Library
Piping Job Specification Table Library
Short Material Description Library
Long Material Description Library
Specialty Material Description Library
Standard Note Library

32

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Data Manager


Label Description Library
Piping Assembly Library
When you enter the Reference Data Manager to create, revise, or delete data in any of the these
libraries, the system creates a temporary file for that library. This temporary file is named
<library_specification>.c and will be created in the same directory location as the object library.
Once you successfully exit the applicable library manager, the system deletes the temporary file. If
a PDS user is unable to exit the Reference Data Manager for any reason (such as a power
failure), the system displays a dialog box when the next user enters the Reference Data Manager
to revise that library. You must decide which of the following situations applies and respond
accordingly.

If you are certain that the warning results from a previous unusual exit, make one of the
following decisions.
If a corrupted library (including the corresponding source library and revision library) has
been restored from a backup, select the accept option.
If you are concerned with the integrity of the library for any reason, select the exit option.
Then restore the library, the corresponding source library, and the corresponding revision
library to their previous state (before the last revisions).
If you are aware that a different user may be revising that library within a different project,
select the exit option.

This feature requires that PDS users have write access to the directory in which the
libraries reside. The Reference Data Manager will display an error message, if the user does
not have privileges for write access to the applicable directory and the user will not be able to
revise that library.
When a PDS user exits a data creation or revision session, the Reference Data Manager verifies
the integrity of the binary tree structure within the library. The system displays an error if the
Reference Data Manager determines that an error exists in the binary tree structure. In this event,
you should contact Intergraph immediately for assistance in repairing the library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

33

Reference Data Manager

Reference Data Archival


PDS includes a Project Archival Manager to provide archival and retrieval facilities for projects,
including reference data. For more information about the Project Archival Manager, see Project
Archival Manager in the Project Administrator Reference Guide. For specific information about
archiving reference data, see Reference Data in the Project Administrator Reference Guide.

34

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 5

Reference Data Location


This section describes the options used to define the location of the Reference Data files on the
network.
Reference Database Management Data (on page 36) Defines the location for Reference
Database Files, graphic commodity data, dimension tables, and spec tables. You can define
both approved or unapproved RDB data for each item.
Default Project Control Data (on page 35) Defines the default location for the source files
used to load the RDB files (such as neutral files, language files, and report files).

Default Project Control Data


This option defines the default location for common reference files used by the project (such as
neutral files, report files, and library files). You can also change these file locations during the
operation of the applicable managers

Operating Sequence
1. Select Default Project Control Data from the Reference Data Manager form to define the
default location for the RDB source files.
2. Select the field to be defined and key in the location of the source files and the associated
node name.
Piping Eden Path / Node The default location for the Eden source files.
Dimension/Spec Table Path / Node The default location of the Dimension Table and
Spec Table source files.

Plant Design System (PDS) Reference Data Manager (PD_Data)

35

Reference Data Location


Piping Spec Path / Node The default location for the neutral files to be used to load
the Specification/Material Reference Database and Material Description Libraries.
Assembly Path / Node The default location for the Piping Assembly Language source
files.
Standard Note Library Path / Node The default location for the Standard Note (code
list) source files.
Equipment Eden Path / Node The default location for the Equipment Eden source
files.
TDF Table Path / Node The default location for the Equipment table definition files.
Model Builder Path / Node The default location for the model builder language source
files.
3. Accept any changes to the Project Control Data.

Reference Database Management Data


This option activates the Reference Database Management Data form used to define the file
names for Reference Database Files, graphic commodity data, dimension tables, and spec
tables. You can define both approved or unapproved RDB data for each item.

Operating Sequence
1. Select Reference Database Management Data from the Reference Data Manager form.

2. Select RDB File Type


Select the RDB file from the list of files. You can use the scroll arrows to scroll through the
listed files.

The system identifies the file for the selected field in the fields at the bottom of the form.
There are no default settings for these files; you must define the applicable file locations
before you can continue.

36

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Data Location


Material/Specification Reference Database This field identifies the Material
Reference Database for the project. Refer to the Project Setup Manager in the Project
Administrator Reference Guide for more information on this database.
Piping Job Specification Tables (on page 135) Library This field identifies the location
of the Piping Job Spec Table library.
Short Material Description Library (on page 273) This field identifies the library which
contains the short bill-of-material description for all piping commodity items and the BOM
description addenda for taps.
Long Material Description Library (on page 279) This field identifies the library which
contains the long BOM description for all piping commodity items. The long BOM
description is only used for requisitions.
Specialty Material Description Library (on page 281) This field identifies the library
which contains the BOM description for engineered items, in-line instruments, and pipe
supports. This library tends to be customer-specific.
Standard Note Library (on page 331) This field identifies the location of the standard
note library.
Label Description Library (on page 343) This field identifies the location for the label
description library.
Piping Assembly Library (on page 373) This field identifies the location for the Piping
Assembly library. This library contains the symbol definitions for assemblies.
Graphic Commodity Library (on page 183) This field identifies the library which
contains the Eden modules used to place components in the model.
Physical Data Tables (on page 194) Library These fields identify the library files which
contain the physical data tables for a range of geometric industry standards.
Commodity Synonym Library This field identifies the user-defined library which
contains the map for translating the default piping commodity names used in the P&ID
Task to names specified by the user in the Piping Job Specification.
Orthographic Drawing Borders This field identifies the drawing border files to be
used when creating drawings. A set of border files are delivered to the directory
win32app\ingr\pddraw\border. You must specify which style of borders is to be used.
Key in any changes to the selected RDB files. Refer to Delivered Reference Data (on page
18) for a listing of the delivered reference data files.
If you specify an unapproved file, the system will use the unapproved file for all Reference
Data Manager operations (such as revising entries in a library.)
Refer to the Project Data Manager in the Project Administrator Reference Guide for
information on setting the choice of data for a model file or drawing.
You can select Approved --> Not Approved to copy the approved definition of the selected
RDB file to the Not Approved fields. Select confirm to update the information.
Refer to the individual managers for information on posting the unapproved information to the
approved files.
You can select Default All Library Locations to define a default location for all approved and
all unapproved library files.
You can select Copy All Standard Libraries to copy the delivered library files to a specified
location.
Select Accept following each change to the reference data to accept the specified file
location.
THEN
Select Cancel to exit the form.

3.

4.

5.
6.
7.

Plant Design System (PDS) Reference Data Manager (PD_Data)

37

Reference Data Location


Default All Library Locations
This option assigns a default network address, pathname, and file specification to the various
Reference Database libraries for both the approved and unapproved libraries. You can override
any of these default specifications by selecting the appropriate library and keying in the file
information.
Specify Default Nodename
Key in a default network address and pathname to be used for all approved Reference Database
libraries and a network address and pathname to be used for all unapproved libraries.
The file specifications for all libraries are determined automatically on the basis of the industry
practice and the following naming convention.
When copying the Not Approved library to the Approved library, the copy will not occur
if the approved library is the most recent or has the same date as the unapproved library.
Library

File name

Graphic Commodity Library

pipe_gcom.l

Label Description Library

labels.l

Standard Note Library

std_note.l

Piping Assembly Library

assembly.l

Piping Spec Table Library

pjs_tbl.l

Short Material Description Library

short_bom.l

Long Material Description Library

long_bom.l

Specialty Description Library

spclty_bom.l

Physical Data Library

<standard>_pcdim.l

The text to be used for the <standard> is determined in the following manner.

38

Practice

Prefix

U.S. Practice

us

European - DIN

din

European - British Standard

bs

European - Practice A

eua

European - Practice B

eub

International - JIS

jis

International - Australian

aus

International - Practice A

ina

International - Practice B

inb

Company Practice

cmp

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Data Location


Copy All Standard Libraries
This option copies the delivered Reference Database libraries from the applicable product
directories to the disk locations specified in the Reference Database Management data of the
Project Control database.
This option provides a new user with a simple method to create a Reference Database using RDB
products delivered by Intergraph. This is not intended for use in a production environment.
The following Reference Database libraries are copied from the PD Shell product.
Graphic Commodity Library

Standard Note Library

Label Description Library


Piping Assembly Library
The following Reference Database libraries are copied from the applicable Reference Database
product (such as rdusrdb or rddinrdb).
Physical Data Library

Long Material Description Library

Piping Spec Table Library

Specialty Description Library

Short Material Description Library


The system also copies the applicable Table Revision Management Libraries for the Piping Spec
Table Library and Physical Data Libraries.
The text to be used for the standard is determined in the following manner.
Practice

Prefix

U.S. Practice

us

European - DIN

din

European - British Standard

bs

International - JIS

jis

International - Australian
aus
The list of available products is determined from the list of exported variables as specified in the
pds.cmd shell script. Therefore, this command presently searches for the following exported
variables:
Product

Practice

RD_USRDB

U.S. Practice

RD_DINRDB

DIN

RD_BSRDB

British Standards

RD_JISRDB

JIS

RD_AUSRDB
Australian
The file specification recorded in the Project Control Database, and not that of the library in the
delivered product, will be used for the destination library.
If the RDB product resides on a remote server (or workstation), you must manually mount
the directory that includes the RDB product and change the exported variable in the pds.cmd shell
script accordingly.
The system will display an error message for any of the following conditions.
Any of the active Reference Database libraries for the project are in use (locked). None of the
libraries are copied.

Plant Design System (PDS) Reference Data Manager (PD_Data)

39

Reference Data Location

40

The network address for any of the active Reference Database libraries for the project is
undefined. None of the libraries are copied.
The network address and path name for any of the active Reference Database libraries for the
project cannot be mounted. None of the subsequent libraries are copied.

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 6

Piping Job Specification


The Piping Job Specification (PJS) defines the characteristics, properties, design standards, and
company practices associated with piping commodity items, piping engineered items, and
instruments. When you select an item for placement in the model, the system uses the active
parameters (such as piping materials class and nominal diameter) to search the Piping Job
Specification for the selected item. Then the system reads the PJS for the parameters required to
define the item.

See Also
Material Reference Database Structure (on page 41)
Spec Writer (on page 74)
Piping Job Specification Manager (on page 107)
Piping Job Spec Report Manager (on page 114)

Material Reference Database Structure


The Material Reference Database contains a set of tables which define the Piping Job
Specification data. The numbers in parentheses indicate the database table number.
Piping Materials Class Data (201) (on page 45)
Piping Commodity Specification Data (202) (on page 48)
Piping Specialty Specification Data (203) (on page 56)
Instrument Component Specification Data (204) (on page 58)
Tap Properties Data (205) (on page 61)
Piping Commodity Size-Dependent Material Data (211) (on page 64)
Piping Commodity Implied Material Data (212) (on page 66)
Component Insulation Exclusion Data (231) (on page 69)
Flange Insulation Exclusion Data (232) (on page 71)
Piping Construction Tolerance Exclusion Data (233) (on page 73)
The Piping Commodity Specification Data is linked to the Piping Materials Class Data.
The Reference Database Revision Management Data table is totally system-defined. It
stores the revision dates for the other database tables in the Material Reference Database. The
revision dates are updated automatically when you use the Piping Job Spec Manager to load,
revise, or delete data in these database tables.

Attribute Types
The following conventions are used to designate the field type for database attributes.
character(n)

alphanumeric field n characters in length

integer

long (double word) integer

short

short integer

double

real (floating point) value

standard note nnnn Standard Note Type for code-listed attribute

Plant Design System (PDS) Reference Data Manager (PD_Data)

41

Piping Job Specification


Code-Listed Attributes
A code-listed attribute is an attribute whose value must be defined using one of the selections from
a particular code list in the Standard Note Library. In the following database description,
attributes which are code-listed are identified by a standard note number at the end of the line
following the field type description. For example, the line
6. fluid_code
, character(6)
, SN 125
indicates that fluid_code is defined in terms of code list numbers belonging to Standard Note
125, Fluid Code/Connector Type. A possible entry for this attribute would be 197 for chlorine gas
(GCL). Refer to Appendix: Codelists (see "Table Checker" on page 291) for a listing of the code
list sets associated with PDS 3D.

Connect Point Data


The Piping Commodity, Piping Specialty, and Instrument database tables classify connect point
dependent data about a component in terms of green and red connect points. The following
conventions are used to coordinate the two sets of data:
If data is only shown under the green connect point, it applies to all ends of the component.
If a component has ends with different nominal diameters (regardless of other end properties),
the larger nominal diameter is designated as the green connect point.
If a component has ends with the same nominal diameter but other end properties which differ,
the following rules apply:
If the ends have different termination types (regardless of the values for
schedule/thickness), the end(s) whose end preparations have the lowest codelist number
are designated as the green connect point.
If the termination types are the same but the values for rating, schedule, or thickness
differ, the "stronger" ends(s) are designated as the green connect point.

NPD Units
Nominal piping diameter is defined as a special coded number (NPD units) with the following
formula.
For metric units, the coded number equals the size (in millimeters).
For English units, the coded number equals the size (in inches) times 32 plus 5000.
This allows nominal piping diameter to range from 1 mm to 5000 mm in 1 mm increments for
metric units, and to range from 1/32" to at least 200" in 1/32" increments for English units.

Neutral File Input


A neutral file is an ASCII text file used to load information into the Material Reference Database.
The neutral file must conform to the following rules:
There must be an entry for each user-defined parameter in the Material Reference Database.
For certain attributes, you can use a dash (-) to indicate that a default value be used.
The SEQUENCE statement can be used to define the order of entries in the neutral file.

42

The system_unique_no attribute is never user-defined. Therefore, it should not be


included in the neutral file data or in the list of attributes defined by the SEQUENCE
statement.
Each entry (attribute) can begin at any point along the input. You can set the spacing
between each entry by specifying SINGLE_SPACING or DOUBLE_SPACING as the first item in
the file. If you do not define the spacing, double spacing is used.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

For single line comments, place an exclamation point (!) at the beginning of the line. All
comments are disregarded by the system.
You can place blank lines anywhere in the file for readability. These lines do not affect the
information being copied.
You can use any of the three PDS conventions to enter fractional Nominal Piping Diameters.
The entries
2-1/2 2.5 2 1/2
are all equivalent ways of entering the same figure.
If you use the SINGLE_SPACING option, 2 1/2 can be used only if enclosed by single
quotes ('2 1/2').
You can use both metric and English units. The default system of units must be declared once
in the beginning and each time the default system is changed. Entries are automatically
interpreted as English. To declare the system of units, add the appropriate units marker to the
entry:
mm for metric
" for English
The Tap Properties Table must include the Table Name along with other data by using the
TABLE statement.

SEQUENCE Statement
The SEQUENCE statement is an optional statement which can be used to define the order of the
parameters in the neutral file. If the SEQUENCE statement is used, it must be placed before any
entries. The SEQUENCE statement can only be used once per file.
If the SEQUENCE statement is omitted, it is assumed that the parameters appear in the
order defined by PDS.
Format
SEQUENCE= P1 P2 P3 P4 ... Pn
where:
SEQUENCE=

keyword which can be entered in either upper or lower case


letters.

P1,P2,...Pn

parameters 1 through n. The values of P1...Pn are the


parameter numbers assigned by PDS, and their position tells the
system the order in which to enter them.
At least two spaces must separate the keyword and each
parameter.

Examples
SEQUENCE=

The first parameter read corresponds to PDS parameter #5, the second to PDS parameter #3, the
third to PDS parameter #4, the fourth to PDS parameter #1, and the fifth to PDS parameter #2.
You can use the convention *Pn to indicate an attribute that is not defined in the neutral file. All of
the *Pn attributes should be placed at the end of the SEQUENCE statement following the list of
included attributes. For example,
SEQUENCE= 2 3 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 *4 *5 *21 *22

Plant Design System (PDS) Reference Data Manager (PD_Data)

43

Piping Job Specification


ORDER Statement
Neutral files translated from VAX PDS data may contain an ORDER statement rather than a
SEQUENCE statement. This statement performs the same function as the SEQUENCE
statement except that it lists the order of the attributes as they were defined in the VAX Piping Job
Specification Database.

TABLE Statement
The TABLE statement defines a table name to be associated with a particular set of data. The
active table name remains unchanged until another TABLE statement is encountered. The
TABLE statement can be used more than once in a neutral file.
Format
TABLE= table_name
where
TABLE=

keyword which can be entered in upper or lower case letters.

table_name
the name of the table associated with the following data.
There must be at least one/two spaces (depending on the default spacing selected) between the
keyword and the table_name.
For example, the Tap Properties Table below defines two tables (C001, and C002) by using the
Table keyword to segregate the data for each table being defined.
Double_Spacing
Order= 2 3 5 4 6 7
! By=GJH
Ckd By=RJW
Rev=2
Date=12-May-1995
Table= C001
! Description= SWE CL3000 default taps
! Diam
Opt Rating Prp Sc/Th Tap Code
0.375 691 591 NREQD E$37591XXX
> 0.5
1
CL3000 421 NREQD E$50421064
0.5
691 591 NREQD E$50591XXX
:
:
30
691 591 NREQD E030591XXX
32
691 591 NREQD E032591XXX
34
691 591 NREQD E034591XXX
36
691 591 NREQD E036591XXX
42
691 591 NREQD E042591XXX
48
691 591 NREQD E048591XXX
Table= C002
! Description= SWE CL6000 default taps
! Diam
Opt Rating Prp Sc/Th Tap Code
0.375 691 591 NREQD E$37591XXX
> 0.5
1
CL6000 421 NREQD E$50421072
0.5
691 591 NREQD E$50591XXX
:
:
34
691 591 NREQD E034591XXX
36
691 591 NREQD E036591XXX
42
691 591 NREQD E042591XXX
48
691 591 NREQD E048591XXX

44

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Piping Materials Class Data (201)


The piping materials class data is independent of nominal piping diameter and commodity item.
A piping materials class defines a classification of components based on design data and service
limits. Much of the design data is stored in tables so that common information can be accessed by
more than one piping materials class.
The Piping Materials Class Data table contains 23 attributes.
1. system_unique_no, integer
2. piping_mater_class, character(16)
This attribute identifies the service number, spec class, spec name, or spec number.
3. revision_no, character(2)
This attribute identifies the revision number for the data in the piping materials class. It is
user-defined and is not updated automatically when the piping commodity data for that piping
materials class is revised.
The revision number of the unapproved Material Reference Database is incremented
only, when you specify a new revision number in the neutral file.
The revision number of the approved Material Reference Database is updated to that of
the unapproved Material Reference Database, when the unapproved data is posted to the
approved Material Reference Database.
4. version_no, character(2)
This attribute represents the version number, as determined by the system, for the data in this
piping materials class (including the Commodity Item data). The version number starts with
A and is incremented (B,C,D,...) when you revise the piping materials class. This attribute is
under the complete control of the system.
The Piping Job Spec Manager increments this attribute when the piping commodity data for
that piping materials class is revised or reloaded. When that piping materials class is posted
from the unapproved to the approved Material Reference Database, the version number for
that piping materials class is reset to A in the unapproved Material Reference Database.
5. revision_date, character(10)
This user-defined attribute can be used to define a date for the latest revision to the data in a
piping materials class.
6. fluid_code, character(6), SN 125
This attribute can be used to define the type of fluid for which the piping materials class is
intended.
You can specify:
a single fluid code value (such as 521 for process) from code list set 125.
the name of a fluid code table to define a set of fluid code values. Refer to Fluid Code
Table (on page 151) for more information.
To use the specified fluid code(s), you must also set the Fluid Code Control toggle to Yes on
the Piping Data Control form of the Project Data Manager. Refer to the Project
Administrator (PD_Project) Reference Guide for more information on this form.
7. mater_of_construct, character(6)
This attribute defines the materials of construction class for the piping materials class. This
code has a detailed definition outside the scope of PDS that represents the decision of the
Project Metallurgist regarding the piping system. It is required for reporting and making

Plant Design System (PDS) Reference Data Manager (PD_Data)

45

Piping Job Specification


matches and comparisons with values for this parameter from the Piping Design Database.
This parameter includes the material code.
8. corrosion_allow, double
This attribute defines the corrosion/erosion allowance that applies to the piping materials
class. It is required for reporting and to calculate the wall thickness of piping components
whose thickness is not specifically included in the piping materials class.
9. mat_description, short, SN 148
This code-listed attribute is a generic description of the materials used for this piping materials
class (such as carbon steel). This attribute is only used for reporting.
10. service_lim_table, character(6)
This attribute identifies the table used to determine maximum pressure as a function of
temperature. This table includes the pressure and temperature sets that form the boundary
for which the commodity items, engineered items, and instruments included in this piping
materials class are suitable (unless you define a lower maximum temperature limit for a
specific commodity item). You must insure that all commodity items within the piping
materials class are acceptable within the boundary of this table.
Refer to Temperature and Pressure Service Limits Table (on page 136) for more information
on this table.
11. diameter_table, character(6)
This attribute identifies the nominal piping diameter table used to verify valid nominal piping
diameters in this piping materials class. Refer to Nominal Piping Diameters Table (see
"Nominal Piping Diameter Table" on page 137) for more information.
12. thickness_table, character(6)
This attribute identifies the thickness data table used in piping wall thickness calculations for
this piping materials class. Refer to Thickness Data Tables (on page 140) for more
information.
13. materials_table, character(6)
This parameter defines the materials data table used to determine the material properties
required for piping wall thickness calculations in the piping materials class. Refer to
Materials Data Table (on page 142) for more information.
14. thickness_equation, character(6)
This attribute identifies the default piping wall thickness equation to be used for this piping
materials class. If a schedule/thickness parameter for an item specifies the default
calculation, then this equation is used to perform the piping wall thickness calculation. Refer
to Wall Thickness and Branch Reinforcement Equations (on page 152) for more information.
15. branch_table, character(6)
This attribute identifies the branch insertion table used to determine the name of the branch
commodity item to be used for tee and lateral branches. The item name is determined as a
function of branch geometry, run size, and branch size. The output of the branch table is the
item name of a commodity item (AABBCC code).
Refer to Branch Insertion Tables (on page 145) for more information.
16. tap_data_table, character(6)
This attribute defines the name of the tap properties table which includes those parameters
required to define a tap on a specific commodity item. Refer to Tap Properties Data (205) (on
page 61) for more information.
17. vent_drain_macro, character(6)

46

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


This attribute is not currently used by the PDS software. Several vent and drain definitions are
contained in the delivered Piping Assembly Library.
18. gasket_separation, character(8)
This attribute is used to determine the actual gap that is assumed between seating surfaces of
two mating bolted ends. It can coincide with, but is not necessarily the compressed gasket
thickness. You can override this value during a design session by changing the type of
gasket that applies to the joint. (You cannot override this value by defining a specific gasket
gap override value.)
This attribute exists as alphanumeric data.
A value with all numeric characters is interpreted as a gasket separation value in the
physical subunits specified for the model.
All other values are assumed to identify a table name for gasket separation data as a
function of nominal piping diameter in the Piping Graphic Commodity Library. Refer to
Gasket Separation Table (on page 149) for more information.
Refer to the description of gaskets in the PDS Piping Component Data Reference Guide for
more details.
19. standard_note_no_a, short
, SN 499
20. standard_note_no_b, short

, SN 499

These code-listed attributes provide the index numbers to CL499 for notes that apply to this
piping materials class. The input to the Standard Note Library is the note number. The
output is the free- format text which forms the standard note.
In the delivered data, note numbers 1 through 199 are allocated for defining the PJS.
21. revision_mngt_date, integer
This system-defined attribute identifies the date of the latest revision for the data in this piping
materials class.
22. bend_deflect_table, character(6)
This attribute identifies the Bend Deflection Table to be used for this piping materials class.
This attribute is useful for defining specs for underground piping.
If this column is undefined (blank), the system will use the default Bend Deflection Table
specified in the Type 63 data through the Project Data Manager. Therefore, you need not
define a Bend Deflection Table for each piping materials class in the Material Reference
Database. Likewise, you need not revise any existing neutral files to include this column.
Note that the Bend Deflection Table name in the Piping Materials Class data is limited to 6
characters to be consistent with the other tables referenced in this data. The maximum
length of the default Bend Deflection Table name, as specified with the Project Data
Manager can be as many as 20 characters.
Refer to Bend Deflection Table (G04) (on page 158) for more information.
23. pipe_length_table, character(6)
This attribute identifies the Pipe Length Threshold Table to be used for this piping materials
class. This attribute is useful in defining specs for underground piping.
If this column is undefined (blank), the system will use the default Pipe Length Threshold
Table specified in the Type 63 data through the Project Data Manager. Therefore, you need
not define a Pipe Length Threshold Table for each piping materials class in the Material
Reference Database.
Note that the Pipe Length Threshold Table name in the piping materials class data is limited to
6 characters to be consistent with the other tables referenced in this data. The maximum

Plant Design System (PDS) Reference Data Manager (PD_Data)

47

Piping Job Specification


length of the default Pipe Length Threshold Table name, as specified with the Project Data
Manager can be as many as 13 characters.
Refer to Pipe Length Threshold Table (G07) (on page 160) for more information.

Neutral File Format


The following is a sample neutral file for the Piping Material Class database table. Entries in this
table should be sorted alphanumerically by Piping Materials Class.
The Sequence= keyword in a piping materials class data neutral file does not require *21 for the
revision management date. Any previously created piping materials class data neutral files will
not require any revision as a result of this change.

Sample Files
A sample neutral file for US practice is delivered in the file
\win32app\ingr\rdusrdb\spec_data\classes.pmc. A set of sample files depicting various options
are delivered in the \win32app\ingr\pddata\sample\data directory.
bend_tbl.pmc

gasket.pmc

pharm.pmc

equiv_npd.pmc

gskt_tbl.pmc

piplen_tbl.pmc

fluid_code.pmc

metric_npd.pmc

thickness.pmc

fpipe.pmc

Piping Commodity Specification Data (202)


The Piping Commodity Specification Data defines all the components, pipes, bolts, and gaskets
associated with a particular Piping Materials Class. It defines the standard components found in
a manufacturers catalog (commonly referred to as off-the-shelf components). Because the Piping

48

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Commodity Specification Data is linked to the Piping Materials Class, a separate set of commodity
items must be defined for each Piping Materials Class.
Information for connect point data is defined in terms of two types of connect points known as
green and red connect points. Refer to Connect Point Data (on page 196) for more information on
green and red connect points.
The Piping Commodity Specification Data table contains 28 attributes:
1. system_unique_no, integer
2. piping_mater_class, character(16), index 1
This attribute identifies the Piping Materials Class for the piping commodity.
3. commodity_name, character(6)
This attribute identifies the commodity item name. This can be:
a PDS commodity item name. Refer to the PDS Piping Component Data Reference
Guide for more information on item names.
a Piping Job Specification access name. If you do not use the AABBCC code, you must
define a Commodity Synonym Library for proper communication with the P&ID Task.
The PDS commodity item names are also used with the delivered Place Component
forms. If you use a different code, you should create a forms customization file as
defined in the Piping Designer.
4. option_code, short, SN 400
This code-listed attribute identifies the option code which determines the search criteria.
This parameter enables you to request that the system retrieve the primary commodity item, a
secondary commodity item, or another special option from the Piping Job Specification.
This parameter is used as a commodity override in Piping Design. You can select the unique
options (as defined in CL400) from a form. If no option is specified at placement, this
attribute defaults to option 1 (primary commodity item). Option 2 is reserved as the
secondary commodity item.
Option codes 4001 to 4010 are used to specify manual input of bend data for pipe bends.
Option codes 4500 to 4999 are reserved for company practice (user-defined).
Option codes 5000 to 5999 are used to refer to implied components.
5. maximum_temp, double
This attribute is used if the commodity item is temperature dependent. It represents the
maximum temperature for which this commodity item is acceptable. When a commodity item
is retrieved from the Piping Job Specification, the system verifies that the normal operating
temperature, the alternate operating temperature, the normal design temperature, and the
alternate design temperature are less than this maximum allowable temperature. If this
maximum is exceeded by any of these temperatures, the system automatically searches for
another occurrence of the same commodity item.
For gaskets, to help determine the gap thickness at bolted joints, the maximum
temperature value is used as an input to the Gasket Gap Table. Proper entry of
temperature values in the PJS assists the definition of gap thicknesses when gaskets with
different gap thicknesses are used in the same piping materials class.
If you specify the default value (-9999), no test is performed. Any reports created from the
Piping Job Specification depict this default value as alphanumeric blanks.
The order in which entries of the same piping commodities with different maximum
temperature values are made in the PJS (PDtable_202) is not considered by the system;
however, these entries must have the same option code in order to be considered by the
commodity selection in the Place Component command. When you do define the piping
commodity, a maximum temperature value must be defined for each entry or an error

Plant Design System (PDS) Reference Data Manager (PD_Data)

49

Piping Job Specification


message is displayed. To define the highest maximum temperature for the same piping
commodity, set the maximum temperature equal to or greater than the maximum temperature
of the spec limits table for the applicable piping materials class instead of using an undefined
value ('-').
6. gcp_from_nom_diam, short (NPD Units)
7. gcp_to_nom_diam, short (NPD Units)
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the green connect point (first size) in NPD units. The to value must equal or
exceed the from value. These values are not necessarily the same as the range in Tables
211 and 212. The applicable NPD value specified at placement is used to search for the
suitable component in the Piping Job Specification.
The default system of units (" for inches, or mm for millimeters) must be declared once in the
beginning and each time the default system is changed. If no units are given, the value is
automatically interpreted as inches.
8. gcp_end_prep, short, SN 330
This code-listed attribute identifies the end preparation for the green connect point. The
system determines the termination type based on the range of values:
2 - 199 bolted terminations
300 - 399 male terminations
400 - 599 female terminations
You can define end compatibilities by using the End Preparation Compatibility Table. (Refer
to the Project Data Manager in the Project Administrator Reference Guide.)
9. gcp_rating, character(8)
This attribute identifies the pressure rating for the green connect point. This parameter exists
as alphanumeric data. The system interprets the first set of sequential numeric characters as
being the pressure rating value.
Ratings can be expressed in any of the following formats: CLxxxx, xxxx#, or OTxxxx.
However, table entries and file names representing the rating exclude the CL, #, or OT
characters. This enables the same table to be used regardless of how the rating is defined.
In the delivered PJS, these rating formats are used in accordance with the following criteria:
CLxxxx refers to an ANSI or API pressure rating
xxxx# refers to a pressure rating defined by an organization other than ANSI or API.
OTxxxx refers to the rating of a connect point that meets the applicable ANSI or API rating
geometrically but not from a pressure carrying standpoint. An example is a valve
supplied with flanged ends that meets the bolting pattern of ANSI CL150 pressure rating
but has pressure carrying characteristics different from those of that ANSI rating.
For bolts and gaskets, you must use a numeric pressure rating (do not use the
characters CL, #, or OT). If any character entries are encountered, the system will be unable
to locate the proper information.
Female ends for plastic pipe are usually defined in terms of schedule/thickness and not in
terms of rating. To make female ends for plastic pipe follow the rules for other female ends,
the applicable schedule/thickness is used as the value for rating. If such rating values
consist of alphanumeric characters, the system strips all alpha characters from the rating
value and uses only the numeric values in accessing the applicable tables.
If the rating in the PJS is expressed in terms of alphabetic characters only, the system uses
the characters in accessing the data tables. The names of the data tables include all the
alphabetic characters included in the PJS.

50

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

GRAVHD can be used to identify the rating for components rated to sustain a nominal
fluid head. This value can be used in the PJS and in the data tables.
OTHER can be used to identify a non standard rating value.
NONE can be used to identify the rating for components whose ends would normally
require the attribute rating as part of the table name, but for which a rating does not apply.
This value can be used in the PJS and in the data tables.
10. gcp_sch_thk, character(8)
This attribute identifies the schedule thickness value for the green connect point. This
parameter exist as alphanumeric data. (Refer to Wall Thickness and Branch Reinforcement
Equations (on page 152) for more information on this attribute.) In order of preference,
schedule, and thickness are expressed in terms of:
A generic schedule such as S-STD, S-XS, and S-XXS. If a schedule name exceeds the
provided field length (for example, S-SDR13.5), it is defined in terms of its wall thickness.
A specific schedule such as S-40, S-40S, and S-80.
NREQD is used in cases where all of the following conditions apply:
The thickness value is not required in purchasing the component.
Empty weights are not significantly affected by actual thickness values.
Either stress analysis is not applicable, or, if applicable, the component is to be
considered infinitely rigid in stress analysis calculations.
A value with all numeric characters is interpreted as a wall thickness value in the same
physical units as nominal piping diameter. To insure compatibility between the PJS, data
tables, and wall thickness calculations, thickness is expressed in the form:
.xxxx if the thickness is less than 1 inch
x
if the thickness is an even inch
x.xxx if the thickness is 1 inch or larger
Trailing zeroes are not included. Decimal points are not included for numbers without
decimals.
An asterisk (*) followed by a name (of the form Cyyy) defines the specific calculation or
table lookup to be used for wall thickness. Refer to Wall Thickness and Branch
Reinforcement Equations (on page 152) for a more detailed description of the naming
conventions for these calculations.
MATCH indicates the need to match the thickness of a component to that of the pipe of
the same diameter and of option 1.
11. gcp_table_suffix, short, SN 576
This code-listed attribute is used to further reference the source of the generic dimensional
data, such as flange data or piping outside diameter data. This attribute is also referred to as
the table suffix.
For AMS standards, it represents the table suffix for the green connect point.
For DIN standards, it represents the piping outside diameter selection flag (reihe number)
for pipes and fittings.
12. rcp_from_nom_diam, short
13. rcp_to_nom_diam, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the red connect point (second size). The to value must equal or exceed the from
value. These values are not necessarily the same as the range in Tables 211 and 212.

Plant Design System (PDS) Reference Data Manager (PD_Data)

51

Piping Job Specification


For a full size component, you should set these parameters to
- (hyphen). In cases such
as a concentric reducer or weldolet, this value must be less than the corresponding green
value.
14. rcp_end_prep, short, SN 330
See gcp_end_prep.
15. rcp_rating, character(8)
See gcp_rating.
16. rcp_sch_thk, character(8)
See gcp_sch_thk.
17. rcp_table_suffix, short, SN 577
This attribute is used to further reference the dimensional data for a specific component.
For AMS standards, it represents the table suffix for the red connect point.
For DIN standards, it represents the built-in length selection flag (or reihe number) for
valves and wall thickness selection flag for pipes and fittings.
A parametric definition is used when connection graphics are required in the model and
orthographic drawings.
18. commodity_code, character(16)
The commodity code is a user-assigned code that together with the NPD and
schedule/thickness uniquely defines the component. It defines the customer's commodity
code (or part number). This attribute is the index into the Material Data Tables and the
Material Description Library. The commodity code can be defined in one of three ways:
Commodity codes with neither an * or a + prefix, indicate a commodity item that has no
associated implied components.
Commodity codes prefixed by an *, indicate a commodity item (primary component) which
has one associated implied component (such as a lap joint flange and stub end). For
more information on defining * implied items, refer to the PD_Report User's Guide.
It is not recommended that specification implied (*) items be generated by size
change components (that is, reducers, reducing flanges, and so forth) as the NPD
assigned by the system for the implied component can be either the larger or smaller
(green or red) NPD of the implying item based on how the system traces the line.
Commodity codes prefixed by a +, indicate a commodity item (primary component) which
has one or more associated implied components as defined in Table 212.
The default length for a commodity code is 16 characters, but you can modify this length if
needed. This value is specified in two files: design.ddl and reference.ddl. To customize
the character length, modify the design.ddl file as follows:
In table 34 (Piping Component Data), modify the value in column 8.
In table 50 (Piping/Tubing Data), modify the value in column 12.
Modify the reference.ddl file as follows:
In table 202 (Piping Commodity Specification Data), modify the value in column 18.
In table 211 (Piping Commodity Size-Dependent Material Data), modify the values in
column 2 and column 7.
In table 212 (Piping Commodity Implies Material Data), modify the values in column 2 and
column 7.
When you modify these values, set the character limit to be one more than the
number of characters you actually want in the commodity code. This is necessary for

52

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


you to add a * or + prefix if needed. For example, to create a 20-character commodity
code, set the specified values to 21.
You must make these modifications before the project is created.
For valves, the commodity code also defines the name of the dry weight table (required for
stress analysis). For large diameter valves (25"+), it is used to build the name of the operator
dimension table.
19. model_code, character(6)
This attribute identifies the specific item name for generic bends, spec flanges, or spec valves.
Each model code is classified by:
Item name
option
size ranges
end preparations
ratings
The model code includes the definition of the graphic representation of the component in the
piping model. Depending upon the circumstances:
One or more model codes can be assigned to a single Item Name (for example, GAT,
GATR, and GATF are all used for 6Q1C01).
The same model code can be assigned to different Item Names.
For gaskets, this attribute can be used to prioritize gasket entries in the Piping Materials
Class. The priority is set with a numeric value (integer or decimal) greater than zero.
Non-numeric values are ignored by MTO and not considered to be a priority selection. The
smaller the value the higher the priority. A value of 999999 is interpreted as an undefined
priority.
20. PDS_sort_code, character(6)
This field can be used to specify the length (in subunits) for Purchased length pipe, or to
specify the gasket diameter for gaskets. The gasket diameter table is used if the
pds_sort_code for the gasket spec entry is set to _GKT. The system uses the NPD to
determine the gasket inside and outside diameters.
If the pds_sort_code for the gasket spec entry is set to "_GKT", the gasket outside and
inside diameters are generated using the table gasket_commodity_code_GKT.TBL.
If the pds_sort_code for the gasket spec entry is not "_GKT", the gasket outside diameter
is equivalent to the NPD of the rated component and the gasket inside diameter is
undefined.
21. modifier, double
This attribute is used for pipe bends, elbows, miters, and valves. It has various uses
depending on the type of commodity item as defined below.
For pipe bends, it defines the bend radius of the pipe in terms of the numeric factor by
which the nominal diameter of the pipe is to be multiplied to obtain the bend radius.
You can provide additional bend data for pipe bends in the Commodity Options section
of the Place Component command. If you specify a commodity option code with a value
between 4001 and 4010 in the Reference Database, you can specify the bend radius and
lengths of the straight pipes in the dialog box that displays. You can also specify the bend
radius as a length in sub-units or a function of the nominal piping diameter.
The Piping Eden module that supports this option uses the length of the straight section
located at connect point 1 as Dimension_1 and the length of the straight section located

Plant Design System (PDS) Reference Data Manager (PD_Data)

53

Piping Job Specification


at connect point 2 as Dimension_2. You can also specify that these two lengths are the
same.
The default data displayed in the dialog box contains the following values:
The pipe bend radius is computed from the default modifier value in the Piping
Commodity Data for the selected pipe bend, active nominal piping diameter, model
system of units, and NPD system of units.
The length of the straight section at end 1 is zero by default.
The length of the straight section at end 2 is zero by default.
When this option is used for placement of a pipe bend, the lengths of the straight section
are loaded into the Piping Design Database as dimension_a for end 1 and dimension_b
for end 2. This data is saved for reconstruction.
For pipe, it defines the joint quality factor (E) times 100 to be used during branch
reinforcement calculations in those cases where the wall thickness is not calculated.
For orifice flanges and drip ring tees, it defines the number of taps to be provided. A
value of 1 defines a single tap. A value of 2 defines 2 taps, 180 degrees apart. A value
of negative 2 (-2) defines 2 taps, 90 degrees apart.
For nippolets and nipples, it defines the length of the component.
For reinforcing pads and welds, it defines whether data about the component is to be
derived from tables in the system (0) or from the user by prompting (1).
For gaskets, it defines the gasket thickness to be used in procuring the gasket. This is
the actual gasket thickness for MTO reports - not the compressed gasket thickness
(gasket separation), which is derived from the Piping Materials Class data.
For bolts, it defines whether the bolt is a stud bolt (0 or positive), or machine bolt
(negative). The absolute value of this modifier, which ranges from 0 to 5, determines the
applicable bolt extension.
For valves, it represents the code list number from CL550 (operator/actuator type) which
defines the symbol description and the source of the physical data for the valve operator.
If this value is a negative number (such as -3), the operator is not displayed when placing
the component.
22. geometric_standard, short, SN 575
This code-listed attribute identifies the source of the data (which is usually an industry
standard, such as ANSI, ISO, or DIN, or a company standard) from which the specific
geometry of the commodity item can be deduced. This parameter represents the vendor or
industry standard, and the material if either affects the dimensions of the commodity item.
Code list numbers 2-6999 are reserved for geometry standards that apply to US piping
practices. Numbers 7000-27999 are reserved for geometry standards that apply to
European piping practices. Numbers 28000-31999 are reserved for specific company
practices.
23. weight_code, short, SN 578
This code-listed attribute defines the weight code for the component. It determines the table
to be used in finding the dry weight of the component. It is required for those cases where
material causes the dry weight data but not the dimensional data to differ for a specific
geometric industry standard.
24. fabrication_cat, short, SN 180
This code-listed attribute identifies the shop/field fabrication and purchase status of a
component. It defines how the component was supplied and how the component was
fabricated (for example, Shop Supplied, Field Fabricated).
25. materials_grade, short, SN 145

54

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


This code-listed attribute identifies the material code, specification, grade-temper, and joint
efficiency for the component. This data is used in wall thickness calculations. It can also be
used to access physical data in the Physical Data Library.
26. standard_note_no_a, short, SN 499
27. standard_note_no_b, short, SN 499
These code-listed attributes provide index numbers to standard notes in standard note type
499 that apply to this commodity item. The input to the Standard Note File is the note
number. The output is the free-format text which forms the standard note.
In the delivered data, note numbers 200 through 599 are allocated for piping commodity
items.
28. input_form_type, short, SN 990
This code-listed attribute defines the type of input form to be used to define data with the Spec
Writer command.

Neutral File Format


The following is a partial listing of the sample neutral file for the Piping Commodity Specification
Data. Entries in this table should be sorted alphanumerically by commodity_name.
The Sequence= keyword in a piping commodity data neutral file does not require the *2 for the
piping materials class name. Any previously created piping commodity data neutral files will not
require any revision as a result of this change.

Sample Files
A set of neutral file for US practice are delivered in the files
\win32app\ingr\rdusrdb\spec_data\*.pcd (one for each piping materials class specified in the
classes.pmc file).
A set of sample files depicting various options are delivered in the
\win32app\ingr\pddata\sample\data directory.
bend_tbl.pcd

gasket.pcd

pharmf.pcd

equiv_npd.pcd

gskt_tbl.pcd

pharmk.pcd

fluid_code.pcd

metric_npd.pcd

piplen_tbl.pcd

fpipe.pcd

pharm.pcd

thickness.pcd

Plant Design System (PDS) Reference Data Manager (PD_Data)

55

Piping Job Specification

Piping Specialty Specification Data (203)


This database table contains data for a specific specialty item. It is used to define those specialty
items which are used frequently by a particular company or installation. The specialty items are
defined for the entire project, they are not partitioned by Piping Materials Class.
The Piping Specialty Specification Data table contains 26 attributes.
You can also place specialty items interactively in the model by defining the necessary
parameters at the time of placement. No entries in the PJS database are required for these
interactive definitions. Refer to the Piping Design Graphics Reference Guide for more
information on placing specialty items.
1. system_unique_no, integer
2. piping_comp_no, character(20)
This attribute uniquely identifies the specialty component number. It is sometimes referred to
as Item Number.
3. model_code, character(6)
This attribute identifies the piping specialty name. This can be a Piping Job Specification
access name or a PDS commodity item name.
4. option_code, short, SN 400
This code-listed attribute identifies the option code which determines the search criteria.
This parameter enables you to request that the system retrieve the primary item, a secondary
item, or another special option from the Piping Job Specification. You can select the unique
options (as defined in standard note 400) from a form. If no option is specified at placement,
the primary item is used. Option 2 is reserved as the secondary item. This parameter is
used as a component override in the Piping Designer.
5. gcp_from_nom_diam, short (NPD Units)
6. gcp_to_nom_diam, short

(NPD Units)

These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the green connect point.
7. gcp_end_prep, short, SN 330
These attributes identify the end preparation for the green/red connect point. This value is an
intelligent code list. The system determines the termination type based on the range of
values:
2 - 199 bolted terminations
300 - 399 male terminations
400 - 599 female terminations
8. gcp_rating, character(8)
These attributes identify the pressure rating for the green/red connect point. This parameter
exists as alphanumeric data. The system interprets the first set of sequential numeric
characters as being the pressure rating value. (Refer to the description of pressure rating
under Piping Commodity Data for more information on standard formats.)
9. gcp_sch_thk, character(8)
These attributes identify the schedule or thickness value for the green/red connect point.
This parameter exist as alphanumeric data. (Refer to the description of schedule and
thickness for more information on standard formats.)
10. gcp_table_suffix, short, SN 576

56

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


These code-listed attributes identify the source of the generic dimensional data, such as
flange data or piping outside diameter data.
For AMS standards, it represents the table suffix for the connect point.
For DIN standards, it represents the piping outside diameter selection flag (reihe number)
for pipes and fittings.
11. rcp_from_nom_diam, short (NPD Units)
12. rcp_to_nom_diam

, short

(NPD Units)

These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the red connect point. For a full size component, these values are set to zero.
13. rcp_end_prep, short, SN 330
See gcp_end_prep.
14. rcp_rating, character(8)
See gcp_rating.
15. rcp_sch_thk, character(8)
See gcp_sch_thk.
16. rcp_table_suffix , short, SN 577
See gcp_table_suffix.
17. physical_data_id , character(8)
This parameter can be used to identify the name of the physical dimension table in the
Physical Data Library to be used for this engineered item.
18. PDS_sort_code, character(6)
This attribute can be used to define an arbitrary index to a geometric data table for piping
specialties. This is an optional input.
19. modifier, double
This attribute is used for pipe bends, elbows, and miters. It represents the bend radius in
terms of the nominal piping diameter.
20. geometric_standard , short, SN 575
This attribute provides a reference to the source of the data (which is usually an industry
standard, such as ANSI, ISO, or DIN, or a company standard) from which the specific
geometry of the commodity item can be deduced.
21. weight_code, short, SN 578
This code-listed attribute defines the weight code for the component. It determines the table
to be used in finding the dry weight of the component. It is required for those cases where
material causes the dry weight data but not the dimensional data to differ for a specific
geometric industry standard.
22. fabrication_cat, short, SN 180
This code-listed attribute identifies the shop/field fabrication and purchase status of a
component. It defines how the component was supplied and how the component was
fabricated (for example, Shop Supplied, Field Fabricated).
23. materials_grade, short, SN 145
This code-listed attribute identifies the material code, specification, grade-temper, and joint
efficiency for the component. It can be used to access physical data in the Graphic
Commodity Library.
24. standard_note_no_a, short, SN 499

Plant Design System (PDS) Reference Data Manager (PD_Data)

57

Piping Job Specification


25. standard_note_no_b, short, SN 499
These attributes provide index numbers to standard notes in 499 that apply to this specialty
item. The input to the Standard Note File is the note number. The output is the free-format
text which forms the standard note.
In the delivered data, note numbers 600 through 799 are allocated for piping specialties.
26. input_form_type, short, SN 990
This code-listed attribute defines the type of input form to be used to define data with the Spec
Writer command.

Neutral File Format

Sample Files
A sample neutral file is delivered in the file \win32app\ingr\pddata\sample\data\specialty.data.
A sample file containing various bio-pharmaceutical specialty items is delivered in the file
\win32app\ingr\pddata\sample\data\pharms.data.

Instrument Component Specification Data (204)


This table contains the data for a specific instrument item. It is used to define the instruments
which are used frequently by a particular company or installation. The instruments are defined
for the entire project; they are not partitioned by PMC. The following data exists in the Instrument
table.
The Instrument Component Specification Data table contains 26 attributes.
You can also place instruments interactively in the model by defining the necessary
parameters at the time of placement. No entries in the PJS database are required for these
interactive definitions. Refer to the Piping Design Graphics Reference Guide for more
information on placing instruments.
1. system_unique_no, integer
2. instrument_comp_no, character(20)
This attribute identifies the tag number for the instrument item. You can modify the character
length for this attribute.
3. model_code, character(6)
This attribute identifies the specific item name for generic bends, spec flanges, or spec valves.
This can be a Piping Job Specification access name or a PDS commodity item name. Refer
to the PDS Piping Component Data Reference Guide for more information on item names.

58

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


4. option_code, short, SN 400
This code-listed attribute identifies the option code which determines the search criteria.
This parameter enables you to request that the system retrieve the primary item, a secondary
item, or another special option from the Piping Job Specification. You can select the unique
options (defined in a standard note) from a form. If no option is specified at placement, the
default option 1 is used. Option 2 is reserved as the secondary item. This parameter is
used as a component override in Piping Design.
5. gcp_from_nom_diam, short (NPD Units)
6. gcp_to_nom_diam

, short (NPD Units)

These coded attributes identify the range of nominal piping diameters (low bound to high
bound) for the green connect point.
7. gcp_end_prep, short, SN 330
These code-listed attributes identify the end preparation for the green/red connect point. The
system determines the termination type based on the range of values:
2 - 199 bolted terminations
300 - 399 male terminations
400 - 599 female terminations
8. gcp_rating, character(8)
These attributes identify the pressure rating for the green/red connect point. This parameter
exists as alphanumeric data. The system interprets the first set of sequential numeric
characters as being the pressure rating value. (Refer to the description of pressure rating for
more information on standard formats.)
9. gcp_sch_thk, character(8)
These attributes identify the schedule thickness value for the green/red connect point.
(Refer to the description of schedule and thickness for more information on standard formats.)
10. gcp_table_suffix, short, SN 576
These code-listed attributes reference the source of the generic dimensional data, such as
flange data or piping outside diameter data.
For AMS standards, it represents the table suffix for the connect point.
For DIN standards, it represents the piping outside diameter selection flag (reihe number)
for pipes and fittings.
11. rcp_from_nom_diam, short (NPD Units)
12. rcp_to_nom_diam, short (NPD Units)
These coded attributes identify the range of nominal piping diameters (low bound to high
bound) for the red connect point. For a full size component, these parameters are set to zero.
13. rcp_end_prep, short, SN 330
See gcp_end_prep.
14. rcp_rating, character(8)
See gcp_rating.
15. rcp_sch_thk, character(8)
See gcp_sch_thk.
16. rcp_table_suffix, short, SN 577
See gcp_table_suffix.
17. physical_data_id , character(8)

Plant Design System (PDS) Reference Data Manager (PD_Data)

59

Piping Job Specification


This parameter can be used to reference the set of physical data from the Physical Data
Library to be used for this instrument item.
18. PDS_sort_code, character(6)
This attribute can be used to define an arbitrary index in the geometric data table for
instruments. This is an optional input.
19. modifier, double
This parameter, if applicable, is used to determine the type of valve operator for instrument
valves. It specifies the identification of the symbol description and the source of the physical
data for a valve operator.
20. geometric_standard, short, SN 575
This code-listed attribute identifies the source of the data (which is usually an industry
standard such as ANSI, ISO, or DIN; or a company standard) from which the specific
geometry of the commodity item can be deduced.
21. weight_code, short, SN 578
This code-listed attribute defines the weight code for the instrument. It determines the table
to be used in finding the dry weight of the instrument. It is required for those cases where
material causes the dry weight data but not the dimensional data to differ for a specific
geometric industry standard.
22. fabrication_cat, short, SN 180
This code-listed attribute identifies the shop/field fabrication and purchase status of a
component. It defines how the component was supplied and how the component was
fabricated (for example, Shop Supplied, Field Fabricated).
23. materials_grade, short, SN 145
This code-listed attribute identifies the material code, specification, grade-temper, and joint
efficiency for the instrument. It can be used to access physical data in the Piping Graphic
Commodity Library.
24. standard_note_no_a, short, SN 499
25. standard_note_no_b, short, SN 499
These code-listed attributes provide the index number to standard notes in NL499 that apply
to this instrument. The input to the Standard Note File is the note number. The output is the
free-format text which forms the standard note.
In the delivered data, note numbers 800 through 999 are allocated for instruments.
26. input_form_type, short, SN 990
This code-listed attribute defines the type of input form to be used to define data with the Spec
Writer command.

60

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Neutral File Format

Sample Files
A sample neutral file is delivered in the file \win32app\ingr\pddata\sample\data\instrment.data.
A sample file containing various bio-pharmaceutical instruments is delivered in the file
\win32app\ingr\pddata\sample\data\pharmi.data.

Tap Properties Data (205)


This table contains the tap properties data that is a function of the tap properties table name and
the nominal piping diameter. These tables define the piping taps which can be added to any of
the components included in a piping materials class. The system uses the information in these
tables and the nominal diameter to provide values for rating, end preparation, schedule/thickness,
and tap code. Tap tables do not allow a NPD range; there must be an individual entry for each
tap diameter.
The NPD entry in the tap table should be either imperial units or metric units depending on the
NPD requirements of the project. For imperial units, enter the specified NPD, such as 0.375. The
software will provide a default unit of inches when the value is loaded into the project. For metric
NPD units, enter the units after the value on the first NPD entry.
For example:
! Diam
Opt
Rating
Prp
SC/Th
Tap Code
10mm
1
591
NREQD
E$37591XXX
20
691
591
NREQD
E$37581XXX
The Tap Properties Data table contains 8 attributes.
The following kinds of taps may be defined in this table:
No-hole taps that permit the subsequent placement of a pipe support trunnion. For example,
a no-hole tap may be placed on an elbow or tee to allow the subsequent placement of a pipe

Plant Design System (PDS) Reference Data Manager (PD_Data)

61

Piping Job Specification


trunnion for a pipe support; the diameter of this no-hole tap must be defined to have the same
nominal diameter as the component part on which placed.
Hole taps that permit the subsequent placement of piping, piping components, and instrument
components. For example, a hole tap may be placed on a cap to allow the subsequent
placement of a reducing component such as a flatolet; the diameter of this hole tap must be
defined to have the same nominal diameter as the component part on which placed. A hole
tap can also be placed on a blind flange to allow the placement of plain piping; the diameter of
this hole tap must be defined to have the same nominal diameter as the plain piping.
Hole taps that permit the venting or draining of a piping and/or instrument component. For
example, a hole tap can be placed on an elbow downstream of a relief valve; the diameter of
this hole tap must be defined to have the same nominal diameter as the desired drain hole.
Component taps that represent a tap connection, rather than a hole. For example, a
socketwelded component tap may be placed on a gate valve to represent a socketwelded
connection furnished by the valve manufacturer. The diameter of this component tap must
be defined to have the same nominal diameter as the desired connection.
1. system_unique_no, integer
2. tap_table_name, character(6)
This attribute identifies the name of the Tap Properties Data Table. These tables use the
following naming conventions:
first character: C
next three characters: numbers from 001 through 999 used to make the table name
unique.
The combination of the tap properties table name, the tap NPD, and the tap option, must be
unique.
3. nominal_piping_dia , short
This attribute defines the value for the nominal tap diameter.
4. option_code, short, SN 400
This code-listed attribute identifies the option code which determines the search criteria.
This parameter enables you to request that the system retrieve the primary item, a secondary
item, or another special option from the Piping Job Specification. If no option is specified at
placement, this attribute defaults to option 1 (primary item). This parameter is used as a
component override in Piping Design.
5. end_preparation, short, SN 330
This code-listed attribute identifies the end preparation. The system recognizes a certain
range of values as being flanged termination types, another range as being butt welded
termination types, and so forth.
6. rating, character(8)
This attribute exists as alphanumeric data. The system interprets the first set of sequential
numeric characters as being the pressure rating value. (Refer to the description of pressure
rating for Piping Commodity Data for more information on standard formats.)
7. sched_thick, character(8)
This attribute identifies the generic or specific schedule, a thickness value, or a calculation.
(Refer to the description of schedule and thickness for Piping Commodity Data for more
information on standard formats.)
8. tap_material_code, character(10)
This optional attribute can be used to access the Material Description Library for the tap's
material description addendum. It must be a unique reference to the Material Description

62

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Library, including material descriptions for commodity items. In reporting or isometric
extraction, this text can be appended to either the short or long descriptions of the component
to which the tap applies.
This attribute is also referred to as the Tap Code. Refer to the listing of the tap descriptions in
the Short Material Description Library (on page 273) for more information on the tap
commodity code.

Neutral File Format


6 8
Double_Spacing
Sequence= 3 4 6 5 7
! By=GJH
Ckd By=RJW

8
Rev=2

Date=12-May-1988

Table= C001
! Description= SWE CL3000 default taps
! Diam
Opt Rating Prp Sc/Th Tap Code
0.375 691 591 NREQD E$37591XXX
> 0.5
1
CL3000 421 NREQD E$50421064
0.5
691 591 NREQD E$50591XXX
> 0.75
1
CL3000 421 NREQD E$75421064
0.75
691 591 NREQD E$75591XXX
> 1
1
CL3000 421 NREQD E001421064
1
691 591 NREQD E001591XXX
> 1.25
1
CL3000 421 NREQD E1$2421064
1.25
691 591 NREQD E1$2591XXX
> 1.5
1
CL3000 421 NREQD E1$5421064
1.5
691 591 NREQD E1$5591XXX
> 2
1
CL3000 421 NREQD E002421064
2
691 591 NREQD E002591XXX
2.5
691 591 NREQD E2$5591XXX
> 3
1
CL3000 421 NREQD E003421064
3
691 591 NREQD E003591XXX
3.5
691 591 NREQD E3$5591XXX
> 4
1
CL3000 421 NREQD E004421064
4
691 591 NREQD E004591XXX
5
691 591 NREQD E005591XXX
6
691 591 NREQD E006591XXX
8
691 591 NREQD E008591XXX
10
691 591 NREQD E010591XXX
12
691 591 NREQD E012591XXX
14
691 591 NREQD E014591XXX
16
691 591 NREQD E016591XXX
18
691 591 NREQD E018591XXX
20
691 591 NREQD E020591XXX
24
691 591 NREQD E024591XXX
26
691 591 NREQD E026591XXX
28
691 591 NREQD E028591XXX
30
691 591 NREQD E030591XXX
32
691 591 NREQD E032591XXX
34
691 591 NREQD E034591XXX
36
691 591 NREQD E036591XXX
42
691 591 NREQD E042591XXX
48
691 591 NREQD E048591XXX

Plant Design System (PDS) Reference Data Manager (PD_Data)

63

Piping Job Specification

Sample Files
A sample neutral file for US practice is delivered in the file
\win32app\ingr\rdusrdb\spec_data\taps.data.
A sample file containing various bio-pharmaceutical tap properties is delivered in the file
\win32app\ingr\pddata\sample\data\pharm_tap.data.

Piping Commodity Size-Dependent Material Data (211)


The Size-Dependent Data table contains the data for a specific commodity item that is dependent
on the commodity code, nominal piping diameter, and schedule/thickness.
This table is used for miscellaneous batch reporting, such as construction cost reports and
requisition orders, and interfaces to material control, stress analysis, and isometric drawing
extraction.
There are multiple occurrences for a specific commodity code and a specific pair of green and red
nominal piping diameters in the Piping Commodity Size-Dependent Material Data table because
schedule/thickness is not included in the commodity code.
When reducing branch components are to be entered, items of equal size must be placed
before items of unequal size.
The Piping Commodity Size-Dependent Material Data table contains 10 attributes.
1. system_unique_no, integer
2. sys_commodity_code, character(16)
This parameter identifies the customer's commodity code (or part number). You can modify
the character length for this attribute.
3. gcp_nom_diam, short
4. rcp_nom_diam, short
These coded attributes identify the nominal piping diameter for the green/red connect point in
NPD Units.
5. gcp_sch_thk, character(8)
6. rcp_sch_thk, character(8)
These attributes identify the schedule thickness value for the green/red connect point. This
parameter exist as alphanumeric data.
A generic schedule such as S-STD, S-XS, and S-XXS. If the schedule name exceeds the
provided field length, it is defined in terms of its wall thickness.
A specific schedule such as S-40, S-60, and S-80.
NREQD is used if the thickness value is not required in purchasing the component, empty
weights are not significantly affected by actual thickness values, and stress analysis is not
applicable.
A value with all numeric characters is interpreted as a wall thickness value in the same
physical units as nominal piping diameter.
An asterisk (*) followed by a name (of the form Cyyy) defines the specific calculation or
table lookup to be used for wall thickness.
7. commodity_code, character(16), index 1

64

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


This attribute identifies the customer's commodity code or vendor's part number. It is not
required for the customer's commodity code if the customer's commodity code is not
dependent upon nominal piping diameter or thickness.
8. weld_weight, double
This parameter represents the total weld required at all welded ends of the commodity item.
9. unit_price, double
This attribute identifies the unit price (materials cost) for the commodity item.
10. manhours, double
This attribute identifies the unit manhours associated with the commodity item.

Neutral File Format

A sample neutral file is delivered in the file \win32app\ingr\pddata\sample\data\pcd_size.data.

Data Retrieval
The data retrieval from the Size-Dependent Data table involves data for a commodity item that is
dependent upon nominal piping diameter and schedule/thickness. This form of data retrieval is
used during the MTO report creation process.

inputs (search criteria)


pointer to the commodity item dependent data
NPD green - first size
NPD red - second size
schedule/thickness - green connect point
schedule/thickness - red connect point

outputs
customer's commodity code or vendor's part number
weld data
price data (materials cost) - unit price
labor data - unit manhours

Plant Design System (PDS) Reference Data Manager (PD_Data)

65

Piping Job Specification

Piping Commodity Implied Material Data (212)


The Implied Material Data table contains the implied material data for a specific commodity item
that is dependent on both the Piping Commodity Library code and nominal piping diameter range.
This data is used strictly for generating implied material for MTO reporting and material control. It
is reserved for spec implied material, such as caps or stubs, for a specific commodity item. It is
also used for reporting the implied components of a commodity item (for example, cap screws).
The Piping Commodity Implies Material Data table contains 10 attributes.
The entries in this tables should not be confused with mating implied items (such as welds,
bolts, nuts, or gaskets) which are generated automatically by the system. Refer to the Report
Manager (PD_Report) User's Guide for more information on implied items.
A unique commodity code must be defined for each commodity definition. For example, if a
commodity code is defined for gate valves from 2" to 14", but you want a different description for
an 11" gate valve, you must assign a new commodity code to the 11" valve.
1. system_unique_no, integer
2. sys_commodity_code, character(16)
This parameter identifies the customer's commodity code (or part number), if it is not
dependent upon nominal piping diameter. You can modify the character length for this
attribute.
3. gcp_from_nom_diam, short
4. gcp_to_nom_diam, short
These coded attributes identify the range of nominal piping diameters for the green connect
point in NPD units. These values are not necessarily the same as the range in the Piping Job
Specification.
NPD is defined as a special coded number with the following formula.
for Metric units, the coded number equals the size (in millimeters)
for English Units, the coded number equals the size (in inches) times 32 plus 5000.
coded number = 32*diameter + 5000 (in)
This allows nominal piping diameter to range from 1 mm to 5000 mm in 1 mm increments for
metric units, and to range from 1/32" to at least 200" in 1/32" increments for the English
System of Units.
5. rcp_from_nom_diam, short
6. rcp_to_nom_diam

, short

These coded attributes identify the range of nominal piping diameters for the red connect
point in NPD units. These values are not necessarily the same as the range in the Piping Job
Specification. For a full size component, these parameters should be set to '-'.
7. commodity_code
, character(16) , index 1
This attribute identifies the Piping Commodity code of the implied material. It is used to
generate an MTO line item as a result of a piping commodity item in the Piping Design model.
The implied material is generated by accessing the Piping Commodity Library - not by
accessing the Piping Design database.
8. quantity, double
This attribute identifies the quantity of the implied material.
9. fabrication_cat, short

66

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


This code-listed attribute identifies the shop/field fabrication and purchase status of a
component. It defines how the component was supplied and how the component was
fabricated (for example, Shop Supplied, Field Fabricated).
10. standard_note_no , short
This code-listed attribute provides index numbers to standard notes in CL499 that apply to this
implied material.

Plant Design System (PDS) Reference Data Manager (PD_Data)

67

Piping Job Specification


Neutral File Format

68

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Sample Files
A sample neutral file for US practice is delivered in the file
\win32app\ingr\rdusrdb\spec_data\implied.data.
A sample file containing various bio-pharmaceutical gasket data is delivered in the file
\win32app\ingr\pddata\sample\data\pharm_212.data.

Data Retrieval
Data retrieval from the Implied Material Data table involves implied material data for a commodity
item that is dependent on nominal piping diameter range. This form of data retrieval is used
during the MTO Report Creation process and Material Control.

inputs (search criteria)


pointer to the commodity item dependent data

outputs
Commodity code of the implied material
Quantity of the implied material
Fabrication category of the implied material
Standard note for the implied material

Component Insulation Exclusion Data (231)


The Component Insulation Exclusion Data is used to completely or partially exclude the insulation
of components on insulated lines with respect to interference checking.
For each piping component, piping specialty, or instrument component (excluding pipes) on an
insulated line, the Piping Envelope Builder will search the Component Insulation Exclusion Data
Table on the basis of the following data to determine whether or not insulation should be
completely excluded from that component's interference envelope.
green nominal piping diameter of the component (range search)
red nominal piping diameter of the component (range search)
heat tracing requirements (range search)
insulation purpose (range search)
normal operating temperature (range search)
For piping commodities, the Piping Envelope Builder searches for the component's commodity
name in the Component Insulation Exclusion Data Table using the preceding data.
If the piping commodity is defined in the exclusion table for those conditions, the applicable
insulation thickness will not be added to the component's interference envelope.
If the commodity name is not specified in the exclusion table for those conditions, the Piping
Envelope Builder searches for the component's model code using the same data. If a match
for those conditions is found on the basis of model code, the applicable insulation thickness
will not be added to the component's interference envelope.
Otherwise, the insulation thickness will be included in the component's interference envelope.
For piping specialties and instrument components, the Piping Envelope Builder searches for the
component's model code in the Component Insulation Exclusion Data Table using the preceding
data. If the component is defined in the exclusion table for those conditions, the applicable
insulation thickness will not be added to the component's interference envelope. Otherwise, the
insulation thickness will be included in the component's interference envelope.

Plant Design System (PDS) Reference Data Manager (PD_Data)

69

Piping Job Specification


The piping segment data (heat tracing requirements, insulation purpose, and normal operating
temperature) are determined on the basis of the piping segment that is associated with the first
connect point of the applicable component.
The Component Insulation Exclusion Data table contains 13 attributes.
1. system_unique_no, integer
2. commodity_name, character(6)
This attribute identifies the commodity item name of a piping component as defined in the
Piping Commodity Specification Data (Table 202 attribute 3).
If this attribute is blank, the system will search for a match by model code.
3. model_code, character(6)
For piping commodities, this attribute identifies the model code as defined in the Piping
Commodity Specification Data (Table 202 attribute 19).
For piping specialties, this attribute identifies the model code as defined in the Piping
Specialty Specification Data (Table 203 attribute 3).
For instruments, this attribute identifies the model code as defined in the Instrument
Component Specification Data (Table 204 attribute 3).
4. gcp_npd_from, short
5. gcp_npd_to, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the green connect point of the component or instrument in NPD units.
6. rcp_npd_from, short
7. rcp_npd_to, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the red connect point of the component or instrument in NPD units.
For full size components, use a dash (-) for these attributes.
8. heat_tracing_from, short, SN 200
9. heat_tracing_to, short, SN 200
These code-listed attributes identify the range of heat tracing values (lower bound to higher
bound) using values from code list set 200, Heat Tracing Requirements.
A dash (-) can be used for the from value to indicate that heat tracing requirements are not to
be considered as part of the discrimination process.
10. insul_purpose_from, short, SN 220
11. insul_purpose_to, short, SN 220
These code-listed attributes identify the range of insulation purpose values (lower bound to
higher bound) using values from Standard Note type 220, Insulation Purpose.
A dash (-) can be used for the from value to indicate that insulation purpose is not to be
considered as part of the discrimination process.
12. nor_oper_temp_from , double
13. nor_oper_temp_to , double
These attributes identify the range of temperature values (lower bound to higher bound) for
the component or instrument.
A dash (-) can be used for the from value to indicate that temperature is not to be considered
as part of the discrimination process.
The system of units for the temperature range is the same as the system of units for the
maximum temperature in the Piping Commodity Specification Data Table. Note that normal

70

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


design temperature, alternate operating temperature, and alternate design temperature are
not considered.

Neutral File Format


!

DEFINE COMPONENT INSULATION


Single_Spacing
Sequence= 2 3 4 5 6 7 8 9 10 11 12 13
I15AS
4
12
3 3
6Q2C76
4
12
3 3
REDE
4
12
2
10 3 3

EXCLUSION DATA
5
5
5

5
5
5

150
150
150

200
200
200

A sample neutral file is delivered in the file \win32app\ingr\pddata\sample\data\component.data.

Flange Insulation Exclusion Data (232)


The Flange Insulation Exclusion Data provides for partial exclusion of flange insulation thickness
from the generation of interference envelopes. This is an optional data table; if no data is defined
for this table, the Piping Envelope builder will continue to function as it has in previous releases of
PDS.
The Piping Envelope Builder searches for matching data in this table for each bolted end of each
piping component or instrument component on an insulated line that are determined to be
insulated. The system only searches for components that passed the component insulation
exclusion test, as described in Component Insulation Exclusion Data (231) (on page 69).
The Piping Envelope Builder searches for matching data on the basis of the following data to
determine whether or not insulation should be excluded from the flange outside diameter of that
bolted end of the component.
nominal piping diameter of the bolted end (range search)
heat tracing requirements (range search)
insulation purpose (range search)
normal operating temperature (range search)
If matching criteria is found in the exclusion table for these conditions, the applicable insulation
thickness will not be added to the flange outside diameter of the bolted end of that component's
interference envelope. Otherwise, the insulation thickness will be included in the component's
interference envelope.
The piping segment data (heat tracing requirements, insulation purpose, and normal operating
temperature) are determined on the basis of the piping segment associated with the first connect
point of the applicable component.
The Piping Eden modules for the interference envelopes that are to consider the
partial exclusion of insulation from the flange outside diameter of a bolted end must be revised
to accommodate this option. If you do not change any or all of the Piping Eden modules for
the interference envelopes, this table will have no impact and the interference envelopes will
include complete insulation, when applicable.
For example, the required modification to the interference parametric for the weldneck flange
(FWN) is as follows:
!FLANGE - Interference Module
Interference_Parametric_Shape_Definition 'F1A'
Call Define_Connect_Point_Geometry ( LINEAR )

Plant Design System (PDS) Reference Data Manager (PD_Data)

71

Piping Job Specification

!Original
!
!Modified

Call
Call
RETURN
END

Thickness_1 =
Thickness_2 =
Line
Facing_OD_1 =
Line
Facing_OD_1 =
Facing_OD_2 =
Draw_Cylinder
Draw_Cylinder

Thickness_1 + CP_Offset_1
Thickness_2 + CP_Offset_2
Facing_OD_1 + Insulation * 2
Facing_OD_1 + Insulation_1
Facing_OD_2 + Insulation *
( Thickness_1, Facing_OD_1
( Thickness_2, Facing_OD_2

* 2
2
)
)

The Flange Insulation Exclusion Data table has 9 attributes.


1. system_unique_no, integer
2. bolted_npd_from, short
3. bolted_npd_to, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the bolted end of the component or instrument in NPD units.
4. heat_tracing_from, short, SN 200
5. heat_tracing_to, short, SN 200
These code-listed attributes identify the range of heat tracing values (lower bound to higher
bound) using values from code list set 200, Heat Tracing Requirements.
A dash (-) can be used for the from value to indicate that heat tracing requirements are not to
be considered as part of the discrimination process.
6. insul_purpose_from, short, SN 220
7. insul_purpose_to, short, SN 220
These code-listed attributes identify the range of insulation purpose values (lower bound to
higher bound) using values from Standard Note type 220, Insulation Purpose.
A dash (-) can be used for the from value to indicate that insulation purpose is not to be
considered as part of the discrimination process.
8. nor_oper_temp_from, double
9. nor_oper_temp_to, double
These attributes identify the range of temperature values (lower bound to higher bound) for
the bolted end of the component or instrument.
A dash (-) can be used for the from value to indicate that temperature is not to be considered
as part of the discrimination process.
The system of units for the temperature range is the same as the system of units for the
maximum temperature in the Piping Commodity Specification Data Table. Note that normal
design temperature, alternate operating temperature, and alternate design temperature are
not considered.

Neutral File Format


!

72

DEFINE FLANGE INSULATION EXCLUSION DATA


Single_Spacing
Sequence= 2 3 4 5 6 7 8 9

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


4
4
4

12
12
12

3
3
3

3
3
3

5
5
5

5
5
5

150
150
150

200
200
200

Piping Construction Tolerance Exclusion Data (233)


The Piping Construction Tolerance Exclusion Data can be used to completely or partially exclude
construction tolerance from the generation of interference envelopes. This feature only applies
to Piping vs. Piping construction tolerances.

This is an optional data table; if no data is defined for this table, the Piping Envelope builder will
continue to function as it has in previous releases of PDS.
For each piping or instrument component, excluding pipes, the Piping Envelope Builder searches
Table 233 on the basis of the following data to determine whether the Piping versus Piping
construction tolerance should be excluded from that component's interference envelope.
green NPD of the component (range search)
red NPD of the component (range search)
For piping commodities, the Piping Envelope Builder searches for the component's commodity
name in the Piping Construction Tolerance Exclusion Data Table using the preceding data.
If the piping commodity is defined in the exclusion table for those conditions, the applicable
construction tolerance will not be added to the component's interference envelope.
If the commodity name is not specified in the exclusion table for those conditions, the Piping
Envelope Builder will search for the component's model code using the same data. If a
match for those conditions is found on the basis of the model code, the applicable construction
tolerance will not be added to the component's interference envelope.
Otherwise, the construction tolerance will be included in the component's interference
envelope.
For piping specialties and instrument components, the Piping Envelope Builder searches for the
component's model code in the Piping Construction Tolerance Exclusion Data Table using the
preceding data. If the component is defined in the exclusion table for those conditions, the
applicable construction tolerance will not be added to the component's interference envelope.
Otherwise, the construction tolerance will be included in the component's interference envelope.
The Piping Construction Tolerance Exclusion Data table has 7 attributes.
1. system_unique_no, integer
2. commodity_name, character(6)
This attribute identifies the commodity item name of a piping component as defined in the
Piping Commodity Specification Data (Table 202 attribute 3).
If this attribute is blank, the system will search for a match by model code.
3. model_code, character(6)
For piping commodities, this attribute identifies the model code as defined in the Piping
Commodity Specification Data (Table 202 attribute 19).

Plant Design System (PDS) Reference Data Manager (PD_Data)

73

Piping Job Specification


For piping specialties, this attribute identifies the model code as defined in the Piping
Specialty Specification Data (Table 203 attribute 3).
For instruments, this attribute identifies the model code as defined in the Instrument
Component Specification Data (Table 204 attribute 3).
4. gcp_npd_from, short
5. gcp_npd_to, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the green connect point of the component or instrument in NPD units.
6. rcp_npd_from, short
7. rcp_npd_to, short
These coded attributes identify the range of nominal piping diameters (lower bound to higher
bound) for the red connect point of the component or instrument in NPD units.
For full size components, use a dash (-) for these attributes.

Neutral File Format


!

PIPING CONSTRUCTION TOLERANCE EXCLUSION DATA


Single_Spacing
Sequence= 2 3 4 5 6 7
I15AS
4
12
6Q2C76
4
12
REDE
4
12
2
10

A sample neutral file is delivered in the file \win32app\ingr\pddata\sample\data\constol.data.

Spec Writer
This command provides a forms interface for interactively creating, revising, and managing the
following specification data. This interface provides more simplicity and flexibility to a beginner or
a casual user than defining specs with their respective neutral files:
Piping Materials Class Data (201) (on page 45)
Piping Commodity Specification Data (202) (on page 48)
Piping Specialty Specification Data (203) (on page 56)
Instrument Component Specification Data (204) (on page 58)
Tap Properties Data (205) (on page 61)

74

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Piping Commodity Implied Material Data (212) (on page 66)

See Also
Features (on page 75)
RDB Options File (on page 76)

Features
The Spec Writer provides the following general features:
User-specified options for customizing the input of data (RDB_options).
A direct interface to the unapproved Specification Material Reference Database.
On-line validation for the existence of a material description, once the commodity code (or
component number) has been defined.
Optional on-line Table Checker validation using pre-defined Table Checker reports.
Automated selections from the Standard Note Library for code-listed data. The approved
Standard Note Library must have been defined to include the correct data for use in the
Material Reference Database.
Selectable list of acceptable model codes for a specified commodity name.
Context-sensitive user interface. The form options will vary depending on the item being
defined. For example, the creation (and revision) of specification data for bolts and gaskets
will display only those inputs relevant for bolts or gaskets.
Context-sensitive on-line help that is linked to the Piping Component Data Reference Guide
and the Reference Data Manager Reference Guide.

Plant Design System (PDS) Reference Data Manager (PD_Data)

75

Piping Job Specification

RDB Options File


The RDB Options File allows you to customize the data input operations for the Interactive Spec
Writer. You should define an RDB options list, named RDB_options in the project directory. A
default RDB options list is included in the PD_Data sample/data/ directory.
! RDB_options
!
! general items = three main toggles
!
SHORT_COMMODITY_MATERIAL_DESCRIPTION = OFF
LONG_COMMODITY_MATERIAL_DESCRIPTION = OFF
SPECIALTY_MATERIAL_DESCRIPTION = OFF
!
! PDtable_201 items
!
SERVICE_LIMITS_TABLE = LIST, L
NOMINAL_PIPING_DIAMETER_TABLE = LIST, D
BRANCH_TABLE = LIST, B
TAP_PROPERTIES_TABLE = DATABASE
GASKET_SEPARATION_TABLE = KEYIN
THICKNESS_DATA_TABLE = LIST, T
MATERIALS_DATA_TABLE = LIST, M
FLUID_CODE = VALUE
MATERIALS_DESCRIPTION = LIST
!BEND_DEFLECTION_TABLE = LIST, BENDEF
!PIPE_LENGTH_TABLE = LIST, PIPLEN
STANDARD_NOTE = LIST
PROMPT_FOR_TAP_ORIENTATION
!
! PDtable_202 items
!
MODEL_CODE = LIST
VALVE_OPERATOR = LIST
!
!
COMMODITY_NAME<===>MODEL_CODES
!
! Pipe/Tube
PIPING = PIPE, TUBE
!
!
Valves (6Q1C)
!
6Q1C01 = GATSP, GAT, GATF, GATR
6Q1C02 = GATEX, GATEXB, GATEXBB
6Q1C03 = GATCON
6Q1C04 = GATBL
!
! Generic 3-way
6Q1C05 = BAL3P, GLO3W, PLU3W, SLI3W, 3WRV1
!
6Q1C06 = BALF, BALR, BALSP, BALLP, BALVP
6Q1C08 = BAL3P
6Q1C11 = GLOSP, GLO, GLOF, GLOR

76

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


6Q1C12 = GLOASP, GLOA
6Q1C13 = GLO3W
6Q1C14 = GLOY, GLOYF, GLOYR
6Q1C16 = PLUSP, PLU, PLUVP, PLUFB, PLUF, PLUR
6Q1C18 = PLU3W
6Q1C19 = PLU4W
6Q1C22 = NEE
6Q1C26 = BFYLP, BFYHP
6Q1C30 = DIA, DIASP, DIAPL, DIAGL
6Q1C32 = KNF
6Q1C33 = SLI
6Q1C34 = SLI3W
6Q1C37 = CKALSP, CKAL, CKST, BDA, HOSA
6Q1C38 = CKLSP, CKSSP, CKL, CKLF, CKLR, CKS, CKSF, CKSR, CKSY, CKLRY
6Q1C39 = CKWF, CKWFSP
6Q1C40 = CKALSP, CKAL
6Q1C41 = CKST
6Q1C42 = CKAST
6Q1C43 = CKYST
6Q1C50 = CKBP
6Q1C51 = CKAR
6Q1C53 = BDA
6Q1C54 = BDY
6Q1C56 = PIN
6Q1C57 = FLO
6Q1C58 = FOOT
6Q1C62 = TKDR
6Q1C69 = DEL
6Q1C72 = HOS
6Q1C73 = HOSA
!
! Generic Vent/Drain Valve
6Q1C76 = GATSP, GAT, GATF, GATR, BALF, BALR, BALSP, BALLP, BALVP
!
! Generic Instrument Root Valve
6Q1C80 = GATSP, GAT, GATF, GATR, BALF, BALR, BALSP, BALLP, BALVP
!
6Q1C81 = 3WRV1
6Q1C82 = 4WRV1
!
!
On-line Fittings (6P2C) and In-line Fittings (6Q2C)
!
6Q2C01 = FWN, FLWN, FSO, FL, FPL, FSSSO, FSSL, FSSPL, FLSSO, FLSL, FFIL,
FS, FSW, FTHD, FCP
6Q2C03 = FRWN, FRSO, FRPL, FRS, FRSW, FRTHD
6Q2C04 = FEWN
6Q2C06 = FOWNA, FOWNAW, FOWNB, FOWNBW, FOSOA, FOSOAW, FOSOB, FOSOBW, FOSWA,
FOSWAW, FOSWB, FOSWBW, FOTHDA
6Q2C08 = FBLD
6Q2C10 = BLSPO
6Q2C11 = BLSPC
6Q2C12 = BDISC
6Q2C13 = BLPAD
6Q2C14 = T1SPA, T2SPA1

Plant Design System (PDS) Reference Data Manager (PD_Data)

77

Piping Job Specification


6Q2C15 = BLSPA, OPSPA
!
! Generic End
6Q2C16 = FBLD, HDHEMI, HDELIP, HD21, PLUG, CAPBV, CAPOT
!
6Q2C17 = HDHEMI, HDELIP, HD21
6Q2C19 = PLUG
6Q2C21 = CAPBV, CAPOT
!
! Generic Conentric Diameter Change
6Q2C23 = REDC, SWGC, CPLR, INSR1, INSR2
!
! Generic Eccentric Diameter Change
6Q2C24 = REDE, SWGE
!
6Q2C25 = CPL
6Q2C26 = CPLH
6Q2C27 = REDC
6Q2C28 = REDE
6Q2C32 = CPLR
6Q2C35 = SWGC
6Q2C36 = SWGE
6Q2C39 = UN
6Q2C40 = UNO
6Q2C41 = UND
6Q2C43 = HC
6Q2C44 = BUSH
6Q2C46 = INSR1, INSR2
6Q2C47 = PIPB, PIPB2
6Q2C49 = E5
6Q2C51 = E11
6Q2C53 = E22
!
! Generic <45 Degree Direction Change
6Q2C55 = E5, E11, E22, E45TLR, PIPB, PIPB2
!
! Generic 45 Degree Direction Change
6Q2C56 = E45LR, E45, PIPB, PIPB2, E45LT, E453D, E45T3D, E45U, E45ST, E45S,
E45L, M451, M452
!
6Q2C57 = E45
6Q2C59 = E45LR, E45TLR
6Q2C60 = E45LT
6Q2C61 = E453D, E45T3D
6Q2C63 = E45U
6Q2C65 = E45ST
6Q2C66 = E45S
6Q2C68 = E45L
6Q2C73 = E60
!
! Generic 45-90 Degree Direction Change
6Q2C75 = E90TLR, PIPB, PIPB2
!
! Generic 90 Degree Direction Change

78

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


6Q2C76 = E90LR, E90, E90SR, E90LT, E90R, E903D, E903T3D, E90U, E90ST,
E90RST, E90S, E90L, PIPB, PIPB2, E90LT, M901, M902, M903, M904
!
6Q2C77 = E90
6Q2C79 = E90SR
6Q2C80 = E90LR, E90TLR
6Q2C82 = E90LT
6Q2C84 = E90R
6Q2C86 = E903D, E903T3D
6Q2C88 = E90U
6Q2C90 = E90ST
6Q2C91 = E90RST
6Q2C93 = E90S
6Q2C94 = E90L
!
!
On-line Fittings (6P3C) and In-line Fittings (6Q3C)
!
6Q3C01 = R180
6Q3C03 = R180SR
6Q3C05 = R180LR
6Q3C07 = R180CL
6Q3C08 = R180MD
6Q3C09 = R180OP
6Q3C14 = M1, M2, M3, M4
6Q3C16 = M451, M452
6Q3C18 = M901, M902, M903, M904
6Q3C22 = T, TBT
6Q3C24 = TRB, TRBT
6Q3C25 = TRRB
6Q3C27 = TUOR
6Q3C28 = TUOB
6Q3C31 = TST
6Q3C34 = TRI
6Q3C36 = TDRA, TDRAW, TDRB, TDRBW
6Q3C38 = TBA
6Q3C45 = Y
6Q3C47 = L
6Q3C49 = LRB
6Q3C50 = LRRB
6Q3C52 = S90YB
6Q3C53 = S90YRB
6Q3C54 = L90YB
6Q3C55 = L90YRB
6Q3C60 = X
6Q3C62 = XRB
6Q3C63 = XRRB
6Q3C64 = XBA
6Q3C70 = SAD
6Q3C72 = SWOL
6Q3C73 = WOL
6Q3C74 = SOL
6Q3C75 = TOL
6Q3C76 = NOL
6Q3C77 = EOLLR, EOLSR

Plant Design System (PDS) Reference Data Manager (PD_Data)

79

Piping Job Specification


6Q3C78 = LOL
6Q3C79 = FOLHC
6Q3C80 = RPAD, RPAD2
6Q3C82 = RWELD, RWELD2
6Q3C84 = BWELD, BWELD2, BWELD3
6Q3C88 = NIP
6Q3C89 = NIPIL
!6Q3C95 = GASKET
!6Q3C97 = STUD
!6Q3C98 = NUT
!
!
!
VALVE_OPERATOR_LIST
!
!
Handwheels
!
OP_0 = None Required
OP_3 = Handwheel
OP_4 = Handwheel if GCP>RCP
OP_5 = Handwheel, inclined
OP_9 = Wrench, short
OP_11 = Wrench, long
OP_17 = Lever
OP_19 = T-handle, short
OP_21 = T-handle, long
OP_25 = Handwheel, special
OP_27 = Wrench, special
OP_29 = Gear, top mounted handwheel
OP_31 = Gear, top mounted inclined handwheel
OP_33 = Gear, side mounted handwheel
OP_35 = Gear, side mounted inclined handwheel
OP_39 = Lever, quick-action
OP_40 = Post indicator
!
!
Actuators
!
OP_411 = Diaphragm, type 1
OP_412 = Diaphragm, type 2
OP_413 = Diaphragm, type 3
OP_431 = Press-balanced diaphragm type 1
OP_432 = Press-balanced diaphragm type 2
OP_433 = Press-balanced diaphragm type 3
OP_451 = Regulator type 1
OP_452 = Regulator type 2
OP_453 = Regulator type 3
OP_491 = Single acting cylinder type 1
OP_492 = Single acting cylinder type 2
OP_493 = Single acting cylinder type 3
OP_511 = Doulble acting cylinder type 1
OP_512 = Doulble acting cylinder type 2
OP_513 = Doulble acting cylinder type 3
OP_531 = Pilot operated cylinder type 1
OP_532 = Pilot operated cylinder type 2

80

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


OP_533 = Pilot operated cylinder type 3
OP_534 = Pilot operated cylinder type 4
OP_571 = Motor type 1
OP_572 = Motor type 2
OP_573 = Motor type 3
OP_574 = Motor type 4
OP_611 = Digital type 1
OP_651 = Electro-hydraulic type 1
OP_652 = Electro-hydraulic type 2
OP_811 = Weight type 1
OP_851 = Manual type 1
OP_852 = Manual type 2
OP_853 = Manual type 3
OP_854 = Manual type 4
OP_891 = Spring type 1
END_VALVE_OPERATOR_LIST
You can use the following keywords to customize the settings in the RDB options file.

General Items
For piping commodities, you can verify that a material description has been defined in the Short
Material Description Library and/or the Long Material Description Library. For piping specialties
and instruments, you can verify that a material description has been defined in the Specialty
Material Description Library.
SHORT_COMMODITY_MATERIAL_DESCRIPTION = ON or OFF If set to ON, the short
material description is displayed when you specify the commodity code.
If this keyword is not specified in the RDB options file, the default setting is OFF.

LONG_COMMODITY_MATERIAL_DESCRIPTION = ON or OFF If set to ON, the long material


description is displayed when you specify the commodity code.
If this keyword is not specified in the RDB options file, the default setting is OFF.

SPECIALTY_MATERIAL_DESCRIPTION = ON or OFF If set to ON, the specialty material


description is displayed when you specify the commodity code.
If this keyword is not specified in the RDB options file, the default setting is OFF.

PDtable_201 items

SERVICE_LIMITS_TABLE = LIST, <prefix> If set to LIST, a list of Service Limits


Tables (as defined in the approved Piping Job Specification Table Library) is displayed. You
must specify a prefix to use as a substring search to determine the list of tables. (Use L for
the delivered tables.)
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
NOMINAL_PIPING_DIAMETER_TABLE = LIST, <prefix> If set to LIST, a list of
Nominal Piping Diameter Tables (as defined in the approved Piping Job Specification Table
Library) is displayed. You must specify a prefix to use as a substring search to determine the
list of tables. (Use D for the delivered tables.)
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
BRANCH_TABLE = LIST, <prefix> If set to LIST, a list of Branch Tables (as defined in
the approved Piping Job Specification Table Library) is displayed. You must specify a prefix to

Plant Design System (PDS) Reference Data Manager (PD_Data)

81

Piping Job Specification


be used as a substring search to determine the list of tables. (Use B for the delivered tables.)
The list is filtered to only include the unique tables, where the branch angle is 90 degrees.
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.

You should not assign the same Branch Table to be used in two different piping
materials classes if, for example, one allows intersections at both 45 degrees and 90 degrees,
and the other only allows 90 degree intersections. The Reference Data Manager will not
detect this problem.
TAP_PROPERTIES_TABLE = KEYIN or DATABASE If set to DATABASE, a list of Tap
Properties Data Tables (as defined in PDtable_205 of the unapproved Material Reference
Database) is displayed.
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
GASKET_SEPARATION_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of
Gasket Separation Tables (as defined in the approved Piping Job Specification Table Library)
is displayed. You must specify a prefix to be used as a substring search to determine the list
of tables. (Use G for the delivered tables.)
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.

82

When listing the Gasket Separation Tables, the list of tables is restricted to unique
names, excluding the underbar (_) and the pressure rating value that follows. In other words,
the list of Gasket Separation Tables will not include the pressure rating (G001 instead of
G001_1500).
THICKNESS_DATA_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of
Thickness Data Tables (as defined in the approved Piping Job Specification Table Library) is
displayed. You must specify a prefix to be used as a substring search to determine the list of
tables. (Use T for the delivered tables.)
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
MATERIALS_DATA_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of
Materials Data Tables (as defined in the approved Piping Job Specification Table Library) is
displayed. You must specify a prefix to be used as a substring search to determine the list of
tables. (Use M for the delivered tables.)
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
FLUID_CODE = VALUE Specify a default fluid code value to be used for the piping materials
class.
If this keyword is not specified in the RDB options file, the default mode is that you do not
intend to define this data, unless you specify the name of a Fluid Code Table.
FLUID_CODE_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of Fluid Code
Tables (as defined in the approved Piping Job Specification Table Library) is displayed. You
must specify a prefix (such as FC) to be used as a substring search to determine the list of
tables.
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
MATERIALS_DESCRIPTION = KEYIN or LIST If set to LIST, a list of materials
descriptions (as defined in the approved Standard Note Library) is displayed.
If this keyword is not specified in the RDB options file, the default mode is to key in the value.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

BEND_DEFLECTION_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of Bend


Deflection Tables (as defined in the approved Piping Job Specification Table Library) is
displayed. You must specify a prefix to be used as a substring search to determine the list of
tables.
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
PIPE_LENGTH_TABLE = KEYIN or LIST, <prefix> If set to LIST, a list of Pipe Length
Tables (as defined in the approved Piping Job Specification Table Library) is displayed. You
must specify a prefix to be used as a substring search to determine the list of tables.
If this keyword is not specified in the RDB options file, the default mode is to key in the table
name.
STANDARD_NOTE = KEYIN or LIST If set to LIST, a list of standard notes (as defined in
the approved Standard Note Library) is displayed.
If this keyword is not specified in the RDB options file, the default mode is to key in the value of
the standard note.

PDtable_202 items

MODEL_CODE = KEYIN or LIST If set to LIST, a list of acceptable model codes


(determined by the commodity name) is displayed. (See keyword COMMODITY_NAME <===>
MODEL_CODES for more information.)
If this keyword is not specified in the RDB options file or the list of acceptable model codes is
not defined, the default mode is to key in the value.
VALVE_OPERATOR = KEYIN or LIST If set to LIST, a list of valve operator types (as
defined in the RDB options file) is displayed. (See keyword VALVE_OPERATOR_LIST for
more information.)
If this keyword is not specified in the RDB options file or the list of valve operator types is not
defined, the default mode is to key in the value.
PROMPT_FOR_TAP_ORIENTATION This keyword is used if you require that all (or some)
orifice flanges have two taps oriented 90 degrees apart. By default orifice taps are oriented
180 degrees apart on the outside diameter of the flange.
If this keyword is not included in the RDB options list, the relative tap orientation for two taps
will always be 180 degrees.
COMMODITY_NAME <===> MODEL_CODES This keyword precedes the list of associations
between commodity names and their acceptable model codes. This list must be defined to
use the LIST option for MODEL_CODE.
The association between a commodity name and the acceptable model codes for that
commodity name is defined as follows.
<commodity_name> = <model_code_A>,<model_code_B>, ...
6Q1C01 = GATSP, GAT, GATF, GATR
6Q1C02 = GATEX, GATEXB, GATEXBB

You can define as many as 50 model codes, separated by a comma, for each commodity
name.
The delivered RDB options list includes a list of acceptable model codes for the reference
data provided with PDS.
VALVE_OPERATOR_LIST This keyword precedes the list of valve operator types and their
corresponding descriptions.
The list of valve operator types is defined as follows.

Plant Design System (PDS) Reference Data Manager (PD_Data)

83

Piping Job Specification


<valve operator type> = <description>
OP_0 = None Required
OP_3 = Handwheel

The delivered RDB options file includes a list of valve operator types for the reference data
provided with PDS. The description is for information only to aid the user in selecting the
proper valve operator type.
END_VALVE_OPERATOR_LIST This keyword must follow the valve operator list as a
delimiter.

Piping Materials Class Data Command


The Piping Materials Class Data command can be used to create a piping materials class
definition in Table 201 of the Material Reference Database or revise and existing piping materials
class definition.

Create The system activates the Create Piping Materials Class Data form.
Revise By Keyin The system activates the Revise Piping Materials Class Data form. Key
in the name of the piping materials class to revise in the Piping Materials Class field.
Revise By List Select the piping materials class to be revised from the displayed list of
piping materials classes (as defined in the Unapproved Material Reference Database) and
select Accept. The system activates the Revise Piping Materials Class Data form with the
data for the selected piping materials class.

Create/Revise Piping Materials Class Data


The Create/Revise Piping Materials Class Data form is used to create or modify the definition of a
piping materials class. When creating a new definition, the system will jump to the input fields for
the mandatory data. You must specify a value for all the mandatory fields.

84

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

The system highlights the mandatory input fields (those that must be specified). Once you define a
valid input for a mandatory field the system will drop the highlight for that field.
Refer to RDB Options File (on page 76) for information on defining list options for the applicable
input fields.
Refer to Piping Materials Class Data (201) (on page 45) for more information on the attributes for
the Piping Materials Class Data table (201).

Mandatory Input Fields

Piping Materials Class (keyin) Key in up to 16 alphanumeric characters for the piping
materials class to be defined. The system verifies that specified piping materials class does
not already exist in the Unapproved Material Reference Database.
Gasket Separation (keyin) Key in the value for the gasket separation for this piping
materials class.
OR
Gasket Table (keyin or list) Key in the table name or select from the list of tables (as
defined in the approved Piping Job Specification Table Library). The list of Gasket Separation
Tables will exclude the pressure rating value.
Service Limits (keyin or list) Key in the name of the Service Limits Table for this piping
materials class or select from a list of Service Limits Tables (as defined in the approved Piping
Job Specification Table Library).
Diameter (keyin or list) Key in the name of the Nominal Piping Diameter Table for this
piping materials class or select from a list of Nominal Piping Diameter Tables (as defined in the
approved Piping Job Specification Table Library).

Plant Design System (PDS) Reference Data Manager (PD_Data)

85

Piping Job Specification

Branch Table (keyin or list) Key in the name of the Branch Table for this piping materials
class or select from a list of Branch Tables (as defined in the approved Piping Job
Specification Table Library). The list will only include the unique tables, where the branch
angle is 90 degrees. For more information, see Bends and Tee-type Branches and Branch
Components in Piping Design Reference Guide.

The 90 degree button only works if a Branch Table exists.


You should not assign the same Branch Table to two different piping materials classes if,
for example, one allows intersections at both 45 degrees and 90 degrees, and the other
only allows 90 degree intersections. The Reference Data Manager will not detect this
problem.
You can place components without a Branch Table; you simply select the components
using the individual component buttons.
The Branch Table is the primary choice for picking branching components because of the
engineering calculations required.
Sometimes you can override the Branch Table based on company rules or the Stress
Group requirement. For example, the Branch Table can be overridden by not selecting
the 90 degree button and then selecting any other branching component. However, doing
so without direction from the rules or the Stress Group is a violation on the codes or
standards.
Tap Data (keyin or list) Key in the name of the Tap Properties Data Table for this piping
materials class or select from a list of Tap Properties Data Tables (as defined in PDtable_205
of the unapproved Material Reference Database).
The unapproved tap properties data is referenced, since all specification data within the
Material Reference Database is approved in one operation.

Optional Data - Wall Thickness


This data is required for piping commodities, where the schedule or thickness is not explicitly
defined in the piping materials class or in a wall thickness table.
Corrosion Allowance (keyin) Key in a numeric value, if wall thickness calculations are to
be used.
Thickness Equation (list) Select one of the displayed wall thickness equations.
ANSI B31.3-1987
EL01
ANSI B31.1a-1986 EJ01

The corresponding name for the thickness equation is loaded into the Piping Materials Class
Data Table.
Thickness Table (keyin or list) Key in the name of the Thickness Data Table for this piping
materials class or select from a list of Thickness Data Tables (as defined in the approved
Piping Job Specification Table Library).
Materials Data Table (keyin or list) Key in the name of the Materials Data Table for this
piping materials class or select from a list of Materials Data Tables (as defined in the approved
Piping Job Specification Table Library).

Optional Data
The following data is not required and can be defined or not defined based on your company
practices.

86

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Materials Description (keyin or list) Key in the numeric value for the materials description
in the Standard Note Library for this piping materials class or select from the list of materials
descriptions (as defined in the approved Standard Note Library).
Revision (keyin) Key in up to two alphanumeric characters for the revision number.
Revision Date (keyin) Key in up to ten alphanumeric characters for the date. The
current date will not be entered automatically.
Note that the Reference Data Manager creates and maintains a separate revision
management date on the basis of the current date and time which can be used in the reporting
of reference data.
Fluid Code (keyin list) Define a default fluid code to be used for the piping materials class.
OR
Fluid Code Table (keyin list) Key in the name of the Fluid Code Table for this piping
materials class or select from a list of Fluid Code Tables (as defined in the approved Piping
Job Specification Table Library).
Materials of Construction (keyin) Key in up to six alphanumeric characters.
Bend Deflect Table (keyin or list) Key in the name of the Bend Deflection Table for this
piping materials class or select from a list of Bend Deflection Tables (as defined in the
approved Piping Job Specification Table Library).
Pipe Length Table (keyin or list) Key in the name of the Pipe Length Table for this piping
materials class or select from a list of Pipe Length Tables (as defined in the approved Piping
Job Specification Table Library).
Standard Note Number (keyin or list) Key in the note number in the Standard Note
Library for this piping materials class or select from the list of standard notes (as defined in the
approved Standard Note Library).

Piping Commodity Data Command


The Piping Commodity Data command can be used to create a piping commodity definition in
Table 202 of the Material Reference Database or revise an existing piping commodity definition.

Create Select the Piping Materials Class for the commodity item to be created from the list
of piping materials classes (as defined in the Unapproved Material Reference Database) and
select Accept. The system activates the Create Piping Commodity Specification Data form.
Revise By Keyin Key in the name of the piping materials class for the commodity item to
be modified. Then select the piping commodity to be revised from the displayed List of Piping
Commodities and select Accept. The system activates the Revise Piping Commodity
Specification Data form with the data for the selected piping commodity.

Plant Design System (PDS) Reference Data Manager (PD_Data)

87

Piping Job Specification


Revise By List Select the piping materials class for the commodity item to be revised from
the displayed list of piping materials classes and select Accept. Then select the piping
commodity to be revised from the displayed List of Piping Commodities and select Accept.
The system activates the Revise Piping Commodity Specification Data form with the data for
the selected piping commodity.
Copy You can use the Copy option in conjunction with the Revise options as a
cut-and-paste feature. This command requires that both the source piping materials class data
and the destination piping materials class have been created.
You can copy a complete piping materials class, including the piping commodity specification
data or selectively copy specific commodities. Select the option for the items to be copied.
Source and Destination Piping Materials Class - These are active fields that, when selected,
display the piping materials class list. Select the source piping materials class from the displayed
list, and then select Accept. Select the destination piping materials class from the displayed list
and select Accept.

Select All - This option copies the specification data for all piping commodities within the selected
source piping materials class to the specified destination piping materials class.
Select From List - Select the source piping materials class from the displayed list and select
Accept. Select the destination piping materials class from the displayed list and select Accept.
Then select the piping commodity to be copied from the list of all piping commodities within the
source piping materials class.
Select Gaskets - Select the source piping materials class from the displayed list and select
Accept. Select the destination piping materials class from the displayed list and select Accept.
The system copies the specification data for all gaskets within the source piping materials class to
the destination piping materials class. Gaskets are recognized on the basis of the gasket
commodity name, as specified through the Project Data Manager.
Select Bolts - Select the source piping materials class from the displayed list and select Accept.
Select the destination piping materials class from the displayed list and select Accept. The
system copies the specification data for all bolts within the source piping materials class to the

88

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


destination piping materials class. Bolts are recognized on the basis of the bolt commodity
name, as specified through the Project Data Manager.
Short Commodity Material Description ON/OFF You can set this toggle to ON to verify
that the material description for a specified commodity code has been defined in the Short
Material Description Library.
Long Commodity Material Description ON/OFF You can set this toggle to ON to verify
that the material description for a specified commodity code has been defined in the Long
Material Description Library.

If the Material Description toggle is set to ON and no corresponding material description is found
for a specified commodity code, the system activates the Add Entry to Material Description Library
form. See Add Entry to Material Description Library (on page 95).

Create/Revise Piping Commodity Specification Data


The Create/Revise Piping Commodity Specification Data form is used to create or modify the
definition of a piping commodity within a specified piping materials class. When creating a new
definition, the system will jump to the input fields for the mandatory data. You must specify a value
(by keyin or selection from a list) for all the mandatory fields.

Refer to RDB Options File (on page 76) for information on defining options for the applicable input
fields.
Refer to Piping Commodity Specification Data (202) (on page 48) for information on the attributes
for the Piping Commodity Specification Data table.
Where possible, the system verifies that the specified value is valid for the applicable piping
materials class. For example, NPD values are checked against the associated diameters table in
the approved Piping Job Spec Table Library.
Commodity Type This field can be used to select the type of piping commodity data to be
created based on the settings in Standard Note Type 990 of the Standard Note Library.
General Fittings

Piping

Pipe Bends

Tubing

Plant Design System (PDS) Reference Data Manager (PD_Data)

89

Piping Job Specification


Orifice Flanges

Gaskets

Branch Nipples

Bolts

Branch Reinforcement

Nuts

Valves
The system will modify the form fields to reflect the data that is specific to that type of
component. The system stores the commodity type as the input_form_type within the Piping
Commodity Specification Data Table of the Material Reference Database.
Any input fields that are not used for a specific piping commodity type will be de-activated.
The General Fittings category will allow input in all the input fields. This form is used for any
piping commodity that does not fall within any of the other types.

General Fittings, Pipe Bends, Orifice Flanges, Branch Nipples, Branch Reinforcement, and
Valves
Commodity Name (keyin)
From NPD - First Size (keyin)
To NPD - First Size (keyin)
End Preparation - First Size (list)
Pressure Rating - First Size (keyin) This data is automatically set to undefined (blank)
for the branch reinforcement commodity type.
Table Suffix - First Size (list)
Schedule/Thickness - First Size (list) Attribute 10. This data is automatically set to
undefined (blank) for the branch reinforcement commodity type.
Commodity Code (keyin) Key in the commodity code for the piping commodity. When
size-dependent commodity codes are required, this will represent a system commodity code
and will be used by the Report Manager to reference the size-dependent commodity code in
the Piping Commodity Size-Dependent Material Data Table.
The system automatically translates the specified commodity code to be upper-case.
You can use the Implied Data option to specify implied data for this piping commodity. Refer
to Commodity Implied Data Command (on page 104) for information on project-specific
implied data. Refer to Implied Data (on page 94) for information on class-specific implied
data. The default is that implied data does not apply.
For the revise command, the prefixes for implied data are not displayed as part of the
commodity code, although the prefix will be loaded in the database. For implied data
(project-wide or class-specific), the system will display the toggle setting rather than showing
the prefix in the commodity code field.
Model Code (keyin or list) Attribute 19. Key in the model code or select the model code
from a list of acceptable model codes (as defined by commodity name in the RDB options file).
Geometric Industry Standard (list)
Weight Code (list)
fabrication category (list)
Define the following data for any reducing components. This data will not apply to either the
orifice flange or branch nipple commodity type.
From NPD - Second Size (keyin) Attribute 12. Key in the lowest second size for which
this specification data applies.
To NPD - Second Size (keyin) Attribute 13. Key in the highest second size for which this
specification data applies.

90

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


You can optionally define the following fields when two ends of that component require different
data. By PDS convention, if you specify a red End Preparation, you must specify the
corresponding pressure rating, table suffix, and schedule/thickness.
End Preparation - Second Size (list)
Pressure Rating - Second Size (keyin) This data is set to undefined (blank) for the
branch reinforcement commodity type.
Table Suffix - Second Size (list)
Schedule/Thickness - Second Size (list) This data is set to undefined (blank) for the
branch reinforcement commodity type.
The following data must be defined for the designated [component types]. The setting is stored in
the modifier attribute.
Bend Radius (keyin) [Pipe Bend] Key in the bend radius for the pipe bend.
Number of Taps (toggle) [Orifice Flanges] Set the toggle for the number of taps (1 or 2)
on the orifice flange. If applicable, set the orientation of the taps as 90 degrees or 180
degrees. This toggle only appears for orifice flanges that have two taps.
Nipple Length (keyin) [Branch Nipples] Key in length of the branch nipple.
Reinforcement Data (toggle) [Branch Reinforcement] Set the toggle for the source of
the branch reinforcement data to By System or By User.
If you select the by user branch reinforcement option, the commodity option code is
automatically defined with a value of 699 (User-defined), as required by PDS.
Valve Operator (keyin or list) [Valves] Key in the valve operator type or select the valve
operator type from a list of valve operator types. The list of valve operator types and the
corresponding descriptions are defined in the RDB options list.
Valve Operator Display (toggle) [Valves] Set the toggle to ON or OFF to determine
whether the valve operator is displayed in the model.
Modifier (keyin) You can define this value for specific piping commodities not covered by
the previous list.
You can define the following optional data depending on your requirements.
Commodity Option (list) Attribute 4.
Max Temperature (keyin) Attribute 5. If no value is specified, the default value
(undefined) is assigned automatically.
Materials Grade (list) Attribute 25.
Standard Note Number (list) Attributes 26 and 27. Select the note for this commodity
from the list of standard notes defined in the approved Standard Note Library.
PDS Sort Code (keyin) Attribute 20. The specified value is automatically converted to
upper-case.

Specification Data for Piping


You must define the following data for piping. The piping commodity name is defined
automatically, as specified through the Project Data Manager.
From NPD - First Size (keyin)
To NPD - First Size (keyin)
End Preparation (list)
Pressure Rating (keyin)
Table Suffix (list)
Schedule/Thickness (list)
Joint Quality Factor (keyin) (For wall thickness calculations) In lieu of the
schedule/thickness, you can request that the wall thickness be computed automatically by the

Plant Design System (PDS) Reference Data Manager (PD_Data)

91

Piping Job Specification


system by specifying the joint quality factor for wall thickness calculations. The system
multiplies the joint quality factor by 100, add a *C prefix to designate that the default
calculation is to be used, and loads the value into the schedule/thickness column. For
example, if the joint quality factor is 0.95, this value will be '*C095'.
Note that this is not the joint quality factor that is to be used in the branch reinforcement
calculations.
Commodity Code (keyin)
Model Code (toggle) Set the toggle to By System (PIPE) or By User (*FPIPE).
Geometric Industry Standard (list)
Weight Code (list)
Fabrication Category (list)
You can optionally define the following data for piping.
End Preparation - Second Size (list)
Commodity Option (list)
Max Temperature (keyin)
E, Reinforcement (keyin) Define the joint quality factor (E) for piping for which branch
reinforcement calculations apply. The system multiplies the joint quality factor by 100 and
loads it in the modifier column.
This is not the joint quality factor that is to be used in the wall thickness calculations for the
piping.
Purchased Length (keyin) You can key in the purchased length of the piping in sub-units.
This value is stored in the PDS sort code attribute.
Materials Grade (list)
Standard Note Number (list)
End Preparation - Other (list)

Specification Data for Tubing


Define the following data for tubing. The tubing commodity name is defined automatically, as
specified through the Project Data Manager.
From NPD - First Size (keyin)
To NPD - First Size (keyin)
End Preparation - First Size (list)
Pressure Rating - First Size (keyin)
Table Suffix - First Size (list)
Schedule/Thickness - First Size (list)
Joint Quality Factor (keyin)
Commodity Code (keyin)
Geometric Industry Standard (list)
Weight Code (list)
Fabrication Category (list)
You can optionally define the following data for tubing.
End Preparation - Second Size (list)
Commodity Option (list)
Maximum Temperature (keyin)
E, Reinforcement (keyin)
Purchased Length (keyin)
Materials Grade (list)
Standard Note Number (list)
End Preparation - Other (list)

92

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Specification Data for Gaskets
Define the following data for gaskets. The gasket's commodity name is defined automatically, as
specified through the Project Data Manager. The system displays the active project's selection
of MTO options applicable to gaskets for reference.
From NPD - First Size (keyin)
To NPD - First Size (keyin)
End Preparation - First Size (list)
Pressure Rating - First Size (keyin)
Table Suffix - First Size (list)
Commodity Code (keyin)
Gasket Thickness (keyin) Key in the gasket thickness to be reported through the Report
Manager. This value is loaded into the modifier column.
You must define the following specification data for gaskets, when the alternate gasket search
option has been enabled for MTO through the Project Data Manager. Otherwise, the input fields
will be disabled.
Alternate End Preparation (list) Select from the list of end preparation values as defined
in the approved Standard Note Library.
Alternate Pressure Rating (keyin) Key in up to eight characters to define the pressure
rating.
Alternate Table Suffix (list) Select from the list of table suffix values as defined in the
approved Standard Note Library.
You can optionally define the following data on the basis of the user-specific requirements for
gaskets.
Commodity Option (list)
Max Temperature (keyin)
Fabrication Category (list)
Materials Grade (list)
Standard Note Number (list)

Specification Data for Bolts


You must define the following data for bolts. The bolt's commodity name is defined
automatically, as specified through the Project Data Manager. The system displays the active
project's selection of MTO options applicable to bolts for reference.
From NPD - First Size (keyin)
To NPD - First Size (keyin)
Pressure Rating - First Size (keyin)
Table Suffix - First Size (list)
Commodity Code (keyin)
Bolt Extension (keyin)
You can optionally define the following data on the basis of user-specific requirements for bolts.
Commodity Option (list)
Fabrication Category (list)
Materials Grade (list)
Standard Note Number (list)

Specification Data for Nuts


You must define the following data for nuts. The commodity name is defined automatically, as
specified through the Project Data Manager.

Plant Design System (PDS) Reference Data Manager (PD_Data)

93

Piping Job Specification


Max Temperature (keyin)
Commodity Code (keyin)
You can optionally define the following data on the basis of user-specific requirements for nuts.
Fabrication Category (list)
Materials Grade (list)
Standard Note Number (list)

List of Piping Materials Classes Form


This form displays when you click any of the following commands:
Select Piping Materials Class. For more information, see Discrimination Data Form (on page
298).
Create or Revise by List in the Piping Commodity Data Command. For more information, see
Piping Commodity Specification Data (PDtable_202) (see "Piping Commodity Data
Command" on page 87).
Select a Piping Materials Class by placing a data point over an entry in the list and selecting
Accept.

Implied Data
When defining a piping commodity, you can select the Implied Data option to indicate that the
commodity will have an associated implied item that will be included in MTO reports. After
selecting the option, set the toggle to Class Specific.
This option is intended for implied components that are not unique within the project. A lap-joint
flange is an example of the primary component, where the stub-end is the implied component.
Refer to Commodity Implied Data Command (on page 104) for information on Project Specific
implied data.
When you select Accept to define a primary component, the system modifies the form display to
allow you to define the specification data for the implied component.

94

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


When you accept the specification data for the implied component, the system prefixes an asterisk
(*) to the commodity code of the primary component to indicate that implied data is present.
The following specification data for the implied component are determined by the corresponding
data for the primary component. This data is displayed in review only fields.
Commodity Name Same as the primary component.
Commodity Option The commodity option code for the implied component is set to the
primary component's commodity option code plus 5000.
From NPD same as the primary component.
To NPD same as the primary component.
Model Code same as the primary component.
You can optionally define the following specification data for the implied component based on your
reporting requirements. The values for the implied component default to the corresponding
values for the primary component, except for the commodity code.
End Preparation (list)
Pressure Rating (keyin)
Table Suffix (list)
Schedule/Thickness (list)
Commodity Code (keyin) Key in the commodity code for the implied item. The system
converts this value to upper-case.
When size-dependent commodity codes are required, this will represent a somewhat arbitrary
value, referred to as the system commodity code, and will be used by the Report Manager to
reference the size-dependent commodity code.
Geometric Industry Standard (list)
Weight Code (list)
Fabrication Category (list)
Modifier (keyin)
Max Temperature (keyin)
Materials Grade (list)
Standard Note Number (list)
PDS Sort Code (keyin) (optional). The system converts the value to upper-case.

Add Entry to Material Description Library


This form is used to define the material description for a specified commodity code in the
appropriate Material Description Library (short, long, or specialty). Refer to Material Description
Data (on page 269) for more information on material descriptions.

Requirements
The Material Description toggle must be set to ON.
If you have defined size-dependent commodity codes, this option will be ignored, unless both of
the following conditions are met:
The option for MTO to use the system commodity code to reference the material description
has been enabled through the Material Takeoff Options of the Project Data Manager.
The material descriptions have been created with embedded commodity code labels as the
means of inserting the size-dependent data into the material description.

Plant Design System (PDS) Reference Data Manager (PD_Data)

95

Piping Job Specification

Description Key in the material description for the specified commodity code and select
Accept.
The system adds the specified entry to the Material Description Library.

Piping Specialty Data Command


The Piping Specialty Data command can be used to create a piping specialty definition in Table
203 of the Material Reference Database or revise an existing piping specialty definition. You can
also add specialty descriptions to the Material Description Library.

96

Create Select the type of specialty (Piping Specialty or Valves) from the list. Then key in
the component number for the specialty item to be created and select Accept. The system
activates the Create Piping Specialty Specification Data form.
Revise By Keyin Key in the component number of the specialty to be modified and select
Accept. The system activates the Revise Piping Specialty Specification Data form with the
data for the selected piping specialty.
Revise By List Select the piping specialty to be revised from the displayed List of Piping
Commodities and select Accept. The system activates the Revise Piping Specialty
Specification Data form with the data for the selected piping specialty.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Specialty Material Description You can set this toggle to ON to verify that the material
description for a specified commodity code has been defined in the Specialty Material
Description Library.

If no corresponding material description is found, the system activates the Add Entry to
Material Description Library form. See Add Entry to Material Description Library (on page
95).

Create/Revise Piping Specialty Specification Data


The Create/Revise Piping Specialty Specification Data form is used to create or modify the
definition of a piping commodity within a specified piping materials class. When creating a new
definition, the system will jump to the input fields for the mandatory data. You must specify a value
(by keyin or selection from a list) for all the mandatory fields.

Refer to RDB Options File (on page 76) for information on defining options for the applicable input
fields.
Refer to Piping Specialty Specification Data (203) (on page 56) for information on the attributes for
the Piping Specialty Specification Data table.

Mandatory Input Fields

Piping Component Number (keyin) Key in the piping component number, which
uniquely identifies the piping specialty. The system verifies that the piping component number
does not already exist in the Unapproved Material Reference Database.
From NPD - First Size (keyin) Key in the first size value for the piping specialty. Both the
from and to values are loaded on the basis of this input.

Plant Design System (PDS) Reference Data Manager (PD_Data)

97

Piping Job Specification


To NPD - First Size (keyin) Key in the first size value for the piping specialty. Both the
from and to values are loaded on the basis of this input. The TO NPD field is only visible if an
applicable specialty type is selected.
End Preparation - First Size (list) Select from the list of end preparation values as
defined in the approved Standard Note Library.
Pressure Rating - First Size (keyin) Key in up to eight characters to define the pressure
rating.
Table Suffix - First Size (list) Select from the list of table suffix values as defined in the
approved Standard Note Library.
Schedule/Thickness (list) Select from the list of schedule/thickness values as defined in
the approved Standard Note Library.
Model Code (keyin) Key in the model code to be used to parametrically define the piping
specialty.
Physical Data ID (keyin) Key in the ID to be used as an arbitrary index into the geometric
data table for piping specialties.
Sort Code (keyin) Key in the sort code to be used as an arbitrary index into the geometric
data table for piping specialties. The system will convert the value to upper-case.
Fabrication Category (list) Select from the list of fabrication category values as defined
in the approved Standard Note Library.
You must define the following data for any reducing component.
NPD - Second Size (keyin) Key in the second size value for the piping specialty. Both
the from and to values are loaded on the basis of this input.
You must define the following data for valves. This data is stored in the modifier attribute.
Valve Operator (keyin or list) Key in the valve operator type or select the valve operator
type from a list of valve operator types (as defined in the RDB options file).
Valve Operator Display ON/OFF (toggle) Set the toggle to determine whether the valve
operator will be displayed in the model.
Specialty Type (field) This field can be used to select the type of piping specialty data to
be created based on settings in Standard Note Type 990 of the Standard Note Library. Place
a data point in this field to activate the Spec Writer Data Form Type pick list, then select the
preferred data type.

The system stores the specialty type as the input_form_type within the Piping Specialty Data
Table as a code-listed attribute for Standard Note Type 990.

Optional Input Fields


You can optionally define the following data, when two ends of the component require different
data. By PDS convention, if you specify the red end preparation, you must specify the
corresponding pressure rating, table suffix, and schedule/thickness.

98

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


End Preparation (list)
Pressure Rating (keyin)
Table Suffix (list)
Schedule/Thickness (list)
You can optionally define the following data depending on you requirements for piping specialties.
Weight Code (list)
Geometric Industry Standard (list)
Modifier (keyin)
Materials Grade (list)
Standard Note Number (list)

Instrument Data Command


The Instrument Data command can be used to create an instrument definition in Table 204 of the
Material Reference Database or revise an existing instrument definition. You can also add
descriptions to the Material Description Library.

Create Select the type of instrument (Instruments or Valves) from the list. Then key in the
component number for the instrument to be created and select Accept. The system activates
the Create Instrument Specification Data form.
Revise By Keyin Key in the component number of the instrument to be modified and select
Accept. The system activates the Revise Instrument Specification Data form with the data for
the selected instrument.
Revise By List Select the instrument to be revised from the displayed List of Instruments
and select Accept. The system activates the Revise Instrument Specification Data form with
the data for the selected instrument.
Specialty Material Description You can set this toggle to ON to verify that the material
description for a specified commodity code has been defined in the Specialty Material
Description Library.

If no corresponding material description is found, the system activates the Add Entry to
Material Description Library form. See Add Entry to Material Description Library (on page 95).

Plant Design System (PDS) Reference Data Manager (PD_Data)

99

Piping Job Specification

Create/Revise Instrument Specification Data


The Create/Revise Instrument Specification Data form is used to create or modify the definition of
an instrument. hen creating a new definition, the system will jump to the input fields for the
mandatory data. You must specify a value (by keyin or selection from a list) for all the mandatory
fields.

Refer to RDB Options File (on page 76) for information on defining options for the applicable input
fields.
Refer to Instrument Component Specification Data (204) (on page 58) for information on the
attributes for the Instrument Specification Data table.
Instrument Component Number (keyin) Key in the component number, which uniquely
identifies the instrument. The system verifies that the component number does not already
exist in the Unapproved Material Reference Database.
From NPD - First Size (keyin) Key in the first size value for the instrument. Both the
from and to values are loaded on the basis of this input.
To NPD - First Size (keyin) Key in the first size value for the instrument. Both the from
and to values are loaded on the basis of this input. The TO NPD field is only visible if an
applicable instrument type is selected.
End Preparation - First Size (list) Select from the list of end preparation values as
defined in the approved Standard Note Library.
Pressure Rating - First Size (keyin) Key in up to eight characters to define the pressure
rating.
Table Suffix - First Size (list) Select from the list of table suffix values as defined in the
approved Standard Note Library.
Schedule/Thickness (list) Select from the list of schedule/thickness values as defined in
the approved Standard Note Library.

100

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Model Code (keyin) Key in the model code to be used to parametrically define the
instrument.
Physical Data ID (keyin) Key in the ID to be used as an arbitrary index into the geometric
data table for instruments.
Sort Code (keyin) Key in the code to be used as an arbitrary index into the geometric data
table for instruments. The system will convert the value to upper-case.
Fabrication Category (list) Select from the list of fabrication category values as defined
in the approved Standard Note Library.
You must define the following data for any reducing component.
NPD - Second Size (keyin) Key in the second size value for the instrument. Both the
from and to values are loaded on the basis of this input.
Instrument Type (field) This field can be used to select the type of instrument component
data to be created based on settings in Standard Note Type 990 of the Standard Note Library.
Place a data point in this field to activate the Spec Writer Data Form Type pick list, and then
select the preferred data type.

The system stores the specialty type as the input_form_type within the Piping Specialty Data
Table as a code-listed attribute for Standard Note Type 990.
You can optionally define the following data when two ends of the component require different
data. By PDS convention, if you specify the red end preparation, you must specify the
corresponding pressure rating, table suffix, and schedule/thickness.
End Preparation (list)
Pressure Rating (keyin)
Table Suffix (list)
Schedule/Thickness (list)
You must define the following data for valves. This information is stored in the modifier attribute.
Valve Operator (keyin or list) Key in the valve operator type or select the valve operator
type from a list of valve operator types (as defined in the RDB options file).
Valve Operator Display ON/OFF (toggle) Set the toggle to determine whether the valve
operator will be displayed in the model.
You can optionally define the following data depending on your requirements for instruments.
Weight Code (list)
Geometric Industry Standard (list)
Modifier (keyin)
Materials Grade (list)
Standard Note Number (list)

Plant Design System (PDS) Reference Data Manager (PD_Data)

101

Piping Job Specification

Tap Properties Data Command


The Tap Properties Data command can be used to create a tap properties definition in Table 205
of the Material Reference Database or revise and existing tap properties definition.

Create Key in the name of the tap table to be defined. The system activates the Create
Tap Properties Data form.
Revise By Keyin Key in the name of the tap table to be modified. The system activates
the Revise Tap Properties Data form with the data for the selected tap table.
Revise By List Select the tap table to be revised from the displayed List of Tap Properties
Data (as defined in the Unapproved Material Reference Database) and select Accept. The
system activates the Revise Tap Properties Data form with the data for the selected tap table.

Create/Revise Tap Properties Data


The Create/Revise Tap Properties Data form is used to create or modify the specification data for
taps. When creating a new definition, the system will jump to the input fields for the mandatory
data. You must specify a value for all the mandatory fields.

Refer to RDB Options File (on page 76) for information on defining list options for the applicable
input fields.

102

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Refer to Tap Properties Data (205) (on page 61) for more information on the attributes for the Tap
Properties Data.
Tap Table Name (keyin) Key in up to six characters for the table name. The combination of
the tap properties table name, the tap nominal piping diameter, and the tap option code must be
unique.
Nom Piping Diameter (keyin) Key in the nominal piping diameter for this tap properties
definition.
Tap Option (list) Select from the list of tap option codes as defined in the approved
Standard Note Library. If you do not select a tap option code, the default value (one) is
assigned automatically.
End Preparation (list) Select from the list of end preparation values as defined in the
approved Standard Note Library.
Rating (keyin) Key in up to eight characters to define the pressure rating.
Schedule/Thickness (list) Select from the list of schedule/thickness values as defined in
the approved Standard Note Library.
Tap Material Code (keyin) During the tap properties data creation process, if the Short
and Long Commodity Description toggles are set to ON, you are allowed to insert Tap
Material Code data into the Short Material Description Library. This is the code that may
optionally be used by MTO for appending the tap's material description to that of the
component which has been tapped.
If you have defined size-dependent commodity codes, this option will be ignored, unless both
of the following conditions are met:
The option for MTO to use the system commodity code to reference the material
description has been enabled through the Material Takeoff Options of the Project Data
Manager.
The material descriptions have been created with embedded commodity code labels as
the means of inserting the size-dependent data into the material description.
This form is used to define the material description for a specified commodity code in the
appropriate (short) Material Description Library. Refer to Material Description Data (on page
269) for more information on material descriptions.

Plant Design System (PDS) Reference Data Manager (PD_Data)

103

Piping Job Specification

Key in the material description for the specified commodity code and select Accept. This code
must be a unique index into the project's Material Description Libraries.
The system converts the specified tap material code to upper-case, and then adds the specified
entry into the appropriate Material Description Libraries.

Commodity Implied Data Command


The Commodity Implied Data command defines the specification data for implied components in
Table 212 or the Material Reference Database. These implied components are reported by MTO
with the primary component in situations where the implied data is independent of the piping
materials class (used throughout the project).

104

Create Key in the system commodity code of the implied component to be created. The
system activates the Create Piping Commodity Implied Material Data form.
Revise By Keyin Key in the name of the piping materials class for the commodity item to
be modified. Then select the piping commodity to be revised from the displayed List of Piping
Commodities and select Accept. The system activates the Revise Piping Commodity
Specification Data form with the data for the selected piping commodity.
Revise By List Select the implied component definition to be revised from the displayed list
of Commodity Implied Data and select Accept. The system activates the Revise Piping
Commodity Implied Data form with the data for the implied component definition.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Create/Revise Piping Commodity Implied Material Data


The Create/Revise Piping Commodity Implied Material Data form is used to create or modify the
definition of an implied component. When creating a new definition, the system will jump to the
input fields for the mandatory data. You must specify a value (by keyin or selection from a list) for
all the mandatory fields.

Refer to RDB Options File (on page 76) for information on defining list options for the applicable
input fields.
Refer to Piping Commodity Implied Material Data (212) (on page 66) for more information on the
attributes for the Piping Commodity Implied Material Data table.
System Commodity Code Key in the commodity code for the primary component. The
system converts the value to upper-case.
For this type of implied data to be reported with the primary component, the specification data
for the primary component must have enabled the option in each piping materials class for
which this implied data applies.
From Diameter (First Size) Key in the lowest first size value for which this implied
specification data applies.
To Diameter (First Size) Key in the highest first size value for which this implied
specification data applies. The to value must equal or exceed the from value.
From Diameter (Second Size) For reducing components, key in the lowest second size
value for which this implied specification data applies. In cases where the piping commodity
represents both a full-size component and a reducing component, this value should equal the
corresponding first size NPD. Otherwise, for a reducing component, this value must be less
than the corresponding first size value.
To Diameter (Second Size) For reducing components, key in the highest second size
value for which this implied specification data applies. The to value must equal or exceed the
from value.

Plant Design System (PDS) Reference Data Manager (PD_Data)

105

Piping Job Specification

Commodity Code (keyin) During the commodity implied data creation process, if the
Short and Long Commodity Description toggles are set to ON, you are allowed to insert
Commodity Code data into the Short and Long Material Description Libraries.
If you have defined size-dependent commodity codes, this option will be ignored, unless both
of the following conditions are met:
The option for MTO to use the system commodity code to reference the material
description has been enabled through the Material Takeoff Options of the Project Data
Manager.
The material descriptions have been created with embedded commodity code labels as
the means of inserting the size-dependent data into the material description.
This form is used to define the material description for a specified commodity code in the
appropriate Material Description Library (short or long). Refer to Material Description Data
(on page 269) for more information on material descriptions.

Key in the material description for the specified commodity code and select Accept. This
code must be a unique index into the project's Material Description Libraries.
The system converts the specified commodity code to upper-case, then adds the specified
entry into the appropriate Material Description Libraries.
Quantity (keyin) Key in a whole number or a decimal value for the quantity of the implied
component per primary component.
Fabrication Category (list) Select from the list of fabrication category values as defined
in the approved Standard Note Library.
Standard Note Number (list) You can optionally select from the list of standard notes as
defined in the approved Standard Note Library.

Select a Piping Material Class commodity and click Accept.

106

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Table Checker
You can use the Table Checker option to perform on-line Table Checker validation for the defined
piping commodity specification data. When this option is enabled, table checker validation will be
performed for all piping commodities, except:
implied data specific to the piping materials class
gaskets
bolts
nuts
When you enable this option, the system displays a list of the defined Table Checker reports for
the project. Select the report validation to be performed and select Accept.

Refer to Table Checker Form (on page 293) for more information on creating a Table Checker
report definition.

Piping Job Specification Manager


This command enables you to load all of the database tables which make up the Piping Job
Specification portion of the Material Reference Database. You can also extract neutral files of the
data contained in the Material Reference Database.

Before Using This Command

Refer to the Project Administrator Reference Guide for information on creating a project and
creating the approved and unapproved Specification/Material Reference Database.
You must have installed the applicable reference database files (such as USRDB or DINRDB).
Use the Default Project Control Data option to set default settings for Piping Spec Path
and Piping Spec Node to point to the location of the neutral files. The default settings are
maintained in the Project Control Database.
You can also change these settings during the operation of the Piping Job Spec Manager.
However, such changes are temporary; they will not update the default locations.

Operating Sequence
1. Select the Piping Job Specification Manager option from the Reference Data Manager
form.

The system displays the Piping Job Specification Manager main form used to select the type of
Plant Design System (PDS) Reference Data Manager (PD_Data)

107

Piping Job Specification


data to process.

The data manipulation procedure for each of the database tables is similar. You can perform
the following activities for each of the entities.
2. Select Option
Select Unapprove ==> Approve to post the data from the unapproved Specification/Material
Reference Database to the approved database.

Accept to Create New Records or Exit


Toggle between Submit Immediately to submit the report for immediate processing, or
Delayed Submit to specify a time to submit the report for delayed processing.

108

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


When delayed submission is selected, you will be prompted Accept Time or Re-specify
Submit Time. Enter the day, hour, and minute, and then select AM or PM.
OR
Select the command for the database table to be loaded.

The system displays the options for the selected item. The following illustration reflects the
screen for Piping Materials Class.

Select Option
Select the option for the type of action to be performed.
Load, Replace, or Replace Commodity Subset (see "Load, Replace, or Replace Commodity
Subset Options" on page 110) from a neutral file.
Delete existing entries. For more information, see Delete Option (on page 112).
Report on the entity data (create a neutral file). For more information, see Report Option (on
page 112).
The manipulation procedure for each of type of piping data (listed below) is similar. See Piping Job
Specification Manager (on page 107).
Piping Material Class Data (Piping Materials Class Data (201) (on page 45))
Piping Commodity Data (Piping Commodity Specification Data (202) (on page 48))
Piping Specialty Data (Piping Component Tables for Specialty Components (on page 264))
Instrument Data (Instrument Component Specification Data (204) (on page 58))
Tap Properties Data (Tap Properties Data (205) (on page 61))
Size Dependent Material Data (Piping Commodity Size-Dependent Material Data (211) (on
page 64))
Project Implied Material Data (Piping Commodity Implied Material Data (212) (on page 66))
Component Insulation Exclusion Data (Component Insulation Exclusion Data (231) (on
page 69))
Flange Insulation Exclusion Data (Flange Insulation Exclusion Data (232) (on page 71))

Plant Design System (PDS) Reference Data Manager (PD_Data)

109

Piping Job Specification

Construction Tolerance Exclusion Data (Piping Construction Tolerance Exclusion Data


(233) (on page 73))
Pipe Support Group Data (Pipe Support Group Reference Data)
Pipe Support Commodity Data (Pipe Support Commodity Reference Data Table 241)
Pipe Support Material Data (Pipe Support Material Reference Data Table 242)
Pipe Support Material Description (Pipe Support Material Description Data Table 243)
Depending on the selected data, all or a few of the options below are available.
Load, Replace, or Replace Commodity Subset Options (on page 110)
Delete Option (on page 112)
Report Option (on page 112)

Load, Replace, or Replace Commodity Subset Options


These options enable you to load entries from a neutral ASCII file into the Material Reference
Database.
The Replace Commodity Subset option is only available for the Size Dependent
Material Data and Project Implied Material Data commands.
Refer to Material Reference Database Structure (on page 41) for a list of database tables and
neutral file formats used in defining the delivered PJS and material data.
Load adds the contents of the neutral file(s) to the information currently in that database table
of the Specification/Material Reference Database.
Replace deletes all entries in the respective database table and then loads new entries from
the neutral file.
Replace Commodity Subset revises (deletes and replaces) previously created
size-dependent or implied commodity data for a specific commodity or group of commodity
codes specified in a neutral file. This option is only available for the Size Dependent
Material Data and Project Implied Material Data commands.
The neutral files for the delivered USRDB data are in the directory
\win32app\ingr\rdusrdb\spec_data
classes.pmc the neutral file for the Piping Materials Class Data.
*.pcd The neutral files for the Piping Commodity Data are stored in a set of files of the
format pmcname.pcd. (For example, 1c0031.pcd defines all the commodity items for piping
materials class 1c0031.)
list.pcd a file that lists the neutral file names of all the delivered pcd files for the different
piping materials classes.
taps.data the neutral file for Tap Properties Data.
implied.data the neutral file for Project Implied Material Data.
A set of sample neutral files are delivered in the directory
\win32app\ingr\pddata\sample\data

specialty.data --- a sample neutral file for Piping Specialty Data.


instrment.data --- a sample neutral file for Instrument Data.
pcd_size.data --- a sample neutral file for Size Dependent Material Data.
You can copy the files and make changes before loading the information into the database.

Before Using This Command


You can define the variable PDS_COMMIT_INTERVAL= in the control.sh file to control the
commit interval in loading specification data into the Material Reference Database. This has the

110

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


same impact as adjusting the -c option in a risload command line. The default commit value is 25.
Increasing this variable may improve performance.

Operating Sequence
1. Select the Load/Replace (or other load or replace) option. See the description above for
differences in Load, Replace, and Replace Commodity Subset.
2. Specify Neutral File Name
Key in the file specification for the neutral file that contains the data to be copied.
For Piping Commodity Data, you can load or replace a single file or a list of files. To
process a list of files, create a list file which lists each neutral file on a separate line. The
file list.pcd contains a list of all the delivered neutral files.
For Size-Dependent or Implied Commodity Data, you can replace specific commodity
codes or all the entries in the database. To replace specific commodity codes, create a
neutral file which contains only the commodity codes to be replaced.
For the Load option, the system displays a dialog box to indicate that the data loaded will be
appended to existing data. Select Accept to continue.

3. Set the toggle to Submit Immediately or Delayed Submit.


For Delayed Submit, set the time to process the neutral file(s).
4. Accept to Create New Records or Exit
Select Accept to begin processing the request.
Job Has Been Submitted

The system submits the load/replace request as a batch job. Once the job is completed, the
system sends a mail message indicating the completion status of the load (successful or
unsuccessful).
The system also creates a set of log files in the \tmp directory.
pmc.log Piping Materials Class Data
pcd.log Piping Commodity Data
specialty.log Piping Specialty Data
instrument.log Instrument Data
taps.log Tap Properties Data
pcd_size.log Size-Dependent Material Data
implied.log Project Implied Material Data
These log files contain the following information.
The name of the neutral file being loaded
The completion status of the load (successful or unsuccessful)
The line number that caused the failure if the neutral file was not loaded.

Plant Design System (PDS) Reference Data Manager (PD_Data)

111

Piping Job Specification

Delete Option
This option enables you to delete entries from the Piping Job Specification.

Operating Sequence
1. Select the Delete option.

The system displays a list of all the items in the database for the selected class of data.

2. Select the item to be deleted from the database.


3. Accept to Delete Materials Class
Select Accept to begin deleting the data.

Report Option
The Report options enable you to create neutral files using the information in the
Specification/Material Reference database. The order and field lengths of the data in the neutral
file is determined by a format file named spec_order.max. This format file is expected to reside in
the same network address and directory specified for the report output. A default format file is
delivered with the PD_Data product in the file
\win32app\ingr\pddata\sample\format\spec_order.max. If the spec_order.max file is not found at
the specified output directory, the system will use the default spec order.
If an unapproved Specification/Material Reference database exists for the active project, you can
select the database to process: approved or unapproved.

Operating Sequence
1. Select the Report option from one of the data forms (such as the Piping Commodity Data
form).
For Piping Commodity Data, select the appropriate PCD from the list.

112

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


2. Specify Neutral File Name
Key in the name of the neutral file to be created. You can change the Node Name and File
Path information.
3. Set the toggle to Submit Immediately or Delayed Submit.
For Delayed Submit, set the time to process the neutral file(s).
4. Accept to Create Report
Select Accept to create the specified neutral file.
Job Has Been Submitted
The system creates the neutral file and a log file named specmgr.log.

Example spec_order.max File


!
! This file contains the spec attribute order and their maximum attribute
! lengths required for creating spec output neutral files. When creating
! spec reports the system will default an attribute order and set of
! attribute lengths. The user can edit these attribute orders and
! lengths in this file ( spec_order.max ). If this file is in the
! directory where the software is being run the orders defined in
! this file will be used as the default attribute order and lengths.
201 = 2,16 3,3 4,3 5,10 6,7 7,7 8,8 9,6 10,6 11,6 12,6 13,6 14,6 15,6 16,6
17,6 18,8 19,6 20,6
202 = 3,6 4,6 5,7 6,6 7,6 8,6 9,8 10,8 11,8 12,8 13,8 14,8 15,8 16,8 17,6
18,16 19,6 20,6 21,7 22,6 23,6 24,6 25,6 26,6 27,6
203 = 2,20 3,6 4,6 5,8 6,8 7,6 8,8 9,8 10,6 11,8 12,8 13,8 14,8 15,8 16,6
17,8 18,6 19,7 20,6 21,6 22,6 23,6 24,6 25,6
204 = 2,20 3,6 4,6 5,8 6,8 7,6 8,8 9,8 10,6 11,8 12,8 13,8 14,8 15,8 16,6
17,8 18,6 19,7 20,6 21,6 22,6 23,6 24,6 25,6
205 = 3,8 4,6 5,8 6,8 7,8 8,10
211 = 2,16 3,8 4,8 5,8 6,8 7,16 8,8 9,8 10,8
212 = 2,16 3,8 4,8 5,8 6,8 7,16 8,8 9,6 10,6

Plant Design System (PDS) Reference Data Manager (PD_Data)

113

Piping Job Specification

Piping Job Spec Report Manager


This command activates the Piping Job Spec Report Manager form. It is used to generate
reports from the Specification/Material Reference Database with the report definition data. The
Piping Job Spec Report Manager stores the report record and location records for each
discrimination data file and format file in the Project Control Database. The numbered records are
used to locate ASCII files on their specified nodes.

Report Format Displays the Report Format form, which you can use to create, revise,
copy, or delete the record of a format file (not the format file). For more information, see
Report Format Form (on page 116).
Report Discrimination Data Displays the Discrimination Data form, which you can use
to create, revise, copy, or delete the record of a discrimination data file as well as the file itself.
For more information, see Report Discrimination Data Form (on page 119).
Report Displays the Report form, which you can use to create, revise, delete, and approve
report records and report files. For more information, see Report Form (on page 125).
Report Management Data Displays the Report Management Defaults form, which you
can use to create a record in the project control database of the default nodename and path for
the report definition files. This option is primarily used for setup. For more information, see
Report Management Defaults Form (on page 133).

Using the Report Commands


Understanding Report Files and Records
The Piping Job Spec Report Manager uses the discrimination data files, format files, and
database records that represent these files to generate reports. The following definitions explain
all of the files and records in the reporting process.

114

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification


Format File and Record
The format file is a user-defined, ASCII file which must be created with a text editor outside of the
Piping Job Spec Report Manager. It contains special indices identifying what data appears in
the report and how the data is sorted. It also defines how the data is formatted in the report.
Without the format file(s), Piping Job Spec Report Manager reports cannot be processed. A
set of basic format files is delivered for each type of reporting.
Using the Report Format option, you can create a numbered record for each format file so that it
can be accessed for report processing. The format record is a record in the Project Control
Database used to name and locate a specific format file. Unlike the format file, the format record is
created interactively. It is called a record to classify it as a block of data that is used for report
processing but is not an actual file.

Discrimination Data File and Record


The discrimination data file limits the report to only the specified database occurrences. It is an
ASCII file that is created interactively using the Piping Job Spec Report Manager.
The discrimination data record is a record in the Project Control Database used to name and
locate a specific discrimination data file. There is a uniquely-numbered record for each
discrimination data file so that it can be accessed for report processing. This is the same way
that the format record is used to access a format file.

Report Output and Record


The Piping Job Spec Report Manager creates a report using the specified format,
discrimination, and search criteria data files, and places it in the specified directory on the
specified node.
The report record names or defines locations for all of the files that are necessary to generate a
report, including the report output. (It is called a record to classify it as a block of data that is used
for report processing but is not an actual file.)

Group Workflow
There is a definite workflow for at least the first time you create a report. First, use the Report
Management Data option to specify defaults for the nodename and path of the report definition
files. By defining the defaults first, you can prevent keying in a nodename and path on each form.
If you want to use a different nodename or path than the defined default, simply place a data point
in that field and key in the modification.
The following steps can be done in any order: create your format record, discrimination data
record, and discrimination data file using the Report Format and Report Discrimination Data
options. Reports cannot be generated until the format file, the discrimination data file, and their
corresponding records have been established.
Finally, use the Report option to create the actual report.

Plant Design System (PDS) Reference Data Manager (PD_Data)

115

Piping Job Specification

Report Format Form


When you select the Report Format option from the Piping Job Spec Report Manager form, the
Report Format form is displayed.

This form enables you to create, copy, revise, or delete a record of the location of the format file in
the project control database. An option is also provided that enables you to copy a record and its
corresponding ASCII format files.
The format file defines the data that will be reported and the way in which that data will be
displayed. Reports cannot be generated unless a format file exists and a record of the file's
location has been entered into the project control database.
Create Displays the Format Creation/Revision form, which enables you to add a new
record of a format file in the project control database. For more information, see Format
Creation/Revision Form (on page 117).
Copy Displays the Format Creation/Revision form, which copies the record of an existing
format file from the project control database along with the corresponding ASCII format file.
For more information, see Format Creation/Revision Form (on page 117).
Revise Displays the Format Creation/Revision form, which modifies a record of an
existing format file in the project control database. For more information, see Format
Creation/Revision Form (on page 117).
Delete Displays the Deletion form, which deletes an existing record of a format file from the
project control database. If the record of the format file is deleted, reporting cannot be
performed. For more information, see Format Deletion Form (on page 118).

116

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Format Creation/Revision Form


When you select Create, Copy, or Revise from the Report Format form, the Piping Job Spec
Report Manager form is displayed.

This form creates, copies, or revises a record in the project control database; this record defines
the location of a format file. The format file itself defines the contents and format of the report.
Both the location specification and the format file must exist to report on PDS data.
Number A unique number of up to 24 characters. Specifies the short name in the project
control database used to identify the record of the format file.
Description A description of up to 40 characters for the format file.
File Specification The file name of the format file to reference.
File Path The disk location of the format file. This field retains the active setting.
File Node The nodename of the system on which the format file is located. This field
retains the active setting.

Before Using this Form


You must have created an ASCII format file. A set of basic format files is delivered with the
PD_Report product in the win32app\ingr\pddata\sample\format directory. The file for Spec
Reporting reporting is named piping_rdb.fmt.
For a description of each of the delivered sample format files, see PDS Report Manager.

Operating Sequence
1. Select Create, Copy, or Revise.

A list of available records displays for copy or revision. To create a database record, go to
Step 3.
2. Select Report Format
3. From the displayed list, select the record to be copied or revised. Then select Accept.

Key-in fields are displayed for you to specify the required database information.
4. Specify Report Format Data
Type information in each of the displayed fields, taking care to press Enter in each field.
Then select Accept.

The project control database is updated.

Plant Design System (PDS) Reference Data Manager (PD_Data)

117

Piping Job Specification

Format Deletion Form


When you choose Delete, the Deletion form is displayed.

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

118

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Report Discrimination Data Form


When you select Report Discrimination Data from the Report Manager form, the
Discrimination Data form is displayed.

This form creates, copies, revises, and deletes a discrimination data file from the specified
directory. The associated record in the project control database is also copied, revised, or
deleted as needed.
A discrimination data file is an ASCII file that designates which models will be included in a report.
That is, discrimination data specifies the scope of the report. The project control database record
specifies the name and location of the discrimination data file that is to be associated with a
specific report.
Create Displays the Discrimination Data Creation form, which creates a new
discrimination data file. The associated project control database record is also created. For
more information, see Discrimination Data Creation Form (on page 120).
Copy Displays the Discrimination Data Revision form, which copies an existing data file.
The associated project control database record is also copied. For more information, see
Discrimination Data Revision Form (on page 122).
Revise Displays the Discrimination Data Revision form, which modifies discrimination
data. You can use this option to revise the contents of the discrimination data file, the
location of the discrimination file, and the associated record in the project control database.
For more information, see Discrimination Data Revision Form (on page 122).
Delete Displays the Deletion form, which deletes a discrimination data file as well as its
associated record in the project control database. For more information, see Discrimination
Data Deletion Form (on page 124).

Plant Design System (PDS) Reference Data Manager (PD_Data)

119

Piping Job Specification

Discrimination Data Creation Form

Commands

Approved Piping Job Spec Defines the database to be reported: approved or


unapproved.
Search Criteria Defines search criteria for specified attributes in the Specification/Material
Reference Database. For more information, see Search Criteria Form (on page 121).

Field Descriptions

120

Number --- Key in a unique number to name the discrimination data record to be created by
discrimination. The number can be up to 24 characters in the Project Control Database.
This number is a short name to identify the record of the discrimination data file.
Description --- Key in a description of the discrimination data file with up to 40 characters in
the Project Control Database.
File Specification --- Key in the filename of the discrimination data file to create.
The system verifies that the file does not already have a record in the project.
File Path --- Displays the disk location of the discrimination data file. This field retains the
active setting.
File Node --- Displays the nodename where the discrimination data file is located. This field
retains the active setting.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Search Criteria Form


You can define search criteria to restrict the elements to be reported based on database
attributes. The default is no search criteria. This option enables you to define search criteria for
specified attributes in the Spec Database.
If you do not restrict the piping materials class attribute for Piping Commodity Data, all
piping materials classes will be reported.

Operating Sequence
1. Select the Search Criteria option from the Discrimination Data form.

2. Select Entity
Select the database entity that contains the data to be restricted.

The system displays the attributes for the selected entity.

3. Select Attribute
Select the attribute to be restricted.

Plant Design System (PDS) Reference Data Manager (PD_Data)

121

Piping Job Specification


The system displays the selected attribute and displays a list of operators.

4. Select Operator
Select the required operator to define the search criteria.

The system displays the selected operator and prompts you to key in an attribute value.
5. Enter Attribute Value
Key in the attribute value. For a sub-string search, key in a string to appear anywhere within
the attribute value (do not use wild cards).
If the attribute is code-listed, the system displays a list of values from the standard note library.
Select the value and select Accept.

The system validates the input and displays the defined search criteria.
6. Accept or Select And/Or Operator.
Select AND to specify an additional condition or select OR to specify an alternative condition.

OR
Accept the defined search criteria.

Discrimination Data Revision Form


When you select Copy or Revise from the Discrimination Data form, the Discrimination Data
Revision form displays. This form enables you to copy or revise a discrimination data file from the
specified directory and its record from the Project Control Database. The copied discrimination
data file can then be modified.
First, the system displays the Record Number display list as shown below on the left. After you
select and Accept the discrimination data file you need, the system then displays the
discrimination data identification fields. These fields are used to define the record as shown
below.

122

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Commands

Approved Piping Job Spec Defines the database to be reported: approved or


unapproved.
Search Criteria Defines search criteria for specified attributes in the Specification/Material
Reference Database. For more information, see Search Criteria Form (on page 121).

Field Descriptions

Number Key in a unique number to name the discrimination data record with up to 24
characters in the Project Control Database. This number is a short name to identify the
record of the discrimination data file.
Description Key in a description of the discrimination data file with up to 40 characters in
the Project Control Database.
File Specification Key in the filename of the discrimination data file to reference.
The system verifies that the file does not already have a record in the project.
File Path Displays the disk location of the discrimination data file. This field retains the
active setting.
File Node Displays the nodename where the discrimination data file is located. This field
retains the active setting.
If prompted to...

Do this:

Select Discrimination Data

Select the record number of the discrimination data file to revise


and select Accept.

Specify Discrimination Data

Key in any changes to the discrimination data record displayed in


the information fields, and select as many of the Discrimination
Data options as necessary to define the discrimination data file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

123

Piping Job Specification

Discrimination Data Deletion Form


When you choose Delete, the Deletion form is displayed.

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

124

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Report Form
When you select Report from the Report Manager form, the Report form is displayed.

This form creates, revises, and deletes report records and report files. A report record holds
specifications for a report; these specifications include the report name, the report description, and
which format file, discrimination data file, and search criteria data file to use to generate a report.
The report name is not the title that is printed on the report; the title is included in the format
file.
At the end of each report, a parameters page is included that contains the following information:
Report Output The report number, report title, report creation/revision date, and report
node, path, and file name.
Format The report format number, description, and node, path, and file name.
Discrimination Data The report discrimination data number, description, and file location
(network address, path, and file name). The following discrimination data is also included: list
of model numbers (with discipline), volume (if applicable), search criteria (if applicable), and
sorting sequence.
Search Criteria The report search criteria number, description, and file location (node,
path, and file name. The following search criteria data is also included: list of model
numbers (with discipline), volume (if applicable), search criteria (if applicable), and sorting
sequence.

Options

Create Displays the Report Creation form, which creates a report record and generates a
report. For more information, see Report Creation Form (on page 126).
Revise Displays the Revise Report form, which regenerates a report from an existing or
revised report record. For more information, see Revise Report Form (on page 128).

Plant Design System (PDS) Reference Data Manager (PD_Data)

125

Piping Job Specification

Delete Displays the Deletion form, which deletes an existing report record and the
corresponding report. For more information, see Report Deletion Form (on page 130).
Approve Displays the Report Approval form, which approves an existing report. For
more information, see Report Approval Form (on page 131).
Multi-Create Displays the Report Multiple Submit form, which submits multiple reports to
the printer. For more information, see Report Multiple Submit Form (on page 131).

Report Creation Form


When you select Create from the Report form, the Report Creation form is displayed.

Use this form to create a report record and to generate a report. Because report records are stored
in the project control database, you can use them repeatedly.
Report Number The 24-character number that uniquely identifies the record of the report
file in the project control database. This is sometimes referred to as the report file short
name.
Report Title The 40-character descriptive name of the report file. This is not the title in the
actual report, but is rather the title of the report record. The title of the report is contained in
the format file.
Report File Spec The name of the report output file (up to 14 characters).
Report File Path The disk location for the report output file. This field retains the active
settings, and it is automatically populated if you have specified this data on the Report
Management Data form. For more information, see Report Management Defaults Form (on
page 133).
Report Node The name of the system on which the report output file will be located. This
field retains the active settings, and it is automatically populated if you have specified this data
on the Report Management Data form. For more information, see Report Management
Defaults Form (on page 133).

126

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Report Format File The name of the format file to be used to generate the active report.
When you select this field, a list of available format files is displayed. Select the appropriate
format file, and click Accept.
Report Discrimination File The name of the discrimination data file to be used to generate
the active report. When you select this field, a list of available discrimination data files is
displayed. Select the appropriate discrimination data file, and click Accept.
Report Search Criteria The name of the search criteria data file to be used to generate the
active report. When you select this field, a list of available search criteria files is displayed.
Select a search criteria file, and click Accept.
Select this field a second time to specify a different search criteria file. To clear a
specification, click Accept without selecting a file.
If the report discrimination data selected for the active report has search criteria data
defined within it, and you specify a search criteria in this field, the search criteria specified in
the Report Search Criteria field takes precedence over the search criteria contained in the
discrimination data.
Revision Number The revision number (up to three characters) for the report.
Last Revision Number The revision number of the last report generated. This is a
read-only field; you cannot edit it.
Revised By The user (up to five characters) who checked the report. This field is optional.
Revision Description The description (up to 40 characters) of the report revision. This
field is optional.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit Immediately/Submission is Delayed Specifies when the report will be
processed. When this toggle is set to Submission is Delayed, additional fields display for
you to specify the date and time that the report is to be generated.

Operating Sequence
1. From the Report form, select Create.

The Report Creation form is displayed.


2. Specify Report Data
Key in the report record information. Then select the appropriate report format file,
discrimination data file, and search criteria data file.
3. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
4. Specify whether the report is to be generated now (Submit Immediately) or later
(Submission is Delayed). If you choose delayed submission, specify the date and time that
the report is to be submitted.
5. Click Accept to save the report file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

127

Piping Job Specification

Revise Report Form


When you select Revise from the Report form, the Revise Report form is displayed.

This form revises an existing report record and generates a report from the project control
database. An option is also provided to update (in some cases) the report record without
generating a report output file. Similarly, you can choose to generate an updated report output
file without updating the report record.
Report Number The 24-character number that uniquely identifies the record of the report
file in the project control database. This is sometimes referred to as the report file short
name.
Report Title The 40-character descriptive name of the report file. This is not the title in the
actual report, but is rather the title of the report record. The title of the report is contained in
the format file.
Report File Spec The name of the report output file (up to 14 characters).
Report File Path The disk location for the report output file. This field retains the active
settings.
Report Node The name of the system on which the report output file will be located. This
field retains the active settings.
Report Format File The name of the format file to be used to generate the active report.
When you select this field, a list of available format files is displayed. Select the appropriate
format file, and click Accept.
Report Discrimination File The name of the discrimination data file to be used to generate
the active report. When you select this field, a list of available discrimination data files is
displayed. Select the appropriate discrimination data file, and click Accept.
Report Search Criteria The name of the search criteria data file to be used to generate the
active report. When you select this field, a list of available search criteria files is displayed.
Select a search criteria file, and click Accept.
Select this field a second time to specify a different search criteria file. To clear a
specification, click Accept without selecting a file.

128

If the report discrimination data selected for the active report has search criteria data
defined within it, and you specify a search criteria in this field, the search criteria specified in
the Report Search Criteria field takes precedence over the search criteria contained in the
discrimination data.
Revision Number The revision number (up to three characters) for the report.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Last Revision Number The revision number of the last report generated. This is a
read-only field; you cannot edit it.
Revised By The user (up to five characters) who checked the report. This field is optional.
Revision Description The description (up to 40 characters) of the report revision. This
field is optional.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit to Batch Immediately/Delayed Submit to Batch Specifies when the report will
be processed. When this toggle is set to Delayed Submit to Batch, additional fields display
for you to specify the date and time that the report is to be generated.
Revise Data Only/Revise Report and Data Specifies revision of the report data only
(Revise Data Only) or revision of the report data and the report output file (Revise Report
and Data). To revise the report specification without updating the report output file, make the
necessary changes, set this toggle to Revise Data Only, and click Accept. To revise the
report output file only, set this toggle to Revise Report and Data without modifying any of the
fields, and click Accept. To modify both the report file and the report output file, make the
necessary changes, set this toggle to Revise Report and Data, and click Accept.
If you update any field other than Report Number and Report Title, this toggle is
automatically set to Revise Report and Data, and the report output file is generated.

Operating Sequence
1. From the Report form, select Revise.

The Report Creation form is displayed with a list of available report files.
2. Select Report
From the displayed list, select the report to be revised. Then click Accept.

The fields update to display the selected report file specifications.


3. Revise Report Information
Update the report record information as needed.
4. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
5. Specify whether the report is to be generated now (Submit Immediately) or later
(Submission is Delayed). If you choose delayed submission, specify the date and time that
the report is to be submitted.
6. Click Accept to save the report file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

129

Piping Job Specification

Report Deletion Form


When you choose Delete, the Deletion form is displayed.

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

130

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Report Approval Form


When you select Approve from the Report form, the Report Approval form is displayed.

Use this form to select a report to approve. Approving a report means that a database attribute is
set from not approved (the default) to approved. This approval status provides a way for you to
flag reports that you have run and verified that the output data is valid. When a report is revised,
the approval status is automatically reset to not approved.
Number The 24-character unique name (also called short name) of the report record.
Description The 40-character description of the report record.

Operating Sequence
1. From the Report form, select Approve.

The Report Approval form is displayed.


2. From the displayed list, select a report to approve. Then click Accept.

The Approval form is displayed.


For more information, see the PD_Report User's Guide.

Report Multiple Submit Form


When you select Multi-Create from the Report form, the Report Multiple Submit form is
displayed.

Plant Design System (PDS) Reference Data Manager (PD_Data)

131

Piping Job Specification

Use this form to submit multiple reports at the same time.


Number The 24-character number that uniquely identifies the record of the report file in the
project control database. This is sometimes referred to as the report file short name.
Description The 40-character descriptive name of the report file.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit to Batch Immediately/Delayed Submit to Batch Specifies when the report will
be processed. When this toggle is set to Delayed Submit to Batch, additional fields display
for you to specify the date and time that the report is to be generated.

Operating Sequence
1. From the Report form, select Multi-Create.

The Report Multiple Submit form is displayed.


2. Select Reports for Submission
From the displayed list, select the reports to submit. Highlighted reports are selected; select a
highlighted report to remove the highlight and to not submit the report.
3. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
4. Specify whether the report is to be generated now (Submit to Batch Immediately) or later
(Delayed Submit to Batch). If you choose delayed submission, specify the date and time
that the report is to be submitted.
5. Click Accept to submit the reports.

132

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification

Report Management Defaults Form


When you select Report Management Data from the Report Manager form, the Report
Management Defaults form is displayed.

This form creates a record in the project control database of the node name and path of the report
definition files. This option is used primarily for setup.
Report Path Specifies the default path of the report output files.

It is recommended that you not send output reports to your system's temporary (that is,
tmp or temp) directory.
Report Node Specifies the default node name of the system on which report output files
are located.
Report Format Path Specifies the default path of the format files.
Report Format Node Specifies the default node name of the system on which format files
are located.
Report Discrimination Data Path Specifies the default path of the discrimination data
files.
Report Discrimination Data Node Specifies the default node name of the system on
which discrimination data files are located.
Report Search Criteria Data Path Specifies the default path of the report search criteria
data files.
Report Search Criteria Data Node Specifies the default node name of the system on
which report search criteria data files are located.

Operating Sequence
1. From the Report Manager form, select Report Management Data.

The Report Management Defaults form is displayed.

Plant Design System (PDS) Reference Data Manager (PD_Data)

133

Piping Job Specification


2. Accept or Exit
In the fields provided, key in the default paths and node names for the report output files,
format files, discrimination data files, and search criteria data files. Then click Accept.

134

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 7

Piping Job Specification Tables


Nonphysical data such as branch calculations or gasket separation are stored in the Spec Table
Library or hard-coded in the system. The Spec Tables for US practice are delivered in the
following files:
\win32app\ingr\rdusrdb\us_pjstb.l - object library
\win32app\ingr\rdusrdb\us_pjstb.l.t - text library
These libraries contain the Piping Job Specification tables and the other special tables which
contain nonphysical data.
The data in the Spec Table Library falls into two basic categories.
Specification Tables - Referenced in the Piping Materials Class Specification Data of the
Material Reference Database. For more information, see PJS Tables and Functions (on
page 135).
RDB Tables - Referenced in the Component Placement and Material TakeOff forms of the
Project Data Manager. For more information, see RDB Tables (on page 155).
You can use the Piping Job Specification Tables command to create a new Piping Job
Specification Table library or to create, modify, or delete tables in an existing library. For more
information, see Piping Job Specification Tables Command (on page 173).
Piping Job Specification Table files are limited to a file size of approximately 60,000 bytes
or 750 rows.

PJS Tables and Functions


The following special tables and functions are provided in the Spec Table Library. These
table/equation names are defined in the Piping Materials Class Specification Table of the
Specification Material Reference Database.
Temperature and Pressure Service Limits Table (on page 136)
Nominal Piping Diameter Table (on page 137)
Thickness Data Tables (on page 140)
Materials Data Table (on page 142)
Wall Thickness and Branch Reinforcement Equations (on page 152)
Branch Insertion Tables (on page 145)
Gasket Separation Table (on page 149)
Fluid Code Table (on page 151)

Plant Design System (PDS) Reference Data Manager (PD_Data)

135

Piping Job Specification Tables

Temperature and Pressure Service Limits Table


The temperature and pressure service limits table includes the sets of temperatures and
pressures that define the boundaries of acceptability for a piping materials class. These limits
can be dictated by factors such as strength of components and materials used. You must insure
that each of the components included in the piping materials class meet the indicated temperature
and pressure limits.
You can define both positive and negative values for temperature. However, you can only define
positive values for pressure. The units of measure for the pressure and temperature values in the
table are defined as a part of the table description.
The system uses the information in this table to insure:
The highest temperature from the TDB does not exceed the highest temperature value in the
table
The lowest temperature in the TDB is not less than the lowest value in the table
For a given temperature, the pressure from the table is not less than any of the corresponding
pressure(s) from the TDB.
This table is limited to 100 temperature and pressure values.

Neutral File Format


Table_Data_Definition 'LWWWW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 1
Input_Interpolation 1, Next_One
Units= DF, PSIG
! Temperature Pressure
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
WWWW
ZZZZZZ
END

Example
Table_Data_Definition 'L1001'
! Description= B16.5 CL150-1.1, -20 to 800
! By=DCG
Ckd By=DG
Rev=0
No_Inputs 1 No_Outputs 1
Input_Interpolation 1, Next_One
Units= DF, PSIG
! Temperature Pressure
-20
285
100
285
200
260
300
230
400
200
500
170

136

Date=13-Feb-1987

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


600
650
700
750
800
END

140
125
110
95
80

Parameters

Table_Data_Definition (character-6) This parameter specifies the name of the


Temperature and Pressure Service Limits Table. These tables use the following naming
conventions.
first character: L
second character: the pressure rating of the piping materials class as defined by the
following code:
1= CL150

8= GRAVHD

K= CL5000

2= CL300

9= OTHER

L= CL6000

3= CL400

A= CL125

M= CL9000

4= CL600

F= CL800

N= CL10000

5= CL900

G= CL2000

R= CL15000

6= CL1500

H= CL3000

T= CL20000

7= CL2500
J= CL4500
V= CL30000
third, fourth, and fifth characters: numbers from 001 through 999 used to make the table
name unique.
Input_Interpolation 1, Next_One This statement tells the system to interpolate between
known values for the temperature value. The statement must be included as shown in the
table format for the desired interpolation to take place.
Temperature (real) This field identifies the maximum temperature value. You can use
both positive (+) and negative (-) values. Values are assumed to be positive unless
otherwise indicated.
Pressure
(real) This field identifies the value for pressure corresponding to the
previously defined temperature. Negative (-) values are not accepted in this field.

Nominal Piping Diameter Table


The NPD Table consists of the diameters for piping and tubing which are valid within any piping
materials class which references this table. The system verifies any NPD input in the Piping
Design TDB.

Neutral File Format


Table_Data_Definition 'DWWW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 0
Units= NPD_IN
! Diam
WWWWW

Plant Design System (PDS) Reference Data Manager (PD_Data)

137

Piping Job Specification Tables


WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
END
This table can also be used to define the equivalency for English and metric diameters. The
output column defines the English equivalent for the matching metric size.

Neutral File Format - English/Metric Equivalency


Table_Data_Definition 'DWWW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 1
Units= NPD_MM, NPD_IN
! Metric Diam
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
END

Examples
Table_Data_Definition 'D036'
! Description= From 0.5 to 36
! By=NP
Ckd By=DG
Rev=0
No_Inputs 1 No_Outputs 0
Units= NPD_IN
! Diam
0.5
0.75
1
1.5
2
3
4
6
8
10
12
14
16
18
20
22
24
26

138

Date=22-Jan-1987

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


28
30
32
34
36
END
Table_Data_Definition 'DB001'
! Description= From 6mm to 900mm (0.375 to 36)
! By=aw
Ckd By=
Rev=1
Date=17_jul 1989
No_Inputs 1 No_Outputs 1
Units= NPD_MM, NPD_IN
! metric diam, imperial diam
10
0.375
15
0.5
20
0.75
25
1
40
1.5
50
2
80
3
100
4
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
550
22
600
24
650
26
700
28
750
30
800
32
850
34
900
36
END

Parameters

Table_Data_Definition (character 6) This field identifies the name of the NPD table.
These tables use the following naming conventions:
first character: D
second, third, and fourth characters: numbers from 001 through 999 used to make the
table name unique.
Diam - Nominal Piping Diameter (integer) This field identifies the value for nominal
diameter. You can use the value ET_AL to indicate that any nominal diameter value from the
TDB which is equal to or greater than the value in the preceding line is an acceptable nominal
diameter for the PMC.

Plant Design System (PDS) Reference Data Manager (PD_Data)

139

Piping Job Specification Tables

Thickness Data Tables


Thickness data is determined as a function of the table name and nominal piping diameter.
These tables include the minimum, retirement, thread, and preferred thicknesses required in the
calculation of piping wall thickness. The tables provide the actual thickness, not a schedule.
Therefore, there must be an individual entry for each diameter. You cannot use an NPD range.
PDS requires that the schedule/thickness values be in inches.

Neutral File Format


Table_Data_Definition 'TWWWW
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, SC_TH_IN, SC_TH_IN, SC_TH_IN, SC_TH_IN,
SC_TH_IN
! Diam
Min Thick Ret Thick Thread Thick Preferred
Schedules/Thicknesses
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
WWWWW ZZZZZ
ZZZZZ
ZZZZZ
ZZZZZ ZZZZZ ZZZZZ
ZZZZZ ZZZZZ
END

Example
Table_Data_Definition 'TA501'
! Description= A,0.063CA,0.0071D<=24, 0.0075D>=26
! By=DCG
Ckd By=DG
Rev=0
Date=31-Jan-1987
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, SC_TH_IN, SC_TH_IN, SC_TH_IN, SC_TH_IN,
SC_TH_IN
! Diam
Min Thick Ret Thick Thread Thick Preferred
Schedules/Thicknesses
0.5 .147
.06
S-160 0.75 .154
.06
S-XS
1
.179
.06
S-XS
1.5 .2
.06
S-XS
-

140

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


2
3
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
END

.154
.216
.237
.28
.250
.250
.250
.250
.250
.250
.250
.250
.250
.3125
.3125
.3125
.3125
.3125
.3125

.06
.06
.07
.1
.1
.1
.1
.12
.12
.12
.13
.15
.15
.17
.19
.20
.21
.23
.24

S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-STD
S-10
S-10
S-10
S-10
S-STD
S-STD

S-STD
S-STD
S-STD
S-STD
S-XS

Parameters

Table_Data_Definition - Thickness Data Table Name


(character 6) This field
identifies the name of the table. These tables use the following naming conventions:
first character: T
second character: code which combines the criteria type with the maximum size for
which threaded components are used in the piping materials class, as defined below.
Criteria 1 applies to carbon steels and low-alloy steels; criteria 2 applies to aluminum
alloys, stainless steels, and non-ferrous alloys.
A= Criteria 1 with no threaded components
B= Criteria 1 with threaded components up to 1 inch diameter
C= Criteria 1 with threaded components up to 1.5 inch diameter
D= Criteria 1 with threaded components up to 2 inch diameter
F= Criteria 2 with no threaded components
G= Criteria 2 with threaded components up to 1 inch diameter
H= Criteria 2 with threaded components up to 1.5 inch diameter
I= Criteria 2 with threaded components up to 2 inch diameter
Z= Special criteria
third character: the corrosion allowance of the piping materials class for which the table
is intended, per the following criteria:
1= None

C= 304 clad

P= Polyester lined

2= 0.020"

D= 304L clad

Q= Polypropylene lined

3= 0.030"

E= 316 clad

R= PTFE lined

4= 0.050"

F= 316L clad

S= Saran lined

5= 0.063"

G= 317 clad

T= Teflon lined

6= 0.10"

H= 317L clad

U= TK31 lined

Plant Design System (PDS) Reference Data Manager (PD_Data)

141

Piping Job Specification Tables


7= 0.125"

J=321 clad

V= R11 lined

8= 0.188"

L= Cement lined

W= R15 lined

9= 0.250"

M= Epoxy lined

X= R18 lined

A= 405 clad

N= Glass lined

Y= Other 1

B= 410S clad
O= Kynar lined
Z= Other 2
fourth and fifth characters: numbers from 01 through 99 used to make the table name
unique.
Diam - Nominal Piping Diameter (integer) This parameter identifies the desired value
for nominal diameter.
Min Thick - Minimum Required Thickness (real) This parameter represents the least
thickness, inclusive of corrosion allowance and mill tolerance, which is acceptable for a given
NPD. Either a positive number or a blank entry must be provided. This value is only used in
piping wall thickness calculations.
Ret Thick - Retirement Thickness (real) This parameter represents the least
thickness, exclusive of corrosion allowance, thread allowance, or mill tolerance, which is
acceptable for a given NPD.
Either a positive number or a blank entry must be provided.
This value is only used in piping wall thickness calculations.
Thread Thick - Thread Thickness (real) This parameter represents the thickness for
threaded pipe that must be added to the calculated wall thickness to account for the presence
of threads. Either a positive number or a blank entry must be provided. It is only used in
piping wall thickness calculations.
Preferred Schedule/Thicknesses 1 through 6 (real) These parameters represent the
schedules and/or thicknesses you prefer be used as a result of a piping wall thickness
calculation. Values in the table are arranged in ascending thickness sequence. The system
rounds the calculated wall thickness to the next higher preferred thickness. You are
restricted to a limit of six preferred thicknesses. PDS requires that these values be in inches.

Materials Data Table


The Materials Data Table consists of the materials data that is a function of the table name,
material grade, wall thickness range, and temperature. These tables include the properties
which are required for the calculation of piping wall thickness. You must insure that units of
measure used in the Materials Table are consistent with those used in the corresponding
Temperature-Pressure Table(s).
Note that you can express the mill tolerance as either a thickness percentage or a tolerance value.
Only one value can exist per table entry. If values exist for both, the system only uses the mill
thickness percentage.
The system uses the materials grade and temperature to access the information in the table and
provide the values of thickness range, coefficient Y, allowable stress (S), and the applicable mill
tolerance. Once the actual thickness is calculated for the component, the calculation software
compares that value with the thickness range. If the thickness range is exceeded, the next entry
in the materials table for the applicable materials grade and temperature is sought and the
calculation process is repeated.

Neutral File Format

142

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


Table_Data_Definition 'MWWW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 2 No_Outputs 6
Input_Interpolation 2, Next_One
Units= INT, DF, IN, IN, DEC, PSI, DEC, IN
!
Mill Tol
! Mat Gr Temp Thick Range
Y
S
%
Value
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
WWWW
ZZZZ ZZZZZ ZZZZZ ZZZ ZZZZZZ ZZZZZ ZZZZZ
END

Example
Table_Data_Definition 'ML01'
! Description= ASTM A53-B, A106, API 5L-B
! By=DCG
Ckd By=DG
Rev=0
Date=24-Feb-87
No_Inputs 2 No_Outputs 6
Input_Interpolation 2, Next_One
Units= INT, DF, IN, IN, DEC, PSI, DEC, IN
!
Mill Tolrnce
! Mat Gr Temp Thick Range
Y
S
%
Value
142
-20
.4
20000
12.5
142
100
.4
20000
12.5
142
200
.4
20000
12.5
142
300
.4
20000
12.5
142
400
.4
20000
12.5
142
500
.4
18900
12.5
142
600
.4
17300
12.5
142
650
.4
17000
12.5
142
700
.4
16500
12.5
142
750
.4
13000
12.5
142
800
.4
10800
12.5
162
-20
.4
20000
12.5
162
100
.4
20000
12.5
162
200
.4
20000
12.5
162
300
.4
20000
12.5
162
400
.4
20000
12.5
162
500
.4
18900
12.5
162
600
.4
17300
12.5
162
650
.4
17000
12.5
162
700
.4
16500
12.5
162
750
.4
13000
12.5
162
800
.4
10800
12.5
116
-20
.4
20000
12.5
116
100
.4
20000
12.5
-

Plant Design System (PDS) Reference Data Manager (PD_Data)

143

Piping Job Specification Tables


116
116
116
116
116
116
116
116
116
END

200
300
400
500
600
650
700
750
800

.4
.4
.4
.4
.4
.4
.4
.4
.4

20000
20000
20000
18900
17300
17000
16500
13000
10800

12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5

Parameters

Table_Data_Definition - Materials Data Table Name (character 6) This field identifies


the number of the table. These tables use the following naming conventions:
first character: M
second character: the applicable design code, per the following convention:
A= ASME Section I [Power Boilers]

L= ANSI-B31.3 [Petroleum]

B= ASME Section III [Nuclear]

M= ANSI-B31.4 [Oil Transport]

C= Do not use

N= ANSI-B31.5 [Refrigeration]

D= ASME Section VIII-1 [Unfired Vessels]

P= ANSI-B31.8 [Gas Transmission]

E= ASME Section VIII-2 [Unfired Vessels]

Q= ANSI-B31.9 [Building Services]

J= ANSI-B31.1 [Power]

T= API

K= ANSI-B31.2 [Fuel Gas]


V= AWWA
third and fourth characters: numbers from 01 through 99 used to make the table name
unique.
Input_Interpolation 2, Next_One This statement must be included as shown for
interpolation to take place. Interpolation is used for all the output fields, if required.
Mat Gr - Material Grade (integer - standard note 145) This code-listed parameter
identifies the materials grade. This compound attribute includes the code, specification,
grade, temper, and joint efficiency to be used for the component.
Temp - Temperature (real) This field identifies the applicable temperature for a set of
material properties.
Thick - Wall Thickness Range - low (real)
Range - Wall Thickness Range - high (real) These fields identify the lower and upper
wall thickness bounds for a set of material properties. You can enter positive numbers or
blanks. A blank indicates that the properties apply regardless of the thickness of the
component. You cannot define this range in terms of schedule.
Y - Coefficient Y (real) This parameter represents the coefficient Y corresponding to the
previously defined parameters in the line. You can enter a positive number or a blank.
S - Allowable Stress (real) This parameter represents the allowable stress
corresponding to the previously defined parameters in the line. You can enter a positive
number or a blank. S is the basic allowable stress for the material excluding casting, joint or
structural grade quality factor (E).
Mill Tol % - Mill Thickness Percentage (real) This parameter represents the per cent
of the wall thickness that is to be considered as mill tolerance for pipe material. Enter the mill
tolerance to be considered for the material as a percent of nominal thickness, such as 12.5%.

144

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

Mill Tol Value - Mill Thickness Value (real) This parameter represents the actual wall
thickness that is to be considered as mill tolerance for plate material. Enter the value of mill
tolerance to be considered for the material, such as 0.01 inch.

Branch Insertion Tables


A branch insertion table defines the selection criteria for tee and lateral branches. You must
specify the type of wye or cross to be placed in the model and specify the reinforcement data.
Branch tables define the reinforcement to be used at tee and lateral branches in the piping system
as a function of the acute angle of intersection and the nominal diameters for the intersecting lines.
These tables do not include the reinforcement required at Y's and crosses. For them, the
required reinforcement must be specified in Piping Design.
The types of tee branch connections include branch weld, coupling, thredolet, reducing tee, tee
with reducing insert, nipolet, branch weld with reinforcing pad, sockolet, tee, weldolet, tee with
reducing bushing, and reducing tee with reducer(s).
The system accesses the branch table when placing a component at an intersection when no
reinforcement component has been specifically defined.
The system uses the information in this table, and the header nominal diameter (first size) and
branch nominal diameter (second size) to provide the item name of the component to be used at
the intersection. Neither interpolation nor extrapolation is allowed.

Neutral File Format


Table_Data_Definition 'BWWWW_WW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 2 No_Outputs 4
Units= NPD_IN, NPD_IN, AN*6, AN*6, AN*6, IN
!
Nom Diam
Preferred Branch
! Header Branch
AABBCC Codes
Thickness
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
WWWWW
WWWWW
'ZZZZZZ' 'ZZZZZZ' 'ZZZZZZZ'
XXXX
END
If thickness is not defined, then the system checks for the number of components in the preferred
branch AABBCC codes component column. If there is only one component, then it is directly
placed. If there are two components, then the system performs branch reinforcement calculation.
If thickness is defined, the branch component is selected based on this thickness value against
the thickness of the connected header pipe. If the value of Thickness is greater than the header
thickness, the component from the first column under the preferred branch AABBCC codes is
used. If the value of the Thickness is less than the header thickness, component from the second
column under the preferred branch AABBCC codes is used.
The branch insertion table does not include two components (for example, tee and
reducer) at the same time. The software cannot place two components based on one set of
criteria. For example, if you are trying to place a 6"x6"x6" tee and a 6"x2" reducer, one must be
placed manually. There is no rule in the software allowing the placement of both components.

Plant Design System (PDS) Reference Data Manager (PD_Data)

145

Piping Job Specification Tables


Example
Table_Data_Definition 'BA901_90'
No_Inputs 2 No_Outputs 4
Units= NPD_IN, NPD_IN, AN*6, AN*6, AN*6, IN
!
Nom Diam
! Header Branch
24
24
24
24
24
24
24

10
12
14
16
18
20
24

Preferred Branch
AABBCC Codes
'6Q3C80'
'6Q3C80'
'6Q3C80'
'6Q3C80'
'6Q3C80'
'6Q3C86'
'6Q3C22'

'6Q3C73'
'6Q3C86'
'6Q3C86'
-

Thickness
-

.360
.380
-

END

Parameters

146

Table_Data_Definition - Branch Insertion Table Name (character 6) This field identifies


the name of the table. This name results from the compounding of the Branch Table entry
defined in the Piping Materials Class with the acute angle of intersection between the header
and the branch.
These tables use the following naming conventions:
first character: B
second character: a code which combines the criteria type with the maximum size for
which threaded components are used in the PMC, as defined below. Criteria 1 applies to
carbon steels and low-alloy steels; criteria 2 applies to aluminum alloys, stainless steels
and non-ferrous alloys.
A= Criteria 1 with no threaded components
B= Criteria 1 with threaded components up to 1 inch diameter
C= Criteria 1 with threaded components up to 1.5 inch diameter
D= Criteria 1 with threaded components up to 2 inch diameter
F= Criteria 2 with no threaded components
G= Criteria 2 with threaded components up to 1 inch diameter
H= Criteria 2 with threaded components up to 1.5 inch diameter
I= Criteria 2 with threaded components up to 2 inch diameter
Z= Special criteria
third character: the corrosion allowance of the piping materials class for which the table
is intended, per the following criteria:
1= None

C= 304 clad

P= Polyester lined

2= 0.020"

D= 304L clad

Q= Polypropylene lined

3= 0.030"

E= 316 clad

R= PTFE lined

4= 0.050"

F= 316L clad

S= Saran lined

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

5= 0.063"

G= 317 clad

T= Teflon lined

6= 0.10"

H= 317L clad

U= TK31 lined

7= 0.125"

J=321 clad

V= R11 lined

8= 0.188"

L= Cement lined

W= R15 lined

9= 0.250"

M= Epoxy lined

X= R18 lined

A= 405 clad

N= Glass lined

Y= Other 1

B= 410S clad
O= Kynar lined
Z= Other 2
fourth and fifth characters: numbers from 01 through 99 used to make the table name
unique.
The second part of the table name defines the acute angle of intersection. Negative
values and values less than 45 degrees or greater than 90 degrees are not valid.
However, when dealing with branch reinforcements, negative values and values less than
20 degrees or greater than 90 degrees are not valid (per ANSI B31.1 and ANSI B31.3).
The data fields are sorted by header NPD and then by branch NPD.
Nom Diam Header - NPD for Run (integer) --- This field identifies the nominal diameter of
the header at the intersection. This is the member with the largest nominal diameter.
Nom Diam Branch - NPD for Branch (integer) --- This field identifies the nominal
diameter of the branch member at the intersection. This is the member with the smallest
nominal diameter.
Preferred Branch AABBCC Codes
(character 6) --- These field identify the commodity
item name of the component used to reinforce the intersection.
If only one item name is listed, no branch reinforcement calculation is performed. The
specified item is placed at the intersection.
If two or more item names apply in one line, the system calculates the branch
reinforcement thickness. The system tests the listed item names sequentially (from left
to right) until the applicable strength criteria are satisfied.
Therefore, these codes should be arranged in ascending strength sequence (for example,
reinforcing welds, followed by reinforcing pads, followed by weldolets.)
If you enter a value of LOOKUP in the AABBCC field, it will refer to the BRANCHID.LN file
in the \project directory. You must create this file and edit the attributes. For an example of
the file format, see BRANCHID.LN File (on page 148)
Typically, the codes are from one of the following types:
Reinforcing elements, such as reinforcing welds and pads.
Weld-on components reinforcing the intersection such as saddles and weldolets.
Weld-in components actually making the intersection such as laterals and tees.

Plant Design System (PDS) Reference Data Manager (PD_Data)

147

Piping Job Specification Tables

BRANCHID.LN File
The BRANCHID.LN file must be placed in the \project directory and is formatted as shown below:
MATCHING_ATTRIBUTES: 3
LINE_DEF: WC-0104
BRANCH_DEF: 5192; 5192; 6Q3C22
BRANCH_DEF: 5768; 5320; 6Q3C80
LINE_DEF: WC-0105
BRANCH_DEF: 5192; 5032; ATECH

MATCHING_ATTRIBUTES - Defines the search criteria for the pipeline to be revised. The
value 3 is the attribute number as defined by the Design DDL and Piping Segment Data, and 3
is therefore equal to line_id.
LINE_DEF - Used with the MATCHING_ATTRIBUTES value. In the example above, the first
MATCHING_ATTRIBUTES: 3 value is WC-0104. The software searches for pipeline
WC-0104 to place the branching component.
BRANCH_DEF - Determines which branch value is placed on the pipeline based on the first
and second size attributes. If the first and second size attributes match, the branch value is
used. For example, in the second BRANCH_DEF line of the WC-0104 LINE_DEF section, the
first and second size attributes are 5768 and 5320, respectively. If these attributes match up,
then the value 6Q3C80 is placed on the WC-0104 pipeline.
BRANCH_DEF - Determines which branch value is placed on the pipeline based on the first
and second size attributes. If the first and second size attributes match, the branch value is
used. For example, in the second BRANCH_DEF line of the WC-0105 LINE_DEF section, the
first and second size attributes are 5192 and 5032, respectively. If these attributes match up,
then the value ATECH is placed on the WC-0105 pipeline.

The piping assembly TECH must be proceeded by an A.


The BRANCHID.LN file references the Piping Assembly Library when a value of "LOOKUP" is
placed in the AABBCC field of the branch insertion table. Below is an example of the lookup
value in the branch insertion table:
!
Nom Diam
Preferred Branch
! Header Branch
AABBCC Codes
0.75
0.75
'6Q3C22' 1
0.75
'6Q3C24' 1
1
'6Q3C22' 1.5
0.75
'6Q3C24' 1.5
1
'6Q3C24' 1.5
1.5
'6Q3C22' 2
0.75
'6Q3C74' 2
1
'6Q3C74' 2
1.5
'6Q3C74' 2
2
'6Q3C22' 3
0.75
'6Q3C74' 3
1
'6Q3C74' 3
1.5
'6Q3C74' > 3
2
'LOOKUP' 3
3
'6Q3C22' 4
0.75
'6Q3C74' -

148

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

>
>

>
>
>

4
4
4
4
4
6
6
6
6
6
6
6

1
1.5
2
3
4
0.75
1
1.5
2
3
4
6

'6Q3C74'
'6Q3C74'
'6Q3C73'
'LOOKUP'
'6Q3C22'
'6Q3C74'
'6Q3C74'
'6Q3C74'
'6Q3C73'
'6Q3C73'
'LOOKUP'
'6Q3C22'

END

Gasket Separation Table


These tables define the gasket gap to be used for a given nominal diameter and maximum
temperature.
For each bolted end, the system uses the applicable table, the NPD of the end, and the maximum
temperature for the gasket to be used at the end, to determine the gap thickness to be used at the
end. Lines in this table are sorted by NPD first and maximum temperature second.

Neutral File Format


Table_Data_Definition 'GWWW_WWWWWW'
! Description= ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 2 No_Outputs 1
Units= NPD_IN, DF, IN
! Diam
TMx Gaskt Gap
WWWWW ZZZ ZZZZZ WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
WWWWW ZZZ ZZZZZ
END

Example
Table_Data_Definition 'G001_1500'
! Description= SP-1000 deg F , RJ-1001 deg F
! By=DCG
Ckd By=DCG
Rev=0
Date=24-Jun-1987
No_Inputs 2 No_Outputs 1
Units= NPD_IN, DF, IN
! Diam
TMx Gaskt Gap
0.5
1000 .125
0.75
1000 .125
1
1000 .125
1.5
1000 .125

Plant Design System (PDS) Reference Data Manager (PD_Data)

149

Piping Job Specification Tables


2
3
4
6
8
10
12
14
16
18
20
24
0.5
0.75
1
1.5
2
3
4
6
8
10
12
14
16
18
20
24
END

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001
1001

.125
.125
.125
.125
.125
.125
.125
.125
.125
.125
.125
.125
.16
.16
.16
.16
.12
.12
.12
.12
.16
.16
.19
.22
.31
.31
.38
.44

Parameters

150

Table_Data_Definition - Gasket Gap Table Name (character 6) This field identifies


the name of the table. This name results from the compounding of the entry defined in the
Piping Materials Class with the rating of the bolted end to which the gasket gap applies.
These tables use the following naming conventions:
first character: G
next three characters: numbers from 001 through 999 used to make the table name
unique.
The second part of the table name is the rating of the components to which it applies.
The characters CL and # are not included in the rating designation.
Diam - Nominal Piping Diameter This field identifies the applicable NPD value. The units
of measure used to define the NPD must match the NPD units to be used in the Piping model.
TMx - Maximum Temperature This field identifies the maximum temperature for the
gasket as defined in the Piping Commodity Specification Data (Table 202 attribute 5). (The
system must find a match of the commodity item temperature and the value in this column for
successful retrieval of data.)
The units of measure used to define the temperature must be the same as the units used in
the Temperature Pressure Service Limits table.
Gasket Gap This field identifies the full gasket gap to be used.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

Fluid Code Table


Fluid Code tables can be used to limit the number of fluid codes which are valid for a particular
Piping Material Class. A Fluid Code table works much like the Diameters table. Where the
Diameters Table contains a valid set of diameters for a PMC, the Fluid Code table contains a set
of valid Fluid Codes for a PMC.
To use a Fluid Code table,
Specify the name of the Fluid Code Table in the fluid_code attribute of the Piping Materials
Class definition.
Set the Fluid Code Control toggle to Yes on the Piping Data Control form of the Project Data
Manager. Refer to the Project Administrator (PD_Project) Reference Guide for more
information on this form.

Neutral File Format


Table_Data_Definition 'FC001'
! Description= By Process Vendor
! By=SCC
Ckd By=SCC
Rev=1
No_Inputs 1 No_Outputs 0
Units= INT
521
522
524
527
530
533
536
539
542
545
550
END

Date=12-OCT-90

Parameters

Table_Data_Definition (character 6) This field identifies the name of the Fluid Code
table. These tables use the following naming conventions:
first and second character: FC
third, forth, and fifth characters: numbers from 001 to 999 used to make the table name
unique.
Fld Cd (integer) This field lists the code list numbers for the valid fluid codes from code
list set 125.

Plant Design System (PDS) Reference Data Manager (PD_Data)

151

Piping Job Specification Tables

Wall Thickness and Branch Reinforcement Equations


These equations define formulas for the calculation of piping wall thickness and branch
reinforcement to resist positive pressure. The actual equations and their logic are hard-coded in
the software. PDS requires that the thickness value be defined in inches.
Thickness equations have project unique names which must follow the following convention:
first character: E
second character: the applicable design code, per the following convention:
A= ASME Section I

[Power Boilers]

B= ASME Section III

[Nuclear]

C= Do not use
D= ASME Section VIII-1

[Unfired Vessels]

E= ASME Section VIII-2

[Unfired Vessels]

J= ANSI-B31.1

[Power]

K= ANSI-B31.2

[Fuel Gas]

L= ANSI-B31.3

[Petroleum]

M= ANSI-B31.4

[Oil Transport]

N= ANSI-B31.5

[Refrigeration]

P= ANSI-B31.8

[Gas Transmission]

Q= ANSI-B31.9

[Building Services]

T= API
V= AWWA
third and fourth characters: numbers from 01 through 99 used to make the equation
name unique.
If the equation name is provided as part of the definition *Cyyy in the Schedule/Thickness
attribute of the Piping Commodity Specification Data table, the equation name must be limited
to the format Ex; no third or fourth character can be defined.
These equations define formulas for the calculation of piping wall thickness and branch
reinforcement to resist positive pressure.

Delivered Equations
The thickness and branch reinforcement logic for the following equations are hardcoded in the
software.
EJ01
Source - ANSI-B31.1.1986 [Power Piping]
Thickness logic from paragraph 104.1, equation 3
Reinforcement logic from paragraph 104.3.1(D)

152

EL01

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


Source - ANSI-B31.3c.1986 [Chemical Plant and Petroleum Refinery Piping]
Thickness logic from paragraph 304.1, equation 3a
Reinforcement logic from paragraph 304.3.3 & Code - Appendix H

The following considerations apply to both thickness equations and branch reinforcement
calculations.
Pressures and temperatures used in thickness/branch reinforcement calculations are derived
from data in the Piping Design Database. Both normal and alternate pressure and
temperature conditions are considered. If actual values exist for the normal design or the
alternate design pressure/temperatures, the corresponding operating conditions are ignored.
If default values exist for BOTH sets of design conditions, both normal and alternate operating
conditions are used. At least one complete set of conditions must be defined.
Once the proper pressure and temperature sets are determined, their units of measure are
converted to those used in the Temperature-Pressure Table associated with the Piping
Materials Class to which the component belongs. Conversions are performed using the
procedures and conversion factors defined for the Units of Measure in Appendix F.
Only positive pressure is considered. The system reports an error if you request a thickness
calculation involving a vacuum condition (negative pressure).
Independent sets of thickness/reinforcement calculations are carried out for each applicable
pressure/temperature set. In each calculation set, table values that are temperature
dependent are determined on the basis of the temperature applicable to the calculation set
being considered. The thicker calculated thickness is used.

Thickness Equations
The following considerations apply to thickness equations.
Thickness calculations are triggered by specifying an equation name in the
Schedule/Thickness attribute of the Piping Commodity Specification Data. An asterisk (*)
followed by a name (of the form xyyy) defines the specific calculation or table lookup to be
used for wall thickness. The letters that form this code have the following meaning:
x alphanumeric code that defines the equation to use in the calculation. Possible values
and their definitions are:
If this character is C, the schedule/thickness for the applicable end of the component is
determined by calculations using the thickness equation defined in the
DEFAULT_WALL_THICK_EQUATION attribute of the Piping Materials Class database
table.

Plant Design System (PDS) Reference Data Manager (PD_Data)

153

Piping Job Specification Tables

If the code is any character other than C, the schedule/thickness for the applicable end of
the component is determined by calculations using the thickness equation with the name
EX.
yyy casting, joint or structural grade quality factor (E) times 100.
This factor is one of the parameters used in the thickness calculation. If you are defining a
calculation to be performed on a seamless fitting (E=1) but want to match the thickness for the
mating welded pipe (E=0.85), the quality factor for the pipe should be entered here.
For components with ends having different nominal diameters, independent sets of thickness
determinations are performed for each NPD. One or more ends may need to calculated, as
determined by specific *xyyy entries in the Commodity Item entity. The larger thickness
(calculated or predefined) is used. For example:
A 20" x 10" reducer is defined in the Piping Commodity Table to have a *xyyy 20" end and
a 0.55" thick, 10" end. The calculation of the 20" end results in a 0.5" thickness. A 0.55"
thick reducer is used.
A 24" x 20" reducer is defined in the Piping Commodity Table to have a *XYYY 24" end
and a *XYYY 20" end. The calculation of the 24" end results in a 0.6" thickness. The
calculation of the 20" end results in a 0.5" thickness. A 0.6" thick reducer is used.
All thickness calculations involve a casting, joint, or structural grade quality factor (E).
The value for this factor is YYY/100, where YYY is defined in the entry *XYYY made under
the Schedule Thickness attribute for the Commodity Item under consideration.

Branch Reinforcement
The following considerations apply to branch reinforcement calculations.
The need to perform a branch reinforcement calculation is triggered by
the placement of a generic branch component with the actual item name determined from
a branch table. (See Branch Insertion Tables.)
the presence of more than one item name in the Preferred Branch AABBCC Codes fields
of the applicable branch table.
the applicable branch reinforcement being either a reinforcing weld or a reinforcing pad.
All calculations involve a casting, joint, or structural grade quality factor (E). The value for this
factor is YYY/100, where YYY is defined in the Modifier attribute for entries with an item name
of PIPING.
The fillet welds joining reinforcing pads to the header and to the branch are considered in
determining the available reinforcement area.

Spec Access
The execution of a pipe wall thickness calculation is performed when the variable PIPE_OD_n is
encountered in the physical data definition of a pipe or component. Therefore, pipe outside
diameter must be calculated or retrieved from a table before the wall thickness can be used as
part of a table name.
After the actual thickness is calculated, it is compared against the thickness range in the Materials
table and the retirement thickness in the Thickness Data table. The system uses the greater of
these values as the uncorroded wall thickness. Then the system adds the corrosion allowance
from the PMC, the thread thickness from the wall thickness table, and the mill tolerance from the
Materials table. This revised thickness is compared against the minimum thickness value in the
Thickness Data table. The larger of these two values is compared against the preferred
thickness value in the Thickness Data table, and the next largest preferred value is used for table
look-ups and is stored in the TDB.

154

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


If the Thickness Data table uses schedules as preferred thickness, the schedules are translated to
an actual thickness by a table look-up from a table of the form
MALWT//Term_type//shc_thick//generic_flag//weight_code
and output 2 gives the actual wall thickness.

Verification of Schedule Thickness


You can set an option in the RDB to determine how the piping segment override
schedule/thickness value will be handled during wall thickness calculations. By default, the piping
segment schedule/thickness override is used in place of the value determined from the Piping Job
Specification.

RDB Tables
The following reference data tables are defined in the Spec Table Library. These tables are
required to provide basic data for the performance of the software.
TNF

Table Name

G02

COMMODITY_ITEM_NAME (see "Commodity Item Name


Table (G02)" on page 156)

G04

BEND_DEFLECTION (see "Bend Deflection Table (G04)"


on page 158)

G06

PIPE_RUN_LENGTH (see "Segment Pipe Run Length


Threshold Table (G06)" on page 159)

G07

PIPE_LENGTH (see "Pipe Length Threshold Table (G07)"


on page 160)

G11

BOLT_LENGTH (see "Preferred Bolt Length Table (G11)"


on page 161)
WELD_TYPE_TABLE (see "Weld Type Table" on page
164)
WELD_C10031 (see "Weld Clearance Table" on page
167)
DRV_WELD_DEF (see "Weld Graphics Dimensions
Table" on page 168)
CommodityCode_BLT (Bolt Commodity Code Table (on
page 166))
CommodityCode_GKT (Gasket Diameter Table (on page
169))
FIELD_FIT_LENGTH (see "Field Fit Length Table" on
page 170)
Component_Mirror_Table (see "Component Mirror Table"
on page 170)
Operator_Mirror_Table (see "Operator Mirror Table" on
page 171)
Default_End_Prep (see "Default End Preparation Table"

Plant Design System (PDS) Reference Data Manager (PD_Data)

155

Piping Job Specification Tables


on page 172)
MTO Tables and Functions (on page 172)
The system uses the settings in the Component Placement and Material TakeOff forms of the
Project Data Manager to determine the applicable names for these basic tables.
Refer to Table Formats and Naming Conventions (on page 219) for information on the
basic conventions used for PDS tables.

Commodity Item Name Table (G02)


The commodity item name table is used when placing a component at the vertex of an existing
piping segment (in either automatic or manual component placement). It enables you to relate
the component types (1 to 70) hard-coded in the software with the applicable Item Names. As
the system processes the segment for component placement, it uses the derived Item Name from
this table to reference the Piping Commodity Specification data in the Specification Material
Reference Database.
When placing change of direction components, this table is used in conjunction with the Bend
Deflection Table.
The table name format that applies to this table is:
TNF=G02 COMMODITY_ITEM_NAME

Example
Table_Data_Definition 'COMMODITY_ITEM_NAME'
! Description= Correlation of hardcoded component types and AABBCC codes
! By=GJH
Ckd By=DCG
Rev=2
Date=16-May-1989
No_Inputs 1 No_Outputs 1
Units= INT, AN*6
! Comp
AABBCC
! Type
Code
1
'PIPING'
2
'TUBING'
3
'HOSE'
4
'6Q2C23'
5
'6Q2C01'
6
'6Q2C01'
7
'6Q2C76'
8
'6Q2C75'
9
'6Q2C56'
10
'6Q2C55'
11
'6Q3C45'
12
'6Q3C60'
13
'6Q2C47'
14
'6Q2C84'
15
'6Q3C47'
16
'6Q3C49'
17
'6Q3C50'
18
'6Q3C25'
19
'6Q3C47'
20
'6Q3C77'
21
'6Q3C82'
22
'6Q3C80'

156

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


> 23
> 24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
END

'6Q3C88'
'6Q2C24'
'6Q1C76'
'6Q2C16'
'6Q2C19'
'6Q2C21'
'6Q2C08'
'IND'
'6Q2C49'
'6Q2C51'
'6Q2C53'
'6Q2C06'
'6Q3C89'

The meaning of the various component types is outlined below:


Comp Type

Definition

Piping (not used by the software)

Tubing (not used by the software)

Hose (not used by the software)

Concentric diameter change

Flange in bends

Flange in other components

90 degree directional change

45-90 degree directional change

45 degree directional change

10

< 45 degree directional change

11

True Y

12

Equal size cross (if not equal size, software will handle as a branch)

13

> 90 pipe bend

14

90 degree reducing elbow

15

Lateral (not used by the software)

16

Reducing lateral

17

Reducing run and branch lateral

Plant Design System (PDS) Reference Data Manager (PD_Data)

157

Piping Job Specification Tables


Comp Type

Definition

18

Reducing run and branch tee

19

Lateral (not used by the software)

20

Elbolet (used by Compute for Elbolet under the Tap command)

21

Reinforcing weld

22

Reinforcing pad

23

Branch nipple

25-27

vent/drain valve A - C

28

end

29

plug

30

cap

31

blind flange

32-37

Closing component A - F

38-40

Instrument indicator A - C

41

5.625 degree bend

42

11.25 degree bend

43

22.5 degree bend

44

Orifice flange

45

In-line nipple

51-60

Pipe-like commodity item 1 - 10

61-70
Pipe-like model code 1 - 10
If you do not want to place one of the above component types as part of automatic component
placement, place a hyphen (-) for the Item Name.

Bend Deflection Table (G04)


The bend deflection table is used when placing a component at the vertex of an existing piping
segment (in either automatic or manual component placement). The system uses the bend
angle at the segment vertex to determine the type of component to be placed.
This table contains the following data:
bend angle - low
bend angle - high
index into the Commodity Item Name table for a full size bend
index into the Commodity Item Name table for a reducing bend
This table defines which full size and reducing size component types will be placed for a specified
angle range. The angle is defined as the smallest angle that the continuation of one pipe run
makes with the other run. The component types are defined in the commodity item name table.
See Commodity Item Name Table (G02) (on page 156). A value of 0 for the type indicates that
no reducing component should be placed for an angle range.

158

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


The system uses the bend angle to search this table for the matching range of bend angles. The
system uses the index into the Commodity Item Name table for either a full size bend or a reducing
bend depending upon the nominal piping diameters of the line route segments that form the bend.
The system searches for an entry in the table where the angle is greater than or equal to the low
bend angle and less than the high bend angle.
You can define more than one bend deflection table for a project provided they are given different
names. For example, one table can apply to underground piping and the other to aboveground
piping. Refer to the Component Placement form in the Project Data Manager for information
on defining the bend deflection table for a project or model.
The table name format that applies to this table is:
TNF=G04 BEND_DEFLECTION

Example
Table_Data_Definition 'BEND_DEFLECTION'
! Description= Component type to use as function of angle between runs
! By=EPZ
Ckd By=DCG
Rev=2
Date=09-Nov-1987
No_Inputs 2 No_Outputs 2
Units= DEC, DEC, INT, INT
!
Angle
Comp Type To Use
! Low
High
Full
Red
0.1
44.9
10
0
44.9
45.1
9
0
45.1
89.9
8
0
89.9
90.1
7
14
90.1
179.9 13
0
END
The following listing shows the component types used in this example.
bend angle
index
low
high
full size
reducing size
0.1
44.9
10 ( < 45 trimmed bend)
N/A
44.9
45.1
9 (45 bend)
N/A
45.1
89.9
8 (45-90 trimmed bend)
N/A
89.9
90.1
7 (90 bend)
14 (reducing 90 bend)
90.1
179.9
13 ( > 90 trimmed bend)
N/A

Segment Pipe Run Length Threshold Table (G06)


This table enables you to define the minimum allowable segment run length which can be placed
in the model during centerline routing. The values defined in this table do not apply to the segment
run automatically created by the software when placing components end to end.
The Piping Designer insures that the length of any pipe run of a piping segment exceeds the
active segment run length threshold. The threshold is determined from this table as a function of
nominal piping diameter. The only exception to this is for the small pipe run required for the offset
of an eccentric reducer. This threshold is used to insure that the pipe run between two connected
bends exceeds the fabrication length of the two bends.
The value for nominal diameter is interpreted as follows:
Diam Entry

Range of Diameters Covered

n1

nominal diameter < n1

Plant Design System (PDS) Reference Data Manager (PD_Data)

159

Piping Job Specification Tables


n2

n1 <= nominal diameter < n2

n3

n2 <= nominal diameter < n3

...
n8
n9
n8 <= nominal diameter
Using this scheme, you should look on the line following the actual segment NPD to determine the
minimum length. Only lengths greater than the minimum length in the table are allowed. For
example, if you are placing a segment with 12 inch NPD, you can only place segments greater
than .75 inches in length.
The table name format that applies to this table is:
TNF=G06 PIPE_RUN_LENGTH

Example
Table_Data_Definition 'PIPE_RUN_LENGTH'
! Description= Minimum allowable piping segment run length
! By=DCG
Ckd By=GJH
Rev=1
Date=04-Aug-1987
No_Inputs 1 No_Outputs 1
Units= NPD_IN, IN
! Diam
Min Length
2
0.25
6
0.50
12
0.50
24
0.75
36
1.00
96
1.00
144
1.00
192
1.00
END

Pipe Length Threshold Table (G07)


This table enables you to define the minimum and preferred allowable pipe lengths which can be
placed (manually or by automatic component placement).
The Piping Designer insures that the length of any pipe or tube exceeds the pipe length
threshold, as defined in this table. The threshold is determined as a function of the nominal
piping diameter. This table is used during model creation and model revision activities to verify
the nominal or theoretical pipe (or tube) length.
Any value for nominal diameter is interpreted as follows:
Diam Entry

Range of Diameters Covered

n1

nominal diameter <= n1

n2

n1 < nominal diameter <= n2

n3

n2 < nominal diameter <= n3

...

160

n8

n7 < nominal diameter <= n8

n9

n8 < nominal diameter <= n9

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


Using this scheme, you should look on the line following the actual NPD to determine the minimum
length, unless the NPD is equal to one of the diameter entries. Only lengths greater than the
minimum length in the table are allowed. For example, if you are placing a pipe with 14 inch
NPD, you can only place pipe runs greater than 3 inches in length.
The table name format that applies to this table is:
For TNF=G07 PIPE_LENGTH

Example
Table_Data_Definition 'PIPE_LENGTH'
! Description= Minimum and preferred allowable plain piping length
! By=DCG
Ckd By=GJH
Rev=1
Date=04-Aug-1987
No_Inputs 1 No_Outputs 2
Units= NPD_IN, IN, IN
!
Min
Preferred
! Diam
Length
Length
2
2
2
6
2
3
12
2
4
24
3
6
36
3
9
96
3
12
144
6
12
192
6
12

Preferred Bolt Length Table (G11)


The data for bolts and gaskets is a function of nominal diameter, end preparation for each mating
flange, and pressure rating for each mating flange. The bolt length table supplies data for machine
bolts, stud bolts, and cap screws. It determines the bolt data required for both regular and
bolt-thru bolts. This table enables you to define the low and high range for calculated bolt lengths
and the corresponding preferred or purchased lengths of the bolt.
You can define up to 300 entries in this table.
The table name format that applies to this table is:
For TNF=G11 BOLT_LENGTH
Refer to the Report Manager Reference Guide for more information on bolt tables and bolt table
logic.

Example
Table_Data_Definition 'BOLT_LENGTH'
! Description= Preferred bolt lengths (maximum of 300 entries)
! By=GJH
Ckd By=DCG
Rev=1
Date=04-Aug-1987
No_Inputs 2 No_Outputs 1
Units= IN, IN, IN
!
Bolt Length
Preferred
! Low
High
Bolt Length
0.0
1.5
1.5
1.5001
1.75
1.75
1.7501
2
2
2.0001
2.25
2.25
2.2501
2.5
2.5

Plant Design System (PDS) Reference Data Manager (PD_Data)

161

Piping Job Specification Tables


2.5001
2.7501
3.0001
3.2501
3.5001
3.7501
4.0001
4.2501
4.5001
4.7501
5.0001
5.2501
5.5001
5.7501
6.0001
6.2501
6.5001
6.7501
7.0001
7.2501
7.5001
7.7501
8.0001
8.2501
8.5001
8.7501
9.0001
9.2501
9.5001
9.7501
10.0001
10.2501
10.5001
10.7501
11.0001
11.2501
11.5001
11.7501
12.0001
12.2501
12.5001
12.7501
13.0001
13.2501
13.5001
13.7501
14.0001
14.2501
14.5001
14.7501
15.0001
15.2501
15.5001
15.7501

162

2.75
3
3.25
3.5
3.75
4
4.25
4.5
4.75
5
5.25
5.5
5.75
6
6.25
6.5
6.75
7
7.25
7.5
7.75
8
8.25
8.5
8.75
9
9.25
9.5
9.75
10
10.25
10.5
10.75
11
11.25
11.5
11.75
12
12.25
12.5
12.75
13
13.25
13.5
13.75
14
14.25
14.5
14.75
15
15.25
15.5
15.75
16

2.75
3
3.25
3.5
3.75
4
4.25
4.5
4.75
5
5.25
5.5
5.75
6
6.25
6.5
6.75
7
7.25
7.5
7.75
8
8.25
8.5
8.75
9
9.25
9.5
9.75
10
10.25
10.5
10.75
11
11.25
11.5
11.75
12
12.25
12.5
12.75
13
13.25
13.5
13.75
14
14.25
14.5
14.75
15
15.25
15.5
15.75
16

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


16.0001
16.2501
16.5001
16.7501
17.0001
17.2501
17.5001
17.7501
18.0001
18.2501
18.5001
18.7501
19.0001
19.2501
19.5001
19.7501
20.0001
20.2501
20.5001
20.7501
21.0001
21.2501
21.5001
21.7501
22.0001
22.2501
22.5001
22.7501
23.0001
23.2501
23.5001
23.7501
24.0001
24.2501
24.5001
24.7501
25.0001
25.2501
25.5001
25.7501
26.0001
26.2501
26.5001
26.7501
27.0001
27.2501
27.5001
27.7501
28.0001
28.2501
28.5001
28.7501
29.0001
29.2501

16.25
16.5
16.75
17
17.25
17.5
17.75
18
18.25
18.5
18.75
19
19.25
19.5
19.75
20
20.25
20.5
20.75
21
21.25
21.5
21.75
22
22.25
22.5
22.75
23
23.25
23.5
23.75
24
24.25
24.5
24.75
25
25.25
25.5
25.75
26
26.25
26.5
26.75
27
27.25
27.5
27.75
28
28.25
28.5
28.75
29
29.25
29.5

16.25
16.5
16.75
17
17.25
17.5
17.75
18
18.25
18.5
18.75
19
19.25
19.5
19.75
20
20.25
20.5
20.75
21
21.25
21.5
21.75
22
22.25
22.5
22.75
23
23.25
23.5
23.75
24
24.25
24.5
24.75
25
25.25
25.5
25.75
26
26.25
26.5
26.75
27
27.25
27.5
27.75
28
28.25
28.5
28.75
29
29.25
29.5

Plant Design System (PDS) Reference Data Manager (PD_Data)

163

Piping Job Specification Tables


29.5001
29.7501
30.0001
30.2501
30.5001
30.7501
31.0001
31.2501
31.5001
31.7501
32.0001
32.2501
32.5001
32.7501
33.0001
33.2501
33.5001
33.7501
34.0001
34.2501
34.5001
34.7501
35.0001
35.2501
35.5001
35.7501
END

29.75
30
30.25
30.5
30.75
31
31.25
31.5
31.75
32
32.25
32.5
32.75
33
33.25
33.5
33.75
34
34.25
34.5
34.75
35
35.25
35.5
35.75
36

29.75
30
30.25
30.5
30.75
31
31.25
31.5
31.75
32
32.25
32.5
32.75
33
33.25
33.5
33.75
34
34.25
34.5
34.75
35
35.25
35.5
35.75
36

Weld Type Table


This table defines the weld type code for a given pair of fabrication category values. The
fabrication category values are determined from the connect point data at each of the mating
welded ends.
The table name format that applies to this table is:
WELD_TYPE_TABLE

Example
Table_Data_Definition 'Weld_Type_Table'
No_Inputs 2 No_Outputs 1
Units = INT, INT, INT
! Fab Cat 'A'
1
1
1
1
1
1
1

164

Fab Cat 'B'

Weld Type

1
5
7
15
16
17
25

1
21
21
21
21
21
21

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


1
1
1
1
1
1
1
5
5
5
5
5
5
5
5
5
5
5
5
5
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
16
16
16
16
16
16
16
16
16
16
17

27
35
37
45
47
95
97
5
7
15
16
17
25
27
35
37
45
47
95
97
7
15
16
17
25
27
35
37
45
47
95
97
15
16
17
25
27
35
37
45
47
95
97
16
17
25
27
35
37
45
47
95
97
17

21
21
21
21
21
21
21
11
21
11
21
21
11
21
11
21
11
21
11
21
21
21
21
21
21
21
21
21
21
21
21
21
11
21
21
11
21
11
21
11
21
11
21
12
21
21
21
21
21
21
21
21
21
21

Plant Design System (PDS) Reference Data Manager (PD_Data)

165

Piping Job Specification Tables


17
17
17
17
17
17
17
17
25
25
25
25
25
25
25
25
27
27
27
27
27
27
27
35
35
35
35
35
35
37
37
37
37
37
45
45
45
45
47
47
47
95
95
97

25
27
35
37
45
47
95
97
25
27
35
37
45
47
95
97
27
35
37
45
47
95
97
35
37
45
47
95
97
37
45
47
95
97
45
47
95
97
47
95
97
95
97
97

21
21
21
21
21
21
21
21
11
21
11
21
11
21
11
21
21
21
21
21
21
21
21
11
21
11
21
11
21
21
21
21
21
21
11
21
11
21
21
21
21
11
21
21

Bolt Commodity Code Table


This table is used if the Basis of Bolt Commodity Code is set to Bolt Commodity Code Table in the
Project Data Manager. The system uses the bolt length and bolt diameter to find the commodity
code in the table.
If you define a bolt commodity code which is less than 17 characters, you should code a hyphen (-)
in the third column.
The table name format that applies to this table is:

166

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


Cmdty Code_BLT

Neutral File Format


Table_Data_Definition 'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW_BLT'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
No_Inputs 2 No_Outputs 4
Units= IN, IN, IN, AN*8, AN*8, AN*8
! Bolt
Bolt Length
Bolt Commodity Code
! Diam
Low
High
1
2
3
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
WWWWW WWWWWWW WWWWWWW ZZZZZZZZ ZZZZZZZZ ZZZZZZZZ
END
Do not load the Bolt Commodity Code table with more than 900 lines.
If Bolt Commodity Code is set to Bolt Commodity Code Table, the Commodity Code and
Bolt Description is reported from this table.
Commodity Code Bolt Commodity Code
Toggle
Toggle

PD Report

PD MDP

size_independent

Piping Job Spec

System Commodity Code System Commodity


(table_202)
Code (table_202)

size_independent

Bolt Commodity Code


table

Commodity Code from


Bolt Commodity Code
Table

Commodity Code
from Bolt Commodity
Code Table

size_dependent

Piping Job Spec

Size Dependent
Commodity Code
(table_211)

Size Dependent
Commodity Code
(table_211)

size_dependent

Bolt Commodity Code


Table

Commodity Code from


Bolt Commodity Code
Table

Commodity Code
from Bolt Commodity
Code Table

Weld Clearance Table


This table contains information obtained from the NPD and the Weld Type table, which are
retrieved from the piping model. Add a version of this table to the Physical Data Library for each
spec.
The table name format that applies to this table is:
WELD_SpecName

Plant Design System (PDS) Reference Data Manager (PD_Data)

167

Piping Job Specification Tables


Example
Table_Data_Definition 'WELD_1C0031'
! Description= Weld Clearance Table
By=XXX
Ckd By=XXX Rev=1
Date=01-22-1999
No_Inputs 2 No_Outputs 4
Units= NPD_IN, INT, NPD_IN, INT, IN, IN
Weld
Weld
NPD
Type
NPD
Type
Radius
Overall
From From
To
To
Increase
Length
1
1
2
25
6
18
3
1
4
25
8
24
5
1
6
25
10
30
7
1
8
25
6
18
9
1
10
20
10
18
9
21
10
22
12
24
9
23
10
25
14
30
11
1
12
25
10
30
END

Parameters

NPD From - NPD To (integer) These parameters identify the range of nominal piping
diameters (lower bound to higher bound) for the weld in NPD units. The To value must equal
or exceed the From value.
Weld_Type_From - Weld_Type_To (integer) These parameters identify the range of
weld type values (from standard note 1100). The To value must equal or exceed the From
value.
Radius_Increase (integer - NPD Units) This parameter identifies the increase to be
applied to the NPD of the weld for use in generating a cylinder to represent the construction
tolerance envelope for the weld.
Overall_Length (integer) This parameter identifies the length of the cylinder for the weld
construction tolerance envelope.

Weld Graphics Dimensions Table


This table provides the dimensions used to generate the graphical representation of welds in a
SmartPlant Review session. You may customize this table to modify the appearance of weld
graphics by weld type and diameter. The table name format that applies to this table is:
DRV_WELD_DEF

Example
Table_Data_Definition 'DRV_WELD_DEF'\
Description= WELD GRAPHICS DIMENSIONS
! TNF=G12T By=XXX Ckd By=XX Rev=0 Date= 04-Oct-2000
No_Inputs 2 No_Outputs 4
Units= NPD_IN, INT, NPD_IN, INT, DEC, DEC
! From_NPD From_Weld_Type TO_NPD To_Weld_Type Weld_Dia_Increase
Weld_Thickness_NPD_Units
2
10
7
22
0.25
0.25
6
12
10
22
0.25
0.25

168

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables


8
END

10

12

22

0.25

0.25

Parameters

From NPD - TO _NPD (integer) These parameters identify the range of nominal piping
diameters (lower bound to higher bound) for the weld in NPD units. The To value must equal
or exceed the From value.
From_Weld_Type - To_Weld_Type (integer) These parameters identify the range of
the weld type values (from standard note 1100). The To value must equal or exceed the From
value.
Weld_Dia_Increase (decimal) This parameter identifies the percentage increase to be
applied to the NPD of the weld for use in displaying a cylinder to represent the weld in
SmartPlant Review. For example, if the NPD is 6" and the increase is .25, the diameter of the
weld cylinder would be 7 1/2" (6 x 1.25 = 7.5).
Weld_Thickness (decimal) This parameter identifies the percentage to be applied to the
NPD of the weld to determine the thickness of the cylinder.
If this table is absent or if there is no NPD range encapsulating the WELD NPD, the
weld graphics dimensions will be determined as follows:
Diameter = 130% of the NPD at the weld.
Thickness = 25% of the NPD at the weld.

Gasket Diameter Table


This table is used if the pds_sort_code for the gasket spec entry is set to _GKT. The system uses
the NPD to find the gasket outside and inside diameters.
The table name format that applies to this table is:
Cmdty Code_GKT

Neutral File Format


Table_Data_Definition 'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW_GKT'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
No_Inputs 1 No_Outputs 2
Units= NPD_IN, IN, IN
!
Gasket Diameter
! NPD
Inside
Outside
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
END

Plant Design System (PDS) Reference Data Manager (PD_Data)

169

Piping Job Specification Tables

Field Fit Length Table


This table defines the pipe length adjustment for a given weld type. The weld type is determined
from the connect point data at the mating welded ends.
This table is only used if the Field Fit Length option is activated on the Material Takeoff Options
form in the Project Data Manager. MTO reads the specified table and increases the pipe length
at each welded end of the pipe based on the weld type at that specific end.

Neutral File Format


Table_Data_Definition 'Fit_Length_Table'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
No_Inputs 1 No_Outputs 1
Units= INT, IN
! Weld Type Adjust.
1
ZZZZZZZ
11
ZZZZZZZ
21
ZZZZZZZ
22
ZZZZZZZ

Component Mirror Table


This table is used for components which require non-symmetrical mirroring. It defines a mirror
option for a given Eden module. This table is called through the use of the Eden keyword
TOGGLE_<INT>, where <INT> is an integer value as defined below for Option 1.

Example
Table_Data_Definition 'Component_Mirror_Table'
No_Inputs 1 No_Outputs 3
Units= AN*6, INT, INT, INT
! Model Code
Option 1
Option 2
Option 3

Parameters

170

Model Code This column lists the model codes for components which require
non-symmetrical mirroring. The model code is used as input by the calling Eden module.
Option 1 This column represents the TOGGLE_<INT> Eden variable or specific command
instruction used to control a non symmetrical mirror operation. This column can have any of
the following values.
mirror logic in the Eden module. All items with these setting must have a tutorial
accessed in the Eden module to allow the user to change the TOGGLE during placement.
For example, if Option 1 = 1, check the TOGGLE_1 Eden variable in the Eden module to
perform specific logic to compensate for a mirrored component.
degrees instead of mirroring it.
The Model Code item will be rotated due to a specific non symmetrical definition where
there are no non symmetrical connect points involved.
the specific item.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

The item will not be mirrored due to specific non symmetrical definition. In other words,
the item is only stocked in one non symmetrical configuration which has non symmetrical
connect points involved.
Option 2 & Option 3 These columns are not currently used.

Operator Mirror Table


This table is used for operators that require non-symmetrical mirroring. It defines a mirror option
for a given Eden module. This table is called through the use of the Eden keyword
TOGGLE_<INT>, where <INT> is an integer value as defined below for Option 1.

Example
Table_Data_Definition 'Operator_Mirror_Table'
! This Table has NOT been Checked
!
No_Inputs 1 No_Outputs 3
Units= AN*6, INT, INT, INT
! Model Code
Option 1
Option 2
Option 3
OI_33
1
OI_35
1
OI_43
1
OI_53
1
A_1033
1
OP_331
1
OP_332
1
OP_333
1
OP_334
1
OP_351
1
OP_493
1000
OP_494
1000
OP_573
1000
OP_574
1000
OP_711
1000
OP_853
1000
OP_854
1000
-

Parameters

Model Code This column lists the model codes for operators which support mirroring. The
model code is used as input by the calling Eden module.
Option 1 This column represents the TOGGLE_<INT> Eden variable or specific command
instruction used to control a non symmetrical mirror operation. This column can have any of
the following values.
mirror logic in the Eden module. All items with these setting must have a tutorial
accessed in the Eden module to allow the user to change the TOGGLE during placement.
For example, if Option 1 = 1, check the TOGGLE_1 Eden variable in the Eden module to
perform specific logic to compensate for a mirrored component.
degrees instead of mirroring it.
For example, if Option 1 = 1000, the Model Code item will be rotated due to a specific non
symmetrical definition where there are no non symmetrical connect points involved.
tell the Mirror command to rotate the component 180 degrees instead of mirroring it.

Plant Design System (PDS) Reference Data Manager (PD_Data)

171

Piping Job Specification Tables

The item is only stocked in one non symmetrical configuration and does not have non
symmetrical connect points involved.
Option 2 & Option 3 These columns are not currently used.

Default End Preparation Table


The Default End Preparation Table is an optional table that can be used to automatically set the
end preparation of instruments and piping specialties that are being placed in a piping model.
The system looks for a table with the name Default_End_Prep in the spec table library.
If the table does not exist in the library, the end prep for the instrument/specialty defaults to the
end prep of the connected piping component.
If the table exists in the spec table library and the active placement point is connected to
previously placed piping or a nozzle, the end preparation for the instrument or piping specialty
is set based on entries in the table.

Example
Table_Data_Definition 'Default_End_Prep'
!
No_Inputs 1 No_Outputs 1
Units= INT, INT
!
!E_P_in
331
392
441
421

E_P_out
441
421
331
391

Data Retrieval
The system performs a table look-up using the active end preparation value. In the table above,
the last line (421 391) indicates that the end prep for an instrument/specialty connected to a
SWE (421) component will default to PE (391).
If the table does not exist in RDB, the end prep for the instrument/ specialty defaults to the end
prep of the connected piping component. In the example above, the instrument/specialty end
prep would default to SWE (421).

MTO Tables and Functions


The following special tables and functions are used by the system during Material Take-Off. Refer
to the Report Manager Reference Guide for more information on the reporting process.
field fit length tables (not currently implemented)
preferred bolt length tables
preferred bolt length roundoff factor
nut allowance table
bolt diameter and bolt pattern specification
Gasket Outside and Inside diameter tables
Bolt Length/Diameter Commodity Code tables

172

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

Piping Job Specification Tables Command


This command enables you to access the library management options for the Piping Job
Specification Table Library. You can create a new library file or create, modify, or delete data in an
existing Library. You can also create reports of the data in the library and post data from the
unapproved library to the approved library.
The spec tables for US practice are delivered in the file us_pjstb.l in the RDUSRDB product
directory.
The system tracks revision dates for table entries when a table is revised. This revision
management data is recorded in a separate Table Revision Management Library, named
<table_library>.l.r. If the library has been removed or deleted, the software regenerates the library
file.
With the 4.2 release, the limitation on the size of tables in the Piping Job Spec Table Library was
increased from approximately 16,000 bytes per table to 20,000 bytes per table.
With the 7.1 release, the limitation on the size of tables in the Piping Job Spec Table Library was
increased from approximately 20,000 bytes to 60,000 bytes or 750 lines.

Before Using This Command

Define the location of the approved and unapproved (if applicable) Piping Job Spec Table
library files in the Reference Database Management Data.
You must have write access to the specified file and directory path.

Operating Sequence
The Piping Job Specification Tables command activates the Specification Tables Library/Data
Management form used to control the contents of the spec table library.

Create Library (on page 174) used to create a new Piping Job Spec Table Library.
Compress Library (on page 174) used to compress the Piping Job Spec Table library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

173

Piping Job Specification Tables


Unapproved ==> Approved (on page 174) used to copy the unapproved Piping Job Spec
Table library to the approved library.
Create/Interactive (see "Create/Interactive Spec Tables" on page 175) used to compile
table files and add the resulting code to the Piping Job Spec Table library. You can create a
single table or specify a list of tables to be created.
Create/Batch (see "Create/Batch Spec Tables" on page 175) used to compile and add
tables to the library via batch processing.
Revise (see "Revise Spec Tables" on page 176) used to select a table from the library for
editing and compile the revised table definition.
Delete (see "Delete Spec Tables" on page 177) used to delete a specified table from the
library.
Report (see "Report on Spec Tables" on page 178) used to create a report of the library
contents.
List (see "List Spec Tables" on page 180) used to list the files contained in the library.
Extract (see "Extract Spec Tables" on page 180) used to extract a table file from the library
for editing or printing.
Refer to Default Project Control Data (on page 35) for information on defining the default location
for library files. You can also change the default file locations for each option at any time.

Create Library
This option is used to create a new Piping Job Spec Table Library. It automatically creates the
object library (.l), the text library (.l.t), and table revision management library (.l.t.r) for the library
that is being created.
The system displays the approved and unapproved Piping Job Spec Table Library names as
defined in the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Compress Library
This option is used to compress the Piping Job Spec Table library. Any tables which have been
deleted from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Piping Job Spec Table library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

174

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

Create/Interactive Spec Tables


This option enables you to compile tables and add the resulting code to the spec table library. You
can create a single table or specify a list of tables to be created.

Before Using This Command


To add more than one table to the library, create a list file in the Piping Spec Path directory which
identifies the names of the table files to be added. This file should list one filename per line with
no directory paths. All of the listed files must reside in the Piping Spec Path directory.

Operating Sequence
1. Select the Create option from the Specification Tables Library/Data Management form.

2. Set the toggle to Single to process a single table file or to List to process a list file.
3. Specify Filename for processing
Key in the name of the table file or list file to be compiled and added to the active library.
(Refer to PJS Tables and Functions (on page 135) for information on the table formats.)
4. Accept or Select Other Option
Accept the file and begin processing.

Create/Batch Spec Tables


This option enables you to load table files into the Spec Table Library as a batch operation at a
specified time.

Before Using This Command


To add more than one table file to the library, create a list file which identifies the names of the
table files to be added. The list file should contain one entry (filename) per line.

Operating Sequence
1. Select the Create/Batch option from the Specification Tables Library/Data Management
form.

2. Set the toggle to Single to process a single table file or to List to process a list file.
3. Specify Filename for Processing
Key in the name of the table file or list file to be added to the active library.
4. Accept to Submit or Set Submit Time
Set the toggle to Submit Immediately or Delayed Submit.

Plant Design System (PDS) Reference Data Manager (PD_Data)

175

Piping Job Specification Tables


For Delayed Submit, set the time to process the table files.
5. Accept the file and begin processing.

The system submits the request to the batch queue PDreference.

Revise Spec Tables


This option enables you to revise selected table files from the library. For each table to be edited,
select the table, edit the file, and then compile the table and put it back in the library. The system
updates the revision date for revised table in the Table Revision Management Library.

Operating Sequence
1. Select the Revise option from the Specification Tables Library/Data Management form.

2. Select Table for Revision.


Select the table file to be revised and select Accept.

The system extracts the specified table from the library and activates the text editor (specified
for PD_EDITOR in the control.sh file) to enable you to modify the file.

176

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library.
If an error occurs in revising a table, the editor screen is invoked automatically to give you an
opportunity to correct the problem.

The system redisplays the list of table files.


4. You can select another table to be revised as specified in step 2.

Delete Spec Tables


This option enables you to delete tables from the Piping Job Spec Table Library. It also deletes the
revision date for the table from the Table Revision Management Library.

Operating Sequence
1. Select the Delete option from the Specification Tables Library/Data Management form.

Plant Design System (PDS) Reference Data Manager (PD_Data)

177

Piping Job Specification Tables

2. Select Module Name


Select the table files to be deleted from the list of tables. You can use the scroll bar to scroll
through the available tables.
3. Select Module Name, Accept or Exit
Accept the selected tables.

The system deletes the tables from the Spec Table Library.

Report on Spec Tables


This option creates a report of information in the Spec Table Library. You can create a list file of all
the table files in the Spec Table library or create a detailed report of all the tables modified since a
specified date.

Operating Sequence
1. Select the Report option from the Specification Tables Library/Data Management form.

178

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

2. Set the toggle to Default Report to create a list file of all the table files in the library.
OR
Set the toggle to Revision Dates Report and key in a revision date to process all tables
modified since the specified revision date. The report lists the full contents of the modified
tables with individual revision dates per line.
3. Set the toggle to Report on Unapproved or Report on Approved to define the source of
information to be reported. This toggle is only displayed when both the approved and the
unapproved library are being used.
4. Accept to Form Report or Revise Report Parameters
Select Accept to form the report using the default parameters, and proceed to step 6.
OR
Key in the file information (Node Name and File Path) for the location of the neutral file to be
created.
5. Select Save, Print, or Print/Save.
For Print or Print/Save, select the print queue from the list of displayed queues. Refer to the
section on Plot and Print Queues in the Project Administrator Reference Guide for more
information on setting up multiple print queues.
If you select the Save or Print/Save option, the system creates a file named spec_tables in
the default source file location or in the location you specified.
6. Accept to Submit or Specify Submit Time
Set the toggle to Submit Immediately or Delayed Submit. For Delayed Submit, set the
time to process the request.
7. Accept to Create Report
Select Accept to create the specified report file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

179

Piping Job Specification Tables

List Spec Tables


This option displays all the tables for the Spec Table Library with the revision date of each table.

Operating Sequence
1. Select the List option from the Specification Tables Library/Data Management form.

2. You can use the scroll bar to scroll through the available tables.

Extract Spec Tables


This option enables you to extract a table file or set of table files from the Spec Table Library for
editing or printing.

Operating Sequence
1. Select the Extract option from the Specification Tables Library/Data Management form.

180

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Job Specification Tables

2. Select the tables from the list of files and select Accept. You can use the scroll bar to scroll
through the available files. You can extract multiple tables at one time.
OR
Select Extract All to to bulk extract all the tables in one operation.

The system pulls the files out of the library and places them in the default directory for Piping
Spec Data. The system also writes the names of the extracted files to a file named
PD_tbl_list.
If the list file is less than 24 hours old, the system appends the entries to the file; otherwise, it
overwrites the file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

181

SECTION 8

Graphic Commodity Data


The graphic commodity data is contained in the following object libraries:
Graphic Commodity Library (on page 183) - The delivered file
\win32app\ingr\pdshell\lib\pip_gcom.l contains parametric definitions for the components.
Physical Data Tables (on page 194) - The delivered file \win32app\ingr\rdusrdb\us_pcdim.l
contains American dimension data for components.
Piping Job Specification Tables (on page 135) - The delivered file
\win32app\ingr\rdusrdb\us_pjstb.l contains specification tables referenced in the Piping Job
Specification.
Refer to Reference Data Overview (on page 14) for an illustration of the relationships among
these libraries.
When you select a component for placement in the model, the system:
uses the active parameters (such as piping materials class and nominal diameter) to search
the Piping Job Specification (PJS) for the selected item name. If the selected item is found in
the PJS database, the system reads the PJS for the parameters required to place the
component. Included in this information is the model code (or specialty item number) for the
selected component and the names of the spec tables defined for the Piping Materials Class.
uses the model code (or specialty item number), derived from the PJS, to access the graphic
commodity library. The definitions in the graphic commodity library determine the physical
tables required to place the component and call the tables in the physical commodity library.
places the symbol graphics in the model design file and writes the nongraphic information for
the component in the database.
This section describes the graphic commodity data used in placing components in the piping
model. Refer to the Piping Design Graphics Reference Guide for a detailed description of the
actual placement process.

Additional Information
Notes for Graphic Commodity Data (on page 196)
Graphic Commodity Library Manager (on page 199)

Graphic Commodity Library


The Graphic Commodity Library (GCL) provides data for commodity items, engineered items, and
instruments. It is basically a catalog of component data which is accessed to:
determine physical data based on user specifications (such as NPD and end preparation)
assign connect point data from the Piping Job Specification
define the parametric shape for the model graphics. The Graphic Commodity Library includes
data required for model creation, resymbolization for model presentation, interference
detection, and any special functions of the Piping Job Specification, piping industry standards,
or company design practices.
PDS Piping uses the Eden Parametric Language to define and place components, specialty
items, operators, and envelopes. Eden is a high-level language (similar to FORTRAN) which
uses information from the Piping Job Specification and model to access parametric and
dimensional data.

Plant Design System (PDS) Reference Data Manager (PD_Data)

183

Graphic Commodity Data


Eden is composed of three major modules:
Symbol Processors (on page 186) and Sub-Symbol Processor (on page 187)
Physical Data Definitions (on page 187)
Parametric Shape Definitions (on page 192)
These modules are designed to carry out two functions: data definition and graphic presentation.
The data associated with these modules is delivered in the following files:
\win32app\ingr\pdshell\lib\pip_gcom.l - object library
\win32app\ingr\pdshell\lib\pip_gcom.l.t - text library
The modular approach provides for more efficient storage of information in these libraries by
enabling common information to be shared by different symbols.

184

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


The first line of each Eden module defines the type of module (such as symbol processor) and the
module name. This statement determines a two- character category code to be prefixed to the
module name in the object library. This prefix is only used by the system; it should not be
keyed-in as part of the module name.

The entries in the library use the following prefixes to identify the type of data.
SP

Symbol Processor

PD

Physical Data Definition Module

UF

User Function Module

MG

Model Parametric Shape Definition Module

DG

Detailed Parametric Shape Definition Module

Plant Design System (PDS) Reference Data Manager (PD_Data)

185

Graphic Commodity Data


IG

Interference Envelope Parametric Shape Definition


Module

SS
Sub-Symbol Processor Module
Each module must be given a unique name within the graphic commodity library. Refer to the
PDS Eden Interface Reference Guide for information on creating or modifying these modules.

Symbol Processors
A symbol processor is the controlling function or logic used to produce the graphics for a
commodity item, piping specialty, instrument, pipe support, or interference envelope. During
component placement, the symbol processor:
accesses the active component design parameters
assigns connect points
calls the required physical data modules
determines and calls the required parametric shape modules.
The system retrieves the active component parameters which are dependent upon a connect
point from the PJS in terms of green, red, or tap connect point properties. The symbol definition
assigns the data corresponding to these connect point types (green, red, or tap) to the physical
connect point numbers (CP1, CP2, CP3, CP4, or CP5).
The first line of the Eden module defines the type of module and the module name. The following
statement is used in the Eden modules to indicate a symbol processor module.
Symbol_Processor 'module name'
This statement tells the system to use the category code SP for the prefix. You should use the
following conventions in assigning the module name. The module name is determined by the
type of component being placed (commodity item or specialty item).
For a commodity item, the system searches for the New Item Name (model code) of the
commodity item as the module name. If the New Item Name is blank in the Commodity Item
entity, the system searches for the Item Name as the module name.
For a specialty item, the system searches for the specialty item name (derived from the PJS)
as the module name.
For an instrument, the system searches for the instrument name (derived from the PJS) as the
module name.
The delivered symbol processors are identified in the library with the prefix SP.
The following lists the symbol processor SPGAT which is used to control the placement of a gate
valve.
! REGULAR PATTERN, BOLTED OR MALE ENDS GATE VALVE
Symbol_Processor
'GAT'
Call Assign_Connect_Point ( GREEN, CP1 )
Call Assign_Connect_Point ( RED, CP2 )
physical_data_source = 'V1' // Standard_Type
Call Get_Physical_Data ( physical_data_source )
parametric_shape = 'V1'
Call Draw_Parametric_Shape ( parametric_shape )
Valve_Operator = DABS ( Valve_Operator )
If ( Valve_Operator .NE. 0 ) Then
If ( Valve_Operator .LT. 1000 ) Then
Subcomponent = 'OP' // Valve_Operator
Else
Subcomponent = 'A' // Valve_Operator

186

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


EndIf
Operator_Orient = FALSE
EndIf
Stop
End

Sub-Symbol Processor
A subcomponent call in a symbol processor module indicates a sub-symbol processor.
Subcomponents are additions to symbols such as an operator on a valve.
The first line of a sub-symbol processor module indicates the module type and the module name.
Sub_Symbol_Processor 'module name'
This statement tells the system to use the category code SS for the prefix.
The sub-symbol processor name for operators is a concatenation of the characters OP_ and the
modifier value from the Commodity Item entity in the PJS database. The value is expressed as a
code list number from CL550 (operator/actuator type). If the value is a positive number (such as
3) the operator is placed with the valve. If the value is a negative number (such as -3) the
operator is not placed with the valve. (This is useful in segregating large diameter valves which
almost always have a valve operator from small diameter valves which frequently do not have an
operator.)
The symbol processor for the gate valve calls a sub-symbol processor (Subcomponent = 'OP' //
Valve_Operator) which places an operator on the valve. The following depicts the sub-symbol
processor SSOP_3 which is used to control the placement of a hand wheel operator on the valve.
! HANDWHEEL OPERATOR
Sub_Symbol_Processor 'OP_3'
If ( Operator_Orient .EQ. TRUE ) Then
prompt = 1.0
Call Prompt_to_Orient_Operator ( prompt )
EndIf
physical_data_source = 'OPERATOR_3'
Call Get_Physical_Data ( physical_data_source )
parametric_shape = 'OP3'
Call Draw_Parametric_Shape ( parametric_shape )
Stop
End

Physical Data Definitions


The system uses the physical data definitions to determine the dimension data, weight data, and
surface area data using the active design parameters. Physical data modules are identified by the
statement
Physical_Data_Definition
'module name'
as the first line in the Eden module. This statement tells the system to use the category code PD
for the prefix. This prefix is only used by the system; it should not be keyed-in as part of the
module name.
The module name for a physical data module consists of a symbol type (such as V1, V2,... for
valves) and a generic type of geometric industry standard (such as AMS or DIN). You can define
multiple physical data modules for the same symbol depending on the type of standard being
referenced (for example, V1_AMS for American standards and V1_DIN for European standards).

Plant Design System (PDS) Reference Data Manager (PD_Data)

187

Graphic Commodity Data


You can manage ten different sets of logic for table naming conventions for the following industry
practices. The corresponding table suffix ranges and the suffix for the Piping Eden physical data
modules are indicated below.
Practice

Range

Suffix

U.S. Practice

1-99

AMS

European - DIN

100-199

DIN

European - British Standard

200-299

BRITISH_STD

European - Practice A

300-399

EURO_A

European - Practice B

400-499

EURO_B

International - JIS

500-599

JIS

International - Australian

600-699

AUS

International - Practice A

700-799

INT_A

International - Practice B

800-899

INT_B

Company Practice
900-999
COMPANY
The geometric industry standard for a component is defined in the Piping Commodity Data table of
the Material Reference Database. Each component must be assigned a geometric industry
standard if it is to use physical data tables.
For most of the delivered symbols, the physical data modules are classified into two categories:
specific and generic. The specific physical data module is called by the symbol processor. This
module then calls a generic physical data module.

Specific Physical Data Modules


The physical data module PDV1_AMS determines the specific dimensions (face-to-center and
face-to-face) and other physical properties for a gate valve. This is the module called by the
symbol processor SP_GAT:
Physical_Data_Definition
'V1_AMS'
physical_data_source = 'VALVE_2_AMS'
Call Get_Physical_Data ( physical_data_source )
Call Read_Table ( Table_Name_A, input, output )
Surface_Area = Output_1
Wet_Weight = Output_2
F_to_C_Dim_1 = Output_3
If ( Term_Type_1 .EQ. Term_Type_2 ) Then
F_to_C_Dim_2 = F_to_C_Dim_1
Else
F_to_C_Dim_2 = Output_4
EndIf
F_to_F_Dim = F_to_C_Dim_1 + F_to_C_Dim_2
If ( Valve_Operator .LE. 24.0 ) Then
Call Read_Table ( Table_Name_W, input, output )
Dry_Weight = Output_1
EndIf
Return
End

188

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


Generic Physical Data Modules
The generic modules contain information which is common to more than one symbol such as
flange thickness, gasket separation, and outside diameter. The physical data module V1_AMS
calls another physical data module VALVE_2_AMS which contains the generic dimension data for
all valves with two connect points.
Physical_Data_Definition
'VALVE_2_AMS'
Input_1 = Nom_Pipe_D_1
If ( Gen_Type_1 .EQ. BOLTED ) Then
table_name = 'BLT' // Term_Type_1 // Pr_Rating_1 // Gen_Flag_Green
Call Read_Table ( table_name, input, output )
Facing_OD_1 = Output_1
Thickness_1 = Output_2
Seat_Depth_1 = Output_3
Thickness_1 = Thickness_1 - Seat_Depth_1
CP_Offset_1 = Gasket_Sep_1
If ( Symbology .EQ. MODEL ) Then
Thickness_1 = 0.0
Depth_1 = 0.0
Pipe_OD_1 = 0.0
Body_OD_1 = Facing_OD_1
Else
table_name = 'MAL_300_5'
Depth_1 = Thickness_1
Input_1 = Nom_Pipe_D_1
Call Read_Table ( table_name, input, output )
Pipe_OD_1 = Output_2
Body_OD_1 = Pipe_OD_1
EndIf
Else
If ( Gen_Type_1 .EQ. MALE ) Then
table_name = 'MAL' // Term_Type_1 // Gen_Flag_Green
Call Read_Table ( table_name, input, output )
Facing_OD_1 = Output_2
Thickness_1 = 0.0
Depth_1 = 0.0
Seat_Depth_1 = 0.0
CP_Offset_1 = 0.0
Pipe_OD_1 = Facing_OD_1
Body_OD_1 = Facing_OD_1
Else
table_name = 'FEM' // Term_Type_1 // Pr_Rating_1 //
Gen_Flag_Green
Call Read_Table ( table_name, input, output )
Facing_OD_1 = Output_1
Depth_1 = Output_2
Seat_Depth_1 = 0.0
Thickness_1 = 0.0
If ( symbology .EQ. MODEL ) Then
Depth_1 = 0.0
CP_Offset_1 = 0.0
Pipe_OD_1 = 0.0
Body_OD_1 = Facing_OD_1

Plant Design System (PDS) Reference Data Manager (PD_Data)

189

Graphic Commodity Data


Else
CP_Offset_1 = -Depth_1
table_name = 'MAL_300_5'
Call Read_Table ( table_name, input, output )
Pipe_OD_1 = Output_2
Body_OD_1 = Pipe_OD_1
EndIf
EndIf
EndIf
If ( Term_Type_2 .EQ. Term_Type_1 .AND. Nom_Pipe_D_1 .EQ. Nom_Pipe_D_2
)
Then
Facing_OD_2 = Facing_OD_1
Pipe_OD_2 = Pipe_OD_1
Body_OD_2 = Body_OD_1
Thickness_2 = Thickness_1
Depth_2 = Depth_1
Seat_depth_2 = Seat_Depth_1
CP_Offset_2 = CP_Offset_1
Else
Input_1 = Nom_Pipe_D_2
If ( Gen_Type_2 .EQ. BOLTED ) Then
table_name = 'BLT' // Term_Type_2 // Pr_Rating_2 // Gen_Flag_Red
Call Read_Table ( table_name, input, output )
Facing_OD_2 = Output_1
Thickness_2 = Output_2
Seat_Depth_2 = Output_3
Thickness_2 = Thickness_2 - Seat_Depth_2
CP_Offset_2 = Gasket_Sep_2
If ( Symbology .EQ. MODEL ) Then
Thickness_2 = 0.0
Depth_2 = 0.0
Pipe_OD_2 = 0.0
Body_OD_2 = Facing_OD_2
Else
Depth_2 = Thickness_2
table_name = 'MAL_300_5'
Input_1 = Nom_Pipe_D_2
Call Read_Table ( table_name, input, output )
Pipe_OD_2 = Output_2
Body_OD_2 = Pipe_OD_2
EndIf
Else
If ( Gen_Type_2 .EQ. MALE ) Then
table_name = 'MAL' // Term_Type_2 // Gen_Flag_Red
Call Read_Table ( table_name, input, output )
Facing_OD_2 = Output_2
Thickness_2 = 0.0
Depth_2 = 0.0
Seat_Depth_2 = 0.0
CP_Offset_2 = 0.0
Pipe_OD_2 = Facing_OD_2
Body_OD_2 = Facing_OD_2
Else

190

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


table_name = 'FEM' // Term_Type_2 // Pr_Rating_2 //
Gen_Flag_Red
Call Read_Table ( table_name, input, output )
Facing_OD_2 = Output_1
Depth_2 = Output_2
Seat_Depth_2 = 0.0
Thickness_2 = 0.0
If ( Symbology .EQ. MODEL ) Then
Depth_2 = 0.0
CP_Offset_2 = 0.0
Pipe_OD_2 = 0.0
Body_OD_2 = Facing_OD_2
Else
CP_Offset_2 = -Depth_2
table_name = 'MAL_300_5'
Input_1 = Nom_Pipe_D_2
Call Read_Table ( table_name, input, output )
Pipe_OD_2 = Output_2
Body_OD_2 = Pipe_OD_2
EndIf
EndIf
EndIf
EndIf
Table_Name_A = Item_Name // Geo_Ind_Std // Term_Type_1
Table_Name_W = Commodity_Code
Input_1 = Nom_Pipe_D_1
Input_2 = Nom_Pipe_D_2
If ( Term_Type_1 .EQ. Term_Type_2 .AND. Nom_Pipe_D_1 .EQ. Nom_Pipe_D_2
)
Then
Table_Name_A = Table_Name_A // Pr_Rating_1 // 'A'
Else
If ( Gen_Type_1 .EQ. Gen_Type_2 ) Then
!
Male X Male or Bolted X
Bolted
!
or Female X Female
Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2 //
Pr_Rating_2 // 'A'
Else
If ( Gen_Type_1 .EQ. MALE ) Then
!
Male X Bolted and Male X
Female
Table_Name_A = Table_Name_A // Term_Type_2 // Pr_Rating_2 //
'A'
Else
If ( Gen_Type_2 .EQ. MALE ) Then
!
Bolted X Male and Female X
Male
Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2
//
Else
!
Bolted X Female and Female
X
Bolted

Plant Design System (PDS) Reference Data Manager (PD_Data)

191

Graphic Commodity Data


Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2
//
Pr_Rating_2 // 'A'
EndIf
EndIf
EndIf
EndIf
Return
End

Parametric Shape Definitions


The parametric shape definition describes the graphics symbol (such as bend, flange, or valve
body) which is placed for the component in the model.
Parametric shape definitions are used to place symbol graphics in the model or define
interference envelopes. This involves the following major functions
defining connect point geometry
placing connect points
moving the active location a specified distance
drawing a specific graphic shape
placing a center of gravity location.
Parametric shape definitions are divided into three basic types: model parametric shapes,
detailed parametric shapes, and interference envelopes. The first line of the Eden module
indicates the module type and the module name.

Model Parametric Shape Definitions


Model parametric shapes are used to define the symbol graphics to be placed in the model. For
example, the parametric shaped module for a valve consist of a cylinder, two cones, and a
cylinder (flange, valve body, flange).
The first line for these modules is of the form
Model_Parametric_Shape_Definition 'module name'
This statement tells the system to use the category code MG for the prefix. This prefix is only
used by the system; it should not be keyed- in as part of the module name.
The module name for a parametric shape module consists of a symbol type (such as V1, V2,... for
valves).
The parametric shape module MGV1 determines the model graphics for a valve. This is the
module called by the symbol processor SPGAT. The parametric shape module MGOP3
determines the model graphics for a hand wheel operator. This is the module called by the
sub-symbol processor SSOP_3.
Model_Parametric_Shape_Definition 'V1'
Call Define_Connect_Point_Geometry ( LINEAR )
Call Place_Connect_Point ( CP1 )
Call Move_By_Distance ( CP_Offset_1 )
Call Draw_Cylinder_With_Capped_Ends ( Depth_1, Facing_OD_1 )
length = F_to_C_Dim_1 - Thickness_1
diameter = 0.0
Call Draw_Cone ( length, Body_OD_1, diameter )
Call Place_Connect_Point ( CP0 )

192

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


Call Place_COG_Location ( DRY_COG )
Call Place_COG_Location ( WET_COG )
length = F_to_C_Dim_2 - Thickness_2
Call Draw_Cone ( length, diameter, Body_OD_2 )
Call Draw_Cylinder_With_Capped_Ends ( Depth_2, Facing_OD_2 )
Call Move_By_Distance ( CP_offset_2 )
Call Place_Connect_Point ( CP2 )
Return
End
Model_Parametric_Shape_Definition 'OP3'
Call Define_Connect_Point_Geometry ( OPERATOR )
Call Convert_NPD_to_Subunits ( Nom_Pipe_D_1, dia )
dist = dia + Min_Cyl_Dia * 0.5
angle = 90.0
radius = ( Dimension_2 - Min_Cyl_Dia ) * 0.5
Call Draw_Cylinder_With_Capped_Ends ( Dimension_1, Min_Cyl_Dia )
Call Move_by_Distance ( -dist )
Call Rotate_Orientation ( angle, Secondary )
Call Rotate_Orientation ( angle, Normal )
Call Move_Along_Axis ( -radius, Secondary )
Call Draw_Torus ( radius, angle, Min_Cyl_Dia )
Call Draw_Torus ( radius, angle, Min_Cyl_Dia )
Call Draw_Torus ( radius, angle, Min_Cyl_Dia )
Call Draw_Torus ( radius, angle, Min_Cyl_Dia )
Return
End

Detailed Parametric Shape Definition


Detailed parametric shapes are used to define more complex symbol graphics to be placed in the
model when the model symbology lock is set to detailed.
The first line for these modules is of the form
Detailed_Parametric_Shape_Definition 'module name'
This statement tells the system to use the category code DG for the prefix.

Interference Parametric Shape Definition


Interference parametric shapes are not used during component placement. They are referenced
during interference detection to determine the volume (interference envelope) to be compared for
clashes with other elements. If a clash is detected during the interference detection process, the
interference parametric shape is used to place an interference marker. Refer to the PDS
Interference Checker / Manager Reference Guide for more information on interference envelopes.
Interference_Parametric_Shape_Definition 'module name'
This statement tells the system to use the category code IG for the prefix.
If no interference module is found for a component, the system uses the model graphics
module to determine the interference parametric shape.

Plant Design System (PDS) Reference Data Manager (PD_Data)

193

Graphic Commodity Data

Physical Data Tables


The physical data tables contain the physical data (dimensions, weights, and surface area)
required for symbol creation, interference detection, stress analysis, and MTO reporting. These
tables are segregated for commodity item data, engineered item data, and instrument data. Refer
to Section 4 for a detailed description of the physical data tables and the table naming conventions
used in PDS.
The physical data tables for US Practice are delivered in the following files:
\win32app\ingr\rdusrdb\us_pcdim.l - object library
\win32app\ingr\rdusrdb\us_pcdim.l.t - text library
These libraries contain physical data for American standards. The physical data can be stored in
one of ten physical data libraries. The system uses the geometric industry standard for a particular
commodity item (or specialty item) to determine which library to reference for the physical data
tables.
Geometric industry standard is expressed as a code list value from Standard Note Type 575.
Code list numbers 2-6999 are reserved for standards that apply to American piping practices.
Code list numbers 7000-27999 are reserved for standards that apply to European piping
practices. Numbers 28000-31999 are reserved for specific company practices.
By segregating data into separate physical data libraries you can access a subset of the total
physical data available for a project. You can also build a specific set of physical data for a
particular project. The following table types are required for piping and instrument components.
Generic dimensional data
Generic tables contain data which is not specific to a particular symbol (such as flange outside
diameter or flange thickness). These tables are identified by the prefix BLT, FEM, or MAL
(for the termination type) and end with the extension .TBL (the table name is independent of
the name of the physical data module).
Specific commodity data
Specific tables contain commodity data which is specific to a particular component (such as
dimensions, water weight, and surface area). These specific tables use the model code or
commodity code as part of the table name to classify data by symbol type.
The system uses the water weight data to compute the wet weight using the specific
gravity of the operating fluid.
fluid weight = water weight * specific gravity for fluid
operating weight = dry weight + fluid weight
The surface area data enables the system to perform paint requirement calculations and
insulation weight calculations.
Specific commodity dry weight data
Piping Specialty physical data
The dimensions, dry weight, water weight, and surface area for specialty items can be stored
in a set of tables or defined at placement.
Instrument physical data
The dimensional data, dry weight, water weight, and surface area for instruments can be
stored in a set of tables or defined at placement.
You can form the name of a physical data table from attributes for the component (such as
geometry standard and end preparation). However, the table name cannot exceed 46
characters.

194

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


Additional Information
Data Retrieval from the Physical Data Library (on page 195)
Example of Physical Data Look-Up (on page 195)

Data Retrieval from the Physical Data Library


The data retrieval from tables in the Physical Data Library is restricted to two independent
variables and eight dependent variables. If only one independent variable is required, then nine
dependent variables are allowed. If more independent variables are required, the additional
independent variable(s) must be a part of the table name. If nominal diameter is one of the
independent variables, it must be listed first in the table.

Example of Physical Data Look-Up


In order to place the valve described earlier in this section, the system references the following
tables.

Generic Tables
The spec access for a six-inch gate valve defines the end preparation at both connect points as
Raised Face Flanged End (code list value 21) which is a bolted connection. As shown in the
listing for VALVE_2_AMS, the table name for a bolted connection on a two-connect point valve is
table_name= 'BLT' // Term_Type_1 // Pr_Rating_1 // Gen_Flag_Green
Using the values from the Piping Job Specification (PMC=1C0031, Item Name=6Q1C01), the
actual table name will be
BLT_20_150_5
This table returns the outside diameter, flange thickness, and the seating depth for each end of the
valve. Note that the termination type (20) is used rather than the actual end preparation value
(21).
Specific Tables
The specific tables are used to define the main body of the valve. Refer to Table Requirements (on
page 228) for an outline of the types of tables which are required to place a valve. Since the
termination type is the same at both ends of the valve (bolted), no red connect point data is
required. The required tables are found by referring to the Bolted(G) termination type.
MC_GS_Term(G)_Rat(G)_A (P15A)
MC_GS_Term(G)_Rat(G)_B (P15B) - This table is only required if more than eight outputs
are necessary to define a commodity item.
Commodity Code (P59)
Using this information, the dimension tables for a 6" gate valve are:
GAT_40_20_150_A
This table returns the face-to-center dimension for the valve. Table P15B is not required for
a gate valve.
VAABAHCCAA
This table returns the empty weight of the valve, including the weight of the operator.
If the end preparations were different at each end of the valve (such as female threaded by socket
welded) then a different set of tables would be required.
An additional table look-up is required to access the dimensional data for the valve operator. The
following table is required to define the valve operator.
MC_Type(G)_Rat(G)_Op_A (P31A)

Plant Design System (PDS) Reference Data Manager (PD_Data)

195

Graphic Commodity Data


Using this table name format, the dimension table for a hand wheel operator on a 6" gate valve is:
GAT_BLT_150_3_A
This table returns the stem length and the wheel diameter for the handwheel operator.

Notes for Graphic Commodity Data

Connect Point Data (on page 196)


Bends and Branches (on page 198)
Bolts, Gaskets, and Flanges (on page 198)
Pipe, Tubing, and Hose (on page 199)

Connect Point Data


As described in the Piping Job Specification description, connect point information for commodity
items, piping specialties, and instruments is classified in terms of green and red connect points.
The following conventions are used to coordinate the two sets of data:
For full-size components, data is only defined for the green connect point and applies to all
ends of the component.
For size change components, data for commodity items, engineered items, or instruments
should be created with the green connect point representing the larger diameter (first size) of
the component and the red connect point diameter representing the smaller diameter (second
size).
If the end preparation is different at each end of the component, the end preparation should be
defined to match the green and red connect points.
If a component has ends with the same nominal diameter but other end properties which differ,
the following rules apply:
If the ends have different end preparations (regardless of the values for
schedule/thickness) the end(s) whose end preparations have the lowest code list number
are designated as the green connect point.
If the end preparations are the same but the values for rating, schedule, or thickness
differ, the "stronger" ends(s) are designated as the green connect point.
Schedule or thickness values should be defined for all applicable components. Refer to PJS
Tables and Functions (on page 135) for a detailed description of the methods for defining the
schedule or thickness value.
A flow direction component (such as a check valve) must be defined so that the flow is directed
from connect point 1 to connect point 2.
A tee type branch must be defined with connect point three on the branch leg of the tee.

196

The origin of a component must lie between connect point 1 and connect point 2.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data

Flanges should be defined with the green connect point representing the flanged connect
point and the red connect point representing the non-flanged connect point.

A valve operator is always placed at the component origin of the corresponding valve body.

To insure consistency in pipe cut length calculations, the connect points of a component
should be located using face-to-face or face- to-center dimension rather than end-to-end or
end-to-center dimension.
A change of direction component placed by component center must be defined such that
connect point 1 is on the primary axis.

Plant Design System (PDS) Reference Data Manager (PD_Data)

197

Graphic Commodity Data

Bends and Branches

For bend components (specific and generic), the item name and the new item name must be
unique with respect to the angle of the bend. In other words, you specify the angle of the
bend by selecting the item name for the corresponding angle of the bend.
The number of joints in a miter is required to compute the stress intensification factor (SIF).
The graphics symbol description in the Graphic Commodity Library sets an attribute in the
piping design database that defines the number of joints.
For miter bend components, the system requires that the item name and the new item name
be unique with respect to the number of miter joints of the bend. In other words, the item
name specifies the number of miter joints of the bend.
For branches (tees and laterals), the system uses the first and second size to access the
branch table and determine the item name of the component to be placed at the branch point
(intersection). Depending on the active values, the branch table may define a single
component, or a set of two or three components.

Bolts, Gaskets, and Flanges

198

The data for the number of bolts and the bolt diameter is available with the flange data in the
Physical Commodity Library as a function of nominal piping diameter, pressure rating,
termination type, and geometric industry standard. However, the bolt data and the flange
data are stored in separate tables. Refer to the Report Manager Reference Guide for a
description of the table access.
A lap joint flange is defined with the end preparation at one end as flanged and the other end
as lap.
The system determines the gasket separation at each connect point of a piping component
and an instrument component by the following rules.
If the end preparation for the connect point is flanged, the gasket separation for the
connect point is set to one-half the Active Gasket Separation. However, some flanged
connections (lug, ring type joint, or wafer) have integral gaskets and do not have a gasket
separation. In this situation, the gasket separation at each connect point is set to zero.
If the end preparation for the connect point is not flanged, the gasket separation for the
connect point will be set to zero.
Flange data exists in two tables.
The first table (BLT_Term_Rat_TS) contains the flange data required for modeling
activities (such as flange outside diameter and flange thickness).
The second table (STUD_Rat_TS) contains flange data required for reporting or analysis
activities (such as bolt diameter, number of bolt holes, and nut extension).

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data

Pipe, Tubing, and Hose

All tubing (such as fiberglass and copper) is specified in terms of piping outside diameter
rather than nominal piping diameter. All commodity item data in the Alphanumeric
Commodity Library exists in terms of nominal piping diameter.
Mechanical joint and cast iron pipe can have various fixed lengths. Polypropylene-lined tube is
purchased with flanged ends in various fixed lengths.
Piping wall thickness is defined it terms of NPD units rather than model units.
A piping converter component (which converts nominal piping diameter from one system of
units to another system of units) must be defined in the PJS database for each specific pair of
nominal piping diameters. You cannot specify a convertor component for a range of nominal
piping diameters.
Flexible hose has flanged, screwed, or quick disconnect end preparations.

Graphic Commodity Library Manager


This command enables you to create a new graphic commodity library or create and modify data
(Eden modules) in an existing library. Refer to Graphic Commodity Library (on page 183) for more
information on this library.
You can compile Eden source code, review and delete object code files, and insert, extract, and
delete Eden source files from the library.
Select the Graphic Commodity Library Manager command from the Reference Data Manager
form.

Create Library (on page 200) Used to create a new Graphic Commodity Library.
Compress (on page 200) Used to compress the Graphic Commodity library.
Unapproved ==> Approved (on page 200) Used to copy the unapproved Graphic
Commodity library to the approved library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

199

Graphic Commodity Data


Create/Interactive (see "Create/Interactive Graphic Commodity Data" on page 201) Used
to compile Eden source files and insert them in the Graphic Commodity Library. You can
create a file or specify a list of files to be created.
Create/Batch (see "Create/Batch Graphic Commodity Data" on page 201) Used to compile
Eden source files and add the files to the library via batch processing. Used to compile Eden
source files via batch processing.
Revise (see "Revise Graphic Commodity Data" on page 202) Used to select an Eden
module from the library, edit the file, and put the recompiled file back into the library.
Delete (see "Delete Graphic Commodity Data" on page 204) Used to remove an Eden
module from the library.
Report (see "Report Graphic Commodity Data" on page 205) Used to create a report listing
the library contents.
List (see "List Graphic Commodity Data" on page 205) Used to display the Eden modules in
the library.
Extract (see "Extract Graphic Commodity Data" on page 206) Used to extract an Eden
module from the library for editing or printing.
You can set the toggle at the bottom of the form to determine the Eden modules to be listed.
Full List - Lists all the Eden modules in the Graphic Commodity Library.
Sub-string - Limits the list to those Eden modules which contain a specified substring.

Create Library
This option is used to create a new Graphic Commodity Library. It automatically creates the
object library (.l) and the text library (.l.t) for the library that is being created.
The system displays the approved and unapproved Graphic Commodity Library names as defined
in the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Compress
This option is used to compress the Graphic Commodity library. Any tables which have been
deleted from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Graphic Commodity library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

200

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data

Create/Interactive Graphic Commodity Data


This option enables you to compile Eden source code and add the resulting code to the graphic
commodity library. You can process a single file or specify a list of files to be created. Refer to
the description of the Graphic Commodity Library (on page 183) for information on naming
conventions for Eden modules.

Before Using This Command

Set Piping Eden Path and Piping Eden Node in the Default Project Control Data to the
location of the Eden source files.
To add more than one Eden file to the library, create a list file which identifies the names of the
Eden source files to be added. The list file should contain one entry (source file name) per line.
The list file and all of the source files should reside in the source file directory.

Operating Sequence
1. Select the Create option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
4. Key in the name of the Eden file or list file to be compiled and added to the active library.

The system verifies the existence of the specified file.


The system displays the default node name and path for the Eden modules, as specified in the
Default Project Control Data, at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
5. Accept or Select Other Option
Accept the file and begin processing.

Create/Batch Graphic Commodity Data


This option enables you to compile Eden source code and insert the specified files into the graphic
commodity library via batch processing. You can process a single file or specify a list of files to
be created. Refer to the description of the Graphic Commodity Library (on page 183) for
information on naming conventions for Eden modules.

Before Using This Command

Set Piping Eden Path and Piping Eden Node in the Default Project Control Data to the
location of the Eden source files.
To add more than one Eden file to the library, create a list file which identifies the names of the
Eden source files to be added. The list file should contain one entry (source file name) per line.
The list file and all of the source files should reside in the source file directory.

Plant Design System (PDS) Reference Data Manager (PD_Data)

201

Graphic Commodity Data


Operating Sequence
1. Select the Batch Load option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
4. Key in the name of the Eden file or list file to be compiled and added to the active library.

The system confirms the existence of the specified file.


The system displays the default node name and path for the Eden modules, as specified in the
Default Project Control Data, at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
5. Accept or Select Other Option
Set the toggle to Submit Immediately or Delayed Submit. For Delayed Submit, set the
time to process the source files.
6. Accept the file and begin processing.

The system submits the request to the batch queue PDreference.

Revise Graphic Commodity Data


This option enables you to select Eden modules from the library, edit the file, and then compile the
file and put it back in the library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the Eden modules to be listed.

Operating Sequence
1. Select the Revise option.

202

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


The system displays the Eden modules in the Graphic Commodity Library.

2. Select Module for Revision


Select the Eden modules to be revised and select Accept.

The system extracts the specified file from the library and activates the text editor (specified
for PD_EDITOR in the control.sh file) to enable you to modify the file.

3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library. (If you quit the text editor, the file will not be recompiled.)
If the file compiles successfully, the system returns to Step 2. You can select another Eden
module to be revised or select Exit.

Plant Design System (PDS) Reference Data Manager (PD_Data)

203

Graphic Commodity Data


If an error occurs in revising a Piping Eden module or table, the system invokes the editor
automatically to give you an opportunity to correct the problem.

Delete Graphic Commodity Data


This option enables you to delete Eden modules from the graphic commodity library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the Eden modules to be listed.

Operating Sequence
1. Select the Delete option.

The system displays the Eden modules in the Graphic Commodity Library.

2. Select Module for Deletion


Select the Eden modules to be deleted from the list of modules. You can use the scroll bar to
scroll through the available files.
3. Accept or Select Other Module
Accept the selected modules.

The system deletes the modules from the Graphic Commodity Library.

204

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data

Report Graphic Commodity Data


This option enables you to create a list file of all the Eden modules in the Graphic Commodity
library and their creation dates.

Operating Sequence
1. Select the Report option from the Data Management form.

2. Key in the file information for the location of the report file to be created or use the displayed
defaults.
3. Select Print or Print/Save.
Then select the print queue from the list of displayed queues. Refer to the section on Plot
and Print Queues in the Project Administrator Reference Guide for information on setting up
multiple print queues.
If you select the Print/Save option, the system will create a file named piping_eden in the
defined default source file location.
4. Accept to Form Report or Revise Report Parameters
Select Accept to create the report file.

List Graphic Commodity Data


This option displays a list of Eden modules in the Graphic Commodity Library. The display
includes:
a description of the type of Piping Eden module, such as Physical Data Definition or Model
Parametric Shape, at the end of each line.
the revision date of each Piping Eden module.
The module names are sorted alphanumerically within the list for each type of Piping Eden
module.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the Eden modules to be listed.

Operating Sequence
1. Select the List option.

Plant Design System (PDS) Reference Data Manager (PD_Data)

205

Graphic Commodity Data


The system displays the Eden modules in the Graphic Commodity Library.

2. You can use the scroll bar to scroll through the available files.
3. Select Cancel to exit the form.

Extract Graphic Commodity Data


This option enables you to extract an Eden module or set of Eden modules from the Graphic
Commodity library for editing or printing.

Before Using This Command


Set Piping Eden Path and Piping Eden Node in the Default Project Control Data to the
location of the Eden source files.
Set the toggle to Full List or Sub-string to determine the Eden modules to be listed.

206

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


Operating Sequence
1. Select Extract from the Data Management form.

2. Select EDEN Module for Extraction


Select the modules from the list of files and select Accept. You can use the scroll bar to
scroll through the available files. You can extract multiple files at one time.
OR
Select Extract ALL to bulk extract all the Piping Eden modules in one operation.

The system pulls the files out of the library and places them in the default eden directory. The
system also writes the names of the extracted files to a file named PD_gc_list.
If the list file is less than 24 hours old, the system appends the entries to the file, otherwise it
overwrites the file.

Graphic Commodity Modules List


This form allows you to select an Eden module from the library in order to revise, delete, list, or
extract the modules.
For more information, see Revise Graphic Commodity Data (on page 202), Delete Graphic
Commodity Data (on page 204), List Graphic Commodity Data (on page 205), Extract Graphic
Commodity Data (on page 206).

Plant Design System (PDS) Reference Data Manager (PD_Data)

207

Graphic Commodity Data

Physical Data Library Manager


This command enables you to access the library management options for the Physical Data
Library. You can create a new library file or create, modify, and delete data in an existing library.
You can also create reports of the data in the library and post the contents of the unapproved
library to the approved library. Refer to Physical Data Tables (on page 194) for more information
on this library.
The system tracks revision dates for table entries when a table is being revised. This revision
management data recorded in a Table Revision Management Library, named <table_library>.l.r. If
the library has been removed or deleted, the software will regenerate the library file.
This feature can be used to create revision management reports of components that require
reconstructing as a result of changes to any dimension tables since a specified date.
With the 4.2 release, the limitation on the size of tables in the Physical Data Library was increased
from approximately 16,000 bytes per table to 20,000 bytes per table.
With the 7.1 release, the limitation on the size of tables in the Physical Data Library was increased
from approximately 20,000 bytes to 60,000 bytes or 750 lines.

Before Using This Command

Define the location of the approved and unapproved (if applicable) Physical Data Library and
Spec Table Library files in the Default Project Control Data.
You must have write access to the specified file and directory path.

Operating Sequence
1. Select Physical Data Library Manager command from the Reference Data Manager form.

2. Select Table Library


Select the active practice (such as U.S. Practice or European - Din) from the display list
and select Accept.

208

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


The system loads the table list for the selected practice into memory.
3. You can set the toggle at the bottom of the form to determine the physical data tables to be
listed.
Full List lists all the tables in the Physical Data Library.
Sub-string limits the list to those tables which contain a specified substring.
4. Select Table Data Management Option
Select the option to perform.

Options

Create Library (on page 209) Used to create a new Physical Dimension Library.
Compress (on page 210) Used to compress the Physical Dimension library.
Unapproved ==> Approved (see "Unapproved to Approved" on page 210) Used to copy the
unapproved Physical Dimension library to the approved library.
Create/Interactive (see "Create/Interactive Physical Commodity Data" on page 210) Used
to process table files and add the resulting code to the active Physical Dimension library. You
can create a single table or specify a list of tables to be created.
Create/Batch (see "Create/Batch Physical Commodity Data" on page 211) Used to compile
and add table files to the active library via batch processing.
Revise (see "Revise Physical Commodity Data" on page 212) Used to select a table file
from the library for editing and put the revised file back into the library.
Delete (see "Delete Physical Commodity Data" on page 213) Used to remove a table file
from the library.
Report (see "Report Physical Commodity Data" on page 214) Used to create a report of the
library contents.
List (see "List Physical Commodity Data" on page 216) Used to display the table files in the
active library.
Extract (see "Extract Physical Commodity Data" on page 216) Used to extract a table file
from the library for editing or printing.

Create Library
This option is used to create a new Physical Dimension Library. It automatically creates the
object library (.l), the text library (.l.t), and table revision management library (.l.t.r) for the library
that is being created.
The system displays the approved and unapproved Physical Dimension Library names as defined
in the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Plant Design System (PDS) Reference Data Manager (PD_Data)

209

Graphic Commodity Data

Compress
This option is used to compress the Physical Dimension library. Any tables which have been
deleted from the library will be removed.

Unapproved to Approved
This option copies the unapproved Physical Dimension library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

Create/Interactive Physical Commodity Data


This option enables you to process physical dimension table source files and insert the specified
files into the active library. You can process a single table file or specify a list of files to be
created. Refer to the description of the applicable table file for information on naming
conventions and file formats.

Before Using This Command

Set the default table path and node in the Default Project Control Data.
To add more than one table file to the library, create a list file which identifies the names of the
table source files to be added. The list file should contain one entry (source file name) per line.
The list file and all the source files should reside in the defined default table directory.

Operating Sequence
1. Select the Create option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
Key in the name of the table file or list file to be processed and added to the active library.

The system displays the default node name and path for the table files, as specified in the
Default Project Control Data, at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
4. Accept or Select Other Option
Accept the file and begin processing.

The system processes the source file and, if successful, it stores the resulting object file in the
active library and stores the source file in the associated text library.

210

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data

Create/Batch Physical Commodity Data


This option enables you to process physical dimension table source files and insert the specified
files into the active library via batch processing. You can process a single table file or specify a
list of files to be created. Refer to the description of the applicable table file for information on
naming conventions and file formats.

Before Using This Command

Set the default table path and node in the Default Project Control Data.
To add more than one table file to the library, create a list file which identifies the names of the
table source files to be added. The list file should contain one entry (source file name) per line.
The list file and all the source files should reside in the define default table directory.

Operating Sequence
1. Select the Create option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
Key in the name of the table file or list file to be processed and added to the active library.

The system displays the default node name and path for the table files, as specified in the
Default Project Control Data, at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
4. Accept or Select Other Option
Set the toggle to Submit Immediately or Delayed Submit. For Delayed Submit, set the
time to process the source files.
5. Accept the file and begin processing.

The system submits the request to the batch queue PDreference.


The system processes the source file and, if successful, it stores the resulting object file in the
active library and stores the source file in the associated text library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

211

Graphic Commodity Data

Revise Physical Commodity Data


This option enables you to select a table file from the library, edit the file, and then put it back in the
library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the tables to be listed.

Operating Sequence
1. Select the Revise option.

The system displays the table files in the active library.

2. Select Table for Revision


Select the table files to be revised and select Accept.

212

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


The system extracts the specified file from the library and activates the text editor (specified
for PD_EDITOR in the control.sh file) to enable you to modify the file.

3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library. (If you quit the editor, the table is not recompiled.)
The system returns to Step 2. You can select another table to be revised or select Exit.

Delete Physical Commodity Data


This option enables you to delete a table file or set of table files from the active library. It also
deletes the revision dates from the corresponding Table Revision Management Library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the tables to be listed.

Operating Sequence
1. Select the Delete option.

The system displays the table files in the active library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

213

Graphic Commodity Data

2. Select Table for Deletion


Select the tables to be deleted from the list of tables. You can use the scroll bar to scroll
through the available files.
3. Accept or Select Other Option
Accept the files and begin processing.

The system deletes the table files from the active library.

Report Physical Commodity Data


This option enables you to create a report file of all the table files in the active library or those
defined by the substring search criteria.

Operating Sequence
1. Select the Report option from the Data Management form.

214

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


The system displays the reporting options on the form.

2. Revise Report Parameters


Set the toggle to Default Report to create a report that list the tables in the physical data
library.
OR
Set the toggle to Revision Dates Report and key in a date in the Revision Date field to
process all tables modified since the specified revision date. The report lists the full contents
of the modified tables with individual revision dates per line.
3. Set the toggle to Report on Unapproved or Report on Approved to define the source of
information to be reported. This toggle is only displayed when both the approved and the
unapproved library are being used.
4. Key in the file information for the location of the report file to be created.
5. Select Save, Print, or Print/Save.
Then select the print queue from the list of displayed queues. Refer to the section on Plot
and Print Queues in the Project Administrator Reference Guide for information on setting up
multiple print queues.
If you select the Save or Print/Save option, the system will create a file named
<standard>_tables in the default source file location (where <standard> is a prefix depending
on the active practice).
U.S. Practice

us

International - JIS

jis

European - DIN

din

International - Australian

aus

European - British Standard bs

International - Practice A

ina

European - Practice A

eua

International - Practice B

inb

European - Practice B

eub

Company Practice

cmp

Plant Design System (PDS) Reference Data Manager (PD_Data)

215

Graphic Commodity Data


6. Set the toggle to Submit Immediately or Delayed Submit. For Delayed Submit, set the
time to process the request.
7. Accept to Form Report or Revise Report Parameters
Select Accept to create the specified report file.

List Physical Commodity Data


This option displays all the table files for the active library with the revision date of each table.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the tables to be listed.

Operating Sequence
1. Select the List option.

The system displays the table files in the active library.

2. You can use the scroll bar to scroll through the available files.
3. Select Cancel to exit the form.

Extract Physical Commodity Data


This option enables you to extract a table file out of the active library for editing or printing.

Before Using This Command


Set the default table path and node in the Default Project Control Data.
Set the toggle to Full List or Sub-string to determine the tables to be listed.

216

Plant Design System (PDS) Reference Data Manager (PD_Data)

Graphic Commodity Data


Operating Sequence
1. Select Extract from the Data Management form.

2. Select Table for Extraction


Select the tables from the list of files and select Accept. You can use the scroll bar to scroll
through the available files.

The system pulls the files out of the library and places them in the default table directory.
The system also writes the names of the extracted files to a file named PD_tbl_list. For
example,
The current date and time is: Wed Apr 29 15:59:41 1992
File: PD_tbl2 is TDINBODY_SPECIFIC_7P1E01_I15AS_A
File: PD_tbl3 is TDINBODY_SPECIFIC_7P1E01_I15AS_B
File: PD_tbl4 is TDINBODY_SPECIFIC_7P1E01_I15AS_C
File: PD_tbl5 is TDINOPER_SPECIFIC_7P1E01_I15AS_A
File: PD_tbl6 is TDINOPER_SPECIFIC_7P1E01_I15AS_B
File: PD_tbl7 is TDINOPER_SPECIFIC_7P1E01_I15AS_C

If the list file is less than 24 hours old, the system appends the entries to the file; otherwise, it
overwrites the file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

217

SECTION 9

Table Formats and Naming Conventions


Tables are used to store data required for interactive processing of piping and instrument
components. This section describes the tables which are included in the physical data libraries.
Refer to Physical Data Tables (on page 194) for more information on these libraries. Also, refer to
Piping Job Specification Tables (on page 135) for more information on tables.

See Also
Table Conventions (on page 219)
Abbreviations (on page 227)
RDB Tables (on page 155)
Generic Tables (on page 232)
Piping Component Tables (on page 245)
Instrument Component Tables (on page 264)
Table Requirements (on page 228)

Table Conventions
Table Names
Unless otherwise indicated, values for specific and generic parameters are stored in tables whose
names are derived from parameters in the PJS. When naming ASCII files in the text libraries, if a
dot (.) or a hyphen (-) is included in the Sc/Th column of the piping job specification, the dot or
hyphen will be converted to a dollar sign ($) when the table name or ASCII file name is created.
The actual character, and not the $, is displayed in all fields representing the actual attribute
involved. The following examples illustrate how thicknesses are represented on the basis of the
above rule:
Actual Characters

ASCII equivalent

.25

$25

1.375
1$375
With version 5.0, the Physical Data Library Manager will respect the use of a dash (-) in a table
name. This allows you to include a dash in the commodity code for a piping commodity valve,
where the commodity code is used to form the name of the dimension table.
Commodity codes are read verbatim when they are used to create table names. No
conversion of dots (.) or hyphens (-), as described above, takes place. Also note that a dot (.) is
not a valid character to include in a table name. For this reason, they should not be included as
part of commodity codes for valves.

Comments
You can include any number of comments in a table, using the conventions described below:
For single-line comments:
! XXXXXXXXXXXXXXXXXXXXXXXXXX , or
< XXXXXXXXXXXXXXXXXXXXXXXXXX >

Plant Design System (PDS) Reference Data Manager (PD_Data)

219

Table Formats and Naming Conventions

For multi-line comments:


< XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX >
where XXXX... represents the comment text.

Revision Markers
Table entries preceded by a karat (>) have been revised since their original release. For
example, the section of the table shown below has been revised three times since it was first
delivered.

Component Tables
The following conventions apply to the definition of columns in all the tables except tables for
specialty items.
The following line is required to define the number of input and output columns:
No_Inputs x No_Outputs x

The number of input columns must not exceed 2. The number of output columns must not
exceed 9; it can be 0.
The following statements are used in some tables to indicate that values will be interpolated.
Input_Interpolation 1, Next_One
Input_Interpolation 2, Next_One
A definition must be made using the following format regarding the units of measure used in
each column of a table:
Units= NPD_IN, SF, LB, INT, DEC, IN, RAT, IN, IN, IN

Units
Units are defined for each column of a table as follows:

220

Angle, degrees

DEG

Angle between runs, degrees

DEC

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Area

FT2
IN2
YD2
MI2
SCM
SKM

Code-listed attributes

INT

Density

LBF3
LB_UKGAL
LB_USGAL
KIPFT3
USTONFT3
KG_L
KG_DM3
KGM3

Length, inches

IN

Length, millimeter

MM

Length, inches decimal

IN_DEC

Length, mm decimal

MM_DEC

Mass

GRAIN
USTON
UKTON
MG
G

Nominal diameter, inches

NPD_IN

Nominal diameter, mm

NPD_MM

Pressure, psig

PSIG

Pressure, pascal gage

PAG

Pressure, bar

BAR

Plant Design System (PDS) Reference Data Manager (PD_Data)

221

Table Formats and Naming Conventions


Pressure, bar (gage)

BAR_G

Pressure, atmospheres

ATM

Pressure, inches water absolute

INH20

Pressure, inches water at 32 deg

INH20_32F

Pressure, inches mercury absolute

INHG

Pressure, inches mercury at 32 deg

INHG_32F

Pressure, kg per cm squared (gage)

KG_CM2

Pressure kg per cm squared


(absolute)

KG_CM2_A

Pressure, mm water at 4 deg

MMH20

Pressure, mm mercury at 32 deg

MMHG

Pressure, megaPascal (gage)

MPa_g

Rating

RAT
CLxxx and xxx# are expressed as xxx

Schedule/thickness, inches

SC_TH_IN

Schedule/thickness, millimeters

SC_TH_MM

Stress, psi

PSI

Stress, pascal

PA

Stress, kpa

KPA

Stress, mpa

MPA

Surface area, square feet

SF

Surface area, square meter

SM

Surface area, square millimeter

SMM

Surface area/unit,

222

square feet per foot

SFF

square meter per meter

SM_M

square millimeter per meter

SMM_M

Temperature, degrees Celsius

DC

Temperature, degrees Fahrenheit

DF

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Temperature, degrees Kelvin

DK

Temperature, degrees Rankine

DR

Unitless alphanumeric

AN*xx where xx defines the number of


characters

Unitless integer

INT

Unitless real number

DEC

Weight, pounds

LB

Weight, kilogram

KG

Weight/unit, pounds per foot

LBF

Weight/unit, kilograms per meter

KGM

Fields (Input/Output Columns)

Attributes can consist of the following field types. The system determines the field type on the
basis of data provided in each table.

-NPD (for nominal diameter)

-INTEGER2

-REAL4 (floating point)

-AN*x (alphanumeric, where x defines the number of characters up to a maximum of 8)


All entries in the tables are left justified.
Field locations and field lengths defined with XXXXs, WWWWs, and ZZZZZs in this document
are observed.
Fractions are not used to define any table value.
Adjacent columns in a table are separated by one or more spaces.
If a value in a table is not known, a hyphen (-) must be used in the corresponding field. The
system interprets this entry as a blank value and displays a blank in reports, drawings, and
other data outputs.
Real numbers without decimals can be expressed with or without a decimal point. For
example, a nominal diameter of twenty inches can be expressed as 20, 20. , or 20.0. For
consistency, all delivered tables use the value 20
All alphanumeric values in a table must be enclosed in single quotes (' '). For example,
'ZZZZZ'.
For tables with only one input column, the generic value ET_AL can be used in the input
column. The system translates this entry to indicate that values in the immediately preceding
line apply to any input value equal to or greater than the value in the current line.

NPD Values
The following table is used to correlate English nominal pipe diameters with their corresponding
metric values.

Plant Design System (PDS) Reference Data Manager (PD_Data)

223

Table Formats and Naming Conventions


Nominal Pipe Diameter
inches
mm
0.125
6
0.250
8
0.375
10
0.500
15
0.750
20
1.000
25
1.250
32
1.500
40
2.000
50
2.500
65
3.000
80
3.500
90
4.000
100
5.000
125
6.000
150
8.000
200
10.00
250
12.00
300

Nominal Pipe Diameter


inches
mm
14.00
350
16.00
400
18.00
450
20.00
500
22.00
550
24.00
600
26.00
650
28.00
700
30.00
750
32.00
800
34.00
850
36.00
900
38.00
950
40.00
1000
42.00
1050
44.00
1100
46.00
1150
48.00
1200

Rating
The following conventions apply to the rating attribute with respect to the naming of data tables:
Ratings can be expressed in the PJS in any of the following formats: CLxxxx, xxxx#, or
OTxxxx. However, table entries and file names representing the rating exclude the CL, #, or
OT characters. This enables the same table to be used regardless of how the rating is
defined. In the delivered PJS, these rating formats are used in accordance with the following
criteria:
CLxxxx refers to an ANSI or API pressure rating
xxxx# refers to a pressure rating defined by an organization other than ANSI or API.
OTxxxx refers to a rating that meets the applicable ANSI or API rating geometrically but not
from a pressure carrying standpoint. An example is a valve supplied with flanged ends
meeting the bolting pattern of ANSI CL150 pressure rating but with pressure carrying
characteristics different from those of that ANSI rating.
Female ends for plastic pipe are usually defined in terms of schedule/thickness and not in
terms of rating. To make female ends for plastic pipe follow the rules for other female ends,
the applicable schedule/thickness is used as the value for rating. If such rating values
contain alphanumeric characters, the system strips all the alpha characters from the rating
value and uses only the numeric values in accessing the applicable tables.
If the rating in the PJS is expressed in alphabetic characters only, the system uses the
characters to access a data table. The names of the data tables include all the alphabetic
characters included in the PJS.
GRAVHD can be used to identify the rating for components rated to sustain a nominal fluid
head. This value can be used in the PJS and in the data tables.
OTHER can be used to identify a nonstandard rating value.
NONE can be used to identify the rating for components whose ends would normally require
the rating value as part of the table name, but for which a rating does not apply. This value
can be used in the PJS and in the data tables.

224

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Schedule/Thickness
Schedule or thickness values are shown for all applicable components. In order of preference,
schedule and thickness are expressed in terms of:
Generic schedules, such as S-STD, S-XS, and S-XXS. If the schedule name exceeds the
provided field length (for example, S-SDR13.5), it is defined in terms of its wall thickness.
Specific schedules, such as S-40, S-60, and S-80.
NREQD: This value is used in cases where all of the following conditions apply:
The thickness value is not required to purchase the component.
Empty weights are not significantly affected by actual thickness values.
Either stress analysis is not applicable, or the component is considered to be infinitely
rigid in stress analysis calculations.
Specific wall thicknesses: To insure compatibility between the data tables, the PJS, and wall
thickness calculations, thickness is expressed as defined below. Trailing zeroes are not
included. Decimal points are not included for numbers without decimals.
.xxxx if the thickness is less than 1 inch
x
if the thickness is an even inch
x.xxx if the thickness is 1 inch or larger
*Cyyy: The need to perform a thickness calculation is triggered by an entry with the format
*Cyyy in the Schedule/Thickness attribute of the Commodity Item entity. The letters that
make up this code have the following meaning:
The character C ensures that the schedule/thickness for the applicable end of the
component is determined by calculations using the thickness equation defined for the
piping materials class in the Default Wall Thickness Equation attribute of the Piping
Materials Class entity.
The characters yyy define the casting, joint or structural grade quality factor (E) times 100.
This factor is one of the parameters used in the thickness calculation. If you are defining
a calculation for a seamless fitting (E=1) but want to match the thickness for the mating
welded pipe (E=0.85), the quality factor for the pipe should be used.
MATCH: The need to match the thickness of a component to that of the pipe of the same
diameter and of option 1 is triggered by an entry with the format MATCH in the
Schedule/Thickness attribute of the Commodity Item entity.

Plant Design System (PDS) Reference Data Manager (PD_Data)

225

Table Formats and Naming Conventions


To minimize duplication when the same thickness can be expressed for metallic materials in terms
of either a generic or a specific schedule, the following convention is used. For a given nominal
diameter, only the schedules shown in the line for that diameter are used in the PJS and in the
data tables.

Weight Tables
Weight tables are required for the following thicknesses:

226

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

For components made from pipe material:


If the thickness involved is covered by a schedule, tables are required for all commercially
available schedules to the full range of their nominal diameter.
If the thickness involved is not covered by a schedule, tables are required in 1/16 inch
increments from 0.25 to 1.25 inches (inclusive), and from 22 inches to the full range of
their nominal diameter.
For components made from plate material, tables are required in 1/16 inch increments from
0.25 to 1.25 inches and in 1 inch increments from 12 to 144 inches.

Abbreviations
The following abbreviations are used to describe the table name formats in this document.
(G)

Green

(R)

Red

BrchTbl

Branch Table

Cmdty Code

Commodity Code

GCP

Green Connect Point

GS

Geometric Industry Standard (from CL575)

MC

Model Code

Op

Operator/actuator type (from CL550)

Rat

Pressure Rating

RCP

Red Connect Point

Sc/Th

Schedule/Thickness

Term

End Preparation (from CL330)

TNF

Table Name Format

TS

Table Suffix (from CL576 and CL577)

Type

Termination type (BLT, FEM, or MAL)

WC
Weight Code (from CL578)
Refer to Variables for Generic Tables (on page 232) and Variables for Specific Tables (on page
247) for a description of the variables used in table definitions. Generally, values appearing in all
uppercase characters (such as BLT or STUD) indicate a hard-coded value.

Plant Design System (PDS) Reference Data Manager (PD_Data)

227

Table Formats and Naming Conventions

Table Requirements
This section indicates which tables are required to place a particular type of component (such as a
valve or fitting). The table groups listed in this section are used to store data required for
interactive processing of piping and instrument components. The applicability of the various
table groups is defined as a function of the termination types of the components as defined in the
Piping Job Specification (PJS).
Refer to the PDS Piping Component Data Reference Guide for a detailed description of the
requirements for specific commodity items, instruments, and miscellaneous piping and instrument
items.
Typically, the tables in the table combinations are used to store:
The surface area and weight of water for the component.
The dimensional parameters for the component.
The empty weight of the component and/or data about valve operators.
Tables Required for Piping Components (on page 228)
Tables Required for Instrument Components (on page 231)

Tables Required for Piping Components


Valves (6Q1C) (on page 229)
Fittings (6P2C, 6P3C, 6Q2C, and 6Q3C) (on page 230)
Fire and Safety Piping Components (6P4C and 6Q4C) (on page 231)
Specialty Piping Components (6P6C and 6Q6C) (on page 231)

228

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Valves (6Q1C)
Termination Types
Bolted(G)
Male(G)
Female(G)
<=40)
Bolted(G)-Male(R)
Female(G)-Male(R)
<=40)
Bolted(G)-Bolted(R)
Bolted(G)-Female(R)
Female(G)-Female(R)
Female(G)-Bolted(R)
<=40)
Male(G)-Male(R)

<=40)
Male(G)-Female(R)
Male(G)-Bolted(R)
<=40)
Operators
<=24)

P15A
P15B
P59
P60A

Applicable Tables
MC_GS_Term(G)_Rat(G)_A
MC_GS_Term(G)_Rat(G)_B
Cmdty Code (if operator code <=24)
Cmdty Code_WOPD_A (if operator code >24 &

P25A
P25B
P59
P60A

MC_GS_Term(G)_Rat(G)_Term(R)_A
MC_GS_Term(G)_Rat(G)_Term(R)_B
Cmdty Code (if operator code <=24)
Cmdty Code_WOPD_A (if operator code >24 &

P26A
P26B
P59
P60A

MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_B
Cmdty Code (if operator code <=24)
Cmdty Code_WOPD_A (if operator code >24 &

P26A
P26B
P59
P60A

MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_B
Cmdty Code (if operator code <=24)
Cmdty Code_WOPD_A (if operator code >24 &

P27A
P27B
P59
P60A

MC_GS_Term(G)_Term(R)_Rat(R)_A
MC_GS_Term(G)_Term(R)_Rat(R)_B
Cmdty Code (if operator code <=24)
Cmdty Code_WOPD_A (if operator code >24 &

P31A

MC_Term(G)_Rat(G)_Op_A (if operator code

P31B

MC_Term(G)_Rat(G)_Op_B (if operator code

P60A

Cmdty Code_WOPD_A (if operator code >24 &

P60B

Cmdty Code_WOPD_B (if operator code >24 &

<=24)
<=40)
<=40)

Plant Design System (PDS) Reference Data Manager (PD_Data)

229

Table Formats and Naming Conventions

Fittings (6P2C, 6P3C, 6Q2C, and 6Q3C)


Termination Types
Male(G)

Applicable Tables
P11A
MC_GS_Term(G)_A
P11B
MC_GS_Term(G)_B
P51
MC_GS_Term(G)_Sc/Th(G)_WC
Bolted(G)
P15A
MC_GS_Term(G)_Rat(G)_A
Female(G)
P15B
MC_GS_Term(G)_Rat(G)_B
P52
MC_GS_Term(G)_Rat(G)_Sc/Th(G)_WC
Bolted(G)-Male(R)
P25A
MC_GS_Term(G)_Rat(G)_Term(R)_A
Female(G)-Male(R)
P25B
MC_GS_Term(G)_Rat(G)_Term(R)_B
P61
MC_GS_Term(G)_Rat(G)_Term(R)_Rat/Sc/Th(R)_WC
Bolted(G)-Bolted(R) P26A
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A
Bolted(G)-Female(R) P26B
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_B
Female(G)-Female(R) P62
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_Sc/Th(R)_WC
Female(G)-Bolted(R)
Male(G)-Male(R)
P21A
MC_GS_Term(G)_Term(R)_A
P21B
MC_GS_Term(G)_Term(R)_B
P63
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Sc/Th(R)_WC
Excludes olet and stubbing type fittings
Male(G)-Bolted(R)
P27A
MC_GS_Term(G)_Term(R)_Rat(R)_A
Male(G)-Female(R)
P27B
MC_GS_Term(G)_Term(R)_Rat(R)_B
P64
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat(R)_WC
Excludes olet and stubbing type fittings
Olet fittings
P28A
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_A
P28B
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_B
P65
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_WC
Stubbing fittings
P29A
MC_GS_BrchTbl_Angle_A
Overflow and weight tables do not apply.

230

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Fire and Safety Piping Components (6P4C and 6Q4C)


Termination Types
Male(G)

Applicable Tables
P11A
MC_GS_Term(G)_A
P11B
MC_GS_Term(G)_B
P51
MC_GS_Term(G)_Sc/Th(G)_WC
Bolted(G)
P15A
MC_GS_Term(G)_Rat(G)_A
Female(G)
P15B
MC_GS_Term(G)_Rat(G)_B
P52
MC_GS_Term(G)_Rat(G)_Sc/Th(G)_WC
Bolted(G)-Male(R)
P25A
MC_GS_Term(G)_Rat(G)_Term(R)_A
Female(G)-Male(R)
P25B
MC_GS_Term(G)_Rat(G)_Term(R)_B
P61
MC_GS_Term(G)_Rat(G)_Term(R)_Rat/Sc/Th(R)_WC
Bolted(G)-Bolted(R) P26A
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A
Bolted(G)-Female(R) P26B
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_B
Female(G)-Female(R) P62
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_Sc/Th(R)_WC
Female(G)-Bolted(R)
Male(G)-Male(R)
P21A
MC_GS_Term(G)_Term(R)_A
P21B
MC_GS_Term(G)_Term(R)_B
P63
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Sc/Th(R)_WC
Male(G)-Bolted(R)
P27A
MC_GS_Term(G)_Term(R)_Rat(R)_A
Male(G)-Female(R)
P27B
MC_GS_Term(G)_Term(R)_Rat(R)_B
P64
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat(R)_WC

Specialty Piping Components (6P6C and 6Q6C)


P80
P81

Specialty Body Data


Operator/Actuator Data

Tables Required for Instrument Components


The following table sets are used for instrument component classes 7P1E (Control Valves and
Regulators), 7P2C (Relief Devices), 7P3C (Other in-line Instruments), and 7Q4D (Off-Line
Instruments).
I80
Inbody_Specific_AABBCC_MC_n
Inbody_Typical_AABBCC_MC_n
I81
Inoper_Specific_AABBCC_MC_n
Inoper_Typical_AABBCC_MC_n

Plant Design System (PDS) Reference Data Manager (PD_Data)

231

Table Formats and Naming Conventions

Generic Tables
This section describes the neutral file formats used to define generic piping and instrument data.
The following tables are required to store generic data which applies to both piping and instrument
components:
TNF

Attributes Used to Form Table Name

G10

BLT_Term_Rat_TS (see "Generic Table for Bolted Ends (G10)" on page


236)

G12

STUD_Rat_TS (see "Generic Table for Studs used in Bolted Connections


(G12)" on page 237)

G12T

STUD_Term_Rat_TS (see "Generic Table for Studs in Bolted Connections


w/ Term Type (G12T)" on page 239)

G20

MAL_Term_TS (see "Generic Table for Male Ends (G20)" on page 241)

G30

FEM_Term_Rat/Sc/Th_TS (see "Generic Table for Female Ends (G30)" on


page 243)

MALWT_Term_Rat/Sc/Th_TS_WC (see "Generic Table for Weight and


Thickness Data, Male Ends (G50)" on page 244)
These tables are stored in the physical data library.
G50

Table format G14, COMPAT_Rat(low)_TS_Rat(high)_TS, which was used with the VAX
Piping Design product, is not used by the Workstation product. This table format may be
included in the physical data library but it will not be accessed by the product.

See Also
Variables for Generic Tables (on page 232)

Variables for Generic Tables


The letters P through Z are used in the generic tables to represent the following generic variables.

232

Variable

End Type

Explanation

Bolted

This is the outside diameter of a bolted end of the


indicated termination type, rating, and nominal diameter,
as defined in the table named "BLT_Term_Rat_TS".

Male

This is the outside diameter of a male end of the


indicated termination type and nominal diameter, as
defined in the table named "MAL_Term_TS".

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Variable

End Type

Explanation

Female

The is the outside diameter of the female end of the


component of the indicated termination type, rating, and
nominal diameter, as defined in the table named
"FEM_Term_Rat_TS". For model graphics, it is
desirable for the value of this parameter to be larger
than the value of the matching male termination end.
However, components such as 90 degree elbows and
tees will not place if the value is too large. Therefore,
the following values have been defined for this
parameter:
For PVC and CPVC female ends, use the same as the
value of P for the corresponding male termination type.
For all other female ends, use 30% of the fitting OD at
the female end plus 70% of the matching pipe OD.

Bolted

Not applicable.

Male

The value of this variable is "0" for all male ends.

Female

This is the depth of socket, as defined in the table


named "FEM_Term_Rat_TS".
For socketwelded ends, this value is the nominal depth
of the socket less 1/16". The actual depth of socket
less 1/16" is used to determine a component's
dimensional parameters.
For female threaded ends, this is the thread
engagement as defined: in Table 8-1 for components
complying with ANSI-B16.12 and in Table 8-2 for all
other components.

Plant Design System (PDS) Reference Data Manager (PD_Data)

233

Table Formats and Naming Conventions


Variable

End Type

Explanation

Bolted

This is the flange thickness, as defined in the table


named "BLT_Term_Rat_TS". This dimension
represents the distance from the outermost face of the
flange to the back surface of the flange on which the nut
rests. It includes any projections of the flange, such as
the raised face.
For lap-flanged ends, it includes the thickness of the
pipe or stub end plus the thickness of the loose flange
used. If the Source of Bolt Spec Data is set as a
function of termination type, rating, and table suffix in the
RDB, the entries for the lap type terminations in the
BLT_Term* and STUD_Term* generic tables provide for
the addition of wall thickness from the TDB.
This parameter is primarily used to calculate stud length.
When dealing with specialty components (such as relief
valves), you might have to develop many generic tables
for precise values. A practical alternative would be to
create a table in which values for this parameter are
large enough to insure that short studs do not result.

234

Male

Not applicable.

Female

Not applicable.

Bolted

This is the seating depth, as defined in the table named


"BLT_Term_Rat_TS". This dimension represents the
distance from the outermost surface of the bolted end to
the seating surface of the gasket. It will only have a
value for small groove, large groove, small female and
large female flanged ends, and for mechanical joints.
The value of this parameter will be zero for all other
bolted ends.

Male

Not applicable.

Female

Not applicable.

Bolted

This is half of the gasket gap thickness, as defined in the


PJS for the applicable piping materials class.

Male

Not applicable.

Female

Not applicable.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Variable

End Type

Explanation

Bolted

This is the diameter of bolts required at a bolted


connection, as defined in the table named
"STUD_Rat_TS" as a function of the nominal pipe
diameter, rating, and table suffix of the applicable bolted
end.

Male

Not applicable.

Female

Not applicable.

Bolted

Not applicable.

Male

This is the wall thickness of the applicable end of a


component of the indicated nominal diameter, as
defined in the table named
"MALWT_Term_Sc/Th_TS_WC".

Female

Not applicable.

Any

No specific meaning is attached to this variable.

Table 8-1. Thread Engagement for


Components per ANSI-B16.12
NPD in
1.25
1.5
2
2.5
3
4
5
6
8

Thread Engagement, inches


ANSI-B16.12
PDS
0.42
0.42
0.42
0.42
0.44
0.44
0.68
0.68
0.77
0.77
0.84
0.84
0.94
0.94
0.96
0.96
1.06
1.06

Table 8-2. Thread Engagement for All Other Components


Thread Engagement, inches
NPD in NAVCO
0.125
0.25
0.375
0.5

0.3125
0.4375
0.4375
0.5625

ANSI-B1.
20.1
0.2726
0.3945
0.4067
0.5343

Stockham

Crane

Average

PDS

0.25
0.375
0.375
0.5

0.25
0.375
0.375
0.5

0.2713
0.3955
0.3986
0.5242

0.25
0.375
0.375
0.5

Plant Design System (PDS) Reference Data Manager (PD_Data)

235

Table Formats and Naming Conventions


0.75
1
1.25
1.5
2
2.5
3
3.5
4
5
6
8
10
12

0.5625
0.6875
0.6875
0.6875
0.75
1.0625
1.125
1.1875
1.1875
1.3125
1.3751
1.4375
1.625
1.75

0.5533
0.6609
0.6809
0.6809
0.6969
0.932
1.016
1.071
1.094
1.187
1.208
1.313
1.46
1.61

0.5625
0.6875
0.6875
0.6875
0.75
0.9375
1

0.5625
0.6875
0.6875
0.6875
0.75
0.9375
1
1.0625
1.125
1.25
1.3125
1.4375
1.625
1.75

0.5602
0.6809
0.6859
0.6859
0.7367
0.9674
1.0353
1.107
1.1355
1.2483
1.2985
1.396
1.57
1.7033

0.5625
0.6875
0.6875
0.6875
0.75
0.9375
1
1.0625
1.125
1.25
1.3125
1.4375
1.5625
1.75

Generic Table for Bolted Ends (G10)


This table enables you to define the outside diameter, flange thickness, seating depth, and bolt
circle diameter for components with bolted ends.
The table name format for this table is:
For TNF=G10 BLT_Term_Rat_TS

Neutral File Format


Table_Data_Definition
'BLT_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G10
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 4
Units= NPD_IN, IN, IN, IN, IN
! Diam
P
R
S
BCD
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
END

Example
Table_Data_Definition 'BLT_20_150_5'
! Description= CL150 raised face flange dimensions
! Source= MSS-SP-42 1/4 & 3/8", ANSI-B16.5-1981 1/2" - 24" & API 605 above
24"
! TNF=G10
By=GJH
Ckd By=RJW
Rev=1
Date=15-Oct-1987

236

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


No_Inputs 1 No_Outputs 4
Units= NPD_IN, IN, IN, IN, IN
! Diam
P
R
S
0.25
2.5
0.3438
0
0.375 2.5
0.3438
0
0.5
3.5
0.4375
0
0.75
3.875
0.5
0
1
4.25
0.5625
0
1.25
4.625
0.625
0
1.5
5
0.6875
0
2
6
0.75
0
2.5
7
0.875
0
3
7.5
0.9375
0
3.5
8.5
0.9375
0
4
9
0.9375
0
5
10
0.9375
0
6
11
1
0
8
13.5
1.125
0
10
16
1.1875
0
12
19
1.25
0
14
21
1.375
0
16
23.5
1.4375
0
18
25
1.5625
0
20
27.5
1.6875
0
24
32
1.875
0
26
30.9375 1.625
0
28
32.9375 1.75
0
30
34.9375 1.75
0
32
37.0625 1.8125
0
34
39.5625 1.9375
0
36
41.625
2.0625
0
38
44.25
2.125
0
40
46.25
2.1875
0
42
48.25
2.3125
0
44
50.25
2.375
0
46
52.8125 2.4375
0
48
54.8125 2.5625
0
50
56.8125 2.6875
0
52
58.8125 2.75
0
54
61
2.8125
0
56
63
2.875
0
58
65.9375 2.9375
0
60
67.9375 3
0
END

BCD
1.6875
1.6875
2.375
2.75
3.125
3.5
3.875
4.75
5.5
6
7
7.5
8.5
9.5
11.75
14.25
17
18.75
21.25
22.75
25
29.5
29.3125
31.3125
33.3125
35.4375
37.6875
39.75
42.125
44.125
46.125
48.125
50.5625
52.5625
54.5625
56.5625
58.75
60.75
63.4375
65.4375

Generic Table for Studs used in Bolted Connections (G12)


This table defines the number of bolts, the bolt diameter, and the bolt extension for a given NPD,
for studs in bolted connections. If the Length Calculation toggle on the Material Takeoff
Option form is set to Almost Precise in Project Administrator, the bolt spec data is set as a
function of rating and table suffix.
The W_n columns are used to classify the bolt extension. The n applies to the value defined in
the Piping Commodity Data for the bolt diameter being considered. For example, if the modifier
value for the PCD is 0, the value in the W_0 column is used for nut allowance. This capability

Plant Design System (PDS) Reference Data Manager (PD_Data)

237

Table Formats and Naming Conventions


enables the system to handle special nut allowances, such as when stud tensioning devices are
utilized.
The table name format for this table is:
For TNF=G12 STUD_Rat_TS
This table is accessed using values for rating and table suffix derived from the applicable flanged
end.

Neutral File Format


Table_Data_Definition
'STUD_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G12
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, INT, IN, IN, IN, IN, IN, IN, IN
! Diam
U
V
W_0
W_1
W_2
W_3
W_4
W_5
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Example
Table_Data_Definition
'STUD_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G12
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, INT, IN, IN, IN, IN, IN, IN, IN

238

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


! Diam
W_5
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
END

W_0

W_1

W_2

W_3

W_4

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

Generic Table for Studs in Bolted Connections w/ Term Type


(G12T)
This table defines the number of bolts, the bolt diameter, and the bolt extension for a given NPD,
for studs in bolted connections. If the Length Calculation toggle on the Material Takeoff
Option form is set to Precise in Project Administrator, the bolt spec data is set as a function of
termination type, rating, and table suffix.
The W_n columns are used to classify the bolt extension. The n applies to the value defined in
the Piping Materials Class for the bolt diameter being considered. For example, if the modifier
value for the PMC is 0, the value in the W_0 column is used for nut allowance. This capability
enables the system to handle special nut allowances, such as when stud tensioning devices are
utilized.
The table name format for this table is:
STUD_Term_Rat_TS
This table is accessed using values for termination type, rating and table suffix derived from the
applicable flanged end.

Neutral File Format


Table_Data_Definition
'STUD_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source= PIPING RDB DATA MANUAL
! Parameter W_2 equals 50% of applicable stud diameter plus W_0.
! TNF=G12T
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, INT, IN, IN, IN, IN, IN, IN, IN
! Diam
U
V
W_0
W_1
W_2
W_3
W_4
W_5

Plant Design System (PDS) Reference Data Manager (PD_Data)

239

Table Formats and Naming Conventions


WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
END

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

Example
Table_Data_Definition 'STUD_20_150_5'
! Description= CL150 bolting
! Source= PIPING RDB DATA MANUAL
! Parameter W_2 equals 50% of applicable stud diameter plus W_0.
! TNF=G12T
By=GJH
Ckd By=NP
Rev=0
Date=04-Oct-1989
No_Inputs 1 No_Outputs 8
Units= NPD_IN, INT, IN, IN, IN, IN, IN, IN, IN
! Diam
U
V
W_0
W_1
W_2
W_3
W_4
W_5
0.5
4
0.5
0.625
1
0.75
4
0.5
0.6875
0.875
1
4
0.5
0.625
1
1.25
4
0.5
0.6875
0.875
1.5
4
0.5
0.625
1
2
4
0.625
0.8125
1.125
2.5
4
0.625
0.8125
1.125
3
4
0.625
0.75
1
3.5
8
0.625
0.75
1
4
8
0.625
0.75
1
5
8
0.75
0.875
1.25
1.25
6
8
0.75
0.9375
1.125
1.3125
8
8
0.75
0.9375
1.125
1.3125
10
12
0.875
1
1.5
1.4375
12
12
0.875
1.0625
1.375
1.5
14
12
1
1.1875
1.625
1.6875
16
16
1
1.125
1.5
1.625
18
16
1.125
1.25
1.75
1.8125
20
20
1.125
1.375
2
1.9375
24
20
1.25
1.4375
2.125
2.0625
26
36
0.75
1.0625
1.375
1.4375
28
40
0.75
1.0625
1.375
1.4375
30
44
0.75
1.0625
1.375
1.4375
-

240

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
END

48
40
44
40
44
48
52
40
44
48
52
56
60
48
52

0.75
0.875
0.875
1
1
1
1
1.125
1.125
1.125
1.125
1.125
1.125
1.25
1.25

1
1.125
1.125
1.3125
1.25
1.25
1.3125
1.5
1.375
1.375
1.4375
1.375
1.4375
1.5
1.5625

1.5
1.75
1.75
1.875
2
1.75
1.875
2
2
2
2.125
2
2.125
2.25
2.125

1.375
1.5625
1.5625
1.8125
1.75
1.75
1.8125
2.0625
1.9375
1.9375
2
1.9375
2
2.125
2.1875

Generic Table for Male Ends (G20)


This table enables you to define the surface area, water weight, outside diameter, and 1/2 pipe OD
for components with male ends.
The table name format for this table is:
For TNF=G20 MAL_Term_TS

Neutral File Format


Table_Data_Definition
'MAL_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G20
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 3
Units= NPD_IN, SFF, IN, IN
!
Unt Sur
! Diam
Area
P
P/2
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
END

Example
Table_Data_Definition 'MAL_300_5'
! Description= Pipe outside diameters
! Source= ANSI-B-36.10M, 36.19M, API-5L, 5LE, 5LP, 5LS & 5LU

Plant Design System (PDS) Reference Data Manager (PD_Data)

241

Table Formats and Naming Conventions


! TNF=G20
By=GJH
Ckd By=RJW
Date=10-Sep-1987
No_Inputs 1 No_Outputs 3
Units= NPD_IN, SFF, IN, IN
!
Unt Sur
! Diam
Area
P
P/2
0.125 0.106
0.405
0.2025
0.25
0.141
0.54
0.27
0.375 0.177
0.675
0.3375
0.5
0.22
0.84
0.42
0.75
0.275
1.05
0.525
1
0.344
1.315
0.6575
1.25
0.434
1.66
0.83
1.5
0.497
1.9
0.95
2
0.622
2.375
1.1875
2.5
0.753
2.875
1.4375
3
0.916
3.5
1.75
3.5
1.047
4
2
4
1.178
4.5
2.25
5
1.456
5.5625
2.7813
6
1.73
6.625
3.3125
8
2.26
8.625
4.3125
10
2.81
10.75
5.375
12
3.34
12.75
6.375
14
3.67
14
7
16
4.19
16
8
18
4.71
18
9
20
5.24
20
10
22
5.76
22
11
24
6.28
24
12
26
6.81
26
13
28
7.33
28
14
30
7.85
30
15
32
8.38
32
16
34
8.9
34
17
36
9.42
36
18
38
9.95
38
19
40
10.47
40
20
42
10.99
42
21
44
11.52
44
22
46
12.04
46
23
48
12.57
48
24
52
13.61
52
26
56
14.66
56
28
60
15.71
60
30
64
16.76
64
32
68
17.80
68
34
72
18.85
72
36
76
19.90
76
38
80
20.94
80
40
END

242

Rev=0

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Generic Table for Female Ends (G30)


This table enables you to define the outside diameter and depth of socket for female ends.
The table name format for this table is:
For TNF=G30 FEM_Term_Rat/Sc/Th_TS

Neutral File Format


Table_Data_Definition
'FEM_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G30
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 2
Units= NPD_IN, IN, IN
! Diam
P
Q
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ
END

Example
Table_Data_Definition 'FEM_420_150_5'
! Description= CL150 socketwelded flange hub O.D. and socketwelded valve
O.D.
! Source= ANSI-B16.11 CL3000 for .125 to .375 dia's, ANSI-B16.5 above .375
dia.
! TNF=G30
By=GJH
Ckd By=JPF
Rev=0
Date=29-May-1986
No_Inputs 1 No_Outputs 2
Units= NPD_IN, IN, IN
! Diam
P
Q
0.125 0.486
0.3125
0.25
0.6353
0.3125
0.375 0.7755
0.3125
0.5
0.9443
0.3125
0.75
1.185
0.375
1
1.5018
0.4375
1.25
1.8558
0.5
1.5
2.0988
0.5625
2
2.5813
0.625
2.5
3.0813
0.6875
3
3.725
0.75
END

Plant Design System (PDS) Reference Data Manager (PD_Data)

243

Table Formats and Naming Conventions

Generic Table for Weight and Thickness Data, Male Ends


(G50)
This table enables you to define empty weight and wall thickness data for male ends.
The table name format for this table is:
For TNF=G50 MALWT_Term_Rat/Sc/Th_TS_WC

Neutral File Format


Table_Data_Definition
'MALWT_WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=G50
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 3
Units= NPD_IN, LBF, LBF, IN
! GCP
Unit Wt Unit Wt
! Diam
Empty
Water
X
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ
END

Example
Table_Data_Definition 'MALWT_300_S$40_5_52'
! Description= Schedule 40 wall thickness
! Source= ANSI-B36.10M-1985
! TNF=G50
By=GJH
Ckd By=RJW
Rev=0
Date=10-Sep-1987
No_Inputs 1 No_Outputs 3
Units= NPD_IN, LBF, LBF, IN
! GCP
Unit Wt Unit Wt
! Diam
Empty
Water
X
12
53.52
48.5
0.406
14
63.44
58.63
0.438
18
104.67
96.92
0.562
20
123.11
120.45
0.594
24
171.29
174.22
0.688
32
230.08
319.2
0.688
34
244.77
362.25
0.688
36
282.35
405.09
0.75
END

244

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Piping Component Tables


This section describes the table formats used to define component data. The following tables are
required to store component-specific data required for interactive processing of piping
components:
These tables are stored in the physical data library.
Use tables P11*-P20* for piping component data based only on green connect point data.
TNF

Attributes Used to Form Table Name

P11A

MC_GS_Term(G)_A (see "Piping


Component Table for GCP Data (P11A,
P15A)" on page 251)

P11B

MC_GS_Term(G)_B (see "Piping


Component Table GCP Overflow Data
(P11B, P15B)" on page 252)

P15A

MC_GS_Term(G)_Rat(G)_A

P15B
MC_GS_Term(G)_Rat(G)_B
Use tables P21*-P30* for piping component data based on green and red connect point data.
For more information, refer to Piping Component Table Green and Red CP Data (P21A, P25A,
P26A, P27A, P28A, P29A) (on page 253) and Piping Component Table Green and Red CP
Overflow Data (P21B, P25B, P26B, P27B, P28B) (see "Piping Component Table Green and Red
CP Overflow Data (P21B,P25B,P26B,P27B,P28B)" on page 255).
TNF

Attributes Used to Form Table Name

P21A

MC_GS_Term(G)_Term(R)_A

P21B

MC_GS_Term(G)_Term(R)_B

P25A

MC_GS_Term(G)_Rat(G)_Term(R)_A

P25B

MC_GS_Term(G)_Rat(G)_Term(R)_B

P26A

MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)
_A

P26B

MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)
_B

P27A

MC_GS_Term(G)_Term(R)_Rat(R)_A

P27B

MC_GS_Term(G)_Term(R)_Rat(R)_B

P28A

MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/
Sc/Th(R)_A

P28B

MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/
Sc/Th(R)_B

P29A
MC_GS_BrchTbl_Angle_A
Use tables P31*-P40* for dimensional data based on green connect point data of piping valve
operators whose operator code list values (as defined in CL550 - Operator/Actuator Type) are
equal to or less than 24.

Plant Design System (PDS) Reference Data Manager (PD_Data)

245

Table Formats and Naming Conventions


TNF

Attributes Used to Form Table Name

P31A

MC_Type(G)_Rat(G)_Op_A (see "Piping


Component Table for Operators and
Actuators (P31A)" on page 256)

MC_Type(G)_Rat(G)_Op_B (see "Piping


Component Table for Operators and
Actuators, Overflow Data (P31B)" on page
257)
Use tables P51-P58 for non-valve piping component empty weights based on green connect point
data.
P31B

TNF

Attributes Used to Form Table Name

P51

MC_GS_Term(G)_Sc/Th(G)_WC (see
"Piping Component Table for Empty Weight
based on GCP Data (P51,P52,P59)" on page
258)

P52
MC_GS_Term(G)_Rat(G)_Sc/Th(G)_WC
Use table P59 for empty weights of piping valves, including weight of operators, whose operator
code list values (as defined in CL550 - Operator/Actuator Type) are less than or equal to 24,
regardless of whether only green connect point or both green and red connect point data applies
to the valve.
P59
Cmdty Code
Use tables P60* for empty weights of piping valves, weights and centers of gravity of valve
operators, model codes of valve operators and for dimensional data of piping valve operators
whose operator code list values (as defined in CL550 - Operator/Actuator Type) exceed 24 and
are less than or equal to 40, regardless of whether only green connect point or both green and red
connect point data applies to the valve.
P60A

Cmdty Code_WOPD_A
(see "Piping Component
Table For Empty Weight
of Valves (P60A)" on
page 260)

Cmdty Code_WOPD_B
(see "Piping Component
Table For Empty Weight
of Valves, Overflow Data
(P60B)" on page 261)
Use tables P61-P70 for non-valve piping component empty weights based on green and red
connect point data. Refer to Piping Component Table for Empty Weight based on GCP and RCP
Data (P61, P62, P63, P64, P65) (see "Piping Component Table for Empty Weight based on GCP
and RCP Data (P61,P62,P63,P64,P65)" on page 263) for more information.
P60B

246

TNF

Attributes Used to Form Table Name

P61

MC_GS_Term(G)_Rat(G)_Term(R)_Rat/Sc/Th(R)_WC

P62

MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_Sc/Th(R)_WC

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


TNF

Attributes Used to Form Table Name

P63

MC_GS_Term(G)_Sc/Th(G)_Term(R)_Sc/Th(R)_WC

P64

MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat(R)_WC

P65

MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_WC

Use tables P80 and P81 for data about piping specialty components defined in the Material
Reference Database. See Piping Component Tables for Specialty Components (on page 264) for
more information.
P80

Specialty Body Data

P81

Operator/Actuator
Data

See Also
Variables for Specific Tables (on page 247)

Variables for Specific Tables


Letters A through O represent variables which are specific to a component.
Variable

End Type

Explanation

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this is the distance from the
origin of the component to the outermost face of
any of its ends.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to the outermost face of the end in
the vicinity of PCP1.

Bolted

This value is included in the appropriate dimension


table.

Male

Not applicable.

Female

This value can be deduced from the expression E +


Q using the values of E and Q from the appropriate
tables.

Plant Design System (PDS) Reference Data Manager (PD_Data)

247

Table Formats and Naming Conventions


Variable

End Type

Explanation

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to the outermost face of the end in
the vicinity of PCP2.

Bolted

This value is included in the appropriate dimension


table.

Male

Not applicable.

Female

This value can be deduced from the expression F +


Q using the values of F and Q from the appropriate
tables.

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to the outermost face of the end in
the vicinity of PCP3.

Bolted

This value is included in the appropriate dimension


table.

Male

Not applicable.

Female

This value can be deduced from the expression G


+ Q using values of G and Q from the appropriate
tables.

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to the outermost face of the end in
the vicinity of PCP4.

Bolted

248

This value is included in the appropriate dimension


table.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Variable

End Type

Explanation

Male

Not applicable.

Female

This value can be deduced from the expression H


+ Q using values of H and Q from the appropriate
tables.

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this is the distance from the
origin of the component to any of its PCPs.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to PCP1.

Bolted

This parameter can be deduced from the


expression A + T using the values of A and T from
the appropriate tables.

Male

This value is included in the appropriate dimension


table.

Female

This value is included in the appropriate dimension


table.

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to PCP2.

Bolted

This parameter can be deduced from the


expression B + T using the values of B and T from
the appropriate tables.

Male

This value is included in the appropriate dimension


table.

Female

This value is included in the appropriate dimension


table.

Plant Design System (PDS) Reference Data Manager (PD_Data)

249

Table Formats and Naming Conventions


Variable

End Type

Explanation

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to PCP3.

Bolted

This parameter can be deduced from the


expression C + T using values of C and T from the
appropriate tables.

Male

This value is included in the appropriate dimension


table.

Female

This value is included in the appropriate dimension


table.

Any

For components with identical end terminations


and branches (if any) that are normal to the main
axis of the component, this parameter does not
apply.
For components with different end terminations or
branches that are not normal to the main axis of the
component, this is the distance from the origin of
the component to PCP4.

250

Bolted

This parameter can be deduced from the


expression D + T using the values of D and T from
the appropriate tables.

Male

This value is included in the appropriate dimension


table.

Female

This value is included in the appropriate dimension


table.

I,J,K,L,M,N Any

These values are used in dimension tables for


specific components as required by the component
being defined.

This is the overall length of the component


considering the outermost surface at each end of
the component.

Any

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Piping Component Table for GCP Data (P11A, P15A)


This table enables you to define general parameters for components which require only green
connect point data.
The table name formats for this table are:
For TNF=P11A MC_GS_Term(G)_A For TNF=P15A MC_GS_Term(G)_Rat(G)_A

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
Par 6=ZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, SF, LB, IN, IN, IN, IN, IN, IN
! GCP
Surf
Water
Dimensional Parameters
! Diam
Area
Weight
Par 1
Par 2
Par 3
Par 4
Par 5
Par 6
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Example
Table_Data_Definition 'GAT_40_20_150_A'
! Description= CL150 gate valve raised face flanged ends
! Source= ANSI-B16.10-1986
! TNF=P15A
By=GJH
Ckd By=RJW
Rev=1
Date=29-Oct-1987
! SN=V1
Par 1=A
No_Inputs 1 No_Outputs 3
Units= NPD_IN, SF, LB, IN
! GCP
Surf
Water
Dimensional Parameters
! Diam
Area
Weight
Par 1
0.25
2
0.375 2
0.5
2.125
0.75
2.3125

Plant Design System (PDS) Reference Data Manager (PD_Data)

251

Table Formats and Naming Conventions


1
1.25
1.5
2
2.5
3
4
5
6
8
10
12
14
16
18
20
24
26
28
30
36
END

2.5
2.75
3.25
3.5
3.75
4
4.5
5
5.25
5.75
6.5
7
7.5
8
8.5
9
10
11
12
12
14

Piping Component Table GCP Overflow Data (P11B, P15B)


This table enables you to define overflow parameters for components to which table name formats
P11A and P15A apply.
The table name formats for this table are:
For TNF=P11B MC_GS_Term(G)_B For TNF=P15B MC_GS_Term(G)_Rat(G)_B

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
Par 6=ZZ
Par 7=ZZ
Par 8=ZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, IN, IN, IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Par 1
Par 2
Par 3
Par 4
Par 5
Par 6
Par 7
Par 8
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ

252

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
END

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

Piping Component Table Green and Red CP Data (P21A,


P25A, P26A, P27A, P28A, P29A)
This table enables you to define parameters for components which require both green and red
connect point data.
The table name formats for this table are:
TNF=P21A MC_GS_Term(G)_Term(R)_A TNF=P25A
MC_GS_Term(G)_Rat(G)_Term(R)_A TNF=P26A
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A TNF=P27A
MC_GS_Term(G)_Term(R)_Rat(R)_A TNF=P28A
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_A TNF=P29A
MC_GS_BrchTbl_Angle_A

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
No_Inputs 2 No_Outputs 7
Units= NPD_IN, NPD_IN, SF, LB, IN, IN, IN, IN, IN
!
Nom Diam
Surf
Weight
Dimensional Parameters
! GCP
RCP
Area
Water
Par 1
Par 2
Par 3
Par 4
Par 5
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Example
Table_Data_Definition 'E90R_39_300_300_A'
! Description= 90 deg long radius reducing elbow beveled ends

Plant Design System (PDS) Reference Data Manager (PD_Data)

253

Table Formats and Naming Conventions


! Source= ANSI-B16.9-1978
! TNF=P21A
By=GJH
Ckd By=JPF
Rev=0
Date=15-May-1986
! SN=F84
Par 1=E
Par 2=K
Par 3=F
Par
No_Inputs 2 No_Outputs 6
Units= NPD_IN, NPD_IN, SF, LB, IN, IN, IN, IN
!
Nom Diam
Surf
Weight
Dimensional Parameters
! GCP
RCP
Area
Water
Par 1
Par 2
Par 3
2
1
3
0.53
3
2
1.25
3
0.3575
3
2
1.5
3
0.2375
3
2.5
1.25
3.75
0.6075
3.75
2.5
1.5
3.75
0.4875
3.75
2.5
2
3.75
0.25
3.75
3
1.5
4.5
0.8
4.5
3
2
4.5
0.5625
4.5
3
2.5
4.5
0.3125
4.5
3.5
2
5.25
0.8125
5.25
3.5
2.5
5.25
0.5625
5.25
3.5
3
5.25
0.25
5.25
4
2
6
1.0625
6
4
2.5
6
0.8125
6
4
3
6
0.5
6
4
3.5
6
0.25
6
5
2.5
7.5
1.3438
7.5
5
3
7.5
1.0313
7.5
5
3.5
7.5
0.7813
7.5
5
4
7.5
0.5313
7.5
6
3
9
1.5625
9
6
3.5
9
1.3125
9
6
4
9
1.0625
9
6
5
9
0.5312
9
8
4
12
2.0625
12
8
5
12
1.5312
12
8
6
12
1
12
10
5
15
2.5937
15
10
6
15
2.0625
15
10
8
15
1.0625
15
12
6
18
3.0625
18
12
8
18
2.0625
18
12
10
18
1
18
14
8
21
2.6875
21
14
10
21
1.625
21
14
12
21
0.625
21
16
10
24
2.625
24
16
12
24
1.625
24
16
14
24
1
24
18
10
27
3.625
27
18
12
27
2.625
27
18
14
27
2
27
18
16
27
1
27
20
10
30
4.625
30
20
12
30
3.625
30
20
14
30
3
30

254

4=L

Par 4
0.53
0.3575
0.2375
0.6075
0.4875
0.25
0.8
0.5625
0.3125
0.8125
0.5625
0.25
1.0625
0.8125
0.5
0.25
1.3438
1.0313
0.7813
0.5313
1.5625
1.3125
1.0625
0.5312
2.0625
1.5312
1
2.5937
2.0625
1.0625
3.0625
2.0625
1
2.6875
1.625
0.625
2.625
1.625
1
3.625
2.625
2
1
4.625
3.625
3

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


20
20
24
24
24
24
24
24
END

16
18
12
14
16
18
20
22

30
30
36
36
36
36
36
36

2
1
5.625
5
4
3
2
1

30
30
36
36
36
36
36
36

2
1
5.625
5
4
3
2
1

Piping Component Table Green and Red CP Overflow Data


(P21B,P25B,P26B,P27B,P28B)
This table enables you to define overflow parameters for components to which table name formats
P21A, P25A, P26A, P27A, and P28A apply.
The table name formats for this table are:
For TNF=P21B MC_GS_Term(G)_Term(R)_B For TNF=P25B
MC_GS_Term(G)_Rat(G)_Term(R)_B For TNF=P26B
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_B For TNF=P27B
MC_GS_Term(G)_Term(R)_Rat(R)_B For TNF=P28B
MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_B

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
Par 6=ZZ
Par 7=ZZ
No_Inputs 2 No_Outputs 7
Units= NPD_IN, NPD_IN, IN, IN, IN, IN, IN, IN, IN
!
Nom Diam
Dimensional Parameters
! GCP
RCP
Par 1
Par 2
Par 3
Par 4
Par 5
Par 6
Par
7
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Plant Design System (PDS) Reference Data Manager (PD_Data)

255

Table Formats and Naming Conventions

Piping Component Table for Operators and Actuators (P31A)


This table enables you to define parameters for valve operators of piping valves whose operator
code list values (as defined in CL550 - Operator/Actuator Type) are equal to or less than 24.
The table name format that applies to this table is:
For TNF=P31A MC_Type(G)_Rat(G)_Op_A
where Type can have the following possible values:
Preparation

Type

2-199

BLT

300-399

MAL

400-599

FEM

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=P31Y
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
Par 6=ZZ
Par 7=ZZ
Par 8=ZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, IN, IN, IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Par 1
Par 2
Par 3
Par 4
Par 5
Par 6
Par 7
Par 8
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Example
Table_Data_Definition 'GAT_BLT_150_3_A'
! Description=Stem and handwheel operator
! Source=PDS Document 2630-33-OP
! TNF=P31A
By=GJH
Ckd By=RJW
Date=26-Feb-1987
! SN=OP3
Par 1=Y1
Par 2=Y2

256

Rev=0

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


No_Inputs 1 No_Outputs 2
Units= NPD_IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Par 1
Par 2
0.25
8.375
3.75
0.375 8.375
3.75
0.5
8.375
3.75
0.75
9.25
4.125
1
11.875
6
1.25
12.5
6
1.5
17.75
10
2
17.813
10
2.5
20.125
10
3
22.375
12
4
28.188
13.75
5
31.75
13.75
6
35.375
15.5
8
45
19.5
10
52.5
19.5
12
61.125
20
14
70.5
24
16
79.75
28
18
89
30
20
97.25
30
22
105
30
24
112.75
36
26
116
36
28
123.25
36
30
140
36
32
145
36
34
150
36
36
155.5
36
END

Piping Component Table for Operators and Actuators,


Overflow Data (P31B)
This table enables you to define overflow parameters for operators to which table name format
P31A applies.
The table name format that applies to this table is:
For TNF=P31B MC_Type(G)_Rat(G)_Op_B
where Type can have the following possible values:
Preparation

Type

2-199

BLT

300-399

MAL

400-599

FEM

Neutral File Format

Plant Design System (PDS) Reference Data Manager (PD_Data)

257

Table Formats and Naming Conventions


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=P31B
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
Par 1=ZZ
Par 2=ZZ
Par 3=ZZ
Par 4=ZZ
!
Par 5=ZZ
Par 6=ZZ
Par 7=ZZ
Par 8=ZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, IN, IN, IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Par 1
Par 2
Par 3
Par 4
Par 5
Par 6
Par 7
Par 8
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Piping Component Table for Empty Weight based on GCP


Data (P51,P52,P59)
This table enables you to define empty weights for components to which table name formats P51,
P52, and P59 apply.
The table name formats for this table are:
For TNF=P51
MC_GS_Term(G)_Sc/Th(G)_WC
For TNF=P52
MC_GS_Term(G)_Rat(G)_Sc/Th(G)_WC
For TNF=P59
Cmdty Code
With version 5.0, the Physical Data Library Manager will respect the use of a dash (-) in a table
name. This allows you to include a dash in the commodity code for a piping commodity valve,
where the commodity code is used to form the name of the dimension table.

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 1 No_Outputs 1
Units= NPD_IN, LB

258

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


! GCP
! Diam
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
WWWWW
END

Weight
Empty
ZZZZZZZ
ZZZZZZZ
ZZZZZZZ
ZZZZZZZ
ZZZZZZZ
ZZZZZZZ
ZZZZZZZ

Examples
Table_Data_Definition 'VAABAHCCAA'
! Description= CL150 gate valve raised face flanged ends weight
! Source= CRANE catalog for figure 47XU
! TNF=P59
By=GJH
Ckd By=RJW
Rev=0
Date=29-May-1987
No_Inputs 1 No_Outputs 1
Units= NPD_IN, LB
! GCP
Weight
! Diam
Empty
2
46
2.5
70
3
76
4
110
5
155
6
175
8
310
10
455
12
650
14
860
16
1120
18
1400
20
2125
24
3120
30
4250
END
Table_Data_Definition 'E90LR_39_300_S$STD_52'
! Description= 90 deg long radius elbow beveled ends
! Source= Taylor Forge Cat. 722
! TNF=P51
By=GJH
Ckd By=JPF
Rev=0
Date=24-Apr-1986
No_Inputs 1 No_Outputs 1
Units= NPD_IN, LB
! GCP
Weight
! Diam
Empty
0.5
0.17
0.75
0.17
1
0.34
1.25
0.58
1.5
0.84

Plant Design System (PDS) Reference Data Manager (PD_Data)

259

Table Formats and Naming Conventions


2
2.5
3
3.5
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
END

1.5
3
4.7
6.6
8.9
15
24
47
83
123
158
207
263
323
392
468
550
625
733
825
1061
1442
-

Piping Component Table For Empty Weight of Valves (P60A)


This table enables you to define empty weights of piping valves, weights and centers of gravity of
valve operators, model codes of valves operators and dimensional data of piping valve operators
whose operator code list values (as defined in CL550, Operator/Actuator Type) exceed 24 and are
less than or equal to 40.
The table name format that applies to this table is:
For TNF=P60A Cmdty Code_WOPD_A

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW_WOPD_A'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=P60A
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, LB, LB, IN, IN, IN, DEG, IN, IN

260

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


! GCP
! Diam
Y5
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
WWWWW
ZZZZZZZ
END

Weight
Vlv Emp

Weight
Oper

Oper
Code

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ ZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

ZZZZZZZ

Y1

Dimensional Parameters
Y2
Y3
Y4

Example
Table_Data_Definition 'VAABAHCCGR_WOPD_A'
! Description=Crane 47 gate valve with gear operator 3X-N for 14",
! 4X-N for 16, 18 & 20", & 6X-N for 24" valve.
! Par "Y4" includes a 8" mounting adaptor.
! Source=CRANE catalog for Converto-Gear valve operators
! TNF=P60A
By=GJH
Ckd By=DCG
Rev=1
Date=01-Dec-1987
! SN=VARIES
No_Inputs 1 No_Outputs 8
Units= NPD_IN, LB, LB, INT, IN, IN, DEG, IN, IN
! GCP
Weight
Weight Oper
Dimensional Parameters
! Diam
Vlv Emp Oper
Code
Y1
Y2
Y3
Y4
Y5
14
860
75
331
57.625
2.375
0
61.1875
8.75
16
1120
109
331
62
3.625
0
65.9688
10.625
18
1400
126
331
69.8125 4.25
0
73.7188
10.625
20
2125
150
331
80.375
5.5
0
84.2188
10.625
24
3120
248
331
92.75
4.625
0
99.375
15.25
END

Piping Component Table For Empty Weight of Valves,


Overflow Data (P60B)
This table enables you to define overflow parameters for
operators/actuators to which table name format P60A applies.
The table name format that applies to this table is:
For TNF=P60B Cmdty Code_WOPD_B

Plant Design System (PDS) Reference Data Manager (PD_Data)

261

Table Formats and Naming Conventions


Neutral File Format
Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW_WOPD_B'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=P60B
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
! SN=ZZZZZZ
No_Inputs 1 No_Outputs 8
Units= NPD_IN, IN, IN, IN, IN, IN, IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
WWWWW ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ ZZZZZZZ
ZZZZZZZ
END

Example
Table_Data_Definition 'VAABAHCCGR_WOPD_B'
! Description=Crane 47 gate valve with gear operator 3X-N for 14",
! 4X-N for 16, 18 & 20", & 6X-N for 24" valve.
! Source=CRANE catalog for Converto-Gear valve operators
! TNF=P60B
By=GJH
Ckd By=DCG
Rev=0
Date=22-May-1987
! SN=VARIES
No_Inputs 1 No_Outputs 7
Units= NPD_IN, IN, IN, IN, IN, IN, IN, IN
! GCP
Dimensional Parameters
! Diam
Y6
Y7
Y8
Y9
Y10
Y11
Y12
14
3.375
6.6875 12.375
20
0
16
3.625
7.2188 15.25
20
0
18
3.625
7.2188 15.25
24
0
20
3.625
7.2188 15.25
30
0
24
5.375
11.375 18.5
30
0
END

262

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions

Piping Component Table for Empty Weight based on GCP


and RCP Data (P61,P62,P63,P64,P65)
This table enables you to define empty weights for components to which table name formats P61,
P62, P63, P64, and P65 apply:
The table name formats for this table are:
For TNF=P61 MC_GS_Term(G)_Rat(G)_Term(R)_Rat/Sc/Th(R)_WC
For TNF=P62 MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_Sc/Th(R)_WC
For TNF=P63 MC_GS_Term(G)_Sc/Th(G)_Term(R)_Sc/Th(R)_WC
For TNF=P64 MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat(R)_WC
For TNF=P65 MC_GS_Term(G)_Sc/Th(G)_Term(R)_Rat/Sc/Th(R)_WC

Neutral File Format


Table_Data_Definition
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW'
! Description=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! Source=
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
! TNF=YYYY
By=ZZZ
Ckd By=ZZZ
Rev=ZZ
Date=ZZ-ZZZ-ZZZZ
No_Inputs 2 No_Outputs 1
Units= NPD_IN, NPD_IN, LB
!
Nom Diam
Weight
! GCP
RCP
Empty
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
WWWWW WWWWW ZZZZZZZ
END

Example
Table_Data_Definition 'REDC_39_300_S$60_300_S$40_52'
! Description= Concentric reducer beveled ends weight.
! Source= TAYLOR FORGE Cat. 722, weights for schedule 60 fitting
! TNF=P63
By=GJH
Ckd By=JPF
Rev=0
Date=15-Aug-1986
No_Inputs 2 No_Outputs 1
Units= NPD_IN, NPD_IN, LB
!
Nom Diam
Weight
! GCP
RCP
Empty
14
12
92
16
14
125
16
12
125
18
14
173
18
12
173

Plant Design System (PDS) Reference Data Manager (PD_Data)

263

Table Formats and Naming Conventions


20
20
20
22
22
22
24
24
END

18
14
12
20
18
14
20
18

278
278
278
397
397

Piping Component Tables for Specialty Components


Six dimension tables are used for each combination of piping specialty generic name (AABBCC
code) and piping specialty model code. The AABBCC code is defined in the PDS Sort Code
attribute of the Piping Specialty Specification Data of the Material Reference Database.
The tables used to to define the physical data for piping specialty components have the same
format as those used to define instrument components. The table names are of the format:
EQBODY_SPECIFIC_<PSC>_<MC>_A, _B, _C - Specialty Body Data
EQOPER_SPECIFIC_<PSC>_<MC>_A, _B, _C - Specialty Operator/Actuator Data
Refer to Instrument Component Tables (on page 264) for more information on these tables.

Instrument Component Tables


Six dimension tables are used for each combination of instrument name (pds_sort_code) and
instrument model code. Multiple tables are required since tables with one input are limited to
nine outputs. The instrument pds_sort_code is defined in the Instrument Component Specification
Data of the Material Reference Database (Table 204 attribute 18). (For the delivered examples,
the pds_sort_code is the Instrument AABBCC code as defined in the PDS Component Data
Reference Guide.)
Input to these tables is defined in the physical_data_id attribute of the Instrument Component
Specification Data (Table 204 attribute 17). The entries in the tables must agree with the entries
in the Instrument Component Specification Data of the Material Reference Database.
Each table is limited to approximately 60,000 bytes or 750 lines.
When the tables are created in the Physical Data Library, you should define the values for the
physical units for length, surface area, and weight to match the seed data defined for the project.

See Also
Instrument Body Data (see "Instrument Body (I80 and P80)" on page 264)
Instrument Operator/Actuator Data (see "Instrument Operator (I81 and P81)" on page 266)

Instrument Body (I80 and P80)


Three tables define the instrument body physical and geometric data for each combination of
instrument pds_sort_code and the model code in the Instrument Component Specification Data of
the Material Reference Database.
The default prefix for these table names is Inbody. You can specify a user-defined prefix up to 6
characters for the table names. If you use a user-defined prefix, you must revise the appropriate
Piping Eden modules for the instruments.
The prefix is followed by either Specific or Typical, the instrument pds_sort_code, the model code,
and a letter indicating the table (A-C).

264

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


Inbody_Specific_PSC_MC_A

The input field is the physical_data_id for the instrument.


The first four output fields are the surface area, the dry weight, the water weight, and the number
of connect points for the instrument.
The remaining output fields are the dimensional parameters P2 through P6, as prescribed in the
PDS Piping Component Data Reference Guide.

Inbody_Specific_PSC_MC_B

The output fields are the dimensional parameters P7 through P15, as prescribed in the PDS
Piping Component Data Reference Guide.

Plant Design System (PDS) Reference Data Manager (PD_Data)

265

Table Formats and Naming Conventions


Inbody_Specific_PSC_MC_C

The output fields are the dimensional parameters P16 through P24, as prescribed in the PDS
Piping Component Data Reference Guide.

Instrument Operator (I81 and P81)


Three tables are required for the instrument operator/actuator geometric data for each
combination of instrument pds_sort_code and model code in the Instrument Component
Specification Data of the Material Reference Database.
The default prefix for these table names is Inoper. You can specify a user-defined prefix, up to 6
characters, for the table names. If you specify a user-defined prefix, you must revise the
appropriate Piping Eden modules for these instrument operators.
The prefix is followed by either Specific or Typical, the instrument pds_sort_code, the model code,
and a letter indicating the table (A - C).

Inoper_Specific_PSC_MC_A

The first two output fields for this table are the operator weight and the operator type. The
operator type must be loaded in the modifier attribute of the Instrument Component Specification
Data of the Material Reference Database. The operator type is the number (such as 411)
representing the operator and not the symbol name (such as OP_411).

266

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Formats and Naming Conventions


The remaining output fields are dimensional parameters Y2 through Y8, as prescribed in the PDS
Piping Component Data Reference Guide. For some operators, the first three dimensional
parameters, Y2 through Y4, define the center of gravity for the operator in terms of offsets from the
instrument center.

Inoper_Specific_PSC_MC_B

The output fields are the dimensional parameters Y9 through Y17, as prescribed in the PDS
Piping Component Data Reference Guide.

Inoper_Specific_PSC_MC_C

The output fields are the dimensional parameters Y18 through Y24, as prescribed in the PDS
Piping Component Data Reference Guide.

Plant Design System (PDS) Reference Data Manager (PD_Data)

267

SECTION 10

Material Description Data


The PDS 3D modules use the Material Description Library and the material data in the Material
Reference Database to provide material descriptions for commodity items and specialty items.
This data is accessed for:
Material Take-off (MTO) reporting from the Design Database.
Other miscellaneous reporting.
Interfaces to a material control system.
Stress analysis.
Isometric drawing extraction.
The alphanumeric commodity data is made up of four major parts:
Material Data in the Material Reference Database (on page 272) - These database tables (211
and 212) contain commodity definitions which enable you to further classify the commodity
items defined in the Piping Job Specification. This database information tends to be
customer-specific.
Short Material Description Library (on page 273) - This library contains the short
bill-of-material (BOM) descriptions for all piping commodity items and the BOM description
addenda for taps.
Long Material Description Library (on page 279) - This library contains the long bill-of-material
descriptions for all piping commodity items. The long BOM description is only used for
requisitions.
Specialty Material Description Library (on page 281) - This library contains the bill-of-material
descriptions for engineered items, in-line instruments, and pipe supports.
The material description data in these files is used for reporting and material control and is not
required for the interactive placement of symbols in the model. This data is only accessed during
a batch (non-interactive) process.

See Also
Material Description Library Manager (on page 282)

Plant Design System (PDS) Reference Data Manager (PD_Data)

269

Material Description Data


Commodity Code
The system uses the commodity code as an index to access the descriptions in the material
description libraries. You can use the commodity code defined in the Piping Commodity
Specification Data table (Table 202 attribute 18) or a user-defined commodity code defined in the
Size-Dependent Material Data table (Table 211 attribute 7).

The source of the commodity code and other processing options for reporting are defined for a
model with the Material Takeoff Options form of the Project Data Manager.
The commodity code represents that set of parameters that completely describe a commodity
item, exclusive of nominal piping diameter and thickness. The character length for the
commodity code is determined from the character length of the commodity code in the Size
Dependent Data table of the database, or from the character length of the commodity code in the
Piping Commodity Data table of the database, depending on which is being used to access the
material descriptions.
The delivered commodity codes use a 10 character code to fully identify the item. The first letter
of the commodity code identifies the basic type of component, such as a valve or flange. The
remaining characters provide a detailed description of the component. The first character
designations are:

270

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


B

Flanged and Misc. Fittings

Socket End Fittings

Fire and Safety Components

Tubing Fittings

Steam Specialties

Socketwelded Fittings

Flanges

Threaded Fittings

Flanged Specialties

Underground Fittings

Strainers

Valves

M Misc. Wetted Components

W Welded Fittings

Misc. Non-Wetted Components

Gaskets

Tubing and Hose

Bolting

Pipe

Examples
1 2
P A
P
AD
AA
BC
AAE
V A
V
A
A
B
A
H
CC
AA

3
D
A
-

4 5 6 7 8 9 0
A A B C A A E
Pipe
Pipe, Plain Ends
Seamless
X-Strong (s-xs)
ASTM A106 Gr. B
B A H C C A A
Valve
Gate Valve
CL150
Raised Face Flanged Ends
Carbon Steel
Trim 8
Crane 47
Blank

Refer to the PDS Piping Component Data Reference Guide for a complete listing of the delivered
commodity codes.
You can use the delivered commodity codes or create your own naming scheme. Regardless of
the scheme used, all the codes must be unique and there must be an exact match between the
commodity code specified for an item in the Material Reference Database and commodity codes
used to define the material descriptions in the Material Descriptions Library.

Tap Commodity Codes


The delivered tap codes use a 10 character code to full identify the tap's material description
addendum. The basic format of the tap commodity code is:
A BBB CCC DDD
where
A

E if English.

BBB

the nominal diameter value of the tap such as $50, $75, or 001. The use of leading
and trailing zeroes is specific to this table naming convention. ($ represents a
decimal point.)

Plant Design System (PDS) Reference Data Manager (PD_Data)

271

Material Description Data


CCC

End preparation value as defined in code list set 330.

DDD

user-defined value.

Example
1 2 3 4 5 6 7 8 9 0
E $ 5 0 4 2 1 0 6 4
E
- English
$50 - NPD = 0.5 inches
421 - SWE - socketwelded end
064 - unique number

Tri-Clover Commodity Code Logic


The Tri-Clover commodity codes are based on Tri-Clover part numbers, but have been modified
so that they are less than 18 characters.

Example
Tri-Clover part number:
BS14AM-4"-316L-PL
BS14AM = Part Description
4"
= Size
316L
= Material Grade
PL
= Surface Finish Description
Tri-Clover commodity code:
BS14AM316LPL
In the Tri-Clover commodity code, the dashes ("-") and size are removed so that the commodity
code is less than 18 characters. The commodity code description lists the full part number.

Material Data in the Material Reference Database


The Material Reference Database contains two database tables which contain Material Data.
Piping Commodity Size-Dependent Material Data (211)
The Size-Dependent Data table contains the data for a specific commodity item that is
dependent on the commodity code, nominal piping diameter, and schedule/thickness. It is
used for miscellaneous batch reporting, such as construction cost reports and requisition
orders, and interfaces to material control, stress analysis, and isometric drawing extraction.
Piping Commodity Implied Material Data (212)
The Implied Material Data table contains the implied material data for a specific commodity
item that is dependent on both the Piping Commodity Library code and nominal piping
diameter range. This data is used strictly for generating implied material for MTO reporting
and material control. It is not used for welds, bolts, nuts, or gaskets, but is reserved for other
types of implied material, such as caps or stubs, for a specific commodity item. It is also used
for reporting the implied components of a commodity item (such as cap screws).
Refer to Material Reference Database Structure (on page 41) for information on the structure of
these database tables. Also, refer to the description of the Piping Job Specification Manager (on
page 107) for information on loading material data into these database tables via neutral files.

272

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data

Short Material Description Library


This library contains the short bill of materials description for all piping commodity items and the
description addenda for taps. The short BOM description is used for MTO reporting and for
reporting from the Piping Job Specification. This parameter is required during the creation of the
Piping Job Specification. Nominal piping diameter is not included in this description.
The short material descriptions are delivered in the
\win32app\ingr\rdusrdb\us_shbom.l object library.
The short material descriptions can be up to 240 characters in length.

Neutral Files
You can use neutral files to insert data into the Short Material Description Library or replace
existing data. The neutral files for the delivered material descriptions are contained in the text
library. You can use the neutral files in the following files:
The Short Material Description Library is created from two neutral files. (These can be created
with a text editor such as Notepad.)
A neutral file containing the short material descriptions for commodity items. The neutral file
contains unique Commodity Codes followed by at least one space and a description enclosed
in single quotes. It also contains the chain wheel descriptions and implied material
descriptions associated with a commodity item.
The commodity code identifies the Piping Commodity Library code or customer's commodity
code. The character length for this code is determined from the character length of the
commodity code in the Size Dependent Data table of the database, or from the character
length of the commodity library code in the Piping Commodity Data table of the database,
depending on which is being used to access the material descriptions.
For chain wheels, the commodity code has the format CHAIN_xx, where xx represents the
chain wheel number (for example, CHAIN_12). The chain wheel number is defined in the
component and instrument analysis entities of the TDB.
A neutral file containing the material description addenda for taps. This file contains the tap
code and the text for the tap description. The tap code identifies the unique identification of a
tap.
The commodity code of an item must be entered in capital letters when creating and
loading material description data. This applies to short, long, and specialty material description
data and their libraries.
The following conventions are used to identify different types of information in the material
descriptions:
^

All information to the left of the carat (^) is used in MTO reporting and isometric extraction,
but is excluded from Spec reporting.

||

Information appearing in |Pipes| indicates information for Spec descriptions only. This
information is excluded from the descriptions for MTO reporting and isometric extraction.

[]

Information appearing in [brackets] indicates a label type from the Label Description
Library. The system uses the label format to determine the information to be included in
the material description for MTO reporting and isometric extraction. The label information
is never used in Spec reporting.
The following label types are provided in the product delivery:

Plant Design System (PDS) Reference Data Manager (PD_Data)

273

Material Description Data


Label No

Data in Label

Source of Data

400

Comp cmdty code

Component

401

Piping sch/thk 1

Pipe

402

Tag no

Component

403

Component sch/thk 1

Component

406

Component sch/thk 1 b

Component

407

Component sch/thk 2

Component

409

Component sch/thk 2 b

Component

412

Component sch/thk 1 x 2

Component

414

Component sch/thk 1 x 2 b Component

416

Component sch/thk 1 x 3

417

Component sch/thk 1 x 3 b Component

421

Bonnet length

Component

422

Piping chain length

Component

423

Reinforcing weld size

Component

424

Instr chain length

Component

425

RPAD width x thick

Component

426

Comp NPD 1

Component

427

Monitor elev length

Component

428

Hydrant cover

Component

429

Blank/spacer thk

Component

Component

Data Retrieval
The system uses the commodity code to retrieve the short material descriptions from the Material
Description Library.
Commodity Material Descriptions
!
DEFINE SHORT DESCRIPTIONS
! Date/Time: Thu Apr 23 14:16:58 1992
! Processed Library c:
ewpipe\refdata\us_shbom.l
!Cmdty Code
====================================Description========================
================
CHAIN_1003
'Chainwheel operator each with [422] of total chain
length for [426] NPD valve with commodity code [400]'
CHAIN_1005
'Chainwheel operator each with [422] of total chain
length for [426] NPD valve with commodity code [400]'
CHAIN_1251
'Chainwheel operator each with [424] of total chain
length for valve with tag no [402]'
DAABAXAABE
'Monitor, CL150 FFFE, ^station type, 4" CL150 in-let by
2.5" NHT stainless steel outlet

274

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


w/stainless steel stem lock knobs with 0.75" coupling
in base, w/shapertip nozzle, Stang BB0309-21'
DAABAXAABF
'Monitor, CL150 FFFE, ^station type 4" CL150 in-let by
2.5" NHT stainless steel
outlet w/stainless steel stem lock knobs with 0.75"
coupling in base, w/fog nozzle,
Stang BB0309-21'
DACBAXABBC
'Monitor, CL150 FFFE, ^elevated type, free standing, 4"
CL150 in-let by 2.5" NHT
stainless steel outlet, [427], w/drain coupling,
w/shapertip nozzle and two reaction supports,
Stang BB2999-'
DACBAXABBD
'Monitor, CL300 FFFE, ^elevated type, supported, 6"
CL300 in-let by 2.5" NHT stainless
steel outlet, [427], w/drain coupling, w/shapertip
nozzle, Stang BB3561'
DBAAAXBAAB
'Fire hydrant, CL125 FFFE, ^5" size, counterclockwise
open, 4.5" steamer nozzle,
two 2.5" hose nozzles equipped w/caps and chains, [428],
American Darling B-50-B'
DCBGDXEADA
'Hose rack, 300#, FTE, ^w/valve, wall mount, rt hand
w/100 ft hose & fog nozzle Powhatan 30-333'
DDAXCJDAAA
'Spray sprinkler, MTE, filled cone w/rupture disc, 304,
Grinnell, Mulsifyre Projector S-1'
FAAAAAWAAA
'Flange, CL150, FFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
[409]|bore to match|'
FAAAAAWWAA
'Flange, CL150, FFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
cement lined, [409]|bore to match|'
FAAABADIIA
'Flange, CL150, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, S-80S bore'
FAAABADIIF
'Flange, CL150, RFFE/BE, ^ASTM-A182-F316, ANSI-B16.5,
WN, S-80S bore'
FAAABADNPF
'Flange, CL150, RFFE/BE, ^ASTM-B166-600, ANSI-B16.5,
WN, S-80S bore'
FAAABAOAAA
'Flange, CL150, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
S-160 bore'
FAAABAOABB
'Flange, CL150, RFFE/BE, ^ASTM-A350-LF2, ANSI-B16.5,
WN, S-160 bore'
FAAABAOFFH
'Flange, CL150, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, S-160 bore'
FAAABAWAAA
'Flange, CL150, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
[409]|bore to match|'
FAAABAWABB
'Flange, CL150, RFFE/BE, ^ASTM-A350-LF2, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABAWFFH
'Flange, CL150, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABAWFFL
'Flange, CL150, RFFE/BE, ^ASTM-A182-F9, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABAWGFD
'Flange, CL150, RFFE/BE, ^ASME-SA182-F11, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABAWIIA
'Flange, CL150, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABAWIIF
'Flange, CL150, RFFE/BE, ^ASTM-A182-F316, ANSI-B16.5,
WN, [409]|bore to match|'

Plant Design System (PDS) Reference Data Manager (PD_Data)

275

Material Description Data


FAAABAWNPF
'Flange, CL150, RFFE/BE, ^ASTM-B166-600, ANSI-B16.5,
WN, [409]|bore to match|'
FAAABBDAAA
'Flange, CL150, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
S-XXS bore'
FAAADAOAAA
'Flange, CL150, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
125 Ra finish, S-160 bore'
FAAADAOFFC
'Flange, CL150, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, 125 Ra finish, S-160 bore'
FAAADAWAAA
'Flange, CL150, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
125 Ra finish, [409]|bore to match|'
FAAADAWFFC
'Flange, CL150, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, 125 Ra finish, [409]|bore to match|'
FAAADBDFFC
'Flange, CL150, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, 125 Ra finish, S-XXS bore'
FAABBADIIA
'Flange, CL300, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, S-80S bore'
FAABBADIIB
'Flange, CL300, RFFE/BE, ^ASTM-A182-F304L, ANSI-B16.5,
WN, S-80S bore'
FAABBADIIF
'Flange, CL300, RFFE/BE, ^ASTM-A182-F316, ANSI-B16.5,
WN, S-80S bore'
FAABBAOAAA
'Flange, CL300, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
S-160 bore'
FAABBAOABB
'Flange, CL300, RFFE/BE, ^ASTM-A350-LF2, ANSI-B16.5,
WN, S-160 bore'
FAABBAOFFC
'Flange, CL300, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, S-160 bore'
FAABBAOFFH
'Flange, CL300, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, S-160 bore'
FAABBAWAAA
'Flange, CL300, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
[409]|bore to match|'
FAABBAWABB
'Flange, CL300, RFFE/BE, ^ASTM-A350-LF2, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWFFC
'Flange, CL300, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWFFH
'Flange, CL300, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWFFL
'Flange, CL300, RFFE/BE, ^ASTM-A182-F9, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWIIA
'Flange, CL300, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWIIB
'Flange, CL300, RFFE/BE, ^ASTM-A182-F304L, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWIIF
'Flange, CL300, RFFE/BE, ^ASTM-A182-F316, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBAWNPF
'Flange, CL300, RFFE/BE, ^ASTM-B166-600, ANSI-B16.5,
WN, [409]|bore to match|'
FAABBBDAAA
'Flange, CL300, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
S-XXS bore'
FAABDADIIJ
'Flange, CL300, RFFE/BE, ^ASTM-A182-F321, ANSI-B16.5,
WN, 125 Ra finish, S-80S bore'
FAABDAOAAA
'Flange, CL300, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
125 Ra finish, S-160 bore'
FAABDAOFFC
'Flange, CL300, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, 125 Ra finish, S-160 bore'

276

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


FAABDAWAAA
'Flange, CL300, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
125 Ra finish, [409]|bore to match|'
FAABDAWFFC
'Flange, CL300, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, 125 Ra finish, [409]|bore to match|'
FAABDAWFFH
'Flange, CL300, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, 125 Ra finish, [409]|bore to match|'
FAABDAWIIJ
'Flange, CL300, RFFE/BE, ^ASTM-A182-F321, ANSI-B16.5,
WN, 125 Ra finish, [409]|bore to match|'
FAADBADIIA
'Flange, CL600, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, S-80S bore'
FAADBADIIF
'Flange, CL600, RFFE/BE, ^ASTM-A182-F316, ANSI-B16.5,
WN, S-80S bore'
FAADBAOAAA
'Flange, CL600, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
S-160 bore'
FAADBAOABE
'Flange, CL600, RFFE/BE, ^ASME-SA105, ANSI-B16.5, WN,
S-160 bore'
FAADBAWAAA
'Flange, CL600, RFFE/BE, ^ASTM-A105, ANSI-B16.5, WN,
[409]|bore to match|'
FAADBAWABE
'Flange, CL600, RFFE/BE, ^ASME-SA105, ANSI-B16.5, WN,
[409]|bore to match|'
FAADBAWFFC
'Flange, CL600, RFFE/BE, ^ASTM-A182-F11, ANSI-B16.5,
WN, [409]|bore to match|'
FAADBAWFFH
'Flange, CL600, RFFE/BE, ^ASTM-A182-F5, ANSI-B16.5,
WN, [409]|bore to match|'
FAADBAWFFL
'Flange, CL600, RFFE/BE, ^ASTM-A182-F9, ANSI-B16.5,
WN, [409]|bore to match|'
FAADBAWIIA
'Flange, CL600, RFFE/BE, ^ASTM-A182-F304, ANSI-B16.5,
WN, [409]|bore to match|'
Tap Material Descriptions
!
DEFINE SHORT DESCRIPTIONS
! Date/Time: Thu Apr 23 12:09:23 1992
! Processed Library c:
ewpipe\refdata\us_shbom.l
!Cmdty Code
====================================Description========================
========
E$12591XXX
'0.125" diam hole'
E$25591XXX
'0.25" diam hole'
E$37591XXX
'0.375" diam hole'
E$50021018
'0.5" NPD, CL150 RFFE tap'
E$50021028
'0.5" NPD, CL300 RFFE tap'
E$50021036
'0.5" NPD, CL600 RFFE tap'
E$50401093
'0.5" NPD, Sch 80 SE tap'
E$50421064
'0.5" NPD, CL3000 SWE tap'
E$50421072
'0.5" NPD, CL6000 SWE tap'
E$50421076
'0.5" NPD, CL9000 SWE tap'
E$50441056
'0.5" NPD, CL2000 FTE tap'
E$50441064
'0.5" NPD, CL3000 FTE tap'
E$50441072
'0.5" NPD, CL6000 FTE tap'
E$50591XXX
'0.5" diam hole'
E$75021018
'0.75" NPD, CL150 RFFE tap'
E$75021028
'0.75" NPD, CL300 RFFE tap'

Plant Design System (PDS) Reference Data Manager (PD_Data)

277

Material Description Data


E$75021036
E$75401093
E$75421064
E$75421072
E$75421076
E$75441056
E$75441064
E$75441072
E$75591XXX
E001021018
E001021028
E001021036
E001401093
E001421064
E001421072
E001421076
E001441056
E001441064
E001441072
E001591XXX
E002021018
E002021028
E002021036
E002401093
E002421064
E002421072
E002421076
E002441056
E002441064
E002441072
E002591XXX
E003021018
E003021028
E003021036
E003401093
E003421064
E003441056
E003441064
E003441072
E003591XXX
E004021018
E004021028
E004021036
E004401093
E004421064
E004441056
E004441064
E004441072
E004591XXX

278

'0.75" NPD, CL600 RFFE tap'


'0.75" NPD, Sch 80 SE tap'
'0.75" NPD, CL3000 SWE tap'
'0.75" NPD, CL6000 SWE tap'
'0.75" NPD, CL9000 SWE tap'
'0.75" NPD, CL2000 FTE tap'
'0.75" NPD, CL3000 FTE tap'
'0.75" NPD, CL6000 FTE tap'
'0.75" diam hole'
'1" NPD, CL150 RFFE tap'
'1" NPD, CL300 RFFE tap'
'1" NPD, CL600 RFFE tap'
'1" NPD, Sch 80 SE tap'
'1" NPD, CL3000 SWE tap'
'1" NPD, CL6000 SWE tap'
'1" NPD, CL9000 SWE tap'
'1" NPD, CL2000 FTE tap'
'1" NPD, CL3000 FTE tap'
'1" NPD, CL6000 FTE tap'
'1" diam hole'
'2" NPD, CL150 RFFE tap'
'2" NPD, CL300 RFFE tap'
'2" NPD, CL600 RFFE tap'
'2" NPD, Sch 80 SE tap'
'2" NPD, CL3000 SWE tap'
'2" NPD, CL6000 SWE tap'
'2" NPD, CL9000 SWE tap'
'2" NPD, CL2000 FTE tap'
'2" NPD, CL3000 FTE tap'
'2" NPD, CL6000 FTE tap'
'2" diam hole'
'3" NPD, CL150 RFFE tap'
'3" NPD, CL300 RFFE tap'
'3" NPD, CL600 RFFE tap'
'3" NPD, Sch 80 SE tap'
'3" NPD, CL3000 SWE tap'
'3" NPD, CL2000 FTE tap'
'3" NPD, CL3000 FTE tap'
'3" NPD, CL6000 FTE tap'
'3" diam hole'
'4" NPD, CL150 RFFE tap'
'4" NPD, CL300 RFFE tap'
'4" NPD, CL600 RFFE tap'
'4" NPD, Sch 80 SE tap'
'4" NPD, CL3000 SWE tap'
'4" NPD, CL2000 FTE tap'
'4" NPD, CL3000 FTE tap'
'4" NPD, CL6000 FTE tap'
'4" diam hole'

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data

Long Material Description Library


This library contains the long bill of materials description for all piping commodity items. The long
bill of materials description is only used for requisitions. It is usually a very long description such as
a paragraph. Nominal piping diameter is not included in the description.
This data is used strictly for MTO reporting and material control.
The long material descriptions are delivered in the file \win32app\ingr\rdusrdb\us_lgbom.l.
The long material descriptions can be up to 500 characters in length.

Neutral Files
The Long Material Description Library is created through a neutral file which contains the long
material descriptions for commodity items. The neutral file contains unique commodity codes
followed by at least one space and a description enclosed in single quotes.
You can use neutral files to insert data into the Long Material Description Library or replace
existing data.
The commodity code identifies the Piping Commodity Library code or customer's commodity
code. The character length for this code is determined from the character length of the commodity
code in the Size Dependent Data database table, or from the character length of the commodity
library code in the Piping Commodity Data table of the PJS database, depending on which is being
used to access the material descriptions.
The long description can be up to 500 characters. Because this description may include label
numbers which are translated to text strings, the reported (compiled) length of the description can
be up to 600 characters.
Prior to the 5.0 release, there was a restriction that no more than 255 characters could be
specified per line in the neutral file. This required that long descriptions be continued on multiple
lines. With the 5.0 release, a neutral file for long material descriptions may contain up to 600
characters per line.
The commodity code of an item must be entered in capital letters when creating and
loading material description data. This applies to short, long, and specialty material description
data and their libraries.

Data Retrieval
The system uses the Piping Commodity Library code or commodity code to access the text for the
long description in the Long Material Description Library.
Listing for Long Material Descriptions
!
DEFINE LONG DESCRIPTIONS
! Date/Time: Fri Apr 24 10:48:13 1992
! Processed Library c:
ewpipe\refdata\us_lgbom.l
!Cmdty Code
====================================Description========================
================
DAABAXAABE
'Monitor, 750 GPM at 100 psig, CL150 flat face flange
end, station type, 4" CL150 in-let by 2.5" NHT stainless
steel outlet w/stainless steel stem lock knobs with
0.75" coupling in base, w/shapertip nozzle, Stang BB0309-21
or approved equal'

Plant Design System (PDS) Reference Data Manager (PD_Data)

279

Material Description Data


DAABAXAABF
'Monitor, 750 GPM at 100 psig, CL150 flat face flange
end, station type 4" CL150 in-let by 2.5" NHT stainless
steel outlet w/stainless steel stem lock knobs with
0.75" coupling in base, w/fog nozzle, Stang BB0309-21
or approved equal'
DACBAXABBC
'Monitor, 750 GPM at 100 psig, CL150 flat face flange
end, elevated type, free standing, 4" CL150 in-let by
2.5" NHT stainless steel outlet, w/drain coupling,
w/shapertip nozzle and two reaction supports,
Stang BB2999-[427] high or approved equal'
DACBAXABBD
'Monitor, 750 GPM at 100 psig, CL300 flat face flange
end, elevated type, supported, 6" CL300 in-let by 2.5"
NHT stainless steel outlet, w/drain coupling,
w/shapertip nozzle, Stang BB3561-[427] high or approved equal'
DBAAAXBAAB
'Fire hydrant, CL125 flat face flange end, 5" size,
regular rating, ductile iron barrel, bronze trim,
bituminous paint below grade, red epoxy paint above
grade, counterclockwise open, 4.5" steamer nozzle, two 2.5"
hose nozzles equipped w/caps and chains, [428],
American Darling B-50-B or approved equal'
DCBGDXEADA
'Hose rack w/bronze angle valve, 300#, female threaded
end, wall mount, right hand w/100 ft synthetic single
jacketed hose, rack nipple & fog nozzle, Powhatan 30-333
or approved equal'
DDAXCJDAAA
'Spray sprinkler, male threaded end, filled cone
w/rupture disc, .313" orifice, Type 304 stainless steel,
Grinnell Fire Protection, Mulsifyre Projector S-1 50-12
or approved equal'
FAAAAAWAAA
'Flange, weld neck, flat face flanged end, ANSI-B16.5
CL150, ASTM-A105, [409]'
FAAAAAWWAA
'Flange, weld neck, flat face flanged end, ANSI-B16.5
CL150, ASTM-A105, cement lined, [409]'
FAAABADIIA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F304, Sch 80S bore'
FAAABADIIF
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F316, Sch 80S bore'
FAAABADNPF
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-B166 Gr.600 UNS N06600, hot finish, Sch 80S bore'
FAAABAOAAA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A105, Sch 160 bore'
FAAABAOABB
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A350 Gr.LF2, Sch 160 bore'
FAAABAOFFH
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F5, Sch 160 bore'
FAAABAWAAA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A105, [409]'
FAAABAWABB
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A350 Gr.LF2, [409]'
FAAABAWFFH
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F5, [409]'
FAAABAWFFL
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F9, [409]'
FAAABAWGFD
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASME-SA182 Gr.F11, [409]'

280

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


FAAABAWIIA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F304, [409]'
FAAABAWIIF
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A182 Gr.F316, [409]'
FAAABAWNPF
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-B166 Gr.600 UNS N06600, hot finish, [409]'
FAAABBDAAA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL150, ASTM-A105, XX-strong bore'
FAAADAOAAA
'Flange, weld neck, raised face flanged end, 125 Ra
finish, ANSI-B16.5 CL150, ASTM-A105, Sch 160 bore'
FAAADAOFFC
'Flange, weld neck, raised face flanged end, 125 Ra
finish, ANSI-B16.5 CL150, ASTM-A182 Gr.F11, Sch 160 bore'
FAAADAWAAA
'Flange, weld neck, raised face flanged end, 125 Ra
finish, ANSI-B16.5 CL150, ASTM-A105, [409]'
FAAADAWFFC
'Flange, weld neck, raised face flanged end, 125 Ra
finish, ANSI-B16.5 CL150, ASTM-A182 Gr.F11, [409]'
FAAADBDFFC
'Flange, weld neck, raised face flanged end, 125 Ra
finish, ANSI-B16.5 CL150, ASTM-A182 Gr.F11, XX-strong bore'
FAABBADIIA
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL300, ASTM-A182 Gr.F304, Sch 80S bore'
FAABBADIIB
'Flange, weld neck, raised face flanged end, ANSI-B16.5
CL300, ASTM-A182 Gr.F304L, Sch 80S bore'

Specialty Material Description Library


This Library contains the material descriptions for any engineered items or in-line instruments
which are reported by MTO or material control. These material descriptions are job-specific and
are accessed by the specialty item's tag number.
This data is used strictly for MTO reporting and material control. The specialty material
descriptions can be up to 240 characters in length.

Neutral Files
Three neutral files are used to insert data into or replace data for the specialty material
descriptions.
Material descriptions for engineered items
(engineered item number = tag).
Material descriptions for instruments.
(instrument tag number = tag).
Material descriptions for pipe supports.
(commodity code = tag).
These files contain the specialty tag number and the text for the material description. The specialty
tag number is appended by a specialty type which is used to distinguish between engineered
items, in-line instruments, and pipe supports.
The commodity code of an item must be entered in capital letters when creating and
loading material description data. This applies to short, long, and specialty material description
data and their libraries.
The descriptions in Specialty Material Description Library tend to be customer-specific. The
following is a listing of sample neutral files for the specialty data.
!
DEFINE SPECIALTY DESCRIPTIONS
! Date/Time: Thu Apr 30 09:02:24 1992

Plant Design System (PDS) Reference Data Manager (PD_Data)

281

Material Description Data


! Processed Library c:
ewpipe\refdata\us_spbom.l
!Cmdty Code
====================================Description========================
======
38-VI-9
'RELIEF CONTROL VALVE.'
INSTR
'Instrument'
PSPECIALTY
'Piping specialty component'
PSUPPORT
'[970]'
!
DEFINE SPECIALTY DESCRIPTIONS
! Date/Time: Thu Apr 30 09:02:39 1992
! Processed Library c:
ewpipe\refdata\us_spbom.l
!Cmdty Code
====================================Description========================
======
SPECIAL_ENGR
'SPECIAL ANGLE OUTLET.'
SPECIAL_ENGR
8 'SPECIAL ANGLE OUTLET.'
SPECIAL_ENGR
@fffffe"ffff98O 'SPECIAL ANGLE OUTLET.'
!
DEFINE SPECIALTY DESCRIPTIONS
! Date/Time: Thu Apr 30 09:02:56 1992
! Processed Library c:
ewpipe\refdata\us_spbom.l
!Cmdty Code
====================================Description========================
======
SUPP1
'PIPE SUPPORT NUMBER 1.'
SUPP1
8 'PIPE SUPPORT NUMBER 1.'
SUPP1
@fffffe"ffff98O 'PIPE SUPPORT NUMBER 1.'
SUPP2
'PIPE SUPPORT NUMBER 2.'
SUPP2
8 'PIPE SUPPORT NUMBER 2.'
SUPP2
@fffffe"ffff98O 'PIPE SUPPORT NUMBER 2.'
SUPP3
'PIPE SUPPORT NUMBER 3.'
SUPP3
8 'PIPE SUPPORT NUMBER 3.'
SUPP3
@fffffe"ffff98O 'PIPE SUPPORT NUMBER 3.'

Data Retrieval
The system uses the specialty tag number and specialty type to access the text for the material
descriptions in the Specialty Material Description Library.

Material Description Library Manager


The Material Description Library Manager enables you to create and modify alphanumeric
commodity data. You can initialize libraries, create material description data, append new data to
existing material description data, revise (delete and replace) existing data, and delete existing
data.
You can use the copy and paste commands to copy existing library data from another project and
make the necessary revisions using the Material Description Library Manager.

Operating Sequence
1. Select Material Description Library Manager from the Reference Data Manager form.

282

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


The system displays the Material Description Library Manager form.

2. Select the option for the library to be modified.


Short Material Description Library
Long Material Description Library
Specialty Material Description Library
3. The data manipulation options for each of the libraries is similar. You can perform the
following activities for each of the libraries.

Plant Design System (PDS) Reference Data Manager (PD_Data)

283

Material Description Data

Create Library (on page 284) Creates a new (empty) Short Material Description Library,
Long Material Description Library, or Specialty Material Description Library.
Unapprove ==> Approve (see "Unapproved ==> Approved" on page 285) Copies data from
the unapproved library to the approved library.
Load/Revise Interactive (on page 285) Adds the contents of the neutral files to the
information currently in an existing Material Description Library or revises an existing table in
the library.
Load/Revise Batch (on page 286) Adds the contents of the neutral files to the information
currently in an existing Material Description Library or revises an existing table in the library.
Replace Interactive (on page 286) Deletes all entries in the respective Material Description
Library file and then loads new entries from a neutral file.
Replace Batch (on page 287) Deletes all entries in the respective Material Description
Library file and then loads new entries from a neutral file.
Report (see "Report Option" on page 288) Used to create a report file or a neutral file of the
contents of the material description library.

Create Library
This option is used to create a new Material Description Library. This option is disabled if the
library already exists.
1. Select Create Library from the Material Description Library Manager form.

284

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


The system displays the approved and unapproved Library names as defined in the RDB
Management Data.

2. The system prompts Accept to Create or Exit to Avoid Creating New Library
Select Accept to create the specified library files.

Unapproved ==> Approved


This option is used to copy the data in the unapproved material description library to the approved
library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the library file to the approved library.
If the approved and unapproved library names are the same, the system displays an error
message.

Load/Revise Interactive
This option enables you to load entries from a neutral ASCII file into the Material Description
Library. Refer to the library descriptions earlier in this section for a listing of the neutral file
formats used in defining the delivered material data.
This option adds the contents of the neutral files to the information currently in the library or
revises an existing table in the library.
The neutral files for the delivered RDB data are contained in the delivered material description
libraries. Refer to the Report option for information on extracting the neutral files.

Operating Sequence
1. Select the Load/Revise option.
2. Select File Type
Select the type of material data to be loaded into the specified library from the display list and
select Accept.

Plant Design System (PDS) Reference Data Manager (PD_Data)

285

Material Description Data


3. Specify Neutral File Name
Key in the file specification for the neutral file that contains the data to be processed.
4. Accept to Create New Records or Exit
Select Accept to begin processing the neutral file.

The system begins processing the load/revise request.

Load/Revise Batch
This option enables you to load entries from a neutral ASCII file into the Material Description
Library via batch processing. Refer to the library descriptions earlier in this section for a listing of
the neutral file formats used in defining the delivered material data.
This option adds the contents of the neutral files to the information currently in the library or
revises an existing table in the library.
The neutral files for the delivered RDB data are contained in the delivered material description
libraries. Refer to the Report option for information on extracting the neutral files.

Operating Sequence
1. Select the Load/Revise option.
2. Select File Type
Select the type of material data to be loaded into the specified library from the display list and
select Accept.

3. Specify Neutral File Name


Key in the file specification for the neutral file that contains the data to be processed and
select Accept.
4. Accept to Submit or Specify Submit Time
Set the toggle to Submit Batch Immediately or Delayed Batch Submit Time.
For delayed submission, set the time to process the neutral file.
5. Select Accept to begin processing.

The system submits the request to the batch queue PDreference.

Replace Interactive
This option enables you to load entries from a neutral ASCII file into the Material Description
Library. Refer to the library descriptions earlier in this section for a listing of the neutral file
formats used in defining the delivered material data.
This option deletes all entries in the respective library file and then loads new entries from the
neutral file.

286

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


The neutral files for the delivered RDB data are contained in the delivered material description
libraries. Refer to the Report option for information on extracting the neutral files.

Operating Sequence
1. Select the Replace Interactive option from the Material Description Library form.
2. Select File Type
Select the type of material data to be loaded into the specified library from the display list and
select Accept.

3. Specify Neutral File Name


Key in the file specification for the neutral file that contains the data to be processed.
4. Accept to Create New Records or Exit
Select Accept to begin processing the neutral file.

Replace Batch
This option enables you to load entries from a neutral file into the Material Description Library via
batch processing. Refer to the library descriptions earlier in this section for a listing of the neutral
file formats used in defining the delivered material data.
This option deletes all entries in the respective library file and then loads new entries from the
neutral file.
The neutral files for the delivered RDB data are contained in the delivered material description
libraries. Refer to the Report option for information on extracting the neutral files.

Operating Sequence
1. Select the Replace Batch option from the Material Description Library form.
2. Select File Type
Select the type of material data to be loaded into the specified library from the display list and
select Accept.

Plant Design System (PDS) Reference Data Manager (PD_Data)

287

Material Description Data

3. Specify Neutral File Name


Key in the file specification for the neutral file that contains the data to be processed and
select Accept.
4. Accept to Submit or Specify Submit Time
Set the toggle to Submit Batch Immediately or Delayed Batch Submit Time.
For delayed submission, set the time to process the neutral file.
5. Select Accept to begin processing.

The system submits the request to the batch queue PDreference.

Report Option
The Report option enables you to create neutral files or report files using the information in the
Material Description Library. Refer to the description of the Short Material Description Library (on
page 273), Long Material Description Library (on page 279), and Specialty Material Description
Library (on page 281) for more information on the types of neutral files.

Operating Sequence
1. Select the Report option from one of the library forms.
2. Select File Type
Select the type of material data to be extracted from the specified library from the display list
and select Accept.

3. Specify Neutral File Name


Key in the name of the neutral file to be created. You can change the Node Name and File
Path information.
4. Accept or Toggle to Create Report
Select Accept to create the specified neutral file.

288

Plant Design System (PDS) Reference Data Manager (PD_Data)

Material Description Data


5. Set the toggle to Unapproved Library or Approved Library to define the source of
information to be reported. This toggle is only displayed when both the approved and the
unapproved library are being used.
6. Set the toggle to Create Neutral File to create a neutral file which can be revised and
reloaded into the library.
OR
Set the toggle to Create Report to create a report file of the information in the library. The
report output is the same as the neutral file except that the system aligns subsequent lines of
the material description left-justified to the beginning of the material description rather than the
commodity code.
For the report selection, the system displays the following options.

7. Select the reporting option.


Print / Delete submit the generated report output file to the specified print queue and
delete the output file.
Print / Save submit the generated report output file to the specified print queue and
save the output file.
Save save the output file and suppress printing.
For either of the Print options, the system displays a list of queues based on information in the
project Queue Description Library. Refer to the Project Administrator Reference Guide for
more information on the Queue Description Library and setting up print queues.
Select the queue for the required output device.
8. Select Accept to begin processing the request.

Plant Design System (PDS) Reference Data Manager (PD_Data)

289

SECTION 11

Table Checker
The Table Checker enables you to verify that all the commodity spec tables, entries, and Eden
modules for a piping materials class exist in the graphic data libraries for the project.
This process accesses the Eden code for each commodity item in the piping material class and
checks that the table names created in the physical dimension modules exist in the project
Physical Data Library. This routine checks for the existence of the tables and checks the contents
of the tables.

For Table Checker to function, there MUST be at least one piping model file created in the
project, and it must have a piping materials class (spec) defined in the Active Segment
Parameters.
The Type 63 settings of the model with the highest alphanumeric name are used as defaults
for the Table Checker reports. If weight tables are set to 'yes' for this model, then Table
Checker will search for and report on found and missing weight tables. If MTO Bolt
Calculation is set to 'almost precise,' Table Checker will search for the 'almost precise' tables
(table naming format = G12). If set to 'precise,' Table Checker will search for 'precise' tables
(table naming format = G12T).
When the spec contains PIPING/TUBE and PIPE/TUBING, Table Checker will report as per
Type 63 data settings.
If Component Placement is set to PIPING for Pipe Commodity Name and TUBE for Tube
Commodity Name, Table Checker uses these commodity names and searches for PDPIPING
and PDTUBE in the Graphic Commodity Library. If there are any other PIPE and TUBING values
found in the spec that do not match with Type 63, Table Checker assumes that this is a regular
commodity item. It uses the model_code and searches for SPmodel_Code in the Graphic
Commodity Library.
If Component Placement is set to PIPE for Pipe Commodity Name and TUBING for Tube
Commodity Name, Table Checker uses these commodity names and searches for PDPIPE and
PDTUBING in the Graphic Commodity Library. If there are any other PIPING and TUBE values
found in the spec that do not match with Type 63, Table Checker assumes that this is a regular
commodity item. It uses the model_code and searches for SPmodel_code in the Graphic
Commodity Library.
In such cases, if the model_code of the item is the same as the commodity_name that matches
with Type 63 data, the Table Checker may report the same value under both Eden Found and
Eden Not Found. In other words, Table Checker reports the commodity_name under Eden
Found and the model_code under Eden Not Found.

Features
The Table Checker provides the following features.
Reports on one piping material class selected from the available entries in the
Specification/Material Database.
Reports on all valid sizes in the size range for each piping commodity using the Nominal
Piping Diameter table for that piping materials class.

Plant Design System (PDS) Reference Data Manager (PD_Data)

291

Table Checker

Reports dimensional tables used during the placement of each piping commodity in the piping
materials class. This includes the table names, the types of tables, the existence of those
tables (found or not found), and the output values from those tables.
Reports Piping Eden modules used during the placement of each piping commodity in the
piping materials class. This includes the Piping Eden module names and the existence of
those modules (found or not found).
Reports dimensional tables used for all piping commodities in the entire report (the piping
materials class). This includes the table names, the revision dates for those tables, and the
source Dimension Table Library.
Reports bolt tables for each piping commodity with bolted ends.
Reports Piping Eden modules used for all piping commodities in the entire report (the piping
materials class). This includes the Piping Eden module names and the existence of those
modules (found or not found).
Verifies that a material description exists in the Material Description Library for any piping
commodities defined in the Material Reference Database. The commodity code as defined in
the Piping Commodity Specification Data Table (PDtable_202) or the Piping Commodity
Size-Dependent Material Data Table (PDtable_211) is used to verify the material description.
Verifies that a material description exists in the Material Description Library for any implied
component defined in the Piping Commodity Implied Material Data Table (PDtable_212) of the
Material Reference Database.
Verifies that a material description exists in the Specialty Material Description Library for any
piping specialty or instrument defined in the Material Reference Database.
Provides a detailed error report of any tables or table entries that were found missing during
the processing of the piping materials class.

For tables containing schedule thickness calculations as part of the name, the
calculations are replaced with preferred thickness unless no preferred thickness is found for
that size or PMC thickness table.
If any errors are encountered during execution, the system appends the errors to the end of the
report output. In the case of severe errors, it creates a file named RPT_ERR.LOG.
Commodity items with option codes greater than 5000 (spec implied components) are not
checked.

Format Files
The Table Checker uses report format files to define the report output. It uses the same reporting
indices as any other report from the Piping Job Specification data (the C indices). Refer to
Format Files in the Report Manager Reference Guide for more information on these indices.
The following example report formats for the Table Checker are included in the PD_DATA sample
directory (\win32app\ingr\pddata\sample\format/). Refer to the Report Manager Reference
Guide for more information on report type.
tbl_chk_1.fmt
This report format reports on virtually all data generated by the Table Checker. It is a
combination of the following sample report formats: tbl_chk_2.fmt, tbl_chk_3.fmt, and
tbl_chk_4.fmt.
It reports the piping commodities in the selected piping materials class with the dimension
tables and Piping Eden modules used, including a list of all entries read in the dimension
tables. It also lists all dimension tables and Piping Eden modules required for those piping
commodities, but not available in the Reference Database.
tbl_chk_2.fmt

292

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

This report format reports the dimension tables and Piping Eden modules used by each piping
commodity in the applicable piping materials class.
tbl_chk_3.fmt
This report lists all entries read in dimension tables for the applicable piping materials class.
tbl_chk_4.fmt
This report format reports a total list of dimension tables and Piping Eden modules used for
the applicable piping materials class. It also lists all dimension tables and Piping Eden
modules required for those piping commodities, but not available in the Reference Database.
tbl_chk_5.fmt
This report verifies the reference data for any piping specialties defined in the Reference
Database (pdtable_203).
tbl_chk_6.fmt
This report verifies the reference data for any instruments defined in the Reference Database
(pdtable_204).

Table format 5 or 6 must be used when the discrimination file is created with the No Piping
Material Class button selected.

Table Checker Form


The Report Manager form enables you to generate reports from the project, design, and
reference database files with the report definition data. The report record and the location
records for each discrimination data file and format file are stored in the project control database.
These numbered records are used to locate ASCII files on their specified nodes.

Report Format Displays the Report Format form, which you can use to create, revise,
copy, or delete the record of a format file (not the format file). For more information, see
Report Format Form (on page 295).

Plant Design System (PDS) Reference Data Manager (PD_Data)

293

Table Checker

Report Discrimination Data Displays the Discrimination Data form, which you can use
to create, revise, copy, or delete the record of a discrimination data file as well as the file itself.
For more information, see Discrimination Data Form (on page 298).
Report Displays the Report form, which you can use to create, revise, delete, and
approve report records and report files. For more information, see Report Form (on page
303).
Report Management Data Displays the Report Management Defaults form, which you
can use to create a record in the project control database of the default nodename and path for
the report definition files. This option is primarily used for setup. For more information, see
Report Management Defaults Form (on page 311).

Using the Report Commands


Understanding Report Files and Records
The Table Checker uses the discrimination data files, format files, and database records that
represent these files to generate reports. The following definitions explain all of the files and
records in the reporting process.

Format File and Record


The format file is a user-defined, ASCII file which must be created with a text editor outside of the
Table Checker. It contains special indices identifying what data appears in the report and how
the data is sorted. It also defines how the data is formatted in the report. Without the format
file(s), Table Checker reports cannot be processed. A set of basic format files is delivered for
each type of reporting.
Using the Report Format option, you can create a numbered record for each format file so that it
can be accessed for report processing. The format record is a record in the Project Control
Database used to name and locate a specific format file. Unlike the format file, the format record is
created interactively. It is called a record to classify it as a block of data that is used for report
processing but is not an actual file.

Discrimination Data File and Record


The discrimination data file limits the report to only the specified database occurrences. It is an
ASCII file that is created interactively using the Table Checker.
The discrimination data record is a record in the Project Control Database used to name and
locate a specific discrimination data file. There is a uniquely-numbered record for each
discrimination data file so that it can be accessed for report processing. This is the same way
that the format record is used to access a format file.

Report Output and Record


The Table Checker creates a report using the specified format, discrimination, and search criteria
data files, and places it in the specified directory on the specified node.
The report record names or defines locations for all of the files that are necessary to generate a
report, including the report output. (It is called a record to classify it as a block of data that is used
for report processing but is not an actual file.)

Group Workflow
There is a definite workflow for at least the first time you create a report. First, use the Report
Management Data option to specify defaults for the nodename and path of the report definition
files. By defining the defaults first, you can prevent keying in a nodename and path on each form.

294

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
If you want to use a different nodename or path than the defined default, simply place a data point
in that field and key in the modification.
The following steps can be done in any order: create your format record, discrimination data
record, and discrimination data file using the Report Format and Report Discrimination Data
options. Reports cannot be generated until the format file, the discrimination data file, and their
corresponding records have been established.
Finally, use the Report option to create the actual report.

Report Format Form


When you choose the Report Format option from the Report Manager form, the Report Format
form is displayed.

This form enables you to create, copy, revise, or delete a record of the location of the format file in
the project control database. An option is also provided that enables you to copy a record and its
corresponding ASCII format files.
The format file defines the data that will be reported and the way in which that data will be
displayed. Reports cannot be generated unless a format file exists and a record of the file's
location has been entered into the project control database.
Create Displays the Format Creation/Revision form, which enables you to add a new
record of a format file in the project control database. For more information, see Format
Creation/Revision Form (on page 296).
Copy Displays the Format Creation/Revision form, which copies the record of an existing
format file from the project control database along with the corresponding ASCII format file.
For more information, see Format Creation/Revision Form (on page 296).
Revise Displays the Format Creation/Revision form, which modifies a record of an
existing format file in the project control database. For more information, see Format
Creation/Revision Form (on page 296).

Plant Design System (PDS) Reference Data Manager (PD_Data)

295

Table Checker

Delete Displays the Deletion form, which deletes an existing record of a format file from the
project control database. If the record of the format file is deleted, reporting cannot be
performed. For more information, see Format Deletion Form (on page 297).

Format Creation/Revision Form


When you choose Create, Copy, or Revise from the Report Format form, the Format
Creation/Revision form is displayed.

This form creates or revises a record in the project control database; this record defines the
location of a format file. The format file itself defines the contents and format of the report. Both
the location specification and the format file must exist to report on PDS data.
Number A unique number of up to 24 characters. Specifies the short name in the project
control database used to identify the record of the format file.
Description A description of up to 40 characters for the format file.
File Specification The file name of the format file to reference.
Path The disk location of the format file. This field retains the active setting.
Node The nodename of the system on which the format file is located. This field retains
the active setting.

Before Using this Form


You must have created an ASCII format file. A set of basic format files is delivered with the
PD_Data product in the ~\pddata\sample\format directory. The file for MTO reporting is named
piping_#.fmt.

Operating Sequence
1. Select Create, Copy, or Revise.

A list of available records displays for copy or revision. To create a database record, go to

296

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
Step 3.
2. Select Report Format
From the displayed list, select the record to be copied or revised. Then click Accept.

Key-in fields are displayed for you to specify the required database information.
3. Specify Report Format Data
Type information in each of the displayed fields, taking care to press Enter in each field.
Then click Accept.

The project control database is updated.

Format Deletion Form


When you choose Delete, the Deletion form is displayed.

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

Plant Design System (PDS) Reference Data Manager (PD_Data)

297

Table Checker

Discrimination Data Form


When you select Report Discrimination Data from the Report Manager form, the
Discrimination Data form is displayed.

This form creates, copies, revises, and deletes a discrimination data file from the specified
directory. The associated record in the project control database is also copied, revised, or
deleted as needed.
A discrimination data file is an ASCII file that designates which models will be included in a report.
That is, discrimination data specifies the scope of the report. The project control database record
specifies the name and location of the discrimination data file that is to be associated with a
specific report.
Create Displays the Discrimination Data Creation form, which creates a new
discrimination data file. The associated project control database record is also created. For
more information, see Discrimination Data Creation Form (on page 299).
Copy Displays the Discrimination Data Revision form, which copies an existing data file.
The associated project control database record is also copied. For more information, see
Discrimination Data Revision Form (on page 300).
Revise Displays the Discrimination Data Revision form, which modifies discrimination
data. You can use this option to revise the contents of the discrimination data file, the
location of the discrimination file, and the associated record in the project control database.
For more information, see Discrimination Data Revision Form (on page 300).
Delete Displays the Deletion form, which deletes a discrimination data file as well as its
associated record in the project control database. For more information, see Discrimination
Data Deletion Form (on page 301).

298

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

Discrimination Data Creation Form


When you select Create from the Discrimination Data form, the Discrimination Data Creation
form is displayed.

This form creates a discrimination data file in a specified directory. It also creates a
corresponding record in the project control database. In addition, you can use this form to specify
segment and component search criteria.
If you use this form to specify search criteria data and you specify search criteria data using
the Report Search Criteria option, the data specified using the Report Search Criteria option
takes precedence.
Number The unique number, up to 24 characters, that is the short name of the
discrimination data record in the project control database.
Description The description, up to 40 characters, of the discrimination data record in the
project control database.
File Specification The file name of the discrimination data record to be created.
File Path The disk location of the discrimination data file. This field retains the active
settings.
File Node The nodename of the system on which the discrimination data file is located.
This field retains the active settings.
Piping Materials Class Key in up to 16 alphanumeric characters for the piping materials
class.
Approved Piping Job Spec Defines the database to be reported: approved or
unapproved.
Select Piping Materials Class Sets the piping materials class(es) in the
Specification/Material Reference Database which defines the tables to be checked.
No Piping Materials Class When selected, indicates to the system that either the piping
specialties or instruments will be verified by Table Checker.

Plant Design System (PDS) Reference Data Manager (PD_Data)

299

Table Checker
Either format 5 or 6 must be used when the discrimination data is created with the No
Piping Materials Class button selected.

Operating Sequence
1. From the Report Discrimination Data form, select Create.

The Discrimination Data Creation form displays.


2. Specify Discrimination Data
In the fields provided, key in the number, description, file specification, path, and node.
3. Select additional options as needed to define the report discrimination data. Then select
Accept.
After including any models or search criteria for the discrimination data file, be sure
to select the final Accept. Because you must accept many forms while specifying the
discrimination data, it is easy to forget this step. Even though you may have accepted many
of the specifications, the discrimination data file is not actually created until you select Accept
on the Report Discrimination Data form.

Discrimination Data Revision Form


When you select Copy or Revise from the Discrimination Data form, the Discrimination Data
Revision form is displayed.

This form revises an existing discrimination data file. It also copies an existing discrimination
data file; you can then use the revision options to modify the copy as needed. The corresponding
records in the project control database are copied and/or modified as needed. In addition,
options are provided for you to modify segment and component search criteria data.
If you use this form to specify search criteria data and you specify search criteria data using
the Report Search Criteria option, the data specified using the Report Search Criteria option
takes precedence.
Number The unique number, up to 24 characters, that is the short name of the
discrimination data record in the project control database.
Description The description, up to 40 characters, of the discrimination data record in the
project control database.
File Specification The file name of the discrimination data record to be created.
File Path The disk location of the discrimination data file. This field retains the active
settings.

300

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

File Node The nodename of the system on which the discrimination data file is located.
This field retains the active settings.
Piping Materials Class Select one or more piping materials classes from this list of loaded
classes.
Approved Piping Job Spec Defines the database to be reported: approved or
unapproved.
Select Piping Materials Class Sets the piping materials class(es) in the
Specification/Material Reference Database which defines the tables to be checked.
No Piping Materials Class When selected, indicates to the system that either the piping
specialties or instruments will be verified by Table Checker.
Either format 5 or 6 must be used when the discrimination data is created with the No
Piping Materials Class button selected.

Operating Sequence
1. From the Report Discrimination Data form, select Copy or Revise.

The Discrimination Data Revision form is displayed.


2. Specify Discrimination Data
In the fields provided, key in the number, description, file specification, path, and node.
3. Select additional options as needed to define the report discrimination data. Then select
Accept.
After updating any models or search criteria for the discrimination data file, be sure
to select the final Accept. Because you must accept many forms while specifying the
discrimination data, it is easy to forget this step. Even though you may have accepted many
of the specifications, the discrimination data file is not actually updated until you select Accept
on the Report Discrimination Data form.

Discrimination Data Deletion Form


When you choose Delete, the Deletion form is displayed.

Plant Design System (PDS) Reference Data Manager (PD_Data)

301

Table Checker

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

302

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

Report Form
When you select Report from the Report Manager form, the Report form is displayed.

This form creates, revises, and deletes report records and report files. A report record holds
specifications for a report; these specifications include the report name, the report description, and
which format file, discrimination data file, and search criteria data file to use to generate a report.
The report name is not the title that is printed on the report; the title is included in the format
file.
At the end of each report, a parameters page is included that contains the following information:
Report Output The report number, report title, report creation/revision date, and report
node, path, and file name.
Format The report format number, description, and node, path, and file name.
Discrimination Data The report discrimination data number, description, and file location
(network address, path, and file name). The following discrimination data is also included:
list of model numbers (with discipline), volume (if applicable), search criteria (if applicable),
and sorting sequence.
Search Criteria The report search criteria number, description, and file location (node,
path, and file name. The following search criteria data is also included: list of model
numbers (with discipline), volume (if applicable), search criteria (if applicable), and sorting
sequence.

Options

Create Displays the Report Creation form, which creates a report record and generates a
report. For more information, see Report Creation Form (on page 304).
Revise Displays the Revise Report form, which regenerates a report from an existing or
revised report record. For more information, see Revise Report Form (on page 306).

Plant Design System (PDS) Reference Data Manager (PD_Data)

303

Table Checker

Delete Displays the Deletion form, which deletes an existing report record and the
corresponding report. For more information, see Report Deletion Form (on page 308).
Approve Displays the Report Approval form, which approves an existing report. For more
information, see Report Approval Form (on page 309).
Multi-Create Displays the Report Multiple Submit form, which submits multiple reports to
the printer. For more information, see Report Multiple Submit Form (on page 310).

Report Creation Form


When you select Create from the Report form, the Report Creation form is displayed.

Use this form to create a report record and to generate a report. Because report records are
stored in the project control database, you can use them over and over again as needed.
Report Number The 24-character number that uniquely identifies the record of the report
file in the project control database. This is sometimes referred to as the report file short
name.

304

The Table Checker Report Number must not contain spaces. If there are spaces in
the number, the report will not be submitted to the batch queue.
Report Title The 40-character descriptive name of the report file. This is not the title in the
actual report, but is rather the title of the report record. The title of the report is contained in
the format file.
Report File Spec The name of the report output file (up to 14 characters).
Report File Path The disk location for the report output file. This field retains the active
settings, and it is automatically populated if you have specified this data on the Report
Management Data form. For more information, see Report Management Defaults Form (on
page 311).
Report Node The name of the system on which the report output file will be located. This
field retains the active settings, and it is automatically populated if you have specified this data

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

on the Report Management Data form. For more information, see Report Management
Defaults Form (on page 311).
Report Format File The name of the format file to be used to generate the active report.
When you select this field, a list of available format files is displayed. Select the appropriate
format file, and click Accept.
Report Discrimination File The name of the discrimination data file to be used to generate
the active report. When you select this field, a list of available discrimination data files is
displayed. Select the appropriate discrimination data file, and click Accept.
Report Search Criteria The name of the search criteria data file to be used to generate the
active report. When you select this field, a list of available search criteria files is displayed.
Select a search criteria file, and click Accept.
Select this field a second time to specify a different search criteria file. To clear a
specification, click Accept without selecting a file.
If the report discrimination data selected for the active report has search criteria data
defined within it, and you specify a search criteria in this field, the search criteria specified in
the Report Search Criteria field takes precedence over the search criteria contained in the
discrimination data.
Revision Number The revision number (up to three characters) for the report.
Last Revision Number The revision number of the last report generated. This is a
read-only field; you cannot edit it.
Revised By The user (up to five characters) who checked the report. This field is optional.
Revision Description The description (up to 40 characters) of the report revision. This
field is optional.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit Immediately/Submission is Delayed Specifies when the report will be
processed. When this toggle is set to Submission is Delayed, additional fields display for
you to specify the date and time that the report is to be generated.

Operating Sequence
1. From the Report form, select Create.

The Report Creation form is displayed.


2. Specify Report Data
Key in the report record information. Then select the appropriate report format file,
discrimination data file, and search criteria data file.
3. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
4. Specify whether the report is to be generated now (Submit Immediately) or later
(Submission is Delayed). If you choose delayed submission, specify the date and time that
the report is to be submitted.
5. Click Accept to save the report file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

305

Table Checker

Revise Report Form


When you select Revise from the Report form, the Revise Report form is displayed.

This form revises an existing report record and generates a report from the project control
database. An option is also provided to update (in some cases) the report record without
generating a report output file. Similarly, you can choose to generate an updated report output
file without updating the report record.
Report Number The 24-character number that uniquely identifies the record of the report
file in the project control database. This is sometimes referred to as the report file short
name.
Report Title The 40-character descriptive name of the report file. This is not the title in the
actual report, but is rather the title of the report record. The title of the report is contained in
the format file.
Report File Spec The name of the report output file (up to 14 characters).
Report File Path The disk location for the report output file. This field retains the active
settings.
Report Node The name of the system on which the report output file will be located. This
field retains the active settings.
Report Format File The name of the format file to be used to generate the active report.
When you select this field, a list of available format files is displayed. Select the appropriate
format file, and click Accept.
Report Discrimination File The name of the discrimination data file to be used to generate
the active report. When you select this field, a list of available discrimination data files is
displayed. Select the appropriate discrimination data file, and click Accept.
Report Search Criteria The name of the search criteria data file to be used to generate the
active report. When you select this field, a list of available search criteria files is displayed.
Select a search criteria file, and click Accept.

306

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
Select this field a second time to specify a different search criteria file. To clear a
specification, click Accept without selecting a file.

If the report discrimination data selected for the active report has search criteria data
defined within it, and you specify a search criteria in this field, the search criteria specified in
the Report Search Criteria field takes precedence over the search criteria contained in the
discrimination data.
Revision Number The revision number (up to three characters) for the report.
Last Revision Number The revision number of the last report generated. This is a
read-only field; you cannot edit it.
Revised By The user (up to five characters) who checked the report. This field is optional.
Revision Description The description (up to 40 characters) of the report revision. This
field is optional.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit to Batch Immediately/Delayed Submit to Batch Specifies when the report will
be processed. When this toggle is set to Delayed Submit to Batch, additional fields display
for you to specify the date and time that the report is to be generated.
Revise Data Only/Revise Report and Data Specifies revision of the report data only
(Revise Data Only) or revision of the report data and the report output file (Revise Report
and Data). To revise the report specification without updating the report output file, make the
necessary changes, set this toggle to Revise Data Only, and click Accept. To revise the
report output file only, set this toggle to Revise Report and Data without modifying any of the
fields, and click Accept. To modify both the report file and the report output file, make the
necessary changes, set this toggle to Revise Report and Data, and click Accept.
If you update any field other than Report Number and Report Title, this toggle is
automatically set to Revise Report and Data, and the report output file is generated.

Operating Sequence
1. From the Report form, select Revise.

The Report Creation form is displayed with a list of available report files.
2. Select Report
From the displayed list, select the report to be revised. Then click Accept.

The fields update to display the selected report file specifications.


3. Revise Report Information
Update the report record information as needed.
4. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
5. Specify whether the report is to be generated now (Submit Immediately) or later
(Submission is Delayed). If you choose delayed submission, specify the date and time that
the report is to be submitted.
6. Click Accept to save the report file.

Plant Design System (PDS) Reference Data Manager (PD_Data)

307

Table Checker

Report Deletion Form


When you choose Delete, the Deletion form is displayed.

This form deletes a report record from the project control database and can optionally delete the
associated file. This form is used with format files and their database records, discrimination data
files and their database records, and search criteria files and their database records.
Number/Description Displays the 24-character short name and the 40-character
description of a report record in the project control database.
Delete File/Do Not Delete File Determines whether the associated file is deleted. When
set to Delete File, the database record is deleted along with the associated file. When set to
Do Not Delete File, only the database record is deleted.

Operating Sequence
1. Select Report Format
From the displayed list, select the database record to be deleted.
2. Set the Delete File/Do Not Delete File toggle as needed. Then click Accept.

The specified record is deleted. If specified, the associated file is also deleted.

308

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker

Report Approval Form


When you select Approve from the Report form, the Report Approval form is displayed.

Use this form to select a report to approve. Approving a report means that a database attribute is
set from not approved (the default) to approved. This approval status provides a way for you to
flag reports that you have run and verified that the output data is valid. When a report is revised,
the approval status is automatically reset to not approved.
Number The 24-character unique name (as called short name) of the report record.
Description The 40-character description of the report record.

Operating Sequence
1. From the Report form, select Approve.

The Report Approval form is displayed.


2. From the displayed list, select a report to approve. Then click Accept.

The Approval form is displayed.


For more information, see Approval/Revision Interface Form in the PD_Report User's Guide.

Plant Design System (PDS) Reference Data Manager (PD_Data)

309

Table Checker

Report Multiple Submit Form


When you select Multi-Create from the Report form, the Report Multiple Submit form is
displayed.

Use this form to submit multiple reports at the same time.


Number The 24-character number that uniquely identifies the record of the report file in the
project control database. This is sometimes referred to as the report file short name.
Description The 40-character descriptive name of the report file.
Print/Delete Submits the report output file to the specified print queue and then deletes the
report output file. When you select this option, a list of available print queues is displayed.
Click on a queue to select it.
Print/Save Submits the report output file to the specified print queue and saves the report
output file. When you select this option, a list of available print queues is displayed. Click on
a queue to select it.
Save Saves the report output file without printing the report.
Submit to Batch Immediately/Delayed Submit to Batch Specifies when the report will
be processed. When this toggle is set to Delayed Submit to Batch, additional fields display
for you to specify the date and time that the report is to be generated.

Operating Sequence
1. From the Report form, select Multi-Create.

The Report Multiple Submit form is displayed.


2. Select Reports for Submission
From the displayed list, select the reports to submit. Highlighted reports are selected; select a
highlighted report to remove the highlight and to not submit the report.

310

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
3. Select the appropriate print/save/delete option, and select a queue if the report is to be
printed.
4. Specify whether the report is to be generated now (Submit to Batch Immediately) or later
(Delayed Submit to Batch). If you choose delayed submission, specify the date and time
that the report is to be submitted.
5. Click Accept to submit the reports.

Report Management Defaults Form


When you select Report Management Data from the Report Manager form, the Report
Management Defaults form is displayed.

This form creates a record in the project control database of the node name and path of the report
definition files. This option is used primarily for setup.
Report Path Specifies the default path of the report output files.

It is recommended that you not send output reports to your system's temporary (that is,
tmp or temp) directory.
Report Node Specifies the default node name of the system on which report output files
are located.
Report Format Path Specifies the default path of the format files.
Report Format Node Specifies the default node name of the system on which format files
are located.
Report Discrimination Data Path Specifies the default path of the discrimination data
files.
Report Discrimination Data Node Specifies the default node name of the system on
which discrimination data files are located.
Report Search Criteria Data Path Specifies the default path of the report search criteria
data files.

Plant Design System (PDS) Reference Data Manager (PD_Data)

311

Table Checker

Report Search Criteria Data Node Specifies the default node name of the system on
which report search criteria data files are located.

Operating Sequence
1. From the Report Manager form, select Report Management Data.

The Report Management Defaults form is displayed.


2. Accept or Exit
In the fields provided, key in the default paths and node names for the report output files,
format files, discrimination data files, and search criteria data files. Then click Accept.

Sample Table Checker Output


The following is a listing of selected pages from the table checker output for Piping Materials Class
1C0031.
21-Apr-92
Page:
1
SIZE-INDEPENDENT SPEC DATA
__________________________
Description:
Gate valve, CL800, SWE, BB, OS&Y,
ASTM-A105, trim 8, Smith 800
Piping Class: 1C0031
Size Range: 1st 3/4IN 1-1/2IN
2nd Option:
End Preparation(s): SWE (421)
Rating(s): CL800
End geometry standard(s): Default (5)
Body geometry standard: Smith 1 (4625)
Maximum allowable temperature: -9999
Material Grade: A105 (150)
Modifier: 3
Fabrication category: CSFF (7)
Note 1: Note 2: PDS Reference data
AABBCC: 6Q1C01

312

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
Commodity Code: VAUSAHGAAA
Weight Code: 490 pcf (52)
EDEN Modules Tables
______
GATR
FEM_420_800_5
V1_AMS
GATR_4625_420_800_A
VALVE_2_AMS VAUSAHGAAA
V1 GATR_FEM_800_3_A
OP_3
OPERATOR_3
OP3
21-Apr-92 Page: 2
SIZE-INDEPENDENT SPEC DATA
__________________________
Description: Gate valve, CL800, SWE, BB, OS&Y, full
port, ASTM-A105, trim 8, Smith 888
Piping Class: 1C0031
Size Range: 1st 3/4IN 1-1/2IN
2nd - Option: Full port (24)
End Preparation(s): SWE (421)
Rating(s): CL800
End geometry standard(s): Default (5)
Body geometry standard: Smith 1 (4625)
Maximum allowable temperature: -9999
Material Grade: A105 (150)
Modifier: 3
Fabrication category: CSFF (7)
Note 1: Note 2: PDS Reference data
AABBCC: 6Q1C01
Commodity Code: VAUSAHGCAA
Weight Code: 490 pcf (52)
EDEN Modules
Tables
______
GATF
FEM_420_800_5

Plant Design System (PDS) Reference Data Manager (PD_Data)

313

Table Checker
V1_AMS
VALVE_2_AMS
V1
OP_3
OPERATOR_3
OP3

GATF_4625_420_800_A
VAUSAHGCAA
GATF_FEM_800_3_A

21-Apr-92 Page: 3
SIZE-INDEPENDENT SPEC DATA
__________________________
Description: Gate valve, CL150, RFFE, BB, OS&Y,
ASTM-A105, trim 8, Smith 815
Piping Class: 1C0031
Size Range: 1st 3/4IN 1-1/2IN
2nd - Option: RFFE (221)
End Preparation(s): RFFE (21)
Rating(s): CL150
End geometry standard(s): Default (5)
Body geometry standard: ANSI-B16.10 (40)
Maximum allowable temperature: -9999
Material Grade: A105 (150)
Modifier: 3
Fabrication category: CSFF (7)
Note 1: Use at flanged equipment connections.
Note 2: PDS Reference data
AABBCC: 6Q1C01
Commodity Code: VAABAHGGAA
Weight Code: 490 pcf (52)
EDEN Modules
GAT
V1_AMS
VALVE_2_AMS
V1

314

Tables
______
BLT_20_150_5
GAT_40_20_150_A
VAABAHGGAA
GAT_BLT_150_3_A

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
OP_3
OPERATOR_3
OP3

STUD_20_150_5

21-Apr-92 Page: 133


SIZE-DEPENDENT SPEC DATA
________________________
Piping Class: 1C0031
AABBCC: 6Q1C01
1st Size 2nd Size Physical Data
Weight Generic Specific Sub-Component
________ ________ _______ ________ _____________
3/4IN 3/4IN
4.5Lb 1.1715In, 0.4375In Undefined, Undefined, 1.125In 11In, 4In
1IN 1IN
6.25Lb 1.4538In, 0.4375In Undefined, Undefined, 1.375In 13In, 5.5In
1-1/2IN 1-1/2IN
12Lb 2.0575In, 0.4375In Undefined, Undefined, 1.5625In 16.125In, 5.75In
21-Apr-92 Page: 134
SIZE-DEPENDENT SPEC DATA
________________________
Piping Class: 1C0031
AABBCC: 6Q1C01
1st Size 2nd Size Physical Data
Weight Generic Specific Sub-Component
________ ________ _______ ________ _____________
3/4IN 3/4IN
6.25Lb 1.1715In, 0.4375In Undefined, Undefined, 1.125In 11In, 4In
1IN 1IN
9.75Lb 1.4538In, 0.4375In Undefined, Undefined, 1.375In 13In, 5.5In
1-1/2IN 1-1/2IN
21.75Lb 2.0575In, 0.4375In Undefined, Undefined, 1.5625In 16.125In, 5.75In
21-Apr-92 Page: 376
TABLES NOT FOUND
________________
Tables Not Found Table Library
________________ _____________
REDC_39_300_S$10_300_S$XS_52 Physical Data Library
REDE_39_300_S$10_300_S$XS_52 Physical Data Library
STUD_120_150_5
STUD_120_150_80
STUD_120_300_5
STUD_160_150_5
STUD_160_150_80
21-Apr-92 Page: 377

Plant Design System (PDS) Reference Data Manager (PD_Data)

315

Table Checker
TABLES FOUND
____________
Tables Found Table Library Table Revision Date
____________ _____________ ___________________
BALR_3028_420_600_A Physical Data Library Thu Jan 3 09:46:45 1991
BALR_FEM_600_9_A Physical Data Library Thu Jan 3 10:16:28 1991
BALSP_40_20_150_A Physical Data Library Thu Jan 3 10:01:23 1991
BALSP_BLT_150_9_A Physical Data Library Thu Jan 3 10:16:28 1991
BFYHP_4200_160_150_A Physical Data Library Thu Jan 3 10:08:15 1991
BFYHP_BLT_150_17_A Physical Data Library Thu Jan 3 10:16:33 1991
BLPAD_1026_120_150_A Physical Data Library Thu Jan 3 09:28:00 1991
BLPAD_1026_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:01 1991
BLPAD_146_120_150_A Physical Data Library Thu Jan 3 09:28:48 1991
BLPAD_146_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:51 1991
BLSPA_1026_120_150_A Physical Data Library Thu Jan 3 09:28:01 1991
BLSPA_1026_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:02 1991
BLSPA_146_120_150_A Physical Data Library Thu Jan 3 09:28:49 1991
BLSPA_146_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:52 1991
BLSPC_146_120_150_A Physical Data Library Thu Jan 3 09:28:50 1991
BLSPC_146_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:53 1991
BLSPC_146_120_300_A Physical Data Library Thu Jan 3 09:28:56 1991
BLSPC_146_120_300_NREQD_52 Physical Data Library Thu Jan 3 09:28:59 1991
BLSPO_146_120_150_A Physical Data Library Thu Jan 3 09:28:51 1991
BLSPO_146_120_150_NREQD_52 Physical Data Library Thu Jan 3 09:28:54 1991
BLSPO_146_120_300_A Physical Data Library Thu Jan 3 09:28:57 1991
BLSPO_146_120_300_NREQD_52 Physical Data Library Thu Jan 3 09:29:00 1991
BLT_120_150_5 Physical Data Library Thu Jan 3 10:17:06 1991
BLT_120_150_80 Physical Data Library Thu Jan 3 10:17:06 1991
BLT_120_300_5 Physical Data Library Thu Jan 3 10:17:09 1991
BLT_160_150_5 Physical Data Library Thu Jan 3 10:17:23 1991
BLT_160_150_80 Physical Data Library Thu Jan 3 10:17:24 1991
BLT_20_150_5 Physical Data Library Thu Jan 3 10:17:29 1991
BLT_20_150_80 Physical Data Library Thu Jan 3 10:17:30 1991
BLT_20_150_81 Physical Data Library Thu Jan 3 10:17:31 1991
BLT_20_300_29 Physical Data Library Thu Jan 3 10:17:38 1991
BLT_20_300_5 Physical Data Library Thu Jan 3 10:17:40 1991
BLT_20_300_80 Physical Data Library Thu Jan 3 10:17:42 1991
CAPBV_5150_300_A Physical Data Library Thu Jan 3 10:10:17 1991
CAPBV_5150_300_S$10_52 Physical Data Library Thu Jan 3 10:10:51 1991
CAPBV_5150_300_S$STD_52 Physical Data Library Thu Jan 3 10:11:03 1991
CAPBV_5150_300_S$XS_52 Physical Data Library Thu Jan 3 10:11:07 1991
CAPOT_5375_420_3000_A Physical Data Library Thu Jan 3 10:11:19 1991
CAPOT_5375_420_3000_NREQD_52 Physical Data Library Thu Jan 3 10:11:22 1991
CKLR_4625_420_800_A Physical Data Library Thu Jan 3 10:09:40 1991
CKS_40_20_150_A Physical Data Library Thu Jan 3 10:01:26 1991
CKWF_40_120_150_A Physical Data Library Thu Jan 3 10:01:12 1991
CPL_41_420_3000_A Physical Data Library Thu Jan 3 10:06:46 1991
CPL_41_420_3000_NREQD_52 Physical Data Library Thu Jan 3 10:06:49 1991
E45LR_39_300_A Physical Data Library Thu Jan 3 09:52:46 1991
E45LR_39_300_S$10_52 Physical Data Library Thu Jan 3 09:54:04 1991
E45LR_39_300_S$STD_52 Physical Data Library Thu Jan 3 09:59:04 1991
E45LR_39_300_S$XS_52 Physical Data Library Thu Jan 3 10:00:12 1991
E45_41_420_3000_A Physical Data Library Thu Jan 3 10:06:46 1991
E45_41_420_3000_NREQD_52 Physical Data Library Thu Jan 3 10:06:50 1991

316

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
E90LR_39_300_A Physical Data Library Thu Jan 3 09:52:47 1991
E90LR_39_300_S$10_52 Physical Data Library Thu Jan 3 09:54:04 1991
E90LR_39_300_S$STD_52 Physical Data Library Thu Jan 3 09:59:30 1991
E90LR_39_300_S$XS_52 Physical Data Library Thu Jan 3 10:00:12 1991
E90SR_58_300_A Physical Data Library Thu Jan 3 10:11:49 1991
E90SR_58_300_S$STD_52 Physical Data Library Thu Jan 3 10:11:58 1991
E90_41_420_3000_A Physical Data Library Thu Jan 3 10:06:47 1991
E90_41_420_3000_NREQD_52 Physical Data Library Thu Jan 3 10:06:51 1991
EOLLR_1575_300_S$STD_300_S$160_52 Physical Data Library Thu Jan 3 09:39:37
1991
EOLLR_1575_300_S$STD_300_S$160_A Physical Data Library Thu Jan 3 09:39:42
1991
21-Apr-92 Page: 378
TABLES FOUND
____________
Tables Found Table Library Table Revision Date
____________ _____________ ___________________
FBLD_254_20_150_NREQD_52 Physical Data Library Thu Jan 3 09:44:58 1991
FBLD_35_20_150_NREQD_52 Physical Data Library Thu Jan 3 09:48:28 1991
FEM_420_150_5 Physical Data Library Thu Jan 3 10:20:07 1991
FEM_420_3000_5 Physical Data Library Thu Jan 3 10:20:10 1991
FEM_420_300_5 Physical Data Library Thu Jan 3 10:20:48 1991
FEM_420_600_5 Physical Data Library Thu Jan 3 10:20:50 1991
FEM_420_800_5 Physical Data Library Thu Jan 3 10:20:51 1991
FEM_440_800_5 Physical Data Library Thu Jan 3 10:21:03 1991
FOLHC_1575_300_NREQD_420_3000_52 Physical Data Library Thu Jan 3 09:31:30
1991
FOLHC_1575_300_NREQD_420_3000_A Physical Data Library Thu Jan 3 09:31:44
1991
FOWNAW_66_20_300_300_300_52 Physical Data Library Thu Jan 3 10:12:47 1991
FOWNAW_66_20_300_300_A Physical Data Library Thu Jan 3 10:12:51 1991
FRSW_6_20_150_420_150_A Physical Data Library Thu Jan 3 10:14:14 1991
FRSW_6_20_150_420_150_S$160_52 Physical Data Library Thu Jan 3 10:14:15
1991
FRSW_6_20_300_420_300_A Physical Data Library Thu Jan 3 10:14:18 1991
FRSW_6_20_300_420_300_S$160_52 Physical Data Library Thu Jan 3 10:14:19
1991
FSW_35_20_150_420_150_A Physical Data Library Thu Jan 3 09:48:17 1991
FSW_35_20_150_420_150_S$160_52 Physical Data Library Thu Jan 3 09:48:17
1991
FSW_35_20_150_420_150_S$XS_52 Physical Data Library Thu Jan 3 09:48:20 1991
FSW_35_20_300_420_300_A Physical Data Library Thu Jan 3 09:48:41 1991
FSW_35_20_300_420_300_S$XS_52 Physical Data Library Thu Jan 3 09:49:04 1991
FWN_165_20_150_300_150_52 Physical Data Library Thu Jan 3 09:43:17 1991
FWN_165_20_150_300_A Physical Data Library Thu Jan 3 09:43:18 1991
FWN_254_20_150_300_150_52 Physical Data Library Thu Jan 3 09:44:57 1991
FWN_254_20_150_300_A Physical Data Library Thu Jan 3 09:44:57 1991
FWN_254_20_300_300_300_52 Physical Data Library Thu Jan 3 09:44:59 1991
FWN_254_20_300_300_A Physical Data Library Thu Jan 3 09:44:59 1991
FWN_35_20_150_300_150_52 Physical Data Library Thu Jan 3 09:48:13 1991
FWN_35_20_150_300_A Physical Data Library Thu Jan 3 09:48:16 1991
FWN_35_20_300_300_300_52 Physical Data Library Thu Jan 3 09:48:39 1991

Plant Design System (PDS) Reference Data Manager (PD_Data)

317

Table Checker
FWN_35_20_300_300_A Physical Data Library Thu Jan 3 09:48:41 1991
GATF_4625_420_800_A Physical Data Library Thu Jan 3 10:09:40 1991
GATF_FEM_800_3_A Physical Data Library Thu Jan 3 10:21:14 1991
GATR_4625_420_800_440_800_A Physical Data Library Thu Jan 3 10:09:39 1991
GATR_4625_420_800_A Physical Data Library Thu Jan 3 10:09:41 1991
GATR_FEM_800_3_A Physical Data Library Thu Jan 3 10:21:18 1991
GAT_40_20_150_A Physical Data Library Thu Jan 3 10:01:27 1991
GAT_40_20_300_A Physical Data Library Thu Jan 3 10:01:46 1991
GAT_BLT_150_3_A Physical Data Library Thu Jan 3 10:21:30 1991
GAT_BLT_300_3_A Physical Data Library Thu Jan 3 10:21:32 1991
GLOR_4625_420_800_A Physical Data Library Thu Jan 3 10:09:41 1991
GLOR_FEM_800_3_A Physical Data Library Thu Jan 3 10:21:42 1991
GLO_40_20_150_A Physical Data Library Thu Jan 3 10:01:28 1991
GLO_BLT_150_3_A Physical Data Library Thu Jan 3 10:21:52 1991
LOL_1575_300_S$STD_300_S$160_52 Physical Data Library Thu Jan 3 09:39:39
1991
LOL_1575_300_S$STD_300_S$160_A Physical Data Library Thu Jan 3 09:39:44
1991
MALWT_300_S$10_5_52 Physical Data Library Thu Jan 3 10:22:48 1991
MALWT_300_S$STD_5_52 Physical Data Library Thu Jan 3 10:23:07 1991
MALWT_300_S$XS_5_52 Physical Data Library Thu Jan 3 10:23:10 1991
MAL_300_5 Physical Data Library Thu Mar 21 15:55:49 1991
NEE_5375_420_800_A Physical Data Library Thu Jan 3 10:11:31 1991
NEE_FEM_800_3_A Physical Data Library Thu Jan 3 10:23:25 1991
NIP_100_300_S$160_52 Physical Data Library Thu Jan 3 09:27:27 1991
PLUG_41_300_A Physical Data Library Thu Jan 3 10:06:29 1991
PLUG_41_300_NREQD_52 Physical Data Library Thu Jan 3 10:06:37 1991
REDC_39_300_300_A Physical Data Library Thu Jan 3 09:52:38 1991
REDC_39_300_S$10_300_S$10_52 Physical Data Library Thu Jan 3 09:53:51 1991
REDC_39_300_S$10_300_S$STD_52 Physical Data Library Thu Jan 3 09:54:02 1991
REDC_39_300_S$STD_300_S$10_52 Physical Data Library Thu Jan 3 09:58:40 1991
REDC_39_300_S$STD_300_S$STD_52 Physical Data Library Thu Jan 3 09:58:52
1991
21-Apr-92 Page: 381
EDEN ACCESSED
_____________
EDEN Not Found EDEN Found
______________ __________
BALR
BALSP
BFYHP
BLPAD
BLSPA
BLSPC
BLSPO
CAPBV
CAPOT
CKLR
CKS
CKWF
CPL
E45
E45LR

318

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
E45TLR
E90
E90LR
E90SR
E90TLR
EOLLR
F10_1
F10_2
F122_1
F122_1_AMS
F13
F13_AMS
F173
F173_AMS
F177
F177_AMS
F178
F178_AMS
F179
F17D
F17D_AMS
F180
F180_AMS
F182
F182_AMS
F188
F188_AMS
F19
F19_AMS
F1A
F1A_AMS
F25
F25_AMS
F27
F27_AMS
F28
F39
F39_AMS
F47
F47T_AMS
F47_AMS
F6
F6_AMS
F8
F8_AMS
21-Apr-92 Page: 382
EDEN ACCESSED
_____________
EDEN Not Found EDEN Found
______________ __________
FBLD
FITTING_1_AMS

Plant Design System (PDS) Reference Data Manager (PD_Data)

319

Table Checker
FITTING_2_AMS
FITTING_3_AMS
FLANGE_AMS
FOLHC
FOWNAW
FRSW
FSW
FWN
GAT
GATF
GATR
GLO
GLOR
LOL
NEE
NIP
OLET_1_AMS
OP3
OP9
OPERATOR_3
OPERATOR_33
OPERATOR_9
OP_17
OP_3
OP_33
OP_331
OP_332
OP_9
PIPING
PLUG
REDC
REDE
RPAD
RWELD
SOL
SWGC
SWGE
T
TRB
UN
V1
V11
V1_AMS
V26
V38
V6
VALVE_2_AMS
WOL
.*****. REPORT ERROR LOG CREATION TIME: Tuesday 04/21/92 15:35
1 - ERROR - EDEN error (-3) for pmc 1C0031 item 6Q1C26 with 1st size
32IN and 2nd size 32IN
Error in module MGOP_32768

320

Plant Design System (PDS) Reference Data Manager (PD_Data)

Table Checker
2 - ERROR - EDEN error (-3) for pmc 1C0031 item 6Q1C26 with 1st size
34IN and 2nd size 34IN
Error in module MGOP_32768

Error Codes
The following error codes are used in the reported error messages.
-3 Eden Module Not Found
-4 Entry Not Found in Table
-7 Table Not Found

Plant Design System (PDS) Reference Data Manager (PD_Data)

321

SECTION 12

Pipe Support Tutorial Definition Manager


The Pipe Support Tutorial Definition Manager provides access to the Tutorial Definition Files
(TDFs) used in placing pipe supports in the model. The TDFs define the pipe support's modeling
requirements.
For more information on TDFs, refer to the Pipe Supports Modeler Reference Guide.

Support Tutorial Definition Manager


The Support Tutorial Definition Manager is used to create a new Tutorial Definition Library or to
create, modify, or delete data in the library. You can also create reports of the data in the library.
Select the Support Tutorial Definition Manager from the Reference Data Manager form.

Before Using This Command

Define the location of the approved and unapproved (if applicable) Pipe Support Tutorial
Definition Library files in the Reference Database Management Data.
You must have write access to the specified file and directory path.

Options

Create Library (on page 324) Used to create a new Tutorial Definition Library.
Compress Library (see "Compress" on page 324) Used to compress the Tutorial Definition
Library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

323

Pipe Support Tutorial Definition Manager

Unapproved ==> Approved (on page 324) Used to copy the unapproved Tutorial Definition
Library to the approved library.
Create Data (on page 324) Used to compile source files and add the resulting code to the
Tutorial Definition Library. You can create a single tutorial definition file or specify a list of
tutorial definition files to be created.
Revise Data (on page 325) Used to select a tutorial definition file from the library for editing
and compile the revised tutorial definition file.
Delete Data (on page 326) Used to delete a specified tutorial definition file from the library.
Report Data (on page 327) Used to create a report file of the library contents.
List Data (on page 328) Used to list the files contained in the library.
Extract Data (on page 329) Used to extract a tutorial definition file from the library for editing
or printing.
Full List/Sub-string Use this toggle to determine the data to be listed. Full List returns all
the definition in the Tutorial Definition Library. Sub-string limits the list to those files that
contain the substring you enter in the corresponding box.
Node Name Key in the node name of the location of the table definition files for pipe
supports.
File Path Key in the path to the location where you store table definition files for pipe
supports.

Create Library
This option is used to create a new Tutorial Definition Library.
The system displays the approved and unapproved Tutorial Definition Library names as defined in
the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Compress
This option is used to compress the Pipe Support Tutorial Definition Library. Any tables which
have been deleted from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Pipe Support Tutorial Definition Library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

Create Data
This option enables you to create a new tutorial definition file. You can process a single file or
specify a list of files to be created.

Operating Sequence
1. Select the Create Data option.

324

Plant Design System (PDS) Reference Data Manager (PD_Data)

Pipe Support Tutorial Definition Manager

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
Key in the name of the source file or list file to be compiled and added to the active library.

The system displays the default node name and path for the tutorial definition files as
specified in the Default Project Control Data at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
4. Accept or Select Other Option
Accept the file to begin processing.
If a fatal error occurs while loading files, the Tutorial Definition File Library is left unchanged.

Revise Data
This option enables you to replace an existing tutorial definition file. This option enables you to
select a tutorial definition file from the library, edit the file, and then compile the file and put it back
in the library.

Operating Sequence
1. Select the Revise option.

The system displays the tutorial definition files in the Tutorial Definition Library.

2. Select Table for Revision


Select the tutorial definition files to be revised and select Accept.

The system extracts the specified file from the library and activates the text editor to enable

Plant Design System (PDS) Reference Data Manager (PD_Data)

325

Pipe Support Tutorial Definition Manager


you to modify the file.
3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library. (If you quit the text editor, the file is not recompiled.)

Delete Data
This option enables you to delete a tutorial definition file from the Tutorial Definition Library.

Operating Sequence
1. Select the Delete option.

326

Plant Design System (PDS) Reference Data Manager (PD_Data)

Pipe Support Tutorial Definition Manager


The system displays the tutorial definition files in the Tutorial Definition Library.

2. Select Table for Deletion


Select the tutorial definition file to be deleted from the list of files. You can use the scroll bar
to scroll through the available files.
3. Accept or Select Other Table(s)
Accept the selected tutorial definition file.

The system deletes the tutorial definition file from the Tutorial Definition Library.

Report Data
This option enables you to create a report on the contents of the Tutorial Definition Library. This
report lists all the tutorial definition files in the Tutorial Definition Library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

327

Pipe Support Tutorial Definition Manager


Operating Sequence
1. Select the Report Data option from the Library/Data Management form.

2. Set the toggle to Report on Unapproved or Report on Approved to define the source of
information to be reported. This toggle is only displayed when both the approved and the
unapproved library are being used.
3. Select the report option: Save, Print/Delete, or Print/Save.

For the Print/Delete or Print/Save options, select the print queue from the list of displayed
queues.
4. Select Accept to create the report.

For the Save or Print/Save options, the system generates a report named ppsm_tdf in the
default directory based on the contents of the Pipe Support Tutorial Definition Library.

List Data
This option displays all the tutorial definition files for the Tutorial Definition Library.

328

Plant Design System (PDS) Reference Data Manager (PD_Data)

Pipe Support Tutorial Definition Manager


Operating Sequence
1. Select the List option.

The system displays the tutorial definition files in the Tutorial Definition Library.

2. You can use the scroll bar to scroll through the available files.
3. Select Cancel to exit the form.

Extract Data
This option enables you to extract a tutorial definition file from the Tutorial Definition Library for
editing or printing.

Operating Sequence
1. Select Extract Data from the Library/Data Management form.

Plant Design System (PDS) Reference Data Manager (PD_Data)

329

Pipe Support Tutorial Definition Manager

2. Select Table for Extraction


Select the tutorial definition file from the list of files and select Accept. You can use the scroll
bar to scroll through the available files.
OR
Select the Extract All button to extract all the available files.

The system pulls the file out of the library and places it in the default directory defined in the
Default Project Control Data. See Default Project Control Data (on page 35).

Library List
The Library List form allows you to select database tables in order to revise, delete, list or extract
the tables.

Operating Sequence
1. Select Table.
Select a table to manipulate.
2. Accept or Select Other Table(s).
Select more tables to manipulate.
OR
Select Accept to continue the workflow.
OR
Select Cancel to exit the form.

330

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 13

Standard Note Library


The Standard Note Library contains the code list text for code-listed attributes, including standard
notes. It enables you to define standard text required to support the piping design effort.
The standard code list text is delivered in the file \win32app\ingr\pdshell\lib\std_note.l. The
accompanying source listing for this file is contained in the file std_note.l.t. You can add, delete, or
revise code list sets in the library to reflect your own practices, terminology, and language.
Entries in these files are in the form Standard Note Type xxxx where xxxx is the number of the
code list set.
Refer to Appendix: Codelists (on page 423) for a listing of the delivered Standard Note Library.

Neutral File Description


A neutral file is an ASCII text file which contains standard notes or code lists to be placed in the
Standard Note Library. An entry is a single input/output record. One entry (or word) is retrieved
each time a neutral file is read. The entries in a neutral file must be separated by at least one
space. If an embedded blank is contained within an entry, the entire entry must be enclosed in
single quotes (').
2 = 'Hydrogen Gas'
Entries enclosed in single quotes can take up more than one line. When an entry continues onto
a new line, a blank character is automatically appended to the end of the previous line.

Neutral File Format


N499
;

Piping Notes
1 = ' '

;
;

Notes Applicable to the Piping Materials Class, 2-199


WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
;

Plant Design System (PDS) Reference Data Manager (PD_Data)

331

Standard Note Library


;

Notes Applicable to a Piping Component, 200-499


WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
;
;
Notes Applicable to a Piping Specialty, 500-699
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'
;
;
Notes Applicable to an Instrument Specialty, 700-899
WWW =
'ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ'

General Rules

332

EACH standard note type or code list type should be contained in a separate neutral file.
Neutral files should have the following basic format:
C125
DF='WRK_DD_CODLST:CODE0125.ENT' MAX=999
; This is a comment line !!!!!!
; This file contains a code list for type 125.
0125, Fluid Code/Connector Type (999)
NOTE: In editing this codelist set, do not change the meaning
of existing codelist values 950-999.
1 = ' '
6 = 'Standard note or code list descriptions can extend
beyond one line of text up to a maximum of 80 characters'
11 = 'A'
14 = 'AC'

Plant Design System (PDS) Reference Data Manager (PD_Data)

Standard Note Library


17 = 'AE'

The first entry in each neutral file should be the note/code TYPE (C125 in the above example).
The first letter must be either: C for a codelist set or N for a standard note.
This character is followed by a number, which identifies the specific codelist set or standard
note. This number must be a valid short integer.
This entry should also include the text used for extracting information from the Standard Note
Library. This text may contain up to 80 characters.
The first line should also contain the maximum number of entries for the codelist or standard
note.
The following numbering conventions are used for standard note type 499:

Piping Job Specification: note numbers 1 through 199.

Piping Commodity Item: note numbers 200 through 599.

Specialty Item: note numbers 600 through 799.

Instrument Item: note numbers 800 through 999.


You can include the keyword PID_RDB in the neutral file on the line following the standard
note type to load the standard note into both the Piping Reference Database and the P&ID
Reference Database simultaneously. (Optional)
Each note/code entry is comprised of three parts (triplet) which must appear in the following
sequence.
<Note/Code number> <equal sign> <Note/code description>
2 = 'Sulfuric Acid'

The description text must be enclosed in single quotes.

The description text can extend for more than one line.

Code list description text can contain up to 80 characters.

Standard note description text can contain up to 400 characters.

The Note/code description text can be on a line by itself.

The equal sign must have a blank character on either side of it.

The equal sign can be on a separate line by itself.

The note/code number must be a valid I*2 integer.

The note/code number must begin a new line; it cannot be on the same line with any part
of another triplet.

The note/code number can be on a line by itself.


The only valid edit you can make to code list 1056 (temperature units) and code list 1064
(pressure units) is to modify the displayed text string. Modifications to this field affect only the
display of the text; the actual units (for example, degrees) cannot be modified. You cannot
add any entries to code lists 1056 and 1064.
Comments are indicated with a semicolon (;) or exclamation point (!). Any information on a line
to the right of either of these characters is considered a comment and is ignored. These
comment lines can only occur following a description; they cannot break up a triplet.
Valid Comments
1 = 'Caustic'
;
Comment line.
2 = 'Sulfur' ! Another Comment line.
!
Another Comment line.
3 = 'Hydrogen Sulfide' ; Another Comment line.

Plant Design System (PDS) Reference Data Manager (PD_Data)

333

Standard Note Library


Invalid Comments
;

1 =
Invalid Comment line.
'Caustic'
2 = ! Invalid Comment line. 'Sulfur'

Any text enclosed in < angle brackets > is considered a comment and is ignored. These
comments can appear anywhere in the neutral file except within a description.
Blank lines can occur anywhere in a neutral files for readability. These lines are ignored.
Each entry can begin at any point along an input line but must be separated from adjacent
entries by one or more spaces.
Note/code numbers need not be in sequential order.

Defining Text for Standard Note Types


You can specify the text for the various standard note types by loading the standard note titles as
standard note type 999. The specified title will display in a list of standard note types or a list of
the selections for a specific standard note type.

Standard Note Library Manager


The Standard Note Library Manager is used to create a new Standard Note Library (on page
331) or to create, modify, or delete data in the library. You can also create reports of the data in
the library. Select the Standard Note Library Manager from the Reference Data Manager form.

Before Using This Command

334

Define the location of the approved and unapproved (if applicable) Standard Note Library files
in the Reference Database Management Data.
You must have write access to the specified file and directory path.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Standard Note Library


Options

Create Library (on page 335) Used to create a new Standard Note Library.
Compress Library (see "Compress" on page 335) Used to compress the Standard Note
Library.
Unapproved ==> Approved (on page 335) Used to copy the unapproved Standard Note
Library to the approved library.
Create (see "Create Standard Note Type" on page 336) Used to compile source files and
add the resulting code to the Standard Note Library. You can create a single standard note
set or specify a list of standard notes to be created.
Revise (see "Revise Standard Note Type" on page 336) Used to select a standard note set
from the library for editing and compile the revised standard note definition.
Report (see "Report Standard Note Library Contents" on page 338) Used to create a report
file of the library contents.
List (see "List Standard Note Data" on page 339) Used to list the files contained in the
library.
Delete (see "Delete Standard Note Data" on page 339) Used to delete a specified standard
note set from the library.
Extract (see "Extract Standard Note Type" on page 340) Used to extract a standard note
set from the library for editing or printing.
Load Database (on page 341) Used to load the contents of the Standard Note Library into
the applicable schemas of the project's relational database to support DBAccess reporting of
PDS data.

Create Library
This option is used to create a new Standard Note Library. It automatically creates the object
library (.l) and the text library (.l.t) for the library that is being created.
The system displays the approved and unapproved Standard Note Library names as defined in
the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Compress
This option is used to compress the Standard Note Library. Any tables which have been deleted
from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Standard Note Library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

335

Standard Note Library

Create Standard Note Type


This option enables you to create a new standard note set by inserting the data in a neutral file into
the Standard Note Library. The neutral file enables you to define piping notes required to support
the piping design effort. You can define code list sets, or standard notes applicable to a piping
materials class, a piping commodity, a specialty item, or an instrument. You can process a single
file or specify a list of files to be created.

Before Using This Command


To add more than one standard note type to the library, create a list file which identifies the names
of the standard note source files to be added. The list file should contain one entry (source file
name) per line.
You can define the default path for standard note neutral files using the Default Project Control
Data option. See Default Project Control Data (on page 35).

Operating Sequence
1. Select the Create option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for processing
Key in the name of the source file or list file to be compiled and added to the active library.

The system displays the default node name and path for the standard note neutral files as
specified in the Default Project Control Data at the bottom of the form.
You can use the default setting or modify these fields to override the default location for this
operation.
4. Accept or Select Other Option
Accept the file to begin processing.
If a fatal error occurs while loading neutral files, the Standard Note Library is left unchanged.

Revise Standard Note Type


This option enables you to replace an existing standard note type. This option enables you to
select a standard note type from the library, edit the file, and then compile the file and put it back in
the library.

Operating Sequence
1. Select the Revise option.

336

Plant Design System (PDS) Reference Data Manager (PD_Data)

Standard Note Library


The system displays the standard note types in the Standard Note Library.

2. Select Module Name


Select the standard note types to be revised and select Accept.

Plant Design System (PDS) Reference Data Manager (PD_Data)

337

Standard Note Library


The system extracts the specified file from the library and activates the text editor (specified
for PD_EDITOR in the control.sh file) to enable you to modify the file.

3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library. (If you quit the text editor, the file is not recompiled.)

Report Standard Note Library Contents


This option enables you to create a report on the contents of the Standard Note Library. This
report list all the standard note types in the Standard Note Library.
Refer to Appendix: Codelists (on page 423) for a listing of the report file for the delivered Standard
Note Library. - Not sure where this appendix is.

Operating Sequence
1. Select the Report option from the Data Management form.
2. Set the toggle to Report on Unapproved or Report on Approved to define the source of
information to be reported. This toggle is only displayed when both the approved and the
unapproved library are being used.
3. Select the report option: Save, Print/Delete, or Print/Save.
For the Print/Delete or Print/Save options, select the print queue from the list of displayed
queues.
4. Select Accept to create the report.

For the Save or Print/Save options, the system generates a report named stnotelib.rpt in the

338

Plant Design System (PDS) Reference Data Manager (PD_Data)

Standard Note Library


default directory based on the contents of the Standard Note Library.

List Standard Note Data


This option displays all the standard note types for the Standard Note Library.

Operating Sequence
1. Select the List option.

The system displays the Standard note types in the Standard Note Library.

2. You can use the scroll bar to scroll through the available files.
3. Select Cancel to exit the form.

Delete Standard Note Data


This option enables you to delete a Standard note type from the Standard Note Library.

Operating Sequence
1. Select the Delete option.

The system displays the Standard note types in the Standard Note Library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

339

Standard Note Library

2. Select Note Type


Select the Standard note type to be deleted from the list of note types. You can use the scroll
bar to scroll through the available files.
3. Accept or Select Other Note Type
Accept the selected standard note type.

The system deletes the standard note type from the Standard Note Library.

Extract Standard Note Type


This option enables you to extract a neutral file from the Standard Note Library for editing or
printing.

340

Plant Design System (PDS) Reference Data Manager (PD_Data)

Standard Note Library


Operating Sequence
1. Select Extract from the Data Management form.

2. Select Note Type


Select the standard note type from the list of files and select Accept. You can use the scroll
bar to scroll through the available files.

The system pulls the file out of the library and places it in the default directory defined in the
Default Project Control Data. See Default Project Control Data (on page 35).

Load Database
This option loads the contents of the Standard Note Library into the applicable schemas of the
project's relational database to support DBAccess reporting of PDS data.

Before Using This Command


You must create the necessary database structure for DBAcess reporting through the Project
Administrator. Refer to the description of the Project Setup Manager in the Project
Administrator (PD_Project) User's Guide for more information.
You must specify the maximum length of the text for each standard note type in the Standard Note
Library in an ASCII file named stnote_max_len. This maximum length is used to load the
standard note data in the relational database. This is the same file used in the Project
Administrator to modify the database structure to support DBAccess. It must reside in the
project directory.
Entries in this file consist of one line for each standard note type with the following format.
!note type max length short?
35
15
*
36
10

Plant Design System (PDS) Reference Data Manager (PD_Data)

341

Standard Note Library


The note type and the maximum length are separated by one or more spaces or tabs. An
asterisk (*) following the maximum length indicates that the short version of the standard note data
be loaded into the relational database. The default is that the long version be loaded.
Comments can be placed anywhere in the file and must be preceded by an exclamation point (!).
You can determine which standard note data is loaded or not loaded into the relational database.
If the maximum length for a standard note type is defined as zero (0) or the standard note type is
not included in stnote_max_len, the data for that standard note type will not be loaded.
Standard notes loaded into the schema are listed below.
In DD_SCHEMA, the following codelists required by designing purposes are loaded:
design_cls[36]={35,
35,50,69,125,130,145,160,180,190,200,210,220,230,330,340,360,365,380,390,400,420,42
5,430,499, 570,575,576,577,578,1010,1028,1056,1064,1074,1100};
In PD_SCHEMA, the following codelist tables required at the project level are loaded:
project_cls[17]={16,
35,499,1202,1203,1204,1205,1207,1310,1312,1410,1610,1620,1630,1710,1720,2000};
In RU/RA_SCHEMA, the following codelist tables required at the database level are loaded:
reference_cls [12] = {11,125,145,148,180,330,400,499,575,576,577,578};
A default note length file is delivered with the PD_Shell product in the file
\win32app\ingr\pdshell\lib\stnote_max_len. These maximum lengths were determined on the
basis of the long option of standard note data reporting. To minimize relational database size,
you should exercise discretion in specifying the maximum length. The maximum length for any
standard note type is restricted to 240 characters by RIS.

Operating Sequence
1. Select Load Database from the Data Management form.
2. Select Submit to Batch Immediately to begin processing as soon as you exit the form.
OR
Select Delayed Submit to Batch to specify a day and time to process the request.
3. Accept the specified time.

The system submits the request to the batch queue PDreference.

Standard Note Types List


This form allows you to select a Standard Note Type from the library in order to revise, list, delete,
or extract the type.
For more information, see Revise Standard Note Type (on page 336), List Standard Note Data (on
page 339), Delete Standard Note Data (on page 339), and Extract Standard Note Type (on page
340).

342

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 14

Label Description Library


The Label Description Library contains the definitions for the following basic types of labels. (The
numbers in parentheses indicate the range of label numbers for each group of label types.) Refer
to Label Types (on page 343) for more information.
Drawing View Specific Labels (1-129, 2500-2599)
System Reserved Labels (1-29)
User Defined Piping/Equipment Labels (30-49)
User Defined Structural Labels (70-89)
User Defined Miscellaneous Labels (90-109)
User Defined Electrical Raceway Labels (110-129)
User Defined PLANTGEN Labels (2500-2599)
Drawing View Identification Labels (50-69)
User Input Labels (200-219)
Displayable Attribute Labels (300-399)
Commodity Code Labels (400-899)
U.S. practice (400-449)
European - DIN (450-499)
European - British Standard (500-549)
European A - Finnish, French, etc. (550-599)
European B - (750-799)
International - JIS (600-649)
International - Australian (650-699)
International A (800-849)
International B (850-899)
Company practice (700-749)
Isometric Drawing Labels (900-999)
Report Labels (1150-2149)
Clash Management Labels (2200- 2399)
These labels are intelligent graphics which represent information from the non-graphical data
(databases, user data, etc.). You can update existing drawing view specific labels (1-49, 70-130)
to reflect the latest data in the database.
The default label description library is delivered in the file \win32app\ingr\pdshell\lib\labels.l. All
changes to the library are performed interactively using the Label Description Library Manager (on
page 347).

Label Types
Displayable Attribute Labels (on page 344)
Alphanumeric Labels (on page 344)
Displayable Attribute Message (on page 344)

Plant Design System (PDS) Reference Data Manager (PD_Data)

343

Label Description Library


Commodity Code Attribute Message (on page 345)
Isometric Drawing Labels (on page 345)
Report Labels (on page 345)
Clash Management Labels (on page 345)

Displayable Attribute Labels


Each type of displayable attribute label has a description in the Label Description Library. This
description identifies the label characteristics such as level, color code, style, and font, and the
attribute data associated with the label.
A displayable attribute label consists of the text and optionally, a leader line, a line terminator, and
some label enclosure graphics. There are four sub-types of Displayable Attribute Labels:
Drawing View Specific Label
displayable attribute labels for named model items which are placed in a drawing.
Drawing View Identification Label
labels with attribute linkages to the Drawing View Data (table 122) that report information
about the drawing view such as drawing view name and view scale
Drawing View Specific Labels are further divided into subcategories for Piping, Structural, HVAC,
and Raceway. Drawing View Specific Labels for Piping and View Independent Labels are
divided into sub-ranges for system-defined labels and user labels.
PDS delivers Design Review Labels (317-330). These labels are the only ones
processed by PDS Design Review. You can create new Design Review labels, but the system
will not access them.

Alphanumeric Labels
Alphanumeric labels are non-intelligent user-defined labels. Each type of alphanumeric label has
a description in the Label Description Library. This description identifies the label characteristics
such as level, color code, style, and font. An alphanumeric label consists of the text and optionally,
a leader line, a line terminator, and some label enclosure graphics.

Displayable Attribute Message


Each type of displayable attribute message has a description in the Label Description Library.
Unlike the other label types, the description of a displayable attribute message only contains the
attribute data. Therefore, you cannot define label description data such as color, weight, style,
and text size for a displayable attribute message.
A displayable attribute message has all or part of its text derived from the alphanumeric data that
is linked to a specified named item in the model.
A displayable attribute message is displayed temporarily at the terminal either as an identification
message or as a reporting message. Some of these messages are displayed in the terminal's
refresh message fields. Other messages are displayed temporarily in the model. The system
does not place any graphics in the model for this type of label. The text size of these labels is
always the same regardless of the screen view scale.
A displayable attribute message can also be used to create a value for another attribute, for
example, the Line Number Label attribute.
Displayable attribute messages also define the hard-coded values for Design Review labels.

344

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

Commodity Code Attribute Message


Commodity code attribute messages are the same as displayable attribute messages, except they
are used for bill of materials reporting. All or part of the messages text is derived from the
alphanumeric data in the database. A material description attribute message only contains
attribute data; you cannot define label description data such as color, weight, style, and text size.
There are 10 categories of commodity code attribute messages:
U.S. practice
DIN practice
British Standard
European practice A
European practice B
International practice - JIS
International practice - Australian
International practice A
International practice B
Company practice

Isometric Drawing Labels


The isometric drawing labels are similar to the commodity code attribute messages and are used
by the isometric extraction software.

Report Labels
A range of report labels (1150-2149) is reserved in the Label Description Library for use in
formatting fields in a report. This is accomplished by using the special report indices for the Label
Description Library. (Refer to the Report Manager Reference Guide for information on the report
indices.)
When report labels are used, you cannot sort on an individual attribute used to form the
report label. However, you can sort on the complete report label.

Clash Management Labels


A range of labels (2200-2299) is reserved in the Label Description Library for use by the Envelope
Builder in creating the primary description and the secondary description for clash management.
The label to be used is determined on the basis of the model's discipline and the type of
component. The following label numbers are reserved in the Label Description Library for use in
clash management.
Envelope builders for disciplines other than piping and equipment do not implement the
labels reserved below.
2200 Piping - primary description for piping specialty - 2 cp's
2201 Piping - primary description for piping specialty - 3 cp's
2202 Piping - primary description for piping commodity - 2 cp's
2203 Piping - primary description for piping commodity - 3 cp's
2204 Piping - primary description for piping/tubing
2205 Piping - primary description for instrument component - 2 cp's
2206 Piping - primary description for instrument component - 3 cp's
2207 Piping - primary description for pipe support

Plant Design System (PDS) Reference Data Manager (PD_Data)

345

Label Description Library


2208 Piping - secondary description for piping segment
2220 Equipment - primary description for equipment
2221 Equipment - primary description for nozzle
2222 Equipment - secondary description for equipment
2223 Equipment - secondary description for nozzle
2240 PLANTGEN - pipe
2241 PLANTGEN - piping component
2242 PLANTGEN - equipment/miscellaneous
2243 PLANTGEN - nozzle
2244 PLANTGEN - structural/civil
2245 PLANTGEN - HVAC
2246 PLANTGEN - raceway
2247 PLANTGEN - pipe support
2260 Raceway - Straight Primary Label
2262 Raceway - Straight Secondary Label
2261 Raceway - Fitting Primary Label
2263 Raceway - Fitting Secondary Label
2264 Raceway - Panel Primary Label
2265 Raceway - Panel Secondary Label
2266 Raceway - Ductbank Primary Label
2267 Raceway - Ductbank Secondary Label
2280 HVAC - Primary Label for Connector
2281 HVAC - Secondary Label for Connector
2282 HVAC - Primary Label for Fitting
2283 HVAC - Secondary Label for Fitting
2284 HVAC - Primary Label for Duct
2285 HVAC - Secondary Label for Duct
2286 HVAC - Primary Label for Diffuser
2287 HVAC - Secondary Label for Diffuser
2288 HVAC - Primary Label for Grille
2289 HVAC - Secondary Label for Grille
2290 HVAC - Primary Label for Register
2291 HVAC - Secondary Label for Register
2292 HVAC - Primary Label for Humidifier
2293 HVAC - Secondary Label for Humidifier
2294 HVAC - Primary Label for Filter
2295 HVAC - Secondary Label for Filter
2296 HVAC - Primary Label for Damper
2297 HVAC - Secondary Label for Damper
2298 HVAC - Primary Label for Coil
2299 HVAC - Secondary Label for Coil
2300 HVAC - Primary Label for Terminal Device
2301 HVAC - Secondary Label for Terminal Device
2302 HVAC - Primary Label for Equipment
2303 HVAC - Secondary Label for Equipment
2304 HVAC - Primary Label for Hood
2305 HVAC - Secondary Label for Hood
The 2 CP clash management labels are used when the number of connect points, excluding taps,
is less than or equal to two. The 3 CP clash management labels are used when the number of
connect points, excluding taps, is greater than or equal to three.
The primary description is limited to 20 characters, and the secondary description is limited to 40
characters.

346

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

Label Description Library Manager


The Label Description Library Manager enables you to define the graphic parameters for a
label (such as level, line weight, and color code) and to define the format of the label (what
information comprises the label). You can create a new (empty) label description library or
create, revise, or delete label descriptions in an existing library.

Create Library (on page 347) Used to create a new Label Description Library.
Compress Library (on page 348) Used to compress the Label Description library.
Unapproved ==> Approved (on page 348) Used to copy the unapproved Label Description
library to the approved library.
Create Label Data (on page 348) Used to create a new label description and insert it in the
Label Description Library.
Revise Label Data (on page 358) Used to select a label from the library, edit the file, and put
the revised file back into the library.
Delete Label Data (on page 361) Used to remove a label description from the library.
Report Label Data (on page 361) Used to create a report of the library contents.

Create Library
This option is used to create a new Label Description Library. This option will be deactivated if
the specified library already exists.
The system displays the approved and unapproved Label Description Library names as defined in
the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library file. If you specify an existing library file, the system
displays an error indicating the library already exists.

Plant Design System (PDS) Reference Data Manager (PD_Data)

347

Label Description Library

Compress Library
This option is used to compress the Label Description library. Any labels which have been
deleted from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Label Description library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

Create Label Data


This option enables you to add a label description of a specified type to the Label description
Library.

Operating Sequence
1. Select Create Label Data from the Data Management form.

The system displays a form listing the types of labels which can be created.

2. Select Option
Select the type of label to be created. See Label Types (on page 343) for a description of all
the label types and subtypes.

The system adds a label number in the range for the selected label type, and activates one of
the following screens to enable you to define the description data and/or attribute data for the
label to be created.

348

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

For Drawing View Specific Labels and Drawing View Identification Labels, you can
define both graphic data and attribute data.
For User Input Labels, you can define graphic data only. Refer to Create Label Graphic
Data (on page 351) for more information.
For Isometric Drawing Labels, Displayable Attribute Labels, Commodity Code
Labels, Report Labels, or Clash Management, you can define attribute data only. Refer
to Create Label Attribute Data (on page 353) for more information.

Label Subtypes
Depending on the Option selected, the system may activate one of the following basic types of
labels to further classify the type of label to be created. (The numbers in parentheses indicate the
range of label numbers for each group of label types.)
Orthographic Drawing View Specific Labels

System Reserved Labels (1-29)


User Defined Piping/Equipment Labels (30-49)
User Defined Structural Labels (70-89)
User Defined Miscellaneous Labels (90-109)
User Defined Electrical Raceway Labels (110-129)
User Defined PLANTGEN Labels (2500-2599)

Plant Design System (PDS) Reference Data Manager (PD_Data)

349

Label Description Library

Commodity Code Labels

U.S. practice (400-499)


DIN practice (450-499)
British Standard (500-549)
European practice 'A' (550-599)
European practice 'B' (750-799)
International practice - JIS (600-649)
International practice - Australian (650-690)
International practice 'A' (800-849)
International practice 'B' (850-899)
Company practice (700-749)

350

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

Create Label Graphic Data


This form enables you to define the graphic parameters for the selected label type.

Create Label Attribute Data (on page 353) Enables you to specify the attributes which make
up the label and the format of the label.
Mass Annotation Options (on page 358) Enables you to set up the Mass Annotation options
for use with PD_Draw.

Field Descriptions

Label Type Number of the label being created. (This field is filled in automatically by the
system.)
Label Description Short description for the label (up to 20 characters).
Graphics Color Activates the Select Color form used to set the color for the label
enclosure, leader line, and line terminator.
Graphics Weight Line weight (0-31) for the label enclosure, leader line, and line
terminator.
Graphics Style Line Style (0-7) for the label enclosure, leader line, and line terminator.
Alternate Style Alternate (centerline) line style (0-7) for name label leader lines. The
default is the same as the Graphics Style.
Text Color Activates the Select Color form used to set the color for the label text.
Text Weight Line weight (0-31) for the label text.
Character Size Activates the Define Active Character Size form used to set the character
plot size (text height and text width). You can select one of the default settings (A - J) or key
in a size. The default settings are defined in the drawing's type 63 data. Refer to the Project
Data Manager in the Project Administrator Reference Guide for information on setting the
default sizes.

Plant Design System (PDS) Reference Data Manager (PD_Data)

351

Label Description Library

Maximum Length Maximum line length (1-80) for the text. This setting is also used to
determine the label enclosure size.
Line Spacing Line spacing between label text represented as a fraction of text height (0. 10.). Also used to determine label enclosure size.
Maximum Lines Maximum number of lines in the label text (1-30). Also used to
determine label enclosure size.
Text Font Font (0-255) for the label text.
Enclosure Option Displays a set of options at the bottom of the form for setting the type of
label enclosure. The default is No Label Enclosure.

The User Defined Enclosure Option places as a cell, with no Leader Line. When this
option is chosen, the Leader Line Option toggle is no longer available.
Diameter (Used with Label Enclosure Options 2 and 3) Diameter of the circle enclosure
graphic.
Cell Name (Used with Label Enclosure Option 8) Name of the Label Enclosure cell.
Leader Line Option Toggle to define whether to use a Leader Line for the label.
Terminator Char. Character that represents the line terminator symbol in the attached
Font Library.
Terminator Font Font (0-255) for the line terminator.
Underline Spacing Underline spacing below text represented as a fraction of text height
(0. - 10.). If this value is 0, no underlining is performed.
Label Category The form displays the name label category and the user-defined drawing
annotation categories. You can select one of the 20 user-defined drawing annotation
categories or use the default category. The default category is that of the name label
category. The text for the drawing annotation categories is extracted from the drawing
category descriptions (drwcats.txt) in the project directory.
All of these parameters do not apply to each label type; the system skips over any non-required
parameters.
Once you have defined all the applicable parameters, select Attribute Label Data to specify the
attributes which make up the label and the format of the label (or select Accept for graphics only
labels). If your project will be using the Mass Annotation command in PD_Draw to simplify label
placement, select the Mass Annotation Options command to set up the Mass Annotation
options. Refer to Mass Annotation Options (on page 358) for more details.

352

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

Create Label Attribute Data


This form enables you to specify the attributes which make up the label and the format of the label.
The Line and Item fields are used to define the attributes that make up the label and the order of
the attributes within the label.

Set the option at the upper left of the form.


Insert Data

Used to add a line or item to the label description.

Delete Data

Used to delete a selected line or item from the label


description.

Edit Data

Used to revise a selected line or item in the label description.

Insert Data
1. Set the option to Insert Data.
2. Set the toggle to Insert after or Insert before.
3. Select Line or Item to Insert Data
Select a line field to create a new line (before or after) the selected line.
OR
Select an item field to create a new item in the current line (before or after) the selected item.

The system activates a form that displays the Attribute Data Types. The following forms
illustrates the displays for a drawing view specific label. (The second form appears when
Other Data is selected.)

Plant Design System (PDS) Reference Data Manager (PD_Data)

353

Label Description Library

4. Select Option
Select the attribute data type for the label.
You can select Other Data to select the attribute data type for Raceway data.

354

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


The system displays the attributes for the selected data type.

5. Enter Data
Select the attribute to be reported from the form. The system sets the Format Data
automatically. You can modify the total length and the number of decimal places (if
applicable).
For labels that include an angle value (such as the bend angle of a piping component), select
the Angle format to display the value in angle units (such as degrees and minutes). The
angle units are determined by the angular format defined through the Project Data Manager.
For labels that include a distance attribute (such as the face-to-face dimension of a piping
component), you can select Fraction to format decimal attributes as a coordinate readout.
This option is restricted to those decimal attributes that represent dimensions.
OR
For drawing view specific labels, you can select User Keyin Attribute to specify text to be
entered by the user at label creation.
OR
Select Text Only and key in the text for a literal expression to be inserted in the label.
OR
Select Spacing Only and key in the number of spaces to define spacing between attributes.
6. Repeat the previous step to add additional attribute text information. This allows you to
combine attribute values and pre-formatted text.
You can only define one user-defined keyin in a specific label.
7. Select one of the Optional Data options to specify a modifier to the active format.
Master Units = MicroStation master units, Sub Units = MicroStation sub units.
8. Accept the specified attribute data.

Delete Data
1. Set the option to Delete Data.

Plant Design System (PDS) Reference Data Manager (PD_Data)

355

Label Description Library


2. Select the line or item to be deleted.
3. Select Accept to delete the highlighted line or item. When you select a line, the system
deletes all the associated items.

Edit Data
1. Set the option to Edit Data.
2. Select Item to Edit
Select the item to be revised.

The system displays the attributes definition form for the selected item. The active setting is
highlighted or shown in the display fields.
3. Select an attribute from the form to change the type of data.
OR
Select the Format Data option. You can modify the total length and the number of decimal
places (if applicable).
OR
For drawing view specific labels, you can select User Keyin Attribute to specify text to be
entered by the user at label creation.
OR
Select Text Only and key in the text for a literal expression to be inserted in the label.
OR
Select Spacing Only and key in the number of spaces to define spacing between attributes.
4. Repeat the previous steps to edit additional items.
THEN
Accept the edits.

Examples
**************** Label Type = 310 ****************
Label Name = Line Number Label
[1][2][3]-[5]-[7]-[9]
Piping Segment Data
[1] fluid_code
- Character (3)
[2] unit_code
- Character (2)
[3] line_sequence_no
- Character (16)
4
- '-'
[5] nominal_piping_dia - Character (7)
6
- '-'
[7] piping_mater_class - Character (6)
8
- '-'
[9] insulation_purpose - Character (3)
**************** Label Type = 317 ****************
Label Name = Dgn review segment
Line no: [2]
Construction status: [4]
Nor oper press: [6][7]
Nor oper temp: [9][10]
Steam out temp: [12][13]
Heat tracing: [15]

356

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


Insulation: [17]
Cleaning: [19]
Piping Segment Data
1
- 'Line no: '
[2]
line_number_label - Character (30)
3
- 'Construction status: '
[4]
construction_stat - Character (15)
5
- 'Nor oper press: '
[6]
nor_oper_pres
- Real (8.2)
[7]
nor_op_pres_units - Character (10)
8
- 'Nor oper temp: '
[9]
nor_oper_temp
- Real (5.0)
[10] nor_op_temp_units - Character (5)
11
- 'Steam out temp: '
[12] steam_outlet_temp - Real (5.0)
[13] nor_op_temp_units - Character (5)
14
- 'Heat tracing: '
[15] heat_tracing_media - Character (5)
16
- 'Insulation: '
[17] insulation_thick
- Real (5.2) with sub units (ex. ",IN,MM,etc.)
18
- 'Cleaning: '
[19] cleaning_reqmts
- Character (10)

Plant Design System (PDS) Reference Data Manager (PD_Data)

357

Label Description Library

Mass Annotation Options


Selecting the Mass Annotation Options command activates the Mass Annotation Options
form.

This form allows you to specify the following options for use with the Mass Annotation command in
PD_Draw:
Are Previously Labeled Objects to be Labeled?
Are Objects Clipped by Drawing View Bounds to be Labeled?
Are Objects Hidden by Other Objects to be Labeled?

Operating Sequence
1. Place a data point on the desired selection under each question.
2. Accept the selections and return to the Create Label Graphic Data form.

Revise Label Data


This option enables you to revise the graphic data or attribute data for an existing label
description.

Operating Sequence
1. Select Revise from the Data Management form.

The system activates the following form which enables you to select the type of label to be

358

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


modified.

2. Select Option
Select the type of label to be revised. See Label Types (on page 343) for a description of all
the label types and subtypes.

The system displays the existing label for the selected label type.
3. Select Label Type
Select the specific label description to be revised.

Depending on the label type selected, the system displays the graphic data form or the
attribute data form.
For example, if you select label type 011, the system displays the following form.

Plant Design System (PDS) Reference Data Manager (PD_Data)

359

Label Description Library

4. Select the parameter to be modified and key in the new value for that parameter.
5. You can select Attribute Label Data to activate the attribute data form.

6. Set the option to Insert Data, Delete Data, or Edit Data. The default is Edit Data. Refer to
Create Label Attribute Data (on page 353) for information on these options.
7. When finished, select Accept to save the changes and return to the Revise Label Description
form.
OR

360

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


Select Cancel to exit without saving the changes.

Delete Label Data


This option enables you to delete an existing label description.

Operating Sequence
1. Select Delete Label Data from the Data Management form.

The system activates the following form which enables you to select the type of label to be
deleted.

2. Select Option
Select the type of label to be deleted. See Label Types (on page 343) for a description of all
the label types and subtypes.

The system displays the existing labels for the selected label type.
3. Select Label Type
Select the specific label description to be deleted.
4. Accept to Delete Label Type xxx
Select Accept to delete the selected label type.

The system deletes the description and refreshes the selection screen to enable you to delete
another label type.
5. Select Cancel to return to the Data Management form.

Report Label Data


This option creates a listing of the label types defined in the Label Description Library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

361

Label Description Library


Operating Sequence
1. Select Report Label Data from the Data Management menu.

2. Set the toggle to Unapproved or Approved to define the source of information to be reported.
This toggle is only displayed when both the approved and the unapproved library are being
used.
3. Select the reporting option.
Print/Delete submits the generated report output file to the specified print queue and
deletes the output file.
Print/Save submits the generated report output file to the specified print queue and
saves the output file.
Save saves the output file without printing.
For either of the Print options, the system displays a list of queues based on information in the
Project Queue Description Library.
4. Select Accept to submit the report for processing.
Report Completed
For either of the Save options, the system creates a file named LABEL.RPT in the default
directory. Portions of the listing for the delivered labels are provided below.
A RIS error may be displayed if an Electrical Raceway Database has not been created
as part of the PDS database. The error will only be reported the first time the report is run
each PDS session.
**************** Label Type = 1 ****************

362

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


Label Name = Line Number Label
Graphics Color = 4
Graphics Weight = 1
Graphics Style = 0
Text Color = 4
Text Weight = 1
Label Category = 0
Char Size = 0
Max Length = 40
Text Space = 0.400000
Number Line = 1
Text Font = 0
Enclosure Option = 9
Cell Enclosure Name =
Leader Line = 1
Line Terminator Char = >
Text Font = 125
Under Line = 0.000000
[1]
Piping Segment Data
[1] line_number_label - Character (40)
***************************************
**************** Label Type = 2 ****************
Label Name = Piping Component No
Graphics Color = 4
Graphics Weight = 1
Graphics Style = 0
Text Color = 4
Text Weight = 1
Label Category = 0
Char Size = 0
Max Length = 20
Text Space = 0.300000
Number Line = 1
Text Font = 0
Enclosure Option = 9
Cell Enclosure Name =
Leader Line = 1
Line Terminator Char = >
Text Font = 125
Under Line = 0.000000
[1]
Piping Component Data
[1] piping_comp_no
- Character (20)
***************************************
**************** Label Type = 200 ****************

Plant Design System (PDS) Reference Data Manager (PD_Data)

363

Label Description Library


Label Name = No Label Enclosure
Text Color = 4
Text Weight = 1
Label Category = 0
Char Size = 0
Max Length = 10
Text Space = 0.250000
Number Line = 2
Text Font = 0
Under Line = 0.000000
**************** Label Type = 201 ****************
Label Name = Rectangle Enclosure
Text Color = 4
Text Weight = 1
Label Category = 0
Char Size = 0
Max Length = 10
Text Space = 0.250000
Number Line = 2
Text Font = 0
Under Line = 0.000000
Attribute Data
***************************************
**************** Label Type = 300 ****************
Label Name = Piping Component ID
[1] / [3]
Connect Point
Piping Component Data
[1] commodity_name
- Character (6)
2
- ' / '
[3] model_code
- Character (6)
4
- 5 space(s)
5
- 'Connect Point '
***************************************
**************** Label Type = 301 ****************
Label Name = Piping Comp Center
[1] / [3]
Component Center
Piping Component Data
[1] commodity_name
- Character (6)
2
- ' / '
[3] model_code
- Character (6)
4
- 5 space(s)
5
- 'Component Center'
***************************************
**************** Label Type = 353 ****************
Label Name = Dgn Rvw Weld Label
Weld Number: [2] - [4]
Weld Type: [6]
Piping NPD/OD: [8] - [10]
PMC: [12]
Weld Attributes

364

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


1
- 'Weld Number: '
[2] weld_id - Character (16)
3
- ' - '
[4] weld_no_A - Character (8)
5
- 'Weld Type: '
[6] weld_type_A - Character (20)
7
- 'Piping NPD/OD: '
[8] nom_pipe_diam_A - Character (20)
9
- ' - '
[10] outside_diam_A - Real (15.4)
11
- 'PMC: '
[12] piping_mater_class - Character (16)
***************************************
**************** Label Type = 400 ****************
Label Name = Comp cmdty code
[1]
Piping Component Data
[1] commodity_code
- Character (16)
***************************************
**************** Label Type = 401 ****************
Label Name = Pipe sch/thk 1
[1]
Piping/Tubing Data
[1] schedule_thickness - Character (8)
***************************************
**************** Label Type = 404 ****************
Label Name = 1/2CP COMP GCP
[1]
Piping Component Data
[1] CP_1_NOM_PIPE_DIAM
***************************************
**************** Label Type = 405 ****************
Label Name = 2CP RED COMP GCP X RCP
[1] X [3]
Piping Component Data
[1] CP_1_NOM_PIPE_DIAM
2 'X'
[3] CP_2_NOM_PIPE_DIAM
***************************************
**************** Label Type = 408 ****************
Label Name = 3CP RED COMP GCP x RCP
[1] CP_1_NOM_PIPE_DIAM
2 'X'
[3] CP_3_NOM_PIPE_DIAM
***************************************
**************** Label Type = 410 ****************
Label Name = 3CP COMP RCP
[1] CP_3_NOM_PIPE_DIAM
***************************************
**************** Label Type = 950 ****************
Label Name = MAL nozzle descr
[1] [3]
Nozzle Data

Plant Design System (PDS) Reference Data Manager (PD_Data)

365

Label Description Library


[1] nominal_piping_dia - Character (9)
2
- 1 space(s)
[3] preparation - Character (8)
***************************************
**************** Label Type = 951 ****************
Label Name = Iso continuation
[1][2]-[4][5]
Piping Segment Data
[1] unit_code
- Character (3)
[2] line_sequence_no
- Character (16)
3
- '-'
[4] fluid_code
- Character (5)
[5] design_area_number - Character (12)
***************************************
**************** Label Type = 1150 ****************
Label Name = Line ID
[1][2]-[4]
Piping Segment Data
[1] unit_code
- Character (3)
[2] line_sequence_no
- Character (16)
3
- '-'
[4] fluid_code
- Character (5)
***************************************
**************** Label Type = 1151 ****************
Label Name = Iso no
[1][2]-[4][5]
Piping Segment Data
[1] unit_code
- Character (3)
[2] line_sequence_no
- Character (16)
3
- '-'
[4] fluid_code
- Character (5)
[5] design_area_number - Character (12)
***************************************
**************** Label Type = 2200 ****************
Label Name = Specialty 2cp (1st)
[1]
Piping Component Data
[1] piping_comp_no
- Character (20)
***************************************
**************** Label Type = 2201 ****************
Label Name = Specialty 3cp (1st)
[1]
Piping Component Data
[1] piping_comp_no
- Character (20)
***************************************

Label Library Merger


The Label Library Merger utility allows PDS users to copy labels from one or two label
description libraries into another library and to modify the destination library as necessary. You
can only add and remove labels with this command. To edit an existing label or create a new label
definition, use the Label Description Library Manager command.

366

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


Features

Copy labels from one library to another.


Delete an existing label from the destination library.
Rename an existing label in the destination library.
Compress the destination library.
Validate the destination library.

Label Library Merger Interface


This section contains descriptions of the Label Library Merger interface, including information on
all dialog boxes and commands. The Label Library Merger commands are available from the
toolbar and from menus.

The Label Library Merger dialog box contains three label description library views. The two
views on the left display the contents of the source libraries, and the view on the right displays the
contents of the destination library. Each library view is divided into two columns, Number and
Description, which display the appropriate data for each label. You can click a heading in any
library view to sort the labels by that heading.
The bottom pane of the Label Library Merger dialog box is the message window, which displays
errors and other informational messages during the library merge workflow.

File Menu
The commands on the File menu allow you to open libraries, display information in the Message
Window, and exit the Label Library Merger.

Plant Design System (PDS) Reference Data Manager (PD_Data)

367

Label Description Library


Open Source Label Library 1
This command opens a label description library from which to copy labels. You can key in or
browse to the location of a source library. The system displays the label number and description
in the Library 1 View.

Open Source Label Library 2


This command opens a second label description library from which to copy labels. Using a
second source library is optional, and not required for the use of this command. The system
displays the label number and description in the Library 2 View.

Open Destination Library


This command opens a new or existing destination library, where labels from the source libraries
are copied. The system displays the copied label numbers and descriptions in the Destination
Library View.
To create a new destination library, browse to the appropriate folder in the Open Destination
Library dialog box, type a new library name in the File name text box, and click Open. The
system will then create the new label description library in the specified location.

Information
This command displays information in the Message Window regarding the source and
destination libraries.

Example
MESSAGE: D:\WIN32APP\INGR\PDSHELL\lib\labels.l Opened as Source Label
Library 1
MESSAGE: D:\WIN32APP\INGR\PDSHELL\lib\company_labels.l Opened as Source
Label Library 2
MESSAGE: D:\WIN32APP\INGR\PDSHELL\lib\all_labels.l Opened as Destination
Label Library

Exit
This command closes the Label Library Merger utility.

Edit Menu
The commands on the Edit menu allow you to modify your selections in the various views on the
Label Library Merger dialog box, modify and delete the label information in the destination
library, and check the destination library for errors.

Select All
This command selects all the labels in the active view.

368

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library


Unselect All
This command resets selections so that no labels in the active view are selected.

Invert Selection
This command switches the selection status of the labels in the active view, so that labels that are
currently selected become unselected, and labels that are currently not selected become
selected.

Edit Label Number


This command allows users to modify the label number of the selected label in the Destination
Library View.

Edit Label Description


This command allows users to modify the label description of the selected label in the Destination
Library View.

Delete
This command removes the selected labels from the destination library.

Validate
This command checks the labels in the destination library for valid label numbers, and reports any
invalid label numbers in the Message Window.

Compress Destination Library


This command removes the deleted labels from the destination library.

Copy to Destination
This command copies the selected labels from the source libraries to the destination library. The
system uses the following criteria to determine label numbers:
If there is no label in the destination library with the same label number as the label being
copied, the label is copied with its original label number.
If there is a label in the destination library with the same label number as the label being
copied, the label is copied with a new label number, which is assigned using the following
criteria:
If there is an unassigned label number in the copied label's category in the destination
library, the system assigns the next available label number in that category.
If there is no unassigned label number in the copied label's category in the destination
library, the system adds 5000 to the label number and copies the label. For example,
label number 23 in the source library is copied to label 5023 in the destination library.
Label numbers above 5000 generate errors in PDS. The Validate command
reports any such label numbers in the Message Window.
Refer to Label Description Library (on page 343) for more information on label categories.

Plant Design System (PDS) Reference Data Manager (PD_Data)

369

Label Description Library


Clear Error Messages
This command refreshes the Message Window.

Help Menu
The commands on the Help menu display online Help and other information about the Label
Library Merger utility.

Contents
This command displays the Label Library Merger online Help file.

About Library Merger


This command displays the About dialog box with information about the Label Library Merger
utility, including the version number and copyright date.

Label Library Merge Workflow


This section describes the general workflow for the Label Library Merger utility.
1. Click Start > Programs > PD_Shell > PDS Label Library Merger to start the Label Library
Merger utility.

The Label Library Merger interface displays.

370

Plant Design System (PDS) Reference Data Manager (PD_Data)

Label Description Library

2. Click File > Open Source Label Library 1.


3. Browse to the location of the first label description library, select the library, and click Open.

The system displays the contents of the library in the Library 1 View.
4. Repeat the previous two steps for the second label description library.

The system displays the contents of the library in the Library 2 View.
5. Click File > Open Destination Library. You can either open an existing library for update or
create a new library.

The system displays the contents of the destination library in the Destination Library View.
6. Select labels in the existing label description libraries to copy to the destination library. Use
CTRL+click to select multiple labels, or SHIFT+click to select a range of labels. Use the
selection commands on the Edit menu to select all labels, unselect all labels, or invert your
selections.
7. Click Edit > Copy to Destination to copy the selected labels to the destination library.

The system displays the copied labels in the Destination Library View.
8. Click Edit > Edit Label Number or Edit > Edit Label Description to modify labels in the
destination library as necessary.
9. Click Edit > Validate to check the destination library for errors.

The system displays any warnings in the Message View.


10. Click Edit > Compress Destination Library to compress the destination library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

371

Label Description Library


The system displays any warnings in the Message View.

11. When you are finished modifying the destination library, click File > Exit to exit the Label
Library Merger utility.

372

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 15

Piping Assembly Library


The Piping Assembly Language (PAL) enables you to define the parameters necessary to place a
piping assembly (group of components) automatically in the model. This function is most useful
for a commonly placed group of components.
The PAL definition is compiled and stored in Piping Assembly Language object library and its text
stored in the text library.
A Piping Assembly Library which contain the definitions for basic assemblies (macros) is included
in the product delivery.
\win32app\ingr\pdshell\lib\assembly.l
The PAL definition must be processed and stored in the Piping Assembly Library.

See Also
Piping Assembly Language (on page 373)
Piping Assembly Library Manager (on page 386)

Piping Assembly Language


The Piping Assembly Language provides a set of functions to define the placement operation.
You can create a PAL definition outside the PDS environment using a text editor.

PAL Keywords
The following list outlines all the keywords that can be used to create a PAL definition. Keywords
followed by a number in (parentheses) such as
NPD_A (3221), NPD_B (3222), NPD_C (3223)
are used to create form gadgets for defining and placing piping assemblies. The number
represents the application command number for the keyword. The key entry field number is this
number minus 3000. (Therefore, the key entry field number for NPD_A is 221.)

Formbuilder Guidelines
You can customize forms for the purpose of inputting data in the creation of a piping assembly,
such as a control station. You can use the gadget numbers for the corresponding input fields.
You must adhere to the following conventions when customizing form input fields for the
applicable piping assembly. If not documented, any other gadgets on the form should remain
consistent with those delivered by Intergraph.

Plant Design System (PDS) Reference Data Manager (PD_Data)

373

Piping Assembly Library


All input fields should be sequenced and must have the following characteristics. The Edit Field
Options setting in the Form Builder should be Change Mode.

The characteristics form in the Form Builder should have the following settings.
Notify Upon Completion - off (NOT the default)
Notify at Initial Selection - off
The forms delivered by Intergraph can be used as examples for customization. The following list
the form builder data for the standard form gadgets.
Help

key:

456

gadget number:

995

button:

automatic

Form Size
key:

403

gadget number:

997

button:

automatic

Exit

374

key:

4001

gadget number:

998

button:

manual

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


Accept

key:

4002

gadget number:

999

button:

manual

Message Area A - for


messages
gadget number:

251

characters:

40

lines deep:

edit mode:

review only

font size:

12

Message Area B - for active segment data


display
gadget number:

254

characters:

40

lines deep:

edit mode:

review only

font size:

12

Material description
display
gadget number:

150

characters:

80

lines deep:

edit mode:

review only

font size:

12

Description
#
This keyword is used to specify a description for the piping assembly from within the assembly
language file. Place a # in the first column of any line followed by a description of as many as 100
characters.
Examples:
# Control Station

Plant Design System (PDS) Reference Data Manager (PD_Data)

375

Piping Assembly Library


Commands
COMMAND
This keyword is used with other keywords to initiate a defined action.
Examples:
COMMAND = GET_TUTORIAL_DATA
COMMAND = UPDATE_APP
COMMAND = POINT_IN_SPACE
CONNECT
This keyword defines the active point for the next component placed in the PAL definition. The
specified reference point must be defined before using this option.
Example: CONNECT TO REF_PNT_A
PLACE
This keyword defines the type of item to be placed. Refer to the PLACE Command Component
keywords for a list of component/instrument types.
Example: PLACE FITTING , 6Q2C01 ,
BY
This keyword is used with the PLACE keyword to set the placement mode to be used in placing
the specified component. Refer to the Connect Point keywords for a list of viable placement
modes.
Example: PLACE FITTING , 6Q2C01 , BY CP1
STEM
This keyword is used with an orientation keyword to define the direction of the secondary axis. It
can be used at the end of a PLACE statement.
Example: PLACE FITTING , 6Q2C01 , BY CP1 , STEM = UP

PLACE Command Components


FITTING, VALVE, FLANGE, BRANCH, PIPE, SPECIALTY, INSTRUMENT, OPTIONAL, TAP
These keywords are used with the PLACE keyword to define the type of item to be placed.
Example:
PLACE FITTING , 6Q2C01 , BY CP1
PLACE BRANCH , 90_DEG , BY CP1
PLACE PIPE TO REF_PNT_A
PLACE OPTIONAL , 6Q2C01, BY CP2
RDB_INSTRUMENT, RDB_SPECIALTY
These keywords are used to place instruments and specialty items that have been defined in the
PJS using the tag number.
Example: PLACE RDB_INSTRUMENT, INSVLV1, BY CP1

Connect Point
CENTER, CP1, CP2, CP3, CP4, CP5
ACTIVE_PP
FACE_OF_FLANGE_CP1, FACE_OF_FLANGE_CP2,
FACE_OF_FLANGE_CP3
These keywords identify the connect point for an operation. They can be used with the BY
keyword to indicate the means of placement.
Example: PLACE VALVE, 6Q1C38, BY CP1

376

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


INLET_ELEVATION
This keyword sets the starting elevation or point of connection.
Example:
REF_PNT_A = ACTIVE_PP
COORDINATE_1 = INLET_ELEVATION

Orientation
ACTIVE
EAST, NORTH, UP
WEST, SOUTH, DOWN
These keywords identify the orientation direction.
Example: PLACE FITTING, 6Q2C01, BY CP1, STEM = UP

No Material TakeOff
NO_MTO=1
This keyword can be used immediately before a PLACE statement to specify that the component
is not reportable. The system automatically resets MTO processing after placement.

Assembly End Keywords


ASSEMBLY_END_A, ASSEMBLY_END_B
These keywords define an assembly end point as a specified coordinate value. An assembly end
definition is used to define the endpoints of an assembly. This is required when the assembly is
being placed into a pipe so that the pipe is broken properly and the assembly inserted (as in the
case of a valve assembly: flange - valve - flange).
Example: ASSEMBLY_END_A = CP2

Reference Point Keywords


REF_PNT_A, REF_PNT_B, ... REF_PNT_T
ACTIVE_PP, NOZZLE
These keywords set reference points at specified coordinate values. You can define up to 20
points on the assembly for future reference in the PAL definition.
Example: REF_PNT_A = CP_1
Once a reference point is defined, it can be used by a following statement in the PAL definition to
indicate a coordinate location (for example, CONNECT TO REF_PNT_A).

Generic End Types


NULL_GEN_TYPE, BOLTED, FEMALE, MALE
These keywords specify the generic termination type for use in conditional testing.

Number of Connect Points


NUMBER_CPS
This keyword contains the number of connect points of the component just placed. It can be
used in branch placement to determine whether to use CP2 or CP3 as a reference point.
Example:
IF (NUMBER_CPS .EQ. 2.0) THEN
REF_PNT_A = CP2

Plant Design System (PDS) Reference Data Manager (PD_Data)

377

Piping Assembly Library


ELSE
REF_PNT_A = CP3
ENDIF

Commodity Item Name


ITEM_NAME
This keyword defines an item name to be used for placement.
Example: ITEM_NAME = xxxxxxx
COMPONENT_TAG (3246)
This keyword defines the tag for the component to be placed. You can prompt for the tag or use
the tutorial interface using the designated field and command numbers.
Example:
COMPONENT_TAG = USER_INPUT

UORs per Model Subunit


UORS_PER_SUBUNIT
This keyword defines the number of UORs per Subunit defined in the model. It can be used to
calculate tap location.

Local Coordinates and Orientation


APP_X, APP_Y, APP_Z
These keywords define the active placement point which can be used in the connect to segment
and point in space routines. These keywords are initially set to the active placement point of the
assembly at the start of the assembly placement.
COORDINATE_1 (3191) ... COORDINATE_12 (3203)
DIMENSION_1 - DIMENSION_20
These keywords are used to receive user input from the tutorial to define the active placement
point. The Coordinate keywords identify actual points and the Dimension keywords identify
distances and offsets. The Coordinate keywords are only used for elevation values, not Easting
or Northing values.
Example: APP_Z = COORDINATE_1
COORDINATE_2 = INLET_ELEVATION
LOCAL_X, LOCAL_Y, LOCAL_Z
These keywords are defined as the active primary, secondary, and normal axis at the time the
assembly is placed. They are automatically set internally at the start of placement and cannot be
modified.

Dimension Definition
DIMENSION_1 (3141), DIMENSION_2 (3142), ... DIMENSION_20 (3160)
The Dimension keywords identify distances and offsets.

Move Specified Distance


MOVE_DISTANCE
This keyword moves a specified distance in the direction of the active primary. It is useful in
placing a variable length pipe by moving out a specified distanced and calling place pipe.
Example: MOVE_DISTANCE = DIMENSION_1
PLACE PIPE TO REF_PNT_A

378

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


Load Spec Data
LOAD_SPEC_DATA
This keyword reads the spec record for the commodity item and assigns values for the following
keywords:
TERM_TYPE_1, TERM_TYPE_2, ... TERM_TYPE_5
PR_RATING_1, PR_RATING_2, ... PR_RATING_5
GEN_TYPE_1, GEN_TYPE_2, ... GEN_TYPE_5
Example:
LOAD_SPEC_DATA = '6Q1C80'
IF ( GEN_TYPE_1 .EQ. BOLTED ) THEN
OPTION_RATING = PR_RATING_1
OPTION_END_PREP = TERM_TYPE_1
PLACE OPTIONAL , 6Q2C01 , BY CP2
ENDIF

Setting First and Second Size


FIRST_SIZE, SECOND_SIZE, NPD_STEP_UP, NPD_STEP_DOWN
These keywords set the active first size or second size placement parameter a step down/up in
the NPD piping material class table. (The system uses the next entry in the NPD table from the
active size as the first/second size for a step up or next higher size and uses the previous entry in
the NPD table from the active size as the first/second size for a step down or lower size). This
particular statement in PAL is used as the active size (first or second) in the placement of all the
following components, until the active size is redefined. If you do not include a line size in the
PAL definition, the active size at the time of placement of the piping assembly will be used.
Example: FIRST_SIZE = NPD_STEP_DOWN

Coordinates of Component Just Placed


COMPONENT_CENTER, CP_1_LOCATION, CP_2_LOCATION
COMPONENT_CENTER_X, _Y, _Z
CP_1_LOCATION_X, _Y, _Z
CP_2_LOCATION_X, _Y, _Z
These keywords define coordinate values for the component just placed.
Example: TAP_LOCATION_Y = COMPONENT_CENTER_Y + DELTA_DISTANCE *
UORS_PER_SUBUNIT

Outside Diameter
PIPE_OD_CP1, PIPE_OD_CP2
These keywords contain the pipe outside diameter at each connect point for the component just
placed. These values can be used to calculate a tap location.
Example: DELTA_DISTANCE = ( PIPE_OD_CP1 - PIPE_OD_CP2 ) / 4.0
FLANGE_OD_CP1, FLANGE_OD_CP2
These keywords contain the flange outside diameter at each connect point for the component just
placed. These values can be used to calculate a tap location.

Tutorial Display and Acquisition


DISPLAY_TUTORIAL, DISPLAY, DISPLAY_NUMERIC
DISPLAY_TUTORIAL = 'PALCST'

Plant Design System (PDS) Reference Data Manager (PD_Data)

379

Piping Assembly Library


PROMPT_MESSAGE = 'Keyin coordinates and valve data'
DISPLAY = prompt_message
used to display any ascii keyword.
DISPLAY_NUMERIC = npd_a
used to display any numeric keyword.
COMMAND = GET_TUTORIAL_DATA
used to get data from the user at placement via a tutorial.
GET_ASCII, GET_DECIMAL, GET_INTEGER
These keywords get data of a specified type from a user keyin.

Prompt for ASCII Input


USER_INPUT

Updating Active Place Point


Example:

COMMAND = UPDATE_APP

The variables APP_X, APP_Y, and APP_Z are assigned the X, Y, and Z values of the current active
placement point. This command is useful for variable distance changes in assemblies, and you
need to know the new coordinates.

Point in Space
Example:

COMMAND = POINT_IN_SPACE

The values of the keywords APP_X, APP_Y, and APP_Z are used to define the active placement
point that is not connected to piping or a piping segment. These keywords need to be set before
POINT_IN_SPACE is called.

Connect to Piping Segment


Example:

CONNECT TO APP

The command syntax is the same as for connecting to a reference point except that the keywords
APP_X, APP_Y, and APP_Z are used as the coordinates. These points are assumed to lie on a
piping segment whereas a reference point identifies a connect point. The keywords should be
set before this command is called.

Orientation of Primary and Secondary


ORIENTATION, PROMPT, ORIENT_SECONDARY, ORIENT_PRIMARY, INVERT
ORIENT_PRIMARY = LOCAL_X
This statement orients the primary axis to be the same as the primary at the beginning of the
assembly placement.
ORIENT_SECONDARY = LOCAL_Y
This statement orients the secondary to be the same as the secondary at placement.
ORIENT_SECONDARY = INVERT
This statement allows the secondary to be inverted from its current position. You can also use
INVERT for the primary axis.

Placement of BRANCH using Table Lookup


90_DEG, 45_DEG, VARIABLE
Example:

380

PLACE BRANCH, 90_DEG , BY CENTER

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


This statement performs a table lookup on the 90 degree branch table to determine the branch
component type given the current first and second size. If the branch is on a piping segment or in
free space, then Placement BY CENTER should be used. If you are placing fitting to fitting, you
should specify connect point placement (BY CP1).

Placement of OPTION flange


OPTION_RATING, OPTION_END_PREP
Example:
IF ( END_PREP_A .GE. 2.0 .and. END_PREP_A .LE. 199) THEN
OPTION_RATING = RATING_A
OPTION_END_PREP = END_PREP_A
PLACE OPTIONAL, 6Q2C01 , BY CP2
ENDIF
The keywords OPTION_RATING and OPTION_END_PREP values are used to determine which
option to use for the specified flange.
OPTION_TBL_SUFFIX
TBL_SUFFIX_GREEN, TBL_SUFFIX_RED
END_PREP_1, END_PREP_2, ... END_PREP_5
TBL_SUFFIX_A (301), TBL_SUFFIX_B (302), ... TBL_SUFFIX_E (305)
These keywords provide the ability to select the correct optional flange, when the flange is being
placed by its welded end.

Placement of Optional Components


OPTION_CODE
Examples:
OPTION_CODE = PROMPT
OPTION_CODE = 790
This keyword sets the option code for the next component placed. If the PROMPT keyword is
used, the system activates the Option Code Selection tutorial at placement to enable the user to
select the option code. Otherwise, the option code is hard-coded.

Placement of Variable Length Pipe


Example:

PLACE PIPE TO REF_PNT_E

Logical Marks
CHECK_MARK
CHECK_MARK_1 (3161), CHECK_MARK_2 (3163), ... CHECK_MARK_20 (3180)
The check marks are logical keywords that can be accessed through the tutorial. They can be
used for testing for placement of components, etc. Initially, they are all set to true.

Changing Piping Materials Class within an Assembly


ACTIVE_MATERIALS_CLASS (3205)
MATERIALS_CLASS_A (3206), MATERIALS_CLASS_B (3207), MATERIALS_CLASS_C
(3208)
MATERIALS_CLASS_D (3264), MATERIALS_CLASS_E (3265), ... MATERIALS_CLASS_J
(3270)
Example:

Plant Design System (PDS) Reference Data Manager (PD_Data)

381

Piping Assembly Library


MATERIALS_CLASS_B = USER_INPUT
ACTIVE_MATERIALS_CLASS = MATERIALS_CLASS_B
The values for materials class can be:
obtained from the tutorial using the predefined fields
defined by prompt (USER_INPUT)
hard-coded in the PAL definition.
The values for MATERIALS_CLASS_A through _J are stored locally until a statement with
ACTIVE_MATERIALS_CLASS is executed. At that time, the Materials Class in the active data is
updated to the assigned value. This enables you to obtain up to three different classes from the
tutorial at the start which can be used as needed in the definition.

Component Attributes
NPD_A (3221), NPD_B (3222), NPD_C (3223)
NPD_D (3284), NPD_E (3285), ... NPD_J (3290)
These keywords store nominal piping diameter values.
END_PREP_A (3231), END_PREP_B (3232)
These keywords store end preparation values.
RATING_A (3236), RATING_B (3237)
These keywords store pressure rating values.
SCHEDULE_A (3241), SCHEDULE_B (3242)
These keywords store schedule/thickness values.

Setting Bend Angle


ACTIVE_BEND_ANGLE (3211)
BEND_ANGLE_A (3212), BEND_ANGLE_B (3213), ... BEND_ANGLE_E (3216)
Example:
BEND_ANGLE_A = PROMPT
ACTIVE_BEND_ANGLE = BEND_ANGLE_B
The values for bend angle can be:
obtained from the tutorial using the predefined fields
defined by prompt
hard-coded in the PAL definition
The active bend angle in the model is not set until a statement with ACTIVE_BEND_ANGLE is
executed. At that time, the active bend angle is assigned the appropriate value and the next
component placed uses that value. The active bend angle is set to 0 after placement.

Component Group
COMPONENT_GROUP, ON, OFF
Example:

COMPONENT_GROUP = ON

This statement causes the system to search for the next available component group number.
This number is assigned to the component group number attribute of each subsequent
component placed until the statement COMPONENT_GROUP = OFF is executed or the assembly is
completed.

382

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


Local Variables
You can use local variables to store values for use in defining a piping assembly. You can use
any alphanumeric string as long as it is not reserved as a keyword.

Test Attribute Values


T12C# - Piping Segment Data
T34C# - Piping Component Data
T50C# - Pipe Data
T67C# - Instrument Component Data
You can use these keywords to test specific values of the active segment data or active
component data, where # refers to the column (attribute) number for the applicable database
table. The active component data is represented by the last component placed or the component
to which the user is connected.

Pre-Define Attribute Values


T34C# - Piping Component Data
T50C# - Pipe Data
T67C# - Instrument Component Data
You can use these keywords to pre-define specific values for the component to be placed, where
# refers to the column (attribute) number for the applicable database table. This functionality is
similar to the Pre-Define Component Data option of the Place Component command.
If you pre-define a value for fabrication category, the component will be designated as
having the fabrication category defined by user versus by system such that reconstructing the
component will not override the user value with the value in the Reference Database.
Having the ability to pre-define the fabrication category within a control station piping assembly will
enable you to automatically override the RDB specification of the fabrication category of a single
field component, such as a small diameter control valve, in what would otherwise be a shop spool.
See Placing Taps in Assemblies (on page 383) for additional information on PAL keywords.

Placing Taps in Assemblies


The syntax for placing taps in assemblies is outlined below:
PLACE TAP , 2.0 , 1
where 2.0 is the tap NPD and 1 is the option code.
PLACE TAP BY CPn
CPn designates the connect point from which to obtain the tap data.
The following PAL definitions should be used to specify the tap location before making the PLACE
TAP request.
TAP_LOCATION = COMPONENT_CENTER
CP_1_LOCATION
CP_2_LOCATION
COMPUTE_FOR_ELBOLET_USING_CP1
COMPUTE_FOR_ELBOLET_USING_CP2
OR
TAP_LOCATION_X = COMPONENT_CENTER_X +- delta_distance
CP_1_LOCATION_X +- delta_distance
CP_2_LOCATION_X +- delta_distance
TAP_LOCATION_Y = COMPONENT_CENTER_Y +- delta_distance
CP_1_LOCATION_Y +- delta_distance

Plant Design System (PDS) Reference Data Manager (PD_Data)

383

Piping Assembly Library


CP_2_LOCATION_Y +TAP_LOCATION_Z = COMPONENT_CENTER_Z
CP_1_LOCATION_Z +CP_2_LOCATION_Z +-

delta_distance
+- delta_distance
delta_distance
delta_distance

The keywords PIPE_OD_CP1, PIPE_OD_CP2, FLANGE_OD_CP1, and FLANGE_OD_CP2 can be


used to calculate the delta distance. These values are based on the component just placed in the
assembly.
For TAP_LOCATION_X, _Y, _Z, the X, Y, and Z represent a local coordinate system that
is analogous to the orientation at Connect point 1 of the component flipped to point towards the
inside of the component.
The tap orientation should also be set before making the PLACE TAP request using the PAL
orientation commands. The active orientation at time of placement (tap) is used.

Sample Piping Assembly Files


This section presents sample PAL files from the delivered Piping Assembly Library. It lists the
files and shows the resulting graphics created by the file. Refer to the Piping Design Graphics
Reference Guide for more information on placing piping assemblies with the Place Component
command.

DRAIN
# Drain assembly
PAL 'DRAIN'
!
! This assembly will place a drain. The user needs to place a 1"
! sockolet at the point the drain is desired.
!
PLACE FITTING, 6Q3C88 , BY CP1
!
! The data from the component spec is read into the keywords.
! TERM_TYPE_1 TO 5 gets the numeric value for end preparation (eg. 21)
! PR_RATING_1 TO 5 gets the pressure rating
! GEN_TYPE_1 TO 5 gets the textual value for end preparation (eg. MALE)
!
LOAD_SPEC_DATA = '6Q1C76'
!
! This 'IF' statement determines if an optional flange is needed before
! the gate valve is placed.
!
IF ( GEN_TYPE_1 .EQ. BOLTED ) THEN
OPTION_RATING = PR_RATING_1
OPTION_END_PREP = TERM_TYPE_1
PLACE OPTIONAL , 6Q2C01 , BY CP2
ENDIF
!
! Places a gate valve. Notice in the spec that this type of gate valve
! is different than a 6Q2C01.
!
PLACE VALVE, 6Q1C76 , BY CP1
IF ( GEN_TYPE_2 .EQ. BOLTED ) THEN
OPTION_RATING = PR_RATING_2

384

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


OPTION_END_PREP = TERM_TYPE_2
PLACE OPTIONAL , 6Q2C01 , BY CP1
ENDIF
!
! This command allows the user to pick which component to place. If the
! option command is not used the s/w will choose option 1. In this instance,
! without the OPTION_CODE command will cause an error because there are no
! option 1 attributes available for 6Q2C16. Another possiblilty would be
to
! use OPTION_CODE = PROMPT. The user will be prompted for which component
is
! desired.
!
OPTION_CODE = 163
PLACE FITTING, 6Q2C16 , BY CP1
END

Graphics Placed by Drain Assembly

Pump Discharge Assembly


# Pump Discharge
PAL
'PDISC1'
!
!
Pump Discharge
!
!
DISPLAY_TUTORIAL = 'PAS010'
NPD_A = FIRST_SIZE
DISPLAY_NUMERIC = NPD_A
NPD_B = SECOND_SIZE
DISPLAY_NUMERIC = NPD_B
PROMPT_MESSAGE = 'Enter Reducer First Size
'
DISPLAY = PROMPT_MESSAGE
COMMAND = GET_TUTORIAL_DATA
PLACE FLANGE , 6Q2C01 , BY CP1
FIRST_SIZE = NPD_A
DELTA_DISTANCE = ( PIPE_OD_CP1 * 0.5 - PIPE_OD_CP2 * 0.5) / 2.0
PLACE FITTING , 6Q2C23 , BY CP2

Plant Design System (PDS) Reference Data Manager (PD_Data)

385

Piping Assembly Library


TAP_LOCATION_Y = COMPONENT_CENTER_Y - DELTA_DISTANCE *
UORS_PER_SUBUNIT
ORIENT_PRIMARY = LOCAL_Y
ORIENT_SECONDARY = LOCAL_X
PLACE TAP BY CP1
REF_PNT_A = CP1
REF_PNT_B = CP3
CONNECT TO REF_PNT_B
NPD_C = SECOND_SIZE
DISPLAY_NUMERIC = NPD_C
PROMPT_MESSAGE = 'Enter Branch Size
DISPLAY = PROMPT_MESSAGE
COMMAND = GET_TUTORIAL_DATA
SECOND_SIZE = NPD_C
PLACE BRANCH , 90_DEG , BY CP1
OPTION_CODE = PROMPT
PLACE FITTING , 6Q3C88 , BY CP1
ORIENTATION = PROMPT
PLACE VALVE , 6Q1C80 , BY CP1
CONNECT TO REF_PNT_A
PLACE FLANGE , 6Q2C01 , BY CP2
PLACE VALVE , 6Q1C38 , BY CP1
ORIENTATION = PROMPT
PLACE VALVE , 6Q1C01 , BY CP1
PLACE FLANGE , 6Q2C01 , BY CP1
END

'

Graphics Placed by Pump Discharge Assembly

Piping Assembly Library Manager


The Piping Assembly Library Manager enables you to create a new (empty) piping assembly
library or create, revise, and delete piping assembly definitions in an existing library. The Piping
Assembly Language (PAL) enables you to define the parameters necessary to place a piping
assembly (group of components) automatically in the model. This function is most useful for a
commonly placed group of components.

386

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


Refer to Piping Assembly Library (on page 373) for more information on this library, and refer to
Piping Assembly Language (on page 373) for more information on the PAL files.

Before Using This Command

Define the location of the approved and unapproved (if applicable) Assembly Library files in
the Reference Database Management Data.
You must have write access to the specified file and directory path.

Options

Create Library (on page 388) used to create a new Piping Assembly Library.
Compress (on page 388) used to compress the Piping Assembly library.
Unapproved ==> Approved (on page 388) used to copy the unapproved Piping Assembly
library to the approved library.
Create/Interactive Data (see "Create/Interactive Piping Assembly Data" on page 388) used
to compile Piping Assembly Language source files and insert them in the Piping Assembly
Library.
Create/Batch Data (see "Create/Batch Assembly Data" on page 389) used to compile
Piping Assembly Language Source files via batch processing.
Revise Data (see "Revise Piping Assembly Data" on page 389) used to select an PAL
module from the library, edit the file, and put the revised file back into the library.
Delete Data (see "Delete Piping Assembly Data" on page 391) used to remove an PAL
module from the library.
Report Data (see "Report Assembly Data" on page 392) used to create a report of the
library contents.
List Data (see "List Assembly Data" on page 393) used to display the Eden modules in the
library.
Extract Data (see "Extract Assembly Data" on page 394) used to extract an Eden module
from the library for editing or printing.

Plant Design System (PDS) Reference Data Manager (PD_Data)

387

Piping Assembly Library

Full List / Sub-string You can set the toggle at the bottom of the form to determine the
assembly data tables to be listed.
Full List lists all the assembly definitions in the Assembly Library.
Sub-string limits the list to those files which contain a specified substring.

Create Library
This option is used to create a new Piping Assembly Library. It automatically creates the object
library (.l) and the text library (.l.t) for the library that is being created.
The system displays the approved and unapproved Piping Assembly Library names as defined in
the RDB Management Data.

Accept to Create or Exit to Avoid Creating New Library


Select Accept to create the specified library files. If you specify an existing library file, the
system displays an error indicating the library already exists.

Compress
This option is used to compress the Piping Assembly library. Any tables which have been
deleted from the library will be removed.

Unapproved ==> Approved


This option copies the unapproved Piping Assembly library to the approved library.

Accept to Copy or Exit to Avoid Copying


Select Accept to copy the unapproved library file to the approved library.

Create/Interactive Piping Assembly Data


This option enables you to compile PAL source code into object code and insert the specified files
into the Piping Assembly library. You can process a single file or specify a list of files to be
created. Refer to the description of the Piping Assembly Library (on page 373) for more
information on Piping Assembly Language modules.

Before Using This Command

To add more than one PAL file to the library, create a list file which identifies the names of the
source files to be added. The list file should contain one entry (source file name) per line.
Set Assembly Path and Assembly Node in the RDB Management Data to the location of the
assembly source files.

Operating Sequence
1. Select the Create/Interactive option.

2. Set the toggle to Single to process a single source file or to List to process a list file.

388

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


3. Specify Filename for Processing
Key in the name of the PAL file or list file to be compiled and added to the active library.

The system displays the default node name and path for the location of the PAL files at the
bottom of the form.
You can use the default options or override the values for this operation.
4. Accept or Select Other Option
Accept the file to begin processing.

Create/Batch Assembly Data


This option enables you to compile PAL source code into object code and insert the specified files
into the Piping Assembly library. The specified files are submitted to the batch queue
PDreference for processing.

Before Using This Command

To add more than one PAL file to the library, create a list file which identifies the names of the
source files to be added. The list file should contain one entry (source file name) per line.
Set Assembly Path and Assembly Node in the RDB Management Data to the location of the
assembly source files.

Operating Sequence
1. Select the Create/Batch option.

2. Set the toggle to Single to process a single source file or to List to process a list file.
3. Specify Filename for Processing
Key in the name of the PAL file or list file to be compiled and added to the active library and
select Accept.

The system displays the default node name and path for the location of the PAL files at the
bottom of the form.
You can use the default values or override the values for this operation.
4. Accept to Submit or Specify Submit Time
Set the toggle to Submit Immediately or Delayed Submit.
For Delayed Submit, set the time and day to process the files.
5. Accept the file to begin processing.

The system submits the request to the batch queue PDreference.

Revise Piping Assembly Data


This option enables you to select a PAL module from the library, edit the file, and then compile the
file and put it back in the library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

389

Piping Assembly Library


Before Using This Command
Set the toggle to Full List or Sub-string to determine the PAL files to be listed.

Operating Sequence
1. Select the Revise option.

The system displays the PAL modules in the Piping Assembly Library.

2. Select Assembly for Revision


Select the PAL modules to be revised and select Accept.

The system extracts the specified file from the library and activates the text editor (specified
for PD_EDITOR in the control.sh file) to enable you to modify the file.

390

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library

3. Make any changes to the displayed file.

When you exit the text editor, the system compiles the revised file and inserts it back into the
library. (If you quit the text editor, the file is not recompiled.)
If an error occurs in revising a piping assembly, the system invokes the editor automatically to
give you an opportunity to correct the problem.
4. You can select other files to edit or select exit to return to the data management form.

Delete Piping Assembly Data


This option enables you to delete a PAL module or set of PAL modules from the Piping Assembly
Library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the PAL files to be listed.

Operating Sequence
1. Select the Delete option.

The system displays the table files in the active library.

Plant Design System (PDS) Reference Data Manager (PD_Data)

391

Piping Assembly Library

2. Select Module for Deletion


Select the modules to be deleted from the list of modules. You can use the scroll bar to scroll
through the available files.
3. Accept or Select Other Option
Accept the modules and begin processing.

The system deletes the modules from the Piping Assembly Library.

Report Assembly Data


This option enables you to create a list file of all the PAL modules in the Piping Assembly Library.

Operating Sequence
1. Select the Report option from the Data Management form.

2. Revise Report Parameters


Key in the file information for the location of the report file to be created.
3. Select Print or Print/Save.

392

Plant Design System (PDS) Reference Data Manager (PD_Data)

Piping Assembly Library


Then select the print queue from the list of displayed queues. Refer to the section on Plot
and Print Queues in the Project Administrator Reference Guide for information on setting up
multiple print queues.
If you select the Print/Save option, the system will create a file named assemblies in the
default source file location.
4. Accept to Form Report
Select Accept to create the specified report file.

List Assembly Data


This option displays all the PAL modules for the Piping Assembly Library.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the PAL modules to be listed.

Operating Sequence
1. Select the List option.

The system displays the PAL modules in the Piping Assembly Library.

2. You can use the scroll bar to scroll through the available files.
3. Select Cancel to exit the form.

Plant Design System (PDS) Reference Data Manager (PD_Data)

393

Piping Assembly Library

Extract Assembly Data


This option enables you to extract an PAL module out of the Piping Assembly Library for editing or
printing.

Before Using This Command


Set the toggle to Full List or Sub-string to determine the PAL files to be listed.
Define the node name and path for the location of the PAL files in the Default Project Control
Data or using the fields at the bottom of the Assembly Data Management form.

Operating Sequence
1. Select Extract from the Data Management form.

2. Select Assembly for Extraction


Select the modules from the list of files and select Accept. You can use the scroll bar to
scroll through the available files.

The system pulls the files out of the library and places them in the default directory specified
in the Project Control Data. The system also writes the names of the extracted files to a file
named PD_pal_list.
If the list file is less than 24 hours old, the system appends the entries to the file; otherwise, it
overwrites the file.

394

Plant Design System (PDS) Reference Data Manager (PD_Data)

SECTION 16

Reference Database Revision Manager


This command creates a set of reports used to coordinate revisions in the Reference Database
and the implied changes which are required in the model. Each of the four reports listed is created
in the directory for the applicable model.
Creation of any of these reports also generates a summary report. The summary report is created
and named according to user-specified information provided on the Reference Database
Revision Manager form. Selecting the option to print the summary report will also force the
printing of the individual report that initiated the creation of the summary report.

Reference Data Conflict Report (on page 397) - Creates a report of piping or instrument
components (including piping and tubing) in any model within the project that have any
specification data that is in conflict with the appropriate Piping Commodity Data, Piping Specialty
Data, or Instrument Data of the Material Reference Database. The RDB Conflict Report file has
an extension of .rpt and is created in the model directory as <model_number>.rpt.
Refer to the section titled Summary of Report Parameters and Discrepancy Hierarchy
found at the beginning of this chapter for information on the order of significance of reported
problems.
You should run this report when segment data or RDB data (such as in the Piping Job
Specification Database, the Piping Job Spec Tables, and the Physical Dimension Tables) have
been changed and you want to determine which components need to be reconstructed or updated
from the RDB.
Table Change Report (on page 401) - Creates a report of all piping or instrument components
(including pipes) in any model within the project that are affected by a change to a specific table for
a specific input or set of inputs. Both geometric changes as a result of revisions to dimension

Plant Design System (PDS) Reference Data Manager (PD_Data)

395

Reference Database Revision Manager


tables and changes in weight data as a result of revisions to weight tables are reported. The
Table Change Report file has an extension of .tcr and is created in the model directory as
<model_number>.tcr.
If your project was created with PDS version 6.0, use the Reference Data Conflict
Report instead.
Reference Data Impact Report (on page 407) - Creates a report, based on user-defined search
criteria, of the effects of modifying individual component attributes in the current approved RDB.
The RDB Impact Report file has an extension of .imp and is created in the model directory as
<model_number>.imp.
Proposed RDB Changes Report (on page 410) - Creates a single report assessing the effect of
multiple changes in the unapproved Material Reference Database. The Proposed RDB Changes
Report file has an extension of .pcs and is created in the model directory as
<model_number>.pcs. This report does not update the model.
Scheduled Reference Data Conflict Report - This is the same report as the Reference Data
Conflict Report (on page 397) except that you can schedule the report to run on a regular basis
using Batch Services.

Field Descriptions
Report Node Specifies the node on which the summary report will be created.
Report Path Specifies the directory in which the summary report will be created.
Report Name Specifies the name that will be used for the summary report file.
Print/Delete This option deletes the summary report after it is printed. Selecting this option
activates the queue pick list which allows you to select the appropriate print queue.
Print/Save This option does not delete the summary report after it is printed. Selecting this
option activates the queue pick list which allows you to select the appropriate print queue.
Save Saves the report in the model directory, and saves the summary report in the
user-specified directory. This option does not print the summary report.

Summary of Report Parameters and Discrepancy Hierarchy


The following chart summarizes some of the parameters used in the processing and creation of
the reports available from this command:

Discrepancies are reported according to the significance of the problem they represent. In all
cases, the most severe problem will be the problem that is reported. The hierarchy of the
problems reported is as follows:
1. Item not found in the spec.

396

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


2. Dimension tables have changed.
3. Discrepancy between component connect point NPD and segment NPD.
4. Discrepancy between model and RDB for any of the following attributes:
end preparation - green

commodity code

pressure rating - green

model code

schedule/thickness - green

modifier

table suffix - green

geometric industry standard

end preparation

weight code

pressure rating - red

fabrication category

schedule/thickness - red

materials grade

table suffix - red


5. Weight tables have changed.

Reference Data Conflict Report


This option creates a report of piping or instrument components (including piping and tubing) in
any model within the project that have any specification data that is in conflict with the appropriate
Piping Commodity Data, Piping Specialty Data, or Instrument Data of the Material Reference
Database. The output file for this report has an extension of .rpt.
This command is used to coordinate between revisions in the Reference Database and the
implied changes which are required in the model. It also reports piping and instrument
components that require reconstruction or recalculations as a result of piping segment data
changes in the model.
The Reconstruct Component command is required for any component which has geometric
type specification data revised.
The Update from Reference Database command is required for any component which has
non-geometric specification data (such as commodity code or weight table) revision.
The Re-Compute Thickness command is required for any component which has been
reported as requiring calculations as a result of changes in the material tables or thickness
tables.
You can use the Review Reference Database Revision Management Report command to
review any component in the model requiring reconstruction or an update of the specification data
as a result of changes to the Material Reference Database. This command allows you to review
any component in the model requiring reconstruction or replacement as a result of RDB changes
or deletions from the Material Reference Database. In support of this review capability, an indexed
file, the RDB Revision Management Component List, is created in the same directory as the
model with the name <model_number>.rdb. Refer to the Piping Design Graphics Reference
Guide for more information on this command.
Any component, previously reported as having required reconstructing or updating, which has
been deleted from the model, will not be included in any future reports or in the RDB Revision
Management Component List. Likewise, the RDB Revision Management Component List will be
automatically compressed as part of the report creation process.
The system will not report a component as requiring reconstruction or updating from the RDB
solely on the basis of the requirement to reconstruct flag being set for the piping segment
associated with that component. The Reference Data Conflict Report will clear the requirement

Plant Design System (PDS) Reference Data Manager (PD_Data)

397

Reference Database Revision Manager


to reconstruct (or recalculate) flag if it determines there are no discrepancies for the component
associated with that piping segment.
The system will not report a component as requiring reconstruction or updating from the RDB as
the result of changing any attributes of an Implied Item.

Before Using This Command


You should not access any piping model for an interactive design session while a Reference
Database Revision Management report is being created.

Processing
Piping Commodities
The system extracts the following data from the model for the purpose of reading piping
commodity specification data from the Material Reference Database. This is the same data that
is used for the placement or reconstruction of a piping commodity.
piping materials class

second size

commodity name

option code

first size
maximum temperature
The first size and second size are determined from the piping segment data and not from the
component itself.
If the piping commodity in the model is a branch that was initially placed using a branch table from
the Reference Database, the system reads the appropriate branch table from the Piping Materials
Class data to determine if there has been a change in the commodity name for the branch. If so,
this component is flagged as requiring reconstruction.
The system compares the following data for consistency between the model and the Reference
Database for piping commodities. The data which may impact the geometry and/or the
symbology in the model is designated by an asterisk.
* end preparation - green

* commodity code

* pressure rating - green

* model code

* schedule/thickness - green

* modifier

* table suffix - green

* geometric industry standard

* end preparation - red

weight code

* pressure rating - red

fabrication category

* schedule/thickness - red

materials grade

* table suffix - red


Note that user overrides of fabrication category and schedule/thickness will not be included in the
report.
The system compares the gasket thickness for each bolted end of a piping commodity with the
gasket separation in the corresponding Piping Materials Class data. If a value is defined in the
Reference Database, the gasket thickness at the bolted end is compared with that value. If a
Gasket Separation Table name is defined, that table is used to determine a gasket separation
value for comparison with the gasket thickness at the bolted end.
When a component is placed next to an integral gasket, the gasket thickness is set to zero
in the model. As a result, the Reference Data Conflict Report may report a gasket thickness

398

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


error for such components. The report compares the component gasket thickness in the model (0)
with the component gasket thickness defined in the reference data, which may be different from 0,
without considering the mating component data. Such errors should be ignored.
The system compares the NPD at each connect point of the component with the NPD of the
segment.
The system compares the schedule thickness data for a component in the model to the
corresponding data in the Material Reference Database. The comparison will consider the
following issues at a minimum:
the application of the schedule/override in the model.
changes to the value for the schedule thickness in the Piping Commodity Data within the
Material Reference Database.
changes to the joint efficiency value in the Piping Commodity Data within the Material
Reference Database.
changes to the value for the thickness equation in the Piping Materials Class Data within the
Material Reference Database.
changes to the Thickness Data Table or the Materials Data Table.

Refer to the section titled Summary of Report Parameters and Discrepancy Hierarchy
found at the beginning of this chapter for information on the order of significance of
reported problems.
The RDB Conflict Report does not identify discrepancies between taps placed in the
model and the RDB Tap Properties Data tables used to place the taps.

Piping Specialties and Instruments


The system extracts the component number from the model for the purpose of reading piping
specialty and instrument specification data from the Material Reference Database. The
component number is also used for the placement or reconstruction of a piping specialty or an
instrument. For example, instrument_comp_no is used for instruments, and piping_comp_no is
used for piping specialties.
The system compares the following data for consistency between the model and the Reference
Database for piping specialties and instruments. The data which may impact the geometry
and/or the symbology in the model is designated by an asterisk.
* end preparation - green

* physical data id

* pressure rating - green

* model code

* schedule/thickness - green

* modifier

* table suffix - green

* geometric industry standard

* end preparation - red

weight code

* pressure rating - red

fabrication category

* schedule/thickness - red

materials grade

* table suffix - red


The system compares the gasket thickness for each bolted end of a piping specialty or instrument
with the gasket separation in the corresponding Piping Materials Class data. If a value is defined
in the Reference Database, the gasket thickness at the bolted end is compared with that value. If
a Gasket Separation Table name is defined, that table is used to determine a gasket separation
value for comparison with the gasket thickness at the bolted end.

Plant Design System (PDS) Reference Data Manager (PD_Data)

399

Reference Database Revision Manager


The system compares the green specification data in the Reference Database with all connect
points for that component in the model which are designated as having green connect point
properties.
The system compares the red specification data in the Reference Database with all connect
points, if any, which are designated as having red connect point properties.
The system compares the schedule thickness data for a component in the model to the
corresponding data in the Material Reference Database. The comparison will consider the
following issues at a minimum:
the application of the schedule/override in the model.
changes to the value for the schedule thickness in the Piping Commodity Data within the
Material Reference Database.
changes to the joint efficiency value in the Piping Commodity Data within the Material
Reference Database.
changes to the value for the thickness equation in the Piping Materials Class Data within the
Material Reference Database.
changes to the Thickness Data Table or the Materials Data Table.
The RDB Conflict Report does not identify discrepancies between taps placed in the
model and the RDB Tap Properties Data tables used to place the taps.

Operating Sequence
1. Select the Reference Data Conflict Report option.

The system activates the Reference Data Conflict form.

2. Select the extent of the project to be processed.


Project process all piping models for the entire project.
Piping Design Area process the selected piping design areas.
Models process the selected models within a selected design area.

400

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


3. You can key in changes to the Report Node, Report Path, and Report Name for the
summary report output or use the default location and name.
The default location for the summary report is determined by the Report Management Data
of the Report Manager.
4. Select the desired output method for the summary report: Print/Delete, Print/Save, or Save.
If you will be printing the summary report, select a queue from the pick list.
5. Accept to Submit Job, Restart or Exit
Set the toggle to Submit Immediately or select Delayed Submit and fill in the day and time
to process the request.
6. Select Accept to submit the request for processing.

The system submits the request to the batch queue PDreport. It updates the batch log file
periodically to include a list of piping models which have been processed. The Reference
Data Conflict report file has an extension of .rpt and is created in the model directory
as<model_number>.rpt . If the summary report is printed as a result of creating this report,
this report will also be printed.

Table Change Report


This option creates a report of all piping or instrument components (including pipes) in any model
within the project that are affected by a change to a specific table for a specific input or set of
inputs. Both geometric changes as a result of revisions to dimension tables and changes in weight
data as a result of revisions to weight tables are reported. The output file for this report has an
extension of .tcr.
This report should be used only in the following situation:
The RBD was revised and you did not reconstruct the affected components. Then you
upgraded the project to PDS version 6.0, at which time all components were updated to have
the new last_placed_date attribute set to the date the upgrade occurred.
You will need to know the date the RDB was modified in order to find which components
require reconstruction as a result of the RDB change. This report may return false
discrepancies because it will include those items that were placed after the RDB was
changed.
In short, we recommend using this report only when the RDB is changed prior to upgrading to
PDS version 6.0, and affected components have not been reconstructed to reflect the RDB
change.
The Reconstruct Component command is required for any component which has a dimension
table revised and the Update from Reference Database command is required for any
component which has a weight table revised.

Processing
The system performs a virtual component placement for each component in a piping model (in a
manner similar to that used by the Table Checker) to determine if that component has had any of
its geometric or weight data derived from the specified tables. The system searches all piping and
instrument components in all piping models within the project for the use of such tables and
creates a report.
In searching the model for components that have dimensional and weight data derived from the
list of revised tables, the first size and second size are determined from the components data - not
the piping segment data. This is due to the fact that reconstruction of the component will be

Plant Design System (PDS) Reference Data Manager (PD_Data)

401

Reference Database Revision Manager


required, if the nominal piping diameter of any segment associated with the component differs
from the corresponding connect point size.
The contents of this report include the following data, which is sorted by the piping model number
and the line id within each piping model.
piping model number
line id
component number (if applicable)
commodity name (if applicable)
model code
dimension or weight tables
The title page for the report will include the sub-title, Table Change Report.
Piping specialties and instruments are excluded from this report when the specification data and
the geometry data have been defined by the user (not defined in the Reference Database).
You can use the Review Reference Database Revision Management Report command to
review any component in the model requiring reconstruction or updating as a result of the
components geometric or weight data being changed by a table revision. In support of this review
capability, the system creates an indexed file, the RDB Revision Management Component List, in
the same directory as the model with the name <model_number>.rdb. Refer to the Piping Design
Graphics Reference Guide for more information on the Review Reference Data Revision
Report command.
Any component, previously reported as needing reconstructing or updating, which has been
deleted from the model, will not be included in any future reports or in the RDB Revision
Management Component List. Likewise, the RDB Revision Management Component List will be
automatically compressed as part of the report creation process.
Piping and instrument components in any model which do not have a corresponding record in the
applicable table of the Piping Design Database are ignored and excluded from the report. These
components, if any, are reported through the Database Verification command of the Project
Administrator.

Operating Sequence
1. Select the Table Change Report option.

402

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


The system displays a list of Physical Data Libraries.

2. Select Table Library


Select the Physical Data Library to process, such as U.S. Practice, DIN, or Company Practice
and select Accept.
3. Enter Date for Search ( dd-mmm-yy )
Key in a date (such as 10-Aug-95) in the Revision Date field to list all the tables that have
been revised since the specified date.
4. Accept, Re-enter Date or Choose Extent
Set the toggle to Full List or Sub-String. For Sub-String, key in a string to limit the tables to
be listed.
THEN
Select Accept to begin processing.

Plant Design System (PDS) Reference Data Manager (PD_Data)

403

Reference Database Revision Manager


The system displays a list of all dimension and weight tables (or those which match a specified
substring).

5. Select Tables or Exit


Select the dimension tables to be considered in the creation of the revision management
report.
OR
You can select Process All to process all the listed tables (those which meet the specified
revision date and substring).
THEN
Select Accept to process the selected tables.

404

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


For each of the selected tables, the system displays the table data in the Table Data Display
form.

6. Select Table Entry


For each table, you can specify which entries (up to a total of 200 entries) in the table have
been revised.

Plant Design System (PDS) Reference Data Manager (PD_Data)

405

Reference Database Revision Manager


Although the performance of the Reference Data Manager in creating the report will not be
impacted by the number of dimension table entries that are to be considered for revision
management, the list of components in the model will be impacted. For example, if you
inadvertently identify entries which had not actually changed, you may create significant,
unnecessary work.

7. Select the extent of the project to be processed.


Project process all piping models in the entire project.
Piping Design Area process the selected piping design areas.
Models process the selected models within a selected design area.

The summary report path and report node are determined by the settings defined with the
Report Manager.
8. You can change the location or name for the summary report output or use the defaults.
9. Select the desired output method for the summary report: Print/Delete, Print/Save, or Save.
10. Accept to Submit Job, Restart or Exit
Set the toggle to Submit Immediately or select Delayed Submit and fill in the day and time
to process the request.
11. Select Accept to begin processing the request.

The system submits the request to the batch queue PDreport. It updates the batch log file
periodically to include a list of piping models which have been processed. The table change
report file has an extension of .tcr and is created in the model directory as
<model_number>.tcr . If the summary report is printed as a result of creating this report, this
report will also be printed.

406

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager

Reference Data Impact Report


Selecting the Reference Data Impact Report command activates the Search Criteria form.

This report is based on user-defined search criteria of attributes such as piping materials class,
commodity code, commodity name, option code, maximum temperature, nominal diameter, end
preparation, schedule thickness, table suffix, and so forth. The purpose of this report is to find
which components (constrained by your search criteria) will be impacted by a change in the
attributes as they exist in the current approved RDB. The RDB Impact Report search criteria are
valid for Piping Material Class Data (pdtable_201) and Piping Component Specification Data
(pdtable_202).
The RDB Impact Report file has an extension of .imp and is created in the model directory as
<model_number>.imp. This report does not include a graphical review capability.

Example 1
As an example, assume that you want to know the impact of changing the vendor for a specific
type of valve. You could define the search criteria to find all instances of valves with that specific
geometric industry standard that would need to be reconstructed if the vendor were changed.

Example 2
As a second example, assume that you are working with a project that uses spec A and spec B.
Both of these specs contain the value X, for the vendor of gate valves. A model has been created
that uses both spec A and B, and valves have been placed from both of these specs.
Also, assume that spec B has been modified since the valves have been placed so that the vendor
in spec B now has a value of Y (instead of X), and the model has not been updated to reflect this
spec change.

Plant Design System (PDS) Reference Data Manager (PD_Data)

407

Reference Database Revision Manager


If the Reference Data Impact Report was run now to determine the impact of changing the vendor
X, the system would scan the RDB for all occurrences of vendor X (which, at this time, would be
only those placed from spec A), check the portions of the design you specified for occurrences of
vendor X, then report the matching occurrences back to you.
The resulting report would not list those valves from vendor X that were placed from spec B,
because the occurrences of those valves in the model did not match the occurrences in the RDB
(due to the model not being updated after the spec change).

Operating Sequence
1. Select the Reference Data Impact Report command from the Reference Data Revision
Manager form.

The system activates the Search Criteria form, which prompts you to select the attribute to be
restricted.
2. Select Attribute
Select the attribute to be restricted.

After selecting attribute from the attribute display list, the system displays the selected
attribute in a separate field and displays a list of operators.

3. Select Operator
Select an operator to define the search criteria.

The system displays the selected operator and prompts you to key in an attribute value.
4. Enter Attribute Value
Key in the attribute value. For a sub-string search, key in a string to appear anywhere within
the attribute value (do not use wild cards).
If the attribute is code-listed, the system displays a list of values from the Standard Note
Library.
5. Select the value and select Accept.

The system validates the input and displays the defined search criteria in the Search Criteria
display field.
6. Accept or Select And/Or Operator

Select AND to specify an additional condition or select OR to specify an alternative condition.


OR
Accept the defined search criteria and activate the Reference Data Revision Manager form.

408

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager

7. Revise the search criteria, if necessary, using the Revise Search Criteria option.
OR
Select the extent of the project to be processed.
Project Process all piping models for the entire project.
Piping Design Area Process the selected piping design areas.
Models Process the selected models within a selected design area.
8. You can key in changes to the Report Node, Report Path, and Report Name for the
summary report output or use the default location and name.
The default location for the summary report is determined by the Report Management Data
of the Report Manager.
9. Select the desired output method for the summary report: Print/Delete, Print/Save, or Save.
If you will be printing the summary report, select a queue from the pick list.
10. Accept to Submit Job, Restart or Exit
Set the toggle to Submit Immediately or select Delayed Submit and fill in the day and time
to process the request.
11. Select Accept to submit the request for processing.

The system submits the request to the batch queue PDreport. It updates the batch log file
periodically to include a list of piping models which have been processed. The reference data
impact report file has an extension of .imp and is created in the model directory as
<model_number>.imp . If the summary report is printed as a result of creating this report,
this report will also be printed.

Plant Design System (PDS) Reference Data Manager (PD_Data)

409

Reference Database Revision Manager

Proposed RDB Changes Report


This command creates a report assessing the impact of multiple changes in the unapproved RDB.
Selecting this command from the Reference Data Revision Manager form activates the
Proposed RDB Changes Report form.
You must make changes to the unapproved Material Reference Database in order to
assess the effect of these changes. You are responsible for restoring the unapproved Material
Reference Database to its original state if you decide not to pursue these changes.
Refer to the section titled Summary of Report Parameters and Discrepancy Hierarchy
found at the beginning of this chapter for information on the order of significance of reported
problems.

Piping Commodities
The system extracts the following data from the model for the purpose of reading piping
commodity specification data from the Material Reference Database. This is the same data that is
used for the placement or reconstruction of a piping commodity.
piping materials class

second size

commodity name

option code

first size
maximum temperature
The first size and second size are determined from the piping segment data and not from the
component itself.
If the piping commodity in the model is a branch that was initially placed using a branch table from
the Reference Database, the system reads the appropriate branch table from the Piping Materials
Class data to determine if there has been a change in the commodity name for the branch. If so,
this component is flagged as requiring reconstruction.

410

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager


The system compares the following data for consistency between the model and the Reference
Database for piping commodities. The data which may impact the geometry and/or the symbology
in the model is designated by an asterisk.
* end preparation - green

* commodity code

* pressure rating - green

* model code

* schedule/thickness - green

* modifier

* table suffix - green

* geometric industry standard

* end preparation - red

weight code

* pressure rating - red

fabrication category

* schedule/thickness - red

materials grade

* table suffix - red


Note that user overrides of fabrication category and schedule/thickness will not be included in the
report.
The system compares the gasket thickness for each bolted end of a piping commodity with the
gasket separation in the corresponding Piping Materials Class data. If a value is defined in the
Reference Database, the gasket thickness at the bolted end is compared with that value. If a
Gasket Separation Table name is defined, that table is used to determine a gasket separation
value for comparison with the gasket thickness at the bolted end.
The system compares the specification data for any connect point of a piping commodity which
has been designated as a tap with the appropriate data (either the specification data from the Tap
Properties Data in the Reference Database or from another connect point.
The system compares the NPD at each connect point of the component with the NPD of the
segment.
The system compares the schedule thickness data for a component in the model to the
corresponding data in the Material Reference Database. The comparison will consider the
following issues at a minimum:
the application of the schedule/override in the model.
changes to the value for the schedule thickness in the Piping Commodity Data within the
Material Reference Database.
changes to the joint efficiency value in the Piping Commodity Data within the Material
Reference Database.
changes to the value for the thickness equation in the Piping Materials Class Data within the
Material Reference Database.
changes to the Thickness Data Table or the Materials Data Table.
Refer to the section titled Summary of Report Parameters and Discrepancy Hierarchy
found at the beginning of this chapter for information on the order of significance of reported
problems.

Piping Specialties and Instruments


The system extracts the component number from the model for the purpose of reading piping
specialty and instrument specification data from the Material Reference Database. The
component number is also used for the placement or reconstruction of a piping specialty or an
instrument. For example, instrument_comp_no is used for instruments, and piping_comp_no is
used for piping specialties.

Plant Design System (PDS) Reference Data Manager (PD_Data)

411

Reference Database Revision Manager


The system compares the following data for consistency between the model and the Reference
Database for piping specialties and instruments. The data which may impact the geometry
and/or the symbology in the model is designated by an asterisk.
* end preparation - green

* physical data id

* pressure rating - green

* model code

* schedule/thickness - green

* modifier

* table suffix - green

* geometric industry standard

* end preparation - red

weight code

* pressure rating - red

fabrication category

* schedule/thickness - red

materials grade

* table suffix - red


The system compares the gasket thickness for each bolted end of a piping specialty or instrument
with the gasket separation in the corresponding Piping Materials Class data. If a value is defined
in the Reference Database, the gasket thickness at the bolted end is compared with that value. If
a Gasket Separation Table name is defined, that table is used to determine a gasket separation
value for comparison with the gasket thickness at the bolted end.
The system compares the specification data for any connect point of a piping specialty or
instrument which has been designated as a tap with the appropriate data, i.e. either the
specification data from the Tap Properties Data in the Reference Database or from another
connect point. Piping specialties and instruments are excluded from this report when the
specification data and the geometry data is defined by the user (not defined in the Reference
Database).
The system compares the green specification data in the Reference Database with all connect
points for that component in the model which are designated as having green connect point
properties.
The system compares the red specification data in the Reference Database with all connect
points, if any, which are designated as having red connect point properties.
The system compares the schedule thickness data for a component in the model to the
corresponding data in the Material Reference Database. The comparison will consider the
following issues at a minimum:
the application of the schedule/override in the model.
changes to the value for the schedule thickness in the Piping Commodity Data within the
Material Reference Database.
changes to the joint efficiency value in the Piping Commodity Data within the Material
Reference Database.
changes to the value for the thickness equation in the Piping Materials Class Data within the
Material Reference Database.
changes to the Thickness Data Table or the Materials Data Table.

Operating Sequence
1. Select the Proposed RDB Changes Report option.

The system activates the Proposed RDB Changes form.

412

Plant Design System (PDS) Reference Data Manager (PD_Data)

Reference Database Revision Manager

2. Select the extent of the project to be processed.


Project process all piping models for the entire project.
Piping Design Area process the selected piping design areas.
Models process the selected models within a selected design area.
3. You can key in changes to the Report Node, Report Path, and Report Name for the
summary report output or use the default location and name.
The default location for the summary report is determined by the Report Management Data
of the Report Manager.
4. Select the desired output method for the summary report: Print/Delete, Print/Save, or Save.
If you will be printing the summary report, select a queue from the pick list.
5. Accept to Submit Job, Restart or Exit
Set the toggle to Submit Immediately or select Delayed Submit and fill in the day and time
to process the request.
6. Select Accept to submit the request for processing.

The system submits the request to the batch queue PDreport. It updates the batch log file
periodically to include a list of piping models which have been processed. The proposed
RDB changes report file has an extension of .pcs and is created in the model directory as
<model_number>.pcs. If the summary report is printed as a result of creating this report,
this report will also be printed.
Reference Data Conflict Report (on page 397)
Proposed RDB Changes Report (on page 410)

Plant Design System (PDS) Reference Data Manager (PD_Data)

413

SECTION 17

MicroStation V7 Checker
As PDS projects do not support MicroStation V8 design files, you can use MicroStation V7
Checker to find any MicroStation V8 design files in a project. MicroStation V7 Checker generates
an ASCII-based log file at a user-defined location that provides a report on the files contained in
the project. You can then remove any MicroStation V8 files from the project.
If PDS finds a MicroStation V8 design file, this error message displays:

If there are any V8 design files in a project, the software may crash or produce
unusual errors.
To locate the problem file(s) in the project:
1. Enter the following:
File name - Specifies the name of the text file to generate.
Directory - Type the path where to create the file.
Node name - Type the computer name on which to create the log file.

The log file is generated at the specified location.


2. Open the file using any ASCII text editor to view a report on the project files. For any
MicroStation V8 files, the message, "Unsupported V8 file found in the path..." displays.

Plant Design System (PDS) Reference Data Manager (PD_Data)

415

SECTION 18

Verify RDB Library


For releases prior to the 4.2 PDS release, a problem existed in the Reference Data Manager, such
that the binary tree structure in a reference data library (such as the Graphic Commodity Library)
could be corrupted without the user immediately detecting any problems with that library.
Although the software problem was corrected in the 4.2 PDS release, the data problem that
resulted may have persisted beyond that release, particularly if the library has not been
compressed.
As a final step within the project upgrade process, the system verifies the integrity of the binary
tree structure within each of the reference data libraries. If an error is detected, a specific
warning message will be reported, both interactively and in the upgrade log. In this event, you
should contact Intergraph immediately for assistance in repairing the library.
The Verify RDB Library utility has been provided to allow the capability to verify the integrity of
the binary tree structure on demand.
The Verify RDB Library icon is located in the PD_Shell program group on systems upon which
the PD_Data software has been loaded locally; double-click on this icon to activate the command.

Operating Sequence
1. Execute the command by double-clicking on the Verify RDB Library icon in the PD_Shell
program group.

The system activates the Reference Database Library Verification Utility form, and prompts
you to select the appropriate project number from the list.

Plant Design System (PDS) Reference Data Manager (PD_Data)

417

Verify RDB Library

2. Select the desired project number, and then select the Verify Reference Database Library
command.

The system begins the verification process and displays the Verifying RDB Library Files
message. When processing is complete, the system returns a message similar to the one
shown below:

A typical output file has been excerpted below. No errors were found in this example.
Opening : /onneso3a/rdb/lib/approved/618pjstb.l
header number keys = 234
tree number keys = 234
Opening : /onneso3a/rdb/lib/approved/618pjstb.l.t
header number keys = 234
tree number keys = 234
Opening : /onneso3a/rdb/lib/approved/618pjstb.l.r
header number keys = 234
tree number keys = 234

418

Plant Design System (PDS) Reference Data Manager (PD_Data)

Verify RDB Library


Opening : /onneso3a/rdb/lib/approved/618shbom.l
header number keys = 2877
tree number keys = 2877
Opening : /onneso3a/rdb/lib/approved/618lgbom.l
header number keys = 2629
tree number keys = 2629
Opening : /onneso3a/rdb/lib/approved/618spbom.l
Empty file, no keys.
Opening : /onneso3a/rdb/lib/approved/618note.l
header number keys = 4162
tree number keys = 4162
Opening : /onneso3a/rdb/lib/approved/618note.l.t
header number keys = 65
tree number keys = 65
Counting implied keys for code31
Counting implied keys for code35
Counting implied keys for code36
Counting implied keys for code37
Counting implied keys for code50
Counting implied keys for code69
Counting implied keys for code125
.
.
.
Counting implied keys for code2000
Opening : /onneso3a/rdb/lib/approved/618label.l
header number keys = 217
tree number keys = 217
Opening : /onneso3a/rdb/lib/approved/618assem.l
header number keys = 110
tree number keys = 110
Opening : /onneso3a/rdb/lib/approved/618assem.l.t
header number keys = 110
tree number keys = 110
Opening : /onneso3a/rdb/lib/approved/618gcom.l
header number keys = 1509
tree number keys = 1509
Opening : /onneso3a/rdb/lib/approved/618gcom.l.t
header number keys = 1509
tree number keys = 1509
Opening : /onneso3a/rdb/lib/approved/618pcdim.l
header number keys = 4820
tree number keys = 4820
Opening : /onneso3a/rdb/lib/approved/618pcdim.l.t
header number keys = 4820
tree number keys = 4820
Opening : /onneso3a/rdb/lib/approved/618pcdim.l.r
header number keys = 4820
tree number keys = 4820
Total files with errors : 0

Plant Design System (PDS) Reference Data Manager (PD_Data)

419

APPENDIX A

Appendix: Reference Data Manager Error


Messages
The PDS 3D products share common message files contained in the win32app\ingr\pdshell\msg
directory.
pdsmc.msg command field messages
pdsme.msg error and warning messages
pdsmp.msg prompts and messages
pdsms.msg status messages.

Plant Design System (PDS) Reference Data Manager (PD_Data)

421

APPENDIX B

Appendix: Codelists
This section details the codelists used in PDS.
The data contained within this appendix is for informational purposes only and may not
exactly match the codelists delivered with the product.

General Comments
Codelist sets in this document define the values for all codelisted attributes used in the PDS Piping
Task which are specific to US plant design practices.
You can add, delete, or revise codelist sets to reflect your own practices, terminology, and
language. A task user, however, cannot revise a codelist set from a work session. Revisions to a
codelist set, can only be made in the General RDB or Standard Note Library.
In listings that follow, the maximum number of entries that may be expected for a specific codelist
set is shown in parentheses following the name of the codelist set.
For PDS users that wish to modify codelist files delivered with the PDS software to reflect their
own practices, two approaches are possible:
Make the modifications within the range of codelist numbers defined in the codelist library
delivered with the PDS software. This has the advantage of resulting in the best organized set
of codelisted definitions. The disadvantage is that numbers added by the user may conflict
with numbers added in future versions of software.
Increase the maximum number of entries allowed for the codelist set and make additions to it
in the range of extended numbers. This will minimize possible conflicts assigned numbers but
will require compiling of the codelists and of the associated databases.
Values enclosed in brackets [ ] in pages that follow represent descriptive information. The values
stored in the codelist sets will exclude this bracketed information from the codelist descriptions.
The net length of a codelist entry cannot exceed 50 characters. Other considerations may,
however, require that a shorter description be made. For example:
For the P&ID Task, the total compressed length of a label part can not exceed 36 characters.
The formats of specification type reports for the Instrument Task require that applicable
codelist descriptions do not exceed 25 characters.

Comments Specific to Units of Measure Codelist Sets


The PDS system of units is derived from the 1980 Edition of API-2564, Manual of Petroleum
Measurement Standards, Chapter 15 "Guidelines for the Use of the International System of Units
(SI) in the Petroleum and Allied Industries".
The tables in this document include the following information.
Codelist set

This is the number of the codelist set that identifies a specific


quantity. For example, codelist set 1028 includes the units of
measure that apply to the quantity "mass".

Codelist no

This is the number that defines a specific unit of measure within a


codelist set. For example, codelist number 1 in codelist set 1028
refers to the "lb" units of measure.

Plant Design System (PDS) Reference Data Manager (PD_Data)

423

Appendix: Codelists
Unit type

This code is not explicitly shown in the tables. The unit type equals
the number of the codelist set minus 1000. For example, reference
to unit type 28 refers to "mass".

Quantity name

Entries in this column define the quantity whose units of measure


are being defined.

Unit name

Several unit names are provided for a given codelist set. Any of
these names can be used to define the quantity.

Conversion to destination
unit

Two sets of columns define the conversion of variables expressed


in the units shown under the column "Unit Name" to the unit shown
under the column "Destination Unit". The following explanations
apply:

The column captioned Destination Unit defines the unit to


which the unit included under the column Unit Name will be
converted using the value shown under the column Factor.

The column captioned Factor provides the actual conversion


factor to be used for the conversion. For example, in codelist
set 1028, to convert a mass measurement in "lb" to "kg",
multiply the value in the former units by the conversion factor,
4.535 924 E-01. In some cases, such as temperature,
summation may also be required to effect the desired
conversion. All conversion factors are taken or derived from
API Publication 2564. Groups of three digits are separated by
spaces with no commas. For example,
3.048 000 E-01 = 3.048 000 x 10-1 = 0.3048000.
Similarly,
9.290 304 E+02 = 9.290 304 x 102 = 929.0304.

An asterisk (*) indicates that all following digits are zeros. If a


conversion factor happens to end in several zeros but does not
have an asterisk, any subsequent digits would not necessarily be
zeros. Most of the conversion factors are shown to six or seven
significant figures. Those shown to fewer than six significant
figures are limited by the precision of the known or determinable
value of a physical property, such as the density of distilled water
at a reference temperature.
Conversion to first unit in
CL

Two sets of columns define the conversion of the units shown


under the column Unit Name to the first unit shown in that column.
The conversion is done per the equation:
y= A + Bx
where,
x applies to the value of the variable expressed in the units shown
in the column captioned Unit Name.
y applies to the value of the variable expressed in the units shown
in the first line of the column captioned Unit Name.
A is the factor in the column captioned Factor A.
B is the factor in the column captioned Factor B.

424

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
The distinction between upper case and lower case symbols is very important. For example:
K= kelvin
k= kilo= 103
M= mega= 106
m= milli= 10-3 (when m is used as a prefix)
m= metre (when m is used alone)
N= newton
n= nano= 10-9
In editing any of the codelist sets for units, do not change the meaning of existing codelist values.
In all codelist sets for units, a blank space is provided as the first character in the unit name. The
blank space is used to silence the units in the formation of labels.
Nomenclature:
Symbol

Name

Quantity

bar

bar

pressure

degC

degree Celsius

temperature

gram

mass

kg

kilogram

mass

metre

length

min

minute

time

Pa

pascal

pressure

metric ton

mass

CL31, Object Types for Orthographic Drawings (40)


C31 DF=WRK_DD_CODLST:CODE0031.ENT MAX=999
0031, Object Types for Orthographic Drawings (40)
Equipment Category Object Types (100-149)
The Range of 100-149 for the equipment category is
divided into two parts:
101-110 These entries are reserved by INTERGRAPH
and may not be changed by the user.
111-149 Codelist entries in this range may be created,
revised, and/or deleted by the user.
If modified the user must also revise the
contents of the file eqp_object.dwg and
labels.xxx (where xxx is the drawing type
number defined in CL2000 ) in the project
directory.

Plant Design System (PDS) Reference Data Manager (PD_Data)

425

Appendix: Codelists
101
110
120
124
128
130
135
140

=
=
=
=
=
=
=
=

Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment

Group
Nozzle
Platform
Handrail
Penetration
Stair
Ladder
Davit

Piping Category Object Types (200-249)


205
207
210
215
220

=
=
=
=
=

Piping
Pipe
Piping
Piping
Piping

Segment
Component
Specialty
Support

Instrument Category Object Types (250-279)


250
252
255
260

=
=
=
=

Control Valves and Regulators


Relief Devices
Other In-Line Instruments
Off-Line Instruments

HVAC Category Object Types (359-399)


359
360
361
362
363
364
365
366
367
368
369
370
371

=
=
=
=
=
=
=
=
=
=
=
=
=

HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC
HVAC

Coil Data
Connector Data
Damper Data
Diffuser Data
Duct Data
DEquipment Data
Filter Data
Fitting Data
Grille Data
Hood Data
Humidifier Data
Register Data
Terminal Devices

EERWAY Category Object Types (300-306)


300
301
302
303
304
305
306
307
308

426

=
=
=
=
=
=
=
=
=

EERWAY
EERWAY
EERWAY
EERWAY
EERWAY
EERWAY
EERWAY
EERWAY
EERWAY

Connect Point
OneLine
Straight
Fitting
Space Envelope
To_Equipment
To_Support
Eqp Panel
Duct Bank

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL35, Approval Status (10)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
The following are the requirements in use of the "approval status."
2
reserved for approved
3
reserved for not approved
11-20
reserved for approved
21-30
reserved for not approved
1 = [Blank]
2 = A =Approved
3 = NA=Not approved

CL36, Structural Approval Status (15)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
0= New
1 = Existing
2 = Future
3 = User 1
4 = User 2

CL37, HVAC Approval Status (10)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1
2
3
4

=
=
=
=

New
Existing
Dismantle
Future

CL50, Hold Status (10)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only

Plant Design System (PDS) Reference Data Manager (PD_Data)

427

Appendix: Codelists
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed. Labels
always require that only values to the right of the "=" sign be displayed.
1 = NH=Not held
2 = H =Hold

CL69, Equipment Divisions/Form Code (99)


NOTE: In editing this codelist set, do not change the meaning
of codelist value "All". Some data displays require that only
values to the left of the "=" sign be shown; other data displays
require that only values to the right of the "=" sign be displayed.
1
2
3
4
5
6
7
8

=
=
=
=
=
=
=
=

A=
B=
C=
D=
E=
F=
H=
I=

All
Vessels
Heat transfer
Mechanical
Civil/Structural
Piping
Electrical
Other

CL125, Fluid Code/Connector Type (999)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values 950-999.
1 = [Blank]
11
14
17
20
23
26
29
32
35
40

428

=
=
=
=
=
=
=
=
=
=

A
AC
AE
AI
AO
AP
APU
AR
AS
AZ

[Air]
[Combustion air]
[Aeration air]
[Instrument air]
[Operational air]
[Plant air]
[Purge air]
[Regeneration air]
[Starting air]
[Other air]

71 = C
75 = CA
79 = CE
83 = CF
87 = CLP
91 = CPR
100 = CZ

[Refrigerant]
[Ammonia refrigerant]
[Ethylene refrigerant]
[Freon refrigerant]
[LP refrigerant]
[Propylene refrigerant]
[Other refrigerant]

101 = D

[Sewer]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
103
105
107
109
111
113
115
117
119
121
123
125
127
128
130

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

DC
DCH
DGR
DOW
DP
DPH
DS
DSP
DST
DW
DWS
DX
[Blank]
[Blank]
DZ

[Caustic sewer]
[Chemical sewer]
[Drain to grade]
[Oily water sewer]
[Process sewer]
[Heated process sewer]
[Sanitary sewer]
[Press sanitary sewer]
[Storm sewer]
[Clean water sewer]
[Sour water sewer]
[Acid sewer]
[Storm, oily water or sanitary sewer]
[Storm or oily water sewer]
[Other sewer]

161 = F

[Foam]

191
194
197
198
200
203
206
209
212
215
218
221
224
227
230
233
236
239
242
245
250

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

G
GCD
GCL
GCN
GF
GG
GH
GHS
GI
GLP
GM
GN
GNI
GOX
GP
GR
GS
GSO
GSW
GW
GZ

[Gas]
[Carbon dioxide gas]
[Chlorine gas]
[Chlorination gas]
[Fuel gas]
[Flue gas]
[Hydrogen gas]
[Hydrogen sulphide gas]
[Inert gas]
[LP gas]
[Make-up gas]
[Natural gas]
[Nitrogen gas]
[Oxygen gas]
[Purge gas]
[Reformed gas]
[Synthesis gas]
[Sour gas]
[Sweet gas]
[Waste gas
[Other gas]

341
346
351
356
370

=
=
=
=
=

K
KG
KF
KD
KZ

[Solvent]
[Glycol]
[Furfural]
[Dewaxing]
[Other solvent]

401
402
405
409
413
417
421
425

=
=
=
=
=
=
=
=

M
[Blank]
MAA
MAC
MAW
MC5
MCL
MEO

[Chemical]
[Chemical injection]
[Anhydrous ammonia]
[Aluminum chloride]
[Aqueous ammonia]
[0-50% caustic solution]
[Dry chlorine]
[Ethylene oxide]

Plant Design System (PDS) Reference Data Manager (PD_Data)

429

Appendix: Codelists

430

429
433
434
440
444
448
452
460

=
=
=
=
=
=
=
=

MHC
MIA
MIB
MLA
MMA
MS
MSL
MZ

[Hydrogen chloride]
[Inhibitor A]
[Inhibitor B]
[Lube oil additives]
[Methyl alcohol]
[Sulfur]
[Liquid sulfur]
[Other chemical]

491
493
495
497
499
500
503
505
507
509
511
513
515
520

=
=
=
=
=
=
=
=
=
=
=
=
=
=

O
OD
ODS
OF
OFR
OFS
OH
OL
OLS
OS
OSO
OSW
OWS
OZ

[Oil]
[Diesel fuel oil]
[Dry slop oil]
[Flushing oil]
[Fuel oil return]
[Fuel oil supply]
[Hydraulic oil]
[Lube]
[Lube and seal oil]
[Seal oil]
[Sour oil]
[Sweet oil]
[Wet slop oil]
[Other oil]

521
522
524
527
530
533
536
539
542
545
550

=
=
=
=
=
=
=
=
=
=
=

P
[Blank]
PA
PAS
PB
PH
PHH
PHW
PL
PS
PZ

[Process]
[Special process]
[Process w/ rich/lean amine]
[Process w/ severe amine]
[Process w/ benzene]
[Process w/ H2]
[Process w/ H2 & H2S]
[Process w/ aqueous H2S]
[Low temperature process]
[Process w/ S]
[Other process]

581 = RA
591 = RF
610 = RZ

[Relief to atmosphere]
[Relief to flare]
[Other relief]

611
613
615
617
621
623
625
627
629
631
633
635
640

[Steam]
[Boiler feed water or steam]
[Boiler feed water, steam or condensate]
[Steam or condensate]
[Extr press CL1500 steam]
[High press CL900 steam]
[Low press CL150 steam]
[Med press CL600 steam]
[Nor press CL300 steam]
[Superheated steam]
[Vacuum steam]
[Exhaust CL125 steam]
[Other steam]

=
=
=
=
=
=
=
=
=
=
=
=
=

S
[Blank]
[Blank]
[Blank]
SE
SH
SL
SM
SN
SS
SV
SX
SZ

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
641
643
645
647
649
651
653
655
660

=
=
=
=
=
=
=
=
=

SC
SCA
SCE
SCH
SCL
SCM
SCN
SCV
SCZ

[Steam condensate]
[Atmospheric CL125 steam condensate]
[Extr press CL1500 steam condensate]
[High press CL900 steam condensate]
[Low press CL150 steam condensate]
[Med press CL600 steam condensate]
[Nor press CL300 steam condensate]
[Vacuum steam condensate]
[Other steam condensate]

721
731
741
750

=
=
=
=

V
VA
VF
VZ

[Vent]
[Vent to atmosphere]
[Vent to flare]
[Other vent]

751
753
755
757
759
761
763
764
765
767
768
771
772
773
775
777
779
781
783
785
786
789
791
792
795
797
798
801
803
805
807
809
811
812
815
817
819
830

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

W
WB
WBA
WBB
WC
[Blank]
WCH
WCL
WCF
WCR
WCS
WPT
[Blank]
WDM
WFA
WFI
WFU
WG
WGL
WGR
WGS
WH
WHR
WHS
WI
WIR
WIS
WK
WN
WP
WR
WS
WSR
WSS
WT
WU
WW
WZ

[Water]
[Boiler feed water]
[Ballast water]
[Water boiler blowdown]
[Cooling water]
[Cooling or utility water]
[Chlorinated water]
[Chlorine in water]
[Clarified water]
[Cooling water return]
[Cooling water supply]
[Potable water]
[Potable water or instrument air]
[Demineralized water]
[Aboveground fire water]
[Filtered water]
[Underground fire water]
[Glycol water]
[Gland water]
[Glycol water return]
[Glycol water supply]
[Hot water]
[Hot water return]
[Hot water supply]
[Chilled water]
[Chilled water return]
[Chilled water supply]
[Treated water]
[Brine water]
[Process water]
[Raw water]
[Sea water]
[Sea water return]
[Sea water supply]
[Test water]
[Utility water]
[Waste water]
[Other water]

Plant Design System (PDS) Reference Data Manager (PD_Data)

431

Appendix: Codelists
831
835
839
843
847
851
853
860

=
=
=
=
=
=
=
=

X
XH
XN
XSD
XS3
XS8
XS9
XZ

[Acid]
[Hydrofluoric acid]
[Nitric acid]
[Dilute sulfuric acid]
[30% sulfuric acid]
[75-80% sulfuric acid]
[93-97% sulfuric acid]
[Other acid]

861
865
869
873
877
881
890

=
=
=
=
=
=
=

Y
YA
YG
YH
YL
YW
YZ

[Catalyst]
[Catalyst addition]
[General catalyst]
[Catalyst w/ H2]
[Catalyst lift lines]
[Catalyst withdrawal lines]
[Other catalyst]

950
951
953
955
956
960
961
999

=
=
=
=
=
=
=
=

ODPC
OUPC
UODPC
ODIC
OUIC
OVPC
OSPC
TERM

[Off-dwg piping connectors]


[Off-unit piping connectors]
[Utility off-dwg piping connectors]
[Off-dwg instr connectors]
[Off-unit instr connectors]
[Off-vol piping connectors]
[Off-site piping connectors]
[Terminator piping connector]

CL130, Construction Status (15)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values 2, 3 and 8. In addition, codelist
values 4-7 must imply an "existing" construction status. Codelist
values 9-15 inherit the color symbology from the construction
status of the item previously placed in the model.
1
2
3
4
5
6
7
8

=
=
=
=
=
=
=
=

[Blank]
New
Existing
Revamp
Relocate
Temporary
Dismantle
Future

CL145, Materials Grade (4500)


NOTE: Some data displays require that only values to the left of the
"=" sign be shown; other reports require that only values to the right
of the "=" sign be displayed.

432

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1 = [Blank]
Irons, 10-99
10 = A47-32510
12 = A47-35018
15 = A48-20
16 = A48-25
17 = A48-30
18 = A48-35
19 = A48-40
20 = A48-45
21 = A48-50
22 = A48-55
23 = A48-60
25 = A74
30 = A126-A
31 = A126-B
32 = A126-C
35 = A197
40 = A278-20
41 = A278-25
42 = A278-30
43 = A278-35
44 = A278-40
45 = A278-50
46 = A278-60
47 = A278-70
48 = A278-80
55 = A338
60 = A395-Ductile
62 = A395-Ferritic Ductile
70 = A571
75 = AWWA-C110-Ductile
76 = AWWA-C151-Ductile
Carbon Steels, 100-499
110 = API-5L-A
114 = API-5L-A25
116 = API-5L-B
118 = API-5L-X42
120 = API-5L-X46
122 = API-5L-X52
124 = API-5L-X65
135 = A36
140 = A53-A
142 = A53-B
144 = A53-Type F
150 = A105
160 = A106-A
162 = A106-B
164 = A106-C
170 = A120
180 = A134-A36
182 = A134-A283-A

Plant Design System (PDS) Reference Data Manager (PD_Data)

433

Appendix: Codelists
183
184
185
186
187
188
190
191
192
193
194
195
200
202
210
212
214
216
218
220
230
234
240
241
242
243
244
245
250
252
254
264
266
270
272
274
276
280
282
284
290
293
295
298
300
302
305
310
312
320
321
322
323
325

434

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A134-A283-B
A134-A283-C
A134-A283-D
A134-A285-A
A134-A285-B
A134-A285-C
A134-A570-30
A134-A570-33
A134-A570-36
A134-A570-40
A134-A570-45
A134-A570-50
A135-A
A135-B
A139-A
A139-B
A139-C
A139-D
A139-E
A179
A181-CL60
A181-CL70
A211-A570-30
A211-A570-33
A211-A570-36
A211-A570-40
A211-A570-45
A211-A570-50
A216-WCA
A216-WCB
A216-WCC
A234-WPB
A234-WPC
A283-A
A283-B
A283-C
A283-D
A285-A
A285-B
A285-C
A333-1
A333-6
A334-1
A334-6
A350-LF1
A350-LF2
A352-LCB
A369-FPA
A369-FPB
A381-Y35
A381-Y42
A381-Y46
A381-Y48
A381-Y50

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
327
334
340
342
344
346
350
352
354
356
360
361
362
363
364
365
370
372
375
380
390
392
394
396
398
400
402
404
406
408
410
420
422
424
426
428
430
432
434
436
438
440
442
444
446
448
460
464

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A381-Y52
A420-WPL6
A515-55
A515-60
A515-65
A515-70
A516-55
A516-60
A516-65
A516-70
A520-30
A520-33
A520-36
A520-40
A520-45
A520-50
A524-I
A524-II
A537-CL1
A587
A671-CA55
A671-CB60
A671-CB65
A671-CB70
A671-CC60
A671-CC65
A671-CC70
A671-CD70
A671-CE55
A671-CE60
A671-CK75
A672-A45
A672-A50
A672-A55
A672-B55
A672-B60
A672-B65
A672-B70
A672-C55
A672-C60
A672-C65
A672-C70
A672-D70
A672-E55
A672-E60
A672-N75
A691-CMS75
A691-CMSH70

Low
510
512
514
516

and Intermediate Alloy Steels, 500-899


= A182-F1
= A182-F2
= A182-F5
= A182-F5a

Plant Design System (PDS) Reference Data Manager (PD_Data)

435

Appendix: Codelists
518
519
520
521
523
524
526
528
530
532
534
536
540
542
550
552
554
556
560
562
564
576
578
580
582
584
586
588
590
600
602
610
614
616
618
620
622
624
630
632
634
636
644
646
648
650
652
664
666
668
670
680
682
684

436

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A182-F6a Cl.1
A182-F6a Cl.2
A182-F6a Cl.3
A182-F6a Cl.4
A182-F6b
A182-F7
A182-F9
A182-F11
A182-F12
A182-F21
A182-F22
A182-F22a
A202-A
A202-B
A203-A
A203-B
A203-D
A203-E
A204-A
A204-B
A204-C
A217-C5
A217-C12
A217-CA15
A217-WC1
A217-WC4
A217-WC5
A217-WC6
A217-WC9
A225-A
A225-B
A234-WP1
A234-WP5
A234-WP7
A234-WP9
A234-WP11
A234-WP12
A234-WP22
A302-A
A302-B
A302-C
A302-D
A333-3
A333-4
A333-7
A333-8
A333-9
A334-3
A334-7
A334-8
A334-9
A335-P1
A335-P2
A335-P5

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
686
687
690
692
694
696
698
700
702
710
720
722
724
730
740
742
744
746
748
750
752
754
756
758
760
761
770
771
774
775
778
779
780
781
782
783
784
785
786
787
794
798
800
802
804
806
808
810
812
814
816
817
820
822

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A335-P5b
A335-P5c
A335-P7
A335-P9
A335-P11
A335-P12
A335-P15
A335-P21
A335-P22
A350-LF3
A352-LC1
A352-LC2
A352-LC3
A353
A369-FP1
A369-FP2
A369-FP3b
A369-FP5
A369-FP7
A369-FP9
A369-FP11
A369-FP12
A369-FP21
A369-FP22
A385-7 Cl.1
A385-7 Cl.2
A387-2 Cl.1
A387-2 Cl.2
A387-5 Cl.1
A387-5 Cl.2
A387-9 Cl.1
A387-9 Cl.2
A387-11 Cl.1
A387-11 Cl.2
A387-12 Cl.1
A387-12 Cl.2
A387-21 Cl.1
A387-21 Cl.2
A387-22 Cl.1
A387-22 Cl.2
A420-WPL3
A420-WPL8
A426-CP1
A426-CP2
A426-CP5
A426-CP5b
A426-CP7
A426-CP9
A426-CP11
A426-CP12
A426-CP15
A426-CPCA15
A426-CP21
A426-CP22

Plant Design System (PDS) Reference Data Manager (PD_Data)

437

Appendix: Codelists
830
832
835
840
842
850
852
854
860
862
864
866
868
870
872
874
876
878

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A553-Type I
A553-Type II
A645
A671-CF70
A671-CF71
A672-L65
A672-L70
A672-L75
A691-CM65
A691-CM70
A691-CM75
A691-0.5Cr
A691-1Cr
A691-1.25Cr
A691-2.25Cr
A691-3Cr
A691-5Cr
A691-9Cr

Stainless Steels, 900-1324


920 = A167-301
922 = A167-302
923 = A167-302B
926 = A167-304
927 = A167-304L
930 = A167-305
932 = A167-308
934 = A167-309
935 = A167-309S
938 = A167-310
939 = A167-310S
942 = A167-316
943 = A167-316L
946 = A167-317
947 = A167-317L
950 = A167-321
952 = A167-347
954 = A167-348
960 = A182-F10
964 = A182-F304
965 = A182-F304H
966 = A182-F304L
968 = A182-F310
970 = A182-F316
971 = A182-F316H
972 = A182-F316L
974 = A182-F321
975 = A182-F321H
978 = A182-F347
979 = A182-F347H
982 = A182-F348
983 = A182-F348H
990 = A240-X8M
992 = A240-302

438

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
994 = A240-304
995 = A240-304L
996 = A240-304H
998 = A240-305
1000 = A240-309S
1004 = A240-310S
1006 = A240-316
1007 = A240-316L
1010 = A240-317
1011 = A240-317L
1014 = A240-321
1016 = A240-347
1018 = A240-348
1020 = A240-405
1022 = A240-410
1023 = A240-410S
1026 = A240-429
1028 = A240-430
1040 = A268-TP329
1044 = A268-TP405
1046 = A268-TP409
1048 = A268-TP410
1050 = A268-TP430
1051 = A268-TP430Ti
1054 = A268-TP443
1056 = A268-TP446
1060 = A269-TP304
1061 = A269-TP304L
1064 = A269-TP316
1065 = A269-TP316L
1066 = A270-TP316L
1070 = A312-TP304
1071 = A312-TP304H
1072 = A312-TP304L
1074 = A312-TP309
1076 = A312-TP310
1078 = A312-TP316
1079 = A312-TP316H
1080 = A312-TP316L
1082 = A312-TP317
1084 = A312-TP321
1085 = A312-TP321H
1088 = A312-TP347
1089 = A312-TP347H
1092 = A312-TP348
1095 = A351-CA15
1100 = A351-CF3
1102 = A351-CF3A
1104 = A351-CF3M
1106 = A351-CF8
1108 = A351-CF8A
1110 = A351-CF8C
1112 = A351-CF8M
1113 = A351-CF10

Plant Design System (PDS) Reference Data Manager (PD_Data)

439

Appendix: Codelists
1114
1116
1118
1120
1122
1124
1126
1128
1130
1140
1141
1144
1146
1148
1149
1152
1154
1156
1160
1162
1163
1166
1167
1170
1171
1174
1175
1178
1179
1190
1191
1192
1194
1196
1198
1199
1200
1202
1204
1205
1206
1207
1210
1220
1222
1224
1226
1228
1230
1232
1234
1240
1241
1244

440

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

A351-CF10MC
A351-CN7M
A351-CH8
A351-CH10
A351-CH20
A351-CK20
A351-HK30
A351-HK40
A351-HT30
A358-304
A358-304L
A358-309S
A358-310S
A358-316
A358-316L
A358-321
A358-347
A358-348
A376-16-8-2H
A376-TP304
A376-TP304H
A376-TP316
A376-TP316H
A376-TP321
A376-TP321H
A376-TP347
A376-TP347H
A376-TP348
A376-TP348H
A403-WP304
A403-WP304H
A403-WP304L
A403-WP309
A403-WP310
A403-WP316
A403-WP316H
A403-WP316L
A403-WP317
A403-WP321
A403-WP321H
A403-WP347
A403-WP347H
A403-WP348
A409-TP304
A409-TP309
A409-TP310
A409-TP316
A409-TP317
A409-TP321
A409-TP347
A409-TP348
A430-FP304
A430-FP304H
A430-FP316

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1245
1248
1249
1252
1253
1260
1262
1264
1266
1268
1270
1272
1280
1282
1284
1300

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Copper
1325 =
1330 =
1331 =
1334 =
1335 =
1338 =
1339 =
1342 =
1346 =
1350 =
1354 =
1356 =
1358 =
1362 =
1363 =
1364 =
1368 =
1369 =
1370 =
1374 =
1375 =
1376 =
1380 =
1381 =
1382 =
1386 =
1387 =
1392 =
1393 =
1398 =
1399 =
1404 =
1408 =
1410 =
1412 =
1414 =

A430-FP316H
A430-FP321
A430-FP321H
A430-FP347
A430-FP347H
A451-CHP10
A451-CHP20
A451-CPF8C
A451-CPF8M
A451-CPF10MC
A451-CPH8
A451-CPK20
A452-TP304H
A452-TP316H
A452-TP347H
ASME SA479-316L
and Copper Alloys, 1325-1549
AISI-CDA Alloy 377
B42 Cl.C10200, drwn, NPD 0.0625-2
B42 Cl.C10200, drwn, NPD 2.5-12
B42 Cl.C12000, drwn, NPD 0.0625-2
B42 Cl.C12000, drwn, NPD 2.5-12
B42 Cl.C12200, drwn, NPD 0.0625-2
B42 Cl.C12200, drwn, NPD 2.5-12
B43 Cl.C23000, annld
B61 Cl.C92200
B62 Cl.C83600
B68 Cl.C10200, annld
B68 Cl.C12000, annld
B68 Cl.C12200, annld
B75 Cl.C10200, annld
B75 Cl.C10200, hrd drwn
B75 Cl.C10200, light drwn
B75 Cl.C12000, annld
B75 Cl.C12000, hrd drwn
B75 Cl.C12000, light drwn
B75 Cl.C12200, annld
B75 Cl.C12200, hrd drwn
B75 Cl.C12200, light drwn
B75 Cl.C14200, annld
B75 Cl.C14200, hrd drwn
B75 Cl.C14200, light drwn
B88 Cl.C10200, annld
B88 Cl.C10200, drwn
B88 Cl.C12000, annld
B88 Cl.C12000, drwn
B88 Cl.C12200, annld
B88 Cl.C12200, drwn
B96 Cl.C65500, annld
B152 Cl.C10200, annld
B152 Cl.C10400, annld
B152 Cl.C10500, annld
B152 Cl.C10700, annld

Plant Design System (PDS) Reference Data Manager (PD_Data)

441

Appendix: Codelists
1416
1418
1422
1430
1432
1434
1436
1438
1440
1442
1450
1452
1456
1458
1462
1463
1466
1467
1472
1474
1476
1478
1480
1482
1484
1486
1488
1490
1492
1494
1496
1498
1500
1502

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Nickel
1560 =
1561 =
1564 =
1565 =
1568 =
1572 =
1573 =
1574 =
1576 =
1577 =
1578 =
1582 =
1586 =
1587 =
1590 =
1591 =
1594 =
1595 =

442

B152
B152
B169
B283
B283
B283
B283
B283
B283
B283
B402
B402
B466
B466
B467
B467
B467
B467
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584
B584

Cl.C12200,
Cl.C12300,
Cl.C61400,
Cl.C11000
Cl.C37700
Cl.C46400
Cl.C48500
Cl.C63900
Cl.C65500
Cl.C67500
Cl.C70600,
Cl.C71500,
Cl.C70600,
Cl.C71500,
Cl.C70600,
Cl.C70600,
Cl.C71500,
Cl.C71500,
Cl.C86200
Cl.C86300
Cl.C86400
Cl.C86500
Cl.C86700
Cl.C90300
Cl.C90500
Cl.C92200
Cl.C92300
Cl.C95200
Cl.C95300
Cl.C95500
Cl.C95600
Cl.C97300
Cl.C97600
Cl.C97800

annld
annld
soft

annld
annld
annld
annld
annld,
annld,
annld,
annld,

<=4.5in OD
>4.5in OD
<=4.5in OD
>4.5in OD

and Nickel Alloys 1550-1774


B127-400 (N04400) hot rolled plt annld
B127-400 (N04400) hot rolled plt AR
B160-200 (N02200) annld
B160-200 (N02200) hot fin
B160-201 annld
B161-200 (N02200) annld, <=5in OD
B161-200 (N02200) annld, >5in OD
B161-200 (N02200) stress rlvd
B161-201 (N02201) annld, <=5in OD
B161-201 (N02201) annld, >5in OD
B161-201 (N02201) stress rlvd
B162-200 (N02200) hot rolled plt annld
B162-201 (N02201) hot rolled plt annld
B162-201 (N02201) hot rolled plt AR
B164-400 (N04400) annld forged
B164-400 (N04400) hot fin
B165-400 (N04400) annld, <=5in OD
B165-400 (N04400) annld, >5in OD

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1596
1600
1601
1604
1605
1606
1607
1610
1611
1614
1615
1616
1620
1624
1626
1628
1630
1632
1634
1636
1638
1642
1643
1646
1648
1650
1652
1654
1656
1658
1660
1664
1666
1670
1672
1676
1680
1684
1688
1700
1702
1704
1706
1708
1710
1714
1718
1722
1724
1726
1728
1730
1732

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

B165-400 (N04400) stress rlvd


B166-600 (N06600) annld
B166-600 (N06600) hot fin
B167-600 (N06600) cold drwn annld, <=5in OD
B167-600 (N06600) cold drwn annld, >5in OD
B167-600 (N06600) hot fin/hot fin annld, <=5in OD
B167-600 (N06600) hot fin/hot fin annld, >5in OD
B168-600 (N06600) hot rolled plt annld
B168-600 (N06600) hot rolled plt AR
B333-B (N10001) sln annld plt
B333-B (N10001) sln annld sheet
B333-B-2 (N10665) sln annld
B335-B-2 (N10665) sln annld
B366-WPHB (N10001)
B366-WPHX (N06002)
B366-WPN (N02200)
B366-WPNC (N04400)
B366-WPNC1 (N06600)
B366-WPNL (N02201)
B366-WPNLWX
B366-WPNWX
B407-800 (N08800) cold drwn annld
B407-800 (N08800) hot fin/hot fin annld
B407-800H (N08810) cold drwn sln annld/hot fin
B443-625 (N06625) annld
B444-625 (N06625) annld
B446-625 (N06625) annld
B464-20Cb (N08020) annld
A494-CW-12M-1
A494-CW-12M-2
A494-CY-40
B574-C-4 (N06455) sln annld
B574-C-276 (N10276) sln annld
B575-C-4 (N06455) sln annld
B575-C-276 (N10276) sln annld
B581-G (N06007) sln annld
B582-G (N06007) sln annld
B612-200 (N02200) hot rolled plt AR
B619-20-Mod (N08320) sln annld
B619-B (N10001) sln annld
B619-B-2 (N10665) sln annld
B619-C-4 (N06455) sln annld
B619-C-276 (N10276) sln annld
B619-G1 (N06007) sln annld
B619-X (N06002) sln annld
B620-20-Mod (N08320) sln annld
B621-20-Mod (N08320) sln annld
B622-B (N10001) sln annld
B622-B-2 (N10655) sln annld
B622-C-4 (N06455) sln annld
B622-C-276 (N10276) sln annld
B622-G (N06007) sln annld
B622-X (N06002) sln annld

Plant Design System (PDS) Reference Data Manager (PD_Data)

443

Appendix: Codelists
Aluminum Alloys 1775-2299
1780 = B26-356.0 temper T6
1782 = B26-356.0 temper T71
1784 = B26-443.0 temper F
1790 = B209-1060 temper 0
1792 = B209-1060 temper H12
1794 = B209-1060 temper H14
1796 = B209-1060 temper H112
1798 = B209-1100 temper 0
1800 = B209-1100 temper H12
1802 = B209-1100 temper H14
1804 = B209-1100 temper H112
1806 = B209-3003 temper 0
1808 = B209-3003 temper H12
1810 = B209-3003 temper H14
1812 = B209-3003 temper H112
1814 = B209-3004 temper 0
1816 = B209-3004 temper H32
1818 = B209-3004 temper H34
1820 = B209-3004 temper H112
1822 = B209-5050 temper 0
1824 = B209-5050 temper H32
1826 = B209-5050 temper H34
1828 = B209-5050 temper H112
1830 = B209-5052 temper 0
1832 = B209-5052 temper H32
1834 = B209-5052 temper H34
1836 = B209-5052 temper H112
1838 = B209-5652 temper 0
1840 = B209-5652 temper H32
1842 = B209-5652 temper H34
1844 = B209-5652 temper H112
1846 = B209-5083 temper 0
1848 = B209-5083 temper H321
1850 = B209-5086 temper 0
1852 = B209-5086 temper H32
1854 = B209-5086 temper H34
1856 = B209-5086 temper H112
1858 = B209-5154 temper 0
1860 = B209-5154 temper H32
1862 = B209-5154 temper H34
1864 = B209-5154 temper H112
1866 = B209-5254 temper 0
1868 = B209-5254 temper H32
1870 = B209-5254 temper H34
1872 = B209-5254 temper H112
1874 = B209-5454 temper 0
1876 = B209-5454 temper H32
1878 = B209-5454 temper H34
1880 = B209-5454 temper H112
1882 = B209-5456 temper 0
1884 = B209-5456 temper H321
1886 = B209-6061 temper T4
1888 = B209-6061 temper T4, wld

444

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1890
1892
1894
1896
1898
1900
1902
1904
1906
1908
1910
1912
1914
1916
1918
1920
1922

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

B209-6061 temper
B209-6061 temper
B209-6061 temper
B209-Alclad 3003
B209-Alclad 3003
B209-Alclad 3003
B209-Alclad 3003
B209-Alclad 3004
B209-Alclad 3004
B209-Alclad 3004
B209-Alclad 3004
B209-Alclad 6061
B209-Alclad 6061
B209-Alclad 6061
B209-Alclad 6061
B209-Alclad 6061
B209-Alclad 6061

T6
T6, wld
T651
temper 0
temper H12
temper H14
temper H112
temper 0
temper H32
temper H34
temper H112
temper T4
temper T4, wld
temper T6
temper T6, wld
temper T451
temper T651

1930
1932
1934
1936
1938
1940
1942
1944
1946
1948
1950
1952
1954
1956
1958
1960
1962
1964
1966
1968
1970
1972
1974
1976
1978
1980
1982
1984
1986
1988
1990
1992
1994
2010
2012
2014

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

B210-1060 temper
B210-1060 temper
B210-1060 temper
B210-3003 temper
B210-3003 temper
B210-3003 temper
B210-3003 temper
B210-5052 temper
B210-5052 temper
B210-5052 temper
B210-5083 temper
B210-5083 temper
B210-5086 temper
B210-5086 temper
B210-5086 temper
B210-5086 temper
B210-5154 temper
B210-5154 temper
B210-5456 temper
B210-5456 temper
B210-6061 temper
B210-6061 temper
B210-6061 temper
B210-6061 temper
B210-6063 temper
B210-6063 temper
B210-6063 temper
B210-6063 temper
B210-6063 temper
B210-Alclad 3002
B210-Alclad 3003
B210-Alclad 3003
B210-Alclad 3002
B221-1060 temper
B221-1060 temper
B221-1100 temper

0
H14
H112
0
H14
H18
H112
0
H32
H34
0
H112
0
H32
H34
H112
0
H34
0
H112
T4
T4, wld
T6
T6, wld
T4
T4, wld
T5, wld
T6
T6, wld
temper 0
temper H14
temper H18
temper H112
0
H112
0

Plant Design System (PDS) Reference Data Manager (PD_Data)

445

Appendix: Codelists
2016
2018
2020
2022
2024
2026
2028
2030
2032
2034
2036
2038
2040
2042
2044
2046
2048
2050
2052
2054
2056
2070
2072
2074
2076
2078
2080
2082
2084
2086
2088
2090
2092
2094
2096
2098
2100
2102
2104
2106
2108
2110
2112
2114
2116
2118
2120
2122
2124
2126
2128
2130
2140
2142

446

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

B221-1100 temper
B221-3003 temper
B221-3003 temper
B221-5052 temper
B221-5053 temper
B221-5086 temper
B221-5154 temper
B221-5454 temper
B221-5456 temper
B221-6061 temper
B221-6061 temper
B221-6061 temper
B221-6061 temper
B221-6063 temper
B221-6063 temper
B221-6063 temper
B221-6063 temper
B221-6063 temper
B221-6063 temper
B221-Alclad 3003
B221-Alclad 3003
B241-1060 temper
B241-1060 temper
B241-1100 temper
B241-1100 temper
B241-3003 temper
B241-3003 temper
B241-3003 temper
B241-5052 temper
B241-5083 temper
B241-5083 temper
B241-5086 temper
B241-5086 temper
B241-5454 temper
B241-5454 temper
B241-5456 temper
B241-5456 temper
B241-5462 temper
B241-5462 temper
B241-6061 temper
B241-6061 temper
B241-6061 temper
B241-6061 temper
B241-6061 temper
B241-6063 temper
B241-6063 temper
B241-6063 temper
B241-6063 temper
B241-6063 temper
B241-6063 temper
B241-Alclad 3003
B241-Alclad 3003
B247-3003 temper
B247-3003 temper

H112
0
H112
0
0
0
0
0
0
T4
T4, wld
T6
T6, wld
T4
T4, wld
T5
T5, wld
T6
T6, wld
temper 0
temper H112
0
H112
0
H112
0
H18
H112
0
0
H112
0
H112
0
H112
0
H112
0
H112
T4
T4, wld
T6, <NPD 1
T6, =>NPD 1
T6, wld
T4
T4, wld
T5
T5, wld
T6
T6, wld
temper 0
temper H112
H112
H112, wld

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
2144
2146
2148
2150
2152
2160
2162
2164
2166
2168
2170
2172
2174
2176
2178
2180
2182
2184
2186
2188
2190
2192
2194
2196
2198
2200
2202
2220
2222
2224
2226
2228
2230
2232
2234
2236
2238
2240
2242
2244
2246
2248
2250
2252
2254

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

B247-5083 temper 0
B247-5083 temper H112
B247-5083 temper H112, wld
B247-6061 temper T6
B247-6061 temper T6, wld
B345-1060 temper 0
B345-1060 temper H112
B345-3003 temper 0
B345-3003 temper H18
B345-3003 temper H112
B345-5083 temper 0
B345-5083 temper H112
B345-5086 temper 0
B345-5086 temper H112
B345-6061 temper T4
B345-6061 temper T4, wld
B345-6061 temper T6, <NPD 1
B345-6061 temper T6, =>NPD 1
B345-6061 temper T6, wld
B345-6063 temper T4
B345-6063 temper T4, wld
B345-6063 temper T5
B345-6063 temper T5, wld
B345-6063 temper T6
B345-6063 temper T6, wld
B345-Alclad 3002 temper 0
B345-Alclad 3002 temper H112
B361-WP1060 temper 0
B361-WP1060 temper H112
B361-WP1100 temper 0
B361-WP1100 temper H112
B361-WP3003 temper 0
B361-WP3003 temper H112
B361-WP5154 temper 0
B361-WP5154 temper H112
B361-WP6061 temper T4
B361-WP6061 temper T4, wld
B361-WP6061 temper T6
B361-WP6061 temper T6, wld
B361-WP6063 temper T4
B361-WP6063 temper T4, wld
B361-WP6063 temper T6
B361-WP6063 temper T6, wld
B361-AP Alclad 3003 temper 0
B361-AP Alclad 3003 temper H112

Other Materials 2300-2999


2310 = B337-1
2311 = B337-2
2313 = B337-3
2317 = B337-7
2320 = C76-CLIII
2325 = C443
2350 = C700

Plant Design System (PDS) Reference Data Manager (PD_Data)

447

Appendix: Codelists
2400
2402
2440
2442

=
=
=
=

D1785-PVC1120
D2467-PVC1120
F439-CPVC4120
F441-CPVC4120

Gaskets 3000-3999]
3051 = G51
[Flat,
3052 = G52
[Flat,
3076 = G76
[Flat,
3077 = G77
[Flat,
3078 = G78
[Flat,
3079 = G79
[Flat,
3101 = G101
[Flat,
3102 = G102
[Flat,
3103 = G103
[Flat,
3111 = G111
[Flat,
3112 = G112
[Flat,
3154 = G154
[Flat,
3171 = G171
[Flat,
3175 = G175
[Flat,
3189 = G189
[Flat,
3195 = G195
[Flat,
3204 = G204
[Flat,
3210 = G210
[Flat,
3231 = G231
[Flat,
3234 = G234
[Flat,
3236 = G236
[Flat,
3241 = G241
[Corr,
3244 = G244
[Corr,
3246 = G246
[Corr,

448

org fib, nitrile binder]


org fib, nitrile binder, full face]
graph]
graph, full face]
graph, 304 tang reinf]
graph, 304 wire mesh reinf]
asb]
asb, full face]
asb, wire mesh reinf]
blue-asb]
blue-asb, full face]
Buna-N]
Hypalon]
Kel-F]
neoprene]
polyethylene]
Teflon]
Viton]
soft-iron]
304]
321/347
soft-iron]
304]
321/347

3251
3256
3261
3262
3266
3267
3271
3272
3276
3277
3281
3282
3286

=
=
=
=
=
=
=
=
=
=
=
=
=

G251
G256
G261
G262
G266
G267
G271
G272
G276
G277
G281
G282
G286

[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat
[Flat

dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl

jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,

PTFE-J, asb-F]
Teflon-J, blue-asb-F]
soft-iron-J, graph-F]
soft-iron-J, asb-F]
low-C-steel-J, graph-F]
low-C-steel-J, asb-F]
304-J, graph-F]
304-J, asb-F]
321/347-J, graph-F]
321/347-J, asb-F]
I600-J, graph-F]
I600-J, asb-F]
I800-J, graph-F

3306
3307
3311
3312
3316
3317
3321
3322
3326

=
=
=
=
=
=
=
=
=

G306
G307
G311
G312
G316
G317
G321
G322
G326

[Corr
[Corr
[Corr
[Corr
[Corr
[Corr
[Corr
[Corr
[Corr

dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl
dbl

jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,
jktd,

soft-iron-J, graph-F]
soft-iron-J, asb-F]
low-C-steel-J, graph-F]
low-C-steel-J, asb-F]
304-J, graph-F]
304-J, asb-F]
321/347-J, graph-F]
321/347-J, asb-F]
I600-J, graph-F]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
3327 = G327
3331 = G331

[Corr dbl jktd, I600-J, asb-F]


[Corr dbl jktd, I800-J, graph-F

3356 = G356
3361 = G361
3366 = G366

[Inlaid corr, soft-iron-J, asb-chords]


[Inlaid corr, low-C-steel-J, asb-chords]
[Inlaid corr, 304-J, asb-chords

3403
3404
3408
3429
3435
3436
3441

=
=
=
=
=
=
=

G403
G404
G408
G429
G435
G436
G441

[O
[O
[O
[O
[O
[O
[O

3451
3452
3463
3466
3468
3473

=
=
=
=
=
=

G451
G452
G463
G466
G468
G473

[BX
[BX
[BX
[BX
[BX
[BX

ring,
ring,
ring,
ring,
ring,
ring,

soft-iron, 90 BHN max]


lo-C, 120 BHN max]
304, 140 BHN max]
316, 140 BHN max]
321, 140 BHN max]
I-X-750

3476
3477
3488
3491
3493
3498

=
=
=
=
=
=

G476
G477
G488
G491
G493
G498

[RX
[RX
[RX
[RX
[RX
[RX

ring,
ring,
ring,
ring,
ring,
ring,

soft-iron, 90 BHN max]


lo-C, 120 BHN max]
304, 140 BHN max]
316, 140 BHN max]
321, 140 BHN max]
I-X-750

3551
3552
3556
3563
3566
3568
3569
3573

=
=
=
=
=
=
=
=

G551
G552
G556
G563
G566
G568
G569
G573

[Octag
[Octag
[Octag
[Octag
[Octag
[Octag
[Octag
[Octag

3601
3602
3606
3608
3610
3613
3616
3618
3619
3623

=
=
=
=
=
=
=
=
=
=

G601
G602
G606
G608
G610
G613
G616
G618
G619
G623

[Oval
[Oval
[Oval
[Oval
[Oval
[Oval
[Oval
[Oval
[Oval
[Oval

3651
3653
3655
3657
3659

=
=
=
=
=

G651
G653
G655
G657
G659

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

ring,
ring,
ring,
ring,
ring,
ring,
ring,

Buna-N]
butyl]
EDPM]
nitrile]
Saran]
synthetic rubber]
Viton

ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,
ring,

soft-iron, 90 BHN max]


lo-C, 120 BHN max]
5Cr-0.5Mo, 130 BHN max]
304, 140 BHN max]
316, 140 BHN max]
321, 140 BHN max]
347, 140 BHN max]
I-X-750
soft-iron, 90 BHN max]
lo-C, 120 BHN max]
5Cr-0.5Mo, 130 BHN max]
9Cr-1Mo, 130 BHN max]
410, 170 BHN max]
304, 140 BHN max]
316, 140 BHN max]
321, 140 BHN max]
347, 140 BHN max]
I-X-750

304-W,
304-W,
304-W,
304-W,
304-W,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
blue-asb-F, CS-CR]
Teflon-F, CS-CR]

Plant Design System (PDS) Reference Data Manager (PD_Data)

449

Appendix: Codelists

450

3661
3663
3665
3669

=
=
=
=

G661
G663
G665
G669

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

304-W,
304-W,
304-W,
304-W,

mica/graph-F, CS-CR, 304-IR]


graph-F, CS-CR, 304-IR]
asb-F, CS-CR, 304-IR]
Teflon-F, CS-CR, 304-IR

3671
3673
3675
3677
3679
3681
3683
3685
3689

=
=
=
=
=
=
=
=
=

G671
G673
G675
G677
G679
G681
G683
G685
G689

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

316-W,
316-W,
316-W,
316-W,
316-W,
316-W,
316-W,
316-W,
316-W,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
crodidolite asb-F, CS-CR]
Teflon-F, CS-CR]
mica/graph-F, CS-CR, 316-IR]
graph-F, CS-CR, 316-IR]
asb-F, CS-CR, 316-IR]
Teflon-F, CS-CR, 316-IR

3691
3693
3695
3699
3701
3703
3705
3709

=
=
=
=
=
=
=
=

G691
G693
G695
G699
G701
G703
G705
G709

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

316L-W,
316L-W,
316L-W,
316L-W,
316L-W,
316L-W,
316L-W,
316L-W,

3711
3713
3715
3719
3721
3723
3725
3729

=
=
=
=
=
=
=
=

G711
G713
G715
G719
G721
G723
G725
G729

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

321-W,
321-W,
321-W,
321-W,
321-W,
321-W,
321-W,
321-W,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
Teflon-F, CS-CR]
mica/graph-F, CS-CR, 321-IR]
graph-F, CS-CR, 321-IR]
asb-F, CS-CR, 321-IR]
Teflon-F, CS-CR, 321-IR

3731
3733
3735
3739
3741
3743
3745
3749

=
=
=
=
=
=
=
=

G731
G733
G735
G739
G741
G743
G745
G749

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

347-W,
347-W,
347-W,
347-W,
347-W,
347-W,
347-W,
347-W,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
Teflon-F, CS-CR]
mica/graph-F, CS-CR, 347-IR]
graph-F, CS-CR, 347-IR]
asb-F, CS-CR, 347-IR]
Teflon-F, CS-CR, 347-IR

3751
3753
3755
3761
3763
3765
3771
3773
3775
3781
3783
3785

=
=
=
=
=
=
=
=
=
=
=
=

G751
G753
G755
G761
G763
G765
G771
G773
G775
G781
G783
G785

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
Teflon-F, CS-CR]
mica/gra-F, CS-CR, 316L-IR]
graph-F, CS-CR, 316L-IR]
asb-F, CS-CR, 316L-IR]
Teflon-F, CS-CR, 316L-IR

I600-W,
I600-W,
I600-W,
I600-W,
I600-W,
I600-W,
I800-W,
I800-W,
I800-W,
I800-W,
I800-W,
I800-W,

mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
mica/graph-F, I600-O&IR]
graph-F, I600-O&IR]
asb-F, I600-O&IR
mica/graph-F, CS-CR]
graph-F, CS-CR]
asb-F, CS-CR]
mica/graph-F, I800-O&IR]
graph-F, I800-O&IR]
asb-F, I800-O&IR

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
Bolting 4000-4999]
4011 = B11
4012 = B12
4014 = B14
4015 = B15
4021 = B21
4022 = B22
4031 = B31
4032 = B32
4033 = B33
4035 = B35
4038 = B38
4039 = B39
4041 = B41
4042 = B42
4044 = B44
4045 = B45
4046 = B46
4047 = B47
4048 = B48
4050 = B50
4051 = B51
4061 = B61
4062 = B62
4064 = B64
4065 = B65
4066 = B66
4067 = B67
4068 = B68
4069 = B69
4071 = B71
4074 = B74
4075 = B75
4076 = B76
4077 = B77
4078 = B78
4079 = B79
4080 = B80
4081 = B81
4082 = B82
4084 = B84
4085 = B85

[A193-B5, >=1.5" lub, w/A194-3]


[A193-B5, lub, w/A194-3]
[A193-B5, >=1.5" lub, w/A194-4]
[A193-B5, lub, w/A194-4]
[A193-B6, >=1.5" lub, w/A194-6]
[A193-B6, lub, w/A194-6]
[A193-B7, >=1.5" lub, w/A194-2H]
[A193-B7, lub, w/A194-2H]
[A193-B7 zinc coated w/A194-2H zinc coated]
[A193-B7 galv w/A194-2H galv]
[A193-B7M, >=1.5" lub, w/A194-2H]
[A193-B7M, lub, w/A194-2H]
[A193-B8 Cl.1, >=1.5" lub, w/A194-8]
[A193-B8 Cl.1, lub, w/A194-8]
[A193-B8C Cl.1, >=1.5" lub, w/A194-8C]
[A193-B8C Cl.1, lub, w/A194-8C]
[A193-B8 Cl.1, lub, w/A194-8]
[A193-B8M Cl.1, >=1.5" lub, w/A194-8M]
[A193-B8M Cl.1, lub, w/A194-8M
[A193-B8T Cl.1, >=1.5" lub, w/A194-8T]
[A193-B8T Cl.1, lub, w/A194-8T]
[A193-B16, >=1.5" lub, w/A194-3]
[A193-B16, lub, w/A194-3]
[A193-B16, >=1.5" lub, w/A194-4]
[A193-B16, lub, w/A194-4]
[A193-B16, >=1.5" lub, w/A194-7]
[A193-B16, lub, w/A194-7]
[A193-B16, >=1.5" lub, w/A194-8M]
[A193-B16, lub, w/A194-8M]
[A307-B w/A563-A]
[A320-L7, >=1.5" lub, w/A194-4]
[A320-L7, lub, w/A194-4]
[A320-B8, >=1.5" lub, w/A194-8]
[A320-B8, lub, w/A194-8]
[A320-B8, >=1.5" lub, w/A194-B8]
[A320-B8, lub, w/A194-B8]
[A320-B8T Cl.1 >=1.5" lub, w/A194-B8]
[A320-B8T Cl.1 lub, w/A194-B8]
[A325 w/A325]
[A453-660, >=1.5" lub, w/A453-660]
[A453-660, lub, w/A453-660

4500 = Undefined
Materials for British Standards - Ranges used 6000-7999
carbon
6000 =
6001 =
6002 =
6003 =
6004 =

steel pipes and tubes BS3601


BS3601:BW320
BS3601:ERW320
BS3601:ERW360
BS3601:ERW430
BS3601:S360

Plant Design System (PDS) Reference Data Manager (PD_Data)

451

Appendix: Codelists
6005 = BS3601:S430
6006 = BS3601:SAW430
steel pipes and tubes BS3602 part 1 1987
6010 = BS3602:PART 1:HFS360:Cat 1
6011 = BS3602:PART 1:HFS360:Cat 2
6012 = BS3602:PART 1:HFS430:Cat 1
6013 = BS3602:PART 1:HFS430:Cat 2
6014 = BS3602:PART 1:HFS500Nb:Cat 1
6015 = BS3602:PART 1:HFS500Nb:Cat 2
6016 = BS3602:PART 1:CFS360:Cat 1
6017 = BS3602:PART 1:CFS360:Cat 2
6018 = BS3602:PART 1:CFS430:Cat 1
6019 = BS3602:PART 1:CFS430:Cat 2
6020 = BS3602:PART 1:CFS500Nb:Cat 1
6021 = BS3602:PART 1:CFS500Nb:Cat 2
6022 = BS3602:PART 1:ERW360:Cat 1
6023 = BS3602:PART 1:ERW360:Cat 2
6024 = BS3602:PART 1:ERW430:Cat 1
6025 = BS3602:PART 1:ERW430:Cat 2
6026 = BS3602:PART 1:CEW360:Cat 1
6027 = BS3602:PART 1:CEW360:Cat 2
6028 = BS3602:PART 1:CEW430:Cat 1
6029 = BS3602:PART 1:CEW430:Cat 2
steel pipes and tubes elevated temp prop BS3602 part 2
6030 = BS3602:PART 2:SAW410:cat 1
6031 = BS3602:PART 2:SAW410:cat 2
6032 = BS3602:PART 2:SAW460:cat 1
6033 = BS3602:PART 2:SAW460:cat 2
steel pipes and tubes
6040 = BS3603 HFS410
6041 = BS3603 HFS410
6042 = BS3603 CFS410
6043 = BS3603 CFS410
6044 = BS3603 ERW410
6045 = BS3603 ERW410
6046 = BS3603 CEW410
6047 = BS3603 CEW410
6048 = BS3603 HFS503
6049 = BS3603 HFS503
6050 = BS3603 CFS503
6051 = BS3603 CFS503
6052 = BS3603 HFS509
6053 = BS3603 HFS509
6054 = BS3603 CFS509
6055 = BS3603 CFS509

low temp prop BS3603 1977


LT 50 Cat 1
LT 50 Cat 2
LT 50 Cat 1
LT 50 Cat 2
LT 50 Cat 1
LT 50 Cat 2
LT 50 Cat 1
LT 50 Cat 2
LT 100 Cat 1
LT 100 Cat 2
LT 100 Cat 1
LT 100 Cat 2
LT 196 Cat 1
LT 196 Cat 2
LT 196 Cat 1
LT 196 Cat 2

steel pipes and tubes elevated temp prop BS3604


6060 = BS3604:HFS620-460 Cat 1
6061 = BS3604:CFS620-460 Cat 1
6062 = BS3604:ERW620-460 Cat 1
6063 = BS3604:CEW620-460 Cat 1

452

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS3604:HFS620-460
BS3604:CFS620-460
BS3604:ERW620-460
BS3604:CEW620-460
BS3604:HFS620-440
BS3604:CFS620-440
BS3604:ERW620-440
BS3604:CEW620-440
BS3604:HFS620-440
BS3604:CFS620-440
BS3604:ERW620-440
BS3604:CEW620-440
BS3604:HFS621 Cat
BS3604:CFS621 Cat
BS3604:ERW621 Cat
BS3604:CEW621 Cat
BS3604:HFS621 Cat
BS3604:CFS621 Cat
BS3604:ERW621 Cat
BS3604:CEW621 Cat
BS3604:HFS660 Cat
BS3604:CFS660 Cat
BS3604:HFS660 Cat
BS3604:CFS660 Cat
BS3604:HFS622 Cat
BS3604:CFS622 Cat
BS3604:HFS622 Cat
BS3604:CFS622 Cat
BS3604:HFS625 Cat
BS3604:CFS625 Cat
BS3604:HFS625 Cat
BS3604:CFS625 Cat
BS3604:HFS629-470
BS3604:CFS629-470
BS3604:HFS629-470
BS3604:CFS629-470
BS3604:HFS629-590
BS3604:CFS629-590
BS3604:HFS629-590
BS3604:CFS629-590
BS3604:HFS762 Cat
BS3604:CFS762 Cat
BS3604:HFS762 Cat
BS3604:CFS762 Cat

Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
1
1
1
1
2
2
2
2
1
1
2
2
1
1
2
2
1
1
2
2
Cat
Cat
Cat
Cat
Cat
Cat
Cat
Cat
1
1
2
2

2
2
2
2
1
1
1
1
2
2
2
2

1
1
2
2
1
1
2
2

SS pipes and tubes for pressure purposes BS3605:1973


6110 = BS3605 304S14
6111 = BS3605 304S18
6112 = BS3605 304S59
6113 = BS3605 304S22
6114 = BS3605 304S25
6115 = BS3605 316S14
6116 = BS3605 316S18
6117 = BS3605 316S59

Plant Design System (PDS) Reference Data Manager (PD_Data)

453

Appendix: Codelists
6118
6119
6120
6121
6122
6123
6124
6125
6126

=
=
=
=
=
=
=
=
=

plates
6200 =
6201 =
6202 =
6203 =
6204 =
6205 =
6206 =
6207 =
6208 =
6209 =
6210 =
6211 =
6212 =
6213 =
6214 =
6215 =
6216 =
6217 =
6218 =
6219 =
6220 =
6221 =
6222 =
6223 =
6224 =
6225 =
6226 =
6227 =
6228 =
6229 =
6230 =
6231 =
6232 =
6233 =
6234 =
6235 =
6236 =
6237 =
6238 =
6239 =
6240 =
6241 =
6242 =

454

BS3605
BS3605
BS3605
BS3605
BS3605
BS3605
BS3605
BS3605
BS3605

316S22
316S26
321S18
321S59(1010)
321S59(1105)
321S22
347S18
347S59
347S17

BS1501 part
BS1501-141
BS1501-151
BS1501-151
BS1501-151
BS1501-151
BS1501-151
BS1501-151
BS1501-154
BS1501-154
BS1501-154
BS1501-161
BS1501-161
BS1501-161
BS1501-161
BS1501-161
BS1501-161
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-164
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223
BS1501-223

1 1980
360A
360A
400A
430A
360B
400B
430B
360A
400A
430A
360A
400A
430A
360B
400B
430B
360A RT
360A LT0
360A LT20
360B RT
360B LT0
360B LT20
400A RT
400A LT0
400A LT20
400B RT
400B LT0
400B LT20
460A RT
460A LT0
460A LT15
460A LT30
460B RT
460B LT0
460B LT15
460B LT30
490A RT
490A LT0
490A LT15
490A LT30
490B RT
490B LT0
490B LT15

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1501-223
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-224
BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225

490B
400A
400A
400A
400A
400A
400A
400B
400B
400B
400B
400B
400B
430A
430A
430A
430A
430A
430A
430B
430B
430B
430B
430B
430B
460A
460A
460A
460A
460A
460A
460B
460B
460B
460B
460B
460B
490A
490A
490A
490A
490A
490A
490B
490B
490B
490B
490B
490B
460A
460A
460A
460A
460B

LT30
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
RT
LT0
LT20
LT30
LT40
LT50
LT20
LT30
LT50
LT60
LT20

Plant Design System (PDS) Reference Data Manager (PD_Data)

455

Appendix: Codelists
6297
6298
6299
6300
6301
6302
6303
6304
6305

=
=
=
=
=
=
=
=
=

BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225
BS1501-225

460B
460B
460B
490A
490A
490A
490B
490B
490B

LT30
LT50
LT60
LT20
LT30
LT50
LT20
LT30
LT50

steel plates BS1501 part 2 1988


6310 = BS1501-243
6311 = BS1501-271
6312 = BS1501-281
6313 = BS1501-620
6314 = BS1501-621
6315 = BS1501-622-515
6316 = BS1501-622-690
6317 = BS1501-660
6318 = BS1501-503
6319 = BS1501-510
6320 = BS1501-828
steel plates BS1501 part 3 1973
6321 = BS1501-403S17A
6322 = BS1501-405S17A
6323 = BS1501-304S12A
6324 = BS1501-304S15A
6325 = BS1501-304S49A
6326 = BS1501-321S12A
6327 = BS1501-321S49A
6328 = BS1501-347S17A
6329 = BS1501-347S49A
6330 = BS1501-316S12A
6331 = BS1501-316S16A
6332 = BS1501-316S37A
6333 = BS1501-316S49A
6334 = BS1501-320S17A
6335 = BS1501-310S24A
6336 = BS1501-NA15A
6337 = BS1501-NA16A
6338 = BS1501-460S52A
6339 = BS1501-304S62A
6340 = BS1501-304S65A
6341 = BS1501-304S87A
6342 = BS1501-347S67A
6343 = BS1501-316S62A
6344 = BS1501-316S66A
6345 = BS1501-316S82A
6351 = BS1501-403S17B
6352 = BS1501-405S17B
6353 = BS1501-304S12B
6354 = BS1501-304S15B
6355 = BS1501-304S49B

456

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1501-351S12B
BS1501-351S49B
BS1501-347S17B
BS1501-347S49B
BS1501-316S12B
BS1501-316S16B
BS1501-316S37B
BS1501-316S49B
BS1501-320S17B
BS1501-310S24B
BS1501-NA15B
BS1501-NA16B
BS1501-460S52B
BS1501-304S62B
BS1501-304S65B
BS1501-304S87B
BS1501-377S67B
BS1501-316S62B
BS1501-316S66B
BS1501-316S82B
BS1501-460S52A LT70

steel forgings
6380 = BS1503
6381 = BS1503
6382 = BS1503
6383 = BS1503
6384 = BS1503
6385 = BS1503
6386 = BS1503
6387 = BS1503
6388 = BS1503
6389 = BS1503
6390 = BS1503
6391 = BS1503
6392 = BS1503
6393 = BS1503
6394 = BS1503
6395 = BS1503
6396 = BS1503
6397 = BS1503
6398 = BS1503
6399 = BS1503
6400 = BS1503
6401 = BS1503
6402 = BS1503
6403 = BS1503
6404 = BS1503
6405 = BS1503
6406 = BS1503
6407 = BS1503
6408 = BS1503
6409 = BS1503
6410 = BS1503

to BS1503 1980
164-490
221-410
221-430
221-460
221-490
221-510
221-530
221-550
223-410
223-430
223-460
223-490
223-510
224-410
224-430
224-460
224-490
224-510
245-420
620-440
620-540
621-460
660-460
271-560
622-490
622-560
622-650
625-520
625-590
503-490
509-690

Plant Design System (PDS) Reference Data Manager (PD_Data)

457

Appendix: Codelists

458

6411
6412
6413
6414

=
=
=
=

BS1503
BS1503
BS1503
BS1503

410S21
420S29
403S17
405S17

6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

304S11
304S31
304S51
347S31
347S51
321S31
321S51-490
321S51-510
316S11
316S13
316S31
316S33
316S51
320S33
310S31

6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

164-490E
221-430E
221-460E
221-490E
221-510E
221-530E
221-550E
223-410E
223-430E
223-460E
223-490E
223-510E
224-410E
224-430E
224-460E
224-490E
224-510E

6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

245-420E
620-440E
620-540E
621-460E
660-460E
271-560E
622-490E
622-560E
622-650E
625-520E
625-590E
410S21E
420S29E
403S17E
405S17E

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474

=
=
=
=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

304S11E
304S31E
304S51E
347S31E
347S51E
321S31E
321S51-490E
321S51-510E
316S11E
316S13E
316S31E
316S33E
316S51E

6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

223-410-LT10
223-410-LT20
223-410-LT50
223-430-LT10
223-430-LT15
223-430-LT40
223-460-LT0
223-460-LT10
223-460-LT20
223-490-LT0
223-490-LT10
223-510-LT0
224-410-LT10
224-410-LT20
224-410-LT50
224-430-LT10
224-430-LT15
224-430-LT40
224-460-LT0
224-460-LT10
224-460-LT20
224-490-LT0
224-490-LT10
224-510-LT0

6499 = BS1503 503-490-LT80


6500 = BS1503 509-690-LT196
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510

=
=
=
=
=
=
=
=
=
=

BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503
BS1503

304S11-LT196
304S31-LT196
347S31-LT196
321S31-LT196
321S51-490
321S51-510
316S11-LT196
316S13-LT196
316S31-LT196
316S33-LT196

Plant Design System (PDS) Reference Data Manager (PD_Data)

459

Appendix: Codelists
steel casting to BS1504 1976
6520 = BS1504-161 grade 430A
6521 = BS1504-161 grade 480A
6522 = BS1504-161 grade 540A
6523 = BS1504-161 grade 430E
6524 = BS1504-161 grade 480E
6525 = BS1504-161 grade 430A-LT40
6526 = BS1504-245A
6527 = BS1504-245B
6528 = BS1504-245A-LT50
6529 = BS1504-503-LT60
6530 = BS1504-621A
6531 = BS1504-622A
6532 = BS1504-622E
6533 = BS1504-623A
6534 = BS1504-625A
6535 = BS1504-625E
6536 = BS1504-629A
6537 = BS1504-660A
6538 = BS1504-420C29A
6539 = BS1504-425C11A
6540 = BS1504-304C15A
6541 = BS1504-304C15A-LT196
6542 = BS1504-304C12A
6543 = BS1504-304C12A-LT196
6544 = BS1504-347C17A
6545 = BS1504-347C17A-LT196
6546 = BS1504-315C16A
6547 = BS1504-315C16A-LT196
6548 = BS1504-316C12A
6549 = BS1504-316C16A
6550 = BS1504-316C71A
6551 = BS1504-318C17A
6552 = BS1504-316C16E
6553 = BS1504-316C71E
6554 = BS1504-316C12A-LT196
6555 = BS1504-316C16A-LT196
6556 = BS1504-316C71A-LT196
6557 = BS1504-317C12A
6558 = BS1504-317C16A
6559 = BS1504-364C11A
6560 = BS1504-332C11A
6561 = BS1504-310C40A
6562 = BS1504-330C11A
steel bars and billets for bolting BS1506 1986
6570 = BS1506-162
6571 = BS1506-253
6572 = BS1506-253-LT100
6573 = BS1506-509-650
6574 = BS1506-509-650-LT196
6575 = BS1506-509-690
6576 = BS1506-509-690-LT196
6577 = BS1506-630-790

460

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS1506-630-790-LT100
BS1506-630-790-LT75
BS1506-630-860
BS1506-630-860-LT100
BS1506-630-690
BS1506-630-690-LT100
BS1506-631-850
BS1506-670-860
BS1506-671-850
BS1506-681-820
BS1506-410S21-690
BS1506-410S21-720
BS1506-410S21-760
BS1506-410S21-750
BS1506-410S21-770
BS1506-416S29
BS1506-286S31
BS1506-286S31-LT196
BS1506-304S31
BS1506-304S31-LT196
BS1506-304S51
BS1506-304S61
BS1506-304S61-LT196
BS1506-304S71
BS1506-304S71-LT196
BS1506-303S22
BS1506-316S31
BS1506-316S31-LT196
BS1506-316S33
BS1506-316S33-LT196
BS1506-316S51
BS1506-316S53
BS1506-316S61
BS1506-316S61-LT196
BS1506-316S63
BS1506-316S63-LT196
BS1506-316S65
BS1506-316S65-LT196
BS1506-316S67
BS1506-316S67-LT196
BS1506-321S31
BS1506-321S31-LT196
BS1506-321S51-490
BS1506-321S51-520
BS1506-347S31
BS1506-347S31-LT196
BS1506-347S51

7999 = undefined

Plant Design System (PDS) Reference Data Manager (PD_Data)

461

Appendix: Codelists

CL148, Piping Materials Class Description (31999)


NOTE: Codelist numbers 2-7999 are reserved for values that apply
to US practices. Codelist numbers 8000-31999 are reserved for
values that apply to practices in other countries.
1 = [Blank]
US Piping Material Class Descriptions, 2-7999
Irons, F
2 = [FAY1W8] [8F0002] Gravity Head, Gray CI
3 = [FDYLW8] [8F0003] Gravity Head, DI Cement Lined
6 = [FDYLU9] [9F0006] AWWA 150# MJ, DI Cement Lined
Carbon Steels, C
14 = [CAA5UA] [AC0014] CL125 FFFE, CS, Brnz Trim
16 = [CAA5VA] [AC0016] CL125 FFFE, Brnz Trim
19 = [CAALV1] [1C0019] CL150 FFFE, CS Cement Lined
31 = [CAC5C1] [1C0031] CL150 RFFE, CS, Trim 8
32 = [CAC5C2] [2C0032] CL300 RFFE, CS, Trim 8
33 = [CAC5C4] [4C0033] CL600 RFFE, CS, Trim 8
35 = [CAC5G1] [1C0035] CL150 RFFE, CS, Trim 8
43 = [CAC5Q1] [1C0043] CL150 RFFE, CS, Trim 8, (ANSI-B31.1)
45 = [CAC5R1] [1C0045] CL150 RFFE, CS, Trim 8
48 = [CAC5U1] [1C0048] CL150 RFFE, CS, Trim 8
49 = [CAC7C1] [1C0049] CL150 RFFE, CS, Trim 8
50 = [CAC7C2] [2C0050] CL300 RFFE, CS, Trim 8
51 = [CAC7C4] [4C0051] CL600 RFFE, CS, Trim 8
65 = [CAC8C1] [1C0065] CL150 RFFE, CS, Trim 8
66 = [CAC8C2] [2C0066] CL300 RFFE, CS, Trim 8
73 = [CAC9C1] [1C0073] CL150 RFFE, CS, Trim 8
74 = [CAC9C2] [2C0074] CL300 RFFE, CS, Trim 8
75 = [CAC9C4] [4C0075] CL600 RFFE, CS, Trim 8
76 = [CAC9C5] [5C0076] CL900 RFFE, CS, Trim 8
105 = [CAD7K1] [1C0105] CL150 RFFE, CS, Trim 9
106 = [CAD7K2] [2C0106] CL300 RFFE, CS, Trim 9
146 = [CAF5S1] [1C0146] CL150 RFFE, CS, SS/TFE Trim
153 = [CAF7J1] [1C0153] CL150 RFFE, CS, Trim 13
171 = [CAFYC1] [1C0171] CL150 RFFE, CS, 316 Trim
176 = [CAH5C1] [1C0176] CL150 RFFE-SF, CS, Trim 8
177 = [CAH5C2] [2C0177] CL300 RFFE-SF, CS, Trim 8
182 = [CAH5G1] [1C0182] CL150 RFFE-SF, CS, Trim 8
183 = [CAH5G2] [2C0183] CL300 RFFE-SF, CS, Trim 8
185 = [CAH7C1] [1C0185] CL150 RFFE-SF, CS, Trim 8
186 = [CAH7C2] [2C0186] CL300 RFFE-SF, CS, Trim 8
320 = [CALYC2] [2C0320] CL300 RFFE-SF, CS, 316 Trim
389 = [CAU5P4] [4C0389] CL600 BE/RFFE, CS, Trim 8, (ASME-I)
390 = [CAU5P5] [5C0390] CL900 BE/RFFE, CS, Trim 5, (ASME-I)
391 = [CAU5P6] [6C0391] CL1500 BE/RJFE, CS, Trim 5, (ASME-I)
394 = [CAU5Q2] [2C0394] CL300 BE/RFFE, CS, Trim 8, (ANSI-B31.1)
395 = [CAU5Q4] [4C0395] CL600 BE/RFFE, CS, Trim 8, (ANSI-B31.1)
396 = [CAU5Q5] [5C0396] CL900 BE/RFFE, CS, Trim 5, (ANSI-B31.1)

462

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
397
400
401
402
403
405
407
458
459
460
461
548
549
551
557
564
577
593
600
601
602
609
610
611
618
619
620
630
722
723
724
730
731
732
785
794
800
803
841
842

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[CAU5Q6]
[CAU5R2]
[CAU5R4]
[CAU5R5]
[CAU5R6]
[CAU5RF]
[CAU7C6]
[CAYYC1]
[CAYYC2]
[CDA1U1]
[CDA5U1]
[CJD7K1]
[CJD7K2]
[CJD7K5]
[CJD8K2]
[CJD9K1]
[CJE7C2]
[CJE9C2]
[CJF5C1]
[CJF5C2]
[CJF5C4]
[CJF7C1]
[CJF7C2]
[CJF7C4]
[CJF9C1]
[CJF9C2]
[CJF9C4]
[CJH7C4]
[CJL7C2]
[CJL7C4]
[CJL7C5]
[CJL9C2]
[CJL9C4]
[CJL9C5]
[CJU7C6]
[CJV5C6]
[CJV7C6]
[CJV7K6]
[CPD5D1]
[CPD5D2]

[6C0397]
[2C0400]
[4C0401]
[5C0402]
[6C0403]
[FC0405]
[6C0407]
[1C0458]
[2C0459]
[1C0460]
[1C0461]
[1C0548]
[2C0549]
[5C0551]
[2C0557]
[1C0564]
[2C0577]
[2C0593]
[1C0600]
[2C0601]
[4C0602]
[1C0609]
[2C0610]
[4C0611]
[1C0618]
[2C0619]
[4C0620]
[4C0630]
[2C0722]
[4C0723]
[5C0724]
[2C0730]
[4C0731]
[5C0732]
[6C0785]
[6C0794]
[6C0800]
[6C0803]
[1C0841]
[2C0842]

CL1500 BE/RJFE, CS, Trim 5, (ANSI-B31.1)


CL300 BE/RFFE, CS, Trim 8, (ANSI-B31.3)
CL600 BE/RFFE, CS, Trim 8, (ANSI-B31.3)
CL900 BE/RFFE, CS, Trim 5, (ANSI-B31.3)
CL1500 BE/RJFE, CS, Trim 5, (ANSI-B31.3)
CL800 BE/RFFE, CS, Trim 5, (ANSI-B31.3)
CL1500 BE/RJFE, CS, Trim 8
CL150 BE, CS
CL300 BE, CS
CL150 FFFE, Galv CS, Brnz Trim
CL150 FFFE, Galv CS, Brnz Trim
CL150 RFFE, Killed CS, Trim 12
CL300 RFFE, Killed CS, Trim 12
CL900 RFFE, Killed CS, Trim 12
CL300 RFFE, Killed CS, Trim 12
CL150 RFFE, Killed CS, Trim 12
CL300 RFFE, Killed CS, NACE, Trim 9
CL300 RFFE, Killed CS, NACE, Trim 9
CL150 RFFE, Killed CS, NACE, Trim 12
CL300 RFFE, Killed CS, NACE, Trim 12
CL600 RFFE, Killed CS, NACE, Trim 12
CL150 RFFE, Killed CS, NACE, Trim 12
CL300 RFFE, Killed CS, NACE, Trim 12
CL600 RFFE, Killed CS, NACE, Trim 12
CL150 RFFE, Killed CS, NACE, Trim 12
CL300 RFFE, Killed CS, NACE, Trim 12
CL600 RFFE, Killed CS, NACE, Trim 12
CL600 RFFE-SF, Killed CS, Trim 8
CL300 RFFE-SF, Killed CS, NACE, Trim 12
CL600 RFFE-SF, Killed CS, NACE, Trim 12
CL900 RFFE-SF, Killed CS, NACE, Trim 12
CL300 RFFE-SF, Killed CS, NACE, Trim 12
CL600 RFFE-SF, Killed CS, NACE, Trim 12
CL900 RFFE-SF, Killed CS, NACE, Trim 12
CL1500 BE/RJFE, Killed CS, Trim 8
CL1500 BE/RJFE, Killed CS, Trim 8
CL1500 BE/RJFE, Killed CS, NACE, Trim 12
CL1500 BE/RJFE, Killed CS, Trim 12
CL150 RFFE, Low Temp CS, Trim 2
CL300 RFFE, Low Temp CS, Trim 2

Low and Intermediate Alloy Steels, L


1669 = [LPFYG2] [2L1669] CL300 RFFE, 1.25Cr-0.5Mo, 316 Trim
1670 = [LPTYG2] [2L1670] CL300 RFFE, 1.25Cr-0.5Mo, 316 Trim
1671 = [LPH5B1] [1L1671] CL150 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1672 = [LPH5B2] [2L1672] CL300 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1673 = [LPH5B4] [4L1673] CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1677 = [LPH7B1] [1L1677] CL150 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1678 = [LPH7B2] [2L1678] CL300 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1679 = [LPH7B4] [4L1679] CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1691 = [LPH9B4] [4L1691] CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8
1864 = [LPU5B6] [6L1864] CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 8
1868 = [LPU5P5] [5L1868] CL900 BE/RFFE, 1.25Cr-0.5Mo, Trim 5, (ASME-I)
1869 = [LPU5P6] [6L1869] CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5, (ASME-I)

Plant Design System (PDS) Reference Data Manager (PD_Data)

463

Appendix: Codelists
1874
1875
1882
1885
3013
3014
3027
3028
3029
3040
3041
3042
3048
3049
3193
3203
3204
3390
3725
3726
3746
3747
3748
3749

= [LPU5Q5] [5L1874] CL900 BE/RFFE, 1.25Cr-0.5Mo, Trim 5, (ANSI-B31.1)


= [LPU5Q6] [6L1875] CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5, (ANSI-B31.1
= [LPU5R6] [6L1882] CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5, (ANSI-B31.3
= [LPU7B6] [6L1885] CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 8
= [LTC5B1] [1L3013] CL150 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC5B2] [2L3014] CL300 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC7B1] [1L3027] CL150 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC7B2] [2L3028] CL300 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC7B4] [4L3029] CL600 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC8B1] [1L3040] CL150 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC8B2] [2L3041] CL300 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC8B4] [4L3042] CL600 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC9B1] [1L3048] CL150 RFFE, 5Cr-0.5Mo, Trim 8
= [LTC9B2] [2L3049] CL300 RFFE, 5Cr-0.5Mo, Trim 8
= [LTH7B5] [5L3193] CL900 RFFE-SF, 5Cr-0.5Mo, Trim 8
= [LTH9B2] [2L3203] CL300 RFFE-SF, 5Cr-0.5Mo, NACE, Trim 8
= [LTH9B4] [4L3204] CL600 RFFE-SF, 5Cr-0.5Mo, NACE, Trim 8
= [LTU7B6] [6L3390] CL1500 BE/RJFE, 5Cr-0.5Mo, Trim 8
= [LVC7B1] [1L3725] CL150 RFFE, 9Cr-1Mo, Trim 8
= [LVC7B2] [2L3726] CL300 RFFE, 9Cr-1Mo, Trim 8
= [LVC9B1] [1L3746] CL150 RFFE, 9Cr-1Mo, Trim 8
= [LVC9B2] [2L3747] CL300 RFFE, 9Cr-1Mo, Trim 8
= [LVC9B4] [4L3748] CL600 RFFE, 9Cr-1Mo, Trim 8
= [LVC9B5] [5L3749] CL900 RFFE, 9Cr-1Mo, Trim 8

Stainless Steels, S
3977 = [SAC3T1] [1S3977]
3978 = [SAC3T2] [2S3978]
3979 = [SAC3T4] [4S3979]
3980 = [SAC3T5] [5S3980]
3984 = [SAD3C1] [1S3984]
3985 = [SAD3C2] [2S3985]
3988 = [SAD3E1] [1S3988]
3989 = [SAD3E2] [2S3989]
3991 = [SAD3F1] [1S3991]
4104 = [SAFYG1] [1S4104]
4218 = [SAM3T6] [6S4218]
4396 = [SBD3C2] [2S4396]
4488 = [SBF3U1] [1S4488]
5135 = [SED5C1] [1S5135]
5187 = [SEF3C1] [1S5187]
5188 = [SEF3C2] [2S5188]
5189 = [SEF3C4] [4S5189]
5197 = [SEF3G1] [1S5197]
6246 = [SHJ3B2] [2S6246]
6247 = [SHJ3B4] [4S6247]
6258 = [SHJ5B2] [2S6258]
6449 = [SHV3B5] [5S6449]
6450 = [SHV3B6] [6S6450]
6457 = [SHV5B6] [6S6457]

CL150 RFFE, 304/CS Valves, Trim 8


CL300 RFFE, 304/CS Valves, Trim 8
CL600 RFFE, 304/CS Valves, Trim 8
CL900 RFFE, 304/CS Valves, Trim 8
CL150 RFFE, 304/316 Valves, Trim 12
CL300 RFFE, 304/316 Valves, Trim 12
CL150 RFFE, 304, Trim 2
CL300 RFFE, 304, Trim 2
CL150 RFFE, 304, Trim 2
CL150 RFFE, 304, 316 Trim
CL1500 RJFE, 304/CS Valves, Trim 8
CL300 RFFE, 304L/316 Valves, Trim 12
CL150 RFFE, 304/316 Valves, Trim 2
CL150 RFFE, 316, Trim 12
CL150 RFFE, 316, Trim 12
CL300 RFFE, 316, Trim 12
CL600 RFFE, 316, Trim 12
CL150 RFFE, 316, Trim 12
CL300 RFFE-SF, 321/347 Valves, 347HF Trim
CL600 RFFE-SF, 321/347 Valves, 347HF Trim
CL300 RFFE-SF, 321/347 Valves, 347HF Trim
CL900 BE/RFFE-SF, 321/347 Valves, 347HF Trim
CL1500 BE/RJFE, 321/347 Valves, 347HF Trim
CL1500 BE/RJFE, 321/347 Valves, 347HF Trim

Copper Alloys, K
Nickel Alloys, N

464

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
7540 = [NGF5G1] [1N7540] CL150 RFFE, Inconel 600, Inconel Trim
Aluminum Alloys, A
Other Materials, X
7687 = [XCY1W8] [8X7687] Gravity Head, Vitrified Clay
7689 = [XEY1W8] [8X7689] Gravity Head, Reinforced Concrete
7733 = [XTY1U9] [9X7733] SCH-80, SE, PVC
European Piping Material Class Descriptions, 8000-9999
8000 = Carbon steel
8001 = Stainless steel
8002 = Forged steel
8010 = Ferritic steel
8011 = Austenitic steel
8020 = Plastic
8021 = Fiber glass
8030 = Glass lined
8031 = Cement lined
8032 = Chloroprene (CR) lined
9999 = Undefined
The names of Piping Materials Classes are determined as follows:
o A list includes possible Piping Materials Classes. It consists of six
character names which are established on the basis of the naming convention
ABCDEF. The meaning of each of the characters in this code is defined below.
Corresponding values are given in the lists included in subsequent pages.
A.......materials group
B.......materials type
C.......detail features
D.......corrosion allowance or type of lining
E.......service description
F.......pressure rating
o The name of a Piping Materials Class is then determined from the convention
FAXXX, where:
F.......pressure rating
A.......material group
XXX.....sequence number from list in 2090-41-SN
MATERIALS GROUP AND TYPE: (1st and 2nd character)
Irons, F
A= Gray iron
D= Ductile iron
G= Ferritic ductile iron
J= Austenitic ductile iron
Z= Other 1
Carbon Steels, C
A= CS
D= CS, galvanized

Plant Design System (PDS) Reference Data Manager (PD_Data)

465

Appendix: Codelists
G=
J=
M=
P=
X=
Y=
Z=

CS, jacketed
CS, killed
CS, killed, jacketed
CS, low temp
Other 1
Other 2
Other 3

Low and Intermediate Alloys, L


A= 2Ni-1Cu
C= 3.5Ni
D= 5Ni
G= 9Ni
J= C-0.5Mo
M= 0.75Cr-0.5Mo
N= 1Cr-0.5Mo
P= 1.25Cr-0.5Mo
Q= 2Cr-0.5Mo
R= 2.25Cr-1Mo
S= 3Cr-1Mo
T= 5Cr-0.5Mo
U= 7Cr-0.5Mo
V= 9Cr-1Mo
X= Other 1
Y= Other 2
Z= Other 3
Stainless Steels, S
A= 304
B= 304L
C= 304H
D= 310
E= 316
F= 316L
G= 316H
H= 321
J= 321H
K= 410S
L= CHP10
M= CHP20
N= CPF10MC
O= CPH8
P= CPK20
Q= UNS S31200
R= UNS S31250
S= UNS S31500
T= UNS S31803
U= UNS S32304
V= UNS S32550
W= Alloy 20
X= Other 1
Y= Other 2
Z= Other 3

466

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
Copper Alloys, K
A= Brass
F= Bronze
K= Copper
P= 90Cu-10Ni
R= 70Cu-30Ni
X= Other 1
Y= Other 2
Z= Other 3
Nickel Alloys, N
A= Low C Ni
D= Monel
E= K-Monel
F= R-Monel
G= Inconel 600
H= Inconel 601
J= Inconel 625
L= Incoloy 800
M= Incoloy 800H
N= Incoloy 801
P= Incoloy 802
Q= Incoloy 825
T= Hastelloy B
U= Hastelloy C
V= Hastelloy G
X= Other 1
Y= Other 2
Z= Other 3
Aluminum Alloys, A
C= 3002 aluminum
D= 3003 aluminum
E= 3004 aluminum
F= 5050 aluminum
G= 5052 aluminum
Q= 6061 aluminum
R= 6063 aluminum
S= Alclad
X= Other 1
Y= Other 2
Z= Other 3
Other Materials, X
A= Asbestos cement
B= Borosilicate glass
C= Clay, vitrified
D= Concrete, prestressed
E= Concrete, reinforced
F= CPVC
G= Epoxy/Glass fib
J= Furan/Carbon
K= Furan/Glass fib
L= Kynar

Plant Design System (PDS) Reference Data Manager (PD_Data)

467

Appendix: Codelists
N=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

Nylon
Polyester/Glass fib
Polyethylene, high dens
Polyethylene, low dens
Polypropylene
PVC
Teflon
Titanium
Zirconium
Other 1
Other 2
Other 3

MATERIALS CLASS DETAILS: (3rd character)


A=
B=
C=
D=
E=
F=
G=
H=
J=
K=
L=
M=
N=
0=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

Std FF, std trim


Std FF, other
Std RF, std trim
Std RF, SS trim
Std RF, Monel trim
Std RF, other
Std RF, other
RFSF, std trim
RFSF, SS trim
RFSF, Monel trim
RFSF, other
RTJ, std trim
RTJ, SS trim
RTJ, Monel trim
RTJ, other
MJ, std trim
MJ, SS trim
MJ, Monel trim
MJ, other
BE, std trim
BE, SS trim
BE, Monel trim
BE, other
Other 1
Other 2

CA OR LINING TYPE: (4th character)


1=
2=
3=
4=
5=
6=
7=
8=
9=
A=
B=

468

None
0.020"
0.030"
0.050"
0.063"
0.10"
0.125"
0.188"
0.250"
405 clad
410S clad

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
C=
D=
E=
F=
G=
H=
J=
L=
M=
N=
O=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

304 clad
304L clad
316 clad
316L clad
317 clad
317L clad
321 clad
Cement lined
Epoxy lined
Glass lined
Kynar lined
Polyester lined
Polypropylene lined
PTFE lined
Saran lined
Teflon lined
TK31 lined
R11 lined
R15 lined
R18 lined
Other 1
Other 2

SERVICE: (5th character)


A=
B=
C=
D=
E=
F=
G=
H=
J=
K=
L=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

Process, hottest (-20 to 1500+/- degF)


Process, hotter (-20 to 1000+/- degF)
Process, hot (-20 to 800 degF)
Process, cold (-20 to -50 degF)
Process, colder (-20 to -150 degF)
Process, coldest (-20 to -425 degF)
Process, other
Category M
Acid
Caustic/Amine
LPG
Steam ASME-I
Steam B31.1
Steam B31.3
Fuel gas, fuel oil
Lube oil, seal oil
Category D
Firewater
Sewer
Instrument
Other 1
Other 2

RATING: (6th character)


1=
2=
3=
4=

CL150
CL300
CL400
CL600

Plant Design System (PDS) Reference Data Manager (PD_Data)

469

Appendix: Codelists
5=
6=
7=
8=
9=
A=
F=
G=
H=
J=
K=
L=
M=
N=
R=
T=
V=

CL900
CL1500
CL2500
GRAVHD
OTHER
CL125
CL800
CL2000
CL3000
CL4500
CL5000
CL6000
CL9000
CL10000
CL15000
CL20000
CL30000

CL160, Responsibility (25)


1 = [Blank]
2 = By Contractor
3 = By Owner
4 = By A
5 = By B
6 = By C
7 = By D
8 = By E
9 = By Equip Vendor
10 = By Vendor
15 = By Piping
16 = By Instruments
25 = By Others

CL180, Fabrication Category (99)


NOTE: Some data displays require that only values to the left of
the "=" sign be shown; other reports require that only values to the
right of the "=" sign be displayed.
1 = [Blank]
5 = CSSF, Contractor supplied, shop fabricated
7 = CSFF, Contractor supplied, field fabricated
15 = SSSF, Shop supplied, shop fabricated
17 = SSFF, Shop supplied, field fabricated
25 = FSSF, Field supplied, shop fabricated
27 = FSFF, Field supplied, field fabricated
35 = ASSF, A supplied, shop fabricated
37 = ASFF, A supplied, field fabricated

470

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
45
47
95
97

=
=
=
=

BSSF,
BSFF,
OSSF,
OSFF,

B supplied, shop fabricated


B supplied, field fabricated
Owner supplied, shop fabricated
Owner supplied, field fabricated

CL190, Coating Requirements (99)


1 = [Blank]
2 = None
3 = Galv
4 = PS1.04
5 = PS1.07
6 = PS1.08
7 = PS1.09
8 = PS1.10
9 = PS1.11
10 = PS1.12
11 = PS1.13
12 = PS2.03
13 = PS2.05
14 = PS4.01
15 = PS4.02
16 = PS4.03
17 = PS4.04
18 = PS4.05
19 = PS8.01
20 = PS9.01
21 = PS10.01
22 = PS10.02
23 = PS11.01
24 = PS12.01
25 = PS13.01
26 = PS14.01
27 = PS16.01
28 = PS18.01
40 = Varies

CL200, Heat Tracing Requirements (10)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values.
1
2
3
4

=
=
=
=

[Blank]
NT
[Not heat traced]
HT
[Heat traced]
PHT
[Partially heat traced]

Plant Design System (PDS) Reference Data Manager (PD_Data)

471

Appendix: Codelists

CL210, Heat Tracing Media (60)


NOTE: Codelist numbers 3-39 have been reserved for heat tracing
media used for non-jacketed pipe heat tracing. Codelist numbers
40-60 have been reserved for heat tracing media used for jacketed pipe
heat tracing. It is important that this allocation be respected.
1 = [Blank]
2 = N
[None]
For Non Jacketed Pipe Heat Tracing, 3-39
3 = E
[Electric]
10 = FA
[Heat transfer fluid A]
11 = FB
[Heat transfer fluid B]
12 = FC
[Heat transfer fluid C]
16 = I
[Impedance]
17 = MI
[Magnetic induction]
18 = SKE
[Skin effect]
20 = SH
[Steam high pressure, CL900]
21 = SL
[Steam low pressure, CL150]
22 = SM
[Steam medium pressure, CL600]
23 = SN
[Steam normal pressure, CL300]
24 = SS
[Steam superheated]
For Jacketed Pipe Heat Tracing, 40-60
40 = FAJ
[Heat transfer fluid A]
41 = FBJ
[Heat transfer fluid B]
42 = FCJ
[Heat transfer fluid C]
50 = SHJ
[Steam high pressure, CL900]
51 = SLJ
[Steam low pressure, CL150]
52 = SMJ
[Steam medium pressure, CL600]
53 = SNJ
[Steam normal pressure, CL300]
54 = SSJ
[Steam superheated]

CL220, Insulation Purpose (40)


1 = [Blank]
2 = N
3 = P
4 = H
5 = HS
11 = HF
14 = AS
15 = C
16 = CV
17 = CS
18 = CH
20 = CF
21 = S
22 = SV

472

[Not insulated]
[Personnel protection insulated]
[Hot insulated]
[Hot insulated with sound attenuation]
[Hot insulated with fire protection]
[Anti-sweat insulated]
[Cold insulated]
[Cold insulated vacuum type]
[Cold insulated with sound attenuation]
[Cold and hot insulated]
[Cold insulated with fire protection]
[Sound attenuation insulated]
[Sound attenuation insulation with vapor barrier]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
30
32
34
40

=
=
=
=

R11 [Refractory lined, insulation]


R15 [Refractory lined, insulation/erosion]
R18 [Refractory lined, erosion]
Varies

CL230, Cleaning Requirements (99)


1 = [Blank]
2 = None
3 = CC1
4 = CC2
5 = CC3
6 = CC4
7 = CC5
15 = Varies

CL330, CP Type/Termination/Preparation (999)


NOTE: Use 2-199 for bolted types; 300-399 for male types and
400-599 for female types. Refer to Reference Data Manager
(PD_DATA) Reference Guide for additional data.
1 = [Blank]
2 = FE

[Flanged end]

Use 11-15 for ends without integral


integral gaskets.
10 = FFTP
(11-19) [Flat-face
11 = FFFE
[Flat-face
16 = FFFEWG
[Flat-face

gaskets; 16-19 for ends with


flanged termination type]
flanged end]
flanged end with integral gasket]

Use 21-25 for ends without integral gaskets; 26-29 for ends with
integral gaskets.
20 = RFTP
(21-29) [Raised-face flanged termination type]
21 = RFFE
[Raised-face flanged end]
26 = RFFEWG
[Raised-face flanged end with integral gasket]
Use 31-35 for ends without integral gaskets; 36-39 for ends with
integral gaskets.
30 = RJFTP
(31-39) [RTJ-face flanged termination type]
31 = RJFE
[RTJ-face flanged end]
Use 41-45 for ends without integral gaskets; 46-49 for ends with
integral gaskets.
40 = TMFTP
(41-49) [Tongue/male-face flanged termination type]
41 = STFE
[Small-tongue-face flanged end]
42 = LTFE
[Large-tongue-face flanged end]
43 = SMFE
[Small-male-face flanged end]
44 = LMFE
[Large-male-face flanged end]

Plant Design System (PDS) Reference Data Manager (PD_Data)

473

Appendix: Codelists
Use 51-55 for ends without integral gaskets; 56-59 for ends with
integral gaskets.
50 = GFFTP
(51-59) [Groove/female-face flanged termination type]
51 = SGFE
[Small-groove-face flanged end]
52 = LGFE
[Large-groove-face flanged end]
53 = SFFE
[Small-female-face flanged end]
54 = LFFE
[Large-female-face flanged end]
Use 61-65 for lap-flanged ends without integral gaskets; 66-69 for
lap-flanged ends with integral gaskets.
60 = FFLFTP
(61-69) [Flat-face lap-flanged termination type]
61 = FFLFE
[Flat-face lap-flanged end]
Use 71-75 for lap-flanged ends without integral gaskets; 76-79 for
lap-flanged ends with integral gaskets.
70 = RFLFTP
(71-79) [Raised-face lap-flanged termination type]
71 = RFLFE
[Raised-face lap-flanged end]
Use 81-85 for lap-flanged ends without integral gaskets; 86-89 for
lap-flanged ends with integral gaskets.
80 = RJFLFTP
(81-89) [RTJ-face lap-flanged termination type]
81 = RJLFE
[RTJ-face lap-flanged end]
Use 91-95 for lap-flanged ends without integral gaskets; 96-99 for
lap-flanged ends with integral gaskets.
90 = TMFLFTP
(91-99) [Tongue/male-face lap-flanged termination type]
91 = STLFE
[Small-tongue-face lap-flanged end]
92 = LTLFE
[Large-tongue-face lap-flanged end]
93 = SMLFE
[Small-male-face lap-flanged end]
94 = LMLFE
[Large-male-face lap-flanged end]
Use
for
100
101
102
103
104

101-105 for lap-flanged ends without integral gaskets; 106-109


lap-flanged ends with integral gaskets.
= GFFLFTP (101-109)[Groove/female-face lap-flanged termination type]
= SGLFE
[Small-groove-face lap-flanged end]
= LGLFE
[Large-groove-face lap-flanged end]
= SFLFE
[Small-female-face lap-flanged end]
= LFLFE
[Large-female-face lap-flanged end]

Use 111-115 for ends without integral gaskets; 116-119 for ends
with integral gaskets.
110 = FFTBTP (111-119)[Flat-face thru-bolted termination type]
111 = FFTBE
[Flat-face thru-bolted end]
116 = FFTBEWG
[Flat-face thru-bolted end with integral gasket]
Use 121-125 for ends without integral
with integral gaskets.
120 = RFTBTP (121-129)[Raised-face
121 = RFTBE
[Raised-face
126 = RFTBEWG
[Raised-face
gasket]

gaskets; 126-129 for ends


thru-bolted termination type]
thru-bolted end]
thru-bolted end with integral

Use 131-135 for ends without integral gaskets; 136-139 for ends

474

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
with integral gaskets.
130 = RJTBTP (131-139)[RTJ-face thru-bolted termination type]
131 = RJTBE
[RTJ-face thru-bolted end]
Use 141-145 for ends without integral gaskets; 146-149 for ends
with integral gaskets.
140 = MRJTBTP (141-149)[Male RTJ-face thru-bolted termination type]
146 = MRJTBEWG
[Male RTJ-face thru-bolted end with integral
gasket]
Use 151-155 for ends without integral gaskets; 156-159 for ends
with integral gaskets.
150 = FFTBCSTP (151-159)[Flat-face thru-bolted-with-cap-screws
termination ty
151 = FFTBCSE
[Flat-face thru-bolted-with-cap-screws end]
156 = FFTBCSEWG
[Flat-face thru-bolted-with-cap-screws end with
integ
Use 161-165 for ends without integral gaskets; 166-169 for ends
with integral gaskets.
160 = RFTBCSTP (161-169)[Raised-face thru-bolted-with-cap-screws
termination
161 = RFTBCSE
[Raised-face thru-bolted-with-cap-screws end]
166 = RFTBCSEWG
[Raised-face thru-bolted-with-cap-screws end
with int
Use 171-175 for ends without integral gaskets; 176-179 for ends
with integral gaskets.
170 = RJTBCSTP (171-179)[RTJ-face thru-bolted-with-cap-screws
termination typ
171 = RJTBCSE
[RTJ-face thru-bolted-with-cap-screws end]
Use 181-185 for ends without integral gaskets; 186-189 for ends
with integral gaskets.
180 = FFFTBTP (181-189)[Flat-full-face thru-bolted termination type]
181 = FFFTBE
[Flat-full-face thru-bolted end]
186 = FFFTBEWG
[Flat-full-face thru-bolted end with integral
gasket]
190 = MJTP
191 = MJE

(190-199)[Mechanical joint termination type]


[Mechanical joint end]

300 = MTP (301-399)[Male termination type]


Use 301-309 for welded ends only
301 = BE
[Beveled end]
302 = OLET
[Olet beveled end]
Use
311
321
331
341
351

311-319 for welded ends only


= TBE
[Tapered and beveled end]
= MFE
[Male flared end]
= MTE
[Male threaded end]
= MGE
[Male grooved end]
= MQCE
[Male quick connect end]

Plant Design System (PDS) Reference Data Manager (PD_Data)

475

Appendix: Codelists
355
361
371
381

=
=
=
=

MCE
MFRE
MHE
SPE

[Male clamp end]


[Male ferrule end]
[Male hose end]
[Spigot end]

Use
391
393
395

391-399 for welded ends


= PE (391-399)[Plain
= 3"FFPE
[Plain
= 6"FFPE
[Plain

only
end]
end, 3" field fit]
end, 6" field fit]

400 = STP (401-409)[Socket termination type]


401 = SE
[Socket end]
Use 421-429 for welded ends only
420 = SWTP (421-429)[Socketwelded termination type]
421 = SWE
[Socketwelded end]
440 = FTTP (441-449)[Female threaded termination type]
441 = FTE
[Female threaded end]
460 = FGTP (461-469)[Female grooved termination type]
461 = FGE
[Female grooved end]
470 = FCTP (471-479)[Female clamp termination type]
471 = FCE
[Female clamp end]
480 = FQCTP (481-489)[Female quick connect termination type]
481 = FQCE
[Female quick connect end]
500 = FFRTP (501-509)[Female ferrule termination type]
501 = FFRE
[Female ferrule end]
520 = FHTP (521-529)[Female hose termination type]
521 = FHE
[Female hose end]
540 = BLTP (541-549)[Bell end termination type]
541 = BLE
[Push-on bell end]
542 = MJBE
[Mechanical joint bell end]
590 = HTP

(581-599)[Hole end termination type]

Use 591-599 for welded ends only


591 = HCE
[Circular hole end]
600 = NTP
601 = NE

(600-605)[Null termination type]


[Null end]

650 = UDTP (651-659)[User defined termination type]


651 = UD
[User defined end] (When a "UD"
preparation end is detected by the
system in the piping materials
class, it will prompt the User to define
the actual CP preparation to use. The
value provided by the User will be used

476

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
for initial placement of the component
as well as for subsequent recreations of
the piping system.)

CL332, Schedule / Thickness Override


NOTE: Schedule/thickness override values for metric projects must
have codelist values between 499 and 1000.
1 = [Blank]
10 = .0625
11 = .125
12 = .1875
13 = .25
14 = .3125
15 = .375
16 = .4375
17 = .5
18 = .5625
19 = .625
20 = .6875
21 = .75
22 = .8125
23 = .875
24 = .9375
25 = 1
30 = 1.0625
31 = 1.125
32 = 1.1875
33 = 1.25
34 = 1.3125
35 = 1.375
36 = 1.4375
37 = 1.5
38 = 1.5625
39 = 1.625
40 = 1.6875
41 = 1.75
42 = 1.8125
43 = 1.875
44 = 1.9375
45 = 2
50 = 2.0625
51 = 2.125
52 = 2.1875
53 = 2.25
54 = 2.3125
55 = 2.375
56 = 2.4375
57 = 2.5
58 = 2.5625

Plant Design System (PDS) Reference Data Manager (PD_Data)

477

Appendix: Codelists
59 = 2.625
60 = 2.6875
61 = 2.75
62 = 2.8125
63 = 2.875
64 = 2.9375
65 = 3
100 = S-5S
101 = S-10S
102 = S-40S
103 = S-80S
110 = S-10
111 = S-20
112 = S-30
113 = S-40
114 = S-60
115 = S-80
116 = S-100
117 = S-120
118 = S-140
119 = S-160
130 = S-STD
131 = S-XS
132 = S-XXS

CL340, Safety Classification (99)


1 = [Blank]
2 = SC1
3 = SC2
4 = SC3
5 = SC4
6 = SC5
7 = SC6
8 = SC7
9 = SC8
10 = SC9

CL360, Stress Analysis Requirements (15)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1 = [Blank]
2 = ANR =Analysis not required
3 = ATBP=Analysis to be performed
4 = AC =Analysis completed

478

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL365, Reporting Requirements (25)


NOTE: In editing this codelist set, do not change the meaning of existing
codelist values.
1 = Reportable by MTO
2 = Not Reportable by MTO

CL366, Requirement to Reconstruct (10)


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed. Labels
always require that only values to the right of the "=" sign be
displayed.
0 = None
1 = reconstruct
2 = re-calculate

CL380, Piping Component Type (2500)


1 = [Blank]
2
3
4
5
6
8
18
19
20
21
22
23
24
25
28
29
30
31
33
34
35

=
=
=
=
=
=

Piping
Piping
Piping
Piping
Hose
Tubing
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Primary single line]


[Secondary single line]
[Primary double line]
[Double line]

Gate valve
Extended body gate valve
Conduit gate valve
Blank gate valve
3-way valve
Ball valve
[2-way]
2-way valve
3-way ball valve
Globe valve
[2-way]
Angle globe valve [2-way]
3-way globe valve
Y globe valve
Plug valve
[2-way]
4-way valve
3-way plug valve

Plant Design System (PDS) Reference Data Manager (PD_Data)

479

Appendix: Codelists
36
39
43
47
49
50
51
54
55
56
57
58
59
60
67
68
70
71
73
74
75
79
86
89
90
93
97
98
99
117
119
120
122
124
126
127
128
129
130
131
132
133
135
137
138
139
140
141
142
143
144
148
151

480

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

4-way plug valve


Needle valve
Butterfly valve
Diaphragm valve
Knife gate valve
Slide valve
[2-way]
3-way slide valve
Angle valve
Check valve
Wafer check valve
Angle check valve
Stop check valve
Angle stop check valve
Y stop check valve
Backflow preventer
Automatic recirculation valve
Angle blowdown valve
Y blowdown valve
Pinch valve
Float valve
Foot valve
Tank drain valve
Deluge valve
Hose valve
Angle hose valve
Vent/drain valve
Instrument root valve
3-way instrument root valve
4-way instrument root valve
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Flange
Reducing flange
Expander flange
Orifice flange
Blind flange
Open spectacle blank
Closed spectacle blank
Blank disc
Blind spacer
Tapered spacer
Open spacer
End
Head
Plug
Cap
Diameter change
Concentric diameter change
Eccentric diameter change
Coupling/connector
Half coupling
Concentric reducer
Eccentric reducer
Reducing coupling
Concentric swage

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
152
155
156
157
159
160
162
163
165
167
169
171
172
173
175
176
177
179
181
182
184
189
191
192
193
195
196
198
200
202
204
206
207
209
210
216
218
220
222
223
224
229
231
233
237
239
240
242
243
246
249
251
253
260

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Eccentric swage
Union
Orifice union
Dielectric union
Hose connection
Bushing
Reducing insert
Pipe bend
5.625 deg elbow
11.25 deg elbow
22.5 deg elbow
<45 deg direction change
45 deg direction change
45 deg elbow
45 deg LR elbow
45 deg long tangent elbow
45 deg 3D elbow
45 deg union elbow
45 deg street elbow
45 deg short elbow
45 deg long elbow
60 deg elbow
45-90 deg direction change
90 deg direction change
90 deg elbow
90 deg SR elbow
90 deg LR elbow
90 deg LR long tangent elbow
90 deg reducing elbow
90 deg 3D elbow
90 deg union elbow
90 deg street elbow
90 deg reducing street elbow
90 deg short elbow
90 deg long elbow
180 deg return
180 deg SR return
180 deg LR return
180 deg close return
180 deg medium return
180 deg open return
Miter
45 deg miter
90 deg miter
Tee
Reducing branch tee
Reducing run and branch tee
On-run union tee
On-branch union tee
Street tee
Reducing instrument tee
Drip ring tee
Basin tee
True Y

Plant Design System (PDS) Reference Data Manager (PD_Data)

481

Appendix: Codelists

482

262
264
265
267
268
269
270
275
277
278
279
285
287
288
289
290
291
292
293
294
295
297
299
303
304
310
312
313

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Lateral
Reducing branch lateral
Reducing run and branch lateral
90 deg short Y-branch
90 deg reducing short Y-branch
90 deg long Y-branch
90 deg reducing long Y-branch
Cross
Reducing branches cross
Reducing run and branches cross
Basin cross
Saddle
Sweepolet
Weldolet
Sockolet
Thredolet
Nippolet
Elbolet
Latrolet
Endolet
Reinforcing pad
Reinforcing weld
Buttweld
Branch nipple
In-line nipple
Gasket
Stud
Nut

315
316
317
318
319
320
324
325
327
338
339
340
344
345
346
352
353
354
374
380

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Fire monitor
Elevated fire monitor
Remotely operated fire monitor
Foam monitor
Elevated foam monitor
Remotely operated foam monitor
Fire hydrant
[2-way]
Fire hydrant w/monitor nozzle [2-way]
3-way fire hydrant
Hose reel
Hose rack station
Foam chamber
Wet sprinkler
Pre-action sprinkler
Spray sprinkler
Eye wash
Safety shower
Safety shower and eye wash
Siamese
[2-way]
90 deg siamese
[2-way]

513
515
516
517

=
=
=
=

Flame arrestor
Hammer arrestor
Vent silencer
In-line silencer

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
518
519
521
523
524
525
527
529
533
535
540
542
544
546
548
552
556
557
559
561
563
564
565
567
569
571
576
582
583
584
586
588
590

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Vent
Exhaust head
Breather vent
Free vent w/o screen
Free vent w/screen
Motor operated valve
Mixing T
Spray nozzle
Removable spool
Swing elbow
Expansion joint
Hinged expansion joint
Swivel joint
Mechanical coupling
Flexible hose
Sample cooler
Strainer/filter
Single basket strainer
Duplex basket strainer
T strainer
Y strainer
Temporary strainer
Basket strainer
Cone strainer
Flat plate strainer
Sump strainer
Filter
Steam trap
Float steam trap
Inverted bucket steam trap
Thermostatic steam trap
Thermodynamic steam trap
Impulse steam trap

611 = Generic component


613 = Pip seg heat tracing brk/comp 2
747
748
749
750
823
824
825
833
873
874
875
876
877
878
879
880

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Air utility station


Nitrogen utility station
Water utility station
Steam utility station
Vent/drain detail 1
Vent/drain detail 2
Vent/drain detail 3
Vent/drain detail H
Connection detail 1
Connection detail 2
Connection detail 3
Connection detail 4
Connection detail 5
Connection detail 6
Connection detail 7
Connection detail 8

Plant Design System (PDS) Reference Data Manager (PD_Data)

483

Appendix: Codelists
909
911
913
923
927

=
=
=
=
=

Anchor
1-way support
2-way support
Spring support
Damping support

1008 = Tie-in marker


1018
1019
1020
1038
1039
1040
1041
1042
1043
1044
1045
1047
1049
1053
1068
1069
1070
1071
1072
1073
1074
1075
1079
1083

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Utility connector
Drain connector
Utility station connector
TRM off-dwg piping connector
TLM off-dwg piping connector
TTM off-dwg piping connector
TBM off-dwg piping connector
FRM off-dwg piping connector
FLM off-dwg piping connector
FTM off-dwg piping connector
FBM off-dwg piping connector
Utility off-dwg pip connector
To off-vol piping connector
From off-vol piping connector
TRM off-unit piping connector
TLM off-unit piping connector
TTM off-unit piping connector
TBM off-unit piping connector
FRM off-unit piping connector
FLM off-unit piping connector
FTM off-unit piping connector
FBM off-unit piping connector
To off-site piping connector
From off-site piping connector

1108 = Piping node marker


1117 = Terminator piping connector
Entries above 1500 are reserved for DIN components.
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513

484

=
=
=
=
=
=
=
=
=
=
=
=
=
=

Valve generic
Angle plug valve
Non-return valve
Check valve
Valve with continuous action
4-way globe valve
4-way valve,generic
Steam throttling angle valve
Steam throttling 3-way globe valve
Butterfly valve with continuous action
[Blank]
[Blank]
Globe valve with continuous action
Gate valve with continuous action

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1514
1515
1516
1517

=
=
=
=

Plug valve with continuous action


Angle globe valve with continuous action
Free wheel check valve
Safety check valve

1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530

=
=
=
=
=
=
=
=
=
=
=
=
=

Fire safety butterfly valve


Aeration and deaeration armature
Angle ball valve
4-way ball valve
Taper plug valve
Taper angle plug valve
3-way taper plug valve
4-way taper plug valve
Flat seal bottom
Blank disk
Flange connection
Screwed connection
Angle diaphragm valve

1533
1534
1535
1536
1537
1538
1539
1540
1542
1543
1544
1545
1546
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Safety valve
Safety valve regulated with spring
Safety valve regulated with weight
Angle safety valve
Angle safety valve regulated with spring
Rupture disk
Aeration with screw cap
Inspection glass
Aeration with plug
Flanged aeration
90 deg aeration
180 deg aeration
Tapered filter
Discharge valve with blind flange
Discharge valve
Discharge with blind flanged gate valve
Discharge with gate valve
Bellow expansion joint
Lyra expansion joint
90 degree elbow for JP
T connection for JP
Flange between JP
Valve for connecting JP media
Blindflange JP
Skewed connection JP
Y connection JP
flanged connection segment/comp type 1
flanged connection segment/comp type 2
flanged connection segment/comp type 3
flanged connection segment/comp type 4
Flange from JP to normal pipe
Valve for JP media supply
Flange connection for JP
Bypass for JP media
Flange for bypassing JP

Plant Design System (PDS) Reference Data Manager (PD_Data)

485

Appendix: Codelists
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1587
1588
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Syphon
Ball linkage
Mixing component
Flow straightener
[Blank]
Spring clip
Fire extinguishing equipment powder
Fire extinguishing equipment halogen
Fire extinguishing equipment carbonic acid
Fire extinguishing equipment foam
Fire extinguishing equipment floor connection
Fire extinguishing equipment overhead conn.
Fire extinguishing connector
Fire extinguishing water supply
Fire brigade accessory
Hydrant ground floor
Hydrant overhead
Wall hydrant
Sprinkler equipment
Flooding spray equipment
Spraying equipment
Refrigerating unit
Globe valve with open function
Angle valve with open function
Clamp joint
Taper pipe thread
[Blank]
Socket joint
Taper pipe joint
Cool box
Ball float valve
Ball check valve
Flanged joint

CL390, Action (40)


1 = [Blank]

486

2 = NO
3 = NC
5 = CSO
6 = CSC
10 = LO
11 = LC

[Normally open]
[Normally closed]
[Car seal open]
[Car seal closed]
[Locked open]
[Locked closed]

15
16
18
19
20
24

[Fail
[Fail
[Fail
[Fail
[Fail
[Fail

=
=
=
=
=
=

FO
FC
FL
FLO
FLC
FI

open]
closed]
locked]
locked open]
locked closed]
indeterminate]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
30
31
34
35

=
=
=
=

EO
EC
DEO
DEC

[Energize to
[Energize to
[De-energize
[De-energize

open]
close]
to open]
to close]

CL400, Option (999)


NOTE: In editing this codelist set, do not change the meaning of
the indicated codelist ranges. The number of codelist numbers used
in this codelist set must not exceed 5000.
1 = [Blank]
2 = Bypass PMC
Use to bypass PMC access
Types Options, 11-19
11 = Type 1
12 = Type 2
13 = Type 3
14 = Type 4
15 = Type 5
16 = Type 6
17 = Type 7
18 = Type 8
19 = Type 9
Valve Type Options, 21-60
21 = Red port
24 = Full port
27 = Tight SO
30 = Dbl disc
32 = Y pattern
33 = Wafer
34 = Lug
36 = Single flange
38 = 1/8" hole
39 = Non lube
40 = 3/16" hole
41 = 1/4" hole
42 = Lube
43 = Quick close
44 = Quick open
45 = Al chk
46 = Excess flow
48 = Limit stop
49 = Hor chk
50 = Vert chk
56 = Tap lcn G
57 = Tap lcns G & H
58 = Tap lcns G & I
59 = Tap lcns G & J
60 = Tap lcns G & K

[Reduced port valve]


[Full port valve]
[Tight shutoff valve]
[Double disc valve]
[Y pattern valve]
[Wafer valve]
[Lug pattern]
[Single flange valve]
[1/8" diam hole in flapper]
[Non-lubricated valve]
[3/16" diam hole in flapper]
[1/4" diam hole in flapper]
[Lubricated valve]
[Quick closing valve]
[Quick opening valve]
[Alarm check valve]
[Excess flow check valve]
[Limit stop valve]
[Horizontal check valve]
[Vertical check valve]
[Tap at location G]
[Tap at locations G & H]
[Tap at locations G & I]
[Tap at locations G & J]
[Tap at locations G & K]

Plant Design System (PDS) Reference Data Manager (PD_Data)

487

Appendix: Codelists
Valve Operator Options, 61-100
61 = HW op
[Handwheel]
64 = WR op
[Wrench operator]
67 = LV op
[Lever operator]
70 = T op
[T-handle operator]
73 = GTM op
[Gear operator, top mounted handwheel]
76 = GSM op
[Gear operator, side mounted handwheel]
79 = EM op
[Electric motor operator]
82 = ESHW op
[Extended stem and handwheel]
88 = ESGTM op
[Extended stem and gear operator, top mounted
handwheel
91 = EXGSM op
[Extended stem and gear operator, side mounted
handwheel
100 = Post ind
[Post indicator]
Bend Radius Options, 121-140
121 = 1D bend
[1D pipe bend]
124 = 1.5D bend
[1.5D pipe bend]
127 = 3D bend
[3D pipe bend]
130 = 4D bend
[4D pipe bend]
133 = 5D bend
[5D pipe bend]
134 = 6D bend
[6D pipe bend]
136 = 10D bend
[10D pipe bend]
Head Type Options, 141-150
141 = Hemi hd
143 = Ellip hd
145 = 2:1 hd

[Hemispherical head]
[Ellipsoidal head]
[2:1 elliptical head]

Miter
151 =
152 =
153 =
154 =

[1-cut miter]
[2-cuts miter]
[3-cuts miter]
[4-cuts miter]

Options, 151-160
1 cut
2 cuts
3 cuts
4 cuts

Miscellaneous Options, 161-170


161 = Housing
[Housing]
163 = After vlv
[After isolating valve]
165 = Match branch nipple [Match branch nipple]
167 = Straight ends
[Straight ends]
168 = Hor
[Horizontal]
169 = Vert
[Vertical]
Flange Type Options, 171-200
171 = WN
[Weld neck flange]
173 = LWN
[Long weld neck flange]
175 = SO
[Slip-on flange]
177 = LJ
[Lap joint flange]
179 = PL
[Plate flange]
181 = SS-SO
[Short-stub-end, slip-on flange]
183 = SS-LJ
[Short-stub-end, lap joint flange]
185 = SS-PL
[Short-stub-end, plate flange]
187 = LS-SO
[Long-stub-end, slip-on flange]

488

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
189
191
193
195
196
197

=
=
=
=
=
=

LS-LP
Filler
Socket
SW
SW Red
Thd

[Long-stub-end, lap joint flange]


[Filler flange]
[Socket flange]
[Socketwelded flange]
[Socketwelded reducing flange]
[Threaded flange]

Bolted End Options, 201-400


202 = FE
[Flanged end]
211 = FFFE
[Flat-face flanged end]
216 = FFFEWG
[Flat-face flanged end w/ integral gasket]
221 = RFFE
[Raised-face flanged end]
226 = RFFEWG
[Raised-face flanged end w/ integral gasket]
231 = RJFE
[RTJ-face flanged end]
241 = STFE
[Small-tongue-face flanged end]
242 = LTFE
[Large-tongue-face flanged end]
243 = SMFE
[Small-male-face flanged end]
244 = LMFE
[Large-male-face flanged end]
251 = SGFE
[Small-groove-face flanged end]
252 = LGFE
[Large-groove-face flanged end]
253 = SFFE
[Small-female-face flanged end]
254 = LFFE
[Large-female-face flanged end]
261 = FFLFE
[Flat-face lap-flanged end]
271 = RFLFE
[Raised-face lap-flanged end]
281 = RJLFE
[RTJ-face lap-flanged end]
291 = STLFE
[Small-tongue-face lap-flanged end]
292 = LTLFE
[Large-tongue-face lap-flanged end]
293 = SMLFE
[Small-male-face lap-flanged end]
294 = LMLFE
[Large-male-face lap-flanged end]
301 = SGLFE
[Small-groove-face lap-flanged end]
302 = LGLFE
[Large-groove-face lap-flanged end]
303 = SFLFE
[Small-female-face lap-flanged end]
304 = LFLFE
[Large-female-face lap-flanged end]
311 = FFTBE
[Flat-face thru-bolted end]
316 = FFTBEWG
[Flat-face thru-bolted end w/ integral
gasket]
321 = RFTBE
[Raised-face thru-bolted end]
326 = RFTBEWG
[Raised-face thru-bolted end w/ integral
gasket]
331 = RJTBE
[RTJ-face thru-bolted end]
346 = MRJTBEWG
[Male RTJ-face thru-bolted end w/ integral
gasket]
351 = FFTBCSE
[Flat-face thru-bolted-w/-cap-screws end]
356 = FFTBCSEWG
[Flat-face thru-bolted-w/-cap-screws end w/
integra
361 = RFTBCSE
[Raised-face thru-bolted-w/-cap-screws end]
366 = RFTBCSEWG
[Raised-face thru-bolted-w/-cap-screws end
w/ integ
371 = RJTBCSE
[RTJ-face thru-bolted-w/-cap-screws end]
381 = FFFTBE
[Flat-full-face thru-bolted end]
386 = FFFTBEWG
[Flat-full-face thru-bolted end w/ integral
gasket]
391 = MJE
[Mechanical joint end]

Plant Design System (PDS) Reference Data Manager (PD_Data)

489

Appendix: Codelists
Male End Options, 401-500
401 = BE
402 = OLET
411 = TBE
421 = MFE
431 = MTE
441 = MGE
451 = MQCE
455 = MCE
461 = MFRE
471 = MHE
481 = SPE
491 = PE
493 = 3"FFPE
495 = 6"FFPE

[Beveled end]
[Olet beveled end]
[Tapered and beveled end]
[Male flared end]
[Male threaded end]
[Male grooved end]
[Male quick connect end]
[Male clamp end]
[Male ferrule end]
[Male hose end]
[Spigot end]
[Plain end] [391-399]
[Plain end, 3" field fit]
[Plain end, 6" field fit]

Female End Options, 501-696


501 = SE
521 = SWE
541 = FTE
561 = FGE
581 = FQCE
601 = FFRE
621 = FHE
641 = BLE
642 = MJBE
691 = HCE

[Socket end]
[Socketwelded end]
[Female threaded end]
[Female grooved end]
[Female quick connect end]
[Female ferrule end]
[Female hose end]
[Push-on bell end]
[Mechanical joint bell end]
[Circular hole end]

User Defined Null End Options, (697-697)


697 = NE
[Null end]
User Defined End Options, 699-699
699 = UD
[User defined]
Mixed
701 =
702 =
703 =
705 =
706 =
707 =
708 =
709 =
710 =
711 =
712 =
713 =
714 =
715 =
716 =
717 =

End Options, 701-717


FE x MJE
FE x BE
FE x PE
BE x MTE
BE x PE
BE x SWE
BE x FTE
OLET x FTE
MTE x PE
PE x MTE
PE x SWE
PE x FTE
SWE x FTE
OLET x SWE
MTE x FTE
FE x FTE

[Flanged end by mechanical joint end]


[Flanged end by beveled end]
[Flanged end by plain end]
[Beveled end by male threaded end]
[Beveled end by plain end]
[Beveled end by socketwelded end]
[Beveled end by female threaded end]
[Olet beveled end by female threaded end]
[Male threaded end by plain end]
[Plain end by male threaded end]
[Plain end by socketwelded end]
[Plain end by female threaded end]
[Socketwelded end by female threaded end]
[Olet beveled end by socketwelded end]
[Male threaded end by female threaded end]
[Flanged end by female threaded end]

The following options have been modified to include mm in lengths


and add British metric pressure ratings (PN).

490

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
Nipple Options, 718-755
720 = 3.0"(75mm) BE
721 = 3.0"(75mm) MTE
722 = 3.0"(75mm) PE
723 = 3.0"(75mm) BE x MTE
724 = 3.0"(75mm) BE x PE
725 = 3.0"(75mm) MTE x PE
726 = 4.0"(100mm) BE
727 = 4.0"(100mm) MTE
728 = 4.0"(100mm) PE
729 = 4.0"(100mm) BE x MTE
730 = 4.0"(100mm) BE x PE
731 = 4.0"(100mm) MTE x PE
732 = 5.0"(125mm) BE
733 = 5.0"(125mm) MTE
734 = 5.0"(125mm) PE
735 = 5.0"(125mm) BE x MTE
736 = 5.0"(125mm) BE x PE
737 = 5.0"(125mm) MTE x PE
738 = 6.0"(150mm) BE
739 = 6.0"(150mm) MTE
740 = 6.0"(150mm) PE
741 = 6.0"(150mm) BE x MTE
742 = 6.0"(150mm) BE x PE
743 = 6.0"(150mm) MTE x PE
744 = 7.0"(175mm) BE
745 = 7.0"(175mm) MTE
746 = 7.0"(175mm) PE
747 = 7.0"(175mm) BE x MTE
748 = 7.0"(175mm) BE x PE
749 = 7.0"(175mm) MTE x PE
750 = 8.0"(200mm) PE
751 = 9.0"(225mm) PE
752 = 1O.0"(250mm) PE
753 = 11.0"(275mm) PE
754 = 12.0"(300mm) PE
755 = HEX [Hexagon]

[3.0" long, BE]


[3.0" long, MTE]
[3.0" long, PE]
[3.0" long, BE x MTE]
[3.0" long, BE x PE]
[3.0" long, MTE x PE]
[4.0" long, BE]
[4.0" long, MTE]
[4.0" long, PE]
[4.0" long, BE x MTE]
[4.0" long, BE x PE]
[4.0" long, MTE x PE]
[5.0" long, BE]
[5.0" long, MTE]
[5.0" long, PE]
[5.0" long, BE x MTE]
[5.0" long, BE x PE]
[5.0" long, MTE x PE]
[6.0" long, BE]
[6.0" long, MTE]
[6.0" long, PE]
[6.0" long, BE x MTE]
[6.0" long, BE x PE]
[6.0" long, MTE x PE]
[7.0" long, BE]
[7.0" long, MTE]
[7.0" long, PE]
[7.0" long, BE x MTE]
[7.0" long, BE x PE]
[7.0" long, MTE x PE]
[8.0" long, PE]
[9.0" long, PE]
[10.0" long, PE]
[11.0" long, PE]
[12.0" long, PE]

Rating Options, 756-849


756 = CL25
757 = PN2.5
758 = CL50
759 = CL75
760 = 86#
761 = CL100
762 = CL125
763 = CL150
764 = 175#
765 = PN6
766 = PN10
767 = CL200
768 = PN16
769 = CL250

Plant Design System (PDS) Reference Data Manager (PD_Data)

491

Appendix: Codelists
770
773
774
775
776
777
778
781
782
785
789
790
792
794
795
796
797
801
805
809
813
815
817
821
823
827
831
835
836
838
840

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

275#
CL300
350#
PN25
PN40
CL400
PN64
CL600
PN100
CL800
CL900
PN160
1000#
PN250
PN320
PN400
CL1500
CL2000
CL2500
CL3000
CL4500
CL5000
CL6000
CL9000
CL10000
CL15000
CL20000
CL30000
SCH 40
SCH 80
GRAVHD

Thickness Options, 851-869


851 = 0.0625"(2mm) thck
852 = 0.125"(3mm) thck
853 = 0.1875"(4mm) thck
854 = 0.25"(6mm) thck
855 = 0.3125"(8mm) thck
856 = 0.375"(9mm) thck
857 = 0.4375"(10mm) thck
858 = 0.5"(12mm) thck
859 = 0.5625"(14mm) thck
860 = 0.625"(16mm) thck
861 = 0.6875"(18mm) thck
862 = 0.75"(20mm) thck
863 = 0.8125"(21mm) thck
864 = 0.875"(22mm) thck
865 = 0.9375"(24mm) thck
866 = 1.0"(25mm) thck
End
870
871
873

492

Finish Options, 870-879


= 63 Ra
= 60-100 Ra
= 80-150 Ra

[63 Ra finish]
[60-100 Ra finish]
[80-150 Ra finish]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
875 = 200 Ra
877 = Stock

[200 Ra finish]
[Stock-finish]

Gasket Options, 880-899


880 = F gskt
881 = FFF gskt
882 = C gskt
883 = FDJ gskt
884 = CDJ gskt
885 = R gskt
886 = SW gskt
887 = MSS gskt
894 = SP gskt

[Flat gasket]
[Flat full face gasket]
[Corrugated gasket]
[Flat double jacketed gasket]
[Corrugated double jacketed gasket]
[Ring gasket]
[Spiral-wound gasket]
[MSS-SP-44 gasket]
[Special gasket]

Stud & Nut Options, 900-909


900 = Spec bolt

[Special bolting]

ID Basis Options, 910-910


910 = ID basis

[Dimensions based on inside diameter]

Code Options, 911-989


912 = ANSI-B16.12
[Cast iron drainage fittings]
915 = ANSI-B16.15
[Cast bronze fittings]
922 = ANSI-B16.22
[Copper solder joint pressure fittings]
923 = ANSI-B16.23
[Copper solder joint drainage fittings]
924 = ANSI-B16.24
[Bronze flanges]
929 = ANSI-B16.36
[Orifice flanges]
930 = ANSI-B16.42
[Ductile iron flanges and fittings]
933 = ANSI-B1.20.3
[Dryseal pipe threads]
937 = ANSI-B1.20.7
[Hose coupling screw threads]
945 = ASTM-A74
[Cast iron soil pipe and fittings]
949 = AWWA-C110
[Iron fittings]
950 = AWWA-C115
[Iron pipe and fittings]
955 = AWWA-C151
[Ductile iron pipe]
960 = AWWA-C207 Cl.B & D, ring [Steel slip-on flanges CL86, CL150, CL175]
961 = AWWA-C207 Cl.B & D, hub [Steel slip-on flanges CL86, CL150, CL175]
962 = AWWA-C207 Cl.E, hub
[Steel slip-on flanges CL275]
970 = API-5LE
[Polyethylene fittings]
975 = API-6A
[Wellhead flanges and fittings]
979 = API-605
[API-605 flanges]
980 = MSS-SP-44-NB
[MSS non-blind flanges]
981 = MSS-SP-44-B
[MSS blind flanges]
Vendor Options, 990-999
990 = Tube-Turn
991 = Dow
992 = Aloyco
993 = Yarway
994 = Teledyne Farris 1
995 = R & G Sloane
996 = American DI Pipe
997 = Gladding McBean
998 = Taylor Forge
999 = ITT VALVES

[Vitrified clay S-XS pipe and fittings]

Plant Design System (PDS) Reference Data Manager (PD_Data)

493

Appendix: Codelists
European DIN Standards
1001 = Spacer length 10 mm
1002 = Spacer length 15 mm
1003 = Spacer length 20 mm
1004 = Spacer length 25 mm
1005 = Spacer length 30 mm
1006 = Spacer length 35 mm
1007 = Spacer length 40 mm
1008 = Spacer length 45 mm
1009 = Spacer length 50 mm
1010 = Spacer length 60 mm
1011 = Spacer length 70 mm
1012 = Spacer length 80 mm
1013 = Spacer length 90 mm
1014 = Spacer length 100 mm

CL420, Piping Component Type/Source (25)


NOTE: This codelist defines the type of piping component involved
and the source of the data used in its definition. In editing this
codelist set, do not change the meaning of existing codelist values.
0 = Piping cmdty component from PMC
1 = Piping cmdty component from User
2 = Piping flanged cmdty component from PJS
3 = Piping cmdty component from branch table
4 = Piping specialty component from PJS
5 = Piping specialty component from User - spec data input
6 = Piping specialty component from User - no spec data input
7 = Branch reinforcement from user
8 = Branch reinforcement from branch table

CL425, Piping/Tubing Type (25)


NOTE: In editing this codelist set, do not change the meaning of
existing codelist values.
1 = Piping
2 = Tubing
3 = Hose

CL430, Instrument Component Type/Source (25)


NOTE: This codelist defines the type of instrument component
involved and the source of the data used in its definition. In
editing this codelist set, do not change the meaning of existing
codelist values.

494

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
0 = Instr specialty component from PJS
1 = Instr specialty component from User - spec data input
2 = Instr specialty component from User - no spec data input

CL499, Piping Notes (999)


1 = [Blank]
Notes Applicable to the Piping Materials Class, 2-199
3 = Valve and flange protectors required.
22 = Valves shall be in accordance with NACE MR-01-75.
50 = The Manufacturer shall be consulted for special bolting
requirements where both the design temperature is above 800 degF
and the valve bonnet is insulated.
54 = Unions shall not be used.
56 = Gasket seating surfaces shall have 125 Ra surface finish.
57 = Unions shall not be used. Gasket seating surfaces shall
have 125 Ra surface finish.
58 = Unions shall not be used. Gasket seating surfaces shall
have 125 Ra surface finish. Valves shall be in accordance with
NACE MR-01-75.
60 = All welds shall use compatible rod and shall be PWHT
regardless of thickness and/or joint configuration.
61 = All welds shall use compatible rod and shall be PWHT
regardless of thickness and/or joint configuration unless
specifically approved by Contractor and permitted by
ANSI-B31.3 Code.
62 = Refer to AWWA-C151 for suitable installation types.
63 = Underground pipe and fittings shall be coated and wrapped.
64 = Pipe and fittings shall be cement lined.
79 = Extra thickness has been included.
80 = All components shall be bored to suit thickness of pipe.
Taper bore flanges to a depth of 1.5 inches as required to match
inside diameter of all connecting piping and valves. Welds
shall be ground smooth to match inside diameter of pipe.
82 = Use long radius bends with radius as specified on the P&IDs
for all changes in direction.
83 = Do not allow galvanized or any other zinc bearing material
to come in contact with stainless steel or high nickel
alloys components. This includes supports, nipples, weld
splatter, wire, bolts, paint, or any other type of contact.
Notes
201 =
202 =
203 =
204 =

Applicable to a Piping Component, 200-499


To be used only where specifically required.
Use between blind flange and gasket.
Use for thermowell connections.
Use for hydrostatic vents and drains. Seal (bridge) weld
after testing in accordance with piping job specifications.
205 = Use bends for direction changes.
206 = Use at flanged equipment connections.
207 = Use for hydrostatic vents and drains.

Plant Design System (PDS) Reference Data Manager (PD_Data)

495

Appendix: Codelists
208 = Use threaded plug for vent/drain valve; do not seal weld plug.
209 = To be used only where specifically required and/or between
blind flange and gasket.
210 = Use threaded plug for vent/drain valve; do not seal weld
plug. Vent/drain and instrument root valves with 1 inch nominal
diameter in carbon steel and 9Cr-1Mo materials provide more
than 3/16 inch but less than 1/4 inch CA.
211 = Use of this component under certain pressure/temperature
conditions may provide less than 3/16 inch CA.
214 = Use where full port is required.
220 = Install in the horizontal position only.
221 = Valve shall be in accordance with NACE MR-01-75.
222 = Use 0.75 inch diameter only at orifice flange taps.
223 = Use 0.5 inch diameter only at orifice flange taps.
224 = To be used only where specifically required. Valve sizes
16" and larger require electric motor operators.
253 = Use of unions and threaded fittings shall be limited to a
maximum temperature of 500 degF.
257 = When mating stainless steel flanges to ferritic steel
flanges, use studs corresponding to the ferritic flange.
259 = Double hub fittings are available in 90 degrees and 45
degrees elbows.
260 = Cement lined per AWWA-C205-80. Minimum lining thickness
shall be 0.3125 inch thick. Lining shall be Type II cement per
ASTM-C150 with a minimum 28-day compressive strength of
3000 psi. Lining shall be flush with ends.
276 = Remove internals of valves containing Teflon seats and/or
seals prior to welding or backwelding.
304 = For use in deluge systems.
325 = Do not use over 100 degF.
326 = Do not use over 150 degF.
328 = Do not use over 180 degF.
329 = Do not use over 200 degF.
330 = Do not use over 250 degF.
331 = Do not use over 300 degF.
332 = Do not use over 350 degF.
333 = Do not use over 400 degF.
334 = Do not use over 450 degF.
335 = Do not use over 500 degF.
336 = Do not use over 550 degF.
337 = Do not use over 600 degF.
338 = Do not use over 650 degF.
339 = Do not use over 700 degF.
340 = Do not use over 750 degF.
341 = Do not use over 800 degF.
Notes Applicable to a Piping Specialty, 500-699
Notes Applicable to an Instrument Specialty, 700-899

496

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL530, Accessory/Item Type (125)


NOTE: In editing this codelist set, do not change the meaning of
existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1 = [Blank]
Accessory Type, 2-99
5 = AC =Actuator
10 = A =Alarm
20 = C =Controller
30 = I =Indicator
45 = PO =Positioner
50 = R =Recorder
55 = S =Switch
65 = T =Transmitter
75 = X =Unclassified
80 = Y =Converter
Item Type, 100-125
101 = Equipment nozzle
103 = Piping segment
105 = CV or regulator
107 = Relief device
109 = Other-in-line instrument
111 = Off-line instrument
113 = System function
115 = Instr connector
117 = Function label
121 = Other

CL550, Operator Actuator Type (200)


NOTE: Codelist numbers 2-24 apply to operators for piping
commodity valves whose dimensions are determined from tables whose
names are formed from attributes in the Piping Job Specification.
Codelist numbers 25-40 apply to operators for piping commodity
valves whose dimensions are determined from tables whose names
depend on the commodity codes for the valves. Codelist numbers
41-99 apply to operators and actuators for piping and instrument
specialty valves. Codelist numbers 101-150 should be used for user
defined operators with only primary orientations, such as handwheels
and post indicators. Codelist numbers 151-200 should be used for
user defined operators with both primary orientations and secondary
orientations, such as levers and T-handles.
1 = [Blank]

Plant Design System (PDS) Reference Data Manager (PD_Data)

497

Appendix: Codelists
Operators with Data Derived from Spec Parameters, 2-24
3 = Handwheel
4 = Handwheel if GCP > RCP
5 = Handwheel, inclined
9 = Wrench, short
11 = Wrench, long
17 = Lever
19 = T-handle, short
21 = T-handle, long
Operators with Data Derived from Valve Codes, 25-40
25 = Handwheel, special
27 = Wrench, special
29 = Gear, top mounted handwheel
31 = Gear, top mounted inclined handwheel
33 = Gear, side mounted handwheel
35 = Gear, side mounted inclined handwheel
39 = Lever, quick-action
40 = Post indicator
Actuators, 41-99
41 = Diaphragm
42 = Electro-Pneumatic
43 = Press-balanced diaphragm
45 = Regulator
49 = Single acting cylinder
51 = Double acting cylinder
53 = Pilot operated cylinder
57 = Motor
61 = Digital
65 = Electro-hydraulic
69 = Single solenoid
71 = Single solenoid w/reset
73 = Double solenoid
77 = Pilot
81 = Weight
85 = Manual
89 = Spring
91 = Capacitance sensor
93 = Ball float
95 = Displacement float
97 = Paddle wheel

CL570, Design Standard (200)


1 = [Blank]
10 = ASME-I
11 = ASME-III
12 = ASME-VIII-1
13 = ASME-VIII-2
20 = ASME Fld Mets & AGA Rpt 3

498

[Power Boilers]
[Nuclear]
[Unfired Vessels]
[Unfired Vessels]
[Instruments]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
21
22
23
24
25
28
29
38
50
51

=
=
=
=
=
=
=
=
=
=

ANSI-B31.1
ANSI-B31.2
ANSI-B31.3
ANSI-B31.4
ANSI-B31.5
ANSI-B31.8
ANSI-B31.9
API-2000
AWWA
DIN

[Power]
[Fuel Gas]
[Petroleum]
[Oil Transport]
[Refrigeration]
[Gas Transmission]
[Building Services]
[Tank Venting]
[Water Services]

60 = BS806
61 = BS3351

CL572, Wall Thickness Equation


1 = [Blank]
21 = ANSI B31.1a-1986
23 = ANSI B31.3-1987

CL575, Geometry Standard (31999)


NOTE: The symbol "||" at the end of a description in this document
signifies that the standard has been used in preparing RDB data.
Codelist numbers have been reserved as follows:
o US practices
2-6999
o European practices 1 (DIN)
7000-11999
o European practices 2 (British)
12000-16999
o European practices 3 (Finnish, French, etc.
17000-19999
o International practices 1 (JIS)
20000-24999
o International practices 2 (Australian, etc.)
25000-27999
o Company practices
28000-31999
1 = [Blank]
US Practice Geometry Standards, 2-6999
6 = PDS-P1
[REDE, RWELD, RPAD, BLSPC_>24"_API+/- thk varies,
BLSPO_>24"_API+/- thk varies]
7 = PDS-P2
[BLSPC_>24"__API+/-_0.375"thk,
BLSPO_>24"_API+/-_0.375"th
8 = PDS-P3
[BLSPC_>24"_MSS+/- thk varies, BLSPO_>24"_MSS+/- thk
vari
11 = PDS-I1
[BLSPC_>24"_API+/-_1.5"thk,
BLSPO_>24"_API+/-_1.5"thk]
12 = PDS-I2
[BLPAD_>24"_MSS+/-_0.75"thk,
BLSPA_>24"_MSS+/-_0.75"thk]
13 = PDS-I3
16 = PDS-Op1
17 = PDS-Op2

Plant Design System (PDS) Reference Data Manager (PD_Data)

499

Appendix: Codelists
18 = PDS-Op3
31 = ANSI-B16.1
33 = ANSI-B16.3
34 = ANSI-B16.4
35 = ANSI-B16.5
39 = ANSI-B16.9
40 = ANSI-B16.10
41 = ANSI-B16.11
42 = ANSI-B16.12
44 = ANSI-B16.14
45 = ANSI-B16.15
50 = ANSI-B16.20
51 = ANSI-B16.21
52 = ANSI-B16.22
53 = ANSI-B16.23
54 = ANSI-B16.24
55 = ANSI-B16.25
56 = ANSI-B16.26
58 = ANSI-B16.28
||]
59 = ANSI-B16.29
64 = ANSI-B16.34
66 = ANSI-B16.36
69 = ANSI-B16.39
72 = ANSI-B16.42
73 = ANSI-B16.43
Solvent

[Cast Iron Pipe Flanges and Flanged Fittings ||]


[Malleable Iron Threaded Fittings ||]
[Cast Iron Threaded Fittings ||]
[Pipe Flanges and Flanged Fittings ||]
[Steel Beveled End Fittings ||]
[Dimensions of Ferrous Valves ||]
[Forged Steel Socketwelded and Threaded Fittings ||]
[Cast Iron Threaded Drainage Fittings ||]
[Ferrous Pipe Plugs and Bushings]
[Cast Bronze Threaded Fittings ||]
[RTJ Gaskets and Grooves ||]
[Flat Gaskets for Pipe Flanges ||]
[Wrought Copper Solder Joint Pressure Fittings ||]
[Cast Copper Solder Joint Drainage Fittings ||]
[Bronze Pipe Flanges and Flanged Fittings ||]
[Beveled End Preparation]
[Cast Copper Alloy Fittings for Flared Copper Tubing]
[Steel Beveled End Short Radius Elbows and Returns
[Wrought Copper Solder Joint Drainage Fittings]
[Valves Flanged and Beveled Ends ||]
[Steel Orifice Flanges ||]
[Malleable Iron Threaded Pipe Unions ||]
[Ductile Iron Pipe Flanges and Flanged Fitting ||]
[Wrought Copper Alloy Solder Joint Fittings for
Drainage Systems]

500

81 = ANSI-B18.2.1
82 = ANSI-B18.2.2
100 = ANSI-B36.10M
109 = ANSI-B36.19M

[Square and Hex Bolts and Screws ||]


[Square and Hex Nuts]
[Welded and Seamless Wrought Steel Pipe ||]
[Stainless Steel Pipe ||]

114 = API-5A
115 = API-5B
119 = API-5L
120 = API-5LE
122 = API-5LP
124 = API-5LS
126 = API-5LU
127 = API-5LX
131 = API-6A
132 = API-6AB
135 = API-6D
Swivels]
141 = API-526
145 = API-590
146 = API-590Z1
147 = API-590Z2
153 = API-593
154 = API-594
155 = API-595

[Casing, Tubing and Drill Pipe]


[Casing, Tubing and Line Pipe Threads]
[Line Pipe ||]
[Polyethylene Line Pipe ||]
[Thermoplastic Line Pipe ||]
[Spiralweld Line Pipe ||]
[Ultra High Test Heat Treated Line Pipe ||]
[High Test Line Pipe]
[Wellhead Equipment]
[30,000 PSI Flanged Wellhead Equipment]
[Pipeline Valves, End Closures, Connectors and
[Flanged Steel Safety Relief Valves]
[Steel Line Blanks ||]
[Steel Line Blanks - with 0.125" CA ||]
[Steel Line Blanks - with 0.25" CA ||]
[Ductile Iron Plug Valves]
[Wafer Check Valves]
[Cast Iron Gate Valves]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
157
159
160
161

=
=
=
=

API-597
API-599
API-600
API-601

[Steel Venturi Gate Valves]


[Steel Plug Valves]
[Steel Gate Valves ||]
[Metallic Gaskets for Raised Face Pipe Flanges and
Flanged Connections ||]

162
163
164
165
166
169

=
=
=
=
=
=

API-602
API-603
API-604
API-605
API-606
API-609

[Compact Steel Gate Valves]


[Class 150 Cast Flanged End Gate Valves]
[Ductile Iron Gate Valves]
[Large Diameter Carbon Steel Flanges ||]
[Compact Carbon Steel Gate Valves]
[Butterfly Valves Lug and Wafer Type]

171 = ASTM-A74
172 = ASTM-C76
Pipe]
173 = ASTM-C700

[Cast Iron Soil Pipe and Fittings]


[Reinforced Concrete Culvert, Storm Drain and Sewer

174 = ASTM-D2464
176 = ASTM-D2466
||]
177 = ASTM-D2467
||]

[Threaded PVC Plastic Pipe Fittings Schedule 80]


[Socket-Type PVC Plastic Pipe Fittings Schedule 40

179
181
184
186

[Cast Iron Pipe]


[Ductile Iron and Gray Iron Fittings 3"-48" ||]
[Ductile Iron and Gray Iron Pipe]
[Ductile Iron Pipe ||]

=
=
=
=

AWWA-C106
AWWA-C110
AWWA-C115
AWWA-C151

[Extra Strength and Standard Strength Clay Pipe and


Perforated Clay Pipe]

[Socket-Type PVC Plastic Pipe Fittings Schedule 80

190= AWWA-C207 Cl.B & D, ring


[Steel slip-on flanges CL86, CL150, CL175 ||]
191= AWWA-C207 Cl.B & D, hub
[Steel slip-on flanges CL86, CL150, CL175 ||]
192= AWWA-C207 Cl.E, hub
[Steel slip-on flanges CL275 ||]
193 =
200 =
204 =
206 =
207 =
208 =
220 =
221 =
Water
222 =
Water
230 =

AWWA-C208
AWWA-C500
AWWA-C504
AWWA-C506
AWWA-C507
AWWA-C508
AWWA-C900
AWWA-C901

[Steel Water Pipe Fittings]


[Gate Valves 3"-48" for Water and Sewage Systems]
[Rubber Seated Butterfly Valves]
[Backflow Prevention Devices-Check Valves]
[Ball Valves]
[Swing Check Valves for Water Works Service 2"-24"]
[PVC Pipe 4"-12" for Water]
[Polyethylene Pipe, Tubing and Fittings 1/2"-3" for

AWWA-C902

[Polybutylene Pipe, Tubing and Fittings 1/2"-3" for

AWWA-C950

[Glass-Fiber Reinforced Pressure Pipe]

235 = PFI-ES-24

[Pipe Bending Tolerances ||]

243 = ISA-S75.03
244 = ISA-S75.04

[Face to Face Dimensions Globe Control Valves]


[Face to Face Dimensions Flangeless Control Valves]

Plant Design System (PDS) Reference Data Manager (PD_Data)

501

Appendix: Codelists
252
253
254
255
268
277
278
282
285
288
289
290
291
293
||]
295
297

=
=
=
=
=
=
=
=
=
=
=
=
=
=

MSS-SP-42
MSS-SP-43
MSS-SP-44
MSS-SP-51
MSS-SP-58
MSS-SP-67
MSS-SP-68
MSS-SP-72
MSS-SP-75
MSS-SP-78
MSS-SP-79
MSS-SP-80
MSS-SP-81
MSS-SP-83

= MSS-SP-88
= MSS-SP-95

[CL150 Valves ||]


[Stainless Steel Buttwelding Fittings]
[Steel Pipe Line Flanges ||]
[CL150LW Cast Flanges and Flanged Fittings]
[Pipe Hangers and Supports]
[Butterfly Valves]
[High Pressure-Offset Seat Butterfly Valves]
[Ball Valves with Flanged or Beveled Ends]
[Wrought Beveled End Fittings]
[Cast Iron Plug Valves]
[Socketwelding Reducing Inserts]
[Bronze Gate, Globe, Angle & Check Valves]
[Flanged, Wafer Knife Gate Valves]
[Carbon Steel Socketwelded and Threaded Pipe Unions
[Diaphragm Valves]
[Swage Nipples and Bull Plugs ||]

298 = NFPA-1963
[Screw Threads and Gaskets for Fire Hose connections]
300 = ASME BPE-97
[Geometry standards that follow apply to specific manufacturers.
If one of these standards is used to define a component, the
following information will be shown in brackets to the right of the
geometry standard:
o For valves: the applicable model codes and vendors designations
o For fittings: the applicable model codes will be shown unless
the vendors designation is required to differentiate between
components requiring a different geometry standard to assign them
to the proper data table.
1000 = Adamson 1
1001 = Adams 1
1025 = Aitken 1
[BLPAD; BLSPA; TDRA; TDRB; TDRBW ||]
1026 = Aitken Z1
[BLPAD; BLSPA - with 0.125" CA ||]
1027 = Aitken Z2
[BLPAD; BLSPA - with 0.25" CA ||]
1050 = Allied Pipe Products 1
1075 = Aldo Colombo 1
1100 = Aloyco 1
[GATR-Fig_114; GATR-Fig_114DB; GATR-Fig_114EB;
GATR-Fig_124;
GATR-Fig_2214A; GLOR-Fig_2310A; GLOR-Fig_2314A; GLOR-Fig_314;
GLOR-Fig_31
GLOR-Fig_314EB; GLOR-Fig_504; CKLR-Fig_554; CKLR-Fig_2554A;
CKSR-Fig_2374
CKSR-Fig_374; TKDR-Fig_751 ||]
1101 = Aloyco 2
[GATR-Fig_2110; GATR-Fig_2114 ||]
1125 = American Darling 1 [H3W1-Fig_B-50-B ||]
1130 = American DI Pipe
[PIPE; L; LRB ||]
1150 = American Valve 1
1175 = Amri 1
1200 = Anaconda 1
1225 = Anderson Greenwood 1
1250 = Anvil 1
1275 = A.O.Smith 1
1300 = Apollo 1

502

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
1325 = Argus 1
1350 = Armstrong 1
S70BC-Fig_2011 ||]
1375 = Asahi/American 1
1400
1425
1450
1475

=
=
=
=

[S51AC-Fig_K1SC; S70AC-Fig_2011;

Babbitt 1
Babcock and Wilcox 1
Badger Meters 1
Bailey Co 1

1500 = Balon 1
1525 = Basic Engineering 1
1550 = Bestobel 1
1560 = Bete 1 [SSP1-Series_N ||]
1575 = Bonney Forge 1
[GAT-Fig_9HLF-10; GATR-Fig_9H-10;
GATR-Fig_9W-10;
GATEXB-Fig_VLL-10; GATEXB-Fig_VOLL-10; GLOR-Fig_HL-30;
GLOR-Fig_9HL-30;
GLOR-Fig_9WL-30; CKLR-Fig_9HL-40; CKLR-Fig_9HL-50; CKLR-Fig_9HL-60;
CKLR-Fig_9WL-40; CKLR-Fig_9WL-50; CKLR-Fig_9WL-60; CKLR-Fig_HL-40;
CKLR-Fig_9HLF-40; CKLRY-Fig_9Y-40; CKLRY-Fig_25Y-40; CAPOT; UN; L;
LRB;
SWOL; WOL; SOL; TOL; NOL; EOLLR; EOLSR; LOL ||]
1576 = Bonney Forge 2 [GATR-Fig_9H-10; GATR-Fig_25W-10; GLOR-Fig_9HL-30;
GLOR-Fig_9WL-30; GLOR-Fig_25W-30; GLOY-Fig_25Y-30; CKLR-Fig_9HL-40;
CKLR-Fig_9HL-50; CKLR-Fig_9HL-60; CKLR-Fig_9WL-40; CKLR-Fig_9WL-50;
CKLR-Fig_9WL-60 ||]
1577 = Bonney Forge 3 [GATF-Fig_H-10; GATF-Fig_W-10; GATR-Fig_HL-10;
GATR-Fig_WL-10; CKLR-Fig_HL-40; CKLR-Fig_WL-40 ||]
1585 = Boots & Coots 1 [MN1-Spectrum_Allpha_6235 ||]
1590 = Bray 1
1600 = Brooks Meters 1
1625 = Cameron 1
1650 = Carbone 1
1675 = Ciba-Geigy 1
1700 = Clark Reliance 1
1725 = Clayton Automatic Valves 1 [CKBP-Model_D; FLO-Series_427-01 ||]
1750 = Clayton Mark 1
1775 = Clow 1
1800 = Cochrane 1
1825 = Condren 1
1850 = Continental Emsco 1
1875 = Cooper Valve 1
1900 = Crane 1 [GATF-Fig_3904U; GATR-Fig_424; GATR-Fig_431UB;
BALR-Fig_9302;
GLOF-Fig_3944U; GLOR-Fig_14 1/2P; GLOR-Fig_70; GLOY-Fig_7189;
NEE-Fig_88;
CKS-Fig_373;CKLF-Fig_3973U; CKSR-Fig_36; CKSR-Fig_137;
FOOT-Fig_394;
FOOT-Fig_395; FLWN; FSO; L; LRB ||]
1925 = Crosby 1
1950 = Daniel 1

Plant Design System (PDS) Reference Data Manager (PD_Data)

503

Appendix: Codelists
1975
2000
2025
2050
2075
2100
2150
2155
2175

=
=
=
=
=
=
=
=
=

Demco 1
Dezurik 1
Dixon 1
Dresser 1
Dover 1
DOW 1 [TRI-Lining_SL; TRI-Lining_PPL, TRI-Lining_KL ||]
Duo Seal 1
Dur-O-Lock 1 [CPL ||]
Durco 1

2200
2225
2250
2275

=
=
=
=

Elkhart 1
Enpro 1
Epsco 1
Everest 1

2300
2325
2350
2375
2400
2425
2450
2475
2500
2525
2550
2575
2600
2625
2650
2660
2675
2700
||]
2715
2725
2750

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Fabri-Valve 1 [KNF-Fig_36 ||]


Fairbanks 1
Fasani 1
Fetterolf 1
Fibercast 1
Fike 1
Fisher 1
Flexitallic 1
Flowline 1
FMC 1
Foxboro 1
Garlok 1
General 1
Geosource 1
Gestra 1
Gladding McBean 1 [REDC; E45; E90; M451; M452; L ||]
Graylock 1
Grinnell 1 [BALR-Fig_3022; CAPOT; UNO; E45U; E90RST; TOUB; TOUR

= Grinnell Fire Prot 1 [DEL-Model_A-4; SSP-Mulsifyre-Projector ||]


= Grove 1
= Gulf 1

2775
2800
2825
2850
2860
2875
2900
2915
2925

=
=
=
=
=
=
=
=
=

Hammond 1
Hancock 1 [BDA-Fig_5505W ||]
Haws 1 [SSEW1-Fig_8309; SSEW1-Fig 8309CRP ||]
Heaton 1
Hex 1
Hindle-Hamer 1
Hitachi 1
Hoke 1
Hydril 1

2950 = Imperial Eastman 1


2975 = Ishida 1
2980 = ITT 1
3000 = Jacoby Tarbox 1
3025 = Jamesbury 1 [BALR-Style_B; BALSP-Type_530S; BAL3W-Style_AM150FD;

504

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
3026
3027
3028
3050
3075
3100

BAL3W-Style_DM150FD ||]
= Jamesbury 2 [BALR-Style_A ||]
= Jamesbury 3 [BALR-Type_2000_Brass ||]
= Jamesbury 4 [BALF-Type_4000; BALR-Type_4000 ||]
= Jenkins 1
= Jerguson 1
= Judd Valve 1

3125
3150
3175
3200
3225
3250
3275
3300

=
=
=
=
=
=
=
=

Kamyr-Neles 1
Kemp 1
Kennedy 1
Keystone 1
Kinka Kikai 1
Kitz 1
KTM 1
Kubota 1

3325
3350
3375
3400
3425

=
=
=
=
=

L & M Valve 1
Ladish 1 [CAPOT; L; LRB ||]
Lamons 1
Lukens 1
Lunkenheimer 1

3445
3450
3475
3500
3525

= Mac-Iron 1
= Magnetrol 1
= Malbranque 1
= Maloney 1
= Mark Controls/Centerline 1 [BFYLP-Series_A; BFYLP-Series_LT;
BYFLP-Series_504 ||]
3550 = Mark Controls/Flowseal 1 [BFYHP-Style_1LB ||]
3575 = Mark Controls/Marpac 1
3600 = Mark Controls/Pacific 1 [GATSP-Fig_21555; GATSP-Fig_55509;
GATSP-Fig_5
GLOSP-Fig_56009; GLOSP-Fig_56015; CKSSP-Fig_58809-5-WE;
CKSSP-Fig_58815-7-WE;
CKST-Fig_160S ||]
3625 = Marlin 1
3650 = Marwin 1
3675 = Masoneilan 1
3700 = Media 1 [BFYLP]
3725 = Milwaukee 1
3750 = Mueller/Muessco Brass 1
3775 = Mueller/Muessco Steam Specialty 1 [S51AC-Fig_761WE;
S51AC-Fig_862BC;
S51AC-Fig_762 ||]
3800
3825
3850
3860
3875
3900
3925

=
=
=
=
=
=
=

Navco 1
Nells 1
Newco 1
Nibco 1
Nicholson 1 [S78AC-Fig_N302L ||]
Nippon-Benkan 1 [BW fittings above 48" ||]
Nupro 1

Plant Design System (PDS) Reference Data Manager (PD_Data)

505

Appendix: Codelists
3950 = OPW 1
3975 = Orbit 1
4000 = Oseco 1
4025
4030
4050
4075
4100
4125
4150
4175
4200
4225
4250
4275
4300
4325

= Pan Korea 1
= Parker CPI 1
= Parks Cramer 1
= Peabody Dore 1
= Penberthy 1
= Penn-AirCheck 1
= Persta 1
= Petrolvalves 1
= Posi-Seal 1 [BFYHP-Model A31; BFYHP-Model A21; BFYHP-Model A11 ||]
= Powhatan 1 [HOS-No_18-217; HOSA-No_18-157; HRST1-No_30-333 ||]
= Powell 1
= Pratt 1 [BFYLP-Model_PIVA & IBV-FM4; Groundhog ||]
= Premafu 1
= Protectoseal 1

4335
4350
4375
4400
4425

=
=
=
=
=

R & G Sloane [BALF-Fig_1081; CAPOT; FS; INSR1]


Resistoflex 1 [PIN-Code_R6000D1 ||]
Ring-O 1
Rockwell 1 [DIA-Type_STD_Unlined ||]
Rockwell/Edwards 1 [GLOA-Fig_849; GLOA-Fig_849Y; GLOYR-Fig_848;
GLOYR-Fig_848Y; GLOYR-Fig_1048; GLOYR-Fig_1048Y; CKLRY-Fig_36178;
CKLRY-Fig_36278; NEE-Fig_4152; CKST-Fig_302; CKST-Fig_302Y;
CKAST-Fig_303
CKAST-Fig_303Y; CKAST-Fig_869; CKAST-Fig_869Y; CKYST-Fig_302;
CKYST-Fig_6
BDY-Fig_1641; ||]
4426 = Rockwell/Edwards 2 [CKLRY-Fig_832Y; GLOY-Fig_36124;
GLOY-Fig_36128;
CKLRY-Fig_1032Y; CKAST-Fig_605Y; CKAST-Fig_607Y; BDA-Fig_1643Y
||]
4427 = Rockwell/Edwards 3 [GLOY-Fig_7514Y ||]
4450 = Rockwell/McCanna 1 [BAL3W-Type_500-3WAY ||]
4475 = Rockwell/Nordstorm 1 [PLUVP-Fig_4169; PLU3W-Fig_3813;
PLU3W-Fig_4812;
PLU3W-Fig_4813; PLU3W-Fig_5115; PLU3W-Fig_5119;
PLU3W-Fig_5215;
PLU3W-Fig_5219; PLU4W-Fig_3823; PLU4W-Fig_4822;
PLU4W-Fig_5125;
PLU4W-Fig_5129 ||]
4500 = R P & C 1
4520 = Sarco 1
4522 = Saunders 1
4525 = Sella 1
4550 = Serck Audco 1
4575 = Serfilco 1
4600 = Shoritsu 1
4625 = Smith 1 [GATF-Fig_888; GATF-Fig_5870; GATR-Fig_800; GATR-Fig_870;
GATR-Fig_1500; GATR-Fig_1570; GATEX-Fig_811 & 812 MPE/THD; GATEX-Fig_876
& 877 MPE/THD; GATEXB-Fig_874 & 875 OLET/THD; GATXBA-Fig_874 & 875 OLET/S

506

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
GATXBB-Fig_874 & 875 OLET/THD; GLOR-Fig_G80; GLOR-Fig_G87;
GLOR-Fig_G150;
GLOR-Fig_G157; CKLR-Fig_B80; CKLR-Fig_C80; CKLR-Fig_C150;
CKLR-Fig_SB80;
CKLR-Fig_SC80 ||]
4626 = Smith 2 [GATEX-Fig_813 & 814 MPE/SW; GATEX-Fig_878 & 879 MPE/SW
||]
4650 = Spraying Systems 1
4675 = Spirax Sarco 1
4700 = Stanco 1
4725 = Standard Fittings 1 [CAPOT; SWGC; SWGE ||]
4750 = Stang Hydronics 1 [M1-Fig BB0309-21 w/shapertip nozzle; ME1-Fig
BB3561
4751 = Stang Hydronics 2 [M1-Fig_BB0309-21 w/fog nozzle; ME1-Fig B22999
||]
4752 = Stang Hydronics 3 [ME1-Fig_BB3561 composite, w/monitor nozzle ||]
4753 = Stang Hydronics 4 [ME1-Fig_BB3377 composite, w/monitor nozzle ||]
4775 = Stockham 1
4800 = Strahman 1
4825 = Swagelok 1
4850 =
4875 =
4900 =
4901 =
4925 =
4950 =
4975 =
5000 =
5025 =
5050 =
5060 =
5075 =
5085 =
5100 =
5125 =
5150 =
L; SA
5175 =
5200 =

Tapco 1
Taylor 1
Taylor Forge 1
Taylor Forge 2, Rev 1957 [L; S-STD WT ||]
Teledyne Farris 1
Texas Bolt 1
Thevignot 1
Titeflex 1
TK 1
TKM 1 [GAT-Fig_100 ||]
Top Line 1
Triangle 1
Tri-Clover 1
Truflo 1
TRW/Mission 1 [||]
Tubeturn 1 [FWN; FEWN; FOWNA; FOWNB; CAPBV; E453D; E90LT; E903D;
Tufline 1
Tyler 1 [CPL; REDC; E45LT; E90LT; L ||]

5225
5250
5275
5300
5325
5350
5375

= Valvotecnic 1
= Vanessa 1
= Velan 1 [S3AC-Fig_N675 ||]
= Victaulic 1
= Viking 1
= Vitas 1
= Vogt 1 [GATR-Series_15373; GLOR-Series_15141; CKLR-Series_15701;
NEE-Series_22461; NEE-Series_SW22461; CAPOT; UN; E90U; E90ST; L ||]

5400
5425
5450
5475

=
=
=
=

Wada 1
Wallworth 1
Watts Regulator 1
Weco 1

Plant Design System (PDS) Reference Data Manager (PD_Data)

507

Appendix: Codelists
5500 = WFI 1
5525 = Winston 1 [S49AC-T-Strainer Type-59 W/flgd cover;
S53AC-Basket-Strain
Fig 51-WIP W/CL150 flgd cover & 3/4" SWE drain||]
5535 = Wirt & Knox 1
5550 = WKM 1
5575 = Worcester 1
5600 = Yarway 1 [CKAR-Fig_5301; CKAR-Fig_5302; BDA-Fig_6909-C;
BDY-Fig_6911-C
TKDR-Fig_8106 ||]
5625 = Yoneki 1
5650 = Zurn 1
o European practices 1 (DIN) 7000-11999
General Specifications
7000 = DIN 2401-1 Pressure, nominal
7001 = DIN 2401-2 Pressure, nominal
7002 = DIN 2402 Diameter,nominal
Pipes
7010 =
7011 =
7012 =
7013 =
7014 =
7015 =
7016 =
7017 =
7018 =
7019 =
7020 =

508

DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN

2448
2458
2440
2441
2442
2445
2460
2462
2463
2391
2393

;Steel pipes, seamless


;Steel pipes, welded
;Threaded pipes, medium weight
;Threaded pipes, heavy weight
;Threaded pipes, spec. qualty
;Seamless steel pipes,dyn. load
;Steel pipes for water
;Seamless ferritic steel pipes
;Seamless austenitic steel pipes
;Seamless precision steel tubes
;Welded precision steel tubes

7025 = DIN 2848


7026 = DIN 2873

;Flanged lined pipes


;Flanged lined enamelled pipes

7030 = DIN 2462


7031 = DIN 2463

;Seamless stainless steel tubes


;Welded austenitic steel pipes and tubes

7040 = DIN 8062


7041 = DIN 8077

;Pipes of unplasticized polyvinyl chlor.


;Polypropylen (PP) pipes

Flanges
7100 = DIN
7101 = DIN
7102 = DIN
7103 = DIN
7104 = DIN
7105 = DIN
7106 = DIN
7107 = DIN
7108 = DIN
7109 = DIN

;Cast
;Cast
;Cast
;Cast
;Cast
;Cast
;Cast
;Cast
;Cast
;Cast

2530
2531
2532
2533
2534
2535
2543
2544
2545
2546

iron flanges, PN 2,5


iron flanges, PN 6
iron flanges, PN 10
iron flanges, PN 16
iron flanges, PN 25
iron flanges, PN 40
steel flanges, PN 16
steel flanges, PN 25
steel flanges, PN 40
steel flanges, PN 64

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
7110
7111
7112
7113
7114
7115
7116
7117
7118
7119
7120
7121
7122
7123
7124
7125
7126
7127
7128
7129
7130
7131
7132
7133
7134
7135
7136
7137
7138
7139
7140
7141
7142
7143
7144
7145
7146
7147
7148
7149
7150
7160
7161
7162

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN

2547
2548
2549
2550
2551
2558
2561
2565
2566
2567
2568
2569
2630
2631
2632
2633
2634
2635
2636
2637
2638
2628
2629
2627
2673
2667
2668
2669
2573
2576
2641
2642
2652
2653
2655
2656
2501
2512
2512
2513
2514
2527
2848
2873

;Cast steel flanges, PN 100


;Cast steel flanges, PN 160
;Cast steel flanges, PN 250
;Cast steel flanges, PN 320
;Cast steel flanges, PN 400
;Plain face oval screwed flange PN 6
;Oval screwed flange w/ socket PN 10,16
;Screwed flange PN 6 rund
;Screwed flange PN 10,16
;Screwed flange PN 25,40
;Screwed flange PN 64
;Screwed flange PN 100
;Welding neck flange PN 1
;Welding neck flange PN 6
;Welding neck flange PN 10
;Welding neck flange PN 16
;Welding neck flange PN 25
;Welding neck flange PN 40
;Welding neck flange PN 64
;Welding neck flange PN 100
;Welding neck flange PN 160
;Welding neck flange PN 250
;Welding neck flange PN 320
;Welding neck flange PN 400
;Loose flange w/ wldg neck PN 10
;Loose flange w/ wldg neck PN 160
;Loose flange w/ wldg neck PN 250
;Loose flange w/ wldg neck PN 320
;Flange, soldering or wldg PN 6
;Flange, soldering or wldg PN 10
;Flange, lapped, plain collar PN 6
;Slip-on flange, upturned wldg PN 10
;Flange, lapped, plain collar PN 6
;Flange, lapped, plain collar PN 10
;Flange, lapped, plain collar PN 25
;Flange, lapped, plain collar PN 40
;Flanges, Dimensions
;Flanges, tongue & groove
;Rings
;Flanges, projection & recess
;Projection w/ groove & recess
;Flange, blind PN 6,10,16,25,40,64,100
;Reducing flanges, lined
;Reducing and blind flanges, enamelled

Elbows
7200 =
7201 =
7202 =
7203 =
7204 =
7205 =
7206 =

DIN
DIN
DIN
DIN
DIN
DIN
DIN

2605
2606
2916
2983
2987
2987
2950

;Tube bends f. butt wldg


;Tube bends, steel 5d
;Bending radii, seaml.& wld pipes
;Threaded steel pipe fittings, bends
;Threaded steel pipe fittings, elbows
;Threaded steel pipe fittings, elbows, reduced
;Malleable cast iron fittings, elbows

Plant Design System (PDS) Reference Data Manager (PD_Data)

509

Appendix: Codelists
7210
7211
7212
7213
7214
7215
7216
7217
7218
7219

=
=
=
=
=
=
=
=
=
=

DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN

2605-1
2605-1
2605-1
2605-1
2605-1
2605-2
2605-2
2605-2
2605-2
2605-2

7230 = DIN 2848


7231 = DIN 2873

bend
bend
bend
bend
bend
bend
bend
bend
bend
bend

radius
radius
radius
radius
radius
radius
radius
radius
radius
radius

1d, standard 12.85


1.5d, standard 12.85
2.5d, standard 12.85
5d, standard 12.85
10d, standard 12.85
1d, standard 12.85
1.5d, standard 12.85
2.5d, standard 12.85
5d, standard 12.85
10d, standard 12.85

;Flanged lined steel fittings, Bends


;Flanged steel fittings enamelled, Bends

7240 = DIN 16962


7241 = DIN 16962
7242 = DIN 16962

;Polypropylen (PP) components, Pipe bends B1,B2


;Polypropylen (PP) components,Elb. W1,W2,part 6
;Polypropylen (PP) components,Elb.W3,W4,part 10

Reducers
7300 = DIN 2616
7301 = DIN 2990
7302 = DIN 2988
7303 = DIN 2950
7304 = DIN 2950

;Steel fittings, reducers


;Threaded steel pipe fittings, Bushings
;Threaded steel pipe fittings, Reducing sockets
;Malleable cast iron fittings, Reducing sockets
; - " - , male and female connections, Bushings

7310 = DIN 2848


7311 = DIN 2873

;Flanged lined steel fittings, Reducers


;Flanged steel fittings enamelled, Reducers

7320
7321
9
7322
7323

= DIN 16962
= DIN 16962

;Polypropylen (PP) components, Red. R1, part 9


;Polypropylen (PP) components, Red. NRGI, part

= DIN 16962
= DIN 16962

;Polypropylen (PP) components, Red. R2, part 10


;Polypropylen (PP) components, Red. R3, part 11

Branches
7400 = DIN
7401 = DIN
7402 = DIN
7403 = DIN
7404 = DIN
7405 = DIN
7406 = DIN

2615
2618
2618
2619
2987
2987
2950

;Butt wldg steel fittings;T


;Welding saddles, short
;Welding saddles, long
;Bends for welding
;Threaded steel fittings;cross;T
;Threaded steel fittings;cross;T;redcd
;Malleable cast iron fittings, Tees, Crosses

7410 = DIN 2848


7411 = DIN 2873

;Flanged lined steel fittings, T


;Flanged steel fittings enamelled, T

7420
2
7421
7422
7423

= DIN 16962

;Polypropylen (PP) components, Tee, T1,T5 part

= DIN 16962
= DIN 16962
= DIN 16962

;Polypropylen (PP) components, Tee, T2, part 7


;Polypropylen (PP) components, Tee, T2G, part 7
;Polypropylen (PP) components, Tee, T3, part 10

Caps
7500 = DIN 2617

510

;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,
;Elbows,

;Butt wldg steel fittings, Caps

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
7501 = DIN 2991
7502 = DIN 2950

;Threaded steel fittings, Caps


;Malleable cast iron fittings, Caps

7510 = DIN 16962


7511 = DIN 16962

;Polypropylen (PP) components, Cap K1, part 8


;Polypropylen (PP) components, Cap K2, part 10

Other fittings
7600 = DIN 2981
7601 = DIN 2982
7602 = DIN 2982
7603 = DIN 2986
7604 = DIN 2990
7605 = DIN 2991
7606 = DIN 2993

;Threaded steel fittings with long screw thread


;Threaded steel fittings, Parallel Nipples
;Threaded steel fittings, Taper Nipples
;Threaded steel fittings, Sockets
;Threaded steel fittings, Hexagon Nipples
;Threaded steel fittings, Plain plugs
;Threaded steel fittings, Pipe unions

7610 = DIN 2950

;Malleable cast iron fittings, Sockets, Unions,


;Nipples, Plugs etc.

7620 = DIN 16962 ;Polypropylen (PP) components, Soc. M1,MGI, p. 8


7630 = DIN 2848
7631 = DIN 2873

;Flanged lined steel fittings, spacers


;Flanged lined steel fittings enamelled, spacers

Bolts and Nuts


8000 = DIN 934
8001 = DIN 931
Gaskets
8100 = DIN
8101 = DIN
8102 = DIN
8103 = DIN
8104 = DIN
8105 = DIN
8106 = DIN
8107 = DIN

2690
2691
2692
2693
2695
2696
2697
2698

Valves
9000 =
9010 =
9020 =
9030 =
9040 =
9050 =

conform DIN 3202


3202-F
; Teil
3202-S
; Teil
3202-K
; Teil
3202-M
; Teil
3202-F
; Teil

Non
DIN
DIN
DIN
DIN
DIN

;Gasket for plain face C


;Gasket for tongue & groove
;Gasket for recessed faces
;Rings for grooved faces
;Diaphragm
;Lenticular gaskets
;Grooved O- rings
;Corrugated steel sheet

1
2
3
4
5

Dummy standard
9999 = Dummy DIN Std ; Used for engineered items and instruments
British Standards geometry standards 12000-16999
sub ranges (provisional) :12000-12099 pipes
12100-12199 flanges

Plant Design System (PDS) Reference Data Manager (PD_Data)

511

Appendix: Codelists
12200-12599
12600-12999
13000-13199
13200-13499
PIPES
12000
12001
12002
12003
12004

=
=
=
=
=

fittings
valves
bolts
gaskets

BS3600
BS3600
BS3600
BS3600
BS3600

table
table
table
table
table

1
2
3
4
5

carbon and low alloy steel tubes


austenitic stainless steel tubes
high alloy ferritic steel tubes
cs tubes for compression fitting - tbi
ss tubes for compression fitting - tbi

12010 = BS1387 tables 3,4 and 5 light,medium and heavy


12015 = BS1600 part 2 steel pipe for petroleum industry
FLANGES
12100 = BS4504 p1 steel flanges for pipe,valves and fittings
12101 = BS4504 p1 iron flanges for pipe,valves and fittings - tbi
12110 = BS1560 p2 steel pipe flanges Metric dimensions
FITTINGS
12200 = BS1740
12210 = BS1965
12220 = BS3799
12221 = BS3799
12230 = BS1640

part 1 screwed wrought steel pipe fittings


part 1 butt welding pipe fittings - CS
steel pipe fittings screwed and socket welding (mm)
steel pipe fittings screwed and socket welding (in)
part 3/4 steel butt-welding pipe fittings

VALVES
12600
12620
12625
12630
12635
12640
12645
12646
12650
12651
12655
12656
12660
12661
12665
12666
12670
12671

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

BS2080 flanged
BS5150
BS5151
BS5152
BS5153
BS5154
BS5155
BS5155 and app
BS5156
BS5156 and app
BS5157
BS5157 and app
BS5158
BS5158 and app
BS5159
BS5159 and app
BS5160
BS5160 and app

and butt-welded steel valves

A
A
A
A
A
A

gaskets
13001 = BS4865:part 1 - non-metallic for BS4504 flanges

512

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
13002 = BS4865:part 2 - spiral wound for BS4504 flanges
13010 = BS3381 - spiral wound for BS1560 flanges
bolting
13200 = BS4882 metric series bolting
13210 = BS4882 inch series bolting
dummy
13999 = dummy BS code

CL576, Table Suffix/End Standard - Green (999)


NOTE: Codelist numbers have been reserved as follows:
o US practices
2-99
o European practices 1 (DIN)
100-199
o European practices 2 (British)
200-299
o European practices 3 (Finnish, French, etc.
300-399
o International practices 1 (JIS)
400-499
o International practices 2 (Australian, etc.)
500-599
o Company practices
900-999
1 = [Blank]
US Practice Table Suffixes, 2-99
5 = Default
[See below for definition]
6 = PDS-1
[See specific table for details]
7 = PDS-2
[See specific table for details]
8 = PDS-3
[See specific table for details]
10 = ID Duct
[Nominal diameter based on inside diameter]
12
15
22
23
24
29
30
33
37

=
=
=
=
=
=
=
=
=

ANSI-B16.12
ANSI-B16.15
ANSI-B16.22
ANSI-B16.23
ANSI-B16.24
ANSI-B16.36
ANSI-B16.42
ANSI-B1.20.3
ANSI-B1.20.7

[Cast iron drainage fittings]


[Cast bronze fittings]
[Copper solder joint pressure fittings]
[Copper solder joint drainage fittings]
[Bronze flanges]
[Orifice flanges]
[Ductile iron flanges and fittings]
[Dryseal pipe threads]
[Hose coupling screw threads]

40 = ASME BPE-97 (PE)


41 = ASME BPE-97 (MCE)
45 = ASTM-A74
46 = ASTM-C76
Pipe]
47 = ASTM-C700
Perfor
49 = AWWA-C110
50 = AWWA-C115

[Cast iron S-XH soil pipe and fittings]


[Reinforced Concrete Culvert, Storm Drain and Sewer
[Extra Strength and Standard Strength Clay Pipe and
Clay Pipe]
[Iron fittings]
[Iron pipe and fittings]

Plant Design System (PDS) Reference Data Manager (PD_Data)

513

Appendix: Codelists
55 = AWWA-C151
[Ductile iron pipe]
60 = AWWA-C207 Cl.B & D, ring
[Steel slip-on flanges CL86, CL150, CL175]
61 = AWWA-C207 Cl.B & D, hub
[Steel slip-on flanges CL86, CL150, CL175]
62 = AWWA-C207 Cl.E, hub
[Steel slip-on flanges CL275]
70 = API-5LE
[Polyethylene fittings]
75 = API-6A
[Wellhead flanges and fittings]
79 = API-605-B
[API-605 blind flanges. These are based on API-605
flange
bolt diameters and MSS-SP44 flange thicknesses]
80 = MSS-SP-44-NB
[MSS non-blind flanges]
81 = MSS-SP-44-B
[MSS blind flanges]
85
86
87
88
90
91
92
93
94
95
96
97
98
99

=
=
=
=
=
=
=
=
=
=
=
=
=
=

Crosby
Consolidated
Lonergan
Top Line
Tube-Turn
Dow
Aloyco
Yarway
Teledyne Farris 1
R & G Sloane
American DI Pipe
Gladding McBean [Vitrified clay S-XS pipe and fittings]
Taylor Forge
Vendor 4

CL No. 5 is used to define the "Default for end type", which


represents the basis on which most US-practice generic piping tables
for dimensional parameters will be defined. The system will default
to table suffix "5" when dimensions from a male termination type
table are required in defining the component but the component ends
are other than male termination. The basis for this table suffix
will be as follows:
End Termination Type
Basis for Table Values
Flat-face flanged.................ANSI-B16.1 or B16.5
Raised-face flanged...............ANSI-B16.1, B16.5, API-605 or
MSS-SP-42,
in this order of precedence
RTJ-face flanged..................ANSI-B16.5
Tongue/male-face flanged..........ANSI-B16.5
Groove/female-face flanged........ANSI-B16.5
Flat-face lap-flanged.............ANSI-B16.5 with stub end thickness
ignored.

514

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
Raised-face lap-flanged...........ANSI-B16.5 with stub end thickness
ignored.
RTJ-face lap-flanged..............ANSI-B16.5 with stub end thickness
ignored.
Tongue/male-face lap-flanged......ANSI-B16.5 with stub end thickness
ignored.
Groove/female-face lap-flanged....ANSI-B16.5 with stub end thickness
ignored.
All thru-bolted...................For sizes and ratings for which API-590
applie
the value of parameter "P" shall be
taken from
API-590. For sizes and ratings for which
APIdoes
not apply, the bolt circle diameter from
ANSI-B16.1, B16.5, API-605 or
MSS-SP-42, in th
order of precedence, less one bolt
diameter l
1/8 inch will be used for parameter "P".
Male RTJ-face thru-bolted with cap screws....................None
Flat-face thru-bolted with cap screws........................None
Raised-face thru-bolted with cap screws......................None
RTJ-face thru-bolted with cap screws.........................None
Flat-full-face thru-bolted........DOW
Male..............................ANSI-B36.10M, ANSI-B36-19M, API-5L,
API-5LE,
API-5LP, API-5LS or API-5LU
PVC & CPVC socket.................API-5LP, ASTM-D2466 or ASTM-D2467
Socketwelded......................For pressure ratings XXXX#s, per basis
defined
in the applicable generic tables;
for pressure ratings CLXXXXs and
OTXXXXs, per
ANSI-B16.11 and ANSI-B16.5.
Female threaded
thread engagement per Table 2.4 of
2630-33
..................................Forged steel.For pressure ratings
XXXX#s,

Plant Design System (PDS) Reference Data Manager (PD_Data)

515

Appendix: Codelists
defined in the applicable generic
tables; for
pressure ratings CLXXXXs and OTXXXXs,
per ANSI
and ANSI-B16.5. In all cases, thread
engagement
will be per Table 2.4 of 2630-33
descriptions in the applicable generic
tables.
In all cases, thread engagement will be
per
Table 2.4 of 2630-33
Female grooved....................Victaulic catalog G100E
Female quick connect..............
Female ferrule....................
Female hose.......................
Mechanical joint bell.............AWWA-C110
Gasket............................Not applicable
Bolt..............................Not applicable
Nut...............................Not applicable
User defined......................None
o European practices 1 (DIN) 100-199
Codelist numbers used for DIN European practice
Generic dimension data select flag access starts here
105 = Gen blt & fem end prep dim
111
112
113
114
115
116
117
118
119

=
=
=
=
=
=
=
=
=

Blt
Blt
Blt
Blt
Blt
Blt
Blt
Blt
Blt

dim
dim
dim
dim
dim
dim
dim
dim
dim

for
for
for
for
for
for
lap
for
for

cast steel flanges


cast iron flanges
oval screwed flanges
screwed flanges
sold & weld flanges
lap flanges
flanges w/ plain collars
loose flanges w/ weld neck
loose flanges in enamelled components

125 = OD acc to DIN 2631 Reihe 1


126 = OD acc to DIN 2631 Reihe 2
129 = OD for plastic pipes
130 = OD acc to DIN 2445-1 PN 100
131 = OD acc to DIN 2445-1 PN 160

516

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
132 = OD acc to DIN 2445-1 PN 250
133 = OD acc to DIN 2445-1 PN 320
134 = OD acc to DIN 2445-1 PN 400
140
141
142
143
144

=
=
=
=
=

OD
OD
OD
OD
OD

acc
acc
acc
acc
acc

to
to
to
to
to

DIN
DIN
DIN
DIN
DIN

2445-2
2445-2
2445-2
2445-2
2445-2

PN
PN
PN
PN
PN

64-100
160
250
320
400

150 = OD acc to DIN 2391


160 = OD acc to DIN 2393
170 = OD acc to DIN 2440
171 = OD acc to DIN 2441
179 = OD for threaded components
British Standards
205 = default metric
206 = default converted imperial
210 = plate flanges BS4504

CL577, Table Suffix/End Standard - Red (999)


NOTE: Codelist numbers have been reserved as follows:
o US practices
2-99
o European practices 1 (DIN)
100-199
o European practices 2 (British)
200-299
o European practices 3 (Finnish, French, etc.
300-399
o International practices 1 (JIS)
400-499
o International practices 2 (Australian, etc.)
500-599
o Company practices
900-999
1 = [Blank]
US Practice Table Suffixes, 2-99
5 = Default
[See below for definition]
6 = PDS-1
[See specific table for details]
7 = PDS-2
[See specific table for details]
8 = PDS-3
[See specific table for details]
10 = ID Duct
[Nominal diameter based on inside diameter]
12
15
22
23
24
29

=
=
=
=
=
=

ANSI-B16.12
ANSI-B16.15
ANSI-B16.22
ANSI-B16.23
ANSI-B16.24
ANSI-B16.36

[Cast iron drainage fittings]


[Cast bronze fittings]
[Copper solder joint pressure fittings]
[Copper solder joint drainage fittings]
[Bronze flanges]
[Orifice flanges]

Plant Design System (PDS) Reference Data Manager (PD_Data)

517

Appendix: Codelists
30 = ANSI-B16.42
33 = ANSI-B1.20.3
37 = ANSI-B1.20.7

[Ductile iron flanges and fittings]


[Dryseal pipe threads]
[Hose coupling screw threads]

40 = ASME BPE-97 (PE)


41 = ASME BPE-97 (MCE)
45 = ASTM-A74
46 = ASTM-C76
Pipe]
47 = ASTM-C700
Perfor

[Cast iron S-XH soil pipe and fittings]


[Reinforced Concrete Culvert, Storm Drain and Sewer
[Extra Strength and Standard Strength Clay Pipe and
Clay Pipe]

49
50
55
60

=
=
=
=

AWWA-C110
AWWA-C115
AWWA-C151
AWWA-C207 Cl.B &

[Iron fittings]
[Iron pipe and fittings]
[Ductile iron pipe]
D, ring
[Steel slip-on flanges CL86, CL150, CL175]
61 = AWWA-C207 Cl.B & D, hub
[Steel slip-on flanges CL86, CL150, CL175]
62 = AWWA-C207 Cl.E, hub
[Steel slip-on flanges CL275]
70 = API-5LE
75 = API-6A
79 = API-605-B
flange

[Polyethylene fittings]
[Wellhead flanges and fittings]
[API-605 blind flanges. These are based on API-605

80 = MSS-SP-44-NB
81 = MSS-SP-44-B
85
86
87
90
91
92
93
94
95
96
97
98
99

=
=
=
=
=
=
=
=
=
=
=
=
=

bolt diameters and MSS-SP44 flange thicknesses]


[MSS non-blind flanges]
[MSS blind flanges]

Crosby
Consolidated
Lonergan
Tube-Turn
Dow
Aloyco
Yarway
Teledyne Farris 1
R & G Sloane
American DI Pipe
Gladding McBean [Vitrified clay S-XS pipe and fittings]
Taylor Forge
Vendor 4

CL No. 5 is used to define the "Default for end type", which


represents the basis on which most US-practice generic piping tables
for dimensional parameters will be defined. The system will default
to table suffix "5" when dimensions from a male termination type
table are required in defining the component but the component ends
are other than male termination. The basis for this table suffix
will be as follows:

518

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
End Termination Type
Basis for Table Values
Flat-face flanged.................ANSI-B16.1 or B16.5
Raised-face flanged...............ANSI-B16.1, B16.5, API-605 or
MSS-SP-42,
in this order of precedence
RTJ-face flanged..................ANSI-B16.5
Tongue/male-face flanged..........ANSI-B16.5
Groove/female-face flanged........ANSI-B16.5
Flat-face lap-flanged.............ANSI-B16.5 with stub end thickness
ignored.
Raised-face lap-flanged...........ANSI-B16.5 with stub end thickness
ignored.
RTJ-face lap-flanged..............ANSI-B16.5 with stub end thickness
ignored.
Tongue/male-face lap-flanged......ANSI-B16.5 with stub end thickness
ignored.
Groove/female-face lap-flanged....ANSI-B16.5 with stub end thickness
ignored.
A
ll thru-bolted...................For sizes and ratings for which API-590
applies
the value of parameter "P" shall be taken
from
API-590. For sizes and ratings for which
API does
not apply, the bolt circle diameter from
ANSI-B16.1, B16.5, API-605 or MSS-SP-42,
in th
order of precedence, less one bolt
diameter l
1/8 inch will be used for parameter "P".
Male RTJ-face thru-bolted with
cap screws........................None
Flat-face thru-bolted with
cap screws........................None
Raised-face thru-bolted with
cap screws........................None
RTJ-face thru-bolted with
cap screws........................None
Flat-full-face thru-bolted........DOW

Plant Design System (PDS) Reference Data Manager (PD_Data)

519

Appendix: Codelists
Male..............................ANSI-B36.10M, ANSI-B36-19M, API-5L,
API-5LE,
API-5LP, API-5LS or API-5LU
PVC & CPVC socket.................API-5LP, ASTM-D2466 or ASTM-D2467
Socketwelded......................For pressure ratings XXXX#s, per basis
defined
in the applicable generic tables;
for pressure ratings CLXXXXs and
OTXXXXs, per
ANSI-B16.11 and ANSI-B16.5.
Female threaded
thread engagement per Table 2.4 of
2630-33
..................................Forged steel.For pressure ratings
XXXX#s,
defined in the applicable generic
tables; for
pressure ratings CLXXXXs and OTXXXXs,
per ANSI
and ANSI-B16.5. In all cases, thread
engagement
will be per Table 2.4 of 2630-33
descriptions in the applicable generic
tables.
In all cases, thread engagement will be
per
Table 2.4 of 2630-33
Female grooved....................Victaulic catalog G100E
Female quick connect..............
Female ferrule....................
Female hose.......................
Mechanical joint bell.............AWWA-C110
Gasket............................Not applicable
Bolt..............................Not applicable
Nut...............................Not applicable
User defined......................None
o European practices 1 (DIN) 100-199
Codelist numbers used for DIN European practice
Generic dimension data select flag access starts here

520

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
105 = Gen blt & fem end prep dim
111
112
113
114
115
116
117
118
119

=
=
=
=
=
=
=
=
=

Blt
Blt
Blt
Blt
Blt
Blt
Blt
Blt
Blt

dim
dim
dim
dim
dim
dim
dim
dim
dim

for
for
for
for
for
for
lap
for
for

cast steel flanges


cast iron flanges
oval screwed flanges
screwed flanges
sold & weld flanges
lap flanges
flanges w/ plain collars
loose flanges w/ weld neck
loose flanges in enamelled components

125 = OD acc to DIN 2631 Reihe 1


126 = OD acc to DIN 2631 Reihe 2
129 = OD for plastic pipes
130
131
132
133
134

=
=
=
=
=

OD
OD
OD
OD
OD

acc
acc
acc
acc
acc

to
to
to
to
to

DIN
DIN
DIN
DIN
DIN

2445-1
2445-1
2445-1
2445-1
2445-1

PN
PN
PN
PN
PN

100
160
250
320
400

140
141
142
143
144

=
=
=
=
=

OD
OD
OD
OD
OD

acc
acc
acc
acc
acc

to
to
to
to
to

DIN
DIN
DIN
DIN
DIN

2445-2
2445-2
2445-2
2445-2
2445-2

PN
PN
PN
PN
PN

64-100
160
250
320
400

150 = OD acc to DIN 2391


160 = OD acc to DIN 2393
170 = OD acc to DIN 2440
171 = OD acc to DIN 2441
179 = OD for threaded components
181
182
183
184
185

=
=
=
=
=

Wallthickness
Wallthickness
Wallthickness
Wallthickness
Wallthickness

Reihe
Reihe
Reihe
Reihe
Reihe

1
2
3
4
5

191
192
193
194
195

=
=
=
=
=

Wallthickness
Wallthickness
Wallthickness
Wallthickness
Wallthickness

selection
selection
selection
selection
selection

1
2
3
4
5

British Standards
205 = default metric
206 = default converted imperial
210 = plate flanges BS4504

Plant Design System (PDS) Reference Data Manager (PD_Data)

521

Appendix: Codelists

CL578, Weight Code (399)


NOTE: Codelist numbers 2-99 have been reserved for values that
apply to US practices. Codelist numbers 100-399 have been reserved
for values that apply to practices in other countries.
1 = [Blank]
US Practice Weight Codes, 2-99
9 = 35 pcf
[Vitrified clay]
10 = 57 pcf
[Polypropylene]
16 = 88 pcf
[PVC]
22 = 97 pcf
[CPVC]
28 = 111 pcf
[FRP, Kynar]
30 = 150 pcf
[Reinforced concrete pipe]
34 = 165 pcf
[Aluminum]
40 = 260 pcf
[Titanium]
46 = 450 pcf
[Iron]
47 = 450 pcf
[Standard thk cement linin, ductile iron]
48 = 450 pcf
[Double thk cement lining ductile iron]
52 = 490 pcf
[Carbon steel, low Cr alloy steel, stainless steel]
58 = 490 pcf
[Cement lined carbon steel]
64 = 525 pcf
[Brass, Inconel]
70 = 555 pcf
[Bronze, copper, Monel, nickel]
76 = 570 pcf
[Hastelloy]
European Practice Weight Codes, 101-199
101 = [Blank]
111
112
113
114
115
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146

522

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Weight
Weight
Weight
Weight
Weight
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

selection flag 1
selection flag 2
selection flag 3
selection flag 4
selection flag 5
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN
[Acc. to DIN

3202-F1/K1/V1]
3202-F2/S2/K2/M2/V2]
3202-F3/S3/K3/M3]
3202-F4/K4/M4]
3202-F5/S5/K5/M5]
3202-F6/M6]
3202-F7/S7]
3202-F8/S8/M8]
3202-F9/S9/M9]
3202-S10/M10]
3202-F11/M11]
3202-S12]
3202-S13]
3202-S14/M14]
3202-F15/M15]
3202-F16]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

17
18
19
-
21
-
-
-
-
-
-
-
-
-
31
32
33
34
-
36
-
-
-

[Acc. to DIN 3202-F17]


[Acc. to DIN 3202-F18]
[Acc. to DIN 3202-F19]
[Not existent under DIN 3202]
[Acc. to DIN 3202-V21]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Acc. to DIN 3202-S31]
[Acc. to DIN 3202-F32/M32]
[Acc. to DIN 3202-F33/M33]
[Acc. to DIN 3202-F34]
[Not existent under DIN 3202]
[Acc. to DIN 3202-M36]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]

British Standards numbers (200-299)


units kg per cubic metre
201 = [Blank]
209
210
216
222
228
230
234
240
246
247
248
252
253
254
258
264
270
276

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

561 km3
913 km3
1410 km3
1554 km3
1778 km3
2403 km3
2643 km3
4165 km3
7208 km3
7208 km3
7208 km3
7849 km3
7849 km3
7849 km3
7849 km3
8410 km3
8890 km3
9130 km3

[polypropylene]
[pvc]
[cpvc]
[FRP, Kynar]
[Aluminium]
[Titanium]
[Iron]
[CS]
[low alloy st]
[SS]
[8mm thk cement lined CS]
[Brass, Inconel]
[Bronze, copper, Monel, Nickel]
[Hastelloy]

CL990, Types of Piping Commodity Data Forms


1 = General Fittings

Plant Design System (PDS) Reference Data Manager (PD_Data)

523

Appendix: Codelists
2 = Pipe Bends

3 = Orifice Flanges
4 = Branch Nipples
5 = Branch Reinforcement
21 = Valves

41 = Piping

42 = Tubing

61 = Gaskets

62 = Bolts

63 = Nuts

100
100
150
200
250

299
149
199
249
299

values are for Piping Specialties


range of values are for specific specialties
range of values are for typical specialties
range of values are for specific valves
range of values are for typical valves

100
150
200
250

=
=
=
=

Specific - General
Typical - General
Specific - Valve
Typical - Valve

300
300
350
400
450

499
349
399
449
499

300
350
400
450

=
=
=
=

Specific - General
Typical - General
Specific - Valve
Typical - Valve

values are for Instruments


range of values are for specific instruments
range of values are for typical instruments
range of values are for specific valves
range of values are for typical values

CL999, Standard Note Title (2000)


NOTE: In editing this codelist set, do not change the meaning of
existing codelist values.
1 = [Blank]
31 = Object Types for Mass Annotation
35 = Approval Status
36 = Structural Approval Status
37 = HVAC Approval Status
50 = Hold Status
69 = Equipment Division
125 = Fluid Code
130 = Construction Status
145 = Materials Grade
148 = Materials Description
160 = Responsibility
180 = Fabrication Category
190 = Coating Requirements

524

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
200 = Heat Tracing Requirements
210 = Heat Tracing Media
220 = Insulation Purpose
230 = Cleaning Requirements
330 = End Preparation
332 = Schedule / Thickness Override
340 = Safety Classification
360 = Stress Analysis Requirements
365 = Reporting Requirements
366 = Requirement to Reconstruct
380 = Piping Component Type
390 = Action
400 = Commodity Option
420 = Piping Component Data Source
425 = Piping/Tubing Type/Source
430 = Instrument Component Data Source
499 = Piping Notes
530 = Accessory / Item Type
550 = Operator / Actuator Type
570 = Design Standard
572 = Wall Thickness Equation
575 = Geometry Standard
576 = Table Suffix / End Standard - Green
577 = Table Suffix / End Standard - Red
578 = Weight Code
990 = Spec Writer Data Form Type
999 = Standard Note Title
1010 = Area Units
1028 = Weight Units
1056 = Temperature Units
1064 = Pressure Units
1074 = Density Units
1100 = Weld Type
1162 = Force Units
1201 = Drawing Scale
1202 = Drawing Size
1203 = Interference Manager Approval Status
1204 = Interference Clash Type
1205 = Interference Manager Action
1207 = Interference Manager Approval Method
1208 = Clash Checking Option
1209 = Clash Checking Volume Filter Option
1310 = Report Source
1312 = Report Type
1410 = Design Review Type
1605 = Model Status
1610 = Force Units for FrameWorks Plus
1620 = Drawing View Direction
1630 = Drawing View Composition Status
1710 = Document Type
1720 = Document Sub-Type
1900 = Isometric Drawing Type
2000 = Orthographic Drawing Type

Plant Design System (PDS) Reference Data Manager (PD_Data)

525

Appendix: Codelists

CL1010, Area Units (25)


Convert to Destination Unit
in CL
No
Unit Name
1
ft2
1.0* E+00
3
in2
6.944 444 E-03
5
yd2
9.0* E+00
7
mi2
2.787 840 E+07
10
mm2
1.076 391 E-05
12
cm2
1.076 391 E-03
14
m2
1.076 391 E+01
16
km2
1.076 391 E+07
25
[Blank]
-9999.

526

Convert To First Unit

Dest. Unit
m2

Factor
9.290 304* E-02

A
0.0

cm2

6.451 6* E+00

0.0

m2

8.361 274 E-01

0.0

km2

2.589 988 E+00

0.0

mm2

0.0

mm2

1.0* E+02

0.0

cm2

1.0* E+04

0.0

m2

1.0* E+06

0.0

-9999.

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL1028, Mass Units (40)


Convert to Destination Unit
in CL
No
Unit Name
1
lb
1.0* E+00
3
grain
1.428 571 E-04
9
USton
2.0* E+03
11
UKton
2.24* E+03
20
(Mu)g
2.204 622 E-09
22
mg
2.204 622 E-06
24
g
2.204 622 E-03
26
kg
2.204 622 E+00
28
Mg
2.204 622 E+03
40
[Blank]
-9999.

Convert To First Unit

Dest. Unit
kg

Factor
4.535 924 E-01

A
0.0

mg

6.479 891 E+01

0.0

Mg

9.071 847 E-01

0.0

Mg

1.016 047 E+00

0.0

(Mu)g

0.0

mg

0.0

0.0

kg

0.0

Mg

0.0

-9999.

CL1056, Temperature Units (15)


Convert to Destination Unit
in CL
No
Unit Name
1
degF
1.0* E+00
2
degC
1.8* E+00
3
degR
0.0* E+00
4
K
1.8* E+00
15
[Blank]
-9999.

Convert To First Unit

Dest. Unit
degC

Factor
(degF - 32)/1.8

A
0.0

degC

+3.2* E+01

5/9

-4.596 900 E+02

-4.596 900 E+02

-9999.

CL1064, Pressure Units (40)


NOTE: New entries in this codelist cannot be added by the user.
Changes will NOT be recognized unless the software is changed to
use them.

Plant Design System (PDS) Reference Data Manager (PD_Data)

527

Appendix: Codelists
Convert
in CL
No
Unit Name
B
1
psig [gage]
1.0* E+
2
psi [absolute]
E+01 1.0* E+00
4
inH2O [absolute]
E+01 3.609 119 E-02
6
inH2O @ 32degF
E+01 3.613 010 E-02
7
inHg [absolute]
E+01 4.897 707 E-01
8
mmHg [absolute]
E+01 1.933 672 E-02
9
atm [absolute]
E+01 1.469 595 E+01
10
bar [absolute]
E+01 1.450 377 E+01
11
bar (gage) [gage]
1.450 377 E+01
13
dyn/cm2 [absolute]
E+01 1.450 377 E-05
15
mmH2O [absolute]
E+01 1.422 295 E-03
16
inHg @ 32degF
E+01 4.911 054 E-01
17
kPa [absolute]
E+01 1.450 377 E-01
18
MPa [absolute]
E+01 1.450 377 E+02
19
Pa [absolute]
E+01 1.450 377 E-04
20
kg/cm*2 (gage) [gage]
1.422 334 E+01
21
kg/cm*2 [absolute]
E+01 1.422 334 E+01
22
Mpa_g
1.450 377 E+02
40
[Blank]
-9999.
67
kPa_g
1.450 377 E-01

to Destination Unit
Dest. Unit

Convert To First Unit

Factor

kPa

0.0

kPa

6.894 757 E+00

-1.469 595

kPa

2.488 4 E-01

-1.469 595

kPa

2.491 14 E-01

-1.469 595

kPa

3.376 85 E+00

-1.469 595

kPa

1.333 22 E-01

-1.469 595

kPa

1.013 250* E+02 -1.469 595

kPa

1.0* E+02

psig

1.450 377 E+01

Pa

1.0* E-01

-1.469 595

kPa

9.806 38 E-03

-1.469 595

kPa

3.386 38 E+00

-1.469 595

kPa

-1.469 595

kPa

1.0* E+03

-1.469 595

Pa

-1.469 595

psig

1.422 334 E+01

kPa

9.806 65 E+01

psig

1.450 377 E+02

psig

1.450 377 E-01

-1.469 595
0.0

0.0
-1.469 595
0.0
-9999.
0.0

CL1074, Density Units (35)


Convert to Destination Unit

Convert To First

Unit in CL

528

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
No
B
1
1.0* E+00
3
6.228 834
5
7.480 519
7
1.0* E+03
9
1.728 000
11
2.0* E+03
17
-9999.
20
6.242 797
22
6.242 797
24
6.242 797
26
6.242 797
35
-9999.

Unit Name

Dest. Unit

Factor

lb/ft3

kg/m3

1.601 846 E+01

0.0

lb/UKgal
E+00
lb/USgal
E+00
kip/ft3

kg/m3

9.977 633 E+01

0.0

kg/m3

1.198 264 E+02

0.0

kg/m3

1.601 846 E+04

0.0

lb/in3
kg/m3
E+03
USton/ft3 kg/m3

2.767 990 E+04

0.0

3.203 692 E+04

0.0

degAPI

kg/m3

Use API2564 Tbl -9999.

kg/m3
E-02
g/cm3
E+01
kg/L
E+01
kg/dm3
E+01
[Blank]

kg/m3

0.0

kg/dm3

0.0

kg/m3

1.0* E+03

0.0

kg/m3

1 E+03

0.0

-9999.

CL1100, Weld Type (100)


NOTE: Codelist numbers 0-19 have been reserved for shop welds,
numbers 20-29 have been reserved for field welds, and 30-39 have
been reserved for offshore welds. In editing this codelist set, do not
change the meaning of existing codelist values.
1 = [Blank]
2 = Pipe connector
11 = Shop weld
21 = Field weld at assembly site
22 = Field weld at job site
23 = Field weld at job site for loose flange
24 = Field fit weld at job site

CL1162, Force Units (40)


1 = lbf
3 = kipf
5 = UStonf
7 = UKtonf
20 = dyn

Plant Design System (PDS) Reference Data Manager (PD_Data)

529

Appendix: Codelists
22
24
26
28
40

=
=
=
=
=

mN
N
kgf
kN
[Blank]

CL1201, Drawing Scale (540)


(1-499) English System of Units
1 = [Blank]
104 = =1/8"= 1 0"
108 = =1/4"= 1 0"
112 = =3/8"= 1 0"
116 = =1/2"= 1 0"
124 = =3/4"= 1 0"
132 = =1"= 1 0"
164 = =2"= 1 0"
(500-599) Metric System of Units
500 = 1:10
510 = 1:4
530 = 1:2
540 = 1:1

CL1202, Drawing Size (199)


(1-99) English System of Units
1 = A
2 = B
3 = C
4 = D
5 = E
6 = F
(100-199) Metric System of Units
101 = A0
102 = A1
103 = A2
104 = A3
105 = A4

CL1203, Interference Manager Approval Status (99)


1 = Unapproved
2 = Approved
99 = Cleared

530

[User has approved clash]


[Software detected that clash has been fixed]

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL1204, Interference Clash Type (10)


1 = ' Hard versus Hard' ;
2 = ' Hard versus Soft' ;
3 = ' Hard versus Construction' ;
4 = ' Soft versus Soft' ;
5 = ' Soft versus Construction' ;
6 = ' Construct vs Construct=Construction versus Construction' ;
105 = ' Hard vs Fproof' ;
106 = ' Hard vs Insul' ;
110 = ' Hard vs HardMaint' ;
111 = ' Hard vs HardAccess' ;
112 = ' Hard vs HardSafety' ;
113 = ' Hard vs HardOperating' ;
120 = ' Hard vs SoftMaint' ;
121 = ' Hard vs SoftAccess' ;
122 = ' Hard vs SoftSafety' ;
123 = ' Hard vs SoftOperating' ;
206 = ' Soft vs Insul' ;
220 = ' Soft vs SoftMaint' ;
221 = ' Soft vs SoftAccess' ;
222 = ' Soft vs SoftSafety' ;
223 = ' Soft vs SoftOperating' ;
501 = ' Fproof vs Hard' ;
502 = ' Fproof vs Soft' ;
504 = ' Fproof vs CT' ;
505 = ' Fproof vs Fproof' ;
506 = ' Fproof vs Insul' ;
510 = ' Fproof vs HardMain' ;
511 = ' Fproof vs HardAccess' ;
512 = ' Fproof vs HardSafety' ;
513 = ' Fproof vs HardOperat' ;
520 = ' Fproof vs HardMain' ;
521 = ' Fproof vs HardAccess' ;
522 = ' Fproof vs HardSafety' ;
523 = ' Fproof vs HardOperat' ;
602 = ' Insul vs Soft' ;
604 = ' Insul vs CT' ;
606 = ' Insul vs Insul' ;
620 = ' Insul vs SoftMain' ;
621 = ' Insul vs SoftAccess' ;
622 = ' Insul vs SoftSafety' ;
623 = ' Insul vs SoftOperat' ;
1001 = ' HardMain vs Hard' ;
1002 = ' HardMain vs Soft' ;
1004 = ' HardMain vs CT' ;
1005 = ' HardMain vs Fproof' ;
1006 = ' HardMain vs Insul' ;
1010 = ' HardMain vs HardMain' ;
1012 = ' HardMain vs HardSafety' ;
1013 = ' HardMain vs HardOperat' ;

Plant Design System (PDS) Reference Data Manager (PD_Data)

531

Appendix: Codelists
1020
1021
1022
1023
1101
1102
1104
1105
1106
1110
1111
1112
1113
1120
1121
1122
1123
1201
1202
1204
1205
1206
1210
1211
1212
1213
1220
1221
1222
1223
1301
1302
1304
1305
1306
1310
1311
1312
1313
1320
1321
1322
1323
2002
2004
2006
2020
2021
2022
2023
2102
2104
2106
2120

532

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

HardMain vs SoftMain' ;
HardMain vs SoftAccess' ;
HardMain vs SoftSafety' ;
HardMain vs SoftOperat' ;
HardAcc vs Hard' ;
HardAcc vs Soft' ;
HardAcc vs CT' ;
HardAccess vs Fproof' ;
HardAccess vs Insul' ;
HardAcc vs HardMain' ;
HardAcc vs HardAcc' ;
HardAcc vs HardSafety' ;
HardAcc vs HardOperat' ;
HardAcc vs SoftMain' ;
HardAcc vs SoftAcc' ;
HardAcc vs SoftSafety' ;
HardAcc vs SoftOperat' ;
HardSafety vs Hard' ;
HardSafety vs Soft' ;
HardSafety vs CT' ;
HardSafety vs Fproof' ;
HardSafety vs Insul' ;
HardSafety vs HardMain' ;
HardSafety vs HardAcc' ;
HardSafety vs HardSafety'
HardSafety vs HardOperat'
HardSafety vs SoftMain' ;
HardSafety vs SoftAccess'
HardSafety vs SoftSafety'
HardSafety vs SoftOperat'
HardOperat vs Hard' ;
HardOperat vs Soft' ;
HardOperat vs CT' ;
HardOperat vs Fproof' ;
HardOperat vs Insul' ;
HardOperat vs HardMain' ;
HardOperat vs HardAccess'
HardOperat vs HardSafety'
HardOperat vs HardOperat'
HardOperat vs SoftMain' ;
HardOperat vs SoftAccess'
HardOperat vs SoftSafety'
HardOperat vs SoftOperat'
SoftMain vs Soft' ;
SoftMain vs CT' ;
SoftMain vs Insul' ;
SoftMain vs SoftMain' ;
SoftMain vs SoftAccess' ;
SoftMain vs SoftSafety' ;
SoftMain vs SoftOperat' ;
SoftAccess vs Soft' ;
SoftAccess vs CT' ;
SoftAccess vs Insul' ;
SoftAccess vs SoftMain' ;

;
;
;
;
;

;
;
;
;
;
;

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
2121
2122
2123
2202
2204
2206
2220
2221
2222
2223
2302
2304
2306
2320
2321
2322
2323

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

SoftAccess
SoftAccess
SoftAccess
SoftSafety
SoftSafety
SoftSafety
SoftSafety
SoftSafety
SoftSafety
SoftSafety
SoftOperat
SoftOperat
SoftOperat
SoftOperat
SoftOperat
SoftOperat
SoftOperat

vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs
vs

SoftAccess'
SoftSafety'
SoftOperat'
Soft' ;
CT' ;
Insul' ;
SoftMain' ;
SoftAccess'
SoftSafety'
SoftOperat'
Soft' ;
CT' ;
Insul' ;
SoftMain' ;
SoftAccess'
SoftSafety'
SoftOperat'

;
;
;

;
;
;

;
;
;

CL1205, Interference Manager Action (10)


1
2
3
4

=
=
=
=

No Action by user
Approve Real Clash
Approve False Clash
Transfer Responsibility

CL1207, Interference Manager Approval Method(10)


1 = Not Approved
2 = Accepted by Graphical Review
3 = Accepted from List

CL1208, Clash Checking Option


1
2
3
4

=
=
=
=

Unknown
Project Mode
Design Area Mode
Pre-defined Volume Mode

Plant Design System (PDS) Reference Data Manager (PD_Data)

533

Appendix: Codelists

CL1209, Clash Checking Volume Filter Option


1 = Volume Filter Is Inactive
2 = Volume Filter Is Active

CL1310, Report Source (99)


NOTE: In editing this codelist set, do not change the meaning of
existing codelist values. Codelist values are reserved as follows:
0-10 from design data, 11-20 from project data, 21-30 reference
data.
1 = MTO Report
2 = Drawing Report
3 = PID Report Header
11 = Project Control Report
12 = Clash Management Report
21 = Piping Job Spec Report
22 = Table Checker Report

CL1312, Report Type (999)


NOTE: Document types defined below must be numerically identical
to those defined in CL1720, Document Type; codelist numbers used
must not exceed 999. In editing this codelist set, do not change
the meaning of existing codelist values.
601
682
685
687
689
690
692
696

=
=
=
=
=
=
=
=

Piping RDB Reports


Equipment List
Piping Line List
Piping Segments Report
Piping Components MTO Report
Pipe Supports Report
Instrument List
Piping Release Report

CL1410, Design Review Type (10)


NOTE: In editing this codelist set, do not change the meaning of
existing codelist values.
1 = Client Review
2 = Informal Review

534

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists

CL1605, Model Status


1 = Undefined
11 = Preliminary
12 = Temporary
21 = Permanent

CL1610, Force Units for FrameWorks Plus (40)


1
2
3
4

=
=
=
=

LBS
KIPS
N
kN

CL1620, Drawing View Directions (7)


1
2
3
4
5
6
7

=
=
=
=
=
=
=

Plan
East Elevation
North Elevation
Isometric
West Elevation
South Elevation
Plan (Vertical)

CL1630, Drawing View Composition Status (4)


1
2
3
4

=
=
=
=

Drawing View Not Composed


Drawing View Composed
Composite Drawing View Not Composed
Composite Drawing View Composed

CL1710, Document Source (99)


NOTE: Do not make any new entries to this codelist. In editing
this codelist set, do not change the meaning of existing codelist values.
1 = Process RDB report
2 = Process TDB report
5 = Process TDB drawing
11 = P&I RDB report

Plant Design System (PDS) Reference Data Manager (PD_Data)

535

Appendix: Codelists
12 = P&I TDB report
15 = P&I TDB drawing
21 = Vessel RDB report
22 = Vessel TDB report
25 = Vessel TDB drawing
31 = Heat Transfer RDB report
32 = Heat Transfer TDB report
35 = Heat Transfer TDB drawing
41 = Mechanical RDB report
42 = Mechanical TDB report
45 = Mechanical TDB drawing
46 = Piping Specialty RDB report
47 = Piping Specialty TDB report
51 = Civil/Structural RDB report
52 = Civil/Structural TDB report
55 = Civil/Structural TDB drawing
61
62
65
67

=
=
=
=

Piping
Piping
Piping
Piping

RDB report
TDB report (PD_Report)
TDB drawing (PD_Draw)
isometric TDB drawing

71 = Instrument RDB report


72 = Instrument TDB report
75 = Instrument TDB drawing
81 = Electrical RDB report
82 = Electrical TDB report
85 = Electrical TDB drawing
91 = HVAC RDB report
92 = HVAC TDB report
95 = HVAC TDB drawing
99 = No planned PDS source

CL1720, Document Type (999)


NOTE: The PDS source of each document type is shown to the right
of the document type separated from it by the character | on the
basis of codelist numbers defined in CL1710, Document Source. In
editing this codelist set, respect the number ranges identified below.
(100-199) Process Documents
101 = Process RDB Reports | 1
121 = Process Flow Diagrams | 5

536

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
125
127
131
133
199

=
=
=
=
=

Materials of Construction Drawings | 5


Temperature/Pressure Diagrams | 5
Equipment Process Datasheets | 2
Instrument Process Datasheets | 2
Other Process Documents | 99

(200-299) Vessel Documents


201 = Vessel RDB Reports | 21
205 = Vessel Job Specifications | 99
211 = Vessel Requisitions | 22
231 = Reactor Drawings | 25
233 = Regenerator Drawings | 25
235 = Cyclone Drawings | 25
237 = Transfer Line Drawings | 25
239 = Tower Drawings | 25
241 = Drum Drawings | 25
243 = Tank Drawings | 25
245 = Silo Drawings | 25
247 = Stack Drawings | 25
299 = Other Vessel Documents | 99
(300-399) Heat Transfer Documents
301 = Heat Transfer RDB Reports | 31
305 = Heat Transfer Job Specifications | 99
311 = Heat Transfer Requisitions | 32
331 = Heat Transfer Drawings | 35
399 = Other Heat Transfer Documents | 99
(400-499) Mechanical Equipment Documents
401 = Mechanical RDB Reports | 41
405 = Mechanical Equipment Job Specifications | 99
411 = Mechanical Equipment Requisitions | 42
431 = Mechanical Equipment Drawings | 45
499 = Other Mechanical Equipment Documents | 99
(500-599) Civil/Structural Documents
501 = Civil/Structural RDB Reports | 51
505 = Civil/Structural Job Specifications | 99
511 = Civil/Structural Requisitions | 99
531 = Site Preparation Drawings | 99
535 = Foundation Location Drawings | 65
537 = Piling Drawings | 65
538 = Foundation Drawings | 55
540 = Structural Perspectives, Plans, Sections and Details | 65
545 = Concrete Structural Drawings | 55
550 = Steel Structural Drawings | 55
570 = Building Drawings | 99
599 = Other Civil/Structural Documents | 99
(600-699) Piping Documents
601 = Piping RDB Reports | 61
602 = Piping Specialty RDB Reports | 46
605 = Piping Job Specifications | 99
611 = Piping Commodity Requisitions | 99

Plant Design System (PDS) Reference Data Manager (PD_Data)

537

Appendix: Codelists
612
631
633
641
643
651
661
663
665
667
669
671
673
675
681
682
684
685
687
689
690
692
696
699

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Piping Specialty Requisitions | 47


P&IDs | 15
Hydrotest P&IDs | 15
Plot Plans | 65
Equipment Arrangement Drawings | 65
Piping Underground Drawings | 65
Equipment Orientations | 65
Piping One Line Drawings | 65
Piping Perspectives, Plans, Sections and Details | 65
Pipeline Alignment Drawings | 65
Piping Isometric Drawings | 67
Piping Spool Drawings | 67
Spring Hanger Drawings | 99
Pipe Support Details | 99
P&ID Equipment List | 12
Equipment List | 62
P&ID Line List | 12
Piping Line List | 62
Piping Segments Report | 62
Piping Components MTO Report | 62
Pipe Supports Report | 62
Instrument List | 62
Piping Release Report | 62
Other Piping Documents | 99

(700-799) Instrument Documents


701 = Instrument RDB Reports | 71
705 = Instrument Job Specifications | 99
711 = Instrument Requisitions | 72
721 = Instrument Logic Diagrams | 75
723 = Instrument Loop Diagrams | 75
731 = Instrument Location Plans | 65
733 = Instrument Control House/Panel Drawings | 99
735 = Instrument Hook Up Drawings | 75
737 = Instrument Heat Tracing Drawings | 75
739 = Instrument Wiring Drawings | 99
771 = Instrument Index | 72
799 = Other Instrument Documents | 99
(800-899) Electrical Documents
801 = Electrical RDB Reports | 81
805 = Electrical Job Specifications | 99
811 = Electrical Requisitions | 99
831 = Electrical One Line Diagrams | 99
841 = Electrical Area Classification Drawings | 65
851 = Electrical Underground Drawings | 65
861 = Electrical Power Drawings | 99
863 = Electrical Communications Drawings | 99
865 = Lighting Perspectives, Plans, Sections and Details | 65
867 = Electrical Heat Tracing Drawings | 99
899 = Other Electrical Documents | 99
(900-999) HVAC Documents
901 = HVAC RDB Reports | 91

538

Plant Design System (PDS) Reference Data Manager (PD_Data)

Appendix: Codelists
905
911
931
971
999

=
=
=
=
=

HVAC Job Specifications | 99


HVAC Requisitions | 99
HVAC Flow Diagrams | 99
HVAC Perspectives, Plans, Sections and Details | 65
Other HVAC Documents | 99

CL1900, Isometric Drawing Type


NOTE: In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1 = Fabrication
2 = Spool
3 = Stress

CL2000, PD_Draw Document Type (999)


NOTE: Document types defined below must be numerically identical
to those defined in CL1720, Document Type; codelist numbers used
must not exceed 999. In editing this codelist set, do not change
the meaning of existing codelist values.
535
537
540
641
643
651
661
663
665
667
731
841
851
865
971

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Foundation Location Drawings


Piling Drawings
Structural Perspectives, Plans, Sections and Details
Plot Plans
Equipment Arrangement Drawings
Piping Underground Drawings
Equipment Orientations
Piping One Line Drawings
Piping Perspectives, Plans, Sections and Details
Pipeline Alignment Drawings
Instrument Location Plans
Electrical Area Classification Drawings
Electrical Underground Drawings
Lighting Perspectives, Plans, Sections and Details
HVAC Perspectives, Plans, Sections and Details

This form allows you to manipulate various data libraries and database tables.
For more information on specific data and libraries, see Graphic Commodity Library Manager (on
page 199), Piping Assembly Library Manager (on page 386), and Physical Data Library Manager
(on page 208).

Plant Design System (PDS) Reference Data Manager (PD_Data)

539

Index
A
Abbreviations 227
About Library Merger 370
Add Entry to Material Description Library
95
Alphanumeric Labels 344
Appendix
Codelists 423
Reference Data Manager Error Messages
421

B
Batch Processes 29
Bend Deflection Table (G04) 158
Bends and Branches 198
Bolt Commodity Code Table 166
Bolts, Gaskets, and Flanges 198
Branch Insertion Tables 145
BRANCHID.LN File 148

C
CL1010, Area Units (25) 526
CL1028, Mass Units (40) 527
CL1056, Temperature Units (15) 527
CL1064, Pressure Units (40) 527
CL1074, Density Units (35) 528
CL1100, Weld Type (100) 529
CL1162, Force Units (40) 529
CL1201, Drawing Scale (540) 530
CL1202, Drawing Size (199) 530
CL1203, Interference Manager Approval
Status (99) 530
CL1204, Interference Clash Type (10) 531
CL1205, Interference Manager Action (10)
533
CL1207, Interference Manager Approval
Method(10) 533
CL1208, Clash Checking Option 533
CL1209, Clash Checking Volume Filter
Option 534
CL125, Fluid Code/Connector Type (999)
428
CL130, Construction Status (15) 432
CL1310, Report Source (99) 534
CL1312, Report Type (999) 534
CL1410, Design Review Type (10) 534

CL145, Materials Grade (4500) 433


CL148, Piping Materials Class Description
(31999) 462
CL160, Responsibility (25) 470
CL1605, Model Status 535
CL1610, Force Units for FrameWorks Plus
(40) 535
CL1620, Drawing View Directions (7) 535
CL1630, Drawing View Composition Status
(4) 535
CL1710, Document Source (99) 535
CL1720, Document Type (999) 536
CL180, Fabrication Category (99) 471
CL190, Coating Requirements (99) 471
CL1900, Isometric Drawing Type 539
CL200, Heat Tracing Requirements (10)
472
CL2000, PD_Draw Document Type (999)
539
CL210, Heat Tracing Media (60) 472
CL220, Insulation Purpose (40) 473
CL230, Cleaning Requirements (99) 473
CL31, Object Types for Orthographic
Drawings (40) 426
CL330, CP Type/Termination/Preparation
(999) 473
CL332, Schedule / Thickness Override 477
CL340, Safety Classification (99) 478
CL35, Approval Status (10) 427
CL36, Structural Approval Status (15) 427
CL360, Stress Analysis Requirements (15)
479
CL365, Reporting Requirements (25) 479
CL366, Requirement to Reconstruct (10)
479
CL37, HVAC Approval Status (10) 428
CL380, Piping Component Type (2500)
479
CL390, Action (40) 487
CL400, Option (999) 487
CL420, Piping Component Type/Source (25)
494
CL425, Piping/Tubing Type (25) 495
CL430, Instrument Component Type/Source
(25) 495
CL499, Piping Notes (999) 495
CL50, Hold Status (10) 428
CL530, Accessory/Item Type (125) 497
CL550, Operator Actuator Type (200) 498

Plant Design System (PDS) Reference Data Manager (PD_Data)

541

Index
CL570, Design Standard (200) 499
CL572, Wall Thickness Equation 499
CL575, Geometry Standard (31999) 499
CL576, Table Suffix/End Standard - Green
(999) 513
CL577, Table Suffix/End Standard - Red
(999) 517
CL578, Weight Code (399) 522
CL69, Equipment Divisions/Form Code (99)
428
CL990, Types of Piping Commodity Data
Forms 524
CL999, Standard Note Title (2000) 525
Clash Management Labels 345
Clear Error Messages 370
Commodity Code Attribute Message 345
Commodity Implied Data Command 104
Commodity Item Name Table (G02) 156
Common Tools on the PD_Shell Forms 24
Component Insulation Exclusion Data (231)
69
Component Mirror Table 170
Compress 200, 210, 324, 335, 388
Compress Destination Library 369
Compress Library 174, 348
Connect Point Data 196
Contents 370
Copy to Destination 369
Create Data 324
Create Label Attribute Data 353
Create Label Data 348
Create Label Graphic Data 351
Create Library 174, 200, 209, 284, 324,
335, 347, 388
Create Standard Note Type 336
Create/Batch Assembly Data 389
Create/Batch Graphic Commodity Data
201
Create/Batch Physical Commodity Data
211
Create/Batch Spec Tables 175
Create/Interactive Graphic Commodity Data
201
Create/Interactive Physical Commodity Data
210
Create/Interactive Piping Assembly Data
388
Create/Interactive Spec Tables 175
Create/Revise Instrument Specification Data
100
Create/Revise Piping Commodity Implied
Material Data 105

542

Create/Revise Piping Commodity


Specification Data 89
Create/Revise Piping Materials Class Data
84
Create/Revise Piping Specialty Specification
Data 97
Create/Revise Tap Properties Data 102

D
Data Retrieval from the Physical Data
Library 195
Data Security 32
Default End Preparation Table 172
Default Project Control Data 35
Delete 369
Delete Data 326
Delete Graphic Commodity Data 204
Delete Label Data 361
Delete Option 112
Delete Physical Commodity Data 213
Delete Piping Assembly Data 391
Delete Spec Tables 177
Delete Standard Note Data 339
Delivered Reference Data 18
Discrimination Data Creation Form 120,
299
Discrimination Data Deletion Form 124,
301
Discrimination Data Form 298
Discrimination Data Revision Form 122,
300
Displayable Attribute Labels 344
Displayable Attribute Message 344

E
Edit Label Description 369
Edit Label Number 369
Edit Menu 368
Example of Physical Data Look-Up 195
Exit 368
Extract Assembly Data 394
Extract Data 329
Extract Graphic Commodity Data 206
Extract Physical Commodity Data 216
Extract Spec Tables 180
Extract Standard Note Type 340

F
Features 75
Field Fit Length Table 170
File Menu 367

Plant Design System (PDS) Reference Data Manager (PD_Data)

Index
Fire and Safety Piping Components (6P4C
and 6Q4C) 231
Fittings (6P2C, 6P3C, 6Q2C, and 6Q3C)
230
Flange Insulation Exclusion Data (232) 71
Fluid Code Table 151
Format Creation/Revision Form 117, 296
Format Deletion Form 118, 297

G
Gasket Diameter Table 169
Gasket Separation Table 149
Generic Table for Bolted Ends (G10) 236
Generic Table for Female Ends (G30) 243
Generic Table for Male Ends (G20) 241
Generic Table for Studs in Bolted
Connections w/ Term Type (G12T) 239
Generic Table for Studs used in Bolted
Connections (G12) 237
Generic Table for Weight and Thickness
Data, Male Ends (G50) 244
Generic Tables 232
Graphic Commodity Data 183
Graphic Commodity Data Introduction 16
Graphic Commodity Library 183
Graphic Commodity Library Manager 199
Graphic Commodity Modules List 207

H
Help 29
Help Menu 370

I
Implied Data 94
Information 368
Instrument Body (I80 and P80) 264
Instrument Component Specification Data
(204) 58
Instrument Component Tables 264
Instrument Data Command 99
Instrument Operator (I81 and P81) 266
Introduction 13
Invert Selection 369
Isometric Drawing Labels 345

L
Label Description Library 343
Label Description Library Introduction 17
Label Description Library Manager 347
Label Library Merge Workflow 370
Label Library Merger 366

Label Library Merger Interface 367


Label Types 343
Library List 330
List Assembly Data 393
List Data 328
List Graphic Commodity Data 205
List of Piping Materials Classes Form 94
List Physical Commodity Data 216
List Spec Tables 180
List Standard Note Data 339
Load Database 341
Load, Replace, or Replace Commodity
Subset Options 110
Load/Revise Batch 286
Load/Revise Interactive 285
Long Material Description Library 279

M
Mass Annotation Options 358
Material Data in the Material Reference
Database 272
Material Description Data 269
Material Description Data Introduction 16
Material Description Library Manager 282
Material Reference Database Structure 41
Materials Data Table 142
MicroStation V7 Checker 415
MTO Tables and Functions 172

N
Neutral File Input 42
Nominal Piping Diameter Table 137
Notes for Graphic Commodity Data 196

O
Open Destination Library 368
Open Source Label Library 1 368
Open Source Label Library 2 368
Operator Mirror Table 171

P
Parametric Shape Definitions 192
PD Shell 21
PD_Shell Form Conventions 24
PDS Environment 21
Physical Data Definitions 187
Physical Data Library Manager 208
Physical Data Tables 194
Pipe Length Threshold Table (G07) 160
Pipe Support Tutorial Definition Manager
323

Plant Design System (PDS) Reference Data Manager (PD_Data)

543

Index
Pipe, Tubing, and Hose 199
Piping Assembly Language 373
Piping Assembly Library 373
Piping Assembly Library Introduction 17
Piping Assembly Library Manager 386
Piping Commodity Data Command 87
Piping Commodity Implied Material Data
(212) 66
Piping Commodity Size-Dependent Material
Data (211) 64
Piping Commodity Specification Data (202)
49
Piping Component Table for Empty Weight
based on GCP and RCP Data
(P61,P62,P63,P64,P65) 263
Piping Component Table for Empty Weight
based on GCP Data (P51,P52,P59) 258
Piping Component Table For Empty Weight
of Valves (P60A) 260
Piping Component Table For Empty Weight
of Valves, Overflow Data (P60B) 261
Piping Component Table for GCP Data
(P11A, P15A) 251
Piping Component Table for Operators and
Actuators (P31A) 256
Piping Component Table for Operators and
Actuators, Overflow Data (P31B) 257
Piping Component Table GCP Overflow
Data (P11B, P15B) 252
Piping Component Table Green and Red CP
Data (P21A, P25A, P26A, P27A, P28A,
P29A) 253
Piping Component Table Green and Red CP
Overflow Data
(P21B,P25B,P26B,P27B,P28B) 255
Piping Component Tables 245
Piping Component Tables for Specialty
Components 264
Piping Construction Tolerance Exclusion
Data (233) 73
Piping Job Spec Report Manager 114
Piping Job Specification 41
Piping Job Specification Introduction 15
Piping Job Specification Manager 107
Piping Job Specification Tables 135
Piping Job Specification Tables Command
173
Piping Materials Class Data (201) 45
Piping Materials Class Data Command 84
Piping Specialty Data Command 96
Piping Specialty Specification Data (203)
56
PJS Tables and Functions 135

544

Placing Taps in Assemblies 383


Preface PDS 11
Preferred Bolt Length Table (G11) 161
Project Organization 13
Proposed RDB Changes Report 410

R
RDB Options File 76
RDB Tables 155
Reference Data Archival 34
Reference Data Conflict Report 397
Reference Data Impact Report 407
Reference Data Location 35
Reference Data Manager 31
Reference Data Overview 14
Reference Data Setup 18
Reference Database Introduction 17
Reference Database Management Data 36
Reference Database Revision Manager
395
Replace Batch 287
Replace Interactive 286
Report Approval Form 131, 309
Report Assembly Data 392
Report Creation Form 126, 304
Report Data 327
Report Deletion Form 130, 308
Report Discrimination Data Form 119
Report Form 125, 303
Report Format Form 116, 295
Report Graphic Commodity Data 205
Report Label Data 361
Report Labels 345
Report Management Defaults Form 133,
311
Report Multiple Submit Form 131, 310
Report on Spec Tables 178
Report Option 112, 288
Report Physical Commodity Data 214
Report Standard Note Library Contents
338
Revise Data 325
Revise Graphic Commodity Data 202
Revise Label Data 358
Revise Physical Commodity Data 212
Revise Piping Assembly Data 390
Revise Report Form 128, 306
Revise Spec Tables 176
Revise Standard Note Type 336

S
Sample Piping Assembly Files 384

Plant Design System (PDS) Reference Data Manager (PD_Data)

Index
Sample Table Checker Output 312
Search Criteria Form 121
Segment Pipe Run Length Threshold Table
(G06) 159
Select All 368
Short Material Description Library 273
Spec Writer 74
Specialty Material Description Library 281
Specialty Piping Components (6P6C and
6Q6C) 231
Standard Note Library 331
Standard Note Library Introduction 17
Standard Note Library Manager 334
Standard Note Types List 342
Sub-Symbol Processor 187
Support Tutorial Definition Manager 323
Symbol Processors 186

W
Wall Thickness and Branch Reinforcement
Equations 152
Weld Clearance Table 167
Weld Graphics Dimensions Table 168
Weld Type Table 164
What's New in Reference Data Manager
(PD_Data) 12

T
Table Change Report 401
Table Checker 107, 291
Table Checker Form 293
Table Conventions 219
Table Formats and Naming Conventions
219
Table Requirements 228
Tables Required for Instrument Components
231
Tables Required for Piping Components
228
Tap Properties Data (205) 61
Tap Properties Data Command 102
Temperature and Pressure Service Limits
Table 136
Thickness Data Tables 140

U
Unapproved ==> Approved 174, 200, 285,
324, 335, 348, 388
Unapproved to Approved 210
Unselect All 369
Using the Report Commands 115, 294

V
Validate 369
Valves (6Q1C) 229
Variables for Generic Tables 232
Variables for Specific Tables 247
Verify RDB Library 417

Plant Design System (PDS) Reference Data Manager (PD_Data)

545

Das könnte Ihnen auch gefallen