Sie sind auf Seite 1von 4

10/09/03

AIR CONDITIONING

FCDKADNA743AAN_dkadna_uk

10:08

Page 4

Packaged air conditioners

SPLIT-SYSTEM DK-A / DN-A


Cooling only
Heatpump

Range
INDUSTRIAL

Electric heating
(in duct)

FCDKADNA743AAN_dkadna_uk

10/09/03

10:08

Page 1

Packaged air conditioners

SPLIT-SYSTEM
This complete range includes
6 models of "Axial" condensing
units single or dual circuits
depending on models, and
6 models of indoor air treatment
units for ducted air distribution.
DN-A INDOOR AIR
TREATMENT UNITS

The range corresponds perfectly


to all air conditioning and heating
requirements in medium to large

DK-A
405/505/605

size premises.

CONDENSING
UNITS

This equipment is particularly

DK-A
205/255/305

suited for the requirements of the


industrial and commercial sectors.

ST S 4370 P
S 5670 P

It offers a multitude of installation


possibilities and is extremely
flexible in operation.
An air filter can be supplied as an
accessory, to be fitted on site.

WAREHOUSES

The split - system


installation provides

FACTORIES

THE ENTIRE UNIT IS


CONTROLLED BY AN

temperature control for

ELECTRONIC CIRCUIT BOARD


WHICH PROVIDES SYSTEM

every area of the building.

OPERATION AND
MANAGEMENT.

In this manner, different

WIRED REMOTE CONTROL

sized rooms can be air

WITH LIQUID CRYSTAL


DISPLAY:

conditioned, depending on

- HEATING - COOLING AND


AUTOMATIC OPERATION

the individual room

SWITCH
- ROOM TEMPERATURE

requirements.

SETTING
- LOCAL OR REMOTE NIGHT

WORKSHOPS

SLOW-DOWN SETTING
- AUTOMATIC RESTARTING
AFTER POWER CUTS.

FIELDS OF APPLICATION

FCDKADNA743AAN_dkadna_uk

10/09/03

10:08

Page 2

Dimensions (in mm) and weight

Cooling
only

Heatpump

Electric
heating

(in ducting)

AIR TREATMENT UNITS


DK-A 205
Net weight : 98 kg
DK-A 255
Net weight : 100 kg

400

A D V A N T A G E S
1350

1060

The models in this range, available in both


"cooling only" and heatpump" versions,
are offered with numerous accessories and

DK-A 305
Net weight : 160 kg
DK-A 405
Net weight : 160 kg

676

options enabling "made to measure" air


conditioning installations to be designed.
1690

The easy to install SPLIT - SYSYTEM packaged


air conditioners can be adapted to any existing

DK-A 505
Net weight : 205 kg
DK-A 605
Net weight : 209 kg

991

704

or newly built building, via a network of ducts.


2100

1064

As standard equipment, this range is fitted with


electronic microprocessor controlled regulation

CONDENSING UNITS

which provides operating and management


control, including "all year round" control for
operating in cooling mode with low outside

DN-A 205
Net weight : 164 kg
DN-A 255
Net weight : 164 kg

1006

temperatures.
THE "AXIAL"
CONDENSING UNITS
ARE TO BE INSTALLED OUTDOORS.
THUS THERE IS NO REQUIREMENT
FOR PROVIDING A TECHNICAL
SERVICES ROOM OR MAKING
BUILDING ALTERATIONS

803

DN-A 305
Net weight : 187kg

903

1006

1003

DN-A 405
Height : 964
Net weight : 317 kg
DN-A 505
Net weight : 378 kg
DN-A 605
Net weight : 405 kg

1003

1165
except
DN-A 405 :

964

1708
PIPING LENGTH: 30 M MAX.
LEVEL VARIATION: 15 M.
25 M FOR COOLING MODELS
(DK-A ABOVE DN-A)

1125

FCDKADNA743AAN_dkadna_uk

10/09/03

10:08

Page 3

TECHNICAL SPECIFICATIONS

COOLING ONLY MODELS DK-A / DN-A

205

255

305

405

505

605

W
BTU/HR

19100
65150

22000
75040

28100
95850

36500
124500

45500
155200

56600
193050

7100

8300

11500

14300

17100

22800

Nominal
Minimum
Maximum

m3/h
m3/h
m3/h

4500
3600
5000

4680
3700
5100

5760
4600
6350

7560
6000
8300

9360
7500
10300

9720
7780
11000

External static pressure


Air treatment unit

daPa

7/21

5/20

10/19

10/19

11/21

14/22

Indoor sound power level


(air discharge)
Outdoor sound power level

dBA
dBA

81
83

82
83

79
87

81
88

80
87

81
93

Refrigerant circuit(s)

Nominal cooling
capacity (1)
Total nominal power input
Fan + cooling

HEATPUMP MODELS DK-A / DN-A


Refrigerant circuit(s)

205RC

255RC

305RC

405RC

505RC

605RC

Nominal cooling
capacity (1)

W
BTU/HR

19100
65150

22000
75040

28100
95850

36500
124500

45500
155200

56600
193050

Nominal heating
capacity (2)

W
BTU/HR

19100
65150

21800
74300

27300
93100

36500
124500

43800
149500

56100
191300

W
W

7100
6400

8300
7000

11500
8000

14300
12100

17100
14100

22800
20000

Nominal
Minimum
Maximum

m3/h
m3/h
m3/h

4500
3600
5000

4680
3700
5700

5760
4600
6350

7560
6000
8300

9360
7500
10300

9720
7780
11000

External static pressure


Air treatment unit

daPa

7/21

5/20

10/19

10/19

11/21

14/22

Indoor sound power level


(air discharge)
Outdoor sound power level

dBA
dBA

81
83

82
83

79
87

81
88

80
87

81
93

PIPING LENGHT
Maximum length
Level variance (3)

m
m

30
15

30
15

30
15

30
15

30
15

30
15

"Gas" pipe > 20 m


"Gas" pipe < 20 m

Inch
Inch

1 1/8
1 1/8

1 1/8
1 3/8

1 1/8
1 3/8

1 1/8
1 1/8

1 1/8
1 3/8

1 1/8
1 3/8

"Liquid" pipe > 20 m


"Liquid" pipe < 20 m

Inch
Inch

1/2
1/2

1/2
5/8

1/2
5/8

1/2
1/2

1/2
5/8

1/2 (>10m)
5/8 (<10m)

Total nominal power input


Fan + cooling
Fan + heating

Airflow

The values are given for nominal voltage supply; NF EN 255.2 - NF EN 814.2 standards.
(1) Type A international conditions: 27 C / 19 C wet bulb. Outdoor air 35 C / 24 C wet bulb.
(2) International conditions: 20 C / 12 C wet bulb. Outdoor air 7 C / 6 C wet bulb.
(3) Refer to technical specifications for vertical piping length (25 m max. depending on configuration in Cooling Only)

Your distributor

ACE MARKETING - RCS VERSAILLES B 421 305 996 - Specifications subject to change without notice - Pictures non contractual -

3N~400V-50Hz

REF : FCDKA/DNA 743A/AN

Power supply

- Printed in E.U.

Airflow