F-1
FOOTING CODE
BUILDING NAME
EMO
461 KN
121 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
500 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 121*10^3
461*1.10
=
239
mm
Assuming
461*1.10
121
BL
1434
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.997 m
2.223 m
-0.800 m
or
or
or
#VALUE! m
#VALUE! m
1.814445 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2000 mm
L=
2000 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
115.3
206.0 KN/m2
115.3
90.8
90.8
24.5 KN/m2
= 171.96875
qu =
184
=
Vu1 =
90.8 * {(750-d)/2}/1000
0.045375 d
KN/m2
( assuming d =
255
mm )
0.184 N/mm2
0.184 * 2000 * (750-d)
275309
Assuming
Vuc =
c =
367.07875 d
0.36 Mpa for
0.36 * 2000 * d =
181703.92
M25
concrete with nominal Pt =
(IS:456, Table 19)
720 d
0.25
183600
115.3 KN/m2
0.115 N/mm2
255
mm
Vu2 = 411812.125 N
For two-way shear resistance, limiting shear stress of concrete
cz =
where Ks=
0.5 + 300/500
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (500 + d)] * 2 * d
d=
Vuc =
=
404 mm
1624080 N
1624
KN
Vuc
>
Vu2
1624
411.812125 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
D >=
Provide D
50
mm
255
mm
12 mm
311 mm
=
350 mm
350 - 50 - 6
294
mm
294 - 12
282
mm
24
18
461 / (2 * 2 ) +
115.25
238.25
OUTCOME
KN/m2
KN/m2
121 * 6 / (2 * 2 ^2)
90.75
250 KN/m2
kN/m2 <
750
R = Mu/bdx2
25523437.5
103.11 kN-m
0.596471848 MPa
mm
at face of column
at footing edge
0.00141111
0.25
>
0.141
1470 mm2
Using
12
=
=
1470 / 113
14
Spacing = 146.153846 mm
Provide
14 Nos OF
ok
750
mm
0.2060 ) /2
Nmm
R = Mu/bdy2
0.729663765 MPa
0.0017379
840 mm2
Using
<
12
980.177372 mm2
=
=
Spacing =
980 / 113
9
237.5 mm
Provide
9 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2000
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
14 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
9 Nos
WITH SPACING
1.5 m
F-1
Column
B =
L
=
Fck =
Fe =
2000
mm
D=
350
L=
bars at uniform spacing in the long direction
140 mm
B=
12 bars at uniform spacing in the long direction
230 mm
300 mm
500 mm
25
500
mm
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
741 KN
134 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
500 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 134*10^3
741*1.10
=
164
mm
Assuming
741*1.10
134
BL
984
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
4.054 m
2.910 m
-0.692 m
or
or
or
#VALUE! m
#VALUE! m
2.322544 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2250 mm
L=
2250 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
146.4
217.0 KN/m2
146.4
70.6
70.6
75.8 KN/m2
= 189.505258
qu =
200
=
Vu1 =
70.6 * {(875-d)/2}/1125
0.031370828 d
KN/m2
( assuming d =
320
mm )
0.200 N/mm2
0.2 * 2250 * (875-d)
392852
Assuming
Vuc =
c =
448.9738272 d
0.36 Mpa for
0.36 * 2250 * d =
249180.38
M25
concrete with nominal Pt =
(IS:456, Table 19)
810 d
0.25
259200
146.4 KN/m2
0.146 N/mm2
320
Vu2 =
mm
664898.6 N
where Ks=
0.5 + 300/500
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (500 + d)] * 2 * d
d=
Vuc =
=
404 mm
1624080 N
1624
KN
Vuc
>
Vu2
1624
664.8986 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
D >=
Provide D
50
mm
320
mm
16 mm
378 mm
=
400 mm
400 - 50 - 8
342
mm
342 - 16
326
mm
24
18
146.3703704
249.2047325
OUTCOME
KN/m2
KN/m2
70.58436
250 KN/m2
kN/m2 <
875
R = Mu/bdx2
mm
at face of column
at footing edge
+
31524005.49
171.11 kN-m
0.650179961 MPa
0.00154234
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.154
1923.75 mm2
Using
16
=
=
1923.75 / 201
10
Spacing = 238.888889 mm
Provide
10 Nos OF
875
mm
0.2170 ) /2
Nmm
R = Mu/bdy2
0.81247395 MPa
0.00194341
1080 mm2
Using
<
16
1425.49478 mm2
=
=
1425 / 201
8
Spacing = 307.142857 mm
Provide
8 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2250
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
10 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
8 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2250
mm
D=
400
L=
bars at uniform spacing in the long direction
230 mm
B=
16 bars at uniform spacing in the long direction
300 mm
300 mm
500 mm
25
500
mm
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
996 KN
148 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 148*10^3
996*1.10
=
135
mm
Assuming
996*1.10
810
148
BL
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
5.081 m
3.583 m
-0.630 m
or
or
or
3.308947 m
#VALUE! m
2.820807 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2500 mm
L=
2500 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
159.4
216.2 KN/m2
159.4
102.5 KN/m2
56.8
56.8
= 192.89088
qu =
201
=
Vu1 =
56.8 * {(1025-d)/2}/1250
0.0227328 d
KN/m2
( assuming d =
370
mm )
0.201 N/mm2
0.201 * 2500 * (1025-d)
515836
Assuming
Vuc =
c =
503.25504 d
0.36 Mpa for
0.36 * 2500 * d =
329631.64
M25
concrete with nominal Pt =
(IS:456, Table 19)
900 d
0.25
333000
159.4 KN/m2
0.159 N/mm2
370
Vu2 =
mm
906395.4 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
906.3954 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
D >=
Provide D
50
mm
370
mm
16 mm
428 mm
=
450 mm
450 - 50 - 8
392
mm
392 - 16
376
mm
24
18
159.36
248.442
OUTCOME
KN/m2
KN/m2
56.832
250 KN/m2
kN/m2 <
1025
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.216 -0.17 ) * (1/2) *2500 * 1025 ^2 * 2/3
40801232
263.52 kN-m
0.685964921 MPa
0.00163018
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.163
2450 mm2
Using
16
=
=
Spacing =
2450 / 201
13
200 mm
Provide
13 Nos OF
1025
mm
0.2162 ) /2
Nmm
R = Mu/bdy2
0.803562698 MPa
0.00192121
1350 mm2
Using
<
16
1805.93903 mm2
=
=
Spacing =
1806 / 201
9
300 mm
Provide
9 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2500
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
13 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
9 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2500
mm
D=
450
L=
bars at uniform spacing in the long direction
200 mm
B=
16 bars at uniform spacing in the long direction
300 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
87
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
748 KN
Mux
108 kN-m
FULL MXz
qa
250 KN/m2
DEPTH OF FOUNDATION =
Column
B =
135 kN-m
L
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 108*10^3
748*1.10
=
131
mm
Assuming
748*1.10
786
108
BL
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
3.948 m
2.809 m
-0.582 m
or
or
or
1.986187 m
#VALUE! m
2.227435 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2250 mm
L=
2250 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
147.8
204.6 KN/m2
147.8
56.9
56.9
90.9 KN/m2
204.6
= 181.88642
=
190
=
Vu1 =
56.9 * {(900-d)/2}/1125
0.025283951 d
KN/m2
( assuming d =
330
mm )
0.190 N/mm2
0.19 * 2250 * (900-d)
385216
Assuming
Vuc =
c =
428.0177778 d
0.36 Mpa for
0.36 * 2250 * d =
243970.13
M25
concrete with nominal Pt =
(IS:456, Table 19)
810 d
0.25
267300
147.8 KN/m2
0.148 N/mm2
330
Vu2 =
mm
676522.8 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
676.5228 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
D >=
Provide D
50
mm
330
mm
16 mm
388 mm
=
400 mm
400 - 50 - 8
342
mm
342 - 16
326
mm
24
18
147.7530864
236.8919753
OUTCOME
KN/m2
KN/m2
56.88889
250 KN/m2
kN/m2 <
900
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.205 -0.159 ) * (1/2) *2250 * 900 ^2 * 2/3
27648000
172.66 kN-m
0.656065114 MPa
0.00155676
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.156
1923.75 mm2
Using
16
=
=
1923.75 / 201
10
Spacing = 238.888889 mm
Provide
10 Nos OF
900
mm
0.2046 ) /2
Nmm
R = Mu/bdy2
0.788032001 MPa
0.00188257
1080 mm2
Using
<
16
1380.86269 mm2
=
=
1381 / 201
7
Spacing = 358.333333 mm
Provide
7 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2250
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
10 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
7 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2250
mm
D=
400
L=
bars at uniform spacing in the long direction
230 mm
B=
16 bars at uniform spacing in the long direction
350 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
88
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
386 KN
118 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 118*10^3
386*1.10
Footing result
Lf
2000
Bf
2100
thickness Df
=
278
mm
Assuming
386*1.10
118
BL
1668
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.734 m
2.052 m
-0.839 m
or
or
or
#VALUE! m
#VALUE! m
1.688042 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2000 mm
L=
2100 mm
OUTCOME
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
91.9
=
qu,min =
80.3
172.2 KN/m2
91.9
11.6 KN/m2
80.3
172.2
= 140.641399
=
150
=
Vu1 =
80.3 * {(825-d)/2}/1050
0.038224814 d
KN/m2
( assuming d =
250
mm )
0.150 N/mm2
0.15 * 2000 * (825-d)
247826
Assuming
Vuc =
c =
300.3952057 d
0.36 Mpa for
0.36 * 2000 * d =
172727.2
M25
concrete with nominal Pt =
(IS:456, Table 19)
720 d
0.25
180000
91.9 KN/m2
0.092 N/mm2
250
Vu2 =
mm
350980 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
350.98 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
250
50
mm
320 - 50 - 8
262
mm
262 - 16
246
mm
D >=
Provide D
mm
16 mm
308 mm
=
320 mm
24
18
386 / (2 * 2.1 ) +
91.9047619
204.4268707
OUTCOME
KN/m2
KN/m2
80.27211
250 KN/m2
kN/m2 <
825
R = Mu/bdx2
mm
at face of column
at footing edge
+
28618440.23
102.88 kN-m
0.749363838 MPa
0.00178663
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.179
1310 mm2
Using
16
=
=
1310 / 201
7
Spacing = 333.333333 mm
Provide
7 Nos OF
825
mm
0.1722 ) /2
Nmm
R = Mu/bdy2
0.788217081 MPa
0.00188303
806.4 mm2
Using
<
16
972.771683 mm2
=
=
Spacing =
973 / 201
5
475 mm
Provide
5 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2000
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
7 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
5 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2100
mm
D=
320
L=
bars at uniform spacing in the long direction
330 mm
B=
16 bars at uniform spacing in the long direction
470 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
89
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
666 KN
133 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 133*10^3
666*1.10
Footing result
Lf
2200
Bf
2200
thickness Df
=
182
mm
Assuming
666*1.10
133
BL
1092
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.732 m
2.009 m
-0.653 m
or
or
or
#VALUE! m
#VALUE! m
1.629686 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2200 mm
L=
2200 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
137.6
212.5 KN/m2
137.6
74.9
74.9
62.7 KN/m2
212.5
= 182.739823
=
193
=
Vu1 =
74.9 * {(875-d)/2}/1100
0.034065296 d
KN/m2
( assuming d =
310
mm )
0.193 N/mm2
0.193 * 2200 * (875-d)
372103
Assuming
Vuc =
c =
425.2601427 d
0.36 Mpa for
0.36 * 2200 * d =
240272.36
M25
concrete with nominal Pt =
(IS:456, Table 19)
792 d
0.25
245520
137.6 KN/m2
0.138 N/mm2
310
Vu2 =
mm
603943.2 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
603.9432 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
310
50
mm
380 - 50 - 8
322
mm
322 - 16
306
mm
D >=
Provide D
mm
16 mm
368 mm
=
380 mm
24
18
137.6033058
244.7969572
OUTCOME
KN/m2
KN/m2
74.94365
250 KN/m2
kN/m2 <
875
R = Mu/bdx2
mm
at face of column
at footing edge
+
33470927.64
162.27 kN-m
0.711378834 MPa
0.00169277
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.169
1771 mm2
Using
16
=
=
Spacing =
1771 / 201
9
262.5 mm
Provide
9 Nos OF
875
mm
0.2125 ) /2
Nmm
R = Mu/bdy2
0.843720931 MPa
0.00202144
1003.2 mm2
Using
<
16
1360.83254 mm2
=
=
Spacing =
1361 / 201
7
350 mm
Provide
7 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2200
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
9 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
7 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2200
mm
D=
380
L=
bars at uniform spacing in the long direction
260 mm
B=
16 bars at uniform spacing in the long direction
350 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
90
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
969 KN
147 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 147*10^3
969*1.10
Footing result
Lf
2500
Bf
2500
thickness Df
=
138
mm
Assuming
969*1.10
828
147
BL
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
4.973 m
3.512 m
-0.637 m
or
or
or
3.140052 m
#VALUE! m
2.768881 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2500 mm
L=
2500 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
155.0
211.5 KN/m2
155.0
56.4
56.4
98.6 KN/m2
211.5
= 188.34432
=
197
=
Vu1 =
56.4 * {(1025-d)/2}/1250
0.0225792 d
KN/m2
( assuming d =
370
mm )
0.197 N/mm2
0.197 * 2500 * (1025-d)
504040
Assuming
Vuc =
c =
491.74656 d
0.36 Mpa for
0.36 * 2500 * d =
322093.77
M25
concrete with nominal Pt =
(IS:456, Table 19)
900 d
0.25
333000
155.0 KN/m2
0.155 N/mm2
370
Vu2 =
mm
883593 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
883.593 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
370
50
mm
450 - 50 - 8
392
mm
392 - 16
376
mm
D >=
Provide D
mm
16 mm
428 mm
=
450 mm
24
18
155.04
243.738
OUTCOME
KN/m2
KN/m2
56.448
250 KN/m2
kN/m2 <
1025
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.211 -0.165 ) * (1/2) *2500 * 1025 ^2 * 2/3
40525548
257.48 kN-m
0.67024274 MPa
0.00159155
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.159
2450 mm2
Using
16
=
=
Spacing =
2450 / 201
13
200 mm
Provide
13 Nos OF
1025
mm
0.2115 ) /2
Nmm
R = Mu/bdy2
0.784254187 MPa
0.00187318
1350 mm2
Using
<
16
1760.78559 mm2
=
=
Spacing =
1761 / 201
9
300 mm
Provide
9 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2500
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
13 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
9 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2500
mm
D=
450
L=
bars at uniform spacing in the long direction
200 mm
B=
16 bars at uniform spacing in the long direction
300 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
110
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
980 KN
150 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 150*10^3
980*1.10
Footing result
Lf
2500
Bf
2500
thickness Df
=
139
mm
Assuming
980*1.10
834
150
BL
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
3.551 m
2.545 m
-0.591 m
or
or
or
#VALUE! m
#VALUE! m
2.028812 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2500 mm
L=
2500 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
156.8
214.4 KN/m2
156.8
57.6
57.6
99.2 KN/m2
214.4
190.784
199
=
Vu1 =
57.6 * {(1025-d)/2}/1250
0.02304 d
KN/m2
( assuming d =
370
mm )
0.199 N/mm2
0.199 * 2500 * (1025-d)
510729
Assuming
Vuc =
498.272 d
c =
0.36 * 2500 * d =
326368.36
M25
concrete with nominal Pt =
(IS:456, Table 19)
900 d
0.25
333000
156.8 KN/m2
0.157 N/mm2
370
Vu2 =
mm
894994.2 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
894.9942 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
370
50
mm
450 - 50 - 8
392
mm
392 - 16
376
mm
D >=
Provide D
mm
16 mm
428 mm
=
450 mm
24
18
156.8
246.65
OUTCOME
KN/m2
KN/m2
57.6
250 KN/m2
kN/m2 <
1025
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.214 -0.167 ) * (1/2) *2500 * 1025 ^2 * 2/3
41352600
260.89 kN-m
0.6791212 MPa
0.00161336
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.161
2450 mm2
Using
16
=
=
Spacing =
2450 / 201
13
200 mm
Provide
13 Nos OF
1025
mm
0.2144 ) /2
Nmm
R = Mu/bdy2
0.794250792 MPa
0.00189803
1350 mm2
Using
<
16
1784.15118 mm2
=
=
Spacing =
1784 / 201
9
300 mm
Provide
9 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2500
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
13 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
9 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2500
mm
D=
450
L=
bars at uniform spacing in the long direction
200 mm
B=
16 bars at uniform spacing in the long direction
300 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
91
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
Column
B =
L
=
1080 KN
147 KNm
qa
250 KN/m2
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 147*10^3
1080*1.10
Footing result
Lf
2600
Bf
2600
thickness Df
=
124
mm
Assuming
1080*1.10
147
BL
744
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
3.789 m
2.694 m
-0.551 m
or
or
or
1.980303 m
#VALUE! m
2.134857 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2600 mm
L=
2600 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
159.8
209.9 KN/m2
159.8
109.6 KN/m2
50.2
50.2
209.9
= 189.197026
=
197
=
Vu1 =
50.2 * {(1075-d)/2}/1300
0.019300795 d
KN/m2
( assuming d =
380
mm )
0.197 N/mm2
0.197 * 2600 * (1075-d)
549305
Assuming
Vuc =
c =
510.981452 d
0.36 Mpa for
0.36 * 2600 * d =
355132
M25
concrete with nominal Pt =
(IS:456, Table 19)
936 d
0.25
355680
159.8 KN/m2
0.16 N/mm2
380
Vu2 =
mm
991296 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
991.296 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
380
50
mm
450 - 50 - 8
392
mm
392 - 16
376
mm
D >=
Provide D
mm
16 mm
438 mm
=
450 mm
24
18
159.7633136
242.1953801
OUTCOME
KN/m2
KN/m2
50.18207
250 KN/m2
kN/m2 <
1075
R = Mu/bdx2
mm
at face of column
at footing edge
+
41560682.89
294.62 kN-m
0.737431187 MPa
0.0017571
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.176
2548 mm2
Using
16
=
=
2548 / 201
13
Spacing = 208.333333 mm
Provide
13 Nos OF
1075
mm
0.2099 ) /2
Nmm
R = Mu/bdy2
0.864608822 MPa
0.00207374
2027.2921 mm2
1404 mm2
Using
<
16
2027.2921 mm2
=
=
Spacing =
2027 / 201
11
250 mm
Provide
11 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2600
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
13 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
11 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2600
mm
D=
450
L=
bars at uniform spacing in the long direction
200 mm
B=
16 bars at uniform spacing in the long direction
250 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
92
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
Column
B =
L
=
1333 KN
150 KNm
qa
250 KN/m2
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 150*10^3
1333*1.10
=
102
mm
Assuming
1333*1.10
150
BL
612
<=
mm )
250 * 1
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
6.425 m
4.450 m
-0.521 m
or
or
or
5.1687 m
3.147663 m
3.45377 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2800 mm
L=
2800 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
170.0
211.0 KN/m2
170.0
129.0 KN/m2
41.0
41.0
= 193.819307
qu =
200
=
Vu1 =
41 * {(1175-d)/2}/1400
0.014642337 d
KN/m2
( assuming d =
430
mm )
0.200 N/mm2
0.2 * 2800 * (1175-d)
658380
Assuming
Vuc =
c =
560.3234329 d
0.36 Mpa for
0.36 * 2800 * d =
417440.92
M25
concrete with nominal Pt =
(IS:456, Table 19)
1008 d
0.25
433440
170.0 KN/m2
0.17 N/mm2
430
Vu2 =
mm
1223592 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
1223.592 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
D >=
Provide D
50
mm
430
mm
16 mm
488 mm
=
500 mm
500 - 50 - 8
442
mm
442 - 16
426
mm
24
18
170.0255102
243.2740525
OUTCOME
KN/m2
KN/m2
40.99854
250 KN/m2
kN/m2 <
1175
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.211 -0.177 ) * (1/2) *2800 * 1175 ^2 * 2/3
44339496.4
385.71 kN-m
0.705118517 MPa
0.00167734
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.168
3094 mm2
Using
16
=
=
Spacing =
3094 / 201
16
180 mm
Provide
16 Nos OF
1175
mm
0.2110 ) /2
Nmm
R = Mu/bdy2
0.820204795 MPa
0.00196269
1680 mm2
Using
<
16
2341.10163 mm2
=
=
2341 / 201
12
Spacing = 245.454545 mm
Provide
12 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2800
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
16 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
12 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2800
mm
D=
500
L=
bars at uniform spacing in the long direction
180 mm
B=
16 bars at uniform spacing in the long direction
240 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
93
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
Column
B =
L
=
1083 KN
147 KNm
qa
250 KN/m2
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 147*10^3
1083*1.10
Footing result
Lf
2600
Bf
2600
thickness Df
=
123
mm
Assuming
1083*1.10
147
BL
738
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
3.796 m
2.699 m
-0.550 m
or
or
or
2.001939 m
#VALUE! m
2.138355 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2600 mm
L=
2600 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
160.2
210.4 KN/m2
160.2
110.0 KN/m2
50.2
50.2
210.4
= 189.640813
=
197
=
Vu1 =
50.2 * {(1075-d)/2}/1300
0.019300795 d
KN/m2
( assuming d =
390
mm )
0.197 N/mm2
0.197 * 2600 * (1075-d)
551085
Assuming
Vuc =
c =
512.6371188 d
0.36 Mpa for
0.36 * 2600 * d =
351156.52
M25
concrete with nominal Pt =
(IS:456, Table 19)
936 d
0.25
365040
160.2 KN/m2
0.16 N/mm2
390
Vu2 =
mm
988864 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
988.864 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
390
50
mm
450 - 50 - 8
392
mm
392 - 16
376
mm
D >=
Provide D
mm
16 mm
448 mm
=
450 mm
24
18
160.2071006
242.639167
OUTCOME
KN/m2
KN/m2
50.18207
250 KN/m2
kN/m2 <
1075
R = Mu/bdx2
mm
at face of column
at footing edge
+
41560682.89
295.29 kN-m
0.739099929 MPa
0.00176123
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.176
2548 mm2
Using
16
=
=
2548 / 201
13
Spacing = 208.333333 mm
Provide
13 Nos OF
1075
mm
0.2104 ) /2
Nmm
R = Mu/bdy2
0.866684522 MPa
0.00207895
1404 mm2
Using
<
16
2032.37979 mm2
=
=
Spacing =
2032 / 201
11
250 mm
Provide
11 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2600
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
13 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
11 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2600
mm
D=
450
L=
bars at uniform spacing in the long direction
200 mm
B=
16 bars at uniform spacing in the long direction
250 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
94
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
551 KN
129 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 129*10^3
551*1.10
Footing result
Lf
2100
Bf
2100
thickness Df
=
213
mm
Assuming
551*1.10
129
BL
1278
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.456 m
1.830 m
-0.689 m
or
or
or
#VALUE! m
#VALUE! m
1.497351 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2100 mm
L=
2100 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
124.9
208.5 KN/m2
124.9
83.6
83.6
41.4 KN/m2
208.5
= 175.686057
=
187
=
Vu1 =
83.6 * {(825-d)/2}/1050
0.039798232 d
KN/m2
( assuming d =
290
mm )
0.187 N/mm2
0.187 * 2100 * (825-d)
324372
Assuming
Vuc =
c =
393.1778426 d
0.36 Mpa for
0.36 * 2100 * d =
210350.43
M25
concrete with nominal Pt =
(IS:456, Table 19)
756 d
0.25
219240
124.9 KN/m2
0.125 N/mm2
290
Vu2 =
mm
496675 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
496.675 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
290
50
mm
350 - 50 - 8
292
mm
292 - 16
276
mm
D >=
Provide D
mm
16 mm
348 mm
=
350 mm
24
18
124.9433107
240.7695983
OUTCOME
KN/m2
KN/m2
83.57629
250 KN/m2
kN/m2 <
825
R = Mu/bdx2
mm
at face of column
at footing edge
+
31286260.93
133.38 kN-m
0.744894868 MPa
0.00177557
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.178
1533 mm2
Using
16
=
=
1533 / 201
8
Spacing = 285.714286 mm
Provide
8 Nos OF
825
mm
0.2085 ) /2
Nmm
R = Mu/bdy2
0.886450313 MPa
0.00212857
882 mm2
Using
<
16
1233.71631 mm2
=
=
1234 / 201
7
Spacing = 333.333333 mm
Provide
7 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2100
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
8 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
7 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2100
mm
D=
350
L=
bars at uniform spacing in the long direction
280 mm
B=
16 bars at uniform spacing in the long direction
330 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
95
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
430 KN
138 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 138*10^3
430*1.10
Footing result
Lf
2000
Bf
2000
thickness Df
=
292
mm
Assuming
430*1.10
138
BL
1752
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.245 m
1.704 m
-0.782 m
or
or
or
#VALUE! m
#VALUE! m
1.412345 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2000 mm
L=
2000 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
107.5
211.0 KN/m2
107.5
103.5
103.5
4.0 KN/m2
211.0
= 170.89375
=
185
=
Vu1 =
103.5 * {(775-d)/2}/1000
0.05175 d
KN/m2
( assuming d =
270
mm )
0.185 N/mm2
0.185 * 2000 * (775-d)
286543
Assuming
Vuc =
369.7325 d
c =
0.36 * 2000 * d =
186715.23
M25
concrete with nominal Pt =
(IS:456, Table 19)
720 d
0.25
194400
107.5 KN/m2
0.108 N/mm2
270
Vu2 =
mm
387676.8 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
387.6768 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
270
50
mm
350 - 50 - 6
294
mm
294 - 12
282
mm
D >=
Provide D
mm
12 mm
326 mm
=
350 mm
24
18
430 / (2 * 2 ) +
107.5
243.25
OUTCOME
KN/m2
KN/m2
138 * 6 / (2 * 2 ^2)
103.5
250 KN/m2
kN/m2 <
775
R = Mu/bdx2
mm
at face of column
at footing edge
+
32118421.88
110.67 kN-m
0.640200056 MPa
0.0015179
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.152
1470 mm2
Using
12
=
=
1470 / 113
14
Spacing = 146.153846 mm
Provide
14 Nos OF
775
mm
0.2110 ) /2
Nmm
R = Mu/bdy2
0.723417616 MPa
0.00172248
840 mm2
Using
<
12
971.476204 mm2
=
=
Spacing =
971 / 113
9
237.5 mm
Provide
9 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2000
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
14 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
9 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2000
mm
D=
350
L=
bars at uniform spacing in the long direction
140 mm
B=
12 bars at uniform spacing in the long direction
230 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
96
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Column
B =
315 kN
Mu(RDM)
FULL MXz
111.6 kN-m
qa
250 KN/m2
124 kN-m
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 111.6*10^3
315*1.10
Footing result
Lf
2000
Bf
2000
thickness Df
=
322
mm
Assuming
315*1.10
1932
111.6
BL
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
1.876 m
1.442 m
-0.742 m
or
or
or
#VALUE! m
#VALUE! m
1.203708 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2000 mm
L=
2000 mm
OUTCOME
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
78.8
=
qu,min =
83.7
162.5 KN/m2
78.8
-5.0 KN/m2
83.7
162.5
= 130.01625
=
140
=
Vu1 =
83.7 * {(775-d)/2}/1000
0.04185 d
KN/m2
( assuming d =
240
mm )
0.140 N/mm2
0.14 * 2000 * (775-d)
217093
Assuming
Vuc =
280.1205 d
c =
0.36 * 2000 * d =
149864.08
M25
concrete with nominal Pt =
(IS:456, Table 19)
720 d
0.25
172800
78.8 KN/m2
0.079 N/mm2
240
Vu2 =
mm
286564.6 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
286.5646 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
240
50
mm
300 - 50 - 6
244
mm
244 - 12
232
mm
D >=
Provide D
mm
12 mm
296 mm
=
300 mm
24
18
315 / (2 * 2 ) +
78.75
194.7
OUTCOME
KN/m2
KN/m2
111.6 * 6 / (2 * 2 ^2)
83.7
250 KN/m2
kN/m2 <
775
R = Mu/bdx2
mm
at face of column
at footing edge
+
25974028.13
84.58 kN-m
0.710364462 MPa
0.00169027
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.169
1220 mm2
Using
12
=
=
Spacing =
1220 / 113
11
190 mm
Provide
11 Nos OF
775
mm
0.1625 ) /2
Nmm
R = Mu/bdy2
0.809429808 MPa
0.00193583
720 mm2
Using
<
12
898.224056 mm2
=
=
898 / 113
8
Spacing = 271.428571 mm
Provide
8 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2000
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
11 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
8 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2000
mm
D=
300
L=
bars at uniform spacing in the long direction
190 mm
B=
12 bars at uniform spacing in the long direction
270 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
97
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
498 KN
139 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 139*10^3
498*1.10
Footing result
Lf
2100
Bf
2100
thickness Df
=
254
mm
Assuming
498*1.10
139
BL
1524
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.391 m
1.798 m
-0.751 m
or
or
or
#VALUE! m
#VALUE! m
1.481162 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2100 mm
L=
2100 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
112.9
203.0 KN/m2
112.9
90.1
90.1
22.9 KN/m2
203.0
= 167.601462
=
180
=
Vu1 =
90.1 * {(825-d)/2}/1050
0.042883366 d
KN/m2
( assuming d =
280
mm )
0.180 N/mm2
0.18 * 2100 * (825-d)
311172
Assuming
Vuc =
c =
377.1784904 d
0.36 Mpa for
0.36 * 2100 * d =
205562
M25
concrete with nominal Pt =
(IS:456, Table 19)
756 d
0.25
211680
112.9 KN/m2
0.113 N/mm2
280
Vu2 =
mm
450485.8 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
450.4858 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
280
50
mm
350 - 50 - 8
292
mm
292 - 16
276
mm
D >=
Provide D
mm
16 mm
338 mm
=
350 mm
24
18
112.9251701
235.2302397
OUTCOME
KN/m2
KN/m2
90.05507
250 KN/m2
kN/m2 <
825
R = Mu/bdx2
mm
at face of column
at footing edge
+
33711552.48
128.21 kN-m
0.716013238 MPa
0.0017042
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.170
1533 mm2
Using
16
=
=
1533 / 201
8
Spacing = 285.714286 mm
Provide
8 Nos OF
825
mm
0.2030 ) /2
Nmm
R = Mu/bdy2
0.839776905 MPa
0.00201158
882 mm2
Using
<
16
1165.90936 mm2
=
=
Spacing =
1166 / 201
6
400 mm
Provide
6 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2100
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
8 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
6 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2100
mm
D=
350
L=
bars at uniform spacing in the long direction
280 mm
B=
16 bars at uniform spacing in the long direction
400 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
98
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
582 KN
138 KNm
qa
250 KN/m2
Column
B =
L
=
DEPTH OF FOUNDATION =
1.5 m
300 mm
450 mm
Fck =
Fe =
25
500
10 % of Pu,
e = 138*10^3
582*1.10
Footing result
Lf
2200
Bf
2200
thickness Df
=
216
mm
Assuming
582*1.10
138
BL
1296
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.567 m
1.909 m
-0.707 m
or
or
or
#VALUE! m
#VALUE! m
1.560889 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2200 mm
L=
2200 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
120.2
198.0 KN/m2
120.2
77.8
77.8
42.5 KN/m2
198.0
= 167.081313
=
177
=
Vu1 =
77.8 * {(875-d)/2}/1100
0.035345946 d
KN/m2
( assuming d =
290
mm )
0.177 N/mm2
0.177 * 2200 * (875-d)
341363
Assuming
Vuc =
c =
390.1296018 d
0.36 Mpa for
0.36 * 2200 * d =
228225.42
M25
concrete with nominal Pt =
(IS:456, Table 19)
792 d
0.25
229680
120.2 KN/m2
0.12 N/mm2
290
Vu2 =
mm
528408 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
528.408 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
290
50
mm
350 - 50 - 8
292
mm
292 - 16
276
mm
D >=
Provide D
mm
16 mm
348 mm
=
350 mm
24
18
120.2479339
230.2590158
OUTCOME
KN/m2
KN/m2
77.76108
250 KN/m2
kN/m2 <
875
R = Mu/bdx2
mm
at face of column
at footing edge
+
34729233.19
149.40 kN-m
0.796435997 MPa
0.00190347
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.190
1606 mm2
Using
16
=
=
Spacing =
1606 / 201
8
300 mm
Provide
8 Nos OF
875
mm
0.1980 ) /2
Nmm
R = Mu/bdy2
0.942642358 MPa
0.00227021
924 mm2
Using
<
16
1378.47275 mm2
=
=
Spacing =
1378 / 201
7
350 mm
Provide
7 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2200
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
8 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
7 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2200
mm
D=
350
L=
bars at uniform spacing in the long direction
300 mm
B=
16 bars at uniform spacing in the long direction
350 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
99
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
Mux
477 KN
136 KNm
qa
250 KN/m2
DEPTH OF FOUNDATION =
1.5 m
Column
B =
L
=
300
450
Fck =
Fe =
25
500
mm
mm
10 % of Pu,
e = 136*10^3
477*1.10
Footing result
Lf
2100
Bf
2100
thickness Df
=
259
mm
Assuming
477*1.10
1554
136
BL
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
2.332 m
1.758 m
-0.750 m
or
or
or
#VALUE! m
#VALUE! m
1.449964 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2100 mm
L=
2100 mm
OUTCOME
qu,min =
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
108.2
196.3 KN/m2
108.2
88.1
88.1
20.1 KN/m2
196.3
= 161.659494
=
173
=
Vu1 =
88.1 * {(825-d)/2}/1050
0.041957826 d
KN/m2
( assuming d =
270
mm )
0.173 N/mm2
0.173 * 2100 * (825-d)
299702
Assuming
Vuc =
c =
363.2750243 d
0.36 Mpa for
0.36 * 2100 * d =
201617.74
M25
concrete with nominal Pt =
(IS:456, Table 19)
756 d
0.25
204120
108.2 KN/m2
0.108 N/mm2
270
Vu2 =
mm
431956.8 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
431.9568 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
270
50
mm
350 - 50 - 8
292
mm
292 - 16
276
mm
D >=
Provide D
mm
16 mm
328 mm
=
350 mm
24
18
108.1632653
228.5247004
OUTCOME
KN/m2
KN/m2
88.11144
250 KN/m2
kN/m2 <
825
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.196 -0.127 ) * (1/2) *2100 * 825 ^2 * 2/3
32983965
123.78 kN-m
0.691281302 MPa
0.00164326
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.164
1533 mm2
Using
16
=
=
1533 / 201
8
Spacing = 285.714286 mm
Provide
8 Nos OF
825
mm
0.1963 ) /2
Nmm
R = Mu/bdy2
0.809292796 MPa
0.00193549
882 mm2
Using
<
16
1121.80785 mm2
=
=
Spacing =
1122 / 201
6
400 mm
Provide
6 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2100
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
8 Nos OF
16
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
6 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2100
mm
D=
350
L=
bars at uniform spacing in the long direction
280 mm
B=
16 bars at uniform spacing in the long direction
400 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
100
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
274 kN
Mux
FULL MXz
84 kN-m
qa
250 KN/m2
120 kN-m
DEPTH OF FOUNDATION =
1.5 m
Column
B =
300
mm
450
mm
Fck =
Fe =
25
500
10 % of Pu,
e = 84*10^3
274*1.10
Footing result
Lf
1800
Bf
1800
thickness Df
=
279
mm
Assuming
274*1.10
1674
84
BL
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
1.629 m
1.252 m
-0.643 m
or
or
or
#VALUE! m
#VALUE! m
1.044956 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
1800 mm
L=
1800 mm
OUTCOME
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
84.6
=
qu,min =
86.4
171.0 KN/m2
84.6
-1.9 KN/m2
86.4
171.0
= 138.580247
=
150
=
Vu1 =
86.4 * {(675-d)/2}/900
0.048010974 d
KN/m2
( assuming d =
230
mm )
0.150 N/mm2
0.15 * 1800 * (675-d)
181792
Assuming
Vuc =
c =
269.3209877 d
0.36 Mpa for
0.36 * 1800 * d =
119848.17
M25
concrete with nominal Pt =
(IS:456, Table 19)
648 d
0.25
149040
84.6 KN/m2
0.085 N/mm2
230
Vu2 =
mm
244766 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
244.766 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
230
50
mm
300 - 50 - 6
244
mm
244 - 12
232
mm
D >=
Provide D
mm
12 mm
286 mm
=
300 mm
24
18
84.56790123
203.2376543
OUTCOME
KN/m2
KN/m2
84 * 6 / (2 * 1.8 ^2)
86.41975
250 KN/m2
kN/m2 <
675
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.171 -0.106 ) * (1/2) *1800 * 675 ^2 * 2/3
17718750
61.26 kN-m
0.571607935 MPa
0.00135061
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.135
1098 mm2
Using
12
=
=
1098 / 113
10
Spacing = 188.888889 mm
Provide
10 Nos OF
675
mm
0.1710 ) /2
Nmm
R = Mu/bdy2
0.667685419 MPa
0.00158527
648 mm2
Using
<
12
662.008929 mm2
=
=
Spacing =
662 / 113
6
340 mm
Provide
6 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
1800
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
10 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
6 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
1800
mm
D=
300
L=
bars at uniform spacing in the long direction
180 mm
B=
12 bars at uniform spacing in the long direction
340 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
101
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
202 KN
Mud
FULL MXz
102.2 KNm
qa
250 KN/m2
146 kN-m
DEPTH OF FOUNDATION =
1.5 m
Column
B =
300
mm
450
mm
Fck =
Fe =
25
500
10 % of Pu,
e = 102.2*10^3
202*1.10
Footing result
Lf
2000
Bf
2000
thickness Df
=
460
mm
Assuming
202*1.10
2760
102.2
BL
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
1.609 m
1.260 m
-0.768 m
or
or
or
#VALUE! m
#VALUE! m
1.064399 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
2000 mm
L=
2000 mm
OUTCOME
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
50.5
=
qu,min =
76.7
127.2 KN/m2
50.5
76.7
-26.2 KN/m2
127.2
= 97.448125
=
105
=
Vu1 =
76.7 * {(775-d)/2}/1000
0.038325 d
KN/m2
( assuming d =
210
mm )
0.105 N/mm2
0.105 * 2000 * (775-d)
163519
Assuming
Vuc =
210.99275 d
c =
0.36 * 2000 * d =
119210.52
M25
concrete with nominal Pt =
(IS:456, Table 19)
720 d
0.25
151200
50.5 KN/m2
0.051 N/mm2
210
Vu2 =
mm
186833.4 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
186.8334 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
210
50
mm
275 - 50 - 6
219
mm
219 - 12
207
mm
D >=
Provide D
mm
12 mm
266 mm
=
275 mm
24
18
202 / (2 * 2 ) +
50.5
159.4
OUTCOME
KN/m2
KN/m2
+ 102.2 * 6 / (2 * 2 ^2)
76.65
250 KN/m2
kN/m2 <
775
R = Mu/bdx2
mm
at face of column
at footing edge
+
23786251.56
64.48 kN-m
0.672174715 MPa
0.00159629
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.160
1095 mm2
Using
12
=
=
1095 / 113
10
Spacing = 211.111111 mm
Provide
10 Nos OF
775
mm
0.1272 ) /2
Nmm
R = Mu/bdy2
0.748863013 MPa
0.00178539
660 mm2
Using
<
12
739.150754 mm2
=
=
739 / 113
7
Spacing = 316.666667 mm
Provide
7 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
2000
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
10 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
7 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
2000
mm
D=
275
L=
bars at uniform spacing in the long direction
210 mm
B=
12 bars at uniform spacing in the long direction
310 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
102
EMO
FOOTING CODE
DESIGN OF ISOLATED FOOTING
Given:
Pu
205 KN
Mux
FULL MXz
98 KNm
qa
250 KN/m2
140 kN-m
DEPTH OF FOUNDATION =
1.5 m
Column
B =
300
mm
450
mm
Fck =
Fe =
25
500
10 % of Pu,
e = 98*10^3
205*1.10
Footing result
Lf
1800
Bf
1800
thickness Df
=
435
mm
Assuming
205*1.10
98
BL
2610
<=
mm )
250 * 1.5
1.5
KN/m2
BL2/6
<=
Assuming
L>=
L>=
L>=
B=
B=
B=
1.00
1.50
2.00
m =>
m =>
m =>
0
1.588 m
1.242 m
-0.748 m
or
or
or
#VALUE! m
#VALUE! m
1.048443 m
An economical proportion of the base slab is generally one in which the projection beyond the face of column is
approximately equal in both direction
Therefore provide,
B=
1800 mm
L=
1800 mm
OUTCOME
Pu
BL
Mux
BL2/6
Pu
BL
Mux
BL2/6
63.3
=
qu,min =
100.8
164.1 KN/m2
63.3
100.8
-37.6 KN/m2
164.1
= 126.286008
=
139
=
Vu1 =
100.8 * {(675-d)/2}/900
0.0560128029 d
KN/m2
( assuming d =
220
mm )
249.49588477 d
113520.91
0.139 N/mm2
0.139 * 1800 * (675-d)
168410
Assuming
Vuc =
c =
M25
concrete with nominal Pt =
(IS:456, Table 19)
0.36 * 1800 * d =
648 d
0.25
142560
63.3 KN/m2
0.063 N/mm2
220
Vu2 =
mm
182170.8 N
where Ks=
0.5 + 300/450
but limited to
1
Ks (0.25)Fck
cz =
1.250 Mpa
Vuc = cz * b*d
= 1.25* [(300 + d) + (450 + d)] * 2 * d
d=
Vuc =
=
404 mm
1573580 N
1574
KN
Vuc
>
Vu2
1574
182.1708 provide, THICKNESS OF FOOTING IS SAFE
Hence one way shear governs the footing slab thickness and d >=
Assuming clear cover =
220
50
mm
300 - 50 - 6
244
mm
244 - 12
232
mm
D >=
Provide D
mm
12 mm
276 mm
=
300 mm
24
18
63.27160494
196.3446502
OUTCOME
KN/m2
KN/m2
98 * 6 / (2 * 1.8 ^2)
100.823
250 KN/m2
kN/m2 <
675
R = Mu/bdx2
mm
at face of column
at footing edge
( 0.164 -0.088 ) * (1/2) *1800 * 675 ^2 * 2/3
20671875
56.95 kN-m
0.5314536583 MPa
0.00125322
% OF STEEL PROVIDED
0.25
% OF STEEL REQUIRED
>
0.125
1098 mm2
Using
12
=
=
1098 / 113
10
Spacing = 188.888889 mm
Provide
10 Nos OF
675
mm
0.1641 ) /2
Nmm
R = Mu/bdy2
0.5940357393 MPa
0.00140518
648 mm2
Using
<
12
586.802629 mm2
=
=
Spacing =
587 / 113
6
340 mm
Provide
6 Nos
ok
FOOTING CODE
DEPTH OF FOUNDATION =
final result
SIZE OF FOOTING
B=
1800
mm
L=
BOTTOM REINFORCEMENT IN LONGER SIDE
Provide
10 Nos OF
12
WITH SPACING
BOTTOM REINFORCEMENT IN SHORTER SIDE
Provide
6 Nos
WITH SPACING
1.5 m
Column
B =
L
=
Fck =
Fe =
1800
mm
D=
300
L=
bars at uniform spacing in the long direction
180 mm
B=
12 bars at uniform spacing in the long direction
340 mm
STAAD MODEL NODE NO.
300 mm
450 mm
25
500
mm
103
EMO
Footing Summary
L
D
DIA
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
NODE
84
86
87
88
89
90
110
91
92
93
94
95
96
97
98
99
100
101
102
103
2000
2250
2500
2250
2000
2200
2500
2500
2600
2800
2600
2100
2000
1900
2100
2200
2100
1800
2000
1800
2000
2250
2500
2250
2100
2200
2500
2500
2600
2800
2600
2100
2000
1900
2100
2200
2100
1800
2000
1800
350
400
440
400
320
380
450
450
450
500
450
350
350
300
350
350
350
300
275
300
IN L DIRECTION
SPACING
NO.
140
14
230
10
210
12
230
10
330
7
260
9
200
13
200
13
200
13
180
16
200
13
280
8
140
14
180
11
280
8
300
8
280
8
180
10
210
10
180
10
12
16
16
16
16
16
16
16
16
16
16
16
12
12
16
16
16
12
12
12
DIA
IN B DIRECTION
SPACING
NO.
230
9
300
8
260
10
300
8
470
5
350
7
300
9
300
9
250
11
240
12
250
11
330
7
230
9
250
8
400
6
350
7
400
6
340
6
270
8
280
7
12
16
16
16
16
16
16
16
16
16
16
16
12
12
16
16
16
12
12
12
969
498
202
461
741
996
748
386
666
967
980
1080
1333
1083
551
430
315
482
582
477
274
210
205
116
130
144
129
112
133
140
150
147
155
147
129
138
111.6
139
138
136
84
146
140
121
134
148
135
118
147
150
124
120