Sie sind auf Seite 1von 3

How to measure clinker temperature

at cooler exit
Pyroprocessing

PR PYR P08 44 V1.0

1/3

Introduction
Clinker temperature is measured for cooler efficiency and kiln heat balance analysis.
Measurement of clinker temperature technique must be conducted in a correct manner to obtain
accurate results.

This procedure explains how to measure clinker temperature with minimum error at cooler exit.
To avoid large error in calculation, it is essential to use tools with high precision.
The measurement of the elevation of clinker temperature in an insulated vase.
The measurement of temperatures is made using a thermocouple placed at the center of vase.
The measurement is normally conducted by Process Technicians and Engineers.

Safety aspects
During sample collection, always wear hand glove to handle hot objects and wear goggle to protect from
flying clinker dust.

Clinker sampling and analysis areas must be brightly lighted.


Only sampling points with safe access platforms are to be used.
Personal safety equipment is compulsory.

Prerequisites
Good knowledge on Plant Safety Procedures to ensure safe working environment
Determining the purposes of performing the clinker temperature measurement.
Cross checking the accuracy of clinker temperature
Calculation of sensible heat of clinker at cooler exit for cooler efficiency and heat balance
calculation

To avoid large error in measurement:


It is essential to use tools with high precision. Always use certified and suitable tools such as
thermocouple and electronic thermometers that can measure reading with accuracy of + 0.1 oC

Insert and place the thermocouple at the centre point of the insulated vase.
All rights of reproduction, representation, adaptation and translation relating to this report belong to Lafarge SA. Lafarge SA reserves the right to exploit this
report or not and to freely distribute it to all of its current and future subsidiaries worldwide in any form, whether paper, electronic or digital, including via
internet and/or intranet. This report along with its content is of a confidential nature. In particular, it may not be reproduced, copied, transmitted, published,
divulged and/or appropriated in whole or in part for personal use or for use by a third party without prior consent from the Production & Process Department,
except for reproduction by or for affiliated Lafarge companies.

Procedure Template developed by

How to measure clinker temperature


at cooler exit
Pyroprocessing

PR PYR P08 44 V1.0

2/3

Time frame
The operation must be quick enough from taking clinker sample from the cooler discharge chute and
store it into the insulated vase.

Tools
Certified K-Type thermocouple select thermocouple which has been calibrated and certified fit for use.
When selecting Certified Electronic thermometer with + 0.1 oC accuracy select electronic thermometer
which has been calibrated and certified fit for use. Also use thermometer which can support the type of
thermocouple you use.

Clinker scoop to collect clinker sample


Hand Gloves to handle hot objects
Safety Goggle to protect from flying clinker dust..
Helmet as basic safety working gear.
Protective clothing to protect from hot clinker dust and hot objects.
Walkie talkies for communication with CCR operators.
Small notebook to record measurements.
Special made insulated vase with insulated cover.

Round insulated vase with handle and dimension of internal diameter of xx mm x length
xx mm.

Round insulated cover with a small opening for thermocouple insertion.


Vase and cover to be insulated with 30 mm insulation wool.
Insulated vase to be marked with filling mark.
Filling
mark

Small
opening
for
thermocouple insertion

Thermocouple
measuring point
xx mm
(H)
xx mm

Insulated
Vase

All rights of reproduction, representation, adaptation and translation relating to this report belong to Lafarge SA. Lafarge SA reserves the right to exploit this
report or not and to freely distribute it to all of its current and future subsidiaries worldwide in any form, whether paper, electronic or digital, including via
internet and/or intranet. This report along with its content is of a confidential nature. In particular, it may not be reproduced, copied, transmitted, published,
divulged and/or appropriated in whole or in part for personal use or for use by a third party without prior consent from the Production & Process Department,
except for reproduction by or for affiliated Lafarge companies.

handle

Insulated
cover

Procedure Template developed by

How to measure clinker temperature


at cooler exit
Pyroprocessing

PR PYR P08 44 V1.0

3/3

Action Steps
1.

Clinker Sample collection


Determine a safe location, normally at the clinker discharge chute, where clinker sample can be collected.
SAFETY: Do not collect clinker sample from a moving clinker conveyor.

2.

Prepare for the clinker temperature measurement

Two personnel are required to perform the measurement.


Ensure that the clinker sampling and clinker temperature measurement area are brightly lighted.
Move the insulated vase close to the clinker sampling area.
Set up thermocouple and electronic thermometer. Ensure the probe connector is correctly connected to
the terminal of the thermometer.

Prepare a record check sheet:

3.

Measure the clinker temperature


Before starting, always ensure all SAFETY PRECAUTIONS have been undertaken.
Always keep very close contact with the CCR operator.

Operator A is responsible for taking the reading of temperature.


Operator A places the thermocouple at the centre of the insulated vase.
Operator B takes clinker sample from clinker discharge chute and stores it into the insulated vase.
Operator B continues until it reaches the filling mark of the insulated vase.
Operator B then closes the top cover of the insulated vase.
Operator A waits for the temperature to stabilize and reach equilibrium.
Operator A notes the equilibrium temperature before it begins to decrease.
Record the temperature on a notebook.
Perform several sets of temperature readings to minimize the calculation errors.
The clinker temperature will be the average temperature of the few set of measurements.