KMP7020/KMP7021 KMP7030
Digital RCD Tester
KMP7020
KMP7021
Fast testing
Instant reading
Large display
Backlight display
KMP7010
KMP7036
Insulation-Continuity Tester
17B
Carry case included
with both kits
+
KMP7030 Earth Loop Impedance Tester
+
KMP7036 Insulation Tester
5
KMP7021 RCD Tester
KTS1625
n Continuity Functions
- Continuity resistance @ 200mA
n Insulation Function
- Selectable test voltages 250V, 500V & 1000V
n Line / Loop Impedance Functions
- Prospective earth fault current
- Prospective short-circuit current
- Non Trip Loop test
- Fast testing
n RCD Functions
- Three levels of trip currents (X, X1, X5)
for complete range of testing applications
- Phase switch selection 0 and 180 for
positive and negative semi-cycle testing
- RCD ramp test
- Tests time delayed RCDs (S-type)
- Test pulse sensitive (DC) RCDs
- Auto RCD test
n
Designed to allow testing to BS7671
IEE 17th Edition regulations
n
Voltage and frequency measurements
n
Instant correct wiring status check
n
Dual measurement result display
n
Large, backlit display
n
Low battery indication
n
Safety CAT III 300V
KMP7100
n
n
SL17B
TP1625
SL7030
KP1700
SL17E
GT-400-UK
Electrical Testers
VP-700-E
VP-710-E
Indication of polarity
Additional Features
n No unawared tripping of RCD
n No battery required
n Quick single-hand on 19 mm contact distance outlets,
without removing test probe from instrument
n Built and certified according latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011
Additional Features
n Quick single-hand on 19 mm contact distance outlets,
without removing test probe from instrument
n Torch function via white LED
n Built and certified according latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011
VP-720-E
10
Additional Features
n Vibration function
n Test of 30mA RCD by both push buttons,
avoids unintended tripping of RCD
n Torch function via white LED
n Quick single-hand test on 19 mm
contact distance sockets
n Built and certified according to latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011
VP-440 RT
Non-contact Voltage
Tester
n
ECB50A-E
Non-contact, optical
detection of AC voltages
n
50-1000V AC
T
ransmitter signal displayed
optically and acoustically
by the receiver
T
ransmitter with integrated
BS1363 UK plug enabling easy
connection to mains socket
Continuous sensitivity
2050-D
VP-450-E
Non-contact Voltage
Tester
n
50-600V AC
detection of AC voltages
Voltage Testers
adjustment of receiver
Integrated flashlight
Additional Features
n
On/off switch
11
Clamp-on Meters
12
ACD-14 PLUS
ACDC-400
Additional Features
n Dual display
n A measurement range for direct
measurement of ionisation
currents in heating systems
ACD-20SW
Additional Features
n AC/DC clamps are also suitable
for automotive applications,
emergency power supplies
and solar technology
n Backlight
ACDC-100
Additional Features
180 degree rotating head
for the perfect display
n Advanced VoltTect noncontact voltage detection
Clamp-on Meters
Additional Features
Large, clear display
13
ACD-50NAV
LH41
Additional Features
Real effective value measurement AC+DC (TRMS)
Contactless voltage detection
Measurement point illumination by means of white LED
n
n
n
ACDC-54NAV
14
Additional Features
n Real effective value measurement AC+DC (TRMS)
n Contactless voltage detection
n Measurement point illumination by means of white LED
Current measurement
from 1 mA AC and DC
Jaw opening: 19 mm
Integrated 5 s measurement
memory (data hold)
Auto power-off
Additional Features
n
Minimum resolution: 1 mA
AC50A
Integrated measurement
memory (data hold)
Jaw opening: 30 mm
Auto power-off
Additional Features
n
Range of applications:
measurement of leakage
or fault currents, current
consumption of devices in
(customer) service sector
without breaking the circuit
Digital Multimeters
15
AM-500-EUR
AM-510-EUR
DMM
A
utoranging feature
automatically sets up
voltage, current, and
resistance ranges for you
n V
oltage up to 600V AC/DC
n R
esistance
n A
udible continuity
n D
iode test
n D
ata hold
n A
uto power off
n L
ow battery warning
n
600V AC/DC
10A AC/DC
Temperature measurement
measurement
range selection
Built-in flashlight
Contents
Contents
Test leads
AAA x 2
Users manual
Users manual
AM-520-EUR
DMM
n
n
n
7 50V AC/DC
10A AC/DC
Capacitance and frequency
AM-530-EUR
DMM TRMS
10A AC/DC
TRMS measurement
measurement
measurement
Temperature measurement
Temperature measurement
range selection
Auto power off
Built-in flashlight
Built-in flashlight
Contents
16
range selection
Contents
Test leads
Test leads
1 x Temperature probe
1 x Temperature probe
Carrying case
Carrying case
Users manual
Users manual
Hang strap
Hang strap
DMM
AM-550-EUR
DMM TRMS
1000V AC/DC
10A AC/DC
n Low pass filter for variable
frequency drives
n Capacitance and frequency
measurement
n Temperature measurement
n Automatic and manual
range selection
n Auto power off
n Non-contact voltage detection
n Built-in flashlight
Contents
n Model AM-540 EUR
n Test leads
n 2 x Temperature probe
n Carrying case
n 1 x 9V (6F22) battery (installed)
n Users manual
n Hang strap
Contents
n Model AM-550 EUR
n Test leads
n 2 x Temperature probe
n Carrying case
n 1 x 9V (6F22) battery (installed)
n Users manual
n Hang strap
DM73C
1000V AC/DC
10A AC/DC
n TRMS measurement
n Low pass filter for variable
frequency drives
n Capacitance and frequency
measurement
n Temperature measurement
n Automatic and manual
range selection
n Non-contact voltage detection
n Built-in flashlight
PM55A
Digital Multimeters
AM-540-EUR
Digital Multimeter
AutoTect feature directs the
meter to know if it is measuring
AC volts, DC volts or resistance
with no user interface
n The AutoTect feature has
lower input impedance which
zero out ghost voltages
n Measures AC/DC current,
capacitance, frequency,
continuity with beeper plus
includes Voltect, a built-in,
non-contact voltage detector
n Large oversize digital display
n Protective silicon holster
included, attached test
leads, battery, deluxe
carry case and manual
n One-year, no-hassle warranty
n
17
Temperature Measurement
18
IR-730-EUR
IR-720-EUR
IR-750-EUR
Temperature Measurement
IR-710-EUR
19
IR-450-EUR
IR608A
Infrared Thermometer
Laser Pointer
Selectable F / C
Holds temperature
measurement
n
Switchable between C
and F measurement
Non-contact temperature
Integrated measurement
memory (data hold)
Backlight
Auto power-off
Additional Features
n
Laser-based targeting
TMD-50
Thermometer
TMD-50, Type K
Dual (Temperature
measurement with connection
for two sensors)
n -60 to 1350 C, -58 to 2498 F
n Measurement of the
temperature difference
n Connection for two
temperature sensors type K
n Switchable for measurement
in C or F
n Integrated measurement
memory (Data Hold)
n MIN/MAX and relative
value measurement
n Measurement of the
average temperature
n Backlit display
n Auto-Power-Off
TH-3
Relative Humidity
Temperature Meter
20
Additional Features
n Best precision 0.1%
n T1-T2 (temperature
difference)
n Shock and impactresistant by standard
protective cover
Dual display
Min/Max readings
Data Hold
n
protective cover
n
One-year warranty
21
LAN-1
LM-100
Light measurement
0 -200,000 lux
Silicon sensor
Integrated measurement
TMA10
Anemometer Thermometer
Anemometer with remote vane
LM-120
Silicon photodiode
22
PRM4
3-phase sequence
and open phase check
n Motor shaft rotation indication
protected by CAT III circuitry
n CAT III 600V rated for
both testing segments
n Meets current EN61010 safety
requirements, CSA, EN61557-7
n Supplied with three CAT III
rated color coded large
alligator clips and test leads
n Zippered carrying case
for portability
TACH20
Combo Tachometer
LT-10-EUR
Lamp Tester
Measures rotational
and surface speed
n Built-in memory
n Digital Display
n Auto power off function
n Easy to select units
and mode functions
n Contact and non-
contact measurement
n Select rpm using infrared
beam or adapter: m/min, m/sec,
ft/min, ft/sec, in/min, m, ft, and in.
n Includes 6 Adapters, Carrying
Case, Reflective Tapes,
Batteries and User Manual
n
Increase productivity
by minimising trips up
and down a ladder
Ultra-compact design
SM-10
for portability
Sound Meter
retractable antenna
n
PQ55A
Others
TX900
Microwave Leakage
Detector
n
Temperature compensation
Auto-zero
23
Technical Specification
Multi-Function Installation Testers
KTS1625
KMP7100
Insulation Resistance @
250V/500/1000V (Test
Current 1mA)
Operating Voltage
230Vac, 45Hz ~ 65 Hz
+10% to -15%
0.01 ~ 19.99
@ Nominal Test
Current 25A
20.0 ~ 199.9
@ Nominal Test
Current 2.3A
200 ~ 1999
@ Nominal Test
Current 15mA
0.01 ~ 19.99
20.0 ~ 199.9
0.0 ~ 199.9 /
1999 / 19.9kA
Continuity @ IN 200mA,
Uo=5Vdc (Nominal)
0.00 ~ 199
(Buzzer threshold: 20)
AC Voltage Measurement
0Vac ~ 400Vac
Operating Voltage
(Loop and RCD)
230Vac, 45Hz ~ 65 Hz
+10% to -15%
Loop Impedance
(L PE) @ 25A
10/30/100/300/500mA
0% to 10% @
1n and 5n
-10% to 0% @ n
0 ~ 2000ms
(10/30/100/300/500mA)
0 ~ 1000ms (selective)
(10/30/100/300/500mA)
10/30/100/300/500mA
0% to 10% @
1n and 5n
-10% to 0% @ n
0 ~ 1000ms
(10/30/100/300mA)
0 ~ 2000ms
(10/30/100/300/500mA)
0 ~ 40ms
(10/30/100mA)
0 ~ 500ms (selective)
(10 / 30 / 100 /
300 / 500mA)
X / X1 / X5 (10
/ 30 / 100mA)
0 ~ 300ms (10 / 30
/ 100 / 300mA)
0 ~ 40ms (10 /
30 / 100mA)
X / X1 / X5 (10 / 30
/ 100 / 300 / 500mA)
X / X1 / X5 (10
/ 30 / 100mA)
Voltage Measurement
0Vac ~ 600Vac
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
24
0.00M ~ 250M
(5% rdg + 5 LSD)
@ 250V
0.00M ~ 500M
@ 500V
0.00M~1000M
@ 1000V
(Buzzer threshold: 2M)
X / X1 / X5 (10 / 30
/ 100 / 300 / 500mA)
50Vac or more
Operating Temperature
Product Weight
Storage Temperature
Regulation Compliance
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
Included Accessories
Included Accessories
KMP7030
Specifications (At 23C 5C, 45% to 75% RH)
Operating Voltage
230Vac, 50 Hz
+10% to -15%
Trip current @ X
Trip current @ X1
10/20/30/100/300mA
(trip time 0 to 1000ms)
500mA (trip time
0 to 300ms)
Trip current @ X5
10/20/30mA (trip
time 0 to 40ms)
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
Included Accessories
KMP7010
230Vac, 45Hz ~ 65 Hz
+10% to -15%
Loop Impedance 20
/ 200 / 2000
0 ~ 19.99 / 199.9
/ 1999
AC Test Current
25A Nominal at 20
AC Test Period
10ms at 20
0 ~ 19.99 / 199.9 (L
(3% rdg + 6 LSD)
N impedance > 20 )
0.0 ~ 199.9 /
1999 / 19.9kA
Voltage Measurement
100Vac ~ 300Vac
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
Included Accessories
KMP7036
0.00 ~ 40.00
0.0 ~ 400.0
0 ~ 4000
Voltage Measurement
0Vac ~ 400Vac
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
Included Accessories
Operating Voltage
Technical Specification
Insulation Resistance @
250V/500/1000V (Test
Current 1mA)
0.00M ~ 4.99M
5.0M ~ 49.9M
50M ~ 999M
1.00G ~ 1.99G
(Buzzer threshold: 4M)
Continuity @ IN 200mA,
Uo=5Vdc (Nominal)
0.00M ~ 9.99 M
10.0M ~ 99.9 M
AC Voltage Measurement
30Vac ~ 750Vac
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
Included Accessories
25
Technical Specification
Clamp-on Meters
Clamp Multimeter Comparison Guide
Measurement Ranges
Display
Current AC
Tolerance
Frequency Range
Current DC
Tolerance
Voltage AC
Tolerance
Frequency Range
Voltage DC
Tolerance
Continuity
Frequency
Resistance
Tolerance
Capacity
Active Power
Cos Phi
Harmonics
Jaw Opening
Pollution Degree
Features
Overvoltage Category
Safety
Power Supply
Dimensions
Weight
ACD-14 Plus
ACDC-400
ACD-20SW
LCD, 33/4-digit,
LCD, 3 Digit,
LCD, 3 Digit,
4000 digits
3999 Count
3999 Count
0.01 - 600 A
0.01 A - 400 A
0.01 - 400 A
(1.9% rdg. + 8 digits) (1.5% rdg. +3 Digits) (2% rdg +6 Digits)
50/60 Hz
50/60 Hz
50-60 Hz
0.01 A - 400 A
(1.5% rdg. +3 Digits)
0.001 - 600 V
0.1 mV - 600 V
1.0 mV-600,0 V
(1.5% rdg. + 5 digits) (1% rdg. +3 Digits) (1.2% rdg +5 Digits)
50 - 400 Hz
50 - 500 Hz
50 - 500 Hz
0.1 - 600 V
0.1 mV - 600 V
0.1 mV - 600 V
(0.5% rdg. + 3 digits) (0.8% rdg. +2 Digits) (0.5% rdg +2 Digits)
R < 120
R < 40
R < 25
0.001 Hz - 100 kHz
0.1 - 40.00 M
0.1 - 40 M
0.1 - 40 M
(0.8% rdg. + 6 digits) (1% rdg. +3 Digits) (1.0% rdg +4 Digits)
0.1 nF - 3000 F
26 mm
2
30 mm
2
CAT III/600 V
EN 61010/IEC 61010
2 x 3 V battery,
IEC CR2032
190 x 63 x 32 mm
approx. 200 g
30 mm
2
CAT III/600 V
CAT lll/600 V
Measurement Ranges
Display
Current AC
Tolerance
Frequency Range
Current DC
Tolerance
Voltage AC
Tolerance
Frequency Range
Voltage DC
Tolerance
Continuity
Frequency
Resistance
Tolerance
Capacity
Active Power
Cos Phi
Harmonics
Temperature
Input Impedance
Jaw Opening
Pollution Degree
Features
Overvoltage Category
26
Safety
Power Supply
Dimensions
Weight
ACDC-54NAV
LH41
AC50A
LCD, 3 Digit,
LCD, 3 Digit,
LCD, 3 Digit,
4000 Count
4000 Count
3999 Count
0.01-1000 A
0.001 - 40 A
0.01 mA - 60 A
(1.5 % rdg. +5 Digits) (1.3 % rdg. +5 Digits) (1.5% rdg. +5 Digits)
50 Hz - 400 Hz
40 - 400 Hz
40 Hz - 1 kHz
0,001 - 40 A
(1.3 % rdg. +5 Digits)
0,01 - 1000 V
0,1 - 400 V
(1 % rdg. +5 Digits)
(2% rdg. + 4 Digits)
50 - 500 Hz
40 Hz - 1 kHz
0.01 - 1000 V
(0.7% rdg. +2 Digits)
R < 30
R < 40
20.00 - 9.999 kHz
0.199.99 k
0.1 - 400
(1% rdg. +5 Digits)
(1% rdg. +2 Digits)
0 - 999.9 kW
-1.000.00 +1.00
display up to the 25th
-50 C-1000 C
10 M
37 mm
2
CAT IV 600V,
CAT III 1000V
DIN VDE 0411,
EN 61010/IEC 61010
1 x battery 9 V,
IEC 6F22
260 x 80 x 40 mm
approx. 480 g
19 mm
2
30 mm
2
CAT III/600 V
CAT III/600 V
ACDC-100
ACD-50NAV
LCD, 3 Digit,
LCD, 3 Digit,
4000 Count
4000 Count
0.1 A - 800 A
0.01 - 600 A
(1.5% rdg. +5 Digits) (1.5 % rdg. +5 Digits)
50 Hz - 400 Hz
0.1 A - 1000 A
(1.5% rdg. +4 Digits)
0.1 mV - 600 V
0.01 - 1000 V
(1% rdg. +4 Digits) (1 % rdg. +5 Digits)
50 - 500 Hz
50 Hz - 500 Hz
0.1 mV - 600 V
0.01 - 1000 V
(0.5% rdg. +3 Digits) (0.7 % rdg. +2 Digits)
R < 120
R < 30
20,00 - 9,999 kHz
0.1 - 40.00 M
0.199.99 k
(0.8% rdg. +6 Digits)
0 - 600.0 kW
-1.000.00 +1.00
display up to the 25th
50 mm
2
37 mm
2
CAT IV 600V,
CAT III/600 V
CAT III 1000V
DIN VDE 0411,
DIN VDE 0411,
EN 61010, IEC 61010 EN 61010, IEC 61010
2 x Battery 1.5 V,
1 x Battery 9 V,
IEC LR03
IEC 6F22
227 x 78 x 40 mm
260 x 80 x 40 mm
approx. 290 g
approx. 480 g
Digital Multimeters
AM-500-EUR
Events
Display
Features
Functions
MULTIMETER TYPE
Safety Rating
Safety
True-rms
AC Voltage (V)
DC Voltage (V)
AC Current (A)
DC Current (A)
Resistance (MOhms)
Microamps
Diode Test
Continuity
Battery test
Capacitance
Frequency
Non-contact voltage
Duty cycle
Temperature inputs
Autoranging
Manual ranging
Low pass filter
Low Z
Built-in flashlight
Meter resolution
Dimly lit areas
Monitoring fast changing signals
Two relative measurements on one screen
LCD Counts
Backlight
Bar graph
Dual display
Data memory
Difference between two measurements
Max/min peak measurement
Specialised signal measurements
Data hold
Relative reading
Max/min hold
Peak hold (crest)
AM-510-EUR
AM-520-EUR
AM-530-EUR
AM-540-EUR
AM-550-EUR
Autoranging
Com / Res
HVAC
Electrical
Adv. HVAC
Industrial
CAT IV 600
CAT III 1000
CAT IV 600
CAT III 1000
600
600
10
10
20
600
600
10
10
40
750
1000
10
10
40
750
1000
10
10
40
1000
1000
10
10
60
1000
1000
10
10
60
1
n
n
n
2,000
4,000
4,000
4,000
6,000
6,000
Technical Specification
Specifications GT-400-UK
Protective conductor resistance
Insulation resistance
Substitute leakage current
Supplied with
Insulation Resistance
Measuring range
Display range
Resolution
Tolerance
Measuring current / voltage
0.1 ... 20 M
0.1 ... 20 M
0.1 ... 9.999 M 0.001 M / 10.00 ... 20.00 M 0.01 M
(5% + 2 digits)
Min. 500 V DC / >1 mA
0.1 ... 20 mA
0.1 ... 20 mA
0.1 ... 9.999 mA 0.001 mA / 10.0 ... 20.00 mA 0.01 mA
(5% + 2 digits)
Approximately 32 V AC
General Specifications
Power supply
Degree of pollution
Overvoltage category
Protection degree
Protection class
Electrical safety
EMC emission
EMC interference resistance
Dimensions (L x W x H)
Weight
27
Subject to change