Beruflich Dokumente
Kultur Dokumente
General Training
Ozcan Akbaba, Middle East Regional Sales Manager
What is a UPS?
U
P
S
Uninteruptable
Power
Supply
Zero
Zero
Power Problems
SPIKES
Power Problems
NOISE
Power Problems
SAGS/
SURGES
Power Problems
BROWNOUTS
Long duration decrease in
voltage (20% or more).
Power Problems
BLACKOUTS
Complete Loss of power.
Blackouts are caused by downed power lines,
open circuit breakers, power plant failures,
etc., resulting in complete data loss, hardware
damage, and equipment overheating.
Types Of UPSs
Stand-by
Line Interactive
Standby UPS
Simplified Block Diagram
Utility Power Mode
INPUT
POWER
Transfer
Relay
BATTERY
CHARGER
INVERTER
BATTERY
SYSTEM
OUTPUT
POWER
Standby UPS
Simplified Block Diagram
Battery Power Mode
INPUT
POWER
Transfer
Relay
BATTERY
CHARGER
INVERTER
BATTERY
SYSTEM
OUTPUT
POWER
Pros
Cons
Low Cost
Small
Light Weight
Efficient
Line-Interactive UPS
Simplified Block Diagram
BUCK & BOOST
CONTACTORS
INPUT
POWER
EMI / RFI
ISOLATION
FILTER
ANTI
BACKFEED
CONTACTOR
CHARGER /
INVERTER
BATTERY
SYSTEM
OUTPUT
POWER
Pros
Cons
Low Cost
CFR UPS
Simplified Block Diagram
Static Switch
UL Contactor
INPUT
POWER
FERRO
CONTROL
PWM
IGBT
INVERTER
BATTERY
SYSTEM
Current sense
BATTERY
CHARGER
Voltage sense
CPU
CONTINUOUS
FILTERED
REGULATED
OUTPUT
POWER
Pros
Cons
Larger/Heavier
More Expensive
INPUT
POWER
RECTIFIER/
CHARGER
INVERTER
BATTERY
SYSTEM
OUTPUT
POWER
Pros
Cons
Automatic Bypass
Built-in AVR (Automatic Voltage Regulation) allows for a wider input voltage range
for world-wide use
Enhanced surge protection capability (TVSS Transient Voltage Surge
Suppressor, LAP Lightning Arrestor Protection)
Enclosures meet specific ingress protection (IPXX) standard for extreme
environments (Zone 4 earthquake, rain test, dust, impact test, etc)
Indoor Solutions
Outdoor/Rugged Solutions
Enclosure
Power Module
ATS
Batteries
Tetrex
Sentra XL
Communication slot
RS 232
USB
EPO
External battery
connector
Continuity
TransformerLESS technology
IGBT:Silicon Controller Rectifier and Inverter
Dual DC bus
Higher efficiency
Lower footprint/weight
Single DC bus
X33 HE series:
10-120kva / pf:0.9
TransformerLESS technology
IGBT:Silicon Controller Rectifier and Inverter
Dual DC bus
Higher efficiency
Lower footprint/weight
LCS screen
TRIPOWERX33 SCR
200/250/300KVA
60/80/100/120/160KVA
10/20/30/40 KVA
TRIPOWERX33 IGBT
Model range available: 10 to 200kV
Three phase input, three phase output
True Online operation, IGBT rectifier technology
Output power factor 0.8
IGBT Rectifier and Inverter
Low Input THD <4%
power factor correction 0.98
RS232 and dry contacts
1+3 Systems (N+1 redundant, redundant, symetric parallel)
High efficiency up to 95%
Tri Power X33 IGBT uses online double conversion (VFI) technology where the load is always powered
by the inverter ensuring a filtered and stabilized sinusoidal voltage. The IGBT rectifier technology
ensures a reduction of consumption of reactive power to minimum levels. This results in lower electricity
bills and smaller genset sizes. Small footprint and light weight makes installations easier and less space is
necessary. Compared to 6 or 12 pulse rectifier systems the heat dissipation is lower and the air condition
size can be dimensioned smaller. This results in less CO2 production saving money and protecting our
environment. The Tri Power X33 IGBT UPS can be used for any kind of load i.e. IT, Industry and
Telecom.
Tri Power X33 HE uses online double conversion (VFI) technology where the load is always powered by the
inverter ensuring a filtered and stabilized sinusoidal voltage manufactured with the state of the art IGBT rectifier
technology. Offering high efficiency values up to 96.5% even in part load situations saves money on electricity bills
protecting at the same time our enviroment with less CO2 consumption. Light weight and small footprint allows
easy, space saving and low cost installation. The 0.9 output power factor provides up to 15% more active power than
a traditional UPS and more load expansion. TRI X33 HE UPS systems are ideal for the protection of critical
information and telecommunications networks which can not run the risk of being powered from a poor quality
electrical supply.
Efficiency matter
3479W
less
2899W
less
Traditional UPS
PF=0.8, n=92%
vs
X33 HE
PF=0.9, n=96%
2319W
less
1740W
less
870W
less
1160W
less
580W less
290W less
37/62
100/120/160/200 kVA
250/300/400 kVA
500/600/800 kVA
HIP spects
Power Range: 100/120/160/200/250/300/400/500
Wide Input Voltage Tolerance based on Loading
Backfeed protection
Jenerator Friendly ( Adjustable rectifier delay, system start delay, soft start time )
Adjustable Battery Charge Current based on loading to charge large battery banks ( for example
250kva UPS provides 50A @100% load , 90A @ 90% , 130A @80%, 156A <70% loading)
Efficiency 94%
X33 HIPs may be connected in a parallel configuration to increase both the reliability of the
power supply to the load and the power available in output. Up to 8 UPSs can be parallel-connected. It is
recommended to connect units of the same power. The load that can be applied to a system with several units
connected in parallel may be greater than the load that can be supported by each individual unit, thanks to
automatic power sharing. The reliability is only increased provided that the total power of the system with one unit
deactivated remains greater than the required power. This condition can be achieved by always adding a
redundant unit. Having a redundant unit means having one more UPS than the minimum number of elements
required to power the load, so that if a faulty unit is automatically excluded
Bypass 1
Mains
Mains
Mains
Mains
System B
System A
UPS 1A
UPS 2A
Battery
Battery
UPS 1B
UPS 2B
Battery
Battery
Sinchroniser
(UGS)
Static Transfer
Switch
Load 3
Load 1
Static Transfer
Switch
Load 4
Load 2
t
0 30s
0 120s
input
current
t
t0
Power Walk-in
delay timer
t1
t2
Power Walk-in
100 %
75 %
UPS1+
UPS2+
UPS3+
UPS4
50 %
25 %
UPS1+
UPS2+
UPS 3
UPS1+UPS2
UPS1
Input Mains
30
UPS 1
UPS 2
UPS 3
UPS 4
Battery
Battery
Battery
Battery
Load
60
90
Seconds
Structure
Tri Power X33 Mod is a complete Modular UPS
with range from 10kVA up to 60kVA
Power
Modules
Battery
Drawers
(3.4/5 kva)
Inverter
Cabinet
Battery
Cabinet
Inverter Cabinet
Five models mounting 3.4 and 5kVA Power Modules
3 Modules
6 Modules
6 Modules
9 Modules
12 Modules
(20/30 kVA)
(30 kVA)
(30 or 45 kVA)
(40 or 60 kVA)
Battery Cabinet
A Simple Cabinet which contains Battery Drawers.
used with inverter cabinets which have no internal battery drawers
or
for long autonomy configuration.
One Model:
Housing 20 Battery
Drawers ( each has
12V 9Ah batteries)
52/62
REDUNDANCY
ZERO DOWNTIME
EASY
MAINTENANCE
REDUCED MTTR
LOW TCO
REDUCED PLANNING&INSTALLATION
COSTS
HIGH
EFFICIENCY
SMALL FOOT
PRINT
SPACE OPTIMIZATION
Flexibility
Power Sharing
N+X Redundancy
Power and Autonomy
Scalability
Easy Management,
Service and Maintenance
54/62
Flexibility
Redundancy
System Redundancy on single phase loads
Example: Tri Power X33 Mod 20 kVA with single phase load rated less
then 17 kVA
R
Power Module
8.5kg
Battery drawer 13 kg
Pag. 57
Needs:
High performances
Reliability
Easy management
Fast service
High communication level
Flexibility
Low environmental impact
Loads nature:
Sensitive
Intelligent
Critical
Input PF:
THDi:
Voltage:
Frequency:
Standards
0.99
<3%
230 +15% -20%
400 +15% -20%
50/60Hz
+/-2%; +/-14%
Output
Voltage tollerance:
+/-1%
THDo:
<1%
Current crest factor:
3.5:1
Frequency:
50Hz/60Hz <1%
High dynamic performances on both linear
and not linear load variations
Other
Acoustic Noise:
42 46dBA@1mt
EN 62040-1-1
EN 62040-2
EN 62040-3
VFI SS 111
1645mm
414mm
628mm
341 Kg
Foot Print
Tri Power X33 Mod
Traditional UPS
20kVA + Batt
Single UPS cabinet
Foot print: 0.26 m2
50 kVA + Batt
Single UPS cabinet
Foot print: ~ 0.72m2
Pag. 62
Bypass System
Tri Power X33 Mod bypass systems:
1. General manual bypass;
Compleate measures
Advanced features
Diagnostics
Full Communication
Conclusions 1
Easy management
High performances
Reliability
Fast service
Flexibility
Intelligence
Scalability
Communication
Tri Power X33 Mod
Conclusions 2
Conclusions 3
Why Tri Power X33 Mod..????
4products1..less warehouse
Few parts.easier for service
Configurator
STS 100600A
STS spects
Why STS ?
Why STS?
Thank you
Ozcan Akbaba
Regional Sales Manager ME