Beruflich Dokumente
Kultur Dokumente
Electricity Transmission
designstandard
EDS 50 - 01 Rev. 4
Revision survey
Document title
Document no.
13/90242-7
Target group
Revision
1
2
3
4
Document
status
Approved
Approved
Approved
Approved
Writer
Init
N/A
N/A
xomo
DTR
Reviewer
Date
Init
Date
12.10.09 N/A
12.10.09
10.11.09
10.11.09 N/A
DTR, LBH,
20.11.12
20.11.12
POD, TKL
KKB,LIH,JRM,
08.10.13
07.10.13
IBA,JYL,LBH
Approver
Init
DTR
DTR
Date
10.11.09
10.11.09
DTR
10.01.13
HRI
6.11.13
Revision
Dimension style
Table of contents
1.
Scope
2.
2.1
References
Codes and Standards
5
5
3.
3.1
5
5
4.
Documentation Requirements
4.1 General
4.1.1
Language
4.1.2
Units
4.2 Reports
4.2.1
General
4.2.2
Format
4.2.3
Document numbers & file names
4.2.4
Revisions
4.3 AutoCAD Drawings
4.3.1
CAD systems
4.3.2
Formats and Frames
4.3.3
Scales
4.3.4
Font and text
4.3.5
Title block
4.3.6
Numbering
4.3.7
File names
4.3.8
Revisions
4.3.9
Reference files
4.3.10
Clouds
4.4 Lists
4.4.1
Document list
4.4.2
Cable list
4.5 CADdy++ Drawings
4.5.1
CAD-systems
4.5.2
Standards/Guideline
4.5.3
General
4.5.4
Formats and templates
4.5.5
File names/drawing number
4.5.6
Title block
4.5.7
Components
4.5.8
Terminals
4.5.9
Font and text
4.5.10
Cables
4.5.11
Revision
4.5.12
Clouds
4.5.13
Graphic Lists
4.5.14
Date format
4.5.15
Delivery of Caddy-files
6
6
6
6
6
6
6
7
7
7
7
7
7
8
8
9
9
9
9
9
9
9
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
12
5.
5.1
5.2
12
12
12
Deliverables
Hard Copy
Electronic Documentation
Appendix A:
Appendix B:
Appendix C:
Dimension style
1.
Scope
This Energinet.dk Documentation Standard provides requirements to contents and
layout for Calculations and Reports, Engineering drawings and to Engineering lists for
Electricity Transmission.
This Documentation Standard is one of a set of Standards, comprising all requirements
and guidelines for the preparation of documentation and related issues.
The Standard does not replace the suppliers responsibility for the documentation.
2.
References
2.1
3.
Shall
Should
May
Definitions
5 of 20
4.
Documentation Requirements
4.1
General
The conversion of the drawings and documents shall be sampled tested. The Design
Contractor shall demonstrate to the satisfaction of Energinet.dk that the converted
documents are in accordance with the stipulated requirements listed in said EDS.
All standard templates shall be obtained from Energinet.dk.
For delivery of documentation to Energinet.dk CD-ROM or adequate hard drive shall
be used as data medium. Using another media shall be agreed with Energinet.dk.
4.1.1
Language
The Danish or English language shall be used.
4.1.2
Units
All units to be in S.I. units.
4.2
Reports
4.2.1
General
All Calculations and Reports are to be updated to 'As-Built' and presented as outlined
in this Documentation Standard. Each Calculation or Report is to be presented in a
separate and appropriately marked binder.
4.2.2
Format
Microsoft Word shall be used.
6 of 20
4.2.3
4.2.4
Revisions
Revisions of engineering reports are to be designated as follows:
-
A, B, C, ...
1, 2, 3, ...
4.3
AutoCAD Drawings
Requirements for structure for AutoCAD drawings can be found in appendix A and B.
4.3.1
CAD systems
All drawings shall be delivered in AutoCAD-format (.dwg), converted if required.
CADdy++ can be used for electrical drawings, according to agreement with
Energinet.dk. See section 4.5.
4.3.2
4.3.3
Scales
The following standard metric scales on the drawings shall be used: 1:1, 1:2, 1:5
1:10, 1:20, 1:50, 1:100, 1:200, 1:500, 1:1000 and 1:2000.
7 of 20
4.3.4
4.3.5
Title block
The drawing title block shall contain the following items:
8 of 20
4.3.6
Numbering
The drawing number is to be obtained from Energinet.dk.
4.3.7
File names
All drawings shall be given a drawing number (ref. 4.3.6). The drawing file name
shall be the same as the drawing number.
The file name shall not contain information regarding revisions.
Every drawing file shall only include one view and one layout.
4.3.8
Revisions
Revisions of engineering reports are to be designated as follows:
-
A, B, C, ...
1, 2, 3, ...
4.3.9
Reference files
All, if any, references shall be 'attached' to the drawing when the design phase is
completed. All, if any, references shall be attached to the drawings when the As-Built
documentation is handed over to Energinet.dk.
4.3.10
Clouds
Changes made from one revision to another shall be indicated with clouds on the
drawing. Clouds from older revisions shall be removed when updating to a new
revision.
As-Built revision of the drawings shall not contain any clouds.
4.4
4.4.1
Lists
Document list
An overall document list in Excel format shall be prepared. The list shall as a
minimum contain the following information:
9 of 20
4.4.2
Cable list
A Cable list in Excel format shall be prepared.
The cable numbering shall contain information about the switchboard that the cable
is connected to, ie switch board no. followed by a sequence no.
4.5
CADdy++ Drawings
4.5.1
CAD-systems
Caddy++ V7, V6 and V5 can be used.
4.5.2
Standards/Guideline
Danish standards must be followed. Reference is made to:
EN/DS 61082
Preparation of documents used in electrotechnology.
EN/DS 60617-2 to 11
Graphical symbols for diagrams.
Energinet.dk
Kvikguide (only in Danish)
4.5.3
General
The drawing number, Project description 1, Project description 2 will be issued by
Energinet.dk.
It shall be possible to replace all the templates without losing the information on the
drawing.
4.5.4
4.5.5
4.5.6
Title block
The title block shall consist the following:
Drawing number
Project description 1
Project description 2
Project established date
Supplier's name
Supplier's reference
Designed by
Content of page
(= file name)
(Project station)
(Project switchboard)
(As-built date)
(Not necessary)
(Not necessary)
(Designer)
(Page description 1)
10 of 20
4.5.7
Components
All the components in the switchboard shall be intelligent symbols. It means that the
component shall contain the supplier, type and name. The 'Type database' in
caddy++ must be used.
The text that is according with the components must be intelligent with the
component.
The components shall be to scale 1:1 and frontlayout shall be scale 1:10.
The term of the component shall be agreed with Energinet.dk.
4.5.8
Terminals
Terminal junctions shall be defined correctly in accordance with
the internal/external connection.
4.5.9
4.5.10
Cables
The cables shall be applied as intelligent cables.
The term of the cables shall be agreed with Energinet.dk.
4.5.11
Revision
Revision must be written on each circuit diagram page - date, initials and
description.
As-built versions of the drawings may not contain revision.
4.5.12
Clouds
Changes from one version to the next shall be indicated by clouds on the drawing.
Clouds from previous versions shall be removed when a new version is made.
As-built versions of the drawings may not contain clouds.
4.5.13
Graphic Lists
All lists according to the switchboard shall be generated in the drawing.
4.5.14
Date format
All dates shall be written: YYYY-MM-DD.
11 of 20
4.5.15
Delivery of Caddy-files
The project shall be compressed before handing over to Energinet.dk.
5.
Deliverables
5.1
Hard Copy
Reports:
Drawings:
Lists:
5.2
Electronic Documentation
Reports:
Drawings:
Lists:
12 of 20
Appendix A
Structure of AutoCAD drawings and documents
General drawing
rules
Template
Layer structure
Objects and
blocks
Block/cell hierarchies may not occur, ie blocks and cells may not
contain other blocks/cells.
Standard symbols
The pen setup for the symbols shall comply with Energinet.dks
layer structure.
EN/DS 61082
electro-technology.
EN/DS 60617-2 to 11
Graphical symbols for diagrams.
shall be followed for the symbols!
13 of 20
Dimensioning
Hatching
CAD files
Date formats
Programs
and versions
14 of 20
Comments
white
Yellow
White
Green
Cyan
14
Magenta
White
Green
61
Black
Black
Black
Black
Black
Black
Black
Black
Black
Solid line
Solid line
Solid line
Solid line
Solid line
Solid line
Dash/dot
Dot
Solid line
Yellow
White
Green
Cyan
Yellow
White
Green
Cyan
Black
Black
Black
Black
Dashed
Dashed
Dashed
Dashed
0.18
0.70
0.70
0.70
0.70
2.0
2.5
3.0
3.5
4.5
5.0
4.0
1.25
1.50
1.80
2.5
Magenta
Red
Black
Yellow
Cyan
Yellow
Yellow
White
White
Green
Green
Green
Yellow
Yellow
Yellow
White
Magenta
Red
251
52
Cyan
Yellow
yellow
white
white
green
green
green
60
60
60
white
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Arial
Arial
Arial
Arial
Arial
Arial
Arial
Arial
Arial
Arial
Arial
0.25
Cyan
132
Black
0.35
Blue
blue
Black
style A02-08
2.0
Yellow
yellow
Black
style A03-08
3.0
Yellow
yellow
Black
style
style
style
style
6.0
6.0
9.0
12.0
Green
Green
Green
Green
90
90
90
90
Black
Black
Black
Black
Line thickness
/ text height
Colour on
screen
Colour no.
Continuous
Continuous
Continuous
Continuous
Continuous
Continuous
Continuous
dashdot1
Dot
Continuous
0.25
0.35
0.50
0.70
1.00
0.18
0.35
0.50
0.13
White
Yellow
White
Green
Cyan
Red
Magenta
White
Green
Yellow
Hidden
Hidden
Hidden
Hidden
0.25
0.35
0.50
0.70
Layer no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Text
6
A06
A09
A12
line
line
line
line
Arial (width
0.8)
Arial (width
0.8)
Arial
Arial
Arial
Arial
15 of 20
Line thickness
/ text height
Colour on
screen
Colour no.
Colour
of plot
Comments
6.0
Green
90
Black
Arial (width
0.8)
Continuous / Pline
0.07
Continuous/Hatching 0.18
Red
Magenta
13
magenta
Black
Black
Continuous /
Tone down layer
0.18
Grey
Grey
Frame
Cut marks
0.50
0.18
Green
Magenta
green
magenta
White
yellow
Black
Black
Black
Black
Guide
Blue
150
Black
Ident
Green
13
Black
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
150
150
150
151
151
151
152
152
152
153
153
153
160
160
160
161
161
161
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Layer no.
30
31
32
33
34
35
36
37
38
39
40
42
43
Defpoints
DIM
B018
B018D
B018H
B025
B025D
B025H
B035
B035D
B035H
B050
B050D
B050H
B070
B070D
B070H
B100
B100D
B100H
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.18
0.18
0.18
0.25
0.25
0.25
0.35
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
1.00
1.00
1.00
Block
Block
Layer must
be 'not
plottable'
16 of 20
Layer no.
Line thickness
/ text height
Colour on
screen
Colour no.
Colour
of plot
C018
C018D
C018H
C025
C025D
C025H
C035
C035D
C035H
C050
C050D
C050H
C070
C070D
C070H
C100
C100D
C100H
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.18
0.18
0.18
0.25
0.25
0.25
0.35
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
1.00
1.00
1.00
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
120
120
120
121
121
121
122
122
122
123
123
123
130
130
130
131
131
131
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
Cyan
G018
G018D
G018H
G025
G025D
G025H
G035
G035D
G035H
G050
G050D
G050H
G070
G070D
G070H
G100
G100D
G100H
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.18
0.18
0.18
0.25
0.25
0.25
0.35
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
1.00
1.00
1.00
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
70
70
70
71
71
71
72
72
72
73
73
73
80
80
80
81
81
81
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
M018
M018D
M018H
M025
M025D
M025H
M035
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
0.18
0.18
0.18
0.25
0.25
0.25
0.35
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
200
200
200
201
201
201
202
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Comments
17 of 20
Layer no.
Line thickness
/ text height
Colour on
screen
Colour no.
Colour
of plot
M035D
M035H
M050
M050D
M050H
M070
M070D
M070H
M100
M100D
M100H
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
1.00
1.00
1.00
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
202
202
203
203
203
210
210
210
211
211
211
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
Magenta
R018
R018D
R018H
R025
R025D
R025H
R035
R035D
R035H
R050
R050D
R050H
R070
R070D
R070H
R100
R100D
R100H
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.18
0.18
0.18
0.25
0.25
0.25
0.35
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
1.00
1.00
1.00
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
20
20
20
21
21
21
22
22
22
23
23
23
30
30
30
31
31
31
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Y018
Y018D
Y018H
Y025
Y025D
Y025H
Y035
Y035D
Y035H
Y050
Y050D
Y050H
Y070
Y070D
Y070H
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
Continuous
Dashdot
Hidden
0.18
0.18
0.18
0.25
0.25
0.25
0.35
0.35
0.35
0.50
0.50
0.50
0.70
0.70
0.70
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
40
40
40
41
41
41
42
42
42
43
43
43
50
50
50
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Comments
18 of 20
Layer no.
Line thickness
/ text height
Colour on
screen
Colour no.
Colour
of plot
Y100
Y100D
Y100H
Continuous
Dashdot
Hidden
1.00
1.00
1.00
Yellow
Yellow
Yellow
51
51
51
Yellow
Yellow
Yellow
Comments
19 of 20
Appendix C
Dimension style
20 of 20