Beruflich Dokumente
Kultur Dokumente
HS26-060-1P
GCS16-090-350-2Y
-14
-21
-26
-31
-41
-46
-51
-65
-81
BTU = TONS
= 1 ton
= 1 tons
= 2 tons
= 2 tons
= 3 tons
= 3 tons
= 4 tons
= 5 tons
= 6 tons
BTU = TONS
-95 = 7 tons
-135 = 10 tons
-185 = 15 tons
-275 = 20 tons
-300 = 25 tons
-360 = 30 tons
-415 = 33 tons
-450 = 37 tons
-600 = 50 tons
New Nomenclature
BTU = TONS
012 = 1 ton
018 = 1-1/2 tons
024 = 2 tons
030 = 2-1/2 tons
036 = 3 tons
042 = 3-1/2 tons
048 = 4 tons
060 = 5 tons
072 = 6 tons
BTU = TONS
090 = 7 1/2 tons
120 = 10 tons
150 = 12-1/2 tons
180 = 15 tons
240 = 20 tons
300 = 25 tons
360 = 30 tons
450 = 37-1/2 tons
540 = 45 tons
Voltage Code
Since 1968 all Lennox equipment that operates on voltage
other than 120-volt/60 hertz single phase, is labeled with a
letter designation to indicate primary voltage. This designation
is the last letter in the unit model number.
GCS16-060-125-2P - P =, single phase & 60 hertz.
VOLTAGE CHARACTERISTICS
Code
Voltage
Phase
Hertz
Letter
A
230
1
60
B
208
1
60
C
230/240
1
60
D
208/220
3
60
E
220/240
3
60
F
440/480
3
60
G
460
3
60
H
550/600
3
60
J
575
3
60
K
208/230
1
50
L
208/240
3
60
M
380/420
3
50
N
220/240
3
50
P
208/230
1
60
Q
230
3
60
R
208
3
60
S
550
3
60
T
220/240
1
50
U
208/240
1
60
W
200/220
1
50
X
277
1
60
Y
208/230
3
60
Serial Numbering System
Description
Gas heating unit, series 14, 100,000 Btuh
G14-100
input.
Gas heating unit, series 14, direct drive
G14Q3-80
blower for 3 tons of cooling, 80,000 Btuh
input.
Gas heating unit, series 12 direct drive
G12Q3E-110
blower for 3 tons of cooling electronic
ignition, 110,000 Btuh input.
Condensing unit, series 18, approximately
HS18-261-7P 26,000 cooling capacity (2 tons), single
phase power.
Condensing unit, series 19, approximately
HS19-311-1P 31,000 Btuh cooling capacity (2-1/2 tons),
single-phase power, expansion valve unit.
Heat pump unit, series 19, approximately
51,000 Btuh heating and cooling capacity (4
HP19-511-1Y
tons), three phase power, expansion valve
unit.
Evaporator coil, up-up-flow, series 16,
C16-41-1FF
approximately 41,000 Btuh cooling capacity
(3 tons).
Single package air conditioner, series 15,
CHA15-261-1P approximately 26,000 Btuh cooling capacity
(2 tons), single-phase power.
Letter Codes
Code
Explanation
Blower
*D
DF
Down Flow
DFV
Filter box
G**M
G**MP
G**V
G**MPV
GHR
GSR
OF
OHR
Code
OS
*Q
Explanation
Oil furnace horizontal
Direct drive blower, generally for both heating and cooling
AF
Adapter frame
AC
AM
BMAC
CB
CBH
CBS
CBW
CBX**M
CBX**MV
CH
COWB
CP
CR
DX
Electric furnace
ED
FF
GSB
Heating module-hydronic
HRV
HP
HPXA
HPW
HS
HSXA
HSM
HSMW
HSA
HW
IK
Installation kit
LD
LF
LP
MGF
Code
Explanation
MV
PCO
PG
PV
Power vented
OF
RA
RD
RP
Readout panel
RGF
RT
Duct enclosure
SC
Solar collector
SE
SG
SO
SU
Storage unit
TC
UGF
UH
Up flow horizontal
UHG
UV
UVO
UHI
WB
WD
WP
Powered humidifier
WS
ZD
ZM
CBH
CHA
CHP
Single package heat pump (indoor & outdoor coils and blower in
same unit)
CPH
CMZ
DMS
DSS
LGA
LGB
LGC
LGE
L Series package gas unit with cooling for Wal Mart meets 90.1
LCA
LCB
L Series package cooling with add on electric heat for Wal Mart
LCC
Code
Explanation
LCE
L Series package cooling with add on electric Wal Mart meets 90.1
LHA
EAC
ECB
ECH
ERS
ERV
ERW
FMP
GCS
GED
GEDH
HSW
HRW
LLB
LSC
LSA
LSA***P
LSM
LHF, LMU, Gas fired rooftop systems (heating, make-up air, ventilating)
LHV
LUF
OAD
OCS
OHP
Oil burner
PCW
PCE
RMF
RTM
RVZ
SMS
SHP
ZDB
HSWC
LRDG
LRDV
MCHA
MCHP
REMD
EMDH
Note: Revision level will appear in the revision block below the model number
on Nameplates. Bill of Material spreadsheets will show the revision level at the
end of the model number.
Coil Blowers
Note: Revision level will appear in the revision block below the model number
on Nameplates. Bill of Material spreadsheets will show the revision level at the
end of the model number.
Note: Revision level will appear in the revision block below the model number
on Nameplates. Bill of Material spreadsheets will show the revision level at the
end of the model number.
156 = 13 Tons
A0 = Novar 2051
180 = 15 Tons
210 = 17.5 Tons
240 = 20 Tons
300 = 25 Tons
360 = 30 Tons
420 = 35 Tons
480 = 40 Tons
Coil Options
540 = 45 Tons
0 = No Option
600 = 50 Tons
A = Outdoor Only
660 = 55 Tons
B = Indoor Only
720 = 60 Tons
Cooling Efficiency
S = Standard Efficiency
M = Mid Efficiency
Heat-X Option
0 = Standard
1 = Stainless Steel
H = High Efficiency
U = Ultra High Efficiency
Heating Option
Exhaust Option
0 = No Option
1 = Gravity Exhaust (Barometric Relief)
2 = Power Exhaust Fan, CV Prop
3 = Power Exhaust Fan, VAV Prop.
4 = PEF, CV Centrifugal
C = 10 KW Electric Heat
D = 15 KW Electric Heat
6 = Future options
E = 20 KW Electric Heat
F = 25 KW Electric Heat
G = 30 KW Electric Heat
0 = No Option
J = 45 KW Electric Heat
K = 60 KW Electric Heat
P = 90 KW Electric Heat
Refrigerant Type
2 = R-22
4 = R-410A
Electrical Option
Blower Type
D = Constant Volume Direct Drive
E = Variable Volume Direct Drive
0 = No Option
1 = Disconnect
2 = HACR Breaker
Coil Blowers
L Series