Sie sind auf Seite 1von 12

CentriPro

4" Motors and Controls

Quick Disconnect Control Box Features


Voltage Relays for installer convenience
208 volt relay available for low voltage applications
NEMA 3R enclosure for indoor or outdoor mounting
Quick disconnect cover design will retrofit with F.E. Q-D control boxes
agency listings:

115 and 230 volt models


Start Capacitors
Multiple knockouts
Two ground lugs

Ul

CentriPro Order Numbers


Control Box

HP
KW
Volts
Order Number



CB05411
CB05412
CB07412
CB10412

.5
.5
.75
1

.37
.37
.55
.75

115
230
230
230

Replaces
old #

Replaces
FE #

Enclosure Dimensions
W x D x H (in)

Shipping
Weight (lbs)

00043
00044
00054
00064

280 104 49
280 105 49
280 107 49
280 108 49

4.8 x 2.9 x 8.4


4.8 x 2.9 x 8.4
4.8 x 2.9 x 8.4
4.8 x 2.9 x 8.4

4
4
4
4

Note: 208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.

CSCR (Capacitor Start-Capacitor Run) Control Box Features


Voltage Relay for installer convenience
230 volt standard models 208 volt relay, order no. 9K479 is available for low voltage
applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quiet operation
Type 3R enclosure for indoor or outdoor mounting
Accepts up to #2 AWG wire
Multiple knockouts and two ground terminals
Higher HP models require heavy duty pressure switches
See Magnetic Contactor version to use standard pressure switches
Ul Tested to UL and CSA
agency
Manual reset overloads on 1 5 HP models
standards by UL.
C
US
listings:

Control Box

May Replace
May Replace
May Replace

Order
HP
KW
Volts

GP #
RJ #
FE #
Number


50F311CB
2824055015
CB05412CR
0.5
.37
230
NA

S50N1CB, A50N1CB



75F311CB
2824075015
CB07412CR
.75
.55
230
NA


S75N1CB, A75N1CB



S100F311CB
2824085015
CB10412CR
1
.75
230
NA

S100N1CB, A100N1CB



150F311CB
CB15412CR
1.5
1.1
230
00074
282 3008 110

S150N1CB, A150N1CB


200F311CB
CB20412CR
2
1.5
230
00084
282 3018 110

S200N1CB, AS200T1CB


300F311CB
CB30412CR
3
2.2
230
00094
282 3028 110

S300N1CB


500F311CB
CB50412CR
5
3.7
230
00104
282 1138 110

S500N1CB
4

Enclosure
Dimensions
W x D x H (in)

Shipping
Weight (lbs)

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

IT T

Residential Water

CentriPro
Quick Disconnect Control Boxes
For 4", 1, 3-Wire Submersible Motors
Features
Voltage Relays for installer convenience
115 and 230 volt models
208 volt relay, 9K461, available for low
voltage applications
Start Capacitors
NEMA 3R enclosure for indoor or outdoor mounting
Quick disconnect cover design will retrofit with F.E. Q-D control boxes
Multiple knockouts
Two grounding lugs
agency listings

UL

Listed to UL778 Standard by Underwriters


Laboratories Inc. File No. E83318

CentriPro

CentriPro is a brand of ITT Corporation.


www.centripro.com

Engineered for life

CSA certified to C22.2, No. 108 Standard


by Canadian Standards Association,
File No. LR38549

IT T

CENTRIPRO

Residential Water

centripro order numbers


Control Box
Order
HP
KW
Volts
Number
CB05411
.5
.37
115
CB05412
.5
.37
230
CB07412
.75
.55
230
CB10412
1
.75
230

Replaces Replaces
old
FE #
#
00043 280 104 49
00044 280 105 49
00054 280 107 49
00064 280 108 49

Standard
Standard
Circuit
Fuse
Breaker
30 A
35 A
15 A
20 A
20 A
25 A
25 A
30 A

Dual Element
Time Delay
Fuse
20 A
10 A
15 A
20 A

Enclosure
Shipping
Dimensions Wt. (lbs)
W x D x H (in)
4.8 x 2.9 x 8.4
4
4.8 x 2.9 x 8.4
4
4.8 x 2.9 x 8.4
4
4.8 x 2.9 x 8.4
4

Note: 208 Volt starting relay, 9K461, is available for 200-208 volt power supplies.

K repair parts for quick disconnect style control boxes*


CentriPro
Old
Capacitor
Start

Start
Capacitor
Capacitor

Order
Order
HP
Volts
Order
Capacitor
Relay
Voltage
Quantity
Number
Number
Number
Mfd
Order No.


CB05411
00043 (GP)
.5
115
9K450
250 - 300
125
1
9K457

CB05412
00044 (GP)
.5
230
9K448
59 - 71
220
1
CB07412
00054 (GP)
.75
230
9K449
86 - 103
220
1
9K462
CB10412
00064 (GP)
1
230
9K447
105 - 126
220
1
Special 208 V Relay for .5 - 1 HP operating on 200 or 208 volt power supplies Order No. 9K461.

Supplier
Number
RVA7AA (6L)
(or KL)
RVA2AL (6L)
(or KL)

* Repair parts above will work in new voltage relay control boxes as well as in control boxes shown in "Replaces
Column" above.

IT T

CENTRIPRO

Residential Water

Installing a PumpSaver Insider


1. Remove the cover from the front of the 3-wire CentriPro control box.
2. Remove the yellow wire from the terminal strip at L2.
3. Remove the black wire from L1 to the capacitor.
4. Press the PumpSaver onto the L1 and L2 terminals.
5. Reconnect the yellow wire to L2 on the PumpSaver.
6. Connect the blue wire attached to the PumpSaver to the
dual-lug terminal (with the black wire) of the capacitor.

ORANGE
BLUE

MODEL 111/231
INSIDER

VOLTAGE
RELAY

BLK
2

5
YEL
RED

B(MAIN)

Y(COMM)

YEL

R(START)

L2

L1

IT T

Residential Water

wiring diagram

GND

ORANGE

START

RELAY

CAPACITOR

GREEN

GND
1

RED

GREEN
BLACK
YEL.

BLACK
YELLOW
MAIN (B)

COMM (Y)

START (R)

(MOTOR LEADS)

CentriPro

CentriPro and the ITT Engineered Blocks Symbol are


registered trademarks and tradenames of ITT Corporation.
PumpSaver is a registered trademark of SymCom, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

BCQD April, 2008


2008 ITT Corporation

Engineered for life

L2

L1
(LINE LEADS)

CentriPro

4" Motors and Controls

Quick Disconnect Control Box Features


Voltage Relays for installer convenience
208 volt relay available for low voltage applications
NEMA 3R enclosure for indoor or outdoor mounting
Quick disconnect cover design will retrofit with F.E. Q-D control boxes
agency listings:

115 and 230 volt models


Start Capacitors
Multiple knockouts
Two ground lugs

Ul

CentriPro Order Numbers


Control Box

HP
KW
Volts
Order Number



CB05411
CB05412
CB07412
CB10412

.5
.5
.75
1

.37
.37
.55
.75

115
230
230
230

Replaces
old #

Replaces
FE #

Enclosure Dimensions
W x D x H (in)

Shipping
Weight (lbs)

00043
00044
00054
00064

280 104 49
280 105 49
280 107 49
280 108 49

4.8 x 2.9 x 8.4


4.8 x 2.9 x 8.4
4.8 x 2.9 x 8.4
4.8 x 2.9 x 8.4

4
4
4
4

Note: 208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.

CSCR (Capacitor Start-Capacitor Run) Control Box Features


Voltage Relay for installer convenience
230 volt standard models 208 volt relay, order no. 9K479 is available for low voltage
applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quiet operation
Type 3R enclosure for indoor or outdoor mounting
Accepts up to #2 AWG wire
Multiple knockouts and two ground terminals
Higher HP models require heavy duty pressure switches
See Magnetic Contactor version to use standard pressure switches
Ul Tested to UL and CSA
agency
Manual reset overloads on 1 5 HP models
standards by UL.
C
US
listings:

Control Box

May Replace
May Replace
May Replace

Order
HP
KW
Volts

GP #
RJ #
FE #
Number


50F311CB
2824055015
CB05412CR
0.5
.37
230
NA

S50N1CB, A50N1CB



75F311CB
2824075015
CB07412CR
.75
.55
230
NA


S75N1CB, A75N1CB



S100F311CB
2824085015
CB10412CR
1
.75
230
NA

S100N1CB, A100N1CB



150F311CB
CB15412CR
1.5
1.1
230
00074
282 3008 110

S150N1CB, A150N1CB


200F311CB
CB20412CR
2
1.5
230
00084
282 3018 110

S200N1CB, AS200T1CB


300F311CB
CB30412CR
3
2.2
230
00094
282 3028 110

S300N1CB


500F311CB
CB50412CR
5
3.7
230
00104
282 1138 110

S500N1CB
4

Enclosure
Dimensions
W x D x H (in)

Shipping
Weight (lbs)

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

BCCR

IT T

Residential Water Systems

CentriPro

CSCR 1 Control Boxes


Capacitor Start - Capacitor Run for
3-wire, 5 HP Submersible Motors

Features
Voltage Relay for installer convenience
230 volt models 208 volt relay, 9K479,
available for low voltage applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quiet
operation
Type 3R enclosure for indoor or outdoor
mounting
Accepts up to #2 AWG wire
Multiple knockouts and two ground
terminals
Higher HP models require heavy duty pressure switches See Magnetic Contactor
version to use standard pressure switches
Manual reset overloads on 1 5 HP
models

CentriPro

Agency ListingS
C

CentriPro is a brand of ITT Corporation.


www.centripro.com

Engineered for life

UL

Tested to UL and CSA standards by UL.


US

IT T

Residential Water Systems

Control Box


May
Standard
Dual Element
May Replace
May Replace
Order
Hp KW Volts Replace

Circuit Standard

Time Delay
RJ
#
FE
#
Fuse
Number



GP #


Breaker

Fuse


50F311CB
CB05412CR 0.5 .37 230

15
20
10

S50N1CB, A50N1CB 2824055015


75F311CB
CB07412CR .75 .55 230

20
25
15

S75N1CB, A75N1CB 2824075015


S100F311CB
CB10412CR 1 .75 230

25
30
20

S100N1CB, A100N1CB 2824085015


150F311CB
CB15412CR 1.5 1.1 230 00074 S150N1CB, A150N1CB 282 3008 110
30
35
20



200F311CB
CB20412CR 2 1.5 230 00084 S200N1CB, AS200T1CB 282 3018 110
25
30
20



300F311CB
CB30412CR 3 2.2 230 00094
282 3028 110
40
45
30

S300N1CB


500F311CB
CB50412CR 5 3.7 230 00104
282 1138 110
60
80
45

S500N1CB

Enclosure
Dimensions Shipping
W x D x H (in) Wt. (lbs)
8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

8.1 x 5.9 x 9.3

K repair parts
Control Box

Old Control Capacitor
Order
HP Volts Box Order Repair Part
Number


Number
Number


9K465
CB05412CR .5
230


9K466


9K448
CB07412CR .75 230


9K467


9K449
CB10412CR 1
230


9K467


9K447
CB15412CR 1.5 230
00074

9K452


9K447
CB20412CR 2
230
00084

9K451


9K453
CB30412CR 3
230
00094

9K454


9K455
CB50412CR 5
230
00104

9K456

Capacitor
Mfd.

43-53
15
59-71
23
86-103
23
105-126
10
105-126
20
208-250
45
270-324
40

Capacitor
Type

Start
Run
Start
Run
Start
Run
Start
Run
Start
Run
Start
Run
Start
Run

CentriPro

CentriPro is a registered trademark of ITT Corporation. ITT,


the Engineered Blocks Symbol and Engineered for Life are
Registered trademarks of ITT Manufacturing Enterprises, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

BCCR January, 2010


Copyright (c) 2010 ITT Corporation

Engineered for life

Overload
Capacitor
Capacitor
Order
Voltage
Quantity


Number
250
1 NA
370
250
1 N/A
370
250
1 N/A
370
250
1
9K471
370
250
1
9K481
370
250
1
9K482
370
330
1
9K483
370
2

Start Relay
Order
Number
9K458
9K458
9K458
9K458
9K458

9K459

New 1 HP CSCR control box is now in a larger enclosure, it is not


in a quick disconnect style enclosure.
Overloads for 2, 3 and 5 HP CSCR boxes are sold prewired and
soldered as an assembly. No field soldering or wiring required.
If supply voltage is between 200 V 210 V a 208 V start relay,
order no. 9K479, is required.

Magnetic Contactor 1 Control Boxes


For 3-wire, 1 5 HP Submersible Motors

Features
Built-in Magnetic Contactors allow the use of
standard pressure switches, prolong switch
life and eliminate the need to source and
install separate contactors, saving installation
time and reducing total system component
costs.
Voltage Relay for installer convenience
230 volt standard models 208 volt relay,
order no. 9K479 is available for low voltage
applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quiet
operation
Type 3R enclosure for indoor or outdoor
mounting

1 3 HP

Accepts up to #2 AWG wire


Multiple knockouts and two ground
terminals
Manual reset overloads on 1 5 HP
models
Agency ListingS:
C

Ul

Tested to UL and CSA standards by UL.


US

BCMC

IT T

Residential Water Systems

CentriPro

Magnetic Contactor 1 Control Boxes


For 3-wire, 1 5 HP Submersible Motors

Features
Built-in Magnetic Contactors allow the use
of standard pressure switches, prolong
switch life and eliminate the need to source
and install separate contactors, saving
installation time and reducing total system
component costs.
Voltage Relay for installer convenience
230 volt standard models 208 volt relay,
9K479 available for low voltage applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quiet
operation
Type 3R enclosure for indoor or outdoor
mounting

1 3 HP
5 HP is in larger enclosure

Accepts up to #2 AWG wire


Multiple knockouts and two ground
terminals

CentriPro

Manual reset overloads on 1 5 HP


models

CentriPro is a brand of ITT Corporation.


www.centripro.com

Engineered for life

Agency ListingS
C

UL

Tested to UL and CSA standards by UL.


US

IT T

Residential Water Systems

Magnetic Contactor (MC) Control Boxes for 3 Wire, 1,


4" CentriPro Motors and 4" (6", 5 HP) Franklin Electric Motors


Control Box


Order Number




Replaces
HP KW Volts
GP #




Replaces

FE #

CB15412MC

1.5 1.1 230 No Equal No Equal No Equal

CB20412MC

2 1.5 230

00084MC No Equal

CB30412MC

3 2.2 230

00094MC

S300N1CBC

CB50412MC

5 3.7 230

00104MC

S500N1CBC

Replaces
RJ #

Standard
Dual Element Enclosure
Standard
Shipping
Circuit

Time Delay Dimensions
Fuse
Wt. (lbs)
Breaker

Fuse
W x D x H (in)
30

35

20

2823018310

25

30

20

2823028310

40

45

30

2821139310

60

80

45

8.1 x 5.9 x 9.3


11 x 6.7 x 12.5

8
15

"K" Repair Parts For Magnetic Contactor "MC" Control Boxes







Capacitor
Control Box HP KW Volts Repair Part Capacitor
Order
Number
Type





Number



9K447
Start
CB15412MC 1.5 1.1

9K452
Run


9K447
Start
CB20412MC 2 1.5


9K451
Run
230


9K453
Start
CB30412MC 3 2.2

9K454
Run


9K455
Start
CB50412MC 5 3.7

9K456
Run

Capacitor
Mfd.

105-126
10
105-126
20
208-250
45
270-324
40

Contactor
Order
Number
250
370
250


1
9K485
370
250
370
330
1

9K486
370
2

Capacitor
Voltage


Capacitor
Quantity

Repair parts above are compatible with and replace parts in old Goulds Pumps or Franklin Electric control boxes.
If supply voltage is between 200 V 210 V a 208 V start relay, order no. 9K479, is required.

CentriPro

CentriPro is a registered trademark of ITT Corporation. ITT,


the Engineered Blocks Symbol and Engineered for Life are
Registered trademarks of ITT Manufacturing Enterprises, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

BCMC January, 2010


Copyright (c) 2010 ITT Corporation

Engineered for life

Overload
Order
Number

Start Relay
Order
Number

9K493
9K480 (S)
9K472 (M)
9K473 (S)
9K474 (M)
9K475 (S)
9K476 (M)

9K458

9K459

BALANCED FLOW

BF20, BF30 and BF50


Constant Pressure Controllers for -2, 3 and 5 HP Submersible Pumps
Features
Enclosure Rating: NEMA 3R, IP22 rainproof,
indoor/outdoor enclosure. Allows mounting
the controller outdoors.
Current Limit Selector Switch: Rotary switch
to set current limit to match motor Service
Factor Amps (SFA).
The controller may be used on smaller
pump/motor combinations as long as the
motor SFA is within the current limit range
of the controller.
Communications Port: RS-232 serial port
to facilitate software updates and future
expansion.
Three sizes available for - 5 HP pumps.
Constant Pressure: The system provides
consistent pressure even as system flow
requirements vary.
Controller acts as a pump protection device
and troubleshooting device.
Flashing LED lights indicate system faults by
number of flashes.
Controller will operate between 190 and
260 volts.
Includes a pressure sensor and sensor cable.
Integrated output motor filter protects
the motor from voltage spikes and limits
electrical interference with devices such as
portable telephones, radios, televisions and
garage door openers.
Cooling fan: Allows operation in ambient
temperatures up to 122F.

Das könnte Ihnen auch gefallen