Specifications - Engineering Data - Dimensions

VERTICAL
RECIRCULATORS

E120-220 SED
Page 2

VERTICAL RECIRCULATORS
SPECIFICATIONS-ENGINEERING DATA-DIMENSIONS

NOTES:
1. All dimensions and nozzle nominal pipe sizes are given in inches unless noted otherwise.
2. Operating charge at OPL is based on ammonia @ +0F RT having a density of 41.3654 lbf at this temperature.
3. Liquid makeup connection is on the top of the wet return connection. Wet return connection sized for concurrent return
and liquid makeup flow.
4. Nozzles are sized for R-717 and should not be used with other refrigerants (e.g. R-22 & R-507).
5. Nozzle connections are supplied as pipe stubs unless otherwise specified as a coupling (Cplg).
6. Couplings are ASME B16.11 Class 3000 "full" couplings.
7. Use minimum 8-inch standoff on nameplate bracket.
8. All dimensions are subject to change; please consult factory for certified drawings.
9. Vessels are built in accordance with ASME Boiler & Pressure Vessel Code, Section VIII, Division 1.
Key to Nozzle/Coupling Locations:
A - Wet Return
B - Gas Outlet
C - Liquid Makeup
E - Level Column
F - Pump Suction
G - Relief (Coupling)
H - Oil Drain

I - Oil Pot Vent


J - Volute Vent/Bleed
K - Liquid Bypass
OD - Outside Diameter
HD - Head Depth
L - Shell Length
OAL - Overall Length

Figure 1. Data and Dimensions

LLCO - Low Level Cutout


OPL - Operating Level
HLCO - High Level Cutout

VERTICAL RECIRCULATORS
SPECIFICATIONS-ENGINEERING DATA-DIMENSIONS

E120-220 SED
Page 3

VERTICAL RECIRCULATOR CAPACITIES R-717

Model No.
VRC-24-110
VRC-30-113
VRC-36-116
VRC-42-143
VRC-48-146
VRC-54-149
VRC-60-152
VRC-72-158
VRC-84-164
VRC-96-170
Separation
Velocity (4)
1.
2.
3.
4.

Two Stage (2)


-40F
-30F
64.2
77.7
102
124
147
178
202
244
262
317
333
404
413
500
595
720
804
973
1050
1271

-50F
51.9
82.8
119
163
212
269
334
480
649
848
227.5

210

Operating Temperature
Single Stage (3)
-20F
-10F
0F
10F
20F
80
92.6
104
119
134
127
147
167
191
214
184
213
240
275
308
252
291
329
377
423
327
378
427
489
549
416
481
543
622
698
515
596
674
771
865
741
858
969
1109
1244
1002
1159
1310
1499
1682
1308
1514
1711
1958
2196

-20F
92
146
211
289
376
478
592
852
1152
1505

192.5

(1)

175

175

157.5

140

127.5

115

30F
147
235
339
464
603
766
950
1366
1847
2412

40F
158
252
363
492
646
822
1019
1465
1981
2587

102.5

90

Capacities are given in tons of refrigeration (R-717).


Two-stage capacities based on +35F liquid feed temperature.
Single-stage capacities based on +95F liquid feed temperature.
Separation velocities are given in feet per minute.

DIMENSIONAL DATA
Model
Number
VRC-24-110
VRC-30-113
VRC-36-116
VRC-42-143
VRC-48-146
VRC-54-149
VRC-60-152
VRC-72-158
VRC-84-164
VRC-96-170

MAWP
250
250
250
250
250
250
250
250
250
250

Model No.
VRC-24-110
VRC-30-113
VRC-36-116
VRC-42-143
VRC-48-146
VRC-54-149
VRC-60-152
VRC-72-158
VRC-84-164
VRC-96-170

C
1
2
2
2 1/ 2
3
3
3
4
4
5

E
1
1
1
1
1
1
1
1
1
1

OD
24
30
36
42
48
54
60
72
84
96

OAL
110 3/8
113 3/8
116 3/8
143 3/8
146 1/2
149 1/2
152 1/2
158 5/8
164 3/4
170 3/4
F
4
5
5
5
5
6
6
8
8
8

G
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
1
1

HD
8 3/16
9 11/16
11 3/16
12 11/16
14 1/4
15 3/4
17 1/4
20 5/16
23 3/8
26 3/8
H
1
1
1
1
1
1
1
1
1
1

I
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4

L
94
94
94
118
118
118
118
118
118
118
J
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4

K
1
1
1
1
1
1
1
2
2
2

Dry
Weight
(lbf)
1,020
1,310
1,610
2,310
3,590
4,120
4,670
7,270
10,560
12,510
AL
78 1/2
80 1/2
85
109
108
108
106
106
104
102

R-717
Operating
Charge
(lbf)
159.4
244.3
343.1
453.9
564.1
691.0
823.5
1645.0
2095.4
2917.2

BL
EL EL2
89
57
3
88 57 1/2
3
88
73
6
112
96
3
108
93
6
108
93
6
106
93
6
106
89
10
108
89
10
106
87
12

Surge
Vol.
(cu ft) LLCO OPL HLCO
10.56
8
18
61
17.50
8
18
63
27.11
8
18
66
56.46
10
18
91
71.29
10
18
89
91.92
10
18
90
109.17
12
18
87
150.16
12
24
90
197.99
14
24
88
243.53
14
26
86
FL
9
10
10
12
12
14
16
18
20
24

GL
7.5
7.5
10
11
16
16
16
20
24
24

IL
10.5
10.5
10.5
10.5
13.5
13.5
13.5
13.5
13.5
13.5

JL
9
10
10
12
12
14
16
18
20
24

JL2
6
8
9
12
14
16
16
16
16
16

A
5
6
8
8
10
10
10
12
14
16
KL
7
7
9
9
9
9
9
9
9
9

B
4
5
6
6
8
8
8
10
10
12
KL2
6
6
9
14
16
18
18
18
21
24

Q-NET network technology...


make the connection with QUANTUM!
Preengineering = Lower Cost
Totally distributed units means remote control using single cable
Upgradeable

System integration is what we do


" Q-NET supports open-protocols for your SCADA system
(i.e. Allen Bradley DF1 and Modbus ASCII)

"
"

Q-NET connects for local or remote access


Q-NET can be applied to both new and existing systems

Q-NET means precise control 24 hours a day, seven days a week

Q-NET distributed architecture means faster, easier, economical installations

Q-NET delivers increased operating efficiency and lowers energy costs

Now available on Fricks ACUair hygienic air handlers, PowerFlow condensers,


screw compressors, evaporators, and refrigerant vessels, too.
For more information on how Q-NET Network Technology can enhance the performance of your job site, contact Frick Controls at 717-762-2121 or visit our website
(www.frickcold.com) for a complete listing of Frick sales offices and Frick Factor
Distributors.

Take full advantage of Q-NET technology with all Frick products!

YORK Refrigeration
100 CV Avenue P.O. Box 997 Waynesboro, Pennsylvania USA 17268-0997
Phone: 717-762-2121 FAX: 717-762-8624 www.frickcold.com
Subject To Change Without Notice

2002, YORK Refrigeration

Das könnte Ihnen auch gefallen