SERVICE CERTIFICATION
Certification Information
Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of HVAC systems. System sizes are limited to
12,000 CFM or less airflow.
Qualifications
Y
This is a test and certification for TECHNICIANS in the HVAC industry. The test is designed for top level service
technicians. This test for certification is not intended for the HVAC system designer, sales force, or the engineering
community. To become NATE-certified, you must pass this specialty and a CORE SERVICE exam.
This test will measure what 80% of the Air Distribution candidates have an 80% likelihood of encountering at least once
during the year on a NATIONAL basis.
Suggested requirement is two years of field experience working on Air Distribution systems as a service technician and
technical training for theoretical knowledge.
Test Specifications
Closed Book
2.5 Hour Time Limit
100 Questions Passing Score: PASS/FAIL
Listed are the percentages of questions that will be in each section of the Air Distribution exam.
SECTION AREA DESCRIPTION
SECTION PERCENTAGE
Installation
20%
Service
40%
System Components
25%
Applied Knowledge
15%
American National Standards Institute (ANSI) / Air Conditioning Contractors of America (ACCA) Manuals - Latest Edition
Fibrous Glass Duct Construction Standards, Residential Comfort System Installation Standards Manual, and HVAC Air Duct
Leakage Test Manual
Air Diffusion Council Flexible Duct Performance & Installation Standards
North American Insulation Manufacturers Association (NAIMA) Manuals
Fibrous Glass Duct Construction Standards and A Guide to Insulated Air Duct Systems
International Fuel Gas Code Latest Edition with Addendum
National Fuel Gas Code Latest Edition with Addendum
Exam Copyrights
All testing documents and questions are the copyrighted property of North American Technician Excellence Inc.-NATE. It is forbidden under federal
copyright law to copy, reproduce, record, distribute or display these documents or questions by any means, in whole or part, without written permission
from NATE. Doing so may subject you to severe civil and/or criminal penalties, including imprisonment and/or fines for criminal violations.
Page: 1
Page: 2
Anemometer
Velocity measurement procedures
Gauge calibration
Introduction to airflow in Residential HVAC
Velocity
AIRFLOW PRESSURE MEASUREMENTS
Overview of static pressure measurements
Inclined manometer
Diaphragm type differential pressure gauge Utube manometer
Electronic manometer / pressure measurement
Gauge / meter calibration
Absolute vs. Gauge Pressure
Static pressure
Air pressure measurement terminology
Velocity pressure
Total pressure
AIR VOLUME MEASUREMENTS
Airflow hood
Formulae for determining CFM of air
Formulae for weight of air
Locations for air volume measurements
Airflow volume - CFM / SCFM (Static CFM)
SERVICE
AIR BALANCING
GATHERING DESIGN INFORMATION
Interpreting system design
Interpreting specifications
Interpreting equipment information
Interpreting control data
Modifying system design
PREPARATION OF SYSTEM FOR AIR TESTS
Locating registers, grilles, equipment, controls, and dampers in building walkthrough
Setting dampers for tests
Setting thermostat for tests
Checking for proper fan operation and rotation
Checking for proper static pressure and temperature
PROCEDURES FOR CONDUCTING AIR TESTS
Measurements of each supply outlet - total readings
Measurements of each return inlet - total readings
MAKING ADJUSTMENTS
Adjust airflow to achieve required total airflow Remeasure total supply and return grille airflow Adjust
dampers to obtain design airflow
Re-measure total airflow to verify that it is within +/- 10%
FINAL TEST
Comparing manufacturer's equipment information with test results
Record sheave, pulley, and belt sizes data
Test and record full load motor amperes
Test and record voltage
Test and record motor and fan RPM
Test and record supply and return static pressures
Test and record supply and return air temperatures - heat and cool
COMPLETION OF APPROPRIATE FORMS
HVAC system report
System diagrams
Duct traverse or data pulley forms
Instrument list - including calibration dates
BASIC HVAC SYSTEM ANALYSIS
(C) 2006 NATE All Rights Reserved
Page: 3
NOISE PROBLEMS
Page: 4
Page: 5
Page: 6
Page: 7
Page: 8
Page: 9
Page:
10
Page:
11
Page:
12
Page:
13
Page:
14
Page:
15
Page:
16
SYSTEM STANDARDS
Introduction to industry standards
Industry standards
DESIGN CONSIDERATIONS - LIGHT COMMERCIAL
SPLIT SYSTEMS
System designs - closets, basements, etc.
Air distribution systems
Ventilation - fresh air
Ventilation - equipment
PACKAGED SYSTEMS
System designs
Economizers
Ventilation - equipment
AIR BALANCING
Duct sizing
Blower speed adjustments
Damper position adjustments
Measurement of air flow rate
Fan laws
BIDS AND PROPOSALS
SYSTEM SIZING
Survey of requirements
Selecting equipment
Selecting accessories
PREPARATION FOR AIR DISTRIBUTION PROPOSAL
Understanding forms for proposals and bids
Understanding legal implications of a bid
Page:
17
o = old, n = new
CFM and RPM are
interchangeable.
CFMn
CFMo X RPM
RPMn
0
RPMo
X CFM
0
OR =JSpn
5P;
CFMo
CF )3 BHPn
( CFM
= BHP OR
0
CFM
_ BHPn
0
BHP
Hydronics: AP =Sp,
MAT
0 =Outside
T = Temperature
R =Return
M=Mixed
A=Air
BHPn
BHPo
CFMn
( CFM
)3
----------------------------L-------------------------------------------
AC/Hr x Volume
CFM=------
60min
Vp = <4:05 )2
v = 4005 x .Jvp
Length x Width
144
Area= 1t x radius2
2
A +B
=C
(ft2) =
1t x diameter
576
Circumference
Diameter =
1t
ASP x 100
FR=
TEL
(IWqIOO)
(2650 x I)
mfd=
E
CFM = Velocity (fpm) x Duct Area (ft2)
CFM -
Cr (Series)
(Watts x 3.413)
{ATx 1.08)
1
C1
C2
-+-+
...
+-
TEMPERATURE PRESSURE
CHART-atsealevel
TEMP.
Of
-40
-38
-36
-34
-32
-30
-28
-26
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
oc
-40.0
-38.9
-37.8
-36.7
-35.6
-34.4
-33.3
-32.2
-31.1
-30.0
-28.9
-27.8
-26.7
-25.6
-24.4
-23.3
-22.2
-21.1
-20.0
-18.9
-17.8
-17.2
-16.7
-16.1
-15.6
-15.0
-14.4
-13.9
-13.3
-12.8
-12.2
-11.7
-11.1
-10.6
-10.0
-9.4
-8.9
-8.3
-7.8
-7.2
-6.7
-6.1
-5.6
-5.0
-4.4
-3.9
-3.3
-2.8
-2.2
-1.7
-1.1
-0.6
REFRIGERANT
22
0.6
1.4
2.2
3.1
4.0
4.9
5.9
6.9
8.0
9.1
10.2
11.4
12.6
13.9
15.2
16.5
17.9
19.4
20.9
22.4
24.0
24.9
25.7
26.5
27.4
28.3
29.2
30.1
31.0
31.9
32.8
33.8
34.8
35.8
36.8
37.8
38.8
39.9
40.9
42.0
43.1
44.2
45.3
46.5
47.6
48.8
50.0
51.2
52.4
53.7
55.0
56.2
134a
14.8
13.9
13.0
12.0
10.9
9.8
8.7
7.5
6.3
5.0
3.7
2.3
0.8
0.4
1.1
1.9
2.8
3.6
4.6
5.5
6.5
7.0
7.5
8.0
8.5
9.1
9.6
10.2
10.8
11.3
11.9
12.5
13.1
13.8
14.4
15.0
15.7
16.4
17.0
17.7
18.4
19.1
19.9
20.6
21.3
22.1
22.9
23.7
24.5
25.3
26.1
26.9
404A
407C
4.3
5.3
6.3
7.4
8.5
9.6
10.8
12.0
13.3
14.6
16.0
17.4
18.9
20.4
22.0
23.6
25.3
27.0
28.8
30.7
32.6
33.6
34.6
35.6
36.6
37.7
38.7
39.8
40.9
42.0
43.1
44.3
45.4
46.6
47.8
49.0
50.2
51.5
52.7
54.0
55.3
56.6
58.0
59.3
60.7
62.1
63.5
64.9
66.4
67.8
69.3
70.8
4.6
3.2
1.6
0.0
0.8
1.6
2.5
3.5
4.4
5.4
6.5
7.6
8.7
9.9
11.1
12.3
13.7
15.0
16.4
17.9
19.4
20.2
21.0
21.8
22.6
23.5
24.3
25.2
26.1
27.0
27.9
28.8
29.8
30.7
31.7
32.7
33.7
34.7
35.7
36.8
37.9
39.0
40.1
41.2
42.3
43.5
44.7
45.9
47.1
48.3
49.6
50.8
CONTINUED
410A
10.7
12.0
13.4
14.8
16.2
17.8
19.3
21.0
22.7
24.4
26.3
28.1
30.1
32.1
34.2
36.4
38.6
40.9
43.3
45.8
48.3
49.6
51.0
52.3
53.7
55.0
56.5
57.9
59.3
60.8
62.3
63.8
65.4
66.9
68.5
70.1
71.7
73.4
75.1
76.8
78.5
80.3
82.0
83.8
85.7
87.5
89.4
91.3
93.2
95.2
97.2
99.2
4220
2.3
0.8
0.4
1.2
2.1
3.0
3.9
4.9
5.9
7.0
8.1
9.2
10.4
11.7
12.9
14.3
15.6
17.1
18.5
20.1
21.6
22.5
23.3
24.1
25.0
25.8
26.7
27.6
28.5
29.5
30.4
31.3
32.3
33.3
34.3
35.3
36.4
37.4
38.5
39.6
40.7
41.8
42.9
44.1
45.2
46.4
47.6
48.8
50.1
51.3
52.6
53.9
507
5.4
6.4
7.5
8.6
9.8
11.0
12.2
13.5
14.8
16.2
17.6
19.1
20.6
22.2
23.8
25.5
27.3
29.1
30.9
32.8
34.8
35.8
36.9
37.9
39.0
40.0
41.1
42.2
43.4
44.5
45.7
46.8
48.0
49.3
50.5
51.7
53.0
54.3
55.6
56.9
58.2
59.6
61.0
62.4
63.8
65.2
66.7
68.2
69.7
71.2
72.7
74.3
TEMPERATURE PRESSURE
CHART-atsealevel
TEMP.
oc
32
33
34
35
36
37
38
39
40
42
44
46
48
0.0
0.6
1.1
1.7
2.2
2.8
3.3
3.9
4.4
5.6
6.7
7.8
8.9
10.0
11.1
12.2
13.3
14.4
15.6
16.7
17.8
18.9
20.0
21.1
22.2
23.3
24.4
25.6
26.7
27.8
28.9
30.0
31.1
32.2
33.3
34.4
35.6
36.7
37.8
38.9
40.0
41.1
42.2
43.3
44.4
45.6
46.7
47.8
48.9
51.7
54.4
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
125
130
REFRIGERANT
22
57.5
58.8
60.2
61.5
62.9
64.3
65.7
67.1
68.6
71.5
74.5
77.6
80.8
84.1
87.4
90.8
94.4
98.0
101.6
105.4
109.3
113.2
117.3
121.4
125.7
130.0
134.5
139.0
143.6
148.4
153.2
158.2
163.2
168.4
173.7
179.1
184.6
190.2
195.9
201.8
207.7
213.8
220.0
226.4
232.8
239.4
246.1
253.0
260.0
278.0
296.9
134a
27.8
28.6
29.5
30.4
31.3
32.2
33.1
34.1
35.0
37.0
39.0
41.1
43.2
45.4
47.7
50.0
52.4
54.9
57.4
60.0
62.7
65.4
68.2
71.1
74.1
77.1
80.2
83.4
86.7
90.0
93.5
97.0
100.6
104.3
108.1
112.0
115.9
120.0
124.2
128.4
132.7
137.2
141.7
146.4
151.1
156.0
160.9
166.0
171.2
184.6
198.7
404A
72.4
73.9
75.5
77.1
78.7
80.3
82.0
83.7
85.4
88.8
92.4
96.0
99.8
103.6
109.2
113.3
117.4
121.7
126.0
130.5
135.0
139.7
144.4
149.3
154.3
159.4
164.6
169.9
175.4
181.0
186.7
192.5
198.4
204.5
210.7
217.0
223.4
230.0
236.8
243.6
250.8
257.8
265.1
272.5
280.1
287.9
295.8
303.8
312.1
333.3
355.6
407C
52.1
53.4
54.8
56.1
57.5
58.9
60.3
61.7
63.2
66.1
69.2
72.3
75.5
78.8
101.7
105.6
109.6
113.7
117.9
122.3
126.7
131.2
135.8
140.5
145.4
150.3
155.4
160.5
185.8
171.2
176.8
182.4
188.2
194.1
200.1
206.3
212.5
219.0
225.5
232.2
239.0
245.9
253.0
260.3
287.6
275.1
282.8
290.6
298.6
319.2
340.7
410A
101.2
103.3
105.4
107.5
109.7
111.9
114.1
116.3
118.6
123.2
127.9
132.8
137.8
142.9
148.1
153.5
159.0
164.7
170.4
176.3
182.4
188.6
194.9
201.4
208.0
214.8
221.8
228.9
236.1
243.6
251.2
258.9
266.8
274.9
283.2
291.6
300.3
309.1
318.1
327.2
336.6
346.2
355.9
365.9
376.1
386.4
397.0
407.8
418.8
447.4
477.4
4220
55.2
56.5
57.9
59.3
60.6
62.0
63.5
64.9
66.4
69.4
72.5
75.6
78.9
82.2
96.1
99.8
103.6
107.4
111.4
115.4
119.5
123.8
128.1
132.5
137.1
141.7
146.5
151.3
156.3
161.3
166.5
171.8
177.2
182.7
188.4
194.1
200.0
206.0
212.1
218.4
224.8
231.3
237.9
244.7
251.6
258.8
265.8
273.2
280.6
299.9
320.2
507
75.8
77.4
79.0
80.7
82.3
84.0
85.7
87.5
89.2
92.8
96.4
100.2
104.0
108.0
112.0
116.1
120.4
124.7
129.1
133.7
138.3
143.1
147.9
152.9
158.0
163.2
168.5
174.0
179.5
185.2
191.0
197.0
203.0
209.2
215.5
222.0
228.6
235.3
242.2
249.2
256.3
263.7
271.1
278.7
286.5
294.4
302.4
310.7
319.1
340.8
363.6