Sie sind auf Seite 1von 1

represented by:

measurIT technologies

Measuring Task Flow Measurement


Flow measurement of the water exchange between water towers or of Drinking Water
elevated service reservoirs in the supply network.
Piping DN 250 to DN 500 Customer

Instruments Used
8 FLUXUS® ADM 7207, one and two channel with transducers M2N7 and
K2N7for a total of 12 measuring sites

Advantages
• Upgrading the existing installation made simple by the clamp-on Niederrheinische Versorgung
technique; no need to cut the existing piping und Verkehr AG,
Mönchengladbach
• High accuracy even at low flow velocities
• Highly adaptable to future changes in the facility installations NVV AG is the municipal trans-
portation, public utilities and waste
Selling Points management company for the
Niederrhein (Lower Rhein) region.
• Cost advantage over comparable measuring systems (for ex. MID) It supplies a quarter of a million
with the same compatibility of nominal widths
people in and around Mönchen-
• Low running costs due to the practically maintenance-free system gladbach with drinking water.
• Considerable cost advantage through simple upgrade without
changing the piping

Description
The NVV AG operates six water works in their drinking water supply area
with a delivery rate of 3 500 m³/h and four storage tanks with a capacity of
10 100 m³. The estimated maximum hourly consumption is 4 340 m³ and
Modern technology rejuvenates a historic building -
daily consumption is 6 2000 m³. The supply area is divided into two the water tower built in 1908, a historical preservation
pressure zones. Drinking water can be exchanged between the two site, in the Viersener Straße
pressure zones through gate valves and pumps.
In the past, the only flow measurement in the system was made at the
supply outlet of the water works. The water level in the storage tanks
regulated the amount of drinking water fed into the supply system as well
as the amounts of water exchanged between the pressure zones and the
storage tanks. The balancing and regulating of the storage tanks inlet and
outlet amounts was not precise enough.
®
In the course of modernizing the piping system, three FLUXUS ADM type
7207 measuring systems were installed in the elevated service reservoir
at Ohlerkirchweg in Mönchengladbach. At the same time, several ultra-
sonic measurements were set up in the historic water towers of the
Viersener and Wickrather streets.
These newly installed measuring systems make it for the first time
possible to exactly monitor and control the amounts of water flowing
through and inside the facility. Thanks to FLEXIM's clamp-on-technique,
the installation was possible without cutting the pipe system or interrupting
operations.

FLUXUS®, WaveInjector® , and PIOX® are protected trademarks of FLEXIM GmbH. Copying and distribution allowed only with the written permission of
FLEXIM GmbH. The copyright of this report, its components, content and pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of
this application report is solely to give general information about the application. It does not assure the suitability of the instrument for a specific purpose.
AR-200510-NVV-EN.doc, 21/09/2005, Page 1 of 1

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963