Sie sind auf Seite 1von 9

Job No

Company Name

Sheet No

Rev

1
Part

Job Title

Ref

khkli

By
Client

Date

22-Mar-16

File

Chd

Date/Time

Job Information
Engineer
Name:
Date:

Checked

Approved

22-Mar-16

Structure Type

SPACE FRAME

Number of Nodes
Number of Elements
Number of Plates

4
3
0

Highest Node
Highest Element
Highest Plate

Number of Design Groups


Number of Design Slabs
Number of Load Cases
Number of Design Briefs

4
3
0

2
0
1
2

Included in this printout are data for:


Design Group
Design Brief
G2: Design Group 2

Design Code

B2: column

Members

AS3600 Column

M1, M3

Design Group Summary - Design Group 2


Member

Design

M1
Initial
M3
Initial
Summary: the group is safe

Type
Column
Column

Main Bars
Major
Minor
Ok
Ok

Shear
Local z Local y

Ok
Ok

Ok
Ok

Ok
Ok

Column Input Data


Member

Type

M1
M3

Column
Column

Length
(m)
4.000
4.000

Eff. Length Factors


Major
Minor
1.00
1.00

Braced
Major
Minor

1.00
1.00

Yes
Yes

Yes
Yes

Cover
(cm)

Link
Size

3.0
3.0

6
6

Column Main Reinforcement


Member

L/C

M1
L1
M3
L1
Summary: the group is safe

Print Time/Date: 22/03/2016 14:29

Axial
(kN)
45.000
45.000

Major
(kNm)
12.157
12.157

Minor
(kNm)
0.000
0.000

Design
Axis
maj
maj

STAAD.Pro - RC AS 3600 Version 1.0

As Req.
(mm 2)

Total
Bars

900
900

12N12
12N12

As Prov.
(mm 2)
905
905

Print Run 1 of 9

Job No

Company Name

Sheet No

Rev

2
Part

Job Title

Ref

khkli

By
Client

Date

Chd

22-Mar-16

File

Date/Time

Column Shear Reinforcement


Member

L/C

Max Shear in local y


Value
Position
(kN)
(m)

M1
L1
M3
L1
Summary: the group is safe

4.539
4.539

L/C

Max Shear in local z


Value
Position
(kN)
(m)

L1
L1

0.000
0.000

0.000
0.000

Asv Req.
(mm 2)

0.000
0.000

50
50

Link
Size

Spacing
(cm)
6
6

12.5
12.5

Members
Member Element
M1
M3

3
2

Node
A

Node
B

1
2

4
3

Property

Emt Length
(m)

300 x 300
300 x 300

O. Length
(m)

4.000
4.000

4.000
4.000

Member 1 - Scheduled Bars


Bar
Mark

Type and
size

01
02
03

N12
R6
R6

No. of
bars
12
32
128

Bar Length
(mm)

Shape
code

4000
1050
525

20
61
97

A
(mm)
240
100

B
(mm)
240
105

C
(mm)

D
(mm)

E/R
(mm)

D
(mm)

E/R
(mm)

240

Member 3 - Scheduled Bars


Bar
Mark

Type and
size

01
02
03

N12
R6
R6

Print Time/Date: 22/03/2016 14:29

No. of
bars
12
32
128

Bar Length
(mm)
4000
1050
525

Shape
code
20
61
97

A
(mm)
240
100

B
(mm)
240
105

C
(mm)

240

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 2 of 9

Job No

Company Name

Sheet No

Rev

3
Part

Job Title

Ref

khkli

By
Client

Date

22-Mar-16

File

Chd

Date/Time

Member 1 - Detailed AS 3600 Design Requirements


Section Property: 300 x 300
Storey height
= 4.000 m
Rectangular section:
Width
Cover

= 300 mm
= 30 mm

Depth

= 300 mm

Member 1 - Detailed AS 3600 Main Reinforcement


Shear bars not designed. Depth of main reinforcement taken as cover + brief link size
Axial N
= 45.00 kN
Major M,
M1,
= 6.00 kNm
M2,
= -12.16 kNm
Minor M,
M1,
= 0.00 kNm
M2,
= -0.00 kNm
Warning - Low compression stress. This member may be better designed as a beam.
Column Type:
SLENDER

10.3.1

Design Mx
Design My

= 12.16 kNm
= 0.00 kNm

10.3.1
10.3.1

Total area of steel required


2
Area of steel required at column =faces
452 in
mm
design
axis
Total area of steel provided
Area of steel provided at faces

= 900 mm 2 (nominal)

Force produced by concrete stress block


Force produced by main steel
internal forces
Internal forces axial N

= 177.80 kN
= -132.80 kN
= 45.00 kN
OK for axial resistance

Internal Moment
Design Moment
Internal moments design moment

= 34.20 kNm
= 12.16 kNm
OK for moment resistance

Min distance between bars


= hagg + 5 mm or bar diameter
Smallest actual space between bars
Max allowable spacing of bars in designed faces =
Largest actual clear space between bars in designed faces
Max allowable spacing of bars in other faces
Largest actual clear space between bars in other faces

= 25 mm
= 60 mm
= 300 mm
= 60 mm
= 300 mm
= 60 mm

Actual area of main reinforcement (12N12)


Min area of compression reinforcement
Max area of reinforcement
Actual area of main reinforcement

= 1357.16 mm 2
= 1.0 %
= 4%
= 1.51 %

= 1357.16 mm 2
= 904.78 mm 2

10.7.1
10.7.1

OK

Print Time/Date: 22/03/2016 14:29

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 3 of 9

Company Name

Job No

Sheet No

Rev

4
Part

Job Title

khkli

Ref
By

Client

Date

File

22-Mar-16

Chd

Date/Time

Member 1 - Detailed AS 3600 Shear Reinforcement


Spacing provided, sv
Major axis:
Shear force, V
V
v
=
bv d
vc
Area of links required = 0.35 bvsv / 0.70 fyv
Area of links provided (4R6), Asv
Minor axis:
Shear force, V
V
v
=
bv d
vc
Area of links required = 0.35 bvsv / 0.70 fyv
Area of links provided (4R6), Asv
Minimum size of link bars
Actual size of link bars
Maximum spacing of links

Print Time/Date: 22/03/2016 14:29

= 125 mm
= 4.54 kN
= 0.08 N/mm 2

8.2

= 3.92 N/mm 2
= 52.50 mm 2
= 113.10 mm 2

8.2.1

= 0.00 kN
= 0.00 N/mm 2

8.2

= 3.92 N/mm 2
= 52.50 mm 2
= 113.10 mm 2

8.2.1

= 6 mm
= 6 mm
= 129 mm
OK

STAAD.Pro - RC AS 3600 Version 1.0

8.2.12.2

Print Run 4 of 9

Job No

Company Name

Sheet No

Rev

5
Part

Job Title

Ref

khkli

By
Client

Date

22-Mar-16

File

Chd

Date/Time

Member 3 - Detailed AS 3600 Design Requirements


Section Property: 300 x 300
Storey height
= 4.000 m
Rectangular section:
Width
Cover

= 300 mm
= 30 mm

Depth

= 300 mm

Member 3 - Detailed AS 3600 Main Reinforcement


Shear bars not designed. Depth of main reinforcement taken as cover + brief link size
Axial N
= 45.00 kN
Major M,
M1,
= -6.00 kNm
M2,
= 12.16 kNm
Minor M,
M1,
= 0.00 kNm
M2,
= -0.00 kNm
Warning - Low compression stress. This member may be better designed as a beam.
Column Type:
SLENDER

10.3.1

Design Mx
Design My

= 12.16 kNm
= 0.00 kNm

10.3.1
10.3.1

Total area of steel required


2
Area of steel required at column =faces
452 in
mm
design
axis
Total area of steel provided
Area of steel provided at faces

= 900 mm 2 (nominal)

Force produced by concrete stress block


Force produced by main steel
internal forces
Internal forces axial N

= 177.80 kN
= -132.80 kN
= 45.00 kN
OK for axial resistance

Internal Moment
Design Moment
Internal moments design moment

= 34.20 kNm
= 12.16 kNm
OK for moment resistance

Min distance between bars


= hagg + 5 mm or bar diameter
Smallest actual space between bars
Max allowable spacing of bars in designed faces =
Largest actual clear space between bars in designed faces
Max allowable spacing of bars in other faces
Largest actual clear space between bars in other faces

= 25 mm
= 60 mm
= 300 mm
= 60 mm
= 300 mm
= 60 mm

Actual area of main reinforcement (12N12)


Min area of compression reinforcement
Max area of reinforcement
Actual area of main reinforcement

= 1357.16 mm 2
= 1.0 %
= 4%
= 1.51 %

= 1357.16 mm 2
= 904.78 mm 2

10.7.1
10.7.1

OK

Print Time/Date: 22/03/2016 14:29

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 5 of 9

Company Name

Job No

Sheet No

Rev

6
Part

Job Title

khkli

Ref
By

Client

Date

File

22-Mar-16

Chd

Date/Time

Member 3 - Detailed AS 3600 Shear Reinforcement


Spacing provided, sv
Major axis:
Shear force, V
V
v
=
bv d
vc
Area of links required = 0.35 bvsv / 0.70 fyv
Area of links provided (4R6), Asv
Minor axis:
Shear force, V
V
v
=
bv d
vc
Area of links required = 0.35 bvsv / 0.70 fyv
Area of links provided (4R6), Asv
Minimum size of link bars
Actual size of link bars
Maximum spacing of links

Print Time/Date: 22/03/2016 14:29

= 125 mm
= 4.54 kN
= 0.08 N/mm 2

8.2

= 3.92 N/mm 2
= 52.50 mm 2
= 113.10 mm 2

8.2.1

= 0.00 kN
= 0.00 N/mm 2

8.2

= 3.92 N/mm 2
= 52.50 mm 2
= 113.10 mm 2

8.2.1

= 6 mm
= 6 mm
= 129 mm
OK

STAAD.Pro - RC AS 3600 Version 1.0

8.2.12.2

Print Run 6 of 9

Job No

Company Name

Sheet No

Rev

7
Part

Job Title

Ref

khkli

By
Client

Date

File

22-Mar-16

Chd

Date/Time

Design Group: Design Group 2 - Brief Detail: column AS3600 Column


Group Data
Concrete strength class
Aggregate size
Cover

32

Min. Main Bar


Max. Main Bar
Min. Shear Bar

20
30

12
40
6

Main Reinforcement
Main bars: N(500)

Shear Reinforcement
Shear bars: R(250)

Column Factors
Bracing conditions
Braced y-y
Braced z-z
Slenderness K

Eff. length factors


y-y
z-z

Yes
Yes
Calculated

Starter bar area

1.00
1.00
804 mm 2

Member Loadcases Considered


L1:

LOAD CASE 1

List of Design Groups - concrete Column


Design Group
G1
G2

Design Group 1
Design Group 2

Brief
beam
column

List of Design Briefs - concrete Column


Brief
1
2

beam
column

Print Time/Date: 22/03/2016 14:29

Code
AS3600 Beam
AS3600 Column

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 7 of 9

Job No

Company Name

Sheet No

Rev

8
Part

Job Title

Ref

khkli

By
Client

Date

File

22-Mar-16

Chd

Date/Time

Brief Detail: beam AS3600 Beam


Group Data
Top cover
Bottom cover
Side cover
Envelope

30
30
30
ENVELOPE 1

Aggregate size
Concrete Grade
Beam segments

20
32 MPa
12

Main Reinforcement
Main bars: N(500)

Main Bar Criteria


Top Bar Criteria
Min. bar size
12
Max. bar size
40
Link hanger size
12
Min. layer gap
32
Side bars controlled by minimum size of 12

Bottom Bar Criteria


12
40
12
32

Shear Reinforcement
Max. shear considered at
Enhanced shear at supports
Axial load effects

Centre of supports
Excluded
Excluded

Shear Bar Criteria


Shear bars: N(500)
Min. size
Min. number of legs

Print Time/Date: 22/03/2016 14:29

6
2

Min. spacing
Link style

25 mm
Closed

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 8 of 9

Job No

Company Name

Sheet No

Rev

9
Part

Job Title

Ref

khkli

By
Client

Date

File

22-Mar-16

Chd

Date/Time

Brief Detail: column AS3600 Column


Group Data
Concrete strength class
Aggregate size
Cover

32

Min. Main Bar


Max. Main Bar
Min. Shear Bar

20
30

12
40
6

Main Reinforcement
Main bars: N(500)

Shear Reinforcement
Shear bars: R(250)

Column Factors
Bracing conditions
Braced y-y
Braced z-z
Slenderness K

Eff. length factors


y-y
z-z

Yes
Yes
Calculated

Starter bar area

1.00
1.00
804 mm 2

Member Loadcases Considered


L1:

LOAD CASE 1

Print Time/Date: 22/03/2016 14:29

STAAD.Pro - RC AS 3600 Version 1.0

Print Run 9 of 9

Das könnte Ihnen auch gefallen