Beruflich Dokumente
Kultur Dokumente
Important User
Information
Because of the variety of uses for the products described in this publication, those responsible
for the application and use of this control equipment must satisfy themselves that all necessary
steps have been taken to assure that each application and use meets all performance and safety
requirements, including any applicable laws, regulations, codes and standards.
The illustrations, charts, sample programs and layout examples shown in this guide are intended
solely for purposes of example. Since there are many variables and requirements associated
with any particular installation, Rockwell Automation does not assume responsibility or liability
(to include intellectual property liability) for actual use based upon the examples shown in this
publication.
Table of Contents
Overview
1502
1503F/C/S
1503VC
22
22
22
23
23
23
23
24
Table of Contents
1503E
857
25
25
25
25
25
26
27
28
29
29
31
37
38
39
41
42
43
44
865
Appendix A
Appendix B
Appendix C
Voltage Ranges
Voltage Ranges ......................................................................................... 51
Overview
Rockwell Automation has produced quality Medium Voltage products to meet the
requirements of all types of industries for well over six decades.
From the original oil-immersed contactor to air break and vacuum contactors, to solid-state
controllers such as Smart Motor Controllers and AC Variable Frequency Drives, Rockwell
Automation has developed and built a medium voltage product line that satisfies industries who
are demanding more safety, less maintenance, longer life and reliability in motor control equipment.
Added to those demands is the need for smaller, more flexible medium voltage products that
are more efficient and reduce building and expansion costs.
OEM frames and components leverage the existing family of motor controllers built by
Rockwell Automation. They also incorporate some of the most fundamental, high volume
components available in our OEM product line for Original Equipment Manufacturers and
electrical equipment companies.
Bulletin 1502 vacuum contactors are a comprehensive line of vacuum contactors used as
isolating contactors or as bypass contactors. Light weight and maintainability are but two of
the features of this fixed-mounted design.
Bulletin 1503F OEM components are a series of medium voltage frame-mounted
components designed to mount into new or existing structures or enclosures. These
assemblies can also be used to retrofit existing motor controllers. These products are
available as a complete OEM frame or sold individually as components.
Bulletin 1503E MV SMC Flex OEM kits are a series of solid-state reduced voltage
components designed to mount into new or existing structures or enclosures. These
assemblies can also be used to retrofit existing motor controllers. These products are
available as an OEM frame and components.
Bulletin 857 is a motor/feeder protection relay that includes all the essential functions
needed to protect motors and feeders in diverse industrial applications. The programmable
857 includes the optional arc protection feature, thermal, trip circuit supervision and circuit
breaker protection. The device can include numerous communication protocols, as well as a
twelve-channel RTD scanner.
Bulletin 865 is a differential protection relay that includes the necessary functions to protect
transformers for distribution networks of utilities, industry power plants and offshore
applications, as well as motor and generator differential protection. The devices
programmable functions include thermal and circuit breaker protection, and numerous
communications protocols. An optional arc flash protection is available.
Rockwell Automation also offers standard motor controllers, solid-state reduced voltage
starters, and variable speed drives with standard, yet flexible, product configurations for all
product lines.
Rockwell Automation offers several OEM programs, such as customer-specific program
(custom engineered options and configurations with a standard quick-ship delivery). Contact
your local Rockwell Automation office for more information on these programs and other
OEM products.
1502
Medium Voltage
400 A
800 A
Description
The Allen-Bradley Medium Voltage 400 and 800 ampere vacuum
contactors offer:
1502
400 A
Voltage Ratings
Maximum Rated Voltage
System Voltages
Dielectric Voltage Withstand Rating
2400 V
5000 V
7200 V
2400 V
5000 V
7200 V
Current Peak cycle (kA)
For 1 second (kA)
For 30 seconds (kA)
120 VAC
800 A
7200
7200
2400
3300
4800
6600
18.2 / 20 kV (IEC)
60
400
6300
6300
6000
25
50
75
60
6.0
2.4
0.5
4.0
4160
6900
60
800
12000
12000
12000
50
100
150
85
12.0
4.8
0.5
8.0
110 VDC
VAC :
VCL = 2 x VCTL
(Max.)
VDC : VCL = VCTL
5.6
6.0
102
84
N/A
N/A
N/A
N/A
12
0.7
95
75
5.2
70
7.3
11.5
0.13
102
75
8.3
NA
0.11
190
140
13.1
13.1
0.24
102
75
10.4
NA
0.19
190
140
The voltage and current ratings listed are valid up to 1,000 m (3,300 feet).
Please refer to the Altitude Derating Chart on page 7 for ratings above this altitude.
The IEC rating at 7200 V (RMS Sym.) is 5300 Amps / 66 MVA.
Control voltage, as measured at the input of the IntelliVAC control module (when Series E data entered)
A contactor drop-out delay may be configured with the IntelliVAC control module (refer to publication 1503-UM052_-EN-P).
The full altitude range is available with the IntelliVAC control module only, and the IntelliVAC is to be configured accordingly (refer to
publication 1503-UM052_-EN-P). The standard mechanical latch contactors, if used with electro-mechanical control, are designed
for -1000 to 1000 meters (-3300 to 3300 feet). Higher altitudes are possible by changing the contactor return spring.
Altitude adjustment (manual) is required to support full altitude range.
The number of contactor auxiliary contacts depends on the contactor type. Some of the contactors are used in the typical control schemes used.
Series D contactors are suitable for electro-mechanical (relay) control only.
1502
400 A
800 A
2500
100
1000
600
150
250
100
250
600
150
Operational Characteristics
Mechanical Life (Operations) x 1000
Electrically Held
Mechanical Latch
200
60 FDO / 240 NDO
150
60
200
240
60
2000 KVAR
3000 KVAR
4000 KVAR
-1000 to 5000 meters
(-3300 to 16500 ft.)
45 kg (100 lbs)
A600
2 N.O. / 2 N.C.
The voltage and current ratings listed are valid up to 1,000 m (3,300 feet).
Please refer to the Altitude Derating Chart on page 7 for ratings above this altitude.
The IEC rating at 7200 V (RMS Sym.) is 5300 Amps / 66 MVA.
Control voltage, as measured at the input of the IntelliVAC control module (when Series E data entered)
A contactor drop-out delay may be configured with the IntelliVAC control module (refer to publication 1503-UM051_-EN-P).
The full altitude range is available with the IntelliVAC control module only, and the IntelliVAC is to be configured accordingly (refer to
publication 1503-UM051_-EN-P). The standard mechanical latch contactors, if used with electro-mechanical control, are designed
for -1000 to 1000 meters (-3300 to 3300 feet). Higher altitudes are possible by changing the contactor return spring.
Altitude adjustment (manual) is required to support full altitude range.
The number of contactor auxiliary contacts depends on the contactor type. Some of the contactors are used in the typical control
schemes used.
Series D contactors are suitable for electro-mechanical (relay) control only.
FDO = Fast Drop Out, NDO = Normal Drop Out
1502
FU
CR1
CR1
CR2
CR2
CR2
CR2
MOV
D
BLK
CC
N
B
HC
B
CR2
STOP
START
OVERLOAD
CR1
CR1
M
CR1
CR2
CC
HC
MV Vacuum Contactor
Control Relay
Economizing Relay
Closing Coil
Holding Coil
Note: Some of the control circuit devices shown in addition to M (MV vacuum contactor) are available as optional equipment.
(See Control Panel Specifications on pages 14 and 24.)
1502
*
CONTROL
POWER
FUSE
EMERGENCY
STOP
M-INTELLIVAC
L
INPUT POWER
G
STOP
7
OPEN
- 8
CLOSE
- 10
START
16
15
CONTACTOR
STATUS
14
13
MODULE
STATUS
CAPACITOR
(OPTIONAL)
1 EC
2 +
TCO
11
AUX
12
CCO
4
3
MOV
6
5
CONFIGURATION
DIP SWITCHES
INTERFACE
CONNECTOR
(RS485)
INTELLIVAC PLUS
(OPTIONAL)
INPUT COM
25
ISOLATION SWITCH
24
INPUT 8
23
INPUT 7
22
INPUT 6
21
INPUT 5
20
INPUT 4
19
INPUT 3
18
INPUT 2
17
INPUT 1
AUX 1
AUX 2
AUX 3
LOCAL
OFF
REMOTE
REMOTE START
OVERLOAD
28
29
26
27
OUTPUT B
OUTPUT A
REMOTE EQUIPMENT
PLUS
STATUS
CUSTOMER WIRING
RS485 ADR
NETWORK
STATUS
DEVICENET
24V
SH
1502
399 (15.70)
438 (17.25)
127 (5)
to Center
5 TO CENTER [127]
Front View
Side View
341.2 (13.43)
470.4 (18.52)
158.2 (6.23)
to Center
Front View
Side View
1502
400 Amp
Control Circuit
Electromechanical
IntelliVAC or
IntelliVAC Plus
Electromechanical
800 Amp
IntelliVAC or
IntelliVAC Plus
Contactor Description
Wire Harness
Catalog Number
Catalog Number
1502-V4DBDA-__
1502-V4DBDD-__
1502-VC4DBDB-__
1502-VC4DBDA-0
1502-VC4DBDB-0
1502-V8DXDA-__
1502-V8DXDD-__
1502-V8DXDB-__
1502-VC8DXDA-__
1502-VC8DXDB-__
1503-WHE4D
1503-WHM4D
1503-WHE4V
1503-WHM4V
1503-WHE8D
1503-WHM8D
1503-WHE8V
1503-WHM8V
Electrically-held, 400 Amp, Vacuum Contactors (Series E and later) can be retro-fitted with a mechanical
latch assembly using this kit (1502-4MLK). The kit is suitable for use with vacuum contactors 1502-VC4DBDA-0,
as listed in the above table.
The kit comes with all required components and instructions.
NOTE: The kit must be installed by qualified personnel.
1502-4MLK
Return Spring
Plating Color
(400 A only)
Green
10 A
20 A
6.0 kV
Blue
20 A
40 A
12.0 kV
Black
30 A
60 A
18.0 kV
Olive
40 A
80 A
24.0 kV
Altitude Rating
800 A
Reduce B.I.L.
Withstand Rating
by :
1503F
Description
The 1503F OEM controller is an open-frame-style structure that consists of a bolted construction frame
housing the vacuum contactor, non-load-break isolation switch, and the isolation switch handle module.
A control panel is also included and connects to the vacuum contactor to provide the necessary control
functions for operating the controller. Available for voltages ranging from 2400 to 7200 volts.
The 1503F OEM controller requires additional components in order to fully construct a complete motor
starter such as current transformers, power fusing, a control power transformer, overload protection,
appropriate control circuitry for the application, and a suitable enclosure.
The factory-tested OEM frame includes as standard:
Non-load-break fused isolation switch (see Switch Specifications, page 15)
Isolation switch operating handle (see Handle Specifications, page 21)
2 N.O./2 N.C. auxiliary contacts on the isolator switch
400 Amp
Power Fuses
Ferraz-Shawmut medium voltage power fuses are recommended for the Bulletin 1503F. These motor
fuses have been tested and meet the co-ordination requirements for the Bulletin 1502 vacuum contactor.
1503F
Typical Schematic 120 V Control Circuit, 400A Electrically Held Contactor with IntelliVAC Control (including option 1503C-CPSx)
ISOLATING SWITCH
IS
DOOR INTERLOCK
L1
CUSTOMER
INCOMING LINE
CT1
T1
F1
L2
CT2
T2
F1
L3
MOTOR
CT3
T3
F1
M
CURRENT LIMITING
POWER FUSES
(CUSTOMER SUPPLIED)
GRD
49
OVERLOAD
CUSTOMER SUPPLIED
120V AC
5(L)
6(N)
GRD
ISa
OFF
8
X
ISb
7
(6)
(5)
9
(7)
NORMAL
(8)
10
TEST
X (1)
(2)
(3)
(4)
11
60Hz
12
M-IV
F3 4.0A
15
2.0A
F7
13
14
1 EC
2 +
TCO
11
AUX
12
6
HCO
5
L1
1A
1B
STOP
4
3
17
MOV
20
START
2
M-IV
3
M-IV
15
9 + - 10
CLOSE
OVERLOAD
12
16
CONTACTOR
STATUS
LEGEND
CUSTOMER WIRING
REMOVE JUMPER WHEN CONNECTING REMOTE EQUIPMENT
"IEEE" NUMBER FOR PROTECTIVE DEVICE
REMOTE EQUIPMENT
1503F
546 (21.50)
4 ? .515
Mounting
Holes
1279 (50.36)
538 (21.17)
691 (27.22)
97 (3.83)
25 (0.97)
Front View
10
556 (21.89)
Bottom View
1503F
600 A
594 [23.37]
1489
[58.63]
768
[30.22]
614
[24.17]
632 [24.89]
683 [26.88]
Front View
Side View
11
1503F
Frame
Voltage
(kV)
Contactor
Type
Fuse Clip
Control Method
Electro-mechanical
Clip-on
IntelliVAC
Electrically
Held
Electro-mechanical
Bolt-on
2.3 5.0
Base
MC
Plus
Base
MC
Plus
Electro-mechanical
Base
IntelliVAC
Plus
Electro-mechanical
Base
IntelliVAC
Plus
IntelliVAC
Clip-on
Mechanical
Latch
Bolt-on
400
Electro-mechanical
Clip-on
IntelliVAC
Electrically
Held
Electro-mechanical
Bolt-on
5.1 6.9
Mechanical
Latch
Bolt-on
12
Base
MC
Plus
Electro-mechanical
Base
IntelliVAC
Plus
Electro-mechanical
Base
IntelliVAC
Plus
IntelliVAC
Clip-on
Base
MC
Plus
Control Voltage
110 to 120 VAC
220 to 230 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
220 to 230 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
220 to 230 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
220 to 230 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
110 to 240 VAC or
110 to 250 VDC
110 to 120 VAC
110 to 240 VAC or
110 to 250 VDC
Catalog Number
1503F-E4GCD
1503F-E4GCE
1503F-E4GCU
1503F-E4GCUM
1503F-E4GCUP
1503F-E4GBD
1503F-E4GBE
1503F-E4GBU
1503F-E4GBUM
1503F-E4GBUP
1503F-M4GCD
1503F-M4GCU
1503F-M4GCUP
1503F-M4GBD
1503F-M4GBU
1503F-M4GBUP
1503F-E4KCD
1503F-E4KCE
1503F-E4KCU
1503F-E4KCUM
1503F-E4KCUP
1503F-E4KBD
1503F-E4KBE
1503F-E4KBU
1503F-E4KBUM
1503F-E4KBUP
1503F-M4KCD
1503F-M4KCU
1503F-M4KCUP
1503F-M4KBD
1503F-M4KBU
1503F-M4KBUP
Refer to current derating table on page 7 for use above 1,000 m (3,300 ft.).
Electromechanical Control includes a complete 1503C-xxx control panel assembly, for mounting by customer.
All IntelliVAC Control options include an IntelliVAC (or IntelliVAC Plus / IntelliVAC MC) module and suitable 1503-WHxxx wire harness.
A control power selector assembly, 1503C-CPSx, may be ordered separately (if required).
IntelliVAC Plus is an enhanced version of control for vacuum contactors. Refer to page 22 for additional details.
IntelliVAC MC is used for multi-contactor control schemes. One IntelliVAC Plus is required for multi-contactor schemes, and additional
frames require an IntelliVAC MC. IntelliVAC Plus includes embedded DeviceLogix control for certain multi-contactor schemes.
1503F
Voltage
(kV)
Contactor
Type
Fuse Clip
Control Method
Electro-mechanical
Electrically
Held
Bolt-on
Mechanical
Latch
Bolt-on
IntelliVAC
2.3 5.0
IntelliVAC
Base
Plus
Base
MC
Plus
Electro-mechanical
Electrically
Held
Bolt-on
Mechanical
Latch
Bolt-on
IntelliVAC
5.1 6.9
Electro-mechanical
600
Electro-mechanical
IntelliVAC
Control Voltage
Base
Plus
Catalog Number
1503F-E6GBD
1503F-E6GBU
1503F-E6GBUM
1503F-E6GBUP
1503F-M6GBD
1503F-M6GBU
1503F-M6GBUP
1503F-E6KBD
1503F-E6KBU
1503F-E6KBUM
1503F-E6KBUP
1503F-M6KBD
1503F-M6KBU
1503F-M6KBUP
Refer to current derating table on page 7 for use above 1,000 m (3,300 ft.).
Electromechanical Control includes a complete 1503C-xxx control panel assembly, for mounting by customer.
All IntelliVAC Control options include an IntelliVAC (or IntelliVAC Plus / IntelliVAC MC) module and suitable 1503-WHxxx wire harness.
A control power selector assembly, 1503C-CPSx, may be ordered separately (if required).
IntelliVAC Plus is an enhanced version of control for vacuum contactors. Refer to page 22 for additional details.
IntelliVAC MC is used for multi-contactor control schemes. One IntelliVAC Plus is required for multi-contactor schemes, and additional
frames require an IntelliVAC MC. IntelliVAC Plus includes embedded DeviceLogix control for certain multi-contactor schemes.
13
1503C
Description
Control panel and 10-ft (3.05 m) wire harness for connecting to the vacuum contactor. Control panel
includes control relays, rectifier, MOV, terminal blocks (1492-W4), test switch and plug.
Note: A control panel for 110/120 V, 50/60 Hz shown.
A control panel for 220/240 V, 50/60 Hz does not include test plug. A control panel without a test
switch and plug is available for multiple contactors. See page 43.
Specifications
Description
Control
Cable
Terminal Blocks
Wire Gauge
Specification
110/120 V AC, 50/60 Hz
3.05 m (10 ft)
Qty 27, 1492-W4
#14 AWG
213 (8.38)
Approximate dimensions in millimeters (inches).
224 (8.83)
To Contactor
229 (9.0)
142 (5.58)
Front View
(120 V AC)
Side View
Contactor Type
Electrically held 400 A
Mechanical latch 400 A
Electrically held 800 A
Mechanical latch 800 A
Electrically held 400 A
Electrically held 800 A
Catalog Number
1503C-E4D
1503C-M4D
1503C-E8D
1503C-M8D
1503C-E4E
1503C-E8E
14
1503S
Specifications
Auxiliary contacts:
Contact type:
Contact rating:
Catalog Number
1503S-4C
1503S-4B
1503S-6C
1503S-6B
1503S-8B
15
1503S
Mounting Surface
56.6 [2.23]
60 [2.36]
471 [18.55]
327 [12.89]
Line Terminals
442.7
[17.43]
688
[27.10]
125.2 [4.92]
508 [20]
Terminals
229 [9.03]
50 [1.97]
Front View
Approximate dimensions in millimeters [inches]
16
Side View
1503S
Mounting Surface
56,6 [2.23]
471 [18.55]
60 [2.36]
327 [12.89]
442,7 [17.43]
Line Terminals
Terminals
274.3 [10.80]
835,2 [32.88]
194 [7.63]
508 [20]
50 [1.97]
229 [9.03]
Front View
Side View
17
1503S
187 [7.36]
Mounting Surface
327 [12.89]
471 [18.55]
818.8 [32.24]
442.7 [17.43]
183.8
[7.24]
60 [2.36]
125.2 [4.93]
508 [20]
50 [1.97]
347.5 [13.68]
Front View
Approximate dimensions in millimeters [inches]
18
Side View
1503S
Mounting Surface
187 [7.36]
327[12.89]
[12.89]
327
60 [2.36]
274.3
[10.8]
508[20]
[20]
508
967.9
[38.11]
967.9 [38.11]
442.7
442.7 [17.43]
[17.43]
183.8
[7.24]
471 [18.55]
50 [1.97]
347.5 [13.68]
Front View
Side View
19
1503S
Mounting Surface
30.2 [1.19]
176
[6.93]
369.3 [14.54]
305.3 [12.02]
199.6 [7.86]
1025.4 [40.37]
260 [10.24]
769.6 [30.30]
610.62 [24.04]
459.23 [18.08]
Front View
20
Side View
1503S
Specifications
Padlocking provision: up to 3 padlocks in open position, 1 padlock in closed position
Interlock with the power cell door
Provision for key interlocking
666 [26.23]
575 [22.67]
117
[4.61]
Connection to
Isolation Switch
506
[19.93]
330
[13.00]
3 [0.125]
Clearance
required for
installation
Handle in
OFF position
Isolation Switch
Handle Module
Contactor
Interlock Rod
Catalog Number
400 A
1503-HM1
1503-HM2
21
1503VC
Delayed motor re-start prevents rapid cycling of vacuum contactor, protecting the connector motor
22
Configurable using either RS Networx or handheld configuration terminal (Bulletin 193-DNCT) for DeviceNet
1503VC
Communication board (RS485) to allow the MC module to be controlled by one IntelliVAC Plus for
multi-contactor control schemes
Dimensions
5.1 [0.20]
29.7
[1.17]
IntelliVAC MC
165.9 [6.53]
5.8 [0.228]
(2) places
185.3
[7.29]
174.8
[6.88]
59.4 [2.34]
Catalog Numbers
Control Power
Selector Assembly
IntelliVAC
1503VC-BMC5
Control Power
Selector Assembly
1503C-CPS1
1503C-CPS2
A wire harness for 1502 vacuum contactors is generally required. Refer to page 7.
For use with IntelliVAC control module.
23
1503VC
24
1503E
Features
DeviceNet (20COMM-D)
ControlNet (20COMM-C)
Ethernet/IP (20COMM-E)
Profibus DP (20COMM-P)
Remote I/O (20COMM-R)
RS485 (DFI) (20COMM-S)
Frame
1000-4160V,
180-360 Amp
Required
Power Stacks
1000-6900V
180-600 Amp
Required
Required
Required
Required
Required
Required
Description
SMC Flex
Control Module
Optional
Optional
Optional
Optional
Optional
Optional
(page 42)
25
1503E
ISOLATING SWITCH
IS
DOOR INTERLOCK
100:1
GFCT
(OPTIONAL)
CT1
CT2
CT3
CURRENT LIMITING
POWER FUSES
RR1
RR2
OV2
OV1
CURRENT LIMITING
PRIMARY FUSES
OV3
RS1
S1
CS1
CPT
500 VA
TO SMC-FLEX
(27, 28)
OV S
TEST
C2
+
120V
OV S
TEST
CLGD
CT
X1
RS2
S3
C1
4200V
H1
H2
OV4
S2
OV S
TEST
CLGD
CS2
S4
C3
CT
C4
+
OV S
TEST
CLGD
CT
CLGD
CT
X2
CL
RX1 TX1 G
RX1 TX1 G
RX1 TX1 G
ISa
RX1 TX1 G
2
TO CONTROL CIRCUIT
L3
L2
L1
26
FROM
CONTROL
CIRCUIT
PHASE B
GATE TRANSMITTERS
PHASE A
U16
U18
U20
TB1
L1
L2/N
G
TB6
FROM CLT
GDPS
CT INPUTS
TX13
TX14
TX15
TX16
TX17
TX18
Vcom
TB5
AA+
BB+
CC+
J3
POWER
OUT
PHASE C
CAUTION:
24C
TEMP.
TX7
TX8
TX9
TX10
TX11
TX12
POWER
IN
TO SMC-FLEX
(11, 12)
T1
T2
T3
MTR
1503E
27
1503E
Installation
Description
Power Wiring
Control Wiring
Keypad
Set-up
Software
Standard
Features
Optional
Features
28
The MV SMC Flex Controller must be wired with an isolation contactor as per
local/regional codes. Bypass contactors must be employed after the controller
has brought the motor to full speed.
2- and 3-wire control for a wide variety of applications.
The MV SMC Flex Controller is configured with the front keypad and backlit LCD
display.
Parameter values can be downloaded to the MV SMC Flex Controller with Drive
Tools programming software and an optional (20COMM-x) communication
module.
One serial (DPI) port provided for connection to optional human interface
One serial (DPI) port provided for optional 20-COMMx modules (mounted within
SMC Flex control module)
Starting Modes
Soft Start with selectable kickstart, Soft Stop, Current Limit Start with selectable
kickstart, Linear Acceleration with selectable kickstart, Linear Deceleration, Dual
Ramp with selectable kickstart, Full Voltage, Preset Slow Speed
Metering
Amps, volts, elapsed time, motor thermal capacity usage, power (MW, MWh, PF)
Status Indication
Auxiliary Contacts
Control Voltage
Available in two lengths (2.5 m and 5.0 m). Provides isolation between interface
board and power stacks.
Soft Stop
Pump Control
Helps reduce fluid surges in centrifugal pumping systems during starting and
stopping period. Starting time is adjustable from 0 to 30 seconds. Depending on
application, stopping time may be adjusted.
Bypass Contactor
Communication Modules
1503E
Description
The Bulletin 1503 MV SMC Flex OEM frame is a self-contained power unit that can be easily installed.
To fully install the frame, the OEM must complete the following:
Connect power cables from the power stacks in the frame to the input power disconnection mechanism,
bypass contactor, and motor;
Mount the SMC Flex control module on the interface board and connect the interface board to the
voltage sensing board with wires, and the gate driver boards with fiber optic cables;
Connect the interface board to OEM-supplied current transformers.
The vacuum bypass contactor is connected in parallel with the SCRs and is controlled by a contact on
the SMC Flex control module that opens and closes the vacuum contactor.
The frame includes:
Three Power Stacks, comprised of heat sinks, SCRs, snubber caps and resistors, and gate driver boards
Voltage sensing circuit board
Installation Manual
Specifications
Description
Input Voltages
(50/60 Hz)
Ambient Temperature
Power Section
Repetitive Peak
Inverse Voltage Rating
Thermal Capacity
dv/dt Protection
180 A
360 A
Maximum Heat
Dissipation (kW)
Altitude
Net Weight
(Shipping)
800 to 2400 V
2401 to 5000 V
180 A
360 A
7
13
14
26
0 to 1000 m (0 to 3,300 ft)
(See Controller Deratings Table on page 7)
1000 to 2400 V 116 kg (255 lbs)
3300 to 4160 V 125 kg (276 lbs)
Continuous
.25
.25
29
1503E
Catalog Number
1503E-FRZ1T
1503E-FRZ1A
1503E-FRAT
1503E-FRAA
1503E-FRCT
1503E-FRCA
1503E-FRET
1503E-FREA
Voltage ranges :
640 [25.19]
900 [35.42]
890
[35.04]
Front View
30
Side View
1503E
Description
The Bulletin 1503 MV SMC Flex OEM Power Stack consists of three modular power stacks that provide
excellent mounting flexibility. To fully install the power stacks, the OEM must complete the following:
Connect power cables from the power stacks to the input power disconnection mechanism, bypass
contactor, and motor;
Mount the SMC Flex control module on the interface board and connect interface board to the voltage
sensing board and the gate driver boards with fiber optic cables;
Mount voltage sensing board and connect to the line and load terminals;
Connect the interface board to OEM-supplied current transformers.
The vacuum bypass contactor is connected in parallel with the SCRs and is controlled by a contact on
the SMC Flex control module that opens and closes the vacuum contactor.
The power stacks include:
Three power stacks, comprised of heatsinks, SCRs, snubber caps and resistors
Gate driver boards and mounting hardware
Installation Manual
Specifications
Description
Input Voltages
(50/60 Hz)
Ambient
Temperature
Power Section
(for 3 phases)
Repetitive Peak
Inverse Voltage Rating
Thermal Capacity
dv/dt Protection
Maximum Heat
Dissipation (kW)
31
1503E
426.7
[16.80]
446.9 [17.60]
Front View
457.7 [18.02]
Side View
457.7 [18.02]
214.4 [8.44]
139.7
[5.50]
Bottom View
Dimensions in millimeters [inches]
32
12.7 [0.50]
1503E
2300 V, 600 A
501.2 [19.73]
309.8 [12.20]
88.9
[3.50]
461.4 [18.17]
98.6
[3.88]
125.3
[4.93]
444.1
[17.49]
50.8
[2.00] 102.6
[4.04]
414.2
[16.31]
50.8
[2.00]
203.3 [8.01]
Side View
Front View
3300/4160 V, 600 A
[15.54]
394.7394.7
[15.54]
203.3 [8.01]
[8.01]
203.3
88.9
[3.50]
461.4 [18.17]
98.6
[3.88]
189.8
[7.47]
50.8
[2.00]
581.3
[22.88]
205.2
[8.08]
611.2
[24.06]
50.8
[2.00]
Dimensions in mm [inches]
Front View
Side View
33
1503E
186.7 [7.35]
582.2
[22.92]
Front View
443.5 [17.46]
454.4 [17.89]
Side View
454.4 [17.89]
214.4 [8.44]
12.7 [0.50]
139.7
[5.50]
Bottom View
34
1503E
6900 V, 180/360A
399.3 [15.72]
101.8
[4.01]
212.6
[8.37]
617.0
[24.29]
50.8
[2.00]
587.1
23.11]
193.5
[7.62]
50.8
[2.00]
Front View
Side View
394.6 [15.54]
6900 V, 600 A
203.2 [8.00]
88.9
[3.50]
461.4 [18.17]
98.6
[3.88]
235.3
[9.26]
50.8
[2.00]
595.9
[23.46]
193.5
[7.52]
625.9
[24.64]
50.8
[2.00]
Dimensions in mm [inches]
Front View
Side View
35
1503E
36
Voltage ranges :
Current (Amps)
Catalog Number
180
360
180
360
600
180
360
600
180
360
600
180
360
600
1503E-PPZ1T
1503E-PPZ1A
1503E-PPAT
1503E-PPAA
1503E-PPAC
1503E-PPCT
1503E-PPCA
1503E-PPCC
1503E-PPET
1503E-PPEA
1503E-PPEC
1503E-PPKT
1503E-PPKA
1503E-PPKC
1503E
Description
The Voltage Sensing Board steps the voltage down from the system voltage to a voltage level
compatible with the SMC Flex control module. Includes mounting instructions.
79,5
[3.13]
385,0
[15.16]
290,0 [11.42]
Approximate dimensions in mm [inches]
Catalog Numbers
Description
Catalog Number
800 to 1500
1503E-VSZ1
1501 to 2,500
1503E-VSA
2,501 to 4,800
1503E-VSE
4,801 to 7,200
1503E-VSK
37
1503E
Description
Converts digital signals from the SMC Flex control module to drive the gate driver boards via fiber
optics. It also provides voltage, current and temperature feedback to the control module. Includes
mounting instructions.
Specifications
Control Voltage
Gate Drive
SCR Overtemperature
256.2 [10.09]
241.3 [9.50]
285.8
[11.25]
241.3
[9.50]
Front View
Side View
Note: Dimensions shown include mounting bracket assembly which is included with the interface board.
Catalog Number
38
Interface Board
Catalog Number
1503E-INTB
1503E
Description
The SMC Flex control module provides microprocessor controlled starting for standard three-phase,
squirrel-cage induction motors. The SMC Flex control module provides the following modes of operation
as standard:
Specifications
Control
Circuit
Power
Requirement
Electrical Ratings
Rated Operational Voltage
Rated Insulation Voltage
Rated Impulse Voltage
Dielectric Withstand
Operating Frequency
Protection Against Electric Shock
Control Module
UL/CSA/NEMA
100 to 240 VAC
NA
NA
1600 VAC
50/60 Hz
Finger safe
IEC
100 to 240 V ~
240 V ~
3000 V
2000 V ~
50/60 Hz
IP20
75 VA
240 VAC
1
3A @ 120 VAC, 1.5A @ 240 VAC
50/60 Hz
AC-15
3600/360
UL/CSA/NEMA
IEC
0C to 40C (32F to 104F)
-20C to 75C (-4F to 167F)
2000 meters (6,500 ft.)
5% to 95% (non-condensing)
2
39
1503E
240,7
[9.5]
70,5
[2.78]
127,1 [5.0]
Front View
Side View
40
Catalog Number
1503E-S1FX
1503E-B1FX
1503E
Description
Fiber optic cables connect the interface board to gate driver boards mounted on power stacks. They
are also used to connect thermistors in the power stacks to interface boards. Two lengths are available
to aid the design and manufacture of a new controller, or to retrofit into an existing enclosure. Includes
mounting instructions.
Specifications
Voltage Range
800 to 1500 V
2400 V
3300 V
4160 V
6100 V
No. of Cables
2.5 m (8.2 ft)
5.0 m (16.4 ft)
9
9
9
9
15
15
15
15
21
21
Catalog Number
800 to 2300 V
3300 to 4160 V
6900 V
800 to 2300 V
3300 to 4160 V
6900 V
1503E-25FO6
1503E-25FO12
1503E-25FO18
1503E-50FO6
1503E-50FO12
1503E-50FO18
41
1503E
MV SMC FLEX OEM KITS SMC FLEX GATE DRIVER TEST POWER SUPPLY
Gate Driver Test
Power Supply
Description
The test power supply is used to provide power for the gate driver board during commissioning and/or
troubleshooting. Includes operating instructions.
Specifications
Voltage Range
120 V AC 60 Hz
110/220 V AC 50/60 Hz
AC Power Cord
North American
(Cord supplied)
Universal
(Cord supplied by OEM)
42
Catalog Number
120 V AC, 60 Hz
Universal (requires power cord)
1503E-PSD
1503E-PSU
1503E
Description
The control panel is available for maximum flexibility. It connects to the Bulletin 1502 vacuum bypass
contactor, and the SMC Flex control module. It lets the SMC Flex control module close the contactor
once the motor is up-to-speed, and open the contactor under stop control. It is also used to control
contactors in a multiple contactor application (autotransformers, reactor starters, etc.) The control panel
connects the auxiliary contact on the contactor directly to the terminal blocks.
Specifications
Description
Control
Cable
Terminal Blocks
Wire Gauge
Specification
110/120 V AC, 50/60 Hz
3.05 m (10 ft)
Qty 27, 1492-W4
#14 AWG
128 [5.03]
229 [9.00]
240 [9.46]
Front View
Side View
Catalog Number
400 A
400 A
800 A
800 A
1503E-CE4D
1503E-CE4E
1503E-CE8D
1503E-CE8E
43
1503E
Description
Bulletin 1502 contactors are available for use as bypass contactors. They are required to bypass or
short out the SCRs once the motor is up to speed. The SMC Flex control module will control the closing
of this contactor when the auxiliary contact is programmed for the up-to-speed setting.
Bulletin 1502 contactors (fast dropout only) are used with the 800 to 6900 V AC frames and power
poles. Select the appropriate current, line voltage and control voltage to suit your application.
Note: The SCRs must be bypassed once up to speed. They are not rated for continuous duty.
Failure to bypass the SCRs will result in component failure.
400 A
Specifications
Refer to Bulletin 1502 description on page 1, and Specifications on page 2.
Selection
Refer to Bulletin 1502 selection table on page 7.
44
857
Catalog Number
Communication Option
857-3C6AAD
857-3C6AAL
857-3C6AAM
857-3C6AND
857-3C6ANL
RS485
Ethernet/Ethernet IP
IEC 61850
RS485
Ethernet/Ethernet IP
857-3C6ANM
IEC 61850
857-3C6AED
RS485
857-3C6AEL
Ethernet/Ethernet IP
857-3C6AEM
IEC 61850
Supports Modbus
Accessories
Description
12-channel RTD Input module (single fiber)
12-channel RTD Input module (dual fiber)
c/w 4 x 4-20 mA Input/Outputs
Programming cable for SetPoint PS
3-meter Fiber optic cable
Catalog Number
857-RAA
857-RAD
857-VX003-3
80026-385-03
45
865
Catalog Number
Communication Option
865-5A7ADE
865-5A7AHE
865-5A7AKE
RS485
Ethernet/Ethernet IP
IEC 61850
Supports Modbus
Accessories
Description
Programming cable for SetPoint PS
Catalog Number
857-VX003-3
46
Appendix A
Y
Horsepower
Rating
100
125
150
175
200
225
250
300
350
400
450
500
600
700
750
800
900
1000
1250
1500
1750
2000
2250
2500
2750
3000
3500
4000
4500
5000
5500
6000
7000
8000
9000
10000
2300V
23
29
34
40
46
52
57
68
80
91
103
113
134
158
169
177
202
216
273
326
376
434
485
537
591
647
750
857
964
1071
1179
1286
1500
1714
1929
2143
3300V
16
20
24
28
32
36
40
48
56
64
72
79
94
110
118
124
141
151
190
227
262
303
338
375
412
451
523
597
672
747
821
896
1046
1195
1344
1494
6600V
8
10
12
14
16
18
20
24
28
32
36
39
47
55
59
62
70
75
95
114
131
151
169
187
206
226
261
299
336
373
411
448
523
597
672
747
6900V
8
10
11
13
15
17
19
23
27
30
34
38
45
53
56
59
67
72
91
109
125
145
162
179
197
216
250
286
321
357
393
429
500
571
643
714
47
48
Appendix B
Y
Contactor Return
Spring
Plating Color
(400 A only)
0 to 1,000 m
(0 to 3,300 ft)
1,001 to 2,000 m
(3,301 to 6,600 ft)
400 A
600 A
800 A
Reduce B.I.L.
Withstand Rating
by:
Bronze-chromate
Green
5A
10 A
15 A
20 A
6.0 kV
2,001 to 3,000 m
(6,601 to 9,900 ft)
Blue
10 A
20 A
30 A
40 A
12.0 kV
3,001 to 4,000 m
(9,901 to 13,200 ft)
Black
15 A
30 A
45 A
60 A
18.0 kV
4,001 to 5,000 m
(13,201 to 16,500 ft)
Olive
20 A
40 A
60 A
80 A
24.0 kV
Altitude Derating
49
50
Appendix C
Y
Voltage Ranges
Nominal Line Voltage
Voltage Range
1000 V
800 to 1449 V
2400 V
1450 to 2499 V
3300 / 4160 V
2500 to 4799 V
5500 / 6900 V
4800 to 7200 V
For voltage ranges other than those listed, contact Rockwell Automation see back cover.