Beruflich Dokumente
Kultur Dokumente
MRQA
UNLOADING VALVE
(FOR CIRCUITS WITH ACCUMULATOR)
SERIES 42
SUBPLATE MOUNTING
ISO 4401-03 (CETOP 03)
p max 350 bar
Q max 40 l/min
MOUNTING INTERFACE
OPERATING PRINCIPLE
ISO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
B P
MRQA-*/C
PERFORMANCE RATINGS
Maximum operating pressure
bar
350
l/min
40
-20 / +50
-20 / +80
cSt
10 400
MRQA
MRQA*/C
21 400/112 ED
25
kg
3,3
4,2
1/2
MRQA
SERIES 42
1 - IDENTIFICATION CODE
M R Q A -
/ 42 /
Unloading valve
Series No. (the overall and
mounting dimensions remain
unchanged from 40 to 49)
2 - CHARACTERISTIC CURVES
ADJUSTMENT
[bar]
p [%]
100
350
MRQA- 6
90
210
MRQA- 5
80
70
0
MRQA- 3
70
10
20
30
40
Q [l/min]
RESETTING PRESSURES
MRQA*/1
MRQA*/2
P T
60
10
20
30
PRESSURE
CYCLE
CICLO
PRESSIONI
40
Q [l/min]
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
dimensions in mm
21 400/112 ED
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2/2