OBSERVATION ON CIVIL ENGINEERING STANDARD METHOD OF M
A 1 2
6 7
B 1 2
3 C 1
3 D 1 2
OBSERVATION ON CIVIL ENGINEERING STANDARD METHOD OF MEASURE
Earthwork How to estimate leads and lifts of disposal? The standard should differentiate (the earthwork done in a) Work under water b) Earthwork under foul situation c) Work under tidal condition d) Work under snow Special pumping for dewatering needs to be mentioned. The rate of pumping required needs to be standardised. The measuring unit Classification of soil should be based upon the method of excavation and not on mere nomenclature Minimum prescribed distance from where the excavation should be commenced should be mentioned based on geotechnical report. Working space beyond the face of the foundation should be specified for each type of structure. Kindly provide the standard for Dewatering technique to be adopted at the place where any structural element will be resting. How to evaluate this kind of work RCC and PCC works How to take measurements for estimating columns and beams in diagrams? While doing blinding concrete over rocky surface special regulation needs to be standardised inorder to prevent the contractor from overexcavating the rock and filling more blinding concrete than required Class F M1 related to grooves throats, fillets, chamfers or internal splays each should not exceed 40cm2 not 0.01m2 in c/s area FORM WORKS The description of formwork has to be mentioned in the definitions col likewise, What are the components included in while doing formworks .The following components should be included supports, struts, braces, wedges, bolts, wire ties, clamps, spreader, scaffolds, laddes and gangways. Oil dressing in the surface of the formwork to prevent adhesion needs to be specifically mentioned. "Formworks shall not be measured for the following edge of blinding concrete not exceeding 0,2m. Generally we used to give 0,1m thickness. To the maximum, we provide 0,15m for water retaining structures. It wooud have been better to change the thickness as 0,2m instead of 0,15m Kindly add the clause, formworks should be measured seperately for slab thickness less than 200m and for slabs greater than 200mm REINFORCEMENT BARS The measurement of spacer bars to be mentioned in the book as it may help to estimate the steel which the contractor has used for his necessary works. Kindly guide how to estimate the supporting bars and tie bars for the vertical
erection of the reinforcement cage and for shuttering.
OD OF MEASUREMENT CESMM4 Clause No. Class E: Earth works Class E Earth works