Sie sind auf Seite 1von 47

Contents

NM1 Series

MCCB

NM7 Series
NM8 Series
NM8-1600

Automatic Transfer Switch Equipment NZ7 Series

NM1

Overview
General Information

New function
Locking Function

Release for Prepaid KWH Meter

NM1

Overview
General Information
Ui: 800V

Uimp: 8kV

Ue: AC50Hz/60Hz; AC220690V;


In: 10A1250A;

Inm: 63A, 125A, 250A, 400A, 630A,


800A, 1250A
Nominal Temperature: +40;
Standard: EN / IEC 60947-2;

Installation: Horizontal / Vertical;


Suitable for isolation;

NM1

New Functions
Locking

NM1

New Functions

Special Release for Prepaid KWH Meter

Used with the IC card prepaid KWH meter.


When there is no balance in the users IC
card, the release will break the MCCB to cut
the circuit, and prevent the breaker from
making again, so that the user cannot use the
power.
Only until the user has recharged the IC card
with a certain amount, the breaker can make
normally again. So this release can save
much more labor and work quantity.

Contents
NM1 Series

MCCB

NM7 Series
NM8 Series
NM8-1600

Automatic Transfer Switch Equipment NZ7 Series

NM7

Overview

Features

General Information

Clamshell Design

Frame Size &

Modular design inner

Rated Current
Electrical
Characteristics

Accessories

accessories, plug-in installation


Diverse wiring method
Recyclable Material

Selection

NM7

Overview

General Information

Ui: 750V

Uimp:8kV

Ue: AC50Hz/60Hz;AC220415V
In: 16A800A
Nominal Temperature: +40
Standard: EN / IEC 60947-2
Installation: Horizontal / Vertical
Suitable for isolation;

NM7

Overview

Frame Size & Rated Current

1620 25 32 40 50 63 80 100 125

100125 160 180 200 225 250


250 315 350 400
400 500 630
500 630 700 800

NM7

Overview

Main technical features


Frame size rated current
Standard

125

250

400

630

800

EN 60947-2 / IEC 60947-2

Breaking Capacity Code

Poles

3,4

3,4

3,4

3,4

3,4

Icu
(kA)

AC380/400/415V

35

25

35

35

50

65

85

35

50

65

85

35

50

65

85

Ics
(kA)

AC380/400/415V

18

13

18

18

25

33

43

18

25

33

43

18

25

33

43

Shunt release, Undervoltage release


Access
ories

Auxiliary contact,
Alarm Contact
Manual operating
mechanism
Motor-driven
operating mechanism

NM7

Overview

Main technical features


Icu (kA)

AC380/400/415V

Ics (kA) AC380/400/415V

90

90

80

80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

S
125

C
250

S H
400

S H
630

S H
800

S
125

C
250

S H
400

S H
630

S H
800

NM7

Features

Clamshell Design

NM7

Features

Modular Design inner accessories, Plug-in Installation

NM7

Features

Diverse wiring method

NM7

Features

Recyclable Material

NM7

Accessory
Accessory

Code

blank

300

Alarm contact

308

Shunt release

310

Auxiliary contact

320

Under-voltage release

330

Shunt release & auxiliary contact

340

Shunt & under-voltage release

350

Two sets of auxiliary contacts

360

Auxiliary contact, under-voltage


release

370

Shunt release, alarm contact

318

auxiliary contact, alarm contact

328

under-voltage release, alarm


contact

338

Shunt release, auxiliary contact,


alarm contact

348

Two sets of auxiliary contacts,


alarm contact

368

auxiliary contact under-voltage


release, alarm contact

378

NM7-125

NM7-250

NM7-400/630

NM7-800

NM7

Selection
NM7 - 250
Model

Breaking Operation
Frame
Size Capacity Code Code

/ 250

/ 3

Rated Current

Poles

3
Release
Type

NM7

125

Blank:

16

225

3P

MCCB

250

manual

20

250

4P

magnetic

400

handle

25

315

630

operating

32

350

Thermo-

P:

40

400

magnetic

Motor-

50

500

driven

63

630

operating

80

700

Z: Manual

100 800

extended

125

rotary

160

handle

180

800

200

10
Accessory Code

2
Application code

00 blank

08 Alarm contact

Blank:

10 Shunt release

20 Auxiliary contact

for power

30 Under-voltage Release

distribution

40 Shunt release & auxiliary contact

2: for motor

50 Shunt release & under-voltage release

protection

60 Two sets of auxiliary contact


70 Auxiliary contact, under-voltage release
18 Shunt release, alarm contact
28 Auxiliary contact, alarm contact
38 under-voltage release, alarm contact
48 Shunt release, auxiliary contact
58 Shunt release, under-voltage release,
alarm contact
68 Two sets of auxiliary contact, alarm
contact
78 Auxiliary contact, under-voltage release,
alarm contact

Contents
NM1 Series

MCCB

NM7 Series
NM8 Series
NM8-1600

Automatic Transfer Switch Equipment NZ7 Series

NM8

Overview
General
Information

Frame Size &


Rated Current
Main technical
features

Features

Accessory

Selection

Modular Design, Compact Structure


High Breaking Capacity, zero flashover
Upper and Lower Down-lead are Available
Complete Range of Accessories
Intelligent, Adjustable Protection
Plenty Patent Rights, Internationally advanced

NM8

Overview

General Information

Ui: 750V

Uimp: 8kV

Ue: AC50Hz/60Hz; AC220690V


In: 16A1250A
Nominal Temperature: +40
Standard: EN / IEC 60947-2
Installation: Horizontal / Vertical
Suitable for Isolation

NM8

Overview

Frame Size & Rated Current


1620 25 32 40 50 63 80 100 125
40 50 63 80 100 125
100 125 160 180 200 225 250
250 315 400
250 315 400 500
250 315 400 500 630
630 700 800
630 700 800 1000 1250

NM8

Overview

Main technical features

Frame Size Rated


Current

125

250

Standard
Breaking Capacity Code
Poles

400/630

800/1250

EN 60947-2 / IEC 60947-2


S

1P2P3P 4P

3,4

1P2P3P 4P

H
3,4

Icu
(kA)

AC380/400/415V

50

70

150

50

70

150

70

100

150

50

70

Ics
(kA)

AC380/400/415V

50

70

150

50

70

150

70

100

150

25

35

Shunt Release,
Under-voltage
Release
Acc
ess
orie
s

Auxiliary, alarm
contact
Manual Operating
Mechanism
Motor-driven
Operating
Mechanism

NM8

Overview

Main technical features


Icu (kA)

AC380/400/415V

Ics (kA) AC380/400/415V

150

150

140

140

130

130

120

120

100

100

70

70

60

60

50

50

30

30

S H
125

S H
250

S H
400

S H
630

S H
125

S H
250

S H
400

S H
630

NM8

Features

Modular Design, Compact Structure

NM8

Features

High Breaking Capacity, Zero Flashover

NM8

Features

Upper and Lower Down-dead are available

NM8

Features

Complete Range of Accessories

NM8

Features

Intelligent, Adjustable Protection

Thermo-magnetic Release
Over-load Protection: Ir=0.8~1.0In
Short-circuit Protection: Ii=5~10In

Electronic Release
Long time delay over-load protection:

Ir=0.4~1.0In
Short time delay short circuit protection:
Isd=1.5~8In
Short-circuit protection: Ii=1.5~12In
N-line protection: Ig=0.5~1In

NM8

Features

Plenty Patent Rights, Internationally advanced

19 National Patent Rights;


12 International Patent Rights

Country

Application No.

Country

Application No.

China

ZL03145501.8

ZA SouthAfrica

ZA200502896

China

ZL01132088.5

PCT

PCT/CN2003/000198

China

ZL01132307.8

IN Indonesia

00583/CHENP/2005

China

ZL02137201.2

BR Brazil

BR2003PI13977

China

ZL03159155.8

RU Russia

RU2005110673

China

200410069595.2

EP Europea

EP20030794755

China

ZL01254485.X

TN Tonisia

SN05.023

China

ZL01254890.1

MA Morocco

MA27471

China

ZL02267161.7

US America

US2005151607

China

ZL03252749.7

JP Japan

JP2005538517T

China

ZL99202035.2

AU

AU2003236075

China

ZL03273116.7

CA

CA2496171

China

200620160705.0

China

200720143458.8

China

ZL00333041.9

China

ZL02314242.1

China

ZL02314241.3

China

200430020764.4

China

200730110184.8

NM8

Accessory
Accessories
Blank
Alarm contact
Shunt release
Auxiliary contact
Under-voltage release
shunt release, auxiliary contact
Shunt, under-voltage release
Two sets of auxiliary contacts
Auxiliary contact, under-voltage
release
Shunt release, alarm contact
Auxiliary, alarm contact
Under-voltage release, alarm
contact
Shunt release, auxiliary contact,
alarm contact
Two sets of auxiliary contacts,
alarm contact
Auxiliary contact, under-voltage
release, alarm contact

NM8-125

NM8-250

NM8-400/630

NM8-800/1250

NM8

Selection
NM8S - 250
Model

Frame
Size

160

Breaking
Ratd Current
Capacity Code

4C

Poles

Application code

Shunt release:

Under-voltage release

power

SM6:AC220V

UM6:AC220V

Distribution

SQ6:AC380V

UQ6:AC380V

SBI:DC24V

used for NM8-125

used for NM8-125

UM5:AC220V

SM5:AC220V

UQ5:AC380V

SQ5:AC380V

used for NM8-

125

162025

(Thermo-

250

324050

magnetic

400

6380100

Type)

630

125160

M: for

NM8S

800

180200

Motor

(Electronic

1250

225250

3: 3 poles
4: 4 poles

Accessory
Code

Blank: for

NM8

1 :1 poles
2: 2 poles

AX

Protection

Type)

315350

SBO:DC24V

250/400/630

MCCB

400500

used for NM8-

NM8S-125/250/400/630

250/400/630

UM7:AC220V

630700
800

NM8S-125/250/400/630UQ7:AC380V
SM7:AC220V

used for NM8(S)-800/1250

SQ7:AC380V

Auxiliary contact

SB2:DC220V

AXused for the entire

SB3:DC110V

series

used for NM8(S)-

Alarm contact

800/1250

ALused for the entire


series.

Contents
NM1 Series

MCCB

NM7 Series
NM8 Series
NM8-1600

Automatic Transfer Switch Equipment NZ7 Series

NM8-1600

Features of NM8-1600
Small body with powerful functions
In = 1600 A

size of fixed type, 3 poles: 268210175

Selectivity Type Icw(1s)=Icu=Ics= 42kA 415V AC


Current Limiting Type

Icu=Ics=120kA

415V AC

Easy Installation
Identical internal and external accessories convenient for easy and reliable installation;
Various modes of connection;

Powerful Function of Electronic Release


Basic protection
Higher protection
Advanced protection

To be launched on the market


before December 2012

Contents
NM1 Series

MCCB

NM7 Series
NM8 Series
NM8-1600

Automatic Transfer Switch Equipment NZ7 Series

NZ7

Overview

Features

Selection

General Information

Compact Structure with Novel Appearance

Frame Size &

Double Locking

Rated Current

Intelligent Control, multi-functions

Main technical feature Visible Interface


Settable Parameters
Modular Design for the Controller

NZ7

Overview

General Information

Ui: 800V

Uimp: 8kV

Ue: AC400V

50Hz

Us: AC230V

50Hz

Ie: 10A630A
Electric class: CB
Standard: IEC 60947-6-1
Installation: Horizontal / Vertical

NZ7

Overview

Frame Size & Rated Current

101620 25 32 40 50 63

1620 25 32 40 50 63 80100

100 125 160 180 200 225

225 250 315 350 400

400500 630

NZ7

Overview

Main technical features


Model

NZ7-63

NZ7-125

NZ7-250

Standard

NZ7-400

NZ7-630

NM1-400

NM1-630

3P/4P

3P/4P

IEC60947-6-1

Executing
breaker

NM1-63

NM1-125

NM1-250

Ue

400V 50Hz

Poles

3P

4P

3P/4P

3P/4P

Breaking
capacity code

Icm kA)

31.5

73.5

73.5

52.5

105

143

52.5

105

143

73.5

110

154

73.5

110

154

Icn kA)

15

35

35

25

50

65

25

50

65

35

50

70

35

50

70

Us

230V 50Hz

Minimum
operating
voltage

Default Value 187V160V~200V, set by the user

Switching
time
Power
consumption
of the
controller

3.2s

3.5s

3.6s

10W

4s

5s

NZ7

Features

Compact Structure with Beautiful Appearance

NZ7

Features

Double Interlocking System: Mechanical & Electric

NZ7

Features

Intelligent Controller Integrated with Multi-functions

Integrated within three


transfer modes

NZ7

Features

Visible Interface

NZ7

Features

Settable Parameters

Three settable transfer modes


settable delay time
settable threshold for voltage fault

NZ7

Features

Modular Design for the Controller

Installed in the cabinet

Installed on the surface


of the cabinet

NZ7

Selection
NZ7 Model

NZ7

125

Frame Size Breaking Capacity Poles


Code
63
125
250
400
630

S
H
R

3P
4P

100

Rated Current

Controller
Structure

Controller
Type

10A~630A

Y:
Integrated
Type

A
Type

THANK YOU

Das könnte Ihnen auch gefallen