WARNING
Introduction
Purpose
This field service bulletin provides the instructions necessary to replace the power supply control board in an HPR130,
HPR260, HPR130XD, or HPR260XD power supply.
Description
041993
229386
Quantity
1
1
Jumpers
The jumpers on the new control board must match the jumpers present on the old control board. Configure the jumpers
on the new control board to match the jumpers on the old control board in the corresponding locations. See the figure
below for jumper locations.
= HPR130
HPR130XD
= HPR260
HPR260XD
041993
PR130
=H
HPR130XD
= HPR260
HPR260XD
Power supply
control board
PCB shelf
Location of J2
45
PCB
mounting
screw
removed
Empty
header
on J2
Wire is in position 7
LED
Signal name
Notes
D100
D101
D113
D114
D117
D118
+5 VDC
+3.3 VDC
CAN TX
CAN RX
RS-422 TX
RS-422 RX
Constant blinking
Constant blinking
Notes
LED
Item
Part number
U104
U105
081169 EVEN
081169 ODD
041993
LED
D321
D322
D323
D324
D325
D326
D327
D328
D329
D330
Not used
Hold
Pierce
Corner current
Plasma start
D331
D332
D333
D334
D335
D336
D337
Notes
HV transformer
Pump motor enable
Contactor
Pilot arc relay
Spare
Surge select
Phase loss