K-LINE INSULATORS LIMITED

50 Passmore Avenue, Toronto, Ontario M1V 4T1


Tel: (416) 292-2008 - Fax: (416) 292-2094
E-Mail insulators@k-line.net
Web Page: www.k-line.net

Dear Sir/Madam,
I'm pleased to introduce you to our complete line of polymer insulated products. The attached
K-LINE INSULATORS catalogue includes the products we are currently offering to the utility
industry.
Other products are under development and will be available shortly. As these products come on
the market, we will issue you the pertinent information. In the meantime, if you require an
insulator configuration not shown in the catalogue, give us a call.
In order to register this catalogue to you, so that we can provide you with updates, please
complete the attached request card and return it to us. If you are passing this catalogue onto one
of your staff, please have them complete the card and return it. If you require an additional
catalogue for someone else in your organization, please have them complete the attached form
(noting "ADDITIONAL CATALOGUE REQUIRED" on the card) and return it to U.S.
We look forward to fulfilling your polymer insulator needs. Should you have any questions or
need further information, feet free to call me at (416) 292-2008.

Sincerely,

K-LINE INSULATORS LIMITED

A.J. (Tony) Carreira, P.Eng.


President
Encl.

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada, M1V 4T1
Tel; (416) 292-2008 Fax: (416) 292-2094
E-Mail; insulators@k-line.net Web Page: www.k-line.net

K-LINE INSULATORS PROFILE

K-LINE INSULATORS is a quality silicone insulator manufacturer.


The company was established in 1983 with its head office located in Toronto, Ontario,
Canada. K-LINE INSULATORS products are distributed world-wide through a
consolidated network of representatives.
Product lines manufactured by K-LINE INSULATORS include transmission and
distribution suspension, line post and station post insulators, featuring our patented
Universal Line Post design. Other products include riser support insulators, dead-end
extension insulators, polymer-coated guy strains, and specialty insulators for in-line
switches, air-break switches, interphase spacers, railways and live line tools. These
insulators are designed to the various standards (i.e. CSA, CEA, ANSI, IEEE, IEC, etc.).
K-LINE INSULATORS introduced a patented Universal Polymeric Line Post End Fitting
design. The end fitting is referred to as the "K" clamp. Finally, there is one line post
insulator that can be installed in either a horizontal or vertical configuration, with the
clamp integrated into the insulator design. Some of the immediate benefits of the "K"
clamp are that it is made of corrosion resistant aluminum casting, has the capability to
accommodate a full range of conductor sizes, contains only a single captive live-line
operable bolt, and no loose parts. Purchasers of the "K" clamp have been able to take
advantage of labour cost savings in stringing, sagging, and conductor clamping, along
with other savings related to shipping, stocking, and maintenance. The "K" clamp has
performed excellently in the field since 1992.
K-LINE INSULATORS has excellent engineering resources and test facilities for product
development. K-LINE INSULATORS uses its own proprietary technologies, designs and
rubber formulations, in the manufacture of all its insulator products.
K-LINE INSULATORS' highly developed proprietary silicone rubber formulation is
characterized by its superior contamination performance. All insulators are injection
molded, one piece, and exhibit self-cleaning characteristics. The rubber is bonded to the
fibreglass core strength member. These products have a long and proven performance
record in severely contaminated environments.
Continued on next page >

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada, M1V 4T1
Tel; (416) 292-2008 Fax: (416) 292-2094
E-Mail; insulators@k-line.net Web Page: www.k-line.net

K-LINE INSULATORS PROFILE (Continued)

K-LINE INSULATORS manufactures all of its products and is registered to the rigid
Quality Assurance Standards of the ISO9001 program. The company is audited on a
continuous basis by its customers and an internationally recognized quality management
auditing firm.
K-LINE INSULATORS is known for its readiness to listen to its customers' needs for
customized polymeric insulator designs that meet their special requirements. We offer
appropriate support in the proper selection of insulators to suit the application, with
training and documentation on special installation requirements. K-LINE INSULATORS
is committed to a continuous improvement policy in quality, service, delivery, and cost
reduction. Much pride comes from the innovation of new products and the continuous
improvements of present products to ensure that the insulators are the most cost effective
and have a long term system performance.
K-LINE INSULATORS approach to innovative insulator solutions is well demonstrated
and respected by its customers.
K-LINE INSULATORS people are totally dedicated to continuous quality and
performance improvement. They are dedicated to developing the best materials and
designs that lead to optimum product solutions. These characteristics amongst others,
have contributed to the success of the various strategic alliances K-LINE INSULATORS
has forged with some of its customers.
K-LINE INSULATORS is sensitive and committed to the needs of its customers and is
always prepared to give them the service they expect and deserve.

Catalogue Numbering of Distribution Class Insulators


Catalogue Number
Insulator
Type

Suspension/
Deadend

KL

Company
ID

Voltage Class

Material

Insulator
Type

X
End Fittings *

K-Line

15
28
35
46
69

Shed Design

A - Alternating
sheds
No A Other shed
design

Structure End
Fitting

C- Clevis
S Socket
T - Tongue

S - Silicone
rubber

Line End
Fitting

T - Tongue
H - Thimble
B Ball
E Oval eye
Y Y clevis

N/A

Line Post

N/A

N/A

K - K-clamp
V - Vertical
H - Horizontal
T - Tie-Top C
Neck
TF - Tie-Top F
Neck
E Drop Eye

Special
Variations

R - 90 deg turn on
end fittings
M - Medium SML
70 kN
A - LA insulator
F Steel Fittings
N - Non-standard

A Lock washer
Al Alum base
D - Tinned alum
line fitting
E Eye Nut
G - Gain base
M20 - 20 mm
tapped
M22 - 22 mm
tapped
M24 - 24 mm
tapped
N - Non-standard

Catalogue Number of Distribution Class Insulators

Station Post

CP - Cap &
Pin
P - Post

T1 - Tapped one end


T2 - Tapped both ends
No Ts - Thru holes both ends

Railway

N/A

RW Railway

C- Clevis
S Socket
T Tongue
B Ball

Riser

A - Alternating
sheds
No A Other shed
design

Guy

Insulated
length in
inches

N/A

RSI Riser
support
insulator

N/A

Note:
* Different fittings will be designated by the addition of a number to the letter.

Sebastian Marra
K-Line Insulators Limited
February 19, 2002

N/A

N/A

C- Clevis
H - Thimble
T Tongue
R Roller
B - Threaded

M12 - 12 mm
tapped
M16 - 16 mm
tapped
M20 - 20 mm
tapped

C- Clevis
S Socket
T Tongue
B Ball

U - Clamp

D - Tin plated
aluminum line
fitting
X 5/8 tapped
base

T - Tongue
H - Thimble
C- Clevis
R Roller
B - Threaded

R - 90 deg turn on
end fittings
S - Silicone

Catalogue Numbering of Transmission Class Insulators


Catalogue Number
Insulat
or
Type

KL
Compan
y ID

X
Voltage
Class

Suspensi
on/Deade
nd

X
Shed
Design

H High
leakage

Insulator
Material
Type

N/A
N/A

Line Post
K-Line

69
115
138
161
230

Station
Post

Sebastian Marra, September 18, 2000

SSilicone
rubber

End Fittings
Line End
Fitting

Structure
End Fitting
S Socket
B - Ball
C- Clevis
T - Tongue
T - Tongue
H - Thimble
Y Y Clevis
E - Eye
E - Eye
E - Eye
V - Vertical
HHorizontal

AAlterna
ting
sheds

G Gain
base
BF Flat

No. of
Sheds

Corona
Ring

Other
Additions

M
Medium
ring
N No ring

Al
Aluminum
base

#
N/A

P - Post

T1 - Tapped one end


T2 - Tapped both ends
No Ts - Thru holes both
ends

A - IEC
B IEC20
R 90 Deg
S SS pin

M12 - 12 mm
tapped
M16 - 16 mm
tapped
M20 - 20 mm
tapped
N - Nonstandard

K-LINE INSULATORS LIMITED

Catalogue D-DS

TORONTO, ONTARIO, CANADA

DISTRIBUTION SILICONE INSULATORS


Deadend / Suspension
15 kV to 46 kV

Distribution Silicone Insulators


Deadend / Suspension
In general Overhead Distribution Lines tend to experience a large number of outages and interruptions due to
insulation failures. These failures may be from surface contamination or wetting on line insulators that results in
flashovers or pole fires.
Silicone suspension/dead-end insulators offer the ultimate solution in improved performance. Because of its
hydrophobicity, this material inherently resists water filming thereby limiting leakage currents. Insulators with
reduced leakage currents, even when contaminated, require less frequent washing. The savings in such
maintenance costs are added benefits of using silicone insulators.
KLine silicone polymer distribution suspension/deadend insulators are manufactured and tested to world-class
polymer insulator standards; CEA LWIWG-01, ANSI C29.13, and IEC 1109. K-Line Insulators Limited is
registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators distribution suspension/dead-end insulators are listed below.

Improves Reliability (by minimizes interruptions and outages due to vandalism, pole fires, and flashovers in
all types of environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Distribution suspension/dead-end insulators are used on overhead lines operating at or below 46 kV. These
insulators are used to support line conductors in suspension or dead-end modes such as line terminations, angles,
and tangents. These insulators can be used with bare or covered conductors.

Core Material
The core rod of the distribution suspension/dead-end insulator is made of a high quality fiberglass that has been
specially formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected molded silicone rubber that is chemically bonded to
the core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

Distribution Deadend/Suspension Insulator

TECHNICAL DATA
SPECIFICATIONS

UNIT

Voltage Class
CEA & ANSI Class
Section Length L
Dry Arcing Distance
Leakage Distance

kV
mm (in)
mm (in)
mm (in)
kV
kV
kV
kV
V
kN (lb)
Nm (ftlb)
kg (lb)

Dry
Wet
Impulse Critical Flashover (Positive)
Test
Radio Influence Voltage
(RIV) at 1 MHz
Max.
Specified Mechanical Load (SML)
Torsional Load
Approx. Weight
Low-Frequency Flashover

KL15ASCTM
15
DS15
322 (12.7)
193 (7.6)
384 (15.1)
100
70
145
15
Below 1
70 (15,700)
83 (62)
0.7 (1.5)

CATALOGUE NUMBER*
KL28ASCTM
KL46SCTN
KL46SCT
28
35/46
46
DS28
DS46
433 (17.0)
548 (21.6)
574 (22.6)
290 (11.4)
386 (15.2)
419 (16.5)
590 (23.2)
850 (33.5)
988 (38.9)
135
155
180
105
135
150
225
285
300
20
30
30
Below 1
Below 5
Below 5
70 (15,700)
90 (20,200) 90 (20,200)
83 (62)
83 (62)
83 (62)
0.8 (1.8)
1.3 (2.8)
1.6 (3.5)

KL46SCTA
46
646 (25.4)
490 (19.3)
1059 (41.7)
200
155
355
30
Below 5
90 (20,200)
83 (62)
2.2 (4.8)

* The catalogue numbers in the above table are for CT clevis-tongue fittings. For other combinations of end
fittings, see End Fittings Section.

End Fittings
There are three standard end fittings that are available on the suspension/dead-end insulators: clevis, tongue,
and thimble eye (See Below). All end fittings are made from high strength, corrosion resistant extruded
aluminum. The end fittings are crimped on to the core rod to provide the mechanical performance. A
watertight seal between the rubber and end fittings eliminate possible moisture ingress. This special silicone
rubber to metal fittings sealing process provides total exclusion of moisture.
The end fittings of the distribution class suspension/dead-end are rated for a specified mechanical strength,
SML of 70 kN (15,700 lb) or 90 kN (20,200 lb).
The clevis and tongue end fittings are the two most common fittings used with additional adaptors and
clamps. The thimble eye end fitting is a unique design that integrates the insulator tongue end fitting and a
conductor performed grip adapter to attach to the line conductor. This thimble eye essentially eliminates one
item in the assembly and from inventory.
For other special end fittings please contact K-Line Insulators.
Clevis - C

Tongue - T

Thimble Eye - H

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
Tel.: (416) 292-2008 Fax: (416) 292-2094 E-Mail: insulators@k-line.net Web Page: www.k-line.net

K-LINE INSULATORS LIMITED

Catalogue D-LP

TORONTO, ONTARIO, CANADA

DISTRIBUTION SILICONE INSULATORS


Line Post

15 kV to 69 kV

Distribution Silicone Insulators


Line Post
Insulator contamination is a common problem on overhead lines. The fundamental element for interruptions with
contaminated insulators is moisture. Wet atmospheric conditions result in water filming on surfaces and causing
leakage currents to develop. On wood structures, leakage currents can cause pole top fires. On steel structures,
leakage currents can develop into faults.
Silicone offers the ultimate solution in line post insulators. Because of its hydrophobicity, this material inherently
resists water filming thereby limiting leakage currents. Silicone insulators reduce leakage currents, even when
contaminated and require less frequent washing. The savings in such maintenance costs are added benefits of using
silicone insulators.
KLine silicone polymer distribution line post insulators are manufactured and tested to world-class polymer
insulator standards, CEA LWIWG-02. K-Line Insulators Limited is registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators distribution line post insulators are listed below.

Improves Reliability (by minimizing interruptions and outages due to vandalism, pole fires, and
flashovers in all types of environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing
plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Distribution line post insulators are used on overhead distribution lines operating at and below 69 kV. These
insulators are commonly installed on metal or wooden structures to horizontally or vertically support the line
conductor. Also, these insulators are used to support high voltage conductor jumpers or leads.
.

Rod
The core rod of the insulator is made of a high quality fiberglass that has been specially formulated for electrical
and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injection molded silicone rubber that chemically bonds to
the core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

LINE POST INSULATORS

K-clamp**

H-Horizontal

V-Vertical

T-TieTop (C-neck)
TF-TieTop (F-neck)

TECHNICAL DATA
SPECIFICATION

UNIT

Voltage Class
CEA Class
Section Length (L)***
Dry Arcing Distance
Leakage Distance
Critical Impulse Flashover
Low-Frequency Flashover
Radio Influence Voltage
(RIV) at 1000 kHz

kV
mm (in)
mm (in)
mm (in)
Positive
Negative
Dry
Wet
Test
Max

Specified Tensile Load (STL)


Specified Cantilever Load (SCL)
Max Design Cantilever Load (MDCL)
Number of Sheds
Approx. Weight

kV
kV
kV
V
kN (lb)
kN (lb)
kN (lb)
No.
kg (lb)

KL15S
15
LP15
287 (11.3)
145 (5.7)
275 (10.8)
130
155
75
40
10
2.5
22 (5000)
12.5 (2800)
6 (1350)
2
3.4 (7.4)

CATALOGUE NUMBER*
KL28S
KL35S
KL46S
28
339 (13.3)
190 (7.5)
420 (16.5)
160
205
95
65
15
2.5
22 (5000)
12.5 (2800)
6 (1350)
3
3.7 (8.0)

35
LP28M
415 (16.3)
270 (10.6)
660 (26.0)
195
285
120
85
22
2.5
22 (5000)
12.5 (2800)
6 (1350)
5
4.3 (9.4)

46
LP46
491 (19.3)
345 (13.6)
864 (34.0)
240
350
145
115
30
2.5
22 (5000)
12.5 (2800)
6 (1350)
6
4.7 (10.3)

KL69S
69
LP46M
614 (24.2)
483 (19.0)
1117 (44.0)
310
200
160
30
2.5
22 (5000)
12.5 (2800)
6 (1350)
10
9.1 (20.0)

Ordering Information
To catalogue number, add suffix H for horizontal, V for vertical, T for C-neck Tie-top, TF for the F-neck Tie-top, or K for
K-clamp. Standard base threads are -10 UNC. Different base threads are available upon request.

** K-clamp conductor diameter range 7.6 mm (0.30) to 34.0 mm (1.34).


*** Section lengths are for tie-top insulators. For others refer to Section Length Adjustment Table under End Fittings.

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
Tel.: (416) 292-2008 Fax: (416) 292-2094 E-Mail: insulators@k-line.net Web Page: www.k-line.net

Fittings
Line End Fitting
The line end fitting of line post insulators are available in four different configurations: horizontal or vertical
clamp-top, tie-top, or K-clamp.
All line end fittings on line post insulators are made of corrosion resistant aluminum alloy castings.
SECTION LENGTH ADJUSTMENT
Line End Fitting

Line End Fitting Designation

Section Length

Tie-Top
Horizontal
Vertical
K-Clamp

T
H
V
K

See Technical Data sheet


L + 51 mm (2.0)
L + 38 mm (1.5)
L + 8 mm (0.3)

Clamp-Top
The conventional horizontal and vertical trunnion accommodates a standard line post insulator, bolted conductor
clamp. On the horizontal design the line end fitting has an additional eye for the attachment of other devices
during installation or maintenance activities.
Tie-Top
The tie-top is designed for tying a conductor to the neck of the insulator. It is available in two standard neck
sizes: C or F-neck.
K-Clamp
K-Line Insulators Limited has introduced a new concept in the polymer line post live end fitting design. This end
fitting is referred to as the K clamp. The uniqueness of this end fitting is a result of the many advantages its
has over the traditional horizontal, vertical and tie-top configurations.
Some advantages of the K clamp include:
1) Excellent corrosion resistant aluminum casting
2) A long, smooth contoured conductor clamping zone
3) The clamp accommodates a full range of conductor sizes
4) A single captive live-line operable bolt
5) All parts are captive
6) Lower overall length permits standard cover up hoods to effectively cover all insulator sheds
7) The design can be installed in either a horizontal or vertical configuration
8) Inventory reduction is accomplished because one insulator is used for both configurations and a
separate clamp is not required
9) The price of the new insulator is cost comparative with the purchase of a standard trunnion post
insulator and a separate clamp
10) Substantial labour cost savings in stringing, sagging and conductor clamping
11) Other savings related to shipping, stocking and maintenance

Base End Fitting


The standard base for line post insulators is a round flat iron base with a threaded hole that accommodates a
standard insulator stud or bolt. For other special bases contact K-Line Insulators Limited.
Hot-dip galvanizing to CSA G164 and ASTM A153 specifications provides corrosion protection of the base end
fitting.

K-LINE INSULATORS LIMITED


TORONTO, ONTARIO, CANADA

Catalogue D-SP

DISTRIBUTION SILICONE INSULATORS


Station Post
15 kV to 46 kV

Distribution Silicone Insulators


Station Post
One of the most critical assets of an electrical Distribution System is the station. Not only is this asset the heart of
the supply to large electrical loads but it also serves many customers from industrial to residential. Therefore,
outages or interruptions due to insulation failures are costly and impact negatively on customer service. With KLine silicone station insulators these are greatly minimized through improved performance to reliability and
savings in the life cycle cost.
Silicones hydrophobic property allows K-Line station insulators to electrically outperform porcelain insulators.
The lightweight feature of polymer insulators makes it easy to handle and install. The size and fittings of polymer
station insulators ensure that they are compatible with existing station post hardware and arrangements.
Experience with silicone polymer insulators has proven their superiority over porcelain insulators.
KLine silicone polymer distribution station post insulators are manufactured and tested to world-class polymer
insulator standards, CSA and ANSI. K-Lines Quality System is registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators distribution station post insulators are listed below.

Improved Reliability (interruptions and outages due to vandalism, and flashovers in all types of
environments are a thing of the past)

Eliminate or Reduce Maintenance (such as washing and trouble calls) and is compatible with existing
porcelain insulators
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation, eliminates catastrophic mechanical failures)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Distribution station post insulators are used in open-type stations operating at and below 46 kV. These insulators
support the bus, leads, or other apparatus within the station.

Rod
The core rod of the distribution station post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected molded silicone rubber that chemically bonds to the
core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

Distribution Station Post Insulator

TECHNICAL DATA
SPECIFICATION

UNIT

KL15SCP

KL25SC

CATALOGUE NUMBER*
KL25SP
KL25SPN

KL35SP

KL46SP

Voltage Class

kV

15

25

28

28

35

46

ANSI Technical Reference (TR)

No.

4 & 205

208

10

210

214

mm (in)

254 (10)

305 (12)

355 (14)

415 (15)

491 (18)

614 (22)

Section Length (L)


Dry Arcing Distance

mm (in)

145 (5.7)

190 (7.5)

260 (10.2)

270 (10.6)

345 (13.6)

483 (19.0)

Leakage Distance

mm (in)

275 (10.8)

420 (16.5)

635 (25)

660 (26.0)

864 (34.0)

1117 (44)

Impulse Withstand

kV

125

155

165

180

225

275

Critical Positive Impulse Flashover

kV

130

160

175

195

240

310

Low-Frequency Wet Withstand


Radio Influence Voltage
(RIV) at 1000 kHz

kV

40

95

65

120

145

200

Test

kV

10

15

22

22

30

30

Max

2.5
45
(10000)
12.5
(2800)
6 (1350)

2.5
45
(10000)
12.5
(2800)
6 (1350)

2.5
45
(10000)
12.5
(2800)
6 (1350)

2.5
45
(10000)
12.5
(2800)
6 (1350)

2.5
45
(10000)
12.5
(2800)
6 (1350)

Specified Tensile Load (STL)

kN (lb)

Specified Cantilever Load (SCL)

kN (lb)

Max Design Cantilever Load (MDCL)

kN (lb)

2.5
45
(10000)
12.5
(2800)
6 (1350)

No.

10

kg (lb)

3.4 (7.4)

3.7 (8.0)

4.2 (9.2)

4.3 (9.4)

4.7 (10.3)

9.1 (20.0)

Number of Sheds
Approx. Weight

* Ordering Information:
1.
2.

Above catalogue numbers apply to insulators with through holes on both ends.
Add T1 to catalogue numbers for insulators with one end tapped & the other with through holes.

3. Add T2 to catalogue number for insulators with both ends tapped.

End Bases
The standard base fittings are flat round iron bases that are available with bolt circle mounting holes with
either through or tapped holes. These bases are compatible with the porcelain station post insulator
standard.
The end bases are radialy swaged on to the core rod to provide the mechanical performance and reduce
the stress concentration. Our proprietary design insures a watertight seal between the rubber and end
fitting. This special silicone rubber to metal fittings sealing process prevents moisture ingress to the core
fiberglass rod. For other special base requirements, please contact K-Line Insulators Limited.
Corrosion protection of the end bases is provided by hot-dip galvanizing to CSA G164 and ASTM A153
specifications.

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
Tel.: (416) 292-2008 Fax: (416) 292-2094 E-Mail: insulators@k-line.net Web Page: www.k-line.net

K-LINE INSULATORS LIMITED

Catalogue T-DS

TORONTO, ONTARIO, CANADA

TRANSMISSION SILICONE INSULATORS


Deadend / Suspension
69 kV to 230 kV

Transmission Silicone Insulators


Deadend / Suspension
One of the most important item on any transmission overhead line is the insulator. This item is the backbone of
the transmission system in minimizing interruptions and outages, and providing for a safe plant. Therefore, it is
essential to have high quality and dependable insulators on the system. With KLine silicone polymer
transmission insulators these objectives can be easily achieved with a substantial savings in the life cycle cost.
Experience with silicone polymer insulators has proven their superiority over porcelain insulators. Today more
Electric Utilities are shifting to silicone polymer insulators to improve overall performance on transmission
overhead lines.
KLine silicone polymer transmission suspension/deadend insulators are manufactured and tested to world-class
polymer insulator standards, CSA C411.4, ANSI C29.11 and IEC 1109. K-Line Insulators Limited is registered to
ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators transmission suspension/deadend insulators are listed below.

Improved Reliability (interruptions and outages due to vandalism, pole fires, and flashovers in all types of
environments are a thing of the past)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Transmission suspension/deadend insulators are used on transmission lines operating at and above 66kV. These
insulators are installed on metal or wooden structures on cross arms to hold the conductor longitudinally (dead-end) or
vertically (suspension). The connections to the structures or arms and line vary depending on the Utilities preference.

Rod
The core rod of the transmission suspension/deadend insulator is made of a high quality fiberglass that has been
specially formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected-molded silicone rubber that chemically bonds to the
core rod. This ensures that the interface between the rubber and rod is impenetrable against moisture ingress.

Deadend / Suspension Insulator

TECHNICAL DATA
TECHNICAL DATA

Catalogue
Number

Voltage
Class
kV

KL69HBS13
KL69HBS16

69

KL69HBS19
KL115HBS22

Section
Length (Note 1)
L
mm

(in)

Dry Arcing
Distance
mm

(in)

Leakage
Distance
mm

(in)

Positive
Critical
Impulse
Flashover

Low
Frequency
Flashover

Weight
(Note 2)

kV

Dry
kV

Wet
kV

kg

(lb)

660 (26.0)

523 (20.6)

1466 (57.7)

355

215

170

2.9 (6.3)

764 (30.1)

627 (24.7)

1798 (70.8)

425

260

205

3.3 (7.2)

867 (34.1)

732 (28.8)

2131 (83.9)

485

300

235

3.6 (8.0)

970 (38.2)

818 (32.2)

2461 (96.9)

540

335

265

4.2 (9.2)

1074 (42.3)

917 (36.1)

2794 (110.0)

600

375

300

4.5 (10.0)

1179 (46.4)

1021 (40.2)

3127 (123.1)

660

415

335

5.0 (10.9)

1281 (50.4)

1128 (44.4)

3460 (136.2)

725

455

370

5.4 (11.8)

1384 (54.5)

1229 (48.4)

3792 (149.3)

785

495

400

5.8 (12.7)

KL138HBS37

1488 (58.6)

1331 (52.4)

4125 (162.4)

845

530

430

6.1 (13.1)

KL161HBS40

1590 (62.6)

1410 (55.5)

4458 (175.5)

895

560

460

7.5 (16.4)

1694 (66.7)

1514 (59.6)

4790 (188.6)

960

605

495

7.9 (17.3)

KL161HBS46

1798 (70.8)

1618 (63.7)

5123 (201.7)

1025

650

530

8.3 (18.2)

KL230HBS49

1903 (74.9)

1722 (67.8)

5456 (214.8)

1090

695

570

8.6 (19.0)

2004 (78.9)

1824 (71.8)

5789 (227.9)

1155

740

605

9.0 (19.9)

2108 (83.0)

1928 (75.9)

6121 (241.0)

1220

785

640

9.5

KL115HBS25

115

KL115HBS28
KL138HBS31
KL138HBS34

KL161HBS43

KL230HBS52
KL230HBS55

138

161

230

(20.8)

Notes:
1.
Section lengths are based on ball and socket hardware. For lengths of insulators with alternate end fittings combination see Section Lengths.
2.
Weight includes standard rings where applicable. See section on Corona Rings.

End Fittings
The end fittings on the transmission insulator are made of high strength, cast (forged) steel. The insulators have a
specified mechanical load (SML) rating of 120 kN (27,000 lbs.). Also, all insulators are proof tested to 60 kN
(13,500 lbs.) in tension.
The end fittings are radialy swaged on to the core rod to provide the mechanical performance and reduce the
stress concentration. Our proprietary design insures a watertight seal between the rubber and end fitting. This
special silicone rubber to metal fittings sealing process prevents moisture ingress to the core fiberglass rod.
Hot-dip galvanizing to CSA G164 and ASTM A153 Standard provides corrosion protection of the end fittings.
The cotter key is made from stainless steel.
The standard end fittings that are available are listed and detailed in the below. For other special end fittings
contact K-Line Insulator Limited.

End Fitting Combinations

Section Lengths
The section lengths (L) published on the Technical Data sheet are for the ball and socket end fittings. For alternate
combinations of end fittings, use the following table to establish section lengths.
Section Length Adjustment
End Fitting
ANSI Ball / Socket
ANSI Ball / Y-clevis
ANSI Ball / oval Eye
oval Eye / oval Eye
Clevis / Tongue

End Fitting
Designation
BS
BY
BE
EE
CT

Section Length
L (see Technical Data sheet)
L + 36 mm (1.4)
L + 41 mm (1.6)
L + 84 mm (3.3)
L + 21 mm (0.8)

K-LINE INSULATORS LIMITED

CATALOGUE T-LP

TORONTO, ONTARIO, CANADA

Transmission Silicone Insulators


Line Post
69 kV to 161 kV

Transmission Silicone Insulators


Line Post
Today transmission lines are required to be more aesthetically pleasing and are routed through narrow right-ofways or along roadways. Also, at the lower transmission voltages (e.g., 115 kV and 69 kV) these lines are routed
through urban areas and along roadways similar to distribution circuits to supply substations and larger customers.
In some situations these lines share the same route and poles with distribution circuits. With K-Line silicone line
post transmission insulators an aesthetic compact line design can be easily achieved with a substantial savings in
the life cycle cost.
KLine silicone polymer transmission line post insulators are manufactured and tested to world-class polymer
insulator standards, CSA and ANSI. K-Lines Quality System is registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators transmission line post insulators are listed below.

Improved Reliability (interruptions and outages due to vandalism, pole fires, and flashovers in all types of
environments are a thing of the past)
Eliminate or Reduce Maintenance (such as washing and less trouble calls) and is compatible with existing
plant
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Transmission line post insulators are used on overhead transmission lines operating at and above 66 kV. These
insulators are commonly installed either vertically or horizontally on metal or wooden structures to support the
conductor. Also, these insulators are used to support high voltage conductor jumpers or leads.

Rod
The core rod of the transmission line post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected molded silicone rubber that is chemically bonded to
the core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

Transmission Line Post Insulator

TECHNICAL DATA

Catalog
Number

Voltage
Class
KV

KL69ASH13
KL69ASH16

KL115ASH25
KL138ASH28
KL138ASH31
KL161ASH34
KL161ASH37

L
mm

(in)

Dry
Arcing
Distance

Leakage
Distance

mm

mm

775 (30.5) 617


69

KL69ASH19
KL115ASH22

Section
Length
(See Note)

115

138

161

(in)

(in)

(24.3)

1544 (60.8)

Positive
Critical
Impulse
Flashover

Low
Frequency
Flashover

kV

Dry
kV

Wet
kV

380

250

225

Ultimate
Cantilever
Load
kN

(lbs)

29.4 (6600)

899 (35.4) 742

(29.2)

1890 (74.4)

450

295

260

26.1 (5870)

1022 (40.3) 866

(34.1) 2238 (88.1)

520

340

295

22.9 (5140)

1147 (45.2) 991

(39.0) 2583 (101.7)

595

385

330

19.6 (4410)

1271 (50.0) 1115 (43.9) 2931 (115.4)

665

430

365

16.5 (3700)

1395 (54.9) 1237 (48.7) 3277 (129.0)

735

475

410

14.9 (3340)

1519 (59.8) 1361 (53.6) 3622 (142.6)

805

520

450

13.3 (2980)

1643 (64.7) 1486 (58.5) 3970 (156.3)

880

560

475

11.7 (2630)

1767 (69.9) 1610 (63.4) 4318 (170.0)

955

600

495

10.1 (2275)

Note: Section length based on a horizontal trunnion and without any support base. For alternate bases and
line fittings (as well as overall lengths and weights of these) refer to the section on fittings and weights.

Transmission Line Post Insulator


K-Line transmission line post insulators are available in four different base mounting configurations: flat
bolt circle base, gain base, bendable gain base, or flat bendable gain base.
Corrosion protection of the steel or iron end fittings is provided by hot-dip galvanizing to CSA G164 and
ASTM A153 specifications.
The standard base end fittings that are available are listed and detailed in the table below. For other
special base end fittings contact K-Line Insulator Limited.

Bolt Circle Base

Gain Base

Curved Bendable Gain Base

Flat Bendable Gain Base

K-LINE INSULATORS LIMITED

CATALOGUE T-SP

TORONTO, ONTARIO, CANADA

Transmission Silicone Insulators


Station Post
69 kV to 161 kV

Transmission Silicone Insulators


Station Post
One of the most critical assets of an electrical Transmission System is the station. Not only is this asset the heart
of the supply to large electrical loads but it also serves many customers from industrial to residential. Therefore,
outages or interruptions due to insulation failures are costly and impact negatively on customer service. With KLine silicone station insulators these are greatly minimized through improved performance to reliability and
savings in the life cycle cost.
Silicones hydrophobic property allows K-Line station insulators to electrically outperform porcelain insulators.
The lightweight feature of polymer insulators makes it easy to handle and install. The size and fittings of polymer
station insulators ensure that they are compatible with existing station post hardware and arrangements.
Experience with silicone polymer insulators has proven their superiority over porcelain insulators.
KLine silicone polymer transmission station post insulators are manufactured and tested to world-class polymer
insulator standards, CSA and ANSI. K-Lines Quality System is registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators transmission station post insulators are listed below.

Improved Reliability (interruptions and outages due to vandalism, and flashovers in all types of
environments are a thing of the past)

Eliminate or Reduce Maintenance (such as washing and trouble calls) and is compatible with existing
porcelain insulators
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation, eliminates catastrophic mechanical failures)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
Transmission station post insulators are used in open-type stations operating at and above 66 kV. These insulators
support the bus, leads, or other apparatus within the station.

Rod
The core rod of the transmission station post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected molded silicone rubber that chemically bonds to the
core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

Transmission Station Post Insulator

TECHNICAL DATA

Catalogue
Voltage
Number
(See Notes 1, Class
2, & 3)
kV
KL69ASP13
KL69ASP16
KL115ASP22
KL115ASP25
KL138ASP28
KL138ASP31
KL161ASP34
KL161ASP37

69

115

138

161

Section
Length
L
mm

(in)

Dry
Arcing
Distance

Leakage
Distance

mm

mm

(in)

(in)

Positive
Impulse
Withstand

kV

Low
Frequency
Flashover
Dry
kV

Wet
kV

Ultimate
Cantilever
Strength
kN

(lbs)

Equivalent
Height to
ANSI
Technical
Reference
Number

762 (30.0)

605 (23.8)

1534 (60.4)

355

245

195

29.9 (6725)

TR216/278

895 (35.2)

742 (29.2)

1890 (74.4)

430

295

240

26.2 (5885)

1143 (45.0) 990 (39.0)

2583 (101.7)

565

385

320

19.7 (4440)

TR286/287

1267 (49.9) 1115 (43.9) 2931 (115.4)

635

430

360

16.5 (3705)

1372 (54.0) 1220 (48.0) 3256 (128.2)

690

470

400

15.1 (3405)

TR288/289

1515 (59.6) 1361 (53.6) 3622 (142.6)

765

520

450

13.3 (2995)

1639 (64.5) 1476 (58.1) 3970 (156.3)

830

555

480

11.7 (2640)

1763 (69.4) 1600 (63.0) 4315 (169.9)

900

595

510

10.2 (2290)

Ordering Information:
1.
2.
3.

Above catalogue numbers apply to insulators with through holes on both ends.
Add T1 to catalogue numbers for insulators with one end tapped & the other with through holes.
Add T2 to catalogue number for insulators with both ends tapped.

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
Tel.: (416) 292-2008 Fax: (416) 292-2094 E-Mail: insulators@k-line.net Web Page: www.k-line.net

End Bases
The standard base fittings are flat round iron bases that are available with bolt circle mounting holes with
either through or tapped holes. These bases are compatible with the porcelain station post insulator
standard.
The end bases are radialy swaged on to the core rod to provide the mechanical performance and reduce
the stress concentration. Our proprietary design insures a watertight seal between the rubber and end
fitting. This special silicone rubber to metal fittings sealing process prevents moisture ingress to the core
fiberglass rod. For other special base requirements, please contact K-Line Insulators Limited.
Corrosion protection of the end bases is provided by hot-dip galvanizing to CSA G164 and ASTM A153
specifications.

K-LINE INSULATORS LIMITED

Catalogue GI

TORONTO, ONTARIO, CANADA

Guy Strain
Polymer Insulators

Guy Strain
Polymer Insulators
Safety codes mandate the elect rical strength of guy insulators to have a dry fl as hover voltage at least twice the
voltage to ground of the highest voltage supply circuit with which the guy could come in contact, and a wet
flashover equal to the highest voltage between any two conductors. When using porcelain, two or more
insulators are usually needed to comply with these requirements.
Fibreglass guy strain insulators so located that there is a possibility of contact with the supply conductors are
prone to electrical tracking and failure. Paint coatings are easily removed in handling, and by weathering, and do
not adequately protect the rod. In chemical environments, crystalline fracture of the unprotected rod can occur.
K-Line guy strain insulators are protected from the environment including the effects of voltage, ultra-violet rays
and acid rain by a fully bonded, electrically track-free, and impenetrable EPDM or Silicone rubber sheath. The
electrical and mechanical requirements of the safety codes are easily met by K-Line Insulators. The insulators are
manufactured under a registered Canadian Standards Association Z299.3-1985 quality assurance program. Each
assembled insulator is proof tested, and permanently marked to show the date of test.

Guy Strain Polymer Insulators

TECHNICAL DATA
SPECIFICATION
INSULATED LENGTH A

CATALOG NUMBER
UNIT

KL-11

KL-24

KL-36

KL-54

KL-78

in (mm)

11 (280)
115
60

24 (610)
235
146

36 (915)
335
235

54 (1370)
485
370

78 (1980)
680
550

22,000(100)
11,700(52)

22,OOO(100)
11.700(52)

22.000(100)
11,700(52)

22,OOO(100)
11,700(52)

42(56)
1.5(.7)
15

42(56)
2 (.9)
15

42(56)
3.3(1.5)
15

42(56)
4.4 (2)
15

DRY
60 Hz FLASHOVER
kV
WET
DESIGN TENSION STRENGTH
Ib (kN
22OOO (100)
Ib (kN)
11,700(52)
TENSION PROOF TEST LOAD
DESIGN TORQUE RATING
ft-lb. (N m)
42(56)
NET WEIGHT
Ib (kg)
1.3(.6)
STANDARD PACKAGE
24
ORDERING INFORMATION:
To catalog number, add suffix CT for clevis-tongue, CC for clevis-clevis, RR
for roller-roller,
or HH for thimble eye-thimble eye

K-LINE INSULATORS LIMITED

Catalogue EI

TORONTO, ONTARIO, CANADA

Extension Insulators

Extension Insulators
K-Line dead-end extension insulators are manufactured by coupling either silicone or EPDM sleeved rod to polymer dead-end insulators.
Extension insulators are made using the same manufacturing methods and quality assurance program as the dead-end and guy strain
insulators. Each dead-end extension insulator is mechanically proof tested to 10,000 lbs.
For installations in normal operating environments, K-Line EPDM insulators are recommended. For extremely contaminated, salt laden or
chemical environments, K-Line SILICONE insulators are the ultimate solution.
The Technical Data table (See Next Section) shows the standard lengths available. Custom lengths are available on request.

Extension Insulators

TECHNICAL DATA
CATALOG
NUMBER
KL15S - 11
KL15S -24
KL15S x36
KL23 x 11
KL23 - 24

KL28E x 11
KL28E -24
KL28E x 36
KL28S 11
KL28S 24
KL28S x 36
KL35 - 11
KL35 -24
KL35 Sir 36
KL46 x 11
KL46 x 24
KL46 of 36
KL46S x 11
KL46S x 24
KL46S x 36
KL46SN x 11
KL46SN x 24
KL46SN x 36

INSULATOR
MATERIAL

Silicone

EPDM

EPDM

Silicone

EPDM

EPDM

Silicone

Silicone

DIMENSIONS
(inches)
'A' 'B'

VOLTAGE CRITICAL
RATING IMPULSE
FLASHOVER
VOLTAGE-

29.5
42.5
545
30.5
43.5
55.5

110
240
360
11.0
24.0
360

340
470
590
0
34
47.1
59.0
35.0
48.0
60.0
39.5
52.5
64.5
39.5
52.5
64.5
38.5
51.5
63.1

11.0
24.0
36.0

STANDARD
PACKAGE
SIZE

15

145

9 UNITS

23

160

5 UNITS

28

215

9 UNITS

28

215

9 UNITS

35

235

5 UNITS

46

300

5 UNITS

46

300

9 UNITS

35

285

9 UNITS

0
11
0
360
110
24.0
360
11.0
24.0
36.0
11.0
24.0
36.0
11.0
24.0
36.0

ORDERING INFORMATION:
Add Suffix S to catalogue number for silicone rod
Note: The critical Impulse flashover voltage values Shown are based on the insulator
Section to"

WEIGHT
(lbs.)
2.6
3.1
3.5
3.5
4.0
44
3.0
3.5
3.9
3.1
3.6
4.1
49
5.4
5.8
5.8
6.3
6.6
3.8
4.3
46
3.4
4.3

Interphase Spacers
Overview
With the environmental exposure to ice and/or wind Overhead Transmission and Distribution
Lines that are bare open-wire design are quite susceptible to conductor motion that may result in
outages or interruptions on the electrical system due to conductor contact, flashovers, or any
plant damage. Interphase spacers were developed to minimize the probability of these
occurrences by insuring that conductors remain apart during their movement.
Interphase Spacer
K Line interphase spacers consist of silicone rubber insulation over a fiberglass rod. They are
very light and flexible. They are connected on the conductor with clamps with or without armour
rods. The interphase spacers meet the requirements of CEA LWIWG-01, IEEE 1024, ANSI
C29.11 and CSA C411.4.
Experience
In the past 20 years many Canadian Utilities such as Ontario Hydro, Manitoba Hydro, and
Hydro-Quebec have installed interphase spacers. Also, they are widely used by other utilities in
countries such as Australia, Germany, Japan, USA, and Switzerland. They have been applies on
distribution and transmission lines operating from 4.16 to 500 kV. There have not been any
problems reported with the K -Line interphase spacers.
Application
One or two interphase spacers are installed in each span. One spacer is installed if there are two
vertically positioned conductors and it is installed at one-third of the span. Two spacers are
installed if there are three vertically positioned conductors. The first spacer is installed between
the mid and lower conductors one-third of the span from one end. The second spacer is installed
between the mid and upper conductor one-quarter of the span from the other end.
Sebastian Marra, P. Eng.
Manager of Engineering
K Line Insulators Limited
August 11, 2000

K-LINE INSULATORS LIMITED

Catalogue D-IPS

TORONTO, ONTARIO, CANADA

DISTRIBUTION SILICONE INSULATORS


Interphase Spacer
15 kV to 69 kV

Distribution Silicone Insulators


Interphase Spacer
With the environmental exposure to ice and/or wind Overhead Transmission and Distribution Lines that
are bare open-wire design are quite susceptible to conductor motion that may result in outages or
interruptions on the electrical system due to conductor contact, flashovers, or any plant damage.
Interphase spacers were developed to minimize the probability of these occurrences by insuring that
conductors remain apart during their movement.
K Line interphase spacers consist of silicone rubber insulation over a fiberglass rod. They are very
light and flexible. They are connected on the conductor with clamps with or without armour rods. The
interphase spacers meet the requirements of CEA LWIWG-01, IEEE 1024, ANSI C29.11 and CSA
C411.4. K-Line Insulators Limited is registered to ISO 9001 Quality Systems.

Performance Benefits
The performance benefits of K-Line Insulators distribution suspension/dead-end insulators are listed below.

Improves Reliability (by minimizes interruptions and outages due to vandalism, pole fires, and flashovers in
all types of environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)

Application
One or two interphase spacers are installed in each span. One spacer is installed if there are two
vertically positioned conductors and it is installed at one-third of the span. Two spacers are installed if
there are three vertically positioned conductors. The first spacer is installed between the mid and lower
conductors one-third of the span from one end. The second spacer is installed between the mid and
upper conductor one-quarter of the span from the other end.

Core Material
The core rod of the distribution suspension/dead-end insulator is made of a high quality fiberglass that has been
specially formulated for electrical and mechanical applications.

Housing and Sheds


The housing and sheds of the insulator are one piece, injected molded silicone rubber that is chemically bonded to
the core rod. This ensues that the interface between the rubber and rod is impenetrable against moisture ingress.

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
x Tel.: (416) 292-2008 x Fax: (416) 292-2094 x E-Mail: insulators@k-line.net x Web Page: www.k-line.net

K-LINE INSULATORS LIMITED


50 Passmore Avenue, Toronto, Ontario, Canada M1V 4T1
x Tel.: (416) 292-2008 x Fax: (416) 292-2094 x E-Mail: insulators@k-line.net x Web Page: www.k-line.net

Riser Support Insulator


In numerous instances a Line Post Insulator is installed to stabilize a conductor drop to maintain safe
operating clearances. This is an expensive solution as compared to K-Line's Riser Support Insulator:
-

light weight

complete with conductor clamp

simply bolt to existing brackets or crossarms or mount to a through bolt on pole

unlimited applications

units available for all distribution voltages

Distribution Riser Support Insulator

Riser Support Insulators


TECHNICAL DATA
SPECIFICATIONS

UNIT

Voltage Class

CATALOGUE NUMBER*
KL15ARSIU

KL28ARSIU

KL46SNRSIU

KL46SRSIU

KL69HRIU16

15

28

35/46

46

69

kV

Section Length L

mm (in)
mm (in)

389 (15.3)

500

(19.7)

594 (23.4)

619 (24.4)

779 (30.7)

Dry Arcing Distance

195

(7.6)

290

(11.4)

389 (15.3)

419 (16.5)

627 (24.7)

Leakage Distance

mm (in)

385 (15.1)

590

(23.2)

853 (33.6)

988 (38.9)

1798 (70.8)

kV

100

155

180

260

Low-Frequency Flashover

Dry
Wet

kV

70

105

135

150

205

kV

145

225

285

300

425

Test

kV

15

20

30

30

44

Max.

Critical Impulse Flashover (Pos.)


Radio Influence Voltage
(RIV) at 1 MHz
Torsional Load
Approx. Weight

135

Below 1

Below 1

Below 5

Below 5

Below 10

Nm (ftlb)

83

(62)

83

(62)

83 (62)

83 (62)

83 (62)

kg (lb)

0.7

(1.5)

0.9

(1.9)

2.1 (4.7)

2.2 (4.8)

2.3 (5.1)

* Options:
For 5/8-11UNC tapped hole add X or for tin-plated clamp add D to the catalogue number.

K-LINE INSULATORS LIMITED

Catalogue MB-PT

TORONTO, ONTARIO, CANADA

Single Circuit
Pole Top Framing Assembly

Single Circuit
Pole Top Framing Assembly
The ultimate in labour saving and convenience is provided by K-Line's single circuit pole-top framing
assembly (35 kV shown). The assembly comes complete in kit form with mounting bracket, polymer line post
insulators, trunnion clamps and insulator mounting studs. Install with two bolts and the structure is ready to
sag.
The hot dip galvanized steel bracket comes with predrilled holes for mounting of riser support insulators and a
grounding lug. The insulators are of silicone, the ultimate in polymer line post insulators for maintenance-free
operation.
.

Clamps
Trunnion Clamp

Part No.

Material

KLOP26AL

Aluminum

KLOP26I

Mallealbe iron

KLOP173

Aluminum

Studs

Conductor Range
0.25 1.07
(6.4mm 27.2mm)
0.25 1.07
(6.4mm 27.2mm)
1.00 1.50
(25.4mm 38.1mm)

3 Standoff Bracket (armless)

Part No.: KLOP149

9 Side Post Bracket

Part No.: KLOP56

Standard Guy Strain Roller

Part No.: HW11