1. Introduction
Tip
1.1
Explanation
Basis CD
Bluetooth
Port replicator
Recovery
Software patch
4 - 16
VAS 6150 starting with Basic CD 16 V2.00
2.
Documentation links
2.1
2.2
2.3
Service information
Here you will find all the information as regards the first level support of the VAS 6150.
In the currently valid version of this document, please follow the instructions for the VAS
5052A.
You will find this manual on the Basis CD.
2.4
Self-diagnosis manual
2.5
2.6
2.7
Utility CD
The utility CD is used in connection with the VAS 6150 for the installation of the "certificates"
and for "the ELSA recovery and restoration".
A CD reference sheet in printed form is enclosed with the Utility CD.
5 - 16
VAS 6150 Basis CD 16 V2.00 onwards
2.8
These instructions are included with the respective Basis CD in printed form and briefly
describe the Basis CD installation.
2.9
6 - 16
VAS 6150 starting with Basic CD 16 V2.00
3.
System recovery
3.1
General
The VAS 6150 (Panasonic CF-52) possesses a hard disk recovery system.
The system recovery is made using a partition on the hard disk.
You, therefore, do not require any Recovery CD/DVD as was the case with the previously
known VAS 505x systems.
The provided CDs (Windows XP or Windows Vista) cannot be used in connection with the
VAS 6150!
These CD/DVDs are intended for the standard use of the laptop. For a subsequent use, the VAS 6150 must be
unlocked by the equipment manufacturer.
The hard disk partition "D" remains unaffected during the system recovery, i.e. the data
stored on this partition is preserved.
To start the system recovery, please take the following steps in this chapter.
We recommend that you contact the concerned support for the system
recovery.
Tip
Should the recovery system on the hard disk be corrupted and thus no
system recovery be possible, please contact the concerned support.
Tip
During the installation of the Basis CD you will require the device number, the importer
number and the company registration number.
In VAS-PC, the selection is done using the "Administration" button. The numbers are
displayed in the right information window.
7 - 16
VAS 6150 Basis CD 16 V2.00 onwards
Tip
Before beginning the system recovery, connect the VAS 6150 to the mains using the
power supply.
The VAS 6150 must not be connected to the docking station (port replicator) during the
system recovery and the subsequent initial startup.
Before you execute a step of the system recovery, go through the instructions
completely and follow them exactly.
3.2
To start the system BIOS (setup), you must first shut down your VAS 6150 and restart.
Panasonic logo will be displayed during the starting procedure.
As soon as "Press F2 for Setup" is displayed in the bottom left corner, please press the
"F2" key.
8 - 16
VAS 6150 starting with Basic CD 16 V2.00
3.3
Please enter the BIOS password and confirm your entry with the "Enter key.
The BIOS password is "VAS6150".
Please type the password accurately.
3.4
Select "Exit" in the BIOS menu by pressing the "Left" arrow key.
Now select "Repair your Computer" using the "down" arrow key and confirm with the
"Enter" key.
9 - 16
VAS 6150 Basis CD 16 V2.00 onwards
3.5
Now press the "2" key as asked and again confirm this input with the Enter key
3.6
3.7
10 - 16
VAS 6150 starting with Basic CD 16 V2.00
During the restart a window appears in which you are requested to set the system
language. Click Next.
In the window which appears now, you still have the option of setting the date and time as
well as the time zone. On clicking Next the system recovery is continued.
Now the various system settings are carried out and Windows is started.
This process takes a few minutes (about 2 minutes).
11 - 16
VAS 6150 Basis CD 16 V2.00 onwards
3.8
To change the language and keyboard settings under Windows, click "Start" and select
"Control Panel" under "Settings.
In the "Control Panel" window, double click "Regional and Language Options
12 - 16
VAS 6150 starting with Basic CD 16 V2.00
Under the "Regional Options tab, select the desired language and your location. Then
click the "Languages" tab.
2
1.
Now, first select the language used in menus and dialogs and then click "Details".
If the keyboard language matching your device configuration is not displayed, click "Add"
and select the appropriate language in the subsequent windows.
13 - 16
VAS 6150 Basis CD 16 V2.00 onwards
Now click the "Advanced" tab and select the desired language in this window as well.
Click OK.
Acknowledge the displayed message with "OK".
In the two windows appearing now, click "Yes".
The VAS 6150 is restarted now with the previously set language.
3.9
For the software installation, please follow the instructions in the available documentation
ID_VAS505xx_GER_V020.PDF, chapter 3
The abbreviation GER stands for the language version and displays the desired
14 - 16
VAS 6150 starting with Basic CD 16 V2.00
language.
You will likewise find the VAS-PC software on the VAS 6150 under
D:\VAS_SW_Backup\Basis_CD15\setupstart
The software installation takes about 5 minutes.
After successful installation, the VAS-PC software must be started once and then closed.
3.10
Run the file "VAS_5055_prep". The file is on the Utility CD V02.00.00 in the folder
"VAS_6150_Config". The software patch cannot be started via the user interface of the
Utility CD.
For further installation instructions, please refer to the CD reference sheet for the Utility
CD V02.00.00.
After successful installation the following window appears:
Tip
3.11
For the start and setup of the Basis CD software, please follow the instructions in the
available documentation ID_VAS505xx_GER_V020.PDF, chapter 4.1.2
The abbreviation GER stands for the language version and displays the desired
language.
Please enter the device number, the importer number and the company registration
number in the VAS-PC software.
Further, the appropriate model CDs have to be installed within the VAS-PC software
(these are a part of the scope of delivery of the VAS 6150).
15 - 16
VAS 6150 Basis CD 16 V2.00 onwards
3.12 Step 11: Connection and configuration of the VAS 5054A remote
diagnosis head or the VAS 5055 diagnostic interface
Before setting up the VAS 5054A remote diagnosis head, please ensure that the
Bluetooth interface in the VAS 6150 is switched on!
For further connection and configuration of the VAS 5054A remote diagnosis head or
the VAS 5055 diagnostic interface, please follow the appropriate chapters of the
device manual "VAS5054A_VAS5055_mit_VAS5052A_VAS6150_GER_V1_11.pdf".
The abbreviation GER stands for the language version and displays the desired
language.