DESIGN FOR BASE PLATE (PINNED)

Design Data
Assumed section
Depth of section
Width of section
Thickness of flange
Maximum vertical load
Minimum vertical load
Resultant horizontal shear
Length of plate
Width of plate
Assumed thickness of weld
plate & column connection
Design strength of fillet weld
Design strength of the plate
Grade of concrete
Diameter of bolts
Grade of bolt
Number of bolts
Tensile area of bolt
Shear strength of bolt
Tensile strength of bolt
L=

Case ( i )
Case ( ii )

for base

=
=
=
=
=
=

T
F1
F2
Fs
L
B

= UC 203 x 203 x 46
=
203.2
=
203.6
=
11.0
=
150
=
-18
=
36
=
250
=
250

6.0

mm

=
=
=
=

pw
pyp
fcu
db

=
=
=

220.0
265
35
20
4.6
2
245
160
240

N/mm2
N/mm2
N/mm2
mm

N
At
ps
pt

=
=
=
=
=
=
=
=
=

mm
mm
mm
kN
kN
kN
mm
mm

(Page No.-----)
(Page No.------)
(Page No.-----)

mm2
N/mm2
N/mm2

Table 30

250

B = 250
20mm thk plate
2 - 20dia bolts
Bearing pressure
Case ( i ) Loading
Base pressure
Permissible bearing pressure

Case ( ii ) Loading
Base pressure
Permissible bearing pressure

=
=

=
=

w
wp

w
wp

=
=
=
>
=
=
=
>

>
2.40
N/mm <
0.6 fcu
OKAY
2
21.0
N/mm NOT OKAY
Actual base pressure
>
2
0.00
N/mm <
0.6 fcu
OKAY
2
21.0
N/mm NOT OKAY
Actual base pressure
2

OKAY

OKAY

Bolt capacity under tension


Force in bolt due to direct tension
Tensile capacity of single bolt

Ft
= Pnom

=
=
=

F2 / N
9.0
0.8 pt At

47.0
> Actual force on bolt
Check for horizontal shear
Shear capacity of one bolt

Ps
Fs

Actual horizontal shear / bolt


Safety index
Check for combined shear and tension
Fs
Ft
+
<
Ps
Pnom
Check for thickness of base plate
Maximum base pressure
Largest perpendicular distance from
the edge of eff portion to face of column
Minimum thickness of the plate

1.4

OKAY

ps As
39.2
Fs / N

kN OKAY
kN NOT OKAY

18.0
2.2

0.65

<

1.4

1
>
<
OKAY
NOT OKAY

2.40

N/mm2

=
=

c
t

=
23.4
0.5
c(3w/p
)
=
yp
=
3.86
=
20

mm
mm
mm
mm

F2

Check for edge distance


Minimum edge distance
Minimum edge distance required as per
=
Non-ductile design (in inch)

=
=
=
=
=
=
=
>

kN
mm
kN/mm
kN/mm >
kN/mm <
OKAY
0.92
kN/mm NOT OKAY
Resultant weld shear

4.13.2.2
OKAY

18.0
1176.8
0.02
0.03
0.03
0.7 s pw

= max. of 4d & 115 mm


=
115
mm
m

OKAY

OKAY

Thickness provided
Column / base plate weld
Maximum tension
Length of weld available
Weld shear (Tension)
Weld shear (Horizontal force)
Resultant weld shear
Weld capacity

=
=
=
=
=

>
kN <
OKAY
kN NOT OKAY

= D * SQRT{fut / [73*SQRT(f'c)]}

OKAY

=
=

69.6
120

Edge distance provided


Check for anchorage length under tension
Anchorage required as per BS 8110 recommendations.
Design ultimate anchorage bond stress
= fbu
= (fcu)1/2
=
0.28

= fbu
=
1.66
Ft/fbudb
= La
=
=
86.5
Anchorage required as per "Sabic Engineering" recommendations.
Minimum required anchorage
= 12 * bolt dia.
=
240
Minimum embedment required as per
= La = SQRT(a2+b2)
Non-ductile design
170
Lap =
Anchorage length provided as per Sabic
460
Engineering standard B50-F01-13

mm
mm

N/mm

OKAY

BS8110,
Table 3.26

>
mm OKAY

mm

mm
mm

OKAY