Beruflich Dokumente
Kultur Dokumente
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
Item
3
Nos.
HEAT EXCHANGER
C
Supply and install plate and frame heat exchanger as specified complete
with all valves, strainers, pressure gauges, flanged pipe connections to
header pipes, protective devices & controls.
Chilled water circulation pump as specified complete with inertia base and
anti-vibration isolators and all valves, strainers, interconnecting pipework
and flanged pipe connections to main flow and return pipes and controls,
electrical connections.
215 TR
Item
2
Nos.
Item
Nos.
Nos.
Nos.
Dosing pot complete with all valves piping, filling bowl and pipe
connections to main flow and return pipes.
No.
No.
Contract Documents
Volume 2 - Bills of Quantities
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
Fan coil units in all building as specified complete with two port control
valve, chilled water coil, motor, three speed fan, drain pan, filters, drain
vent, balancing and isolating valves, all protective devices, drain to waste,
anti-vibration mountings, joints to pipework and ductwork and all
necessary electrical connections and remote wall mounted thermostats
and controller where applicable.
Item
40
Nos.
10
Nos.
Nos.
Nos.
105
Nos.
74
Nos.
No.
68
Nos.
Nos.
Contract Documents
Volume 2 - Bills of Quantities
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
69
Nos.
Nos.
68
Nos.
DX-Split units, capacities and location as per drawings. With all necessary
electrical connections
No.
No.
Fresh air handling units with thermal wheel and horse shoe heat pipe, as
specified in typical details, complete with three port control valve, chilled
water coil, heating coil, motor, fans drain pan, filters, drain vent, balancing
and isolating valves, all protective devices, sound attenuator, drain to
waste, joints to and ductwork and all necessary control & electrical
FAHU-M-01
FAHU-M-02
FAHU-R-01
FAHU-R-02
FAHU-B1-01
Item
Item
No.
No.
No.
No.
No.
Contract Documents
Volume 2 - Bills of Quantities
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
Wall exhaust fan, capacities and locations as per drawings. with all
necessary electrical connections.
Item
Item
SPF-1
No.
SPF-2
No.
SPF-3
No.
LPF-1
Item
No.
Contract Documents
Volume 2 - Bills of Quantities
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
Tube axial exhaust/fresh air car park Ventilation (Fire Rated) fans with
sound attenuator and all electrical connections, capacities and locations as
per drawings.
No.
No.
No.
No.
No.
No.
No.
No.
No.
Item
Contract Documents
Volume 2 - Bills of Quantities
ITEM
DESCRIPTION
QTY UNIT
RATE
AED
AMOUNT
AED
No.
No.
No.
No.
No.
No.
Chilled water pipe work black steel with schedule 40 and fittings to
complete with rigid sectional insulation as specified.
Item
25mm ditto
(1")
Item
32mm ditto
(1.25")
Item
40mm ditto
(1.5")
Item
Item
ITEM
DESCRIPTION
Contract Documents
Volume 2 - Bills of Quantities
QTY UNIT
RATE
AED
AMOUNT
AED
50mm ditto
(2")
Item
65mm ditto
(2.5")
Item
80mm ditto
(3")
Item
Item
Item
Item
Item
Item
Aluminium cladding over the insulation for the exposed pipework on roof
and within OTS.
Item
Condensate Drain
J
Allow for all condensate drain pipework to air handling unit and/or fan coil
units.
Item
Item
Item
Allow for all valves as required by the specification and shown on the
drawings.
Item
Item
ITEM
DESCRIPTION
Contract Documents
Volume 2 - Bills of Quantities
QTY UNIT
RATE
AED
AMOUNT
AED
Duct Work
A
Item
Item
Fresh Ductwork
Item
Item
Allow for thermal and acoustic insulation to the supply, return ductwork as
required by the specification.
Item
Item
Item
Item
Item
Allow for all fire dampers as indicated on drawings and as required by the
local regulations.
Item
Allow for aluminium cladding over the insulation for fresh air duct work on
roof and within OTS.
Item
Item
Extract Diffusers/Grilles/
Item
ITEM
DESCRIPTION
Contract Documents
Volume 2 - Bills of Quantities
QTY UNIT
RATE
AED
AMOUNT
AED
Free standing cubicles multi-tier type motor control and supply distribution
panels including all incoming and outgoing circuit breakers, motor starters,
controls, indicator, bus bars, etc. complete as specified and shown on the
drawings for air conditioning system.
Item
Item
(BMS) Control and wiring, electric isolators and all protective devices for
proper operation.
Item
Allow for protective and decorative painting, insulated peech wood block
supports as specified.
Item
Item
Allow for earthing all the items and control panels of air-conditioning and
ventilation equipment.
Item
Item
Allow for all builders work including setting out, marking, cuttings or
forming holes, mortises, chases or the like and the co-ordination with other
engineering installations.
Item
ITEM
DESCRIPTION
Contract Documents
Volume 2 - Bills of Quantities
QTY UNIT
RATE
AED
AMOUNT
AED
Painting
A
Item
Sundries
B
Item
Item
The tenderer is required to detail below any additional items with quantities
and rates, which he deems necessary to arrive at the lumpsum Tender
Sum but the same is not included in this Section of Works. Should the
tenderer fail to provide any additional items herein, it will be considered
that his lumpsum price include for all items shown on the Drawing and
described in the Specification. Hence no subsequent claim for any
additional item will be accepted.
Item
Item
ITEM
DESCRIPTION
Contract Documents
Volume 2 - Bills of Quantities
QTY UNIT
RATE
AED
AMOUNT
AED
Collection
Page 1 / 11
Page 2 / 11
Page 3 / 11
Page 4 / 11
Page 5 / 11
Page 6 / 11
Page 7 / 11
Page 8 / 11
Page 9 / 11
Page 10 / 11