Sie sind auf Seite 1von 1

represented by:

measurIT technologies

Flow Measurement in a Sewage Treatment Plant


Precise non-invasive measurement. Cost advantage as compared with MIDs since independent of the
nominal diameter; easy installation; dual-channel transmitter. Ideal for upgrading plants.

Measuring task Method Medium

? Flow measurement Ultrasound Wastewater

Features Measuring task……………………………………….


Medium: raw sewage with recycled In sewage treatment plants, undesired components are removed
sludge and nitrified wastewater from the wastewater by means of mechanical, biological and
Pipes: DN1200 and DN1400 chemical procedures. After the larger, undissolved impurities have
been mechanically removed with the rake and by means of
Material: stainless steel sedimentation in the sand trap and in the primary settling tank, the
9 measuring points for multi-beam biological treatment follows. Bacteria and other micro-organisms are
measurements, with 9 FLUXUS? used to mineralize biodegradable organic wastewater components
ADM 7407 (2 channel) units and 18 as far as possible. Organically bound nitrogen is removed in
sets of M2N7 transducers. denitrification tanks.
In the course of expanding a municipal sewage treatment plant, flow
measurements were required at six new denitrification tanks.

Solution……………………………………………….
Non-invasive ultrasonic flow measurement is a very good and
economic alternative to the magnetic-inductive flowmeters
customarily used in the water and wastewater industry. Because the
clamp-on ultrasonic transducers are simply installed on the outer
surface of the pipe, large diameters do not imply any significant
additional costs. Furthermore installation and commissioning are
very easy, requiring no pipework or large construction work.
The measuring points are at the inlets of the denitrification tanks
(with recycled sludge) and at the recirculation pipes. The high
transmission power of the FLUXUS? ADM ensures reliable and
failure safe measurements even in the case of large diameters,
deposits and/or contamination of the wastewater with solid sludge
Easy installation without pipework or particles. Using dual-channel transmitters makes it possible to set
construction: The clamp-on transducers are
simply attached to the outside of the pipe. up each measuring point for cross-measurements with two pairs of
transducers.

Advantages…………………………………………….
Reliable and safe measurement
A high dynamic measuring range ensures precise measurements
at both low and high flow rates.
Highly precise and stable measurements thanks to the cross-
measurement set-up with two sensor pairs and a dual-channel
transmitter at each measuring point.
Enormous cost advantage as compared with magnetic inductive
flowmeters
Ultrasonic dual-channel FLUXUS? ADM 7207 Easy, cost-efficient installation (no crane and heavy equipment
transmitter reliably monitors the measuring required for assembly)
points.
Not disturbed by deposits