Polymerization methods:
1) Standard polymerization:
Immerse the flask into the cold water.
Temper up to 70C within 30 minutes.
Keep the temperature during the next 30 minutes.
Increase the temperature on 100C within 30 minutes.
Keep the temperature for the further 30 minutes.
The total polymerization time is 2 hours.
2) Faster polymerization:
Insert the flask into the cold water.
Temper up to 100C.
Keep the temperature for the next 45 minutes.
3) Fast-boiling polymerization:
Insert the flask into the boiling water (100C).
Keep the temperature for 40 minutes.
This polymerization method is suitable only for partial substitutions max. up to four teeth.
4) Polymerization in a pressure polymerizing apparatus:
Polymerization without flasking, immediately on the model
pressure 0,6 MPa
temperature 100 - 110C
time 10 - 15 minutes
This polymerization method is suitable only for smaller partial dentures and for repairs of dentures.
Safety precautions:
SUPERACRYL PLUS is a highly flammable liquid. The liquid irritates the eyes, respiratory system and skin,
and may cause sensitisation upon contact with the skin. In case of accidental contact wash the skin with water
and soap. After contact with eyes, rinse immediately with plenty of water and seek medical advice.
Waste material disposal:
Dispose of unused powder and its packaging with ordinary worksite waste. Residues of unused liquid should be
transferred to a company authorized to dispose of waste materials or dispose of it in an incineration plant for
dangerous waste. Do not pour the liquid into the public sewage system.
Storage:
Store in a dry and dark place at 5 C to 25 C, in a well sealed container. Store the package in a well ventilated
area, away from heat sources. Smoking is prohibited.
Shelf-life:
4 years
Packaging:
powder: 500 g
liquid: 250 g
Set
powder: 300 g
liquid: 150 g