Sie sind auf Seite 1von 17

Form No.

E09005
Rev. B. 09.17.2015

INSTRUCTION MANUAL
TWP SERIES HYDRAULIC TORQUE WRENCH PUMP

01 SAFETY INSTRUCTIONS

Carefully inspect all components for shipping damage. If shipping damage is found, notify the carrier at once.
The carrier is responsible for any damage resulting from shipment.

To avoid personal injury or property damage, please read, understand, and follow all safety instructions.

EAGLE PRO is not responsible for injury or damage resulting from unsafe and/or incorrect product use or
system operation, or lack of proper maintenance.

DANGER! Is used only when your action or lack of action may cause serious injury or death.
WARNING! Is used when a potential danger exists that requires correct action to avoid personal injury.
IMPORTANT! Is used when action of lack of action can cause equipment failure.
WARNING!
One person should operate both the hydraulic pump and the hydraulic torque wrench, unless there is
clear and unobstructed communication between the two operators. Do not place hands near action or
reaction points.

IMPORTANT!
To avoid personal injury or property damage, please read, understand, and follow all safety instructions.
Always keep work area clean and free of clutter.
When not in use, tools should be properly stored to avoid damage .
Operator must wear proper safety attire when working with hydraulic equipment. Work gloves, safety

glasses, hard hats, approved safety shoes, and hearing protection and/or other required clothing should be
worn while operating this equipment.

DANGER!
The hydraulic equipment user must be a qualified operator with correct training and work experience with

hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal
injury.
Carefully inspect hydraulic pump before using . If any damage is found, discontinue use and contact your

closest authorized EAGLE PRO Service Center.


To avoid personal injury, do not modify or weld hydraulic equipment without approval of EAGLE PRO

INDUSTRIAL TOOLS, INC.


All EAGLE PRO torque wrenches are designed for a maximum of 10,000 PSI/700 bar. Do not connect

torque wrenches to a pump with a higher pressure rating or equipment damage may occur.
EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.


Use high quality impact sockets that are in good condition with the hydraulic torque wrench. Ensure they

are the correct size and engage the hex portion of the bolt/nut correctly. Unseen flaws or damage to the
impact sockets could cause failures during use. Remain clear of impact sockets during application.
Do not hammer on hydraulic torque wrench, pump or socket to enhance performance. If the bolt/nut will

not rotate, select a larger torque wrench for the application.


Do not pick up the torque wrench by the hydraulic hose or swivel.
Do not pick up the hydraulic pump by the power cord, pendant control cord, or hydraulic hose.
Electrical pumps should never be used in a potentially explosive environment.
Ensure that the pump is properly grounded to guard against electrical shock.
Do not use kinked or damaged hydraulic hoses.
Carefully inspect the hydraulic couplers on pump, hoses, and torque wrenches before using. Never

connect tools with damaged couplers or damaged port threads. The damaged coupler(s) or damaged port
threads may cause equipment failure and possible personal injury.
Install couplers in a clean environment. Always prevent dirt or other debris from entering into the

cylinder. Dirt or debris will damage the tool and result in equipment failure and possible personal injury.
Before removing or tightening hose(s) or coupler(s), always release hydraulic pressure in system .
Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious

injury. Seek medical aid immediately if injured.


When the pump is not in use, release the valve, remove the hoses and use the dust cap to recover the port.
Do not drop anything on hydraulic hoses.
Fully retract the hydraulic torque wrench before adding fluid to the torque wrench pump. Failure to do so

will result in excess reservoir pressure and could cause personal injury.
Do not use equipment in temperatures of 150F (65C) or higher. Overheating will soften seals and

weakens hose materials, resulting in oil leaks or other equipment failure.


For hydraulic technical help or repair service, please contact the closet authorized EAGLE PRO Service

Center. EAGLE PRO INDUSTRIAL TOOLS, INC. has no obligations under any warranty with respect
to products that have been repaired by unauthorized personnel, modified, or damaged through misuse,
abuse, accident, neglect, or mishandling.

DANGER!

REACTION POINT SAFETY


Adjust reaction arm in the same direction as the square drive when possible. Avoid excessive play.
Do not hold torque wrench during operation. If the torque wrench must be held or steadied during

operation, use alternative means of securing tool to the application.


Always ensure that all body parts and clothing are clear of the reaction arm and reaction surface during

use.
EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

02 INITIAL SETUP INSTRUCTIONS


Visually inspect the pump for any shipping damage. If any damage is found, notify the carrier immediately.
Carrier is responsible for any damage that occurs during shipment.
Remove the pump from the shipping carton and fill the reservoir with the provided
hydraulic fluid. First, remove the reservoir plug, see FIG A. Rotate the plug
(black knurled knob) counter clockwise to loosen. Fill reservoir with supplied
fluid and tighten by rotating fill knob clockwise. Fill plug needs only to be hand
tight. Prior to any use, loosen the brass reservoir vent plug. Ensure this plug is
tightened once work is completed, or fluid may leak from this opening.

VentPlug

FillPlug

FIG A

2.1

ELECTRICAL CONNECTIONS

Ensure proper power availability to prevent motor failure or dangerous overloading. Use the recommended
amperage listed on the motor nameplate. Do not use the electric pump if the ground is not connected on the
power plug.
Always minimize the length of extension cords and be sure they are of adequate wire size, with proper ground
connections. See FIG B. below for potential impact of using longer extension cords. EAGLE PRO always
recommends a #10 gauge extension cord with a length of no more than 25 feet.

Cord
Length,
Feet
10
20
30
40
50
100

1.3HP 15A 115V MOTOR (% drop from 120V in pare nthe se s)


Extension Cord Wire Gauge
#14 GAUGE
#12 GAUGE
#10 GAUGE
0.9V (0.8%)
0.6V (0.5%)
0.4V (0.3%)
1.8V (1.5%)
1.1V (0.9%)
0.7V (0.6%)
2.7V (2.3%)
1.7V (1.4%)
1.1V (0.9%)
3.6V (3.0%)
2.3V (1.9%)
1.4V (1.2%)
4.6V (3.8%)
2.9V (2.4%)
1.8V (1.5%)
9.1V (7.6%)
5.7V (4.8%)
3.6V (3.0%)

FIG B

WARNING!
Do not operate in a potentially explosive environment, as electric motors may produce sparks.
EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

2.2

HYDRAULIC CONNECTIONS

The EAGLE PRO TWP Series torque wrench pump is equipped with an electronic solenoid pressure relief
valve. Before disassembling hydraulic torque wrench system for storage, transport or maintenance, always
release system pressure. Once work is completed, push the button on top of the
solenoid valve. See FIG C. Before disassembling hydraulic torque system, double
check pressure gauge located on pump to ensure system pressure has been released.
Once system pressure has been released, it is safe to disassemble hydraulic torque
system.
The pumps maximum working pressure is 10,000 PSI (700 bar) . Ensure that all
hydraulic equipment used with this tool are rated for 10,000 PSI (700 bar) working
pressure.

FIG C

WARNING!
Improperly connected hydraulic couplers can be dangerous if pressurized. Do not
grab, touch or come in contact with a pressurized hydraulic fluid leak. Escaping
fluid can penetrate the skin and cause severe injury.

03 OPERATION INSTRUCTIONS
3.1 ASSEMBLING THE SYSTEM
The EAGLE PRO TWP Series torque wrench pump is connected to various EAGLE PRO torque wrench
heads with a dual, high strength thermo-plastic hydraulic hose assembly complete with hydraulic couplers and
protective dust covers.
Attach the hose assembly to the pump valve (top male and female outlets) by pushing the male coupler fully
into the female coupler. (See FIG D and FIG E).

MaleCoupler

FemaleCoupler

FIG D

EAGLEPROINDUSTRIALTOOLS,INC.

FIG E

FORMNO.E09005REV.A.

While pushing the male coupler into the female coupler, rotate the locking collar on the female coupler so that
it screws onto the male collar. Ensure that the locking collar is firmly attached to the male coupler, when
properly tightened, the locking teeth on the collar will engage to prevent the coupler from coming loose. The
locking collar should only be hand tightened. See FIG F below.

Properlyseatedmale
andfemalecouplers

FIG F

IMPORTANT!

Ensure hydraulic connectors are fully engaged. Connectors not properly seated can leak and cause system
malfunctions.

EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

3.2

ATTACHING PUMP TO TORQUE WRENCH HEADS

See the operators manual for your specific EAGLE PRO hydraulic torque wrench for detailed instructions on
assembling and setting up an EAGLE PRO hydraulic torque wrench.
Attach the dual, thermo-plastic hose to the torque wrench head. Ensure that both the male and female couplers
are properly seated. See FIG I.

Properlyseatedmale
andfemalecouplers
onTorquewrenchhead

FIG I

3.3

SETTING SYSTEM PRESSURE/REQUIRED TORQUE

Once the torque wrench pump and torque wrench are properly assembled and connected, and the hydraulic
pump has a proper power supply, the pressure on the pump must be set. The amount of pressure the pump
provides ultimately dictates the amount of torque the torque wrench can produce.

Torque sequence may vary from location to location and it may even vary within a single location. There
are many variables that must be understood to achieve proper torque. Always abide by local procedures,
regulations and ASME PCC-1-2013 standards.

Each EAGLE PRO torque wrench is supplied with a pressure-torque conversion chart. See FIG J for an
example of the ESW torque wrench pressure-torque conversion chart.

EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

ESWSERIESTORQUEWRENCHES
MODEL

ESW1

ESW3

ESW5

ESW8

ESW10

ESW20

PSI

FT.LBS

FT.LBS

FT.LBS

FT.LBS

FT.LBS

FT.LBS

1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
5200
6400
6600
6800
7000
7200
7400
7600
7800
8000
8200
8400
8600
8800
9000
9200
9400
9600
9800
10000

134
161
188
215
242
268
295
322
349
376
403
430
457
483
510
537
564
591
618
645
672
698
725
752
779
806
833
860
887
914
940
967
994
1021
1048
1075
1102
1129
1155
1182
1209
1236
1263
1290
1317
1344

328
394
459
525
590
656
721
787
852
918
984
1049
1115
1180
1246
1311
1377
1443
1508
1574
1639
1705
1770
1836
1901
1967
2033
2098
2164
2229
2295
2360
2426
2491
2557
2623
2688
2754
2819
2885
2950
3016
3082
3147
3213
3278

547
656
766
875
985
1094
1203
1313
1422
1532
1641
1750
1860
1969
2079
2188
2297
2407
2516
2626
2735
2844
2954
3063
3173
3282
3391
3501
3610
3720
3829
3938
4048
4157
4267
4376
4485
4595
4704
4814
4923
5032
5142
5251
5361
5470

783
940
1096
1253
1409
1566
1723
1879
2036
2193
2349
2506
2662
2819
2976
3132
3289
3446
3602
3759
3915
4072
4229
4385
4542
4699
4855
5012
5168
5325
5482
5638
5795
5951
6108
6265
6421
6578
6735
6891
7048
7204
7361
7518
7674
7831

1127
1352
1578
1803
2029
2254
2480
2705
2931
3156
3381
3607
3832
4058
4283
4509
4734
4959
5185
5410
5636
5861
6087
6312
6538
6763
6988
7214
7439
7665
7890
8116
8341
8567
8792
9017
9243
9468
9694
9919
10145
10370
10595
10821
11046
11272

1937
2324
2712
3099
3487
3874
4261
4649
5036
5424
5811
6198
6586
6973
7361
7748
8135
8523
8910
9298
9685
10072
10460
10847
11235
11622
12009
12397
12784
13172
13559
13946
14334
14721
15109
15496
15883
16271
16658
17046
17433
17820
18208
18595
18983
19370

FIG J

EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

Below is an example of how to properly use the ESW Torque Wrench pressure-torque chart..

EXAMPLE
Application requires use of an ESW-3 EAGLE PRO hydraulic torque wrench to tighten a 1-1/2 bolt to 2100
Lb. Ft.
STEP 1. Locate the correct model of the torque wrench along the top of the pressure-torque chart
STEP 2. Read straight down the column until you find the closest figure to 2100. In this application it would
be 2164. 2164 is about 3% over the required torque value for this application.
STEP 3. From the figure of 2164, read all the way over to the left hand column of the chart, this will tell you
what pressure the pump must product to reach this torque value. In this case, to reach 2164 lb. ft. of torque
with the ESW-3 torque wrench, the torque wrench pump must product 6600 PSI.
As 2164 lb. ft. of torque is within the +/-3% accuracy range of the ESW-3 torque wrench, you could
leave the pressure at 6600 PSI. For higher precision, you should reduce the 6600 PSI by 3% to 6402
PSI.

3.4

SETTING PUMP PRESSURE

Now that pump pressure has been determined, follow the procedure below to set the pump pressure.
STEP 1. Loosen the lock ring on the T handle of the external pressure valve. Turn the T handle counter
clockwise until it moves easily.
STEP 2. Turn the pump on. Using the pendant control, push down on the
ADVANCE button and hold it.

THandle

STEP 3. While continuing to hold the ADVANCE button down,


slowly turn the T handle clockwise and watch the pressure rise on the pump
pressure gauge.
STEP 4. When the gauge reaches the required pressure (see example above to
determine required pressure) stop turning the T handle and allow the pressure
to stabilize.
STEP 5. If the pressure continues to rise above required pressure, release the
ADVANCE button and turn the T handle counter clockwise, this will reduce
system pressure. Press the ADVANCE button again and slowly bring the pressure up to the required pressure.
STEP 6. Once the pressure is correct, turn the pump off. Tighten the lock ring on the T
handle against the valve body. This will lock the T handle in place and prevent pressure
changes. This sets the pump pressure which ultimately determines the torque output of the torque wrench.
Cycle the pump one final time to ensure that the pressure is properly set.

IMPORTANT!
Do not adjust the pump pressure while the torque wrench is operating. Adjust the regulator so that the pressure
is increasing, not decreasing. If you have to lower pump pressure, start the pressure setting procedure from the
beginning.
EAGLEPROINDUSTRIALTOOLS,INC.

FORMNO.E09005REV.A.

3.5

PUMP OPERATION TIGHTENING

See the operators manual for your specific EAGLE PRO hydraulic torque wrench for detailed instructions on
assembling and setting up an EAGLE PRO hydraulic torque wrench.
With the EAGLE PRO torque wrench properly assembled and properly positioned on the work piece, follow
the procedure below.

STEP 1. Push down on the ADVANCE button of the pump pendant control. This will push the rear of the
tool backwards until the reaction arm comes into contact with the chosen reaction point. ENSURE ALL
BODY PARTS AND CLOTHING ARE FREE OF THIS AREA .
STEP 2. Hold down the ADVANCE button on the pendant control as the torque wrench continues to
operate. You will hear an audible CLICK once the torque wrench has reached its full extension.
If you continue to hold down the ADVANCE button at this point, the pump will continue to build
pressure to the preset pressure that was set earlier. This does not indicate that the proper torque has
been applied to the bolt/nut. It only indicates that the cylinder is extended and is unable to rotate
further until the torque wrench resets.
STEP 3. Release the ADVANCE button after hearing the audible CLICK. This will reset the torque
wrench. Once the torque wrench is reset, you will hear another audible CLICK. Each time the torque
wrench is advanced and reset in this manner is considered a CYCLE. In order to obtain the proper amount of
torque on the fastener, several CYCLES may need to be made until the tool stalls at the pre-set pressure/
torque. Always cycle the torque wrench one final time to make sure the stall point has been reached.
LOCK ON
Should the torque wrench lock-on during operation, push down on the ADVANCE button to build pressure.
Continue to hold the ADVANCE button down and push the drive release lever down. Release the
ADVANCE button while continuing to hold the drive release lever down. This will allow the torque wrench
to be removed.

3.6

PUMP OPERATION LOOSENING

Following the procedure in section 3.4 set the pump pressure to 9,000 PSI . Do not try to loosen bolt/nut
with pump set at full 10,000 PSI. Change the torque wrench to the loosening mode and properly position on
work piece.
Press and hold the ADVANCE button on the pendant control. Pump pressure will decrease as the bolt/nut is
loosened. Once the cylinder is fully extended you will hear an audible CLICK. Release the ADVANCE
button and the torque wrench will reset. Once the torque wrench is reset, you will hear an audible CLICK.
Continue to CYCLE the torque wrench until you can remove the fastener by hand.

IMPORTANT!
If the fastener does not loosen with the above procedure, you must select a larger torque wrench to remove
the fastener.
EAGLEPROINDUSTRIALTOOLS,INC.

10

FORMNO.E09005REV.A.

04 MAINTENANCE
IMPORTANT!

In order to ensure proper operation of the electric pump, completely drain and clean the pump reservoir every
250 hours, or more frequently if used in dirty environments. In general hydraulic fluid should be a light
yellow and transparent liquid. If hydraulic fluid appears dark or cloudy replace the fluid.

4.1

CHANGING THE HYDRAULIC FLUID

Follow the steps below to change the hydraulic fluid.


STEP 1. Ensure pump is unplugged from power source and system pressure has been released.
STEP 2. Unscrew and remove the reservoir oil fill plug.
STEP 3. Loosen reservoir drain plug using a 6mm hex wrench. See FIG K
Drain oil into approved container and dispose of properly according to local regulations.
STEP 5. Loosen the (4) 5mm hex socket bolts holding the roll cage to
the pump reservoir. Remove pump from roll cage
STEP 4. Unscrew and remove the (6 ) 5mm hex socket bolts holding
the reservoir to the top plate of the hydraulic pump.
STEP 5. Lift the top plate off of the pump reservoir, being careful not
to damage the pump body and set aside.
ReservoirOilDrainPlug

STEP 6. Clean the pump reservoir with a mild cleaning agent and
wipe dry. Ensure that any small pieces of paper towel or rag
are removed from the reservoir.

FIG K

STEP 7. Unscrew the oil filter by hand from the pump body and clean
using a mild cleaning agent and a soft brush. Flush the filter with clean hydraulic fluid to ensure any
cleaning agents and/or small particles have been removed from the filter. If the oil filter is damaged
contact the nearest authorized Eagle Pro service center to order a replacement.
STEP 8. Screw oil filter back onto pump body, be sure to only hand tighten oil filter. Over tightening may
damage the pump body.
STEP 9. Reassemble pump and reservoir and place back into roll cage, and secure assembled pump to roll
cage.
STEP 10. Once pump is completely assembled, add new, clean ISO #32 hydraulic fluid, see Section 02
Initial Setup Instruction's on how to add hydraulic fluid.
EAGLEPROINDUSTRIALTOOLS,INC.

11

FORMNO.E09005REV.A.

05

Torque Wrench Pump Troubleshooting

Solution
1.Inspectthepowerensureyouareusingpropergaugeextensioncord
1.FaultCondition
Pumpwillnotstart
2.TurnonthePowerSwitch
2.PowerSwitchNotTurnedOn
1.Addhydraulicfluid
Pumpwillnot 1.Lowhydraulicfluidlevel
2.Inspectallconnections,checkcouplersandreplaceanydamageditems
deliverhydraulic 2.Leakingconnection
oil,ordeliversless 3.Dirt/debrisinpump,filterclogged
3.Changehydraulicfluid
thanratedflow 4.Reliefvalvesettoolow
4.ContactyourlocalAuthorizedEagleProServiceCenter
rates,ordelivers 5.Directionalvalvefailure
5.ContactyourlocalAuthorizedEagleProServiceCenter
6.Powersupplyvoltagetoolow
erratically.
6.Inspectthepowerensureyouareusingpropergaugeextensioncord
Pumpbuildsfull 1.Loadgreaterthantorquewrenchcapacityatfullpressure 1.Replacetorquewrenchwithlargercapacityunit.
pressure,torque 2.Couplersnotcorrectlyassembled
2.Inspectallconnections,checkcouplersandreplaceanydamageditems
1.Replacethecoupler(s)
Couplerleaking 1.Couplerfailure
Systempressure 1.Highpressurevalvesettoolow
1.ContactyourlocalAuthorizedEagleProServiceCenter
doesnotreach 2.Highpressurevalvefailure
2.ContactyourlocalAuthorizedEagleProServiceCenter
ratedpressure 3.Directionalvalvefailure
3.ContactyourlocalAuthorizedEagleProServiceCenter
Torquewrench
cylinderwillnot 1.Hydraulicconnectionsarenotconnectedproperly
1.Inspectallconnections,checkcouplersandreplaceanydamageditems
retract
Torquewrench
1.Inspectallconnections,checkcouplersandreplaceanydamageditems
1.Hydraulicconnectionsarenotconnectedproperly
safetyvalve
releasingoil 2.Couplerfailure
2Replacecoupler(s)
Motorshutsoff
1.Motortemperatureistoohigh
1.Allowmotortocooltonormaloperatingtemperature
1.Oncehydraulicfluidreaches86F,systemwillturnonautomatically
Oilcoolingsystem 1.Oiltemperaturehasnotreached86F
2.ContactyourlocalAuthorizedEagleProServiceCenter
notcooling 2.Temperaturesensorfailure
3.ContactyourlocalAuthorizedEagleProServiceCenter
hydraulicfluid 3.Dirt/debrisincoolingsystem
1.Checkallelectricalconnectionsandensureyouareusingpropergauge
1.Incorrectelectricalconnections
extensioncord
Motorrunshot
2.Stopusingpumpandallowmotortocooltonormaloperatingtemperature
2.Pumprunningtoolong
3.Workingenvironmentistoohotforpump
3.Donotusepumpinextremelyhotenvironments
Problem

PossibleCause

EAGLEPROINDUSTRIALTOOLS,INC.

12

FORMNO.E09005REV.A.

TWP-2AF TORQUE WRENCH PUMP

EAGLEPROINDUSTRIALTOOLS,INC.

13

FORMNO.E09005REV.A.

EAGLEPROINDUSTRIALTOOLS,INC.

14

FORMNO.E09005REV.A.

EAGLEPROINDUSTRIALTOOLS,INC.

15

FORMNO.E09005REV.A.

EAGLEPROINDUSTRIALTOOLS,INC.

16

FORMNO.E09005REV.A.

EAGLEPROINDUSTRIALTOOLS,INC.

17

FORMNO.E09005REV.A.

Das könnte Ihnen auch gefallen