Sie sind auf Seite 1von 4

Contractor:

Project Title:

Client:

Abadan New Pump Stations & Terminals Complex


And Mile 40 Pump Station
Doc. Title: Data Sheet For Flame Arrestor
TB No.
Client No:

N.I.O.E.C

Unit
Code
208

Prj
1120

Phase

.Dis

EB

PI

Doc
Type
DS

Serial
.No
5002

Rev.
.No
A2

Sheet No.
1 of 3

DATA SHEET FOR FLAME ARRESTOR

ISSUED FOR
REVIEW
APPROVAL
INFORMATION

A4
A3
APPROVED
FOR DESIGN
REVISED AS
PER CLIENTS
COMMENTS

R.J.N

M.H.M

R.K

R.J.N

M.H.M

R.K

88/02/12

FIRST ISSUE

Date

Description

R.J.N
Prepared By

M.H.M
Checked By
Contractor

R.K
Approved By

A2

88/05/05

A1

88/04/03

A0
Rev.

Approved By
Client

Date

Contractor:

Project Title:

Client:

Abadan New Pump Stations & Terminals Complex


And Mile 40 Pump Station
Doc. Title: Data Sheet For Flame Arrestor
TB No.
Client No:

N.I.O.E.C

Unit
Code
208

Prj
1120

Phase

.Dis

EB

PI

Doc
Type
DS

Serial
.No
5002

Rev.
.No
A2

Sheet No.
2 of 3

A1

A2

X
X

X
X

21

41

X
X

22

42

23

43

24

44

25

45

26

46

27

47

28

48

29

49

10

30

50

11

31

51

12

32

52

13

33

53

14

34

54

15

35

55

16

36

56

17

37

57

18

38

58

19

39

59

A4

A5

A0

A1

A2

A3

A4

A5

Page

A0

A3

Page

Page

Document Revision Index


A0

A1

A2

A3

A4

A5

Contractor:

Project Title:

Client:

Abadan New Pump Stations & Terminals Complex


And Mile 40 Pump Station
Doc. Title: Data Sheet For Flame Arrestor
TB No.
Client No:

Prj
1120

N.I.O.E.C

Unit
Code
208

20

Phase

.Dis

EB

PI

Doc
Type
DS

Serial
.No
5002

40

Rev.
.No
A2

Sheet No.
3 of 3

60

FLAME ARRESTOR DATA SHEET


1

Applicable To: PURCHASE

For: NIOEC

Unit: 208

Site:

ABADAN NEW PUMP STATIONS & TERMINALS


COMPLEX AND MILE 40 PUMP STATION

No. Required : ONE

Manufacturer:

Model:
TECHNICAL DATA

Item No.: FA-0006

Connections : FLANGED TYPE ( 2, 150# , WN , RF )

6
7

Type : [ ] INLINE [X] VENT [X] VRTICAL

-Size : 2 NPS

Material

-Rating : 150 LBS

-Housing : CARBON STEEL

Painting : REQD

-Elements: STAINLESS STEEL

Special Requirements : -

8
9

AS PER PROJECT PAITING SPECIFICATION

PROCESS DATA
10 Media : PRODUCT VAPOR
11 Flow Rate
12 -Maximum : -

Inlet Pressure

13 -Normal : 5.0 M3/HR


14 Temperature
15 -Maximum : -

Specific Gravity : 0.885


Does the Stream Have Liquids? NO

16 -Normal : AMBIENT

Flash Point: - 5 OC

-Maximum : -Normal : ATM.

Desired Pressure Drop: MINIMUM

17 IEC Gas Grouping : II B


19 Distance of Installation From Potential Flame Source: MORE THAN 10 METERS
20
21

Contractor:

Project Title:

Client:

Abadan New Pump Stations & Terminals Complex


And Mile 40 Pump Station
Doc. Title: Data Sheet For Flame Arrestor
TB No.
Client No:

Prj
1120

N.I.O.E.C

Unit
Code
208

Phase

.Dis

EB

PI

Doc
Type
DS

Serial
.No
5002

Rev.
.No
A2

22
Remarks:
1. Arrestor vendor shall submit full technical details about following in technical vendor document:
a)Performance b)Construction material
c)Accessories
d)Fabrication codes & standards e)Inspection and test

Sheet No.
4 of 3