Sie sind auf Seite 1von 2

AF-300 C11

A D J U S TA B L E
FREQUENCY DRIVE

GE Fuji Drives USA


Space: A precious commodity in
todays high-tech machinery and

AF-300 C11

applications. The AF-300 C11

Adjustable Frequency Drive

ac drives are fully equipped with

The AF-300 C11 drive is designed for use in small machines such as fans and
conveyors, as well as other machines in which motor speeds can vary. The AF-300 C11
series is available in thirteen models, from 1/8 to 5 hp, allowing you to select the model
that best suits your application. The AF-300 C11 only requires power and motor
connections to the built-in
terminal block for use.
Easy-to-follow programming
and output frequency can be
set and adjusted using the
keypad panel. Quick response
time delivers reliable operation against load fluctuation.
Self-diagnostics provide
shut-off protection and fault
failure messages. Each unit
also has a standard frequency setting POT mounted on
the face of the drive for quick
adjustments and standard
built-in PID loop.

The AF-300E$ is the perfect drive


for GE Motors and GE Fanuc PLCs,
as well as other manufacturers
products.

Selectable functions
include operating
method/frequency
setting, base and
top frequency, maximum output
frequency, torque boost, DC
braking, accel/decel, multifrequency settings, and motor
sound adjustments.

over 30 configurable motor control


functions in a light-weight, compact housing. AF-300 C11 drives
can be used even in areas where
there are noise-level restrictions.
They are also UL and CE rated.

Your Standard Drive Source


Environmental
Conditions

Enclosure
Installation Location

IP20
Do not install in locations where product could be exposed to dust, corrosive gas, inflammable
gas, oil mist, vapor, water drops, or direct sunlight. There must be no salt in the atmosphere.
Condensation must not be caused by sudden changes in temperature. For use at altitudes of
3300 ft. (1000m) or less without derating.
-10C to +50C (+14F to +122F)
5 to 95% RH (non-condensing)
3mm:
2 to less than 9 Hz
9 to less than 20 Hz
9.8m/s2:
20 to less than 55 Hz
2 m/s2:
55 to less than 200 Hz
1 m/s2:
-25C to +65C (-4F to +149F)

Ambient Temperature
Ambient Humidity
Vibration

Storage Temperature

Input Frequency
Output Frequency

Power System

220-240 VAC, single-phase, 50-60 Hz +10% to -15% V, +5% to -5% Hz


200-230 VAC, three-phase, 50-60 Hz +10% to -15% V, +5% to -5% Hz

Setting

Maximum frequency:
50 to 120 Hz (in 1 Hz steps)
Base frequency:
25 to 120 Hz (in 1 Hz steps)
Starting frequency:
1 to 6 Hz (in 1 Hz steps)
Digital setting: 0.01% of maximum frequency (from -10C to +50C)
Analog setting: 1.0% of maximum frequency (at 25C 10C)
Digital setting: 0.1 Hz (99.9 Hz or less), 1 Hz (100 Hz or more)
Analog setting: 1/256 of maximum frequency (ex. 0.23 Hz for 60 Hz, 0.47 Hz for 120 Hz)

Accuracy (Stability)
Setting Resolution

Control

Control Method
Operation Method

Frequency Setting

Indication
Acceleration/Deceleration Time
Voltage/Frequency (V/F)
Characteristics
PID Control
Restart After Momentary
Power Failure
Frequency Limiter
Bias Frequency
Frequency Jump Control
Torque Boost
Starting Torque

Protection

Overload
Instantaneous Overcurrent

Sinusoidal PWM control (with simplified current vibration suppression)


Keypad operation: RUN or STOP key
Input signal: Forward/Reverse command, Coast-to-Stop command, Trip command (external
alarm and alarm reset)
Keypad operation: INC (UP) or DEC (DOWN) keys
Built-in or external potentiometer of 1 to 5K ohm
Analog input: 0 to 5 VDC, 0 to 10 VDC (Resistance = 22K ohm), 4 to 20 mA DC
Multistep frequency: Up to 4 different frequencies can be selected using X input terminals
Modbus RTU option
Running: Digital indication of output frequency or output current (3 digit LED)
Tripped: Cause of trip by code (3 digit LED)
0.1 to 60.0s (independently adjustable acceleration and deceleration)
Adjustable maximum frequency and base frequency
PID control function is provided as a standard feature
Drive restarts without causing the motor to stop if the automatic restart is specified
for the drive
High and low limits can be set for the output frequency between 0 to 100% Hz
The bias frequency can be set from -100 to +100 Hz
Jump frequency (3 points) and jump hysteresis width (1 point) can be preset
32 step selectable
150% or more at 6 Hz
Detects overload to stop drive
Detect overcurrent due to overload on the drive output side to protect drive. Protects drive in
case of ground fault (when starting) and short circuit of output circuit.
Detects DC link circuit overvoltage to stop drive
Detects abnormal temperature of cooling fin to stop drive
Electronic thermal overload detector
Outputs a relay contact signal when any protective function is activated
(SPDT contact, 250 VAC, 0.3A, cos = 0.3)

Overvoltage
Overheating
Motor Protection
Alarm Output

Options

AF-300 C11 Specifications

Standard
Communications

DIN-Rail mounting kit and EMI filter


Modbus RTU

BAUART
GEPRFT
TV
Rheinland
Product Safety

GEA-S1021
000502
FERGADV

TYPE
APPROVED

AF-300 C11 is a trademark of General Electric Company

GE Fuji Drives USA


GE Fuji Drives USA, Inc.
1501 Roanoke Blvd., Suite 435
Salem, VA 24153
1-800-543-6196
www.GEindustrial.com

Das könnte Ihnen auch gefallen