DC221-03E
1. Point type
Analog
input
ID
0
1
AI
Analog
input
2
Analog
output
1
AO3
Analog
output
AO4
Analog
output
(SCP)
Running
monitoring
(OOAm)
ON-OFF
-AUT
OOAt
ON-OFF
-AUT
4 to 20mA
(Local command)
Digital input
2
SOP
Status
AOP
Alarm
SAP
Status
+Alarm
M/M
Digital input/output
Momentary
Maintained Transfer
3
4
5
COPm
COPl
S/S
S/S
(Momentary)
(Maintained)
CCPm
S/S+Status
CCPl
S/S+Status
(Momentary)
(Maintained)
CAPm
S/S+Status
+Alarm
CAPl
S/S+Status
+Alarm
(Momentary)
(Maintained)
(Momentary)
(Transfer)
AO5
Analog
output
HOLm
HI-OFF
-LO
HOLt
HI-OFF
-LO
(Voltage)
(Momentary)
(Transfer)
Totalizer
6
TTD
Pulse
TOT
TTA
Analog
TOT
CCPf
S/S+Status
(Momentary remote)
CAPf
S/S+Status
+Alarm
(Momentary remote)
HOLf
HI-OFF
-LO
(Momentary remote)
Note:
1. The point type ID number is a 2-digit number. Ex. AI: 01, CCPl: 42
2. The following point types are not available for Infilex GC/GD.
Point type: SCP, OOAm
3. If the point has no input/output, such as analog parameter, set pseudo (1).
Para
meter
7
PRD
Digital
parameter
PRA
Analog
parameter
Note:
Refer to the document, DC221-01E page 36
COS alarm: Only status changes, although ON/OFF point where receives no command.
Command fail: Status does not change, after ON/OFF point where receives the start and stop
command.
Period monitoring time inhibit command fail (default 2 seconds)
XXXf (momentary remote): detect command fail, not detect COS alarm
Parameter
Totalizer
Status
CCPl
CCPm or CCPf
Alarm
Output
Name
Point type
Analog
CAPl
O
CAPm or CAPf
O
O
O
SOP
SAP
O
O
AOP
O
AI
O
TTD
O
AO6
COPl (Usage: point interphone) (DIF-II only)
Symbol
Description
M:
Maintained/Latched output, 1a
C:
A:
Name displayed
Item name
SOP
SAP
SCP
AOP
COP
mlt
CCP
ml
CAP
mlf
OOA
mlt
HOL
mlt
CCPt
TYPE
Point type
A/D
A/D
IPD
IPD
SEG
Segregation
ABL
Rated power
DLAYs
On delay time
TIMEs
NRCV
DI1
I/O DI1
DI2
I/O DI2
DO1
I/O DO1
REC
LOG1
OI Command/COS log
(Not in use.)
Boolean calculation 1
LOG2
Boolean calculation 2
VLV
Switch valve
BCNT
NC contact changeover
TIMs
AI
AO3
AO4/5
TTD
TTA
PRD
PRA
TYPE
Name displayed
Point type
Item name
A/D
A/D
IPD
IPD
SEG
Segregation
DPOS
Decimal position
COEF
Coefficient
SCL
Prescale range
RTIO
Sampling ratio
MAXS
High limit
MINS
Low limit
MAX
MIN
FLG
Output
AIS
ZERO
Zero adjustment
FBC
Name displayed
Item name
AI
AO3
AO4/5
TTD
TTA
PRD
PRA
FBO
GAP
Gap
HYS
Hysteresis
CLMP
Clamp delete/assign
AOCYs
COV
COV
RNG
HYC
AI1
Measuring cycle
Normal/increased interval
I/O
AO1
I/O
TO1
I/O
AIP
Note:
When the point is a central monitoring point, not write anything in the column of Central. And set SEG=
10000000.
When the point is not a central monitoring point, write [X] in the column of Central. And set SEG=
00000000.
Operation type
Description
OOAt, HOLt
Non-voltage SPDT
CCPf, CAPf
16, 814, 18
X
7
X
15
Y
16
Y
17
Table
00
0.000
0.000
37.002
7.824
-500
25.431
-200
01
0.000
10.002
100
39.878
50
16.651
-350
31.226
-100
02
0.000
20.000
200
42.754
100
25.413
-200
37.002
03
0.000
30.002
300
45.627
150
34.106
-50
42.754
100
04
0.000
40.000
400
48.480
200
42.754
100
48.480
200
05
0.000
50.002
500
51.333
250
51.333
250
54.183
300
06
0.000
60.000
600
54.183
300
59.863
400
59.863
400
07
0.000
70.002
700
57.032
350
68.327
550
65.520
500
08
0.000
80.000
800
59.863
400
76.746
700
71.139
600
09
0.000
90.002
900
62.693
450
85.085
850
76.746
700
10
0.000
100.00
1000
65.520
500
93.389
1000
82.319
800
Application
Reserve
Linear
Pt 100
Pt 100
Pt 100
Range
0.0 ~ 100.0
0.0 ~ 50.0
-50.0 ~ 100.0
-20.0 ~ 80.0
Unit
Linearization
19
Table No.
Linearization
20
21
22
23
24
Table
00
0.000
37.002
20.561
-30
20.561
150
25.413
-200
0.000
01
10.002
10
42.754
100
79.439
30
79.439
300
23.312
-150
15.258
500
02
20.000
20
48.480
200
0.000
0.000
31.226
-100
0.000
03
30.002
30
54.183
300
0.000
0.000
34.106
-50
0.000
04
40.000
40
59.863
400
0.000
0.000
37.002
0.000
05
50.002
50
65.520
500
0.000
0.000
39.878
50
0.000
06
60.000
60
71.139
600
0.000
0.000
42.754
100
0.000
07
70.002
70
76.746
700
0.000
0.000
45.627
150
0.000
08
80.000
80
82.319
800
0.000
0.000
48.480
200
0.000
09
90.002
90
87.866
900
0.000
0.000
51.333
250
0.000
10
100.00
100
93.389
1000
0.000
0.000
54.183
300
0.000
Inside Neopanel,
Application
Humidity (Linear)
Pt 100
Relative Value
Absolute Value
Neoplate
Neoplate
inside wireless
Pt 100
Neopanel, Wireless
sensors
(Temperature)
Ranges
0 ~ 100
0.0 ~ 100.0
-3.0 ~ 3.0
15.0 ~ 30.0
-20.0 ~ 30.0
0.0 ~ 50.0
Unit
Note: Set the number of Linearization Table in the column of AIS No for each AI point.
Linearization
25
Table No.
Linearization
26
27~99
Table
00
0.000
0.000
0.000
01
3.052
100
7.782
255
0.000
02
0.000
0.000
0.000
03
0.000
0.000
0.000
04
0.000
0.000
0.000
05
0.000
0.000
0.000
06
0.000
0.000
0.000
07
0.000
0.000
0.000
08
0.000
0.000
0.000
09
0.000
0.000
0.000
10
0.000
0.000
0.000
Buttery Shortage
Application
Humidity (Linear)
Ranges
0 ~ 100
0.0 ~ 255.0
Unit
For JOB
Notice
7. Signal type
Point type
AI
Input symbol
PT
Description
PT100ohms 0-50 C
RY5004P0000
RY5004J0000 (AIx2, PTx2)
PT100ohms 0-100 C
PT100ohms -20-80 C
PT100ohms -20-30 C
PT100ohms -50-100 C
AIA
AIV1
AIV2
AIV4
RY5004A0000
RY5004J0000 (AIx2, PTx2)
AIV5
AO3
MM
AO4
AOA
AO5
AOV1
AOV2
AOV3
AOV4
Note: Set the input symbol in the column of Signal Type for each AI/AO point.
4~20 mA
0~5 V
1~5 V
0~10 V
2~10 V
11
0~50 (C)
12
0~100 (C)
13
-20~30 (C)
14
-20~80 (C)
16
-50~100 (C)
None
Note: Set the value of parameter in the column of RNG for each AI point.
Connection to
Infilex AC
Model number
Description
RY50
DI
No
DO
No
DO+DI
Yes*5,*7
DOC
No
RRD
No
TOT
No
08 S
0000
16 S
0000
08 D
0000
16 D
0000
16 R
0000
08 C
04 Y
0000
04 T
0000
16 T
0000
02 M
0000
04 M
0000
04 A
0000
04 P
0000
04 J
0000
01 F
0000
03 F
0000
01 U
01 Q
0000
Combination of modules
input points +
(For voltage/current input, see AI. For
2 temperature input points
temperature input, see Pt.)
I/O module for 1 Modutrol Motor Output is limited to AO3.
output point
Input (measurement of actual opening)
MM
3
I/O module for 3 Modutrol Motor 1 point*
is limited to AI.
output points
Operator Panel
(integral type)
Yes*6,*7
AO
No
AI
No
Pt
No
AI+Pt
Yes*7
MM
No
UT
Yes
OP
Yes
Notes:
1 Since the DO module does not have any N.C. (normally close) contact, the DOC module is used for the OOA or
HOL.
2 In the OOA transfer, ON/OFF is assigned to the first N.O./N.C. contact, and AUTO is assigned to the second
N.O./N.C. contact.
In the HOL transfer, HI/OFF is assigned to the first N.O./N.C. contact, and LO is assigned to N.O. of the second
N.O./N.C. contact.
3 Two points, AO3 and AI, are assigned to one MM point in the point file.
The following shows the points correnponsing to IO numbers.
IO number
Point type
MM1:
(1, 2)
(AO3, AI)
MM2:
(3, 4)
(AO3, AI)
MM3:
(5, 6)
(AO3, AI)
4 For the HOL momentary/local, 3 points of N.O./N.C. contact DO of the DOC module are required.
HI: N.O. contact of DO, OFF: NC contact of DO2, and LO: NO contact of DO3
5 For DO+DI module connected to Infilex AC (Model WY5117C1400), I/O points are limited to DI 4 points and DO 4
points.
6 For AO module connected to Infilex AC (Model WY5117C1400), voltage output (0-5 V, 0-10 V, 1-5 V, 2-10 V) is
only available.
7 For DO+DI module, AO module, and AI+Pt module, connectabe Infilex AC is Model WY5117C1400 only.
10
Module ID = 1
Module ID = 2
Module ID = 3
Module ID = 4
Module ID = 5
DI 8
DI 16
DO 8
DO 16
DIO
I/O No.
Termial No.
I/O No.
Termial No.
I/O No.
Termial No.
I/O No.
Termial No.
Termial No.
DI 1
DI 1
DO 1
DO 1
DO 1
DI 2
DI 2
DO 2
DO 2
DO 2
DI 3
DI 3
DO 3
DO 3
DO 3
DI 4
DI 4
DO 4
DO 4
DO 4
DI 5
DI 5
DO 5
DO 5
DO 5
DI 6
DI 6
DO 6
DO 6
DO 6
DI 7
DI 7
DO 7
DO 7
DO 7
DI 8
DI 8
DO 8
DO 8
DO 8
I/O No.
1
COM
COM
COM
COM
DO COM
COM
10
COM
10
COM
10
COM
10
DO COM
10
DI 9
11
DO 9
11
DI 1
11
10
DI 10
12
10
DO 10
12
10
DI 2
12
11
DI 11
13
11
DO 11
13
11
DI 3
13
12
DI 12
14
12
DO 12
14
12
DI 4
14
13
DI 13
15
13
DO 13
15
13
DI 5
15
14
DI 14
16
14
DO 14
16
14
DI 6
16
15
DI 15
17
15
DO 15
17
15
DI 7
17
16
DI 16
18
16
DO 16
18
16
DI 8
18
COM
19
COM
19
DI COM
19
COM
20
COM
20
DI COM
20
11
Module ID = 6
Module ID = 7
Module ID = 8
Module ID = 9
DOC 8
RRD 4
TOT 4
TOT 16
I/O No.
COM 1
RRD 1 (White)
DO 1b
(Virtual DI 1)
DO 2a
RRD 2 (Red)
COM 2
RRD 2 (White)
DO 2b
(Virtual DI 2)
TOT 1
Termial No.
Termial No.
RRD 1 (Red)
I/O No.
I/O No.
1
Termial No.
Termial No.
1
I/O No.
DO 1a
TOT 1
TOT 2
TOT 2
TOT 3
TOT 3
TOT 4
TOT 4
NC
TOT 5
NC
TOT 6
DO 3a
RRD 3 (Red)
NC
TOT 7
COM 3
RRD 3 (White)
NC
TOT 8
DO 3b
(Virtual DI 3)
COM
COM
COM
10
COM
10
11
DO 4a
10
10
RRD 4 (Red)
COM 4
11
11
RRD (White)
DO 4b
12
12
(Virtual DI 4)
DO 5a
13
TOT 9
COM 5
14
10
TOT 10
12
DO 5b
15
11
TOT 11
13
DO 6a
16
12
TOT 12
14
COM 6
17
13
TOT 13
15
DO 6b
18
14
TOT 14
16
DO 7a
19
15
TOT 15
17
COM 7
20
16
TOT 16
18
DO 7b
21
COM
19
DO 8a
22
COM
20
COM 8
23
DO 8b
24
12
Module ID = 10
Module ID = 11
Module ID = 12
Module ID = 13
Module ID = 14
AO 2
AO 4
AI 4
Pt 4
AI/Pt
AOI 1 +
AOI 1 -
AOI 1 -
AOV 2 +
AOV 2 +
AOV 2 -
AOV 2 -
AOI 2 +
AOI 2 -
AOI 2 +
AOI 2 -
AOV3 +
AOV3 -
10
AOI3 +
11
AOI3 -
12
AOV4 +
13
AOV4 -
14
AOI4 +
15
AOI4 -
16
13
Pt 1B
Pt 1B
Pt 2A
Pt 2B
AII 1
COM 1
AIV 2
AII 2
COM 2
Pt 2B
AIV 3
Pt 3A
AII 3
COM 3
AIV 4
10
AII 4
11
COM 4
12
Termial No.
AOV 1 1
Pt 1A
I/O No.
Termial No.
AOI 1 +
AIV 1
I/O No.
Termial No.
AOV 1 +
I/O No.
AOV 1 -
Termial No.
I/O No.
Termial No.
I/O No.
1
AOV 1 +
AIV 1
AII 1
COM 1
AIV 2
AII 2
COM 2
Pt 1A
Pt 3B
Pt 3B
Pt 4A
10
Pt 4B
11
Pt 4B
12
Pt 1B
Pt 1B
Pt 2A
10
Pt 2B
11
Pt 2B
12
Module ID = 15
Module ID = 16
MM1
MM3
Termial No.
I/O No.
Termial No.
I/O No.
1
MM1 Close
MM1 Close
MM1 Open
MM1 Open
MM1 COM
MM1 COM
MM1 COM
MM1 COM
MM1 POT G
MM1 POT G
MM1 POT Y
MM1 POT Y
MM1 POT T
MM1 POT T
(Virtual AI 1)
(Virtual AI 1)
MM2 Close
MM2 Open
10
MM2 COM
11
MM2 COM
12
MM2 POT G
13
MM2 POT Y
14
MM2 POT T
15
(Virtual AI 2)
16
MM3 Close
17
MM3 Open
18
MM3 COM
19
MM3 COM
20
MM3 POT G
21
MM3 POT Y
22
MM3 POT T
23
(Virtual AI 3)
24
14
(Pseudo
AI1)
(Pseudo
AI2)
(Pseudo
AI3)
(Pseudo
AI4)
(Pseudo
AI5)
(Pseudo
AI6)
(Pseudo
AI7)
(Pseudo
AI8)
(Pseudo
AI9)
(Pseudo
AI10)
(Pseudo
AI11)
(Pseudo
AI12)
24
21/22
26
24
25
24
25
Reserved
Reserved
Reserved
Reserved
Reserved
Linearization table No. used
No.21: Neoplate fine-adjustment type (-3.0 to 3.0C)
No.22: Neoplate absolute value type (15.0 to 3.0C)
No.24: Neopanel built-in sensor/Neopanel wireless built-in sensor/
Neosensor wireless temperature (0.0 to 50.0C)
No.25: Neosensor wireless humidity (for 0 to 100%)
No.26: For Neosensor wireless/Neopanel wireless battery shortage notice
Point data for battery shortage notice information is as follows:
0: Both transmitters normal
1: Battery shortage notice included for
transmitter address 1
2: Battery shortage notice included for
transmitter address 2
3: Battery shortage notice included for both
transmitters
*1 Neopanel wireless (transmitter address 1) built-in sensor is pseudo AI4.
*2 Neopanel wireless (transmitter address 2) built-in sensor is pseudo AI6.
15
CAPl (maintained/latched)
CAPm (momentary)
16