B.123
FIGURE B4.5c Flexibility and stress intensification factors (Do/tn 100). (Figure NC-3673.2(b)1, Section III, Division 1, ASME B & PV Code, 1998. Courtesy of ASME.)
FIGURE B4.5c (Continued) Flexibility and stress intensification factors (Do/tn 100). (Figure
NC-3673.2(b)-1, Section III, Division 1, ASME B & PV Code, 1998. Courtesy of ASME.)
(B4.17)
B.125
FIGURE B4.5c (Continued) Flexibility and stress intensification factors (Do/tn 100). (Figure
NC-3673.2(b)-1, Section III, Division 1, ASME B & PV Code, 1998. Courtesy of ASME.)
For run:
(B4.18)
(B4.19)
where F1 =
=
F2 =
Fs =
R=
B.126
TABLE B4.3a SIFs for Typical Weldolet Branch Connections (Run Pipe
Size: NPS 1 or DN 40)
1 in = 25.4 mm
(B4.20)
TABLE B4.3b SIFs for Typical Weldolet Branch Connections (Run Pipe
Size: NPS 2 or DN 50)
1 in = 25.4 mm
1 in = 25.4 mm
TABLE B4.3c SIFs for Typical Weldolet Branch Connections (Run Pipe Size: NPS 2 (DN 65) and NPS 3 (DN 80)
B.127
Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
Copyright 2004 The McGraw-Hill Companies. All rights reserved.
Any use is subject to the Terms of Use as given at the website.