RA12-75

(12V75Ah)

RA series is a general purpose battery with 10 years design life in float


service. It meets with IEC, JIS and BS standards .With up-dated AGM
valve regulated technology and high purity raw materials, the RA series
battery maintains high consistency for better performance and reliable
standby service life. It is suitable for UPS/EPS, medical equipment,
emergency light and security system applications.

Specification
Cells Per Unit

Voltage Per Unit

12

Capacity

75Ah@10hr-rate to 1.80V per cell @25 oC

Weight

Approx. 23.5 Kg ( Tolerance2%)

Max. Discharge Current

750A (5 sec)

Internal Resistance

Approx. 5.8 m

Operating Temperature Range

Discharge: -20 C ~60 C


Charge: 0 oC~50 oC
Storage: -20 oC~60 oC

Normal Operating Temperature Range

25 oC5 oC

Float charging Voltage

13.6 to 13.8 VDC/unit Average at 25 oC

Recommended Maximum Charging


Current Limit

22.5 A

Equalization and Cycle Service

14.6 to 14.8 VDC/unit Average at 25 oC

Self Discharge

RI TAR Val ve Regul at ed Lead Aci d( VR LA) bat ter ies ca n be st or ed


for mor e than 6 mont hs at 25 oC. Sel f-di sc har ge rat io less than 3%
per mont h at 25 oC. Pl eas e ch ar ge bat ter ies bef or e usi ng.

Terminal

Terminal F11/F15

Container Material

A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
Unit: mm

Dimension: 260(L)169(W)235(H)

Constant Current Discharge Characteristics: A (25 oC)


F.V/Time

5MIN

10MIN

15MIN

30MIN

1HR

2HR

3HR

4HR

5HR

8HR

10HR

20HR

9.60V

2 6 2 .6

1 9 3 .3

1 4 4 .2

7 5 .35

4 6.8 1

2 8.9 0

19 .6 4

1 5 .8 4

1 3 .1 5

8 .6 6

7 .8 0

4 .1 3

10.0V

2 5 5 .0

1 8 4 .0

1 4 1 .3

7 4 .39

4 6.1 9

2 8.3 2

19 .2 8

1 5 .6 1

1 3 .0 3

8 .6 3

7 .7 3

4 .0 5

10.2V

2 4 7 .5

1 7 7 .5

1 3 9 .1

7 3 .25

4 5.7 5

2 8.0 2

19 .1 1

1 5 .4 6

1 2 .9 4

8 .5 5

7 .6 5

3 .9 8

10.5V

2 2 2 .2

1 6 3 .8

1 3 2 .4

7 1 .23

4 5.1 9

2 7.6 5

18 .9 4

1 5 .2 3

1 2 .8 4

8 .4 7

7 .5 8

3 .9 0

10.8V

2 0 0 .6

1 4 9 .3

1 2 2 .0

6 8 .88

4 4.5 6

2 7.4 3

18 .7 2

1 4 .7 1

1 2 .7 7

8 .4 4

7 .5 1

3 .8 6

11.1V

1 7 1 .2

1 3 3 .5

1 0 9 .5

6 6 .26

4 3.5 1

2 6.3 2

18 .3 5

1 4 .5 0

1 2 .6 8

8 .3 7

7 .4 2

3 .7 0

Constant Power Discharge Characteristics: W(25 oC)


F.V/Time

5MIN

10MIN

15MIN

30MIN

1HR

2HR

3HR

4HR

5HR

8HR

10HR

20HR

9.60V

2770

2059

1572

8 6 2.6

5 42 .5

3 38 .7

23 1 .2

1 8 9 .6

1 5 7 .5

1 0 3 .7

9 3 .5 9

4 9 .7 7

10.0V

2716

1996

1547

8 5 3.6

5 37 .5

3 34 .6

22 7 .8

1 8 6 .9

1 5 6 .1

1 0 3 .3

9 2 .8 5

4 8 .9 1

10.2V

2685

1943

1530

8 4 6.2

5 34 .4

3 32 .2

22 6 .8

1 8 5 .2

1 5 5 .1

1 0 2 .5

9 2 .0 3

4 8 .0 0

10.5V

2444

1810

1459

8 2 8.9

5 30 .9

3 28 .0

22 5 .0

1 8 2 .7

1 5 3 .9

1 0 1 .7

9 1 .1 2

4 7 .0 9

10.8V

2226

1668

1349

8 0 9.3

5 24 .1

3 25 .5

22 2 .4

1 7 6 .5

1 5 3 .2

1 0 1 .2

9 0 .2 2

4 6 .6 4

11.1V

1955

1508

1214

7 8 7.1

5 16 .3

3 13 .3

21 8 .7

1 7 4 .0

1 5 2 .6

1 0 0 .5

8 9 .2 4

4 4 .9 7

All mentioned values are average values ( Tolerance2%) .

RA12-75

12V75Ah
Storage characteristic
100

15

Supplementary charge required


(Carry out supplementary charge
before use if 100% capacity is
requires)

Capacity (%)

L ife E xp e cta ncy (years)

12

80
10

Supplementary charge required


before use.
This supplementary charge will help
to recover the capacity and should
be made as early as possible.

60
20

40

30

40

Supplementary charge may often


fail to recover the capacity.
The battery should never be left
standing till this state is reached

20
3

0
2

0
0

10

20

30

40

Supp leme ntar y char ge and stor age


guid elin es

10 12 14 16 18 20 22 24

Storage Time (months)

50

Battery Temperature

Discharge characteristic Curve

Charge characteristic Curve for standby use


15

7.5

5.0

0.24

120

4.7

13

6.5

4.3

12

11

6.0

5.5

80
Discharge
100%0.05CA20h
50%0.05CA10h
Charge
Chcrge Voltage2.275V/C
Charge Current0.1CA
Temperature 25

4.0

3.7

60

40

13

6.5

4.3

12

6.0

4.0

11

5.5

3.7

0.20

100

Chcrge Voltage

0.16

0.12

0.08

Terminal Voltage (V)

7.0

Charge Current (CA)

14

Charge Volume (%)

Charge VoltageV

Chcrge Volume

0.05C
0.16C 0.093C

10

5.0

0.35C

3.3

0.62C
1C

3C

10

5.0

3.3

20

0.04

4.5

3.0

Charge Current

4.5

3.0
0

0.6

1.2

12

30

Charge Timeh

10

20

24

Hr

min

10 12 14 16 18 20 24 28

Discharge Time

Capacity Factors With Different Temperature


Battery Type

-20

-10

10

20

25

30

40

45

GEL
6V&12V
Battery
2V

50%

70%

83%

85%

90%

98%

100%

102%

104%

105%

60%

75%

85%

88%

92%

99%

100%

103%

105%

106%

AGM
6V&12V
Battery
2V

46%

66%

76%

83%

90%

98%

100%

103%

107%

109%

55%

70%

80%

85%

92%

99%

100%

104%

108%

110%

Discharge Current VS. Discharge Voltage


Final Discharge
Voltage V/cell

1.75V

Discharge
Current (A)

A 0.2C

Maintenance & Cautions


1.60V

1.70V
0.2C A 1.0C

A 1.0C

Charge the batteries at least once every six months,


if they are stored at 25 o C.
Charging Method:
Constant Voltage

-0.2Cx2h+2.4-2.45V/cellx24h,Max. Current 0.3C

Constant Current

-0.2Cx2h+0.1Cx 12h

Fast

-0.2Cx2h+0.3Cx4h

Float Service:
Every month, recommend inspection every battery voltage.
Every three months, recommend equalization charge for one time.
Equalization charge method:
Discharge: 100% rate capacity discharge.
Charge: Max. current 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h.
Effect of temperature on float charge voltage: -3mV//Cell.

Bolt

M5

M6

M8

Terminal

F3 F4 F13 F18 T25 T26

F8 F11 F12-1 F15

F5 F9 F10 F12 F14 F16

Torque

6~7N-m

8~10N-m

10~12N-m

Length of service life will be directly affected by the number of discharge


.
cycles, depth of discharge, ambient temperature and charging voltage.

SHENZHEN RITAR POWER CO.,LTD.