Beruflich Dokumente
Kultur Dokumente
Page 2
Contents
Overview ....................................................................................................................................... 3
System Requirements................................................................................................................... 5
Lightyear Installation .................................................................................................................. 7
Installing Lightyear on a Server or Standalone System ............................................................. 7
Registering the Lightyear Software.......................................................................................... 14
Configuring a Workstation....................................................................................................... 17
Installing USB Drivers for the USB Controller....................................................................... 19
Installing Sensor Files ................................................................................................................ 21
Claris i310D Intraoral Camera Installation.24
Lightyear
1-866-946-2431
Revised March 2006 | 2006 Lightyear Technology, Inc. | All Rights Reserved
Page 3
Overview
It is recommended that you read this entire Installation Guide prior to installing and using your
Lightyear digital radiography system.
Changes
Lightyear is continually improving its products and services. We reserve the right to make
changes without prior notice regarding all information, specifications and illustrations contained
in this Guide.
Intended Use
The Lightyear System is intended to be used as an X-ray image capture device for intraoral
dental radiography by a licensed dental professional, in a dental office environment, in place of
traditional dental X-ray film.
Safety Precautions
Be sure to observe all radiation safety codes and procedures when taking X-ray images.
Do not immerse any Lightyear equipment in liquids; if a solid or liquid falls on any
Lightyear system equipment, unplug the equipment immediately and have it checked by
qualified personnel.
Always use a new disposable sensor sheath on the sensor with each new patient.
Do not install Lightyear equipment near heat sources or where it will be in direct
sunlight; also avoid installing near mechanical vibrations or areas where the equipment
can be subject to shock.
Avoid electro-static discharges (ESD).
No Lightyear system components can be autoclaved.
Service and Maintenance
Only qualified people, certified by Lightyear, can service the equipment; unauthorized repairs
may invalidate the warranty. Inspect all cables for damage every 6 months; if damage is found,
do not use the sensor and contact Lightyear immediately.
Cleaning and Infection Control
Always use a new disposable sensor sheath on the sensor with each new patient.
Clean all components as needed or at least annually; by wiping or spraying them with
rubbing alcohol, ethyl alcohol, or glutaraldehyde.
Make sure all cables are disconnected and the computer is off before cleaning; never
spray cleaner onto the display.
Page 4
Page 5
System Requirements
Item
Minimum Required
Recommended
Notes
Computer
System
Operating
Systems
Windows XP Professional, SP 2
Windows XP Home, SP 2
Windows XP Tablet Edition, SP 2
Windows 2003 Small Business Server,
SP 1
Windows 2003 Enterprise, SP 1
Windows 2003 Standard, SP 1
System
Memory
(All Systems)
128 MB
256 MB or higher
Hard Drive
(All Systems)
USB
USB 2.0
USB 2.0
Monitor and
Video Card
Backup
System
Page 6
Item
Minimum Required
Recommended
Notes
Sound Card
Uninterrupted
Power Supply
(UPS)/Surge
Suppressors
Not required.
Strongly recommended.
Intraoral
Camera
(Optional)
Digital
Intraoral
X-ray Sensor
Panoramic
and
Cephalometric
Units
(Optional)
Printer
(Optional)
Network
(Optional)
Wireless 802.11g
Wireless 802.11g
Not Required
Internet
Access
(Optional)
Page 7
Lightyear Installation
Follow the steps below to install the Lightyear system:
1. Install Lightyear Software
2. Install USB Drivers for the USB Controller on each workstation that will capture x-rays.
3. Install Sensor Files on each workstation that will capture x-rays.
4. If you purchased the optional intraoral camera install camera software on each computer
that will capture intraoral images.
Page 8
4. Enter a User Name and Company Name and then click Next.
Page 9
Page 10
5. Specify the folder to install Lightyear. The default is C:\Program Files\Lightyear. Click
Next.
Page 11
8. Accept the defaults for the TransIT Communication Components by clicking Next.
Page 12
Page 13
Page 14
NOTE: Until the program is registered, click I AGREE to continue using Trial Mode.
Page 15
3. Enter the Registration Number that was included with the installation CD. Enter a User
Name, User Company, Email (if available) and User Phone. To register multiple
workstations, check the box for I have additional registration numbers I would like to
user below the Registration Number.
4. With the Internet connection active, select Get Activation Code. If Internet access is
not available, contact Lightyear Customer Support.
5. After the activation code appears, select Done.
6. If I have additional registration numbers I would like to use was checked, the
Additional Registration Numbers window will appear. Select Add New RegNUM.
Page 16
Page 17
Configuring a Workstation
Due to Lightyears unique structure, only one installation of Lightyear is needed on the network.
Once Lightyear has been installed on the network, all computers running 32-bit Windows
operating systems can automatically run the application without performing additional
installations on each computer.
A typical network installation of Lightyear consists of installing the application on a network
server (or other computer that has been chosen to be the Lightyear server). Since the server is a
shared resource with all of the computers on the network, each workstation automatically will
have access to the application. If you have questions please contact Lightyear Support toll free
at 866-946-2431.
To set up Lightyear on a client workstation, perform the following steps on the workstation:
1. Double-click the My Network Places icon on the Desktop and navigate to the shared
folder containing the Lightyear installation on the server computer.
2. Double click the Lightyear.EXE application file to launch the program.
3. Select Preferences.
Page 18
4. Select Create Local Shortcuts. This will place a Lightyear icon on the Desktop.
Additionally, to set up NameGrabber on a client workstation, perform the following steps on the
workstation:
1. Double-click on the My Network Places icon on the Desktop and navigate to the shared
folder containing the Lightyear installation on the server computer.
2. Double click the NameGrabber.EXE application file. This file will have the
NameGrabber icon associated with it.
3. Once the application starts, a prompt will appear asking whether or not NameGrabber
should be started on this computer automatically. Select Yes to automatically start
NameGrabber whenever the computer is started.
Page 19
2. Connect the USB Controller to the computer using the USB Cable.
3. When the Found New Hardware Wizard screen appears, click Next (if this screen does
not appear please contact Lightyear Support for assistance).
Page 20
4. The Wizard will automatically search the computer to locate the drivers for installation.
Wait for the search to complete.
6. Once the Found New Hardware Wizard has completed, click Finish.
Page 21
2. Double click the Lightyear icon on the Desktop to start the program.
3. Select Preferences.
4. Select Sensor.
Page 22
9. Select Apply.
Page 23
Page 24
Page 25
Page 26
6. When Question window appears, plug your Claris i310D camera into your computer.
The Question window will remain until the driver is fully installed you will be asked to
continue and click Yes in step 13.
7. Windows will recognize your camera automatically. Select No, not this time, then
click Next.
8.
When asked for the driver, select Install the software automatically, then click
Next.
Page 27
10. When the Hardware Installation window appears, click Continue Anyway.
13. Now click Yes on the Question window from step 6 to continue.
14. The dialog box will appear, click on the box to continue.
Page 28
Page 29
Page 30
Page 31
21. When the Hardware Installation window appears, click Continue Anyway.
22. When Parallel Port Joystick window appears, close it by clicking the x in the upper right
corner.
Page 32
24. Parallel Port Joystick and Gamepad configuration utility will appear. Click Add.
25. Click the drop down arrow beside Parallel Port and single click Virtual Port. The
parameters should appear as below. Click Add.
26. Select No, not this time when the screen below appears and click Next.
Page 33
Page 34
Page 35
34. Restarting Windows window will appear. Select Yes, I want to restart my computer
now, then click OK to restart the PC to activate the driver.