Sie sind auf Seite 1von 5

Arrancador directo

Tipo de dispositivo de proteccin de cortocircuito


Intensidad de corto circuito Iq (kA)
Tipo de coodinacin
Potencia nominal 400V 50Hz AC3 (kW)
Intensidad de empleo nominal Ie - 400V - AC3
(A)

Con fusible
80.0
2
4.0
8.5

Contactor
A9-30-10

1SBL141001R8010

Rel trmico de sobrecarga


TA25DU11

As part of its on-going improvement,


ABB reserves the right to modify the characteristics
or the products described in the following document.
The information given is not-contractual.
For further details, please contact the ABB company marketing
of these products in your country.

1SAZ211201R1043

Direct-On-Line and Reversing Starters


Open Type Version, in Kit Form
Protected by Thermal Overload Relay
A9 ... A110
BER, BEM
A9 ... A110

A9 ... A110

TA .. DU

TA .. DU

Direct-On-Line Starters
3-pole a.c. operated contactors
A 9

A 12

A 16

A 26

A 30

A 40

TA 25 DU
0.1 ... 0.16 A to 24 ... 32 A
Thermal overload relays

A 50

A 63

A 75

TA 75 DU
18 ... 25 A to 60 ... 80 A

A 95

A 110

TA 80 DU
29 ... 42 A to 60 ... 80 A

TA 42 DU

TA 110 DU

18 ... 25 A to 29 ... 42 A

65 ... 90 A to 80 ... 110 A

A 30

A 95

Reversing Starters
3-pole a.c. operated contactors
A 9

A 12

A 16

A 26

A 40

A 50

A 63

A 75

A 110

Connection sets
BER 16V (1)

BER 40V (1)

BEM 75-30

BEM 110-30

TA 25 DU
0.1 ... 0.16 A to 24 ... 32 A

TA 75 DU

TA 80 DU

Thermal overload relays


18 ... 25 A to 60 ... 80 A

29 ... 42 A to 60 ... 80 A

TA 42 DU

TA 110 DU

18 ... 25 A to 29 ... 42 A

65 ... 90 A to 80 ... 110 A

Mechanical / electrical interlock units


VM 5-1 / VE 5-1

VE 5-2

(1) If only an electrical interlocking is required between contactors A 9 up to A 40, use BER 16 and BER 40 connection sets for contactors with N.C. built-in auxiliary contacts.

34
1SBC101001C0202

Direct-On-Line and Reversing Starters


Open Type Version, in Kit Form
Protected by Thermal Overload Relay
Application
Direct-on-line and reversing starters for controlling three-phase asynchronous motors:
- for a maximum operational voltage up to 690 V - 50 or 60Hz
- for a switching frequency of < 15 starts an hour with a load factor of 80 %

of < 30 starts an hour with a load factor of 50 %
- with an ambient temperature near the devices of < 55 C

Coordination
See "Online Product Selection Tools" on "www.abb.com/lowvoltages" website.
Click on "Online Selected Optimized Coordinations" to display the required coordination table according to the short-circuit protection device
and the coordination type complying with IEC/EN 60947-4-1.

Mounting and Connection Accessory Description


BER or BEM connection sets allow to assemble quickly reversing starters. These accessories eliminate the potential risk of wiring errors, reduce
the time required to install and to maintain reversing starters.
For the reversing contactors the interlocking can be easily assured by a simple mounting between both contactors of:
- a VE 5-.. interlock unit for a mechanical and electrical interlocking
- a VM 5-1 interlock unit for a mechanical interlocking and add-on N.C. aux. contacts for the electrical interlocking (or use contactors with built-in N.C. aux. contacts).
Nota: If only an electrical interlocking is required between 3-pole contactors A 9 up to A 40, select contactors with add-on or built-in N.C. auxiliary contacts associated with BER 16 and
BER 40 connection sets (A 9-30-01 ... A 40-30-01 contactors, see main catalogue).

Direct-On-Line Starters - Selection and Ordering Details Reversing Starters - Selection and Ordering Details
(for coil voltage codes and overload relay ranges, see pages 0/1 and 0/2 in the cover flap)

Contactor KM1
Type

(for coil voltage codes and overload relay ranges, see pages 0/1 and 0/2 in the cover flap)

Rated
Power

AC-3
kW

Thermal Overload Relay


Type

Interlock
Unit

Connection
Set

state coil voltage

Type

Type

A 9-30-10

1SBL 141 001 R

10

TA 25 DU

1SAZ 211 201 R10

2 x A 9-30-10
1SBL 141 001 R

TA 25 DU

10 1SAZ 211 201 R10

VE 5-1

BER 16V

5.5

A 12-30-10

1SBL 161 001 R

10

TA 25 DU

1SAZ 211 201 R10

5.5

2 x A 12-30-10
1SBL 161 001 R

TA 25 DU

10 1SAZ 211 201 R10

VE 5-1

BER 16V

7.5

A 16-30-10

1SBL 181 001 R

10

TA 25 DU

1SAZ 211 201 R10

7.5

2 x A 16-30-10
1SBL 181 001 R

TA 25 DU

10 1SAZ 211 201 R10

VE 5-1

BER 16V

11

A 26-30-10

1SBL 241 001 R

10

TA 25 DU

1SAZ 211 201 R10

11

2 x A 26-30-10
1SBL 241 001 R

TA 25 DU

10 1SAZ 211 201 R10

VE 5-1

BER 40V

15

A 30-30-10

1SBL 281 001 R

10

TA 25 DU

1SAZ 211 201 R10

15

2 x A 30-30-10
1SBL 281 001 R

TA 25 DU

10 1SAZ 211 201 R10

VE 5-1

BER 40V

18.5

A 40-30-10

1SBL 321 001 R

TA 42 DU

1SAZ 311 201 R10

18.5

2 x A 40-30-10
1SBL 321 001 R

TA 42 DU

10 1SAZ 311 201 R10

VE 5-1

BER 40V

10

22

A 50-30-00

1SBL 351 001 R

TA 75 DU

1SAZ 321 201 R10

22

2 x A 50-30-00
1SBL 351 001 R

TA 75 DU

00 1SAZ 321 201 R10

VE 5-2

BEM 75-30

00

30

A 63-30-00

1SBL 371 001 R

TA 75 DU

1SAZ 321 201 R10

30

2 x A 63-30-00
1SBL 371 001 R

TA 75 DU

00 1SAZ 321 201 R10

VE 5-2

BEM 75-30

00

37

A 75-30-00

1SBL 411 001 R

TA 75 DU

1SAZ 321 201 R10

37

2 x A 75-30-00
1SBL 411 001 R

TA 75 DU

00 1SAZ 321 201 R10

VE 5-2

BEM 75-30

00

45

A 95-30-00

1SFL 431 001 R

TA 110 DU

1SAZ 411 201 R10

45

2 x A 95-30-00
1SFL 431 001 R

BEM 110-30

00

TA 110 DU

1SAZ 411 201 R10

VE 5-2

00

55

A 110-30-00

1SFL 451 001 R

TA 110 DU

1SAZ 411 201 R10

55

2 x A 110-30-00
1SFL 451 001 R


00

TA 110 DU

1SAZ 411 201 R10

VE 5-2

BEM 110-30

00

state coil voltage code

state max. setting range

Order Code

Rated
Power

Order Code

state setting range code

AC-3
kW

Contactors KM1 + KM2


Type

Thermal Overload Relay


Type

state coil voltage

state max. setting range

Order Code

Order Code

state coil voltage code

state setting range code

Ordering Details - Main Accessories


Description
Type

Order Code

Packing
pieces

Mechanical interlock unit

VM 5-1

1SBN 030 100 R1000

0.066

Mechanical & electrical interlock units

VE 5-1

1SBN 030 110 R1000

0.076

VE 5-2

1SBN 030 210 R1000

0.146

Connection sets

BER 16V

1SBN 081 411 R1000

0.045

BER 40V

1SBN 082 411 R1000

0.085

BEM 75-30

1SBN 083 501 R1000

0.243

BEM 110-30

1SFN 084 301 R1000

0.450

>> Other accessories, ordering details.............................................................. page 57

Weight
kg

>> Other contactor and thermal overload relay types....................... Main Catalogue

35
1SBC101001C0202

Direct-On-Line Starters
Open Type Version in Kit Form
Protection by Thermal Overload Relay

KM1

40
1SBC101001C0202

96

13

KM1

A1

A1

14

14

KM1

Remote Control

Local Control

KM1
E3034D

Us
N
KM1 : 3/L2

A2

KM1
E2861D

Us
N
KM1 : 3/L2

A2

E2858D

6/T3

4/T2

2/T1

98

96

U1 V1 W1

13

FR1

Power Circuit

FR1

96

14

6/ T3

4/ T2

2/ T1

A2
R

97

FR1

95

95

KM1 : 5/L3
Us

95

5/ L3

A1

KM1 : 5/L3
Us

13

3/ L2

1/ L1

Wiring Diagrams for Direct-On-Line Starters

A 9 ... A 16 3-pole Contactors


Protected by Thermal Overload Relay
Direct-On-Line and Reversing Starters
Dimensions (in mm)

133

35

4.5
(M4)

60

50

74

35 mm EN/IEC 60715

74

10

E0759D

4.5

4.5

E0101D

44

95

A 9, A 12, A 16
+ TA 25 DU thermal O/L relay

E0760D

14*

75
68

E2866D

4.5

60

50

35 mm EN/IEC 60715

134

4.5
(M4)

12

5.5

35

59

4.5

A 9, A 12, A 16
+ VM 5-1/VE 5-1 interlock unit
+ BER 16V connection set
+ TA 25 DU thermal O/L relay

95

E2867D

14*

75
68

95

A 9, A 12, A 16
+ BER 16 connection set
+ TA 25 DU thermal O/L relay
* For TA 25 DU 32 only

46
1SBC101001C0202

E2869D

1
14*

E2868D

4.5

60

50

35 mm EN/IEC 60715

134

4.5
(M4)

12

5.5

35

44

4.5

E2870D

88

E0110D1

103

Das könnte Ihnen auch gefallen