Job Information

Engineer

Checked

Approved

Included in this printout are data for:


Design Group

Design Brief

Design Code

Members

Column Main Reinforcement

Member

Axial

Major

Minor

Design

Unity

Total

As Prov.

(kN)

(kNm)

(kNm)

Axis

Ratio

Bars

(mm2)

L/C

Summary: the group is safe

Column Shear Reinforcement

Value
Member

Position

L/C

Value

Position

Asv Req.

Link

(kN)

(m)

(mm2)

Size

L/C
(kN)

(m)

Summary: the group is safe

Member 1 - Detailed ACI Design Requirements

Section Property: 200 x 400


Storey height

= 5.000 m

Rectangular section:
Cover

Width

= 200 mmDepth

= 400 mm

= 40 mm

Member 1 - Detailed ACI Main Reinforcement

Axial N
Major M,

Minor M,

= 306.50 kN
end 1,

= 20.95 kNm

end 2,

= -18.66 kNm

end 1,

= 1.19 kNm

end 2,

= -0.31 kNm

Minimum Moments from eccentricity M2y, min

= 8.28 kNm

Minimum Moments from eccentricity M2z, min

= 6.44 kNm

Only one of these moments should be considered for design

10.12.3.2

M2y, min set as 0.0

= 0 mm2

Additional longitudinal reinforcement area required for torsion


Strength Reduction factor
Axial Capacity Pn

= 0.90
= 306.50 kN

Axial capacity ratio Pu / Pn

= 1.00

Axial Capacity Axial

OK for axial resistance

Major Axis Capacity Mny

= 96.38 kNm

Major Axis Capacity Ratio Muy / Mny

= 0.43

Major Axis Capacity Major Axis Moment


Minor Axis Capacity Mnz

OK for moment resistance


= 29.98 kNm

Minor Axis Capacity Ratio Muz / Mnz

= 0.21

Minor Axis Capacity Minor Axis Moment

OK for moment resistance

Biaxial Interaction Equation

= [(Muz/Mnz)]a + [(Muy/Mny)]a1.0

Where exponent a

= 1.24

Biaxial Interaction Equation

= [(6.44/29.98)]1.24 + [(41.90/96.38)]1.24

Biaxial Interaction Result 1.0

= 0.50

OK for biaxial resistance

Max distance between bars

= 300 mm

Largest actual space between bars

= 263 mm

Min distance between bars

= 40 mm 3.3.2(c)&7.6.3

Smallest actual space between bars

= 63 mm
OK for spacing

= 800 mm2

Min area of reinforcement

10.9.1

Max area of reinforcement (even at laps)

= 6400 mm2

Actual area of main reinforcement (4#19)

= 1146 mm2

area by which steel can increase at laps

= 5254 mm2
= 1136 mm2

Starter bar area


OK

Member 1 - Detailed ACI Shear Reinforcement

Maximum spacing of ties

= 200 mm7.10.5.2

Actual spacing of ties, s

= 200 mm

Major axis:
Design torsion moment, Tu
Threshold Torsion

= 0.04 kNm
= 0.083fc' [(Acp2/pcp)] [1 + (Nu/0.33Agfc')]0.5

Tu < Threshold Torsion torsion effects do not need to be considered

Shear force, Vu

= 0.30 kN

= 3.24 kNm

11.6.1 (c)
11.6.1

Vc = 0.17 [1 + (Nu/14 Ag)] fc' bw d

= 67.66 kN

Vu Vc

11.1.1

only nominal ties required

11.2&11.3

= 142 mm2

Area of ties provided (2#10), Av

Minor axis:
Design torsion moment, Tu

= 0.04 kNm
= 0.083fc' [(Acp2/pcp)] [1 + (Nu/0.33Agfc')]0.5

Threshold Torsion

= 3.24 kNm

Tu < Threshold Torsion torsion effects do not need to be considered

Shear force, Vu

= 55.94 kN

Vu Vc

11.1.1

only nominal ties required

= 142 mm2

Area of ties provided (2#10), Av

Minimum size of link bars

= #22

Actual size of link bars

= #10
OK

Member 2 - Detailed ACI Design Requirements

Section Property: 200 x 400


Storey height

= 3.000 m

Rectangular section:
Cover

Width

= 200 mmDepth

= 40 mm

Member 2 - Detailed ACI Main Reinforcement

Axial N
Major M,

= 69.73 kN
end 1,

11.6.1

= 7.92 kN

Vc = 0.17 [1 + (Nu/14 Ag)] fc' bw d

= 3.70 kNm

= 400 mm

7.10.5.1

11.6.1 (c)

11.2&11.3

Minor M,

end 2,

= -1.11 kNm

end 1,

= -4.31 kNm

end 2,

= 2.57 kNm

Minimum Moments from eccentricity M2y, min

= 1.88 kNm

Minimum Moments from eccentricity M2z, min

= 1.46 kNm

Only one of these moments should be considered for design

10.12.3.2

M2z, min set as 0.0

= 0 mm2

Additional longitudinal reinforcement area required for torsion


Strength Reduction factor

= 0.90

Axial Capacity Pn

= 69.73 kN

Axial capacity ratio Pu / Pn

= 1.00

Axial Capacity Axial

OK for axial resistance

Major Axis Capacity Mny

= 66.30 kNm

Major Axis Capacity Ratio Muy / Mny

= 0.11

Major Axis Capacity Major Axis Moment

OK for moment resistance

Minor Axis Capacity Mnz

= 28.19 kNm

Minor Axis Capacity Ratio Muz / Mnz

= 0.31

Minor Axis Capacity Minor Axis Moment

OK for moment resistance

Biaxial Interaction Equation

= [(Muz/Mnz)]a + [(Muy/Mny)]a1.0

Where exponent a

= 1.24

Biaxial Interaction Equation

= [(8.62/28.19)]1.24 + [(7.41/66.30)]1.24

Biaxial Interaction Result 1.0

= 0.30

OK for biaxial resistance

Max distance between bars

= 300 mm

Largest actual space between bars

= 263 mm

Min distance between bars

= 40 mm 3.3.2(c)&7.6.3

Smallest actual space between bars

= 63 mm
OK for spacing

= 800 mm2

Min area of reinforcement

10.9.1

Max area of reinforcement (even at laps)

= 6400 mm2

Actual area of main reinforcement (4#19)

= 1146 mm2

area by which steel can increase at laps

= 5254 mm2
= 1136 mm2

Starter bar area


OK

Member 2 - Detailed ACI Shear Reinforcement

Maximum spacing of ties

= 200 mm7.10.5.2

Actual spacing of ties, s

= 200 mm

Major axis:
Design torsion moment, Tu

= 0.05 kNm
= 0.083fc' [(Acp2/pcp)] [1 + (Nu/0.33Agfc')]0.5

Threshold Torsion

= 2.16 kNm

Tu < Threshold Torsion torsion effects do not need to be considered

Shear force, Vu

11.6.1 (c)
11.6.1

= 2.29 kN

Vc = 0.17 [1 + (Nu/14 Ag)] fc' bw d

= 56.43 kN

Vu Vc

11.1.1

only nominal ties required

11.2&11.3

= 142 mm2

Area of ties provided (2#10), Av

Minor axis:
Design torsion moment, Tu
Threshold Torsion

= 0.05 kNm
= 0.083fc' [(Acp2/pcp)] [1 + (Nu/0.33Agfc')]0.5

= 2.16 kNm

Tu < Threshold Torsion torsion effects do not need to be considered

Shear force, Vu

11.6.1

= 1.61 kN

Vc = 0.17 [1 + (Nu/14 Ag)] fc' bw d

= 46.66 kN

Vu Vc

11.1.1

only nominal ties required

11.6.1 (c)

11.2&11.3

= 142 mm2

Area of ties provided (2#10), Av

Minimum size of link bars

= #22

Actual size of link bars

= #10
OK

7.10.5.1