Sie sind auf Seite 1von 2

FOX615/612 Technical Data

Universal multiservice platform

FOXMAN-UN network management system

Type tests
Electromagnetic compatibility
EMC

ETSI EN 300386 V1.5.1


IEC 6100062, EN 6100062

power supply
GbE

3 x 10/100/1000 BaseT

1 x LCT Port

IEC 6100064, EN 61000-64

power supply

GbE

2 x GbE / 10 GbE SFP

IEC TS 6100065

12 x alarm input

CESM1

8 x 2 Mbit/s

IEEE 1613

2 x alarm output

Emission

System Control

EN 55022

Immunity

2 x 2 Mhz / 120 synch in


64 x 2 Mbit/s

2 x 2 Mhz / 120 synch out

*SAMO3

TDM transport

IEC 6100042, EN 6100042

48 x 2 Mbit/s G.703/G.704
2 x STM- 4/16 SFP
2 x STM-1/4 SFP
4 x 10/100/1000 BaseT

IEC 6100043, EN 6100043


IEC 6100044, EN 6100044
IEC 6100045, EN 6100045

64 x 2 Mbit/s

GbE
GbE

SAMO2

TDM transport

IEC 6100046, EN 6100046

2 x STM- 4/16 SFP


2 x STM-1/4 SFP
4 x 10/100/1000 BaseT

IEC 61000416, EN 61000416


IEC 61000417, EN 61000417

64 x 2 Mbit/s

GbE
GbE

SAMO1

TDM transport

IEC 61000418, EN 61000418

2 x STM-1/4 SFP
2 x STM-1 SFP
4 x 10/100/1000 BaseT

Shock and vibration

IEC 60 72133, class 3M1


IEC 60 72132, class 2M1

Ambient conditions
Storage

Distance protection relay

TEPI1

Distance protection

Temperature range
Humidity

OPIC1

Differential protection

- 40C + 70C
Clima diagram class 1.2

Transport

Differential protection relay


4 x 2 Mbit/s

ETS 300 01911, class 1.2

4 x IEEE C37.94

ETS 300 01912, class 2.2

Temperature range
Humidity

or ABB proprietary

- 40C + 70C
Clima diagram class 2.2

Operation
4 x 2 Mbit/s

TDM bus 128 x 2 Mbit/s

Gigabit Ethernet star

Gigabit Ethernet star

3 2 x 2 Mbit/s

4 x 2 Mbit/s

LECO1

Data access

LEDS1

Data access

LESU1

Voice subscriber

8 x 64 Kbit/s

Temperature range
Fanless variant
Startup temperature
Humidity

G.703

4 x programmable interface
1 x 10/100 BaseT

V.24 / V.28
X.24 / V.11
V.35
RS-485 2-/ 4-wire

4 x 2 Mbit/s

8 x 2 Mbit/s

LEXI1

Voice exchange

LEDA1

Data access

16 x voice 2-wire a/b


Q.552

DATI1
DSL

12 x voice 2-wire a/b


G.711

8 x voice
2/4-wire E&M

8 x 1pair / 4 x 2pair

1 x 1-pair
1 x 2-pair
SHDSL

1 x 1-pair
1 x 2-pair
SHDSL
8 x 1-pair
4 x 2-pair

8 x 2 Mbit/s

8 x 2 Mbit/s
GbE
GbE

LEDE1

Data access

CEPI1

Circuit emulation

DTM-M

1x

Desktop 1 x IF

Max. 2 x REG

SHDSL

- 25C + 60C
- 25C + 55C
- 25C
max 95%, non-condensing
Clima diagram class 3.2

SFP overview (other types available on request)

Telephony exchange
4 x 2 Mbit/s

ETS 300 01913, class 3.2

REG

STICx / DATI1
SHDSL module

8 x 2 Mbit/s
G.703 / G.704

8 x 2 Mbit/s
G.703 / G.704

1 x 1-pair
1 x 2-pair
SHDSL

Available interfaces:
n x 64 kbit/s (n = 1-32)
- G.703 / G.704, V.24 /
X.21/ V.11 / V.35 / V.36
- 10/100 BaseT

SAMO1

SAMO2/3

STM-1 electrical

S-1.1

L-1.1

L-1.2

X-1.2

U-1.2

CWDM

S-4.1

L-4.1

L-4.2

X-4.2

V-4.2

S-16.1

L-16.1

L-16.2

V-16.2

U-16.2

ETOP1

CESM1

1000 BASE-SX

1000 BASE-LX

1000 BASE-TX

1000 BASE-EX

1000 BASE-ZX

10 GBASE-LR
3 2 x 2 Mbit/s
GbE
GbE

COSI1

Main FOXMAN-UN network management system features

Voice over IP

Full-featured management system for various ABB communication equipment including


1 6 x 2 Mbit/s
GbE
GbE

EPSI1

L2 / L3 Ethernet

FOX615/612, FOX515/512, FOX660 and legacy FOX-U

4 x 10/100 BaseT

Supervision of communication network

GbE

Graphical network display with comprehensive fault management

DSL

GbE

Alarm list

GbE

24 x 10/100/1000 BaseT

ELET1

L2 Ethernet

GbE

12 x GbE SFP

ETOP1

GbE

Security management

L2 Ethernet

GbE

Performance management as per ITU-T G.826

EPOI1

GbE

32 x SHDSL
Ethernet First Mile

*DEFM1

Event list
Configuration management
Full configuration of network elements
Backup of configurations

End to end trail handling


12 x 10/100/1000 BaseT PoE

L2 Ethernet

GbE

(*DEFM1, SAMO3 available in future release)

TDM transport
modules

Protection
modules

Data / voice
modules

Core
modules

Chassis switch modules

www.abb.com/communicationnetworks

Circuit emulation
modules

Ethernet
modules

DSL
modules

1KHA - 001 212 - SEN - 05.14 - Printed in Switzerland


ABB Switzerland Ltd, May 2014. The right to modifications or deviations due to technical progress is reserved.

4 x 2 Mbit/s

4 x protection command
16 x binary signal input
8 x binary signal output
6 x auxiliary relay

Technical data of FOX615/612


Tributary modules

Application

Utility-grade multiservice multiplexer for communication using optical and SHDSL networks

PDH E1 modules

Architecture

Modular design with connectivity on backplane


for hot-pluggable modules

Number of electrical ports

8 x E1 acc. G.703/G.704

TDM bus, Ethernet star

Bit rate

2048 kbit/s 50 ppm

Line impedance

75 asymmetrical or 120 symmetrical

Backplane connection

TDM cross connect (DXC) Non-blocking


PDH

128 x 2 Mbit/s, granularity 64 kbit/s

SDH

VC-12, VC-3, VC-4

Ethernet crossbar

Capacity

Distributed switching architecture with centralised


64 Gbps switching fabric for intermodule switching

Communication technology

PDH, SDH, IP/Ethernet, EoS, CES

Equipment protection
1+1 HW Protection


Traffic protection

CESM1 (Warm standby)


LEDA1, LEDS1, EPSI1 (VRRP), SAMO2, SAMO3,
LEDE1 (Combiner), CEPI1 (Combiner)

1+1 path protection n x 64 kbit/s TEPI1, OPIC1, LEDA1, LEDS1, LECO1, LESU1

SNCP (VC-12, VC-3, VC-4)

SAMO1, SAMO2, SAMO3, LEDE1

MSP (STM-1, STM-4, STM-16)

SAMO1, SAMO2, SAMO3

LAG

CESM1

Chassis switch

RSTP, MSTP

Aggregation bit rates




SDH
Ethernet
SHDSL, net capacity

Feature: STM-1, STM-4, STM-16


GbE, 10 GbE
n x 64 kbit/s or 2 Mbit/s (n = 3 ... 32)

Power supply

LEDE1 E1 G.703

OPIC1 differential protection


Traffic protection

SNCP on 64 kbit/s and P12 layer for transparent E1


channels

Tributary or aggregate interface

Features

Circuit emulation modules


CEPI1 CESoP / E1 G.703


Number of protection ports

4 x differential protection ports with SFP cages for:


MM SFP 850 nm, LC/PC
SM SFP 1310 nm, LC/PC


Bit rate


Line-rate 2048 kbit/s acc. ITU-T G.704


IEEE C37.94 payload 63 - 768 kbit/s (1 - 12 time
slots)
ABB TPE payload 64 192 kbit/s (1 3 time slots)


Protection features


Standardized IEEE C37.94 connection to


protection relays
Proprietary SFC-protocol connection to ABB
1+1 path protection, bidirectional switching

Number of electrical ports

8 x E1 acc. G.703/G.704

Bit rate

2048 kbit/s 50 ppm

TEPI1 distance protection

75 asymmetrical or 120 symmetrical

Circuit emulation using SAToP acc. IETF PWE3 for


64 kbit/s and P12 layer
Up to 8 P12 signals over packet

Line impedance


Features

VolP telephony modules


COSI1

Number of ports


Features



Most used SFPs


Teleprotection modules

Up to 912 PSTN subscribers (no physical ports)


SIP gateway for voice over IP of PSTN ports
Codec G.711 and G.729A support including silence
supression.
Fax service acc. T.38, DTMF acc. RFC 2833,
SIP authentication acc. RFC 2617

Data access modules

Traffic protection

Number of protection ports

4 x protection commands

Connector

Terminal block for direct wiring

Protection voltage

24 VDC 250 VDC, programmable

also available: CWDM, DWDM; single-fiber, electrical signal


(RJ45) (e.g. electrical GbE)

Optical SFP for STM-1 ports


Wavelength

nm

L-1.2

CWDM
X-1.2

CWDM
U-1.2

1310

1310

1550

1550

1550

dBm

-15

-5

-5

Guaranteed sensitivity Rx

dBm

-28

-34

-34

-35

-45

dB

13

29

29

35

50

dBm

-8

-8

-10

-3

-10

S-4.1

L-4.1

L-4.2

CWDM
X-4.2

CWDM
V-4.2
1550

Attenuation range EoL


Max. receiving power
Optical SFP for STM-4 ports

1310

1310

1550

1550

Min. output power Tx

Wavelength

dBm

nm

-15

-3

-3

Guaranteed sensitivity Rx

dBm

-28

-28

-28

-29

-37

dB

13

25

25

30

38

dBm

-8

-8

-8

-8

-9

S-16.1

L-16.1

L-16.2

V-16.2

U-16.2

Attenuation range EoL


Max. receiving power

Protection link addressing


Supervision of transmission time
Logical combinations (OR, AND) for T-off
Command drop & insert
Event recorder
IRIG-B time stamping
Aux. relay outputs


Traffic protection

1+1 path protection, typically 3.5 ms switch-over


time

Attenuation range EoL

16 x binary signal input

Max. receiving power

8 x binary signal outputs

Optical SFP for Ethernet ports

24 VDC onboard

Auxiliary power supply

L-1.1

Min. output power Tx

Protection functions







Number of auxiliary ports

S-1.1

Optical SFP for STM-16 ports

1310

1310

1550

1550

1550

Min. output power Tx

Wavelength

dBm

nm

-5

-5

-2

Guaranteed sensitivity Rx

dBm

-18

-18

-28

-30

-30

dB

13

13

26

31

35

dBm

-9

-9

-9

-9

1000
BASESX (MM)

1000
BASELX

1000
BASEEX

1000
BASEZX

1000
GBASELR

Input voltage range


48 VDC, 60 VDC or external power converter


- 39.5 VDC - 72 VDC


Max. input current

30 A (FOX615)
16 A (FOX612)


Number of legacy data ports

4 x V.11/X.24, V.35, V24/V.28


RS-485 (2-wire and 4-wire)

1+1, hot standby

Options




1+1 path protection


Subrate 64 kbit/s (future release)
Point-multipoint, multipoint-multipoint data confer-
encing with 4, 8 or 16 participants
Performance monitoring acc. ITU-T G.826

Number of SHDSL interfaces

8 x 1-pair or 4 x 2-pair

Traffic protection

1+1 path protection, shared protection ring

Line code

16 Trellis coded-PAM according G.991.2

Equipment protection

1+1 HW protection for data conferences


UNIDA, DATAx, DATI1 / DTM-M
0 600 kbit/s, oversampling for V.11 / X.24, V.35,

n x 64 kbit/s duplex via 1 or 2 copper pair,


n = 3 ... 32

Channel-Associated Signalling

Data interface compatibility


Bit rate


Line rate

CAS


Service rate

n x 64 kbit/s duplex via 1 or 2 copper pair,


n = 1 ... 32

CES

Circuit Emulation Service

CESoP

Circuit Emulation Services over Packet

Transmission range

Up to 25 km

CMI

Code Mark Inversion

Transmission mode

1 pair or 2 pair (cable depending)

CWDM

Coarse Wavelength Division Multiplexing

Traffic protection

1+1 path protection

DCN

Data Communication Network

Point-multipoint
Tributary or aggregate interface
Remote powering

DSL

Digital Subscriber Line

CWDM

Coarse Wavelength Division Multiplexing

DSL

Digital Subscriber Line

DTMF

Dual-Tone Multi-Frequency

DWDM

Dense Wavelength Division Multiplexing

DXC

Digital Cross Connect

ECC

Embedded Communication Channel

EMC

Electro Magnetic Compatibility

EoL

End of Life

EoS

Ethernet over SDH

FE

Fast Ethernet

Hardware protection

Standardization

PDH / SDH


ITU-T G.702, G.703, G.704, G.706


G.707, G.7041, G.7042
G.711 - G.715, G.732, G.736, G.737
G.742, G.821, G.823, G.826

G.692, G.694.1, G.694.2, G.957

Optical parameters

Ethernet

IEEE 802.1D, 802.1Q, 802.1p, 802.15, 802.39d


802.1w, 802.3af, 802.3at, 802.3z, 802.1s, 802.3ad
RFC 2328, RFC 2453, 802.1ad


Safety

IEC 609501, EN 609501


IEC 60825

Mechanical dimensions FOX615


Shelf with front cover (WxHxD)

465 x 309 x 304 mm

Cable tray (WxHxD)

465 x 89 x 240 mm

Heat deflection shield (WxHxD)

465 x 89 x 237 mm, optional

Number of mechanical slots

21, incl. 1 (2) for CESM1

Mechanical dimensions FOX612


Shelf with front cover (WxHxD)


and fan unit

465 x 176 x 304 mm

Number of mechanical slots

8, incl. 1 (2) for CESM1

LEDS1

RS-485
0 ... 96 kbit/s: oversampling for V.24/V.28
For all interface types:
0.6 38.4 kbit/s, a-/synchronous
48, 56, 64 kbit/s, synchronous

Ethernet port

1 x 10/100 BaseT
RJ45 electrical


Ethernet features

Bridge over PDH functionality


PPP, HDLC encapsulation


Ethernet interface compatibility

ETER1, EPSI1, LAWA4, OPTIF, DATAx


DATI1 / STICx / DTM-M

LECO1 64 kbit/s G.703


Number of ports

8 x 64 Kbit/s according to ITU-T G.703

Bit rate

64 kbit/s codirectional

Traffic protection

1+1 path protection


Auxiliary signal functions

Logical combinations (OR, AND)


Alarm card functionality for 3rd party equipment
(ALCAR)

Wavelength

nm

850

1310

1310

1550

1310

Typical distance

km

0,5

40

70

10

SHDSL modules
DATI1

Features


*DEFM1 Ethernet first mile

Number of SHDSL interfaces

32 x 1-pair or pair bonding up to 4 pairs

Line code

16 Trellis coded-PAM according G.991.2


Line rates




Transmission range

Features

TCPAM-16:
n = 3 ... 60 x 64 Kbit/s (3840 Kbit/s) per pair
TCPAM-32:
n = 12... 89 x 64 Kbit/s (max. 5696 Kbit/s) per pair
Up to 25 km
Member of chassis switch PPPoE

Abbreviations

Core modules

Ethernet switching and routing modules

Remote desktop modules

FXS

Foreign eXchange Station

CESM1 control unit

ELET1 L1/L2 Ethernet

DTM-M SHDSL desktop

GbE

Gigabit Ethernet

1 x 1-pair or 2-pair

GFP

Generic Framing Procedure

HDLC

High-Level Data Link Control

IF

InterFace

IP

Internet Protocol

LAG

Link Aggregation

LCAS

Link Capacity Adjustment Scheme

24 x 10/100/1000 BaseT, RJ45 connector


Features

Member of chassis switch


Two-slot unit
Chassis switch features


Number of access ports

fixed G.703/G.704 120 or 1 modular interface (G.703/G.704 75 , V.24, X.21/V.11, V.35,


V.36, Ethernet)

16 Trellis coded-PAM according G.991.2

Number of physical ports

Management interfaces

10/100/1000 BaseT (IEEE 802.3)


DCC-interfaces

Synch I/O

2048 kHz: 2 synch inputs, 2 synch outputs

Alarm I/O

12 alarm inputs, 2 alarm relay outputs

Main features

Central processing unit, DCN IP routing, Ethernet


crossbar, Ethernet aggregation
1+1 equipment protection, (warm standby)

ETOP1 L1/L2 Ethernet

Number of Ethernet ports



3 x 10/100/1000 BaseT
2 x GbE/10 GbE, SFP + based
1 x LCT Port

Ethernet features


Ethernet aggregation unit


GbE/10 GbE uplink
ERPS acc. ITU-T G.8032v2
LAG acc. IEEE 802.1AX (future release)

Chassis switch features







Control of chassis switch


Distributed switching architecture with centralised
64 Gbps Ethernet crossbar for intermodule switching
RSTP, MSTP acc. 802.1D/802.1Q
VLAN Q-in-Q
ERPS acc. ITU-T G.8032v2
LAG acc. IEEE 802.1ad

FAMO1 fan unit

For FOX615

Number of fans

10

Operation

Temperature controlled

Traffic protection

Number of physical ports

Features
Traffic protection

Number of physical ports



Power over Ethernet

12 x 10/100/1000 BaseT, RJ45 connector with


Power over Ethernet (PoE)
According to ITU-T 802.3af and 802.3at
Max. 84 W per module
Max. 30 W per port (PoE+)

Features
Traffic protection

Number of physical ports

4 x 10/100/1000 BaseT RJ-45 connector

Number of Ethernet ports


SDH features


128 x 128 VC-4 HO cross connect


1008 x 1008 VC-12 LO cross connect
Max. 64 x P12 termination to TDM Bus
80 x AU4 backplane connectivity


Ethernet features

Member of chassis switch


Max 32 x EoS mappers up to 2.4 Gbps
Onboard 10 Gbps VLAN-aware switch


Traffic protection

SNCP/MSP for SDH traffic (inter & intra module)


GFP/VCAT/LCAS for EoS mappers
Chassis switch features

1+1 HW Protection

Equipment protection

Multi Link Point to Point Protocol

MM

Multi Mode

MSP

Multiplex Section Protection

MSTP

Multiple Spanning Tree Control

NE

Network Element

NT

Network Termination

OHC

Overhead Channel

OSPF

Open Shortest Path First

PAM

Pulse Amplitude Modulation

PDH

Plesiochronous Digital Hierarchy

SHDSL REG SHDSL regenerator

Member of chassis switch

Types

Indoor (IP21), outdoor (IP54), underground (IP68)

Chassis switch features

Power options

Local 48 VDC power or remote power feeding

4 x 10/100 BaseT, RJ45 connector

Configuration and management (software packages)

Point to Point Protocol

OSPF v2 acc. RFC 2328, RIP v2 acc. RFC 2453


Static routing, VRRP, Inter-VLAN routing

FOX615, FOX612

PSTN

Public Switched Telephone Network

FOXMAN-UN network management system

PWE

Pseudo Wire Emulation

MLPPP, RSTP, VRRP, OSPF v2, RIP v2

RIP

Routing Information Protocol

RSTP

Rapid Spanning Tree Protocol

Rx

Receiver

Traffic protection


Compatibility

ETER1, LAWA4, OPTIF, DATAx, LEDS1,


DATI1 / STICx / DTM-M

1+1 HW protection

Equipment protection


Number of ports

12 x 2-wire FXO
according ITU-T Q.522 (Z-interface)

Coding

A-law according ITU-T G.711

Input (from exchange)

- 5 ... + 4 dBr, programmable

Output (to exchange)

- 7.5 ... - 3 dBr, programmable

Nominal impedance

Complex or 600

Channel bandwidth

300 ... 3400 Hz


Signalling & functionality

Seizure, ringing, ringing off, transmission of flash


pulses, pulse dialling, DTMF without accompanying
signal, earth key, charging using 12/16 kHz pulses

LEDA1 voice and E&M



Number of ports

8 x 2-/4-wire voice channels


according ITU-T G.712 - G.715

Coding

A-law according ITU-T G.711

Input (from exchange)

- 16.0 ... + 9.5 dBr, programmable

Output (to exchange)

- 20.0 ... + 7.0 dBr, programmable

Nominal impedance

600

Channel bandwidth

300 ... 3400 Hz


Signalling

E, M, E, M
Support of signalling types I to V

Traffic protection

1+1 path protection, shared protection ring

Equipment protection

1+1 HW protection for voice conferences


Features



LESU FXS

Number of SDH ports




Number of Ethernet ports
SDH Features



Ethernet Features


Traffic protection


Equipment Protection
Number of electrical ports
Bit rate
Line impedance
Traffic protection

Features


Number of ports

16 x 2-wire FXS interface


according ITU-T Q.552

Coding

A-law according ITU-T G.711

Input (from subscriber)

- 4.0 ... + 4.0 dBr, programmable

Output (to subscriber)

- 10.0 ... + 0.0 dBr, programmable

Nominal impedance

Complex or 600 , programmable

Channel bandwidth

300 ... 3400 Hz


Signalling & functionality

Managed equipment

Features

Graphical display of network


Network element supervision
Fault & configuration management

Linux Red Hat

Operating system

Options




Performance management, ITU-T G.826


Multiple working places
Main - standby solutions
Trail handling (networking package)
Synchronization map
SNMP northbound/southbound

SDH

Synchronous Digital Hierarchy

SHDSL

Single pair High-speed Digital Subscriber Line

SETS

Synchronous Equipment Timing Source

SFP

Small Form-factor Pluggable

SIP

Session Initiation Protocol


Managed equipment

FOX515, FOX512, FOX615, FOX612, FOX660,


ETL600, AFS670, AFR670, AG100 and other
equipment

SM

Single Mode

SNCP

Sub-Network Connection Protection

SNMP

Simple Network Management Protocol

STM

Synchronous Transport Module

STP

Spanning Tree Protocol

TCPAM

Trellis-Coded Pulsamplitudemodulation

TDM

Time Division Multiplex

TPE

TeleProtection Equipment

Tx

Transmitter

VC

Virtual Container

VCAT

Virtual Concatenation

VLAN

Virtual LAN

VRRP

Virtual Router Redundancy Protocol

Note: All modules use one mechanical slot, except where otherwise stated.

Exeptions are the fanless modules CESM1-F, ETOP1-F, SAMO2-F.

Up to 10 x voice conferences with max. 32 partici-


pants per unit
Point-point, point-multipoint and
multipoint-multipoint topologies

*SAMO3 optical/electrical SDH & E1 G.703


4 (2 x STM-1/4, 2 x STM-4/16 SFP-cage)
SFPs available with optical LC/PC (STM-1/4/16) or
electrical DIN 1.0/2.3 75 (STM-1) connector
4 x 10/100/1000 BaseT RJ-45 connector
128 x 128 VC-4 HO cross connect
1008 x 1008 VC-12 LO cross connect
Max. 64 x P12 termination to TDM Bus
80 x AU4 backplane connectivity
Member of chassis switch
Max 32 x EoS mappers up to 2.4 Gbit/s
Onboard 10 Gbit/s VLAN-aware switch
SNCP/MSP for SDH traffic (inter & intra module)
GFP/VCAT/LCAS for EoS mappers
Chassis switch features
1+1 HW Protection
48 x E1 acc. G.703/G.704
2048 kbit/s 50 ppm
75 asymmetrical or 120 symmetrical
SNCP on 64 kbit/s and P12 layer for transparent
E1 channels
Tributary or aggregate interface
Two-slot unit

Management Information Base

MLPPP

16 Trellis coded-PAM according G.991.2

LEXI1 FXO

4 (2 x STM-1/4, 2 x STM-4/16 SFP-cage)


SFPs available with optical LC/PC (STM-1/4/16) or
electrical DIN 1.0/2.3 75 (STM-1) connector

Modified Code Mark Inversion

MIB

Line code

Analogue telephony modules


Number of SDH ports

MCMI

115/230 VAC: 88 VAC 264 VAC, 50/60 Hz


48 VDC: - 38 VDC - 60 VDC

Power over Ethernet

SAMO2 optical/electrical SDH

Remote powering

PPP

Above equipment, no mechanical slot required

SNCP/MSP for SDH traffic (intra module)


LCAS for Ethernet traffic

Options


Local power supply

PoE

Temperature controlled


Traffic protection

Windows 2000, Windows XP


Windows Vista, Windows 7

Installation

L1-Ethernet over SDH functionality


Support of GFP / VCAT / LCAS

MCAS Mercury-CAS

Operating system

Operation


Ethernet features

Up to 25 km

According to IEEE 802.1D and 802.1Q


Traffic prioritization according to IEEE 802.1p
Up to 8 independent switching instances

18 x 18 VC-4 HO cross connect


36 x 36 VC-3 or 693 x 693 VC-12 LO cross connect
Max. 64 x P12 termination to TDM BUS

Transmission range

L2-switching features


SDH features

Linear Trail Protection


L3-routing features

4 x 10/100/1000 BaseT RJ-45 connector

Line Termination

LTP

Remote and local configuration


Remote and local analysis & error detection
Remote supervision

LT

Features

Number of fans

4 (2 x STM-1, 2 x STM-1/4 SFP-cage)


SFPs available with optical LC/PC (STM-1/4) or
electrical DIN 1.0/2.3 75 (STM-1) connector

n x 64 kbit/s duplex via 1 or 2 copper pair,


n = 1 ... 32

FOXCST configuration tool


Number of SDH ports


Service rate

64 x TDM bus access


Max. 8 x P12 (n x 64 kbit/s granularity) or
max. 16 x P12 (n x 128 kbits/s granularity)
PPP / MLPPP / HDLC traffic encapsulation

for FOX612

SAMO1 optical/electrical SDH

n x 64 kbit/s duplex via 1 or 2 copper pair,


n = 3 ... 32


Number of PDH ports


FAMO2 fan unit

SDH aggregate modules

Line code


Line rate

EPSI1 L2/L3 Ethernet

Above equipment,
1HU, no mechanical slot required

Number of Ethernet ports

Member of chassis switch


Chassis switch features

EPOI1 L2 Ethernet with PoE


Installation

Aggregate modules

12 x GbE, SFP based

Number of transmission ports

V5.x, MCAS, carrier adapter, phone-exchange


Full test for subscriber lines is included
Ring over b-wire

We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.
Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Switzerland Ltd, Power Systems, 2014.

(*DEFM1, SAMO3 available in future release)

For more information please contact:


ABB Switzerland Ltd
Power Systems
Bruggerstrasse 72
5400 Baden, Switzerland
Phone: +41 58 585 77 44
Fax:
+41 58 585 55 77
E-Mail: communication.networks@ch.abb.com
www.abb.com/communicationnetworks

1KHA - 001 212 - SEN - 05.14 - Printed in Switzerland


ABB Switzerland Ltd, May 2014. The right to modifications or deviations due to technical progress is reserved.