Beruflich Dokumente
Kultur Dokumente
-V- New
Controllers CECC
Key features
Application
Controller
State-of-the-art programming
The controllers CECC are modern,
compact and versatile controllers that
enable programming with CoDeSys
according to IEC 61131-3.
Fieldbus interfaces
In addition, the CECC offers an
IO-Link master and an
IO-Link device interface
PROFIBUS
EtherCAT
DeviceNet
CANopen
AS-interface
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Peripherals overview
1
2
3
7
4
Mounting attachments and accessories
Brief description
Page/Internet
The integrated IO-Link interface of the CECC enables quick and easy connection of Festo valve
terminals and sensors to a controller
Plug connector for self-assembly with 2, 5, 6, 8 or 24 pins
10
cpv
vtug
vtub
cteu
The software CoDeSys V3 with the order code GSPF-CD-3 enables standardised programming
according to IEC 61131-3 using object-oriented additional functions
10
2
3
4
5
6
7
Controller
CECC
Plug
NECC
Connecting cable
NEBU
Valve terminal
CPV
Valve terminal
VTUG
Valve terminal
VTUB
Input module
CTSL
Software
CoDeSys V3
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Technical data
-P-Q-
Voltage
19.2 30 V DC
Temperature range
0 +50 C
CECC-LK
CPU data
Status displays
Electrical connection technology for I/O
Resistance to vibration
Resistance to shock
Relative air humidity
[%]
Protection class
Electrical protection class
Product weight
[g]
Note on materials
CECC-LK
Operating voltage
Current consumption at 24 V DC
Ambient temperature
Storage temperature
CE marking
Approval
19.2 30
100
0 55
25 +70
To EU EMC Directive
RCM trademark
[V DC]
[mA]
[C]
[C]
CECC-D
CECC-S
CECC-D
CECC-S
20.4 30
Encoder inputs
Type
CECC-LK
CECC-D
CECC-S
Number
Resolution
Signal range
Max. input frequency
Encoder supply voltage
1
32
5, differential (RS 422)
1000
5 V DC (100 mA)
[bit]
[V]
[kHz]
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Technical data
Digital inputs
CECC-LK
Number
Switching logic
Fast clock pulse inputs
Input signal delay
Input voltage
Nominal value for TRUE
Nominal value for FALSE
Electrical isolation
Status display
Permissible connecting cable length
[V DC]
[V DC]
[V DC]
[m]
CECC-D
CECC-S
CECC-D
CECC-S
CECC-LK
CECC-D
CECC-S
USB 1.1
CAN bus
3
2x RS 232 / 1x RS
485-A/422-A
Plug
300 375,000
CECC-D
CECC-S
IO-Link
I-Port
12
Positive logic (PNP)
2, each with max. 200 kHz
Typically 3 ms
24
15
5
Yes, via optocoupler
LED
30
Digital outputs
CECC-LK
Number
Switching logic
Contact
Output voltage
Output current
Electrical isolation
Status display
Switching frequency
Protection against short circuit
[V DC]
[mA]
[kHz]
8
Positive logic (PNP)
Transistor
24
500
Yes, via optocoupler
LED
Max. 1
Yes
Serial interfaces
USB interface
Fieldbus interface type
Number
Type
Connection technology
Baud rate
[bit/s]
Fieldbus interface
Connection technology
Transmission rate
[kbps]
Galvanic isolation
Ethernet
CECC-LK
Number
Connector plug
Supported protocols
Transmission speed
Protocol
[Mbps]
1
RJ45
TCP/IP, EasyIP, Modbus TCP
10/100
CANopen
IO-Link
I-Port
Modbus TCP
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Technical data
Programming
CECC-LK
Programming software
Programming language according to
IEC 61131-3
CECC-D
CECC-S
CECC-LK
CECC-D
CECC-S
Master 4
Device 1
Device A
Master B
Device V 1.0
Master V 1.1
Plug
Cage clamp
Device, 3-pin
Master, 5-pin
Configurable via software
Device COM1 (4.8 kB), COM2
(38.4 kB), COM3 (230 kB)
Master SIO, COM1 (4.8 kB),
COM2 (38.4 kB), COM3 (230 kB)
Device A
Master B
Device 1
Master 4
3.5/port
C/Q green LED
C/Q red LED
L+ green LED on
L+ green LED off
Master parameterisable 2 - 32 bytes
Master parameterisable 2 - 32 bytes
Master 2 kB per port
Device 3.2 ms
Master 5 ms
0x550000
0x550001
0x550002
0x550003
0x550004
Master 1
Device 1
Device A
Master B
Device V 1.0
Master V 1.1
Plug
Cage clamp
Device, 3-pin
Master, 5-pin
Configurable via software
Device COM1 (4.8 kB), COM2
(38.4 kB), COM3 (230 kB)
Master SIO, COM1 (4.8 kB),
COM2 (38.4 kB), COM3 (230 kB)
Device A
Master B
Device 1
Master 4
3.5/port
C/Q green LED
C/Q red LED
L+ green LED on
L+ green LED off
Master parameterisable 2 - 32 bytes
Master parameterisable 2 - 32 bytes
Master 2 kB per port
Device 3.2 ms
Master 5 ms
0x550000
0x550001
0x550002
0x550003
0x550004
IO-Link
Number of ports
Port type
Protocol
Connection technology
Communication mode
Port type
Number of ports
Master, output current
Communication
Ready status display
Process data width OUT
Process data width IN
Memory card
Minimum cycle time
Device ID
[A]
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Technical data
Download CAD data www.festo.com
Dimensions
CECC-LK
CECC-D
Type
CECC-LK
CECC-D
B1
B2
D1
H1
H2
H3
H4
H5
H6
L1
L2
L3
48.15
48.15
44.6
44.6
4.5
4.5
106
106
100
100
90.5
90.5
81
81
72
72
35.2
35.2
130
130
126.11
126.11
122.2
122.2
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Technical data
Download CAD data www.festo.com
Dimensions
CECC-S
Type
CECC-S
Ordering data
Controllers
CECC-LK
CECC-D
CECC-S
B1
B2
D1
H1
H2
H3
H4
H5
H6
L1
L2
L3
47.2
43.6
4.5
106
100
90.5
81
72
35.2
130
126.1
122.2
Brief description
Part No.
Type
With 14 digital inputs and 8 digital outputs, Ethernet, USB, CANopen, 4 IO-Link masters,
1 IO-Link device
With 14 digital inputs and 8 digital outputs, Ethernet, USB, CANopen
With 14 digital inputs and 8 digital outputs, Ethernet, USB, CANopen, 2 RS232,
1 RS485/RS422/Encoder, 1 IO-Link masters, 1 IO-Link device
574418
CECC-LK
574415
574416
CECC-D
CECC-S
Internet: www.festo.com/catalogue/...
-V-
-V- New
Controllers CECC
Accessories
Download CAD data www.festo.com
Dimensions
Plug
Type
B1
B2
H1
H2
L1
L2
L3
NECC-L2G4-C1-M
13
7.5
21.9
14
21
10.5
3.5
Dimensions
Plug
Type
NECC-L2G2-C1
NECC-L2G5-C1
NECC-L2G6-C1
NECC-L2G8-C1
NECC-L2G24-C1
B1
13
H1
21.9
H2
L1
L2
L3
14
7
17.5
21
28
84
3.5
14
17.5
24.5
80.5
3.5
Materials
Corrosion resistance class CRC1)
Note on materials
1)
1
RoHS-compliant
Dimensions
Plug
Type
B1
H1
H2
L1
L2
L3
NECC-L2G4-C1
13
21.9
14
14
10.5
3.5
Internet: www.festo.com/catalogue/...
-V- New
Controllers CECC
Accessories
Ordering data
Description
PU2)
Part No.
Type
575303
NECC-L2G4-C1-M
1
1
1
1
1
1
575302
8024782
575304
575305
575306
575307
NECC-L2G2-C1
NECC-L2G4-C1
NECC-L2G5-C1
NECC-L2G6-C1
NECC-L2G8-C1
NECC-L2G24-C1
576031
NECC-S1G9-C2-M
Description
Part No.
Type
541330
NEBU-M12G5-K-2.5-LE5
567843
NEBU-M12W5-K-2.5-LE5
Up to 20 m long1)
574321
574322
574323
NEBU-M12G5-E-5-Q8-M12G5
NEBU-M12G5-E-7.5-Q8-M12G5
NEBU-M12G5-E-10-Q8-M12G5
542000
GSPF-CDS-3
Plug
2)
-V-
Packaging unit
Ordering data
Connecting cables
Programming software
1)
10
Internet: www.festo.com/catalogue/...