Beruflich Dokumente
Kultur Dokumente
Julio de 2008
Sujeto a cambios
The CN numbers in the following table are the connector numbers on the IOB.
No.
SW1
S9
Sensor Name/
Sensor Board Name
Activ
e
CN
CN204/1
Duplex Door
ID Sensor: M
ID Sensor: C
ID Sensor: Y
ID Sensor: Front
CN211/1
CN211/2
ID Sensor: Rear
CN211/3
S1
CN232/B9
Condition
Symptom
Open
Shorted
Open
Shorted
CN211/
Open/
7, 11
Shorted
CN211/
Open/
8, 12
Shorted
CN211/
Open/
9, 13
Shorted
Open/
Shorted
Open/
Shorted
Open/
Shorted
SC400
SC258
SC400 / SC258
SC258
131
No.
Sensor Name/
Sensor Board Name
Activ
e
CN
S12
Registration Sensor
CN224/A2
S28
CN222/A2
S29
CN222/ A5
S30
CN222/ A8
S31
CN222/ A11
CN207/A1
S24
S25
S26
S27
CN207/B9
L
Condition
Symptom
Open
Shorted
Jam A, B (Jam1)
Open/
Shorted
Open/
Shorted
Open/
Shorted
Open/
Shorted
SC380/SC396
SC381/SC397
SC382/SC398
SC383/SC399
Open
Shorted
CN207/
B12
CN207/
B15
S32
S18
S21
Paper End
S24
Sensor 1, 2
S20
S23
132
H/L
CN208/11
CN230/A7
Open/
Shorted
SC443
Open
Shorted
Jam A, B (Jam1)
Open
Shorted
CN230/
A10, B10
CN230/
Open/
A13, B13
Shorted
SC501, SC502
No.
S21
S14
S15
S16
S17
SW4
S11
SW2
Sensor Name/
Sensor Board Name
Activ
e
CN
Symptom
Open
Shorted
Jam A, B (Jam1)
CN224/
Open/
B2, B5
Shorted
CN224/
Open/
B10, B13
Shorted
CN230/B7
B16, B17,
B19, B20
Shorted
Open/
Shorted
Shorted
A15
CN232/
Open
B12
Shorted
S8
CN232/B6
S6
CN232/A8
S7
Open
CN232/
S10
Open
CN224/A9
CN232/
L
Condition
Open
Shorted
Jam C (Jam 1)
Open
Shorted
Jam Z (Jam 1)
CN232/
Open
A11
Shorted
Jam Z (Jam 1)
133
No.
Sensor Name/
Sensor Board Name
Activ
e
S35
TD Sensor - K
S36
TD Sensor - M
S37
TD Sensor - C
S38
TD Sensor - Y
S4
S13
SW4
CN
CN227/A7
S33
134
Temperature/
Humidity Sensor
Open/
Shorted
CN227/
Open/
A15
Shorted
CN227/B7
Open/
Shorted
CN227/
Open/
B15
Shorted
CN204/12
SC372
SC373
SC374
SC375
Jam C (Jam 19)
Shorted
Jam C (Jam 1)
Open
Shorted
Open
Shorted
CN224/A7
A11, A12,
A13, A15
Symptom
Open
CN224/A5
CN224/
SW6
Condition
Open/
Shorted
CN231/
Open/
25, 27
Shorted
SC498
Printed image has some
problems such as rough
No.
Sensor Name/
Sensor Board Name
Activ
e
CN
Condition
Symptom
image, dirty background,
weak image or poor fusing.
S34
TH2
TH1
S3
S5
Thermopile
Thermistor
- Heating Roller
Thermistor
- Pressure Roller
Paper Exit Sensor
CN209/16
CN212/22
CN212/18
CN204/9
S43
S39
Scanner HP Sensor
S41
S42
Open/
Shorted
Open/
Shorted
Open/
Shorted
SC541
SC551
SC561
Open
Shorted
Jam C (Jam 1)
Open
Shorted
CN204/15
CN313/14
Open/
SIO
Shorted
CN313/11
Open/
SIO
Shorted
CN313/8
Open/
SIO
Shorted
CN313/5
Open/
SIO
Shorted
CN313/2
Open/
SIO
Shorted
CN318/2
Open
SC120
135
No.
Sensor Name/
Sensor Board Name
Activ
e
S40
S2
CN
Condition
Symptom
SIO
Shorted
SC121
CN318/5
Open/
SIO
Shorted
CN204/6
Open/
Shorted
Fuse
136
Rating
115V
220V - 240V
FU1
15A/125V
8A/250V
FU2
10A/125V
6.3A/250V
FU3
2A/250V
1A/250V
FU4
1A/250V
1A/250V
FU5
5A/250V
5A/250V
FU6
2A/250V
2A/125V
FU7
10A/125V
10A/125V
FU8
10A/125V
10A/125V
FU9
6.3A/125V
6.3A/125V
FU10
6.3A/125V
6.3A/125V
FU11
6.3A/125V
6.3A/125V
FU12
6.3A/125V
6.3A/125V
Fuse
Rating
115V
220V - 240V
FU13
6.3A/125V
6.3A/125V
FU14
5A/250V
5A/250V
IH Inverter
Fuse
FU1
Rating
115V
220V - 240V
15A/125V
8A/250V
FU2
115C
No response
FU3
115C
No response
FU4
1A/250V
For continued protection against risk of fire, replace only with same type and rating of fuse.