Sie sind auf Seite 1von 14

heat exchangers

asa
More than 30 years experience in heat transfer equipment made us
a global leader in advanced technologies. This ensures you competitive
pricing, consistent product performance and reliability.
Our production locations are divided between the headquarters
of asa Hydraulik GmbH in Vienna (Austria) and asa of America
in New Jersey (USA).
The modular design and patented solutions of our asa oil coolers offer
many advantages for customizing the oil cooler to your application.
Let us put our knowledge in mobile and industrial applications
to work for you.

asa Hydraulik GmbH in Vienna, Austria (EU)

asa of America in Branchburg, New Jersey (USA)

1989

the first
Production of
Europe.
oler series in
co
oil
d
ar
stand
rough
th
in oil cooling
Intensification
s
rie
se
r
change
plate heat ex

1993
1986

angers

asa heat exch

rubber
Production of
s and
compensator
es
butterfly flang

,
ters in Vienna
New headquar
in
.
Inc
lic
asa Hydrau
foundation of
A
California / US

1991

USA

1980 Europe

GmbH,
asa Hydraulik
Foundation of
lic cooling
au
dr
hy
of
d
build up perio

port sales
More active ex
offices in
by new sales
es
several countri

Progress in cooling stands for developments, advances and innovations


already at work through our customers various mobile and stationary
applications worldwide. According to the standard cooler range, we offer
different options of material and function to adapt the cooler.
These options benefit not only the application itself, but also raise our
customers competitiveness. Our options are your benefits!

progress in

cooling

asa is working at all locations following worldwide quality standards,


confirmed by successful certification of quality management ISO 9001
and client audits. This catalogue provides a technical overview of our
products. Please contact us, if more detailed information is required.

2003
new
Integration of
esses

g proc
manufacturin

2002

1995

r series
new asa coole
Launch of the
ector
nn
Co
al
rs
ive
with asa Un

of a new oil
Presentation
(with 26 bar
s
cooler serie
re)
su
es
pr
ing
work

2006
new
Building of a
pe
ro
Eu
in
re
logistics cent

2005
1998
of the US
Centralization
ey / USA
rs
Je
w
Ne
to
production

uction
of the US prod
Modernisation
, USA
ey
rs
Je
w
plant in Ne

produced to

perform
Our product range gives maximum quality, flexibility and
standardization. We can easily change fittings, mounting parts
and fan drives to fit your application.

Mounting
If desired, our coolers can be delivered with mounting arrangements and protection
housings, which serve for flexible and economic mounting in many assembly situations.
The mechanical stress in mobile applications can be reduced by rubber shock absorbers between the protection housing and the cooler.

Bypass
This symbol indicates the possibility of an integrated bypass on the cooler.
Integrating a bypass system in an asa radiator, is to avoid overstressing the cooler
at cold start conditions (when the oil is extremely viscous). This mode of construction
also reduces high oil flows through the radiator that can for example occur
when hydraulic cylinders are used.

Electric
The temperature control consists of a temperature sensor and a control unit which
controls the fan speed according to the actual oil temperature. This lowers the noise
level of the cooler and increases the durability of the fan motor, due to the fact that
it is not running on maximum speed all the time.
Various thermostats for all coolers types are available.

Connectors
This is our patented asa Universal Connector system (AUC) that offers many possibilities
regarding dimensions and directions of the connection tubes. The flow optimized design
reduces the total pressure drop. The omission of screwed joints reduces the number
of sealing surfaces.

customized 4 you

with 4 options

performance defined

results delivered
Follow the 4 easy steps to compare our products or select the right cooler and get smart
about cooling at our website.

www.asahydraulik.com

Cooler
The simplest way for exact cooler selection is
to choose your type of drive, click on an application
button or our calculation program will lead you to
the cooler information directly. For all other fluids
click the radiator button.

Performance
After selecting a size of the cooler, you can
choose from different types of engines:
12V, 24V, high performance versions,
single phase motors, 3 phase motors, etc,
to get the coolers data sheet.

Options
At the data sheet of a specific cooler, the options are
shown at the bottom right. Check out the options and
accessories available, by clicking the symbols.

Data & Contact


The part numbers of the coolers and the
possible options are given on the data sheets.
Please contact us for any other information or send
your enquiry to support@asahydraulik.com

Oil/Air Cooler ASA 0115


12V, 24V DC

Technical Data
order number

power

description

current

protection

revolution

air flow

noise level

[rpm]

[SCFM]

[dB(A)]

weight

[HP]

[A]

ASA0115AD01

ASA 0115 12V DC

0.34

19.4

IP 68

2850

1090

79

27.1

ASA0115AD02

ASA 0115 24V DC

0.34

9.7

IP 68

2850

1090

79

27.1

[lbs]

radiator material aluminium, 370 psi working pressure (static)

pressure drop at 150 SSU

specific cooling performance

p[PSI]
20

Pspec[HP/F]
[BTU/minF]
9

18

16

14

12

10

2
0
0

10

15

20

25

30

35

40

45

50

Qp[gpm]

Accessories and options on that cooler

0
0

10

15

20

25

30

35

40

45

Qp[gpm]
50

quality through

standardization
Using our standard range means competitive pricing, high quality
through standardization and best availability.

System/Bypass
The shown symbol stands for the possibility of an integrated bypass in the cooler.
Principle: Integrating a bypass system in an asa radiator is to avoid overstressing the cooler at cold
start conditions (when the oil is extremely viscous). This mode of construction also reduces high oil
flows through the radiator that can for example occur when hydraulic cylinders are used.

ASA 0567

ASA 0367

ASA 0257

ASA 0177

ASA 0256

ASA 0929

ASA 0927

ASA 0176

ASA 0115

TT 07

TT 06

TT 04

Bypass

TT 02

available

Cooler Type
TT 01

Bypass

ASA Universal Connector


This sign shows our patented ASA Universal Connector system (AUC)
that offers you many possibilities regarding dimensions and directions
of the connection tubes. The flow optimized design reduces the
total pressure drop. The omission of screwed joints reduces
the number of sealing surfaces.
The ASA Universal Connector is available with tube fittings 24
(progressive ring fittings DIN 2353), with 37 flare tube fittings
(ISO 8434-2), with BSP- and UNF female threads and
with SAE 4-bolt flanges (SAE J518 / code 61).

TT 04

TT 06

TT 07

ASA 0176

ASA 0177

ASA 0256

ASA 0257

ASA 0367

ASA 0567

ASA 0927

ASA 0929

ILLZASA2528L

Connector ASA NG 25 - 28L

ILLZASA2542L1

Connector ASA NG 25 - 42L

ILLZASA3225L

Connector ASA NG 32 - 35L

ILLZASA4042L

Connector ASA NG 40 - 42L

ILLZASA3228L

Connector ASA NG 32 - 28L

ILLZASA3225S

Connector ASA NG 32 - 25S

standard configuration

with adapter plate

optional

on request

ASA 0115

TT 02

Cooler Type
TT 01

ASA Universal Connector

Connectors with tube fitting 24 (progressive ring fittings - DIN 2353)

Connectors with 37 flare tube fittings (ISO 8434-2)


ILLZASA25J16

Connector ASA NG 25 - JIC 1 5/16

ILLZASA32J16

Connector ASA NG 32 - JIC 1 5/16

ILLZASA32J20

Connector ASA NG 32 - JIC 1 5/8 (small o-ring)

ILLZASA32J201

Connector ASA NG 32 - JIC 1 5/8 (large o-ring)

ILLZASA40J24

Connector ASA NG 40 - JIC 1 7/8

Connectors with female thread BSP


ILLZASA25G25

Connector ASA NG 25 - G1

ILLZASA25U16

Connector ASA NG 25 - 1 5/16 UNF

ILLZASA32G32

Connector ASA NG 32 - G1 1/4

ILLZASA32U20

Connector ASA NG 32 - 1 5/8 UNF

Connectors with SAE 4-bolt flange (SAE J518 / code 61)


ILLZASA40S50

Connector ASA NG 40 - SAE 2

Mounting
This symbol labels coolers with different mounting systems to choose.
If desired, our coolers can be delivered with mounting arrangements and protection
housings, which serve for flexible and economic mounting in many assembly
situations. The mechanical stress in mobile applications can be reduced by rubber
shock absorbers between the protection housing and the cooler.

mounting feet

mounting frame

protection casing

ASA 0929

ASA 0927

ASA 0567

ASA 0367

mounting feet

ASA 0257

ASA 0257

ASA 0256

TT 06

ASA 0177

TT 04

protection casing

ASA 0176

TT 02

mounting frame

ASA 0115

TT 01

optional

Cooler Type
TT 07

asa Mounting

Electric
Coolers that are labeled with the shown symbol are available
with various electronic controls.

Temperature Control
The temperature control consists of a temperature sensor and a control unit that
controls the fan speed according the actual oil temperature. This lowers the noise
level of the cooler and increases the durability of the fan motor, because it is not
running on maximum speed all the time.

Thermostat
Also available are various thermostats for all coolers types.

Temperature Switch 50C/ IP 65 (1/2 BSPP thread)


Temperature Switch 60C/ IP 65 (1/2 BSPP thread)

ASA 0367

ASA 0567

ASA 0927

ASA 0929

ASA 0257

ASA 0256

ASA 0177

ASA 0176

ASA 0115

TT 06

TT 07

TT 04

Temperature Switch 50C/ IP 67 (1/2 BSPP thread)

TT 02

optional

Cooler Type
TT 01

asa Electric

progress in cooling
Austria

USA

asahydraulik GmbH
Prager Strae 280
A-1210 Wien
Tel.: +43-1-292 40 20
Fax: +43-1-292 40 70
support@asahydraulik.com

asahydraulik of America Inc.


160 Meister Avenue 20 A
Branchburg, New Jersey 08876
Tel.: +1-800-473 94 00
Fax: +1-908-541 15 50
sales_us@asahydraulik.com

Das könnte Ihnen auch gefallen