Alpha Technologies

INDOOR UPS product training

General Training
Ozcan Akbaba, Middle East Regional Sales Manager

What is a UPS?

U
P
S

Uninteruptable

Power
Supply

Some Reasons for Using a UPS

Poor Power Quality

Critical Equipment Needs to Stay Running


Carry through until Emergency
Generator Starts

Unattended Shutdown of Computers on


Power Fail

UPS Output Waveforms


Sine Wave
170 Vpeak
120 Vrms

Zero

Quasi Sine wave (stepped square wave)


170 Vpeak
120 Vrms

Zero

Power Problems

SPIKES

Sharp increases in electrical


energy reaching as high as 600
volts and lasting up to second.

Spikes are caused by lightning, fluorescent


lighting, air conditioners, copy machines,
elevators, etc., resulting in data error and/or
hardware damage.

Power Problems

NOISE

High frequency interference


appearing on the AC line
Noise is caused by static, transformers, faulty
light fixtures, broadcast equipment, auto
ignitions, appliances, etc., resulting in garbled
data, keyboard lockups, and semiconductor
damage.

Power Problems

SAGS/
SURGES

Short duration changes


in voltage levels.
Sags or Surges are caused by the startup of
electric motors, air conditioners, transformers,
machine shops, utility switching, etc., resulting
in data errors, equipment overheating, and
premature equipment failures.

Power Problems

BROWNOUTS
Long duration decrease in
voltage (20% or more).

Brownouts are usually caused by peak period


overloads, power network switching, faulty
wiring, etc., resulting in data loss, hardware
damage, and equipment overheating.

Power Problems

BLACKOUTS
Complete Loss of power.
Blackouts are caused by downed power lines,
open circuit breakers, power plant failures,
etc., resulting in complete data loss, hardware
damage, and equipment overheating.

Types Of UPSs

Stand-by
Line Interactive

Double Conversion (Online)


Ferro Resonant / Controlled Ferro Resonant

Standby UPS
Simplified Block Diagram
Utility Power Mode
INPUT
POWER
Transfer
Relay
BATTERY
CHARGER

INVERTER

BATTERY
SYSTEM

OUTPUT
POWER

Standby UPS
Simplified Block Diagram
Battery Power Mode
INPUT
POWER
Transfer
Relay
BATTERY
CHARGER

INVERTER

BATTERY
SYSTEM

OUTPUT
POWER

Pros and Cons of a Standby UPS

Pros

Cons

Low Cost

Minimal Load Protection

Small

2-4 ms typical transfer time

Light Weight
Efficient

Line-Interactive UPS
Simplified Block Diagram
BUCK & BOOST
CONTACTORS

INPUT
POWER

EMI / RFI
ISOLATION
FILTER

ANTI
BACKFEED
CONTACTOR
CHARGER /
INVERTER

BATTERY
SYSTEM

OUTPUT
POWER

Pros and Cons of a Line Interactive UPS

Pros

Cons

Low Cost

Minimal Load Protection

Quasi Output Regulation

2-4 ms typical transfer time

Wider Input Range


Efficient

CFR UPS
Simplified Block Diagram
Static Switch
UL Contactor

INPUT
POWER
FERRO
CONTROL

PWM
IGBT
INVERTER

BATTERY
SYSTEM

Current sense

BATTERY
CHARGER

Voltage sense

CPU

CONTINUOUS
FILTERED
REGULATED
OUTPUT
POWER

Pros and Cons of a CFR UPS

Pros

Cons

100% Power conditioning

Larger/Heavier

Complete I/O Isolation

More Expensive

Power Factor Correcting


Better Output Flexibility

Double Conversion UPS


Simplified Block Diagram
BYPASS

INPUT
POWER

RECTIFIER/
CHARGER

INVERTER

BATTERY
SYSTEM

OUTPUT
POWER

Pros and Cons of a Double Conversion UPS

Pros

Cons

100% Power conditioning

Higher Heat Output

Automatic Bypass

More Expensive than


Line Interactive

Power Factor Correcting


No Transfer Time

What Does Alpha Offer


to the AC UPS Market?

Indoor vs. Outdoor Product


Alpha provides long run time products for two main
markets: indoor and rugged or outdoor
applications:
Indoor Applications: applications with controlled
environment, mostly free of dust, and where the
temperature is between 0 and 40 C
Outdoor/Rugged Applications: Applications where
there may be one or all of:
Extreme temperatures
High humidity
Dust
Vibration

Key Features of Outdoor/Rugged UPS


Conformal coated PCBs protect against exposure to moisture and high humidity
environment
Designed to operate under extreme temperature conditions (-40C to +74C)
Made of rugged electric and electronic components:
due to the fact that the UPS is designed for extreme
conditions, the elements that make the UPS are also
designed for extreme conditions.

Thermostatically controlled battery heater mats available


Temperature compensation utilized to effectively manage
the battery charge voltage based on temperature
Remote monitoring via SNMP web-based communication

Built-in AVR (Automatic Voltage Regulation) allows for a wider input voltage range
for world-wide use
Enhanced surge protection capability (TVSS Transient Voltage Surge
Suppressor, LAP Lightning Arrestor Protection)
Enclosures meet specific ingress protection (IPXX) standard for extreme
environments (Zone 4 earthquake, rain test, dust, impact test, etc)

Indoor Solutions

Outdoor/Rugged Solutions

-Self contained units with all the


components inside a close enclosure

-System made by several components,


each selected to suit a specific project

-Extra-Batteries available as add-on


battery packs

- Ground, Pole, and Wall mount options

- Tower and Rack mount options

Enclosure

Power Module
ATS

Batteries

Indoor UPS matrix

Tetrex

Line Interactive Design


Modified sine-wave output
Ideal for workstations
Models available from 500VA to 800VA
Available as tower models
Fully digitized microprocessor controlled
USB communication standard
24-month limited warranty

Sentra XL

Line Interactive Design


Models from 1 kVA up to 3 kVA
High output PF 0.9
Ideal for SOHO business:
workstations, servers, small data networks
Fully digitized microprocessor controlled
Power factor correction
SNMP internal slot included for web agent
Extended battery connector included
USB/RS232 interface included for communication
Tower/Rackmount convertible design
4 A charger for fast recharge time
200W charger built in every battery pack
24-month limited warranty

A Tour of the Sentra XL

Communication slot

Air ventilation holes

RS 232

USB
EPO

Output IEC 320

External battery
connector

Input IEC 320

Continuity

True Online operation


Zero transfer time in the event of a power disruption
Models from 1 kVA up to 10 kVA
High output PF 0.8 up to 3 kVA, 0.9 at 6 and 10kVA model
Ideal for mission-critical applications: servers, voice and data networks
Fully digitized microprocessor controlled
Power factor correction
SNMP internal slot included for web agent
Extended battery connector included
USB/RS232 interface included for communication
Tower/Rackmount convertible design
Up to 4 units in parallel (6 and 10kVA)
200W charger built in every battery pack
24-month limited warranty

A Tour of the Continuity

three phase UPS

Tri Power X31HE UPS

Three phase input, single phase output


True Online operation, IGBT rectifier technology
High Efficiency up to 96.5% in online mode
Output Power Factor 0.8
Input Power factor correction 0.99
THDI < 3%
Zero transfer time in the event of a power disruption
Ideal for mission-critical applications: servers, voice and data centers
Models available from 10kVA to 20kVA
Fully digitized microprocessor controlled
SNMP internal slot included for web agent
Installation in parallel mode up to 8 units
Up to 2 hours runtime at full load
24-month limited warranty

Tri Power X33 UPS

Three phase input, three phase output


Zero transfer time in the event of a power disruption
Ideal for mission-critical applications:
industrial and genset applications
Models available from 20kVA to 800kVA
Available as Tower
Fully digitized microprocessor controlled
Power factor correction
SNMP external for web agent
Installation in parallel mode up to 8 units
Up to 2 hours runtime at full load (up to 60 kVA)
24-month limited warranty

Tri Power X33 UPS


X33SCR series:
10-300kva / pf:0.8

X33 IGBT series:


10-120kva / pf:0.8

Transformer base technology


SCR:Silicon Controller Rectifier
( Thyristor base rectfier)

TransformerLESS technology
IGBT:Silicon Controller Rectifier and Inverter
Dual DC bus
Higher efficiency
Lower footprint/weight

10/15/20/30/40/60/80/100/120/160 : 6 PULSE RECTIFIER


200/250/300; 12 PULSE RECTIFIER

Single DC bus

X33 HE series:
10-120kva / pf:0.9
TransformerLESS technology
IGBT:Silicon Controller Rectifier and Inverter
Dual DC bus
Higher efficiency
Lower footprint/weight
LCS screen

TRIPOWERX33 SCR

200/250/300KVA

60/80/100/120/160KVA

Model range available: 10 to 300kVA


Galvanic isolation transformer at the inverter output
Non-linear load driving capability
RS232 and dry contacts
Overload and short circuit protection
Emergency stop utility

10/20/30/40 KVA

TRIPOWERX33 IGBT
Model range available: 10 to 200kV
Three phase input, three phase output
True Online operation, IGBT rectifier technology
Output power factor 0.8
IGBT Rectifier and Inverter
Low Input THD <4%
power factor correction 0.98
RS232 and dry contacts
1+3 Systems (N+1 redundant, redundant, symetric parallel)
High efficiency up to 95%
Tri Power X33 IGBT uses online double conversion (VFI) technology where the load is always powered
by the inverter ensuring a filtered and stabilized sinusoidal voltage. The IGBT rectifier technology
ensures a reduction of consumption of reactive power to minimum levels. This results in lower electricity
bills and smaller genset sizes. Small footprint and light weight makes installations easier and less space is
necessary. Compared to 6 or 12 pulse rectifier systems the heat dissipation is lower and the air condition
size can be dimensioned smaller. This results in less CO2 production saving money and protecting our
environment. The Tri Power X33 IGBT UPS can be used for any kind of load i.e. IT, Industry and
Telecom.

Tri Power X33HE UPS

Three phase input, three phase output


True Online operation, IGBT rectifier technology
Transformerless Technology
High Efficiency up to 96.5% in online mode
Output Power Factor 0.9
THDI < 3%
Zero transfer time
Ideal for mission-critical applications
Models available from 10kVA to 120kVA
Fully digitized microprocessor controlled
Power factor correction 0.99
SNMP internal slot included for web agent
Installation in parallel mode up to 8 units

Tri Power X33 HE uses online double conversion (VFI) technology where the load is always powered by the
inverter ensuring a filtered and stabilized sinusoidal voltage manufactured with the state of the art IGBT rectifier
technology. Offering high efficiency values up to 96.5% even in part load situations saves money on electricity bills
protecting at the same time our enviroment with less CO2 consumption. Light weight and small footprint allows
easy, space saving and low cost installation. The 0.9 output power factor provides up to 15% more active power than
a traditional UPS and more load expansion. TRI X33 HE UPS systems are ideal for the protection of critical
information and telecommunications networks which can not run the risk of being powered from a poor quality
electrical supply.

Efficiency matter
3479W
less
2899W
less

Traditional UPS
PF=0.8, n=92%
vs
X33 HE
PF=0.9, n=96%

2319W
less
1740W
less

870W
less

1160W
less

580W less
290W less

37/62

TRIPOWER X33 HIP

100/120/160/200 kVA

250/300/400 kVA

500/600/800 kVA

HIP spects
Power Range: 100/120/160/200/250/300/400/500
Wide Input Voltage Tolerance based on Loading

400Vac +20%...-10% @100% load +20%, -40% @65% load


Input Power Factor Correction >0.99
IGBT Rectifier 100-500 kva , THDi <3% @100%, <5% @75%, <8% 25-50% load

Backfeed protection
Jenerator Friendly ( Adjustable rectifier delay, system start delay, soft start time )

Adjustable Battery Charge Current based on loading to charge large battery banks ( for example
250kva UPS provides 50A @100% load , 90A @ 90% , 130A @80%, 156A <70% loading)

DC Bus: 40 pcs 12V / 240 pcs 2V battery


Transformer Base IGBT Inverter
Output Power Factor: 0.8 /0.9

Efficiency 94%

Up to 8 units/ Parallel , Redundant Configuration (Hot syncroni zation)

HIP block diagram

Parallel Operation ( up to 8 units)

X33 HIPs may be connected in a parallel configuration to increase both the reliability of the
power supply to the load and the power available in output. Up to 8 UPSs can be parallel-connected. It is
recommended to connect units of the same power. The load that can be applied to a system with several units
connected in parallel may be greater than the load that can be supported by each individual unit, thanks to
automatic power sharing. The reliability is only increased provided that the total power of the system with one unit
deactivated remains greater than the required power. This condition can be achieved by always adding a
redundant unit. Having a redundant unit means having one more UPS than the minimum number of elements
required to power the load, so that if a faulty unit is automatically excluded

Dual Bus Configuration


Dual Bus with MP Systems
Bypass 2

Bypass 1

Mains

Mains

Mains

Mains

System B

System A
UPS 1A

UPS 2A

Battery

Battery

UPS 1B

UPS 2B

Battery

Battery

Sinchroniser
(UGS)

Static Transfer
Switch

Load 3

Load 1

Static Transfer
Switch
Load 4

Load 2

ZERO IMPACT SOURCE


Input

Power walk-in (0 to 100%) and Power walk-in delay timer


black out
input
voltage

t
0 30s

0 120s
input
current

t
t0

Power Walk-in
delay timer

t1

t2
Power Walk-in

ZERO IMPACT SOURCE


Power walk-in (0 to 100%) and Power walk-in delay timer
for parallel system
Output Power
Generator (kVA)

Can be used a smaller


Gen Set !!!

100 %

75 %
UPS1+
UPS2+
UPS3+
UPS4

50 %

25 %

UPS1+
UPS2+
UPS 3

UPS1+UPS2
UPS1

Input Mains

30

UPS 1

UPS 2

UPS 3

UPS 4

Battery

Battery

Battery

Battery

Load

60

90

Seconds

New three phase


modular UPS

Structure
Tri Power X33 Mod is a complete Modular UPS
with range from 10kVA up to 60kVA

Tri Power X33 Mod components


overview
Tri Power X33 Mod is composed by:

Power
Modules

Battery
Drawers

(3.4/5 kva)
Inverter
Cabinet

Battery
Cabinet

Inverter Cabinet
Five models mounting 3.4 and 5kVA Power Modules

3 Modules

6 Modules

6 Modules

9 Modules

12 Modules

(10 /15 kVA)

(20/30 kVA)

(30 kVA)

(30 or 45 kVA)

(40 or 60 kVA)

Battery Cabinet
A Simple Cabinet which contains Battery Drawers.
used with inverter cabinets which have no internal battery drawers
or
for long autonomy configuration.

One Model:

Housing 20 Battery
Drawers ( each has
12V 9Ah batteries)

52/62

End User Advantages


MODULAR
SCALABILITY

BUY ONLY WHAT YOU NEED

REDUNDANCY

ZERO DOWNTIME

EASY
MAINTENANCE

REDUCED MTTR

LOW TCO

REDUCED PLANNING&INSTALLATION
COSTS

HIGH
EFFICIENCY

LOWER ENERGY LOSSES

SMALL FOOT
PRINT

SPACE OPTIMIZATION

Modular Architecture Plus


Modular Architecture :

Flexibility
Power Sharing
N+X Redundancy
Power and Autonomy
Scalability
Easy Management,
Service and Maintenance

54/62

Flexibility

Thanks to the innovative


architecture, the Tri Power
X33 Mod can adapt it self
to any kind of electrical
connection.

Redundancy
System Redundancy on single phase loads

Example: Tri Power X33 Mod 20 kVA with single phase load rated less
then 17 kVA
R

Easy and Quick Component


Installation and Replacement
Plug and play technology
Power Modules automatically
detected
System auto configuring
NO Further HW and SW settings

Power Module
8.5kg

Only one tool is needed:


A Screwdriver

Battery drawer 13 kg
Pag. 57

Easy to move and place


Only one person can
move place and install
the complete system

Weels in the rear


feet for easy move

Ideal UPS technology features


Applications:
Data storage
Information
Communication
Emergency
Security

Needs:
High performances
Reliability
Easy management
Fast service
High communication level
Flexibility
Low environmental impact

Loads nature:
Sensitive
Intelligent
Critical

General Technical Specifications


Input

Input PF:
THDi:
Voltage:

Frequency:

Standards

0.99
<3%
230 +15% -20%
400 +15% -20%
50/60Hz
+/-2%; +/-14%

Output
Voltage tollerance:
+/-1%
THDo:
<1%
Current crest factor:
3.5:1
Frequency:
50Hz/60Hz <1%
High dynamic performances on both linear
and not linear load variations

Other
Acoustic Noise:
42 46dBA@1mt

EN 62040-1-1
EN 62040-2
EN 62040-3

VFI SS 111

Efficiency (On Line) up to 95%


Efficiency (Eco Mode) up to 99%

High Power Density


Small and light cabinets

Small foot print

1645mm

414mm

628mm

341 Kg

Foot Print
Tri Power X33 Mod

Traditional UPS

20kVA + Batt
Single UPS cabinet
Foot print: 0.26 m2

50 kVA + Batt
Single UPS cabinet
Foot print: ~ 0.72m2

Pag. 62

Bypass System
Tri Power X33 Mod bypass systems:
1. General manual bypass;

2. Internal automatic bypass in each


power module to exclude
the whole UPS
particular phase

Info, Measurement and


Diagnostics

Compleate measures

Full parameters monitor


and control

Advanced features

Events, alarms and


history data

Diagnostics

Full Communication

Communication RS 232 serial port


Maintenance RS 232 serial port
Logic level port
Dry contact port

Net adapter (SNMP) intelligent slot

Emergency Power Off

Conclusions 1
Easy management

High performances

Reliability

Fast service

Flexibility

Intelligence

Scalability

Communication
Tri Power X33 Mod

Conclusions 2

Reliability: save money, avoiding problems


Flexibility & scalability: save money, growing in power and runtime
High technology: save money, having always high efficiency
High performances: save money, saving energy

Conclusions 3
Why Tri Power X33 Mod..????

Small power modules . more redundance


Little footprint ....more space

4products1..less warehouse
Few parts.easier for service

Configurator

STS 100600A

STS spects

Why STS ?

Why STS?

Detailed Line Diagram/ Control Panel

Remote Communication/ SNMP

Remote Communication/ Relays

Thank you

Ozcan Akbaba
Regional Sales Manager ME