Sie sind auf Seite 1von 16

Bjeljina

Ulica Srpske Vojske


1,7m tratoar + 6m kolovoz +1,7m tratoar
visina stubova 10m, razmak 35m
Sada: 250W
LED: 119W
Evropska klasifikacija puta ME3
Ulica Filipa Vinjia
1,7m tratoar + 6m kolovoz +1,7m tratoar
visina stubova 10m, razmak 30m
Sada: 250W
LED: 79W
Evropska klasifikacija puta ME4
Ulica 27. mart
1,7m tratoar + 6m kolovoz +1,7m tratoar
visina stubova 8m, razmak 25m
Sada: 250W
LED: 79W
Evropska klasifikacija puta ME3

Partner for Contact:


Order No.:
Company:
Customer No.:

Date: 23.08.2012
Operator:

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Srpske Vojske / Planning data


Ulica Srpske Vojske
1,7m tratoar + 6m kolovoz + 1,7m tratoar
visina stubova 10m, razmak 35m
Sada: 250W
LED: 119W

Street Profile
tratoar

(Width: 1.700 m)

kolovoz

(Width: 6.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

tratoar

(Width: 1.700 m)

Light loss factor: 1.00


Luminaire Arrangements

Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):

LUXTELLA xxx_#1
12518 lm
12500 lm
119.0 W
Single row, top
35.000 m
10.000 m
9.996 m
-1.000 m
0.0
0.000 m

Maximum luminous intensities


at 70:
533 cd/klm
at 80:
116 cd/klm
at 90:
25 cd/klm
Any direction forming the specified angle from the downward vertical, with the luminaire
installed for use.

No luminous intensities above 90.


Arrangement complies with luminous intensity class G2.
Arrangement complies with glare index class D.4.

Page 2

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Srpske Vojske / kolovoz / Results overview

Light loss factor: 1.00

Scale 1:294

Grid: 12 x 6 Points
Accompanying Street Elements: kolovoz.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME3a

(All lighting performance requirements are met.)

Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Lav [cd/m]
1.17
1.00

U0
0.63
0.40

Ul
0.76
0.70

TI [%]
10
15

SR
0.81
0.50

Assigned observer (2 Pieces):


No.

Lav [cd/m]

U0

Ul

TI [%]

(-60.000, 1.500, 1.500)

1.27

0.63

0.82

(-60.000, 4.500, 1.500)

1.17

0.65

0.76

10

Observer

Position [m]

Observer 1

Observer 2

Page 3

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Srpske Vojske / kolovoz / Observer 1 / Isolines (L)

Values in Candela/m, Scale 1 : 294


Grid: 12 x 6 Points
Observer Position: (-60.000 m, 1.500 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME3a:

Lav [cd/m]
1.27

U0
0.63

Ul
0.82

TI [%]
7

1.00

0.40

0.70

15

Fulfilled/Not fulfilled:

Page 4

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Srpske Vojske / kolovoz / Observer 2 / Isolines (L)

Values in Candela/m, Scale 1 : 294


Grid: 12 x 6 Points
Observer Position: (-60.000 m, 4.500 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME3a:

Lav [cd/m]
1.17

U0
0.65

Ul
0.76

TI [%]
10

1.00

0.40

0.70

15

Fulfilled/Not fulfilled:

Page 5

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Srpske Vojske / tratoar / Results overview

Light loss factor: 1.00


Grid: 12 x 3 Points
Accompanying Street Elements: tratoar.
Selected Lighting Class: CE5
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Scale 1:294

(All lighting performance requirements are met.)


Eav [lx]
18.56
7.50

U0
0.61
0.40

Page 6

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Filipa Vinjia / Planning data


Ulica Srpske Vojske
1,7m tratoar + 6m kolovoz + 1,7m tratoar
visina stubova 10m, razmak 35m
Sada: 250W
LED: 79W

Street Profile
tratoar

(Width: 1.700 m)

kolovoz

(Width: 6.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

tratoar

(Width: 1.700 m)

Light loss factor: 1.00


Luminaire Arrangements

Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):

LUXTELLA xxx_#1
8312 lm
8300 lm
79.0 W
Single row, top
30.000 m
10.000 m
9.996 m
-1.000 m
0.0
0.000 m

Maximum luminous intensities


at 70:
533 cd/klm
at 80:
116 cd/klm
at 90:
25 cd/klm
Any direction forming the specified angle from the downward vertical, with the luminaire
installed for use.

No luminous intensities above 90.


Arrangement complies with luminous intensity class G2.
Arrangement complies with glare index class D.4.

Page 7

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Filipa Vinjia / kolovoz / Results overview

Light loss factor: 1.00

Scale 1:258

Grid: 10 x 6 Points
Accompanying Street Elements: kolovoz.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a

(All lighting performance requirements are met.)

Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Lav [cd/m]
0.91
0.75

U0
0.64
0.40

Ul
0.81
0.60

TI [%]
8
15

SR
0.81
0.50

Assigned observer (2 Pieces):


No.

Lav [cd/m]

U0

Ul

TI [%]

(-60.000, 1.500, 1.500)

0.99

0.64

0.89

(-60.000, 4.500, 1.500)

0.91

0.65

0.81

Observer

Position [m]

Observer 1

Observer 2

Page 8

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Filipa Vinjia / kolovoz / Observer 1 / Isolines (L)

Values in Candela/m, Scale 1 : 258


Grid: 10 x 6 Points
Observer Position: (-60.000 m, 1.500 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME4a:

Lav [cd/m]
0.99

U0
0.64

Ul
0.89

TI [%]
6

0.75

0.40

0.60

15

Fulfilled/Not fulfilled:

Page 9

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Filipa Vinjia / kolovoz / Observer 2 / Isolines (L)

Values in Candela/m, Scale 1 : 258


Grid: 10 x 6 Points
Observer Position: (-60.000 m, 4.500 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME4a:

Lav [cd/m]
0.91

U0
0.65

Ul
0.81

TI [%]
8

0.75

0.40

0.60

15

Fulfilled/Not fulfilled:

Page 10

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica Filipa Vinjia / tratoar / Results overview

Light loss factor: 1.00


Grid: 10 x 3 Points
Accompanying Street Elements: tratoar.
Selected Lighting Class: CE5
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Scale 1:258

(All lighting performance requirements are met.)


Eav [lx]
14.38
7.50

U0
0.65
0.40

Page 11

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica 27. mart / Planning data


Ulica Srpske Vojske
1,7m tratoar + 6m kolovoz + 1,7m tratoar
visina stubova 10m, razmak 35m
Sada: 250W
LED: 79W

Street Profile
tratoar

(Width: 1.700 m)

kolovoz

(Width: 6.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

tratoar

(Width: 1.700 m)

Light loss factor: 1.00


Luminaire Arrangements

Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):

LUXTELLA xxx_#1
8312 lm
8300 lm
79.0 W
Single row, top
25.000 m
8.000 m
7.996 m
-1.000 m
0.0
0.000 m

Maximum luminous intensities


at 70:
533 cd/klm
at 80:
116 cd/klm
at 90:
25 cd/klm
Any direction forming the specified angle from the downward vertical, with the luminaire
installed for use.

No luminous intensities above 90.


Arrangement complies with luminous intensity class G2.
Arrangement complies with glare index class D.4.

Page 12

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica 27. mart / kolovoz / Results overview

Light loss factor: 1.00

Scale 1:222

Grid: 10 x 6 Points
Accompanying Street Elements: kolovoz.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME3a

(All lighting performance requirements are met.)

Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Lav [cd/m]
1.23
1.00

U0
0.54
0.40

Ul
0.83
0.70

TI [%]
10
15

SR
0.69
0.50

Assigned observer (2 Pieces):


No.

Lav [cd/m]

U0

Ul

TI [%]

(-60.000, 1.500, 1.500)

1.34

0.54

0.90

(-60.000, 4.500, 1.500)

1.23

0.56

0.83

10

Observer

Position [m]

Observer 1

Observer 2

Page 13

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica 27. mart / kolovoz / Observer 1 / Isolines (L)

Values in Candela/m, Scale 1 : 222


Grid: 10 x 6 Points
Observer Position: (-60.000 m, 1.500 m, 1.500 m)
tarmac: R3, q0: 0.070

Calculated values:
Required values according to class ME3a:

Lav [cd/m]
1.34

U0
0.54

Ul
0.90

TI [%]
6

1.00

0.40

0.70

15

Fulfilled/Not fulfilled:

Page 14

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica 27. mart / kolovoz / Observer 2 / Isolines (L)

Values in Candela/m, Scale 1 : 222


Grid: 10 x 6 Points
Observer Position: (-60.000 m, 4.500 m, 1.500 m)
tarmac: R3, q0: 0.070

Calculated values:
Required values according to class ME3a:

Lav [cd/m]
1.23

U0
0.56

Ul
0.83

TI [%]
10

1.00

0.40

0.70

15

Fulfilled/Not fulfilled:

Page 15

Bjeljina
23.08.2012

Operator
Telephone
Fax
e-Mail

Ulica 27. mart / tratoar / Results overview

Light loss factor: 1.00


Grid: 10 x 3 Points
Accompanying Street Elements: tratoar.
Selected Lighting Class: CE5

Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:

Scale 1:222

(All lighting performance requirements are met.)


Eav [lx]
21.55
7.50

U0
0.64
0.40

Page 16

Das könnte Ihnen auch gefallen