Sie sind auf Seite 1von 9

RNC Preventive Maintenance

Exercises

Nokia Siemens Networks

1 (9)

RNC Preventive Maintenance

Legal notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training
documentation, product documentation and slide presentation material, all of which are
forthwith known as Nokia Siemens Networks training material, are the exclusive property of
Nokia Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification,
translation, adaptation or derivatives including any improvements or developments. Nokia
Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license,
sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals
can use the Nokia Siemens Networks training material for their own personal selfdevelopment only, those same individuals cannot subsequently pass on that same Intellectual
Property to others without the prior written agreement of Nokia Siemens Networks. The Nokia
Siemens Networks training material cannot be used outside of an agreed Nokia Siemens
Networks training session for development of groups without the prior written agreement of
Nokia Siemens Networks.
Indemnity
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This document is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under
which the document is submitted, and no part of it may be used, reproduced, modified or
transmitted in any form or means without the prior written permission of Nokia Siemens
Networks. The document has been prepared to be used by professional and properly trained
personnel, and the customer assumes full responsibility when using it. Nokia Siemens
Networks welcomes customer comments as part of the process of continuous development
and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given as is and all liability
arising in connection with such hardware or software products shall be defined conclusively in
a separate agreement between Nokia Siemens Networks and the customer. However, Nokia
Siemens Networks has made all reasonable efforts to ensure that the instructions contained in
the document are adequate and free of material errors and omissions. Nokia Siemens
Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may
not be covered by the document.
Nokia Siemens Networks will correct errors in the document as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENT OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY MONETARY
LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS
INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE
USE OF THIS DOCUMENT OR THE INFORMATION IN IT
This document and the product it describes are considered protected by copyrights and other
intellectual property rights according to the applicable laws.
Wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2007. All rights reserved.

2 (9)

Nokia Siemens Networks

RNC Preventive Maintenance

Contents
1.

Objectives....................................................................................4

2.
2.1
2.2
2.3

Alarm System..............................................................................5
Active alarms and alarm history handling .....................................5
Alarm Blocking..............................................................................5
Alarm Cancelling...........................................................................6

3.

Recovery System........................................................................7

4.

Unit Diagnostics .........................................................................8

5.

Command Calendar....................................................................9

Nokia Siemens Networks

3 (9)

RNC Preventive Maintenance

1.

Objectives
After completing this learning element exercise, participant should be
able to:

4 (9)

Display alarm history

Display and cancel active alarms

Operate alarm administration: alarm blocking

Handle unit working state for recovery actions and replacing plug
in unit.

Run diagnostics.

Create and run command calendar

Nokia Siemens Networks

RNC Preventive Maintenance

2.

Alarm System
1.

Display the Alarm System Administration menu.


Command: ________________________________________

2.

Display the Alarm Parameters Handling menu.


Command: ________________________________________

3.

Display the menu for Handling Active Alarms.


Command: ________________________________________

2.1

Active alarms and alarm history handling


1.

By referring to the Alarm Reference Manual, find out which fault


causes the alarm with the alarm number 2692?
_________________________________________________

2.

Display all alarms currently active alarms.


Command: ________________________________________

3.

Display all ** alarms and *** alarms for the OMU.


Command: ________________________________________

4.

Display ** alarms which have been active since two days ago.
Command: ________________________________________

5.

Look for all working state change notices (alarm number 690) of
the OMU since last month.
Command: ________________________________________

6.

Show all the alarms that have appeared in the RSMU today after 8
a.m.
Command: ________________________________________

7.

2.2

What is the difference between alarm history and active alarms?


(Hint: Check the listings!)

Alarm Blocking
1.

Find the command group for alarms blocking


Command: ________________________________________

2.

Output blocked alarms.


Command: ________________________________________

Nokia Siemens Networks

5 (9)

RNC Preventive Maintenance

3.

Block the alarm 2692 that concerns the RSMU unit and check the
result.
Command: ________________________________________
Command: ________________________________________
Now test the blocking:

4.

First change the units state to TE and then change its state back
to SP. Always check active alarms (look for printout time). Check
alarm history.
Command: ________________________________________
Command: ________________________________________

5.

Now unblock the alarm and change again the units state first to
TE and then back to SP. Check active alarms and alarm history.
Command: ________________________________________
Command: ________________________________________

6.

What is the difference in alarm history in exercises 4 & 5?


_________________________________________________

7.

Can a blocked alarm activate recovery?


_________________________________________________

8.

What is the difference between the parameters RES and TOT in


the alarm blocking command?
_________________________________________________

2.3

Alarm Cancelling
1.

What is the command group for Alarm Cancelling?


_________________________________________________

2.

Find an active alarm and its consecutive number, then cancel this
alarm concerning to its consecutive number.
Command: ________________________________________
Command: ________________________________________

3.

Cancel the alarms concerning the RSMU unit.


Command: ________________________________________

4.

When should you cancel an alarm?


_________________________________________________

6 (9)

Nokia Siemens Networks

RNC Preventive Maintenance

3.

Recovery System
1.

Display Unit's Working State and Restart Handling menu.


Command: ________________________________________

2.

Interrogate working states of all units.


Command: ________________________________________

3.

Change the working state of the spare ICSU to SE-NH, and then
verify the LED light colour on the computer unit.
Command: ________________________________________
LED colour:________________________________________

Note: now you can simulate how to change the plugin unit.
4.

Restore the situation.


Command: ________________________________________

5.

Execute a switchover in a RSMU unit.


Command: ________________________________________

6.

List the units in spare working state.


Command: ________________________________________

7.

List all the faulty units in the system.


Command: ________________________________________

8.

Execute a warm restart in the spare ICSU unit.


Command: ________________________________________

Nokia Siemens Networks

7 (9)

RNC Preventive Maintenance

4.

Unit Diagnostics
1.

Display the menu of the Diagnostics Handling command group.


Command: ________________________________________

2.

Interrogate the partial diagnosis tests defined for the spare RSMU.
Command: ________________________________________

3.

Execute a diagnosis in spare RSMU. Study the diagnostics printout.


(Hint: Have a look at the alarm printing port of the OMU. Check the
output.)
Command: ________________________________________

4.

Check which diagnostics tests are being executed in the


exchange.
Command: ________________________________________

5.

Stop current tests.


Command: ________________________________________

6.

Printout diagnostic result for corresponding unit


Command: ________________________________________

7.

List all the computer units marked faulty by the recovery system.
Command: ________________________________________

8.

Run diagnoses on I/O-devices, e.g. FDU


Command: ________________________________________

8 (9)

Nokia Siemens Networks

RNC Preventive Maintenance

5.

Command Calendar
1.

Verify that there is still enough space for creating SW package in


SOMAFI
Command: ________________________________________

2.

Verify current system time is correct


Command: ________________________________________

3.

Add a command calendar to start fallback copying with the


following parameter
Starting time : 10 minutes from current time
Save the command after execution
Fallback mode : FULL
Package name : EXERCISE
Directory name : EXERCISE
Command: ________________________________________

4.

Verify the recently added command calendar


Command: ________________________________________

5.

Wait until the execution time and verify that there is a fallback
copying task on progress
Command: ________________________________________

6.

Edit the previous task to match the following criteria


Fallback copying mode : ARCHIVE
Repetition : everyday at 23:59
Repetition limit : NO
Command: ________________________________________

7.

Verify the recently modified command calendar


Command: ________________________________________

Nokia Siemens Networks

9 (9)

Das könnte Ihnen auch gefallen