Beruflich Dokumente
Kultur Dokumente
WELL CONTROL
Well Control
IPM
Hydrostatic Pressure
In which vessel is the hydrostatic pressure the highest
Well Control
IPM
Hydrostatic Pressure
IPM
Hydrostatic Pressure
6240 psi
7800 psi
5616 psi
Well Control
IPM
6058 psi
Hydrostatic Pressure
5616 psi
6240 psi
IPM
6000 psi
Well Control
6000 psi
Causes of Kicks
There are 5 major causes of kicks
1.
2.
3.
4.
5.
Well Control
IPM
Kick Detection
A kick cannot occur without a warning sign or variations with return flow
Well Control
IPM
Also consider
Drilling BREAKS
Decrease in pump pressure
Increase in pump strokes
Change in drilling fluid properties
Well Control
IPM
Well Control
IPM
Flow Checks
Involves physically checking the level of fluid in the annulus
Flow check are to be done
Well Control
IPM
Kick Containment
The size and severity of a kick depends upon
the degree of underbalance
the formation permeability
the length of time the well remains underbalanced
Any suspected kick should be shut in as fast as possible
Well Control
IPM
Shut in Procedures
Well Control
IPM
BOP Equipment
Consists of 4 main components
1. The BOP stack
2. The accumulator unit
3. The choke manifold
4. The kill line
Well Control
IPM
BOP Stack
The BOP stack is located over the well head and under drill floor in surface BOPs
They might include
Annular preventer
Pipe ram preventer
Drilling spool
Blind/shear ram preventer
Casing head housing
The stack is assembled in many arrangements depending upon requirements
Well Control
IPM
BOP Stack
Well Control
IPM
Annular Preventer
Are available in different sizes, makes and pressure ratings
All contain a steel reinforced rubber packing that close around tubulars
Well Control
IPM
Ram Preventers
Ram preventers close on the drill pipe by moving rams from a retracted position
They operate in pairs and seal the space below them when closed
They have openings that match the diameter of pipe for which they are designed
Also come in different sizes, makes and pressure ratings
Well Control
IPM
Ram Preventers
Well Control
IPM
Accumulator
Well Control
IPM
Accumulator Bottle
Bladder Assembly
Shell
Fluid Port Assembly
Well Control
IPM
Accumulator Sizing
3000 psi
Accumulator
Fluid
1000 psi
Non-Flammable Gas
PRECHARGE
VOLUME AT
ACCUMULATOR
OPERATING PRESS
1200 psi
USABLE
VOLUME
IPM
SPECIFICATION:
Accumulator Sizing
SLB STANDARD
ANNULAR
TOP RAMS
Close all (rams and annular) functions and Open all HCRs valves
Open all (rams and annular) functions and Close all HCRs valves
Close Annular
Open choke line remote operated valve
IPM
BOTTOM RAMS
BOTTOM RAMS
Well Control
BLIND RAMS
Accumulator Sizing
3000 psi
Accumulator
Fluid
Non-Flammable Gas
1000 psi
1200 psi
USABLE
VOLUME
Operating
Useable
Pressure
1000
3000
1200
Gas Vol
10
3.33
8.33
PxV
10,000
10,000
10,000
6.67
1.67
Liquid Vol
Well Control
IPM
UV = 6.67 1.67
UV = 5
Accumulator Sizing
SLB STANDARD
EXAMPLE:
BOP Equipment:
1 Annular + 3 Rams + HCR Valve
Closing Volume (CV):
20
+ (3 x 10) + 1 = 56 Gal
Opening Volume (OV):
20
+ (3 x 10) + 1 = 56 Gal
Closing Volume (CV):
20
= 20 Gal
Open Choke Line Valve (OV):
1
= 1 Gal
Usable Volume (UV):
= 133 Gal
Nominal (Bottle) Volume (NV): 2 x UV
Well Control
IPM
= 266 Gal
Choke Manifold
- An assembly of HP flanged fittings
- Several lateral outlets
- Attached to the BOP stack with choke line
- Choke helps to maintain back pressure
- This prevents further influx
- The fluid from well can be diverted
Well Control
IPM
Choke Manifold
11
12
10
Well Control
IPM
13
Inside BOP
Kelly Cock or FOSV
Well Control
IPM
Inside BOP
Gray Valve
Well Control
IPM
Float Valves
SPECIFICATION:
Float valves must be used while drilling and opening hole prior to setting
surface casing or any time the posted well control plan is to divert and can
also be used in deeper sections of the hole. They:
Well Control
IPM
GAS
Baffle Plates
From Choke
MUD
Mud
Drain Line
w/Valve
Well Control
IPM
Impingement
Plate
d
Siphon Breaker
No Valves!!
No Valves!!
Well Control
IPM
Kill Line
Attached to the BOP stack
Usually directly opposite choke line
Used to pump fluid into the annulus to either
keep hole full during losses
to keep balance with heavy mud
Well Control
IPM
BOP Test
11
12
13
To Poor Boy
8
To manifold
10
- Close Annular
- Open Dowell valve
- Close Kill Line inside valve, close Choke Line Middle valve and pressure
test
- Reopen Kill Line inside valve, reopen Choke Line Middle valve
IPM
8 - 11 - 12 - 13
1 - 2 - 3 - 4 - 5 - 6 - 7 - 9 - 10
CLOSED
OPEN
5 - 7 - 9 - 10 - 12
1 - 2 - 3 - 4 - 6 - 8 - 11 - 13
CLOSED
OPEN
6-1-4
2 - 3 - 5 - 7 - 8 - 9- 10 - 11 - 12 - 13
CLOSED
OPEN
2-3-6
1 - 4 - 5 - 7 - 8 - 9- 10 - 11 - 12 - 13
CLOSED
OPEN
- Close Kill Line outside valve, Close HCR valve and pressure test
- Reopen kill Line outside valve, Reopen HCR valve
- Reopen Annular
- Close pipe ram and pressure test
Well Control
All pressure tests 500 psi low, 1000 psi high, 5 minutes
Valves 1 and 4 on choke manifold only to 500 psi
Testing BOPs
Choke
Manifold
ANNULAR
15
TOP RAMS
10
Kill Line
2
BLIND RAMS
Wellhead
Well Control
IPM
11
12
14
BOTTOM RAMS
BOTTOM RAMS
Test Pump
13
Testing BOPs
Wellhead
Well Control
IPM
Testing BOP
Plug Type Tester
Well Control
IPM
Testing BOPs
Choke
Manifold
ANNULAR
15
TOP RAMS
10
Kill Line
2
BLIND RAMS
Wellhead
Well Control
IPM
11
12
14
BOTTOM RAMS
BOTTOM RAMS
Test Pump
13
Testing BOPs
Choke
Manifold
ANNULAR
15
TOP RAMS
10
Kill Line
2
BLIND RAMS
Wellhead
Well Control
IPM
11
12
14
BOTTOM RAMS
BOTTOM RAMS
Test Pump
13
Testing BOPs
Cup Type Tester
Well Control
IPM