Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . .
Symbol Definitions . . . . . . . . . . . . . . . . . . .
Safety Instructions . . . . . . . . . . . . . . . . . . .
Caution . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Contents . . . . . . . . . . . . . . . . . . .
MDVR (IPS700A) Sample System Configuration .
Connectors . . . . . . . . . . . . . . . . . . . . . . . .
Connect Input Sources . . . . . . . . . . . . . . . .
Connect Output to Video Display . . . . . . . . . .
Connect Power . . . . . . . . . . . . . . . . . . . . .
Connect Audio and Mechanical Switch . . . . . .
Connect a Remote Control Device . . . . . . . . .
Methods of Operation . . . . . . . . . . . . . . . . .
Front Panel Control Keypad (OSD) . . . . . . . . .
General Specification . . . . . . . . . . . . . . . . .
Mechanical Drawing . . . . . . . . . . . . . . . . . .
Troubleshooting. . . . . . . . . . . . . . . . . . . . .
Cleaning Instructions . . . . . . . . . . . . . . . . .
Contacts. . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 3
. 4
. 5
. 6
. 9
10
11
12
12
13
13
14
15
16
18
22
23
23
24
The specifications and information in this document are subject to change without notice.
2 - English
FSN1949 - 01/2016
Overview
MDVR, part number IPS700A, is a medical digital video recorder from FSN Medical Technologies.
It is intended to record and store video and still images from operating devices for later playback
or transfer to other media.
MDVR is an advanced high quality video processing system that has built-in capabilities for
signal source selection and multiple resolutions. MDVR is controlled through an Android app. (for
RS232C or TCP/IP control, please consult the manufacturer).
Recording medical digital video is easy with MDVR. An accompanying control tablet runs the intuitive user interface and gives quick access to options for setup, recording, capture, file storage,
patient information, play back, and data backup functions.
In addition, capture and recording can be controlled through an endoscopic camera head buttons or a foot pedal accessory.
All recorded files are stored on MDVRs internal hard disk drive. These stored files can then
be played back on a display monitor, or restored to variety of media including external drives,
memory sticks, DVDs, Bluray disks, and network servers.
All MDVR inputs correspond with universal standards that accept VGA, DVID (up to 1920x1080
resolution), composite video, and Svideo inputs.
FSN1949 - 01/2016
English - 3
Symbol Definitions
The following symbols appear on the product, its labeling, or the product packing. Each symbol
carries a special definition, as defined below:
AC Voltage
Switches on power
Power adapter
Indicates top-bottom
direction
Serial Number
Manufacturer
Maximum Stacking
Fragile
Humidity limitation
Temperature limitation
Equipotentiality.
FSN1949 - 01/2016
Do not disassemble
Do not touch
Power
Use only a proper plug and voltage.
Improper power may cause electric shock or equipment damage.
To avoid the risk of electric shock, this equipment must only be connected to a
power supply with protective grounding.
Installation
Do not connect any other wires or accessories to this system which do not comply.
An improper wire may cause electric shock or equipment damage.
Insert wires firmly so that they do not come loose.
A bad connection may cause fault.
Operating environment
Be sure to contact this products supplier when installing your system in a location
with heavy dust, high or low temperatures, high humidity, or chemical substances.
Failure to do so may cause serious damage to your system.
Others
If this system does not operate normally, in particular, if there are any unusual
sounds or smells coming from it, unplug it immediately.
Please contact supplier when you want to use this system with unknown equipment. Please power off and pull out the power cord when you want to move this
system.
FSN1949 - 01/2016
English - 5
Caution
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
This symbol alerts the user that important literature concerning the operation of this unit
has been included. Therefore, it should be read carefully in order to avoid potential problems.
This symbol warns the user that un-insulated voltage within the unit may have sufficient
magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part
inside the unit.
To reduce the risk of electric shock, DO NOT remove cover (or back). There are no user serviceable parts inside. Refer servicing to qualified service personnel.
To prevent fire or shock hazards, do not expose this unit to rain or moisture. Also, do not use this
units polarized plug with an extension cord receptacle or other outlets unless the prongs can be
fully inserted.
The equipment is designed to meet the medical safety requirements for a patient vicinity device.
This device may not be used in connection with life support equipment.
6 - English
FSN1949 - 01/2016
If the power source is a 240 V AC supply, use the tandem (T blade) type attachment plug with
ground conductor power cord that meets the respective European countrys safety regulations.
The hospital-grade plug for medical products intended for use in Denmark has DEMKO approval
and is rated 13 amps at 250Vac. Plug is recommended for use in medical applications and specifications are being added to the standard SB 107-2-D1. Plug mates with makers Danish hospitalgrade socket. Hospital sockets have slightly different shaped openings allowing only the hospital
plug, not the standard Danish plug, to be inserted, to protect the ac circuit in specific medical
settings.
FCC WARNING :
This equipment has been tested and found to comply with the limits of a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against interference. This system can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, it may interfere with other radio communications
equipment.
There is no guarantee that interference will not occur in a particular installation. If this equipment
is found to cause harmful interference to radio or television reception, the user is encouraged to
try to correct the interference by carrying out one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the distance between this system and the subject of interference.
3. Plug this system into an outlet on a different electrical circuit than that to which the subject of
interference is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
NOTICES TO USER :
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1 )this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment generates or uses radio frequency energy. Changes or modifications to this
equipment may cause harmful interference unless the modifications are expressly approved in
the instruction manual.
The user could lose authority to operate this equipment if an unauthorized change or modification is made.
FSN1949 - 01/2016
English - 7
Recycling :
Follow local governing ordinances and recycling plans regarding the recycling or disposal of this
equipment.
Servicing
Do not attempt to service the system yourself as opening or removing covers may expose you
to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel. Unplug the system from its power source and refer servicing to qualified
personnel under the following conditions:
-If the power cord or plug is damaged or frayed.
-If liquid has been spilled into the system.
-If objects have fallen into the system.
-If the system has been exposed to rain or moisture.
-If the system has been subjected to excessive shock by being dropped.
-If the enclosure has been damaged.
-If the system seems to be overheated.
-If the system emits smoke or abnormal odor.
-If the system fails to operate in accordance with the operating instructions.
Accessories
Use only accessories specified by the manufacturer, or sold with the system.
Classification
Protection against electric shock : Class I including AC/DC power.
Applied Parts : No Applied Parts
Degree of safety in the presence of flammable anesthetics mixture with air or with oxygen or
with nitrous oxide. Not suitable for use in the presence of a flammable anesthetics mixture with
oxygen or with nitrous oxide.
Mode of operation : Continuous.
8 - English
FSN1949 - 01/2016
Package Contents
4
1
5
2
Item
1
2
3
4
5
6
7
Description
MDVR (IPS700A) unit . . . . . . . . . .
User Guide . . . . . . . . . . . . . . . .
AC power Cord (6ft, Medical Grade)
D-SUB cable (6ft) . . . . . . . . . . . .
DVI cable (6ft) . . . . . . . . . . . . . .
BNC cable for Video (6ft). . . . . . . .
SVHS cable for Video (6ft). . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Pack Qty
. . .1
. . .1
. . .1
. . .1
. . .1
. . .1
. . .1
FSN1949 - 01/2016
English - 9
Saved to Media:
t$%
t%7%
t#MVSBZ
t64#
t'514FSWFS
Display Monitor
Playback
Medical Digital
Video Recorder
Control
Interface
Source Signals
t7("
t%7*%
t$7#4
t47JEFP
t"VEJP
10 - English
FSN1949 - 01/2016
Connectors
3
7
2
12
11
10
14
15
17
19
16
18
21
13
20
Blu-ray Disk
13
Network port
USB
14
USB
LCD
15
RS232C
Capture button
16
DVI-D out
Record button
17
VGA out
Stop button
18
DVI-D in
Direction button
19
VGA in
Enter button
20
CVBS in
Menu button
21
CVBS out
10
Earth Terminal
22
S-Video in
22
23
24
11
AC ON/OFF SWITCH
23
Audio in/out
12
AC in
24
FSN1949 - 01/2016
English - 11
Connect input
video signals here.
Connect a video
display here.
12 - English
FSN1949 - 01/2016
Connect Power
Only use the specified plug and voltage. Power requirements are: AC 100~240V / 50~60Hz , 2A(max).
Use the supplied 6 ft. hospital grade AC power cord. Improper power may cause electric shock or
equipment damage. To avoid the risk of electric shock, this equipment must only be connected
to a power supply with protective grounding.
MDVR back panel
FSN1949 - 01/2016
English - 13
Example:
Touch screen tablet connection
using a wireless router. For specific
instructions, see the user guide for
the remote control device that will be
connected to MDVR.
Example:
Direct wire touch screen tablet connection. For specific instructions, see
the user guide for the remote control
device that will be connected to
MDVR.
14 - English
FSN1949 - 01/2016
Methods of Operation
Most features in the MDVR unit are intuitively handled by a remote control device, such as a
touch screen tablet and interface software. Capture and record functions are designed for easy
end user operation via the tablet interface. There are a few configuration settings that can only
be accessed through MDVRs front keypad and LCD. Following is a list of features found in MDVR,
followed by the methods that are available for use.
Main User
Primary Operation
Secondary Operation
Capture Image
MDVR Feature
OR Staff
Tablet
Record Video
OR Staff
Tablet
OR Staff
Tablet
OR Staff
Tablet
OR Staff
Tablet
OR Staff
Tablet
OR Staff
Tablet
Convert to DICOM
Set File Type
OR Staff
Tablet
Installer or Admin.
Tablet
Installer or Admin.
Tablet
Installer or Admin.
Tablet
OR Staff
Tablet
DHCP Setup
Installer or Admin.
Tablet
Installer or Admin.
Tablet
OR Staff
Tablet
Installer or Admin.
Tablet
Installer or Admin.
Network IP Address
Installer or Admin.
Firmware Version
Installer or Admin.
Tablet
OR Staff
Tablet
OR Staff
Tablet
OR Staff
Tablet
System Shutdown
OR Staff
Tablet
Please consult the user guide for the remote control device connected to MDVR.
Front panel
control keypad
FSN1949 - 01/2016
English - 15
Home Screen
IPS700A
2013-10-20 14:30
Recording
[Current Work]
Video Recording
Status Screens
1. Network IP
192.168.0.1
16 - English
FSN1949 - 01/2016
1. Input Source
Press left or right arrow W X to cycle through source types. Press ENTER to finish.
2. Time Setting
Press ENTER to begin.
Press up or down arrow ST to select the first number of the year, then select ENTER. Continue until the yearmonth-day, and time (24 hr.) settings are complete. Press ENTER to finish.
3. DHCP Setup
Press ENTER to begin.
Press left or right arrow W X to turn DHCP on or off. Press ENTER to finish.
4. Res. Select
Press left or right arrow W X to cycle through input resolutions. Press ENTER to finish.
5. CTRL Device
Press left or right arrow W X to choose between wireless or wired (UART) control device connection. Press
ENTER to finish, the system will reboot.
6. Auto Adjust
Press ENTER to auto adjust analog settings.
7. Analog CSC
Press left or right arrow W X to choose between RGB and YUV settings. Press ENTER to finish.
8. Audio Input
Press left or right arrow W X to choose between Line In and Mic settings. Press ENTER to finish.
9. Pedal Type
Press left or right arrow W X to choose pedal type 1-4. Press ENTER to finish.
Shutdown
System shutdown
Shutdown system
FSN1949 - 01/2016
Press left or right arrow W X to start the shutdown procedure. Press ENTER to proceed with shutdown. To turn
power off, reach behind the MDVR cabinet and turn off the
power switch located on the back panel of the unit.
English - 17
General Specification
Item
Description
Unit
Model
Input
Port
Output
Port
Control key
OSD language
English
Power
Serial communication
Network
Size (H x D x W)
Weight
4.8 / 10.582
mm/(inch)
Kg/Lbs
Input/Output Specification
Item
Signal
Input
Signal
Output
18 - English
Type
Signal Name
Supported Resolution
Application
VIDEO (BNC,SVHS)
CVBS x 1
SVHS(Y/C) x 1
NTSC / PAL
Room Camera,
SD Endoscopy
ANALOG (DSUB15)
DSUB Analog x 1
Up to
1920x1080/60Hz
Endoscopic Camera
DIGITAL (DVI24)
Digital DVID x 1
Up to
1920x1080/60Hz
Endoscopic Camera
VIDEO (BNC)
CVBS x 1
NTSC
Surgical/Diagnostic
Monitor
ANALOG (DSUB15)
DSUB Analog x 1
Up to
1920x1080/60Hz
Surgical/Diagnostic
Monitor
DIGITAL (DVI24)
Digital DVID x 1
Up to
1920x1080/60Hz
Surgical/Diagnostic
Monitor
FSN1949 - 01/2016
FSN1949 - 01/2016
Pin No.
Assignment
Pin No.
Assignment
Red
No Connection
Green
10
Ground-Sync
Blue
11
Ground
Ground
12
DDC Data
DDC 5V Standby
13
H.Sync
Ground-Red
14
V.Sync
Ground-Green
15
DDC Clock
Ground-Blue
Pin No.
Assignment
Pin No.
Assignment
T.M.D.S. Data2
13
No Connection
T.M.D.S. Data2+
14
+5V Power
15
GND
No Connection
16
No Connection
17
T.M.D.S. Data0
DDC Clock
18
T.M.D.S. Data0+
DDC Data
19
No Connection
20
No Connection
T.M.D.S. Data1-
21
No Connection
10
T.M.D.S. Data1+
22
11
23
T.M.D.S. Clock+
12
No Connection
24
T.M.D.S. Clock
Pin No.
Assignment
Composite
Ground
S-VIDEO /Y (Luminance)
S-VIDEO /C (Chrominance)
Ground
English - 19
Input/Output Timing
DVI, VGA input timing
Horizontal
Frequency (KHz)
31.469
31.469
59.941
25.175
31.469
59.940
25.175
37.500
75.000
31.500
35.156
56.250
36.000
37.879
60.317
40.000
48.077
72.188
50.000
46.875
75.000
49.500
48.363
60.004
65.000
60.023
75.029
78.750
54.348
60.053
80.000
67.500
75.000
108.000
45.000
60.000
74.250
60.000
60.000
108.000
63.800
60.000
108.000
79.976
75.025
135.000
Resolution
70.087
25.175
74.077
59.981
130.375
67.500
60.000
148.500
Horizontal
Frequency (KHz)
31.500
60.000
27.000
45.000
60.000
74.250
67.500
60.000
148.500
Resolution
20 - English
FSN1949 - 01/2016
Power Consumption
Mode
Consumption (W)
State
44
Record
35
HDD recording
Normal
32
Standby
Off
Power off
Record
Recording Time
Record Device
Internal disk
Backup Device
USB
Blu-ray
DVD
FSN1949 - 01/2016
Hours
Size
Resolution
45.5
1 Terabyte
1080p
83.3
1 Terabyte
720p
500
1 Terabyte
480p
Hours
Size
Resolution
22 Gbyte
1080p
12 Gbyte
720p
2 Gbyte
480p
1.1
25 Gbyte
1080p
25 Gbyte
720p
12
25 Gbyte
480p
0.15
4.7 Gbyte
1080p
0.3
4.7 Gbyte
720p
2.3
4.7 Gbyte
480p
Source
Surgical camera
Source
Internal disk
English - 21
Mechanical Drawing
80 mm / 3.15 in.
22 - English
FSN1949 - 01/2016
Troubleshooting
Problem
Possible Solution
No power
Check fuse in AC Inlet. If fuse has failed, replaced with similarly rated
new part.
Make sure that the media being used is not write protected.
Verify that there is sufficient space available on the media.
Erase unnecessary files or replace the disc.
Cleaning Instructions
CAUTION:
Do not apply or spray liquid directly on the Video Image Processor chassis as excess liquid may
cause damage to internal electronics. Instead, apply the liquid to the cleaning cloth first.
Note: The Video Image Processor chassis is not disinfected or packed in a sterile environment.
Follow your hospital protocol in case the Video Image Processor chassis needs to be disinfected
prior to installation.
Note: Follow your hospital protocol for the handling of blood and body fluids.
Note: Take care not to damage or scratch the front LCD panel. Be careful with rings or other jewelry that can touch the front filter. Do not apply pressure on the front filter or LCD panel.
1. Clean the exterior of the Video Image Processor chassis using a soft cotton cloth, lightly
moistened with a recognized cleaning product for medical equipment.
2. Repeat with water only.
3. Wipe dry with a dry cloth.
The chassis has been tested for resistance to the following products:
t7JSFY3FBEZUPVTF%JTJOGFDUBOU$MFBOFS
t.JTUZ$MFBS-FNPO%JTJOGFDUBOU
t.JTUZ.VMUJ1VSQPTF%JTJOGFDUBOU$MFBOFS
t.JTUZ.VMUJ1VSQPTF%JTJOGFDUBOU$MFBOFS**
t#PIMFHMBTTDMFBOFS
t;FQ)FBWZEVUZHMBTTBMMTVSGBDFDMFBOFS
t,MFBS4DSFFO
t4DSFFO5'5 ,POUBLU$IFNJF
FSN1949 - 01/2016
t*ODJEJO'PBN &DPMBC
t.JDSP[JE
t.JMEEFUFSHFOU
t*TPQSPQZMBMDIPIPMXJUIDPODFOUSBUJPO
t)PVTFIPMECMFBDI
HFOFSJDTPEJVNIZQPDIMPSJUF
TPMVUJPOTPGTPEJVN
hypochlorite diluted with water between1:10 and 1:100)
t1SFDJTF)PTQJUBM'PBN$MFBOFS%JTJOGFDUBOU
English - 23
FORESEESON GmbH
Industriestrasse 38a, 63150 Heusenstamm, Germany
Tel. +49(0)6104-643980
FORESEESON UK Ltd.
Unit 71, Barwell Business Park
Leatherhead Road, Chessington, Surrey
KT9 2NY, UK Tel. +44-(0)208-546-1047
FORESEESON KOREA
404B, Pangyoinnovalley B, 253 Pangyo-ro, Bundang-gu,
Seongnam-si, Gyeonggi-do, Korea, 463-400
Tel. +82(31)8018-0780 Fax. +82(31)8018-0786
D&T Inc.
Jang-dong, Daedeok Valley, 26-121, Gajeongbuk-ro,
Yuseong-gu, Daejeon, Korea, 305-343
Tel. + 82(42)360-8000 Fax. +82(42)360-8005
Specifications are subject to change with or without notice.
www.fsnmed.com