Sie sind auf Seite 1von 484

Products Guide 2015

The company
Giordano Riello, founder and chairman of Aermec, assisted by his son
Alessandro and daughter Raffaella, has solidly associated the Company
name with precise values:
Respect for the environment by using new eco-friendly refrigerants as
well as innovative installations using water as the carrier fluid.
Noise pollution control with low-noise emission products, which
undergo scrupulous testing before being put on the market.
Energy saving, the great challenge of the Third Millennium, with the
development of combined heating and air conditioning systems where
appliances are used only as and when necessary.
Health care special filters trap the smallest particles in suspension and
the Plasmacluster system cleans the air of dust mites and moulds, making
for a cleaner, healthier environment and with the new germicidal lamps
eliminating all virus and batteries.

Hystory
1961 Giordano Riello sets up Riello Condizionatori, initially producing for
contractors only. The story begins.
1963 The Aermec brand is born and marks all future company products designed
and manufactured on site.
The brand name gains a stronghold as a major product name in Italy and
throughout Europe.
1970 Aermec can already supply fresh and warm air. Aermec presents the
first dual section conditioner: the first split-system. Fancoil production
starts.
1980 The Eighties sees the development of water chillers and air handling units.
1990 The Nineties mark the definitive consolidation of the company on the market.
The Aermec brand is associated with advanced technology and high quality
design.
1998 The name makes the company. From 1 January Aermec becomes the
company name as well as product brand.
2000 The company consolidated its leadership in the production of fancoils, and
laid the technological and production basis for strong growth in the field of
high powered air-conditioning systems.
2002 Design and technology: Aermec launched Omnia a new generation of
fancoils, designed for domestic applications. OMNIA is the result of co
operation with a worldwide prestigious designer.
2004 The international market ask for number and Aermec answer. Giordano Riello
make the producing system more technogical. High producing, quality and
assistance: the success of Aermec is going to continue.
2006 Aermec consolidated its presence in world markets with system appliances. A
series of models to meet all design engineering requirements.
2008 Aermec responds with more and more efficient units to the world challenge
of energy saving with a special attention for our environment.
2010 Aermec extends the use of inverter technology on its fancoils and chillers.
The perfect integration of the new inverter technology with the most
sophisticated control systems is best expressed in the VMF (Variable Multi
Flow) Hydronic System - anew way to interpret comfort in the home and
elsewhere.
2011 Aermec turns 50. The company has developed and enlarged, always willing
to understand and anticipate the needs of the market with innovative and
quality products.
Quality in innovation, in products, in pre-sales and after-sales services.
Promotion of the philosophy of integrated design between designer and
architect.
Past success represents the commitment to the future.

01. HYDRONIC TERMINALS


FAN COILS
t
FCX
FCXI
DUALJET
Omnia HL
Omnia UL
Omnia Radiant

Inverter




A
(m/h)
110-1300
140-1140
140-720
80-460
80-460
80-460

C.C.
(kW)
1-7,6
1,5-8,6
1,5-4,2
0,8-2,8
0,8-2,8
2-2,8

H. C.
(kW)
2,3-17
2,9-17
2,9-8,2
2,0-5,9
2,0-5,9
4,6-5,9

110-1300
140-1140
80-460

1-7,6
1,5-8,6
0,8-2,8

2,29-17
2,96-17
2,0-5,9

30
34
38

160-805
750-2440
160-805
1060-2410

1,6-5,3
6,9-16
1,6-5,3
7,76-16

3,6-10,9
15,9-31,7
3,6-10,9
17,5-31,7

40
44
48
52

130-613
130-613
260-1750
260-1750

1,32-4,28
1,32-4,28
1,9-8,8
1,9-8,8

270-684

1,9-4,0

4,0-8,5

140-1140

1,5-6,9

2,9-15,1 70

Page
12
16
20
22
24
26

Witht ainet neaed eiing intaan ith ta ee


FCX_P
FCXI_P
Omnia UL_P

Inverter

Witht ainet dt intaan ith high ta ee


VED (030-340)
VED (430-741)
VED_I (030-340)
VED_I (430-741)

W
W
/W
/W

Caee eiing intaan


VEC
VEC_I
FCL
FCLI


/

Inverter

56
58
3,9-21,7 60
3,9-21,7 64

With ainet a intaan


FCW

68

With ainet eating gemiida am


FHX



Fan i intaan nt and eiin deie


PMZ
Venaama
Cnt ane
VMF

D
d

sD&

74
76
78
80

THERMOCONVECTORS
CLIMAFON
CLIMABOX

t
t

0,9-2,5
1,2-2,1

84
86

02. HEAT RECOVERY UNITS


REPURO
TRS
UR
RPF
HRS
URX_CF
URHE_CF
ERS
ERSR

t
t
t
,
t
t
,
,
,

100-650
150-1000
350-3300
790-4250
300-3920
750-3300
1000-3300
1000-5000
1100-16100

90
98
100
102
106
110
114
118
122

03. AIR HANDLING UNITS


AIR CONDITIONING UNITS
TUN
TS
TDA
TA
TN







Ai ate
(m/h)
900-4000
930-4200
800-3500
900-5000
3000-23000

C.Ca.
(kW)
4,7-26,4
4,85-24,8
4,9-17,9
4,7-31,8
15,6-96,4

Heat. Ca.
(kW)
11,2-51,1
9,8-52,0
10,4-41,2
14,2-78,3
25,2-178,5

Page
128
132
134
136
140

MODULAR AIR HANDLING UNITS


NCS
NCD
NCD_H
SPL 025-130
SPL 160-230
ENERGY

&
&
&
&
&
,

907-51994
1370-103550
1800-30780
2500-13000
16000-25000
4000-25000

144
146
150
152
156
160

PAC<AGED ROOFTOP UNITS


RTX 09-16
ne RTX 17-23
RTY 01-10
RTE 25-200
RTE 240-400
RTE 480-800

&
&
&
&
&
&

51,6-129,9
149-291
30-134,8
11,1-55,9
82,5-152,1
155,7-274,4

50-127,5
145-289
29,1-142,2
11,5-55,7
77,5-148
158,1-278,8

164
168
172
176
180
184

04. CHILLERS & HEAT PUMPS


AIRWATER CHILLERS AND REVERSIBLE HEAT PUMPS
Unit ith me
IDROBLOC
ANL 020-202
ANL 290-650
ANL 290H-650H
ANLI 021H-101H
ANK 020H-150H
HBI 060-160
SWP
NRL 0280-0750
NRL 0280H-0750H
NRL 0800H-1800H
ne NRB 0800-3600
ne NRB 0800H-3600H
NRK 0200-0700




Z
Z
Z
Z
,

Z
Z

Z
Z

3,5
5,65-43,7
55-133
53-128
5,7-29,4
6,7-29,2
5,5-15,5

3,8
190
6,1-45,7 192
196
61-142 200
 204
7,8-33,5 208
 212
2,1
216
52,6-194
218
50,6-178,9 58,4-205,3 222
183-470
228-526 226
217-1047
230
196-969 210-1009 234
33,5-148 42,3-175 238

Unit ith me and entiga Pg Fan


MEC-W
CL 025-200
NRC 0275-1000
ne NLC 0280-1250H

t
W&
W&
ZW&

11-55
5,82-41,3
46-263
52-316

242
7,85-43,8 244
248
56,5-349 252

302-2100
235-670
262-1249

256
276-789 264
272

Unit ith e me
NSM 1402-9603
NSH 1251-3602
NSI 1251-5403


Z


04. CHILLERS & HEAT PUMPS (nned)


AIRWATER CHILLERS AND REVERSIBLE HEAT PUMPS
Unit ith entiga me
TBX 1401-4102



Ai ate
(m/h)

C.Ca.
(kW)
259-861

Heat. Ca.
(kW)
Page
276

43-184
199-475

46-203 280
242-547 284

59-191
196-452
456-904
306-2028
243-1554
306-2028
243-1554
257-1193

288
292
296
300
308
316
324
332

6,9-9,7
6,5-43,6
50-168
6,2-40,2
45-157
105-384

7,7-10,8 336
338
342
7,8-47,9 346
53-184 350
119-434 354

146-712
171-701
166-668
630-1549
628-1524

358
362
190-819 366
370
374

Unit imtane and indeendent dn ht and d ate


NRP 0200-0750
NRP 0800-1800

Z
Z

Chie ith ee ing


NRL 0280-0750FC
NRL 0800-1800FC
NRL 2000-3600FC
ne NSM 1402-9603FC
NS 1251-7203FC HWT
ne NSM 1402-9603FC
NS 1251-7203FC HWT
NSI 1251-5403FC





,td

,td


WATERWATER CHILLERS AND REVERSIBLE HEAT PUMPS


Unit ith me
VENICE
WRL 026-161
WRL 180-650
WRL 026H-161H
WRL 180H-650H
NXW 0500-1400




Z
Z
Z

Unit ith e me
WSA 0601-2802
WSB 0701-2802
WSH 0701-2502
WF 2512-6412
HWF 2512-6412



Z



Unit ith entiga me


TW 110



284

378

Unit imtane and indeendent dn ht and d ate


NXP 0500-1650

Z

109-501

123-560 380

COMPONENTS FOR CHILLERS & HEAT PUMPS


SAP
WST
TRA
CSE-CDR-CVR-CGA-CMV
WTE-WTR-WDR-WTS-WTA
DMP


W

Z

Z

384
388
392
394
406
414

05. PRECISION AIR CONDITIONERS


DAS 06-60
DAC 09-31
DAC 06-35





6,4-64,7
16-150
6-200

418
422
426

06. ROOM AIR CONDITIONERS


C.Ca.
(kW)
2,5-6,5
2,6-6,4
2,6-6,4
2,7-17,5
20-39,5
0,9-8
0,9-4

Heat. Ca.
(kW)
2,7-7
3-7
2,7-6,4
2,9-20
22-42
0,9-9,5
0,9-6

432
434
436
438
442
444
443

Z
Z

2-13,6
5,2-8,4

2,5-14
6,8-9

448
452

Z,t
Z
Z
Z

10-16
10-60
12-28
22-180

11-17,6
11-63
14-30
22-200

456
460
464
468

Ai ate
(m/h)

MONOSPLIT
ne SE

SI
HWI
LCI
DXE
EWIH
EFSI

Z/
Z
Z
Z
Z
Z
Z

Page

MULTISPLIT
MKM
MIH

VRF SYSTEM
MDW
MVF-MDS
ne MVAS
ne MVAM

ASSOCIATED SOLUTIONS
SMUFFO
CWX
FW-R

W
t
t

3,5-6,7
2,9-4

472
474
478

FCX

Fan coils
Universal and floor installation

Aermec
participate in the EUROVENT program: FCH
the products are present on the site
www.eurovent-certification.com

FCX_A
ZX

housing: RAL 9002


head and feet: RAL 7044

FCX-U

Features
Fan coils for heating, cooling, and dehumidifying.
FCX is designed to maintain in time the set temperature,
ensuring very low sound levels. Installed in any type of plant
2/4 tubes and in combination with any of the heat generator
even at low temperatures.
Thanks to the availability of different versions, with front or
lower air intake, with standard battery or increased, for horizontal or vertical installation, it is easy to choose the optimal
solution for any need.
- Vertical installation:
FCX-A: vertical free-standing with switch
FCX-AS: vertical free-standing without switch. Compatible
with the VMF system
FCX-ACT: vertical free standing with electronic thermostat
FCX-APC: (FCX 22, 24, 32, 34, 36, 42, 44, 50, 54, 56, 62,
64, 82, 84) vertical free-standing with electronic thermostat
and Plasmacluster purifier

Rounded line
Automatic fan coil switch-off with closure of the air distribution grille
- Vertical and horizontal installation:
FCX-U: universal floor or wall/ceiling mounting. Broad range of controls
Adjustable air distribution grille, except for models 62, Metallic protective cabinet with rustproofing polyester
paint
64, 82, 84 and 102. Compatible with the VMF system
Quiet operation
FCX-UA: universal floor or wall/ceiling mounting. Grille
Low loss of charge in the heat exchange batteries
with fixed fins. Compatible with the VMF system
Electric motors with permanently inserted condensers
FCX-UE: universal floor or wall/ceiling mounting with direct
Ease of installation and maintenance
expansion coil. Adjustable air distribution grille, except for
Air filter easy to remove and clean
models 62, 82 and 102.
Extractable shrouds for easy, effective cleaning
Versions standar coil (FCX 17, 22, 32, 36, 42, 50, 56, 62,
Water connections can be reversed during installation
82 and 102)
phase
Versions increased coil (FCX 24, 34, 44, 54, 64, and 84)
3-speed ventilating unit
Full compliance with the accident prevention standards
FCX-B: front suction, without selector. Compatible with
the VMF system

VERSION
FCX A
FCX AS
FCX ACT
FCX APC

17
17
17
-

22
22
22
22

24
24
24
24

32
32
32
32

34
34
34
34

36
36
36
36

42
42
42
42

AVAILABLE SIZES
44
50
44
50
44
50
44
50

FCX B

17

22

24

32

34

36

42

44

FCX U
FCX UA
FCX UE

17
17
-

22
22
22

24
24
-

32
32
32

34
34
-

36
36
-

42
42
42

44
44
-

54
54
54
54

56
56
56
56

62
62
62
62

64
64
64
64

82
82
82
82

84
84
84
84

102
102
102
-

50

54

56

62

64

82

84

102

50
50
50

54
54
-

56
56
-

62
62

64
-

82
82

84
-

102
102

Accessories
AMP: kit for the wall mounting installation of
SIT5 card.
versions FCX U and UE.
SIT5: commands the 3 fan speeds and up to 2
BC: Auxiliary condensate drip tray. Use the BC 5-6
valves (four pipes systems); sends the commands
tray accessory if horizontal, or BC 4 if vertical.
of the thermostat to the fan coils network.
BV: Single row hot water coil. Not available for SW3: water temperature probe that gives the auto4-row versions or those with Plasmacluster.
matic season change feature to electronic thermo DSC4: Condensate drainage device for use when
stats supplied with water-side change over.
natural run-off is not possible.
SWA: SWA external probe accessory (length L =
PC: Sheet metal panel to close rear of unit.
6m). The probe detects the temperature of the
RX: Armoured electric coil with safety thermoambient air if connected to the connector (A) of
stat. (Requires a thermostat with heater managethe panel FMT21; the ambient air temperature
ment). Not available for 4-row versions or those
probe incorporated in the panel is automatically
with Plasmacluster.
deactivated. Detects the temperature of the
SE: Manually operated fresh air intake louver.
water in the system, for ventilation consent, if
SIT 3 - 5: Thermostat Interface Cards. They allow
connected to the connector (W) of the FMT21
the creation of a network of fan coils (max. 10)
panel. Two SWA probes can be connected to the
commanded by a central control panel (selector
panel FMT21 simultaneously.
or thermostat).
VCF: the kit contains a motorised 3-way valve with
SIT3: commands the 3 fan speeds and must be
insulating shell, plus coupling and pipes in insulated
installed on each fan coil of the network;
copper. For 3/4-row and 1-row coils (BV). Combine
receives the commands from the selector or the
the SW3 probe with FCX ACT, too. Versions with

12

230V and 24V~50Hz power supply.


VCFD: Kit consisting of powered 2-way valve,
copper couplings and pipes. For 3/4-row and
1-row coils (BV). Combine the SW3 probe with
FCX ACT, too. Versions with 230V and
24V~50Hz power supply.
VCF_X4: The valve kits are designed for fan coil
units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits
totally separated. The kit consists of 2 valves of
3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves
and associated hydraulic piping. VCF1X4L Valve
kit for left hand connection fan coil units.
VCF1X4R Valve kit for right hand connection
fan coil units. Power supply: 230V ~ 50Hz.
ZX: Feet for floor-standing installations for A-ASACT-APC models.
Control panels(1) and VMF System(2): the characteristics are described on the appropriate card.

Accessories
FMT10 FMT21
KTLM
PTI
PX PX2 PX2C6
PXBI PXAI
PXAE
PXAR
TF1
TPF
WMT05 WMT06 WMT10
VMF-E4 VMF-E4D
VMF-E2
VMF-E0 VMF-E1
AMP
AMP20
4
5
BC
6
117
122
BV
132
142
162
DSC4
17
18
22
23
32
PC
33
42
43
62
17
22
32
RX
42
52
62
15X
20X
30X
SE
40X
80X
3
SIT
5
SW3
SWA
1X4L - 1X4R
2X4L - 2X4R
3X4L - 3X4R
41-4124
VCF
42-4224
43-4324
44-4424
45-4524
1-124
2-224
VCFD
3-324
4-424
5
ZX
6

(1)
(1)
(1)
(1) (3)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)
(2)

(4)
(4)
(4)
(4)
(4)
(5)(6)

(4)
(4)
(4)
(4)
(4)
(4)

17

22

24

32

34

36

42

Size
44 50

Versions
54

56

62

64

82

84

102

(7)
(7)
(7)
(7)(8)
(7)(8)
(7)(8)
(7)(8)(9)
(7)(8)(9)
(7)(8)
(7)(8)
(7)(8)
(7)(8)(9)

AS-B-U-UA
AS-B-U-UA
AS-B-UA-U(62 - 102)
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-UA-U(62 - 102)
AS-B-U-UA
U-UA-UE
U-UA-UE
A-AS-ACT-APC-B-U-UA-UE
U-UA-UE
U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-ACT-APC-B-U-UA-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-B-U-UA-UE
AS-B-U-UA
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-B-U-UA
A-AS-ACT-APC
A-AS-ACT-APC

(1)(2) The characteristics are described on the appropriate card.


(3) PX2C6, PX2 panel in multiple 6-piece pack.
(4) Accessoires is not available in the model with Plasmacluster filter
(5) The DSC4 accessory is not compatible with AMP and BC4_5_6 accessories
(6) DSC4 and accessoires VMF-system tray cannot be installed together on a single fan coil.
(7) The VCF/VCFD valve and the BC4 tray cannot be installed together on a single fan coil.
(8) = VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 they are 24V
(9) Only for the BV 1-row coil accessory.

13

Technical data
Mod.

FCX

Vel.

17

22

24

32

34

HEATING PERFORMANCE (2 PIPE CONFIGURATION)


(1)
W
H
2296 2960 3912 5354 5964
Heating capacity (70C)
(1)
W
M
2033 2531 3103 4065 4801
(1)
W
L
1686 1906 2097 3165 3728
(1)
l/h
H
201
260
343
470
523
Water ow rate
(1)
l/h
M
178
222
272
357
421
(1)
l/h
L
148
167
184
278
327
(1)
kPa
H
3
6
4
20
11
Pressure drop
(1)
kPa
M
2
4
3
12
7
(1)
kPa
L
1
3
1
8
5
(2)
W
H
1360 1770 2320 3160 3550
Heating capacity (50C)
(2)
W
M
1200 1510 1840 2400 2860
(2)
W
L
990
1130 1250 2060 2220
(2)
l/h
H
172
258
298
413
482
Water ow rate
(2)
l/h
M
144
210
236
316
392
(2)
l/h
L
112
144
174
267
303
(2)
kPa
H
2
6
3
16
9
(2)
kPa
M
2
5
2
10
7
Pressure drop
(2)
kPa
L
1
2
1
7
4
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
1400 1770
2850
Heating capacity (70C)
(3)
W
M
1200 1510
2450
(3)
W
L
990
1130
2030
(3)
l/h
H
123
155
250
Water ow rate
(3)
l/h
M
105
132
215
(3)
l/h
L
87
99
178
(3)
kPa
H
3
6
16
Pressure drop
(3)
kPa
M
2
5
12
(3)
kPa
L
2
3
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1000 1500 1730 2400 2800
(4)
W
M
840
1220 1370 1840 2280
Total cooling capacity
(4)
W
L
650
840
1010 1550 1760
(4)
W
H
830
1240 1380 1900 2130
(4)
W
M
690
1000 1090 1570 1720
Sensible cooling capacity
(4)
W
L
510
670
760
1110 1250
(4)
l/h
H
172
258
298
413
482
Water ow rate
(4)
l/h
M
144
210
236
316
392
(4)
l/h
L
112
144
174
267
303
(4)
kPa
H
3
6
3
28
14
Pressure drop
(4)
kPa
M
2
5
2
17
10
(4)
kPa
L
1
3
1
13
6
m3/h
H
200
290
290
450
450
Air ow rate
M
160
220
220
350
350
m3/h
L
110
140
140
260
260
m3/h
type
Fans
n
1
1
1
2
2
W
H
35
25
33
44
44
Absorbed power
W
M
29
22
29
33
34
W
L
19
19
25
25
28
Max. input current
(A)
0,16
0,12
0,25
0,21
0,45
(5)
dB(A)
H
45
50
51
48
48
Sound power level
(5)
dB(A)
M
38
43
46
41
41
(5)
dB(A)
L
31
31
35
34
36
(6)
dB(A)
H
37
42
43
40
40
Sound pressure level
(6)
dB(A)
M
30
35
38
33
33
(6)
dB(A)
L
23
23
27
26
28
Water content
l
0,6
0,8
1,0
1,1
1,5
(4R)
3/4"
3/4"
Coil connections
(3R)
1/2"
1/2"
1/2"
(1R)
1/2"
1/2"
1/2"
H
V3
V3
V3
V3
V3
M
V2
V2
V2
V2
V2
Speed connected
L
V1
V1
V1
V1
V1

Power supply

36

42

44

50

54

56

6413
4983
4188
563
437
367
13
10
8
3800
2950
2480
482
370
311
9
7
6

6618
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
15
13
8

8600
6930
5200
754
608
456
22
15
9
4950
4140
3170
765
617
463
23
15
9

8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
604
432
15
11
6

10100
8759
6241
886
768
547
23
18
9
6100
5220
3700
855
743
533
22
17
9

9648
8434
6056
846
740
531
42
33
19
5380
4840
3680
791
662
475
22
20
15

3460
3410
2660
303
299
233
21
20
14

4380
3940
3220
384
346
282
35
30
21

5490
4700
3870
482
412
339
16
12
10

6410
6300
5300
562
553
465
15
14
11

6810
6230
5430
597
547
476
19
16
13

2800
2150
1810
2200
1820
1280
482
370
311
28
17
13
450
350
260

3400
2780
2310
2760
2110
1630
585
478
397
14
10
7
600
460
330

4970
4320
3100
3540
3060
2170
855
743
533
26
21
12
720
600
400

4600
3850
2760
3500
3070
2120
791
662
475
38
28
15
720
600
400

4860
4370
3220
3980
3300
2440
836
752
554
17
14
8
920
720
520

6350
5210
3920
5030
4100
3060
1092
896
674
13
9
6
920
720
520

6910
5000
4290
5680
3780
2970
1189
860
738
22
12
9
1140
930
700

8600
7320
5770
5780
4870
2800
1479
1259
992
30
22
15
1140
930
700

7620
6880
5690
5530
5350
4420
1311
1183
979
37
31
22
1300
1120
900

2
44
33
25
0,21
48
41
34
40
33
26
1,5
3/4"
1/2"
V3
V2
V1

2
57
43
30
0,28
51
44
37
43
36
29
1,5
3/4"
1/2"
V3
V2
V1

2
76
52
38
0,36
56
53
44
48
45
36
1,9
3/4"
V3
V2
V1

2
76
52
38
0,35
56
51
42
48
43
34
1,9
3/4"
1/2"
V3
V2
V1

3
82
61
40
0,40
57
51
42
49
43
34
2,5
3/4"
1/2"
V3
V2
V1

3
91
60
38
0,48
57
51
44
49
43
36
3,4
3/4"
V3
V2
V1

3
106
80
59
0,49
61
56
51
53
48
43
2,5
3/4"
1/2"
V3
V2
V1

3
106
80
59
0,62
61
57
51
53
49
43
3,4
3/4"
V3
V2
V1

3
131
100
80
0,58
66
61
56
58
53
48
2,5
3/4"
1/2"
V3
V2
V1

4450 4190
3590 3510
2690 2510
3300 3000
2640 2540
1960 1790
765
721
617
604
463
432
40
19
27
14
16
8
600
720
460
600
330
400
centrifugal
2
2
57
67
43
46
30
34
0,51
0,35
55
56
50
51
41
42
47
48
42
43
33
34
1,9
1,5
3/4"
3/4"
1/2"
V3
V3
V2
V2
V1
V1
230V/1/50Hz

62

64

82

102

12919 14300 15140 17100 17019


10942 11501 13349 14421 15242
8327 8499 10771 11198 12558
1133 1254 1328 1500 1493
960
1009 1171 1295 1337
730
745
945
982
1101
17
23
21
32
43
12
16
16
23
34
7
9
11
15
24
7500 8400 7960 10200 10000
6430 6800 6860 8600 9000
4880 5040 5200 6700 7440
836
1092 1189 1479 1311
752
896
860
1259 1183
554
674
738
992
979
9
18
21
31
33
7
13
12
23
27
4
8
9
15
19

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperare 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperare 7C; 'T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

14

84

Dimensions and Weight

A
D

ZX accessoires

(standard and increased coil)


FCX_A
FCX_AS
FCX_ACT
FCX_APC

FCX_B
FCX_UA 17-22-32-36-42-50-56 (standard coil)
FCX_UA 24-34-44-54 (increased coil)
FCX_U 62-82-102 (standard coil)
FCX_U 64-84 (increased coil)
FCX_U 62-82-102 (standard coil)

FCX_U 17-22-32-36-42-50-56 (standard coil)


FCX_U 24-34-44-54 (increased coil)
FCX_UE 22-32-42-50 (standard coil)

A
B
C
D

mm
mm
mm
mm
kg

17
563
640
220
105
13

22 / 24
563
750
220
105
15

32/34/36
563
980
220
105
20

42/44
563
1200
220
105
24

50/54/56
563
1200
220
105
24

62/64
688
1320
220
125
34

82/84
688
1320
220
125
34

102
688
1320
220
125
34

Mod FCX (U - UE)


Height
Width
depth
Weight

A
B
C

mm
mm
mm
kg

17
520
640
220
13

22 / 24
520
750
220
15

32/34/36
520
980
220
20

42/44
520
1200
220
24

50/54/56
520
1200
220
24

62/64
590
1320
220
34

82/84
590
1320
220
34

102
590
1320
220
34

Mod FCX (UA)


Height
Width
depth
Weight

A
B
C

mm
mm
mm
kg

17
490
640
220
13

22 / 24
490
750
220
15

32/34/36
490
980
220
20

42/44
490
1200
220
24

50/54/56
490
1200
220
24

Mod FCX (B)


Height
Width
depth
Weight

A
B
C

mm
mm
mm
kg

17
490
640
220
13

22 / 24
490
750
220
15

32/34/36
490
980
220
20

42/44
490
1200
220
24

50/54/56
490
1200
220
24

62 / 64
590
1320
220
34

82 / 84
590
1320
220
34

102
590
1320
220
34

Cod.: SFCXUY.19 / 1501

Mod FCX (A - AS - ACT - APC)


Height with feet
Width
depth
Feet height
Weight (without feet)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293577
www.aermec.com

15

FCXI

Fan coils with Brushless Inverter motor (EC)


Universal and floor installation

Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

FCXI A

housing: RAL 9002


head and feet: RAL 7044

FCXI U

ENERGY SAVINGS OF 50% COMPARED WITH A FAN


COIL WITH TRADITIONAL 3-SPEED MOTOR
VERY QUIET OPERATION
TOTAL COMFORT: REDUCED TEMPERATURE AND
HUMIDITY VARIATIONS IN THE AIR-CONDITIONED
ROOMS
Characteristics
Fan coils with with inverter technology, for heating, cooling and dehumidifying, specific to
work in sensible environment.
Equipped with inverter Brushless motor for an
high effciency and a continuos air flow rate
modulation in order to increased comfort and
guarantee electric saving. The inverter motor
allows a better air temperature regulation on
based on the real indoor envirorement requirements without temperature swinging..
The FCXI are the ideal solution for 2/4-pipe systems
and for tertiary and commercial installations.
Thanks to the availability of different versions, with
front or lower air intake, with standard battery or
increased, for horizontal or vertical installation, it is
easy to choose the optimal solution for any need.

Versions:
FCXI AS: with tall cabinet
FCXI U: with universal cabinet for floor/ ceiling
installation
FCXI ACT: vertical free standing with electronic thermostat
Fan unit with Brushless motor (continuous 0-100%
speed variation)
Full compliance with the accident prevention
standards
Rounded line
Metallic protective cabinet with rustproofing polyester paint
Adjustable air distribution grille, for U versions
Fan coil automatic power-off function with closure
of the air delivery grille, for U versions
Quiet operation

Low loss of charge in the heat exchange batteries


Ease of installation and maintenance
Air filter easy to remove and clean
Extractable shrouds for easy, effective cleaning
Water connections can be reversed during installation phase

Accessories
WMT21: Control panel with electronic thermostat
and LCD monitor. Wall mounting.
PTI2: Control panel with electronic thermostat on
the fan coil installation.
VMF System: the characteristics are described on
the appropriate card.
AMP: Kit for ceiling installation, for versions
FCXI U.
BC: Auxiliary condensate drip tray.
BV: 1-row hot water coil.
The accessory is not available for the 4R models.
DSC4: Condensate drainage device for use when
natural run-off is not possible.
MA: A-type covering cabinet (use tray accessory
BC 4 for FCXI AS, ACT).

16

copper couplings and pipes. For 3/4-row and


MU: U-type covering cabinet (use tray accessory
1-row coils (BV).
BC 5-6 for FCXI U).
VCF_X4: The valve kits are designed for fan coil
PC: Sheet metal panel to close rear of unit.
units with single coil, installed in a 4 pipe system
SE: External air damper with command, FCXI AS
with the "Cooling" and "Heating" circuits totally
and ACT.
separated. The kit consists of 2 valves of 3-way 4
SWAI: Water temperature probe for WMT21 conport connection complete with electro-thermal
trol panels. Cable length L = 2m.
actuators, insulating shells for the valves and asso VMF-SW1: Additional water sensor may be used
ciated hydraulic piping. VCF1X4L Valve kit for left
for 4-pipe system with VMF-E1 and E18 thermohand connection fan coil units. VCF1X4R Valve kit
stats for the maximum control in the cold range
for right hand connection fan coil units. Power
VCF: Kit comprising motorized 3 way valve with
supply: 230V ~ 50Hz.
isolating shell, unions and insulated copper pipes.
For 3/4-row and 1-row coils (BV). Versions with ZX: Feet for floor installations for FCXI AS and ACT
models.
230V and 24V~50Hz power supply.
VCFD: Kit consisting of powered 2-way valve,

Accessories

WMT21
SWAI
VMF-SW1
PTI2
VMF-E18
VMF-E2
VMF-E2D
VMF-E4 / E4D
VMF-E5N / B
AMP
AMP20
4
BC
5
6
122
132
BV
142
162
DSC4
22
23
32
PC
33
42
43
62
20X
30X
SE
40X
80X
1X4L o R
2X4L o R
3X4L o R
41 - 4124
VCF
42 - 4224
43 - 4324
44 - 4424
45 - 4524
1 - 124
2 - 224
VCFD
3 - 324
4 - 424
5
ZX
6

20

24

30

34

36

FCXI
40

44

50

54

56

80

84

(1)(2)

(3)
(3)
(3)
(3)(4)
(3)(4)
(3)(4)
(3)(4)(5)
(3)(4)
(3)
(3)
(3)
(3)(5)

AS - U
AS - U
AS - U
AS - e 80U-84U
AS - U
AS - U
U
AS - U
AS - U
U
U
AS - ACT
U
U
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - ACT
U
AS - ACT
U
AS - ACT
U
AS - U - ACT
AS - ACT
AS - ACT
AS - ACT
AS - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - ACT
AS - ACT

(1)The DSC4 is not compatible with BC4_5_6_8_9 AMP and accessories. The DSC4 accessory is compatible with AMP20 accessory.
(2) The DSC4 and the VMF-system can not be installed simultaneously on the same fancoil
(3) The BC4 accessory is not available for models fitted with VCF / VCFD valve.
(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V
(5) Only for accessory coil BV 1R.

17

Technical data
Mod.
FCXI
Vel.
20
24
30
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
H
2960
3912
5354
Heating capacity (70C)
(1)
W
M
2531
3103
4065
(1)
W
L
1906
2097
3165
(1)
l/h
H
260
343
470
Water ow rate
(1)
l/h
M
222
272
357
(1)
l/h
L
167
184
278
(1)
kPa
H
6
4
20
Pressure drop
(1)
kPa
M
4
3
12
(1)
kPa
L
3
1
8
(2)
W
H
1.770
2.320
3.160
Heating capacity (50C)
(2)
W
M
1.510
1.840
2.400
(2)
W
L
1.130
1.250
2.060
(2)
l/h
H
258
298
413
Water ow rate
(2)
l/h
M
210
236
316
(2)
l/h
L
144
174
267
(2)
kPa
H
6
3
16
Pressure drop
(2)
kPa
M
5
2
10
(2)
kPa
L
2
1
7
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
1.770
2.850
Heating capacity (70C)
(3)
W
M
1.510
2.450
(3)
W
L
1.130
2.030
(3)
l/h
H
155
250
Water ow rate
(3)
l/h
M
132
215
(3)
l/h
L
99
178
(3)
kPa
H
6
16
Pressure drop
(3)
kPa
M
5
12
(3)
kPa
L
3
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1500
1730
2400
Total cooling capacity
(4)
W
M
1.220
1.370
1.840
(4)
W
L
840
1010
1550
(4)
W
H
1240
1380
1900
Sensible cooling capacity
(4)
W
M
1.000
1.090
1.570
(4)
W
L
670
760
1110
(4)
l/h
H
258
298
413
Water ow rate
(4)
l/h
M
210
236
316
(4)
l/h
L
144
174
267
(4)
kPa
H
5,8
3
28
Pressure drop
(4)
kPa
M
5
2
17
(4)
kPa
L
2,5
1
13
m3/h
H
290
290
450
Air ow rate
m3/h
M
220
220
350
m3/h
L
140
140
260
type
Fans
n
1
1
2
W
H
12
12
13
Absorbed power
W
M
8
8
7
W
L
5
5
4
Max. input current
(A)
0,12
0,12
0,21
(5)
dB(A)
H
50
51
48
Sound power level
(5)
dB(A)
M
43
46
41
(5)
dB(A)
L
31
35
34
(6)
dB(A)
H
42
43
40
Sound pressure level
(6)
dB(A)
M
35
38
33
(6)
dB(A)
L
23
27
26

34

36

40

44

50

54

56

80

84

5964
4801
3728
523
421
327
11
7
5
3.550
2.860
2.220
482
392
303
9
7
4

6413
4983
4188
563
437
367
13
10
8
3.800
2.950
2.480
482
370
311
9
7
6

6618
5521
4062
581
484
356
15
11
6
3.960
3.300
2.430
585
478
397
15
13
8

8600
6930
5200
754
608
456
22
15
9
4.950
4.140
3.170
765
617
463
23
15
9

8191
7529
5021
718
660
440
15
13
6
4.870
4.480
3.000
721
604
432
15
11
6

10100
8759
6241
886
768
547
23
18
9
6.100
5.220
3.700
855
743
533
22
17
9

9648
8434
6056
846
740
531
42
33
19
5.380
4.840
3.680
791
662
475
22
20
15

15140
13349
10771
1328
1171
945
21
16
11
7.960
6.860
5.200
1189
860
738
21
12
9

17100
14421
11198
1500
1295
982
32
23
15
10.200
8.600
6.700
1479
1259
992
31
23
15

2.850
2.450
2.030
250
215
178
16
12
8

3.460
3.410
2.660
303
299
233
21
20
14

4.380
3.940
3.220
384
346
282
35
30
21

4.380
3.940
3.220
384
346
282
35
30
21

6.410
6.300
5.300
562
553
465
15
14
11

2800
2.280
1760
2130
1.720
1250
482
392
303
13,8
10
6
450
350
260

2800
2.150
1810
2200
1.820
1280
482
370
311
28
17
12,7
450
350
260

4450
3.590
2690
3300
2.640
1960
765
617
463
40,2
27
16,3
600
460
330

4190
3.510
2510
3000
2.540
1790
721
604
432
19,3
14
7,6
720
600
400

4970
4.320
3100
3540
3.060
2170
855
743
533
25,9
21
11,7
720
600
400

4600
3.850
2760
3500
3.070
2120
791
662
475
38
28
15,1
720
600
400

6910
5.000
4290
5680
3.780
2970
1189
860
738
22
12
9,3
1140
930
700

8600
7.320
5770
5780
4.870
2800
1479
1259
992
29,5
22
14,7
1140
930
700

2
17
9
6
0,28
55
50
41
47
42
33

2
37
20
8
0,35
56
51
42
48
43
34

2
37
20
8
0,35
56
53
44
48
45
36

2
37
20
8
0,35
56
51
42
48
43
34

3
80
40
30
0,49
61
56
51
53
48
43

3
80
40
30
0,49
61
57
51
53
49
43

2
13
7
4
0,21
48
41
36
40
33
28

3400
2.780
2310
2760
2.110
1630
585
478
397
14,3
10
7
600
460
330
centrifugal
2
2
13
17
7
9
4
6
0,21
0,28
48
51
41
44
34
37
40
43
33
36
26
29

H max. speed; M med. speed; L min. speed


Heating performance
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperare 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
Cooling performance (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperare 7C; 'T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

18

Technical data
Mod.
Water content
Coil connections

Work percentage compared to


the conguration signal

FCXI
l
(4R)
(3R)
(1R)
%
%
%

Vel.

20
1
1/2"
1/2"

24
1,11
3/4"
-

30
1,5
1/2"
1/2"

34
1,5
3/4"
-

36
1,48
3/4"
1/2"

40
1,9
3/4"
1/2"

44
1,48
3/4"
-

50
1,9
3/4"
1/2"

54
1,9
3/4"
-

56
2,52
3/4"
1/2"

80
3,4
3/4"
1/2"

84
2,52
3/4"
-

H
M
L

90
84
44

90
84
44

90
84
48

90
84
48

90
84
48

90
82
52

90
82
52

90
86
60

90
86
60

90
86
60

90
84
45

90
84
45

230V/1/50Hz

Power supply

Dimensions (mm)

A
D

ZX (accessoires)

(standard coil and augmented)


FCXI_AS
FCXI_ACT
FCXI_U

FCXI_U 20-30-36-40-50-56
FCXI_U 24-34-44-54

(standard coil)
(augmented coil)

FCXI_U 80
FCXI_U 84

(standard coil)
(augmented coil)

A
B
C
D

mm
mm
mm
mm
kg

20 / 24
563
750
220
105
15

30 / 34 / 36
563
980
220
105
20

40 / 44
563
1200
220
105
24

50 / 54 / 56
563
1200
220
105
24

80 / 84
688
1320
220
125
34

Mod FCXI (U)


Height
Width
Depth
Weight

A
B
C

mm
mm
mm
kg

20 / 24
520
750
220
15

30 / 34 / 36
520
980
220
20

40 / 44
520
1200
220
24

50 / 54 / 56
520
1200
220
24

80 / 84
590
1320
220
34

Cod.: SFCXIUY.06 / 1502

Mod FCXI (AS - ACT)


Height with feet
Width
Depth
Height of feet
Weight (without feet)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

19

DUALJET
Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

Controlled outlet fan coils


Floor installation

White
housing RAL 9002
head and feet RAL 7044

DUALJET: comfort, everywhere


The perception of uneven temperature distribution, especially vertically, is one of the main factors that can
drastically reduce occupants' perceived well-being.
The innovative DUALJET fan coil makes the room more comfortable, by directing the air in such a way as to
provide uniform temperature distribution throughout the room.
In winter, warm air is directed towards the floor; in the summer, cool air is directed towards the ceiling.
Features
Switching the front air outlet or from the top,
using the selector on the unit.
Front outlet for heating operation.
Outlet from the top for cooling operation.
Versions with 3-row coil
(sizes 20, 30, 40, 50)
3-speed ventilating unit
Full compliance with the accident prevention
standards
Rounded line
Metallic protective cabinet with rustproofing
polyester paint

Plastic feet available as accessory


Quiet operation
Low loss of charge in the heat exchange
batteries
Electric motors with permanently inserted
condensers
Ease of installation and maintenance
Air filter easy to remove and clean
Extractable shrouds for easy, effective cleaning
Water connections can be reversed during
installation phase

Control panel and VMF System: The features VCFD: Kit consisting of powered 2-way valve,
copper couplings and pipes. For 4-row, 3-row
are described in the dedicated cards.
and 1-row coils (BV). Versions with 230V and
* VMF-E1D Please contact us.
24V~50Hz power supply.
ZX: Feet for floor mounting
VCF: the kit contains a motorised 3-way valve VCF_X4: The valve kits are designed for fan coil
units with single coil, installed in a 4 pipe syswith insulating shell, plus coupling and pipes
in insulated copper. For 4-row, 3-row and
tem with the "Cooling" and "Heating" circuits
1-row coils (BV). Versions with 230V and
totally separated. The kit consists of 2 valves of
24V~50Hz power supply.
3-way 4 port connection complete with electro-

thermal actuators, insulating shells for the


valves and associated hydraulic piping.
VCF1X4L Valve kit for left hand connection fan
coil units. VCF1X4R Valve kit for right hand
connection fan coil units. Power supply: 230V ~
50Hz.

Controlled outlet fan coils available in 4 sizes:


- Vertical installation:
DUALJET: without control panel but with VMFE0 thermostat, ready for installation on the
network as a Slave unit or as a single or Master
unit if combined with the wired panel
accessories VMF-E4 / VMF-E4D or VMF-E2D
control panel.
All units are compatible with the VMF system
When installing a centralized control VMF-E5B /
VMF-E5N or BMS third party will need to
contact your

Accessories

DUALJET
VMF-E4 VMF-E4D
VMF-E2D
ZX5
VCF41 VCF4124
VCF42 VCF4224
VCFD1 VCFD124
VCFD2 VCFD224
VCF1X4L VCF1X4R
VCF2X4L VCF2X4R

20

20

30

40

50

Technical data
Mod. DUALJET
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
(1)
W
Heating capacity (70C)
(1)
W
(1)
l/h
(1)
l/h
Water ow rate
(1)
l/h
(1)
kPa
(1)
kPa
Pressure drop
(1)
kPa
(2)
W
(2)
W
Heating capacity (50C)
(2)
W
(2)
l/h
(2)
l/h
Water ow rate
(2)
l/h
(2)
kPa
(2)
kPa
Pressure drop
(2)
kPa
cooling PERFORMANCE
(3)
W
(3)
W
Total cooling capacity
(3)
W
(3)
W
(3)
W
Sensible cooling capacity
(3)
W
(3)
l/h
(3)
l/h
Water ow rate
(3)
l/h
(3)
kPa
(3)
kPa
Pressure drop
(3)
kPa
m3/h
m3/h
Air ow rate
m3/h
type
Fans
n
W
W
Absorbed power
W
A
Max. input current
(4)
dB(A)
(4)
dB(A)
Sound power level
(4)
dB(A)
(5)
dB(A)
(5)
dB(A)
Sound pressure level
(5)
dB(A)
l
Water content

Coil connections

Speed connected

Vel.

20

30

40

50

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

2960
2531
1906
260
222
167
6
4
3
1770
1510
1130
258
210
144
6
5
2

5354
4065
3165
470
357
278
20
12
8
3160
2400
2060
413
316
267
16
10
7

9918
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
15
13
8

8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
604
432
15
11
6

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

1500
1220
840
1240
1000
670
258
210
144
5,8
5
2,5
290
220
140

2400
1840
1550
1900
1570
1110
413
316
267
28
17
13
450
350
260

3400
2780
2310
2760
2110
1630
585
478
397
14,3
10
7
600
460
330

4190
3510
2510
3000
2540
1790
721
604
432
19,3
14
7,6
720
600
400

1
25
22
19
0,12
50
43
31
42
35
23
0,79
1/2
V3
V2
V1

2
44
33
25
0,21
48
41
34
40
33
26
1,11
1/2
V3
V2
V1

2
57
43
30
0,28
51
44
37
43
36
29
1,48
3/4
V3
V2
V1

2
67
46
34
0,35
56
51
42
48
43
34
1,48
3/4
V3
V2
V1

Centrifugal
H
M
L
H
M
L
H
M
L

H
M
L

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; 'T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
B

Mod DUALJET
Height
Height with feet
Widht
Depth

20
30
mm
520
520
A
mm
606
606
B mm
750
980
C mm
220
220
D mm
88
88
Weight (1)
kg
15
20
(1) Unit in standard conguration without accessories

40
520
606
1200
220
88
24

50
520
606
1200
220
88
24

B
C

A
A

Code: SDJUY.04/ 1501

Dimensions (mm)

B
C

B
C

A
A
D
D

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

21

Omnia HL

Fan coils
Universal installations for residential applications

Aermec
participate in the EUROVENT program: FCH
the products are present on the site
www.eurovent-certification.com

White colour:
cover: RAL 9002
top and supports: RAL 7044
Grey colour:
cover: FIAT 656
top and supports: RAL 7031

Plasmacluster
(only for Omnia HL PC and PCM)

Features
HL (High Line) fan coils for both horizontal
and vertical installation
4 sizes and 12 versions:
HL: white body with switch
HL M: metallic grey body with switch
HL N: white body with electronic thermostat VMF
HL NM: metallic grey body with electronic thermostat
VMF
HL L: white cabinet with Self-Closing Louver
and electronic thermostat
HL LM: grey cabinet with Self-Closing Louver
and electronic thermostat
HL PC: white body with electronic thermostat

and Plasmacluster filter (factory-mounted only)


HL PCM: metallic grey body with electronic
thermostat and Plasmacluster filter (factorymounted only)
HL S: white body with no on-board controls
VMF System compatible
HL SM: metallic grey body with no on-board
controls. VMF System compatible
3-speed centrifugal fan
Very quiet operation
Aesthetically styled with soft flowing lines
New adjustable air delivery louver
Automatic power-off function with closure of

the air delivery louver


Slim dimensions
Electronic temperature control, automatic fan
speed change, automatic season changeover and
automatic on - off (with electronic thermostat)
Water connections reversibility during installation
Low pressure drop across heat exchanger
Motors with permanently connected condensers
Easy installation and maintenance
Full compliance with safety regulations

SWA: External probe accessory SWA (length


L=6m). It detects the temperature of the room
air if connected to the connector (A) of the
FMT21 panel. The room air temperature probe,
incorporated in the panel, is automatically disabled. It detects the temperature of the water in
the system for ventilation consent if connected
to the connector (W) of the FMT21 panel. Two
SWA probes can be connected simultaneously
to the FMT21 panel.
VCH: Kit comprising motorized 3-way valve,
unions and copper pipes.
VCHD: Kit comprising motorized 2-way
valve, unions and copper pipes.
ZH1: White feet for floor-standing installations
ZH1B: White feet for floor-standing installations with skirting board.
ZH1M: Gray feet for floor-standing installations
ZH1MB: Gray feet for floor-standing installations with skirting board.
Control panels (1) and VMF system (2) : the
characteristics of the control panels are
described on the appropriate card.

Compatibility of accessories
Omnia HL
11 16 26 36 Versions
S-SM
FMT10(1)FMT21(1)
PX2(1) PX2C6(1)
S-SM
PXAE(1)
S-SM
TPF(1)
S-SM
WMT05(1) WMT10(1) S-SM
VMF-E4(2) VMF-E4D(2) S-SM
VMF-E2H(2)
S-SM
VMF-E0(2) VMF-E1(2) S-SM
AMP 10
All except S, SM
BC10 *
All
BC20 *
All
DSC5 *
All
PCH/PCHM
All
SIT3
S-SM
SIT5
S-SM
SW3
S-SM
SWA
S-SM
VCH
All except L, LM
VCHD
All except L, LM
ZH1/ZH1B
All
ZH1M/ZH1MB
All

Accessories
AMP: Kit for wall/ceiling mounting. Standard
on S and SM versions.
BC: Auxiliary condensate drip tray.
BC 10 for vertical installation
BC 20 for horizontal installation
DSC5: Condensate drainage device for use
when natural run-off is not possible. DSC5 is
not compatible BC10 - BC20 accessories.
PCH - PCHM: Back closing panel, white
(PCHM) or gray (PCHM).
SIT 3-5: Thermostat interface cards. They
allow to set up a fancoils network (max. 10)
commanded by a centralised panel (switch or
thermostat).
SIT3: commands the three speeds of the fan
and must be installed on each fancoil of the
network; it receives the commands from the
switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to
two valves (four-pipe systems); it sends the
thermostat commands to the fancoils network.
SW: Water probe which enables automatic
season change-over thanks to the specific
electronic thermostats.

PX2C6, PX2 panel in multiple 6-piece pack.


* = The DSC5 accessory is not compatible BC10 - BC20 accessories.

Main features
Versions compatible with VMF System.
Fan cleaning: Omnia fan coils allow fan
blades to be easily cleaned. It is now possible
to remove the fan volute (it contains the fan
blades) and clean it periodically.
Condensate drip tray cleaning: Thanks to a
new drip tray fitting, it is now easier to clean
it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs
and mould to grow up, in the drip tray
because of the air humidity.

22

Precharged electrostatic filter: Omnia fan


coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure
breathable air to the whole family.
PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level
of pollutants, by decomposing the molecules
that form them. Using a series of electric
shocks, "Plasmacluster" causes the water mol-

ecules present in the air to separate into positive and negative ions. These ions neutralise
the gas pollutant molecules, forming products
that are normally present in clean air. The
result is in the air: you can finally breath
clean, odour-free ionised air.
Silent operation: Thanks to the use of special
centrifugal fans, Omnia fan coils operation is
extremely silent and offers the maximum
acoustic comfort.

Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
(1)
W
Heating capacity (70C)
(1)
W
(1)
l/h
(1)
l/h
Water ow rate
(1)
l/h
(1)
kPa
(1)
kPa
Pressure drop
(1)
kPa
(2)
W
(2)
W
Heating capacity (50C)
(2)
W
(2)
l/h
(2)
l/h
Water ow rate
(2)
l/h
(2)
kPa
(2)
kPa
Pressure drop
(2)
kPa
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(3)
W
(3)
W
Total cooling capacity
(3)
W
(3)
W
(3)
W
Sensible cooling capacity
(3)
W
(3)
l/h
(3)
l/h
Water ow rate
(3)
l/h
(3)
kPa
(3)
kPa
Pressure drop
(3)
kPa
m3/h
m3/h
Air ow rate
m3/h
type
Fans
n
W
W
Absorbed power
W
(A)
Max. input current
(4)
dB(A)
(4)
dB(A)
Sound power level
(4)
dB(A)
(5)
dB(A)
(5)
dB(A)
Sound pressure level
(5)
dB(A)
l
Water content

Coil connections

Vel.

HL 11

HL 16

HL 26

HL 36

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

2010
1460
1060
176
128
93
2
1
1
1150
870
650
144
117
93
2
1
1

2910
2120
1540
255
186
135
4
2
1
1700
1250
930
206
153
122
4
2
2

4620
3830
2890
405
336
253
11
8
5
2750
2240
1670
349
289
220
10
7
4

5940
4870
3530
521
427
310
7,7
5,4
3
3540
2860
2080
487
394
286
16
11
6

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

840
680
540
700
530
390
144
117
93
1,9
1
1
180
120
80

1200
890
710
990
710
540
206
153
122
4,8
3
2
240
160
110

2030
1680
1280
1640
1330
990
349
289
220
11
9
5
350
270
190

2830
2290
1660
2040
1620
1160
487
394
286
18,9
12
7
460
350
240

1
18
12
8
0,09
46
37
31
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1

1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1

2
35
27
24
0,18
48
43
35
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1

2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1

Centrifugal
H
M
L
H
M
L
H
M
L

H
M
L

Speed connected
Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; DT water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Mod Omnia
Height
Widht
Depth
Height with feet
Weight

A
B
C
D
kg

HL 11
600
640
187
93
13,6

HL 16
605
750
189
93
14,6

HL 26
615
980
191
93
17,6

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Cod.: SOHLUY.18 / 1502

Dimensions (mm)
HL 36
623
1200
198
93
20,6

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

23

Omnia UL

Fan coils
Universal installations for residential applications

Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

Plasmacluster
(only for Omnia UL PC)

White colour:
cover: RAL 9002
top and supports: RAL 7044

Features
UL (Universal Line) fan coils for both horizontal and vertical installation
Versions:
UL-S: version without switch, with cabinet.
Compatible with VMF System
UL: version with switch and cabinet
UL-C: version with electronic thermostat and
with cabinet
UL-PC: version with electronic thermostat
and Plasmacluster filter (factory-mounted
only) and cabinet
Versions compatible with VMF System.
Fan cleaning: Omnia fan coils allow fan
blades to be easily cleaned. It is now possible
to remove the fan volute (it contains the fan
blades) and clean it periodically.
Condensate drip tray cleaning: Thanks to a
new drip tray fitting, it is now easier to clean
it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs
and mould to grow up, in the drip tray

because of the air humidity.


Precharged electrostatic filter: Omnia fan
coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure
breathable air to the whole family.
PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level
of pollutants, by decomposing the molecules
that form them. Using a series of electric
shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise
the gas pollutant molecules, forming products
that are normally present in clean air. The
result is in the air: you can finally breath
clean, odour-free ionised air.
Silent operation: Thanks to the use of special
centrifugal fans, Omnia fan coils operation is
extremely silent and offers the maximum

acoustic comfort.
3-speed centrifugal fan
Very quiet operation
Aesthetically styled with soft flowing lines
Adjustable air delivery louver
Automatic power-off function with closure of
the air delivery louver
Slim dimensions
Electronic temperature control, automatic fan
speed change, automatic season changeover
and automatic on - off (with electronic thermostat)
Water connections reversibility during installation
Low pressure drop across heat exchanger
Motors with permanently connected condensers
Easy installation and maintenance
Air filter easy to remove and to clean
Full compliance with safety regulations

Accessories
AMP: Kit for wall/ceiling mounting. Standard
SIT3: commands the three speeds of the fan
on P and S versions.
and must be installed on each fancoil of the
BC: Auxiliary condensate drip tray.
network; it receives the commands from the
BC 10 for vertical installation
switch or from the SIT5 card.
BC 20 for horizontal installation
SIT5: commands the 3 fan speeds and up to
DSC5: Condensate drainage device for use
two valves (four-pipe systems); it sends the
when natural run-off is not possible. DSC5 is
thermostat commands to the fancoils netnot compatible BC10 - BC20 accessories.
work.
GU: Aspiration grille, covers the front space SW: Water probe wich enables automatic
between the stands, does not interfere with
season change-over thanks to the specific
the air filter. Use with ZU stands compulsory.
electronic thermostats.
PCU: Rear cover panel.
SWA: External probe accessory SWA (length L
SIT 3-5: Thermostat interface cards. They
= 6m). It detects the temperature of the room
allow to set up a fancoils network (max. 10)
air if connected to the connector (A) of the
commanded by a centralised panel (switch or
FMT21 panel. The room air temperature
thermostat).
probe, incorporated in the panel, is automatiOmnia UL_S_C_PC
FMT21
PX2 o PX2C6
(1)
PXAE
PXLM
TPF
WMT05
WMT10
VMF-E4 o E4D
VMF-E0 o E1
AMP10
BC10
BC20
DSC5
(2)
SIT3
SIT5
SW3
SWA
VCH
VCHD
ZU

24

vers.
S
S
S
S
S
S
S
S
S
UL-C-PC
all
all
all
S
S
all
S
all
all
UL-S-C-PC

11

16

26

36

cally disabled. It detects the temperature of


the water in the system for ventilation consent
if connected to the connector (W) of the
FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.
VCH: Kit comprising motorized 3-way valve,
unions and copper pipes.
VCHD: Kit comprising motorized 2-way
valve, unions and copper pipes.
ZU: Feet for floor-standing solutions.
Control panels and VMF System: The control
panels are described in a separate document.

(1) PX2C6, PX2 panel in multiple 6-piece pack.


(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.

Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
(1)
W
Heating capacity (70C)
(1)
W
(1)
l/h
(1)
l/h
Water ow rate
(1)
l/h
(1)
kPa
(1)
kPa
Pressure drop
(1)
kPa
(2)
W
(2)
W
Heating capacity (50C)
(2)
W
(2)
l/h
(2)
l/h
Water ow rate
(2)
l/h
(2)
kPa
(2)
kPa
Pressure drop
(2)
kPa
COOLING PERFORMANCE
(3)
W
(3)
W
Total cooling capacity
(3)
W
(3)
W
(3)
W
Sensible cooling capacity
(3)
W
(3)
l/h
(3)
l/h
Water ow rate
(3)
l/h
(3)
kPa
(3)
kPa
Pressure drop
(3)
kPa
m3/h
m3/h
Air ow rate
m3/h
type
Fans
n
W
W
Absorbed power
W
(A)
Max. input current
(4)
dB(A)
(4)
dB(A)
Sound power level
(4)
dB(A)
(5)
dB(A)
(5)
dB(A)
Sound pressure level
(5)
dB(A)
l
Water content

Coil connections

Vel.

UL11

UL16

UL26

UL36

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

2010
1460
1060
176
128
93
2
1
1
1150
870
650
144
117
93
2
1
1

2910
2120
1540
255
186
135
4
2
1
1700
1250
930
206
153
122
4
2
2

4620
3830
2890
405
336
253
11
8
5
2750
2240
1670
349
289
220
10
7
4

5940
4870
3530
521
427
310
7,7
5,4
3
3540
2860
2080
487
394
286
16
11
6

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

840
680
540
700
530
390
144
117
93
1,9
1
1
180
120
80

1200
890
710
990
710
540
206
153
122
4,8
3
2
240
160
110

2030
1680
1280
1640
1330
990
349
289
220
11
9
5
350
270
190

2830
2290
1660
2040
1620
1160
487
394
286
18,9
12
7
460
350
240

1
18
12
8
0,09
46
37
31
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1

1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1

2
35
27
24
0,18
48
43
35
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1

2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1

Centrifugal
H
M
L
H
M
L
H
M
L

H
M
L

Speed connected
Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; 'T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Mod Omnia
Height
Widht
Depth
Height with feet
Weight

A
B
C
D
kg

UL 11
513
640
173
93
12,5

UL 16
513
750
173
93
13,5

UL 26
513
980
173
93
16,5

UL 36
513
1200
173
93
19,5

A
ZU
D

Wall installation
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Cod.: SOULUY.17/ 1502

Dimensions (mm)

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293730
www.aermec.com

Floor installation

25

Omnia Radiant
Fan coils with radiant panel for residential use
Ceiling or floor mounted

Aermec
participate in the EUROVENT
program: FCU
the products are present on the site
www.eurovent-certification.com

LOW TEMPERATURE RADIATION*


VENTILATED HEATING
COOLING - DEHUMIDIFICATION
ENERGY SAVING
LOW OPERATING COST
* Radiant technology under licence

Features
Omnia Radiant and Omnia Radiant Plus
Aermec innovative solutions
In this particular worldwide market evolution,
we are pleased to present to you OMNIA
Radiant, which represents the innovation of the
OMNIA AERMEC series, fan coils especially
designed for residential comfort.
OMNIA Radiant inherits all the advantages of
the OMNIA UL series, and is characterized by
the introduction of the frontal plate for radiant
heating.
OMNIA Radiant Plus is provided with the DC
Brushless electric engine, equipped with the
latest Inverter technology, granting the highest
energy efficiency and able to regulate the air
flow through the continuous fan speed modulation. This allows to achieve up to 60% in energy
saving when compared to the traditional On-Off
fan system, in both air conditioning and heating.
OMNIA Radiant and Radiant Plus offer the following advantages when compared to the traditional systems:
the radiant plate combination the finned
coil allows the best winter comfort with the
lower energy consumption because it provides heating with lower water temperature:
only 45C against the about 65C needed
for the traditional radiator. This not only
increases the comfort for the user, but also
significantly increases the overall efficiency
in case of heat pumps usage;
the fan system allows to quickly reach the
desired temperature, meeting the requirement of a fast start-up;
the unit can be combined other than the
boiler, also to energy saving heat pumps: air
to water, water to water and geothermic
type;
the electrostatic charge filter standard supplied, provides pure and clean air;
during summer Omnia Radiant and Radiant
Plus provide air conditioning and dehumidification in a fast and efficient way in every
room.

26

The four different working modes of Omnia


Radiant annual functioning
Radiant: Heating through radiation, comfortable
and noiseless, is granted by the radiant plate placed on the front of the fan coil cover; if necessary, the triple-fins delivery head can be closed to
increases the heating of the plate, thus maximizing the radiant effect.
Radiant + Natural Convection
With the triple-fins open, heating through natural convection, obtained thanks to the bigger
coil exchange surface, is added to the radiant
heating.
As for the radiant-only mode (see above), the fan
groups are in off mode. This results in acoustic
comfort and energy saving.
Radiant + Forced Convection
The electronic regulation, precise and reliable,
continuously compares the effective indoor temperature with the desired temperature: whenever
the difference between the two should prove to
be too high (e.g. during the heating system startup) the software will lead the fan system start-up.
Start-up is fast and efficient and grants significant
energy savings especially in rooms that are occasionally used.

Radiant

Radiant + Natural Convection

Omnia Radiant during summer provides air


conditioning and dehumidification:
Radiant + Forced Convection
Forced Convection
During summer, Omnia Radiant and Radiant
Plus provide air conditioning and dehumidification for each room of the house in a fast and efficient way. Efficiency and quietness benefit from
the quality that has always characterized the
Omnia series.

Forced Convection

Features of the Omnia Radiant series

Radiant plate

2
3

Switching valve
Water probe

Condensate storage container, hydraulic hoses

2
3

VCHRAD accessory
OMNIA radiant (UL_R) standard features:
- Radiant panel
- Centrifugal fans
- Three-speed motor
- Condensate storage container, hydraulic
hoses
- Switching valve
- Water probe
- Electro-statically preloaded filter
- VMF-thermostat for asynchronous motor
- Compatible with VMF system
OMNIA radiant plus (UL_RI) standard features:
- Radiant panel
- Centrifugal fans
- Electric DC Brushless motor with Inverter
- Condensate storage container, hydraulic hoses
- Water probe
- Switching valve
- Electro-statically preloaded filter
- VMF thermostat for DC Brushless motor
- Compatible with VMF system

Cleaning the fan: The fan blades on the


Omnia Radiant are easy to clean. As a matter of fact, the new versions now offer the
possibility of opening the worm screw of
the fan (the casing that encloses the blades)
to perform routine cleaning.
Electro-statically preloaded filter: The
Omnia Radiant fan coils feature standard
air filters that are electro-statically preloaded. These filters, thanks to their particular
construction, absorb and trap floating dust:
the ideal system to provide clean air for all
the family.
Silent operation: Thanks to special centrifugal fans, Omnia Radiant fan coils are incredibly silent, making them the best buy when
it comes to acoustic comfort, given the total
lack of peak noise. "The heating by radiation
at top speed ensures total silence regime
Note:
The coil had hydraulic hoses on the left and is
not reversible.

Accessories
PCU: Rear closing panel.
ZU: Wedges for floor mount.
GU: Exhaust grille: covers the front space of
the wedges and does not interfere with the
air filter.
VCHRAD: Kit comprising motorized 3-way
valve, unions and copper pipes.
Must be combined with ZU wedges.
VMF System:
Its specs are described in its technical sheet.
Omnia radiant
UL26R
UL36R
PCU
GU
VCHRAD
ZU
VMF system
VMF-E4 (compulsory accessory)
VMF-E4D (compulsory accessory)
VMF-E5B
VMF-E5N

Omnia Radiant plus


UL26RI
UL36RI

25

35

25

35

25

35

25

35

*
*

*
*

* Contact us

27

Technical Data
Mod. UL_R
Heating capacity (70C)

(1)

Heating capacity (50C)


Water ow rate
Water pressure drop
Static heating power (70C)
Static heating power (50C)
Static heating power (35C)

(2)

(3)
(4)
(5)

Total cooling capacity

Sensible cooling capacity


Water ow rate
Water pressure drop
Air ow rate
n Fans
Sound pressure

Sound power
Water contents
Max. motor power
Max. input current
Coil connections (in/out)
Power supply

W (max.)
W (med.)
W (min.)
W
l/h
kPa
W
W
W
W (max.)
W (med.)
W (min.)
W (max.)
W (med.)
W (min.)
l/h
kPa
m3/h (max.)
m3/h (med.)
m3/h (min.)
n.
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
l
W
A
(mm)
V/ph/Hz

26
4620
3830
2890
2750
397
17
650
390
200
2030
1780
1420
1640
1370
1050
349
18
350
270
190
2
39,5
34,5
26,5
48
43
35
0,8
35
0,18
14
230V/1/50Hz

36
5940
4870
3530
3540
511
21
750
450
230
2830
2310
1730
2040
1790
1280
487
22
460
350
240
2
39,5
32,5
25,5
50
41
34
1,1
42
0,22
14
230V/1/50Hz

W (max.)
W (med.)
W (min.)
W
l/h
kPa
W
W
W
W (max.)
W (med.)
W (min.)
W (max.)
W (med.)
W (min.)
l/h
kPa
m3/h (max.)
m3/h (med.)
m3/h (min.)
n.
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
l
W
A
(mm)
V/ph/Hz

26
4620
3830
2890
2750
397
17
650
390
200
2030
1780
1420
1640
1370
1050
349
18
350
270
190
2
39,5
34,5
26,5
48
43
35
0,8
12
0,18
14
230V/1/50Hz

36
5940
4870
3530
3540
511
21
750
450
230
2830
2310
1730
2040
1790
1280
487
22
460
350
240
2
39,5
32,5
25,5
50
41
34
1,1
16
0,22
14
230V/1/50Hz

Mod. UL_RI
Heating capacity (70C)

(1)

Heating capacity (50C)


Water ow rate
Water pressure drop
Static heating power (70C)
Static heating power (50C)
Static heating power (35C)

(2)

Total cooling capacity

Sensible cooling capacity


Water ow rate
Water pressure drop
Air ow rate
n Fans
Sound pressure

Sound power
Water contents
Max. motor power
Max. input current
Coil connections (in/out)
Power supply

(3)
(4)
(5)

Cooling:
Room temperature 27C b.s./19C b.u.; Cold water (in/out) 7C/12C
Heating:
(1) Room temperature 20C b.s.; Hot water (in) 70C; T 10C
(2) Room temperature 20C b.s.; Hot water (in/*) 50C/*C (water ow same as in heating cycle)
(3) Radiant power + natural convection; Hot water (in) 70C (water ow same as in heating cycle)
(4) Radiant power + natural convection; Hot water (in/*) 50C/*C (water ow same as in heating cycle)
(5) Radiant power + natural convection; Hot water (in/*) 35C/*C (water ow same as in heating cycle)

28

Level of sound pressure (A-weighted) measured in the


room with volume V = 85m3 ; reverberation time t = 0.5s;
direction factor Q = 2; distance r = 2.5m

Heating capacity with fan off


UL26R - UL26RI

500

16C
18C
20C
22C
24C
26C

400
300
200
100

Room temperature [C]

Heating capacity [W]

600

0
35

40

45

50

55

60

65

70

Inlet water temperature [C]

UL36R - UL36RI
900

Heating capacity [W]

700

Room temperature [C]

16C
18C
20C
22C
24C
26C

800

600
500
400
300
200
100
0
30

35

40

45

50

55

60

65

70

75

80

Inlet water temperature [C]

Dimensions (mm)

A
ZU
D

Mod OMNIA ULR - ULRI


Height
Width
Depth
Height with ZU (Accessories)
Weight (1)

A
B
C
D

(mm)
(mm)
(mm)
(mm)
(kg)

26
606
980
173
93
20

36
606
1200
173
93
24

Cod.: SOULR_RIUY.03 / 1411

Wall installation

(1) Standard conguration of unit with accessories

Floor installation

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

29

FCX P

Fan coils
Duct installation

Aermec
participate in the EUROVENT
program: FCU
the products are present on the site
www.eurovent-certification.com

Features
Vertical and horizontal installation:
FCX P: Duct installation without cabinet
FCX PPC: Duct installation without cabinet, with
Plasmacluster purifier. Compatible with the VMF
system, or you can request a combination with the
PXAE control panel
FCX PE: Duct installation without cabinet and
with direct expansion coil
FCX PO: with boosted motor
6-speed (3 of which can be selected) up 22 to 82
7-speed (3 of which can be selected) up 62 to 82
FCX PBV: with 3 row coil +1 in a single shoulder,
standard connections (left)
FCX PBVD: with 3 row coil +1 in a single shoul-

der, standard connections (right)


FCX POBV: boosted and with 3 row coil +1 in a
single shoulder, standard connections (left)
FCX POBVD: boosted and with 3 row coil +1 in a
single shoulder, standard connections (right)
For versions with 3 row +1 battery, the battery
is not reversible specify the side of the attacks
at the time of the order.
- Vertical installation:
FCX PV: Duct installation without cabinet
Versions with 3/4-row coil
3-speed ventilating unit
Compatible with the VMF system
Wide range of controls and accessories

VERSION

Quiet operation
Low loss of charge in batteries
Electric motors with permanently inserted
condensers
Ease of installation and maintenance
Air filter easy to remove and clean
Possibility of a residual head for ducting (if
required)
Internal insulation and air filter in fire resistance class 1
Extractable shrouds for easy, effective cleaning
Water connections can be reversed during
installation phase

AVAILABLE SIZES
Versions with 3 row coil

FCX_P
FCX_PV
FCX_PO
FCX_PE
FCX_PPC
FCX_PBV
FCX_PBVD
FCX_POBV
FCX_POBVD

17
17
17
17
-

22
22
22
22
22
22
22
22
22

32
32
32
32
32
32
32
32
32

36
36
36
36
36
36
36
36

42
42
42
42
42
42
42
42
42

50
50
50
50
50
50
50
50
50

56
56
56
56
56
56
56
56

Versions with 4 row coil


62
62
62
62
62
62
62
62
62

82
82
82
82
82
82
82
82
82

102
102
102
102
102
-

24
24
24
24
-

34
34
34
34
-

44
44
44
44
-

54
54
54
54
-

64
64
64
64
-

84
84
84
84
-

Accessories
AMP: Kit for overhang installation.
BC: Auxiliary condensate drip tray.
BV: 1-row hot water coil. Not available for
4-row versions or those with Plasmacluster.
When mounted in place, you must specify the connection side
CHF:VentilCassaforma is a galvanised metal
template that allows you to create a space
directly in the wall for housing the fan coil. (For
FCX P - PV only).
DSC4: Condensate drainage device for use
when natural run-off is not possible.
GA: Intake grille with fixed fins.
GAF: Intake grille with fixed fins and filter.
GM: Delivery grille with adjustable fins.
MA: A-type covering cabinet (use tray accessory BC 4 for FCX AS).
MU: U-type covering cabinet (use the BC 5-6
tray accessory if horizontal, or BC 4 if vertical).
PCR: Galvanised plate protection for the controls and the electrical element.
PA: Plenum suction assembly in galvanised
sheet metal, complete with suction couplings
for circular-section ducts.
PA-F: Plenum suction assembly that allows
intake and delivery on the same side; suitable
for all installations where the machine needs
to be positioned outside the air-conditioned

30

rooms in order to minimise noise levels and


facilitate maintenance operations.
PM: Delivery plenum in galvanised sheet metal,
externally insulated, complete with plastic
delivery couplings for circular section ducts.
RD: Straight delivery coupling for canalisation.
RDA: Straight suction coupling for canalisation.
RP: 90 delivery coupling for canalisation.
RPA: 90 suction coupling for canalisation.
RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater
management). Not available for 4-row versions or those with Plasmacluster.
SE: Manually operated fresh air intake louver.
SIT 3 - 5: Thermostat Interface Cards. They
allow the creation of a network of fan coils
(max. 10) commanded by a central control
panel (selector or thermostat).
SIT3: commands the 3 fan speeds and must
be installed on each fan coil of the network;
receives the commands from the selector or
the SIT5 card.
SIT5: commands the 3 fan speeds and up to 2
valves (four pipes systems); sends the commands of the thermostat to the fan coils network.
SW: water temperature probe that gives the automatic season change feature to electronic thermo-

stats supplied with water-side change over.


SWA: External probe accessory SWA (length L = 6m). It
detects the temperature of air or water depending on its
location in the plant
VCF: the kit contains a motorised 3-way valve
with insulating shell, plus coupling and pipes
in insulated copper. For 4-row, 3-row and
1-row coils (BV). Versions with 230V and
24V~50Hz power supply
VCFD: Kit consisting of powered 2-way valve,
copper couplings and pipes. For 4-row, 3-row
and 1-row coils (BV). Versions with 230V and
24V~50Hz power supply.
VCF_X4: The valve kits are designed for fan
coil units with single coil, installed in a 4
pipe system with the "Cooling" and "Heating"
circuits totally separated. The kit consists of 2
valves of 3-way 4 port connection complete
with electro-thermal actuators, insulating
shells for the valves and associated hydraulic
piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for
right hand connection fan coil units. Power
supply: 230V ~ 50Hz.
ZX: Feet for recessed installation.
Control panels and VMF System: the characteristics are described on the appropriate card.

Accessories
FMT10 FMT21
KTLP
PX PX2 PX2C6
PXAE
PXAR
TF1
TPF
WMT05 WMT06 WMT10
VMF-E4 VMF-E4D
VMF-E0 VMF-E1
AMP
AMP20
4
5
6
BC
8
9
117
122
132
BV
142
162
17
22
CHF
32
42
62
DSC4
17
22
32
GA
42
62
17
22
GAF
32
42
62
17
22
GM
32
42
62
17
22
MA
32
42
62
17
22
MU
32
42
62
17
22
PA
32
42
62
17 F
22 F
PA
32 F
42 F
62 F
1
PCR
2
17
22
PM
32
42
62
17
22
RD
32
42
62
17
22
RDA
32
42
62
17
22
RP
32
42
62
17
22
RPA
32
42
62
17
22
32
RX
42
52
62

FCX Fan Coil


36
42
44

17

22

24

32

34

50

54

56

62

64

82

84

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

(1)

(2)

102 Versions

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV-PPC

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

(3)

P-PE-PO-PV
P-PE-PO-PPC
P-PE-PO-PPC
FCX P-PV+ MA
FCX P + MU
FCX P + MU
P-PE-PO-PPC
P-PE-PO-PPC
P-PE-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PV
P-PV
P-PV
P-PV
P-PV
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PPC
P-PE-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV

31

Accessories
SE

SIT

17
15X
20X
30X
40X
80X
3
5

(4)
(4)
(4)
(4)
(4)

SW3
SWA

VCF

VCFD
ZX

1X4L - 1X4R
2X4L - 2X4R
3X4L - 3X4R
(5)
41 - 4124
(5)
42 - 4224
(5)
43 - 4324
(5)(6)
44 - 4424
(5)
45 - 4524
(5)
1 - 124
(5)
2 - 224
(5)
3 - 324
(5)(7)
4 - 424
7
8

22

24

32

34

FCX Fan Coil


36
42
44

50

54

56

62

64

82

84

102 Versions
P-PE-PV
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV

P-PE-PO-PV-PPC

P-PO-PV

P-PO-PV
P-PO-PV
P-PO-PV

P-PO-PV
P-PO-PV-PPC
P-PO-PV-PPC

P-PO-PV-PPC
P-PO-PV

P-PO-PV
P-PO-PV-PPC
P-PO-PV-PPC

P-PO-PV-PPC

P-PO-PV
P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

(1) the characteristics are described on the appropriate card.


(2) Accessories and BC4 VCF can not be mounted at the same time
(3) DSC4 is incompatible with the accessory AMP and BC Auxiliary condensate
drip tray

(4) The accessory SE require pairing with ZX


(5) 24 Volt
(6) Only for the BV1-row coil accessory

Technical data
Mod. FCX_P / FCX_PO
Vel.
17
22
24
32
34
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
H
2296 2960 3912 5354 5964
Heating capacity (70C)
(1)
W
M
2033 2531 3103 4065 4801
(1)
W
L
1686 1906 2097 3165 3728
(1)
l/h
H
201
260
343
470
523
Water ow rate
(1)
l/h
M
178
222
272
357
421
(1)
l/h
L
148
167
184
278
327
(1)
kPa
H
3
6
4
20
11
Pressure drop
(1)
kPa
M
2
4
3
12
7
(1)
kPa
L
1
3
1
8
5
(2)
W
H
1360 1770 2320 3160 3550
Heating capacity (50C)
(2)
W
M
1200 1510 1840 2400 2860
(2)
W
L
990
1130 1250 2060 2220
(2)
l/h
H
172
258
298
413
482
Water ow rate
(2)
l/h
M
144
210
236
316
392
(2)
l/h
L
112
144
174
267
303
(2)
kPa
H
2
6
3
16
9
(2)
kPa
M
2
5
2
10
7
Pressure drop
(2)
kPa
L
1
2
1
7
4
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
1400 1770
2850
Heating capacity (70C)
(3)
W
M
1200 1510
2450
(3)
W
L
990
1130
2030
(3)
l/h
H
123
155
250
Water ow rate
(3)
l/h
M
105
132
215
(3)
l/h
L
87
99
178
(3)
kPa
H
3
6
16
Pressure drop
(3)
kPa
M
2
5
12
(3)
kPa
L
2
3
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1000 1500 1730 2400 2800
Total cooling capacity
(4)
W
M
840
1220 1370 1840 2280
(4)
W
L
650
840
1010 1550 1760
(4)
W
H
830
1240 1380 1900 2130
Sensible cooling capacity
(4)
W
M
690
1000 1090 1570 1720
(4)
W
L
510
670
760
1110 1250
(4)
l/h
H
172
258
298
413
482
Water ow rate
(4)
l/h
M
144
210
236
316
392
(4)
l/h
L
112
144
174
267
303
(4)
kPa
H
2,6
5,8
3
28
13,8
Pressure drop
(4)
kPa
M
2
5
2
17
10
(4)
kPa
L
1,4
2,5
1
13
6
m3/h
H
200
290
290
450
450
m3/h
Air ow rate
M
160
220
220
350
350
L
110
140
140
260
260
m3/h
type
Fans
n
1
1
1
2
2
W
H
35
25
33
44
44
Absorbed power
W
M
29
22
29
33
34
W
L
19
19
25
25
28

32

36

42

44

50

54

56

6413
4983
4188
563
437
367
13
10
8
3800
2950
2480
482
370
311
9
7
6

6618
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
15
13
8

8600
6930
5200
754
608
456
22
15
9
4950
4140
3170
765
617
463
23
15
9

8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
604
432
15
11
6

10100
8759
6241
886
768
547
23
18
9
6100
5220
3700
855
743
533
22
17
9

9648
8434
6056
846
740
531
42
33
19
5380
4840
3680
791
662
475
22
20
15

3460
3410
2660
303
299
233
21
20
14

4380
3940
3220
384
346
282
35
30
21

5490
4700
3870
482
412
339
16
12
10

6410
6300
5300
562
553
465
15
14
11

6810
6230
5430
6809
6232
5428
19
16
13

2800
2150
1810
2200
1820
1280
482
370
311
28
17
12,7
450
350
260

3400
2780
2310
2760
2110
1630
585
478
397
14,3
10
7
600
460
330

4970
4320
3100
3540
3060
2170
855
743
533
25,9
21
11,7
720
600
400

4600
3850
2760
3500
3070
2120
791
662
475
38
28
15,1
720
600
400

4860
4370
3220
3980
3300
2440
836
752
554
17,3
14
8,3
920
720
520

6350
5210
3920
5030
4100
3060
1092
896
674
13
9
5,5
920
720
520

6910
5000
4290
5680
3780
2970
1189
860
738
22
12
9,3
1140
930
700

8600
7320
5770
5780
4870
2800
1479
1259
992
29,5
22
14,7
1140
930
700

7620
6880
5690
5530
5350
4420
1311
1183
979
37,3
31
22
1300
1.120
900

2
44
33
25

2
57
43
30

2
76
52
38

2
76
52
38

3
82
61
40

3
91
60
38

3
106
80
59

3
106
80
59

3
131
100
80

4450 4190
3590 3510
2690 2510
3300 3000
2640 2540
1960 1790
765
721
617
604
463
432
40,2
19,3
27
14
16,3
7,6
600
720
460
600
330
400
centrifugal
2
2
57
67
43
46
30
34

62

64

82

84

102

12919 14300 15140 17100 17019


10942 11501 13349 14421 15242
8327 8499 10771 11198 12558
1133 1254 1328 1500 1493
960
1009 1171 1295 1337
730
745
945
982
1101
17
23
21
32
43
12
16
16
23
34
7
9
11
15
24
7500 8400 7960 10200 10000
6430 6800 6860 8600 9000
4880 5040 5200 6700 7440
836
1092 1189 1479 1311
752
896
860
1259 1183
554
674
738
992
979
9
18
21
31
33
7
13
12
23
27
4
8
9
15
19

Mod. FCX_P / FCX_PO

Vel.
(P)
(PO)
(5)
(5)
(5)
(6)
(6)
(6)
(5)
(6)

Max input current


Sound power level (P)

Sound pressure level (P)


Sound power level (PO)
Sound pressure level (PO)
Water content
Coil connections

Speed connected

(A)
(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
l
(4R)
(3R)
(1R)
P
P
P

17
0,16
45
38
31
37
30
23
0,58
1/2"
1/2"
V3
V2
V1

H
M
L
H
M
L
H
H

H
M
L

22
0,12
0,25
50
43
31
42
35
23
58
50
0,79
1/2"
1/2"
V3
V2
V1

24
0,25
0,25
51
46
35
43
38
27
58
50
1
3/4"
V3
V2
V1

32
0,21
0,45
48
41
34
40
33
26
53
44
1,11
1/2"
1/2"
V3
V2
V1

34
0,45
0,45
48
41
36
40
33
28
53
44
1,5
3/4"
V3
V2
V1

36
0,21
0,45
48
41
34
40
33
26
53
44
1,5
3/4"
1/2"
V3
V2
V1

42
0,28
0,51
51
44
37
43
36
29
59
50
1,48
3/4"
1/2"
V3
V2
V1

Power supply

44
50
0,51
0,35
0,51
0,36
55
56
50
51
41
42
47
48
42
43
33
34
59
59
50
51
1,9
1,48
3/4"
3/4"
1/2"
V3
V3
V2
V2
V1
V1
230V/1/50Hz

54
0,36
0,36
56
53
44
48
45
36
59
51
1,9
3/4"
V3
V2
V1

56
0,35
0,36
56
51
42
48
43
34
59
51
1,9
3/4"
1/2"
V3
V2
V1

62
0,4
0,48
57
51
42
49
43
34
62
54
2,52
3/4"
1/2"
V3
V2
V1

64
0,48
0,48
57
51
44
49
43
36
62
54
3,4
3/4"
V3
V2
V1

82
0,49
0,62
61
56
51
53
48
43
64
56
2,52
3/4"
1/2"
V3
V2
V1

84
0,62
0,62
61
57
51
53
49
43
64
56
3,4
3/4"
V3
V2
V1

102
0,58
66
61
56
58
53
48
2,52
3/4"
1/2"
V3
V2
V1

H max. speed; M med. speed; L min. speed


Heating mode
FCX2250
2 pipes system configuration
Speed
V1 V2 V3 V4 V5 V6
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
2 pipes system configuration (EUROVENT)
L6 L5 L4 L3 L2 L1 motor connected
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
V1 V2 V3 V4 V5 V6 V7
(3)Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
L7 L6 L5 L4 L3 L2 L1
Cooling mode (EUROVENT)
FCX6282
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation
available on the website www.aermec.com

Dimensions (mm)

FCX_P (standard coil/augmented coil)


C
D

Mod FCX_P
Height
Width

Depth
Weight

A
B

A
B*
C
kg

17
453
452
412
216
11

22 /24
453
562
522
216
13

32/34/36
453
793
753
216
18

42/44
453
1013
973
216
22

50/54/56
453
1013
973
216
22

62/64
558
1147
1122
216
33

82/84
558
1147
1122
216
33

102
558
1147
1122
216
33

50/54/56
891
41
101
74
49
144
260

62/64
1102
41
107
68
32
253
273

82/84
1102
41
107
68
32
253
273

102
1102
41
107
68
32
253
273

* Overall dimensions
FCX_P 20-30-36-40-50-56
FCX_P 24-34-44-54

(standard coil)
(augmented coil)

9x20

H
I

388

40

(standard coil)
(augmented coil)
B

9x20

H
I

350

98

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

E
F
G
H
I
L
M

17
330
41
101
74
49
144
260

22/24
440
41
101
74
49
144
260

32/34/36
671
41
101
74
49
144
260

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

42/44
891
41
101
74
49
144
260

33

Cod.: SFCXPUY.16 / 1401

FCX_P 80
FCX_P 84

FCXI P

Fan coils with Brushless Inverter motor (EC)


In-duct installation


hZKsEdW
&,&W,
d      


ELECTRIC SAVING EQUAL TO 50% COMPARED TO A


FAN COIL WITH 3-SPEED MOTOR
FULLY SILENT FUNCTIONING
FULL COMFORT: REDUCED TEMPERATURE AND
RELATIVE HUMIDITY OSCILLATIONS
Features
Recessed fan coils with inverter technology, for
heating, cooling and dehumidifying, specific to
work in sensible environment.
Equipped with inverter Brushless motor for an
high effciency and a continuos air flow rate
modulation in order to increased comfort and
guarantee electric saving. The inverter motor
allows a better air temperature regulation on
based on the real indoor envirorement requirements without temperature swinging.
The FCXI P are the ideal solution for 2/4-pipe systems and for tertiary and commercial installations.

Versions:
FCXI P: wall/ceiling mounted without cabinet
FCXI PBV: wall/ceiling mounted without cabinet
with double circuit coil for 4-pipe system with
standard connections (left)
FCXI PBVD: wall/ceiling mounted without cabinet
with double circuit coil for 4-pipe system with
right connections
The hydraulic connections of the BV and BVD
versions, up to size 56, are not reversible during
installation. Specify the connection side when
placing the order.
Brushless motor with 0-100% speed continuous
variation to guarantee best performance at very
low sound level
Centrifugal fan designed to guarantee continu-

ous modulation of the air flow rate and to


increase comfort and electric saving.
Unit with standard coil (2080)
Unit with larger coil (2484)
Low pressure drop
Air filter with easy extraction and cleaning
Removable augers for easy and effective cleaning
Reversibility of the hydraulic connections in the
installation phase
A specific wall-control range is available for the
FCXI P. Choose between these panels for simple
and complete regulation. Refer to the specific
sheet for further details.

Accessories
WMT21: Electronic thermostat with LCD display (wall
installation).
SWAI: Water temperature probe for WMT21 electronic thermostat.
VMF System: Find the features in the specific sheets.
AMP: Kit for wall/ceiling mounted installation.
BC: Auxiliary condensate drip tray.
BV: Hot water coil with one row. It is not available
for versions with 4 rows or with Plasmacluster.
Specify the connection side in case of in-site
assembly.
PMZ: Plenum with motorised dampers (refer to the
specific sheet for further details).
CHF: The VentilCassaforma is a galvanised sheet
steel template, for P versions, which allows you to
obtain a space for housing the fan coil, directly in
the wall.
DSC4: Device for draining condensate.
GA: Intake grid with fixed louvers.
GAF: Intake grid with fixed louvers with filter.

34

GM: Flow grid with adjustable louvers.


VCF: Kit made up of 3-way motorised valves with
MA: Protective cabinet, type A (use BC 4 tray
insulating shell, insulated copper fittings and
accessory).
pipes. For 4, 3, and 1-row coils (BV) Versions with
MU: Protective cabinet, type U (use BC 5-6 tray
230V and 24V~50Hz power supply.
accessory if horizontal or use BC 4 if vertical).
VCFD: Kit composed of 2-way motorised valve
PA: Galvanised sheet steel intake plenum
and copper pipes and connections. For 4, 3, and
equipped with intake fittings for circular section
1-row coils (BV) Versions with 230V and
ducts.
24V~50Hz power supply.
PA-F: Intake plenum, which allows recovery and Control panels and VMF System:
flow on the same side. It is suitable for all those
Find the features in the specific sheets.
installations outside air-conditioned rooms, in
order to minimise noise and facilitate maintenance
operations.
PM: Galvanised sheet steel flow plenum, externally insulated, equipped with plastic flow fittings for
ducts and circular sections.
RD: Straight flow fitting for ducting.
RDA: Straight intake fitting for ducting.
RP: 90 flow fitting for ducting.
RPA: 90 intake fitting for ducting.
SE: External air damper with manual control.

Accessories
FCXI_P

20

24

30

34

36

40

44

50

54

56

80

84

WMT21
SWAI
AMP
AMP20

BC

BV

CHF

4
5
6
8
9
122
132
142
162
22
32
42
62

GAF

GM

MA

MU

PA

PA

PM

RD

RDA

RP

RPA

SE

VCF

VCFD
ZX

22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22F
32F
42F
62F
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
20X
30X
40X
80X
1X4L - 1X4R
2X4L - 2X4R
3X4L - 3X4R
41 - 4124
42 - 4224
43 - 4324
44 - 4424
45 - 4524
1 - 124
2 - 224
3 - 324
4 - 424
7
8

(1)(2)

DSC4
GA

(3)
(3)
(3)
(3)(4)
(3)(4)
(3)(4)
(3)(4)(5)
(3)(4)
(3)
(3)
(3)
(3)(5)

P
P
P
P
(P+MA)
(P+MU)
(P+MU)
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

(1) The DSC4 accessory is not compatible with the BC4_5_6_8_9 trays and AMP installation brackets. It is compatible only with AMP20.
(2) DSC4 and the VMF-system accessories cannot be installed simultaneously on the same fan coil
(3) The VCF / VCFD valves and the BC4 tray cannot be installed simultaneously on the same fan coil
(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V
(5) For BV coil with 1 row or for PBV/PBVD versions.

35

Technical data (Eurovent FCH)


Mod. FCXI_P without static pressure
Speed
20
24
30
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
H
2960
3912
5354
Thermal power (70C)
(1)
W
M
2531
3103
4065
(1)
W
L
1906
2097
3165
(1)
l/h
H
260
343
470
Water ow rate
(1)
l/h
M
222
272
357
(1)
l/h
L
167
184
278
(1)
kPa
H
6
4
20
pressure drops
(1)
kPa
M
4
3
12
(1)
kPa
L
3
1
8
(2)
W
H
1,770
2,320
3,160
Thermal power (50C)
(2)
W
M
1,510
1,840
2,400
(2)
W
L
1,130
1,250
2,060
(2)
l/h
H
258
298
413
Water ow rate
(2)
l/h
M
210
236
316
(2)
l/h
L
144
174
267
6
3
16
(2)
kPa
H
(2)
kPa
M
5
2
10
pressure drops
2
1
7
(2)
kPa
L
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
1,770
2,850
Thermal power (70C)
(3)
W
M
1,510
2,450
(3)
W
L
1,130
2,030
(3)
l/h
H
155
250
Water ow rate
(3)
l/h
M
132
215
(3)
l/h
L
99
178
(3)
kPa
H
6
16
Pressure drops
(3)
kPa
M
5
12
(3)
kPa
L
3
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1500
1730
2400
Total cooling capacity
(4)
W
M
1,220
1,370
1,840
(4)
W
L
840
1010
1550
(4)
W
H
1240
1380
1900
(4)
W
M
1,000
1,090
1,570
Sensitive cooling capacity
(4)
W
L
670
760
1110
(4)
l/h
H
258
298
413
Water ow rate
(4)
l/h
M
210
236
316
(4)
l/h
L
144
174
267
5.8
3
28
(4)
kPa
H
5
2
17
(4)
kPa
M
Water pressure drops
(4)
kPa
L
2.5
1
13
m3/h
H
290
290
450
Air ow rate
m3/h
M
220
220
350
m3/h
L
140
140
260
type
Centrifugal
n
1
1
2
W
H
12
12
13
Input power
W
M
8
8
7
W
L
5
5
4
Maximum input current
(A)
0.12
0.12
0.21
(5)
dB(A)
H
50
51
48
Sound power level
(5)
dB(A)
M
43
46
41
(5)
dB(A)
L
31
35
34
42
43
40
(6)
dB(A)
H
35
38
33
(6)
dB(A)
M
Sound pressure level
(6)
dB(A)
L
23
27
26
Water content
l
0.79
1
1.11
(4R)
3/4"
(3R)
1/2"
1/2"
Coil connections
(1R)
1/2"
1/2"
%
H
90
90
90
Work percentage compared to
M
84
84
84
%
the conguration signal
%
L
44
44
48
Electric power supply

34

36

40

44

50

54

56

80

84

5964
4801
3728
523
421
327
11
7
5
3,550
2,860
2,220
482
392
303
9
7
4

6413
4983
4188
563
437
367
13
10
8
3,800
2,950
2,480
482
370
311
9
7
6

6618
5521
4062
581
484
356
15
11
6
3,960
3,300
2,430
585
478
397
15
13
8

8600
6930
5200
754
608
456
22
15
9
4,950
4,140
3,170
765
617
463
23
15
9

8191
7529
5021
718
660
440
15
13
6
4,870
4,480
3,000
721
604
432
15
11
6

10100
8759
6241
886
768
547
23
18
9
6,100
5,220
3,700
855
743
533
22
17
9

9648
8434
6056
846
740
531
42
33
19
5,380
4,840
3,680
791
662
475
22
20
15

15140
13349
10771
1328
1171
945
21
16
11
7,960
6,860
5,200
1189
860
738
21
12
9

17100
14421
11198
1500
1295
982
32
23
15
10,200
8,600
6,700
1479
1259
992
31
23
15

3,460
3,410
2,660
303
299
233
21
20
14

4,380
3,940
3,220
384
346
282
35
30
21

6,410
6,300
5,300
562
553
465
15
14
11

2800
2,280
1760
2130
1,720
1250
482
392
303
13.8
10
6
450
350
260

2800
2,150
1810
2200
1,820
1280
482
370
311
28
17
12.7
450
350
260

4450
3,590
2690
3300
2,640
1960
765
617
463
40.2
27
16.3
600
460
330

4190
3,510
2510
3000
2,540
1790
721
604
432
19.3
14
7.6
720
600
400

4970
4,320
3100
3540
3,060
2170
855
743
533
25.9
21
11.7
720
600
400

4600
3,850
2760
3500
3,070
2120
791
662
475
38
28
15.1
720
600
400

6910
5,000
4290
5680
3,780
2970
1189
860
738
22
12
9.3
1140
930
700

8600
7,320
5770
5780
4,870
2800
1479
1259
992
29.5
22
14.7
1140
930
700

2
17
9
6
0.28
55
50
41
47
42
33
1.9
3/4"
90
82
52

2
37
20
8
0.35
56
51
42
48
43
34
1.48
3/4"
1/2"
90
86
60

2
37
20
8
0.35
56
53
44
48
45
36
1.9
3/4"
90
86
60

2
37
20
8
0.35
56
51
42
48
43
34
1.9
3/4"
1/2"
90
86
60

3
80
40
30
0.49
61
56
51
53
48
43
2.52
3/4"
1/2"
90
84
45

3
80
40
30
0.49
61
57
51
53
49
43
3.4
3/4"
90
84
45

2
13
7
4
0.21
48
41
36
40
33
28
1.5
3/4"
90
84
48

3400
2,780
2310
2760
2,110
1630
585
478
397
14.3
10
7
600
460
330
centrifugal
2
2
13
17
7
9
4
6
0.21
0.28
48
51
41
44
34
37
40
43
33
36
26
29
1.5
1.48
3/4"
3/4"
1/2"
1/2"
90
90
84
82
48
52
230V/1/50Hz

H maximum speed; M medium speed; L minimum speed


Heating
2-pipe system configuration
(1) Ambient air temperature 20C d.b.; Inlet water temperature 70C; 'T water 10C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20C d.b.; Inlet water temperature 50C; Water flow rate the same as in Cooling mode
4-pipe system configuration with additional heat exchanger
(3) Ambient air temperature 20C d.b.; Inlet water temperature 70C; 'T water 10C
Cooling (EUROVENT)
(4) Ambient air temperature 27C d.b./19C w.b.; Inlet water temperature 7C; 'T water 5C
(5) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard
(6) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

36

Technical data (Eurovent FCPH)

H maximum speed; M medium speed; L minimum speed


Heating
2-pipe system configuration
(1) Ambient air temperature 20C d.b.; Inlet water temperature 70C; 'T
water 10C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20C d.b.; Inlet water temperature 50C; Water
flow rate the same as in Cooling mode
4-pipe system with additional heat exchanger (EUROVENT)
(3) Ambient air temperature 20C d.b.; Inlet water temperature 70C; 'T
water 10C
Cooling (EUROVENT)
(4) Ambient air temperature 27C d.b./19C w.b.; Inlet water temperature
7C; 'T water 5C
(5) Sound power based on the measurements carried out in accordance with
Eurovent 8/2 standard
(6) Sound pressure level (A weighted) measured in environment with volume
V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance
r=2.5m
Aermec reserves the right to make all the modifications deemed
necessary for improving the product, including technical data.

34

36

40

44

50

54

56

80

84

5600
5262
3442
491
462
302
8
7
3
3331
3129
2039
459
429
266
7
6
3

4730
4420
3154
415
388
277
14
12
7
2801
2620
1858
364
343
221
11
10
4

6852
6499
4764
601
570
418
13
12
7
4050
3850
2800
519
485
330
10
9
4

7610
7056
4777
668
619
419
18
15
8
4550
4219
2856
678
629
424
18
16
8

7815
7531
5534
686
661
485
12
12
7
4650
4480
3350
654
631
464
12
10
10

9106
8759
6375
799
768
559
19
18
10
5429
5222
3802
772
743
544
18
17
10

7815
7531
5534
686
661
485
12
12
7
4657
4488
3297
657
635
465
12
11
6

11960
11144
6521
1049
978
572
14
12
5
7000
6500
3800
901
836
487
11
9
4

12623
11635
6618
1107
1021
581
18
16
6
7542
6954
3965
1.110
1.029
611
18
16
6

2750
2640
1940
241
232
170
26
24
14

3210
3070
2430
276
264
209
18
17
11

4090
3990
3280
352
343
282
31
31
22

4090
3990
3280
352
343
282
31
31
22

6100
5700
3530
525
490
304
12
10
5

2671
2495
1544
2035
1898
1042
459
429
266
13
11
5
424
390
225

2117
1996
1284
1665
1551
968
364
343
221
26
24
11
424
390
225

3942
3656
2468
2908
2690
1794
678
629
424
32
28
14
515
470
300

3800
3670
2700
2880
2770
2030
654
631
464
16
15
9
630
600
410

4488
4320
3165
3184
3061
2217
772
743
544
22
20
12
630
600
410

3821
3692
2704
2837
2756
2061
657
635
465
16
15
9
630
600
410

5240
4860
2830
3930
3640
2090
901
836
487
13
12
4
799
730
405

6456
5981
3552
4270
3944
2311
1110
1029
611
18
15
6
799
730
405

2
59
50
16
40
31
10

2
59
50
16
40
31
10

3020
2820
1920
2310
2150
1450
519
485
330
12
10
5
515
470
300
centrifugal
2
60
50
20
48
38
16

2
60
50
20
48
38
16

2
55
50
23
60
50
18

2
55
50
23
60
50
18

2
55
50
23
60
50
18

3
60
50
15
78
61
23

3
60
50
15
78
61
23

52
50
36
48
46
32
1,5
3/4"
90
84
48

52
50
36
48
46
32
1,5
3/4"
1/2"
90
84
48

57
55
45
53
51
41
1,48
3/4"
1/2"
90
86
60

57
55
45
53
51
41
1,9
3/4"
90
86
60

57
55
45
53
51
41
1,9
3/4"
1/2"
90
86
60

58
55
38
54
51
34
2,52
3/4"
1/2"
90
84
45

58
55
38
54
51
34
3,4
3/4"
90
84
45

55
55
53
53
43
43
51
51
49
49
39
39
1,48
1,9
3/4"
3/4"
1/2"
90
90
82
82
52
52
230V/1/50Hz

Dimension and weight data


C
D

A
B

Mod FCXI_P
Height
Width
Depth
Weight

20 /24

30/34 /36

40/44

50/54/ 56

mm

453

453

453

453

80/84
558

B*

mm

562

793

1013

1013

1147

mm

522

753

973

973

1122

mm

216

216

216

216

216

kg

13

18

22

22

33

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

37

Code: SFCXIPUY.00 / 1501

Mod. FCXI_P with static pressure


Speed
20
24
30
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
2772
3611
4730
(1)
W
H
Thermal power (70C)
(1)
W
M
2665
3426
4420
(1)
W
L
1754
1968
3154
243
317
415
(1)
l/h
H
Water ow rate
(1)
l/h
M
234
301
388
(1)
l/h
L
154
173
277
(1)
kPa
H
5
4
14
pressure drops
(1)
kPa
M
5
3
12
(1)
kPa
L
2
1
7
(2)
W
H
1640
2136
2700
Thermal power (50C)
(2)
W
M
1600
2026
2560
(2)
W
L
1000
1171
1810
232
267
365
(2)
l/h
H
Water ow rate
(2)
l/h
M
220
253
342
(2)
l/h
L
131
162
222
(2)
kPa
H
5
3
6
(2)
kPa
M
5
2
6
pressure drops
(2)
kPa
L
2
1
5
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
1670
2750
(3)
W
H
Thermal power (70C)
(3)
W
M
1620
2640
(3)
W
L
1120
1940
144
237
(3)
l/h
H
Water ow rate
(3)
l/h
M
139
227
(3)
l/h
L
96
167
(3)
kPa
H
6
26
Pressure drops
(3)
kPa
M
6
24
(3)
kPa
L
3
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
1350
1555
2120
(4)
W
H
(4)
W
M
1280
1469
1990
Total cooling capacity
(4)
W
L
760
940
1290
(4)
W
H
1130
1243
1640
Sensitive cooling capacity
(4)
W
M
1070
1173
1540
(4)
W
L
590
690
980
232
267
365
(4)
l/h
H
Water ow rate
(4)
l/h
M
220
253
342
(4)
l/h
L
131
162
222
5
3
26
(4)
kPa
H
Water pressure drops
(4)
kPa
M
4
2
23
(4)
kPa
L
2
1
11
3
257
257
424
m /h
H
3
Air ow rate
m /h
M
240
240
390
m3/h
L
123
123
225
type
Centrifugal
n
1
1
2
H
57
57
59
Pa
Pa
M
50
50
50
Useful static pressure
Pa
L
14
14
16
30
30
40
W
H
Input power
W
M
25
25
31
W
L
8
8
10
Maximum input current
(A)
(5)
dB(A)
H
58
58
52
Sound power level
(5)
dB(A)
M
57
57
50
(Inlet+radiator)
(5)
dB(A)
L
37
37
36
(6)
dB(A)
H
54
54
48
Sound power level
(6)
dB(A)
M
53
53
46
(outlet)
(6)
dB(A)
L
33
33
32
Water content
l
0,79
1
1,11
(4R)
3/4"
(3R)
1/2"
1/2"
Coil connections
(1R)
1/2"
1/2"
%
H
90
90
90
Work percentage compared to
M
84
84
84
%
the conguration signal
%
L
44
44
48
Electric power supply

Omnia UL

Fan coils
Ceiling installations

Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

Features
UL (Universal Line) fan coils for both horizontal and vertical installation
Versions:
UL-P Without cabinet for ceiling installation
Fan cleaning: Omnia fan coils allow fan
blades to be easily cleaned. It is now possible
to remove the fan volute (it contains the fan
blades) and clean it periodically.
Condensate drip tray cleaning: Thanks to a
new drip tray fitting, it is now easier to clean
it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs
and mould to grow up, in the drip tray
because of the air humidity.
Precharged electrostatic filter: Omnia fan
coils have, as standard, precharged electrostatic filters. These filters, thanks to their spe-

cial execution, attracts and retains all suspended dust particles, thus garanteeing pure
breathable air to the whole family.
PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level
of pollutants, by decomposing the molecules
that form them. Using a series of electric
shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise
the gas pollutant molecules, forming products
that are normally present in clean air. The
result is in the air: you can finally breath
clean, odour-free ionised air.
Silent operation: Thanks to the use of special
centrifugal fans, Omnia fan coils operation is
extremely silent and offers the maximum

acoustic comfort.
3-speed centrifugal fan
Very quiet operation
Slim dimensions
Water connections reversibility during installation
Low pressure drop across heat exchanger
Motors with permanently connected condensers
Easy installation and maintenance
Air filter easy to remove and to clean
Full compliance with safety regulations

Accessories
BC: Auxiliary condensate drip tray.
switch or from the SIT5 card.
BC 10 for vertical installation
SIT5: commands the 3 fan speeds and up to
BC 20 for horizontal installation
two valves (four-pipe systems); it sends the
DSC5: Condensate drainage device for use
thermostat commands to the fancoils netwhen natural run-off is not possible. DSC5 is
work.
not compatible BC10 - BC20 accessories.
SW: Water probe wich enables automatic
SIT 3-5: Thermostat interface cards. They
season change-over thanks to the specific
allow to set up a fancoils network (max. 10)
electronic thermostats.
commanded by a centralised panel (switch or SWA: External probe accessory SWA (length L
thermostat).
= 6m). It detects the temperature of the room
SIT3: commands the three speeds of the fan
air if connected to the connector (A) of the
and must be installed on each fancoil of the
FMT21 panel. The room air temperature
network; it receives the commands from the
probe, incorporated in the panel, is automati-

Omnia UL_P
FMT21
PX2 o PX2C6
PXAE
TPF
WMT05
WMT10
VMF-E4 o E4D
VMF-E0 o E1
AMP10
BC10
BC20
DSC5
SIT3
SIT5
SW3
SWA
VCH
VCHD

38

(1)

(2)

11

16

26

36

cally disabled. It detects the temperature of


the water in the system for ventilation consent
if connected to the connector (W) of the
FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.
VCH: Kit comprising motorized 3-way valve,
unions and copper pipes.
VCHD: Kit comprising motorized 2-way
valve, unions and copper pipes.
ZU: Feet for floor-standing solutions.
Control panels and VMF System: The control
panels are described in a separate document.

(1) PX2C6, PX2 panel in multiple 6-piece pack.


(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.

Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
(1)
W
Heating capacity (70C)
(1)
W
(1)
l/h
(1)
l/h
Water ow rate
(1)
l/h
(1)
kPa
(1)
kPa
Pressure drop
(1)
kPa
(2)
W
(2)
W
Heating capacity (50C)
(2)
W
(2)
l/h
(2)
l/h
Water ow rate
(2)
l/h
(2)
kPa
(2)
kPa
Pressure drop
(2)
kPa
COOLING PERFORMANCE
(3)
W
(3)
W
Total cooling capacity
(3)
W
(3)
W
(3)
W
Sensible cooling capacity
(3)
W
(3)
l/h
(3)
l/h
Water ow rate
(3)
l/h
(3)
kPa
(3)
kPa
Pressure drop
(3)
kPa
m3/h
m3/h
Air ow rate
m3/h
type
Fans
n
W
W
Absorbed power
W
(A)
Max. input current
(4)
dB(A)
(4)
dB(A)
Sound power level
(4)
dB(A)
(5)
dB(A)
(5)
dB(A)
Sound pressure level
(5)
dB(A)
l
Water content

Coil connections

Vel.

UL11P

UL16P

UL26P

UL36P

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

2010
1460
1060
176
128
93
2
1
1
1150
870
650
144
117
93
2
1
1

2910
2120
1540
255
186
135
4
2
1
1700
1250
930
206
153
122
4
2
2

4620
3830
2890
405
336
253
11
8
5
2750
2240
1670
349
289
220
10
7
4

5940
4870
3530
521
427
310
7,7
5,4
3
3540
2860
2080
487
394
286
16
11
6

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

840
680
540
700
530
390
144
117
93
1,9
1
1
180
120
80

1200
890
710
990
710
540
206
153
122
4,8
3
2
240
160
110

2030
1680
1280
1640
1330
990
349
289
220
11
9
5
350
270
190

2830
2290
1660
2040
1620
1160
487
394
286
18,9
12
7
460
350
240

1
18
12
8
0,09
46
37
31
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1

1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1

2
35
27
24
0,18
48
43
35
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1

2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1

Centrifugal
H
M
L
H
M
L
H
M
L

H
M
L

Speed connected
Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; 'T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

Mod Omnia
Height
Widht
Depth
Weight

A
B*
D
C
kg

UL 11P UL 16P UL 26P UL 36P


465
465
465
465
420.5 530.5 761.5 981.5
360.5 470.5 701.5 921.5
171
171
171
171
10.2
11.6
14.9
18.3

Cod.: SOULUY.00/ 1502

A
B

*overall dimensions
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

39

VED

Fan coil unit


For ducted installations
with cooling capacity from 0.99 to 5.82kW

Aermec participates in the EUROVENT


Certification Programme FCP. The
products of interest can be found on the site:
www.eurovent-certification.com

HORIZONTAL OR VERTICAL INSTALLATION


VERSIONS FOR 2/4 PIPE SYSTEMS
1 ROW HEATING ONLY COIL (ACCESSORY BV)
LARGE RANGE OF AVAILABLE STATIC PRESSURE
ACCESSIBLE FAN ASSEMBLY
AIR FILTER CLASS G3
REVERSIBLE COIL

Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:
123

Code

Size

Main Coil

Example:
123
4

VED
0
(VED030 = unit Size 0, with 3 Row Main Coil)

Characteristics

Ducted air conditioning terminal unit


Horizontal and vertical installation
Internal installation
Available in 8 sizes
3 or 4 row coils for 2-pipe systems
3 row main coil and heating only coil accessory for 4-pipe systems
Reversing of hydraulic connections side on
site
Low pressure drop heat exchanger
3-way valve accessory
2-way valve accessory for variable flow systems
6 and 7 speed fan assembly (3 selectable)
Large range of available static pressure

40

Centrifugal fans in anti-static plastic material.


Their characteristics permit energy savings
compared to conventional fans
Fans with aerofoil profile designed to achieve
high airflows and pressures whilst at the same
time producing low noise
Compatible with the VMF system
Large range of controllers
Large range of accessories to satisfy all installation requirements
Compatible with many accessories already
available on the FCX range
Discharge connection supplied loose
Air filter Class G3, for easy removal and
cleaning

Internal insulation in Class 1 fire retardant


material
Protective rating IP20
Fan housing in plastic material removable for
easy and effective cleaning
Ease of installation and maintenance
Full compliance with safety standards.

Accessories
DUCTING ACCESSORIES
Plenum in galvanised sheet steel and connections:
RDA_V: Straight intake connection with rectangular flange.
RDAC_V: Straight intake connection with circular flanges.
RPA_V: Intake plenum with rectangular
flange.
RDMC_V: Straight discharge with circular
flanges. Internally insulated.
PA_V: Intake plenum with circular flanges.
Flanges in plastic material.
RPM_V: Discharge plenum with rectangular
flange. Internally insulated.
PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic
material.
KFV10: Circular flanges kit for intake/discharge plenum.
Discharge and intake grilles:
GA: Intake grille with fixed louvres.
GAF: Intake grille with fixed louvres with filter.
GM: Discharge grille with adjustable louvres.
SE: External air damper with manual control.
INSTALLATION ACCESSORIES
AMP: Hanging kit.
Compatibilit
BC: auxiliaryaccessori
condensate drain tray.
DSC4: Condensate pump to overcome lifts.

ZX: Feet for recessed installation.


HEATING ONLY COIL
BV: 1 row heating only coil.
WATER VALVES
For main coil, 230V~50 Hz / 24V~50 Hz
VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections
and insulated copper tubes.
VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections
and insulated copper tubes.
For heating only coil, 230V~50 Hz / 24V~50 Hz
VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated
copper tubes.
VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated
copper tubes.
VCF3X4: Valve kit for 4 pipe systems and fan
coil units with single coil and 2 connections.
Kit composed of special 3 way motorised valve

CONTROL PANELS
The complete characteristics of the control panels are described in the dedicated files.
Some control panels require combination with
other accessories; consult the relevant documentation.
ACCESSORIES TO COMBINE TO CONTROL
PANELS
SIT 3 - 5: Thermostat Interface Boards. Allows
networking of fan coil units (10 max) controlled by a central panel (switch or thermostat).
SIT3: Controls the 3 speeds of the fan and must
be installed on each fan coil unit on the network; receives controls from the switch or the
SIT5 board.
SIT5: Thermostat interface board. Allows a network of VED units (3 max) controlled by a
single panel PXAE.
SW3: Water temperature sensor for control
panel PXAE.
SWA: Air and water temperature sensor for
with insulating casing, connections and insulated
control panel FMT21.
copper tubes.
VARIABLE MULTI FLOW SYSTEM
Version VCF3X4L for left hand connection fan coils.
VMF System: The complete characteristics of the
Version VCF3X4R for right hand connection fan
VMF system are described in the dedicated
coils.
files.
Power supply 230V ~ 50Hz.
Some VMF components require combination
with other accessories; consult the relevant
documentation.

Accessory Compatibility
Mod.VED
RDA000V
RDA100V
RDA200V
RDA300V
RPA000V ***
RPA100V ***
RPA200V ***
RPA300V ***
RDAC000V
RDAC100V
RDAC200V
RDAC300V
PA000V ***
PA100V ***
PA200V ***
PA300V ***
PM000V ***
PM100V ***
PM200V ***
PM300V ***
RPM000V ***
RPM100V ***
RPM200V ***
RPM300V ***
RDMC000V
RDMC100V
RDMC200V
RDMC300V
BV030
BV130
BV230
BV162
KFV10
VMF-EO
VMF-E1
VMF-SW
VMF-SW1
VMF-E4/E4D
VMF-E5N/E5B
FMT10
FMT21
TPF

030

040

130

140

230

240

340

330

* The valve kits VCF and the drain pan BC4 cannot be installed together on the
same fan coil unit.
** The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.
*** All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs
(=150mm ) on both sides, which can be removed and used with accessories.

Mod.VED
SWA
KTLP
PX
PX2 - PX2C6
PXAR
PXAE
WMT05
WMT06
WMT10
SW3
SIT3
SIT5
VCF43-4324 *
VCF45-4524 *
VCFD3-324 *
VCFD4-424 *
VCF3X4R
VCF3X4L
AMP
BC4 * / **
BC6 **
BC9 **
DSC4 **
GA22
GA32
GA42
GA62
GAF22
GAF32
GAF42
GAF62
GM22
GM32
GM42
GM62
SE20X ****
SE30X ****
SE40X ****
SE80X ****
ZX7
ZX8

030

040

130

140

230

240

340

330

All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) can have intake/discharge
either straight or downwards (straight or downwards with reference to horizontal
installation).
**** Accessories SE must be combined with the feet ZX.

41

Technical data
Mod.
VED
Vel.
030
030*
040
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
BV030
(1)
W
H
3688
3916
Heating capacity (70C)
(1)
W
M
3374
3568
(1)
W
L
1820
2366
343
(1)
l/h
H
323
(1)
l/h
M
296
313
Water ow rate
207
(1)
l/h
L
160
12
(1)
kPa
H
9
(1)
kPa
M
7
Pressure drop
10
4
(1)
kPa
L
3
(2)
W
H
2180
2340
(2)
W
M
1990
2130
Heating capacity (50C)
1410
(2)
W
L
1100
(2)
l/h
H
279
327
296
Water ow rate
(2)
l/h
M
250
193
(2)
l/h
L
170
(2)
kPa
H
8
12
(2)
kPa
M
7
10
Pressure drop
(2)
kPa
L
3
5
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
2220
(3)
W
H
(3)
W
M
Heating capacity (70C)
2080
1590
(3)
W
L
196
(3)
l/h
H
(3)
l/h
M
Water ow rate
183
140
(3)
l/h
L
8
(3)
kPa
H
(3)
kPa
M
Pressure drop
7
5
(3)
kPa
L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1624
1592
1900
Total cooling capacity
1416
1720
(4)
W
M
1454
(4)
W
L
990
984
1120
(4)
W
H
1242
1218
1350
Sensible cooling capacity
1094
1230
(4)
W
M
1116
(4)
W
L
750
745
810
274
327
(4)
l/h
H
279
244
296
(4)
l/h
M
250
Water ow rate
(4)
l/h
L
170
169
193
9
9
14
(4)
kPa
H
Pressure drop
(4)
kPa
M
7
7
12
(4)
kPa
L
3
3
5
m3/h
H
285
280
277
m3/h
Air ow rate
M
256
250
249
L
161
160
160
m3/h
type
Fans
n
1
1
1
Pa
H
61
61
61
High static pressure
50
50
Pa
M
50
Pa
L
21
21
21
W
H
59
59
58
Absorbed power
W
M
38
38
38
W
L
23
23
23
Max. input current
(A)
0,37
0,37
0,37
(5)
dB(A)
H
54
54
54
Sound power level (inlet+radiator)
(5)
dB(A)
M
52
52
52
(5)
dB(A)
L
44
44
44
(5)
dB(A)
H
50
50
50
Sound power level (outlet)
M
48
48
48
(5)
dB(A)
(5)
dB(A)
L
40
40
40
Water content
l
l
Water content (additional heat exchanger)
Coil connections
Gas (F)
3/4"
3/4"
3/4"
Coil connections (additional heat exchanger)
Gas (F)
1/2"
H
V6
V6
V6
M
V4
V4
V4
Speed connected
L
V1
V1
V1

Power supply

130

140

230

6289
5833
4397
551
511
385
26
22
13
3750
3480
2620
516
480
358
27
23
13

130*
BV130
-

240

330

7160
6500
5350
616
559
460
37
30
27
4320
3920
3230
588
538
445
35
29
20

230*
BV230
-

6575
6089
4518
576
534
396
18
16
9
3940
3650
2710
566
525
390
19
16
9

3780
3596
2946
331
315
258
28
25
17

2997
2790
2080
2090
1940
1440
515
480
358
31
27
15
433
397
287

2931
2727
2029
2169
1900
1400
504
469
349
31
27
15
423
388
280

2
60
50
26
76
53
34
0,41
55
53
47
50
48
42

2
60
50
26
76
53
34
0,41
55
53
47
50
48
42

3/4"
V6
V4
V1

3/4"
1/2"
V6
V4
V1

10507
9343
7813
921
819
685
16
13
9
6270
5580
4670
860
760
633
16
13
9

330*
BV162
-

7909
7141
5800
684
616
499
3
26
18
4750
4290
3450
691
624
499
31
26
13

4493
4171
3675
394
366
322
16
14
11

3290
3420
3050
3130
2270
2590
2370
2700
2190
2440
1610
2000
566
588
525
538
390
445
23
44
20
36
11
25
420
590
386
524
280
417
centrifugal
2
2
60
64
50
50
26
32
75
93
52
57
34
43
0,41
0,58
55
57
53
54
47
49
50
42
48
49
42
44

3/4"
3/4"
V6
V6
V4
V3
V1
V1
230V/1/50Hz

10951
10017
8312
960
878
729
32
28
22
6550
5980
4970
922
824
685
21
17
13

5888
5499
4896
515
482
429
26
23
19

3380
3080
2500
2600
2350
1900
581
530
430
42
35
23
582
513
412

4020
3630
2900
3015
2718
2200
691
624
499
37
31
16
570
509
406

5000
4420
3680
3738
3337,5
2800
860
760
633
18
14
10
805
704
572

4946
4380
3600
3670
3280
2720
851
753
619
18
14
9
790
695
568

5360
4790
3980
3990
3570
2950
922
824
685
26
21
16
775
685
563

2
64
50
32
93
57
43
0,58
57
54
49
42
49
44

2
63
50
32
92
57
43
0,58
57
54
49
42
49
44

3
66
50
33
104
75
63
0,66
58
55
38
54
51
34

3
66
50
33
104
75
63
0,66
58
55
38
54
51
34

3
64
50
34
103
74
63
0,66
58
55
38
54
51
34

3/4"
1/2"
V7
V3
V1

3/4"
V6
V3
V1

3/4"
V7
V3
V1

3/4"
1/2"
V7
V3
V1

3/4"
V7
V3
V1

H max. speed; M med. speed; L min. speed


VED30240
Heating mode
2 pipes system configuration
V1 V2 V3 V4
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
L6 L5 L4 L3
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
V1 V2 V3 V4
* 4 pipes system configuration (with additional heat exchanger) (BV)
L7 L6 L5 L4
(3)Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
VED330340
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection
available on the website www.aermec.com

42

340

V5
L2

V6 Speed
L1 motor connected

V5
L3

V6
L2

V7
L1

and the technical documentation

Dimensions (mm)

VED: 030 - 040 - 130 - 140 - 230 - 240 - 330 - 340

A
B
25

25

217
167

24

24

111

25

141

253

Asola 20x9

41

96
156

0,5

350

584

149

378

98

273

17,5

VED

030

040

130

140

230

240

330

340

1148

1148

mm

576

576

807

807

1027

1027

mm

550

550

781

781

1001

1001

1122

1122

mm

500

500

731

731

951

951

1072

1072

mm

530

530

761

761

981

981

1102

1102

Net weight

kg

20

21

23

24

29,5

32

32,5

34

Cod.: SVED0UY.03 / 1501

B
C

The technical data shown in this documentation is not binding.


Aermec S.p.A. reserves the right to make all modification deemed
necessary for improving the product at any time.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

43

VED

Air handling terminal with cooling capacities from 8 to 18 kW


For ducted systems

AERMEC partecipates in the


EUROVENT programme for: FCP
Check ongoing validity of certificate
online: www.eurovent-certification.com

HORIZONTAL AND VERTICAL INSTALLATION


VERSIONS FOR 2/4 PIPE SYSTEMS
HEAT EXCHANGER ONLY WITH 1 OR 2 ROWS
WIDE RANGE OF USEFUL STATIC PRESSURE
5 SPEED VENTILATION UNIT
INSPECTIONABLE FAN UNIT
CLASS G3 AIR FILTER
COIL REVERSIBILITY

Choosing the unit


By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.

Fields configurator:
123

Size

Main coil
n. rows

Heating only coil


n. rows

Code
123

VED

(VED532 = unit size 5, with Main Coil 3 Rows and Heating Coil 2 Rows)

Features

Air handling terminal for ducted systems


EUROVENT FCP Certification Program
Horizontal and vertical installation
Indoor installation
Available in 4 sizes and 4 configurations
Versions for 2 pipe systems with 3 or 4 row
coil
Versions for systems with 4 pipes with main
coil with 3 or 4 rows and heating only coil
with 1 or 2 rows
Reversibility of the hydraulic connection in
the installation phase
Low pressure drop in the heat exchange coils
3-way valves accessories
2-way valves accessories for systems with var-

44

iable water flow rate


5 speed fan unit (3 selectable)
Wide range of useful static pressure
Centrifugal fans in antistatic plastic. Due to
their features, they allow to reduce the energy
consumption with respect to normal fans
Fans with wing-shaped profile studied to
obtain high flow rate and static pressure performance and low noise emission at the same
time
Compatible with the VMF system
Wide range of controls
Wide range of accessories to satisfy all system
requirements
Rectangular flow flange already integrated

into the framework


Class G3 air filter with easy extraction and
cleaning
Internal insulation in Class 1 fire resistance
IP20 protection rating
Plastic augers, extractable for easy and
efficient cleaning
Easy installation and maintenance
Full respect of the accident-prevention
standards

Accessories
VCF4_H: Kit made up from motorised 3-way
valves, fittings and isolated copper pipes. For
heating only coils. 230V~50 Hz power
supply
VCF2_C: Kit made up from motorised 2-way
valves, with fittings and isolated copper
pipes. For main coils. 230V~50 Hz power
supply
VCF2_H: Kit made up from motorised 2-way
valves, with fittings and copper pipes.
For heating only coils. 230V~50 Hz power
supply

RDA_V: Straight fitting with rectangular


flange for ducting.
In galvanised sheet steel
RPA_V: Intake plenum with rectangular
flange for ducting.
In galvanised sheet steel
PA_V: Intake plenum with circular flanges for
ducting.
In galvanised sheet steel, the flanges are in
plastic
RPM_V: Flow plenum with rectangular flange
for ducting.
In galvanised sheet steel, internally isolated.
PM_V: Flow plenum with circular flanges for
ducting
In galvanised sheet steel, internally isolated,
the flanges are in plastic
KFV: Circular flange kit for intake/flow
plenum.
In plastic
VCF4_C: Kit made up from motorised 3-way
valves with isolating shell, fittings and
isolated copper pipes. For main coils.
230V~50 Hz power supply

coupled to thermostats different to the VMF


System
SIT5: Thermostat interface board.
Allows to realise a network of VED units
(max 3) controlled by a centralised PXAE
panel
SW3: Water minimum temperature probe to
use with PXAE control panel.

VARIABLE MULTI FLOW SYSTEM


VMF System: The complete fittings of the VMF
System management system are described in
the dedicated sheet.
Some VMF components require coupling with
CONTROL PANELS
other accessories, consult the relative
The complete features of the control panels are
documentation.
described in the dedicated sheet.
Some control panels require coupling with VMF-SIT 3 : Thermostat Interface Board
VMF. Mandatory accessory on the VED unit
other accessories, consult the relative
supplied with VMF-E0 / E1 thermostat.
documentation.

ACCESSORIES TO COUPLE WITH THE


CONTROL PANELS
SIT3 : Thermostat interface board
Mandatory accessory on the VED units

Accessories compatibility
Mod. VED
RDA 450 V
RDA 670 V
RPA 450 V
RPA 670 V
PA 450 V
PA 670 V
RPM 450 V
RPM 670 V
PM 450 V
PM 670 V
KFV

430

432

440

441

530

532

540

541

SW3
SIT 3*
SIT 5**
PXAE
WMT05
WMT06
WMT10

VCF45C
VCF45H
VCF47C
VCF47H
VCF25C
VCF25H

VMF-SIT3***
VMF-E0
VMF-E1
VMF-SW
VMF-SW1
VMF-E4/E4D
VMF-E5B
VMF-E5N

* SIT3
** SIT5
*** VMF-SIT3

630

632

640

641

730

732

740

741

=Mandatory accessory on the VED units coupled to thermostats different to the VMF System
= Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel
= Mandatory accessory for coupling with VMF-E0 or VMF-E1

45

Technical data
Mod.
VED
Vel. 430 432 440 441
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
18110
(1)
W
H 15974
Heating capacity (70C)
(1)
W
M 13845
15358
(1)
W
L 10469
11445
1588
(1)
l/h
H 1401
Water ow rate
(1)
l/h
M 1214
1347
(1)
l/h
L
918
1004
(1)
kPa
H
19
24
Pressure drop
(1)
kPa
M
14
18
(1)
kPa
L
9
11
10700
(2)
W
H 9470
(2)
W
M 8250
9130
Heating capacity (50C)
(2)
W
L
6200
6810
(2)
l/h
H 1195
1378
Water ow rate
(2)
l/h
M 1058
1214
(2)
l/h
L
805
918
(2)
kPa
H
17
19
(2)
kPa
M
11
15
Pressure drop
(2)
kPa
L
7
9
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
12090
8160
Heating capacity (70C)
(3)
W
M
10725
7480
(3)
W
L
8280
6190
(3)
l/h
H
1060
716
Water ow rate
(3)
l/h
M
940,7
656
(3)
l/h
L
726,2
543
(3)
kPa
H
18
28
Pressure drop
(3)
kPa
M
14
24
(3)
kPa
L
9
17
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H 6950 6950 8010 8010
Total cooling capacity
(4)
W
M 6150 6150 7060 7060
(4)
W
L
4680 4680 5340 5340
(4)
W
H 5360 5360 5730 5730
Sensible cooling capacity
(4)
W
M 4710 4710 5040 5040
(4)
W
L
3540 3540 3780 3780
(4)
l/h
H 1195 1195 1378 1378
Water ow rate
(4)
l/h
M 1058 1058 1214 1214
(4)
l/h
L
805 805 918 918
(4)
kPa
H
17
17
22
22
Pressure drop
(4)
kPa
M
13
13
17
17
(4)
kPa
L
8
8
10
10
m3/h
H 1350 1250 1340 1250
m3/h
M 1130 1060 1100 1060
Air ow rate
m3/h
L
790 750 780 750
type
Fans
n
2
2
2
2
Pa
H
72
70
70
70
High static pressure
Pa
M
50
50
50
50
Pa
L
24
25
24
25
W
H
228 215 222 215
Absorbed power
W
M
175 175 178 175
W
L
137 130 135 130
Max. input current
(A)
(5)
dB(A)
H
53
61
Sound power level (inle+radiator)
(5)
dB(A)
M
57
57
(5)
dB(A)
L
42
51
(5)
dB(A)
H
49
57
Sound power level (outlet)
(5)
dB(A)
M
53
53
(5)
dB(A)
L
38
47
Water content
l
l
Water content (additiona heat exchanger)
Coil connections
Gas (F)
3/4 3/4 3/4 3/4
Coil connections (additiona heat exchanger)
Gas (F)
1/2
1/2
H
V5
V5
V5
V5
M
V3
V3
V3
V3
Speed connected
L
V1
V1
V1
V1

Power supply

530

532

540

541

630

632

640

641

730

732

740

741

17572
16467
13802
1541
1444
1211
21
18
13
10420
9780
8190
1335
1271
1060
16
15
11

19908
18586
15377
1746
1630
1349
29
25
18
11820
11050
9170
1543
1469
1278
23
21
16

27016
22672
18628
2370
1989
1634
58
43
30
16070
13500
11100
2155
1840
1529
48
36
26

32688
27744
22454
2867
2434
1970
38
29
19
17930
14940
11980
2611
2195
1794
36
27
19

28999
25364
21178
2544
2225
1858
67
55
38
17280
15120
12640
2382
2098
1789
57
44
33

31706
27650
22883
2781
2425
2007
46
36
26
19150
16680
13840
2766
2448
2057
35
28
21

13540
12850
10720
1188
1127
940
22
20
14

8850
8520
7475
776
747
656
32
30
24

20513
17726
14665
1799
1555
1286
28
22
16

13750
12370
10770
1206
1085
945
28
23
18

22174
19726
16728
1945
1730
1467
33
26
20

14500
13300
11830
1272
1167
1038
30
26
21

7760
7390
6160
6020
5710
4720
1335
1271
1060
21
19
12
1520
1400
1120

7760
7390
6160
6020
5710
4720
1335
1271
1060
21
19
12
1460
1360
1060

8970
8540
7430
6450
6130
5040
1543
1469
1278
28
25
19
1500
1380
1100

2
58
50
32
270
232
175

2
56
50
32
266
229
170

2
56
50
32
267
230
172

62
59
53
58
55
49

8970 12530 12530 15180 15180 13850 13850 16080 16080


8540 10700 10700 12760 12760 12200 12200 14230 14230
7430 8890 8890 10430 10430 10400 10400 11960 11960
6450 10300 10300 10660 10660 11440 11440 11320 11320
6130 8750 8750 8910 8910 9990 9990 9970 9970
5040 7220 7220 7240 7240 8480 8480 8340 8340
1543 2155 2155 2611 2611 2382 2382 2766 2766
1469 1840 1840 2195 2195 2098 2098 2448 2448
1278 1529 1529 1794 1794 1789 1789 2057 2057
28
48
48
41
41
58
58
45
45
25
36
36
30
30
46
46
37
37
19
26
26
21
21
35
35
27
27
1460 2210 2110 2440 2110 2410 2350 2350 2350
1360 1800 1730 2004 1730 2040 2000 2000 2000
1060 1380 1340 1567 1340 1640 1600 1600 1600
centrifugal
2
3
3
3
3
3
3
3
3
56
75
75
75
75
69
69
69
69
50
50
50
50
50
50
50
50
50
32
30
30
30
30
32
32
32
32
266 339 340 340 340 371 372 371 372
229 268 264 260 264 285 288 285 288
170 224 223 220 223 234 227 234 227

62
59
53
58
55
49

3/4
-

3/4
1/2

3/4
-

V5
V4
V2

V5
V4
V2

V5
V4
V2

68
64
59
64
60
55

3/4
1/2

3/4
-

V5
V5
V4
V3
V2
V1
230V/1/50Hz

68
64
59
64
60
55

68
66
62
64
62
58

68
66
62
64
62
58

3/4
1/2

3/4
-

3/4
1/2

3/4
-

3/4
1/2

3/4
-

3/4
1/2

V5
V3
V1

V5
V3
V1

V5
V3
V1

V5
V3
V1

V5
V3
V1

V5
V3
V1

V5
V3
V1

H max. speed; M med. speed; L min. speed


VED430741
Heating mode
Speed
V1 V2 V3 V4 V5
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
L5 L4 L3 L2 L1 motor connected
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation
available on the website www.aermec.com

46

Dimensional data (mm)

VED: 430 - 432 - 440 - 441 - 530 - 532 - 540 - 541

20

10
1158
1133

300
256

15

130

25

1053

440

737

248
287

45
109
241
198
16

141

403
362
313

275

1104
1109

VED
Weight

Kg

430

432

440

441

530

532

540

541

41

46

43

46

42

47

47

47

VED: 630 - 632 - 640 - 641 - 730 - 732 - 740 - 741

20

1558
1533
1453

40

40

351
307

15

150

25

10

789
440

280
316

46
109

16

174

329

423
379

247
287
326

VED
Weight

Kg

630

632

640

641

730

732

740

741

57

57

60

60

58

64

61

64

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

Code : SVEDUY.02 / 1502

1504
1509

47

VED_I

Fan coil unit with Brushless Inverter motor (EC)


for ducted systems
Cooling capacities 0,995,82kW

AERMEC
partecipates in the EUROVENT
programme for: FCP
Check ongoing validity of certificate
online: www.eurovent-certification.com

HORIZONTAL OR VERTICAL INSTALLATION


VERSIONS FOR 2/4 PIPE SYSTEMS
1 ROW HEATING ONLY COIL (ACCESSORY BV)
LARGE RANGE OF AVAILABLE STATIC PRESSURE
CENTRIFUGAL FANS INVERTER
ACCESSIBLE FAN ASSEMBLY
AIR FILTER CLASS G3
REVERSIBLE COIL

Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:
123

Code

Size

Main Coil

Main coil
only hot

Inverter
motor

Example:
123

VED

Characteristics

Ducted air conditioning terminal unit


Internal installation
3 or 4 row coils for 2-pipe systems
3 row main coil and heating only coil accessory for 4-pipe systems
Reversing of hydraulic connections side on
site
Low pressure drop heat exchanger
3-way valve accessory
2-way valve accessory for variable flow systems
Centrifugal fans with motor inverter
Large range of available static pressure
Centrifugal fans in anti-static plastic material.

48

Their characteristics permit energy savings


compared to conventional fans
Fans with aerofoil profile designed to achieve
high airflows and pressures whilst at the same
time producing low noise
Compatible with the VMF system
Large range of controllers
Large range of accessories to satisfy all installation requirements
Discharge connection supplied loose
Air filter Class G3, for easy removal and
cleaning
Internal insulation in Class 1 fire retardant
material

Protective rating IP20


Fan housing in plastic material removable for
easy and effective cleaning
Ease of installation and maintenance
Full compliance with safety standards.

Accessories
DUCTING ACCESSORIES
Plenum in galvanised sheet steel and connections:
RDA_V: Straight intake connection with rectangular flange.
RDAC_V: Straight intake connection with circular flanges.
RPA_V: Intake plenum with rectangular
flange.
RDMC_V: Straight discharge with circular
flanges. Internally insulated.
PA_V: Intake plenum with circular flanges.
Flanges in plastic material.
RPM_V: Discharge plenum with rectangular
flange. Internally insulated.
PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic
material.
PMZ: Plenum with motorized dampers (for
more details refer to the dedicated card).
KFV10: Circular flanges kit for intake/discharge plenum.
Discharge and intake grilles:
GA: Intake grille with fixed louvres.
Compatibilit
GAF: Intake accessori
grille with fixed louvres with filter.
GM: Discharge grille with adjustable louvres.

Mod.VED
RDA000V
RDA100V
RDA200V
RDA300V
RPA000V
RPA100V
RPA200V
RPA300V
RDAC000V
RDAC100V
RDAC200V
RDAC300V
PA000V
PA100V
PA200V
PA300V
PM000V
PM100V
PM200V
PM300V
PMZ
RPM000V
RPM100V
RPM200V
RPM300V
RDMC000V
RDMC100V
RDMC200V
RDMC300V
BV030
BV130
BV230
BV162
KFV10
WMT21
SWAI
VMF-E18
VMF-SW
VMF-SW1
VMF-E4
VMF-E4D
VMF-E5N
VMF-E5B

030I

040I

130I

140I

SE: External air damper with manual control.

ZX: Feet for recessed installation.


HEATING ONLY COIL
BV: 1 row heating only coil.
WATER VALVES
For main coil, 230V~50 Hz / 24V~50 Hz
VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections
and insulated copper tubes.
VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections
and insulated copper tubes.
For heating only coil, 230V~50 Hz / 24V~50 Hz
VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated
copper tubes.
VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated
copper tubes.
VCF3X4: Valve kit for 4 pipe systems and fan
coil units with single coil and 2 connections.
Kit composed of special 3 way motorised valve

230I

240I

330I

(1)
(1)
(1)
(1)

(1)
(1)
(1)
(1)

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

340I

with insulating casing, connections and insulated


copper tubes.
Version VCF3X4L for left hand connection fan coils.
Version VCF3X4R for right hand connection fan
coils.
Power supply 230V ~ 50Hz.

INSTALLATION ACCESSORIES
AMP: Hanging kit.
BC: auxiliary condensate drain tray.
DSC4: Condensate pump to overcome lifts.

Mod.VED
VCF43-4324
VCF45-4524
VCFD3-324
VCFD4-424
VCF3X4R
VCF3X4L
AMP
BC4
BC6
BC9
DSC4
GA22
GA32
GA42
GA62
GAF22
GAF32
GAF42
GAF62
GM22
GM32
GM42
GM62
SE20X
SE30X
SE40X
SE80X
ZX7
ZX8

030I

(2)(3)
(3)

(3)

(3)

(2)
(2)
(2)
(2)

CONTROL PANELS
The complete characteristics of the control panels are described in the dedicated files.
Some control panels require combination with
other accessories; consult the relevant documentation.
WMT21: Electronic thermostat wall-mount
installation
SWAI: Air and water temperature sensor for
WMT21.
Variable Multi Flow System (VMF)
The complete characteristics of the VMF system
are described in the dedicated files.
Some VMF components require combination
with other accessories; consult the relevant documentation.

040I

130I

140I

230I

240I

(4)
(4)
(4)
(4)

340I

330I

(1) All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (=150mm ) on both sides, which can be removed; All the Plenums can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation).
(2) The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit.
(3) The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.
49
(4) Accessories SE must be combined with the feet ZX

Technical data
Mod.

VED

Vel.

30I

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

030I*
BV030

40I

3916
3568
2366
343
Water ow rate
313
207
12
Pressure drop
10
4
2340
Heating capacity (50C)
2130
1410
327
Water ow rate
296
193
12
Pressure drop
10
5
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70C)

Heating capacity (70C)

Water ow rate

Pressure drop

130I

130*
BV130

140I

230I

230*
BV230

240I

330I

330*
BV162

340I

6289
5833
4397
551
511
385
26
22
13
3750
3480
2620
516
480
358
27
23
13

6575
6089
4518
576
534
396
18
16
9
3940
3650
2710
566
525
390
19
16
9

7160
6500
5350
616
559
460
37
30
27
4320
3920
3230
588
538
445
35
29
20

7909
7141
5800
684
616
499
3
26
18
4750
4290
3450
691
624
499
31
26
13

10507
9343
7813
921
819
685
16
13
9
6270
5580
4670
860
760
633
16
13
9

10951
10017
8312
960
878
729
32
28
22
6550
5980
4970
922
824
685
21
17
13

4493
4171
3675
394
366
322
16
14
11

5888
5499
4896
515
482
429
26
23
19

3380
3080
2500
2600
2350
1900
581
530
430
42
35
23
582
513
412

4020
3630
2900
3015
2718
2200
691
624
499
37
31
16
570
509
406

5000
4420
3680
3738
3337,5
2800
860
760
633
18
14
10
805
704
572

4946
4380
3600
3670
3280
2720
851
753
619
18
14
9
790
695
568

5360
4790
3980
3990
3570
2950
922
824
685
26
21
16
775
685
563

2
64
50
32
53
40
24
0,5
57
54
49
42
49
44

2
63
50
32
53
40
24
0,5
57
54
44
52
49
39
1,48
3/4"
9V
7,8V
6,2V

3
66
50
33
86
60
35
0,5
58
55
38
54
51
34
2,52
3/4"
9V
7,8V
6,2V

3
66
50
33
86
60
35
0,5
58
55
38
54
51
34

3
64
50
34
86
60
35
0,5
58
55
38
54
51
34
3,4
3/4"
9V
7,8V
6,6V

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

W
W
W
l/h
l/h
l/h
kPa
kPa
kPa
W
W
W
l/h
l/h
l/h
kPa
kPa
kPa

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

3688
3374
1820
323
296
160
9
7
3
2180
1990
1100
279
250
170
8
7
3

(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)

W
W
W
l/h
l/h
l/h
kPa
kPa
kPa

H
M
L
H
M
L
H
M
L

2220
2080
1590
196
183
140
8
7
5

3780
3596
2946
331
315
258
28
25
17

1624
1454
990
1242
1116
750
279
250
170
9
7
3
285
256
161

1592
1416
984
1218
1094
745
274
244
169
9
7
3
280
250
160

1900
1720
1120
1350
1230
810
327
296
193
14
12
5
277
249
160

2997
2790
2080
2090
1940
1440
515
480
358
31
27
15
433
397
287

2931
2727
2029
2169
1900
1400
504
469
349
31
27
15
423
388
280

1
61
50
21
36
29
12
0,33
54
52
39
50
48
34
1,11
3/4"
9V
8,2V
5,4V

1
61
50
21
36
29
12
0,33
54
52
44
50
48
40

1
61
50
21
36
29
12
0,33
54
52
39
50
48
34
1,48
3/4"
9V
8,2V
5,4V

2
60
50
26
45
33
17
0,41
55
53
45
50
48
39
1,5
3/4"
9V
8,2V
5,8V

2
60
50
26
45
33
17
0,41
55
53
47
50
48
42

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)


Total cooling capacity

Sensible cooling capacity

Water ow rate

Pressure drop

(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)

Air ow rate
Fans
High static pressure

Absorbed power
Max. input current
Sound power level (inlet+radiator)

Sound power level (outlet)


Water content
Coil connections
Coil connections (additiona heat exchanger)
Signal 0-10V

Power supply

(5)
(5)
(5)
(5)
(5)
(5)

W
H
W
M
W
L
W
H
W
M
W
L
l/h
H
l/h
M
l/h
L
kPa
H
kPa
M
kPa
L
m3/h
H
m3/h
M
m3/h
L
type
n
Pa
H
Pa
M
Pa
L
W
H
W
M
W
L
(A)
dB(A)
H
dB(A)
M
dB(A)
L
dB(A)
H
dB(A)
M
dB(A)
L
l
Gas (F)
Gas (F)
H
M
L

3/4"
1/2"
9V
8,2V
5,4V

3/4"
1/2"
9V
8,2V
5,8V

3290
3420
3050
3130
2270
2590
2370
2700
2190
2440
1610
2000
566
588
525
538
390
445
23
44
20
36
11
25
420
590
386
524
280
417
centrifugal
2
2
60
64
50
50
26
32
45
53
33
40
17
24
0,41
0,5
55
57
53
54
45
44
50
52
48
49
39
39
1,48
1,48
3/4"
3/4"
9V
9V
8,2V 8,2V
5,8V 6,6V
230V/1/50Hz

3/4"
1/2"
9V
8,2V
6,6V

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
* 4 pipes system configuration with additional heat exchanger (BV)
(3)Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com

50

3/4"
1/2"
9V
7,8V
6,2V

Dimensional data (mm)


VED: 030I - 040I - 130I - 140I - 230I - 240I - 330I - 340I

A
B
25

25

217
167

24

24

111

25

141

253

Asola 20x9

41

96
156

0,5

350

584

149

378

98

273

17,5

VED

030I

040I

130I

140I

230I

240I

330I

340I

1148

1148

mm

576

576

807

807

1027

1027

mm

550

550

781

781

1001

1001

1122

1122

mm

500

500

731

731

951

951

1072

1072

mm

530

530

761

761

981

981

1102

1102

Net weight

Kg

20

21

23

24

29,5

32

32,5

34

Cod.: SVEDI030_340UY.02 / 1410

B
C

The technical data in this document is not binding. Aermec S.p.A.


reserves the right to make any changes at any time deemed
necessary for product improvement.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293730
www.aermec.com

51

VED_I

Fan coil unit with Brushless Inverter motor (EC)


for ducted systems
Cooling capacities 810kW

AERMEC
partecipates in the EUROVENT
programme for: FCP
Check ongoing validity of certificate
online: www.eurovent-certification.com

HORIZONTAL OR VERTICAL INSTALLATION


VERSIONS FOR 2/4 PIPE SYSTEMS
1 -2 ROW HEATING ONLY COIL
LARGE RANGE OF AVAILABLE STATIC PRESSURE
CENTRIFUGAL FANS INVERTER
ACCESSIBLE FAN ASSEMBLY
AIR FILTER CLASS G3
REVERSIBLE COIL

Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:
123

Main Coil

Main coil
only hot

Inverter
motor

Code

Size

Example:
123

VED

Characteristics
Ducted air conditioning terminal unit
Internal installation
3 row main coil and heating only coil accessory for 4-pipe systems
Versions for systems with 4 pipes with main
coil with 3 or 4 rows and heating only coil
with 1 or 2 rows
Reversibility of the hydraulic connection in
the installation phase
Low pressure drop in the heat exchange coils
3-way valves accessories
2-way valves accessories for systems with variable water flow rate
Centrifugal fans with motor inverter
Wide range of useful static pressure

52

Centrifugal fans in antistatic plastic. Due to


their features, they allow to reduce the energy
consumption with respect to normal fans
Fans with wing-shaped profile studied to
obtain high flow rate and static pressure performance and low noise emission at the same
time
Compatible with the VMF system
Wide range of controls
Wide range of accessories to satisfy all system
requirements
Rectangular flow flange already integrated
into the framework
Class G3 air filter with easy extraction and
cleaning

Internal insulation in Class 1 fire resistance


IP20 protection rating
Plastic augers, extractable for easy and
efficient cleaning
Easy installation and maintenance
Full respect of the accident-prevention
standards

Accessori
Accessories
lated, the flanges are in plastic
KFV: Circular flange kit for intake/flow
plenum.
In plastic
VCF4_C: Kit made up from motorised
3-way valves with isolating shell, fittings
and
isolated copper pipes. For main coils.
230V~50 Hz power supply
VCF4_H: Kit made up from motorised
3-way valves, fittings and isolated copper pipes. For heating only coils.
230V~50 Hz power
supply
VCF25C: Kit made up from motorised
2-way valves, with fittings and isolated
copper pipes. For main coils. 230V~50
Hz power supply
VCF25H: Kit made up from motorised
2-way valves, with fittings and copper

RDA_V: Straight fitting with rectangular


flange for ducting.
In galvanised sheet steel
RPA_V: Intake plenum with rectangular
flange for ducting.
In galvanised sheet steel
PA_V: Intake plenum with circular flanges for ducting.
In galvanised sheet steel, the flanges are
in plastic
RPM_V: Flow plenum with rectangular
flange for ducting.
In galvanised sheet steel, internally isolated.
PM_V: Flow plenum with circular flanges for ducting
PMZ: plenum con amortiguadores
motorizados (para ms detalles consulte
la tarjeta dedicada).
In galvanised sheet steel, internally iso-

Accessoires
Mod. VED
RDA 450 V
RDA 670 V
RPA 450 V
RPA 670 V
PA 450 V
PA 670 V
RPM 450 V
RPM 670 V
PM 450 V
PM 670 V
PMZ
KFV

530I

532I

540I

541I

pipes.
For heating only coils. 230V~50 Hz
power supply
WMT21: Electronic thermostat wallmount installation
SWAI: Water minimum temperature
probe to use with WMT21 control panel.
VARIABLE MULTI FLOW SYSTEM
VMF System: The complete fittings of the
VMF System management system are
described in the dedicated sheet.
Some VMF components require coupling
with other accessories, consult the relative
documentation.

730I

732I

740I

741I

VCF45C
VCF45H
VCF47C
VCF47H
VCF25C
VCF25H

VMF-E18
VMF-SW
VMF-SW1
VMF-E4
VMF-E4D
VMF-E5B
VMF-E5N

53

Technical data
Mod.
VED
Vel.
530I
532I
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
H
17572
Heating capacity (70C)
(1)
W
M
16467
(1)
W
L
13802
1541
(1)
l/h
H
Water ow rate
(1)
l/h
M
1444
(1)
l/h
L
1211
21
(1)
kPa
H
Pressure drop
(1)
kPa
M
18
(1)
kPa
L
13
(2)
W
H
10420
(2)
W
M
9780
Heating capacity (50C)
(2)
W
L
8190
1335
(2)
l/h
H
Water ow rate
(2)
l/h
M
1271
(2)
l/h
L
1060
(2)
kPa
H
16
(2)
kPa
M
15
Pressure drop
(2)
kPa
L
11
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
13540
(3)
W
H
Heating capacity (70C)
(3)
W
M
12850
(3)
W
L
10720
1188
(3)
l/h
H
Water ow rate
(3)
l/h
M
1127
(3)
l/h
L
940
(3)
kPa
H
22
Pressure drop
(3)
kPa
M
20
(3)
kPa
L
14
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
7760
7760
Total cooling capacity
(4)
W
M
7390
7390
(4)
W
L
6160
6160
(4)
W
H
6020
6020
Sensible cooling capacity
(4)
W
M
5710
5710
(4)
W
L
4720
4720
1335
1335
(4)
l/h
H
Water ow rate
(4)
l/h
M
1271
1271
(4)
l/h
L
1060
1060
21
21
(4)
kPa
H
Pressure drop
(4)
kPa
M
19
19
(4)
kPa
L
12
12
m3/h
H
1520
1460
Air ow rate
m3/h
M
1400
1360
m3/h
L
1120
1060
type
Fans
n
2
2
58
56
Pa
H
High static pressure
Pa
M
50
50
Pa
L
32
32
205
185
W
H
Absorbed power
W
M
170
163
W
L
115
106
(5)
dB(A)
H
62
Sound power level (inlet+radiator)
(5)
dB(A)
M
59
(5)
dB(A)
L
53
(5)
dB(A)
H
58
Sound power level (outlet)
(5)
dB(A)
M
55
(5)
dB(A)
L
49
Coil connections
Gas (F)
3/4
3/4
Coil connections (additiona heat exchanger)
Gas (F)
1/2
H
9V
9V
Signal 0-10V
M
8,4V
8,4V
L
6,6V
6,6V

Power supply

540I

541I

730I

732I

740I

741I

19908
18586
15377
1746
1630
1349
29
25
18
11820
11050
9170
1543
1469
1278
23
21
16

28999
25364
21178
2544
2225
1858
67
55
38
17280
15120
12640
2382
2098
1789
57
44
33

31706
27650
22883
2781
2425
2007
46
36
26
19150
16680
13840
2766
2448
2057
35
28
21

8850
8520
7475
776
747
656
32
30
24

22174
19726
16728
1945
1730
1467
33
26
20

14500
13300
11830
1272
1167
1038
30
26
21

13850
12200
10400
11440
9990
8480
2382
2098
1789
58
46
35
2350
2000
1600

16080
14230
11960
11320
9970
8340
2766
2448
2057
45
37
27
2350
2000
1600

16080
14230
11960
11320
9970
8340
2766
2448
2057
45
37
27
2350
2000
1600

3
69
50
32
363
240
138

3
69
50
32
370
245
140
68
66
62
64
62
58

3
69
50
32
363
240
138

8970
8540
7430
6450
6130
5040
1543
1469
1278
28
25
19
1500
1380
1100
2
56
50
32
205
170
115
62
59
53
58
55
49

8970
13850
8540
12200
7430
10400
6450
11440
6130
9990
5040
8480
1543
2382
1469
2098
1278
1789
28
58
25
46
19
35
1460
2410
1360
2040
1060
1640
centrifugal
2
3
56
69
50
50
32
32
185
370
163
245
106
140
64
66
62
64
62
58

3/4
-

3/4
1/2

3/4
-

3/4
1/2

3/4
-

3/4
1/2

9V
8,4V
6,6V

9V
9V
8,4V
7,6V
6,6V
6,2V
230V/1/50Hz

9V
7,6V
6,2V

9V
7,6V
6,2V

9V
7,6V
6,2V

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com

54

Dimensional data (mm)


VED: 530I - 532I - 540I - 541I

20

10
1158
1133

300
256

15

130

25

1053

440

737

248
287

45
109
241
198
16

141

403
362
313

275

1104
1109

VED
Weight

Kg

530I

532I

540I

541I

42

47

44

47

VED: 730I - 732I - 740I - 741I

20

1558
1533
1453

40

40

351
307

15

150

25

10

789
440

280
316

46
109

16

174

329

423
379

247
287
326

VED
Weight

Kg

730I

732I

740I

741I

58

58

61

61

The technical data in this document is not binding. Aermec S.p.A.


reserves the right to make any changes at any time deemed
necessary for product improvement.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

Cod.: SVEDI530_741UY.03/ 1503

1504
1509

55

VEC

Cassette type fancoil Coanda-effect


Installation in false ceilingsInstallation in false
ceilings

Aermec
participate in the EUROVENT program: FCH
the products are present on the site
www.eurovent-certification.com

Features

Reduced pressure drops across heat exchangers


For systems with fixed and variable delivery
EUROVENT certified
3-speed fan unit
Quiet operation
Motors with permanently connected condensers
Air filter easily removed and cleaned
Internal insulation and air filter of Class 1 fire
resistance
Removable shrouds for easy, effective cleaning

Reversibility of the water connections during


installation
Broad range of controls and accessories
Easy installation and maintenance
Full compliance with safety regulations
For possible heat mode functioning, refer to
the technical manual notes.

Compulsory accessories:
the following are essential for the functioning of the
units:
VEC_GL: air suction and delivery grille with adjustable Coanda-effect vents. White RAL 9010.
Accessories:
AMP: kit for wall-mounting installation.
BC5: auxiliary condensate drain tray.
BV: Single row hot water coil.
DSC4: condensate drainage device for use when
natural run-off is not possible.
SIT 3-5: thermostat interface cards. These allow you
to create a network of fan coils (max. 10), commanded from a centralised panel (selector or thermostat).
SIT3: commands the 3 fan speeds, and must be installed on each fan coil in the network; receives the commands from the selector or SIT5 card.
SIT5: commands the 3 fan speeds and up to 2 valves
(4-pipe systems); conveys the thermostat commands
to the fan coil network.

SW3: water temperature probe, allowing the implementation of automatic season changeover for those
electronic thermostats equipped with water side
changeover.
SWA: SWA external probe accessory (length L = 6m).
Detects the ambient air temperature if connected to
the connector (A) of the panel FMT21; in this case the
ambient air temperature probe built into the panel
will be automatically disabled. Detects the temperature of the water in the system to allow ventilation
consent if connected to the connector (W) of the
panel FMT21. Two SWA probes may be simultaneously connected to the panel FMT21.
VCF: kit consisting of a 3-way motorised valve, and
copper couplings and pipes. For 3-row and 1-row
coils (BV). Versions with 230V and 24V~50Hz power
supply.
VCFD: Kit consisting of a 2-way motorised valve, and
copper couplings and pipes. For 3-row and 1-row
coils (BV). Versions with 230V and 24V~50Hz power

supply.
Control panel and VMF system: the features of the
control panels are described in the relevant card.
Accessoires for heating mode
RX: Armoured electric coil with safety thermostat.
(Requires a thermostat with heater management).
PXAR: Electronic thermostat with thermostated or continuous ventilation.
PCR1: Galvanised plate protection for the controls and
the electrical element
BV: Single row hot water coil.
VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For
3-row.
VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3 row

VEC (Standard coil)


VEC (increased coil)

VEC (Standard coil)


VEC (increased coil)
Control panel
FMT10
FMT21
KTLP
PX2
PX2C6
PX
PXAE
TPF
TF1
WMT05
WMT06
WMT10
VMF-System
VMF-E4 / E4D
VMF-E0 / E1
VMF-E5B / E5N
VMF-SW
VMF-SW1

VEC: Fan coil for ambient air treatment


during the summer. The air is delivered into
the room via vents which, thanks to the
COANDA effect, make the air jet adhere to
the ceiling.
Installation in false ceilings
Compatible with VMF System
Grille with suction and adjustable delivery
vents with Coanda effect (compulsory accessory).
3-row coil

Accessoires

20
24

30
34

40
44

50
54

Compulsory accessoires

VEC20GL
VEC30GL
VEC40GL

BC5
DSC4
(1)
SIT3
SIT5
SW3
SWA
VCF41 (standard coil)
VCF42 (increased coil)
VCF4124 (standard coil)
VCF4224 (increased coil)
VCFD1 (standard coil)
VCFD2 (increased coil)
VCFD124 (standard coil)
VCFD224 (increased coil)

56

20
24

30
34

40
44

50
54

VEC (Standard coil)


20
24
VEC (increased coil)
Accessoires for heating mode
RX22
(2)

RX32
(2)
RX42
(2)
RX52
(2)
PXAR
(2)

PCR1
(2)

BV122
(2)

BV132
(2)
BV142
(2)
VCF44
(2)(3)

VCF4424
(2)(3)

VCFD4
(2)(3)

VCFD424
(2)(3)

30
34

40
44

50
54

(1) DSC4 The accessory is not compatible with the BC5,


and VMF system.
(2) See notes and warnings in the technical booklet
(3) only for accessory coil BV 1R

Technical data
Mod. VEC
COOLING PERFORMANCE

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

Total cooling capacity

Sensible cooling capacity

Water ow rate

Pressure drop

Air ow rate
Fans
Absorbed power
Max. input current
(2)
(2)
(2)
(3)
(3)
(3)

Sound power level

Sound pressure level


Water content
Coil connections

Vel.

20

24

30

34

40

44

50

54

W
W
W
W
W
W
l/h
l/h
l/h
kPa
kPa
kPa

H
M
L
H
M
L
H
M
L
H
M
L

m3/h
m3/h
m3/h
type
n
W
W
W
A
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
l

H
M
L

1320
1080
800
1080
880
640
227
186
138
5
4
2
247
167
130

1522
1076
877
1147
800
667
262
185
151
3
2
1
247
167
130

1950
1640
1370
1530
1280
1050
335
282
236
13
11
6
383
309
241

2980
2470
1980
2410
1980
1580
513
425
341
11
9
6
511
406
306

3907
3335
2552
2737
2421
1909
672
574
439
22
17
10
511
406
306

3610
3170
2350
2590
2270
1680
621
545
404
15
10
6
613
529
371

4282
4000
2995
2909
2437
1785
737
688
515
30
27
16
613
529
371

1
25
22
19
0,12
48
42
35
39,5
33,5
26,5
0,79
1/2"G
V3
V2
V1

1
25
22
19
0,12
48
42
35
39,5
33,5
26,5
0,79
1/2"G
V3
V2
V1

2
44
33
25
0,21
49
43
37
40,5
34,5
28,5
1,11
1/2"G
V3
V2
V1

2471
2140
1789
1775
1510
1257
425
368
308
8
6
5
383
309
241
centrifugal
2
44
33
25
0,21
49
43
37
40,5
34,5
28,5
1,11
1/2"G
V3
V2
V1
230V/1/50Hz

2
57
43
30
0,28
48
43
38
39,5
34,5
29,5
1,48
3/4"G
V3
V2
V1

2
57
43
30
0,28
48
43
38
39,5
34,5
29,5
1,48
3/4"G
V3
V2
V1

2
67
46
34
0,35
53
50
43
44,5
41,5
34,5
1,48
3/4"G
V3
V2
V1

2
67
46
34
0,35
53
50
43
44,5
41,5
34,5
1,48
3/4"G
V3
V2
V1

H
M
L
H
M
L
H
M
L

H
M
L

Speed connected
Power supply

H max. speed; M med. speed; L min. speed


Cooling mode (VEC 20 - 30 - 40 - 50 EUROVENT)
(1) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(3) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Heating
See notes and warnings in the technical booklet.
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)
VEC_GL (Compulsory accessory)
VEC30GL

VEC20GL

VEC40GL

62

15

595

595

595

15

595

1195

Dimensions VEC + VEC_GL (maximum dimensions)


C

Mod.
A

Height
Widht
Depth
Weight (VEC)
Weight (VEC_GL)

(A)
(B)
(C)

VEC
VEC
mm
mm
mm
kg
kg

20/24
20GL
283
595
595
15,5
3,7

30/34
30GL
283
895
595
20,6
5,7

40/44
40GL
283
1195
595
24,7
7

50/54
40GL
283
1195
595
24,7
7

40/44
40GL
283
574
1174

50/54
40GL
283
574
174

Cod.: SVECUY.04 / 1310

895

Dimensions VEC + VEC_GL (Dimensions for installation)

Mod.
A

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Height
Widht
Depth

(A)
(D)
(E)

VEC
VEC
mm
mm
mm

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

20/24
20GL
283
574
574

30/34
30GL
283
574
874

57

VEC_I

Cassette type fancoil Coanda-effect, with Brushless Inverter motor (EC)


Installation in false ceilings

Aermec
participate in the EUROVENT program: FCH
the products are present on the site
www.eurovent-certification.com

Features

VEC_I: Fan coil for ambient air treatment


during the summer. The air is delivered into
the room via vents which, thanks to the
COANDA effect, make the air jet adhere to
the ceiling.
Installation in false ceilings
Compatible with VMF System
Grille with suction and adjustable delivery
vents with Coanda effect (compulsory accessory).
Unit with standard coil (2050)

Unit with increased coil (2454)


Reduced pressure drops across heat exchangers
For systems with fixed and variable delivery
Fan unit with Brushless motor (continuous
0-100% speed variation)
Quiet operation
Air filter easily removed and cleaned
Internal insulation and air filter of Class 1 fire
resistance
Reversibility of the water connections during

installation
Broad range of controls and accessories
Easy installation and maintenance
Full compliance with safety regulations
For possible heat mode functioning, refer to
the technical manual notes.

Accessori
valve, and copper couplings and pipes. For
Compulsory accessories:
Accessories for heating mode
3-row and 1-row coils (BV). Versions with BV: Single row hot water coil.
the following are essential for the functio230V and 24V~50Hz power supply.
ning of the units:
VCF: the kit contains a motorised 3-way valve with
VEC_GL: air suction and delivery grille with VCFD: Kit consisting of a 2-way motorised
insulating shell, plus coupling and pipes in insulavalve, and copper couplings and pipes. For
adjustable Coanda-effect vents.
ted copper Versions with 230V and 24V~50Hz
3-row and 1-row coils (BV). Versions with
White RAL 9010.
power supply.
230V and 24V~50Hz power supply.
VCFD: Kit consisting of powered 2-way valve,
Accessories:
copper couplings and pipes. For 3 row. Versions
BC5: auxiliary condensate drain tray.
Control panel and VMF System: the characteristics
with 230V and 24V~50Hz power supply.
BV: Single row hot water coil.
are described on the appropriate card.
DSC4: condensate drainage device for use
when natural run-off is not possible.
VCF: kit consisting of a 3-way motorised

VEC_I (standard coil)


VEC_I (increased coil)
Compulsory accessories
VEC20GL
VEC30GL
VEC40GL

20
24

BC5
DSC4
(1)
VCF41 (standard coil)
VCF42 (increased coil)
VCF4124 (standard coil)
VCF4224 (increased coil)

30
34

40
44

50
54

VEC_I (standard coil)


VEC_I (increased coil)
VCFD1 (standard coil)
VCFD2 (increased coil)
VCFD124 (standard coil)
VCFD224 (increased coil)
Control panel
WMT20
VMF-System
VMF-E4 / E4D
VMF-E18
VMF-E5B / E5N

20
24

30
34

40
44

50
54

(1) DSC4 The accessory is not compatible with the basins BC5, and VMF system.
(2) See notes and warnings in the technical booklet.
(3) only for accessory coil BV 1R

58

VEC_I (standard coil)


VEC_I (increased coil)
VMF-SW
VMF-SW1

20
24

30
34

Accessory dedicated to heating mode


BV122
(2)

BV132
(2)

BV142
(2)
VCF44
(2)(3)

VCF4424
(2)(3)

VCFD4
(2)(3)

VCFD424
(2)(3)

40
44

50
54

Technical data
Mod. VEC_I
COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water ow rate

Pressure drop

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

Air ow rate
Fans
Absorbed power
Max. input current
(2)
(2)
(2)
(3)
(3)
(3)

Sound power level


Sound pressure level
Water content
Coil connections

Vel.

20I

24I

30I

34I

40I

44I

50I

54I

W
W
W
W
W
W
l/h
l/h
l/h
kPa
kPa
kPa

H
M
L
H
M
L
H
M
L
H
M
L

m3/h
m3/h
m3/h
type
n
W
W
W
A
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
l

H
M
L

1320
1080
800
1080
880
640
227
186
138
4,6
4
2
247
194
130

1522
1224
877
1147
908
667
262
211
151
3
2
1
247
194
130

1950
1640
1370
1530
1280
1050
335
282
236
13,3
11
6
383
309
241

2980
2470
1980
2410
1980
1580
513
425
341
11,3
9
6
511
406
306

3907
3335
2552
2737
2421
1909
672
574
439
22
16
9
511
406
306

3610
3170
2350
2590
2270
1680
621
545
404
14,8
10
6
613
529
371

4282
4154
2995
2909
2437
1785
737
714
515
30
28
18
613
529
371

1
12
8
5
0,11
48
42
35
39,5
33,5
26,5
0,79
1/2"G
5,4V
4,2V
2,6V

1
12
8
5
0,11
48
42
35
39,5
33,5
26,5
0,79
1/2"G
5,4V
4,2V
2,6V

2
10
10
10
0,11
49
43
37
40,5
34,5
28,5
1,11
1/2"G
5V
3,8V
2,8V

2471
2140
1789
1775
1510
1257
425
368
308
8
6
4
383
309
241
centrifugal
2
10
10
10
0,11
49
43
37
40,5
34,5
28,5
1,11
1/2"G
5V
3,8V
2,8V
230V/1/50Hz

2
17
9
6
0,14
48
43
38
39,5
34,5
29,5
1,48
3/4"G
5,1V
3,9V
2,8V

2
17
9
6
0,14
48
43
38
39,5
34,5
29,5
1,48
3/4"G
5,1V
3,9V
2,8V

2
37
20
8
0,3
53
50
43
44,5
41,5
34,5
1,48
3/4"G
6,1V
5,1V
3,4V

2
37
20
8
0,3
53
50
43
44,5
41,5
34,5
1,48
3/4"G
6,1V
5,1V
3,4V

H
M
L
H
M
L
H
M
L

H
M
L

Speed connected
Power supply

H max. speed; M med. speed; L min. speed


Cooling mode (VEC 20I - 30I - 40I - 50I EUROVENT)
(1) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(3) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Heating
See notes and warnings in the technical booklet.
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)
VEC_GL (Compulsory accessory)
VEC30GL

VEC20GL

VEC40GL

62

15

595

595

595

15

595

1195

Dimensions VEC_I + VEC_GL (maximum dimensions)


C

Mod.
A

Height
Widht
Depth
Weight (VEC_I)
Weight (VEC_GL)

(A)
(B)
(C)

VEC_I
VEC
mm
mm
mm
kg
kg

20/24
20GL
283
595
595
15,5
3,7

30/34
30GL
283
895
595
20,6
5,7

40/44
40GL
283
1195
595
24,7
7

50/54
40GL
283
1195
595
24,7
7

40/44
40GL
283
574
1174

50/54
40GL
283
574
174

Cod.: SVECIUY.09 / 1410

895

Dimensions VEC_I + VEC_GL (Dimensions for installation)

Mod.
A

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Height
Widht
Depth

(A)
(D)
(E)

VEC_I
VEC
mm
mm
mm

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

20/24
20GL
283
574
574

30/34
30GL
283
574
874

59

FCL

Cassette type fancoil


Ceiling and false ceiling installation, cooling power from 1900 up to 11000W
Models:
FCL 32 , FCL36 , FCL42 , FCL62 - FCL72
FCL 34 , FCL38 , FCL44 , FCL64

Models:
FCL 82 , FCL102 , FCL122
FCL 84 , FCL104 , FCL124

FCL with accessory FCLMC


Aermec
participate in the EUROVENT
program: FCH
the products are present on
the site
www.eurovent-certification.
com

GLL10 - GLL10M - GLL10R - GLL10N

GLL20 - GLL20R - GLL20N

White: RAL 9010

White: RAL 9010

FCLMC
White: RAL 9010

Remote Control included for GLL10M


GLL10R - GLL20R

4 CONFIGURATIONS ON ONE CASSETTE-TYPE FAN COIL:


- WITH MOTORISED LOUVERS THAT CAN BE ORIENTED VIA THE REMOTE CONTROL
(GLL10M ONLY)
- WITH LOUVERS THAT CAN BE ORIENTED MANUALLY, REMOTE CONTROL
- WITH LOUVERS THAT CAN BE ORIENTATED MANUALLY, WALL-MOUNTED CONTROL PANEL
- WITH MANUALLY ADJUSTABLE FINS, VMF SYSTEM ELECTRONIC THERMOSTAT,
WALL-MOUNTED CONTROL PANEL (VMF-E4), COMPLETE INTEGRATION WITH THE
VMF SYSTEM (ONLY WITH GLL10N AND GLL20N)
STANDARD INTERNAL 3-WAY VALVE, WITH FAST CONNECTION ACTUATOR AND
VISUAL POSITION SIGNALLING
VERSION WITH 2-WAY VALVE FOR VARIABLE WATER FLOW RATE SYSTEMS
VERSION WITHOUT VALVES
HEAT EXCHANGE COIL WITH SHAPED PROFILE AND ENHANCED SURFACE
FAN PURPOSELY DESIGNED FOR LOW SOUND EMISSIONS
VERSIONS FOR 2-PIPE AND 4-PIPE SYSTEMS
ALSO AVAILABLE WITH ELECTRIC HEATER FOR HEATING
Features
8 sizes for 2-pipe versions:
FCL 32-36-42-62-72-82-102-122
7 sizes for 4-pipe versions:
FCL 34-38-44-64-84-104-124
Standard preparation with standard internal
three-way valve, with fast connection actuator and position visual signalling.
FCL_V2 preparation (available upon request),
with internal two-way valve, suitable for
variable water flow rate systems.
FCL_VL preparation (available upon request),
without internal valve.
3 configurations on one cassette-type fan coil:
- louvers that can be oriented by means of a
remote control and electronic control if coupled with the accessory GLL10M;
- with remote control, louvers that can be
oriented manually and by means of electronic control if coupled with the accessory
GLL10R or GLL20R;
- with louvers that can be oriented manually
if coupled with the accessory GLL10 or
GLL20, also requires a wired control panel
(accessory).

60

High design aesthetics.


Grille dimensions perfectly integrable in standard suspended ceiling panels of
600x600mm and 840x840mm for the most
powerful units.
Fan designed for low sound emissions.
3-speed and 4-speed mixed flow (axial +
centrifugal) fan unit for larger sizes (FCL
42-44-62-64-72-82-84-102-104-122-124), in
order to select the 3 speeds that best meet
delivered power and quiet operation requirements.
The load-bearing structure, reinforced with a
galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of
noise reduction and air routing (FCL 42-4462-72-64).
Structure made entirely of galvanised steel,
containing insulation elements in closed cell
expanded polystyrene and externally covered
with anti-condensate felt (FCL 82-84-102104-122-124).
Condensation drip tray in one piece, with V0

self-extinguishing level and overmoulding to


insulation in expanded polystyrene with
flame retardant additive.
Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves.
Continuous fan operation to prevent stratification of room air.
Possibility of direct release of external air
regardless of indoor unit ventilation.
Possibility to control the climate of adjacent
rooms as well. The versions FCL 82-84-102104-122-124 allow 3-direction delivery.
Air filter easily removed and cleaned, selfsupporting structure, characterised by a high
efficiency and low pressure drops, with classV0 fire resistance (UL 94).
Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900),
(FEL 10 accessory for GLL10, GLL10R,
GLL10M).
Full compliance with safety regulations.
Easy installation and maintenance.

Accessories
Compulsary GLL accessories,
essential for unit operation:
GLL10M (600x600)
Delivery grille with adjustable louvers by
means of a remote control and air intake,
supplied with an infrared receiver with emergency operation switch.
White RAL 9010.
GLL10R (600x600)
GLL20R (840x840)
Delivery grille with louvers manually adjustable and air intake. With remote control, supplied with an infrared receiver with emergency operation switch. White RAL 9010.
GLL10 (600x600)
GLL20 (840x840)
Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010.
GLL10N (600x600)
GLL20N (840x840)
Delivery grille with Manually adjustable fins
and air intake, with "VMF System" advanced
electronic thermostat. Individual units, or network master also requires a wired control
panel (VMF-E4 compulsory accessory). White
RAL 9010.
Control panels and VMF System: the characteristics are described on the appropriate card.

Accessories:
FCLMC10
FCLMC20
is a perimeter case in galvanised and painted
sheet steel, which is used when the fan coil is
installed outside the suspended ceiling. It is
used for aesthetics and protection, therefore
the technical features of the FCL and FCLI
remain unvaried.
FEL10 : kit n5 electrostatically pre-charged
air filter, with fire resistance class 2 (UL 900).
KFL : Delivery flange, allowing the air to be
directed to an adjacent room.
KFL20 (***) : delivery flange, allowing the air
to be directed to an adjacent room. Up to
three KFL20 can be assembled on a single
unit.
KFLD : suction flange, allows to introduce
external air directly into the room without
mixing.
KFLD20 (***) : suction flange, allows to introduce external air directly into the room
without mixing. Up to two KFL20D can be
assembled on a single unit.
RXLE - RXLE20 : electric heater for heating,
can be installed on the single-fan FCL units.
Requires GLL-M or GLL-R.
SIT 3-5 : Thermostat Interface Cards. They
allow the creation of a network of fan coils
(max. 6) commanded by a central control
panel (selector or thermostat).
SIT3 : commands the 3 fan speeds and must

be installed on each fan coil of the network;


receives the commands from the selector or
the SIT5 card.
SIT5: commands the 3 fan speeds and up to 2
valves (four pipes systems); transmits the thermostat commands to the network of fan coils
fitted with SIT3.
SW3 : Minimum water temperature probe, to
be used with electronic PXAE thermostats.
SW4 : Minimum water temperature probe, to
be used with the units fitted with a grille with
remote control. Conpulsury with GLL_M,
GLL_R, GLL_N
SWA : External SWA probe accessory for
FMT21 panels. Detects the ambient air temperature if connected to the connector (A); the
probe in the panel will be automatically disabled. Detects the temperature of the water in
the system, for ventilation consent, if connected to the connector (W) (Length L = 6m)
VHL1 - VHL20 : motor-driven three-way valve
for the heating battery in 4-pipe systems.
Obligatory accessory in 4-pipe systems.
VHL2 - VHL22 : motor-driven two-way valve
for the heating battery in 4-pipe systems.
Obligatory accessory in 4-pipe systems with
variable flow rates.

Mod. FCL

32

34

36

38

42

44

62

64

72

82

84

102

104

122

124

GLL10

GLL10M
GLL10R
GLL10N

(1)
(1)
(1)

GLL20
GLL20R
GLL20N

(1)
(1)

FCLMC10
FCLMC20
FEL10
KFL
KFL20

(2)

KFLD
KFLD20
RXLE
RXLE20
SW3
SW4
SWA

(2)
(1)
(1)
(3)
(1)
(3)

VHL1
VHL20
VHL2
VHL22
SIT 3
SIT 5
FMT10
FMT21
PX
PX2- PX2C6
PXAE
TPF

WMT10
VMF-E4 / E4D

(3)
(3)
(3)
(3)
(3)
(3)(4)
(3)
(3)
(3)
(5)

(1) Compulsory with GLL_M, GLL_R, GLL_N


(2) A maximum of three KFL20 / KFL20D can be assembled on a single unit
(3) Accessories that can only be used in combination with GLL10 and GLL20 grilles.
(4) PX2C6 = Multiple package of n6 PX2 control panels
(5) Accessories that can only be used in combination with the GLL10N and GLL20N grilles for individual units or network master

61

Technical data
Mod.

FCL

Vel.

32

34

36

38

HEATING PERFORMANCE (2 PIPE CONFIGURATION)


3995
6270

W
H
Heating capacity (70C)
2946
4503

W
M
2221
3423

W
L
350
550

H
Water ow rate
258
395

M
195
300

L
10
19

W
H
Pressure drop
6
10

W
M
4
6

W
L
2380
3750

W
H
Heating capacity (50C)
1760
2690

W
M
1330
2050

W
L
327
516

H
Water ow rate
253
387

M
200
308

L
9
14

W
H
6
8

W
M
Pressure drop
4
5

W
L
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
2600
2600

W
H
Heating capacity (70C)
2190
2190

W
M
1950
1950

W
L
228
228

H
Water ow rate
192
192

M
171
171

L
11
11

W
H
Pressure drop
8
8

W
M
6
6

W
L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
1900 1900 3000 2770

W
H
Total cooling capacity
1470 1470 2250 2080

W
M
1160 1160 1790 1650

W
L
1520 1520 2400 2240

W
H
Sensible cooling capacity
1250 1250 1780 1660

W
M
990
990
1390 1300

W
L
327
327
516
476

H
Water ow rate
253
253
387
358

M
200
200
308
284

L
10
10
15
13

W
H
Pressure drop
7
7
9
8

W
M
4
4
6
5

W
L
600
600
600
600
H
3
Air ow rate
410
410
410
410
3
M
300
300
300
300
L
3

Fans
1
1
1
1
n
45
45
45
45
230V W
H
Absorbed power
31
31
31
31
230V W
M
21
21
21
21
230V W
L
Max. input current
0,22
0,22
0,22
0,22
230V A
46
46
46
46


H
Sound power level
38
38
38
38


M
35
35
35
35


L
37
37
37
37


H
Sound pressure level
29
29
29
29


M
26
26
26
26


L
Water content
1,2
1,2
1,5
1,5

Water content (additiona heat exchanger)


0,3
0,5

Coil connections
3/4"
3/4"
3/4"
3/4"

Coil connections (additiona heat exchanger)


1/2"
1/2"

V3
V3
V3
V3
H
Speed connected
V2
V2
V2
V2
M
V1
V1
V1
V1
L
Power supply

42

44

62

64

7335
4473
3319
643
392
291
24
10
6
4400
2690
2000
679
437
337
23
10
6

10487
6373
5192
920
559
455
42
17
12
6250
3830
3100
857
552
458
32
15
10

2730
2290
1960
240
201
172
12
8
6

3570
2810
2480
313
247
218
22
15
12

3950
2540
1960
3160
1820
1380
679
437
337
25
11
7
700
360
260

3000
2340
1810
2180
1680
1270
516
402
311
15
10
6
700
360
260

4980
3210
2660
3810
2270
1860
857
552
458
36
16
12
880
500
380

1
75
32
22
0,33
53
38
35
44
29
26
1,5
3/4"
V4
V2
V1

1
47
32
22
0,33
46
38
35
37
29
26
1,5
0,5
3/4"
1/2"
V4
V2
V1

72

82

84

102

104

122

124

17727
11714
8295
1555
1028
728
25
12
6
10600
7000
4950
1548
1015
697
25
12
6

21747
14729
10531
1908
1292
924
42
21
11
13000
8800
6300
1892
1290
922
34
17
9

8500
6400
5300
746
561
465
14
9
6

10000
7300
5900
877
640
518
19
11
7

12500
9300
7050
1097
816
618
29
17
10

6000
4050
2800
4200
2770
1900
1032
697
482
25
12
6
1100
680
460

6000
4050
2800
4200
2770
1900
1032
697
482
25
12
6
1100
680
460

9000
5900
4050
6660
4300
2940
1548
1015
697
28
13
7
1350
830
560

7200
4920
3500
5300
3530
2480
1238
846
602
26
13
7
1350
830
560

11000
7500
5360
8470
5730
4040
1892
1290
922
38
19
10
1750
1100
750

8800
6220
4570
6770
4670
3370
1514
1070
786
38
22
10
1750
1100
750

1
150
80
45
0,7
50
43
39
41
34
30
3,0
3/4"
V4
V2
V1

1
150
80
45
0,7
50
43
39
41
34
30
3,0
1,5
3/4"
1/2"
V4
V2
V1

1
155
80
50
0,7
54
45
40
45
36
31
4,5
3/4"
V4
V2
V1

1
155
80
50
0,7
54
45
40
45
36
31
4,5
1,5
3/4"
1/2"
V4
V2
V1

1
175
105
55
0,75
60
50
44
51
41
35
4,5
3/4"
V4
V2
V1

1
175
105
55
0,75
60
50
46
51
41
37
4,5
1,5
3/4"
1/2"
V4
V2
V1

11321 11877
7571 8118
6143 5875
993
1042
664
712
539
515
42
26
20
13
14
7
6750 7100
4490 4850
3650 3500
939
1032
576
697
482
482
38
23
16
11
11
6
-

4610 5460
2970 3350
2460 2800
3530 4100
2100 2350
1720 1890
793
939
511
576
423
482
35
43
16
18
11
13
880
900
500
520
380
400
centrifugal
1
1
1
83
101
110
37
45
58
26
32
50
0,37
0,45
0,52
61
61
60
47
47
49
41
41
43
52
52
51
38
38
40
32
32
34
2,1
2,1
2,1
0,6
3/4"
3/4"
3/4"
1/2"
V4
V4
V4
V2
V2
V2
V1
V1
V1
230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=100m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

62

Dimensions (mm)
FCL 32 - 34 - 36 - 38 - 42 - 44 - 62 - 64 - 72
FCL 32 V2 - 34 V2 - 36 V2 - 38 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2 - 72 V2
FCL 32 VL - 34 VL - 36 VL - 38 VL - 42 VL - 44 VL - 62 VL - 64 VL - 72 VL

Mod. FCL
Weight

kg

32
20,5

34
21

36
20,5

38
21

42
20,5

44
21

62
22

64
22,5

72
22,5

kg

32 V2
20,5

34 V2
21

36 V2
20,5

38 V2
21

42 V2
20,5

44 V2
21

62 V2
21

64 V2
22,5

72 V2
22,5

kg

32 VL
20

34 VL
20,5

36 VL
20

38 VL
20,5

42 VL
20

44 VL
20,5

62 VL
21,5

64 VL
22

72 VL
22

Mod. FCL
Wheigt

Mod. FCL
Weight

FCL 82 - 84 - 102 - 104 - 122 - 124


FCL 82 V2 - 84 V2 - 102 V2 - 104 V2 - 122 V2 - 124 V2
FCL 82 VL - 84 VL - 102 VL - 104 VL - 122 VL - 124 VL

GLL20N

Mod. FCL
Weight

kg

82
35

84
36

102
36

104
36

122
36

124
36

kg

82 V2
35

84 V2
36

102 V2
36

104 V2
36

122 V2
36

124 V2
36

kg

32 VL
34

34 VL
35

102 VL
35

104 VL
35

122 VL
35

124 VL
35

Mod. FCL
Weight

Mod. FCL
Weight

All specifications are subject to change without prior notice.


Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

Cod.: SFCLUY.11 / 1501

GLL20N

63

FCLI

Cassette-type fancoils with Brushless Inverter motor (EC)


Continuous 0-100% air flow rate regulation
Ceiling and false ceiling installation, cooling power from 1900 up to 11000W

Models:
FCLI32 , FCLI42 , FCLI62
FCLI34 , FCLI44 , FCLI64

Models:
FCLI82 , FCLI122 , FCLI124
FCLI with accessory FCLMC

Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

GLLI10 - GLLI10N
White: RAL 9010

GLLI20 - GLLI20N
White: RAL 9010

FCLMC
White: RAL 9010

ENERGY SAVINGS OF 50% COMPARED WITH A FAN


COIL WITH TRADITIONAL 3-SPEED MOTOR
VERY QUIET OPERATION
TOTAL COMFORT: REDUCED TEMPERATURE AND
HUMIDITY VARIATIONS IN THE AIR-CONDITIONED
ROOMS
STANDARD INTERNAL THREE-WAY VALVE, WITH FAST
CONNECTION ACTUATOR AND POSITION VISUAL
SIGNALLING
VERSION WITH 2-WAY VALVE FOR VARIABLE WATER
FLOW RATE SYSTEMS
VERSION WITHOUT VALVES
Features
Fan unit with Brushless motor (Continuous
0-100% speed variation);
5 sizes for 2-pipe versions:
FCLI 32-42-62-82-122
4 sizes for 4-pipe versions:
FCLI 34-44-64-124
Standard preparation with standard internal
three-way valve, with fast connection actuator and visual signalling of the position
FCLI_V2 preparation (available upon request),
with internal two-way valve, suitable for variable water flow rate systems
FCLI_VL preparation (available upon request),
without internal valve
Requires matching with the obligatory accessories, grill and control panel, necessary for
the operation

64

High design aesthetics


Grille dimensions that can be perfectly incorporated into standard suspended ceiling
panel sizes (600x600 mm) and (840X840) for
more powerful units.
Fan for low sound emissions
EUROVENT certification
The load-bearing structure, reinforced with a
galvanised steel side band, contains insulation elements in expanded polystyrene
obtained from injection moulding for purposes of noise reduction and air routing
The condensation drip tray is in one piece,
with V0 self-extinguishing level and joined by
means of over-moulding technology to the
insulation in expanded polystyrene with
flame retardant additive

Heat exchanger with shaped profile to


increase the exchange surface, and easily
accessible drain valves
Possibility of direct release of external air
regardless of indoor unit ventilation
Air filter easily removed and cleaned, selfsupporting structure, characterised by a high
efficiency and low pressure drops, with a fire
resistance class V0 (UL 94)
Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900), (FEL
10 accessory)
Full compliance with the accident prevention
standards
Ease of installation and maintenance

Accessories
Obligatory accessories, essential for unit VMF-E4 : Control panel VMF System with
operation:
electronic thermostat and LCD monitor. Wallmounting
GLLI10 (600x600)
SW4 : Water temperature probe for the control
GLLI20 (840x840)
of maximum / minimum temperature (2-pipe
Delivery grille with louvers manually adjustasystem) or for the control of minimum temperble and air intake. Combined with wallature in the heating coil (4-pipe system)
mounted control panel. White RAL 9010.
VMF-SW1 : Water temperature probe for the
WMT20 : Control panel with electronic thercontrol of maximum temperature in the coolmostat and LCD monitor. Wall mounting.
ing coil (4-pipe system)
SWI : Water temperature probe for WMT20
Control panels and VMF System: the charactercontrol panels. Cable length L = 2m.
istics are described on the appropriate card.
GLLI10N (600x600)
Accessories:
GLLI20N (840x840)
Delivery grille without water probe, with FCLMC10
Manually adjustable fins and air intake, with
FCLMC20 : is a perimeter case in galvanised
"VMF System" advanced electronic thermostat.
and painted sheet steel, which is used when
Individual units, or network master also requires
the fan coil is installed outside the suspended
a wired control panel (VMF-E4 compulsory
ceiling. It is used for aesthetics and protecaccessory). White RAL 9010.
tion, therefore the technical features of the

Mod. FCLI
GLLI10
GLLI20
WMT20
GLLI10N
GLLI20N
VMF-E4 *
FCLMC10
FCLMC20 **
FCLMC20IK **
FEL10
KFL
KFL20
KFLD
KFLD20
VHL1
VHL2
SWI
SW4 *
VMF-SW1 *

Compatibility of accessories
44
62

32

34

42

64

FCL and FCLI remain unvaried. FCLMC20


requires the combination with the
FCLMC20IK accessory.
FCLMC20IK : Installation kit for Controller
Inverter, compulsory for units with FCLM20.
FEL10 : electrostatically pre-charged air filter,
regenerated with fire resistance class 2 (UL 900).
KFL10
KFL20 : Delivery flange, allowing the air to
be directed to an adjacent room.
KFLD
KFLD20 : suction flange, allows to introduce
external air directly into the room without
mixing.
VHL1 : motor-driven three-way valve for the
heating battery in 4-pipe systems. Obligatory
accessory in the 4-pipe systems.
VHL2 : motor-driven two-way valve for the heating battery in 4-pipe systems. Obligatory accessory for 4-pipe systems with variable flow rates.

82

122

124

* Accessory for GLLI_N


** FCLMC20 requires the combination with the FCLMC20IK accessory

65

Technical data
Mod.

FCLI

Vel.

32

34

HEATING PERFORMANCE (2 PIPE CONFIGURATION)


(1)
W
H
3995
Heating capacity (70C)
(1)
W
M
2946
(1)
W
L
2221
(1)
l/h
H
350
Water ow rate
(1)
l/h
M
258
(1)
l/h
L
195
(1)
kPa
H
10
Pressure drop
(1)
kPa
M
6
(1)
kPa
L
4
(2)
W
H
2380
Heating capacity (50C)
(2)
W
M
1760
(2)
W
L
1330
(2)
l/h
H
327
Water ow rate
(2)
l/h
M
253
(2)
l/h
L
200
(2)
kPa
H
9
(2)
kPa
M
6
Pressure drop
(2)
kPa
L
4
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3)
W
H
2600
Heating capacity (70C)
(3)
W
M
2190
(3)
W
L
1950
(3)
l/h
H
228
Water ow rate
(3)
l/h
M
192
(3)
l/h
L
171
(3)
kPa
H
11
Pressure drop
(3)
kPa
M
8
(3)
kPa
L
6
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4)
W
H
1900
1900
Total cooling capacity
(4)
W
M
1470
1470
(4)
W
L
1160
1160
(4)
W
H
1520
1520
Sensible cooling capacity
(4)
W
M
1250
1250
(4)
W
L
990
990
(4)
l/h
H
327
327
Water ow rate
(4)
l/h
M
253
253
(4)
l/h
L
200
200
(4)
kPa
H
10
10
Pressure drop
(4)
kPa
M
7
7
(4)
kPa
L
4
4
m3/h
H
600
600
m3/h
Air ow rate
M
410
410
L
300
300
m3/h
type
Fans
n
1
1
W
H
18
18
Absorbed power
W
M
13
13
W
L
10
10
Max. input current
(A)
0,28
0,28
(5)
dB(A)
H
46
46
(5)
dB(A)
M
38
38
Sound power level
(5)
dB(A)
L
35
35
(6)
dB(A)
H
37
37
(6)
dB(A)
M
29
29
Sound pressure level
(6)
dB(A)
L
26
26
l
1,2
1,2
Water content
Water content (additiona heat exchanger)
l
0,3
Coil connections

3/4"
3/4"
Coil connections (additiona heat exchanger)

1/2"
%
H
90
90
Percentage of work than the signal
M
62
62
%
conguration
L
42
42
%

Power supply

42

44

62

64

82

122

124

7335
4473
3319
643
392
291
24
10
6
4400
2690
2000
679
437
337
23
10
6

10487
6373
5192
920
559
455
42
17
12
6250
3830
3100
857
552
458
32
15
10

11877
8118
5875
1042
712
515
26
13
7
7100
4850
3500
1032
697
482
23
11
6

21747
14729
10531
1908
1292
924
42
21
11
13000
8800
6300
1892
1290
922
34
17
9

2730
2290
1960
240
201
172
12
8
6

3570
2810
2480
313
247
218
22
15
12

12500
9300
7050
1097
816
618
29
17
10

3950
2540
1960
3160
1820
1380
679
437
337
25
11
7
700
360
260

3000
2340
1810
2180
1680
1270
516
402
311
15
10
6
700
360
260

4610
2970
2460
3530
2100
1720
793
511
423
35
16
11
880
500
380

6000
4050
2800
4200
2770
1900
1032
697
482
25
12
6
1100
680
460

11000
7500
5360
8470
5730
4040
1892
1290
922
38
19
10
1750
1100
750

8800
6220
4570
6770
4670
3370
1514
1070
786
38
22
10
1750
1100
750

1
55
16
12
0,43
53
38
35
44
29
26
1,5
3/4"
90
46
34

1
55
16
12
0,43
46
38
35
37
29
26
1,5
0,5
3/4"
1/2"
90
46
34

4980
3210
2660
3810
2270
1860
857
552
458
36
16
12
880
500
380
centrifugal
1
61
20
14
0,47
61
47
41
52
38
32
2,1
3/4"
90
52
40
230V/1/50Hz

1
61
20
14
0,47
61
47
41
52
38
32
2,1
0,6
3/4"
1/2"
90
52
40

1
33
14
9
0,71
50
43
39
41
34
30
3,0
3/4"
90
54
38

1
135
33
16
0,80
60
50
44
51
41
35
4,5
3/4"
90
58
38

1
135
33
16
0,80
60
50
46
51
41
37
4,5
1,5
3/4"
1/2"
90
58
38

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20C b.s.; Inlet water temperature 70C; T water 10C
Cooling mode (EUROVENT)
(4) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=100m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

66

Dimensions (mm)
FCLI 32 - 34 - 42 - 44 - 62 - 64
FCLI 32 V2 - 34 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2
FCLI 32 VL - 34 VL - 42 VL - 44 VL - 62 VL - 64 VL

GLLI 10
GLLI 10N

GLLI 10
GLLI 10N
Mod. FCLI
Weight

kg

32
20,5

34
21

42
20,5

44
21

62
22

64
22,5

Mod. FCLI
Weight

kg

32 V2
20,5

34 V2
21

42 V2
20,5

44 V2
21

62 V2
21

64 V2
22,5

Mod. FCLI
Weight

kg

32 VL
20

34 VL
20,5

42 VL
20

44 VL
20,5

62 VL
21,5

64 VL
22

FCLI 82 - 122 - 124


FCLI 82 V2 - 122 V2 - 124 V2
FCLI 82 VL - 122 VL - 124 VL

FCLI

GLLI
20
GLLI20
GLLI 20N

Mod. FCLI
Weight

kg

82
35

122
36

124
36

Mod. FCLI
Weight

kg

82 V2
35

122 V2
36

124 V2
36

Mod. FCLI
Weight

kg

32 VL
34

122 VL
35

124 VL
35

All specifications are subject to change without prior notice.


Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293577
www.aermec.com

Cod.: SFCLIUY.07/ 1501

GLLI
20
GLLI20
GLLI 20N

67

FCW

Fan coils
Wall-mount installation

Aermec
is participating in the EUROVENT Program: FCH
The related products can be found at the website
www.eurovent-certification.com

VERSIONS WITH INTERNAL 2- OR 3-WAY VALVE


QUICK AND EASY INSTALLATION
COMPACT DIMENSIONS
Features
By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.

Sale code description:


Code
FCW

Size
21-31-41

Valve
2V (with internal 2-way valve)
3V (with internal 3-way valve)
VL (without valve)

FCW is a fan coil model for wall-mount


installations, whose elegance and reduced
dimensions make it aesthetically pleasing; this
terminal is thus suitable for applications in
residential or light commercial sectors.
The product is configurable and available with
or without (2- or 3-way) valve, as well as with
or without control board, which ensures
compatibility with various system
requirements.
Fan coils without control board must be
necessarily combined with an external control
device.

Microprocessor control
(Empty) with control board
N without control board

Cream Colour
Display on the front panel
Three-speed cross flow fan
Maximum silence
Aesthetically styled with flat panel
Air flow louvered fins with horizontal
adjustment facility
Motorised deflector louvers that can be
activated by remote control TLW2 and remote
panel PFW2 for vertical orientation of the
outlet air with 4 fixed positions and continuous
oscillation
Timer for programming switch-off or switchon (TLW2 and PFW2)

Program for operation in automatic, cooling,


heating, ventilation and air ionising mode
(TLW2 and PFW2);
Night time Well-being Program (TLW2)
Automatic season change (TLW2 and PFW2)
Automatic re-start after power cut (TLW2 and
PFW2)
Easy installation and maintenance.
Air filter with easy extraction and cleaning
Full compliance with accident-prevention
standards.

Remote control TLW2


(mandatory accessory for versions with
controller FCW_2V, FCW_3V, FCW_VL):
This accessory is required for operating the fan
coil as an alternative to the wired remote
control panel PFW2; it is not possible to use
two remote control models at the same time.
Infrared remote control with liquid crystal
display for controlling all unit functions.
The remote control is delivered separately from
the fan coil; with a single remote control it is
possible to control more than one fan coil.
The remote control is equipped with a support
that allows you to hang it on the wall, from
which it can be operated without having to be
removed.

Wired control panel PFW2


(mandatory accessory for versions with
controller FCW_2V, FCW_3V, FCW_VL):
This accessory is required for operating the fan
coil as an alternative to the wired remote
control panel TLW2; it is not possible to use
two remote control models at the same time.
The PFW2 panel can control only one fan coil.
The panel must be wall-mounted and
connected to the fan coil using the 7.5-metre
long cable provided.

Accessories
For models with control board installed
FCW_2V, 3V, VL it is mandatory to select
among the user interfaces designed for the
FCW series (TLW2 or PFW2)
For models without control board installed
FCW_2VN, 3VN, VLN a user interface must be
mounted outside the fan coil, using either a
visible or a recessed wall-mount installation.
To make the selection, please refer to the
"control panels" or "VMF system" sheets, where
you will find comprehensive information on
this topic.

68

Technical data
Mod.
FCW
Speed
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
H
Thermal power (70C)
(1)
W
M
(1)
W
L
(1)
l/h
H
Water ow rate
(1)
l/h
M
(1)
l/h
L
(1)
kPa
H
Pressure drops
(1)
kPa
M
(1)
kPa
L
(2)
W
H
(2)
W
M
Thermal power (50C)
(2)
W
L
(2)
l/h
H
Water ow rate
(2)
l/h
M
(2)
l/h
L
(2)
kPa
H
(2)
kPa
M
Pressure drops
(2)
kPa
L
COOLING PERFORMANCE
(3)
W
H
Total cooling capacity
(3)
W
M
(3)
W
L
(3)
W
H
Sensitive cooling capacity
(3)
W
M
(3)
W
L
(3)
l/h
H
Water ow rate
(3)
l/h
M
(3)
l/h
L
(3)
kPa
H
Water pressure drops
(3)
kPa
M
(3)
kPa
L
H
m3/h
Air ow rate
m3/h
M
m3/h
L
type
fans
n
W
H
W
M
Input power
W
L
Maximum input current
(A)
(4)
dB(A)
H
Sound power
(4)
dB(A)
M
(4)
dB(A)
L
(5)
dB(A)
H
Sound Pressure
(5)
dB(A)
M
(5)
dB(A)
L
Water content
l
Coil connections
Gas (F)
H
Speeds connected
M
L
Electric power supply

212V

213V

21VL

312V

313V

31VL

412V

413V

41VL

4031
3020
2353
354
265
206
9
14
24
2400
1800
1400
327
249
189
21
13
8

4031
3020
2353
354
265
206
9
14
24
2400
1800
1400
327
249
189
21
13
8

4297
3660
2852
377
321
250
9
6
4
2560
2180
1700
353
299
236
8
6
4

5035
4363
3256
442
383
286
29.4
22.7
13.4
3000
2600
1940
413
358
267
26
20
12

5035
4363
3256
442
383
286
29.4
22.7
13.4
3000
2600
1940
413
358
267
26
20
12

5245
4515
3734
460
396
328
15.9
12.1
8.6
3120
2690
2220
430
370
306
14
10
7

7972
7234
6294
699
635
552
32
27
21
4750
4310
3750
654
593
516
28
24
18

7972
7234
6294
699
635
552
32
27
21
4750
4310
3750
654
593
516
28
24
18

8560
7846
6444
751
688
565
26
22
16
5100
4670
3840
702
643
528
23
19
14

1900
1450
1100
1550
1200
920
327
249
189
23
14
9
380
330
270

1900
1450
1100
1550
1200
920
327
249
189
23
14
9
380
330
270

2050
1740
1370
1730
1470
1160
353
299
236
9
7
5
389
340
280

2400
2080
1550
1970
1680
1280
413
358
267
29
22
13
440
390
320

2500
2150
1780
2040
1820
1510
430
370
306
15
11
8
446
400
330

3800
3450
3000
2850
2500
2010
654
593
516
32
27
21
540
470
370

3800
3450
3000
2850
2500
2010
654
593
516
32
27
21
540
470
370

4080
3740
3070
3470
3100
2590
702
643
528
26
21
15
684
602
476

1
27
24
23
0.13
53
48
42
44.5
39.5
34.0

1
27
24
23
0.13
53
48
42
44.5
39.5
34.0

1
27
24
23
0.13
53
48
42
44.5
39.5
34.0

1
27
23
22
0.13
53
48
42
44.5
39.5
34.0

2400
2080
1550
1970
1680
1280
413
358
267
29
22
13
440
390
320
tangential
1
27
23
22
0.13
53
48
42
44.5
39.5
34.0

1
27
23
22
0.13
53
48
42
44.5
39.5
34.0

1
48
41
31
0.23
54
49
44
45.5
40.5
35.5

1
48
41
31
0.23
54
49
44
45.5
40.5
35.5

1
48
41
31
0.23
54
49
44
45.5
40.5
35.5

F
V3
V2
V1

F
V3
V2
V1

F
V3
V2
V1

F
V3
V2
V1

F
V3
V2
V1
230V/1/50Hz

F
V3
V2
V1

F
V3
V2
V1

F
V3
V2
V1

F
V3
V2
V1

H maximum speed; M medium speed; L minimum speed


Heating
2-pipe system configuration
(1) Ambient air temperature 20C d.b.; Inlet water temperature 70C; 'T water 10C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20C d.b.; Inlet water temperature 50C; Water flow rate the same as in Cooling mode
Cooling (EUROVENT)
(3) Ambient air temperature 27C d.b./19C w.b.; Inlet water temperature 7C; 'T water 5C
(4) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard
(5) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m
Note: The speeds connected can differ from the factory standard configuration, for more information refer to the selection program and to the technical documentation
available at www.aermec.com

Code: SFCW3VUY.07/1501

Dimensional data (mm)


C

FCW
Height
Width
Depth
Weight

A
B
C
kg

21
298
880
205
9

31
305
990
210
10

41
360
1172
220
19

TLW2 accessory
Aermec reserves the right to make all the modifications deemed
necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

PFW2 accessory

69

FHX

Fan coils
With germicidal lamp

Aermec
participate in the EUROVENT
program: FCH
the products are present on the site
www.eurovent-certification.com

FHX
UVP
FHX-UVP
FHX-UVPO
FHX-UV
X-UV
Cabinet RAL 9002
heatboard RAL 7044

GERMICIDAL LAMP INCORPORATED


ESSENTIAL IN ENVIRONMENTS THAT REQUIRE THE
HIGHEST LEVELS OF HYGIENE
3 ROW COIL
The FHX fan coil is fitted with an exclusive
device for air sterilization, making it
essential in environments that require the
highest levels of hygiene, such as:

hospitals
dentists' surgeries
doctors' and vets' surgeries
analysis laboratories
pharmaceutical companies

waiting rooms
beauty institutes
homes
offices
public premises

Features
Versions:
FHX-UV:
universal free-standing or wall/ceiling mounting.
FHX-UVP: wall-mounted model without cabinet.
FHX-UVPO: wall-mounted model without cabinet, with boosted motor at 6/7
speeds (3 selectable).
Compatible with VMF System.
Exclusive air sterilization system with germicidal lamps. Efficiency of 99.999% in the deactivation of all microorganism Gram - and
Gram +

70

3 row coil.
3-speed ventilating unit.
Full compliance with the accident prevention
standards.
Rounded line.
Quiet operation.
Low loss of charge in the heat exchange batteries.
Electric motors with permanently inserted
condensers.
Ease of installation and maintenance.
Air filter easy to remove and clean.
Control made by a microprocessor thermostat

supplied as an accessory:
- FHX-UVP and UVPO: requires external control panel.
- FHX-UV: The control panel may be fitted on
board the unit or externally.
FHX-UV: Metal protection cabinet with varnishing in anticorrosion polyester, colour
RAL9002.
FHX-UV: The air delivery and suction louvers
are made of plastic material, colour RAL7044
Adjustable air delivery louver on version UV
except models 62 and 82.

Accessories

AMP20: kit for the wall mounting installation


BC: Auxiliary condensate drip tray.
GA: Intake louver with fixed slats.
GAF: Intake louver with fixed slats and filter.
GM: Delivery louver with adjustable slats.
PA: Intake Plenum made of galvanized steel
sheet, provided with Intake Connections for
Circular Section Ducts.
PA-F: Intake plenum that allows to have the
intake and the delivery on the same side, suitable for all the installations where it is
requested to put the appliance outside the airconditioned rooms in order to reduce to the
minimum the noise and facilitate the maintenance operations.
PC: Rear cover panel. Conveniently covers
exposed rear fancoil sections. The panel is
required by current safety standards for units
installed away from the room wall.
PM: Delivery plenum in galvanized steel with
external insulation, with plastic outlet connections for circular section ducting.
RD: Delivery straight duct connection.
RDA: Intake straight duct connection.
RP: Delivery 90 duct connection.

Accessories
AMP

BC

GA

GAF

GM

PA

PA

PC

PM

PXAE
PXAI

RPA: Intake 90 duct connection.


SE: Manually operated fresh air intake louver.
SIT 3-5: Thermostat interface cards. They
allow to set up a fancoils network (max. 10)
commanded by a centralised panel (switch or
thermostat).
SIT3: commands the three speeds of the fan
and must be installed on each fancoil of the
network; it receives the commands from the
switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to
two valves (four-pipe systems); it sends the
thermostat commands to the fancoils network.
SW: Probe for the electronic thermostats
which permits operation of the unit only with
water above 35 C.
VCF: The SW3 probe must be combined to
this accessory.
Kit complete with copper connections and 3
way valves all or nothing type, to be powered by
a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.
Attention: The VCF valve and the drip tray
BC4 can be installed at the same time as the
fan coil.

Size (FHX)
50
62
82

22

32

42

20

4
5
6
8
9
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22F
32F
42F
62F
23
33
43
62
22
32
42
62

(1)
(1)

(2)
(2)

VCFD: The SW3 probe must be combined to


this accessory.
Kit complete with copper connections and 2
way valves all or nothing type, to be powered
by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.
Attention: The VCFD valve and the drip tray
BC4 can be installed at the same time as the
fan coil.
ZX: Feet for built-in installation.
Compulsory accessories to choose from
PXAE: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or
automatic control). Continuous or thermostated ventilation. Wall installation.
PXAI: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or
automatic control). Water temperature sensor
included.
Control panels and VMF System: the characteristics are described on the appropriate
card.

Accessories
Versions
UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV
UV
UV
UV
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV-UVP-UVPO
UV

22
RD

RDA

RP

RPA

SE

22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
20X
30X
40X
80X

SIT3
SIT5
SW3
41
42
43
VCF
4124
4224
4324
1
2
3
VCFD
124
224
324
7
ZX
8

32

42

Size (FHX)
50
62
82

(3)
(3)
(3)
(3)

Versions
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UVP-UVPO
UVP-UVPO

(1) BC8 and BC9 are not applicable to fan coils with cover cabinets
(2) compulsory accessory
(2) SE accessories are matched with ZX feet

71

Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1)
W
(1)
W
Heating capacity (70C)
(1)
W
(1)
l/h
(1)
l/h
Water ow rate
(1)
l/h
(1)
kPa
(1)
kPa
Pressure drop
(1)
kPa
(2)
W
(2)
W
Heating capacity (50C)
(2)
W
(2)
l/h
(2)
l/h
Water ow rate
(2)
l/h
(2)
kPa
(2)
kPa
Pressure drop
(2)
kPa
COOLING PERFORMANCE
(3)
W
(3)
W
Total cooling capacity
(3)
W
(3)
W
(3)
W
Sensible cooling capacity
(3)
W
(3)
l/h
(3)
l/h
Water ow rate
(3)
l/h
(3)
kPa
(3)
kPa
Pressure drop
(3)
kPa
m3/h
m3/h
Air ow rate
m3/h
type
Fans
n
W
W
Absorbed power
W
W
Absorbed power with
W
germicidal lamp
W
A
Total input power (UV/UVP)
A
Total input power (UVPO)
(4)
dB(A)
(4)
dB(A)
Sound power level
(4)
dB(A)
(5)
dB(A)
(5)
dB(A)
Sound pressure level
(5)
dB(A)
l
Water content

Coil connections

Speed connected
Power supply

Vel.

FHX22

FHX32

FHX42

FHX50

FHX62

FHX82

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

2960
2531
1906
260
222
167
6
4
3
1770
1510
1130
258
210
144
6
5
2

5354
4065
3165
470
357
278
20
12
8
3160
2400
2060
413
316
267
16
10
7

9918
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
15
13
8

8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
604
432
15
11
6

12919
10942
8327
1133
960
730
17
12
7
7500
6430
4880
836
752
554
9
7
4

15140
13349
10771
1328
1171
945
21
16
11
7960
6860
5200
1189
860
738
21
12
9

H
M
L
H
M
L
H
M
L
H
M
L
H
M
L

1500
1220
840
1240
1000
670
258
210
144
6
5
3
290
220
140

2400
1840
1550
1900
1570
1110
413
316
267
28
17
13
450
350
260

3400
2780
2310
2760
2110
1630
585
478
397
14
10
7
600
460
330

4190
3510
2510
3000
2540
1790
721
604
432
19
14
8
720
600
400

4860
4370
3220
3980
3300
2440
836
752
554
17
14
8
920
720
520

6910
5000
4290
5680
3780
2970
1189
860
738
22
12
9
1140
930
700

1
25
22
19
50
47
44
0,12
0,37
50
43
31
42
35
23
0,79
1/2"
V3
V2
V1

2
44
33
25
69
58
50
0,21
0,57
48
41
34
40
33
26
1,11
1/2"
V3
V2
V1

2
57
43
30
82
68
55
0,28
0,63
51
44
37
43
36
29
1,48
3/4"
V3
V2
V1

2
67
46
34
92
71
59
0,35
0,48
56
51
42
48
43
34
1,48
3/4"
V3
V2
V1

3
82
61
40
182
161
140
0,4
0,92
57
51
42
49
43
34
2,52
3/4"
V3
V2
V1

3
106
80
59
206
180
159
0,49
1,06
61
56
51
53
48
43
2,52
3/4"
V3
V2
V1

Centrifugal
H
M
L
H
M
L

H
M
L
H
M
L

H
M
L

230V/1/50Hz

H max. speed; M med. speed; L min. speed


Heating mode
2 pipes system configuration
(1) Room air temperature 20C b.s.; Inlet water temperature 70C; 'T water 10C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperature 50C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperature 7C; 'T water 5C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

72

Dimensions and Weight


wall-mounted model with cabinet

wall-mounted model without cabinet

universal free-standing or wall/ceiling mounting with cabinet


B

universal free-standing or wall/ceiling


mounting without cabinet
C
D
B

FHX22-32-42-50UV

Mod FHX_UV
Height
Widht
Depth
Weight

A
B
C

Mod FHX_UVP/UVPO
Height
A
B
Widht
D (6)
Depth
C
Weight

FHX62-82UV

FHX22-32-42-5062-82UVP/UVPO

mm
mm
mm
kg

22
520
750
220
16

32
520
980
220
26

42
520
1200
220
25

50
520
1200
220
25

62
590
1320
220
35

82
590
1320
220
35

mm
mm
mm
mm
kg

22
453
522
572
216
16

32
453
753
823
216
26

42
453
973
1043
216
25

50
453
973
1043
216
25

62
453
1122
1205
216
35

82
453
1122
1205
216
35

Cod.: SFHXUY.07 / 1501

(6) Maximum size (including the electrical box)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

73

PMZ

Plenum with motorized dampers


for ducted fan coils

MULTIZONE PLENUM TO CONTROL THE AIR FLOW


TO BE COMBINED WITH FCX_I AND VED_I FAN COILS WITH
INVERTER MOTOR
PERFECT FOR RESIDENTIAL AND SERVICES SECTORS
APPLICATIONS
WIRELESS THERMOSTATS
Characteristics
The plenums with motorized dampers have
been designed for residential and service sectors applications. it allows to combine an
optimal environmental comfort with an assured energy saving.
More and more in modern systems one needs
to have a global climatization through ducted
systems. The accessory PMZ, thanks to the
electronic control of dampers, regulates the
room comfort, adjusting the air flow to actual
needs.
PMZ has been designed to be combined with

fan coils with inverter motor.


The structure is made of galvanized sheet ,
internally insulated with self-extinguishing
material. It is provided with a variable number from 2 to 6 circular attacks, equipped
with motorized dampers in two positions
(open/closed) depending on the combined
model.
The damper motor is controlled directly from
the wireless room thermostat. With the plenum it is provided a room thermostat for each

30C room air temperature


set 25C
damper
p n
n1
1 ope
open

motorized damper.
Regulation: the regulation system adjusts the
air flow provided by the fan coil according to
the number of open dampers.
The state of the damper (open/closed) is regulated by reaching the temperature set in each
room.
The control system is also able to control the
valves of on / off type, two or three-way valves for two or four pipe configuration.

30C room air temperature


set 25C
damper n3 open

25C room air temperature


set 25C
damper n2 closed

74

Compatibility Plenum with fancoils


PLENUM
2 DELIVERIES
PMZ22
PMZ32
PMZ42
PMZ22
PMZ32
PMZ42
-

FANCOIL

FCXI20/24P
FCXI30/34P
FCXI40/44P
FCXI50/54P
FCXI80/84P
VED030/040I
VED130/140I
VED230/240I
VED330/340I
VED530/540I
VED730/740I

PLENUM
3 DELIVERIES
PMZ33
PMZ43
PMZ43
PMZ83
PMZ33
PMZ43
PMZ83
-

PLENUM
4 DELIVERIES
PMZ44
PMZ44
PMZ84
PMZ44
PMZ84
PMZ504
-

PLENUM
5 DELIVERIES
PMZ505
PMZ705

PLENUM
6 DELIVERIES
PMZ706

Technical data
Mod. FCXI_P

Vel.

20

24

30

HEATING PERFORMANCE (2 PIPE CONFIGURATION)


Heating capacity (50C)
(1)
W
H
2100
2320
3160
H
258
298
380
Water ow rate
(1)
l/h
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70C)
(2)
W
H
1751
2826
Water ow rate
(2)
l/h
H
154
248
COOLING PERFORMANCE
Total cooling capacity
(3)
W
H
1500
1730
2210
H
258
298
380
Water ow rate
(3)
l/h
H
290
290
450
Air ow rate
m3/h
type
Fans
n
1
1
2
Max. high static pressure
Pa
H
50
50
56
Absorbed power
W
12
12
13
Absorbed power (plenum)
W

34

40

44

50

54

80

84

3550
482

4240
585

5250
765

4900
721

6100
855

7990
1276

10207
1479

3460
303

4223
370

6410
562

4190
721
720

4970
855
720

7420
1276
1140

8600
1479
1140

2
46
37

2
46
37

3
30
80

3
30
80

2800
482
450
2
56
13

3400
4450
585
765
600
600
centrifugal
2
2
53
53
17
17
5

Mod. VED_I

040
130
140
230
240
330
340
530
Vel. 030
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (50C)
(1)
W
H
2180 2340 3750 3940 4320 4750 6270 6550 10420
H
279
327
516
566
588
691
860
922 1335
Water ow rate
(1)
l/h
HEATING PERFORMANCE
with
with
with
with
(4 PIPE CONFIGURATION)
BV030
BV130
BV230
BV330
Heating capacity (70C)
(2)
W
H 2220
3780
4493
5888
H
196
331
394
515
Water ow rate
(2)
l/h
COOLING PERFORMANCE
Total cooling capacity
(3)
W
H
1624 1900 2997 3290 3420 4020 5000 5360 7760
Water ow rate
(3)
l/h
H
279
327
516
566
588
691
860
922 1335
Air ow rate
m3/h
H
285
277
433
420
590
570
805
775
1520
type
centrifugal
Fans
n
1
1
2
2
2
2
3
3
2
Max. high static pressure
Pa
H
61
61
60
60
64
63
66
64
58
Absorbed power
W
36
36
45
45
53
53
86
86
205
Absorbed power (plenum)
W
5

532

540

541

730

732

740

741

11820
1543

17280
2382

19150
2766

13540
1188

8850
776

22174
1945

14500
1272

7760
1335
1520

8970
1543
1500

2
56
185

2
56
205

8970 13850 13850 16080 16080


1543 2382 2382 2766 2766
1500 2410 2410 2350 2350
2
56
185

3
69
370

3
69
363

3
69
370

3
69
363

H max. speed;
2 pipes system configuration (EUROVENT)
(1) Room air temperature 20C b.s.; Inlet water temperare 50C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(2) Room air temperature 20C b.s.; Inlet water temperare 70C; T water 10C
Cooling performance (EUROVENT)
(3) Room air temperature 27C b.s./19C b.u.; Inlet water temperare 7C; 'T water 5C
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

WARNING
The brackets supplied as standard are higly
recommended to install fan coils from 20 to 54 size
with their plenums

200
200

A
D

200

Acessories Plenum
Height
Width
Depth
Delivery
Weight

A
B
C
D
n

kg

PMZ22
216
644
380
180
2
200
9

PMZ32
216
875
380
180
2
200
9

PMZ33
216
875
380
180
3
200
11

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

PMZ42
216
1095
380
180
2
200
10

PMZ43
216
1095
380
180
3
200
13

PMZ44
216
1095
380
180
4
200
14

PMZ83
216
1224
380
180
3
200
13

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

PMZ84 PMZ504 PMZ505 PMZ705 PMZ706


216
300
300
351
351
1224
1231
1231
1631
1631
380
380
380
380
380
180
180
180
180
180
4
4
5
5
6
200
200
200
200
200
14
22
24
32
35

75

Cod.: SPMZUY.01 / 1410

Ventilcassaforma

Template for recessed installation of


fancoils in the wall

CHF
CHU L

Ventilcassaforma has been designed to respond to the needs to rationalise spaces to suit modern interior
architecture.
Ventilcassaforma is a galvanised template that makes it possible to make a space to house fan coils in the
wall. The template will make masonry work easier during the construction of a niche where the fan coil will
be installed. When the work is finished, the fan coil will be completely hidden from view.
Ventilcassaforma is available in two versions with the same characteristics but designed to house fan coils
from two different series:
- CHU-L for fan coils in the Omnia UL-P series
- CHF for fan coils in the FCX-P , FCX-PV and FCXI-P series in 2 pipe systems, 2 pipe systems with resistance and with
4 pipe systems

Features
grey with rough glazed finish in order to Closure Panel: made of steel pre-treated
Available in two versions for combined
with base paint and no slots present.
hold the paint. The final colour can be
fan coils:
Easily removable for servicing and
chosen by the client.
CHU-L: Ventilcassaforma for the
cleaning the air filter.
OMNIA UL-P series. Available in four Closure Panel: Made of galvanised steel,
this is the box housing the fan coil. The Outer Frame: the perimeter of the box
sizes
has an outer frame made of pre-treated
box is recessed in the wall during buildCHF: Ventilcassaforma for FCX-P , FCX-PV
steel making it possible to cover the
ing work making the construction of a
and FCXI-P fan coils. Available in 5 sizes
perimeter part of the wall and hide any
niche where the fan coils will be
Compatible with VMF System
imperfections that overtime show possiinstalled much easier. Holes for fitting
Ventilcassaforma is made up of the folble crumbling on the edge of the plaster
the fan coil and preparing an electric
lowing parts to be assembled:
work.
plant with a socket and GEWISS fuse
- Recess box;
holder are already present on the back Deflector: manual, with which the flow
- Closure panel;
of air can be directed into the room. The
panel. The box can accommodate the
- Outer frame with deflector;
deflector is incorporated in the frame.
hydraulic system pipes and condensa- Cover bases, cross-members, covers.
tion drain pipes thanks to the presence
All parts are made of galvanised steel
of several easily-removable elements on
and treated with epoxy-polyester resinthe sides and base.
based thermo-hardening base paint in

76

Ventilcassaforma - Omnia UL combination


Ventilcassaforma CHU L + Omnia UL combination
CHU 12 L
CHU 17 L
Omnia UL 11 P
Omnia UL 16 P

Ventilcassaforma
Fan coil

Ventilcassaforma

CHF 17
FCX 17 P
FCX 17 PV

Fan coil

CHU 27 L
Omnia UL 26 P

CHU 37 L
Omnia UL 36 P

Ventilcassaforma CHF + FCX P - FCX PV - FCXI P combination


CHF 22
CHF 32
CHF 42
CHF 62
FCX 22 P
FCX 32 P - 36 P
FCX 42 P - 50 P - 56 P
FCX 62 P - 82 P - 102 P
FCX 22 PV
FCX 32 PV - 36 PV
FCX 42 PV - 50 PV - 56 PV FCX 62 PV - 82 PV - 102 PV
FCX 24 P
FCX 34 P
FCX 44 P - 54 P
FCX 64 P - 84 P
FCX 24 PV
FCX 34 PV
FCX 44 PV - 54 PV
FCX 64 PV - 84 PV
FCXI 20/24 P
FCXI 30/34/36 P
FCXI 40/44 P - 50/54/56 P
FCXI 80/84 P

The fan coils FCX-P , FCX-PV and FCXI-P can be inserted into 2 pipe systems, 2 pipe systems with resistance and 4 pipe systems

Dimensions (mm)
CHU
Height
Width
Depth

A
A1
B
B1
C

12 L
691
648
692
644
186

17 L
691
648
802
754
186

27 L
691
648
1032
984
186

37 L
691
648
1252
1204
186

A
A1
B
B1
C

17
728
684
732
684
240

22
728
684
842
794
240

32
728
684
1073
1025
240

42
728
684
1293
1245
240

A
A1
A2
A3
B
B1

12 L
724
634
70
494
713
633

17 L
724
634
70
494
823
743

27 L
724
634
70
494
1053
973

37 L
724
634
70
494
1273
1193

A
A1
A2
A3
A4
B
B1

17
760
680
93
493
94
753
673

22
760
680
93
493
94
863
783

32
760
680
93
493
94
1094
1014

42
760
680
93
493
94
1314
1234

CHF
Height
Width
Depth

62
833
789
1414
1366
240

Outer frame and closure panel

Height

Width

CHF

Height

Width

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

62
865
785
93
598
94
1435
1355

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

A4
Cod.: SVC2UY.08 / 1502

CHU

77

Control panels

Range of control panels for fan coils

WIDE RANGE OF CONTROL PANELS FOR AN EASY AND


COMPLETE CONTROL OF ALL FUNCTIONS OF THE FAN COIL

WMT21: 







K
,t

TPF: 

 






K
,t

PXAE: 

 






K
,t

PXAR: 

 




K
,t

78

Featres and standard eiment


t
 
 dKK
 d

 /

Accessries manageale (1)


te sstem
,

^t/
t^t/

2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 Z
 
 KK
 d
 /
 t
 

Accessries manageale (1)


te sstem
,




2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 t
 
 KK
 d
 /
 > 

Accessries manageale (1)


te sstem
,

t^t
^/d^/d

2 2 ies ith 4
ies resistance ies

Featres and standard eiment 


 t
 
 KK
 d
 /
 > 

Accessries manageale (1)


te sstem

^/d^/d
t^t


2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 Z
 
 KK
 d
 /
FMT21 : 


 
 

 
K
,t

Accessries manageale (1)


te sstem
,

^t
t^t
^/d
^/d


2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 &
 D
 KK
 d
 /
PXBI: 





K
,t

PXAI: 

 






K
,t

KTLM: 








Accessries manageale (1)


te sstem
,

^/d^/d

2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 &
 
 KK
 d
 /
 > 

Accessries manageale (1)


te sstem
,

^/d^/d

2 2 ies ith 4
ies resistance ies

Feate and tandad eiment


 
 
 KK
 d
 /&>
 
 

Aeie manageale (1)


te tem
,



2 2 ie ith 4
ie resistance ies

Featres and standard eiment


 &
 
 d
 /
PTI:  




Accessries manageale (1)
te sstem
,

^/d^/d

2 2 ies ith 4
ies resistance ies

EW

PTI2:
PTI2 


/EsZdZ






PX2: 




Accessries manageale (1)


te sstem
,



2 2 ies ith 4
ies resistance ies

PX2C6 : W

K
,t

Accessries manageale (1)


te sstem
,

^/d

2 2 ies ith 4
ies resistance ies

WMT05: 






Accessries manageale (1)
te sstem
^/d

Accessries manageale (1)


te sstem
,

^/d

2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 t
 D
 dKK
 d
 /

Featres and standard eiment


 t
 D
 d
 /

K
,t

2 2 ies ith 4
ies resistance* ies

Featres and standard eiment


 t
 s

Featres and standard eiment


 t
 s

PX: 







Accessries manageale (1)


te sstem
,



W


Featres and standard eiment


 
 
 KK
 
 
 
KTLP: 








Featres and standard eiment


 &
 
 KK
 d
 
 /


2 2 ies ith 4
ies resistance ies

WMT06: 








K
,t

Accessries manageale (1)


te sstem
,

^/d
Z

2 2 ies ith 4
ies resistance ies

Featres and standard eiment


 t
 
 KK

 d
FMT10:   






Accessries manageale (1)


2 2 ies ith 4


te sstem
ies resistance ies
,



K
Z

,t

WMT10: 






Accessries manageale (1)

te sstem


,

K
Z
,t
Aermec reserves the right to make all the modifications deemed
necessary for improving the product, including technical data.

2 2 ies ith 4
ies resistance ies

Code: SPCUY.09 / 1502

Featres and standard eiment


 t
 D
 KK
 d
 /

(1) r the names the accessries reer t the an cil technical sheets.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

79

NEW

VMF

Variable Multi Flow system


Range of components for the management of air conditioning,
heating and domestic hot water systems

Accessory module

VMF systems central interface

Zone interface

VMF-E4D
VMF-E4

VMF-VOC

VMF-E5N / VMF-E5B

VMF-CRP

*As awared by Chicago Athenaeum:


Museum of the Architecture and Design

Zone interface

Thermostat with serial communication

VMF-E0

VMF-E2
VMF-E2H

Domestic water panel

VMF-E1 / VMF-E18

VMF-SW / VMF-SW1

VMF-ACS

* Winner for the International design Award "Good Design 2010" for the "Electronics"

Features
VMF: Variable Multi Flow system.
Management and control system of hydronic
systems for the conditioning, heating and production of domestic hot water.
The VMF system allows complete control of
every component of a hydronic system both
locally and centrally and, communicating
between the various components of the
system, manages the performance without
ever neglecting the end user's request of
comfort, but reaching it as efficiently as possible with energy saving.
If you add the advantages deriving from such
an innovative control to the flexibility of a
hidronic system, you get a more efficient and
effective alternative to the variable refrigerant
flow systems (VRF).
The VMF system is extremely flexible, enough
to allow various control and manage steps,
expandable at different moments:

80

1) Control of a single fancoil.


2) Control of a microzone (one MASTER fancoil
and a maximum of 5 SLAVE fancoils).
3) Control of multi independent zones system
(one MASTER fancoil and a maximum of 5
SLAVE fancoils for each zone).
4) Control of a fancoil system, plus management
of the heat pump (if compatible with the VMF
system).
5) Control of a fancoil system, heat pump and
management of the domestic hot water
system (VMF-ACS).
6) Control of a fancoil system, heat pump,
domestic hot water production and additional
circulators (up to a maximum of 12 using
three additional VMF-CRP modules).
7) Control of a fancoil system, heat pump,
domestic hot water production, additional
circulators and management of heat recovery
units, maximum 3, (with the ability to handle
up to 3 VMF-VOC sensors) or a boiler.

The VMF system can operate and manage,


through a VMF-E5N / VMF-E5B panel, a
maximum of 64 zones consisting of a
MASTER fancoil and a maximum of 5 SLAVE
fancoils connected to each MASTER, for a
total of 384 fancoils.
Besides the central control supplied by
theVMF-E5N / VMF-E5B panel, the MASTER
fancoils must be provided with a local control interface; this interface can be mounted
on the fancoil (VMF-E2 / VMF-E2H) or be
mounted into a wall panel (VMF-E4).
Different functions can be controlled through
the VMF-E5N / VMF-E5B panel, including:
- Identify the different zones setting a name for
each one.
- Check and set the ON-OFF function and the
set temperature of each zone.
- Set and manage the set temperature of the
heat pump.
- Scheduling time slots.
Simple installation of the fancoil system
through the SELF-MONITORING function of
the MASTER fancoils.

System components
VMF-E0: thermostat accessory to fix on the
side of the fancoil, equipped with air and
water sensors as standard, controls 2 pipes, 4
pipes,
2 pipes + Plasmacluster, 2 pipes + UV lamps,
2 pipes + Electric heater systems. Equipped
with external contact to be used as low voltage remote ON-OFF. This thermostat can create a single fancoil zone through 2-wire serial
communication (1 master + 5 slaves maximum). The thermostat is fuse protected.
VMF-E1: like VMF-E0 with extra:
- Economy contact/presence sensor.
- Auxiliary water sensor for general control in
4-tube systems (with VMF-SW1 accessory).
- Serial RS485, protocol ModBus RTU, for centralised control.
- Possibility to insert expansion cards for future
development. The VMF-E1 accessory must
therefore be used in the Masters in the presence of multiple zones, or for communication with the chiller/heat pump.
VMF-E18: the same as the VMF-E1, but for
fancoils with inverter motors.
VMF-E2: this is the user interface on the
machine to match to the VMF-E0, VMF-E1
and E18 accessories for the series UL-S-FCXAS, FCX-U (sizes 62-64-82-84-102) FCX180U
FHX-U (sizes 62-82). Equipped with 2 selector switches, one for temperature and one for
speed control.
VMF-E2D: is the user interface (as above) on
the machine, to combine with accessories
VMF and VMF-E0-E1, dedicated to the series
DUALJET.
VMF-E2H: this is the User Interface (as above)
on the machine, to match to the VMF-E0, E1,
accessories dedicated to the HL series
VMF-E4: this is the wall mounted user interface, to match to the VMF-E0, VMF-E1 and
VMF-E18 accessories for the UL, HL, and
FCX series without on-board control.
Innovative design, extremely slim and inexpensive, allows control of functions via a
capacitive touch keypad with LCD display.
The environment can be adjusted with the

sensor on the panel (standard), or the sensor


of the fancoil which it is connected to, or by
their arithmetic mean. It also allows the activation o f t h e ai r p u ri f i er acces s o ry
(Plasmacluster / UV Lamp) and the electrical
heating element.
VMF-E4D:is the variant of the previous code,
but with frontal gray Pantone 425C (METAL)
VMF-E5B: white recessed panel, with backlit
graphic LCD and capacitive keyboard allows
the centralised command/control of a complete hydronic system consisting of Fancoils:
up to 64 fancoil zones consisting of a master
+ 5 slaves. Chiller/heat pump equipped with
Modu_Control, GR3 and pCO2/PCO controls (accessory required for RS 485 interface
with MODU-485A, AER485, AER485P2 /
AER485P1); circulators: up to 12 configurable
zone circulators; boiler: boiler consensus
management for hot water production; heat
recovery units: consents up to 3 per programmable recovery units based on the timing
and/or by measuring the air quality obtained
with the VMF-VOC accessory; domestic water
module: complete management of the domestic hot water production through the control
of: diverting/circulator valve, integrated resistor, accumulation temperature sensor, antilegionella circuit.
VMF-E5N: this is the variant of the previous
code, but with black plastic.
VMF-VOC : accessories for measuring air
quality (see related point in the description of
the VMF-E5B).
VMF-CRP: accessory module for the control
of the boilers, pumps and heat recovery units.
VMF-SIT3: Interface cards that allow you to connect

thermostats for the maximum control in the


cold range.
VMF-ACS3KM: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated single phase
3kW resistor command, Anti-legionella and
temperature sensor).
VMF-ACS3KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three-phase
3kW resistor command, Anti-legionella and
temperature sensor).
VMF-ACS6KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three phase
6kW resistor command, Anti-legionella and
temperature sensor).
VMF-ACS8KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three phase
8kW resistor command, Anti-legionella and
temperature sensor).
GLL_N: FCL_N grid units, equipped with thermostat card for serial communication with
the accessory functions equivalent and VMFE1 (this grid is a mandatory accessory for the
units FCL N);
GLLI_N: FCLI_N grid units, equipped with
thermostat card for serial communication
with the accessory functions equivalent and
VMF-E18, (this grid is a mandatory accessory
for the units FCLI N);

the thermostats VMF and VMF-E0-E1 to a fan motor


with high power (for selection see all the documentation of the thermostat and the fan coil).

VMF-SW: water sensor may be used in place


of the standard supplied with VMF-E0, VMFE1 and VMF-E18 thermostats for the installation upstream of the valve.
VMF-SW1: additional water sensor may be
used for 4-pipe systems with VMF-E1 and E18

Dimensions (mm)

A
[mm]
VMF-E5B / VMF-E5N 138
VMF-E4 / VMF-E4D 125
VMF-ACS
354
VMF-VOC
79

B
[mm]
110
80
544
81

C
[mm]
45
11
135
26

VMF-E5B / VMF-E5N

VMF-E4 / VMF-E4D

VMF-ACS

VMF-VOC

81

Selection 1 Compatibility of thermostats for serial communication and control interface for MASTER units
mod.
FCX
FCXI
HL
UL
FHX

Versions

Note

AS - UA - B
U
P - PPC - PO - PV
AS
U
P
S - SM
N
(1)
S
P
R
UV
(7)
UVP - UVPO

VEC
FCL
FCLI
VED
FCW
N
DUALJET

(8)
(8)

VMF-E0

VMF-E1

VMF-E18

VMF-E2

(7)

(7)

VMF-E2D

VMF-E2H

(7)
(7)

(7)

VMF-E4 /
VMF-E4D

GLL N

GLLI N

Selection 2 Compatibility of VMF-E5 7 VMF-E5B centralised control


mod.
FCX
FCXI
HL
UL
FHX
VEC
FCL
FCLI
VED
FCW
DUALJET

Versions
AS - U - UA - B
P - PPC - PO - PV
AS - U - P
S - SM
N
S
P
RI
UV - UVP - UVPO

Note
(2)
(2)
(2)
(2)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

VMF-E5N / VMF-E5B

Selection 3 Compatibility of heat pumps with electrical panel for domestic hot water management
mod.
ANL
ANLI
ANK
SRA
SRP-V1
NRL
NRC
WSH

Versions
H
Tutte
Tutte
Tutte
Tutte
H
H
Tutte

Note
(3) (4)
(4)
(4)
(4)
(4)
(3) (4)
(3) (4)
(4)

VMF-ACS3KM

VMF-ACS3KT

VMF-ACS6KT

VMF-ACS8KT

Selection 4 Compatibility of modules and additional sensors


mod.
VMF-E5N/ E5D
VED
RePuro
HRS

Versions
Tutte
Tutte

Note
(5) (6)
(9)
(5) (6)
(5) (6)

VMF-CRP

VMF-VOC
(6)

(6)
(6)

VMF-SIT3

Notes:
The versions with the accessories hanging MA or MP, can be treated equally to their respective versions FCX AS U FCX, FCX AU;
(1) This version includes the thermostat E0-VMF and VMF-E2H command interface already installed, these features make these models suitable for operation as a single
unit or function of the MASTER microzone plants (plants consist of a single zone, without centralized contol VMF-E5N / VMF-E5B);
(2) To be compatible with the centralized control of VMF-E5N / VMF-E5B, a fan must be set as MASTER of the area, therefore this must be equipped with the thermostat for
serial communications, or VMF VMF-E1-E18 and combined with a user interface ( VMF-E2, or VMF VMF-E2H-E4), or units FCL / FCLI equipped with a thermostat on the
grid GLL_N / GLLI_N, combined with a command interface VMF-E4 / VMF-E4D ;
(3) The heat pumps with integrated storage are not suitable for production of hot water;
(4) To know the maximum temperature of hot water production (plant and / or health) refer to the limits on the operating unit technical manual;
(5) All types of systems that provide centralized control of VMF-E5N / VMF-E5B, are compatible with the accessory modules (maximum 4) VMF-CRP, and each module can
function as a pump controller (4 for each accessory module) or boiler control and recovery (with ON / OFF control and management of 3 recovery boiler in addition to
3 accessories VMF-VOC);
(6) The compatibility of the probe VMF-VOC is only related to the presence of the accessory module in the system with VMF-CRP control function recovery;
(7) VMF-E2: Only for size FCX62U-64U-82U -84U-102U, FCXI80U, FHX62UV-82UV, for other sizes install VMF-E2D, side connections
(8) units must be included in boxes FCLI GLLI_N mandatory accessory grid, this grid is equipped with a card thermostat same rights as VMF-E18 models.
FCL cassette units must provide the mandatory accessory GLL_N grid, this grid is equipped with a card equivalent and thermostat models VMF-E1. To use one of these
drives as MASTER is necessary to provide the command interface VMF-E4;
(9) Accessory units required for the combination of VED with thermostats or VMF VMF-E0-E1. Using a VMF-SIT3 for each unit;
(*) Contact us

82

Example of system components


Selection 4:

A maximum number of 4 VMF-CRP modules


can be installed and each one can perform several tasks based on the type of setting:
- Control 4 pumps
- Control 3 heat recovery units and 3 VOC sensors (in this case the correct number of VMFVOC accessories must be purchased)
- Control a boiler
The only requirement to install VMF-CRP
modules is the presence of a VMF-E5 centralised
control

VMF-CRP
n1

n2

n3

n1

n2

n3

n4

VOC
VOC

n4

VOC

x3

VMF-ACS

The VMF-ACS accessory allows to control the different components needed to produce domestic hot
water; for detailed information on the types of systems
manageable by VMF-ACS, refer to technical documentation of the accessory

Selection 3:

Multicontrol

WARNING: in the case where the plant is provided


with accessory Multicontrol it will not be possible to
use the accessory VMF-ACS, since the production of
domestic hot water will be controled only through
the accessory Multicontrol.

VMF-CRP (Multicontrol)
n1

n2

n3

Selection 2:
WARNING:: Each chiller must be provided with the
appropriate communications accessory Modu-485A

VMF-E5

Chiller 1 (Multicontrol)

Chiller 4 (Multicontrol)

Chiller
RS-485
MODbus RS485
(MAX 1000m)

RS-485

RS-485
MODbus RS485 Multicontrol

Selection 1:
VMF-E4

Fancoil 1
A (MASTER)

ModBus TTL

MAX 30m (ModBus TTL)

Thermostat for serial connection VMF-E0 / VMF-E1 / VMF-E18

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Fancoil 64 (max)
A (MASTER)

Fancoil 1 (Slave)

Fancoil 1 (Slave)

Fancoil 2 (Slave)

Fancoil 2 (Slave)

Fancoil 3 (Slave)

Fancoil 3 (Slave)

Fancoil 4 (Slave)

Fancoil 4 (Slave)

Fancoil 5 (max) (Slave)

Fancoil 5 (max) (Slave)

Cod.: SVMFUY.08 / 1503

VMF-E4

Commands interface for MASTER unit VMF-E2 / VMF-E2H / VMF-E4

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293730
www.aermec.com

83

Climafon

Thermoconvectors
Vertical installation residential use

Flat grid, fixed


with aluminum fins

Aermec presents the brand new natural convection heating system in the CLIMAFON system.
CLIMAFON is born from long experience in the heat exchange field gained within the Giordano Riello International Group, a group in which
Aermec is the leading company.
CLIMAFON is a system terminal that works on the basis of natural convection: the air is heated through an exclusive finned exchange and is sent into
the room through a flue effect.

Features
Enhanced Comfort: CLIMAFON heats rooms Operation at full capacity achieved more
quickly and naturally because it basis its
quickly: CLIMAFON has much smaller water
operation on air moved by simple conveccontent. This enables it to be very fast in heattion. The use of CLIMAFON with low tempering times and permits it to be used only
ature heating systems (heat pump, condensawhere it is useful. The speed it takes
tion boiler, geothermal and solar...) ensures
CLIMAFON to reach full capacity operation
that the rooms are heated without drying the
has been checked by TV (world leader in
air. It causes a pleasant sensation of wellproduct assessment and verification).
being that helps to survive even the longest
and harshest winters in total relaxation.
Greater security: CLIMAFON's outer surface
reaches a top temperature of 43C, a value
Best quality of the air we breath: the air temthat is totally harmless for our body (the risk
perature of the air leaving CLIMAFON is such
of burning is nil). Its rounded form without
as not to allow the toasting of the powder in
sharp edges makes the room a safer environthe environment. The result is healthy, clean
ment especially for children.
air. In addition to our health, winners also
include the walls of our house (CLIMAFON Greater care to appearance: the soft flowing,
spells the end to the blackening of walls typimodern and elegant lines give CLIMAFON
cal of radiator systems).
greater appeal that enables it to be integrated
with all types of furnishing whether it is tradi Energy saving: the innovative finned exchangtional or modern.
er ensures high energy efficiency thanks the
possibility of effective use at low tempera- Easier and faster installation: CLIMAFON is
tures of the warm supply water.
much lighter than a radiator with the same

84

capacity; just one person is needed to handle


and install it quickly and easily on all types of
wall. CLIMAFON is fitted with an installation
template that means the unit can be assembled after the building work has been completed. Costly masonry work typical of radiator installation is avoided: just four blocks are
required for fixing CLIMAFON to the wall.

Versions
Available in four sizes Flat grid, fixed with aluminum fins.
The versions available are double (4 rows of pipes) or treble (6 rows of pipes). Water connections can be reversed during installation phase

Selection
By combining the various options, each model can be configured.
Code:
CLIMAFON
Size :
1, 2, 3, 4
Coil :
2 - Double
3 - Treble

Grille:
P - Flat grid, fixed with aluminum fins

Commercial code example: CLIMAFON 23P

Technical data
Mod. CLIMAFON
Heating capacity
Water flow rate
Water pressure drop
Water contents
Coil connections
Rows of pipes

W
l/h
kPa
l

12P
910
78
0,22
0,5
1/2
2

13P
1005
87
0,26
0,6
1/2
3

22P
1350
116
0,50
0,8
1/2
2

23P
1540
135
0,72
1,1
1/2
3

32P
1750
150
0,95
1,0
1/2
2

33P
2001
176
1,36
1,4
1/2
3

42P
2205
190
1,31
1,1
1/2
2

43P
2515
221
1,91
1,6
1/2
3

Heating (in accordance with UNI EN 442):


room air temperature 20 C; hot water temperature (in/out) 75/65C; 'T water 50 C

Dimensions (mm)
C

A
B
C

mm
mm
mm
kg

12P
630
600
140
12

13P
630
600
140
13

22P
630
800
140
15

23P
630
800
140
16

32P
630
1000
140
18

33P
630
1000
140
19

42P
630
1200
140
21

43P
630
1200
140
22

Cod.: SCFONUY.01 / 1501

Mod. CLIMAFON
Height
Width
Depth
Weight

All specifications are subject to change without prior notice.


Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

85

Climabox

Recessed wall-mounted convection heater

Climabox is the innovative built-in wall convection radiator for heating systems. It was created to meet the
needs for space rationalization according to modern architecture criteria for interiors and the current need
for energy saving.
Characteristics
Available in 3 sizes with double or triple battery.
Climabox consists of several parts to
be assembled:
1. Frame in galvanized and painted
p l a t e t h a t a l l ow s t h e h e a t
exchanger to be installed in the
wall.
2. Heat exchanger
, designed for maximum intensification of the natural convection
effect, constructed of copper piping and fining.
3. Closing panel
supplied, which allows the materials, desired look and colour of
the panel to be customized. Once
the work is complete, the heating
unit will be completely hidden
from view.
4. Head
Located on the upper horizontal
part of the panel, it is available
with a fixed metallic grille.

The closing panel and all of the visible


parts of the frame are treated so they can
be painted with the same paint as the
wall.
The Climabox convection heater
is the ideal terminal for heating
any room. Heat is supplied
instantly and uniformly distributed throughout the area.
It can be added to a heating system powered by a boiler, district
heating system or heat pump.
The possibility of easily removing the cover allows for thorough cleaning of the interior.
Ease of installation with reversable water attachments in the
installation phase. Full compliance with safety and injury prevention regulations

Unit choice
Any model can be configured by changing the available options.
Logo:
CLIMABOX
Size:
2, 3, 4

86

Battery:
2 - Double
3 - Triple
Grille:
Fixed grille

Head

closing
panel

Frame in
galvanized plate

Heat exchange
battery

Technical data
Mod.
Thermal power
Water flow rate
Water pressure drop
Water content
Battery connectors

CBX 22
1220
105
0,5
0,8

W
l/h
kPa
l
gas

CBX 23
1330
114
0,72
1,1

CBX 32
1610
138
0,95
1

CBX 33
1755
151
1,36
1,4

CBX 42
2005
172
1,31
1,1

CBX 43
2180
187
1,91
1,6

1/2" Female

Data in compliance with standard UNI EN 442


HEATING
Water input temperature
Water output temperature
room temperature

75 C
65 C
20 C (T0=50 C)

CHF
Height
Width
Exchanger width

A
A

mm
mm

22
155
884

23
155
884

32
155
1084

33
155
1084

42
155
1284

43
155
1284

mm

625

625

825

825

1025

1025

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Fax 044293577
www.aermec.com

Cod.: SCBXUY.01 / 1203

Dimensions (mm)

87

02. HEAT RECOVERY UNIT

Objective air quality and energy saving: Aermec offers a large range of air-air heat
recovery units for industrial and commercial systems and for Controlled Mechanical
Ventilation Systems for residential.
The heat recovery units, provided with appropriate accessories (heat exchange coils,
heat pump refrigerant circuit, etc.), actively participate in the air treatment providing an
important contribution to the air conditioning of the spaces served. The catalogued
range of nominal available air flow rates is from 100 to around 16.100 m/h.

RePuro

Heat recovery unit

high
efficiency

Aermec RePuroDistribution
This complete range of products for air distribution, which in association with the innovative series of units for heat and purication recovery RePuro, offers to designers, installators and end-users an efcient
solution, easy in the installation and confortable in all its cycle of life.
Examples of plenums for air distribution, which could be equipped of:
electric heater, germicidal lamp, water-exchanger.

PLS
with multi-way ange

PLS_M
with one-way ange

Characteristics
RePuro is an innovative counter-ow heat
recovery system which ensures the correct
renewal of air to indoor environments.
Through the use of up to 90% high efciency heat exchangers RePuro allows
the introduction of fresh air at a temperature close to that of the room concerned,
reducing energy costs that would be incurred in exchanging the air in traditional
ways or by mechanical ventilation alone.
PLASMACLUSTER ionising lter. Plasmacluster is capable of reducing the level of
pollutants, by decomposing the molecules that form them. The result is in the air:
you can nally breath clean, odour-free
ionised air.
Version
RePuro
standard
RePuro_R with electric pre-heater for
continuous operation in cold climates up
to -15C.
Installation
Wall installation and ceiling: (100170)

90

upright (250650)
Heat exchanger with hexagonal shape
to increase the surface area.
Heat exchanger easily removed from
the front for cleaning or replacement.
Casing in galvanised sheet steel with
internal insulation.
Standard lter on fresh air G4
Standard lter on extract air G2.
Filters can be removed for cleaning or
replacement.
All units are equipped with frost protection system for climates !-10C .
High efficiency of 90% and above
(UNI EN 308).
Free-cooling in mid-seasons through
the automatic by-pass function (RePuro
250-350-450-550-650).
By-pass no frost (RePuro 450-550-650)
Ionizer filter PLASMACLUSTER as standard.
Flow rate control 0-100% of nominal
air flow rate.

Direct drive centrifugal fans, with


"Brushless" EC high efficiency variable
speed electric motors (ERP2015).
Microprocessor controller with interface capability to the VMF System.
Monitoring of the units with remote
wired control panel (supplied as standard). Innovative design, extremely slim,
allows control of functions via a touch
keypad with LCD display.
The panel cable is 6 metres long supplied as standard.
Activation of the electric heater in the
RePuro_R version. Front in light grey
colour PANTONE COOL GRAY 1C.
Easy to wall mount with standard supplied
mounting plate, or oor mount with antivibration mounts AVM accessory.
Adaptable to existing systems.
Compact size.
Quiet operation.
The installation requires a condensate
drain system.

Accessories
AVM : Anti-vibration mounts
SSR : Bearing bracket (RePuro 250-350450-550-650)
FF7 : Air filters for fresh air with F7 efficiency
KSAE : External air temperature sensor
PLS : Plenum with acoustic lining equipped
with multi-way flange to ensure a uniform distribution in all treated areas.
The plenum is configured with:
- PLS_E electric heater
- PLS_L germicidal lamp
- PLS_W water coil (requires accessory valve)
PLSM : Plenum with acoustic lining equipped
with one-way flange.
IThe plenum is configured with:
- PLSM_E electric heater
- PLSM_L germicidal lamp
- PLSM_W Plenum with acoustic lining
equipped with one-way flange)
VCH : Kit consisting of powered 3-way valve,
copper couplings and pipes. Combined with
Mod. RePuro
AVM
SSR
FF7

KSAE
Delivery plenum with multiway flange
PLS350
PLS350W
PLS350E
PLS350L
PLS350WE
PLS350WL
PLS350WLE
PLS350LE
PLS650
PLS650W
PLS650E
PLS650L
PLS650WE
PLS650WL
PLS650WLE
PLS650LE
Delivery plenum with one-way flange
PLSM350
PLSM350W
PLSM350E
PLSM350L
PLSM350WE
PLSM350WL
PLSM350WLE
PLSM350LE
PLSM650
PLSM650W
PLSM650E
PLSM650L
PLSM650WE
PLSM650WL
PLSM650WLE
PLSM650LE
Kit for plenum
VCH
VCHR
VCHD
BC10
BC20
VMF-system
VMF-CRP
VMF-VOC
VMF-E5N
VMF-E5B

respectively MODU-485A, AER485,


AER485P2 / AER485P1),
- Circulators: maximum of 12 configurable
zone circulators;
- Boiler: boiler enable for hot water production;
- Domestic hot water module: complete
management of the production of domestic
hot water through the control of diverting
valve/circulator, immersion heater, storage
tank temperature sensor, anti-legionella cycle.
VMF-E5N : Variant of the VMF-E5B panel
but with black coloured plastic.
VMF-VOC : Accessory for measuring air
quality (see relevant point in the description
of the VMF-E5B panel).
VMF-CRP : Accessory module for the control
of the boilers, pumps and heat recovery units.

Vers.

100

170

250

350

450

550

650

All
All
All
All

170

170

350

350

650

650

650

(1)

(1)
(1)
(1)

(1)

(1)
(1)
(1)

(1)(2)

(1)(2)
(1)(2)
(1)(2)

(1)(2)

(1)(2)
(1)(2)
(1)(2)

(3)
(3)
(3)

the accessory PLS/PLSM in the conguration


with the water heat exchanger. In cooling
recovery it requires an accessory tray BC.
VCHR : such as VCH, but with isolation as.
VCHD : such as VCH, but with 2-way valve
instead of 3-way one.
BC :Auxiliary condensate drip tray.
BC10 for vertical installation.
BC20 for horizontal installation.
VMF-E5B : White recessed panel, with backlit graphic LCD and touch keypad allowing
the centralised command/control of a complete hydronic system consisting of:
- Heat recovery units: up to 3 outputs for heat
recovery units programmed according to
time-clocks and/or by measuring the air quality obtained with the VMF-VOC accessory;
- Fan coil units: up to 64 fan coil zones comprising 1 master + maximum 5 slaves;
- Chiller/heat pump unit equipped with controls Modu_Control, GR3 and pCO 2 /
pCO3 (required accessory RS 485 interface

(1) Combination with three-way valve kit required.


(2) If you intend to use all the after-heating coil system, or in all the situations in which the air temperature inside the pipe could provoke
condensation on external surfaces of pipe, it is mandatory to isolate adequately the installation components.
(3) in the cold-functioning they require the accessory BC10 o 20

91

Technical data
Mod.
Nominal air ow rate
Available static pressure
Winter recovery efciency
Recovered heating capacity
Winter recovery efciency
Recovered heating capacity
Summer recovery efciency
Recovered cooling capacity

RePuro
m3/h
Pa
%
W
(1) %
(1) W
%
W

100
100
85
94,4
957
90,6
601
90,6
180

170
170
20
91,2
1573
85,3
963
85,3
289

250
250
195
91,9
2329
86,3
1433
86,4
430

350
350
133
89,4
3171
82,2
1910
82,2
573

450
450
100
90,3
4118
83,7
2500
83,7
750

550
550
120
88,6
4940
81
2957
81
887

650
650
70
87
5734
78,4
3386
78,5
1015

Nominal air ow rate


Available static pressure
Winter recovery efciency
Recovered heating capacity
Winter recovery efciency
Recovered heating capacity
Summer recovery efciency
Recovered cooling capacity

(2) m3/h
Pa
%
W
%
W
%
W

75
135
95,7
728
92,7
462
92,7
138

125
110
93,2
1181
88,6
735
88,6
220

150
331
94,8
1441
91,1
908
91,2
272

200
376
93,3
1891
88,6
1177
88,7
353

300
210
93
2830
88,2
1758
88,3
527

350
300
92,1
3267
86,6
2014
86,7
604

450
270
90,3
4118
83,7
2500
83,7
750

Nominal air ow rate


Available static pressure
Winter recovery efciency
Recovered heating capacity
Winter recovery efciency
Recovered heating capacity
Summer recovery efciency
Recovered cooling capacity

(2) m3/h
Pa
%
W
(1) %
(1) W
%
W

50
185
97
492
95
315
95
95

75
210
95,7
728
92,7
462
92,7
138

75
426
97,2
739
95,3
475
95,3
142

100
526
96,4
977
93,9
623
93,9
187

150
310
96,2
1463
93,6
932
93,6
280

175
430
95,7
1697
92,7
1077
92,7
323

200
485
95,1
1928
91,7
1218
91,7
365

GENERAL DATA
Maximum power input
Power supply

W
45
65
160
180
220
280
360
V/ph/Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz

Winter recovery
Exhaust air temperature 20C b.s. 50% u.r.; Fresh air temperature -10Cb.s. 80%u.r.
(1) Exhaust air temperature 25C b.s. 27% u.r.; Fresh air temperature 5Cb.s. 50%u.r. (UNI EN308)
Summer recovery
Exhaust air temperature 26C b.s. 50% u.r.; Fresh air temperature 32Cb.s. 50%u.r.
(2) capacities obtained with air flows different from nominal ones.

Dimensions (mm)
Extract air
VMF-E4 RePuro
Fresh air

6m

180
150

33

160

77
150

750
575

150

427

72*
800

655

242

RePuro 100 - RePuro 170

Mod. RePuro
Weight

92

(kg)

520

72*

RePuro 250 - RePuro 350


* = with AVM accessory
Vers.
tutte

100
25

170
25

250
48

350
48

800

530

RePuro 450 - RePuro 550 - RePuro 650

450
55

550
55

650
55

Aermec RePuroDistribution
This complete range of products for air distribution, which in association with the innovative series of units for heat and purication
recovery RePuro, offers to designers, installators and end-users an efcient solution, easy in the installation and confortable in all
its cycle of life.

3
4

6
6

EASY "PLUG & PLAY" INSTALLATION


LOW DUCT HEIGHT FOR IN-WALL AND SCREEDFLOOR APPLICATION
ANTI-STATIC AND ANTI-BACTERIAL PROPERTIES
LONG-TERM ENERGY EFFICIENT BY MECHANICAL
CONNECTIONS
THE DUCT SEMI-OVAL IS CERTIFIED TV
Please note:
The picture shows as and indication only an example of an installation with semi-oval, semi-rigid antibacteric ducts, composed by:
1
2
3
4
5
6

heat recovery unit RePuro


Duct with external air intake/expulsion
Interconnection between RePuro and distribution box
Distribution box
Air distribution with semi-oval semi-rigid antibacterial ducts.
Terminals with nozzles and design grilles
The Aermec range in addition to point n. 5 5 , provides two other air distribution system:
- air distribution with round semi-rigid ducts;
- air distribution with rigid rectangular ducts.

93

RePuroDistribution
SINGLE SYSTEM OF AIR INLET AND EXHAUST CONNECTED TO REPURO
1
2
3

Heat recovery unit RePuro


Ducts with external air intake/expulsion
Interconnection between RePuro and distribution plenum

Some examples
of the components

n in to
package

100

170

COMPONENTS FOR EXTERNAL AIR INTAKE/EXPULSION SYSTEM


TV-150
vertical black roof terminal DN150
1

T25-150
Underlay for pitched roofs 5-25 DN150
1

T45-150
Underlay for pitched roofs 25-45 DN150
1

T55-150
Underlay for pitched roofs 35-55 DN150
1

TP-150
Rose window deal for at roofs DN150
1

TAP-150B
Suction wall terminal white DN150
1

TAP-150N
Suction wall terminal black DN150
1

CCI-150
Insulated duct L=2000mm - DN150
1

C90-150
90 insulated curve DN150
4

C45-150
45 insulated curve DN150
4

C30-150
30 insulated curve DN150
4

C15-150
15 insulated curve DN150
4

GC-150
Clip locking collar for ducts DN150
16

CLF-150
Locking collar joint - duct DN150
16

SC-150
Silencer L=1000mm - DN150
1

TV-180
Terminal with vertical black roof DN180
1
T45-180
Underlay for pitched roofs 25-45 DN180
1
TP-180
Rose window deal for at roofs DN180
1
TAP-180B
Suction wall terminal white DN180
1
TAP-180N
Suction wall terminal black DN180
1
CCI-180
insulated duct L=2000mm DN180
1
C90-180
90 insulated curve DN180
4
C45-180
45 insulated curve DN180
4
C30-180
30 insulated curve DN180
4
C15-180
15 insulated curve DN180
4
GC-180
Locking collar joint DN180
16
CLF-180
Collare di ssaggio giunto - canale DN180
16
SC-180
Silencer L=1500mm - DN180
1
COMPONENTS OF INTERCONNECTIONS BETWEEN RePuro UNITS, PLENUM AND SILENCERS
CCI-150
Insulated duct L=2250mm DN150
1

C90-150
90 insulated curve DN150
4

C45-150
45 insulated curve DN150
4

C30-150
30 insulated curve DN150
4

C15-150
15 insulated curve DN150
4

GC-150
Duct clip joints DN150
16

CLF-150
Locking collar joint - duct DN150
16

SC-150
Silencer L=1000mm - DN150
1

CCI-180
Insulated duct L=2250mm DN180
1
C90-180
90 insulated curve DN180
4
C45-180
45 insulated curve DN180
4
C30-180
30 insulated curve DN180
4
C15-180
15 insulated curve DN180
4
GC-180
Duct clip joint DN180
16
CLF-180
Locking collar joint - duct DN180
16
SC-180
Silenziatore L=1500mm - DN180
1
-

250
250R

RePuro
350
350R

450
450R

550
550R

650
650R

Please note: For further informations on the typologies of installations and of accessories, please referr to the dedicated documentation available
on Aermec website www.aermec.com.

94

RePuroDistribution
DISTRIBUTION SYSTEM WITH SEMI-OVAL SEMI-RIGID
ANTIBACTERIC DUCTS

Aermec, offers the possibility of any post-treatment, of mono-multi ange delivery plenum
(PLSM/PLS) with different combinable accessories :
- Electric heater
- Germicidal lamp
- Water exchanger

PLSM
5

(PLSM/PLS) always has to be installed before


distribution box.

4
5
6

Distribution box
Semi-oval semi-rigid antibacteric ducts
Recovery terminals with nozzles or grilles of design

n in to
package

100

170

RePuro
250 350 450 550 650
250R 350R 450R 550R 650R

COMPONENTS OF DISTRIBUTION SEMI-OVAL SEMI-RIGID BETWEEN PLENUM AND ELEMENTS FOR AIR DIFFUSION AND RECOVERY .
BDX6-150

Distribution box 6 nozzles with deadening DN150

BDSX10-150

Distribution box 10 noozles with deadening and silencer bafers DN150

BDX12-150

Distribution box 12 nozzles with deadening DN150

BDSX15-180

Distribution box 15 nozzles with deadening and silencer bafers DN180

CO30

Semi-oval semi-rigid antibacteric duct L=30

CO50

Semi-oval semi-rigid antibacteric duct L=50m

RDP

Flow regulator for semi-oval semi-rigid antibacteric ducts

10

SMC

Mounting bracket for semi-oval semi-rigid antibacteric ducts

10

ADT

Sealing ring for semi-oval semi-rigid antibacteric ducts

CVO

Vertical curve for semi-oval duct

COO

Horizontal curve for semi-oval semi-rigid antibacteric ducts

TO

Cap for semi-oval semi-rigid antibacteric ducts

GCO

Joint for semi-oval semi-rigid antibacteric ducts

GOO90

AD125X2

90 curve to attach semi-oval semi-rigid antibacteric ducts with round


semi-rigid ducts.
Adaptor for nozzle(x 2) - DN125

CGP

Collector for at grille (x 2) - (309x86)

ADG

Adaptor for grille (140x140)

TERMINALS FOR AIR INTAKE AND INPUT FROM ROOMS SUGGESTED FOR RESIDENTIAL USE
Some examples

Please note: For further informations on the typologies of installations and of accessories,
please referr to the dedicated documentation available on Aermec website www.aermec.com
GRM

BIM125

GRRM

GRM

Painted steel grille RAL9010

GRAI

Stainless steel grille

BES-125

Extraction nozzle DN 125

BIM-125

Input nozzle DN125

TERMINALS FOR AIR INTAKE AND INPUT FROM ROOMS SUGGESTED FOR COMMERCIAL USE
GRQM

Square grille with xed aluminium ns

GRRM

Rectangular grille with xed aluminium ns

GRQB

Square grille with horizontal and vertical swinging aluminium ns

GRRB

Rectangular grille with horizontal and vertical swinging aluminium ns

GRQL

Square grille with vertical swinging aluminium ns

GRRL

Griglia rettangolare con alette verticali orientabili alluminio

95

RePuroDistribution
DISTRIBUTION SYSTEM WITH ROUND SEMI-RIGID DUCTS
Aermec offers the opportunity for an eventual
after-treatment of intake plenum mono-multi
ange (PLSM/PLS) with different combinable
accessories:
- Electric heater
- Germicidal lamp
- Water exchanger

PLSM

(PLSM/PLS) va installato sempre


prima del box di distribuzione

6
4
5
6

Distribution box
Semi-rigid round ducts
Recovery terminals with nozzles and design grilles

n in to
packapackage
ge

170

250
250R

RePuro
350
450
350R 450R

550
550R

650
650R

COMPONENTS FOR DISTRIBUTION ROUND SEMI-RIGID BETWEEN PLENUM AND ELEMENTS FOR AIR DIFFUSION AND RECOVERY
BDX6T-150
BDX10T-150
BDSX10T-150
BDSX15T-180

Deadening Distribution box with 6 nozzles 75 (internal ) DN150


Distribution box 10 nozzles with deadening and silenced septa
75 (internal) - DN150
Distribution box 10 nozzles with deadening and silenced septa
75 (internal) - DN150
Distribution box 15 nozzles with deadening and silenced septa
75 (internal) - DN180

CT50

Round duct 63mm (internal) / 75 mm (external) L=50m

CT50AB

Round duct 63mm (internal) / 75 mm (external) L=50m


Antistatic and antibacteric

RDPT

Flow regulator for round ducts

10

AD125X2T

Adaptor for nozzles 2x75mm - DN125

ADTT

Sealing ring for round ducts 75mm

10

TCT

Cap for round ducts 75mm

GCT

Joint for round ducts 75mm

ADGR2T

Adatptor for rectangular grille 2x75mm (external)

ADGQ1T

Adaptor for rectangular grille 1x75mm (external)

TERMINAL FOR AIR INTAKE AND INPUT FROM ROOMS SUGGESTED FOR RESIDENTIAL USE
Some examples

Please note: For further informations on the typologies of installations and of accessories,
please referr to the dedicated documentation available on Aermec website www.aermec.com
GRM

BIM125

GRRM

GRM

Metal grille RAL9010

GRAI

Steinless steel grille

BES-125

Extraction nozzle DN 125

BIM-125

Input nozzle DN125

TERMINAL FOR AIR INTAKE AND INPUT FROM ROOMS SUGGESTED FOR COMMERCIAL USE
GRQM

Square grille with xed aluminium ns

GRRM

Rectangular grille with xed aluminium ns

GRQB
GRRB

Square grille with horizontal and vertical swinging aluminium


ns
Rectangular griille with horizontal and vertical swinging aluminium ns.

GRQL

Square grille with vertical swinging aluminium ns

GRRL

Rectangular grille with vertical swinging aluminium ns

96

RePuroDistribution
DISTRIBUTION SYSTEM WITH RECTANGULAR RIGID DUCTS

In this system Plenum


PLS can be used also as
a simple distribution box
without any accessory for
post-treatment.

PLS350

PLS350

6
4
5
6

distribution Plenum PLS


Rectangular rigid ducts
Recovery terminals with nozzles and design grilles

n in to
package

RePuro
100

170

250
250R

350
350R

450
450R

550
550R

650
650R

COMPONENTS FOR RECTANGULAR RIGID DISTRIBUTION WITHIN PLENUM AND ELEMENTS FOR AIR DIFFUSION AND INTAKE
CPR

Rectangular at duct 55x110x2000mm

GRT

Rectangular joint 55x110mm

CRT

Rectangular terminal frame 55x110mm

ARC

Rectangular/Circular adaptor 55x110mm/ 100

GRCV90

Vertical crank 90
Rectangular Circular Adaptor55x110mm

GRO45

Crank 45 Rectangular Horizontal 55x110mm

GRO90

Crank 90 Rectangular Horizontal 55x110mm

GRV90

Crank 90 rectangular vertical 55x110mm

TR

Rectangular terminal cap

RMC100

Multi-cone reducer 100 - 80

RMC125

Multi-cone reducer 125 - 100

RTR

Rectangular T joint 55x110mm

CR

Rectangular collar 55x110mm

10

MFR

Rectangular exible sleeve 55x110x500mm

CT50

Round duct 63mm (internal) / 75 mm (external) L=50m

CT50AB

Round duct 63mm (internal) / 75 mm (external) L=50m


Antistatic and antibacteric

RDPT

Flow regulator for round ducts

10

ADTT

Sealing ring for round ducts 75mm

10

CPVC

Glue for PVC

NAL

Aluminium tape 50x0,3mm Lenght= 50m

ACCESSORIES FOR AIR DIFFUSION AND RECOVERY


Some examples

BCI

GRIR

Please note: For further informations on the typologies of installations and of accessories,
please referr to the dedicated documentation available on Aermec website www.aermec.com

GRIR

Rectangular template grille 55x110mm

GRIC

Circular template grille 100mm

10

BCI

Circular template nozzle with net 100mm

10

BFR

Self-adjusting template nozzle 100mm

BA30

Self-adjusting nozzle 30m/h 125mm

BA60

Self-adjusting nozzle 60m/h 125mm

Please note: For further informations on the typologies of installations and of accessories, please referr to the dedicated documentation available
on Aermec website www.aermec.com.
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

97

Cod.: SREPUY.08 /1501

BA

TRS

Heat recovery unit with enthalpic heat exchanger

TRSCPR

TRSCP

These units allow the extraction of a fixed amount of air from the room to be replaced with fresh air.
Static type heat recovery unit with high efficiency in counter-flow, consisting of flat sheets of special paper. This
particular material allows a "total" type heat exchange as both sensible heat and the latent heat (moisture) are recovered
with average efficiency of 75% on the temperature (depending on the models) and 60% on the enthalpy, with high
performance even in summer. The air flows are kept separated by a suitable sealing.

Features
Available in 6 sizes for horizontal installation
High efficiency superior to that obtained from
the units with only the recovery of sensible
heat
Free-cooling during spring and autumn
thanks to automatic by-pass function
Double suction centrifugal fans, directly
coupled to high-efficiency "Brushless DC"
electric motors, equipped with adjustable
speed using an electronic regulator to vary
the flow rate

Control of the units between the control


panel with LCD display (TRSCP accessory) or
Kit with wired control panel with LCD display
and remote control (TRSCPR accessory)
Enthalpic heat recovery unit with hexagonal
shape to increase the exchange surface
Enthalpic heat recovery unit can be easily
removed laterally for cleaning or replacement
Self-supporting galvanized steel metal panels
with insulation.
Compact size for installation in suspended
ceilings

Inlet air filter, both on the external air inlet


side and on the fresh air from the room side
Synthetic filter on the internal air inlet with
class G4
Filters laterally removable for cleaning or
replacement
Quiet operation
The installation does not require the
condensate discharge system

Accessories
It is mandatory to use one of the two accessories as they are essential to the operation of the units:
TRSCP: Wired control panel with LCD display TRSCPR: Remote control and wired control
for controlling the On-Off functions, speed
panel with LCD display for control of the
selection, weekly programmable timer,
On-Off functions, speed selection, weekly
automatic Free-Cooling function. IR receiver
programmable timer, automatic Free-Cooling
for operation coupled to the IR remote
function. IR receiver for operation coupled to
control accessory.
the IR remote control accessory.
Recessed wall mounting in "module 502"
Recessed wall mounting in "module 502"
electrical boxes.
electrical boxes.
Compatibility of accessories

TRS15

TRS25

TRS35

TRS50

TRS80

TRS100

TRSCP

TRSCPR

98

Technical data
HEAT RECOVERY UNIT
Winter operation

Efciency

TRS15

TRS25

TRS35

TRS50

TRS80

TRS100

Temperature
Enthalpy

%
%

77
62

76
62

77
63

76.5
62.3

73
59

73.5
59.5

Power recovered at
full speed

kW

1.3

2.2

3.1

4.3

6.5

8.2

Temperature
Enthalpy
Power recovered at
full speed

%
%

63
60

62
60

63
61

62.5
60

59
57

59.5
57.5

kW

0.5

0.8

1.2

1.7

2.5

3.2

Maximum
Average
Minimum
Maximum
Average
Minimum
Maximum
Average
Minimum
Maximum
Average
Minimum

m3/h
m3/h
m3/h
Pa
Pa
Pa
W
W
W
dB(A)
dB(A)
dB(A)
V/ph/Hz

150
150
100
85
70
50
80
55
30
26
24
22

250
250
160
85
65
30
90
60
35
27
26
22

350
350
270
90
60
30
120
80
45
31
29
25

500
500
360
100
60
30
135
110
60
33
31
27

800
800
625
150
100
40
300
190
110
38
36
32

1000
780
650
150
100
40
310
200
125
39
37
33

Summer operation
Efciency

Nominal air ow rate

Useful static pressure (*)

Input power

Sound pressure level


Power supply

230/1/50

Performance values refer to the following conditions:


(*) Values referring to the nominal ow net of heat recovery unit and lter
pressure drops
Sound pressure level (A-weighted) measured in free eld at a distance of
1.5 metres from the inlet of the unit. The operation noise level generally
differs from the values shown, depending on operating conditions,
reected noise and surrounding noise.

- external air: -5C W.B.; R.H. 80%


- room air: 20C W.B.; R.H. 50%
Nominal conditions in summer operation:
- external air: 32C W.B.; R.H. 50%
- room air: 26C W.B.; R.H. 50%

Nominal conditions in winter operation:

Dimensions (mm)

Inspection panel

D
A2
A
A1

Fresh air

TRS15
TRS25
TRS35
TRS50
TRS80
TRS100

Remote control

A1

A2

B1

B2

885
885
885
970
1322
1322

815
815
815
910
1252
1252

1074
1074
1074
1130
1486
1486

666
666
806
997
882
1132

720
720
860
1053
936
1186

779
779
919
1112
994
1244

272
272
272
312
390
390

342
342
482
728
431
681

110
110
110
38
169
169

100
150
150
200
250
250

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

Weight
(kg)
27
27
32
42
63
76

99

Code: STRSUY.00 / 1203

B1

Outlet air

B2

Wired panel

UR

Heat recovery unit

These units allow you to extract a certain amount of exhaust air from the room and supply an equivalent quantity of fresh air.
A crossflow aluminium plate exchanger assures an efficient heat exchange between exhaust and fresh air: therefore the fresh air is pre-heated or precooled according to the seasons.
The supply air is filtered before entering the heat recovery exchanger that is protected with a synthetic filter also at the exhaust air side.
The supply air can optionally be re-heated with a hot water coil or with an electric coil.

Features
7 sizes are available:
UR: standard version
UR W: same as standard version and
equipped with water heating coil with copper
tubes and 3-row aluminium louvers. Not to
be used with chilled water.
UR E: same as standard versions and
equipped with electric heating coil with aluminium louvers and double safety thermostat.
Double suction centrifugal fans coupled
directly to the electric motors, equipped with
adjustable speeds via an electronic control to

vary the flow rate.


cleaning or replacement.
G3 class synthetic filter on the air outlet.
Two versions available for horizontal and ver Aluminium plate reheater housed in the contical installation (it is not possible to install
densate tray that is easily removed from the
the cooling coil accessories and silencers for
bottom.
the vertical installation).
G3 class synthetic filter on the fresh air intake Electronic Regulator with Slave Application
Self-bearing panels made of galvanized sheet
allowing continuous variation of rotation
metal with injected polyurethane insulation
speed and air flow rate.
and thickness 20 mm.
Galvanized condensate tray.
Fans can be inspected from the bottom.
Filters can be removed from the bottom for

Accessories
BF: Water cooling coil.
MPW: Module with 4-row water coolingincluded.
FGC: Circular flanges.
coil and 1-row water post-heating coil.
SE: Free-Cooling control dampers.
G4: High-efficiency filters on the fresh air MPX: Module with 4-row water cooling SU: Silencers.
intake in class G4.
coil and electric post-heating coil with reinforced louvered coils. Safety thermostat

100

Compatibility of Accessories
Horizontal installation:
BF
FGC
G4
MPW
MPX
SE
SU

UR 35
BF35
FGC1
G435
MPW35
MPX35
SE1
SU1

UR 55
BF55
FGC1
G455
MPW55
MPX55
SE1
SU1

UR 75
BF75
FGC1
G475
MPW75
MPX75
SE2
SU2

UR 100
BF100
FGC2
G4100
MPW100
MPX100
SE3
SU3

UR 150
BF150
FGC2
G4150
MPW150
MPX150
SE3
SU3

UR 210
BF210
G4210
MPW210
MPX210
SE4
SU4

UR 330
BF33
G4330
MPW330
MPX330
SE5
SU5

UR 35
FGC1
G435
SE1

UR 55
FGC1
G455
SE1

UR 75
FGC1
G475
SE2

UR 100
FGC2
G4100
SE3

UR 150
FGC2
G4150
SE3

UR 210
G4210
SE4

UR 330
G4330
SE5

Vertical installation:
FGC
G4
SE

Technical data
Mod.
Air ow rate
Static pressure (max speed)
Recovery unit:
Heating capacity recovered
Cooling capacity recovered
Recovery unit efciency
Internal water heating coil heating capacity
Internal electric heating coil heating capacity
Cooling coil cooling capacity (BF)
Water post-heating coil heating capacity (MPW)
Electric post-heating coil heating capacity (MPX)
Sound pressure level
Total input power
Filters:
EN779 Classication
Efciency
Power supply

(1) m3/h
(1) Pa
(2)
(3)
(2)
(4)
(5)
(6)
(7)
(8)

kW
kW
%
kW
kW
kW
kW
kW
dB(A)
kW

UR 35
350
125

UR 55
550
280

UR 75
700
173

1.5
0.4
52.1
4.1
2.5
3.4
1.5
1.5
44
0.30

2.5
0.7
55
6.7
2.5
4.9
2.4
2
44
0.58

3.2
0.9
54.3
8.2
4.7
6.1
3.2
2.8
44
0.58

G3
80

G3
80

G3
80

UR 100 UR 150 UR 210 UR 330


1000
1500
2100
3300
170
160
140
150
4.6
1.3
54.4
13
6
10.2
4.8
4
48
1.84

6.7
1.9
53.1
18.7
10
13.8
5.7
6
47
1.84

G3
G3
80
80
230V/1/50Hz

9.3
2.6
52.7
25.9
15
18.5
7.4
8
52
1.84

14.3
4.3
52
36.6
25
28
10.2
13
55
3.68

G3
80

G3
80

(1) At maximum fan speed


(2) Fresh air flow rate equal to the exhaust air flow rate; Incoming ambient air temperature -5C, 80% UR; Room temperature 20C, 50% UR.
(3) Fresh air flow rate equal to the exhaust air flow rate; Incoming ambient air temperature 34C, 50% UR; Room temperature 26C, 50% UR.
(4) Air temperature 8C; Water temperature (in/out) 70C/60C
(5) 400V/3/50Hz
(6) Air temperature 30C 60 UR; Water temperature (in/out) 7C/12C
(7) Air temperature 17C; Water temperature (in/out) 70C/60C
(8) 400V/3/50Hz
Sound pressure level referring to a distance of 1.5m, directivity factor=2, fan at max speed, supply and exhaust channelled for at least 2m

Dimensions (mm)

Mod. UR
Height
Width
Depth
Weight (kg)

A
B
C
UR Std
UR E
UR W

35
1090
900
300
61
62
62

55
1090
900
300
65
66
66

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

75
1190
1000
330
74
75
75

100
1500
1250
390
115
117
117

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

150
1500
1250
390
130
133
133

210
1750
1400
390
170
174
174

330
2500
1750
390
280
286
286

101

RPF

High performance heat recovery unit


with cross-current recuperator.
Nominal air flow from 790 to 4250 m3/h.

CROSS-CURRENT HEAT RECOVERY


WITH PERFORMANCES SUPERIOR THAN 90%
PLUG FANS COUPLED WITH EC BRUSHLESS MOTORS
FOR ENERGY COSTS REDUCTION
Features
Heat recovery units RPF have been designed
for commercial applications and permits to
combine an excellent ambient comfort with a
sure energy saving.
Always more in the modern plant design
there is the demand to have a Controlled
Mechanical Ventilation, which implies the
expulsion of conditioned air, determining a
higher consumption of energy and consequently an increase of prices.
The units RPF thanks to the cross-current
heat recuperator permit to save more than
90% of energy which otherwise would be
lost with expelled stuffy air.

density 45 kg/m3. The expandent of the polyurethane foam is based on water permitting
to reach GWP=0 (Global Warming
Potential).
The casing is in fire reaction class M1
according to the French regulation NF P
92-512:1986.
Removable panels are also foreseen to
access to internal components, equipped
with safety locks, condensate drain and internal modulating rolling shutter of motorized
and controlled bypass for free-cooling.

contamination of air flows, because the plates


are properly sealed.
Its performance is not inferior to 90%
(EN308) in function to the external conditions: Air of intake: -10C/90% - Air of extract
20C/50% and equal capacities between
supply and extract.
It is included also the function of automatic
defrosting made easy by the internal modulating rolling shutter and from the possible
modulation with intake flow.

Regulation
Costituted by power electric panel and pro Fans of supply and extract of plug-fan-type
grammable controller with integrated graphic
with synchronous motor with electronic condisplay. Everything is internally fitted in the
trol permanent magnetos (EC). The impellers
RPF could be integrated with traditional sysunit in an accessible position.
are oriented in such a way to grant an optimal
tems realized with fan coils, chillers, and
The function of regulation are:
air flow which goes through the internal comcould work both in winter and in summer.
1. Ventilation control (manual control of the
ponents, with the minimum noise.
This series is indicated for both horizontal
standard fans speed);
and vertical installation.
2. Thermo-regulation completed with all elec Air filtration with a filter with G4 efficiency
tric/electronic components (modality of reg(according to EN779) with low pressure drops
Configurations
ulation in standard extract);
on extracted air flow and a compact filter and
RPF_O Horizontal right supply (not availawith efficiency F7 (according to EN779) hav- 3. Integrated logics of energy savings: modulatble for size 42)
ing free-cooling / free-heating, anti-freeze,
ing a large filtrating surface made of glass
RPF_P Horizontal left supply (not available
night cooling, air quality control, dynamic
microfibre paper, inserted in the intake flow.
for size 42)
set point, speed economy of ventilation ,
The two typologies of filters are positioned
RPF_V Vertical right supply
ranges of time;
upstream of the components to be protected,
RPF_Z Vertical left supply
in order to grant low pressure drops, having a 4. Complete interfaceability with BMS sysEach of the different configurations could be furtems.
large surface available.
ther customized thanks to the choice of the
The filtrating cells are fixed on a proper bearaccessories (please refer to the technical docuing frame to avoid any by-pass of non-treated
mentation)
air. Their extractability is guaranteed from a
proper side opening (standard), superior or
The structure is formed by aluminium proinferior (optional) [with reference to the horifiles with thermic cut, connected by nylon
zontal version].
angles charged with glassfibre.
Static high efficiency cross-current heat
The sealing panels, of 50 mm thickness, are
recovery unit with high efficiency and aluof the sandwich type in pre-painted plate RAL
minium plate.
9002 (external) and galvanized sheet iron
The heat recovery unit guarantees the non(internal) insulated with polyurethane with

102

Functionality and technological advantages


The elimination from closed rooms of the polluting
elements, produced mainly from people and the
simultaneous external air input, are at the basis of
the concept of controlled mechanical ventilation
(VMC) of the internal rooms.
The purpose of ventilation is to raise the standard of
internal air quality with consequent positive effects
for health and productivity of the occupiers. The
change of air has positive effects also on the good
maintenance of the building.. For the building to be
requalified, the Controlled Mechanical Ventilation
is almost a mandatory choice in order to reach
high energy standards, which are imposed by the
current legislation.
VERY HIGH VENTILATION EFFICIENCY
Since the ventilation represents one of the
major factor of energy consumption, particular
attention has been given to the study and to
the creation of the ventilation system.
Fans of the plug-fan type with EC brushless
motors have been used both in supply and in
extraction; they permit high performances and
reduced consumptions. Furthermore, compared with the traditional centrifugal fans, they
don't have belts or pulleys with consequent
easiness of capacity regulation, compactness,
versatility, and an easy maintenance.
A particular adaptative logic permits to adjust
the effective air capacity required from the system with more consequent advatages in terms
of reduction of consumptions.
MAXIMUM EFFICIENCIES
In this context RPF is proposed as the high efficient and performing solution for double flow
ventilation systems with heat recovery.
The key-concept on which is based the RPF
proposal are:
Very high efficiency heat recovery attested by
EUROVENT certification and maintenance of
the complete separation of intake and discharge
air flow;
Reduced ventilation energy consumptions,
thanks to a detailed dimensioning of the components in order to have low total values of SFP
(Specific Fan Power or rather energy consumption for m3/h of total processed capacity);
High efficiency filtration and low pressure
drops;
Advanced electronic management for the energy saving and of controlling of internal pollutants functions VOC (Volatile Organic
Compounds);
Compactness of dimensions and logic of installation plug and play.

Basic configuration

RPF O Horizontal conguration


Right supply (seen from above)

RPF P Horizontal conguration


Left supply (seen from above)

RPF V Vertical conguration


Right supply (seen from the accessible side)

RPF Z Vertical conguration


Left supply (seen from the accessible side)

Legend: D = Discharge; I = Intake; S = Supply E = Extract

Fans off supply


with
motor with
l and
d extract off plug-fan-type
l f
h synchronous
h
h
electronic control permanent magnetos (EC)

AIR QUALITY IN ROOM


Particular attention has been given naturally
also to the quality of air in the room, standard
assigned to filters with efficiency G4 on extracted air flow and on compact filter with efficiency F7 included on intake air flow.
Naturally all these technological advantages are
controlled by a thermoregulation of last generation,
able to manage the different working procedures;
assuring the maximum energy saving in every
usage condition by using a proper software.

Static cross-current high efciency recuperator with aluminium plates.

103

Technical Data
Mod. RPF
Configurations
Nominal air flow (supply/extract)
Minimum air flow (supply/extract)
Maximum air flow (supply/extract)
Available static pressure (supply/extract)
Total recovered heating capacity
Performance in intake (EN308)

(1)
(1)

Fans
Fans Total input power
Input power
Total input current
Power supply

031
042

3100
4250
m3/h
1000
1300
m3/h
m3/h
3700
4600
Pa
250
225
kW
28,1
38,5
%
90
90
plug-fan
plug-fan
type
n
2
2
kW
1,55
2,50
kW
5,26
5,26
A
11,1
11,1
V/ph/Hz 230/1N/50Hz 230/1N/50Hz 230/1N/50Hz 230/1N/50Hz 400/3/50Hz 400/3/50Hz

Horizontal
Vertical

(2)
(2)
(2)

008

790
200
980
200
7,2
90
plug-fan
2
0,31
0,60
4,6

010

1000
200
1260
250
9,1
90
plug-fan
2
0,47
1,24
7,5

Cooling
(1) Air conditions: Intake10C, 90% UR; Extract 20C, 50% UR
(2) Unit in standard conguration without accessories
Note: For further informations please refer to the technical documentation available on the website www.aermec.com

104

013

1300
400
1530
250
11,8
90
plug-fan
2
0,66
1,26
7,5

020

2000
1000
2350
250
18,1
90
plug-fan
2
1,16
1,66
9,3

Dimensions (mm)

RPF 008031

RPF 008042

A
A

C
Horizontal Installation

Mod. RPF (Horizontal)


Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Mod. RPF (Vertical)


Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vertical Installation

(2)

008
450
1915
1054
194

010
450
1915
1258
220

013
524
2174
1374
264

020
560
2334
1694
328

031
700
2654
1948
452

042
-

(2)

008
1054
1915
450
194

010
1258
1915
450
220

013
1374
2174
524
264

020
1694
2334
560
328

031
1948
2654
700
452

042
1550
2974
1130
585

Cod.: SRPFUY.02 / 1502

(2) Standard con guration of unit with accessories


Note: For more information, refer to the selection program Magellano or the technical documentation available on the website www.aermec.com

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

105

HRS

Heat recovery unit

HORIZONTAL INSTALLATION
These units allow to extract a determined amount of air from the environment and replace it with fresh air.
An aluminium plate recovery unit allows effective heat exchange between the expulsion air flow and that of fresh air: the fresh air is pre-heated or
pre-cooled in this way, depending on the season, at the cost of the expelled air.
The air introduced is filtered before passing through the recovery unit, which is protected from dirtying with a filter of the same type also on the
expulsion side. The air introduced can also be post-heated int he versions with hot water heating coil.

Features
Available in 8 sizes and 2 versions:
polyethylene/polyester with average thickness of Terminal board on machine to ease the electric
HRS: standard version
20 mm.
connections and fan control.
HRS W: version with additional hot water coil. Condensate drip tray in ABS (030-300) INOX Aluminium plate heat recovery unit housed in
It is used when post-heating is necessary.
(390) with low condensate drain connection.
condensate drip tray.
Available in models from 090 to 390.
Air filters with G4 efficiency, easily extractable
Horizontal installation.
laterally, to allow periodical cleaning.
Panels realised in Aluzink sheet steel, remova- Double intake centrifugal fans, coupled directly
ble for inspection and maintenance.
onto electric motors (with single intake for HRS
Acoustic and heat insulation of the panels using
030).

106

Accessories
HRS_CS: Section of water cooling/heating HRS_S: N 4 circular connection kits for
(with stainless steel condensate drip tray).
direct connection of the unit to the circular
ATTENTION
conduits.
the standard version of section HRS_CS he
- HRS030S ( 200 mm)
attacks battery claims, it goes to the HRS and
- HRS090S ( 315 mm)
HRS_W oriented type 03 (standard) and type
- HRS160S ( 315 mm)
02. For the HRS guidelines and HRS_W with
- HRS190S ( 355 mm)
type 01 and type 04, you must request at time
- HRS230S ( 400 mm)
of order, the section HRS_CS with attacks HRS_SC: Electronic speed regulator.
right battery.
HRS_AT: Anti-freeze thermostat, allows to
HRS_ED: Regulation shutter.
control that the temperature does not fall

HRS030

HRS030CS
HRS060CS
HRS090CS
HRS160CS
HRS190CS
HRS230CS
HRS300CS
HRS390CS

HRS090
HRS090W

HRS060

HRS160
HRS160W

HRS300
HRS300W

HRS390
HRS390W

HRS030S
HRS090S
HRS160S
HRS190S
HRS230S

HRS030SC
HRS060SC

HRS01AT
PX
PX2

HRS_CS
160
600
500
450
290
310
3/4
22
21

190
700
500
480
310
330
3/4
22
24

230
700
600
660
410
410
3/4
22
29

300
700
600
660
410
410
3/4
22
29

390
700
600
710
410
410
3/4
22
34

A
1
B

090
500
410
450
260
210
3/4
22
17

060
430
290
395
250
230
3/4
22
14

030
430
290
395
250
230
3/4
22
14

FRESH
AIR

AIR
EXPELLED

mm
mm
mm
mm
mm
mm
mm
kg

HRS230
HRS230W

HRS030ED
HRS090ED
HRS160ED
HRS190ED
HRS230ED

A
B
C
D
E
1
2
Peso

HRS190
HRS190W

below a pre-established value. Accessory


installed in the factory, to be requested when
placing the order for the HRS/HRS_W version.
PX: Control panel with switch-over.
Wall installation. (from size 090 to 300)
PX2: Control panel with switch-over.
Wall installation. (from size 090 to 300)
Compatibility with the VMF system
For further system information please refer to
the specific documentation.

REGULATION SHUTTER (HRS_ED)

A
B

mm
mm

030 090 160 190 230


210 210 310 310 410
180 260 290 330 410

KIT 4 CIRCULAR CONNECTION (HRS_S)

D
P

mm
mm

030
200
50

090
315
100

160
315
100

190
355
100

230
400
100

107

Technical data
Model
Nominal air ow rate
Useful static pressure 1
Total max input
Sound pressure 2
FANS
Fans
Power
Poles
Number of speeds
Protection rating
Isolation class
Power supply

m3/h
Pa
A
dB(A)
n
W
n
n
IP

HRS030
300
265
1,2
47

HRS060
620
55
1,8
51

HRS090
920
65
2,2
50

HRS160
1580
70
4,4
53

HRS190
1850
77
4,8
52

HRS230
2250
80
5,2
51

HRS300
2950
100
8,3
54

HRS390
3920
100
5
56

2
90 x 2

2
90 x 2

2
147 x 2

2
350 x 2

2
350 x 2

2
350 x 2

2
550 x 2

2
750 x 2

55

44

24
55

4
13

34
44
F

V/Ph/Hz

230/1/50Hz

400V/3N/50Hz

RECUPERATOR
Efciency
Recovered heating capacity
Conditioned air temperature

%
kW
C

53
1,5
8,3

54
3,1
8,5

55
4,7
8,8

54
7,9
8,5

54
9,2
8,5

54
11,2
8,5

51
13,9
7,8

57
20,6
9,3

Efciency
Recovered heating capacity
Conditioned air temperature

%
kW
C

46
0,27
29,2

47,7
0,58
29,1

48,6
0,88
29,1

47,5
1,48
29,2

47,3
1,73
29,2

47,5
2,11
29,2

45,1
2,63
29,3

49,8
3,86
29,0

HRS300W
24.2

HRS390W
29.9

22

22

31.3
33
22

29.7
43
30

6.5

FILTERS
Efciency

G4

Features of the water post-heating coil (HRS W)


Model
Heating capacity
kW
Geometry
Pipes for row
n
Rows
n
Louver pitch
mm
Air outlet temperature
C
Air side pressure drop
Pa
Water side pressure drop
kPa
Collectors diameter

Weight
kg
The performance refers to the following conditions
1. Values referring to the nominal air flow rate
including recovery unit and filters G4
2. Noise pressure level: values referring to
1.5 m from machine intake in free field

/
/
/
/
/
/
/
/
/
/
3.
4.

Features of the water post-heating/cooling coil (HRS_CS)


Geometry
Pipes for row
n
Rows
n
Louver pitch
mm
Heating capacity
kW
Air outlet temperature
C
Water flow rate
m3/h
Water side pressure drop
kPa
Air side pressure drop
Pa
Cooling capacity
kW
Sensitive cooling capacity
kW
Air outlet temperature
C
Water flow rate
m3/h
Water side pressure drop
kPa
Air side pressure drop
Pa
The performance refers to the following conditions

108

/
/
/
/
/
/
/
/
/
/

HRS090W
8.2

HRS160W
12.2

14

18

33.4
25
8

30.8
32
14

2.5

2.5

Electronically adjustable regulator HRS_SC


Selectable control panel

030
25x22
13
3
2,1
4,7
52,8
0,4
3
10
2
1,3
16,9
0,3
3
20

060
25x22
13
3
2,1
8,2
45,6
0,7
7
13
3,5
2,3
18,7
0,6
7
30

HEATING
air input temperature
water input temperature
water output temperature
Nominal air flow

090
25x22
16
3
2,1
12
45
1,1
6
27
5
3,3
19
0,9
6
38

HRS190W HRS230W
14.4
20.3
25x22
18
22
2
2.5
30.2
33.2
30
25
15
17
3/4"
2.5
5

Winter nominal conditions:


external air temperature
environmental air temperature
Summer nominal conditions:
external air temperature
environmental air temperature
160
25x22
22
3
2,1
19,7
43,4
1,7
20
38
8,8
5,8
18,9
1,5
21
48
8C
70C
60C

190
25x22
25
3
2,1
23,7
44,5
2,1
34
34
11,1
7,2
18,7
1,9
39
45

230
25x22
26
3
2,1
30,5
46,5
2,7
30
25
14,7
9,4
17,3
2,5
36
35

-5 C BS, UR 80 %
20 C BS, UR 50 %
32 C BS, UR 50 %
26 C BS, UR 50 %

300
25x22
26
3
2,1
37
43,7
3,3
43
38
17,4
11,4
18,3
3
49
52

COOLING
air input temperature
relative Humidity
water input temperature
water output temperature
Nominal air flow

390
25x22
26
3
2,1
46,2
41,5
4,1
36
50
20,9
13,9
19,3
3,6
39
65
30C
50%
7C
12C

Internal layout (configurations available)


The guidelines are depicted relative to the car top
view

FRESH AIR
AIR ECPELLED

ORIENTATION TYPE 01

ORIENTATION TYPE 02

HRS_CS Section of water cooling/heating

(with stainless steel condensate drip tray).


densa

Post heating coil

ORIENTATION TYPE 03
STANDARD CONFIGURATION

only HRS_W version

ORIENTATION TYPE 04

Dimensional data (mm)

ORIENTATION TYP 03

ORIENTATION TYP 04

FILTER G4

B
(mm)
290
290
410
500
500
600
600
600

C
(mm)
750
750
860
860
960
1230
1230
1330

D
(mm)
240
240
260
290
310
410
410
410

D1
(mm)
79
79
95
77
87
91
91
116

DIMENSIONS
D2
(mm)
79
79
115
77
87
91
91
116

E
(mm)
180
180
210
310
330
410
410
410

F
(mm)
100
220
220
225
225
288
321
321

F1
(mm)
94
90
115
109
129
152
135
160

G
(mm)
100
90
200
255
255
255
280
280

G11
(mm)
/
/
3/4
3/4
3/4
3/4
3/4
3/4

WEIGHT
Y
(mm)
95
130
50
75
75
162
125
125

(kg)
41
45
80
125
138
160
174
190

ATTENTION
1. Hydraulic connections of the battery post-heating
THIS JUST IN VERSION HRS_W
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

109

Cod.: SHRSUY.05 / 1401

HRS030
HRS060
HRS090
HRS160
HRS190
HRS230
HRS300
HRS390

A
(mm)
990
990
1140
1300
1380
1650
1650
1750

URX CF

Heat recovery unit


with refrigerant circuit.
Air ow from 750 to 3,300 m3/h.

R410A

The URX_CF series is the mono-bloc solution designed for the installation requirements typical for public spaces like bars,
restaurants, ofces, meeting rooms.
The URX_CF units combine in one mono-bloc unit, besides the fan, lter, and heat recovery sections, a heat pump refrigerant circuit
with scroll compressors of high output and low noise.
The supply air is heated or cooled, based on the season, through the heat pump refrigerant circuit located within the unit and
charged with refrigerant R410A. All this allows to have a complete unit, with the automatic operation in each season and capable of
combining the required space ventilation requirements with efcient heat recovery.
The careful design of the machine combines very compact dimensions, which permit easy installation in false ceilings, with an
excellent accessibility for maintaining all the internal components.

Characteristics
VERSIONS
Standard horizontal configuration
5 sizes complete with temperature controller
and ready for installation.

drive motor. Single phase 230V-50Hz single


speed motor. The air flow is controlled, within
+/- 15% of the nominal, through an electronic
speed controller supplied as standard.

PANELS:
REFRIGERANT CIRCUIT:
Self-supporting sandwich panel 20 mm thick in Heat pump complete with high efficiency low
galvanised steel for internal and external surfacnoise scroll compressors, 4 way refrigerant
es with injected polyurethane insulation (densicycle reversing valve, evaporator coil, condensty 40 kg/m3).
er coil, liquid receiver, liquid separator, double
thermostatic expansion valve, liquid sight glass
HEAT RECOVERY:
(only for models 150, 210, 330), filter drier,
Cross flow plate heat exchanger in aluminium
high/low pressure pressostats.
with outputs over 50% in winter conditions.
ELECTRICAL PANEL:
FILTERS:
The unit is provided with an electrical panel
Class G3, 80% gravimetric efficiency, according
complete with power and control section
to EN 779, thickness 48 mm, located before the
(included the control for the 3 way valve for the
heat recovery both in the supply and return air
supplementary hot water coil and associated
flow.
actuators), ensuring the control of all the refrigerant circuit functions. Included are: NTC return
CENTRIFUGAL FANS:
air temperature sensor, external air temperature
Double inlet forward curved blades with direct
sensor, dampers and actuators in the free-cool-

110

ing version, pressure switch in the supply air filter. Supplied loose is a remote mounted control
terminal for automatic control of the unit and an
outlet to power and control a light to conform
with the current regulation for smoking zones.
CONDENSATE DRAIN TRAY:
Condensate drain tray in aluminium.
ACCESSIBILITY:
From below for the heat recovery, the filters, the
condensate drain tray and the fans.

Accessories

MBC casing with 2 row hot water coil to


install on the supply air. Includes the three
way valve and on-off actuator.

FCE free-cooling complete with controls

to be added to the existing. Free-cooling


operation only works in the summer mode,
if the external air temperature is at least
10K lower than the internal air temperature
and if the compressor safeties permit it.

FGC circular anges. Each accessory


consists of a ange to be connected to
each unit's rectangular connection.
G4F lter efciency G4
MBX casing with single stage electrical
heater with shrouded nned elements,
with double safety thermostat of manual
and automatic reset type, to install on the
supply air.

URX_CF
RS485
FCE
FGC
G4F
MBC
MBX
SUF

SUF silencer splitter module, in


appropriate casing. The accessory consists
of two modules: one for the supply and
one for the return.
RS485 board RS485

07

10

15

21

33

07
07
07
07
07
07

10
10
10
10
10
10

15
15
15
15
15
15

21
21
21
21
21
21

33
33
33
33
33

Filters class G3 EN779 in


supply and return
Integrated heat pump refrigerant
circuit with scroll compressor

Reduced height for false


ceiling installations

Unit fitted with temperature controller


with unit mounted electrical panel
Electronic speed controller supplied as
standard, to calibration the fan speed

111

Technical data
Mod. URX_CF
Air flow nominal supply and extract
Air flow minimum
Available supply static pressure (max)
Available extract static pressure (max)
Heating capacity total (heat recovery + refrigerant circuit)
Total cooling capacity (heat recovery + refrigerant circuit)
Heating capacity available
Cooling capacity available
Efficiency heat recovery
Fans
Total fans nominal power input
Total fans maximum current input
N
Compressors
Gas
Compressor power input winter condition
Compressor power input summer condition
Maximum compressor current input
Total power input winter condition
Total power input summer condition
Sound pressure level at 1 m
Power supply
MBC - Hot water coil (accessory)
Number of rows
Air side pressure drop (nominal air flow)
Heating capacity
Heating capacity
Water flow rate at nominal conditions
Water pressure drop (nominal conditions)
Water flow rate at nominal conditions
Water pressure drop (nominal conditions)
MBX - Electric heating coil (accessory)
Power supply
Heating capacity
Air side pressure drop (nominal air flow)
Number of stages
Electric heater current input
CONNECTION DIAMETERS
Drain pan condensate discharge diameter
Water coil connection diameter

Pa
Pa
kW
kW
kW
kW
%

07
750
640
298
248
8,8
6,1
2,4
1,4
46,2

10
1000
850
250
218
10,8
7,3
2,3
1,7
51,2

15
1500
1275
250
233
15,8
10,2
3,0
2,2
53,2

21
2100
1785
166
163
22,8
15,0
4,8
3,4
53,6

33
3300
2800
280
273
33,3
23,0
5,2
5,1
53,6

n
kW
A

0,92
4,20
2

0,92
4,20
2

0,92
4,20
2

0,92
4,20
2

1,5
6,80
2

kW
kW
A
kW
kW
db(A)

R410A
1,3
1,8
8,2
2,0
2,6
53
230V/1/50Hz

R410A
1,3
2,1
12,5
2,0
2,8
55
230V/1/50Hz

n
Pa
kW
kW
l/h
kPa
(/h
kPa

2
11
5
1,9
442
16
336
11

2
18
6
2,2
523
22
382
14

kW
Pa
n
A

3
10
1
4,6

in
in

1
3/4

m3/h
(1)
(1)

(2)
(3)
(2)
(2)
(3)
(3)

R410A
R410A
R410A
1,8
2,5
3,0
2,3
3,5
4,4
7
11,1
19,7
3,3
4
5,5
3,8
5
6,9
57
59
62
400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz

2
23
8,7
3,4
763
9
584
6

400V/3/50Hz (separate power supply to the unit)


4,5
6
9
10
10
10
1
1
1
6,8
9,1
13,7
1
3/4

1
3/4

Heating
fresh air flow equal to the exhaust air flow; external air temperature (in) -5C 80% r.h.; room air temperature 20C, 50% r.h.
Cooling
fresh air flow equal to the exhaust air flow; external air temperature (in) 34C 50% r.h.; room air temperature 26C, 50% r.h.
(1) Fan power supply 230V; nominal air flow rate without accessories
(2) Water temperature (in/out) 70/60C; operating as in heating mode; with compressor operating
(3) Water temperature (in/out) 45/40C; operating as in heating mode; with compressor operating
Sound pressure: at 1 m in free field with ducted vents

112

2
42
10,3
3,7
902
12
638
7

1
3/4

2
78
16,8
7,5
1475
31
1306
28

12
10
1
18,2
1
3/4

Dimensional data (mm)

C
B

A
B
C

mm
mm
mm
kg

07
450
1300
1500
205

10
450
1300
1500
218

15
550
1500
1800
272

21
550
1500
1800
298

33
600
1600
1800
328

Cod.: SURXUY.02 / 1501

URX_CF
Height
Width
Depth
Weight

All specifications are subject to change without prior notice.


Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

113

URHE_CF

High-efciency heat recovery unit with


cooling circuit without an external unit.
Air ow rates from 1,000 to 3,300 m3/h.

R410A
TECHNOLOGY

HIGH
EFFICIENCY

Features
The units from the URHE_CF series represent a
high-efficiency solution to satisfy the temperature and humidity comfort and ventilation
requirements in air conditioning systems that
serve public spaces and the commercial sector,
such as offices, bars, restaurants, etc.
The URHE_CF units are particularly efficient
units in that they use a high yield cross flow
plate heat exchanger of high capacity combined
with a heat pump cooling circuit operating with
refrigerant R410A.
The use of a high yield cross flow heat recovery
unit permits a significant reduction in the operating time of the cooling circuit throughout the
year, thereby reducing to the minimum the electrical energy consumption.
The small unit dimensions allow for easy installation even in suspended ceilings, allowing
excellent accessibility for the maintenance of all
the internal components.
The numerous accessories available on request,
for example the high-efficiency compact filters,
the hot water coil or the silencers, complete the
functions of the unit, which is usually combined
to an air conditioning system.

STRUCTURE AND PANELS:


valve, bypass valve (for the smaller sizes).
Structure in aluminium profiles with glass
fibre reinforced nylon corner pieces.
ELECTRICAL PANEL:
Sandwich panel 25 mm thick with galvanised The unit is provided with an electrical panel
steel for the internal surface, prepainted for
complete with power and control cross-secthe external surface with injected polyuretion (including the control for the 3 way valve
thane insulation (density 42 kg/m3).
for the supplementary hot water coil and
associated actuators), ensuring the control of
HEAT RECOVERY:
all the cooling circuit functions. Included are:
Cross flow plate heat exchanger in aluminium
NTC return air temperature sensor, external
optimised to ensure high outputs.
air temperature sensor, dampers and actuators
in the free-cooling version, manostat on the
PLEATED FILTERS:
flow filter. Supplied loose is a remote control
Class G4, 80% gravimetric efficiency accordterminal for automatic control of the unit.
ing to EN 779, thickness 48 mm, located
before the recovery unit both in the supply ENVIRONMENTALLY FRIENDLY:
and return air flow.
Through the applied technology and the use
of ozone friendly refrigerant R410A, the
CENTRIFUGAL FANS:
URCHE_CF series is environmentally friendly.
Forward curved impellers with directly couR410A is a refrigerant with high thermodypled high static pressure motor. The air flow
namic efficiency and this, together with the
rate is maintained constant by the use of an
use of scroll compressors, allows for reduced
electronic controller.
CO2 emissions.

COOLING CIRCUIT:
Heat pump with refrigerant R410A, complete
VERSIONS
with high-efficiency low noise rotary or scroll
4 sizes available in horizontal configuration
compressors (depending on size), 4 way cycle
for ground or suspended ceiling installation.
reversing valve, evaporator coil, condenser
Unit complete with temperature controller
coil, liquid receiver, thermostatic valve, liquid
and ready for installation.
sight glass, dehydrator filter, high pressure
manostat, low pressure manostat, safety

114

Accessories

MBCH hot water coil module


MBCX electric coil module
FCT high-efficiency compact filters F7
BIT base for floor mounting
BIM base for floor mounting for additional
modules

TPE roof for external installation

TPM roof for external installation of addi-


tional modules
FCH free-cooling kit
RS485 board RS485
MSS n 1 silencer splitter module

URHE_CF
MBCH
MBCX

TPMSS roof for silencer splitter module


FGE circular flanges

10
MBCH1
MBCX1

15
MBCH1
MBCX2

25
MBCH1
MBCX3

33
MBCH2
MBCX4

FCT

FCT1

FCT1

FCT2

FCT3

BIT

BIT1

BIT1

BIT2

BIT3

BIM

BIM1

BIM1

BIM1

BIM1

TPE

TPE1

TPE1

TPE2

TPE3

TPM

TPM1

TPM1

TPM1

TPM2

FCH

FCH1

FCH1

FCH2

FCH2

RS485

RS485

RS485

RS485

RS485

MSS
TPMSS
FGE

MSS1

MSS1

MSS2

MSS2

TPMSS1

TPMSS1

TPMSS1

TPMSS2

FGE1

FGE1

FGE1

FGE1

Filters class G4 EN779 in


supply and return

High-efciency plate heat


exchanger

Remote panel
(standard)

Standard inverter for fans to maintain


constant air ow rate

High-efciency heat pump


cooling circuit

Unit tted with thermoregulation


with unit mounted electrical
panel

115

Technical data
URHE_CF
Maximum air flow and recovery flow rate
Air flow minimum
Available flow and return static pressure
Heating capacity recovered
Cooling capacity recovered
Total heating capacity (recovery unit + compressor)
Total cooling capacity (recovery unit + compressor)
Available heating capacity
Available cooling capacity
RECOVERY UNIT
Efficiency in winter condition
Efficiency in summer condition
FANS
Number of fans
1 fan maximum input power
1 fan maximum input current
Heating total input power
Cooling total input power
Protection rating
Sound power level
FILTERS (standard)
EN779 Classification
Gravimetric efficiency
EN779 Classification (accessory filters)
Additional pressure drop for filters F7 (accessory)
COOLING CIRCUIT (COMPRESSOR)
Refrigerant
Compressor maximum current input
CONDENSATE DRAIN TRAY
Condensate drain tray discharge diameter
MBCH - HOT WATER COIL (accessory)
Rows
Air side pressure drop (nominal flow rate)
Heating capacity
Heating capacity
Water flow rate at nominal conditions
Water side pressure drop (nominal conditions)
Water flow rate at nominal conditions
Water side pressure drop (nominal conditions)
Water coil manifold diameter
MBCX - Electric heating coil (accessory)
Power supply
Heating capacity
Air side pressure drops (nominal flow rate)
Stages
Electric coil current input

(1)
(2)
(3)
(2)
(3)
(2)
(3)

10
1000
800
320
7
2.2
10.9
6.6
2.8
1.8

15
1500
1100
245
10
3.2
14.2
8.7
2.9
3.1

25
2500
2000
140
15.3
4.5
24.8
13.8
3.9
3.3

33
3300
2500
220
19.6
5.8
33.1
19.8
7
5.4

(%)

82
82

80
80

73
68

71
65

(kW)
(A)
kW
kW
IP
dB(A)

2
0.42
3.10
2.2
2.6
55
66

2
0.46
3.10
2.4
2.9
55
69

2
1.1
5.3
4.2
5.1
55
72

2
1.1
5.3
4.9
6.5
55
75

(Pa)

G4
90
F7
35

G4
90
F7
59

G4
90
F7
58

G4
90
F7
63

(A)

R410A
10

R410A
11

R410A
7

R410A
10.3

(in)

(n)
(Pa)
(kW)
(kW)
(l/h)
(kPa)
(l/h)
(kPa)
(in)

2
7
7.7
2.6
673
11
446
3
3/4

2
18
10.3
4
906
8
700
6
3/4

2
37
15.6
6.5
1363
18
1118
14
3/4

2
37
19.7
7.6
1725
32
1311
22
3/4

(kW)
(Pa)
(n)
(A)

400V/3/50Hz (separate power supply from the unit)


5
7.5
12.5
16.5
10
10
10
10
1
1
1
1
7.6
11.4
19
25.1

(Pa)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(%)

(2)
(3)

(%)

(4)
(5)
(4)
(4)
(5)
(5)

(1) Fan power supply: 230V; nominal air ow rate; without accessories;
(2) Fresh air flow rate equal to exhaust air flow rate: incoming external air temperature -5C, 80% UR; Room temperature 20C, 50% UR
(3) Performance referring to: fresh air flow rate equal to exhaust air flow rate; incoming external air temperature 34C, 50% UR; room temperature 26C, 50% UR.
(4) Performance referred to: inlet/outlet water temperature 70/60C; at conditions 2) with compressor operating
(5) Performance referred to: inlet/outlet water temperature 45/40C at conditions 2) with compressor operating
Sound power level of the flow fan not ducted with useful static pressure equivalent to 0 Pa.

(1) Fan power supply: 230V; nominal air ow rate; without accessories;
Cooling
(2) Operating conditions: return air 26C 50%, external air 34C 50%;
Heating
(3) Operating conditions: return air 20C 50%, external air -5C 80%;
(4) This value offers an indication of the capacity produced by the unit net of the capacity used to bring the external air conditions to neutral values (specically, 20C with
50% UR in winter and 26C with 50% UR in summer)
(5) At 1 m distance in free eld with ducted connections.
(6) Inlet/outlet water temperature 70/60C. Compressor operating. Operating conditions: return air 20C 50%, external air -5C 80%;
(7) Inlet/outlet water temperature 45/40C. Compressor operating. Operating conditions: return air 20C 50%, external air -5C 80%;

116

Dimensions (mm)

URHE_CF
Height
Width

A
B

(mm)
(mm)

10
580
1640

15
580
1640

25
580
1640

33
580
1970

Depth

(mm)

1500

1500

1990

2310

(kg)

300

310

373

410

Code: SURHECFUY.04 / 1501

Weight

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

117

ERS

High-efciency heat recovery


unit with static recovery unit.
Air ow rates from 1,000 to 5,000 m3/h.

TECHNOLOGY

HIGH
EFFICIENCY

MECHANICALLY CONTROLLED VENTILATION


STATIC HEAT RECOVERY UNIT
AIR PURIFICATION
Features
The ERS heat recovery units for indoor and outdoor installation are designed for commercial
applications and are able to combine maximum
environmental comfort with definite energy savings.
With modern systems, there is always the need
to create forced ventilation, which, however,
also involves expelling air-conditioned air,
which thus leads to higher energy consumption.
But ERS units are equipped with a static heat
recovery unit that enables you to save part of
the energy that would otherwise be lost with the
expelled stale air.

Versions
ERS_B
with a standard static recovery unit
(without adjustment)
ERS_T
with a static recovery unit with
by-pass total T (without adjustment)

Aluminium plate heat recovery unit, with


countercurrent flows, high-efficiency and low
pressure drops
Air filters (flow and recovery) with G4 corrugated setting, the return filter can be supplied
with a differential pressure switch.
The filters are extractable on both sides to
facilitate their periodic cleaning.
These units can be integrated with fan coils and Fans (intake and flow), centrifugal fans with
front curved blades and a directly coupled,
chillers, and can operate both in winter and
electronically controlled motor.
summer.
Support frame and sandwich panels, 25 mm
thick, in galvanised sheet steel for internal
surfaces and pre-painted externally, and insu-

lated with injected polyurethane (density


42kg/m3).
Base in galvanised sheet steel continuous profiles. The unit can be inspected from both
sides.
The unit can be fitted in the factory and therefore, when ordering, can provide for an electric control board on the machine (accessory),
with three different types of adjustment, purposely studied to reduce energy consumption.
1. With manual control of the flow rate (CMF)
2. Maintaining a constant flow rate (CPOC)
3. Maintaining constant static pressure
(CPRC) Naturally, there are also different
communication interfaces always available as
accessories (RS485, MODBUS, master/slave).

Accessories

BLM Hopper flow outlets.


GAR fresh air intake anti-vibration joint.
GAE expelled air intake anti-vibration joint.
CAR fresh air intake cuff.
CAE expelled intake cuff
FCR fresh air circular flange.
FCE expulsion circular flange.
GMR fresh air flow anti-vibration joint
GME expelled air flow anti-vibration joint
BLE hopper light expulsion.
HBA integrated direct expansion coil R410A.
HBC integrated direct expansion coil R407C
HBW integrated water coil.
HBX_S upper pre-heating electric coil
HBX_I lower pre-heating electric coil
HFT_S upper bag filters
HFT_I lower bag filters
HSR fresh air intake damper
HSE intake damper expulsion
TP roof protection.

118

HPF filter pressure switch on outdoor air


intake
V3V 3-way valve
Adjustment Accessories
It is compulsory to select 1 of the 3 following
types of fan adjustments
CMF manually controlled flow rate adjustment
CPOC constant flow rate controlled adjustment
CPRC constant static pressure control adjustment
PRK Remote terminal
EVS485 RS-485 interface for supervising systems with MODBUS protocol
EVSEH Ethernet Modbus interface board
EVSPFB Profibus DP Slave-V interface board
SRE ON/OFF servo control for external air
damper
SRME ON/OFF servo control with spring

return for external air damper


SRR - ON/OFF servo control for return air
damper
SRMR - ON/OFF servo control with spring
return for return air damper
AFT Anti-freeze thermostat for HBW
V3VR 3-way valve V3V
SPR Recovery pressure probe
SVOC VOC probe
SCO2 CO2 probe
QEX Electric control board for HBX electric
coils

Unit without adjustment

Yalit the air


Ed

,'




K


Air circlatin is thanks t the centrigal ans ith


electrnicall cntrlled mtrs
d
d

High-eicienc recer nit
(80 the energ the eelled air)




Freecling: ree cmrt
/
ERS_T (ith -ass)



Unit with adjustment

State the art electrnic cntrl


d

 D(CMF)
 D(CPOC)
 D(CPRC)

119

Accessories compatibility
Md. ERS
MECHANICAL ACCESSORIES
GAR
GAE
CAR
CAE
FCR
FCE
GMR
GME
BLE
HBA
HBC
HBW
HBX_S
HBX_I
HFT_S
HFT_I
HSR
TP

Md. ERS
WITHOUT CONTROLLER AND ELECTRIC
POWER BOARD
HPFE

HPFR

V3V

AFT
SRE

SRME

SRR

SRMR

10
B
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

B
20
20
10
20
20
20
20
20
20
10
10
10
20
20
10
10
10
10

10
B

Md. ERS
10
ADJUSTMENT and ACCESSORIES
B
It is cmlsr t chse ne rm CMF/CPOC/CPRC
CMF
10
CPOC

10
CPRC

10
CCO2

CVOC

Adstment accessries
PRK

EVS485

EVSEH

EVSPFB

SRE

SRME

SRR
SRMR
AFT
V3VR1
V3VR2
QEX
HPFE
HPFR

20

30
T
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

B
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30

40
T
20
20
30
20
20
20
20
20
20
30
30
30
20
20
30
30
30
30

B
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40

10
10
10

50
T
30
30
40
30
30
30
30
30
30
40
40
40
30
30
40
40
40
40

B
40
40
50
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50

10
10
10

30
30
30

10
10
10

40
40
40

30
30
30

50
50
50

40
40
40

20

30

20

40

30

T
40
40
50
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50

40

50

(1) Installed on the machine and complete with pressure plugs (without cables)
(2) Supplied with a modulating servocontrol 0 10 V, 24Vac power supply, cable length 0.15m. Provide for anti-freeze protection for the hot water coil.
(3) Supplied without a connection cable between it and the unit; if provided with adjustment, the basic unit is already supplied with a controller on the machine with an LCD display.
(4) The choice of one, excludes the others (for other needs, contact the head ofce)
(5) Installed on the machine and complete with pressure plugs;
(6) From the pressure probe on the fan.
(7) From the pressure probe on the duct.
(8) No. 1 servo control for damper. Power supply 24Vac.
(9) Compulsory in the case of a promiscuous or hot coil.
(10) Compulsory in the case of HBX pre-heat coils
(11) Compulsory accessory in the case of a promiscuous or hot coil.
(12) From duct air quality probe

120

Technical data
ERS
VERSION
Nominal air flow and recovery flow rate
Maximum air flow and recovery static pressure available
Recovered thermal power
Winter recovery unit efficiency
Recovered cooling capacity
Summer recovery unit efficiency
Total number of fans
Each fan max. input power
Each fan max. absorption current
Power supply

m3/h
Pa
kW
%
kW
%
n
kW
A
V/ph/Hz

Sound pressure level

dB(A)

HBW Water coil


Total cooling capacity
Heating capacity
Heating capacity
HBC Direct expansion coil R407C
Total cooling capacity
Heating capacity
HBA Direct expansion coil R410A
Total cooling capacity
Heating capacity

(1)
(2)
(3)

kW
kW
kW

(4)
(5)

kW
kW

(6)
(7)

kW
kW

10
B
1000
340
8.8
82.4
2.1
69.2
2
0.52
3.4

B
2000
340
17.7
82.4
4.2
69.2
2
0.52
3.4

20
T
1000
410
9
83.9
2.1
70.4
2
0.52
3.4

30
40
B
T
B
T
3000 2000 4000 3000
280
360
460
280
26.5 17.8 35.1 26.5
82.4 83.2
82
82.4
6.3
4.2
8.3
6.3
69.2 69.9 68.8 69.2
2
4
4
2
1.9
0.9
1.9
1.9
8.3
4.0
8.3
8.3
230V/1/50Hz

B
5000
350
44.1
82.4
10.4
69.2
4
1.9
8.3

50
T
4000
410
35.5
82.8
8.4
69.5
4
1.9
8.3

24.8

26.9

23.3

29.3

25.3

31.6

32

36.5

33.3

10

10

10

30

30

40

40

50

50

10.7
12.9
6.8
10
11.1
8.4
10
12
8.5

17.6
21.5
11.4
10
15.9
13.6
10
18.1
13.7

10.7
12.7
6.7
10
11.1
8.3
10
12.1
8.3

28.4
33.4
17.7
30
24.4
20.8
30
27.7
20.9

21.6
24.6
13
30
20.1
15.6
30
22.2
15.7

37.2
44
23.4
40
31.8
27.4
40
36.2
27.6

30.6
35.5
18.9
40
27.6
22.5
40
30.9
22.6

48.9
56.7
30.1
50
41.5
35.1
50
47
35.3

42.2
47.9
25.4
50
37.5
30
50
41.8
30.2

Heating
Fresh air flow rate equal to the air expulsion flow rate; outdoor air temperature (in) -10C 90% r.h.; room temperature 22C, 50% r.h.
Cooling mode
Fresh air flow rate equal to the air expulsion flow rate; outdoor air temperature (in) 35C 50% r.h.; room temperature 26C, 50% r.h.
(1) Water coil temperature (in/out) 7/12C; Outdoor air temperature (in) 35C 50% r.h.; room temperature 26C, 50% r.h.
(2) Water coil temperature (in/out) 70/60C; Outdoor air temperature (in) -10C 90% r.h.; Room temperature 22C, 50% r.h.
(3) Water coil temperature (in/out) 45/40C; Outdoor air temperature (in) -10C 90% r.h.; Room temperature 22C, 50% r.h.
(4) Evaporation temperature 5C; Condensation temperature 50C; Outdoor temperature (in) 35C 50% r.h.; room temperature 26C, 50% r.h.
(5) Evaporation temperature 0C; Condensation temperature 50C; Outdoor temperature (in) -10C 90% r.h.; room temperature 22C, 50% r.h.
(6) Evaporation temperature 5C; Condensation temperature 50C; Outdoor temperature (in) 35C 50% r.h.; room temperature 26C, 50% r.h.
(7) Evaporation temperature 0C; Condensation temperature 50C; Outdoor temperature (in) -10C 90% r.h.; room temperature 22C, 50% r.h.
Sound pressure: at 1 m in free field with directivity factor 2.

Dimensional data (mm)

ERS
Height

(mm)

10
1300

20
1300

30
1300

40
1300

50
1300

Width

(mm)

900

900

1300

1600

2100

Length

(mm)

1900

1900

1900

1900

1900

(kg)

290

315

373

453

531

Weight

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

121

Code: SERSUY.04 / 1501

ERSR

High-efficiency heat recovery


high-efficiency with rotary recovery unit.
Air flow rates from 1,000 to 30,000 m3/h.

TECHNOLOGY

HIGH
EFFICIENCY

MECHANICALLY CONTROLLED VENTILATION


ROTARY HEAT RECOVERY UNIT
RECOVERY OF UP TO 80% OF THE ENERGY OF THE
EXPELLED AIR
AIR PURIFICATION
Features
The ERSR heat recovery units for indoor and
outdoor installation are designed for commercial applications and are able to combine maximum environmental comfort with definite energy saving.
With modern systems, there is always the need
to create forced ventilation, which, however,
also involves expelling air-conditioned air,
which thus leads to higher energy consumption.
But ERSR units are equipped with a rotary heat
recovery unit (upon request, also hygroscopic
rotary) that enables you to save more than 80%
of the energy that would otherwise be lost with
the expelled stale air.
These units can be integrated with fan coils and
chillers, and can operate both in winter and
summer.

Support frame and sandwich panels, 50 mm


thick, in galvanised sheet steel for internal
surfaces and pre-painted externally, and with
mineral wool insulation (density 40 kg/m3).
Upon request, there are two different types of
panelling.
Base in galvanised sheet steel continuous profiles. Sizes 07 to 09 are monoblocs whilst the
other sizes are divided into sections. The unit
Rotary heat recovery unit (with the option in
can be inspected from both sides.
hygroscopic material), high-efficiency and
The unit is equipped with a power electric
low pressure drops.
control board on the machine and adjustment
Soft air bag F7 filters (flow and recovery)
purposely designed to reduce energy conequipped with a standard differential pressure
sumption. Equipped with a communication
switch, which can be extracted from either
serial port on RS485 with MODBUS Master/
side facilitate their periodic cleaning.
Slave protocol
Fans (intake and flow), Plug fan with back
curved blades with a directly coupled, electronically controlled motor for sizes 07-17 and
with an inverter for sizes 21-24.

Versions
ERSR_T with a sensitive rotary recovery unit
can be installed vertically only with
sizes (ERSR0709TV)
ERSR_H with a hygroscopic rotary recovery
unit can be installed vertically only
with sizes (ERSR0709HV)

Accessories

122

CAP Intake rainproof cover


BDL Flow rainproof cover
FRR Rectangular ange
GAR rectangular anti-vibration joint
HSR Fresh air intake damper with
servocontrol
RSR Circulation damper module
HG4 Flat lters G4
TDP roof protection for basic unit in the

case of outdoor installation


VRC condensate drip tray
VVR Variable speed recovery unit
QP Air quality probe (VOC)
KDP Dehumidication and post-heating
management kit
RBC 3-way valve hot water coil module
RBF 3-way valve cold water coil module
RBE electric coil module

RBP 3-way valve cold water and postheating coil module


MSS silencer bafes module

Features

Qalit the air


Ed

,
&

High-eicienc air circlatin thanks t


lg-ans ith electrnicall cntrlled mtrs r
inerters deending n the sies
 /

 d d
High-eicienc recer nit (80 the energ
the eelled air)







K


State the art electrnic cntrl


E



Accessories compatibility
ERSR

07

09

12

15

17

21

24

CAP07
BDL07
FRR09
GAR07
HSR07
HG407
TDP07
VRC07
VVR07

CAP09
BDL09
FRR09
GAR09
HSR09
HG409
TDP09
VRC09
VVR09

CAP12
BDL12
FRR12
GAR12
HSR12
HSR12
HG412
TDP12
VRC12
VVR12

CAP15
BDL15
FRR15
GAR15
HSR15
RSR15
HG415
TDP15
VRC15
VVR15

CAP17
BDL17
FRR17
GAR17
HSR17
RSR17
HG417
TDP17
VRC17
VVR17

CAP21
BDL21
FRR21
GAR21
HSR21
RSR21
HG421
TDP21
VRC21
VVR21

CAP24
BDL24
FRR24
GAR24
HSR24
RSR24
HG424
TDP24
VRC24
VVR24

RBC07
RBF07
RBE07
RBP07
MSS07

RBC09
RBF09
RBE09
RBP09
MSS09

RBC12
RBF12
RBE12
RBP12
MSS12

RBC15
RBF15
RBE15
RBP15
MSS15

RBC17
RBF17
RBE17
RBP17
MSS17

RBC21
RBF21
RBE21
RBP21
MSS21

RBC24
RBF24
RBE24
RBP24
MSS24

RBC07T
RBF07T
RBE07T
RBP07T
MSS07T

RBC09T
RBF09T
RBE09T
RBP09T
MSS09T

RBC12T
RBF12T
RBE12T
RBP12T
MSS12T

RBC15T
RBF15T
RBE15T
RBP15T
MSS15T

RBC17T
RBF17T
RBE17T
RBP17T
MSS17T

RBC21T
RBF21T
RBE21T
RBP21T
MSS21T

RBC24T
RBF24T
RBE24T
RBP24T
MSS24T

UNIT ACCESSORIES
CAP
BDL
FRR
GAR
HSR
RSR
HG4
TDP
VRC
VVR
QP
KDP
MODULE ACCESSORIES
RBC
RBF
RBE
RBP
MSS
MODULE ACCESSORIES WITH ROOF (for outdoor installations)
RBCT
RBFT
RBET
RBPT
MSST

123

Technical data
Mod. ERSR
Nominal air flow and recovery flow rate
Maximum air flow and recovery static pressure available
Total nominal input power
Maximum air flow and recovery flow rate
Total maximum input power
Total heating capacity recovered
Recovered sens. heating capacity
Winter recovery unit efficiency
Total recovered cooling capacity
Recovered sens. cooling capacity
Summer recovery unit efficiency
Total number of fans

m3/h
Pa
kW
m3/h
kW
kW
kW
%
kW
kW
%
n

07T
1.100
420
0,33
2.000
0,84
10,7
7,4
80
2,8
2,7
80
2

09T
1.950
660
0,48
4.370
2,04
19
13,1
80
4,9
4,7
80
2

12T
3.700
1.100
1,06
5.880
6,09
36
24,9
80
9,3
9
80
2

Sound power level

dB(A)

65,6

67

75,3

Unit power supply


RBC Hot water coil
Heating capacity
Water flow rate
Water side pressure drop
RBF Cold water coil
Total cooling capacity
Sensitive cooling capacity
Water flow rate
Water side pressure drop

V/h/Hz

(1)

76,7

78

78

79

400V/3N/50Hz

(2)
(2)
(2)

kW
m3/h
kPa

9,5
0,8
9

16,9
1,4
8

27,4
2,3
8

46,7
4
7

60,1
5,2
11

95,8
8,4
16

130,4
11,3
20

(3)
(3)
(3)
(3)

kW
kW
m3/h
kPa

10,5
4,1
1,6
15

19,5
7,6
2,9
8

34,7
13,9
6
7

59,8
23,9
10,3
23

80
32
13,7
33

127,4
51
21,9
34

171,3
68,5
29,5
3,2

For the performance of the H version, contact the head office.


Heating
Fresh air ow rate equal to the air expulsion ow rate; Outdoor air temperature (in) -5C 80% r.h.; Room temperature 20C, 50% r.h.
Cooling mode
Fresh air ow rate equal to the air expulsion ow rate; Outdoor air temperature (in) 35C 50% r.h.; Room temperature 26C, 50% r.h.
(1) With nominal air ow rates and useful pressure of 100Pa.
(2) Coil water inlet temperature 70C; Coil inlet-outlet temperature difference 10C; Coil air intake temperature 15C;
Water pressure drops not included with a 3-way valve (standard).
(3) Coil water inlet temperature 7C; Coil inlet-outlet temperature difference 5C; Coil air intake temperature 28C, 75% RH;
Water pressure drops not inclusive with a 3-way valve (standard).
Sound power level of the ow fan not ducted with useful static pressure equivalent to 0 Pa.

124

15T
17T
21T
24T
5.950 7.800 12.200 16.100
1.120 1.040 1.440 1.530
1,69
2,13
3,49
3,85
10.650 14.800 24.750 31.350
8,78
10,18 22,37 30,37
57,9
75,9
118
156
40,1
52,5
82,1
108
80
80
80
80
14,9
19,5
30,5
40,3
14,4
18,9
29,6
39
80
80
80
80
2
2
4
4

Dimensional data (mm)

Hrintal installatin

Vertical installatin nl r ERSR07 and 09

120

C
B

ERSR
Height

07

09

12

15

17

21

24

965

1285

1445

1765

2085

2405

2725

mm

Width

mm

895

1005

1375

1695

1855

2335

2665

Depth

mm

1375

1535

2045

2365

2365

3005

3005

kg

240

340

570

820

1010

1610

1980

Code: SERSRUY.03 /1501

Weight

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

125

03. AIR HANDLING UNIT

The air handling units customized according to different needs of the installer to carry
the best comfort and the best quality in civil commercial and industrial

TUN
Ductable air-conditioning unit

UNIVERSAL CONFIGURATION
VERSION WITH 4-6 ROW COIL
VERSION WITH EXTRACTOR
Features
The air-conditioning units of the TUN series are
intended for civil, commercial and hotel
systems in small to medium sized environments.
They are distinguished by their compactness (a
necessary requisite for false ceiling applications)
and low noise. The wide range of accessories
meets various system requirements
The structure is made of 1.5 mm thick hot
galvanised sheet metal, insulated internally with
a V0 insulation class. The unit is
designed for any flow and/or intake channels to
be connected. The unit can be installed
horizontally or vertically and both are
facilitated by the relative brackets.

Air-filtering relies on standard G2 class filters


in accordance with EN779 (6 mm thick),
positioned on intake.

threaded sleeves for the hydraulic


connections and the air bleeding valve are
supplied. The coils can be rotated on site.

Forward blade double intake centrifugal fans


with a directly coupled motor. The single-phase
230V-50Hz multi-speed motor has three speeds
that are selected via a control.

Post-heating 2-row coils are also available,


made of copper piping with aluminium
louvered fins blocked by mechanical
expansion of the pipes.

Internal condensate drip tray made of 1 mm


thick hot galvanised sheet metal.
4-6 row coils, powered with hot or cold water
and made of copper piping with
aluminium louvered fins blocked by
mechanical expansion of the pipes. The

Choosing the unit


By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific implant
requirements.

Fields configurator:
123
|
Code

45
|
|
|
Size

6
|
Version

Example of a sale code: TUN104P


This is a TUN unit, size 10 with a powered 4-row coil.

128

7
|
|
|
Configuration

Identication:
TUN
Size:
10, 15, 20, 25, 40
Version:
4 - 4 row coil
6 - 6 row coil
Configuration:
P - Powered
X - Extractor

Accessories
M2S Mixing chamber 2 dampers
Section made of galvanised steel sheet with two
air calibration dampers and louvers made of
galvanised sheet steel. 50 mm louver pitch; 8
mm motorised regulation pin made of
galvanised steel.

VRF Return ventilating section with a G4


filter
Ventilating unit equipped with an electronic rev
shifter, contained in a galvanised steel sheet
section with flat filters having a G4
efficiency (EN779).

M3S Mixing chamber 3 dampers


Section made of galvanised steel sheet with
three air calibration dampers and louvers made
of galvanised sheet steel. 50 mm louver pitch; 8
mm motorised regulation pins made of
galvanised steel. It must be coupled with the
VRF accessory.

PMM Plenum with circular flow attachments


1.5 mm Plenum made of hot galvanised sheet
metal. The plenum has multi-diameter
circular plastic fittings (200 mm, 180 mm and
150 mm) for circular pipes to be connected.

FTF Soft bag filter section


Section made of galvanised steel sheet with F6
filtering degree soft bag filters. For
different filtering degrees please contact the
Aermec Sales Technical Dept. It must be
coupled with a powered unit.
B2R 2 row water coil
For 4-pipe systems, positioned internally,
downstream the main coil.
PBE Section with post-heating coil
The electric coil consists of armoured
resistances fitted with a twin safety
thermostat.
SSL Module with silencer baffles
Section made of galvanised steel sheet with
mineral wool silencer baffles covered in a
polyethylene film in order to prevent flaking.
S2Z 2-area damper (70-30%)
Damper made of galvanised steel sheet with
opposite louvers for the external air flow to
blend with the air circulation flow. 50 mm
louver pitch; 8 mm motorised regulation pin
made of galvanised steel.

M2S
M3S
FTF
B2R
PBE
SSL
S2Z
VRF
PMM
TPMC
PMC
SAS
GMD
GAP
FPI
FPF
PX
WMT 05
WMT 10
SIT3

TUN 10
M2S1
M3S1
FTF1
B2R11
PBE2
SSL1
S2Z1
VRF1
PMM1
TMPC1
PMC1
SAS1
GMD1
GAP1
FPI11
FPF1

FPI G4 filters for lower intake


FPF G4 filters
PX Control panel with only the switch-over

WMT 05 Electro-mechanical thermostat


For fan coils installed in 2-pipe systems. The
panel must be installed on the wall and
protected electrically with an internal fuse. It
has the following functions: on / off switch;
cursor to select the heating / cooling modes
(manual season change); cursor to select the fan
TPMC Plenum of delivery
speed (high, medium and low);
Plenum to be used for the connection with cir- temperature selector (+5C to 30C)
cular canals. Made of galvanized steel with
insulating mat with circular nozzles Three sec- WMT10 Control panel
tions closed. It can be used as a plenum, both For fan coils installed on the wall. Controls the
as a plenum aspiration with circular channels.
fan coil operation according to the set mode.
The panel must be wall mounted; it is to be
PMC Closed flow plenum
used in 4-pipe and 2-pipe systems and systems
1.5 mm Plenum made of hot galvanised sheet
with 2-pipes with resistance, with the possibility
metal. The plenum allows the flow to turn 90.
of connecting two ON - OFF type valves for the
The installer must make the flow
cut-off of the coil supply water. The panel is
aperture.
protected electrically by an internal fuse. The
control has the following functions:
SAS Intake damper
1) cursor to select the cooling or heating mode;
Air calibration damper with louvers made of
2) manual season change;
galvanised sheet steel. 50 mm louver pitch; 8
3) manual selection of the fan speed;
mm motorised regulation pin made of
4) selection of the desired room temperature (+
galvanised steel.
10C to 30C);
5) 2-pipe system management;
GMD Flow grid with adjustable louvers
6) 4-pipe system management;
Grid with double row adjustable louvers for air
7) 2-pipe system management (cooling) +
to be introduced in the relative room. It can be
electrical resistance (heating);
installed directly on to the appliance by
8) thermostatic ventilation;
removing the flanges or on to the wall.
9) continuous ventilation;
10) continuous ventilation in cooling mode and
GAP Intake grid
thermostatic in heating mode.
With louvers tilted at 45; it can be installed
directly on to the appliance by removing the
flanges or on to the wall.

TUN 15
M2S2
M3S2
FTF2
B2R21
PBE3
SSL2
S2Z2
VRF3
PMM2
TMPC2
PMC2
SAS2
GMD2
GAP2
FPI12
FPF2

(1)
(1)

Accessories compatibility
TUN 20
M2S3
M3S3
FTF3
B2R31
PBE4
SSL3
S2Z3
VRF4
PMM3
TMPC3
PMC3
SAS3
GMD3
GAP3
FPI13
FPF3

(1)
(1)

TUN 25
M2S4
M3S4
FTF4
B2R41
PBE5
SSL4
S2Z4
VRF5
PMM4
TMPC4
PMC4
SAS4
GMD4
GAP4
FPI14
FPF4

(1)
(1)

TUN 40
M2S4
M3S4
FTF4
B2R41
PBE6
SSL4
S2Z4
VRF6
PMM4
TMPC4
PMC4
SAS4
GMD4
GAP4
FPI14
FPF4
(2)
(2)
(2)

TUN 40P
M2S5
M3S5
FTF5
B2R51
PBE7
SSL5
S2Z5
VRF7
PMM5
TMPC5
PMC5
SAS5
GMD5
GAP5
FPI15
FPF5
(2)
(2)
(2)

(1) SIT3 is to be used and the 2A fuse is to be replaced with a 4A fuse


(2) Install a relay, one per speed

129

Technical data
10

15

20

25

40

10P

40P

kW
kW
kW
kW

4,7
3,6
6,2
4,4

9,3
6,6
11,1
7,6

12,5
8,7
14,1
9,8

16,5
11,4
18,5
12,7

23,3
16,3
26,6
18,5

4,7
3,6
6,2
4,4

26,4
18,2
29,4
20,1

l/h
l/h

804
1072

1599
1910

2141
2420

2832
3184

4002
4572

804
1072

4536
5051

kPa
kPa
kW
kW
kW
kW
kW

3
9

16
34

33
20

33
20

60
37

3
9

56
28

11,2
12,5
5,5
6,1

19
21,1
9,3
10,5

24,9
27,5
12,1
13,6

32,3
35,4
16
17,6

46,7
52,2
25,9
28,9

16,6
18,5
6,4
7,2

51,1
56,1
30,8
34,8

l/h
l/h

978
1097

1663
1849

2183
2410

2831
3101

4089
4573

978
1097

4475
4909

kPa
kPa
kW
l/h
kPa

4
7
7
609
4

13
24
11,7
1026
7

24
15
15,3
1339
7

24
14
20,5
1792
10

46
28
27,9
2444
17

4
7
7
609
4

41
20
31,8
2786
10

kW
n

4
2

8
2

10
2

12
2
400V/3/50Hz

20
2

6
2

20
2

900
110
357
1,6
2

1500
150
713
3,1
2

2000
170
886
3,9
4

2500
150
874
3,8
4
230V/1/50Hz

4000
120
1771
7,7
4

900
330
713
3,1
2

4000
220
1771
7,7
4

G2/G4
F6

G2/G4
F6

G2/G4
F6

G2/G4
F6

G2/G4
F6

G2/G4
F6

G2/G4
F6

dB(A)

68

72

77

78

79

71

80

1
"

1
"

1
"

1
"

1
"

1
"

1
"

Cooling capacity with:


4-row coil (1)
6-row coil

(1)

Water ow rate
4-row coil
6-row coil
Pressure drop
4-row coil (2)
6-row coil (2)
Heating capacity with
4-row coil (2)
6-row coil (2)
4-row coil
6-row coil
Water ow rate
4-row coil
6-row coil
Pressure drop
4-row coil
6-row coil
Heating capacity 2-row water coil
Water ow rate
Pressure drop
Electrial coil:
Electric coil capacity
No. of stages of the electric coil
Power supply
fan:
Air ow rate (3)
Static pressure
Fan power supply
Fan input current
Poles
Power supply
Filters:
Efciency of at lters (4) std/opt
Efciency of bag lters
Sound data:
Sound power
Hydraulic connections:
Main coil collectors
Additional coil

total
sensible
total
sensible

total
total
total
total

m3/h
Pa
W
A
n

STD/OPT

(1) Temperature of incoming air


Water temperature inlet
Water temperature outlet

27C b.s.|19C b.u.


7C
12C

(2) Temperature of incoming air


Water temperature inlet
Water temperature outlet

20C
70C
60C

(3) At nominal flow rate with 4-row coil


(4) In compliance with

130

EN 779

Dimensional data (mm)

C
B

TUN HORIZONTAL INSTALLATION WITH EXTRACTOR


FRONT VIEW

Mod. TUN
10
10P
15
DIMENSIONS OF A HORIZONTAL INSTALLATION AND "EXTRACTOR" CONFIGURATION
Height (A)
mm
300
300
300
Width (B)
mm
700
700
1050
Length (C)
mm
700
700
700
Connection projection
mm
82
82
82
Number of fans
n
1
2
2

kg
kg

10
33
35

10P
37
38

15
47
49

25

40

40P

390
1050
850
82
1

390
1475
850
82
1

390
1475
850
82
2

390
2100
1000
82
2

20
59
61

25
88
92

40
88
92

40P
108
108

Cod.: STUNUY.10 / 1406

UNIT NET WEIGHTS


4-row coil
6-row coil

20

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

131

TS

Air handling units with cooling capacity from 4.85 up to 24.8 kW

TSMX
TS
TSBA
TSPM

Characteristics

Compact unit for horizontal installation


gal fans
sation
Structure made of Aluzink sheet steel and Three-speed electrical motor with running Large choice of distance commands
internally covered with sheets of polyethylene
capacitor permanently activated and internal Wide range of accessories to meet varying
and polyester to obtain improved thermal and
thermal protection
needs (class G3 air filter, post-heating coils,
acoustic insulation
NOTE: Possibility to also have the engine
plenum suction assembly, mixer section, suc Condensate drip tray in stainless steel AISI
with five speed.
tion grille, delivery flanges with circular
304 with insulation
Transmission system relay card for each speed
outlets or rectangular outlet)
Coils with aluminium fins and copper pipes
(excluding the models TS13 and TS16)
Statically and dynamically balanced centrifu- Useful static pressure available for any canali-

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system
requirements.
Code:
Field configurer:
TS
12
3
4
|
|
|
Size:
Code
|
|
1, 2, 3, 4, 5, 6, 7
|
Size
|
Coil:
|
|
Row coil
3 - 3-row coil
|
|
|
TS
1234567
346
4 - 4-row coil
6 - 6-row coil

Models available:
Standard with 3 speed electrical motor
TS 13 - 16 - 23 - 34 - 36 - 43 - 46 - 53 - 56 - 63 - 74 - 76
with 5 speed electrical motor
TS 135V - 165V - 235V - 345V - 365V - 435V - 465V - 535V - 565V - 635V - 745V - 765V

Accessories
TSBA: 2-row coil for post-heating, contained in
which the TSGA grille can be applied
the connector (W) of the FMT21 panel. Two
a delivery installation plenum
TSPM: Delivery plenum to be connected to the
SWA probes can be connected simultaneously
TSFA: Class G3 air filter
circular channels (with 2, 3 or 4 circular, 200
to the FMT21 panel.
TSFM: Delivery flange with rectangular section
mm flanges).
Control panels:the characteristics of the control
TSGA: Horizontal suction grille with fixed fins SWA: External probe accessory SWA (length L =
panels are described on the appropriate card.
to produce suction from below together with
6m). It detects the temperature of the room air if
the TSPA accessory
connected to the connector (A) of the FMT21
TSMX: Section that mixes the recirculating air
panel. The room air temperature probe, incorand the external air. Calibration of the mix via
porated in the panel, is automatically disabled.
the damper, motorisation is possible
It detects the temperature of the water in the
TSPA: Plenum with suction from below, to
system for ventilation consent if connected to
TSPA

TSMX

TSFA

TS

TSRD
TSRS

TSBA

TSFM

TSPM

TSGA

AIR

AIR
AIR

132

Technical data
Model

U.M.

Cooling capacity
Sensible cooling capacity
Water side pressure drop
Water flow rate
Heating capacity (70C)
Water side pressure drop
Water flow rate
Nominal air flow rate
Useful static pressure
TSFA filter pressure drop
Coil rows
Coil water connections
Maximum water temperature
Ventilation speed number
Motors
Fans
Ventilation speed number
Motors
Motor maximum power
Maximum input current
Sound pressure level
Power supply

kW
kW
kPa
l/h
kW
kPa
l/h
m3/h
Pa
Pa
n.

(1)
(2)

TS 13
TS 16
TS 23
TS 34
TS 36
TS 43
TS 46
TS 53
TS 56
TS 63
TS 74
TS 76
TS135V TS165V TS235V TS345V TS365V TS435V TS465V TS535V TS565V TS635V TS745V TS765V
4.85
5.80
7.9
9.6
10.5
11.1
13.3
13.9
16.5
16.6
21.9
24.8
3.75
4.45
6.4
7.6
8.3
8.95
10.7
9.8
11.7
13.1
17.8
20.1
21
9
24
24
16
23
17
32
27
26
28
26
830
1000
1360
1650
1810
1910
2290
2390
2840
2860
3770
4270
9.80
12.58
15.50
19.70
21.52
21.60
27.49
25.90
32.89
35.50
46.30
52.06
12
8
17
20
13
17
13
21
21
20
23
21
840
1080
1330
1690
1850
1860
2360
2230
2830
3050
3980
4480
930
930
1500
1600
1600
2050
2050
2400
2400
3600
4200
4200
90
55
100
85
45
115
75
105
70
120
115
75
13
13
11
12
12
13
13
11
11
16
25
25
3
6
3
4
6
3
6
3
6
3
4
6
G 3/4"
G 1"
G 3/4"
G 3/4"
G 1"
G 3/4"
G 1"
G 3/4"
G 1"
G 1"
G 1"
G 1"
120
120
120
120
120
120
120
120
120
120
120
120

bar

15

15

15

15

15

15

n.

1
3
1
225
1
50

1
3
1
225
1
50

2
3
1
345
1,9
51

2
3
1
345
1,9
52

2
3
1
345
1,9
52

2
3
1
550
2,6
55

n.
W
A
dB(A)
V/ph/Hz

15

15

15

15

15

15

2
2
3
3
1
1
550
550
2,6
2,6
55
55
230V/1/50Hz

2
3
1
550
2,6
55

2
3
1
600
3,9
58

2
3
1
830
5,5
58

2
3
1
830
5,5
58

Cooling
Room air temperature 27C b.s./19C b.u.; Water inlet temperature 7C; T water 5C.
Heating (70C)
Room air temperature 20C b.s.; Water inlet temperature 70C; T water 10C.
(1) Rated capacity (maximum speed) without air filter
(2) Air filter (TSFA accessory) at rated capacity

TS

13 - 16
23
34 - 36
43 - 46
53 - 56
63
74 - 76

TSBAx
10
20/30
40
50
60/70

TSFAx
10
20/30
40
50
60/70

TSFMx
10
20/30
40
50
60/70

*
*
*
*
*
*
*

*
*
*
*
*
*
*

*
*
*
*
*
*
*

Compatibility of accessories
TSGAx
TSMXx
TSPAx
10
10
10
20/40
20/30
20/30
40
40
50/60/70
50
50
60/70
60/70
*
*
*
*
*
*
*

*
*
*
*
*
*
*

TSPMx
10
20/30
40
50
60/70

FMT10
10
21

PXAE

WMT
05
10
06

SWA**

*
*
*
*
*
*
*

(x 1-2)
(x 1-2)
(x 1-2)
(x 1-2)
(x 1-2)
(x 1-2)
(x 1-2)

*
*
*
*
*
*
*

* = The code of these accessories is obtained by substituting the letter x with the number indicating the corresponding size of the unit
** = SWA accessories are matched with FMT21 control panels.

Height (A)
Width (B)
Depth (C)
Weight

[mm]
[mm]
[mm]
[kg]

TS13
296
645
520
25

TS16
296
645
520
27

TS23
296
1000
520
35

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

TS34
296
1000
520
38

TS36
296
1000
520
42

TS43
325
1100
600
42

TS46
325
1100
600
46

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

TS53
325
1345
600
48

TS56
325
1345
600
52

TS63
375
1345
600
56

TS74
375
1345
600
61

Cod.: STS1UY.04 / 1311

Dimensions (mm)

TS76
375
1345
600
67,5

133

TDA

Air handling units


Air flow rate from 800 to 3,500 cu.m/h

HORIZONTAL OR VERTICAL INSTALLATION


VERSION WITH 3-4 ROW WATER-TYPE COIL
VERSION WITH 2-ROW DIRECT EXPANSION COIL
VERSION WITH EXTRACTOR

Characteristics
The conditioning units in the TDA range have
been designed for small and medium sized
rooms in civil, commercial and hotel type
systems.
The units are designed to guarantee high head
levels and are suitable for both vertical and
horizontal installation, to ensure greater
versatility of use. The outstanding aesthetic
finish of the product makes it perfect for
installation in box rooms, bathrooms,
suspended ceilings or in the room itself.
The wide range of sizes and accessories
available means it's easy to choose the best
model for the specific requirements.

Structure with hot galvanised steel sandwich


panels, 15mm thick, with interposed
polyurethane foam (density 40kg/m3). The
delivery and suction panels are equipped with
flanges for the collets to any air channels and
can be moved to create different air flow
configurations. The horizontal or vertical fixing
to the walls of the unit is made possible by the
appropriate brackets.
New centrifugal fans with high head levels,
double suction, forward blades and directly
coupled motor. The single-phase 230V-50Hz
motor is multi-speed (of which three speeds can
be selected).

Condensated collection basin in galvanised


steel, suitable for both vertical and horizontal
installation.
Coils with 3 rows, that can be fed with hot or
refrigerated water. Made of copper pipes with
aluminium finning held in place by the
mechanical expansion of the pipes. They are
equipped with threaded sleeves for the
plumbing connections and the air breather
valve. The coils can be rotated on site.
A 2-row, direct expansion coil is also
available. It is made of copper pipes with
aluminium finning held in place by the
mechanical expansion of the pipes.

Accessories
FAF filter G4 on intake
Contained in the special housing, it is made of
synthetic fibre and pleated geometry; the
U-shaped frame is in galvanised sheet metal
with two galvanised wire support nets
SM Mixing chamber with G4 filter and dampers
Galvanised steel housing complete with two air
adjustment dampers with opposed fins in galvanised steel. The housing comes complete with a
synthetic fibre filter (efficiency class G4, in
accordance with standard EN779).
SR Intake damper
Consisting of a frame with galvanised steel ribbed fins. The fins are moved by nylon toothed
wheels.
GM Delivery grille
Grille with double row of adjustable fins to
introduce air into the room.

FAF
SM
SR
GM
GA
CMA
BP

134

TDA09
FAF1
SM1
SR1
GM5
GA5
CMA5
BP1

GA Suction grille
the delivery panel with rectangular flange, using
With tilted fins fixed at 45; can be installed
the same 4 self-threading screws.
directly on the device (by removing the flange) Control panels:
or on the wall.
PX with selector only
CMA Outer casing for grille
WMT05 Electromechanical thermostat.
BP One-row water-type post-heating coil
WMT10 control panel
applied outside the unit
Contained in a special, thermally-insulated housing, it is installed on the air delivery flange
only and consists of a 1-row turbo-type coil.
BR Electric post-heating coil applied outside
the unit
The machines can be fitted with the electric coil
accessory of suitable capacity. It is installed
downstream of the finned coil only.
PM Delivery plenum with circular start-up
Sandwich panel in hot galvanised steel, with
interposed polyurethane foam (40kg/m3). The
panel is 15mm thick. It is installed in place of

Compatibility of accessories
TDA15
TDA21
TDA 28
FAF2
FAF3
FAF4
SM2
SM3
SM4
SR2
SR3
SR4
GM6
GM7
GM8
GA6
GA7
GA8
CMA6
CMA7
CMA8
BP2
BP3
BP4

TDA37
FAF4
SM5
SR4
GM8
GA8
CMA8
BP5

BR
PM
PX
WMT05
WMT10

TDA09
BR1
PM1

Compatibility of accessories
TDA15
TDA21
TDA 28
BR2
BR3
BR4
PM2
PM3
PM4

(1)
(1)
(1)
(1)
(1)
(1)

TDA 37
BR5
PM4
(2)
(2)
(2)

(1) Envision the use of SIT and the replacement of the AA fuse with one AA fuse
(2) Envisions return relay, one per speed

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system
requirements.
Code:
Field configurer:
TDA
Size:
123
46
6
|
|
|
09, 15, 21, 28, 37
Code
|
Version
Version:
|
3 - 3-row water coil
Size
4 - 4-row water coil
E - 2-row direct expansion coil
X - Extractor (without coil)

Technical data
Mod. TDA

Nominal air ow rate


Useful static pressure (1)
total
sensible
total
sensibile
totale
sensibile

Cooling capacity with 3-row coil (2)


Cooling capacity with 4-row coil (2)
Cooling capacity with
R-407C coil (3)
Heating capacity with 3-row coil (4)
Heating capacity with 4-row coil (4)
Heating coil capacity for 4-pipe systems (4)
Heating capacity with 3-row coil (5)
Heating capacity with 4-row coil (5)
Heating capacity with coil for 4-pipe systems (5)
Electric coil capacity
Electric coil power supply
Fans
Motors
Total fan input power
Fan input current
Fan power supply
Filter efciency (6)
Sound power level (7)
Connections
Water battery collectors
Direct expansion liquid coil pipes
Direct expansion gas coil pipes
Condensate discharge

9
800
222
277
4,90
3,50
6,10
4,30
5,10
3,50
10,40
12,10
5,20
5,10
6,00
2,50
4

15
1400
389
330
7,40
5,60
9,70
6,90
7,50
5,20
16,60
19,90
8,80
8,10
9,80
4,30
6

1
1
0,357
1,6

2
2
0,713
3,1

dB(A)

G4
62

G4
63

21
2000
556
227
11,10
8,20
13,10
9,40
10,70
7,40
24,20
27,30
12,60
11,90
13,40
6,00
8
230V~/50Hz
2
2
0,736
3,2
230V~/50Hz
G4
70

mm
i mm
u
mm

1
10
18
3/8

1
10
22
3/8

1
12
22
1/2

m3/h
l/s
Pa
kW
kW
kW
kW
kW
kW
kW
kW
kW
KW
KW
KW
KW
n
kW
A

(1) at nominal flow rate with 3-row coil


(2) Incoming air temperature 27C d.b. 19C w.b.; water temperature (In-Out)
7C-12C
(3) Incoming air temperature 27C d.b. 19C w.b.; average evap. temp. 7C

(4)
(5)
(6)
(7)

28
2700
750
150
14,70
10,90
18,40
12,50
14,10
9,90
32,10
36,80
16,40
15,70
18,20
7,80
10

37
3500
972
240
17,90
13,70
22,30
15,20
16,70
12,40
41,20
45,40
20,90
20,10
22,30
10,00
12

1
1
0,874
3,8

2
2
1,771
7,7

G4
72

G4
73

1
16
28
1/2

1
16
28
1/2

Incoming air temperature 20C; water temperature (In-Out) 70C-60C


Incoming air temperature 20C; water temperature (In-Out) 45C-40C
In accordance with standard EN 779
In accordance with standard UNI EN ISO 9614

TDA
Height (B)
Width (C)
Lenght (A)
Net weight *

mm
mm
mm
kg

9
300
920
630
42

15
320
1000
670
53,00

21
320
1400
670
71,00

28
380
1400
790
88,00

37
380
1400
790
91,00

(*) with 4-row coil

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293577
www.aermec.com

135

Cod.: STDAUY.01 / 0911

Dimensions (mm)

TA

Air handling unit with 4 row cooling coil from 4.5 up to 32 kW


5.5 a 40 kW 6 row coil
heating efficiency with 4 row coil from 14.0 up to 78.0 kW
15.5 a 87.5 kW 6 row coil

HORIZONTAL OR VERTICAL CONFIGURATION


VERSION WITH 4-6 ROWS WATER COIL
VERSION WITH 4 ROW EXPANSION COIL USING R410A
VERSION WITH EXTRACTOR

Features
The air conditioning units in the TA range are
destined to civil, commercial and hotel systems, for applications in small to medium
sized environments.
The units in the TA range are characterised for
their compactness (indispensable requisite for
typical suspended-ceiling applications), the
low noise and high useful static pressure.
The great availability of accessories (e.g. bag filters and the mixing chambers with 3 dampers) allows to satisfy the most varied plant
requirements
Structure realised with sandwich panels with
thickness of 15 mm with polyurethane (density 40 kg/m3). The intake panel is equipped
with a flange for fitting to any air channels.

Horizontal or vertical fixing to a wall is made


sleeves are supplied for the hydraulic attacheasy by the brackets.
ments and the air vent valve.
Filtration of the air entrusted to class G4 filThe possibility to rotate the coils on site is
ters in compliance with EN779 (thickness
envisioned.
50mm) as per standard positioned at intake.
Also available are coils with 4 rows with
Fans double intake centrifugal with forward
direct expansion operating with R410A fluid
blades and directly coupled motor.
and post-heating coils with 1 and 2 rows realThe 230V-50Hz single-phase motor has many
ised in copper piping with aluminium louvers
speeds, of which three can be selected via the
blocked via mechanical expansion of the
control panel.
pipes.
Condensate drip tray interior isolated in aluminium alloy.
Coils with 4, 6 rows that can be fed with hot
or cooled water realised in coil in copper
piping with aluminium louvers blocked via
mechanical expansion of the pipes. Threaded

Choosing the unit


By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific implant
requirements.

Fields configurator:
12
|
Code

34
|
|
|
Size

5
|
Configuration

Code:
TA
Size:
09, 11, 15, 19, 24, 33, 40, 50
Configuration:
H - Horizontal
V - Vertical
X - Extractor
Example of a sale code: TA09H4
This is a TA unit, size 09 horizontal with 4 row coil.

136

6
|
|
|
Version
Version:
4 - Coil with 4 rows
6 - Coil with 6 rows
E - R410A coil with direct expansion 4 left rows

Accessories
M2S 2 damper mixing chamber
Louver pitch 50 mm; regulation pin in galva- WMT 05 Electro-mechanical thermostat
Galvanised sheet steel section complete with
nised steel with diameter 8 mm mechanisaFor fan coils installed in 2 pipe systems The
two air calibration dampers with galvanised
tion.
panel must be installed on the wall and prosheet steel louvers.
tected electrically by an internal fuse.
Louver pitch 50 mm; regulation pin in galva- VRF Recovery fan section with G4 filter
Has the following functions: on/off switch;
nised steel with diameter 8 mm mechanisaFan unit, equipped with electronic varistor of
cursor for the selection of heating/cooling
tion.
the number of revs. contained in a section in
modes (manual season change); cursor for the
galvanised sheet steel equipped with flat filselection of fan speed (high, medium and
M3S 3 damper mixing chamber
ters with G4 efficiency (EN779).
low); temperature selector switch
Galvanised sheet steel section complete with
(+5C30C)
three air calibration dampers and galvanised PMM Plenum with multiple circular flows
sheet steel louvers.
Plenum equipped with sandwich panelling WMT10 Control panel
Louver pitch 50 mm; regulation pins in galvawith thickness of 15 mm in galvanised steel
For can coils with wall installation.
nised steel with diameter 8 mm mechanisawith polyurethane insulation. The plenum is
Control functioning of the fan coil depending
tion.
supplied with multi-diameter circular attachon the mode set.
Va must be coupled with the VRF accessory
ments (200 mm, 180 mm and 150 mm) in
The panel must be mounted on the wall, it is
plastic to allow the connection of circular
used on 4 pipe and 2 pipe and 2 pipe with
FTF Soft bag filters section
conduits.
resistance systems, with the possibility of
Galvanised sheet steel section complete with
connecting two On - Off type valves for the
soft bag filters with F6 filtration level.
PMC Closed flow plenum
cut-off of the coil supply water. The panel is
For different filtrations, contact the AERMEC
Plenum closed equipped with sandwich panprotected electrically by an internal fuse.
technical-sales dept.
elling with thickness of 15 mm in galvanised
The control has the following functions: cursteel with polyurethane insulation.
sor for the selection of the cooling or heating
B1R 1 row water coil
The plenum allows to turn the flow by 90.
functioning mode;
For 4 pipe systems, positioned internally,
The opening of the flow hole is the installer's
manual season change;
downstream from the main coil.
responsibility.
manual selection of the fan speed
Threaded sleeves are supplied for the hydrauselection of the desired environment temperature (+10CA30CA);
lic attachments and the air vent valve.
SAS Intake damper
2 pipe systems management;
Air calibration damper with galvanised sheet
4 pipe systems management;
B2R 2 row water coil
steel louvers.
2 pipe systems management (cooling) +
For 4 pipe systems, positioned internally,
Louver pitch 50 mm; regulation pin in galvaelectrical resistance (heating);
downstream from the main coil.
nised steel with diameter 8 mm mechanisathermostat ventilation;
Threaded sleeves are supplied for the hydraution.
continuous ventilation;
lic attachments and the air vent valve.
continuous ventilation in cooling mode and
GMD Flow grid with moveable louvers
thermostat ventilation in heating mode.
PBE Section with post-heating coil
Grid with double order of moveable louvers
The electric coil is made up from armoured
for the introduction of air into the room to be
resistances equipped with double safety therconditioned.
mostat.
It can be installed directly onto the appliance
by removing the flanges or on the wall.
SSL Module with seven silencers
Galvanised sheet steel section complete with GAP Intake grid
seven silencers in mineral wool covered with
With fixed louvers inclined by 45; can be
a polyethylene film to prevent exfoliation.
installed directly onto the appliance by
removing the flanges or on the wall.
S2Z Damper with 2 areas (70-30%)
Galvanised sheet steel damper with opposite FPI G4 flange filters
louvers for the mixture of the external air flow PX Switch-over only control panel
and the flow of recirculation air.

M2S
M3S
FTF
B1R
B2R
PBE
SSL
S2Z
VRF
PMM
PMC
SAS
GMD
GAP
FPI
PX
WMT 05
WMT 10

TA 09
M2S1
M3S1
FTF1
B1R1
B2R1
PBE1
SSL1
S2Z1
VRF1
PMM1
PMC1
SAS1
GMD1
GAP1
FPI1

TA 11
M2S1
M3S1
FTF1
B1R1
B2R1
PBE2
SSL1
S2Z1
VRF2
PMM1
PMC1
SAS1
GMD1
GAP1
FPI1

(1)
(1)

Accessories compatibility
TA 15
TA 19
TA 24
M2S2
M2S3
M2S4
M3S2
M3S3
M3S4
FTF2
FTF3
FTF4
B1R2
B1R3
B1R4
B2R2
B2R3
B2R4
PBE3
PBE4
PBE5
SSL2
SSL3
SSL4
S2Z2
S2Z3
S2Z4
VRF3
VRF4
VRF5
PMM2
PMM3
PMM4
PMC2
PMC3
PMC4
SAS2
SAS3
SAS4
GMD2
GMD3
GMD4
GAP2
GAP3
GAP4
FPI2
FPI3
FPI4

(1)
(1)
(1)
(1)
(1)
(1)

TA 33
M2S4
M3S4
FTF4
B1R4
B2R4
PBE6
SSL4
S2Z4
VRF6
PMM4
PMC4
SAS4
GMD4
GAP4
FPI4
(2)
(2)
(2)

TA 40
M2S5
M3S5
FTF5
B1R5
B2R5
PBE7
SSL5
S2Z5
VRF7
PMM5
PMC5
SAS5
GMD5
GAP5
FPI5
(2)
(2)
(2)

TA 50
M2S5
M3S5
FTF5
B1R5
B2R5
PBE8
SSL5
S2Z5
VRF8
PMM5
PMC5
SAS5
GMD5
GAP5
FPI5
(2)
(2)
(2)

(1) Envision the use of SIT and the replacement of the 2A fuse with one 4A fuse
(2) Envisions return relay, one per speed

137

Technical data
Mod. TA
Nominal air ow rate
Useful static pressure (1)
Cooling capacity with 4 row coil (2)
Cooling capacity with 6 row coil (2)
Cooling capacity with 4 row coil with direct exp.R-410A (3)

total
sensible
total
sensible
total
sensible

Heating capacity with 4 row coil (4)


Heating capacity with 6 row coil (4)
1 row water coil heating capacity for 4 row pipes (8)
2 row water coil heating capacity for 4 row pipes (8)
Heating capacity with 4 row coil (5)
Heating capacity with 6 row coili (5)
1 row water coil heating capacity for 4 row pipes (5)
2 row water coil heating capacity for 4 row pipes (5)
Electric coil capacity
Number of electric coil stages
Electric coil power supply
Fans
Motors
Fans total input power
Fans input current
Fans power supply
Poles
Flat lters capacity (6)
Soft bag lters efciency (6)
Sound power level (7)
Connections
Coils collectors
Direct expansion coil pipes
Condensate Drain

(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)

IN
OUT

m3/h
l/s
Pa
kW
kW
kW
kW
kW
kW
kW
kW
kW
KW
KW
KW
KW
KW
KW
n

9
900
250
110
4.7
3.5
5.4
3.9
6.6
4.2
14.2
15.7
5.2
8.4
5.5
6.1
2.2
3.6
4
2

11
1100
306
277
5.7
4.2
6.7
4.7
7.3
4.7
16.6
18.5
5.7
9.5
6.4
7.2
2.4
4.1
6
2

15
1500
417
249
8.7
6.2
11.7
7.5
11.0
7.0
23.9
26.6
9.2
14.2
9.3
10.5
4.0
6.2
8
2

n
n
W
A

1
1
357
1,6

2
2
713
3,1

2
2
713
3,1

dB(A)

2
G4
F6
63

2
G4
F6
66

2
G4
F6
67

inc.
mm.
mm.
inc.

1"
16
22

1"
16
22

1"
16
22

At nominal capacity with 4 row coil


Entry air temperature 27C d.b. 19C w.b.; water temperature (Ent-Ex) 7C - 12C
Entry air temperature 27C d.b. 19C w.b.; medium evap. temperature 2C
Entry air temperature 10C; Water temperature (Ent-Ex) 70C - 60C
Entry air temperature 20C; Water temperature (Ent-Ex) 45C - 40C
Inc with the EN 779 Standard
Sound power in compliance with UNIX EN ISO 9614-2 Standards
Entry air temperature 15C; Water temperature (Sent-Ex) 70C - 60C

138

19
24
1900 2400
528
667
223
165
12.4
17.3
8.3
11.2
15.5
20.6
9.8
12.8
14.2
19.2
9.1
12.1
30.8
40.6
34.2
44.3
11.4
15.9
17.9
24.3
12.1
16.0
13.6
17.6
4.9
6.9
7.8
10.6
10
12
2
2
400V-3-50Hz
1
1
1
1
886
874
3,9
3,8
230V-1-50Hz
4
4
G4
G4
F6
F6
72
74
1"
16
22

1"
16
22

33
3300
917
215
21.7
14.3
26.3
16.6
23.0
14.8
52.2
58.0
18.3
29.9
20.6
23.0
7.9
13.0
16
2

40
4000
1111
220
27.2
18.0
33.5
20.9
30.5
19.4
65.8
72.6
25.2
38.9
25.9
28.9
10.9
16.9
20
2

50
5000
1389
163
31.8
21.3
39.6
25.0
34.5
22.3
78.3
87.5
27.7
44.9
30.8
34.8
12.0
19.5
24
2

2
2
1771
7,7

2
2
1771
7,7

2
2
2852
12,4

4
G4
F6
75

4
G4
F6
76

4
G4
F6
79

1"
16
22

1"
22
28

1"
22
28

Dimensional data (mm)

A
D

TA HORIZONTAL INSTALLATION AND WITH EXTRACTOR

Mod. TA
9
11
HORIZONTAL CONFIGURATION DIMENSIONS AND "EXTRACTOR" CONFIGURATION
Height (B)
mm
300
300
Width (C)
mm
700
700
Lenght (A)
mm
700
700
Connections projection (D)
mm
82
82
Number of fans
n
1
2

15

19

24

33

40

50

300
1050
700
82
2

390
1050
850
82
1

390
1475
850
82
1

390
1475
850
82
2

390
2100
1000
82
2

390
2100
1000
82
2

11

15

19

24

33

40

50

840
300
700

840
300
700

840
300
1050

1090
390
1050

1090
390
1475

1090
390
1475

1090
390
2099

1090
390
2099

732
655
70
1

732
655
70
2

1082
655
70
2

1082
905
70
1

1507
905
70
1

1507
905
70
2

2131
905
70
2

2131
905
70
2

9
28
30

11
33
35

15
45
47

19
60
62

24
78
81

33
86
89

40
135
139

50
140
144

F
36,5

F
A

Mod. TA
VERTICAL CONFIGURATION DIMENSIONS
Height (B)
Width (C)
Lenght (A)
Fixing points
(D)
(E)
(F)
Number of fans

mm
mm
mm
mm
mm
mm
mm
n

UNIT NET WEIGHTS


4 row coil
6 row coil
Extractor

mm
kg
kg

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

139

Cod.: STAUY.00 / 0910

TA VERTICAL INSTALLATION

TN

Air conditioning unit


Air flow from 2300 to 23000 m3/h.

The TN units are destined to commercial and industrial plants for medium size rooms.
The series consists of eight sizes with nominal air ow from 3000 m3/h to 23000 m3/h and allows the ltration, heating and / or cooling treatments.
The performances are ensured by high efciency heat exchangers and high pressure fans coupled to the motor by variable pulley and belt.
The compactness, low noise level, and the wide range of accessories gives the TN series a huge versatility in order to adapt to customer requirements: in
addition to the possibility of transforming the model from horizontal to vertical and the contrary too, it has been chosen to add a enhanced conguration
to ensure a higher pressure of the fan.

Features
VERSIONS:
FANS:
8 available sizes in vertical configuration with Fans are centrifugal type, double suction and
the possibility to change them in horizontal
forward blades with high performances.
version.
Enhanced configuration to ensure a higher
MOTORS:
pressure of the fan.
The installed electrical motors are asynchronous three-phase, with closed frame and outFRAME:
side ventilation, comply with the regulations
The frame is made of aluminum profiles with
IEC, CEI, UNEL (protection class IP55), single
sandwich panels made of galvanized steel
speed (4 poles).
inside and prepainted galvanized steel RAL
9002 outside with polyurethane insulation
TRANSMISSIONS:
(density 40 kg / m) and thickness of 25 mm.
Pulleys are with variable diameter to better
Both panels of the base unit and panels of the
set of the fan to the installation.
plenum are provided with pre-cuts which
Belts can be SPA or SPB type.
allow to make them compatible with the inteThey are supplied with conical clamping ,
gration of accessories.
Taperlock type and are statically and dynaThe fastening of the panels through profile
mically balanced.
block panel, ensures a perfect seal between
panel and frame, and an extreme ease of
WATER HEAT EXCHANGERS:
assembly/ disassembly of the panels.
The 3 ways corner joint is made of nylon The water heat exchangers are made of copper pipes and aluminum fins, blocked by
reinforced with glass fibers.
mechanical expansion of the tubes; the main
The condensate drain pan, in galvanized
coil can be 4 or 6 rows (hot or cold) and 2, 3
steel, is provided with threaded drain conor 4 rows the secondary one (only hot ).
nection on both sides and it is suitable for
The filtration is carried out by 50 mm thick
both horizontal and vertical installation of the
synthetic filters with G4 efficiency class
unit.
(according to EN 779) placed on suction side.

140

FILTERS
These filters are easily removable to facilitate
their maintenance and cleaning; they are placed on guides of the main coils section.
The removal of filters can be done pulling
them sideways through the door on the panel,
connections side.
With the accessory FTMxT, the filtration is
made through compact filters with a F7 filtration degree.

Accessories

PLxT supply and suction plenum:


compatible with GAxT, GMxT and TPPLxT.
FT7MxT compact lters F7 on fans supply:
compatible with GMxT, SAxT and TPPxT.
B2RxT - B3RxT - B4RxT batteria a acqua
calda a 2 - 3 - 4 ranghi per impianti a 4
tubi.
SAxT suction damper: to be installed on
the base unit or on plenums.
GMxT supply grille with adjustable ns:
to be installed on the base unit or on
plenums.

GAxT suction grille with xed ns, 45


bended: to be installed on the base unit or
on plenums.
TPVSxT protection roof for vertical
installation with up supply: to be installed
on the base unit.
TPVFxT protection roof for vertical
installation: to be installed on PLxT,
FT7MxT and vertical base unit with front
supply.
TPLxT protection roof for horizontal
version with front supply: to be installed

TN1
GA1T
GM1T

TN2
GA2T
GM2T

TN3
GA3T
GM3T

TN4
GA4T
GM4T

on the base unit.


TPPLxT plenums protection roof for
horizontal installation with front supply: to
be installed on PLxT e FT7MxT from size
3 to 8.
TPFTLxT bag lter protection roof for line
installation with front supply.
P50MBT corners support feets for
horizontal and vertical versions.
P50ACT side support feets for horizontal
version.

GAxT
GMxT

Montage
V-O
V-O

TN5
GA5T
GM5T

TN6
GA6T
GM6T

TN7
GA7T
GM7T

TN8
GA8T
GM8T

SAxT

V-O

SA1T

SA2T

SA3T

SA4T

SA5T

SA6T

SA7T

SA8T

B2RxT

V-O

B2R1T

B2R2T

B2R3T

B2R4T

B2R5T

B2R6T

B2R7T

B2R8T

B3RxT

V-O

B3R1T

B3R2T

B3R3T

B3R4T

B3R5T

B3R6T

B3R7T

B3R8T

B4RxT

V-O

B4R1T

B4R2T

B4R3T

B4R4T

B4R5T

B4R6T

B4R7T

B4R8T

PLxT

V-O

PL1T

PL2T

PL3T

PL4T

PL5T

PL6T

PL7T

PL8T

FT7MxT

V-O

FT7M1T

FT7M2T

FT7M3T

FT7M4T

FT7M5T

FT7M6T

FT7M7T

FT7M8T

TPVSxT

TPVS1T

TPVS2T

TPVS3T

TPVS4T

TPVS5T

TPVS6T

TPVS7T

TPVS8T

TPVFxT

TPVF1T

TPVF2T

TPVF3T

TPVF4T

TPVF5T

TPVF6T

TPVF7T

TPVF8T

TPLxT

TPL1T

TPL2T

TPL3T

TPL4T

TPL5T

TPL6T

TPL7T

TPL8T

TPPLxT

TPPL1T

TPPL2T

TPPL3T

TPPL4T

TPPL5T

TPPL6T

TPPL7T

TPPL8T

TPFTLxT

TPFTL1T

TPFTL2T

TPPL3T

TPPL4T

TPPL5T

TPPL6T

TPPL7T

TPPL8T

P50MBT

V-O

P50MBT

P50ACT

P50ACT

V - O = This accessory can be mounted both on the vertical version and horizontal version;
V
= This accessory can be mounted only on the vertical version;
O
= This accessory can be mounted only on the horizontal version;

141

Technical data

Max. airflow
Max. airflow
Max. airflow

m3/h
m3/h
m3/h

TN1
3000
3500
3500

TN2
4100
4700
4700

TN3
5650
6400
6400

TN4
7350
8000
8400

TN5
9300
10000
10900

TN6
11700
13400
13400

TN7
15500
17800
17800

TN8
20000
20000
23000

Base unit
Enhanced unit
Total

Pa
Pa
kW

215
390
15,6

235
407
21,3

236
458
29,1

226
454
38,1

156
340
44,8

193
438
56,7

207
396
74,7

131
381
96,4

Sensible
Total

kW

10,7

14,7

20,1

26,2

33,3

41,7

55,1

70,9

kW

20

27,4

37,7

49,2

58,3

74,5

98,9

127,8

Sensible
Total

kW
kW

13,4
18,9

18,3
25,8

25,2
35,3

32,8
46,3

41,1
56,1

51,8
70,7

68,8
93,3

88,5
120,2

Sensible
Total

kW
kW

12
23,9

16,4
32,9

22,4
45,3

29,3
59,2

37,5
71,6

46,9
90,6

62,1
120,3

79,8
155,1

1
2
3

Fans available pressure


Maximum fans

4
4

Cooling power with coils 4 rows

Cooling power with coils 6 rows

Cooling power with coils 4 rows

Cooling power with coils 6 rows

kW

15

20,5

28,3

36,9

46,4

58,3

77,4

99,6

Heating power with coils 2 rows


Heating power with coils 3 rows
Heating power with coils 4 rows
Heating power with coils 6 rows

7
7
7
7

kW
kW
kW
kW

25,2
33,5
40
48,7

34
45,6
54,5
66,6

46,8
62,7
74,9
91,5

61,5
82
97,6
119,2

84,4
110,8
131,1
157,5

103,8
137,3
162,9
196,8

138
182,5
216,1
260,4

178,5
234,4
277,3
334,1

Heating power with coils 2 rows

8
8

kW
kW

14,7
19,6

19,8
26,6

27,3
36,6

36
47,9

49
64,4

60,3
79,8

80,1
106,1

103,8
136,3

kW

23,4

31,9

43,7

57

76,3

94,8

125,8

161,4

kW

28,5

38,9

53,5

69,6

91,7

114,3

151,7

194,6

Manifolds diameter 2 rows

1"

1"

1"

1"

1"

1" 1/2

1" 1/2

1" 1/2

Manifolds diameter 3 rows

1"

1"

1"

1"

1" 1/2

1" 1/2

1" 1/2

1" 1/2

Manifolds diameter 4 rows


Manifolds diameter 6 rows

1"
1"

1"
1"

1" 1/2
1" 1/2

1" 1/2
1" 1/2

1" 1/2
1" 1/2

1" 1/2
1" 1/2

1" 1/2
2"

2"
2"

Heating power with coils 3 rows


Heating power with coils 4 rows
Heating power with coils 6 rows

Sensible

COILS

Condensate discarge diameter


FAN
MOTOR
Power supply
Power/Poles (base unit)
Power/Poles (enhanced unit)
FILTERS
Plane filters efficiency
Compact filters efficiency (accessory)
Mouth sound pressure

note (1):
note (2):
note (3):
nota (4):
note (5):
nota (6):
nota (7):
nota (8):
nota (9):
nota (10):

142

1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F

280
V/n/Hz
kW/n 0,75 / 4
kW/n 1,1 / 4
9
9
10

G4
F7
52

280

315

1,1 / 4
1,5 / 4

1,5 / 4
2,2 / 4

G4
F7
54

G4
F7
55

with cooling coil ;


with heating coil, base unit;
with heating coil, enhanced unit;
alla portata aria massima 1 with cooling coil 4 rows and lters G4 fouling medium life
Air temperature enters 27 C d.b. 19 C w.b.; water temperature (In-Out) 7 C - 12C.;
Air temperature enters 27 C d.b 19 C w.b.; water temperature (In-Out) 5 C - 10C.;
Air temperature enters 10 C; water temperature (In-Out) 70 C - 60C.;
Air temperature enters 10 C; water temperature (In-Out) 45 C - 40C.;
comply with the regulation EN 779;
d = 10 m, Q =2, base version, at min. pressure, nominal air ow with cooling coil.

315

400

s,
2,2 / 4 2,2 / 4
3/4
3/4
G4
F7
57

G4
F7
56

400

500

500

4/4
5,5 / 4

4/4
5,5 / 4

5,5 / 4
7,5 / 4

G4
F7
58

G4
F7
59

G4
F7
64

Dimensions (mm)

B
C

TN models
Height
Width

A
B

mm
mm

TN1
1334
928

TN2
1334
1172

TN3
1497
1334

TN4
1497
1659

TN5
1822
1659

TN6
1822
1984

TN7
2309
1984

TN8
2309
2472

Lenght

684

684

765

765

828

828

1172

1172

kg

190

220

275

320

415

475

630

807

Weight (enhanced version coil 6R)

kg

200

223

283

321

417

502

657

813

Cod.: STNUY.02 / 1502

mm

Weight (base version coil 6R)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

143

NCS

Air handling units with 25 mm thick panels.


Air flow rate from 1,000 to 45,000 m3/h

Characteristics
The NCS series of air handling units is a direct
descendant of the NCD series. They both offer
high quality components, versatile configurations, and a complete array of available sections
and accessories.
The NCS series of air handling units is notable
due to its use of 25 mm thick sandwich panels,
which are attached to the
frame using frame panels which do not require
screws. This system allows for uniform pressure
on the case, minimizing leakage.
Thanks to a modular construction and the wide
range of accessories, the designer is always able
to select the most appropriate unit for their precise installation type.
Main Characteristics
Structure:
Aluminium sections with rounded edges and
reinforced nylon corners.

Accessories
A vast array of accessories, which can be chosen using our selection programme. The programme also makes it possible to quickly design
a unit in real-time.

144

The case is made of sealing sandwich panels,


25 mm thick, attached to the frame using an
exclusive frame panel which does not require
any screws.

Humidification systems
Chosen based on the specific intended use for
the unit, in conformance with the system chosen.

Aluminium dampers
with aerofoil blades. Precise construction guarantees low leakage.

Forward or backward curved fan blades.


The choice is made based on the requested
aeraulic performance, and with attention to output and noise level.

Filter systems
All types of filter systems generally used in air
handling units are available, all of which guarantee conformance with the current regulations
regarding environmental air quality.

Silencers
Available in various lengths. Constructed of
rock wool, surfaces in contact with the air are
protected using polyester film and held inside a
micro-perforated galvanized steel sheet.

Heat exchange coils


can be removed on slides and are provided in Various types of heat recovery systems
various materials based on usage and heating Make it possible to respect current energy saving regulations.
system.

Technical information
NCS

air ow rate (m3/h)


2
907
1566
1912
2506
3059
3445
4206
4966
6415
7582
9238
11370
13582
17055
20609
24618
29711

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

2,5
1134
1958
2390
3132
3823
4307
5257
6207
8019
9477
11548
14213
16978
21319
25761
30772
37139

3
1361
2349
2867
3758
4588
5168
6308
7449
9623
11372
13857
17055
20373
25583
30913
36926
44566

3,5
1588
2741
3345
4385
5352
6029
7360
8690
11227
13268
16167
19898
23769
29847
36065
43081
51994

Vel.: Face velocity on the battery pack heat exchange

Dimensional data (mm)


NCS

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Width
684
1009
1171.5
1009
1171.5
1009
1171.5
1334
1659
1659
1984
1984
2309
1984
1984
2309
2309

External dimensions
Height*
521.5
521.5
521.5
684
684
846.5
846.5
846.5
846.5
1009
1009
1171.5
1171.5
1659
1984
1984
2309

Width
613
938
1100.5
938
1100.5
938
1100.5
1263
1588
1588
1913
1913
2238
1913
1913
2238
2238

Internal dimensions
Height
409.5
409.5
409.5
572
572
734.5
734.5
734.5
734.5
897
897
1059.5
1059.5
1547
1872
1872
2197

Cod.: SNCSUY.00 / 0912

*declared external height does not include the base (120 mm)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

145

NCD

Air handling units

Aermec
is a company of the Giordano Riello
International Group, which
participates in the program Eurovent.
Products are listed on the site
www.eurovent-certification.com

Features
24 sizes of central air handling units with
double panelling with panel thickness of 50
mm
Support structure realised in aluminium alloy
sections and a large choice of panels.
Wide range of sections and components to
satisfy all plant engineering requirements
Double intake centrifugal fans with forward
or reverse blades.
PLUG FAN type fan with Inverter regulation,
able to adapt to the most varied system requirements.
Main Features
Structure:
In aluminium sections with rounded edges
both internally and externally allowing greater cleanliness
New panelling and gaskets, able to guarantee
reduced seepage in compliance with the

EN1886 Standard
Large availability of filters:
Reduction of noise emission thanks to the use
Filters with large surfaces to reduce the
of material with high sound-absorption
pressure drops and increase the duration
power.
- Cell pre-filters
Small dimensions and contained height.
- Roll filters
- Bag filters
Internal components:
- Absolute filters
New high-efficiency heat exchangers with - Activated carbon filters
small pressure drops
- Germicidal lamp
Mixing chamber with three dampers
The configurations for the mixing chambers New efficient drop eliminator in PVC
with three dampers are the following:
New heat recoverers with high heat exchange
- two upper dampers and an internal one for
recirculation;
- two front dampers and a horizontal one
Electric components
for recirculation (for overlapping control Electronic regulation available able to optimiunits);
se the performance and simplify installation
- two lateral internal dampers and an internal
of the control unit itself
for recirculation (configuration for expulsion New high performance selection software.
and non-ducted fresh air intake)

Accessories
Wide range of accessories among which:
- Technical rooms
Accessories for air intake/exhaust sections:
- flange;
- blank panel (to be perforated with care by the
customer);
- anti-vibration sheet on the intake/flow vents
(with or without damper) with earth cable;
- aluminium grille (for internal dampers only);
- manual command on the dampers;
- proportional servo-control;

146

- proportional servo-control with spring return;


- pedestrian grill on the floor dampers.
Accessories for the fan-motor sections:
- Damper on the flow vent;
- overpressure damper;
- micro switch on the inspection hatch;
Accessories common to several sections:
- Spot light with window with 24V bulb (the
installer must envision the 24V power supply);

- manometer with dial;


- pressure switch;
- instruments-probes holder GJ 1/4" double
sleeve;
- floor reinforced with non-slip sheet steel.

Technical data
NCD 1
NCD 2
NCD 3
NCD 4
NCD 5
NCD 6
NCD 7
NCD 8
NCD 9
NCD 10
NCD 11
NCD 12
NCD 13
NCD 14
NCD 15
NCD 16
NCD 17
NCD 18
NCD 19
NCD 20
NCD 21
NCD 22
NCD 23
NCD 24

Air ow rate m/h


1.134
1.958
2.390
3.132
3.823
4.307
5.257
6.207
8.019
9.477
11.548
14.213
16.978
19.742
25.761
30.772
37.139
47.187
49.235
55.283
61.331
67.379
73.427
79.475

Coil section m2
0,13
0,22
0,27
0,35
0,42
0,48
0,58
0,69
0,89
1,05
1,28
1,58
1,89
2,19
2,86
3,42
4,13
4,8
5,47
6,14
6,81
7,49
8,16
8,83

The performance refers to an air speed through the coils equal to 2.5 m/s.

147

Technical Data
SEZ A

734

894

1054

1214

SEZ B
1374

1534

1694

1854

2014

height
with Stand

height without
Stand

620

780

940

1100

1260

1420

1580

1740

1900

645

525

NCD1
1370-1640
m3/h

NCD1A
1880-2260
m3/h

NCD2
2350-2820
m3/h

NCD3
2870-3450
m3/h

NCD3C
3390-4070
m3/h

NCD4B
3890-4670
m3/h

NCD5B
4380-5250
m3/h

NCD6B
4860-5840
m3/h

NCD6D
5330-6400
m3/h

805

685

NCD1B
1970-2360
m3/h

NCD3A
2720-3260
m3/h

NCD4
3400-4080
m3/h

NCD5
4150-4980
m3/h

NCD6A
4900-5870
m3/h

NCD7A
5620-6740
m3/h

NCD8A
6320-7590
m3/h

NCD8C
7020-8430
m3/h

NCD8F
7700-9240
m3/h

965

845

NCD2A
2580-3090
m3/h

NCD4A
3550-4260
m3/h

NCD6
4440-5330
m3/h

NCD7
5420-6500
m3/h

NCD8
6400-7680
m3/h

NCD8D
7350-8820
m3/h

NCD9
8270-9920
m3/h

NCD9C
NCD9F
9180-11020 10070-12090
3
m /h
m3/h

1125

1005

NCD3B
3180-3820
m3/h

NCD5A
4390-5270
m3/h

NCD6E
5490-6580
m3/h

NCD8B
6700-8030
m3/h

NCD8H
7910-9490
m3/h

NCD9A
NCD10
NCD10C
NCD11
9080-10890 10210-12250 11340-13610 12440-14930
m3/h
m3/h
m3/h
m3/h

1285

1165

NCD6C
5220-6270
m3/h

NCD7B
6530-7830
m3/h

NCD8G
7970-9560
m3/h

NCD9E
NCD10A
NCD10F
NCD11A
NCD12
9410-11290 10800-12960 12150-14580 13500-16200 14810-17770
m3/h
m3/h
m3/h
m3/h
m3/h

1445

1325

NCD8E
7570-9090
m3/h

NCD9B
NCD10B
NCD10G
NCD11D
NCD12A
NCD12C
9240-11090 10910-13100 12530-15040 14100-16920 15660-18800 17180-20610
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

1765

1645

NCD11B
NCD12B
NCD13A
NCD13D
NCD14B
NCD10D
11790-14150 13920-16710 15990-19190 17990-21580 19980-23980 21920-26300
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

2085

1965

NCD14A
NCD14E
NCD15
NCD13B
19440-23330 21870-26250 24300-29160 26650-31980
3
3
3
m /h
m /h
m3/h
m /h

2405

2285

NCD15D
NCD15G
28620-34350 31390-37670
m3/h
m3/h

2565

2445

NCD16B
33760-40510
m3/h

SEZ B

SEZ A
height
with Stand

2334

2654

2974

3294

3614

3934

4254

4574

2220

2540

2860

3180

3500

3820

4140

4460

645

height without
Stand
525

805

685

NCD9D
9200-11040
m3/h

965

845

NCD11C
NCD10E
12030-14440 13990-16790
3
m3/h
m /h

1125

1005

NCD11E
NCD12D
NCD13C
14860-17830 17280-20730 19700-23640
m3/h
m3/h
m3/h

1285

1165

NCD13
NCD14
NCD14C
NCD15B
17690-21230 20570-24680 23450-28140 26330-31590
m3/h
m3/h
m3/h
m3/h

1445

1325

NCD14D
NCD15C
NCD15E
NCD16A
NCD13E
20520-24620 23860-28630 27200-32640 30540-36650 33880-40660
m3/h
m3/h
m3/h
m3/h
m3/h

1765

1645

NCD15F
NCD16C
NCD17A
NCD17D
NCD18B
NCD15A
26180-31410 30440-36530 34700-41640 38970-46760 43230-51870 47490-56990
3
3
3
3
3
m /h
m /h
m /h
m /h
m3/h
m /h

2085

1965

NCD16D
NCD17C
NCD18C
NCD19A
NCD20A
NCD21A
NCD21C
NCD16
31840-38200 37020-44430 42210-50650 47390-56870 52570-63090 57760-69310 62940-75530 68130-81750
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

2405

2285

NCD17
NCD18
NCD19
NCD20
NCD21
NCD22
NCD23
NCD24
37500-45000 43600-52320 49710-59650 55810-66980 61920-74300 68030-81630 74130-88960 80240-96280
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

2565

2445

NCD17B
NCD18A
NCD19B
NCD20B
NCD21B
NCD22A
NCD23A
NCD24A
40330-48390 46890-56270 53460-64150 60030-72030 66590-79910 73160-87790 79730-95670 86290-103550
3
3
3
3
3
3
3
m /h
m3/h
m /h
m /h
m /h
m /h
m /h
m /h

The performance refers to an air speed through the coils equal to 2.5 m/s.

148

Dimensional (mm)

Section A
645
645
645
805
805
965
965
965
965
1.130
1.130
1.285
1.285
1.285
2.085
2.085
2.405
2.405
2.405
2.405
2.405
2.405
2.405
2405

Section B
735
1055
1215
1055
1215
1055
1215
1375
1695
1695
2015
2015
2335
2655
2015
2335
2335
2655
2975
3295
3615
3935
4255
4575

Cod.: SNCDUY.02 / 1502

NCD 1
NCD 2
NCD 3
NCD 4
NCD 5
NCD 6
NCD 7
NCD 8
NCD 9
NCD 10
NCD 11
NCD 12
NCD 13
NCD 14
NCD 15
NCD 16
NCD 17
NCD 18
NCD 19
NCD 20
NCD 21
NCD 22
NCD 23
NCD 24

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

149

NCD H

Air handling units


With modular sections

Features
Fan sections, exchange coils, filters and external air intakes:
- plug fans for all sizes, in stainless steel or treated material, equipped with guides and supports reduced to a minimum;
- coils and heat recovery units in Cu/Cu, waterproof Cu/Cu, stainless steel/Cu or stainless steel/
stainless steel;
- class F7 filters positioned upstream and on the
pick-up points of the unit, class F8/F9 downstream (possibility to equip the unit with filters with
a germicidal capacity);
- external air intakes scaled for speeds of less
than 2m/s, and equipped with suitable protective means.
Humidification, silencers, drop eliminators:
- steam humidification, either direct or with a
producer operating with immersed electrodes;

150

- suitable distances are maintained between the


humidification and the subsequent component;
- drop eliminators subjected to antibacterial treatment or made of stainless steel.
Performance and safety characteristics:
- the unit performance levels are certified according to the Eurovent programme;
- the unit is supplied complete with all the electrical and electronic components for correct
operation, and therefore carries the EC mark
showing that it satisfies the safety requisites of
the relevant directives.
Inspection and cleaning:
- access openings, drainage panels and adequate
lighting in every section;
- curved inner corners to avoid the accumulation
of dirt;
- edges and slits have been avoided and all per-

manent joints are sealed;


- the drainage outlets are fitted with easy-toinspect drain-taps.
Panelling and inner surface:
- the precise frame-panelling coupling allows
you to reach casing air seepage values that fall
within class B of Standard UNI EN 1886, with
the certification of the TV laboratories;
- the materials used offer a good resistance to
cracking, splintering, flaking and abrasion, they
can be washed and disinfected, and they do not
favour the proliferation of biological agents or
agents that encourage bioburden reduction
(antibacterial treatment with certified bioburden
reduction).

Technical data

NCD H 2
NCD H 3
NCD H 4
NCD H 5
NCD H 6
NCD H 7
NCD H 8
NCD H 9
NCD H 10
NCD H 11
NCD H 12
NCD H 13
NCD H 14
NCD H 15
NCD H 16

Air ow rate m3/h


1800
2520
3130
3820
4500
5080
6230
7340
9470
10730
13860
17500
21300
25780
30780

Coil section m2
0,202
0,278
0,348
0,425
0,502
0,566
0,69
0,815
1,053
1,191
1,539
1,944
2,369
2,862
3,419

The performance levels refer to an air speed through the coils equal to 2.5 m/s.

Dimensions (mm)

Section A
805
805
805
805
805
1125
1125
1125
1125
1445
1445
1765
1765
2085
2085

Section B
735
895
1055
1215
1375
1055
1215
1375
1695
1375
1695
1695
2015
2015
2335
Cod.: SNCDHUY.02 / 1401

NCD H 2
NCD H 3
NCD H 4
NCD H 5
NCD H 6
NCD H 7
NCD H 8
NCD H 9
NCD H 10
NCD H 11
NCD H 12
NCD H 13
NCD H 14
NCD H 15
NCD H 16

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

151

SPL
025/130

Swimming Pool Lines


Air handling unit
high efficiency for health centres.
Air flow from 4,000 to 13,000 m3/h.

R410A

ing
m
m
s
Swi l Line
Poo

TECHNOLOGY

HIGH
EFFICIENCY

The units from the SPL series represent the ideal solution to guarantee the comfort conditions in small-medium spaces such as health centres, spa areas,
tness centres, small swimming pools, sports facilities, etc.
The unit contains a refrigerant circuit and a system for the recovery of sensible and latent heat coming from the humid air extracted from the space,
thereby being optimised for the reduction of energy consumption. The main function of the unit, which is a "plug and play" machine ready for use, is
that of dehumidifying and at the same time ensuring control of the temperature and humidity conditions of the area served.
The unit is tted with an efcient heat recovery system on the water side, to be used to partially heat the swimming pool water at no cost.
The structure and all the internal components are built to ensure the maximum resistance to corrosion.

Characteristics
VERSIONS
7 sizes available.

REFRIGERANT CIRCUIT:
valve (standard); this allows the accurate con Fitted with scroll compressor supplied with
trol of the supply air temperature. The frame
rubber anti-vibration feet, refrigerant gas/air
of the coil is in painted galvanised steel to
heat exchanger coil with copper tubes and preensure the maximum resistance to corrosion.
painted aluminium fins and painted frame, filter, electronic expansion valve, liquid receiver, ELECTRICAL PANEL:
filter drier, controls (pressure transducers and
Power and controls panel unit mounted.
visual indicators) and safeties (high and low
Electrical installation for the connection of
pressure pressostats), brazed copper connecpower and controls, set in tubes or conduits
tions, refrigerant charge of environmentally
with glands and grommets, IP55 protective
friendly R410A. The refrigerant circuit is
rating. Remote panel supplied as standard for
installed in a compartment isolated from the
the control of all the main functions and disair flow to facilitate checks and maintenance.
play of alarms.

STRUCTURE:
Anodised aluminium profile with reinforced
nylon corner pieces. Casing made from sandwich type panels (50mm thickness), with
internal surface pre-painted galvanised steel,
external in pre-painted galvanised steel and
insulating material hot injected polyurethane
with a density of 42 kg/m, fixed without
screws but with panel locking profiles, doors
with keyless handles. This fixing method
allows a uniform pressure on the casing,
ensuring an excellent resistance to the leakFAN SECTIONS:
age of air and water. The support structures
Treated with epoxy paint resistant to corroand the seals around components are comsion, fitted with "plug fans" with backward
pletely painted to ensure the maximum corrocurved impeller of high output. Electrical
sion resistance. The bottom surfaces of the
motor directly coupled to the impeller suitaunit are fitted with drain panels in pre-painted
ble for inverter control (standard).
galvanised steel with a central drain point
piped sideways.
FILTRATION SYSTEMS:
Fitted as standard with panel filters in extract
THERMAL RECOVERY SECTION:
(G4 efficiency class according to EN779) and
High efficiency static cross flow in pre-paintpanel + bag filters (G4 + F9 efficiency class
ed aluminium. Including dampers: recirculataccording to EN779) meet the requirements
ing damper used for the quick start up of the
for the applicable standards for indoor air
space, recirculating damper for the "primary"
quality. Dirty filter differential pressure
cycle, dampers on the air inlet and extract.
switches are provided as standard.
All dampers are manufactured in anodised
aluminium and are individually controlled by HOT WATER HEATING COIL:
an external actuator for precise air flow con With copper tubes and pre-painted aluminitrol.
um fins to heat the supply air after dehumidification, controlled by a modulating 3 way

152

Operating schematics

The principal operation modes of the unit are shown in the example schematics below.
In all the following schematics the hot water coil is always operating because the external air temperature is
below 10C with a required supply air temperature to compensate for the heat losses from the building.

External air

Extract

"Start up" cycle

Supply

The operating mode is with no external air ow. The whole air
ow is recirculated through damper 5 and returned to the pool
area.
The hot water coil is operational.
The "start up cycle" is activated for the time necessary to heat up
the area.

"Dehumidication" cycle

6
2

External air

Extract

Dehumidication with external air

Supply

4 3
1

The operating mode is with external air dehumidifying the space,


compensating for evaporation from the pool. The refrigerant
circuit (consisting of the compressor 1 and the coils 2 and 3)
allows the sensible and latent heat recovery of the extracted
air to be transferred to the supply air or the water, through the
thermal heat exchange consisting of the double heat exchanger
on the water side.
The hot water coil 4 supplements, if necessary, the heating
capacity provided by the refrigerant circuit, placed downstream
of the entering air ow (condensing coil 3).

6
5

External air

Extract

Dehumidication with external air and primary cycle

Supply

4 3

When required the compressor also assists in the


dehumidication of the pool area.
The supply air ow is modulated by the fan inverter to reach the
required hygrometric conditions.
As a function of the external ambient temperature the unit
modies the operating mode to achieve the best efciency
possible.

Supply

External air

Extract

Dehumidication with external air (night cycle)


In night time mode the unit modies the operating settings to
adapt to the changes of evaporation from the pool and reduce
consumption to the minimum.

4 3
1

153

Technical data

SPL

025

040

060

100

130

m3/h

2.500

4.000

6.300

10.000

13.000

Available pressure (supply/extract)

Pa

400

400

400

400

400

Heat recovery capacity recovered1

kW

7,9

12,6

20,4

32,0

41,5

80,8

79,3

80,1

79,5

79,4

Refrigerant circuit recovered capacity1

kW

7,5

10,5

21,3

31,7

45,7

Total recovered capacity1

kW

15,4

23,1

41,6

63,7

87,3

Compressor power input1

Nominal airow (supply/extract)

Max heat recovery efciency1

kW

1,3

1,6

3,7

6,0

8,4

COP1

11,8

14,4

11,2

10,6

10,4

COP2

3,9

4,0

4,1

4,0

4,1

Total dehumidication capacity1

kg/h

15,5

25,2

40,1

63,7

82,7

Supply fan power input

kW

1,6

2,6

3,7

5,9

7,6

Extract fan power input

kW

1,2

1,9

2,7

4,5

5,7

Type / number of compressors

Scroll / 1

Hot water heating coil (standard)


Capacity (without recovery active)1

kW

26,1

35,4

61,6

95,3

124,5

Water ow rate 3

l/h

2.250

3.050

5.300

8.200

10.700

Water pressure drop 3

kPa

23,5

43,7

33,1

48,8

46,3

Plate heat exchanger R410A/non aggressive water (standard)


Water ow rate nominal4

l/h

950

1.120

2.500

3.600

5.400

Pressure drop4

kPa

19

19

31

32

33

Plate heat exchanger accessible non aggressive water/pool water (standard)


Water ow rate nominal pool5

l/h

1.200

1.400

3.100

4.500

6.800

Pressure drop pool side5

kPa

32,4

34

31,4

33

34,5

Pressure drop intermediate circuit side5

kPa

21,2

22,3

20,6

21,6

22,5

Electrical data
Unit power supply

400 V - 3 ph - 50 Hz

Maximum total current input


supply fan

3,5

6,2

11

14,6

15

Maximum total current input


extract fan

2,6

4,9

6,4

11,3

11,3

Unit maximum current input

11,6

17,1

32,4

49,3

61,3

Unit starting current

32,1

46,1

91,4

181,9

184,3

1
2
3

External air 0C,80% RH; internal air 29C,60% RH.


Values as per conditions of D.M. 7 april 2008 for heating only operation.
Water temperature inlet/outlet 70/60C; water pressure drop including
3 way valve.
Water temperature inlet/outlet non aggressive 27/37C.
Water temperature inlet/outlet intermediate circuit 37/27C;
water temperature inlet/outlet pool 25/35C
Preliminary technical data, subject to modification.

4
5

154

Dimensional data (mm)

B
SPL

025

040

060

100

130

Height (including base H=120mm)

mm

1.765

1.765

2.245

2.405

2.405

Width

mm

895

895

1.055

1.375

1.695

Length

mm

3.230

3.390

4.190

4.190

4.670

kg

900

1.000

1.350

2.060

2.600

Cod.: SSPL025_130UY.01 / 1406

Weight

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data .

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

155

SPL
160/250

Swimming Pool Lines


Air handling unit
high efficiency for health centres.
Air flow from 16,000 to 25,000 m3/h.

R410A

ing
m
m
s
Swi l Line
Poo

TECHNOLOGY

HIGH
EFFICIENCY

The units from the SPL series represent the ideal solution to guarantee the comfort conditions in medium-large spaces such as health centres, spa areas,
tness centres, swimming pools, sports facilities, etc.
The unit contains a refrigerant circuit and a system for the recovery of sensible and latent heat coming from the humid air extracted from the space,
thereby being optimised for the reduction of energy consumption. The main function of the unit, which is a "plug and play" machine ready for use, is
that of dehumidifying and at the same time ensuring control of the temperature and humidity conditions of the area served.
The unit is tted with an efcient heat recovery system on the water side, to be used to partially heat the swimming pool water at no cost.
The structure and all the internal components are built to ensure the maximum resistance to corrosion.

Characteristics
VERSIONS
3 sizes available.

supply air after dehumidification, controlled


REFRIGERANT CIRCUIT:
by a modulating 3 way valve (standard); this
Fitted with scroll compressor supplied with
allows the accurate control of the supply air
rubber anti-vibration feet, refrigerant gas/air
STRUCTURE:
temperature. The frame of the coil is in paintheat exchanger coil with copper tubes and pre Anodised aluminium profile with reinforced
ed galvanised steel to ensure the maximum
painted aluminium fins and painted frame, filnylon corner pieces. Casing made from sandresistance to corrosion.
ter, electronic expansion valve, liquid receiver,
wich type panels (50mm thickness), with
filter drier, controls (pressure transducers and
internal surface pre-painted galvanised steel,
ELECTRICAL PANEL:
visual indicators) and safeties (high and low
external in pre-painted galvanised steel and
Power and controls panel unit mounted.
pressure pressostats), brazed copper connecinsulating material hot injected polyurethane
Electrical installation for the connection of
tions,
refrigerant
charge
of
environmentally
with a density of 42 kg/m, fixed without
power and controls, set in tubes or conduits
friendly R410A. The refrigerant circuit is
screws but with panel locking profiles, doors
with glands and grommets, IP55 protective
installed in a compartment isolated from the
with keyless handles. This fixing method
rating. Remote panel supplied as standard for
air flow to facilitate checks and maintenance.
allows a uniform pressure on the casing,
the control of all the main functions and disensuring an excellent resistance to the leakplay of alarms.
FAN SECTIONS:
age of air and water. The support structures
Treated with epoxy paint resistant to corroand the seals around components are comsion, fitted with "plug fans" with backward
pletely painted to ensure the maximum corrocurved impeller of high output. Electrical
sion resistance. The bottom surfaces of the
motor directly coupled to the impeller suitaunit are fitted with drain panels in pre-painted
ble for inverter control (standard).
galvanised steel with a central drain point
piped sideways.
FILTRATION SYSTEMS:
Fitted as standard with panel filters in extract
THERMAL RECOVERY SECTION:
(G4 efficiency class according to EN779) and
High efficiency static cross flow double plate
panel + bag filters (G4 + F9 efficiency class
heat exchanger in pre-painted aluminium.
Including dampers: recirculating damper used
according to EN779) meet the requirements for
for the quick start up of the space, recirculatthe applicable standards for indoor air quality.
ing damper for the "primary" cycle, dampers
Dirty filter differential pressure switches are
on the air inlet and extract. All dampers are
provided as standard.
manufactured in anodised aluminium and are
individually controlled by an external actuaHOT WATER HEATING COIL:
tor for precise air flow control.
Water coil with copper tubes and pre-painted
aluminium fins and painted frame to heat the

156

Operating schematics

The principal operation modes of the unit are shown in the example schematics below.
In all the following schematics the hot water coil is always operating because the external air temperature is
below 10C with a required supply air temperature to compensate for the heat losses from the building.

"Start up" cycle

External air

Extract

Top view

Supply

The operating mode is with no external air ow. The whole air
ow is recirculated through damper 5 and returned to the pool
area.
The hot water coil is operational.
The "start up cycle" is activated for the time necessary to heat up
the area

"Dehumidication" cycle
Dehumidication with external air

External air

The operating mode is with external air dehumidifying the space,


compensating for evaporation from the pool. The refrigerant
circuit (consisting of the compressor 1 and the coils 2 and 3)
allows the sensible and latent heat recovery of the extracted
air to be transferred to the supply air or the water, through the
thermal heat exchange consisting of the double heat exchanger
on the water side.
The hot water coil 4 supplements, if necessary, the heating
capacity provided by the refrigerant circuit, placed downstream
of the entering air ow (condensing coil 3).

External air

When required the compressor also assists in the


dehumidication of the pool area.
The supply air ow is modulated by the fan inverter to reach the
required hygrometric conditions.
As a function of the external ambient temperature the unit
modies the operating mode to achieve the best efciency
possible.

External air

Top view

In night time mode the unit modies the operating settings to


adapt to the changes of evaporation from the pool and reduce
consumption to the minimum.

Extract

Supply

5
1

4 3

Dehumidication with external air and primary cycle


Top view

Supply

Extract

5
1

4 3

Dehumidication with external air (night cycle)

Extract

Top view

Supply

4 3

157

Technical data

SPL

160

200

250

Nominal airow (supply/extract)

m3/h

16.000

20.000

25.000

Available pressure (supply/extract)

Pa

400

400

400

Heat recovery capacity recovered1

kW

59,6

68,6

89,2

Max heat recovery efciency1

93

86

89

Refrigerant circuit recovered capacity1

kW

46,3

53,6

69,4

Total recovered capacity1

kW

105,9

122,2

158,6

Compressor power input1

kW

8,5

9,2

12,8

COP1

12,5

13,3

12,4

COP2

4,0

3,9

3,9

Total dehumidication capacity1

kg/h

102,2

127,6

159,5

Supply fans power input

kW

10,9

13,7

17,7

Extract fans power input

kW

8,3

9,8

12,4

Type / number of compressors

Scroll / 1

Hot water heating coil (standard)


Capacity (without recovery active)1

kW

131,9

182,7

205,9

Water ow rate 3

l/h

11.300

15.700

17.700

Water pressure drop 3

kPa

43,7

37,9

42,2

Plate heat exchanger R410A/non aggressive water (standard)


Water ow rate nominal4

l/h

5.760

6.450

8.260

Pressure drop4

kPa

33

33

33

Plate heat exchanger accessible non aggressive water/pool water (standard)


Water ow rate nominal pool5

l/h

7.200

8.100

10.400

Pressure drop pool side5

kPa

34,2

34,7

34,2

Pressure drop intermediate circuit side5

kPa

22,3

22,7

22,2

Electrical data
Unit power supply

400 V - 3 ph - 50 Hz

Maximum total current input


supply fans

29,2

41

42

Maximum total current input


extract fans

22

22,6

30

Unit maximum current input

86,2

99,6

123

Unit starting current

209

223

287

1
2

External air 0C,80% RH; internal air 29C,60% RH.


Values as per conditions of D.M. 7 april 2008 for heating only
operation.
Water temperature inlet/outlet 70/60C; water pressure drop
including 3 way valve.
Water temperature inlet/outlet non aggressive 27/37C.

3
4

158

Water temperature inlet/outlet intermediate circuit 37/27C;


water temperature inlet/outlet pool 25/35C
Preliminary technical data, subject to modication.

Dimensional data (mm)

SPL

160

200

250

Height

mm

2.085

2.405

2.405

Width

mm

2.015

2.175

2.335

Length

mm

5.790

5.790

6.430

kg

2.780

3.250

3.580

Cod.: SPL160_250UY.01 / 1406

Weight

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data .

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

159

ENERGY

Air handling unit for outside air


with high energy efficiency.
Airflow from 4,000 to 25,000 m3/h.

R410A
TECHNOLOGY

HIGH
EFFICIENCY

The units of the Energy series represent the maximum expression of technical innovation for the treatment of outside air. The Energy series has been
specically designed to reduce to the minimum the operating energy consumption, which represents around 80% of the entire life cycle cost of an air
treatment unit. The double heat recovery system (static and active) and the innovative cooling and adiabatic humidication system, allow the supply
of air at the desired conditions with the minimum energy expenditure. The damper for total bypass allows free-cooling in the intermediate season,
exploiting to the maximum the free external thermal contribution. The Energy series is manufactured in full compliance with the standard EN1886
with regards to mechanical resistance, air leakage, thermal and acoustical insulation of the casing.

Characteristics
VERSIONS
5 sizes available.

and bag), to satisfy any filtration requirement


and ensure compliance with the current air
quality standards. Dirty filter pressure switches supplied as standard.

PLUG AND PLAY:


The units of the Energy series are delivered
ready for use. In particular, the machine is
STATIC HEAT RECOVERY:
equipped with a complete control system and Integrated reversible heat pump. Tandem
the refrigerant circuit is completely assembled
scroll compressor (single for sizes 040 and
and tested, minimising the time and cost of
060) supplied with rubber anti-vibration feet;
installation and start up.
continuous capacity control through an
inverter to ensure the maximum energy savSTRUCTURAL ASSEMBLY:
ings even at part load. Double expansion
In aluminium profile with rounded edges and
valve electronically controlled. 4 way refrigreinforced nylon corner pieces. The casing is
erant cycle reversing valve. Coils manufacmanufactured from sandwich panels of 50
tured with copper tubes and prepainted alumm thickness, fixed to the frame with an
minium fins. Environmentally friendly
exclusive panel fixing without the use of
refrigerant R410A ensures improved energy
screws. This fixing method allows a uniform
efficiency for the refrigerant cycle.
pressure on the casing, ensuring an excellent
resistance to the leakage of air and water.
RE-HEAT COIL:
Water in the Standard version (optional) and
MODULATING BYPASS DAMPER:
Eco version (standard), hot gas in the Dry ver In aluminium with opposed aerofoil blades,
sion (standard).
installed in the extract air flow to permit freecooling. Additional recirculating damper (only COOLING SYSTEM:
in the Eco version). The accurate manufactur Adiabatic with water spray in the extract air,
ing minimises air leakage.
with self cleaning spray nozzles and high
pressure pump module, having the function
PLUG FANS:
of maximising the heat exchange in the dou Very high efficiency directly coupled to the
ble heat recovery system.
motor. Inverter for continuous control of supply and extract air flow.
WATER HUMIDIFICATION SYSTEM:
Spray in the supply air.
FILTRATION SYSTEMS:
Lower surfaces of the unit equipped with
Various types of filters are available (panel
drain panels with central condensate drain to

160

ensure the continuous drainage of water and


avoid stagnation.
ELECTRICAL PANEL:
Complete with power and controls unit
mounted. Remote panel for the control of all
the main functions and display of alarms.
MICROPROCESSOR CONTROLLER:
Capable of controlling the various operating
modes (control of outside air, control of total
air), ensuring the maximum energy saving in
each operating condition. RS485 interface
supplied as standard (MODBUS protocol) for
connection to a supervisory systems and
remote control. Manual season change over
(summer/winter).
ON DEMAND:
Hot water re-heat coil (only Standard version,
as standard on Eco version), enthalpy freecooling (available only with ambient temperature control), bag filters.

Refrigerant circuit with


inverter compressor

Fan inverter

VERSION

Modulating dampers
for free-cooling

Re-heater coil
(optional)

Double static heat


recovery

Electrical panel with


power and controls

Recirculating damper

Hot gas re-heat

Water re-heat

ENERGY STD

Optional

ENERGY DRY

ENERGY ECO

Adiabatic cooling / humidication

Humidication system
pump

161

Technical data

Energy

040

060

100

160

250

Air ow nominal

m3/h

4.000

6.000

10.000

16.000

25.000

Air ow minimum

m3/h

2.800

4.200

7.000

11.200

17.500

kW

2,2

5,5

7,5

15

Current input at max capacity

5,4

9,9

13,5

27,1

Available supply static pressure

Pa

300

300

300

300

300

Available extract static pressure

Pa

200

200

200

200

200

Max motor capacity oversized fans

kW

7,5

11

15

Available supply pressure

Pa

500

500

500

500

500

Available extract pressure

Pa

400

400

400

400

400

Recovered heat capacity1, 3

kW

16,2

23,4

38

63,3

100,8

75,4

72,3

71,3

74,0

75,4

Cooling capacity heat recovery circuit active


1

kW

19,1

27,8

45,6

73,8

97,6

Compressor power input 1

kW

7,3

9,4

15,3

22

25

Compressor current input 1

13,8

13,2

24,12

32,5

37

3,5

3,8

3,8

4,1

4,4

kW

12,5

21,9

35,6

59,2

94,2

76,6

74

72,1

74,8

76,2

Heating capacity heat recovery circuit active


2

kW

24,2

32,1

56,8

84,6

109,8

Compressor power input 2

kW

7,4

8,0

17,8

19,1

22,6

Compressor current input 2

15,9

11,3

29,1

29,2

34,7

3,9

4,5

3,9

4,7

4,8

Max motor capacity standard fans

Heat recovery output1, 3

E.E.R. total 1
Recovered heat capacity2, 3
Heat recovery output2, 3

C.O.P. total 2
Type compressors/ number

Scroll / 1

Scroll / 2

Power supply

400V / 3Ph+N / 50Hz

Pump capacity adiabatic cooling circuit

kW

0,46

0,46

0,46

0,69

0,69

Humidication capacity

g/kg

Water ow rate

kg/h

24

36

60

96

150

Heating capacity water coil 4

kW

25,4

33,9

60,7

102,0

133,6

m3/h

1,09

1,50

2,60

4,38

5,87

Pressure drop water side

kPa

Pressure drop air side

Pa

28

41

33

52

80

Water ow rate

1
2

162

External air 35C, 40% RH; extract air 27C, 47,5% RH,
adiabatic cooling active.
External air 7C, 87% RH; extract air 20C, 60% RH,
adiabatic humidication active.

3
4

Constant performance over time.


Water inlet 70C, water outlet 50C.
Preliminary technical data, subject to modication.

Dimensional data (mm)

040

060

100

160

250

Height

mm

1.810

1.810

2.130

2.450

2.450

Width

mm

1.055

1.375

1.695

2.015

2.335

Length

mm

4.830

4.830

5.630

6.270

6.270

kg

1.400

1.800

2.300

2.900

3.500

Cod.: SENERGYUY.00 / 1301

Weight Standard version

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data .

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

163

RTX
09/16

Roof-top
Air/Air for external installation
with plug fans and scroll compressors
Cooling capacities 51132kW
Heating capacities 50134kW

R410A

HANDLING SECTION WITH


PLUG FAN COUPLED WITH BRUSHLESS EC MOTORS

THERMODYNAMIC HEAT RECOVERY

FREE-COOLING/ENTHALPIC FREE-COOLING OPTION

FOR MEDIUM CROWDING APPLICATIONS

Features
Independent Roof -top type air cooled air conditioner, for treatment, filtration and renewal of the
air , based on the chosen configuration . RTX units
are designed fot medium crowding applications,
like shopping malls, shops, offices , production
areas being designed for operation with 30%
external and expelled air (version MB3).
The unit based on the version and selected accessories allows the management of the free-cooling
operation, and can be equipped with a recuperator to recover the energy contained in the exaust
air allowing higher perfomances and efficiencies.
Versions
RTX_F cooling only version
RTX_H heat pump version

Configurations
MB2
with mixing chamers and two dampers
MB3
with mixing chamber with three dampers
return fan and heat recovery from expelled air
MB1
recirculation only
Each of the different configuration can be further
customized with a wide choice of accessories.
1 cooling circuit
High efficiency scroll compressors (tandem
UNEVEN) and low power consumption
Internal and external direct expansion finned heat
exchangers
. Supply and return fans (if present), of plug fan
type (EC). The impellers are so oriented to ensure
that the air flow passes through the internal com-

ponents, with the minimum noise.


Group of axial fans for extremely silent operation
placed on the condensing section with standard
condensation electronic control.
G4 air filter on the flow of outside air and on
the recovery, are installed upstream of the
components, to ensure low pressure drops.
Microprocessor control can handle the different modes of operation ensuring maximum
energy savings in any conditions.
Interfaces for connections to BMS and optional remote control available.

Accessories and fittings

SSV: Supervision system.


RS: Serial card BMS RS485
LW: Interface card LonWorks
BIP: Interface card Ethernet-pCOweb (BACNET
IP)
BAC: Interface card BACnet MS/TP pCOnet
FCT: Temperature Free-cooling
FTH: Enthalpic Free-cooling
PSTEP: Adjusting constant ow, step ow in function of the modulation of the cooling circuit.
FT7: Pocket lters F7 efciency placed on the
ow of supply air
FT9: Pocket lters F9 efciency placed on the
ow of supply air.
H10: Electronic lters placed on the ow of
supply air.
PSF: Differential pressure switch signaling fouled
lters of recovery, renewal and discharge (if
present)
PSF2: Differential pressure switch signaling
fouled lters, renewal and supply.
Gx: heating module with gas burner
BW: 2-rows-heating coil with hot water
BWV2V: 2 -rows -heating coil with hot water,
with 2-way modulating valve
BWV3V: 2-rows heating coil with hot water, with

164

3-way modulating valve


BE: Electric heating coil 2 stages (not available
with hot air generator)
BEM: Modulating electric heating coil (not available with hot air generator)
BPGC: After heating coil with hot gas .
DCPR: AC fans with pressure switch device of
speed control function of the pressure of condensation and evaporation.
AXEC: Axial fans with EC motors with speed
control function according to the pressure of
condensation and evaporation
MAN: High and low pressure gauges
U: Installed steam ramp
UP: Immersed electrode producer standard supplied and installed steam ramp
CUR: Humidication control (humidity probe in
recovery, limit humidity probe in supply , contact
ON/OFF and modulating analog output)
DP: Dehumidication control (humidity probe in
recovery) and of after-heating (if present)
SCO2: Probe CO2
(not available on MB1 FITTINGS)
SVOC: Probe VOC
(not available on MB1 FITTINGS)
STA: Room temperature probe

SUA: Room humidity probe


RF: Smoke detector
RFC: Smoke detector and recirculation damper
closure management and external air intake
PR1: Remote control panel
SCM: Modulating servo-controls (standard
supplied on the MB3 equipment or if present
FCT/FCH)
SCMRM: Modulating Servo-control with spring
return
CA: Waterproof headphones on external air
intake
CF: Flue pipe (only on version with gas burner
module)
GP: Protection grille for external coils
VT: antivibration mounts
MSSM: Delivery silencers forms (only for rear air
delivery)
MSSR: Recovery silencers forms (only for rear air
delivery)
NOTE for more details on accessories and
equipment, please referr to the technical
handbook

Features and technological advantages


Basic configuration"MB2"

RTX units have been designed with the aim of


reducing energy consumption that dictated the
result of technological choices present on the unit
that we briefly present.

HIGH EFFICIENCY VENTILATION


Ventilation is one of the major factors of
power consumption; for this reason particular attention has been given to the study and
the construction of the ventilation system.
They have been used in both supply and
recovery (if present), fans or plug fans with
EC brushless motors which enables high
performances, and low power consumption,
also compared to conventional centrifugal
fans, they have no belts or pulleys allowing
easy flow regulation, compactness, versatility
and ease of maintenance.
A particular adaptive logic allows to adjust
the air flow to the actual demand of the
system with more consequent advantages in
terms of reduction of consumption.

Plug fan supply only

Axial fans

Tandem scroll compressors


SA air supply
RA extracted air
OA external air

Axial fans for the external section of the unit


are of helycal type
As an option, the motors can be electronically controlled (EC) for the reduction in consumption of the condenser section.

MAXIMUM SEASONAL EFFICIENCY


To improve the efficiency of the cooling circuit , we have used scroll tandem compressors with different power between them
(compressors UNEVEN except for sizes 09
and 14). This feature allows a reduction of
consumptions and a better adaptability to the
demands of the system., especially in the
operation at partial loads, ensuring higher
seasonal efficiency.
AIR QUALITY IN THE ROOM
Particular attention has been given to the quality of air naturally in the room, entrusted to
the standard filters with G4 efficiency on the
flow of outside air, also available on the recovery (optional) for process applications.
They are also available as (optional) compact
filters F7 and F9 or electronic H10 flow of
fresh air .
ACTIVE THERMODYNAMIC RECOVERY
In the "MB3" setting there is also a thermodynamic recovery for the recovery of
energy contained in expelled air , in such a
way that the expelled air flow invests the
external finned heat exchanger, allowing
higher performances and efficiencies.

Configuration with thermodynamic recovery "MB3"


2

Of course all these technological advantages are


controlled by a temperature control of the latest
generation, able to handle the different modes of
operation; ensuring maximum energy savings in all
operating conditions by means of special software.

1
2
3

Plugfan supply and recovery


Axial fans
Tandem scroll compressor

165

Technical data
Mod. RTX cooling only (standard version MB2)
Cooling capacity
(1)
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
(2)
Sensitive cooling capacity
Compressor input power
EER

kW
kW
kW
W/W
kW
kW
kW
W/W

09
51,6
38,6
11,2
4,6
53,2
37,3
11,3
4,7

10
62,0
44,4
14,9
4,2
63,8
42,9
15,0
4,3

11
70,4
49,7
17,4
4,0
72,5
48,1
17,5
4,1

12
84,1
60,6
18,4
4,6
86,6
58,6
18,5
4,7

13
97,3
68,3
22,2
4,4
100,1
65,9
22,4
4,5

14
107,6
78.5
24,5
4,4
110,6
75,9
24,8
4,5

15
118,6
85,2
28,9
4,1
122,0
81,5
29,2
4,2

16
129,9
91,2
34,3
3,8
133,6
88,6
34,6
3,9

Mod. RTX cooling only (MB3 dynamic version )


Cooling capacity
(1)
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
(2)
Sensitive cooling capacity
Compressor input power
EER

kW
kW
kW
W/W
kW
kW
kW
W/W

09
52,2
38,9
11
4,80
53,8
37,4
11,1
4,80

10
62,6
44,4
14,5
4,40
64,5
43
14,6
4,40

11
71,3
50,1
16,9
4,30
73,5
48,4
17
4,30

12
85
61,2
18
4,80
87,6
59,2
18,1
4,80

13
98,4
69,1
21,6
4,60
101,3
66,7
21,8
4,60

14
108,9
78,8
23,9
4,60
112
76,1
24,1
4,60

15
120,2
85,7
28,1
4,40
123,7
82,7
28,4
4,40

16
131,9
92
33,2
4,00
135,7
88,6
33,5
4,00

Cooling
(1) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 24C b.u. (EN14511); Operating with 30% external and expelled air
(2) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 26C b.u.; Operatiing with 30% external and expelled air

RTX Heat pump version (standard version MB2)


Cooling capacity
(1)
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
(2)
Sensitive cooling capacity
Compressor input power
EER
Heating power
(3)
Compressor input power
COP

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

09
51,6
38,6
11,2
4,6
53,2
37,3
11,3
4,7
50,0
8,7
5,70

10
62,0
44,4
14,9
4,2
63,8
42,9
15,0
4,3
61,4
12
5,10

11
70,4
49,7
17,4
4,0
72,5
48,1
17,5
4,1
69,9
13,6
5,10

12
84,1
60,6
18,4
4,6
86,6
58,6
18,5
4,7
81,7
15
5,40

13
97,3
68,3
22,2
4,4
100,1
65,9
22,4
4,5
94,7
17,3
5,50

14
107,6
78.5
24,5
4,4
110,6
75,9
24,8
4,5
103,2
18,5
5,60

15
118,6
85,2
28,9
4,1
122,0
81,5
29,2
4,2
114,7
21,4
5,40

16
129,9
91,2
34,3
3,8
133,6
88,6
34,6
3,9
127,5
24,9
5,10

Mod. RTX Heat pump (MB3 dynamic version )


Cooling capacity
(1)
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
(2)
Sensitive cooling capacity
Compressor input power
EER
Heating power
(3)
Compressor input power
COP

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

09
52,2
38,9
11
4,80
53,8
37,4
11,1
4,80
51,5
8,8
5,80

10
62,6
44,4
14,5
4,40
64,5
43
14,6
4,40
63,5
12,2
5,20

11
71,3
50,1
16,9
4,30
73,5
48,4
17
4,30
73,0
13,8
5,30

12
85
61,2
18
4,80
87,6
59,2
18,1
4,80
84,6
15,2
5,60

13
98,4
69,1
21,6
4,60
101,3
66,7
21,8
4,60
98,5
17,7
5,60

14
108,9
78,8
23,9
4,60
112
76,1
24,1
4,60
107,6
18,8
5,70

15
120,2
85,7
28,1
4,40
123,7
82,7
28,4
4,40
120,1
21,9
5,50

16
131,9
92
33,2
4,00
135,7
88,6
33,5
4,00
133,9
25,6
5,20

Cooling
(1) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 24C b.u. (EN14511); Operating with 30% external and expelled air
(2) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 26C b.u.; Operating with 30% external and expelled air
Heating
(3) Internal temperature 20C b.s., 15C b.u.; External temperature 7C b.s. 6C b.u. (EN14511); Operating with 30% external and expelled air

166

Technical data
09

10

11

12

13

14

15

16

type
n
n
%
type

scroll
2
1
2
R410A

scroll
2
1
3
R410A

scroll
2
1
3
R410A

scroll
2
1
3
R410A

scroll
2
1
3
R410A

scroll
2
1
2
R410A

scroll
2
1
3
R410A

scroll
2
1
3
R410A

type
n
type
n
mm
type
n
mm
m3/h
m3/h
Pa
Pa

axial AC
2
RAD EC
1
500
RAD EC
1
500
9.500
6.650
700
194

axial AC
2
RAD EC
1
560
RAD EC
1
500
11.000
7.700
544
207

axialAC
2
RAD EC
1
630
RAD EC
1
500
13.000
9.100
567
228

axial AC
2
RAD EC
1
630
RAD EC
1
450
15.500
10.850
460
205

axial AC
2
RAD EC
2
500
RAD EC
2
450
18.000
12.600
733
222

axial AC
2
RAD EC
2
560
RAD EC
2
500
20.000
14.000
604
226

axial AC
2
RAD EC
2
560
RAD EC
2
500
22.000
15.400
528
240

axial AC
2
RAD EC
2
560
RAD EC
2
500
24.000
16.800
751
255

70
78

69
77

72
80

76
84

78
86

80
88

GENERAL DATA
Compressors
Compressors
Circuits
Capacity steps
Refrigerant gas
Fans

(3)

External fans

Fans of internal flows


(4)
(4)
(4)
nom/max
Air flow of inside fan
min
Available static pressure (flow)
(5)
Available static pressure (recovery)
(5)
Sound data
Sound pressure
Sound power
Fans of internal recovery

MB3
MB3
MB3

dB(A)
dB(A)
V/ph/Hz

Power supply

75
76
83
84
400V/3/50Hz

(3) Sizes 09-14 don't have UNEVEN compressors


(4) Not present in configurations MB2 and MB1
(5) At the nominal/maximum capacity, G4 filter medium fouling
Sound pressure
Sound pressure measured in free field (1m, Q=2) away from the outer surface of the ducted unit, Available static pressure 300Pa at nominal flow
(in accordance with the UNI EN ISO 3744).
Note: For more informations please refer to the technical documentation available on the website www.aermec.com

Dimensional data(mm)

Mod. RTX
Height
Width
Depth
Empty weight

(mm)
(mm)
(mm)
(kg)
(kg)

A
B
C

Vers.
All
All
MB2
MB3

09

10

11

12

13

14

15

16

2061
1900
3400
c.s.
c.s.

2061
1900
3400
c.s.
c.s.

2061
1900
3400
c.s.
c.s.

2373
2100
3400
c.s.
c.s.

2373
2100
3400
c.s.
c.s.

2440
2200
4000
c.s.
c.s.

2440
2200
4000
c.s.
c.s.

2440
2200
4000
c.s.
c.s.

c.s. Please contact head office


Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

167

Cod.: SRTXUY.02 / 1503

NEW

RTX
17/23

Rooftop
Air/air for external installation
with plug fans and scroll compressors
Cooling capacity 152315kW
Heating capacity 153311kW

R410A

FAN TREATMENT SECTION


PLUG FANS COUPLED WITH EC BRUSHLESS MOTORS
THERMODYNAMIC HEAT RECOVERY
FREE-COOLING/ENTHALPIC FREE-COOLING OPTION
FOR MEDIUM DENSITY APPLICATIONS
Features
Independent Roof-Top air-cooled air conditioner to treat, filter and renew air based on
the selected configuration. Being fitted to
function with 30% external and expelled air
(MB3 and MB4 versions), RTX units are
designed for medium density applications
like shopping malls, shops, offices and production areas.
Based on the version and accessories selected, the units allow you to manage free-cooling mode and, in the MB3 and MB4 versions,
there is thermodynamic recovery of the energy contained in the expelled air, allowing for
higher performance and efficiency.
Versions
RTX_F cold only
RTX_H heat pump

Configurations
MB2
single ventilating section for return air
and external air
MB3
double ventilating section for return air,
external air and expelled air. Total
free-cooling function (with 100% of
external air) and standard thermodynamic recovery function.
MB4
double ventilating section for return air,
external air and expelled air. Partial
free-cooling function (up to 50% of the
external air) and standard thermodynamic recovery function.
MB1
single ventilating section for recirculation only
Each of the different configurations can be further customised thanks to a wide selection of
accessories.
2 cooling circuits
High performance, low electrical consumption UNEVEN scroll tandem compressors

168

Finned pack direct expansion internal and


external exchangers.
Plug type (EC) flow and recovery fans (if any).
The impellers are facing so as to ensure that
the air flows through all the internal components with minimum noise.
Axial fan unit for extremely silent functioning
positioned on the condensing section.
G4 air filter installed upstream of the components to ensure low pressure drops.
Microprocessor control able to manage the
different functioning modes, ensuring maximum energy savings in any conditions of use.
Interfaces to connect to remote supervision
and control systems available as options.

Accessories

SSV: Supervision system.


RS: RS485 BMS serial card
LW: LonWorks interface card
BIP: Ethernet-pCOweb interface card (BACNET
IP)
BAC: BACnet MS/TP pCOnet interface card
FCT: Partial Temperature Free-Cooling for MB2,
MB4 versions
PSTEP: Constant ow rate adjustment, ow rate
steps based on cooling circuit modulation.
FT7: F7 efciency pocket lters positioned on the
supply air ow
FT9: F9 efciency pocket lters positioned on the
supply air ow
FTE: Electronic lters positioned on the supply
air ow.
PSF4: Differential pressure switch signalling dirty
recovery and renewal lters (if any)
Gx: Heating module with gas burner
BW: Two-row hot water heating coil.
BWV2V: Two-row hot water heating coil, with
2-way modulating valve

RFC: smoke detector and damper management


PR1: Remote control panel
SCM: modulating servo-controls (standard
on MB3 model or if temperature or enthalpic
free-cooling is present)
SCMRM: Modulating servo-controls with spring
return
VRC: Condensate drip tray with electric heater
(only available on heat pump versions)
CA: Waterproof covers on external air intake
CF: Flue pipe (only on versions with gas burner
modules)
GP: External coil protection grid
VT: anti-vibration mounts

BWV3V: Two-row hot water heating coil, with


3-way modulating valve
BE: Two-stage electric heating coil (not available
with hot air generator)
BEM: Modulating electric heating coil (not available with hot air generator)
DCPR: AC fans with pressure switch device to
regulate revolutions based on the condensation
and evaporation pressure.
AXEC: Axial fans featuring EC motors with the
function of regulating revolutions based on the
condensation and evaporation pressure
MAN: High and low pressure gauges
CUR: Humidication control (recovery humidity
probe, ow humidity limit probe, ON/OFF contact and modulating analogue output)
DP: Dehumidication (recovery humidity probe)
and post-heating (if any) control

NOTE: for more details on accessories and


equipment, please refer to the technical manual

SCO2: CO2 probe (not available on MB1 model)


SVOC: VOC Probe (not available on MB1 model)
STA: Room temperature probe
SUA: Relative humidity probe
RF: Smoke detector

Technological functions and advantages


RTX units are designed with the aim of reducing
the energy consumption that subsequently dictated the technological choices made on the
unit we will now introduce in brief.

EXTREMELY HIGH-EFFICIENCY VENTILATION As ventilation is one of the major


power consumption factors, we dedicated

particular attention to designing and constructing the ventilation system.


Both in flow and in recovery (if any), EC
brushless motor plug fans were used,
which enable high performance and
reduced consumption. Furthermore, compared to conventional centrifugal fans,
they have no belts or pulleys, thus facilitating flow adjustment and resulting in compactness, versatility and easy maintenance.
Special adaptive logic allows you to adjust
the air flow rate to actual system demand
with further resulting advantages in terms
of consumption reduction.
Axial fans for the external section of the

unit are helical. Electronic condensation


control is available as an accessory, which
regulates fan speed based on the load
required, allowing for noise reduction.
As an option, the motors can have electronic control (EC) to reduce consumption
even in the condensing part.
MAXIMUM SEASONAL EFFICIENCY To
improve cooling circuit efficiency, we used
scroll tandem compressors with different
power between them (UNEVEN compressors on all sizes). This detail allows for
consumption reduction and improved
adaptability to system demands, especially
in operation at partial loads, ensuring higher seasonal efficiency.

ters are also optionally available on the


fresh air flow.

ACTIVE THERMODYNAMIC RECOVERY


In the MB3 and MB4 configurations, the
units have a thermodynamic recovery
function to recover the energy contained
in the exhaust air, causing the expelled air
flow to hit the external finned pack
exchanger, allowing for higher performance and efficiency.

Obviously, all of these technological advantages


are controlled by cutting edge thermoregulation
that is able to manage the different functioning
modes, ensuring maximum energy savings in all
conditions of use via dedicated software.

AIR QUALITY IN THE ROOM Naturally,


we also paid special attention to the quality of the air in the room, a task entrusted to
the standard G4 efficiency filters.
Compact F7 and F9 or electronic H10 fil-

MB3 configuration with double ventilating section for return air, external air and expelled air. Total free-cooling function (with
100% of external air) and standard thermodynamic recovery function.

expelled
aria
air
espulsa

external
aria
air
esterna

ambient
Mandata
RZ
ambiente

extracted
Aria
air
estraa
169

Technical data
Mod. RTX (vers. MB1)
Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP

(1)

(2)

(3)

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

17
152
112
33,0
4,60
152
112
33,0
4,60
153
30,4
5,02

18
170
124
37,4
4,54
170
124
37,4
4,54
171
34,0
5,02

19
192
137
42,6
4,50
192
137
42,6
4,50
193
37,5
5,14

20
213
150
50,7
4,21
213
150
50,7
4,21
216
43,8
4,94

21
232
168
56,3
4,12
232
168
56,3
4,12
231
46,0
5,02

22
246
179
61,5
4,00
246
179
61,5
4,00
246
49,2
5,00

23
289
201
67,9
4,26
289
201
67,9
4,26
296
61,6
4,81

20
223
157
51,5
4,34
230
152
52,0
4,43
219
40,5
5,43

21
242
176
57,4
4,22
250
171
57,8
4,32
234
42,6
5,49

22
257
187
62,6
4,11
265
180
63,0
4,20
248
45,3
5,47

23
303
211
68,8
4,40
312
203
69,4
4,50
301
57,1
5,27

22
261
188
60,8
4,29
268
182
61,4
4,37
260
46,4
5,61

23
305
211
67,5
4,53
315
204
68,1
4,62
311
58,1
5,35

Cooling (performance is the same also for the cold only versions)
(1) Internal temperature 27C d.b., 19C w.b.; External temperature 35C d.b., 24C w.b. (EN14511); U.R. 40%;
(2) Internal temperature 27C d.b., 19C w.b.; External temperature 35C d.b., 26C w.b.; U.R. 50%
Heating
(3) Internal temperature 20C d.b., 15C w.b.; External temperature 7C d.b. 6C w.b. (EN14511)

Mod. RTX (standard MB2 vers.)


Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP

(1)

(2)

(3)

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

17
159
119
33,3
4,78
164
114
33,5
4,90
155
28,1
5,52

18
178
130
37,8
4,72
184
125
38,0
4,84
174
31,5
5,52

19
201
144
43,2
4,65
207
138
43,5
4,74
195
34,6
5,65

Cooling (performance is the same also for the cold only versions)
(1) Internal temperature 27C d.b., 19C w.b.; External temperature 35C d.b., 24C w.b. (EN14511); Functioning with 30% external air
(2) Internal temperature 27C d.b, 19C w.b.; External temperature 35C d.b., 26C w.b.; Functioning with 30% external air
Heating
(3) Internal temperature 20C d.b., 15C w.b.; External temperature 7C d.b. 6C w.b. (EN14511); Functioning with 30% external air

Mod. RTX (vers. MB3 and MB4 dynamic)


Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Cooling capacity
Sensitive cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP

(1)

(2)

(3)

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

17
160
118
32,7
4,90
165
115
32,9
5,02
159
28,3
5,63

18
180
130
37,1
4,85
185
126
37,4
4,96
179
31,9
5,62

19
202
144
42,3
4,78
208
139
42,7
4,88
202
35,2
5,75

20
226
157
50,3
4,48
232
153
50,8
4,57
228
41,2
5,52

21
245
178
55,8
4,39
252
171
56,4
4,47
244
43,5
5,60

Cooling (performance is the same also for the cold only versions)
(1) Internal temperature 27C d.b., 19C w.b.; External temperature 35C d.b., 24C w.b. (EN14511); Functioning with 30% external and expelled air
(2) Internal temperature 27C d.b., 19C w.b.; External temperature 35C d.b., 26C w.b.; Functioning with 30% external and expelled air
Heating
(3) Internal temperature 20C d.b., 15C w.b.; External temperature 7C d.b. 6C w.b. (EN14511); Functioning with 30% external and expelled air

170

Technical data
17

18

19

20S

20

21

23

4
2
6

4
2
6

4
2
6

scroll
4
2
6
R410A

4
2
6

4
2
6

4
2
6

2
630

2
630

3
560

3
560

3
630

4
560

3
500

3
500

3
500

3
560

3
560

4
560

2
450
18200
26000
36000
623
895

2
450
20300
29000
36000
470
776

2
450
23100
33000
44000
497
566

2
560
28000
40000
53000
644
788

2
560
30800
44000
53000
415
589

2
560
33600
48000
53000
731
560

83
75

83
75

85
77

85
77

87
79

90
82

GENERAL DATA
Compressors
type
no.
no.
%
type

Compressors
Circuits
Partialisation steps
Refrigerant gas
Centrifugal
External fans

type
no.
type
no.
mm
type
no.
mm
type
no.
mm
m3/h
m3/h
m3/h
Pa
Pa

Internal flow fans


(3)
(3)
(3)
(3)
(3)
(3)
min
nom
max
(4)
(4)

Internal recovery fans (MB3)

Expulsion fans (MB4)

Air flow rate


Avail. flow static pressure
Avail. MB3 recovery static pressure
Sound data
Sound power level
Sound pressure level
Electric power supply

MB3
MB3
MB3
MB4
MB4
MB4

dB(A)
dB(A)
V/ph/Hz

AC axial
4
RAD EC
3
560
RAD EC
3
500
RAD EC
2
500
25900
37000
44000
680
789
88
80
400V/3/50Hz

(3) Not present in MB2 and MB3


(4) At nominal/maximum flow rate, new clean G4 filter
Sound Pressure
Sound pressure measured in free field, at (1m, Q = 2) away from the external surface of the channelized, Steamer static 50Pa in supply and extract (according to the UNI EN ISO 9614-2).
Note: For further information, refer to the technical documentation available at www.aermec.com

Dimensional data

Mod. RTX
Height
Width
Length

(mm)
(mm)
(mm)

A
B
C

Vers.

17

18

19

20

21

22

23

All
All

2430
2200
5210

2430
2200
5210

2430
2200
5210

2430
2200
5210

2430
2200
7750

2430
2200
7750

2430
2200
7750

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 0442633111 - Fax +39 044293577
www.aermec.com

Code: SRTX17-23UY.00 / 1501

171

RTY
01/10

Roof-top
Air/Air for external installation
with plug fans and scroll compressors
Cooling capacity 30135kW
Heating capacity 29142kW

R410A

HANDLING SECTION WITH PLUG FANS COUPLED WITH BRUSHLESS EC MOTORS


THERMODYNAMIC HEAT RECOVERY
FREE-COOLING OPERATION
FOR HIGH CROWDING APPLICATIONS

Features
Independent Roof-top type air conditioner for treatment, filtration and renewal of the air, based on
the chosen configuration. RTY units are designed
for high crowding applications, such as cinemas,
conference rooms, restaurants, nightclubs being
intended for operation with 80% external and
expelled air .
The standard unit allows to manage the cooling
operation and the recovery of the energy contained in the exhaust air allowing higher performances and efficiencies.
Versions
RTY_H
heat pumps

Configurations
MB3
with mixing chamber with three dampers,
return fan and heat recovery from expelled
air.
The configuration can be further customized with a
wide choice of accessories
1 refrigerant circuit
High efficiency scroll compressors (tandem
UNEVEN) and low power consumption
Finned exchangers of the refrigerant circuit direct
expansion.
Supply and return fans, of plug fan type (EC). The
impellers are so oriented to ensure that the air
flow passes through all the internal components,
with the minimum noise.
Group of axial fans for extremely silent operation

placed on the condensing section.


Electronic control of condensation and evaporation are standard to extend further the
operating limits of the unit.
G4 air filter on the flow of outside air and on
the recovery; they are installed upstream of
the components, to ensure low pressure
drops.
Microprocessor control can handle the different modes of operation ensuring maximum
energy savings in any conditions C
Interfaces for connections to remote control
supervision system, available as optional.

BE: Electric heating coil 2 stages (not available


with hot air generator)
BEM: Modulating electric heating coil (not available with hot air generator)
BPGC: After heating coil with hot gas .
AXEC: Axial fans with EC motors with speed
control function according to the pressure of
condensation and evaporation.
MAN: High and low pressure gauges
U: installed steam ramp
UP: Immersed electrode producer standard supplied and installed steam ramp
CUR: Humidication control (Humidity probe
in recovery , limit humidity probe in supply, contact ON/OFF and modulating analog output)
DP: Dehumidication control (humidity probe
in recovery) and of after-heating (if present)
SCO2: Probe CO2
SVOC: Probe VOC
STA: Room temperature probe
SUA: Room humidity probe
RF: Smoke detector
RFC: Smoke detector and recirculation damper

closure management and external air intake


PR1: Remote control panel
SCMRM: Modulating servo-controls with spring
return
CA: Waterproof headphones on external air
intake
CF: Flue pipe (only on version with gas burner
module)
GP: Protection grille for external coils
VT: antivibration mounts
MSSM: Delivery silencers forms (only for rear air
delivery)
MSSR: Recovery silencers forms (only for rear air
delivery)

Accessories and fittings

SSV: Supervision system


RS: Serial card BMS RS485
LW:Interface card LonWorks
BIP: Interface card Ethernet-pCOweb (BACNET
IP)
BAC: interface card BACnet MS/TP pCOnet
FTH: Enthalpic free-cooling
PSTEP: Adjusting constant ow, step ow in function of the modulation of the cooling circuit
FT7: pocket lters F7 efciency placed on the
ow of supply air.
FT9: Pocket lters F9 efciency placed on the
ow of supply air
H10: Electronic lters placed on the ow of
supply air.
PSF2: Differential pressure switch signaling
fouled lters of recovery, renewal and discharge
Gx: Heating module with gas burner
BW: 2-rows heating coil with hot water
BWV2V: 2-rows heating coil with with hot water,
with 2-way modulating valve.
BWV3V: 2-rows heating coil with hot water, with
3-way modulating valve.

172

NOTE: for more details on accessories and


equipment, please refer to the technical handbook.

Features and technological advantages


RTY units have been designed with the aim of
reducing energy consumption that dictated the
result of technological choices present on the unit
that we briefly present.

HIGH EFFICIENCY VENTILATION


Ventilation is one of the major factors of
power consumption, for this reason particular
attention has been given to the study and the
construction of the ventilation system.
Fans type plug-fans with brushless EC motors
have been used in both supply and recovery;
they enables high performances and low
power consumption; also comparing them to
conventional centrifugal fans, they have no
belts or pulleys allowing easy flow regulation, compactness, versatility and ease of
maintenance.
A particular adaptive logic allows to adjust
the air flow to the actual demand of the
system with more consequent advantages in
terms of reduction of consumption.

Axial fans for the external section of the unit


are of helycal type; the electronic control of
condensation is standard and it regulates the
fan speed according to the load required,
allowing a noise reduction.
As an option, the motors can be electronically controlled (EC) for the reduction in consumption of the condenser section.

Configuration with thermodynamic recovery "MB3"

2
3
4

Plugfan supply and recovery


Axial fans
Tandem scroll compressors
Thermodynamic recovery EX exhaust air

MAXIMUM SEASONAL EFFICIENCIES


To improve the efficiency of the refrigerant
circuit, we have used scroll tandem compressors with different power between them
(compressors UNEVEN except for size 08.
This feature allows a reduction of consumptions and a better adaptability to the
demands of the system, especially in the operation at partial loads, ensuring higher seasonal efficiency .

Particular attention has been given naturally


also to the quality of air in the room, entrusted to the standard filters with G4 efficiency
on the flow of outside air, also available on
the recovery (optional) for process applications.
They are also available as an (optional) compact filters F7 and F9 or electronic H10 on
the flow of fresh air.

ACTIVE THERMODYNAMIC RECOVERY


It is also available a thermodynamic recovery
for the recovery of the energy contained in
the exhaust air in such a way that the flow of
exhaust air invests the external finned heat
exchanger, allowing higher performances and
efficiencies.

Of course all these technological advantages are


controlled by a temperature control of the latest
generation, able to handle the different modes of
operation; ensuring maximum energy savings in all
operating conditions by means of a special software.

173

Technical data
Mod. RTY Heat pump
Cooling capacity
Sensitive cooling capacity
Compressors input power
EER
Cooling capacity
Sensitive cooling capacity
Compressors input power
EER
Heating capacity
Compressors input power
COP

(1)

(2)

(3)

kW
kW
kW
W/W
kW
kW
kW
W/W
kW
kW
W/W

01
30,0
21,2
5,4
5,6
31,7
18,9
5,4
5,9
29,1
4,6
6,4

02
39,2
26,9
8,5
4,6
41,6
24,1
8,6
4,8
39,4
7,2
5,4

03
48,2
32,3
9,8
4,9
51,0
29,2
10,0
5,1
48
8,7
5,5

04
64,2
42,1
13,2
4,9
68,0
38,1
13,3
5,1
65,9
13,1
5,0

05
73,6
47,6
15,2
4,8
78,0
43,3
15,4
5,1
75,5
15
5,0

06
82,3
53,6
17,6
4,7
87,2
48,5
17,8
4,9
84,6
16,7
5,1

07
88,7
59,0
18,5
4,8
93,8
53,1
18,8
5
90
16,5
5,5

08
110,7
75,1
24,0
4,6
116,5
67,2
24,4
4,8
114,2
19,8
5,8

09
122,4
81,5
27,1
4,5
129,1
73,2
27,7
4,7
126,8
22,9
5,5

10
134,8
88,5
32,0
4,2
142,0
79,9
32,6
4,4
142,2
26,8
5,3

09

10

Cooling
(1) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 24C b.u. (EN14511); Operating with 80% external and expelled air
(2) Internal temperature 27C b.s., 19C b.u.; External temperature 35C b.s., 26C b.u.; Operating with 80% external and expelled air
Heating
(3) Internal temperature 20C b.s., 15C b.u.; External temperature 7C b.s. 6C b.u. (EN14511); Operating with 80% external and expelled air

01

02

03

04

05

type
n

%
type

1
500

1
560

1
630

2
450

1
500
11500
8050
462
291

2
450
14000
9800
623
298

2
450
15000
10500
464
301

2
450
16500
11550
772
306

GENERAL DATA
Compressors
Compressors
Circuits
Capacity steps
Refrigerant gas
Fans

(3)

External fans

Internal fans of flow

Internal fans of recovery

Air flow of inside fan


Available static pressure of supply
Available static pressure of recovery
Power supply

nom/max
min
(4) max
(4) max

type
n
type
n
mm
type
n
mm
m3/h
m3/h
Pa
Pa
V/ph/Hz

06

07

scroll

R410A
Axial AC
1

2
RAD EC

1
315

1
315

1
350

1
450

1
350
3500
2450
1376
279

1
400
4500
3150
1007
281

1
400
5500
3850
722
283

1
450
7000
4900
475
282

1
1
450
450
RAD EC
1
1
450
500
8000
9500
5600
6650
688
644
283
286
400V/3/50Hz

(3) Sizes 08 don't have UNEVEN compressors


(4) At the nominal/maximum flow rate, G4 medium fouling filter
Sound pressure
Sound pressure measured in free field, (1m, Q=2) away from the external surface of the ducted unit, available static pressure 300Pa at a nominal flow
(in accordance with the UNI EN ISO 3744).
Note: For more informations please refer to the technical documentation available on the website www.aermec.com

174

08

Dimensional data (mm)

40

40

Mod. RTY
Height
Width
Depth
Empty weight

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers.
All
All
All

01

02

03

04

05

06

07

08

09

10

2061
1900
3400
c.s.

2061
1900
3400
c.s.

2061
1900
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

2373
2100
3400
c.s.

Cod.: SRTYUY.00 /1401

c.s. please contact head office

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

175

RTE

ROOF-TOP cooling only and heat pump unit


Cooling capacities from 11,3 up to 55,9 kW
Heating capacities from 11,5 up to 55,70 kW

Features
The RTE rooftop units represent the ideal
solution for air conditioning medium-small
applications for tertiary and commercial use.
The units offer noteworthy advantages in terms
of air quality and environmental comfort, easy
installation and low noise level.
The availability of many accessories also confers
great versatility, thus making the range perfectly
suitable for the varied system requirements.
They are reversible air-cooled, used in winter
and summer, scroll compressors with R410A
refrigerant fluid.

Handling section fans:


for sizes 025, 030, 040, 050, the fans are the
centrifugal double intake type directly coupled
with the electronic device for variation of the
number of revs
as per standard. For sizes 080, 090, 100, 150,
200 the fans are the double intake centrifugal
type coupled using belts and pulleys with
variable pitch.

with copper pipes and high efficiency


aluminium louvers. Air filtering using synthetic
pleated filters with G4 efficiency (EN779).
Microprocessor adjustment
complete with electric control board, probes
and actuators for all components.
models available
RTE F
Cooling only version.

The direction of delivery air flow can be:


RTE 020...050
RTE H
- Rear
Heat pump version.
RTE 080...200
Structure:
For 025, 030, 040, 050 sizes it is self-supporting - Rear / lower / upper
with simple aluminium alloy panelling with
isolation of the air handling section via closed Helical condensation section fans:
cell expanded polyethylene (density 30 kg/m3). statically and dynamically balanced helical
For 080, 090, 100, 150, 200 sizes it is self- type, protected electrically by magnet circuit
s u p p or t i n g w i t h i n t e r nal and exter nal breakers and mechanically by grids.
aluminium alloy sandwich-type panelling with
thickness of 25 mm and injected polyurethane Cooling circuit:
insulation (density 42 kg/m3) for the perimeter Fitted with scroll compressors that guarantee
panels and for the roof of the air handling low noise level and high efficiency thanks to the
use of R410A gas, internal and external coil
section.

176

Accessories
SM - Mixing chamber 2 dampers.
BRE - Electric coils.
Including damper servocontrols and rain-proof Electric coil. See the table below.
hoods.
TP - Pressure transducers.
SM3P - Mixing chamber 3 dampers.
As per standard on all heat pump models.
3-damper mixing chamber with return fan and rear
intake, including damper servocontrols, rain-proof DCPR - PRESSURE CONTROL device.
hoods and management of the free-cooling for tem- Extends the functioning range of the rooftop in the
perature.
summer cycle (minimum temperature of the external
air up to 10 C) and in the winter cycle in heat pump
SM3I - Mixing chamber 3 dampers.
mode (maximum temperature of the external air up to
3-damper mixing chamber with return fan and lower 25 C). Moreover, it makes functioning silent with
intake, including damper servocontrols, rain-proof partial loads. A regulation circuit board varies the
hoods and management of the free-cooling for tem- number of the motor condensing fan revs on the basis
perature.
of the condensation pressure, read by the relevant
transducers, thus guaranteeing correct power supply
SCSM - Mixing chamber 2 dampers.
of the thermostatic valve.
Including servocontrols with dampers spring return
and rain-proof hoods.
DP - dehumidification and post-heating kit.
Kit for management of dehumidification and postSCSM3P - Mixing chamber 3 dampers.
heating. It can be coupled with the PUC accessory
3-damper mixing chamber with return fan and rear (Humidification contact).
intake, including spring return servocontrols, dampers, rain-proof hoods and management of the free- FCH - enthalpy freecooling.
cooling for temperature.
Only for models from 100 to 200 and the 3-damper
mixing chamber, if present.
SCSM3I - Mixing chamber 3 dampers.
It can be coupled with:
3-damper mixing chamber with return fan and lower - the DP accessory (dehumidification and post-heaintake, including spring return servocontrols, dam- ting management kit) only in presence of the 3-shutpers, rain-proof hoods and management of the free- ter mixing chamber and water or electric coil.
cooling for temperature.
- the PUC accessory (Humidification contact) only
with 3-damper mixing chamber.
P - filters pressure switch.
puc - humidification contact
Only for 100, 150, 200 models.
BRT2 - 2 row water coils .
ON/OFF contact (normally open) for humidification
Water coils for two row heating.
consent. In this case, the unit is complete with one
humidity probe positioned in the environment air
BRT3 - 3 row water coils
return. A humidity probe is also supplied to be posiWater coil for three row post-heating.
tioned downstream from the humidification section.
Mod.
SM
SM3P
SM3I
SCSM
SCSM3P
SCSM3I
PF
BRT2
BRT3
BRE103 (4)
BRE106
BRE109
BRE107
BRE112
BRE118
BRE212
BRE218
BRE224
BRE236
TP
DCPR
DP
DP+FCH (1)
PUC+FCH (2)
PUC+DP (3)
FCH
PUC
SQA
PR2
GP
VT
AVX
RC

25

30

40

50

80

90

sqa Air quality probe.


Only for 100, 200 models.
PR2 - REMOTE panel.
Allows to control the rooftop at a distance.
GP - protection grid.
Protects the external coil from blows and to prevents
access to the underlying area where the compressors
and the chiller circuit are housed.
VT - Rubber anti-vibration mounts.
Rubber anti-vibration mounts. Select the VT model
from the compatibility table.
AVX - Spring anti-vibration mounts.
Spring anti-vibration mounts. Select the AVX model
from the compatibility table.
RC Roof-curb.
Only for models from 080 to 200.
Attention: The standard configuration control is
however able to manage the following accessories,
which can also be added at a later date, SM, PF, SSV
(supervisor), PR2, TP. For any other accessory, change
the electric control board.
Independently from the type of control, GP , VT, AVX,
RC can be supplied at a later date.

100

150

200

(1) Only if 3-damper mixing chamber and water or electric coil present.
(2) Only with 3-damper mixing chamber.
(3) Only if electric or water coil present.
(4) BRE103 = electric coils, the first indicates the stages, the last two characters indicate the power (e.g.: 1 stage, 3 kW).

177

Technical data
RTE F
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER

kW
kW
kW
W/W

25
11,3
6,8
2,4
4,71

30
13,2
8,2
2,9
4,55

40
17,2
10,3
3,2
5,38

50
20,9
12,4
3,8
5,50

80
25,5
15,7
5,4
4,72

90
29,7
18,8
6,2
4,79

100
39,7
24
8,1
4,90

150
48,8
29,6
10,7
4,56

200
55,9
32,8
11,8
4,74

RTE H
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP

kW
kW
kW
W/W
kW
kW
W/W

25
11,1
6,7
2,4
4,63
11,5
2,3
5,00

30
13,2
8,2
3
4,40
12,5
2,3
5,43

40
16,7
10,2
3,3
5,06
17,1
3,1
5,52

50
20,3
12,2
4
5,08
19,3
3,3
5,85

80
25,1
15,5
5,4
4,65
25,3
4,6
5,50

90
29,5
18,7
6,2
4,76
29,1
5,6
5,20

100
39,4
23,8
8,1
4,86
39,1
6,9
5,67

150
48,3
29,4
10,7
4,51
48,6
8,8
5,52

200
55,5
32,5
11,80
4,70
55,70
10,40
5,36

1.500
1.275
1.725

1.900
1.615
2.185

2.400
2.040
2.760

2.900
2.465
3.400

4.500
3.825
5.175

6.000
5.100
6.900

8.000
6.800
9.200

9.000
7.650
10.350

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
2

4
2

4
2

4
2

315
16,3
22,5

275
19,2
27

345
22,5
32,2

287
25,5
37,1

4.000
3.400
4.600
Scroll
1
1
Axial
1
2
G4
50
1
350
36,1
52,1

330
39
56,8

365
57
81,8

360
68,9
100,4

330
74,4
109,3

3/6/9

3/6/9

3/6/9

6/12/18

6/12/18

58

58

61

61

64
400/3+N/50

Nominal air ow rate internal fans


m3/h
Minimum air ow for the handling section m3/h
Maximum air ow for the handling section m3/h
type
Compressors
n
Cooling circuits
n
Fans
type
External fans
n
Internal fans
n
Air lters
type
Thickness
mm
Evaporator
type
Maximum available pressure
Pa
Water coil heating capacity *
Electric coil heating capacity
Sound pressure level
Electrical power supply V/Ph/Hz

kW
kW
dB(A)

12/18/24/36 12/18/24/36 12/18/24/36 12/18/24/36

64

67

67

67

* Room air 20C d.b., water 80/70C.


Cooling capacity
RH 50% (Twb 19C), Text 35C RH
50%; Operation with 30% of ambient
air and expelled (version with mixing
chamber with three dampers SM3).
Nominal air ow.

178

Heating capacity
Heating capacity Tin 20C RH 50%,
Text 7C RH 70%. Operation with 30%
of ambient air and expelled (version
with mixing chamber with three dampers SM3). Nominal air ow.

Sound pressure:
Sound pressure in free eld, at 10 m distance
from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensional data (mm)

025 - 030

RTE
Height
Width
Depth
RTE F weight
RTE H weight

040 - 050

A
B
C

mm
mm
mm
kg
kg

25
1.040
1.175
1.155
235
245

30
1.040
1.175
1.155
250
260

40
1.040
1.175
1.155
270
280

50
1.040
1.175
1.155
285
300

080 - 200

80
1.175
1.240
1.805
435
455

90
1.175
1.240
1.805
450
470

100
1.500
1.510
2.710
650
690

150
1.500
1.510
2.710
675
710

200
1.500
1.510
2.710
735
770

Code : SRTE025_200UY.02 /1301

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

179

RTE

ROOF-TOP cooling only and heat pump unit


Cooling capacities from 82,5 up to 152 kW standard version
Heating capacities from 77,5 up to 148 kW standard version

R410A

Features
The rooftop units in the RTE range represent the
ideal solution for air conditioning environments
with average cubage for tertiary, commercial
and industrial destination.
The units offer noteworthy advantages in terms
of air quality and environmental comfort, easy
installation and low noise level.
The use of ecological R410A fluid refrigerant
allows to increase the unit efficiency.
The availability of many accessories, e.g. the
cross flow recovery systems or the hot air generator with condensation, also confer a
noteworthy versatility, making the RTE range
perfectly suitable for the various system requirements.
Structure:
Self-supporting with external aluminium alloy
and internal galvanised steel sandwich-type
panelling with thickness of 50 mm and injected
polyurethane insulation (density 42 kg/m3) for
the air handling section.

Air handling section fan:


Double intake centrifugal type with blades
facing forwards for greater silence, coupled
using belts and pulleys with variable pitch.
The direction of delivery air flow can be:
UPWARDS, SIDEWAYS AND DOWNWARDS.

complete with electric control board, probes


and actuators for all components.

transducers, thus guaranteeing correct power


supply of the thermostatic valve.
TP - Pressure transducers (as per standard
on heat pumps) They show the high and low
pressures on the display, they manage activity
of the compressors and the valves during
defrosting and inhibit their functioning when
the pressures exceed the limits set.
RUB - Cocks on the liquid and pressing line
(cooling only version) Hermetic cocks with

manual closure positioned on the compressor


delivery and on the circuit liquid side
GP - Protection grids Protect the external
coils from blows and hail.
T1 - Right lateral air intake (only on SM2).
T2 - Left lateral air intake (only on SM2).
T3 - Rear air intake (only on SM2).
T4 - Lower air intake (only on SM2).
T5 - Right lateral air intake (only on SM2).
T6 - Left lateral air intake (only on SM2).

Versions:
RTPA F cooling only version.
RTPA H heat pump.
High temperature functioning (A)
Condensation section fans:
Silenced functioning (L)
Statically and dynamically balanced helical SET-UPS:
type, protected electrically by magnet circuit
breakers and mechanically by grids.
SMP mixing chamber 2 dampers with rear intake.
Cooling circuit:
SM2 mixing chamber 2 dampers with lateral/
Fitted with scroll compressors that guarantee lower intake.
low noise and high efficiency, complete with SM3 mixing chamber 3 dampers with free-cooresistances on the guard, internal and external ling.
coil with copper pipes and high efficiency alu- FT7 F7 (EN 779) efficiency rigid pocket filters.
minium louvers.
REC cross flow heat recovery units with intake
fan.
Air filtering:
Gxxx condensation hot air generator (72 kW, 92
Pleated synthetic filters with G4 efficiency or F7 kW or 150 kW).
rigid pocket filters (optional).
Microprocessor adjustment

Accessories
DCPR - Pressure control device Extends the
functioning range of the rooftop in the summer
cycle (minimum temperature of the external
air up to 10 C) and in the winter cycle in heat
pump mode (maximum temperature of the
external air up to 25 C). Moreover, it makes
functioning silent with partial loads. A regulation circuit board varies the number of the
motor condensing fan revs on the basis of the
condensation pressure, read by the relevant

180

AI - Lower intake (only on SM3).


PA4 - Rear air intake Return fan static pressure up to 300 Pa at nominal ow rate.
MA - Upper air delivery Upper air delivery,
delivery fan static pressure up to 200 Pa at
nominal air ow rate.
MA - Left air delivery Left air delivery,
delivery fan static pressure up to 200 Pa at
nominal air ow rate.
MD - Right air delivery Right air delivery,
delivery fan static pressure up to 200 Pa at
nominal air ow rate.
PM4 - Delivery fan static pressure up to 400
Pa Delivery fan static pressure up to 400 Pa at
nominal ow rate.
BTR - Water heating coil 2 row hot water
coil with 3-way modulating valve. They can
be managed in post-heating mode only with
DP accessories. They can be coupled with the
G72 or G92 generator.
BRE - Electric heating coil Electric heating
coil with two stages tted with twin safety
thermostat, one with automatic rearm and the
other with manual rearm. The powers proposed are 12, 18, 24 and 36 kW (or indicate the
power requested in the order phase).
They can be managed in post-heating mode
only with DP accessories. The BRE cannot be
coupled with the G72 or G92 generator.
PUC - Humidication control set-up. ON/
OFF contact (normally open) for humidication consent. In this case, the unit is complete
with humidity probe positioned in the envi-

ronment air return. A humidity probe is also


supplied to be positioned downstream from
the humidication section.
DP - Kit for management of dehumidication and post-heating The control will force
compressor functioning in order to dehumidify
the air to the set humidity set. If the water or
electric coil is present, post-heating can also
be managed. It can be coupled with the PUC
accessory (humidication contact).
SCS - Damper servocontrols for 2-damper
set-up Modulating servocontrols mounted
directly on the return and external dampers for
the management of fresh air.
SCSM - Damper servocontrols with spring
return for 2-damper set-up Servocontrols with
spring return mounted directly on the return
and external dampers for the management of
fresh air. In the event of blackout they close
the external air damper completely and completely open the fresh air damper.
SCM3 - Damper servocontrols with spring
return for 3-damper set-up. Servocontrols with
spring return mounted directly on the dampers
for management of freecooling as a replacement for the standard ones. In the event of
blackout they close the external air dampers
completely and completely open the fresh air
damper.
FCH - Enthalpy Free-cooling Only with
3-damper mixing chamber. Manages the ow
of external and return air, making reference to
their enthalpy values.

PR2 - Remote panel Allows to perform


rooftop control operations from a distance.
SSV - RS485 serial interface for supervision
Serial board necessary for the interface with
supervision systems.
SQA - Air quality probe. It analyses the
quality of the air on the basis of a SnO2 sensor
with VOC mixed gas, evaluating contamination by polluting gases. The presence of the
probe coupled to the rooftop allows:
- to set a sensitivity threshold depending on
the envisioned maximum contamination of
the air.
- the ventilation of the rooms only when necessary, thus guaranteeing energy saving.
TV2 - Power supply voltage 3/230V/50Hz.
TV3 - Power supply voltage 3/460V/60Hz.
VTR (3 - 5 - 7) - Anti-vibration mounts Rubber anti-vibration mounts.
PF - Filters dirtying pressure switch
BSP - Special coils Condensing coils with
copper pipes and pre-painted aluminium
louvers.
BSR - Special coils Condensing coils with
copper pipes and copper louvers.
BSS - Special coils Condensing coils with
copper pipes and tinned copper louvers.
NOTE: for further information refer to the
technical manual.

Accessories coupling
Version

Size 240 - 260 - 300 -350 - 400


cooling only (F)
Heat pump (H)
L (no 350 and A (no 350 and
L (no 350 and A (no 350 and
Functioning
std
std
400)
400)
400)
400)
DCPR
as per standard
as per standard

TP
as per standard as per standard as per standard

RUB

GP

T1 (1)

T2 (1)

T3

T4

T5 (1)

T6 (1)

AI

PA4

MA

MS (1)

MD (1)

PM4

BTR

BRE

PUC

DP

SCS

SCSM

SCM3

FCH

PR2

SSV

SQA

TV2

TV3

VTR3 (basic set-up)

VTR5 (for units from 5 to 7.1 m)

VTR7 (for units over 7.1 m)

PF

BSP

BSR

BSS

(1) Right or left direction refers to the direction of air flow inside the handling sections.

181

Technical data

RTE F
kW
kW
kW
W/W

240
82,5
50,2
16
5,16

260
94,2
61,8
18,9
4,98

Standard
300
109,7
66,6
23,6
4,65

350
137,9
77,8
28,6
4,82

400
152,1
83,1
33,9
4,49

High temperature (A)


240
260
300
83,7
96,6 116,1
50,2
61,6
67,7
16,5
18,8
23
5,07
5,14
5,05

Low noise (L)


240
260
300
74,1
89,1
109,3
45,9
59,3
66,3
17,5
21,6
24,6
4,23
4,13
4,44

Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP

kW
kW
kW
W/W
kW
kW
W/W

240
81,8
49,7
16
5,11
77,5
13,4
5,8

260
93,4
61,8
18,9
4,94
89,9
14,4
6,2

Standard
300
111,8
67,2
23,6
4,74
107,7
17,3
6,2

350
137
77,1
28,6
4,79
133
22,5
5,9

400
150
83,1
33,9
4,42
148
26,8
5,5

High temperature (A)


240
260
300
82,9
95,7 114,9
49,7
61,6
67,7
16,5
18,8
23
5,02
5,09
5,00
81,1
95,6 106,2
13,8
15,3
17,9
5,9
6,2
5,9

Low noise (L)


240
260
300
72,3
89,1
90,4
45,9
59,3
64,2
17,5
21,6
21,7
4,13
4,13
4,17
78
88,8
88,1
13,9
15
17,8
5,6
5,9
4,9

Nominal air ow rate internal fans


Minimum air ow for the handling section
Maximum air ow for the handling section

m3/h
m3/h
m3/h
Type
n
n
Type
n
m3/h
q.t
Pa
Type
mm
Type
kW

Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER
RTE H

Compressors
Cooling circuits
External fans
Nominal air ow rate
Internal fans
Maximum available pressure
Air lters
Thickness
Evaporator
Water coil heating capacity *
Gas heating module heating capacity
Sound pressure level
Electrical power supply V/Ph/Hz

12.000 17.000 20.000 22.000 23.000 12.000 17.000


10.400 14.800 17.400 19.100 19.550 10.400 14.800
14.100 20.000 23.500 23.500 23.500 14.100 20.000
Scroll
2
2
Axial
4
32.000 29.000 28.000 40.000 34.200 29.000 28.000
1
200
G4
50
4
140
179
200
213
219
140
179
72
92
92
92
92
72
92
kW
92
150
150
150
150
92
150
dB(A)
72
73
74
77
78
72
73
400/3+N/50

20.000 12.000 17.000 20.000


17.400 10.400 14.800 17.400
23.500 14.100 20.000 23.500

33.000 19.000 18.000 22.000

200
92
150
74

140
72
92
69

179
92
150
70

200
92
150
71

* Room air 20C d.b., water 80/70C.


Cooling capacity
RH 50% (Twb 19C), Text 35C RH
50%; Operation with 30% of ambient
air and expelled (version with mixing
chamber with three dampers SM3).
Nominal air ow.

182

Heating capacity
Heating capacity Tin 20C RH 50%,
Text 7C RH 70%. Operation with 30%
of ambient air and expelled (version
with mixing chamber with three dampers SM3). Nominal air ow.

Sound pressure:
Sound pressure in free eld, at 10 m distance
from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensional data (mm)

C
B

RTE
Height
Width
Depth
Weight RTE
Weight RTE H

A
B
C

mm
mm
mm
kg
kg

240
1.830
2.166
3.290
1300
1320

260
1.830
2.166
3.290
1390
1410

300
1.830
2.166
3.290
1480
1500

350
1.830
2.166
3.286
1.565
1.645

400
1.830
2.166
3.286
1.645
1.725

Code : SRTE240_400UY.01 /1301

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

183

RTE

ROOF-TOP cooling only and heat pump unit


Cooling capacities from 150 up to 254 kW standard version
Heating capacities from 151 up to 266 kW standard version

Features
The rooftop units in the RTE range represent the
ideal solution for air conditioning environments
with average and large cubage for tertiary, commercial and industrial destination.
The units offer noteworthy advantages in terms
of air quality and environmental comfort, easy
installation and low noise level.
The use of ecological R410A fluid refrigerant
allows to increase the unit efficiency.
The availability of many accessories, e.g. the
cross flow recovery systems or the hot air generator with condensation, also confer a
noteworthy versatility, making the RTE range
perfectly suitable for the various system requirements.

and pulleys with variable pitch.


The direction of delivery air flow can be: Versions:
UPWARDS, SIDEWAYS AND DOWNWARDS.
RTPA F cooling only version.
RTPA H heat pump.
Condensation section fans:
High temperature functioning (A)
Statically and dynamically balanced helical Silenced functioning (L)
type, protected electrically by magnet circuit SET-UPS:
breakers and mechanically by grids.
SMP mixing chamber 2 dampers with rear intaDouble cooling circuit:
ke.
which at the same time guarantees the respect SM2 mixing chamber 2 dampers with lateral/
for the environment and the increase of energy lower intake.
efficiency. The cooling circuit lines and the elec- SM3 mixing chamber 3 dampers with free-cootric plant wiring are inserted into the base of the ling.
machine with the purpose of making mainte- FT7 F7 (EN 779) efficiency rigid pocket filters.
nance and internal cleaning easier.
REC cross flow heat recovery units with intake
Structure:
Scroll tandem compressors that guarantee low fan.
Self-supporting with external aluminium alloy noise and high efficiency.
Gxxx condensation hot air generator.
and internal galvanised steel sandwich-type Internal and external coil with copper pipes and
panelling with thickness of 50 mm and injected high efficiency aluminium louvers.
polyurethane insulation (density 42 kg/m3) for
the air handling section.
Air filtering:
Pleated synthetic filters with G4 efficiency or F7
Air handling section fan:
rigid pocket filters (optional).
Double intake centrifugal type with blades Microprocessor adjustment
facing.
complete with electric control board, probes
forwards for greater silence, coupled using belts and actuators for all components.

Accessories
DCPR - Pressure control device (as per standard for
silenced functioning mode) Extends the functioning
range of the rooftop in the summer cycle (minimum
temperature of the external air up to 10 C) and in
the winter cycle in heat pump mode (maximum
temperature of the external air up to 25 C).
Moreover, it makes functioning silent with partial
loads. A regulation circuit board varies the number
of the motor condensing fan revs on the basis of the
condensation pressure, read by the relevant transducers, thus guaranteeing correct power supply of the

184

thermostatic valve.
GP - Protection grids Protect the external coils from
blows and hail.
T1 - Right lateral air intake (only on SM2).
T2 - Left lateral air intake (only on SM2).
T4 - Lower recirculation air intake. rear fresh air
intake (only on SM2).
T5 - Right lateral recirculation air intake. left fresh
air intake (only on SM2).
T6 - Left lateral recirculation air intake. right fresh
air intake (only on SM2).

AI - Lower intake (only on SM3).


PA4 - Rear air intake Return fan static pressure up to
300 Pa at nominal flow rate.
MA - Upper air delivery.
MS - Left air delivery nominal air flow rate.
MD - Right air delivery.
PM4 - Delivery fan static pressure up to 400.
Pa Static pressure of the delivery fan up to 400 Pa at
nominal flow rate.
BTR - Water heating coil 2 row hot water coil with
anti-freeze probe as per standard. They can be

managed in post-heating mode only with DP accessories. They can be coupled with the Gxxx generator.
V3V - 3-way valve with servocontrol modulating for
the management of the water coil mounted inside
the rooftop
BRE - Electric heating coil Electric heating coil with
two stages fitted with twin safety thermostat, one
with automatic rearm and the other with manual
rearm.
They can be managed in post-heating mode only
with DP accessories. The BRE cannot be coupled
with the Gxxx generator.
PUC - Humidification control set-up. ON/OFF contact (normally open) for humidification consent. In
this case, the unit is complete with humidity probe
positioned in the environment air return. A humidity
probe is also supplied to be positioned downstream
from the humidification section.
DP - Kit for management of dehumidification and
post-heating The control will force compressor functioning in order to dehumidify the air to the set
humidity set. If the water or electric coil is present,
post-heating can also be managed. It can be coupled with the PUC accessory (humidification contact).
SCSR - Recirculation damper for SMP mixing chamber.

Accessories coupling
Version
Functioning
DCPR
TP
GP
T1
T2
T4
T5
T6
AI
PA4
MA
PM4
BTR
V3V
BRE (1)
PUC
DP
SCSR
SRP
SCMP
SCS2
SR2
SCM2
SCM3
FCH
PR2
SSV
SQA
CAF
CF (only with Gxxx)
PF
RUB
VT

std

SRP - Recirculation damper for the SMP mixing


chamber and modulating servocontrol (joined dampers).
SCMP - Recirculation damper for the SMP mixing
chamber and modulating servocontrol with spring
return.
SCS2 - Recirculation damper for SM2 mixing chamber.
SR2 - Recirculation damper for the SM2 mixing
chamber and modulating servocontrol.
SCM2 - Recirculation damper for the SM2 mixing
chamber and modulating servocontrol on return and
modulating servocontrol with spring return on fresh
air.
SCM3 - Modulating servocontrols with spring control for SM3 or REC set-ups.
FCH - Enthalpy Free-cooling Only with 3-damper
mixing chamber. Manages the flow of external and
return air, making reference to their enthalpy values.
PR2 - Remote panel Allows to perform rooftop control operations from a distance.
SSV - RS485 serial interface for supervision Serial
board necessary for the interface with supervision
systems.
SQA - Air quality probe. It analyses the quality of
the air on the basis of a SnO2 sensor with VOC
mixed gas, evaluating contamination by polluting
gases. The presence of the probe coupled to the

rooftop allows:
- to set a sensitivity threshold depending on the envisioned maximum contamination of the air.
- the ventilation of the rooms only when necessary,
thus guaranteeing energy saving.
CAF - For protection of the external air inlets in the
mixing chambers with 2 dampers or recovery unit.
As per standard with SM3.
CF - Stainless steel flue, double isolated wall with
inspection cap and measuring sump with flue gas
temperature thermometer.
PF - Filters dirtying pressure switch.
RUB - Cocks on the liquid and pressing line (cooling only version).
NOTE: for further information refer to the technical
manual.

Size 480-530-600-700-800
cooling only (F)
Heat pumps (H)
L
A (no 700 - 800)
std
L
standard
standard

standard
standard

A (no 700 - 800)

standard

(1) Not available with Gxxx set-ups.

185

Technical data
RTE F
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER

kW
kW
kW
W/W

480
160,6
119,5
39,3
4,09

530
189,8
147,1
43,1
4,40

Standard
600
210,9
159,3
47
4,49

480
155,7
120,5
41,4
3,76
158,1
28,7
5,51
26.500
22.500
30.500

530
188,3
145,9
43,8
4,30
186,4
31,5
5,92
29.500
25.000
34.000

Standard
600
207,9
157,8
48,8
4,26
212,7
37
5,75
31.500
26.800
36.300

RTE H
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP
Nominal air ow rate internal fans
Minimum air ow for the handling section
Maximum air ow for the handling section
Compressors
Cooling circuits
External fans
Nominal air ow rate
Internal fans
Maximum available pressure
Air lters
Thickness
Evaporator
Sound pressure level
Electrical power supply V/Ph/Hz

kW
kW
kW
W/W
kW
kW
W/W
m3/h
m3/h
m3/h
Type
n
n
Type
n
m3/h
n
Pa
Type
mm
Type
dB(A)

74.600

72.400

69.200

3
82

4
83

4
84

480
157,6
123,7
40,7
3,87

530
189,3
147,2
42,9
4,41

480
154,4
119,1
42,6
3,62
157
28,6
5,49
26.500
22.500
30.500

530
188,3
145,9
43,8
4,30
186,7
31,5
5,93
29.500
25.000
34.000

RTE F
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER

kW
kW
kW
W/W

RTE H
Cooling capacity
Sensitive nominal cooling capacity
Compressor input power
EER
Heating capacity
Compressor input power
COP
Nominal air ow rate internal fans
Minimum air ow for the handling section
Maximum air ow for the handling section
Compressors
Cooling circuits
External fans
Nominal air ow rate
Internal fans
Maximum available pressure
Air lters
Thickness
Evaporator
Sound pressure level
Electrical power supply V/Ph/Hz
Cooling capacity
RH 50% (Twb 19C), Text 35C RH
50%; Operation with 30% of ambient
air and expelled (version with mixing
chamber with three dampers SM3).
Nominal air ow.

186

kW
kW
kW
W/W
kW
kW
W/W
m3/h
m3/h
m3/h
Type
n
n
Type
n
m3/h
n
Pa
Type
mm
Type
dB(A)

74.600

3
82

72.400

4
83

Silenziata L
600
215,6
160,3
45,1
4,78

700
247
184,5
58
4,26

800
274,4
201,5
69,9
3,93

700
800
245,8
272,2
183,1
201,2
59,1
70,9
4,16
3,84
242,2
278,8
49,2
60,4
4,92
4,62
35.000
38.500
29.800
32.700
40.300
44.300
Scroll tandem
4
2
Axial
4
84.400
80.600
1
200
G4
50
4
4
87
88
400/3/50

700
245,4
184,3
58,7
4,18

Standard
600
700
211,8
242,5
159,8
182,5
46,5
60,7
4,55
4,00
205,8
238,9
36,4
48,9
5,65
4,89
31.500
35.000
26.800
29.800
36.300
40.300
Scroll tandem
4
2
Axial
4
69.200
84.400
1
200
G4
50
4
4
84
87
400/3/50

Heating capacity
Heating capacity Tin 20C RH 50%,
Text 7C RH 70%. Operation with 30%
of ambient air and expelled (version
with mixing chamber with three dampers SM3). Nominal air ow.

High temperature (A)


480
530
600
167,3
195,6
223,6
123,3
149,6
150,5
36,9
40,9
45,1
4,53
4,78
4,96
High temperature (A)
480
530
600
163,7
190,5
219,3
122,8
147,4
158,8
37,5
42,4
47,6
4,37
4,49
4,61
167,3
191,6
217,2
29,5
31,8
36,9
5,67
6,03
5,89
26.500
29.500
31.500
22.500
25.000
26.800
30.500
34.000
36.300

72.400

69.200

67.400

4
82

4
83

4
84

800
268
199,6
73,3
3,66

800
266
198,7
74,6
3,57
262,8
58,5
4,49
38.500
32.700
44.300

80.600

4
88

Sound pressure:
Sound pressure in free eld, at 10 m distance
from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensional data (mm)

C
B

RTE
Height
Width
Depth
Depth RTE
Depth RTE H

A
B
C

mm
mm
mm
kg
kg

480
2450
2350
4200
2100
2200

530
2450
2350
4200
2200
2300

600
2.450
2.350
4.200
2300
2400

700
2.450
2.350
5.500
2700
2800

800
2450
2350
5500
2800
2900

Code : SRTE480_800UY.01 /1301

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

187



IDROBLOC

Air cooled chiller with axial fan


With capacity from 3.5 up to 6.7 kW

R407C
IDROBLOC is a low-consumption water chiller

off, without ever having to adjust the water distri-

assembly designed for outdoor installation, sized to


provide a water flow sufficient to run a relatively

bution circuit.
IDROBLOC may be installed on the ground or

high number of terminal units. The thermal head of


water to the evaporator can be contained to 2.5C;
in practical terms, this means that the system can
run fancoils in all rooms, though only operating the
ones located in rooms that are occupied. The user
can select which of the fancoils installed are to be
activated, simply by turning individual units on or

wall-mounted. With a size similar to that of regular


outdoor water boilers, the IDROBLOC is perfectly suited for new or restructured domestic
applications.

IDROBLOC
IDROBLOC H

Features
Unit for roof-hanging or floor-standing installation with brackets supplied (only for
IDROBLOC and IDROBLOC H)
All versions are supplied for use with R407C
Cooling only and heat pump version
Compact dimensions
Helical fan unit with axial delivery
Evaporator dimensioned for working with 't
= 2.5 C

Antifreeze electric heater for the storage tank


environments, keeping in operation only
Hydraulic circuit complete with pump,
those relative to rooms that are occupied
expansion tank, storage tank, water filter, flow Electric power used within the standard
switch and safety valve
domestic availability limits
Adjustment and control fully electronic with Extreme simplicity of installation
microprocessor card
Pre-arrangement for coupling with boiler,
with immediate seasonal switching
Possibility of powering the fan coils of all the

Accessories
DCPX: (only for IDROBLOC) Low temperatuand off, signalling of alarms and season chancable up to 150 m.
re device for correct cooling mode operation
geover). Can be made remote with shielded SDP: Electronic card for using PR3 accessory
with ambient temperatures from less than
cable up to 30 m.
up to a distance of 150 m.
20C down to - 10C.
PRD1: Smart remote panel. Repeats at a VT7: Anti-vibration mounts.
PR3: Simplified remote panel. Allows basic
distance the functions of the panel on the
machine checks to be carried out (turning on
machine. Can be made remote with shielded
Compatibility of accessories
IDROBLOC
3-5
3H-5H

DCPX 42

PR 3

PRD 1

SDP

VT 7

Installation
IDROBLOC is quick and simple to install: simply position the unit, then make all water and electrical connections.
The unit can be connected to any type of heating assembly: autonomous or centralised boiler, or district (remote) heating systems.

IDROBLOC Free-standing
DISTRICT HEATING
SYSTEM

IDROBLOC Wall-mounted

190

INDIPENDENT
HEATING SYSTEM

CENTRALIZED
HEATING SYSTEM

Technical data
IDROBLOC
Cooling capacity
Total input power*
Input current*
Evaporator water flow rate
Effective head
Heating capacity
Total input power*
Input current*
Evaporator water flow rate
Effective head
Sound pressure
Total air flow rate
Compressors
Peak current (compressor)
Storage tank capacity
Expansion tank capacity
Pump speed
Water connections (female Gas)

3
3,5
1,5
7,3
600
2000
69
32
33,5
1200
1

kW
kW
A
l/h (nominal)
l/h (max.)
kPa (nominal)
kPa (max.)
kW
kW
A
l/h (nominal)
l/h (max.)
kPa (nominal)
kPa (max.)
dB (A)
m3/h
n
type
A
l
l
n.
(installation)
(heating)

3H
3,2
1,5
7,3
550
2000
69
59
3,85
1,45
7,2
660
2000
67
55
33,5
1200
1
Scroll

33,5
25
1
3
3/4
1/2

33,5
25
1
3
3/4
1/2

Power supply = 230V ~ 50Hz.


Performance values refer to the following
conditions:
Cooling:
- water outlet temperature 7 C;
- ambient air temperature 35 C
- 't = 5 C.

Riscaldamento:
- water outlet temperature 50 C;
- ambient air temperature 7 C D.B., 6 C
W.B.
- 't = 5 C.

Sound pressure:
Sound pressure in free field, at 10 m distance
from the external surface of the unit (in
accordance with UNI EN ISO 3744)
* = included the absorption of the circulation
pump

Dimensions (mm)

A
B
C
Kg

3
990
450
450
79

3H
990
450
450
80
Cod.: SIDBUY.05 /1502

IDROBLOC
Height
Width
Depth
Weight

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

191

ANL
020/202

chillers, heat pumps and condensing units


Air/Water for outdoor installation
Axial fan and scroll compressor:
Cooling capacity 5,6543,70kW
Heating capacity 6,2744,64kW

R410A
Aermec
participates in the EUROVENT
Certification Programme: LCP
The products concerned appear in
the
EUROVENT
site
www.eurovent-certification.com.

Fans

STANDARD VERSION
VERSION WITH BUILT-IN HYDRONIC KIT
PRODUCTION OF HOT DOMESTIC WATER (D.H.W.)
Characteristics
Cooling only, heat pump, and condensing unit
models
Versions
ANL_: Chillers without hydronic kit
ANL_H: Heat pumps without hydronic kit
ANL C: Condensing unit
Versions with hydronic kit
ANL_P/HP: with standard pump
ANL_N/HN: with high pump
ANL_A/HA: with buffer tank and standard pump
ANL_Q/HQ: with buffer tank and high pump
Operational limits (1)
Cooling mode
- max. external air temperature 46C

Heating mode
- max. Leaving water temperature 50C
High efficiency scroll compressors with low
power input
flow switch/ pressure switch as standard supply
Water filter
High efficiency heat exchangers
Axial flow fan units for extremely quiet operation
Inverter axial flow fan units for heat pumps
from size 030H to 090H)
The hydronic kit includes:
- Expansion tank
- Safety valve

- Pressure gauge
Electronic controller (Modu_control)
Metallic protective cabinet with anti-corrosion polyester paint
(1) For more details on operating limits, refer to the
technical documentation available on the website
www.aermec.com

Accessories
MODU-485A: RS-485 interface for superviavailable:
SPLW: System water temperature sensor. In most
sion systems with MODBUS protocol.
cases the loose supplied sensors for each chiller/
AERWEB300: The AERWEB option allows
heat pump are sufficient. In cases of a common
remote control of a chiller through a standflow/return header this sensor can be used to conard PC and an ethernet connection with a
trol the common system supply water temperature
standard browser; 4 versions available:
for the chillers connected to the header, or it can
AERWEB300-6: Web server to monitor and
be used for temperature monitoring.
remote control maximum 6 units on RS485
SDHW: Domestic hot water temperature sensor.
network;
Used with the storage tank to control the temperaAERWEB300-18: Web server to monitor and
ture of water produced.
remote control maximum 18 units on RS485
VMF-CRP to predict accessory for the managenetwork;
ment of the probes SPLW / SDHW if provided
AERWEB300-6G: Web server to monitor and
with the MULTICONTROL
remote control maximum 6 units on RS485
PR3: Simplified remote panel. Permits control
network with integrated GPRS modem;
of the basic unit functions (on/off and change
AERWEB300-18G: Web server to monitor and
of operating mode, diagnostics and alarm
remote control maximum 18 units on RS485
reset). Maximum distance permitted is 150 m
network with integrated GPRS modem.
with screened cable.
MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fit- DCPX: an speed controller allowing operation in
ted with our MODUCONTROL controller and
cooling mode within an external temperature
installed in the same hydraulic system.
range from +20 C to -10 C;
For complete control the following accessories are
Standard for the version with desuperheater

192

BDX: Condensate drip tray with integrated


electric heater controlled by the external air
temperature sensor.
VT: Anti-vibration mounts.
Accessories factory fitted only
DRE: Electronic soft starter device reducing
starting current by about 30%
KR: Anti-freeze electric heater for the plate
heat exchanger, not available for sizes 020AHA to 040A-HA.
KRB:Electric anti-freeze heater for the base.
Prevents the formation of ice on the base.
RA: Anti-freeze electric heater for the buffer
tank.
Compatibility with the VMF system
For further system information please refer
to the specific documentation.

Accessory compatibility

ANL
MODU-485A
AERWEB300
MULTICONTROL
SPLW
SDHW

vers
All
All
All
All
All

020

025

030

040

050

070

080

090

102

152

202

VMF-CRP

All

PR3

All
() - C
H
() / P
A
() - H - HP - C
A - HA

50
51
5
5
9
9

50
51
5
5
9
9

50
5
5
9
9

50
5
5
9
9

50
5
6
9
15

50
5
6
9
15

50
5
6
9
15

50
5
6
9
15

52
53
15
15

52
53
15
15

52
53
15
15

5
2
2

5
2
2

5
2
2

5
2
2

5 x2
2
100

5 x2
2
100

5 x2
2
100

(1)
(2)

DCPX
BDX
VT
Accessories factory fitted only
DRE

(3)
/H/P/HP
A/HA

KR
KRB3
RA
RA100

A/HA

(1) Standard for the unit with desuperheater


(2) The heat pump ANL030H090H fitted as standard fans Inverter
(3) Only for puwer supply 400V/3N/50Hz

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system
requirements.
Field
1,2,3
4,5,6
7

10

11

12

13

Code
ANL
Size
020-025-030-040-050-070-080-090-102-152-202
Model
Only cooling
H Heat pump
Version
Standard
P With pumps
N With high pump (for size from 102 to 202)
A With buffer tank and standard pump
Q With buffer tank and high pump (for size from 050 to 202)
Heat recovery
Without recovery
D With desuperheater (4)
Coil n (5)
Aluminium
R Copper
S Tinned copper
V Treated aluminium
Field of use
Standard (leaving water temperature down to 4C)
Z Low leaving liquid (from 4C down to up to 0C) (6)
Y Low leaving liquid (from 0C down to -6C) (6)
Evaporator
Standatd
C Condensing unit
Power supply
M 230V/1/50Hz (for size from 020 to 040)
400V/3N/50Hz

(4) The desuperheater is available for sizes from 050 to 090 only with buffer tank, whilst sizes from 102 to 202 are available in all versions. Desuperheater is
incompatible with the low temperature options, with the condensing unit version, and for dimensional reasons even with the option Q.
(5) Coil fin options

Aluminium
R e S Only cooling model: only available for sizes 030-090; for sizes 020-025 treatment "R and D" is replaced by cataphoresis treatment
Models in heat pump: only for sizes 030H-202H
V
Cataphoresis treatment Cooling only available only for sizes 020 025 and 102 202; Models in heat pump: only for sizes 020 025
Epoxy paint for models with heat pump 020H 202H; for cooling only models 020 090(6) Option only in cooling model.
193
(6)
Options available only cooling version

Technical Data
Model
(1)
Cooling capacity

Total power input

EER

ESEER
Water flow rate
Total pressure drops
Available head

P|A
N|Q

P|A
N|Q

P|A
N|Q

P|A
N|Q
All

P|A
N|Q

kW
kW
kW
kW
kW
kW
W/W
W/W
W/W

l/h
kPa
kPa
kPa

020
5,65
5,71
1,89
1,92
3,00
2,98
3,43
3,5
980
21
60
-

025
6,15
6,21
2,05
2,07
3,00
3,00
3,43
3,54
1066
21
60
-

030
7,44
7,52
2,52
2,52
2,96
2,98
3,4
3,55
1290
22
59
-

040
9,53
9,64
3,32
3,30
2,87
2,92
3,33
3,48
1651
24
55
-

050
13,31
13,47
13,73
4,12
4,10
4,18
3,23
3,28
3,28
3,74
3,85
3,66
2305
25
82
160

070
16,39
16,59
16,9
4,98
4,92
5,01
3,29
3,37
3,37
3,82
3,97
3,77
2838
26
81
159

080
20,35
20,60
20,9
6,48
6,39
6,48
3,14
3,22
3,22
3,65
3,8
3,61
3526
34
69
144

090
22,14
22,40
22,72
6,79
6,69
6,79
3,26
3,35
3,35
3,71
3,95
3,75
3836
35
66
140

102
26,34
26,93
27,07
8,06
8,07
8,46
3,27
3,34
3,20
3,85
3,96
3,61
4575
58
84
140

152
32,69
33,48
33,7
10,31
10,53
10,58
3,17
3,18
3,18
3,99
3,94
3,74
5676
61
115
185

202
42,60
43,49
43,7
13,53
13,79
13,83
3,15
3,15
3,16
3,94
3,82
3,62
7396
68
90
158

025H
6,15
6,21
2,05
2,07
3,00
3,00
3,43
3,54
1066
21
60
7,08
6,98
2,20
2,19
3,22
3,19
1204
37
56
-

030H
7,44
7,52
2,52
2,52
2,96
2,98
3,4
3,55
1290
22
59
8,49
8,37
2,71
2,68
3,13
3,12
1445
37
55
-

040H
9,53
9,64
3,32
3,30
2,87
2,92
3,33
3,48
1651
24
55
10,70
10,56
3,28
3,23
3,26
3,27
1823
34
51
-

050H
13,31
13,47
13,73
4,12
4,10
4,18
3,23
3,28
3,28
3,74
3,85
3,66
2305
25
82
160
14,12
13,93
13,67
4,42
4,37
4,45
3,20
3,19
3,07
2408
34
82
159

070H
16,39
16,59
16,9
4,98
4,92
5,01
3,29
3,37
3,37
3,82
3,97
3,77
2838
26
81
159
17,44
17,20
16,92
5,04
4,95
5,04
3,46
3,48
3,36
2976
36
79
157

080H
20,35
20,60
20,9
6,48
6,39
6,48
3,14
3,22
3,22
3,65
3,8
3,61
3526
34
69
144
22,40
22,11
21,79
6,50
6,36
6,46
3,45
3,48
3,37
3818
48
65
137

090H
22,14
22,40
22,72
6,79
6,69
6,79
3,26
3,35
3,35
3,71
3,95
3,75
3836
35
66
140
24,46
24,10
23,77
7,11
6,91
7,02
3,44
3,49
3,39
4162
65
61
132

102H
26,34
26,93
27,07
8,06
8,07
8,46
3,27
3,34
3,20
3,85
3,96
3,61
4575
58
84
140
29,31
28,69
28,56
8,87
8,87
9,30
3,30
3,23
3,07
4988
69
70
117

152H
32,69
33,48
33,7
10,31
10,53
10,58
3,17
3,18
3,18
3,99
3,94
3,74
5676
61
115
185
35,35
34,55
34,34
10,45
10,67
10,72
3,38
3,24
3,20
6020
68
100
174

202H
42,60
43,49
43,7
13,53
13,79
13,83
3,15
3,15
3,16
3,94
3,82
3,62
7396
68
90
158
45,78
44,90
44,64
13,78
14,06
14,08
3,32
3,19
3,17
7795
78
68
141

Cooling: (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
(1) 230V/1/50Hz = 400V/3N/50Hz

Model
(1)
Cooling capacity

Total power input

EER

ESEER
Water flow rate
Total pressure drops
Available head
(1)
Heating capacity

Total power input

COP
Water flow rate
Total pressure drops

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

P/A
N/Q

Available head

kW
kW
kW
kW
kW
kW
W/W
W/W
W/W

l/h
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
l/h
kPa
kPa
kPa

020H
5,65
5,71
1,89
1,92
3,00
2,98
3,43
3,5
980
21
60
6,27
6,19
1,98
1,98
3,17
3,12
1066
33
58
-

Cooling: (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating: (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
(1) 230V/1/50Hz = 400V/3N/50Hz

Cooling capacity
Total power input
EER
Connections
Gas line
Liquid line

(1)

Cooling:
Evaporating temperature 5C; External air temperature 35C
(1) 230V/1/50Hz = 400V/3N/50Hz

194

kW
kW
W/W

020C
5,7
1,85
3,08

025C
6,0
2,05
2,93

030C
7,5
2,5
3,00

040C
9,6
3,3
2,91

050C
13,7
4,1
3,34

070C
16,8
5,0
3,36

080C
20,8
6,5
3,20

090C
22,5
6,8
3,31

102C
26,9
8,6
3,13

152C
33,4
10,2
3,27

202C
43,7
14,10
3,10

15,88
9,52

15,88
9,52

15,88
12,7

15,88
12,7

22
15,88

22
15,88

22
15,88

28
15,88

28
15,88

28
15,88

28
15,88

Technical Data
DATA FOR ALL VERSIONS
Electrical data
Total input current
cooling mode
Total input current
heating mode
Maximum current (FLA)
Starting current (LRA)

(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N

020

025

030

040

050

070

080

090

102

152

202

A
A
A
A
A
A
A
A

6,43
3,7
6,61
3,80
16,5
6,0
59,5
26,5

7,3
4,2
7,65
4,40
16,5
6,0
62,5
32,5

8,17
4,7
9,39
5,40
19,7
6,7
83,7
35,7

10,78
6,2
11,83
6,80
23,7
8,7
98,7
48,7

8,7
9,50
11,3
65,3

9,7
10,30
13,5
75,3

12,2
12,90
16,3
102,3

12,8
13,80
17,3
96,3

15,57
17,00
22,0
76,0

18,81
19,00
26,0
87,0

24,67
25,00
32,0
117,0

type
n
n
%
type

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
scroll
scroll
scroll
1
2
2
2
1
1
1
1
0-100 0-50-100 0-50-100 0-50-100
R410A R410A R410A R410A

type
n

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

plate
1
1"

type
n
m3/h

axial
1
2500

axial
1
2500

axial
1
3500

axial
1
3500

axial
2
7200

axial
2
7200

axial
2
7300

axial
2
7200

axial
2
14000

axial
2
13500

axial
2
13500

Compressors
Compressors
Circuits
Capacity control
Refrigerant
System side exchanger
Exchanger
hydraulic connections
Fans standard

(in/out)

Fans
Air flow rate cooling mode
Sound data
Sound pressure
Sound power

dB(A)
30
30
37
37
38
38
38
37
44
45
46
dB(A)
61
61
68
68
69
69
69
68
76
77
78
V/ph/Hz 230V/1 230V/1 230V/1 230V/1
V/ph/Hz 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N

Power supply

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
(2) Unit in standard configuration/execution without hydroni kit
Nota: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
C

020
025
030
040
050
070
080
090
868
868
1000
1000
1252
1252
1252
1252
mm
868
868
1015
1015
1281
1281
1281
1281
mm
1281
1281
1281
1281
mm
900
900
900
900
1124
1124
1124
1124
mm
1124
1124
1124
1165
1165
1165
1165
mm 1124
1165
1165
1165
1165
mm
mm 310/354* 310/354* 310/354* 310/354* 384/428* 384/428* 384/428* 384/428*
550
550
550
mm 384/428* 384/428* 384/428* 384/428* 550
550
550
550
550
mm
kg
kg
kg
kg
kg
kg
kg
kg
kg

102

152

202

1450

1450

1450

1750

1750

1750

020 040 * ithut eet / ith eet


C

750

750

750
A

75

75

86

86

120

120

120

156

270

293

329

77

77

91

91

127

127

163

163

288

314

350

99

99

103

103

147

147

147

183

151

151

187

187

338

364

400

70

70

78

78

110

110

141

141

270

293

329

75

75

86

86

120

120

120

156

295

322

358

77

77

91

91

127

127

163

163

313

343

379

99

99

103

103

147

147

147

183

363

393

429

151

151

187

187

423

447

457

050 090
B
A

Cod.: SANLUY.17/1502

|P|C
A
Height (A)
Q
|P|C
Width (B)
A
Q
|P|C
Depth (C)
A
Q
Chillers (only cooling)

P
A
Weight
Q
C
Heat pumps

P
Weight
A
Q

102 - 152 - 202

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

195

ANL
290/650

Chillers
Air/Water outdoor installation
Axial fans and scroll compressor
Cooling capacity 55133kW

cooling only

R410A
Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

STANDARD VERSION
VERSION WITH INTEGRATED HYDRONIC MODULE
Features
Cooling versions and condensing unit
Versioni
ANL_ standard versions.
ANL_L Low noise versions.
ANL_C Condensing versions
ANL_CL Condensing low noise versions
High efficiency scroll compressors.
Flow switch as standard supply.
Water filter.

Low and high pressure transducers as standard supply.


High efficiency exchangers.
Axial fans with low sound level.
Possibility of integrated hydronic module user
side:
- Buffer tank and pumps, or pumps only
- Expansion tank
- Safety valve

- Pressure gauge
- Drain valve
Electronic controller (Modu_control).
Microprocessor control system
Metallic protective cabinet with anti-corrosion polyester paint.

MULTICONTROL: Allows the simultaneous


control of several chillers or heat pumps (up
to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following
accessories are available:
SPLW: System water temperature sensor. In
most cases the loose supplied sensors for
each chiller/heat pump are sufficient. In cases
of a common flow/return header this sensor
can be used to control the common system
supply water temperature for the chillers connected to the header, or it can be used for
temperature monitoring.
DCPX: Low temperature device for correct
cooling mode operation with ambient temperatures from less than 10 C down to - 10 C.
PR3: Simplified remote panel. Permits control
of the basic unit functions (on/off and change
of operating mode, diagnostics and alarm
reset). Maximum distance permitted is 150 m
with screened cable.
GP: Protects the external coil from blows.
VT: Anti-vibration mounts.

Accessories can only be applied in the factory


RIF: Current rephaser. Connected in parallel
to the motor, it allows a reduction of the
absorbed current about 10%.
DRE: Current soft starter device (about 26%
for two-circuit-units).
Available only with power supply 400V/3N.

Accessories
MODU-485A: RS-485 interface for supervision systems with MODBUS protocol.
AERSET: accessory allows the automatic
compensation of the operating setpoint of the
unit to which it is connected, based on a
0-10V MODBUS input signal.
Mandatory accessory:
- AER485 or MODU-485A
AERWEB300: The AERWEB option allows
remote control of a chiller through a standard PC and an ethernet connection with a
standard browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control maximum 6 units on RS485
network;
AERWEB300-18: Web server to monitor and
remote control maximum 18 units on RS485
network;
AERWEB300-6G: Web server to monitor and
remote control maximum 6 units on RS485
network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and
remote control maximum 18 units on RS485
network with integrated GPRS modem.

196

COMPATIBILITY WITH THE VMF SYSTEM.


For further system information please refer to
the specific documentation.

Accessory compatibility
ANL
MODU-485A
AERWEB300
MULTICONTROL
SPLW
AERSET
PR3
DCPX (version with standard fan "" Standard)

(1)

DCPX (version with high static pressure fan "M")


GP
VT (00)
VT (P1-P2-P3-P4)
VT (01-02-03-04)
Accessories can only be applied in the factory
RIF

Alls
Alls
Alls
Alls
Alls
Alls

L
Alls
Alls
Alls
Alls

290

300

340

62
GP3
17
13
13

62
GP3
17
13
13

62
GP3
17
13
13

Alls

32

32

42

400

63
GP3
17
17
13

580

83
standard
83
83
GP2 (x2)
11
11
11

620

83
standard
83
83
GP2 (x2)
11
11
11

650

83
standard
83
83
GP2 (x2)
11
11
11

42

50

72

51

inverter fans

(1) Standard for chillers with desuperheater


(1) standard for version "L" only for size 580650
(2) Only for power supply 400V/3N/50Hz
(x2) indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system
requirements.

Field
1,2,3
4,5,6
7

Description
ANL
Size
290-300-340-400-580-620-650
Field of use
Standard with produced water down to +4 C
Y Low leaving water up to -6 C (3)
X

10

11

Electronic thermostatic valve temperature of water produced


up to +4C (for different temperatures please contact us) (3)

Model
Only cooling
C Condensing unit
Heat recovery
Without heat recovery
D Desuperheater
Version
Standard
L Low noise versions
Coil
Aluminium
R Copper
S Tinned copper
V Coated

12

fans (4)
Standard
M increased
J Inverter
13
Power supply
400V/3N/50Hz
14
Soft-start
Without Soft Start
S With Soft Start
15-16
Integrated hydronic module user side
00 Without hydronic module
01 n 1 Low head pump and buffer tank
02 n 2 Low head pumps and buffer tank
03 n 1 high head pump and buffer tank
04 n 2 high head pumps and buffer tank
P1 n 1 Low head pump
P2 n 2 Low head pumps
P3 n 1 high head pump
P4 n 2 high head pumps

(2) Sizes up 290 to 400 are available only in the low noise mode "L"
(3) "D" option is not compatible with "Y" valve.
(4) On / off fan Standard, standard sizes up 580 to 650
On / off fan increased, option available for all sizes
Fans Inverter, standard sizes from 290 to 400, with no static pressure
Fans Inverter, option for sizes from 580 to 650 with static pressure

197

Technical data
Model
Cooling capacity
Total power input
EER
ESEER
Water flow rate
Total pressure drop
Usefoul head
Usefoul head

01-02
P1-P2
03-04
P3-P4

kW
kW
kW
kW
W/W
W/W

l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

290
55
20,96
2,60
3,83
9422
28
123
162

300
60
22,99
2,60
3,83
10339
33
114
153

340
66
25,19
2,61
3,93
11388
40
103
179

400
76
29,88
2,54
3,83
13154
41
93
170

580
111
104
40,36
43,69
2,74
2,38
4,03
3,71
19205
18029
81
72
74
91
167
183

620
124
114
47,13
51,23
2,63
2,23
3,99
3,68
21472
19772
61
52
80
100
174
193

650
133
121
54,40
59,44
2,44
2,03
3,72
3,52
23013
20933
70
58
61
87
155
180

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C

Model

Cooling capacity
Total power input
EER

kW
kW
kW
kW
W/W
W/W

290C
55
20,7
2,66

300C
61
22,5
2,69

340C
67
24,8
2,69

400C
77
29,4
2,62

580C
115
108
39,6
39,5
2,91
2,73

620C
128
117
46,2
47,3
2,77
2,48

650C
138
126
53,4
54,9
2,59
2,30

28
22

35
22

35
22

42
28

42
28

42
28

54
35

290

300

340

400

580

620

650

38
49
130
99

41
53
131
101

46
58
162
123

55
69
183
140

70
74
85
262
198

82
87
99
308
230

94
101
112
320
242

2
1
0-50-100

2
1
0-50-100

2
1
0-50-100

scroll
2
1
0-50-100
R410A

2
1
0-50-100

2
1
0-50-100

2
1
0-50-100

type
n

1
2"

1
2"

1
2"

plate
1
2"

1
2"

1
2"

1
2"

type
n
m3/h

Axial
4
15600

Axial
4
15600

Axial
4
15600

Axial
6
20700

Axial
2
35900

Axial
2
35900

Axial
2
35900

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

41
73

41
73

42
74

43
75
400V/3N/50Hz

50
45
82
77

50
45
82
77

51
46
83
78

Connections
gas line
liquid line
Cooling:
Evaporating temperature 5C; External air temperature 35C

GENERAL DATA
Electrical data
Total input current
Maximum current (FLA)
Starting current (LRA)
Starting current with Soft Start
Compressor

(1)
(1)
(1)
(1)

type
n
n
%
type

Compressor
Circuit
capacity Control
Refrigerant
Exchanger user side
Exchanger
Water connections
Fans standard

(in/out)

Fans
Air flow
Sound data
Sound pressure level
Sound power level
Power supply

A
A
A
A

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
(1) The electrical data of the versions without hydronic module integrated

198

Dimensions (mm)

ANL/L/C 290-300-340

ANL/L/C 400

ANL/L/C 580-620-650

A
B
C

mm
mm
mm
Kg

/L/C
/L/C
/L/C
/L

ANL 290
1605
1100
2450
628

ANL 300
1605
1100
2450
636

ANL 340
1605
1100
2450
648

ANL 400
1605
1100
2450
666

ANL 580
1875
1100
3200
854

ANL 620
1875
1100
3200
925

ANL 650
1875
1100
3200
970

Cod.: SANL290_650UY.07/1502

Height
Width
Depth
Empty weight

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

199

ANL
290/650

Air cooled heat pump


Axial fans
Cooling capacity 53128kW
Heating capacity 61142kW

heat pump

R410A

Aermec
participate in the EUROVENT program: LCP
the products are present on the site
www.eurovent-certification.com

STANDARD VERSION
LOW NOISE VERSION
VERSION WITH BUILT-IN HYDRONIC KIT
Features

Heat pump models.


Monocircuit.
R410A gas.
Available in 2 version:
[] Standard ANL 400/650
[L] Low noise vesion ANL 290/650
High efficiency scroll compressors
Flow switch as standard supply.
Low and high pressure transducers as standard supply.
Cooling mode: ANL-H 290-400 up to 43C
Cooling mode: ANL-H 580-650 up to 44C
Heating mode: ANL-H 290-650 up to 50C
High efficiency exchangers.

Axial fans with low sound level.


Versions with hydronic kit.
Pump+Pump standby option controlled by
manual switch.
Electronic controller (Modu_control).
Metallic protective cabinet with anti-corrosion polyester paint.
Microprocessor control system
- Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature
- Summer condensation control with 0-10V
modulating signal depending on pressure,
compensated according to the outside air

temperature (with DCPX accessory)


Intelligent defrosting to decay of pressure.
Automatic rotation of compressors.
Load limiting safety control.
Automatic reset of alarms before total block.
Alarm history.

Accessories
MODU-485A: RS-485 interface for supervision systems with MODBUS protocol.
AERSET: accessory allows the automatic
compensation of the operating setpoint of the
unit to which it is connected, based on a
0-10V MODBUS input signal.
Mandatory accessory:
- AER485 or MODU-485A
AERWEB300: The AERWEB option allows
remote control of a chiller through a standard PC and an ethernet connection with a
standard browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control maximum 6 units on RS485
network;
AERWEB300-18: Web server to monitor and
remote control maximum 18 units on RS485
network;
AERWEB300-6G: Web server to monitor and
remote control maximum 6 units on RS485
network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and
remote control maximum 18 units on RS485
network with integrated GPRS modem.

200

MULTICONTROL: Allows the simultaneous


control of several chillers or heat pumps (up
to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic
system.
For complete control the following accessories are available:
SPLW: System water temperature sensor. In
most cases the loose supplied sensors for
each chiller/heat pump are sufficient. In cases
of a common flow/return header this sensor
can be used to control the common system
supply water temperature for the chillers connected to the header, or it can be used for
temperature monitoring.
DCPX: Low temperature device for correct
cooling mode operation with ambient temperatures from less than 10 C down to - 10 C.
PR3: Simplified remote panel. Permits control
of the basic unit functions (on/off and change
of operating mode, diagnostics and alarm
reset). Maximum distance permitted is 150 m
with screened cable.
GP: Protects the external coil from blows.

VT: Anti-vibration mounts.


Accessories can only be applied in the factory
RIF: Current rephaser. Connected in parallel
to the motor, it allows a reduction of the
absorbed current about 10%.
DRE: Current soft starter device (about 26%
for two-circuit-units).
Available only with power supply 400V/3N.
COMPATIBILITY WITH THE VMF SYSTEM.
For further system information please refer to
the specific documentation.

Accessory compatibility
ANL_H
MODU-485A
AERWEB-300
MULTICONTROL
SPLW
AERSET
PR3
DCPX (version with standard fan "")

(1)

DCPX (version increased fan "M")


GP
VT (00)
VT (P1-P2-P3-P4)
VT (01-02-03-04)
Accessories can only be applied in the factory
RIF

290

300

all
all
all
all
all
all
H
HL
H
HL
all
all
all
all

62
GP3
17
13
13

62
GP3
17
13
13

all

32

32

340

63
GP3
17
13
13

400

83
standard
GP2 (x2)
11
11
11

580

83
standard
GP2 (x2)
11
11
11

620

83
standard
GP2 (x2)
11
11
11

650

83
standard
GP2 (x2)
11
11
11

42

42

50

72

51

inverter fans

(1) Standard with desuperheater


(1) Standard for the size up 400HL to 650HL
(x2) indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system
requirements.

1,2,3

DESCRIPTION
ANL

4,5,6

SIZE

Code

13

14 SOFT START
Without Soft Start
S With Soft Start

290-300-340-400-580-620-650 (2)
7

FIELD OF USE

Standard with produced water down to +4 C


Y Low leaving water up to -6 C (3)
X Electronic thermostatic valve temperature of water produced
up to +4C (for different temperatures please contact us) (3)
8

MODEL
H Heat pump

HEAT RECOVERY

Without heat recovery


D With partial heat recovery (desuperheater)
10

15-16
00
01
02
03
04
P1
P2
P3
P4

SORAGE TANK/PUMP
Without pump or storage tank
Low head pump and buffer tank
Single and standby low head pump and buffer tank
Single high head pump and buffer tank
Single and standby high head pump and buffer tank
Low head pump
Single and standby low head pump
Single high head pump
Single and standby high head pump

VERSION
Standard (ANL 400-580-620-650)
L Low noise

11

COIL

R
S
V

12

POWER SUPPLY

400V-3N -50 Hz

Aluminium
Copper
Tinned copper
Coated

FAN (4)
Standard
M increased
J Inverter

(2) Sizes up 290 to 340 are available only in the Low noise mode "L".
(3) "D" option is not compatible with "Y" valve.
(4) On / off fan Standard, standard sizes up 400 to 650
Fans on/off Increased, options only for size up ANL290HL to 340HL
Fans Inverter, standard sizes from 290 to 340, with no static pressure
Fans Inverter, option for sizes from 400 to 650 with static pressure

201

Technical data
ANL Reversible heat pump

L
/L
/L
/L
/L
/L

290
53
20,91
9152
26
37
61
18,82
10407
32
34

300
57
23,86
9888
24
41
66
20,60
11372
29
36

340
66
24,52
11348
31
45
73
22,37
12431
35
42

400
83
78
28,98
30,58
14247
13466
29
26
52
54
90
28,44
15412
33
51

580
106
101
41,54
44,60
18292
17412
44
40
68
72
122
38,73
20902
55
63

620
122
116
43,30
46,47
21088
20089
53
48
70
75
134
42,07
22834
61
68

650
128
122
48,42
51,87
22291
21150
61
55
77
83
142
46,00
24176
70
74

2,53
3,80
3,23

2,40
3,69
3,22

2,68
4,15
3,25

2,85
2,55
4,06
3,64
3,16

2,55
2,26
3,74
3,31
3,16

2,82
2,50
4,06
3,60
3,17

2,66
2,36
3,93
3,48
3,08

400V-3N-50Hz (with thermomagnetic switches)


54
65
98
107
160
181
264
264

116
273

Cooling capacity

kW

Total power input

kW

Evaporator water flow rate

l/h

Total pressure drop

kPa

Total input current

Heating capacity
Total power input
Condenser water flow rate
Total pressure drop
Total input current
ENEGY INDEX

kW
kW
l/h
kPa
A

EER

W/W

ESEER

W/W

COP
POWER SUPPLY
Power supply
Maximum current (FLA)
Starting current (LRA)
IP PROTECTION
IP
GAS
Type
SCROLL COMPRESSOR (Scroll)
Compressor / Circuit
AXIAL FAN ()
Quantity

W/W

L
/L

V
A
A

/L
/L

44
126

47
128

/L

24

24

/L

n/n

/L

2/1

2/1

2/1

Cold air flow

m3/h

Heat air flow


EVAPORATORS (Plates)
Quantity
Hydraulic connection (VICTAULIC)
HYDRONIC KIT
Buffer tank
Expansion tank
Security valve
SOUND DATA

m3/h

/L

L
/L

4
17600
17000

4
17600
17000

/L
/L

1
2

l
n/l
bar

/L
/L
/L

Sound power

dB(A)

Sound pressure

dB(A)

DATA DECLARED IN ACCORDANCE WITH


UNI EN 14511: 2013

Sound power
Aermec determines sound power values on
the basis of measurements made in
accordance with UNI EN ISO 9614-2, as
required for Eurovent certification.

202

24

24

24

24

24

2/1

2/1

2/1

2/1

6
17200
16400

2
45800
32060
44400

2
45800
32060
44400

2
44600
31220
43000

2
44600
31220
43000

1
2

1
2

1
2

1
2

1
2

1
2

300
1/25
6

300
1/25
6

300
1/25
6

300
1/25
6

400
1/25
6

400
1/25
6

400
1/25
6

73,4
41,7

74,1
42,4

74,3
42,6

89,4
83,4
57,6
51,5

89,4
84,0
57,6
52,1

89,4
84,6
57,6
52,7

89,4
85,2
57,6
53,4

R410A

COOLING
Evaporator water inlet
Evaporator water outlet
External air temperature
't

12C
7C
35 C
5C

Sound pressure
Sound pressure in free field, at 10 m
distance from the external surface of the
unit (in accordance with UNI EN ISO 3744)

Heating
Evaporator water inlet
External air temperature
Evaporator water outlet
't

40C
7C
45C
5C

Dimensions (mm)

ANL-H 290-300

ANL-H 340

ANL-H 400-580-620-650

A
B
C

mm
mm
mm
Kg
Kg

290
1605
1100
2450
655
673

340
1605
1100
2450
684
703

400
1875
1100
2950
808
832

580
1875
1100
3200
902
926

620
1875
1100
3200
1008
1033

650
1875
1100
3200
1053
1078

Cod.: SANLH290_650UY.00/1301

Mod ANL_H
Height
Width
Depth
Empty weight "00"
Functioning weight "00"

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

203

ANLI
R410A

Reversible heat pumps inverter


Air/water outdoor installation.
Axial fans and scroll compressor
Cooling capacity 5,7029,43kW
Heating capacity 6,1031,7kW

Aermec
participates at EUROVENT program: LCP
The involved products can be found in the website
www.eurovent-certification.com

STANDARD VERSION
VERSION WITH BUILT-IN HYDRONIC KIT ON/OFF INVERTER
HIGH EFFICIENCY EVEN AT PART LOAD
PRODUCTION OF HOT DOMESTIC WATER (D.H.W.)
Features
Reversible Heat pumps units
Version
ANLI_H Heat pumps, without hydronic kit
Versions with hydronic kit
ANLI_HP with standard pump on/off
ANLI_HX with standard pump inverter
Operational limits (1)
- max. external air temperature 42C
- max. Leaving water temperature 60C
heating mode
Capable of variable water flow rates on primary
circuit (terminals with 2-way valves)
Perfect water temperature control even in
systems with low water content
Suitable for heat pump mode summer operation
to provide domestic hot water (DHW) with the
DCPX fan speed controller accessory (when
provided)
High efficiency scroll and Twin rotary
compressors with permanent magnet DC motors
of "high side" type (with high pressure casing),
designed for variable speed operation

Inverter pumps variable speed pump with water


side pressure transducer installed and unit
mounted microprocessor, capable of controlling
various operating modes:
Constant 'P: maintains constant pressure
differential between pump inlet and outlet;
pump speed reduces as terminal valves close
Variable 'P: reduces pressure differential with
flow reduction, in consideration of the pressure
reduction in the pipe-work system to the
terminals (recommended for larger pipe-work
systems)
Water filter, differential pressure switch,
depending on the model, fitted on all units.
High efficiency heat exchangers with trace heating
as standard
Axial flow fan units for extremely quiet operation
Inverter axial fan (for size up 040H to 080H)
Fitted with EMC filters
The built-in hydraulic kit includes the main water
circuit components
Controller:

- Aermec Modu_Control circuit board


- User interface with 6 soft-touch keys, 4 digit
display, 6 LEDs
- Control of the leaving water temperature with
PID algorithm
- Set-point compensation based on the external
air temperature
- Display of operating frequency
- Control of compressor ramp speed
- Auto-adaptive intelligent defrosting
- Condensing control in summer with a 0-10 V
modulating signal based on pressure and
compensated for external air temperature (with
DCPX accessory (when provided)
- Load limiting safety control by reducing
compressor speed
- High and low pressure transducers
- Automatic reset of alarms before tripping
- Alarms history

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
MODU-485A: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows remote
control of a chiller through a common PC and an
ethernet connection over a common browser; 4
versions available:

204

AERWEB300-6: Web server to monitor and remote


control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network

with integrated GPRS modem;


AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network
with integrated GPRS modem;
AERSET: accessory allows the automatic compensation of the operating set point of the unit
to which it is connected, based on a 0-10V

MODBUS input signal.


MULTICONTROL: Allows the simultaneous
control of several chillers or heat pumps (up to
4) fitted with our MODUCONTROL controller
and installed in the same hydraulic system.
For complete control the following accessories
are available:
SPLW: System water temperature sensor. In most
cases the loose supplied sensors for each chiller/
heat pump are sufficient. In cases of a common
flow/return header this sensor can be used to
control the common system supply water temperature for the chillers connected to the header,
or it can be used for temperature monitoring.
SDHW: Domestic hot water temperature sensor. Used with the storage tank to control the
temperature of water produced.
VMF-CRP to predict accessory for the manage-

ment of the probes SPLW / SDHW if provided


with the MULTICONTROL
PR3: Simplified remote panel. Allows to perform
the basic controls of the unit with alarm signals.
It can be controlled with a shielded cable at a
distance up to 150 m.

BDX5: Condensate drip tray


Accessories factory fitted only
BDX8/9: Condensate drip tray with integrated electric heater controlled by the external
air temperature sensor.
KR: Electric anti-freeze resistance for plate
heat exchanger.
KRB: Electric anti-freeze resistance kit for
base; prevents the formation of ice on the
base.

DCPX: Allows correct operation, in cooling mode,


with outside temperatures lower than 20 C and as
low as 10 C, in heating mode up to 42 C.

BSKW: Electric heater kit with IP44 panel


for remote mounting in a sheltered area.
Available in single and three phase power
supply:
- BS4KW230M (4 kW, 230V/1/50Hz)
- BS6KW230M (6 kW, 230V/1/50Hz)
- BS6KW400T (6 kW, 400V/3/50Hz)
- BS9KW400T (9 kW, 400V/3/50Hz)
VT: Anti-vibration mounts.

COMPATIBILITY with VMF SYSTEM


For further information on system, refer to specific
documentation.

ANLI_H
MODU-485A
AERWEB300

vers
All
All

021

026

040

045

071

075

080

101

AERSET
MULTICONTROL
SPLW
SDHW

All
All
All
All

VMF-CRP
PR3
DCPX
VT
BS4KW230M
BS6KW230M
BS6KW400T
BS9KW400T
BDX
Accessories factory fitted only
BDX
KR
KRB

All
All
All
All
230V/1
230V/1
400V/3N
400V/3N
All

51
9

51
9

53
15

All
All
All

8
1

8
1

9
2

9
2

9
2

9
2

9
2

2
3

(1)

(1) The size ANLI040HANLI080H Inverter fans are fitted as standard

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
Code
1,2,3,4
ANLI
5,6,7
Size
021-026-040-045-071-075-080-101
8
Model
H Heat pump
9
Versions
Standard
P With ON/OFF pump
X With inverter pump
10
Heat recovery
Without heat recovery
11
Coil
Aluminium
R Copper
S Tinned copper
V In painted aluminium-copper (epoxy paint)
12
Field of use
Electronic expansion valve (leaving water temperature down to 4C)
contact head office for lower temperatures
13
Evaporator
Standard
14
Power supply
M 230V/1/50Hz (021-026-040-045)
T 400V/3N/50Hz

205

Technical Data
Model ANLI

Cooling capacity

Input power

EER

ESEER

Water flow rate


Pressure drops
Available head
Heating capacity

Input power

COP

Water flow rate


Pressure drops
Available head

021H
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX
H
HP
HX

kW
kW
kW
kW
kW
kW
W/W
W/W
W/W

l/h
l/h
l/h
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
l/h
l/h
l/h
kPa
kPa
kPa

5,71
5,75
5,79
1,94
1,98
1,91
2,95
2,91
3,03
4,15
4,11
4,38
987
987
987
11
67
74
6,23
6,18
6,14
1,93
1,97
1,90
3,23
3,14
3,23
1066
1066
1066
11
65
74

026H
7,26
7,33
7,37
2,58
2,59
2,53
2,82
2,83
2,92
4,10
4,29
4,54
1256
1256
1256
17
59
68
7,79
7,72
7,68
2,45
2,46
2,40
3,18
3,13
3,20
1331
1331
1331
18
58
67

040H
9,39
9,48
9,52
3,17
3,17
3,10
2,97
2,99
3,07
4,06
4,22
4,36
1622
1622
1622
12
62
72
9,92
9,82
9,78
3,17
3,16
3,09
3,13
3,11
3,16
1698
1698
1698
12
61
71

045H

071H

075H

080H

12,25
12,37
12,42
4,37
4,34
4,27
2,80
2,85
2,91
4,10
4,40
4,47
2119
2119
2119
20
50
61
12,75
12,62
12,57
4,23
4,19
4,12
3,02
3,01
3,05
2179
2179
2179
20
51
61

13,66
13,82
13,88
4,80
4,79
4,66
2,84
2,89
2,98
4,20
4,19
4,65
2363
2363
2363
18
92
82
15,16
14,99
14,94
4,85
4,82
4,70
3,13
3,11
3,18
2594
2594
2594
18
88
74

16,35
16,55
16,58
6,16
6,11
6,00
2,66
2,71
2,76
4,17
4,33
4,65
2831
2831
2831
25
82
61
17,60
17,39
17,38
6,07
6,01
5,92
2,90
2,89
2,94
3008
3008
3008
24
80
55

18,51
18,73
18,73
7,63
7,55
7,47
2,43
2,48
2,51
4,12
4,34
4,59
3207
3207
3207
32
73
42
20,12
19,89
19,91
7,27
7,19
7,13
2,77
2,77
2,79
3437
3437
3437
32
69
33

045H

071H

075H

080H

F1
28,77
29,43
29,43
11,73
11,82
11,82
2,45
2,49
2,49
4,11
4,40
4,40
4948
5061
5061
50

31,7
31,0
31,0
11,4
11,45
11,45
2,78
2,71
2,71
5452
5332
5332
59

101H
F2
23,95
24,53
24,53
8,14
8,31
8,31
2,94
2,95
2,95
4,11
4,40
4,40
4120
4219
4219
30
92
174
24,95
24,3
24,3
8,34
8,35
8,35
2,99
2,91
2,91
4291
4179
4179
36
85
167

F3
20,03
20,23
20,23
6
5,8
5,8
3,34
3,49
3,49
4,11
4,40
4,40
3445
3480
3480
24

20,08
19,54
19,54
6,36
6,38
6,38
3,16
3,06
3,06
3454
3362
3362
23

Cooling: (14511:2013)
Evaporator water temperature (in/out)12C/7C; Evaporator water temperature 35C
Heating: (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
(F1) maximum performance
(F2) performance compliant with french standard NF
(F3) Intermediate performance

Model

Heating capacity

Input power

COP

021H
H
HP
HX
H
HP
HX
H
HP
HX

kW
kW
kW
kW
kW
kW
W/W
W/W
W/W

6,58
6,52
6,48
1,63
1,66
1,59
4,03
3,93
4,07

026H
8,16
8,08
8,03
2,07
2,07
2,00
3,94
3,88
4,00

040H
10,51
10,41
10,37
2,68
2,67
2,60
3,92
3,90
3,99

Heating: (14511:2013)
Condenser water temperature (in/out) 30C/35C; External air temperature 7C b.s./6C b.u.
(F1) maximum performance
(F2) performance compliant with french standard NF
(F3) Intermediate performance

206

12,94
12,81
12,76
3,55
3,51
3,44
3,64
3,65
3,71

16,17
15,98
15,95
4,08
4,04
3,92
3,97
3,96
4,07

18,57
18,35
18,35
5,09
5,02
4,94
3,64
3,65
3,71

21,03
20,78
20,82
6,13
6,03
5,99
3,43
3,45
3,48

F1
33,75
33,01
33,01
9,85
9,86
9,86
3,43
3,35
3,35

101H
F2
25,34
24,65
24,65
7,05
7,06
7,06
3,59
3,49
3,49

F3
20,87
20,32
20,32
5,44
5,46
5,46
3,84
3,72
3,72

Technical Data
GENERAL DATA

021H

026H

040H

045H

071H

075H

080H
F1

101H
F2

F3

16,30
17,70
17,70
15,70
17,1
17,1
13,57
14,73
14,73
21,00
30,00

11,30
12,70
12,70
11,50
12,9
12,9
9,72
10,91
10,91
21,00
30,00

8,30
9,70
9,70
8,80
10,2
10,2
7,53
8,73
8,73
21,00
30,00

Electrical data
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(3)
(3)
(4)
(4)

Total input current


cooling mode
Total input current
heating mode
Total input current
heating mode
Maximum current (FLA)
Starting current (LRA)
Compressors

H
HP
HX
H
HP
HX
H
HP
HX
H
H

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger
Exchanger
hydraulic connections
Fans standard

(in/out)

fans
Air flow rate cooling mode
Sound data
Sound pressure
Sound power
Power supply

A
A
A
A
A
A
A
A
A
A
A

8,40
9,2
8,9
8,00
8,78
8,50
6,70
7,47
7,19
12,10
8,00

11,20
12,00
11,70
10,20
10,98
10,70
8,60
9,38
9,10
14,10
8,00

13,70
14,50
14,20
13,60
14,43
14,10
11,40
12,23
11,90
20,00
10,00

19,10
19,90
19,60
18,10
18,93
18,60
15,10
15,93
15,60
23,60
10,00

7,30
8,90
8,00
7,30
8,90
8,02
6,10
7,70
6,82
12,50
15,00

9,40
11,0
10,10
9,10
10,70
9,83
7,60
9,20
8,33
13,50
15,00

11,40
13,10
12,20
10,80
12,50
11,53
9,00
10,70
9,73
15,00
15,00

type
n
n
%
type

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100
R410A

scroll
1
1
0-100

type
n

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

type
n
m3/h

axial
1
3500

axial
1
3500

axial
2
8000

axial
2
8000

axial
2
7500

axial
2
7500

axial
2
7500

axial
2
13200

32,5
63,5
230V/1

35,7
66,7
230V/1

36,7
67,7
230V/1

36,7
67,7
400V/3

38,0
69,0
400V/3

38,0
69,0
400V/3

44,0
76,0
400V/3

dB(A)
31,0
dB(A)
62,0
V/ph/Hz 230V/1

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
(1) Evaporator water temperature (in/out)12C/7C; Evaporator water temperature 35C
(2) Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
(3) Condenser water temperature (in/out) 30C/35C; External air temperature 7C b.s./6C b.u.
(4) The electrical data of the versions without hydronic module integrated
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions and weight

021H - 026H

ANLI
Height
Width
Depth
Weight

(A)
(B)
(C)
H
HP|HX

mm
mm
mm
kg
kg

All
All
All

040H - 045H

021H
1028
1000
400
118
123

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

026H
1028
1000
400
118
123

071H - 075H - 080H

040H
1281
1000
450
138
143

045H
1281
1000
450
138
143

101H

071H
1281
1150
450
174
184

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

075H
1281
1150
450
174
184

080H
1281
1150
450
174
184

101H
1450
1750
750
293
308

207

Cod.: SANLIUY.14 /1501

ANK
R410A

Reversible heat pump Air/Water


Optimized for heating, outdoor installation
Axial fans, scroll compressor
Cooling capacity 6,8229,92kW
Heating capacity 7,9833,51kW

Aermec
participates in the EUROVENT
programme: LCP
The products involved can be found
at the website
www.eurovent-certification.com

STANDARD VERSION
VERSION WITH BUILT-IN HYDRONIC KIT
PRODUCTION OF HOT WATER UP TO 60 C
HEATING OPERATION WITH EXTERNAL
TEMPERATURES DOWN TO -20 C
PRODUCTION OF HOT DOMESTIC WATER WITH
EXTERNAL TEMPERATURES FROM -20 C UP TO 42 C
Characteristics
Reversible Heat pumps units
Versions
ANK H: Heat pumps high efficiency, without
hydronic kit
Versions with hydronic kit
ANK_HP: with standard pump
ANK HA: with buffer tank and standard pump
Operational limits (1)
- max. external air temperature 46C
cooling mode
- max. Leaving water temperature 60C

heating mode
High efficiency scroll compressors with low
power input
Electronic soft start to reduce starting current
(standard for single phase versions)
High efficiency heat exchangers with trace
heating as standard
flow switch as standard supply
Water filter
Axial flow fan units for extremely quiet operation

Inverter axial flow fan units for heat pumps


(ANK020HANK085H)
The hydronic kit includes:
- Expansion tank
- Safety valve
- Pressure gauge
Electronic controller (Modu_control)
Metallic protective cabinet with anti-corrosion polyester paint

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
MODU-485A: RS-485 interface for superviSPLW: System water temperature sensor. In most
AERWEB300-18: Web server to monitor and
cases the loose supplied sensors for each chiller/
remote control maximum 18 units on RS485
sion systems with MODBUS protocol.
heat pump are sufficient. In cases of a common
network;
AERSET
flow/return header this sensor can be used to conAERWEB300-6G: Web server to monitor and
The AERSET accessory allows the automatic
trol the common system supply water temperature
remote control maximum 6 units on RS485
compensation of the operating setpoint of the
for the chillers connected to the header, or it can
network with integrated GPRS modem;
unit to which it is connected, based on a
be used for temperature monitoring.
AERWEB300-18G: Web server to monitor and
0-10V MODBUS input signal. Mandatory
SDHW: Domestic hot water temperature sensor.
remote control maximum 18 units on RS485
accessory: AER485 or MODU-485A
Used with the storage tank to control the tempera AERWEB300: The AERWEB option allows
network with integrated GPRS modem.
ture of water produced.
remote control of a chiller through a stand- MULTICONTROL: Allows the simultaneous conVMF-CRP to predict accessory for the managetrol of several chillers or heat pumps (up to 4) fitard PC and an ethernet connection with a
ment of the probes SPLW / SDHW if provided
ted with our MODUCONTROL controller and
standard browser; 4 versions available:
with the MULTICONTROL
installed in the same hydraulic system.
AERWEB300-6: Web server to monitor and
For complete control the following accessories are PR3: Simplified remote panel. Permits control
remote control maximum 6 units on RS485
of the basic unit functions (on/off and change
available:
network;

208

of operating mode, diagnostics and alarm


reset). Maximum distance permitted is 150
m with screened cable.
DCPX: an speed controller allowing operation
in cooling mode within an external temperature
range from +20 C to -10 C; in heating mode in
summer to produce DHW with external temperatures up to +42 C.
BDX: Condensate drip tray with integrated
electric heater controlled by the external air

ANK
MODU-485A
AERSET
AERWEB300
MULTICONTROL
SPLW
SDHW
VMF-CRP
PR3
DCPX
BS4KW230M
BS6KW230M
BS6KW400T
BS9KW400T

temperature sensor.
BSKW: Electric heater kit with IP44 panel for
remote mounting in a sheltered area. Available
in single and three phase power supply:
- BS4KW230M (4 kW, 230V/1/50Hz)
- BS6KW230M (6 kW, 230V/1/50Hz)
- BS6KW400T (6 kW, 400V/3/50Hz)
- BS9KW400T (9 kW, 400V/3/50Hz)
VT: Anti-vibration mounts.

vers

(1)

H/HP
HA

VT
Accessories factory fitted only
DRE
KRB1
KRB2
KRB3
BDX

(2)

Accessories factory fitted only


DRE: Electronic soft starter device reducing
starting current by about 30%.
KRB: Electric anti-freeze heater for the base.
Prevents the formation of ice on the base.
Compatibility with the VMF system
For further system information please refer to
the specific documentation.

020

9
15A

030

9
15A

040

9
15A

045

9
15A

050

9
15A

085

9
15A

100

53

15
15

150

53

15
15

(x2)

(x2)

(1) The size ANK020H085H Inverter fans are fitted as standard


(2) Only available for 400V/3N/50Hz power supply
(x2) n the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system
requirements.

elds
1,2,3
4,5,6
7
8

9
10

11

12
13

Code
ANK
Size
020-030-040-045-050-085-090-100-150
Model
H Heat pump
Version
Standard
P With pump
A With buffer tank and pump
Execution
Standard
Coil fins
Aluminium
R Copper
S Tinned copper
V Coated aluminium (epoxy paint)
Field of use
Standard (leaving water temperature down to 4C)
Z Low temperature (Low leaving liquid from 4C down to up to 0C)
Y Low temperature (Low leaving liquid from 0C down to -8C)
Evaporator
Standatd
Power supply
M 230V/1/50Hz (from 020 to 045)
400V/3N/50Hz

209

Technical Data
Model - ANK
Cooling capacity
Total power input
EER
ESEER
Water flow rate
Total pressure drop
Available head
Heating capacity
Total power input
COP
Water flow rate
Total pressure drop
Available head
Power supply

H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA

Model - ANK
Cooling capacity
Total power input
EER
ESEER
Water flow rate
Total pressure drop
Available head
Heating capacity
Total power input
COP
Water flow rate
Total pressure drop
Available head
Power supply

H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA
H
HP/HA

kW
kW
kW
kW
W/W
W/W

l/h
kPa
kPa
kW
kW
kW
kW
W/W
W/W
l/h
kPa
kPa
V/ph/Hz

020
6,82
6,91
2,36
2,43
2,89
2,84
3,16
3,28
1173
16
65
7,98
7,87
2,54
2,59
3,14
3,04
1373
24
62
230V/1

020
6,76
6,84
2,33
2,41
2,90
2,84
3,18
3,30
l/h
1163
kPa
16
kPa
65
7,98
kW
kW
7,87
kW
2,50
kW
2,55
W/W
3,19
W/W
3,09
l/h
1373
kPa
24
kPa
62
V/ph/Hz 400V/3N
kW
kW
kW
kW
W/W
W/W

030
8,15
8,25
2,82
2,89
2,89
2,85
3,24
3,37
1402
9
70
10,05
9,91
3,11
3,15
3,23
3,15
1729
16
67
230V/1

040
9,55
9,67
3,24
3,30
2,95
2,93
3,28
3,45
1643
14
64
10,88
10,74
3,47
3,51
3,14
3,06
1871
19
62
230V/1

045
11,69
11,85
3,73
3,88
3,13
3,05
3,46
3,47
2011
14
87
13,50
13,29
3,88
3,98
3,48
3,34
2322
19
82
230V/1

050
-

085
-

100
-

150
-

030
8,15
8,25
2,82
2,89
2,89
2,85
3,24
3,35
1402
9
70
10,05
9,91
3,11
3,15
3,23
3,15
1729
15
67
400V/3N

040
10,48
10,61
3,55
3,61
2,95
2,94
3,27
3,44
1803
16
61
12,26
12,10
3,79
3,81
3,23
3,18
2109
23
57
400V/3N

045
11,57
11,74
3,98
4,12
2,91
2,85
3,25
3,26
1990
14
87
14,07
13,85
4,18
4,27
3,37
3,24
2420
21
79
400V/3N

050
13,04
13,22
4,34
4,49
3,00
2,94
3,4
3,45
2243
18
80
15,38
15,15
4,44
4,54
3,46
3,34
2645
25
72
400V/3N

085
15,48
15,68
5,22
5,35
2,97
2,93
3,33
3,41
2663
24
70
17,49
17,25
5,07
5,13
3,45
3,34
3008
30
65
400V/3N

100
25,20
25,78
8,18
8,13
3,08
3,17
3,89
4,08
4334
32
113
27,19
26,59
8,43
8,37
3,23
3,18
4677
37
113
400V/3N

150
29,20
29,92
10,13
10,20
2,88
2,93
3,85
3,93
5022
36
140
33,51
32,72
10,56
10,61
3,17
3,08
5764
47
127
400V/3N

040
13,40
13,24
3,22
3,23
4,17
4,10
400V/3N

045
14,80
14,88
3,55
3,60
4,17
4,13
400V/3N

050
16,27
16,12
3,81
3,91
4,27
4,12
400V/3N

085
18,46
18,31
4,36
4,45
4,23
4,11
400V/3N

100
29,12
28,49
7,03
6,95
4,14
4,10
400V/3N

150
35,90
35,06
8,92
8,94
4,03
3,92
400V/3N

040
11,694
11,658
2,914
2,929
4,010
3,980
230V/1

045
14,040
13,840
3,270
3,375
4,290
4,100
230V/1

050
-

085
-

100
-

150
-

Cooling: (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating: (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.

Model - ANK
Heating capacity
Total power input
COP

H
HP/HA
H
HP/HA
H
HP/HA

Power supply

020
kW
8,67
kW
8,58
kW
2,12
kW
2,18
W/W
4,10
W/W
3,94
V/ph/Hz 400V/3N

030
10,92
10,84
2,64
2,64
4,14
4,10
400V/3N

Heating: (14511:2013)
Condenser water temperature (in/out) 30C/35C; External air temperature 7C b.s./6C b.u.

Model - ANK
Heating capacity
Total power input
COP
Power supply

H
HP/HA
H
HP/HA
H
HP/HA

kW
kW
kW
kW
W/W
W/W
V/ph/Hz

020
8,363
8,256
2,039
2,124
4,100
3,880
230V/1

030
10,700
10,620
2,664
2,668
4,010
3,980
230V/1

Heating: (MCS) (14511:2008)


Condenser water temperature (in/out) 30C/35C; External air temperature 7C b.s./6C b.u.

210

Technical Data
Model - ANK

020
6,260
kW
6,048
kW
kW
1,870
kW
1,940
W/W
3,348
W/W
3,118
l/h
1470
kPa
28
kPa
55,0
V/ph/Hz 400V/3N

H
HP/HA
H
HP/HA
H
HP/HA

Heating capacity
Total power input
COP
Water flow rate
Total pressure drop
Available head
Power supply

(1)
H
HP/HA

030
8,179
8,045
2,545
2,583
3,214
3,115
1840
16
63,0
400V/3N

040
9,764
9,610
3,074
3,097
3,176
3,103
2260
24
51,0
400V/3N

045
11,239
11,021
3,378
3,467
3,327
3,179
2550
18
74
400V/3N

050
11,556
11,330
3,550
3,649
3,255
3,105
2800
22
66
400V/3N

085
13,300
12,568
4,110
4,045
3,236
3,107
3222
27
56
400V/3N

100
-

150
-

Heating: (EHPA) (14511:2008)


Condenser water temperature (in/out) 30C/35C; External air temperature 2C b.u.
(1) Water flow rates refer to conditions: Condenser water temperature (in/out) 30C/35C; External air temperature 7C b.s./6C b.u.

GENERAL DATA
Electrical data
Total input current cooling
mode
Total input current heating
mode
Maximum current (FLA)
Starting current (LRA)

(2)
(2)
(2)
(2)
(2)
(2)
(2)(3)
(2)

230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N

A
A
A
A
A
A

020

030

040

045

050

085

100

150

11,31
4,38
12,29
4,71
13,90
6,10
45,00
39,70

13,15
5,67
14,55
6,21
19,40
7,70
45,00
40,30

15,84
7,12
17,12
7,66
22,20
9,10
45,00
54,30

18,58
7,71
19,18
8,06
25,00
10,60
45,00
61,30

8,75
9,00
11,80
71,30

10,71
10,43
12,30
91,30

17,05
17,60
21,70
72,60

20,40
21,33
25,80
104,70

scroll
1
1

scroll
1
1

scroll
1
1

scroll
1
1

scroll
1
1

scroll
1
1

scroll
2
1

scroll
2
1

Compressors
type
n
n

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger
Exchanger
hydraulic connections
Fans standard

(in/out)

Fans
Air flow rate cooling mode
Sound data
Sound pressure
Sound power

0-100

0-100

0-100

0-100

0-100

0-100

0-50-100

0-50-100

type

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

type
n

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

plate
1
1"1/4

type
n
m3/h

axial
1
3500

axial
1
8000

axial
2
8000

axial
2
7500

axial
2
7500

axial
2
7500

axial
2
14500

axial
2
13500

dB(A)
dB(A)

37,0
68,0

39,5
70,5

39,5
70,5

39,5
70,5

39,5
70,5

39,5
70,5

45,5
77

46,5
78

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
(2) Unit in standard configuration/execution without hydroni kit
(3) Electronic soft start, standard for single phase versions
Nota: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions and weight

A
A

vers. H-HP

ANK
Height

(A)

Width

(B)

Depth

(C)

Weight

vers. HA

All
H/HP
HA
All
H
HP
HA

mm
mm
mm
kg
kg
kg

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

020
1028
1000
1358
400
118
123
160

030
1281
1000
1450
400
149
154
211

040
1281
1000
1450
450
152
157
214

045
1281
1000
1450
450
165
175
232

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

ANK 100 - 150


H-HP-HA

050
1281
1000
1450
450
172
182
238

085
1281
1000
1450
450
174
184
241

100
1450
1750
1750
450
296
314
364

150
1450
1750
1750
750
341
362
412

211

Cod.: SANKUY.10 / 1502

HBI
R410A

Air cooled split system heat pump for heating, cooling


and production of DHW
DC Inverter Technology
Heat capacity from 6.2kW to 16kW
HBI_C

AERMEC partecipates in the EUROVENT programme


for: LCP/A/S/R
The products of interest can be found on the website
www.eurovent-certification.com

HBI_E

HBI_WT / WTS

Unit mounted control panel (HBI_E)

Characteristics
6 sizes single phase HBI_C outdoor unit and
3 sizes three phase HBI_CT outdoor unit
available
6 sizes single phase HBI_E outdoor unit
(Hydronic module) and 3 sizes three phase
HBI_ET outdoor unit available for wall installation, with compact dimensions
4 sizes of DHW Storage Tank available of 200
300 litres capacity with main coil, electric
heater and supplementary heating coil
Refrigerant R410A
Outdoor unit with one or two fans with DC
Inverter motor for continuous speed modulation
The DC Inverter compressors have been
selected to maximise efficiency, reduce consumption and minimise starting current
Microprocessor controller
Operating modes:
-Cooling
-Heating
-Domestic Hot Water production
Possibility of prioritising operating mode
Very quiet operation
Anti-legionella Cycle: function can be set via

the Control Panel on the HBI_E indoor unit


Anti-freeze function for the Hydronic Module
and DHW Storage Tank
Indoor unit fitted (hydraulic side) with:
-water filter
-plate heat exchanger
-expansion vessel (10 litres)
-electric heaters:
1step (6 kW) for three phase unit
2 steps (1.5 kW+1.5 kW) only HBI060E unit
2 steps (3 kW+3 kW) single phase activated/
deactivated
-air vent
-safety valve (3 bar)
-flow switch
-circulation pump
-gauge
Maximum length of the refrigerant pipes up
to 30 m, maximum level difference between
outdoor unit and indoor unit 15 m
Outdoor unit supplied with Base Electric
Heating Kit to prevent the formation of ice
during heat pump operating mode
Indoor unit capable of controlling:
- 2-way valve

- 3-way valve
- Remote contact
- Ambient Thermostat
- Ambient Temperature Sensor (supplied
loose), can be installed in the wall in a rectangular 3-module recess box (type 503)
Weekly Timer
Auto-Restart Function
Operational limits:
-Cooling
Outdoor air temperature +10 C to +48 C
-Heating
Outdoor air temperature -20 C to +35 C
-Domestic Hot Water production
Outdoor air temperature -20 C to +45 C
Emergency Operation:
in the event of malfunction of the outdoor
unit operating Heating or DHW mode, the
electric heaters are activated
Condensing control device as standard; permits cooling mode operation with outdoor
temperatures down to +10 C

Accessories
HBI_WT (230V ~ 50Hz)
HBI_WTS (230V 3N ~ 50Hz)
HBI_WTT (400V 3N ~ 50Hz)
HBI_WTST (400V 3N ~ 50Hz)
200, 300 litre DHW Storage Tank with main coil and 3 kW electric sup200, 300 litre DHW Storage Tank with main coil, supplementary heatplementary heater
ing coil and 3 kW electric supplementary heater
-Magnesium sacrificial anode
-Magnesium sacrificial anode
-Stainless steel tank and coil
-Stainless steel tank and coil
-External covering in painted sheet steel and heat insulating material,
-External covering in painted sheet steel and heat insulating material,
thickness 50 mm
thickness 50 mm
-Indoor installation
-Indoor installation

212

HBI_WT/WTS Accessory Compatibility (DHW Storage Tank)


MODEL 230V~50Hz
HBI200WT/WTS
HBI300WT/WTS

HBI060

HBI080

HBI100

HBI120

HBI140

HBI160

HBI120

HBI140

HBI160

MODEL 400V 3N~50Hz


HBI200WTT/WTST
HBI300WTT/WTST

Technical Data
Cooling capacity (1) (nominal)
Input power (1) (nominal)
EER (1)
Cooling capacity (2) (nominal)
Input power (2) (nominal)
EER (2)
Heating capacity (1) (nominal)
Input power (1) (nominal)
COP (1)
Heating capacity (2) (nominal)
Input power (2) (nominal)
COP (2)
Max input power
(without electric heater) Cooling
Max input power
(without electric heater) Heating
OUTDOOR UNIT

kW
kW
kW
kW
kW
kW
kW
kW

Electric power supply


Air flow rate

HBI060C HBI080C HBI100C HBI120C HBI140C HBI160C HBI120CT HBI140CT HBI160CT


5.5
9.05
10.5
14
15
15.5
14
15
15.5
1.62
2.50
3.14
3.68
4.29
4.63
3.68
4.29
4.43
3.4
3.62
3.34
3.8
3.5
3.35
3.8
3.5
3.5
4
6.5
8.0
10
11
11.5
10
10.5
11
1.54
2.50
3.08
3.45
3.93
4.6
3.45
3.75
4.07
2.6
2.6
2.6
2.9
2.80
2.5
2.9
2.8
2.7
6.2
8.5
10
12
13.5
16
12
14
15
1.51
2.10
2.50
2.79
3.21
3.95
2.67
3.33
3.7
4.1
4.00
4.00
4.3
4.2
4.00
4.5
4.2
4.05
5.5
8.0
9.0
11.5
12.5
14
11
12
14
1.83
2.54
2.90
3.38
3.73
4.59
3.23
3.58
4.38
3
3.15
3.1
3.4
3.35
3.05
3.4
3.35
3.2

kW

2.46

6.6

6.6

7.0

7.0

7.5

kW

2.75

4.6

4.6

5.5

5.5

6.0

6.0

6.5

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz 400V 3N~50Hz 400V 3N~50Hz 400V 3N~50Hz

m/h
/
/
/
6398
6398
6398
3766
3766
3766
N of fans
n
/
1
1
2
2
2
2
2
2
R410A refrigerant charge
kg
1.7
2
2
3.3
3.3
3.3
3.5
3.5
3.5
Sound pressure
dB(A)
57
57
57
57
57
60
57
57
60
Sound pressure
dB(A)
59
59
59
59
59
62
59
59
62
Liquid 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Cooling connections
Gas 12.7(1/2) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8)
flare
Type
INDOOR UNIT
HBI060E HBI080E HBI100E HBI120E HBI140E HBI160E HBI120ET HBI140ET HBI160ET
(3)
Input power indoor unit
W
200
245
245
245
245
245
200
200
200
Pump max input power
W
200
205
205
205
205
205
200
200
200
Speeds
n
3
3
3
3
3
3
3
3
3
Electric heater capacity power (4)
kW 1.5+1.5
3+3
3+3
3+3
3+3
3+3
6
6
6
Hydraulic connections (In/Out) - (Male)

G1"
G1"
G1"
G1"
G1"
G1"
G1"
G1"
G1"
Expansion vessel capacity
l
10
Electric power supply
Outlet water temperature
Outlet water temperature
Outlet water temperature
Outlet water temperature
Sound pressure

230V~50Hz

(range)
(range)
(1) (range)
(2) (range)
(1)
(2)

Cooling connections

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz 400V 3N~50Hz 400V 3N~50Hz 400V 3N~50Hz

C
18 25
C
7 25
C
25 45
C
25 55
dB(A)
31
Liquid 6.35(1/4) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8)
Gas 12.7(1/2) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8)
flare
Type

HBI_WT/WTS Accessory Technical Data


Domestic Hot Water storage tank
Capacity
DHW outlet temperature

l
C
kW
A

Electric heater capacity


Electric heater input current
Electric power supply
Utility hydraulic connections (In/Out) - (Female)
Main coil hydraulic connections (In/Out) - (Female)
Supplementary coil hydraulic connections (In/Out) - (Female)
Supplementary coil

L
xs

m
mm

HBI200WT/WTT HBI200WTS/WTST HBI300WT/WTT


200
200
300
40 80 (5)
3
3
3
13
13
13

HBI300WTS/WTST
300
3
13

230V~50Hz
400V 3N~50Hz

230V~50Hz
400V 3N~50Hz

230V~50Hz
400V 3N~50Hz

230V~50Hz
400V 3N~50Hz

G1/2
G3/4
-

G1/2
G3/4
G3/4
10
22 x 0,8

G1/2
G3/4
-

G1/2
G3/4
G3/4
10
22 x 0,8

Data in accordance with UNI EN 14511-2013

DHW outlet temperature


(3)

Pump max power input + Auxiliaries


Electric heater 2 step ON/OFF control from Control Pane
(5) With electric heater/without electric heaters 40 y50C
(4)

(1) Under

(2) Fan

floor system

Cooling
- Inlet/outlet water temperature
- External air temperature
(1) Under

coil units

Cooling
23C / 18C
35C B.S. / 24CB.U.

- Inlet/outlet water temperature


- External air temperature
(2) Fan

floor system

coil units

Heating (without electric heaters):

Heating (without electric heaters):

- Inlet/outlet water temperature


- External air temperature

- Inlet/outlet water temperature


- External air temperature

30C / 35C
7C B.S. / 6C B.U.

12C / 7C
35C B.S. / 24C B.U.

40C / 45C
7C B.S. / 6C B.U.

Sound pressure measured at 1m in a semi anechoic chamber


Sound pressure measured at 1.4m in a semi-anechoic chamber

213

HBI System Configuration

OUTDOOR UNIT

INDOOR UNIT

Under floor system

2-way valve

3-way valve

Supplementary heat sources

Fan coils

Storage tank
HBI_WT / WTS

The supplementary coil is


present only in HBI_WTS
models

Supply
The main coil is
present in all HBI_WT
/ WTS modelS

Fan coils

Water inlet

Fill point

System example - operating in heating mode

214

Tank drain

Dimensional Data

C
A

A
B
C
Indoor unit
MODEL
HBI060E
HBI080E
HBI100E
HBI120E
HBI140E
HBI160E
HBI120ET
HBI140ET
HBI160ET

Outdoor Unit
Height(A)
(mm)
900
900
900
900
900
900
900
900
900

Width(B)
(mm)
500
500
500
500
500
500
500
500
500

Depth(C)
(mm)
324
324
324
324
324
324
324
324
324

Net weight Gross weight


(kg)
(kg)
52
62
52
62
52
62
53
63
53
63
53
63
53
63
53
63
53
63

MODEL
HBI060C
HBI080C
HBI100C

Height (A)
(mm)
791
791
791

Width (B)
(mm)
921
921
921

Depth (C)
(mm)
427
427
427

Net weight Gross weight


(kg)
(kg)
66
71
69
74
69
74

A
A

B
C
Storage Tank

Height (A)
(mm)
HBI120C
1253
HBI140C
1253
HBI160C
1253
HBI120CT
1253
HBI140CT
1253
HBI160CT
1253
MODEL

Width (B)
(mm)
950
950
950
950
950
950

Depth (C)
(mm)
412
412
412
412
412
412

Net weight Gross weight


(kg)
(kg)
99
108
99
108
99
108
99
108
99
108
99
108

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

MODEL
HBI200WT / WTS
HBI300WT / WTS

Height (A)
(mm)
1595
1620

Width (B)
(mm)
540
620

Net weight* Gross weight


(kg)
(kg)
68 / 71
77 / 80
82 / 87
92 / 97

Cod.: SHBIUY.01 / 1201

Outdoor unit

* Weight when empty

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

215

SWP

High temperature air cooled heat pumps for the production of domestic
hot water

AIR COOLED HEAT PUMPS FOR HOT WATER PRODUCTION UP TO 60C (UP TO 70C WITH
AUXILIARY ELECTRIC HEATER)
APPLICATION RANGE: IN HEAT PUMP WITH AIR INTAKE FROM 8C TO 35C (EXTENDED
FROM -15C TO 45C WITH THE AID OF THE AUXILIARY ELECTRIC HEATER)
VERSIONS WITH 300 LITRES STORAGE TANK, OR WITH 1 OR 2 COILS TO BE USED
TOGETHER WITH OTHER HEAT SOURCES (SOLAR PANELS, BOILER, HEAT PUMP)
AUTOSTART FUNCTION FOR THE UNIT TO RESTART AUTOMATICALLY
Features
The SWP heat pumps use the thermal energy of
air for production of domestic hot water. The
process occurs in the most efficient and profitable way with average COPs > 3. The energy
advantage of the SWP heat pumps also safeguards the environment, using most of its energy from solar radiation. Easy installation, silent
and reliable functioning and very low maintenance requirements complete the benefits of
this highly ecological and economic system.
Main features
Steel tank with a double vitrification layer
with storage capacity of 300 litres, (SWP 300,
SWP 300 S1 and SWP 300 S2)
Condenser wrapped externally to the boiler
with no scales and refrigerant-water fluid
contamination
Auxiliary coil to be used together with a boiler or solar panels
Integrated NTC sensor to control the water
temperature
External air sensor for automatic connection
of the electric heater with unfavourable temperatures in heat pump mode
Anti-corrosion magnesium anode

216

Hydraulic connections located at rear of unit


Thermal insulation made of very thick
expanded polyurethane foam with a silver
grey RAL 2006 external covering (ABS)
Adjustable support feet
Environmentally friendly refrigerant R134a
Electric heater 1.5 kW 230V
IEC power supply connector with insulating
sheath
High pressure safety devices
Reciprocating hermetic compressor
Radial fan with an adjustment of 40 % of the
nominal flow rate
Electronic controller:
- water set point adjustment
- external air temperature sensing
- auto-diagnostic with display of the high/low
pressure alarm, water overheating alarm and
disconnected sensors alarm
- record of run hours
- control of minimum time between successive
compressor starts
- setting of parameters from the keyboard
- control of electric heater in manual mode or
in supplementary automatic mode for low
external temperatures

- periodic antibacterial treatment cycle to eliminate and prevent Legionella from developing
- user display to set the operating mode and
various parameters with different levels of
accessibility by means of passwords
Possible configurations
Standard where the heat pump and the electric heater are the source of heat ( SWP 300)
With auxiliary coil to be used together with a
boiler or solar panels (SWP 300 S1)
With double auxiliary coils for simultaneous
use of three heat sources (SWP 300 S2)

Dimensional Data (mm)


SWP 300

SWP 300 S2

SWP 300 S1

Technical Data
Mod.
Voltage - phases - frequency
Heating capacity in heat pump mode
Electric heater power
Maximum water temperature
Intake air operating range
Total input power
Max total input current in heat pump mode
Max total input current in electric heater mode
Compressor
Fan
Air flow rate
Min sound power
Max sound power
Max ducted length
Air ducts minimum diameter
Working pressure
Sound pressure level
DHW hot water flow connection
DHW cold water return connection
Heating system return connection
Heating system flow connection
Recirculation connection
Alternative heat source 1 and 2 return connection
Net weight
Gross weight
Storage tank capacity
Unit dimensions

Packaging dimensions

V-Ph-Hz
W
W
C
C
W
A
A
Type / number
Type / number
m3/h
dB(A)
dB(A)
m
mm
bar
dB(A)

Kg
Kg

SWP 300
230 - 1 - 50
2.150
1500
60
+8*/+35
640
3,9
6,8

450
59
71
10
160
6
52
1
1
1
1
1/2
1
116
137

L
Height
Width
Depth
Height
Width
Depth

SWP 300 S1
230 - 1 - 50
2.150
1500
60
+8*/+35
640
3,9
6,8
reciprocating/1
centrifugal/1
450
59
71
10
160
6
52
1
1
1
1
1/2
1
94
115
300
1.865
660
660
2.050
770
770

SWP 300 S2
230 - 1 - 50
2.150
1500
60
+8*/+35
640
3,9
6,8

450
59
71
10
160
6
52
1
1
1
1
1/2
1
134
155

* default settings
Sound pressure measured in free field at a distance of 10m from the front and directivity factor = 2. In accordance with ISO 3744.
Performances in accordance with EN 255-3
Heating:
Condenser
Inlet temperature
15 C
Outlet temperature
50 C
External air temperature
15 C

Cod.: SSWPUY.02 / 1503

Installation Examples

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

217

NRL
0280/0750

Air/Water Chillers for external installation


Scroll compressors, plate heat exchangers and axial fans
Cooling capacity 53194kW

cooling only

R410A
AERMEC
partecipates in the EUROVENT
programme for: LCP Check ongoing
validity of certificate online:
www.eurovent-certification.com

COMPACT VERSION
HIGH EFFICIENCIES ALSO AT PARTIAL LOADS
EASY AND FAST INSTALLATION
Characteristics
Chillers for external installation for chilled water production with high performance scroll compressors
and low electric absorption , axial fans, external
copper coils with aluminum fins , plate heat exchangers.
In the units (with desuperheater or total recovery) it
is also possible to produce free-hot water. The basement, the structure and the panelling are in steel treated with polyester anti-corrosion paints .
Versions
NRL_
NRL_L
NRL_A
NRL_E

standard
Low noise
High efficiency
Low noise high efficiency

Operating range: Work at full load up to 46C


external air temperature (for more details please

refer to the technical documentation)


Units with two refrigerant circuits designed to
grant the maximum performance at full load,
ensuring high efficiencies also at partial loads and
giving continuity in case of stop of one of the two
circuit.
Standard Flow-switch, water filter and high
and low pressure transducer.
Possibility of integrated hydronik -kit, which
includes the main hydraulic components; it is
available in different configurations with or
without buffer tank, one or two high and low
head pumps.
Microprocessor adjustment, with keyboard and
LCD display, for easy consultation and intervention on the unit via a menu available in several
languages.
Adjustment includes complete management of

the alarms and their log.


- The presence of a programmable timer allows setting time bands of operation and a possible
second set-point
- The temperature control takes place with the integral proportional logic, based on the water output
temperature.
- Night Mode: it is possible to set a silenced operation profile.
Perfect for night operation, since it guarantees greater acoustic comfort in the evenings, and a high
efficiency in the time of greater load.

work;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor
and remote control max. 18 units in RS485
network with integrated GPRS modem
DCPX: Device for condensation temperature control, with continuous speed modulation of fans by using a pressure transducer.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
VT: anti-vibration support, to be fitted below

the sheet metal base of the unit.


Accessories factory fitted only
DRE: Current soft starter device, Available
only with power supply 400V/3N.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current
PRM1: It is a manual pressure switch electrically wired in series with the existing
automatic high pressure switch on the
compressor discharge pipe

Night Mode is standard on all low noise versions.


For all other versions either the DCPX accessory
or J inverter fan must be specified to allow
Night Mode to operate.

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
PGD1: Simplified remote panel. Allows control of basic unit functions and alarm notification.
MULTICHILLER_PCO: Control system to
switch the individual chillers on and off, and
command them, in a system in which several units are installed in parallel, always
ensuring a constant delivery to the evaporators.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 net-

218

Compatibility of accessories
Mod. NRL
AER485P1
PGD1
TP3
MULTICHILLER_PCO
AERWEB300
DCPX standard fan

DCPX
increased fans (M)
GP

Vers.

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)

VT (00-P1-P4)
VT (01-10)
Accessories factory fitted only
DRE
RIF
PRM1

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

All
All
All

L
A
E

L
A
E
-L
A-E
-L
A-E
-L
A-E

standard

standard

standard

standard

standard

standard

standard

standard

standard

standard

63
63
3
3
17
17
13
13

63
63
3
4
17
17
13
13

63
63
3
4
17
17
13
13

63
63
3
4
17
17
13
13

64
standard
64
standard
64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
64
standard
65
standard
2 (x2)
2 (x3)
13
22
10
22

400V/3N
Alls
Alls

281
50

301
50

331
50

351
51

501
52

551
52

601
53

651
53

701
53

inverter fan
-

inverter fan

64
standard
64
standard
65
standard
65
standard
10 (x3)
10 (x3)
23
23
23
23

751
53

(1) Standard in the models with desuperheater; In versions low noise; Not necessary fields with fans inverter
(2) (x2)(x3) the number in brackets indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7
8

Y
X
9

C
10

D
T
11

L
A
E
12

R
S
V
13

M
J
14

Code
NRL
Size
0280-0300-0330-0350-0500-0550-0600-0650-0700-0750 (3)
Expansion valve
Standard (leaving water temperature down to 4C)
Low temperature (Low leaving liquid from 0C down to -6C) (4)
Electronic expansion valve (leaving water temperature down
to 4C) contact head office for lower temperatures
Model
Chillers
Condensing unit (5)
Heat recovery
Without recovery
With Desuperheater
With Total Recovery
Versione
Compact
Compact low noise
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans (6)
Standard
Increased
Inverter
Power supply
400V/3N/50Hz with circuit breakers
220V/3/50Hz with circuit breakers

15-16
00
01
02
03
04
05
06
07
08
09
10
P1
P2
P3
P4

Hydronic kit (7)


Without hydronic kit
n1 low head pump and buffer tank
n2 low head pump and buffer tank
n1 high head pump and buffer tank
n2 high head pump and buffer tank
n1 low head pump and buffer tank (with holes for immersion heaters)
n2 low head pump and buffer tank (with holes for immersion heaters)
n1 high head pump and buffer tank (with holes for immersion heaters)
n2 high head pump and buffer tank (with holes for immersion heaters)
double hydraulic circuit
double hydraulic circuit with holes for immersion heater
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump

(3) The sizes 0280-0300-0330-0350 are only low noise L/E with inverter fans
(4) Temperature limit of produced water: -6C version "/L -8 version "A/E"; The option Y is not compatible with the motocondensing units C; with the option D and T
(5) The motocondensing models are not configurable with the option D and T, and with the integrated hydronik-kit on the system's side.
(6) On / off fan Standard, standard sizes up 0500 to 0750
On / off fan Increased, option available for all sizes
Fans Inverter, standard sizes from 0280 to 0350, with no static pressure
Fans Inverter, option for sizes from 0500 to 0750 with static pressure
(7) Buffer tanks with holes for additional heaters are supplied from factory with plastics caps of protection, before system's loading, where the installation of one or all the
heaters is not provided, it is mandatory to replace plastic caps with special caps, which are commonly available in the market.

219

Technical Data
Chillers

L
A
E

L
A
E

L
A
E

L
A
E

L
A
E

L
A
E

Cooling capacity

Total power input

EER

ESEER

Water flow rate

Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa

0280
52,6
56,6
20,7
17,1
2,54
3,30
3,01
3,75
9120
9800
51
43

0300
62,6
64,6
23,01
19,7
2,72
3,27
3,22
3,72
10840
11180
46
39

0330
67,5
73,6
26,5
22,1
2,54
3,32
3,01
3,80
11700
12730
54
35

0350
80,4
82,5
28,9
25,5
2,78
3,23
3,29
3,68
13930
14280
55
44

0500
96,4
86,5
97,4
89,5
35,4
38,9
30,7
33,5
2,72
2,22
3,17
2,67
3,28
3,27
3,68
3,65
16680
14960
16860
15480
53
43
44
37

0550
102
92,4
103
94,5
38,9
43,0
34,8
37,2
2,63
2,15
2,97
2,54
3,17
3,17
3,45
3,43
17720
16000
17890
16340
59
48
49
41

0600
125
112
128
116
46,7
51,5
40,8
44,9
2,68
2,18
3,14
2,59
3,66
3,66
4,07
3,97
21670
19440
22190
20120
64
51
54
44

0650
136
126
142
128
54,7
58,2
45,4
52,3
2,49
2,17
3,13
2,45
3,42
3,42
4,04
3,95
23560
21840
24600
22190
61
52
60
49

0700
155
143
162
149
61,0
65,6
53,2
57,3
2,54
2,18
3,04
2,60
3,48
3,48
3,93
3,83
26830
24770
28040
25800
74
63
68
58

0750
189
173
194
179
70,6
76,1
63,2
69,0
2,67
2,27
3,06
2,59
3,63
3,65
3,91
3,82
32680
29928
33540
30960
86
72
88
75

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C

0280

Condensing unit

C1

L
A
E

L
A
E

L
A
E

Cooling capacity

Total power input

EER
Connections
Gas line
liquid line

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W

C2
-

0300
C1

C2
-

0330
C1

C2

0350
C1

C2

0500
C1

0550

C2

C1

C2

0600
C1

C2

0650
C1

C2

0700
C1

C1 C2

57,0/43,0 65,0/41,0 65,0/65,0 70,5/70,5 80,5/80,5

26,33
22,00
2,66
3,47

28,66
25,33
2,91
3,38

35,11
38,85
30,47
33,40
2,85
2,31
3,31
2,78

38,54
42,88
34,51
37,03
2,75
2,23
3,10
2,64

46,31
51,36
40,46
44,70
2,80
2,27
3,28
2,70

54,39
58,12
45,00
52,06
2,59
2,25
3,27
2,55

60,54
65,38
52,77
57,11
2,65
2,27
3,18
2,71

196
179
201
185
70
76
62
69
2,80
2,37
3,22
2,70

27,5/27,5 37,0/28,0 35,0/35,0 41,5/41,5 51,0/39,0 58,0/38,0 58,0/58,0 65,5/65,5 74,0/74,0


-

57,5/43,5 65,5/41,5 66,5/66,5 73,5/73,5 84,0/84,0

29,5/29,5 38,0/29,0 38,0/38,0 42,5/42,5 53,0/40,0 60,0/38,0 60,5/60,5 66,5/66,5 77,5/77,5


20,48
16,95
2,67
3,46

22,80
19,57
2,85
3,42

0750

C2

28/28

28/28

28/28

15,88/15,88

15,88/15,88

15,88/15,88

28/28
18/18

35/28
18/18

35/28
18/18

35/35
22/22

35/35
22/22

42/42
28/28

42/42
28/28

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

A
A
A
A
A
A

36
30
46
155

40
34
53
184

44
37
58
190

51
45
63
200

63
70
55
60
76
214

67
75
60
64
81
220

81
90
71
78
100
232

88
99
77
89
112
243

100
111
90
97
122
261

122
113
113
109
144
320

type
n
n
type

2
2

2
2

2
2

2
2

3
2

3
2

4
2

4
2

4
2

4
2

1
2"

1
2"

1
2"

1
2"

1
3"

Cooling:
Evaporating temperature 5C; External air temperature 35C

Electrical data

Total input current

(1)
(1)
(1)
(1)

L
A
E

Maximum current (FLA)


Starting current (LRA)
Compressors
Compressors
Circuits
Refrigerant
System side exchanger
Exchanger
hydraulic connections

(1) (in/out)

type
n

(1) Data of the versions without hydronic module integrated

220

scroll

R410A
plate
1
2"

1
2"

1
2"

1
2"

1
2"

Technical Data
0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

4
6
14200
22000

4
6
14200
22000

4
8
14200
27000

6
8
20200
27000

axial
2
2
2
2
2
2
2
2
34600
34600
28400
28700
34100
34100
21100
22200

2
2
2
2
34600
27700
32600
21800

2
2
2
2
34600
29400
32600
22800

2
2
3
3
33600
28600
50000
32500

3
3
3
3
51400
42700
49000
35300

l
kPa

300

300

300

300

500

500

500

700

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

73
74
41
42

83
78
85
77
51
46
53
45

85
80
85
77
53
48
53
45

Fans standard

L
A
E

L
A
E

fans

Air flow rate cooling mode

type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

Hydronic kit
Buffer tank
Useful static pressure
Sound data

L
A
E

L
A
E

Sound power

Sound pressure

Power supply

500

500

For more information, refer to the technical documentation


73
74
41
42

74
75
42
43

75
76
43
44

82
77
82
74
50
45
50
42

82
77
82
74
50
45
50
42

82
77
82
74
50
45
50
42

83
78
83
75
51
46
51
43

400V/3N/50Hz

Sound power (cooling operation)


Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure (cooling operation)
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
NRL 0280-0300-0330 L

NRL 0350 L

NRL 0500-0550-0600-0650-0700 /L

A
A

C
B

NRL 0280-0300 E

NRL 0330-0350 E

NRL 0500-0550-0600-0650 A/E

NRL 0700 A/E - 0750 /L/A/E

A
A

C
B

Mod. NRL
Height
Width

(mm)
(mm)

A
B

Length

(mm)

Weight
empty

(kg)

C
B

Vers.
All
All
/L/C
A/E/C
/L
A/E

0280
1606
1100
2450
2450
675
686

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

0300
1606
1100
2450
2950
684
751

0330
1606
1100
2450
2950
688
761

0350
1606
1100
2450
2950
704
767

0500
1875
1100
3010
3010
868
955

0550
1875
1100
3010
3010
872
959

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

0600
1875
1100
3010
3010
968
1142

0650
1875
1100
3010
3010
983
1155

0700
1875
1100
3010
4010
1091
1323

0750
1975
1500
4350
4350
1382
1663

221

Cod.: SNRLUY.14 /1502

NRL
0280/0750

Air/Water Reversible heat pumps for external installation


Scroll compressors, plate heat exchangers and axial fans
Cooling capacity 51179kW
Heating capacity 58205kW

heat pumps

R410A
AERMEC
partecipates in the EUROVENT
programme for: LCP Check ongoing
validity of certificate online:
www.eurovent-certification.com

EUROVENT EFFICIENCY'S CLASS"A" IN HEATING


OPERATION
HIGH EFFICIENCIES ALSO AT PARTIAL LOADS
FAST AND EASY INSTALLATION
Characteristics
Reversible heat pumps for external installation for
the production of chilled/ heated water with high
performance and low electric absorbtion scroll
compressors , axial fans, external copper coils with
aluminium fins, system-side plate heat exchanger.
In the units with desuperheater, but in cooling-only
operation, it is possible to produce free hot water.
The basement, the structure and the panelling are in
steel treated with polyester anti-corrosion paint.
Version
NRL_H
NRL_HL
NRL_HA
NRL_HE

Standard heat pumps


Standard heat pumps Low noise version
High efficiency version
High efficiency version Low noise version

Operating limits: Work at full load down to -15C external air temperature in winter season, up to 46C in
summer season. Hot water production up to 55C

(for more details please refer to the technical documentation)


Units with two refrigerant circuits designed to
reach the maximum performance at full load,
granting high efficiencies also at partial loads and
assuring continuity in case of stop of one of the
two circuits.
Flow switch, water filter and high and low
pressure transducer are standard supplied.
Possibility of integrated hydronic kit which includes the main hydraulic components; it is available
in different configurations with or without buffer
tank, one or two pumps high and low head.
Microprocessor adjustment, with keyboard and
LCD display, for easy consultation and intervention on the unit via a menu available in several
languages.
Adjustment includes complete management of
the alarms and their log.

- The presence of a programmable timer allows setting time bands of operation and a possible
second set-point
- The temperature control takes place with the integral proportional logic, based on the water output
temperature.
- Night Mode: it is possible to set a silenced operation profile.
Perfect for night operation, since it guarantees greater acoustic comfort in the evenings, and a high
efficiency in the time of greater load.

AERWEB300-18: Web server to monitor and


remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor
and remote control max. 18 units in RS485
network with integrated GPRS modem
DCPX: Device for condensation temperature control, with continuous speed modulation of fans by using a pressure transducer.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
VT: anti-vibration support, to be fitted below
the sheet metal base of the unit.

Accessories factory fitted only


DRE: Current soft starter device, Available
only with power supply 400V/3N.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current
PRM1: It is a manual pressure switch electrically wired in series with the existing
automatic high pressure switch on the
compressor discharge pipe.

Night Mode is standard on all low noise versions.


For all other versions either the DCPX accessory
or J inverter fan must be specified to allow
Night Mode to operate.

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
PGD1: Simplified remote panel. Allows control of basic unit functions and alarm notification.
MULTICHILLER_PCO: Control system to
switch the individual chillers on and off, and
command them, in a system in which several units are installed in parallel, always
ensuring a constant delivery to the evaporators.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;

222

COMPATIBILITY with the VMF SYSTEM For


more information on the system refer to the
manual.

Compatibility of accessories
Mod. NRL
AER485P1
PGD1
MULTICHILLER_PCO
AERWEB300
DCPX

DCPX
Increased fans (M)
GP

Vers.
all
all

0280

all
H
HL
HA
HE
H
HL
HA
HE
H-HL
HA-HE
H-HL
HA-HE
H-HL
HA-HE

400V/3N
all
all

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)

VT (00-P1-P2-P3-P4)
VT (01...10)
Accessories factory fitted only
DRE
RIF
PRM1

0300

0330

63
63
3
3
17
17
13
13

inverter fans
inverter fans
63
63
63
63
3
3
4
4
17
17
17
17
13
13
13
13

281
50

301
50

331
50

0350

0500

0550

0600

0650

0700

0750

64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

64
standard
65
standard
2 (x2)
2 (x3)
13
22
10
22

63
63
3
4
17
17
13
13

64
standard
64
standard
2 (x2)
2 (x2)
13
13
10
10

351
51

501
52

551
52

601
53

651
53

701
53

64
standard

65
standard

10 (x3)
10 (x3)

23
23
23
23

751

53

(1) Standard in the models with desuperheater; In the low noise versions; Not necessary fields with ventilarori inverter
(2) (x2)(x3) the number in brackets indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Field
1,2,3
4,5,6,7
8

X
9
H
10

D
11

L
A
E
12

R
S
V
13

M
J

Code
NRL
Size
0280-0300-0330-0350-0500-0550-0600-0650-0700-750 (3)
Expansion valve
Standard (leaving water temperature down to 4C)
Electronic expansion valve (leaving water temperature down
to 4C) contact head office for lower temperatures (4)
Model
Heat pumps
Heat recovery
Without recovery
With Desuperheater (5)
Version
Compact
Compact low noise
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans (6)
Standard
Increased
Inverter

14

Power supply
400V/3N/50Hz with circuit breakers
1 220V/3/50Hz with circuit breakers
15-16
Hydronic kit (7)
00 Without hydronic kit
01 n1 low head pump and buffer tank
02 n2 low head pump and buffer tank
03 n1 high head pump and buffer tank
04 n2 high head pump and buffer tank
05 n1 low head pump and buffer tank (with holes for immersion heaters)
06 n2 low head pump and buffer tank (with holes for immersion heaters)
07 n1 low high pump and buffer tank (with holes for immersion heaters)
08 n2 low high pump and buffer tank (with holes for immersion heaters)
09 double hydraulic circuit
10 double hydraulic circuit with holes for immersion heaters
P1 n1 low head pump
P2 n2 low head pump
P3 n1 high head pump
P4 n2 high head pump

(3) The size 0280-0300-0330-0350 only available in low noise version "HL/HE" with inverter fans
(4) Options D are not compatible with option X
(5) The desuperheater can be used exclusively in the cold operation
(6) On / off fan Standard, standard sizes up 0500 to 0750
On / off fan Increased, option for size up 0280 tu 0350
Fans Inverter, standard sizes from 0280 to 0350, with no static pressure
Fans Inverter, option for sizes from 0500 to 0750 with static pressure
(7) Buffer tanks with holes for additional heaters are supplied from factory with plastics caps of protection, before system's loading, where the installation of one or all the
heaters is not provided, it is mandatory to replace plastic caps with special caps, which are commonly available in the market.

223

Technical Data
Mod. NRL Heat pumps
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE

Cooling capacity

Total power input

EER

ESEER

Water flow rate

Total pressure drop

Heating capacity
Total power input
COP
Water flow rate
Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W

l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

0280
50.6
53
20.4
18.10
2.48
2.92
3.02
3.85
8772
9116
47
20
58.4
59
19.0
17.55
3.07
3.38
9976
10148
61
25

0300
60.6
61.7
22.8
20.3
2.65
3.04
3.23
3.77
10492
10664
43
27
68.4
69.3
21.7
20.6
3.15
3.36
11696
11868
54
34

0330
65.5
68.7
26.6
23.3
2.46
2.95
3.02
3.85
11352
11868
51
23
75.5
76.2
24.8
22.8
3.04
3.34
12900
13072
66
28

0350
72.5
76.6
31.2
26.9
2.32
2.85
3.31
3.73
12556
13244
45
29
82.5
86.4
28.3
26.1
2.91
3.30
14104
14792
56
36

0500
89.4
82.5
93.5
89.6
36.9
40.0
30.7
33.4
2.42
2.06
3.04
2.68
3.30
3.28
3.71
3.67
15480
14276
16168
15480
46
39
33
30
99.6
103.5
33.7
31.7
2.95
3.26
17028
17716
55
40

0550
94.4
89.5
99.5
94.5
41.0
43.4
34.0
36.8
2.30
2.06
2.92
2.57
3.19
3.18
3.48
3.45
16340
15480
17200
16340
50
45
36
32
107
110.5
36.7
34.4
2.90
3.21
18232
18920
62
44

0600
114.3
109.3
121.4
113.5
49.7
52.3
41.6
45.4
2.3
2.09
2.92
2.5
3.69
3.66
4.13
4.03
19780
18920
20984
19608
53
49
36
31
129.8
135.6
44.0
40.7
2.95
3.33
22188
23220
67
44

0650
133.2
123.3
137.3
127.4
54.1
59.0
48.5
53.3
2.46
2.09
2.83
2.39
3.42
3.42
4.09
3.99
23048
21328
23736
22016
58
50
43
37
150.9
152.7
49.02
45.75
3.08
3.34
25800
26144
73
52

0700
144.1
139.1
149.2
142.3
63.7
66.2
52.1
58.5
2.26
2.10
2.86
2.43
3.50
3.48
3.98
3.87
24940
24080
25800
24596
64
60
49
45
166.1
171.9
56.3
53.0
2.95
3.24
28380
29412
83
64

0750
174.8
164.0
178.9
174.0
71.0
78.4
64.1
69.9
2.46
2.09
2.79
2.49
3.66
3.67
3.98
3.87
30272
28380
30960
30100
74.0
65.0
64.0
60.0
202.3
205.3
66.5
62.6
3.04
3.28
34572
35088
82
82

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

A
A
A
A
A
A
A
A
A
A

36
30
33
35
46
155

40
34
38
39
53
184

44
37
41
43
58
190

51
45
50
49
63
200

63
70
55
60
60

67
75
60
64
63

81
90
71
78
76

88
99
77
89
82

100
111
90
97
95

55
60
76
214

59
64
81
220

72
79
100
232

82
91
112
243

88
99
122
261

122
132
113
120
113
113
113
113
144
320

type
n
n
type

2
2

2
2

2
2

2
2

3
2

3
2

4
2

4
2

4
2

4
2

1
2"

1
2"

1
2"

1
2"

1
3"

2
2
2
2
39400
28700
36500
21400
39400
36500

2
2
2
2
37500
27400
36500
22400
37500
36500

2
2
3
3
37500
28100
58000
31900
37500
58000

3
3
3
3
50200
41700
48000
34600
50200
48000

Electrical data
Total input current
cooling mode
Total input current
heating mode

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

H
HL
HA
HE
H
HL
HA
HE

Maximum current (FLA)


Starting current (LRA)
Compressors
Compressors
Circuits
Refrigerant
System side exchanger

Fans

Air flow rate cooling mode


Air flow rate heating mode

(1)

(in/out)

1
2"

1
2"

1
2"

1
2"

H
HL
HA
HE
H
HL
HA
HE
H/HL
HA/HE

type
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

4
6
14000
20000
14000
20000

6
8
20000
26000
20000
26000

6
8
20000
26000
20000
26000

6
8
20000
26000
20000
26000

(1) Data of the versions without hydronic module integrated

224

R410A

type
n

Exchanger
hydraulic connections
Fans standard

scroll

plate
1
2"

axial
2
2
2
2
2
2
2
2
39400 39400
28400 28700
37000 37000
20200 21100
39400 39400
37000 37000

Technical Data
Hydronic kit
Buffer tank
Useful static pressure
Sound data

l
kPa
H
HL
HA
HE
H
HL
HA
HE

Sound pressure

Sound power
Power supply

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

0280

0300

300

300

41
42
73
74

42
43
74
75

0330

0350

0500

0550

0600

0650

300
300
500
500
500
500
For more information, refer to the technical documentation
42
43
74
75

43
44
75
76

50
50
45
45
50
50
42
42
82
82
77
77
82
82
74
74
400V/3N/50Hz

50
45
50
42
82
77
82
74

0700

0750

500

700

51
46
53
45
83
78
85
77

53
48
53
45
85
80
85
77

51
46
51
43
83
78
83
75

Sound power (cooling mode)


Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure (cooling mode)
Sound pressure in free field, at 10m. distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
NRL 0280 HL

NRL 0300-0330-0350 HL

NRL 0500-0550-0600-0650-0700 H/HL

A
A

C
B

NRL 0280 HE

NRL 0300-0330-0350 HE

NRL 0500-0550-0600-0650 HA/HE

NRL 0700 HA/HE


NRL 0750 H/HL/HA/HE

A
A

C
B

Mod. NRL
Height
Width

(mm)
(mm)

A
B

Length

(mm)

kg

(1)

Vers.
Alls
Alls
H/HL
HA/HE
H/HL
HA/HE

0280
1606
1100
2450
2450
713
730

0300
1606
1100
2450
2950
724
795

0330
1606
1100
2450
2950
731
805

0350
1606
1100
2450
2950
740
811

0500
1875
1100
3010
3010
913
1099

0550
1875
1100
3010
3010
917
1103

0600
1875
1100
3010
3010
1016
1204

0650
1875
1100
3010
3010
1130
1212

0700
1875
1100
3010
4010
1142
1390

0750
1975
1500
4350
4350
1487
1748

Cod.: SNRLHUY.13 / 1502

Weight empty

C
B

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

225

NRL
0800/1800

Air/Water Reversible heat pumps for external installation


Scroll compressors, plate heat exchangers and axial fans
Cooling capacity 183 470kW
Heating capacity 228 526kW

heat pump

R410A
Aermec adheres to the EUROVENT
Certification programme up to 600kW
cooling. The products concerned appear
in the EUROVENT Certified products
guide.

EUROVENT EFFICIENCY'S CLASS"A" IN HEATING


OPERATION*
HIGH EFFICIENCIES ALSO AT PARTIAL LOADS
FAST AND EASY INSTALLATION
* HA version, except for sizes 1250 and1504

Characteristics
duction up to 55C (for more details please
refer to the technical documentation)
Units with two refrigerant circuits designed
to reach the maximum performance at full
load, granting high efficiencies also at partial
loads and assuring continuity in case of stop
of one of the two circuits.
Water filter and high and low pressure transducers are standard supplied, The flow
switch is standard in all the configurations for
compact versions (0800-1200 H/HL), for the
other sizes and configurations it is provided
only with the hydronic-kit.
Possibility of integrated hydronic kit which
includes the main hydraulic components; it is
available in different configurations with or
without buffer tank, one or two pumps high
and low head.
Microprocessor adjustment, with keyboard and
LCD display, for easy consultation and intervention on the unit via a menu available in several

languages.
Adjustment includes complete management of
the alarms and their log.
- The presence of a programmable timer allows setting time bands of operation and a possible second set-point
- The temperature control takes place with the integral proportional logic, based on the water output
temperature.
- Night Mode: it is possible to set a silenced operation profile.
Perfect for night operation, since it guarantees
greater acoustic comfort in the evenings, and a
high efficiency in the time of greater load.

AER485P1: RS-485 interface for supervising


AERWEB300-18: Web server to monitor and
systems with MODBUS protocol.
remote control max. 18 units in RS485 net PGD1: Simplified remote panel. Allows conwork;
trol of basic unit functions and alarm notificaAERWEB300-6G: Web server to monitor and
tion.
remote control max. 6 units in RS485 net MULTICHILLER_PCO: Control system to
work with integrated GPRS modem;
switch the individual chillers on and off, and
AERWEB300-18G: Web server to monitor
command them, in a system in which several
and remote control max. 18 units in RS485
units are installed in parallel, always ensuring
network with integrated GPRS modem
a constant delivery to the evaporators.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a com DCPX: Device for condensation temperature
mon PC and an ethernet connection over a
control, with continuous speed modulation of
common browser; 4 versions available:
fans by using a pressure transducer.
AERWEB300-6: Web server to monitor and
AVX: anti-vibration support, to be fitted
remote control max. 6 units in RS485 netbelow the sheet metal base of the unit.
work;

Accessories factory fitted only


DRE: Current soft starter device, Available
only with power supply 400V/3N.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current
PRM1: It is a manual pressure switch
electrically wired in series with the existing
automatic high pressure switch on the compressor discharge pipe.

Reversible heat pumps for external installation


for the production of chilled/ heated water with
high performance and low electric absorbtion
scroll compressors , axial fans, external copper
coils with aluminium fins, system-side plate
heat exchanger.
In the units with desuperheater, but in coolingonly operation, it is possible to produce free hot
water. The basement, the structure and the panelling are in steel treated with polyester anti-corrosion
paint.
Version
NRL_H Standard heat pumps
NRL_HL Standard heat pumps Low noise version
NRL_HA High efficiency version
NRL_HE High efficiency version Low noise version
Operating limits: Work at full load down to
-15C external air temperature in winter season,
up to 46C in summer season. Hot water pro-

Night Mode is standard on all low noise versions.


For all other versions either the DCPX accessory
or J inverter fan must be specified to allow
Night Mode to operate.

Accessories

226

COMPATIBILITY with the VMF SYSTEM For


more information on the system refer to the
manual.

Accessory Compatibility
Mod. NRL
AER485P1
PGD1
AERWEB300
MULTICHILLER_PCO
(1)
(1)
(1)
(1)
(2)

DCPX

GP
AVX "00"
AVX "01...04"
AVX (P1-P2-P3-P4)

Vers.
Alls
Alls
Alls
Alls
H
HL
HA
HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE

0800

65
standard
66
standard
10 (x3)
260
701
704
702
705
703
706

0900

65
standard
66
standard
10 (x3)
260
707
710
708
711
709
712

1000

65
standard
66
standard
10 (x4)
260
713
716
714
711
715
712

1250

65
standard
68
standard
10 (x4)
350
713
719
717
720
718
721

1404

66
standard
68
standard
350
350
722
725
723
726
724
727

1504

66
standard
68
standard
350
350
722
730
728
731
729
732

1655

68
standard
68
standard
350
500
733
734
728
735
729
736

1800

68
standard
68
standard
350
500
730
737
728
738
732
736

Alls
H/HL
HA/HE
Alls

801
87
88

901
89
90

1001
91
92

1251
91
92

1404
92
92

1504
92
92

1655
93
93

1801
94
94

Accessories factory fitted only


DRE
RIF
PRM1

(1) DCPX Standard in the models with desuperheater; In the low noise versions; Not necessary fields with ventilarori inverter
(2) (x3)(x4) the numbre in brackets indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system
requirements.

Campo
1,2,3
4,5,6,7
8

X
9
H
10

D
11

L
A
E
12

R
S
V
13

J
14

Code
NRL
Size
0800-0900-1000-1250-1404-1504-1655-1800
Expansion valve:
Standard (leaving water temperature down to 4C)
Electronic expansion valve (leaving water temperature down
to 4C) contact head office for lower temperatures (3)
Model
Heat pumps
Heat recovery
Without recovery
With desuperheater (4)
Version
Standard
Standard in low noise operation
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans
Standard
Inverter
Power supply
400V/3/50Hz with circuit breakers

15-16
00
01
02
03
04
05
06
07
08
09
10
P1
P2
P3
P4

Hydronic kit (5)


Without hydronic kit
n1 low head pump and buffer tank
n2 low head pump and buffer tank
n1 high head pump and buffer tank
n2 high head pump and buffer tank
n1 low head pump and buffer tank (with holes for immersion heaters)
n2 low head pump and buffer tank (with holes for immersion heaters)
n1 low high pump and buffer tank (with holes for immersion heaters)
n2 low high pump and buffer tank (with holes for immersion heaters)
double hydraulic circuit
double hydraulic circuit with immersion heater
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump

(3) The option X is not compatible with the option D ( only for temperature lower than 4C)
(4) The desuperheater can be used exclusively in the cold operation
(5) The buffer tank with holes and supplementary electric heaters leave the factory with plastic protection caps. Before loading the system, if the installation of an electric
heater is not envisaged it is compulsory to replace the plastic caps.

227

Technical data
Mod. NRL

Vers.
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE

Cooling capacity

Total power input

EER

ESEER

Water flow rate

Total pressure drop

Heating capacity
Total power input
COP
Water flow rate
Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

0800
200
183
210
193
82
90
74
82
2.44
2.02
2.84
2.36
3.85
3.79
4.01
3.92
34572
31648
36292
33368
46
39
54
47
228
234
76
75
3.00
3.11
39044
40076
61
68

0900
221
199
238
212
94.8
106
83.1
94.6
2.33
1.88
2.86
2.24
3.66
3.66
3.90
3.87
38184
34400
41108
36636
45
37
56
45
257
264
86.3
84.5
2.98
3.13
44032
45236
61
68

1000
261
236
260
230
102
113
95.1
107.93
2.55
2.09
2.73
2.13
3.67
3.66
3.82
3.78
45064
40764
44892
39732
49
41
54
43
295
295
97.5
94.7
3.02
3.11
50396
50396
65
68

1250
299
264
313
283
121
136
110
123
2.46
1.93
2.83
2.30
3.63
3.56
3.96
3.93
51600
45580
54180
48848
57
45
61
50
342
346
113
112
3.03
3.09
58480
59168
78
75

1404
332
301
350
318
141
155
127
141
2.35
1.94
2.74
2.25
3.50
3.42
3.80
3.77
57276
51944
60372
54868
40
33
48
40
386
390
127
126
3.02
3.10
66048
66736
54
58

1504
366
331
386
354
160
175
144
159
2.28
1.89
2.67
2.22
3.44
3.39
3.72
3.66
63124
57104
66736
61060
40
33
48
41
429
435
143
141
3.00
3.08
73444
74476
55
60

1655
421
372
435
397
168
188
152
169
2.51
1.98
2.85
2.34
3.45
3.39
3.74
3.72
72756
64156
75164
68456
47
37
54
45
470
486
157
155
2.99
3.13
80496
83248
59
66

1800
452
396
470
424
180
204
164
183
2.50
1.94
2.87
2.31
3.53
3.37
3.71
3.74
78088
68284
81184
73272
45
35
54
44
505
526
168
166
3.00
3.17
86516
89956
58
66

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.

Vers.

0800

0900

1000

1250

1404

1504

1655

1800

249
269
235
251
227
227
231
231
282
290
616
624

286
308
273
292
261
261
265
282
312
320
646
654

305
328
286
306
279
279
282
282
349
357
683
691

319
348
304
324
290
290
293
293
398
406
666
674

4
2

4
2

5
2

6
2

1
4"

1
4"

1
4"

1
4"

Electrical data
Total input current cooling mode

Total input current heating mode

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

Maximum current (FLA)


Starting current (LRA)

H
HL
HA
HE
H
HL
HA
HE
H/HL
HA/HE
H/HL
HA/HE

A
A
A
A
A
A
A
A
A
A
A
A

142
153
136
145
136
136
138
138
173
177
348
352

166
177
158
169
156
156
157
157
195
199
404
408

189
200
180
192
179
179
177
177
221
221
430
430

208
226
196
211
193
193
197
197
265
274
533
542

Alls
Alls
Alls
Alls

type
n
n
type

4
2

4
2

4
2

4
2

(in/out)

type
n

Compressors
Compressors
Circuits
Refrigerant
System side exchanger
Exchanger
hydraulic connections

(1)

(1) Data of the versions without hydronic module integrated

228

Scroll

R410A
Plate
1
3"

1
3"

1
3"

1
3"

Vers.
Fans standard
Fans

Alls
H
HL
HA
HE
H
HL
HA
HE

Air flow rate cooling mode

Number fans

0800

0900

1000

m3/h
m3/h
m3/h
m3/h
n
n
n
n

64500
45200
85600
59920
3
3
4
4

63750
44600
84600
59220
3
3
4
4

85600
59900
83600
60610
4
4
4
4

l
kPa

700

700
700
700
700
700
700
For more information, refer to the technical documentation

700

db(A)
db(A)
db(A)
db(A)
db(A)
db(A)
db(A)
db(A)
V/ph/Hz

88.5
85.5
88.5
83.0
56.5
53.5
56.5
51.0

88.5
85.5
88.5
83.0
56.5
53.5
56.5
51.0

94.0
91.0
94.0
88.5
62.0
59.0
62.0
56.5

Hydronic kit
Buffer tank
Useful static pressure
Dati sonori
H
HL
HA
HE
H
HL
HA
HE

Sound power

Sound pressure
Power supply

1250

1404

Axial
80800
87400
56600
65500
126000 124200
88200
90000
4
4
4
4
6
6
6
6

90.5
87.5
88.5
83.5
58.5
55.5
56.5
51.0

93.5
91.0
90.5
88.0
91.5
91.0
86.0
85.5
61.5
59.0
58.5
56.0
59.5
59.0
54.0
53.5
400V/3/Hz

1504

1655

1800

86800
69400
122400
91800
4
4
6
6

124200
86900
168000
117600
6
6
8
8

122400
85700
165600
115920
6
6
8
8

90.5
87.5
91.5
85.0
58.5
55.5
58.5
53.0

92.0
89.0
92.0
86.5
60.0
57.0
60.0
54.5

Sound power (cooling mode)


Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure (cooling mode)
Sound pressure in free field, at 10m. distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
NRL_1000/1250 H-HL

NRL/0800/0900 H-HL

NRL_1250/1404/1504 HA-HE
1655/1800 H-HL

NRL_0800/0900/1000 HA-HE
NRL_1404/1504 H-HL

NRL_1655/1800 HA-HE

A
A

A
A

C
C

(mm) A

Width

(mm) B

Depth

(mm) C
(kg)

Vers.

800

900

1000

1250

1404

1504

1655

1800

H/HL
HA/HE
H/HL
HA/HE
H/HL
HA/HE
H
HL
HA
HE

1975
2450
1500
2200
4355
3400
1800
1800
2150
2160

1975
2450
1500
2200
4355
3400
1940
1950
2300
2310

1975
2450
1500
2200
5355
3400
2170
2180
2460
2470

1975
2450
1500
2200
5355
4250
2320
2320
2750
2760

2450
2450
2200
2200
4250
4250
2930
2940
2990
3000

2450
2450
2200
2200
4250
4250
3140
3150
3190
3200

2450
2450
2200
2200
4250
5750
3220
3230
3680
3690

2450
2450
2200
2200
4250
5750
3330
3340
3800
3810

Cod.: SNRLLSHUY.12 / 1502

U.M.

Height

Mod. NRL

Weight empty

C
B

Warning: the weights refer to versions without hydronic module integrated

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

229

NEW

NRB

Air/Water chillers for outdoor installation


Scroll compressors, plate heat exchangers and axial fans
Cooling capacity 2211047kW

0800/3600
only cooling

R410A
Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com
* Not certified model

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


MICROCHANNEL COIL
QUICK AND EASY INSTALLATION
NIGHT MODE

Characteristics
Unit with 2 refrigerant circuits designed to provide
Adjustment includes complete management of
maximum efficiency at full load, also ensuring
the alarms and their log.
high efficiency at partial loads and ensuring conti- - The presence of a programmable timer allows setnuity in case one of the circuits stops
ting time bands of operation and a possible
The full range uses aluminium microchannel
second set-point
coils, ensuring very high levels of efficiency. This
- The temperature control takes place with the inteallows using less refrigerant compared to traditiogral proportional logic, based on the water output
nal copper coils.
temperature.
The possibility of using the electronic thermostatic - Night Mode: it is possible to set a silenced operaVersions
valve brings significant benefits, in particular when
tion profile.
NRB_
Standard
the refrigerant is working at partial loads to the
Perfect for night operation, since it guarantees greNRB_L
Standard low noise
benefit of energy efficiency of the unit. It is supater acoustic comfort in the evenings, and a high
NRB_A High efficiency
plied as standard from size 18003600 optional
efficiency in the time of greater load.
NRB_E
High efficiency low noise
for all other sizes.
NRB_U Very high efficiency
Electrical heater for plate heat exchanger
Night Mode is standard on all low noise versions.
NRB_N Very high efficiency low noise
Possibility of integrated hydronic kit that encloses
For all other versions either the DCPX accessory
the main hydraulic components; it is available in
or J inverter fan must be specified to allow
Range of operation: Work up to 50C of outdoor air
different configurations with one or two pumps,
Night Mode to operate.
temperature at full load, depending on size and verwith different static pressures available
sion. For further details refer to the selection software/
technical documentation.
Microprocessor adjustment, with keyboard and
LCD display, for easy consultation and intervention on the unit via a menu available in several
languages.
Outdoor chillers for the production of chilled water
with high-efficiency scroll compressors, axial fans,
microchannel condenser coils, plate heat exchanger.
In the units (with desuperheater or total recovery)
there is also the possibility of producing hot water for
free. The base, the structure and the panels are made
of steel treated with polyester paint.

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;

230

AERWEB300-18G: Web server to monitor and


remote control max. 18 units in RS485 network with integrated GPRS modem;
PGD1: Remote control of the chiller operating
functions.
MULTICHILLER_PCO: Control system for
multiple parallel installed constant flow chillers providing individual chiller on/off and
control capability.
DCPX: Device for condensation temperature
control, with continuous speed modulation
of fans by using a pressure transducer.
Standard in option low noise version or with
desuperheater.
AVX: Spring anti-vibration mounts.

FL: flow switch


Accessories factory fitted only
DRE: Electronic soft starter which reduces
starting current.
RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current).
GP: Coil guards
COMPATIBILITY with the VMF SYSTEM
For more information on the system refer to the
manual.

Compatibility of accessories
Mod. NRB
AER485P1
AERWEB300
PGD1
MULTICHILLER_PCO
DCPX
*
FL
AVX
(1)

vers.

Accessories factory fitted only


DRENRB

L
A
RIF
E
U
N
GP
*

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

0800
0800
0800
0800
0800
0800
0801

0900
0900
0900
0900
0900
0900
0901

1000
1000
1000
1000
1000
1000
1001

1100
1100
1100
1100
1101
1101
1101

1200
1200
1200
1200
1201
1201
1201

1400
1400
1400
1400
1401
1401
1401

1600
1600
1601
1601
1601
1601
1601

1800
1800
1800
1800
1800
1800

2000
2000
2000
2000
2000
2000

2200
2200
2200
2200
2200
2200

2400
2400
2400
2400
2400
2400

2600
2600
2600
2600
2600
2600

2800
2800
2800
2800
2800
2800

3000
3000
3000
3000
3000
3000

3200
3200
3200
3200
3200
3200

3400
3400
3400
3400
3400
3400

3600
3600
3600
3600
3600
3600

* Accessories to be defined for compatibility


(1) Refer to the technical documentation

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7

Y
X
Z
9

C
10

D
T
11

L
A
E
U
N
12

O
R
S
13

M
J
14

Description
NRB
Sizes (2)
0800-0900-1000-1100-1200-1400-1600-1800-20002200-2400-2600-2800-3000-3200-3400-3600
Operational limits
Standard (temperature of water produced up to +4 C)(3)
Low temperature (temperature of water produced from
+4C a -8C) (3)
Electronic thermostatic valve
(temperature of water produced up to +4 C)
Low temperature electronic thermostatic valve
(temperature of water produced from +4C a -8C)
Model
Cooling Only
Motor condensing unit (4)
Heat recovery
Without heat recovery
With desuperheater (4)
With total recovery (4)
Version
Standard
Low noise Standard
High efficiency
Low noise high efficency
Very high efficiency
Low noise very high efficiency
Coils
Aluminium microchannel
Painted aluminium microchannel
Copper - Copper
Copper - Tinned
Fans
Standard
increased
Inverter
Power supply
400V/3/50Hz with fuses

15-16

(2) The availability of models is to be agreed with the Technical Sales


(3) Sizes from 18003600 standard with the electronic thermostatic valve
(4) The motor condensing units are not configurable with option Y/X/Z
The models with total recovery "D/T" are not configurable with Y/Z and with vers. "C"
(5) All hydronic kit (from PA to BJ) are not compatible for the following sizes and versions with heat
recovery "T":
- 0800 - 0900 - 1000 - 1100 versions ""
- 0800 - 0900 versions "A"
- 0800 - 0900 versions "L"
(6) All hydraulic kit with pump / and buffer tank (from AA to BJ) are not compatible for all sizes and versions
with heat recovery "T"

Integrated hydronic kit


00 Without hydronic kit
With n1 pump: (5)
PA Pump A
PB Pump B
PC Pump C
PD Pump D
PE Pump E
PF Pump F
PG Pump G
PH Pump H
PI Pump I
PJ Pump J
With n2 pump: (5)
DA Pump A and Stand-by pump
DB Pump B and Stand-by pump
DC Pump C and Stand-by pump
DD Pump D and Stand-by pump
DE Pump E and Stand-by pump
DF Pump F and Stand-by pump
DG Pump G and Stand-by pump
DH Pump H and Stand-by pump
DI Pump I and Stand-by pump
DJ Pump J and Stand-by pump
With n 1 pump and buffer tank: (5)(6)
AA Pump A and buffer tank
AB Pump B and buffer tank
AC Pump C and buffer tank
AD Pump D and buffer tank
AE Pump E and buffer tank
AF Pump F and buffer tank
AG Pump G and buffer tank
AH Pump H and buffer tank
AI Pump I and buffer tank
AJ Pump J and buffer tank
With n 2 pumps and buffer tank: (5)(6)
BA Pump A with Stand-by pump and buffer tank
BB Pump B with Stand-by pump and buffer tank
BC Pump C with Stand-by pump and buffer tank
BD Pump D with Stand-by pump and buffer tank
BE Pump E with Stand-by pump and buffer tank
BF Pump F with Stand-by pump and buffer tank
BG Pump G with Stand-by pump and buffer tank
BH Pump H with Stand-by pump and buffer tank
BI Pump I with Stand-by pump and buffer tank
BJ Pump J with Stand-by pump and buffer tank

231

Technical Data
Mod NRB

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

Cooling
capacity

Total input
power

EER

ESEER

Water flow
rate

Total
pressure
drop

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

0800

0900

1000

1100

1200

1400

1600

1800

2200

2400

2600

2800

3000

3200

3400

3600

221
217
224
219
227
227
73
73
71
70
69
69
3,02
2,97
3,17
3,14
3,30
3,32
4,16
4,23
4,32
4,33
4,37
4,48
38160
37360
38600
37750
39190
39210
46
25
27
19
20
20

244
237
252
248
257
260
83
86
81
79
78
79
2,93
2,76
3,11
3,12
3,31
3,30
4,07
4,09
4,23
4,30
4,39
4,44
42120
40940
43440
42770
44360
44840
55
20
22
23
25
25

270
272
283
275
286
284
94
92
90
89
87
86
2,87
2,96
3,14
3,10
3,30
3,29
4,00
4,22
4,27
4,27
4,37
4,44
46550
46960
48860
47360
49350
49030
38
27
30
20
21
21

299
307
326
321
329
327
110
107
105
102
99
99
2,71
2,86
3,11
3,14
3,31
3,32
3,84
4,15
4,23
4,33
4,39
4,48
51620
52990
56140
55330
56750
56430
45
24
27
27
29
28

352
343
361
358
369
367
117
123
115
115
112
112
3,00
2,80
3,13
3,12
3,31
3,28
4,14
4,11
4,25
4,29
4,38
4,42
60800
59200
62190
61750
63670
63300
44
29
32
21
23
23

404
390
411
403
414
412
135
139
132
130
126
125
2,98
2,81
3,12
3,10
3,28
3,28
4,12
4,12
4,24
4,27
4,35
4,42
69720
67320
70870
69420
71380
70980
39
23
25
27
28
28

438
438
461
454
466
465
155
152
148
144
141
140
2,82
2,88
3,13
3,15
3,31
3,31
3,96
4,17
4,25
4,33
4,39
4,47
75600
75460
79580
78330
80370
80240
46
30
34
26
27
27

510
559
596
497
554
607
518
575
632
514
568
636
528
593
654
521
578
645
176
194
217
173
192
214
166
183
203
165
183
203
160
179
198
158
176
195
2,90
2,88
2,75
2,87
2,89
2,84
3,12
3,13
3,11
3,12
3,10
3,13
3,31
3,31
3,31
3,30
3,28
3,31
4,04
4,02
3,88
4,16
4,18
4,14
4,24
4,26
4,23
4,29
4,27
4,31
4,39
4,39
4,39
4,45
4,42
4,47
88010 96580 103000
85760 95600 104710
89370 99160 109010
88560 97950 109670
91100 102250 112740
89790 99680 111130
40
47
53
28
37
36
30
39
39
33
33
22
35
36
23
34
34
23

2000

674
665
696
687
716
702
236
234
223
221
215
213
2,85
2,84
3,12
3,10
3,32
3,29
3,98
4,14
4,24
4,27
4,41
4,44
116350
114690
120100
118450
123390
120920
52
44
48
25
27
26

719
726
756
740
764
748
256
247
240
237
229
229
2,81
2,94
3,14
3,13
3,33
3,27
3,94
4,21
4,28
4,31
4,42
4,40
124240
125170
130380
127560
131760
128990
58
28
30
30
32
30

784
769
804
793
814
803
270
270
256
255
249
247
2,90
2,85
3,14
3,10
3,27
3,26
4,04
4,14
4,27
4,27
4,33
4,38
135450
132530
138690
136720
140330
138510
60
31
34
34
36
35

829
833
865
856
877
865
293
285
277
275
266
263
2,83
2,93
3,12
3,12
3,30
3,28
3,97
4,20
4,25
4,29
4,38
4,42
142970
143570
149210
147660
151290
149130
36
30
32
33
35
34

878
885
927
910
939
925
315
307
297
291
282
283
2,79
2,88
3,12
3,13
3,33
3,27
3,92
4,17
4,24
4,31
4,41
4,41
151500
152590
159850
156920
161950
159500
39
34
38
38
40
39

943
950
978
963
997
971
329
323
314
310
303
301
2,86
2,94
3,11
3,10
3,30
3,22
4,00
4,21
4,23
4,26
4,37
4,33
162790
163960
168810
166120
172070
167560
46
39
41
41
44
42

996
1002
1024
1017
1047
1027
355
348
330
328
320
319
2,80
2,88
3,10
3,10
3,28
3,22
3,93
4,17
4,21
4,27
4,34
4,32
171800
172820
176730
175460
180640
177270
43
43
45
46
49
47

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
GENERAL DATA
Electrical data

Total input
current

(1)
(1)
(1)
(1)
(1)
(1)

L
A
E
U
N

Compressors
Compressors
Circuits
Refrigerant
System side exchanger
exchanger
Fans standard

fans

Air flow rate


cooling mode

L
A
E
U
N

L
A
E
U
N

A
A
A
A
A
A
type
n
n
type
type
n
type
n
n
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

128
123
124
119
124
118

143
142
140
135
138
135

160
154
159
149
153
147

186
179
182
172
176
167

202
203
198
193
196
189

230
232
224
216
218
209

261
251
252
240
244
234

300
290
284
275
278
264

367
359
349
343
348
329

405
390
386
373
377
360

434
413
418
397
401
385

459
449
442
426
432
412

498
479
476
460
463
442

535
513
513
488
494
475

563
545
542
521
528
506

606
585
568
549
556
536

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

5
2

6
2

6
2

6
2

6
2

6
2

4
4
4
6
6
8
64000
46000
64000
69000
96000
92000

4
4
4
6
6
8
64000
46000
64000
69000
96000
92000

6
6
6
8
8
10
96000
69000
96000
92000
128000
115000

6
8
8
10
10
12
96000
92000
128000
115000
160000
138000

8
8
8
12
12
14
128000
92000
128000
138000
192000
161000

330
319
316
306
312
295
scroll
4
2
R410A
plate
1
axial
8
10
10
12
12
14
128000
115000
160000
138000
192000
161000

8
10
10
14
12
16
128000
115000
160000
161000
224000
184000

10
12
12
14
14
16
160000
138000
192000
161000
224000
184000

10
14
14
16
16
18
160000
161000
224000
184000
256000
207000

12
14
14
16
16
18
192000
161000
224000
184000
256000
207000

12
14
14
18
18
20
192000
161000
224000
207000
288000
230000

12
16
16
20
20
22
192000
184000
256000
230000
320000
253000

14
16
16
20
20
22
224000
184000
256000
230000
320000
253000

14
16
16
20
20
22
224000
184000
256000
230000
320000
253000

88
83
88
85
90
86

88
83
88
85
90
86

90
86
90
86
91
88

90
86
91
88
93
88

92
88
92
89
94
90

95
90
96
91
96
92

95
91
96
92
97
93

96
91
96
92
97
93

96
92
96
93
98
93

96
92
97
93
98
94

96
93
97
93
98
94

96
93
97
93
98
94

4
4
6
6
6
6
6
6
6
6
8
8
6
8
8
8
10
10
64000 64000 96000
69000 69000 69000
96000 96000 96000
69000 92000 92000
96000 128000 128000
92000 115000 115000

Sound data

Sound power

Power supply

L
A
E
U
N

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

88
85
90
85
90
86

88
85
90
86
91
88

90
85
90
86
91
88

92
89
94
89
95
90
400V/3/50Hz

93
90
94
91
96
91

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

232

Dimensions (mm)
(1) Versions with buffer tank
NRB08001100 (1)
NRB08000900 L/A (1)

NRB08001100
NRB08000900 L/A

NRB12001600
NRB10001400 L/A
NRB08001000 E/U

NRB18003600
NRB16003600 L/A
NRB11003600 E/U
NRB08003600 N

C
C

Mod. NRB
Height
Width

(mm)
(mm)

A
B

Depth

(mm)

Weight

(kg)

Vers.
all
all

L
A
E
U
N

L
A
E
U
N

0800

0900

1000

1100

1200

1400

1600

1800

2000

2450
2200
2780 (1)
2780 (1)
2780 (1)
3970
3970
4760
2240
2260
2260
2720
2720
3220

2450
2200
2780 (1)
2780 (1)
2780 (1)
3970
3970
4760
2280
2320
2320
2760
2760
3270

2450
2200
2780 (1)
3970
3970
3970
3970
4760
2350
2800
2800
2840
2840
3340

2450
2200
2780 (1)
3970
3970
4760
4760
5950
2390
2870
2870
3370
3370
3770

2450
2200
3970
3970
3970
4760
4760
5950
2880
2910
2910
3440
3440
3840

2450
2200
3970
3970
3970
4760
4760
5950
2930
2970
2970
3460
3460
3870

2450
2200
3970
4760
4760
5950
5950
7140
2960
3490
3490
3940
3940
4290

2450
2200
4760
4760
4760
7140
7140
8330
3580
3630
3630
4390
4390
4840

2450
2200
4760
5950
5950
7140
7140
8330
3660
4110
4110
4510
4510
4970

(1) Depth of the models without hydronic kit or pumps, for models with storage depth is 3970mm

Mod. NRB
Height
Width

(mm)
(mm)

A
B

Depth

(mm)

(kg)

2200

2400

2600

2800

3000

3200

3400

3600

2450
2200
4760
5950
5950
8330
7140
9520
3740
4230
4230
5200
5200
5600

2450
2200
5950
7140
7140
8330
8330
9520
4270
4670
4670
5280
5280
5680

2450
2200
5950
8330
8330
9520
9520
10710
4500
5510
5510
5910
5910
6310

2450
2200
7140
8330
8330
9520
9520
10710
5150
5760
5760
6160
6160
6560

2450
2200
7140
8330
8330
10710
10710
11900
5390
5910
5910
6700
6700
7010

2450
2200
7140
9520
9520
11900
11900
13090
5470
6390
6390
7140
7140
7540

2450
2200
8330
9520
9520
11900
11900
13090
6000
6520
6520
7220
7220
7620

2450
2200
8330
9520
9520
11900
11900
13090
6150
6600
6600
7300
7300
7700

Cod.: SNRBUY.01 / 1501

Weight

Vers.
all
all

L
A
E
U
N

L
A
E
U
N

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

233

NEW

NRB
0800/3600

Reversible heat pumps Air/Water for outdoor installation


Scroll compressors, plate heat exchangers and axial fans
Cooling capacity 196969kW
Heating capacity 2101009kW

Heat pumps

R410A
Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


QUICK AND EASY INSTALLATION
NIGHT MODE
Characteristics
Adjustment includes complete management of
Unit with 2 refrigerant circuits designed to provide
Outdoor heat pump unit for the production of chilthe alarms and their log.
maximum efficiency at full load, also ensuring
led / hot water, with high-efficiency scroll compreshigh efficiency at partial loads and ensuring conti- - The presence of a programmable timer allows setsors, axial fans, plate heat exchanger.
ting time bands of operation and a possible
nuity in case one of the circuits stops.
In the units (with desuperheater) there is also the possecond set-point
sibility of producing hot water for free. The base, the The possibility of using the electronic thermostatic
valve brings significant benefits, in particular when - The temperature control takes place with the intestructure and the panels are made of steel treated
gral proportional logic, based on the water output
the refrigerant is working at partial loads to the
with polyester paint.
temperature.
benefit of energy efficiency of the unit. It is sup- Night Mode: it is possible to set a silenced operaplied as standard from size 18003600 optional
Version
tion profile.
for all other sizes.
NRB_H Standard
Perfect for night operation, since it guarantees gre Electrical heater for plate heat exchanger
NRB_HL Low noise
ater acoustic comfort in the evenings, and a high
Possibility of integrated hydronic kit that encloses
NRB_HA High efficiency
efficiency in the time of greater load.
the main hydraulic components; it is available in
NRB_HE High efficiency low noise
different configurations with one or two pumps,
Night Mode is standard on all low noise versions.
with different available static pressures
Range of operation: Work up to 50C of outdoor air
For all other versions either the DCPX accessory
temperature at full load, depending on size and ver- Microprocessor adjustment, with keyboard and
or J inverter fan must be specified to allow
sion. For further details refer to the selection software/
LCD display, for easy consultation and intervenNight Mode to operate.
technical documentation.
tion on the unit via a menu available in several
languages.

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and

234

remote control max. 18 units in RS485 network with integrated GPRS modem;
PGD1: Remote control of the chiller operating
functions.
MULTICHILLER_PCO: Control system for
multiple parallel installed constant flow chillers providing individual chiller on/off and
control capability.
DCPX: Device for condensation temperature
control, with continuous speed modulation
of fans by using a pressure transducer.
Standard in option low noise version or with
desuperheater.
AVX: Spring anti-vibration mounts.
FL: flow switch

Accessories factory fitted only


DRE: Electronic soft starter which reduces
starting current.
RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current).
GP: Coil guards
COMPATIBILITY with the VMF SYSTEM
For more information on the system refer to the
manual.

Compatibility of accessories
Mod. NRBH
AER485P1
AERWEB300
PGD1
MULTICHILLER_PCO
FL
DCPX
*
AVX
(1)

vers.

Accessories factory fitted only


DRENRB
H
HL
RIF
HA
HE
GP
*

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

0800
0800
0800
0800
0800

0900
0900
0900
0900
0900

1000
1000
1000
1000
1000

1100
1100
1100
1100
1101

1200
1200
1200
1200
1201

1400
1400
1400
1400
1401

1600
1600
1601
1601
1601

1800
1800
1800
1800

2000
2000
2000
2000

2200
2200
2200
2200

2400
2400
2400
2400

2600
2600
2600
2600

2800
2800
2800
2800

3000
3000
3000
3000

3200
3200
3200
3200

3400
3400
3400
3400

3600
3600
3600
3600

* Accessories to be defined for compatibility


(1) Refer to the technical documentation

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7

X
9
H
10

D
11

L
A
E
12

R
S
V
13

J
14

15-16
00
PA
PB
PC
PD
PE
PF

Description
NRB
Size (1)
0800-0900-1000-1100-1200-1400-1600-1800-20002200-2400-2600-2800-3000-3200-3400-3600
Operational limits
Standard (temperature of water produced up to +4 C) (2)
Electronic thermostatic valve
(temperature of water produced up to +4 C)
Model
Reversible heat pump
Heat recovery
Without heat recovery
With desuperheater (3)
Version
Standard
Low noise Standard
High efficiency
Low noise high efficency
Coils
Aluminium
Copper - Copper
Copper - Tinned
Aluminium painted
Fans
Standard
Inverter
Power supply
400V/3/50Hz with breakers
Integrated hydronic kit
Without hydronic kit
With n1 pump:
Pump A
Pump B
Pump C
Pump D
Pump E
Pump F

PG
PH
PI
PJ
DA
DB
DC
DD
DE
DF
DG
DH
DI
DJ
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
BA
BB
BC
BD
BE
BF
BG
BH
BI
BJ

Pump G
Pump H
Pump I
Pump J
With n2 pump:
Pump A and Stand-by pump
Pump B and Stand-by pump
Pump C and Stand-by pump
Pump D and Stand-by pump
Pump E and Stand-by pump
Pump F and Stand-by pump
Pump G and Stand-by pump
Pump H and Stand-by pump
Pump I and Stand-by pump
Pump J and Stand-by pump
With n 1 pump and buffer tank:
Pump A and buffer tank
Pump B and buffer tank
Pump C and buffer tank
Pump D and buffer tank
Pump E and buffer tank
Pump F and buffer tank
Pump G and buffer tank
Pump H and buffer tank
Pump I and buffer tank
Pump J and buffer tank
With n 2 pumps and buffer tank:
Pump A with Stand-by pump and buffer tank
Pump B with Stand-by pump and buffer tank
Pump C with Stand-by pump and buffer tank
Pump D with Stand-by pump and buffer tank
Pump E with Stand-by pump and buffer tank
Pump F with Stand-by pump and buffer tank
Pump G with Stand-by pump and buffer tank
Pump H with Stand-by pump and buffer tank
Pump I with Stand-by pump and buffer tank
Pump J with Stand-by pump and buffer tank

(1) The availability of models is to be agreed with the Technical Sales


(2) Sizes from 18003600 standard with the electronic thermostatic valve
(3) The desuperheater can be used exclusively in the cold operation

235

Dati tecnici
Mod NRBH
Cooling
capacity
Total input
power

EER

ESEER

Water flow
rate
Total
pressure
drop
Heating
capacity

Total input
power

COP

Water flow
rate
Total
pressure
drop

H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

196
198
206
209
74
75
72
67
2,64
2,63
2,87
3,11
3,87
3,97
4,03
4,26
33700
34020
35430
36020
34
14
15
15
216
210
215
224
70
67
67
69
3,07
3,13
3,22
3,23
37070
36130
36890
38470
42
15
16
17

218
228
244
241
86
79
78
77
2,53
2,89
3,11
3,12
3,78
4,18
4,20
4,27
37450
39150
41890
41540
24
18
21
20
238
251
255
258
78
80
79
80
3,06
3,15
3,21
3,21
40900
43100
43800
44430

251
247
267
264
92
90
88
85
2,74
2,75
3,02
3,11
3,94
4,07
4,14
4,26
43220
42560
45860
45490
32
15
18
18
276
275
279
284
90
87
87
88
3,08
3,15
3,22
3,23
47420
47230
48040
48850

279
275
297
294
108
106
102
98
2,58
2,59
2,90
3,00
3,82
3,94
4,05
4,19
47930
47290
51010
50580
26
19
22
22
307
305
311
317
100
99
97
98
3,07
3,09
3,20
3,22
52730
52500
53480
54560

314
301
329
326
120
123
117
112
2,62
2,44
2,81
2,90
3,85
3,83
3,99
4,13
53940
51750
56580
56140
33
14
17
16
345
335
341
350
112
108
106
109
3,07
3,09
3,22
3,21
59290
57540
58730
60150

28

38

32

40

22
23
23

19
20
20

23
24
25

17
18
19

353
359
385
377
142
133
129
125
2,50
2,70
2,98
3,01
3,75
4,03
4,11
4,20
60750
61700
66220
64890
31
20
23
22
367
395
401
404
122
126
125
126
3,01
3,13
3,22
3,20
63120
67910
69060
69450
34
24
25
25

388
392
425
432
156
153
147
139
2,50
2,55
2,89
3,10
3,75
3,92
4,04
4,26
66770
67380
73060
74270
37
18
21
21
414
432
439
459
137
137
137
143
3,02
3,16
3,21
3,21
71140
74230
75590
79000
42
21
22
24

456
453
488
489
173
169
164
157
2,64
2,68
2,98
3,11
3,86
4,02
4,11
4,27
78400
77950
83880
84050
32
23
27
27
479
498
507
522
157
158
157
163
3,05
3,15
3,22
3,21
82450
85690
87180
89730
36
28
29
31

501
494
537
540
193
194
185
177
2,59
2,55
2,91
3,04
3,83
3,92
4,06
4,22
86140
85040
92440
92820
38
23
27
27
529
544
554
573
174
173
172
177
3,03
3,14
3,23
3,24
90980
93550
95310
98560
42
28
29
31

567
552
600
597
211
209
201
192
2,69
2,64
2,98
3,10
3,90
3,98
4,11
4,26
97600
94880
103240
102630
37
28
34
33
593
611
621
636
194
195
194
198
3,06
3,13
3,21
3,21
102060
105020
106870
109320
40
35
36
38

615
592
651
647
231
234
222
215
2,66
2,53
2,93
3,01
3,88
3,90
4,07
4,19
105710
101870
111890
111280
42
17
21
21
645
655
667
685
211
209
207
212
3,06
3,14
3,22
3,23
110920
112680
114790
117800
46
21
22
23

652
650
708
698
253
246
237
231
2,58
2,64
2,98
3,02
3,82
3,99
4,11
4,20
112230
111870
121700
120080
50
21
25
24
691
719
731
742
228
228
227
230
3,03
3,15
3,22
3,23
118790
123590
125750
127710
56
26
26
27

716
680
744
734
266
270
258
251
2,69
2,52
2,89
2,93
3,90
3,90
4,04
4,14
123220
117020
128000
126210
48
23
28
27
752
759
772
786
245
244
240
245
3,07
3,11
3,22
3,21
129380
130470
132860
135130
53
29
30
31

766
748
814
798
291
285
274
269
2,63
2,62
2,97
2,96
3,85
3,97
4,10
4,17
131750
128570
139970
137180
31
23
28
27
797
826
841
850
261
265
261
265
3,06
3,12
3,22
3,21
137170
142140
144720
146150
33
28
30
30

804
783
858
840
316
310
296
290
2,55
2,53
2,90
2,90
3,79
3,90
4,05
4,12
138240
134690
147490
144410
34
25
31
29
838
871
887
897
276
280
275
280
3,04
3,11
3,22
3,21
144180
149760
152600
154300
37
31
33
33

868
847
926
902
328
327
312
308
2,65
2,59
2,97
2,93
3,87
3,95
4,10
4,14
149300
145610
159300
155190
37
29
35
33
909
939
956
962
296
300
297
300
3,07
3,13
3,22
3,21
156330
161500
164480
165520
40
36
37
38

913
881
969
943
353
352
334
327
2,58
2,50
2,91
2,88
3,82
3,88
4,06
4,11
157050
151550
166720
162200
34
32
38
36
950
983
1002
1009
312
317
312
315
3,05
3,10
3,21
3,20
163400
169100
172340
173610
37
39
41
41

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C

GENERAL DATA
Electrical data
Total input
current
cooling mode
Total input
current
heating mode

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

H
HL
HA
HE
H
HL
HA
HE

Compressors
Compressors
Circuits
Refrigerant
System side exchanger
exchanger
Fans standard
Fans

Air flow rate


cooling mode

H
HL
HA
HE
H
HL
HA
HE

A
A
A
A
A
A
A
A
type
n
n
type
type
n
type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

Heating: (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C
b.s./6C b.u.

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

131
126
127
115
125

150
133
141
132
138

163
150
157
144
158

189
176
179
164
175

207
203
203
187
195

242
220
225
208

263
252
254
230

296
280
285
261

331
321
321
296

365
347
352
322

398
390
389
362

437
409
416
387

456
446
448
417

504
473
479
449

545
515
515
483

564
543
546
515

606
585
582
547

119
120
122

139
142
140

152
155
153

171
172
170

187
187
188

212
216
219
216

236
234
240
244

274
272
277
278

304
299
303
305

340
336
342
341

369
363
368
367

397
394
401
396

427
420
421
420

458
457
460
456

484
484
485
482

519
518
526
517

549
549
550
544

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

4
2

5
2

6
2

6
2

6
2

6
2

6
2

6
8
8
10
120000
120000
160000
150000

6
8
8
12
120000
120000
160000
180000

8
10
10
14
160000
150000
200000
210000

10
12
12
16
200000
180000
240000
240000

10
12
12
16
200000
180000
240000
240000

12
14
14
18
240000
210000
280000
270000

12
14
14
18
240000
210000
280000
270000

14
16
16
20
280000
240000
320000
300000

14
16
16
20
280000
240000
320000
300000

14
18
18
22
280000
270000
360000
330000

14
18
18
22
280000
270000
360000
330000

92
86
93
87

92
86
93
88

93
88
94
89

94
90
95
92

95
91
96
92

95
91
96
92

96
92
97
93

96
92
97
93

96
92
97
93

96
92
97
93

4
4
4
6
80000
60000
80000
90000

4
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
80000 120000 120000 120000
90000 90000 90000 90000
120000 120000 120000 120000
120000 120000 120000 120000

scroll
4
2
R410A
plate
1
axial
8
10
10
14
160000
150000
200000
210000

Sound data
Sound power
Power supply

H
HL
HA
HE

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

90
83
90
85

90
85
92
86

92
85
92
86

92
85
92
86

92
85
92
86

93
88
94
90
400V/3/50Hz

94
90
95
91

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

236

Dimensions (mm)
(1) Versions with buffer tank
NRB0800 H/HL/HA
NRB0900 H

NRB0800 H/HL/HA
NRB0900 H

NRB0800 HE
NRB09001200 HL/HA
NRB10001600 H

NRB09003600 HE
NRB14003600 HL/HA
NRB18003600 H

Height
Width
Depth

H
H
H
HL
HA
HE

A
B
C
C
C
C

0800

0900

1000

1100

1200

1400

1600

1800

2000

2200

2400

2600

2450
2200
2780(1)
2780 (1)
2780 (1)
3970

2450
2200
2780 (1)
3970
3970
4760

2450
2200
3970
3970
3970
4760

2450
2200
3970
3970
3970
4760

2450
2200
3970
3970
3970
4760

2450
2200
3970
4760
4760
5950

2450
2200
3970
4760
4760
7140

2450
2200
4760
5950
5950
8330

2450
2200
4760
5950
5950
8330

2450
2200
5950
7140
7140
9520

2450
2200
5950
7140
7140
9520

2450
2450
2450
2450
2450 2450
2200
2200
2200
2200
2200 2200
7140
7140
8330
8330
8330 8330
8330
8330
9520
9520 10710 10710
8330
8330
9520
9520 10710 10710
10710 10710 11900 11900 13090 13090

2800

3000

3200

3400

3600

Cod.: SNRBHY.01 / 1503

(1) Depth of the models without hydronic kit or pumps, for models with storage depth is 3970mm

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

237

NRK

0280/0700
heat pumps

Reversible heat pumps


Air/Water outdoor installation
Axial fans and scroll compressor
Cooling capacity 36148kW
Heating capacity 42175kW

R410A
AERMEC
partecipates in the EUROVENT
programme for: LCP Check ongoing
validity of certificate online:
www.eurovent-certification.com

PRODUCTION OF HOT WATER UP TO 65C


HEATING OPERATION WITH EXTERNAL
TEMPERATURES DOWN TO -20C
OPTIMIZED FOR OPERATION IN HEATING MODE
HIGH EFFICIENCY EVEN AT PART LOAD
OPTION VERSION WITH BUILT-IN HYDRONIC KIT
Characteristics
Reversible heat pumps
Versions
NRK_HA High efficiency version
NRK_HE High efficiency Low noise version
Operational limits (1)
- max. external air temperature 48C
in cooling mode
- Maximum leaving water temperature 65C
in fheating mode
2 refrigerant circuits
High efficiency scroll compressors with low
power input, with steam injection
Heat exchangers optimised to benefit from
the excellent heat transfer characteristics of
R410A.
flow switch as standard supply

- Condensing control in summer with a 0-10


Water filter
V modulating signal based on pressure and
Low and high pressure transducers
compensated for external air temperature
The built-in hydronic kit alredy contains the
- Automatic rotation of compressors and
main water circuit components; it is available
pumps based on operating hours
with single or twin in line, for archieving both
- Load limiting safety control
low or high head, and buffer tank.
Metallic protective cabinet with anti-corro Axial fans for extremely quiet operation.
sion polyester paint
Availables fans high static pressure and
equipped with inverter technology, with availble high head
Units fitted as standard with fan speed controller (DCPX).
Microprocessor controls.
- Control from the leaving water temperature,
with the possibility of selecting control of
the entering water temperature.

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: The AERWEB option allows
remote control of a chiller through a standard PC and an ethernet connection with a
standard browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control maximum 6 units on RS485
network;
AERWEB300-18: Web server to monitor and
remote control maximum 18 units on RS485
network;
AERWEB300-6G: Web server to monitor and
remote control maximum 6 units on RS485
network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor

238

and remote control maximum 18 units on


RS485 network with integrated GPRS
modem.
PGD1: Simplified remote panel. Allows control of basic unit functions and alarm notification.
MULTICHILLER_PCO: Control system to
switch the individual chillers on and off, and
command them, in a system in which several units are installed in parallel, always
ensuring a constant delivery to the evaporators.
GP: Protection grille protects the external
coil from accidental damage.
VT Anti-vibration mounts to be installed
under the base of the unit.

Accessories factory fitted only


DRE: Electronic soft starter which reduces
starting current by about 26%.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current.
PRM1: It is a manual pressure switch electrically
wired in series with the existing automatic high
pressure switch on the compressor discharge
pipe.
COMPATIBILITY with the VMF SYSTEM For
more information on the system refer to the
manual.

Compatibility of accessories
Mod. NRK
AER485P1
AERWEB300
PGD1
MULTICHILLER_PCO
GP
VT (00)
VT (-P1-P2-P3-P4)
VT (01-02-03-04-05-06-07-08-09-10)

(1)

Vers.
All
All
All
All
All
All
All

0200

3
17
17
13

0280

3
17
17
13

0300

4
17
17
13

0330

4
17
17
13

0350

2(x2)
13
13
10

0500

2(x2)
13
13
10

0550

2(x2)
13
13
10

0600

2(x2)
13
13
10

0650

2(x3)
22
22
22

0700

2(x3)
22
22
22

All
All
All

201
55

281
56

301
54

331
57

351
65

501
58

551
59

601
60

651
61

701
61

Accessories factory fitted only


DRE
RIF
PRM1

(1) (x2)(x3) the number in brackets indicates the quantity to order

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7
8

9
H
10

D
11
A
E
12

R
S
V
13

M
J
14

15-16
00
01
02
03
04
05
06
07
08
P1
P2
P3
P4

Code
NRK
Size
0200-0280-0300-0330-0350-0500-0550-0600-0650-0700 (2)
Field of application
Termostatic expansion valve(3)
Model
Heat pumps
Heat recovery
Without recovery
With Desuperheater
Version
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans (4)
Standard
Increased
High static pressure Inverter
Alimentation
400V/3N/50Hz with circuit breakers
System integrated hydronic module (5)
without pumps or buffer tank
Buffer tank and n 1 low head pump
Buffer tank and n 2 low head pump
Buffer tank and n 1 high head pump
Buffer tank and n 2 high head pump
n1 low head pump and buffer tank (with holes for immersion heaters)
n2 low head pump and buffer tank (with holes for immersion heaters)
n1 low high pump and buffer tank (with holes for immersion heaters)
n2 low high pump and buffer tank (with holes for immersion heaters)
n 1 low head pump
n 2 low head pump
n 1 high head pump
n 2 high head pump

(2) The size 0200-0280-0300-0330 only available in low noise version "HL" and equipped with inverter fans as standard
(3) Leaving water temperature down to 4C
(4) Standard on/off fans for sizes from 0350 to 0700
Increased on/off fans, option for sizes from 0200 to 0330
Standard Inverter fans for sizes from 0200 to 0330, without useful static pressure
Inverter fan, option for sizes from 0350 to 0700 with useful static pressure
(5) The buffer tank with holes and supplementary electric heaters leave the factory with plastic protection caps. Before loading the system, if the installation of an electric
heater is not envisaged it is compulsory to replace the plastic caps

239

Technical Data
Mod. NRK Heat pumps
HA
HE
HA
HE
HA
HE
HA
HE
HA
HE
HA
HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE

Cooling capacity
Total input power
EER
ESEER
Water flow rate
Total pressure drop
Heating capacity
Total input power
COP
Water flow rate
Total pressure drop

kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
W/W
l/h
kPa

0200
35,5
11,7
3,03
3,61
6130
18
42,3
12,1
3,49
7173
24

0280
50,3
17,5
2,88
3,52
8668
17
59,8
17,1
3,49
10056
22

0300
59,3
19,6
3,03
3,62
10234
23
69,6
20,0
3,48
11738
30

0330
66,0
22,4
2,95
3,54
11377
19
78,4
22,5
3,48
13060
25

0350
75,3
74,2
25,4
27,7
2,96
2,68
3,56
3,47
12981
12799
23
22
88,0
25,5
3,45
15506
32

0500
88,6
87,2
29,6
32,5
3,00
2,69
3,63
3,54
15275
15032
26
25
104
30
3,44
18160
36

0550
101
100
34
38
2,94
2,61
3,60
3,51
17485
17172
32
30
119
35
3,43
20577
44

0600
117
114
41
46
2,85
2,49
3,54
3,42
20208
19710
28
27
137
40
3,43
23211
37

0650
133
131
45
50
2,96
2,64
3,59
3,49
22972
22509
34
32
156
46
3,42
26704
45

0700
148
145
53
58
2,81
2,50
3,46
3,40
25512
25028
42
41
175
52
3,38
29661
57

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.

GENERAL DATA
Electrical data
Total input current
in cooling mode
Total input current
in heating mode
Maximum current (FLA)
Starting current (LRA)
Compressors

0350

0500

0550

0600

0650

0700

28

38

42

49

55
60

61
67

66
73

72
80

86
95

107
119

(1)

All

24

34

38

44

54

59

64

70

85

106

A
A

40
124

49
146

61
175

74
215

75
216

85
226

94
191

114
228

144
285

147
288

type
n
n
type

2
2

2
2

2
2

2
2

2
2

3
2

4
2

4
2

4
2

4
2

1
2"

1
2"

1
2"

1
2"

1
2"

2
36500
22400
36500

2
36500
22400
36500

3
58000
31900
58000

3
58000
31900
58000

500

500

53
45
85
77

53
45
85
77

Scroll

R410A

(in/out)

type
n

1
2"

1
2"

1
2"

1
2"

All
HA
HE
All

type
n
m3/h
m3/h
m3/h

4
14000
14000

6
20000
20000

8
26000
26000

8
26000
26000

l
kPa

300

300

42
74

42
74

Fans
Air flow rate
cooling mode
Air flow rate heating mode
System integrated hydronic module
Buffer tank
Useful head
Soud data

Power supply

0330

A
A

Exchanger

Sound power

0300

HA
HE

Circuits
Refrigerant
Exchanger system side

Sound pressure

0280

(1)
(1)

Compressors

hydraulic connect. victaulic


Fans standard

0200

HA
HE
HA
HE

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Plate
1
2"

Axial
2
2
37000 36500
21100 21400
37000 36500

300
300
500
500
500
500
For more information, refer to the technical documentation
43
75

43
75

50
50
42
42
82
82
74
74
400V/3N/50Hz

50
42
82
74

51
43
83
75

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

240

Dimensions (mm)
NRK 0200

NRK 0280

NRK 0300-0330

NRK 0350-0500-0550-0600

NRK 0650-0700

A
A

C
B

Mod. NRK
(mm)
(mm)
(mm)
(kg)

A
B
C

Vers.
All
All
All

0200
1606
1100
2700
804

C
B

0280
1606
1100
2700
876

0300
1606
1100
3250
960

0330
1606
1100
3250
967

0350
1875
1100
3330
1118

0500
1875
1100
3330
1264

0550
1875
1100
3330
1325

0600
1875
1100
3330
1367

0650
1875
1100
4330
1562

0700
1875
1100
4330
1597

Cod.: SNRKUY.02/ 1502

Height
Width
Depth
Weight when empty

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

241

MEC-W

Water-cooled packaged air conditioners


With radial fans and capacities from 11 up to 55 kW

R407C

Features
Available in 5 different sizes
All versions are supplied for use with R407C
Metallic protective cabinet with rustproof
polyester paint
Double suction radial fans
Electric motors with belt transmission

Four row evaporator coil with copper tubes Plate-type condenser


and aluminium fins
Water flow control valve driven directly in
Washable air filter
relation to condensing pressure
Room thermostat with one or two contacts
depending on the model
Hermetic compressors

Accessories
BAS: Hot water coil with three rows of alumi- PL: Air distribution plenum comprising delinium finned copper tubes.
very grille with two rows of adjustable slats

and internal lining of sound insulating material.

Compatibility of accessories
Mod.
BAS 30
BAS 50
BAS 75
BAS 100
BAS 150
BAS 200
BAS 300
PL 22
PL 23
PL 26
PL 37
PL 38
PL 39
PL 300

242

307 W

507 W

757 W

1007 W

1507 W

Technical data
Mod. MEC
Cooling capacity
Input power
Water flow rate at 30 C
Pressure drops
Water consumption at 16 C*
Pressure drops*
Heating capacity (accessory BAS)
Pressure drops (accessory BAS)
Coil rows
Nominal air flow rate
e Sound pressure
Motor power

307 W
11
3,05
2350
38
620
3,5
25,28
3,47
4
2040
63
0,375
840
1120
79
104
130
1600
2400
12,2
6
98
48

kW
kW
l/h
kPa
l/h
kPa
kW
kPa
n.
m3/h
dB (A)
kW
g/m (min.)
g/m (max.)
mm (min.)
mm (max.)
mm
m3/h (min.)
m3/h (max.)
A (230 V)
A (400 V)
A (230 V)

Speed
Motor pulley diameter
Fan pulley diameter
Air flow rate
Input current
Peak current

507 W
18
4,45
3740
65
990
6,7
46,61
4,01
4
3400
65,5
0,75
840
1120
79
104
130
2750
4100
15,4
8,9
142
68

757 W
29
7,3
5900
56
1550
5
58,01
3,97
4
5100
72,5
1,125
840
1120
79
104
130
4100
6000
24,2
13,9
168
101

1007 W
35
8,5
7270
65
1910
5,3
78,59
4,59
4
6800
69,5
1,5
620
810
79
104
180
5500
8200
30,8
17,8
157
77

1507 W
55
13,7
11270
53
2970
5
113,68
5,77
4
10200
73,5
1,125
840
1120
79
104
130
8200
12000
46,6
26,9
190
115

Power supply: 3~ 230V 50Hz; 3N~ 400V 50Hz.

Cooling
room air temperature 27 C D.B., 19 C W.B.;
condensing temperature 40 C;
condensing temperature 35 C.

Heating
water inlet temperature 85 C;
air intake temperature 15 C;

e Sound pressure measured in an 85


m3 semi-reverberant test chamber
with reverberation time Tr = 0.5s..

Dimensions (mm)

A
B
C
kg

307 W
1290
900
494
147

507 W
1410
1040
558
184

757 W
1680
1220
648
273

1007 W
1700
1450
723
335

1507 W
1745
1880
753
484
Cod.: SMECUY.03 / 0301

Mod.
Height
Width
Depth
Weight

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Fax 044293577
www.aermec.com

243

CL

Air cooled chiller and heat pump with plug fan


Cooling Capacity from 5,82 to 40,34 kW
Heating capacity from 7,92 to 44,00 kW

025/200

R410A
Aermec
hZKsEd
W>WWZ
d


HEAT PUMP OPTIMISED FOR HEATING:


PRODUCTION OF HOT WATER UP TO 60C
HEATING OPERATION WITH EXTERNAL
TEMPERATURES FROM -15C TO 42C
INTERFACES WITH VARIABLE MULTIFLOW VMF
SYSTEM
EVAPORATING AND CONDENSING CONTROL
STANDARD
INVERTER PLUG FAN

AVAILABLE VERSIONS:
STANDARD
WITH PUMP
WITH PUMP AND BUFFER TANK
DOMESTIC HOT WATER (DHW)
PRODUCTION WITH EXTERNAL
TEMPERATURES FROM -15C TO 42C

Characteristics

Available in 10 sizes
Cooling only and heat pump models "H"
Manufactured with refrigerant R410A
Versions available:
"" Standard
"P" With pump, expansion tank and water filter
"A" With pump, expansion tank, water filter and
buffer tank
All versions are available for the production of
chilled water down to -6C (see unit configurator option)
Compressors isolator and mains isolator standard on all models

Horizontal or vertical air discharge site adjustable for all sizes


Plastic directional air discharge hood for sizes
050 to 090
Galvanised steel directional air discharge hood
for the other sizes
High Efficiency Scroll Compressor
Compressor crank case heater standard
Water filter and flow switch standard on all versions
Plug fans with EC Inverter motors conforming to
regulation EU 327/2011
Through continuous fan speed control permits

operation in cooling mode with external temperatures down to -10C and in heating mode
with external temperatures up to 42C
Electronic controller with start timers and optimisation of defrost cycles
High efficiency plate heat exchanger
Plate heat exchanger anti-freeze electric heater
"KR" standard on heat pump "H" models
Condensate drain tray standard on heat pump
"H" models
Anti-freeze electric heater standard for the buffer tank

Accessories
AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of
the unit to which it is connected, based on a
0-10V MODBUSinput signal. Mandatory accessory: AER485 or MODU-485A
MODU - 485A: RS-485 interface for supervising systems with MODBUS protocol. (accessory
mandatory for the production of domestic hot
water).
DRE: Electronic soft starter. Reduces starting current by about 30%. Factory fitted only.
KR: Plate heat exchanger anti-freeze electric heater
(only available for cooling only versions)
Factory fitted only.
PR3: Simplified remote panel. Permits control of
basic unit functions and alarm notification.
Remote mounted with shielded cable up to 30
m distance.
VT: Anti-vibration mounts.
CLPA: Galvanised steel plenum to be installed on
the condenser coil. Facilitates duct installations.
GPCL: Protective grille. Protects the external
condenser coil from damage.

244

for temperature monitoring.


KR B4/B5/B6: Electric base heater to prevent
the formation of ice (only available for heat - SDHW: Domestic hot water temperature sensor.
pump versions).
Used with the storage tank to control the temperature of water produced.
BSKW: External electric heater kit of various
capacities with single and three phase power AERWEB300: Accessory AERWEB allows remote
supplies:
control of a chiller through a common PC and an
- BS4KW230M (4kW, 230V/1/50Hz)
ethernet connection over a common browser; 4 ver- BS6KW230M (6kW, 230V/1/50Hz)
sions available:
- BS6KW400T (6kW, 400V/3/50Hz)
- AERWEB300-6: Web server to monitor and remote
control max. 6 units in RS485 network;
- BS9KW400T (9kW, 400V/3/50Hz)
- AERWEB300-18: Web server to monitor and
MULTICONTROL: can be used as a remote panel for
a single unit or to simultaneously control several
remote control max. 18 units in RS485 network;
- AERWEB300-6G: Web server to monitor and
chillers or heat pumps (up to 4) installed in the same
remote control max. 6 units in RS485 network with
hydraulic system, fitted with our MODUCONTROL
controller.
integrated GPRS modem;
For complete control the following accessories are
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network
available:
with integrated GPRS modem;
- SPLW: System water temperature sensor. In most
cases the loose supplied sensors for each chiller/heat COMPATIBILITY with the VMF SYSTEM
pump are sufficient. In cases of a common flow/
For more information on the system refer to the
return header this sensor can be used to control the
manual.
common system supply water temperature for the
chillers connected to the header, or it can be used

Unit configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Conguration elds
12

345

10

11

12

13

|
Code

|
|
|
Size

|
Model

|
|
|
Execution

|
Version

|
|
|
Heat recovery

|
Coil

|
|
|
Field of use

|
Evaporator

|
|
|
Power supply

Code:
CL
Size:
025, 030, 040, 050, 070, 080, 090, 100, 150, 200
Model:
- Cooling only
H- Heat pump
Execution
- Standard
L - Low noise
Version:
- Standard
P- With pump
A- With pump and buffer tank
Heat recovery:
- Without heat recovery
D - With desuperheater
(for Cooling only models sizes 050 to 200)

Coil:
- Aluminium
R- Copper
S- Tinned copper
V- Epoxy coated aluminium
Field of use:
- Standard
Z - Low temperature leaving liquid from +4C to 0C
Y -Low temperature leaving liquid from 0C to -6C
Evaporator:
- Standard
C- Condensing unit
Power supply:
- 3N~ 400V 50Hz
M - 1~ 230V 50Hz (only for sizes 025 to 040)
3 - 3~ 230V 50Hz (only for sizes 090 and 200, for other sizes contact the factory)
Heat pump "H" model
- condensing unit "C"
- desuperheater "D"
- low noise "L"

Heat recovery "D"


not possible with:
- thermostatic expansion valve "Z" - "Y"
- condensing unit "C"

WARNING
The integral buffer tank of the CLH unit refers to the
system and not to the production of domestic hot water.

CL

25

"" COOLING ONLY


"H" HEAT PUMP

30

Power supply

40

50
H

70
H

80
H

90
H

100

150

200

(1)

KRB4

All

(1)

KRB5

All

(1)

KRB6

All

BS4KW230M

All

BS6KW230M

All

BS6KW400T

3N~ 400V 50Hz

BS9KW400T

3N~ 400V 50Hz

Std

All

Std

Std

Std

Std

Std

Std

Std

Std

Std

PR3

All

VT

/ H / P / HP
A / HA

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

9
15A

15
15

15
15

15
15

15
15

15
15

15
15

(1)

KR2

AERSET
(2) MODU

- 485A

(3) CLPA

All

All

All

3N~ 400V 50Hz


3 ~ 230V 50Hz

5
5

5
5

(1) GPCL

All

MULTICONTROL

All

SPLW

All

SDHW

All

AERWEB300

All

(4) DRE

Power supply 1~ 230V 50Hz is available only for sizes 025 - 030 - 040
Accessory factory tted only
mandatory for the production of domestic hot water
(3) Not available with accesory GPCL only for sizes 025 to 090
(4)DRE not available for power supply 1~ 230V 50Hz
(1)

(2) Accessory

5 (x2) 5 (x2) 5 (x2) 5 (x2) 5 (x2) 5 (x2)


5 (x2) 5 (x2)

Available accessory

Std

Fitted as standard

Not available

245

Technical data
Only cooling
(1)

Cooling capacity
Total power input
EER (14511:2013)*
EER (14511:2011)
ESEER
Water flow rate
Pressure drops
Useful head pump
Only cooling low noise

(1)

Cooling capacity
Total power input
EER (14511:2013)*
EER (14511:2011)
ESEER
Water flow rate
Pressure drops
Useful head pump

P|A

P|A

P|A

P|A

P|A
alls

P|A

kW
kW
kW
kW
W/W
W/W
W/W
W/W

P|A

P|A

P|A

P|A

P|A
alls

P|A

kW
kW
kW
kW
W/W
W/W
W/W
W/W

l/h
kPa
kPa

l/h
kPa
kPa

025
5.82
5.87
2.23
2.27
2.61
2.59
2.79
2.77
2.87
2.85
1009
19.0
58.0
025
5.65
5.70
2.24
2.28
2.52
2.50
2.65
2.63
2.67
2.65
979
18.0
59.0

030
7.11
7.18
2.70
2.72
2.63
2.64
2.79
2.8
2.90
2.91
1234
26.0
49.0
030
6.90
6.97
2.71
2.73
2.55
2.56
2.66
2.66
2.70
2.71
1197
25.0
50.0

040
8.80
8.89
3.62
3.61
2.43
2.46
2.54
2.56
2.67
2.70
1525
25.0
50.0
040
8.53
8.62
3.62
3.62
2.35
2.38
2.43
2.46
2.50
2.52
1479
24.0
52.0

050
12.65
12.80
4.37
4.35
2.89
2.94
3.13
3.18
3.18
3.23
2191
27.0
79.0
050
12.14
12.29
4.42
4.41
2.75
2.78
2.88
2.92
2.91
2.95
2104
25.0
82.0

070
16.28
16.47
5.58
5.52
2.92
2.98
3.11
3.17
3.21
3.28
2820
29.0
74.0
070
15.63
15.82
5.62
5.58
2.78
2.84
2.89
2.94
2.95
3.01
2707
27.0
77.0

080
18.30
18.51
6.78
6.71
2.70
2.76
2.84
2.9
2.97
3.04
3170
30.0
73.0
080
17.57
17.78
6.83
6.77
2.57
2.63
2.68
2.74
2.73
2.79
3043
28.0
75.0

090
20.14
20.37
6.93
6.84
2.91
2.98
3.08
3.16
3.20
3.28
3487
29.0
71.0
090
18.54
18.75
7.52
7.45
2.47
2.52
2.55
2.61
2.61
2.67
3208
25.0
77.0

100
26.16
26.71
8.99
9.03
2.91
2.96
3.09
2.85
4.21
4.28
4538
45.0
82.0
100
24.09
24.60
9.77
9.84
2.47
2.50
2.55
2.58
3.54
3.59
4175
38.0
91.0

150
32.86
33.68
11.51
11.69
2.85
2.88
3.05
2.91
4.13
4.17
5701
53.0
131.0
150
31.56
32.35
11.60
11.81
2.72
2.74
2.85
2.87
3.91
3.94
5473
49.0
137.0

200
40.34
41.33
14.57
14.67
2.77
2.82
2.92
2.74
4.01
4.08
7009
72.0
122.0
200
37.27
38.20
14.63
14.78
2.55
2.58
2.64
2.68
3.66
3.71
6472
66.0
129.0

080H
15.49
15.67
5.73
5.68
2.70
2.75
2.97
3.03
2678
25.89
81.0
18.61
18.39
5.60
5.52
3.32
3.33
3.55
3.56
3181
32.2
71.0

090H
18.92
19.14
6.91
6.84
2.74
2.80
3.01
3.08
3275
26.0
75.0
21.06
20.81
6.71
6.62
3.14
3.14
3.33
3.35
3597
34.0
70.0

100H
23.82
24.34
8.36
8.43
2.85
2.89
4.12
4.18
4126
34.0
99.0
27.98
27.41
8.30
8.35
3.36
3.28
3.59
3.50
4772
49.0
81.0

150H
31.21
31.94
11.17
11.43
2.79
2.79
4.04
4.04
5394
22.0
157.0
34.92
34.14
10.86
11.11
3.21
3.07
3.45
3.29
5971
30.0
147.0

200H
37.43
38.31
14.67
14.93
2.55
2.57
3.70
3.71
6484
43.0
144.0
44.0
43.84
14.75
14.98
2.97
2.87
3.18
3.07
7346
42.0
130.0

* The legislation 14511: 2013 from the previous 14511: 2011 provides a different contribution of the fan
Cooling: (EN14511:2013) - All data to nominal available fan static pressure
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C (1) 230V/1/50Hz = 400V/3N/50Hz

Heat pump
(1)

Cooling capacity
Total power input
EER
ESEER
Water flow rate
Pressure drops
Useful head pump

(1)

Heating capacity
Total power input
COP (14511:2013)*
COP (14511:2011)
Water flow rate
Pressure drops
Useful head pump

H
kW
HP/HA kW
H
kW
HP/HA kW
H
W/W
HP/HA W/W
H
HP/HA
l/h
H
kPa
HP/HA kPa
H
kW
HP/HA kW
H
kW
HP/HA kW
H
W/W
HP/HA W/W
H
W/W
HP/HA W/W
l/h
H
kPa
HP/HA kPa

025H
6.39
6.44
2.69
2.72
2.37
2.37
2.61
2.61
1105
13.0
64.0
7.92
7.85
2.39
2.40
3.30
3.27
3.53
3.48
1406
19.0
57.0

030H
8.35
8.42
3.13
3.14
2.67
2.69
2.93
2.95
1442
12.0
63.0
9.79
9.7
3.01
3.01
3.25
3.23
3.42
3.40
1740
16.0
58.0

040H
10.34
10.44
3.89
3.88
2.66
2.69
2.92
2.96
1787
13.0
60.0
12.52
12.39
3.79
3.76
3.30
3.30
3.63
3.62
2113
18.0
53.0

050H
11.90
12.03
4.27
4.27
2.79
2.82
3.07
3.10
2055
11.0
98.0
14.47
14.3
4.22
4.20
3.42
3.41
3.72
3.71
2476
17.0
93.0

070H
13.96
14.12
4.93
4.91
2.83
2.87
3.11
3.16
2413
15.0
93.0
15.95
15.76
4.85
4.81
3.28
3.28
3.53
3.52
2727
21.0
88.0

* The legislation 14511: 2013 from the previous 14511: 2011 provides a different contribution of the fan
Cooling: (EN14511:2013) - All data to nominal available fan static pressure
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating: (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
(1) 230V/1/50Hz = 400V/3N/50Hz

Electrical data
Total input current
colling mode
Total input current
colling mode version "H"
Total input current
heating mode version "H"
maximum current (FLA)
only cooling version
Starting current (LRA)
only cooling version

246

(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N
230V/1
400V/3N

A
A
A
A
A
A
A
A
A
A

025

030

040

050

070

080

090

100

150

200

10,14
4,80
12,70
5,50
11,80
5,50
21,6
11,1
66,6
37,6

12,99
5,10
15,40
6,30
14,30
6,20
24,6
11,6
87,6
40,6

16,91
7,50
16,00
6,70
15,66
6,50
24,7
12,6
117,6
71,6

8,53
7,68
7,64
13,68
77,18

10,23
8,38
8,18
15,38
77,18

12,03
9,77
9,34
16,98
77,18

12,89
13,42
12,71
20,38
105,18

16,72
14,34
14,34
27,36
90,86

19,76
21,25
19,45
30,76
92,56

25,36
26,61
26,49
40,76
125,56

Technical data
maximum current (FLA)
version H
Starting current (LRA)
version H
Compressors

(2)
(2)
(2)
(2)

230V/1
400V/3N
230V/1
400V/3N

type
n
n
type

Compressors
Circuit
Refrigerant
System side exchanger
Exchanger
Hydraulic connection
fans

Sound power

030
23,70
11,96
95,51
44,60

040
24,00
11,92
96,14
57,18

050
13,50
64,18

070
14,68
74,18

1
1

1
1

1
1

1
1

1
1

080
15,15
94,18

090
20,38
105,18

100
27,00
77,68

150
30,30
109,33

200
40,76
125,56

1
1

1
1

2
1

2
1

2
1

scroll

R410A

type
n

Plate
1
1"

1
1"

1
1"

1
1"

1
1"

1
1"

1
1"

1
1"

1
1"

Pa

1
4000
4000
3000
50

1
4000
4000
3000
50

1
4000
6500
3000
50

1
6500
6500
4000
80

Plug fan
1
1
6500
6500
6500
6500
4000
5000
80
80

1
7500
7500
5000
80

2
10000
10000
6000
80

2
12000
12000
8500
100

2
12000
16000
8500
100

H
L

H
L

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)

46,3
46,3
38,6
78,3
78,3
70,6

46,3
46,3
38,6
78,3
78,3
70,6

46,3
41,0
38,6
78,3
73,0
70,6

41,0
41,0
36,9
73,0
73,0
68,9

41,0
41,0
36,9
73,0
73,0
68,9

43,7
43,7
36,9
75,7
75,7
68,9

42,4
42,4
33,6
74,4
74,4
65,6

46,7
46,7
39,7
78,7
78,7
71,7

46,7
48,4
39,7
78,7
80,4
71,7

H
L

H
L

dB(A)
46,3
46,3
46,3
45,9
45,9
45,9
48,9
46,5
51,9
51,9
dB(A)
46,3
46,3
45,9
45,9
45,9
45,9
48,9
46,5
51,9
53,6
dB(A)
38,7
38,7
38,7
35,8
35,8
35,8
35,8
31,6
41,1
41,1
dB(A)
78,3
78,3
78,3
77,9
77,9
77,9
80,9
78,0
83,4
83,4
77,9
77,9
77,9
80,9
78,0
83,4
85,1
dB(A)
78,3
78,3
77,9
dB(A)
70,7
70,7
70,7
67,8
67,8
67,8
67,8
63,1
72,6
72,6
V/ph/Hz 230V/1 230V/1 230V/1
V/ph/Hz 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N

(in/out)

H
L

type
n
m3/h

Nominal high static pressure


Sound data
chiller
Sound pressure

025
18,80
11,01
86,10
44,60

1
1"

Fans (Inverter)
Air flow rate

A
A
A
A

41,0
41,0
36,9
73,0
73,0
68,9

Delivery
Sound pressure
Sound power
Power supply

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
(2) Unit in standard configuration/execution without hydroni kit
Nota: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensional data (mm)


DIMENSIONS - WEIGHTS without packaging - "" COOLING ONLY / "L" LOW NOISE
Version Units 025
030
040
050
070
080
Height (A)
All
mm 1028 1281 1281 1281 1281 1281

P
mm
1005
1006
1006
1160
1160
1160
Width (B)
A
mm 1366 1458 1458 1610 1610 1610
Depth (C)
All
mm
702
754
754
798
798
798

kg
127
160
160
208
210
210
Weight empty
P
kg
133
166
166
217
225
225
A
kg
157
201
201
252
260
260

090
1281
1160
1610
798
212
221
256

100
1674
1897
1897
801
469
482
532

150
1674
1897
1897
801
471
487
537

200
1674
1897
1897
801
475
492
542

DIMENSIONS - WEIGHTS without packaging - "H" HEAT PUMP


Version Units 025
030
040
Height (A)
Tutte
mm 1028 1028 1281
H - HP mm 1005 1005 1160
Width (B)
HA
mm 1366 1366 1610
Depth (C)
Tutte
mm
702
702
798
H
kg
142
142
229
Weight empty
HP
kg
148
148
239
HA
kg
172
172
274

090
1281
1160
1610
798
234
243
279

100
1674
1897
1897
801
504
517
567

150
1674
1897
1897
801
527
543
593

200
1674
1897
1897
801
515
531
581

050
1281
1160
1610
798
229
239
274

Discharge hood possible configurations (site modified)

080
1281
1160
1610
798
240
250
284

C
A
B
A

CL100-200

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

Cod.: SCLUY.04 / 1502

CL025-090

070
1281
1160
1610
798
240
250
284

247

NRC

Air cooled chillers, and condensing units with centrifugal fans


Capacities from 46 to 264 kW

R407C
Aermec participates in the
EUROVENT programme:
LCP The products involved can be
found at the website www.euroventcertification.com

STANDARD VERSION
OPTION FOR PUMP

OPTION FOR PUMP AND


BUFFER TANK

Features
All versions manufactured with refrigerant
R407C
Options for partial or total heat recovery
4 versions available:
- With loose supplied water filter and differential pressure switch
- With pump only
- With low head pump assembly, 500 litre
buffer tank (700 litres for sizes 800 to 1000)
with 300 W anti-freeze heater (2 x 300 W for
sizes 750 to 1000), water filter fitted, and
flow switch
- With high head pump assembly, 500 litre
buffer tank (700 litres for sizes 800 to 1000)
with 300 W anti-freeze heater (2 x 300 W for
sizes 750 to 1000), water filter fitted, and
flow switch

Cooling only version can be requested for


low leaving liquid temperatures 4 C down to

-6 C. This option must be specified at the


time of order
All the versions can be requested with high
static pressure fans which allows nominal air
flow rates with higher static pressure installations. This option must be specified at time of
order. Please refer to the technical manuals
for technical data
The versions with pump and/or buffer tank
are also fitted with automatic air vent valve,
filling point, expansion tank and water pressure relief valve
High efficiency scroll compressors with low
power input
Modulating microprocessor control system
Functional parameters can be displayed in 4
languages
Simplified remote control panel. Provides
access to all the unit basic control functions
and alarm notification

High efficiency plate heat exchangers


Evaporator trace heating
Compressor crank case heater
Low pressure transducer (standard on heat
pump models)
High pressure transducer (standard on heat
pump models and cooling only sizes 500 to
1000)
Air discharge: top discharge for sizes 275 to
550 and front discharge for sizes 600 to 1000
(with top discharge on request)
Centrifugal fans
Compact size
Metallic protective cabinet with anti-corrosion polyester paint

Accessories
AER485: RS-485 interface for supervision sys- PGS: Daily/Weekly Programmer. Allows two
tems with MODBUS protocol.
daily time-clock programmes (two switch on/
off cycles) and different programmes for each
AERSET
day of the week.
The AERSET accessory allows the automatic
compensation of the operating setpoint of the unit RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
to which it is connected, based on a 0-10V MODreduction of input current. Must be requested
BUS input signal. Mandatory accessory: AER485
at time of order and is available factory fitted
or MODU-485A
only.
AVX: Spring anti-vibration mounts. Select the
AERWEB300: The AERWEB option allows remote
AVX model by using the compatibility table.
control of a chiller through a standard PC and an
DR: Low temperature device, consisting of a
ethernet connection with a standard browser; 4
damper for installation on the fan outlet, moduversions available:
lates air flow to the condenser based on the
AERWEB300-6: Web server to monitor and remote
pressure transducer value. The DR 202 - 402
control maximum 6 units on RS485 network;
accessories also include the TP2 high pressure
transducers. Accessory obligatory in D versions.
AERWEB300-18: Web server to monitor and
DRE: Current soft starter device (about 30%
remote control maximum 18 units on RS485 netreduction for single-circuit-units, 26% for
work;
two-circuit-units, 22% for three-circuit-units).
AERWEB300-6G: Web server to monitor and
Only available for 400V-3-phase power supremote control maximum 6 units on RS485 netply. Factory fitted only
work with integrated GPRS modem;

248

AERWEB300-18G: Web server to monitor and


remote control maximum 18 units on RS485 network with integrated GPRS modem.
TP 1: Low pressure transducer, providing display of operating pressure (one per circuit).
Standard on heat pump models.
TP 2: High pressure transducer, providing display on the microprocessor controller of
working pressure (one per circuit). Standard
on heat pump models and cooling only sizes
500 to 1000.
VT: Anti-vibration mounts, set of four mounts
to be installed under the unit base.
DUALCHILLER: Simplified control system to
switch on/off and control two chillers in a single system (using Aermec GR3 command), as
if they were a single unit.
MULTICHILLER: Control system for multiple
parallel installed constant flow chillers providing individual chiller on/off and control
capability.

Accessory compatibility
Mod.
AER485
AERSET
DUALCHILLER
MULTICHILLER
AVX
DR 202
DR 402

275

300

325

350

500

550

600
650
700
750
800
900
1000

401/402* 401/402* 402/403* 402/403* 404/406* 404/406* 405/407*

DR 600

DR 800
DRE 275
DRE 300

(x2)

(x4)

(x2)

64

(x2)

64

(x2)

(x2)

74

(x2)

DRE 325

DRE 10

(x2)

(x2)

DRE 15

(x2)

(x2)

(x4)

(x4)

DRE 25
DRE 30
PGS
RIF
AERWEB300
TP 1
TP 2

62

(x2)
(x2)

62

(x2)
(x2)

62

(x2)
(x2)

VT 14*
VT 16*

82

(x2)
(x2)

63

(x2)

63

(x2)

VT 17
VT 2

64

(x2)

64

(x2)

64

(x2)

(x2)
(x4)

84

(x2)

DR = Accessory obligatory for D versions.


* = To be used in versions with buffer tank.
N.B. = number in brackets indicates required quantity.

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system
requirements.
Code:
NRC
Size:
0275, 0300, 0325, 0350, 0500, 0550
0600, 0650, 0700, 0750, 0800, 0900, 1000
Field of use:
- Standard with leaving water above +4 C
Y - Low temperature with leaving liquid down to -6 C
Model:
- Cooling only
Heat recovery:
- Without heat recovery
D - With desuperheaters (partial heat recovery)
T - With total heat recovery
Version:
- Standard
L - Low noise
Coil:
- Aluminium
R - Copper
S - Tinned copper
V - Coated aluminium
Evaporator:
- To PED regulations
G - To TV-D regulations (Germany)
C - Condensing unit (without evaporator)
Power supply:
- 400V 3~ 50Hz* with circuit breakers
4 - 230V 3~ 50Hz with circuit breakers
9 - 500V 3~ 50Hz with circuit breakers

Integrated hydronic module:


00 - without pump or buffer tank
01 - single low head pump and buffer tank
02 - single and standby low head pump and buffer tank
03 - single high head pump and buffer tank
04 - single and standby high head pump and buffer tank
05 - single low head pump and buffer tank (with holes for immersion
heaters)
06 - single and standby low head pump and buffer tank (with holes
for immersion heaters)
07 - single high head pump and buffer tank (with holes for immersion
heaters)
08 - single and standby high head pump and buffer tank (with holes
for immersion heaters)
P1 - single low head pump without buffer tank
P2 - single and standby low head pump without buffer tank
P3 - single high head pump without buffer tank
P4 - single and standby high head pump without buffer tank

Attention:
standard options are shown by the symbol
the following options are not available for heat pump models: Y, T, L and C
* (400V 3N~ 50Hz sizes 275,300, 325, 350, 500, 550, 600, 650, 700, 750 / 400V 3~ 50Hz 800, 900, 1000)

249

Technical Data
Mod. only cooling
Cooling capacity
Input power
EER
Water flow rate
Total pressure drops

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

0275
50.70
45.76
22.30
22.94
2.27
1.99
8759
7900
37
30

0300
58.70
53.75
26.40
26.55
2.22
2.02
10133
9274
32
27

0325
66.68
61.72
29.72
29.98
2.24
2.06
11506
10648
31
27

0350
75.57
69.63
32.73
33.47
2.31
2.08
13052
12022
43
36

0500
88.64
80.70
37.96
40.30
2.34
2.00
15285
13911
27
23

0550
96.67
88.72
40.73
43.28
2.37
2.05
16659
15285
22
19

0600
119.5
109.6
52.4
47.9
2.28
2.29
20609
18891
32
27

0650
135.5
125.5
58.4
54.4
2.32
2.31
23356
21639
28
24

0700
155.3
141.4
66.1
62.5
2.35
2.26
26791
24387
36
30

0750
183.4
167.5
77.5
72.9
2.36
2.30
31600
28852
27
23

0800
213.2
193.3
90.7
83.6
2.35
2.31
36752
33317
35
29

0900
237.2
215.3
100.7
94.6
2.36
2.28
40874
37095
30
25

1000
263.2
237.3
113.3
105.1
2.32
2.26
45339
40874
30
25

0600
0650
93,4 101,5
82,8
91,9
131
143
207
215
205
212
Scroll
3
4
4
2
2
2
R407C
Plates
1
1
1
Centrifugal
2
3
3
27000 45000 45000
19000 31500 31500
0

0700
117
107,4
164
267
266

0750
134,5
122,8
190
318
315

0800
153,7
138,1
225
337
334

0900
171,7
155,8
245
404
401

1000
193,2
173,4
277
424
419

4
2

4
2

4
2

4
2

4
2

3
50000
35000

3
50000
35000

4
60000
42000

4
68000
47600

4
68000
47600

91
87
59
55

91
87
59
55

92
88
60
56

92
88
60
57

92
88
60
57

Cooling: (14511:2013) - All the data refers to the nominal value of the useful static pressure
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

General data

0275
(1)
A
40,3
Total Input current
(1) L
A
40,5
Maximum current (FLA) (1) All
A
54
(1)
A
153
Peak current (LRA)
(1) L
A
152
Compressors
type
no. of compressors
n
2
no. of circuits
n
2
Refrigerant
type
System side heat exchanger
type
no. of heat exchangers
n
1
Centrifugal fans
type
no. of fans
n
2
m3/h

16000
Air flow rate
m3/h
L
11000
Useful static pressure
Pa
Sound data
dB(A)
85

Sound power
dB(A)
L
81
dB(A)
53

Sound Pressure
dB(A)
L
49
V/ph/Hz
Power supply

0300
46,5
45,8
63
161
158

0325
51,3
50,7
71
165
163

0350
57,5
57,7
80
208
206

0500
68,1
68,7
93
219
217

2
2

2
2

2
2

3
2

2
22000
15500

2
22000
15500

2
26000
18000

2
27000
19000

85
81
53
49

85
82
54
50

88
84
56
52

88
84
56
52

0550
72,1
73,3
99
223
221

88
84
56
52

90
86
58
54

90
86
58
54

400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound power (calculated when cold)
Aermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested by Eurovent certification.
Sound Pressure
Sound pressure measured in free field, 10 m away from the unit external surface (in compliance with UNI EN ISO 3744).
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

250

Dimensions (mm)

NRC 275 - 550 without buffer tank

NRC 275 - 550 with buffer tank

NRC 600 - 1000 without buffer tank

NRC 600 - 1000 with buffer tank

275
1763
2100
950
629

300
1793
2100
950
665

325
1793
2100
950
699

350
1763
2450
950
777

500
1963
2450
950
904

550
1963
2450
950
919

600
2288
3750
1100
1481

650
2288
3750
1100
1498

700
2288
4550
1100
1737

750
2288
4550
1100
1918

800
2295
4950
1300
2670

900
2295
4950
1300
2700

1000
2295
4950
1300
2960

Model NRC P1/P4 (with pumping assembly)


275
A
mm
1763
B
mm
2100
C
mm
950
Weight
(kg)
663

300
1793
2100
950
699

325
1793
2100
950
733

350
1763
2450
950
811

500
1963
2450
950
938

550
1963
2450
950
953

600
2288
3750
1100
1659

650
2288
3750
1100
1676

700
2288
4550
1100
1914

750
2288
4550
1100
2096

800
2295
4950
1300
2870

900
2295
4950
1300
2900

1000
2295
4950
1300
3160

Mod. NRC 01/08 (with buffer tank unit and pump)


275
300
A
mm
1763 1793
B
mm
2950 2950
C
mm
950
950
Weight
(kg)
827
891

325
1793
2950
950
901

350
1763
3300
950
996

500
1963
3300
950
1121

550
1963
3300
950
1138

600
2288
4550
1100
1743

650
2288
4550
1100
1760

700
2288
5350
1100
1998

750
2288
5350
1100
2180

800
2295
5750
1300
3070

900
2295
5750
1300
3100

1000
2295
5750
1300
3350

A
B
C
Weight

mm
mm
mm
(kg)

Note: the weights given for the versions with buffer tank refer to the empty weight.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

251

Cod.: SNRCUY.15 / 1502

Model. NRC 00 (without buffer tank)

NEW

NLC
0280/1250

Reversible Air/Water heat pump for indoor installation


Scroll compressors, plate exchangers and plug-fans
Cooling capacity from 52316kW
Heating capacity from 56349kW

heat pump

R410A
Aermec
is participating in the
EUROVENT Program : LCP
The involved products can be found in the website
www.eurovent-certification.com

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


COOLING CIRCUIT WITH CASING
COMPLETE AIR FLOW VERSATILITY
HIGH EFFICIENCY PLUG-FANS
NIGHT MODE

Features
The range includes units with two single circuit compressors and units with four compressors divided into two independent circuits.
The possibility of using the electronic thermostatic valve brings significant benefits, especially when the heat pump is working at partial loads to the benefit of the unit's energy
efficiency.
Electric resistance for the evaporator as standard.
Condensate drip tray as standard.
Possibility of integrated hydronic kit that
encloses the main hydraulic components; it is
available in different configurations with one
Versions
or two pumps, with different static pressures
NLC_HA High efficiency
available, with or without storage tank.
NLC_HE Silenced high efficiency
The units are equipped with plug-fans and
inverter motors coupled directly with the fan,
Operating range: Work up to 44C of outdoor
with the electronic condensation control as
air temperature at full load, depending on size
standard, which adjusts the air flow accordand version. For further details refer to the selecing to the actual system requirements, with
tion software/technical documentation.
benefits in terms of consumption and noise
The NLC pumps are reversible heat pumps,
designed and manufactured for the production
of chilled / heated water in residential / commercial buildings.
The units are equipped with high efficiency
scroll compressors, plug-fans, external copper
coils with aluminium louvers, plate heat
exchangers on the system side. In the units (with
desuperheater), in the cooling mode, there is
also the possibility of producing hot water for
free. The base, the structure and the panels are
made of galvanised steel treated with rustproof
polyester paint.

reduction. In addition, compared to conventional centrifugal fans, they do not feature


belt and pulley transmission, resulting in easy
flow adjustment, compactness, versatility,
easy maintenance and no vibrations.
Horizontal or vertical air flow.
Microprocessor adjustment, with keyboard
and LCD display, for easy consultation and
intervention on the unit via a menu available
in several languages.
Adjustment includes complete management
of the alarms and their log.
The presence of a programmable timer allows
setting time bands of operation and a possible
second set-point.
The temperature control takes place with the
integral proportional logic, based on the
water output temperature.
Night Mode: it is possible to set a silenced
operation profile.
Perfect for night operation, since it guarantees
greater acoustic comfort in the evenings, and
a high efficiency in the time of greater load.

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol.
AERWEB300: the AERWEB device allows the
remote control of a chiller by means of a common PC through Ethernet connection, via a
common browser; 4 models available:
AERWEB300-6: Web server for monitoring and
controlling maximum 6 RS485 network devices;
AERWEB300-18: Web server for monitoring and
controlling maximum 18 RS485 network devices;
AERWEB300-6G: Web server for monitoring
and controlling maximum 6 RS485 network
devices with integrated GPRS modem;
AERWEB300-18G: Web server for monitoring

252

and controlling maximum 18 RS485 network


devices with integrated GPRS modem;
PGD1: Allows you to control the chiller at a distance.
MULTICHILLER_PCO: Control, switch-on and
switch-off system of the single chillers where
multiple units are installed in parallel, always
ensuring constant flow rate to the evaporators.
AVX: Spring anti-vibration mounts.
FLG: Flanges for ducts.
FL: Flow switch.
FILW: Water filter
Attention, the flow switch and the water filter
must be mounted; failure to do so will void the
warranty.

Accessories mounted in the factory;


DRE: Plate peak current reduction electronic
device.
RIFNLC: Current power factor correction.
Connected in parallel to the motor, it allows a
reduction of the input current (approx. 10%).
KRB: Resistance for condensate drip tray.
KRQ: Anti-condensate electric board resistance.
KRA: Storage tank antifreeze resistance.
COMPATIBILITY with the VMF SYSTEM
For further information on system, refer to specific documentation.

Accessories compatibility
Mod. NLC_H
.
AER485P1
AERWEB300
PGD1
MULTICHILLER_PCO
FL
FILW
FLG
AVX

0280

0300

0330

0350

0550

0600

0650

0675

0700

0750

0800

0900

1000

1100

1250

DN50

DN50

DN50

DN50

DN50

DN50

DN50

DN50

DN60

DN60

DN80

DN80

DN80

DN80

DN80

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

300
2
21

KRA1

350
3
21

KRA1

552
1
22

KRA2

602
1
22

KRA2

652
1
22

KRA2

675
4
22

KRA2

602 (x2)
1 (x2)
22 (x2)

KRA2

652 (x2)
1 (x2)
22 (x2)

KRA2

675 (x2)
4 (x2)
22 (x2)

KRA2

1250
3 (x2)
22 (x2)

KRA2

Accessories mounted in the factory;


275
275
DRE
RIFNLC
1
1
KRB
21
21
KRQ

KRA
KRA1
KRA1

350 (x2) 552 (x2) 552 (x2)


3 (x2)
3+2
1 (x2)
21 (x2) 21 + 22 22 (x2)

KRA2
KRA2
KRA2

* Accessories to be defined for compatibility

Choosing the unit


By appropriately combining the variety of options available, every model can be configured in order to meet all specific system requirements.
Field
1,2,3
4,5,6,7
8

X
9
H
10

D
11
A
E
12

R
S
V
13
J
14

1
15-16
00
01
02
03
04
05
06
07
08
P1
P2
P3
P4
P5
P6
P7
P8

Description
NLC
Sizes
0280-0300-0330-0350-0550-0600-0650-0675-0700-0750-0800-0900-1000-1100-1250
Scope of application
Standard (water produced up to +4C)
Electronic thermostatic valve (water produced up to +4 C) (1)
Model
Heat Pump
Heat recovery
Without heat recovery
With desuperheater (2)
Version
High efficiency
Silenced high efficiency
Coils
Aluminium
Copper - Copper
Copper - Thinned
Painted aluminium
Fan
EC inverter
Power supply
400V/3/50Hz with magnet circuit breakers
220V/3/50Hz with magnet circuit breakers
Integrated hydronic kit (3)
Without hydronic kit
Storage tank and single low static pressure pump
Storage tank, single low static pressure pump and reserve pump
Storage tank and single high static pressure pump
Storage tank, single high static pressure pump and reserve pump
Storage tank and single low static pressure pump
Storage tank, single low static pressure inverter pump and reserve inverter pump
Storage tank and single high static pressure inverter pump
Storage tank, single high static pressure inverter pump and reserve inverter pump
Single low static pressure pump
Single low static pressure pump and reserve pump
Single high static pressure pump
Single high static pressure pump and reserve inverter pump
Single low static pressure inverter pump
Single low static pressure inverter pump and reserve inverter pump
Single high static pressure inverter pump
Single high static pressure inverter pump and reserve inverter pump

(1) Contact the head office for lower temperatures


(2) The desuperheater may only be used for the cooling mode
(3) The speed of the inverter pump must be set upon commissioning, according to the useful static pressure required; once it has been set, the pump will work at a constant flow rate

253

Technical data
Mod NLC_H
Cooling capacity
Input power
EER (14511:2013)*
EER (14511:2011)
Water flow rate
Total pressure drops
Heating capacity
Input power
COP (14511:2013)*
COP (14511:2011)
Water flow rate
Total pressure drops

HA
HE
HA
HE
HA
HE
HA
HE
HA
HE
HA
HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE

kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
W/W
W/W
l/h
kPa

0280 0300 0330 0350 0550


54.3 60.3 66.6 78.4 102
52.0 58.1 63.4 74.8 97.6
20.4 22.9 24.8 29.0 38.4
20.7 23.3 25.8 29.8 40.6
2.66 2.63 2.68 2.70 2.67
2.51 2.49 2.45 2.51 2.41
2.90 2.87 2.89 2.89 2.89
2.67 2.65 2.58 2.64 2.54
9378 10407 11493 13550 17657
8977 10032 10946 12919 16848
21
25
23
30
24
20
24
20
27
20
56.5 63.7 70.9 82.8 110
19.5 22.3 24.4 28.3 37.6
2.90 2.85 2.91 2.93 2.92
3.16 3.12 3.14 3.15 3.17
9596 10814 12034 14050 18689
22
27
25
32
27

0600
115
110
44.0
46.6
2.61
2.37
2.83
2.50
19877
19061
29
25
123
42.2
2.91
3.16
20833
32

0650
126
118
47.5
49.6
2.65
2.39
2.84
2.50
21725
20424
35
29
137
47.0
2.92
3.13
23310
40

0675
143
137
55.2
57.1
2.59
2.39
2.77
2.51
24718
23568
35
30
157
54.3
2.89
3.09
26639
41

0700
158
150
58.1
59.4
2.72
2.52
2.90
2.65
27243
25875
26
24
169
56.6
2.98
3.19
28671
29

0750
181
172
67.1
67.9
2.69
2.53
2.89
2.67
31193
29653
25
25
194
66.0
2.94
3.16
32954
28

0800
202
192
75.8
80.5
2.66
2.39
2.88
2.52
34790
33199
34
33
219
74.7
2.93
3.18
37171
38

0900
232
223
88.3
91.1
2.63
2.45
2.84
2.59
40045
38543
34
35
245
84.2
2.91
3.16
41666
37

1000
252
242
94.7
98.0
2.66
2.47
2.85
2.59
43528
41708
36
38
274
92.6
2.96
3.18
46557
41

1100
286
273
110.2
113.6
2.60
2.40
2.78
2.53
49436
47144
38
42
313
106.6
2.94
3.15
53208
43

1250
316
304
128.8
129.2
2.45
2.35
2.60
2.47
54496
52532
44
53
349
119.5
2.92
3.11
59279
52

* Standard 14511:2013, compared to the previous standard 14511:2011, requires a different contribution of the fan
Cooling: (14511:2013) - All the data refers to the nominal value of the useful static pressure
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Heating: (14511:2013) - All the data refers to the nominal value of the useful static pressure
Condenser water temperature (in/out) 40C/45C; External air temperature 7C d.b./6C w.b.

General data
Input current
total (when cold)

(1) HA
(1) HE
HA
(1)
HE

Total input current


(when hot)
Compressors
no. of compressors
no. of circuits
Refrigerant
System side heat exchanger
no. of heat exchangers
Inverter fans
no. of fans
Air flow rate

Sound Pressure
Power supply

0280
36
36

0300
41
40

0330
45
45

0350
56
55

0550
68
69

0600
77
77

0650
81
83

0675
96
95

0700
112
111

0750 0800 0900 1000 1100 1250


121
136
155
162
192
219
121
139
153
166
191
218

36

40

44

54

65

74

78

91

105

114

type
n
n
type
type
n
type
n
HA
HE

Useful static pressure


Sound data
Sound power

A
A

m3/h
m3/h

Pa
HA
HE
HA
HE

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

129

153

179

199

Scroll
2
4
4
4
4
4
4
4
1
2
2
2
2
2
2
2
R410A
Plates
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Plug-fan
2
2
2
2
4
4
4
4
4
6
8
8
8
8
8
23000 26500 25000 27500 42000 47000 44000 50000 53000 64500 84000 94000 88400 102000 102000
17000 19800 17200 20600 30000 35000 31400 38200 41000 48900 60000 70800 64000 77600 88000
120
2
1

2
1

2
1

2
1

2
1

2
1

2
1

84.1
77.3
52.4
45.5

87.9
80.5
56.1
48.8

86.3
77.6
54.6
45.8

88.9
81.5
57.1
49.7

85.2
78.5
53.3
46.6

87.9
81.3
56.0
49.4

86.4
79.4
54.5
47.5

89.5
83.2
57.6
51.3

91.9
84.5
59.9
52.5

86.7
79.4
54.5
47.3

88.2
81.5
55.9
49.2

400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound power (calculated when cold)
Aermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested by Eurovent certification.
Sound Pressure
Sound pressure measured in free field, 10 m away from the unit external surface (in compliance with UNI EN ISO 3744).
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

254

145

90.9
84.3
58.6
52.0

89.4
82.4
57.1
50.1

92.5
86.2
60.2
53.9

92.5
86.2
60.2
53.9

Dimensions

The drawings show some of the steelwork, there is more information available in the technical documentation

Mod. NLC_H

Width

Depth

00
P1P8
0108

mm
mm
mm
mm
mm

0280
2154
1750
2500
3400
950

0300
2154
1750
2500
3400
950

0330
2154
1750
2500
3400
950

0350
2154
1750
2500
3400
950

0550
2196
3150
3150
4150
1100

0600
2196
3150
3150
4150
1100

0650
2196
3150
3150
4150
1100

0675
2196
3150
3150
4150
1100

0700
2196
3500
4250
5250
1100

0750
2196
4900
4900
5900
1100

0800
2196
6300
6300
7300
1100

0900
2196
6300
6300
7300
1100

1000
2196
6300
6300
7300
1100

1100
2196
6300
6300
7300
1100

1250
2196
6300
6300
7300
1100

Code: SNLCH0280_1250UY.00 / 1503

Height

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

255

NSM

Air/Water chillers for outdoor installation


Screw compressors, shell and tube heat exchangers and axial fans
Cooling capacity 3022100kW

1402/9603
cooling only

R134a
Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


MICROCHANNEL COIL
QUICK AND EASY INSTALLATION
NIGHT MODE

Characteristics
Outdoor chillers for the production of chilled
water with high-efficiency screw compressors,
with cooling capacity adjustment via continuous modulation. Axial fans, microchannel
external coils, plant side shell and tube heat
exchanger. In the units (with desuperheater or
total recovery) there is also the possibility of
producing hot water for free. The base, the
structure and the panels are made of steel treated with rustproof polyester paint.

Unit with 2/3 refrigerant circuits designed to


intervention on the unit via a menu available
provide maximum efficiency at full load,
in several languages.
ensuring high efficiency at partial loads also
Adjustment includes complete management
and ensuring continuity in case one of the
of the alarms and their log.
circuits stops.
- The presence of a programmable timer
The full range uses aluminium microchannel
allows setting time bands of operation and a
coils, ensuring very high levels of efficiency.
possible second set-point
This allows using less refrigerant compared
- The temperature control takes place with the
to traditional copper coils.
integral proportional logic, based on the
The possibility of using the electronic therwater output temperature.
mostatic valve brings significant benefits, in - Night Mode: it is possible to set a silenced
Versions
particular when the refrigerant is working at
operation profile.
NSM_ Standard
partial loads to the benefit of energy effiPerfect for night operation, since it guaranteNSM_L Standard low noise
ciency of the unit. It is supplied as standard
es greater acoustic comfort in the evenings,
NSM_A High efficiency
from size 52026402 and 84039603,
and a high efficiency in the time of greater
NSM_E High efficiency low noise
optional for all other sizes.
load.
NSM_U Very high efficiency
Standard differential pressure switch
NSM_N Very high efficiency low noise
Possibility of integrated hydronic kit that
T Night Mode is standard on all low noise versions. For all other versions either the DCPX
encloses the main hydraulic components; it
accessory or J inverter fan must be specified to
Range of operation: Work up to 50C of
is available in different configurations with
allow Night Mode to operate.
outdoor air temperature at full load, depending
one or two pumps, with different static preson size and version. For further details refer to
sures available
the selection software/technical documenta Microprocessor adjustment, with keyboard
tion.
and LCD display, for easy consultation and

256

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and

remote control max. 18 units in RS485 network with integrated GPRS modem;
PRV3: Remote control of the chiller operating
functions.
MULTICHILLER_PCO: Control system for
multiple parallel installed constant flow chillers providing individual chiller on/off and
control capability.
DCPX: Device for condensation temperature
control, with continuous speed modulation
of fans by using a pressure transducer.
Standard in to low noise version or with desuperheater.
AVX: Spring anti-vibration mounts.

Accessories factory fitted only


KRS: Evaporator trace heating
KRSDES/KRSREC: Electrical resistor for desuperheater or total recovery
RIFNSM: Power factor correction. Connected
in parallel to the motor allowing about 10%
reduction of input current
GP: Anti-intrusion grids
AK: ACOUSTIC KIT. (only version L/E/N)
This accessory allows further sound reduction. Must be requested at time of order and
is available factory fitted only.

Compatibility of accessories
Mod. NSM
AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
DCPX

vers.

(1)

L
A
E
U
N

AVX

Accessories factory fitted only


KRS
(1)
KRS_DES
(1)(2)
KRS_REC
(1)(2)
RIFNSM
(1)
GP
(1)
AK
(3)

AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
DCPX

(1)

AVX

Accessories factory fitted only


KRS
(1)
KRS_DES
(1)(2)
KRS_REC
(1)(2)
RIFNSM
(1)
GP
(1)
AK
(3)

L
A
E
U
N

1402
(x2)

1602
(x2)

1802
(x2)

2002
(x2)

2202
(x2)

2352
(x2)

2502
(x2)

2652
(x2)

2802
(x2)

3002
(x2)

3202
(x2)

3402
(x2)

3602
(x2)

3902
(x2)

4202
(x2)

4502
(x2)

900
901
901
901
901
902

900
901
901
901
901
902

900
901
901
902
902
903

904
904
904
905
905
903

904
905
905
905
905
903

904
905
905
903
903
906

904
905
905
903
903
906

904
903
903
906
906
907

904
903
903
906
906
907

905
903
903
906
906
907

905
903
903
906
906
907

908
909
909
907
907
912

908
909
909
907
907
910

911
907
907
912
912
913

911
907
907
910
910
913

909
912
912
910
910
917

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

3202

3402

3602

3902

4202

4502

4802
(x2)

5202
(x2)

5602
(x2)

6002
(x2)

6402
(x2)

6503
(x3)

6703
(x3)

6903
(x3)

7203
(x3)

8403
(x3)

9603
(x3)

909
912
912
913
913
918

907
912
912
913
913
919

907
910
910
920
920
921

907
913
913
917
917
922

912
913
913
918
918
923

914
924
924
925
925
926

914
924
924
927
927
-

915
925
925
927
927
-

916
925
925
928
928
-

916
927
927
-

916
926
926
-

4802

5202

5602

6002

6402

6503

6703

6903

7203

8403

9603

(1) Accessories to be defined for compatibility


(2) The accessory is standard equipped with the electric resistance for the evaporator also
(3) The accessory is only available for the "L/E/N" silenced versions
(x2) Indicates the amount to order

257

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7

Y
X
Z
9

C
10

D
T
11

L
A
E
U
N
12

O
R
S
13

M
J
14

8
2
4
5
9
15-16
00
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
DA
DB
DC
DD
DE
DF
DG
DH
DI
DJ

Description
NSM
Sizes
1402-1602-1802-2002-2202-2352-2502-2652-2802-3002-3202 (dual circuit)
3402-3602-3902-4202-4502-4802-5202-5602-6002-6402 (dual circuit)
6503-6703-6903-7203-8403-9603 (triple circuit)
Operational limits
Standard (temperature of water produced up to +4 C)
Low temperature (temperature of water produced from +4C a -6C) (4)
Electronic thermostatic valve (temperature of water produced up to +4 C) (5)
Low temperature electronic thermostatic valve (temperature of water produced from +4C a -6C) (4)
Model
Cooling Only
Motor condensing unit (6)
Heat recovery
Without heat recovery
With desuperheater
With total recovery (7)
Version
Standard
Low noise Standard
High efficiency
Low noise high efficency
Very high efficiency
Low noise very high efficiency
Coils
Aluminium microchannel
Painted aluminium microchannel
Copper - Copper
Copper - Thinned
Fans
Standard
increased
Inverter
Power supply
400V/3/50Hz with fuses
400V/3/50Hz with magnet circuit breakers
230V/3/50Hz with fuses (8)
230V/3/50Hz with magnet circuit breakers (8)
500V/3/50Hz with fuses (9)
500V/3/50Hz with magnet circuit breakers (9)
Integrated hydronic kit
Without hydronic kit
Pumping unit (pump A)
Pumping unit (pump B)
Pumping unit (pump C)
Pumping unit (pump D)
Pumping unit (pump E)
Pumping unit (pump F)
Pumping unit (pump G)
Pumping unit (pump H)
Pumping unit (pump I)
Pumping unit (pump J)
Pumping unit (pump A and stand-by pump)
Pumping unit (pump B and stand-by pump)
Pumping unit (pump C and stand-by pump)
Pumping unit (pump D and stand-by pump)
Operation of pumps in parallel
Pumping unit (pump E and stand-by pump)
TF Double static pressure pump (pump F)
Pumping unit (pump F and stand-by pump)
TG Double static pressure pump (pump G)
Pumping unit (pump G and stand-by pump)
TH Double static pressure pump (pump H)
Pumping unit (pump H and stand-by pump)
TI Double static pressure pump (pump I)
Pumping unit (pump I and stand-by pump)
TJ Double static pressure pump (pump J)
Pumping unit (pump J and stand-by pump)

(4) The Y/Z option is not compatible with motor condensing units C; with option D and T
(5) sizes from 52026402 and 84039603 come standard with the electronic thermostatic valve
(6) The motor condensing units are not configurable with option D and T, and with the integrated hydronic kit
(7) The models with total recovery are not configurable with the integrated hydronic kit
(8) 230V/3/50Hz available only for sizes from 14022202
(9) 500V/3/50Hz available only for sizes from 14023202

258

Technical Data
Mod NSM

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

1402

1602

1802

2002

2202

2352

2502

2652

307
302
315
319
331
330
105
103
99
102
99
98
2,93
2,94
3,18
3,14
3,36
3,36
3,85
3,98
4,07
4,15
4,25
4,27
52940
52070
54340
55020
57000
56780
27
27
30
15
17
16

348
343
359
368
378
375
121
117
114
117
114
113
2,88
2,93
3,16
3,14
3,33
3,31
3,85
3,95
4,04
4,12
4,21
4,21
60070
59230
62020
63440
65100
64620
36
36
39
14
15
15

396
392
414
417
432
431
139
136
134
132
129
128
2,85
2,89
3,10
3,15
3,35
3,38
3,80
3,87
3,96
4,15
4,24
4,30
68350
67610
71500
71880
74380
74340
38
38
43
18
19
19

449
428
461
472
481
474
153
156
148
150
146
145
2,94
2,74
3,11
3,15
3,30
3,27
3,90
3,88
3,97
4,09
4,18
4,16
77550
73680
79420
81320
82910
81660
49
18
21
21
21
21

488
490
509
514
527
516
166
168
162
165
161
160
2,93
2,92
3,14
3,11
3,27
3,22
3,90
3,93
4,02
4,05
4,14
4,09
84280
84500
87700
88500
90820
88980
57
24
26
24
25
24

524
513
544
542
564
550
181
179
174
174
169
169
2,90
2,86
3,13
3,12
3,33
3,26
3,85
3,92
4,01
4,13
4,22
4,14
90320
88440
93790
93500
97200
94830
26
25
28
26
28
28

543
537
576
579
589
578
194
193
183
186
178
178
2,80
2,79
3,14
3,11
3,30
3,24
3,85
3,92
4,02
4,09
4,18
4,12
93610
92500
99310
99770
101640
99590
28
28
32
30
31
30

576
582
620
614
634
620
210
203
197
195
190
190
2,74
2,87
3,14
3,15
3,33
3,26
3,80
3,92
4,01
4,13
4,22
4,14
99370
100420
106880
105880
109280
106780
33
33
37
24
25
25

1402

1602

1802

2002

2202

2352

2502

2652

182
173
175
171
173
165

207
196
198
196
197
190

229
218
223
214
218
207

257
254
250
245
248
237

281
277
278
272
275
265

306
297
298
288
292
281

329
319
314
309
309
297

356
336
340
324
330
317

2
2

2
2

2
2

2
2

2
2

2
2

2
2

2
2

8
10
10
12
12
14
128000
115000
160000
138000
192000
161000

8
10
10
12
12
14
128000
115000
160000
138000
192000
161000

8
12
12
14
14
16
144000
138000
192000
161000
224000
184000

98
91
98
91
99
91

98
91
98
91
99
91

98
91
99
92
99
92

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
GENERAL DATA
Electrical data

Total input current

Compressors
Compressors
Circuits
Refrigerant
System side exchanger
exchanger
Fans standard

fans

Air flow rate cooling mode

(1)
(1)
(1)
(1)
(1)
(1)

L
A
E
U
N

all

L
A
E
U
N

L
A
E
U
N

A
A
A
A
A
A
type
n
n
type
type
n
type
n
n
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

two screw

6
8
8
8
8
10
96000
92000
128000
92000
128000
115000

6
8
8
8
8
10
96000
92000
128000
92000
128000
115000

6
8
8
10
10
12
96000
92000
128000
115000
160000
138000

97
89
97
89
97
90

97
89
97
89
97
90

97
89
98
90
98
91

R134a
Shell and tube
1
1
axial
8
8
8
10
8
10
10
10
10
10
12
12
128000
128000
92000
115000
128000
160000
115000
115000
160000
160000
138000
138000

Sound data

Sound power

Power supply

L
A
E
U
N

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

98
98
89
90
98
98
90
90
98
98
91
91
400V/3/50Hz

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

259

Technical Data
Mod NSM

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

2802

3002

3202

3402

3602

3902

4202

4502

613
602
658
651
674
658
227
215
208
210
204
204
2,70
2,79
3,16
3,10
3,30
3,22
3,80
3,94
4,03
4,09
4,18
4,09
105660
103770
113420
112240
116220
113450
35
31
37
26
28
27

679
663
698
694
707
700
233
238
224
224
214
217
2,92
2,78
3,12
3,10
3,30
3,22
3,90
3,90
3,99
4,09
4,18
4,09
117140
114370
120390
119690
121900
120680
39
36
40
29
30
29

723
708
741
740
750
742
248
261
237
239
228
231
2,92
2,71
3,12
3,10
3,29
3,21
3,85
3,89
3,99
4,07
4,16
4,08
124820
122040
127660
127460
129220
127920
42
23
25
26
26
26

768
770
799
795
810
802
272
265
253
255
245
248
2,82
2,90
3,15
3,12
3,30
3,24
3,85
3,94
4,03
4,09
4,18
4,12
132560
132690
137790
137080
139610
138210
47
23
25
25
26
25

812
825
883
880
901
878
298
297
281
284
273
270
2,72
2,78
3,14
3,10
3,30
3,25
3,80
3,92
4,01
4,08
4,17
4,11
140070
142180
152180
151730
155320
151390
38
25
29
29
30
30

904
907
953
950
974
953
316
316
304
306
295
293
2,86
2,87
3,14
3,11
3,30
3,26
3,90
3,92
4,01
4,09
4,18
4,11
155970
156420
164390
163810
167910
164440
46
32
36
36
37
37

956
948
1019
1017
1041
1012
346
349
329
326
315
316
2,76
2,72
3,10
3,12
3,30
3,21
3,80
3,87
3,97
4,09
4,18
4,07
164980
163450
175850
175370
179580
174590
41
34
39
40
42
40

1048
1030
1082
1079
1102
1084
360
366
347
347
337
333
2,91
2,81
3,12
3,11
3,27
3,26
3,90
3,89
3,98
4,05
4,14
4,09
180930
177710
186660
186260
190140
186920
48
44
49
49
51
35

2802

3002

3202

3402

3602

3902

4202

4502

381
354
355
347
352
339

392
391
378
367
366
358

414
426
399
389
387
378

447
429
421
411
410
399

484
473
459
450
448
429

520
509
502
490
490
470

573
567
547
529
530
513

597
593
577
560
562
540

2
2

2
2

2
2

2
2

2
2

2
2

2
2

2
2

10
14
14
16
16
20
180000
161000
224000
184000
256000
230000

12
16
16
18
18
22
216000
184000
256000
207000
288000
253000

12
16
16
20
20
22
216000
184000
256000
230000
320000
253000

14
18
18
20
20
26
252000
207000
288000
230000
320000
299000

101
92
100
93
100
93

101
93
100
94
101
93

101
93
100
94
101
94

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
GENERAL DATA
Electrical data

Total input current

(1)
(1)
(1)
(1)
(1)
(1)

L
A
E
U
N

Compressors
Compressors
Circuits
Refrigerant
System side exchanger
Exchanger

/L/A/E/U
N

Fans standard

fans

Air flow rate cooling mode

L
A
E
U
N

L
A
E
U
N

A
A
A
A
A
A
type
n
n
type
type
n
n
type
n
n
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

two screw

R134a
Shell and tube
1
1

8
12
12
14
14
16
144000
138000
192000
161000
224000
184000

10
12
12
14
14
16
180000
138000
192000
161000
224000
184000

10
12
12
14
14
16
180000
138000
192000
161000
224000
184000

10
14
14
16
16
18
180000
161000
224000
184000
256000
207000

98
91
99
92
99
92

99
91
99
92
99
92

100
91
99
92
99
92

axial

Sound data

Sound power

Power supply

L
A
E
U
N

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

100
100
91
91
99
99
93
93
100
100
93
93
400V/3/50Hz

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

260

Technical Data
Mod NSM

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

4802

5202

5602

6002

6402

6503

6703

6903

1096
1074
1157
1157
1182
1167
388
395
372
371
357
353
2,82
2,72
3,11
3,12
3,31
3,31
3,85
3,89
3,98
4,10
4,18
4,10
189160
185350
199680
199490
203880
201310
42
46
53
36
38
44

1165
1120
1211
1204
1231
1216
403
429
389
388
380
375
2,89
2,61
3,11
3,11
3,24
3,25
3,90
3,88
3,97
4,01
4,09
4,13
201040
193220
208790
207680
212380
209810
46
33
38
38
40
44

1192
1181
1273
1264
1299
1265
431
443
411
406
401
397
2,77
2,67
3,10
3,12
3,24
3,19
3,85
3,90
3,99
4,02
4,10
4,05
205680
203720
219570
217720
223920
218040
48
36
42
24
26
26

1234
1251
1349
1320
1359
1315
453
453
433
422
418
410
2,72
2,76
3,12
3,13
3,25
3,20
3,80
3,89
3,98
4,02
4,11
4,07
213030
215910
232740
227490
234170
226640
55
42
49
24
26
26

1323
1292
1399
1387
1417
1365
460
477
451
444
428
428
2,87
2,71
3,10
3,13
3,31
3,19
3,85
3,87
3,96
4,10
4,19
4,05
228500
222970
241410
239130
244270
235280
62
45
52
29
31
30

1390
1393
1459
1462
1502
1450
489
492
466
469
453
450
2,85
2,83
3,13
3,12
3,31
3,22
3,90
3,91
4,00
4,10
4,19
4,09
239870
240090
251620
252090
259100
249980
44
33
36
35
37
37

1436
1434
1529
1525
1576
n.d.
517
524
493
489
473
n.d.
2,78
2,74
3,10
3,12
3,33
n.d.
3,80
3,87
3,96
4,12
4,22
n.d.
247790
247230
263620
262970
271780
n.d.
46
34
39
40
42
n.d.

1576
1601
1678
1666
1689
n.d.
560
557
535
534
522
n.d.
2,82
2,87
3,14
3,12
3,23
n.d.
3,85
3,92
4,01
4,01
4,09
n.d.
271650
276220
289610
287420
291410
n.d.
30
45
49
49
51
n.d.

4802

5202

5602

6002

6402

6503

6703

6903

641
638
614
598
597
569

668
693
647
628
634
605

712
716
685
656
671
643

749
736
725
686
706
668

766
776
758
724
725
700

806
793
772
764
762
731

857
849
821
792
795
n.d.

927
914
897
861
870
n.d.

2
2

2
2

2
2

2
2

2
2

3
3

3
3

3
3

1
2
2
2
2
2

1
2
2
2
2
n.d.

1
2
2
2
2
n.d.

18
24
24
28
28
34
324000
276000
384000
322000
448000
391000

18
24
24
30
30

20
28
28
30
30

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
GENERAL DATA
Electrical data

Total input current

(1)
(1)
(1)
(1)
(1)
(1)

L
A
E
U
N

Compressors
Compressors
Circuits
Refrigerant
System side exchanger

Exchanger

L
A
E
U
N

Ventilatori standard

fans

Air flow rate cooling mode

L
A
E
U
N

L
A
E
U
N

A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
n
n
type
n
n
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

two screw

1
1
1
1
1
2

1
1
1
1
1
2

1
1
1
2
2
2

14
18
18
22
22
28
252000
207000
288000
253000
352000
322000

16
18
18
22
22
30
288000
288000
324000
253000
352000
345000

16
20
20
24
24
32
288000
320000
360000
276000
384000
368000

101
93
101
94
101
94

102
93
102
94
102
95

102
94
102
94
102
95

R134a
Shell and tube
1
1
1
1
1
1
2
2
2
2
2
2
axial
16
18
22
22
22
22
26
28
26
28
32
32
288000
324000
352000
352000
396000
396000
299000
322000
416000
448000
368000
368000

n.d.

n.d.

324000
276000
384000
345000
480000

360000
322000
448000
345000
480000

n.d.

n.d.

102
94
102
94
102

103
94
102
94
102

n.d.

n.d.

Sound data

Sound power

Power supply

L
A
E
U
N

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

102
102
94
94
102
102
94
94
102
102
95
95
400V/3/50Hz

102
94
102
94
102
95

n.d. versions not available

261

Technical Data
Mod NSM

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

L
A
E
U
N

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kPa
kPa

7203

8403

9603

1667
1645
1748
1749
1768
n.d.
575
587
560
563
541
n.d.
2,90
2,80
3,12
3,11
3,27
n.d.
3,85
3,90
3,99
4,05
4,14
n.d.
287330
283850
301740
301590
305050
n.d.
33
47
53
45
46
n.d.

1739
1754
1904
n.d.
n.d.
n.d.
659
660
614
n.d.
n.d.
n.d.
2,64
2,66
3,10
n.d.
n.d.
n.d.
3,80
3,87
3,96
n.d.
n.d.
n.d.
299790
302520
328430
n.d.
n.d.
n.d.
36
34
41
n.d.
n.d.
n.d.

1856
1941
2100
n.d.
n.d.
n.d.
731
714
673
n.d.
n.d.
n.d.
2,54
2,72
3,12
n.d.
n.d.
n.d.
3,80
3,89
3,99
n.d.
n.d.
n.d.
320050
334990
362460
n.d.
n.d.
n.d.
40
45
52
n.d.
n.d.
n.d.

7203

8403

9603

966
960
936
898
896
n.d.

1103
1067
1017
n.d.
n.d.
n.d.
two screw
3
3
R134a
shell and tube
1
2
2
n.d.
n.d.
n.d.
axial
22
30
30
n.d.
n.d.
n.d.
396000
345000
480000
n.d.
n.d.
n.d.

1230
1163
1132
n.d.
n.d.
n.d.

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
GENERAL DATA
Electrical data

Total input current

(1)
(1)
(1)
(1)
(1)
(1)

L
A
E
U
N

Compressors
Compressors
Circuits
Refrigerant
System side exchanger

Exchanger

L
A
E
U
N

Standard fans

fans

Air flow rate cooling mode

L
A
E
U
N

L
A
E
U
N

A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
n
n
type
n
n
n
n
n
n
m3/h
m3/h
m3/h
m3/h
m3/h
m3/h

3
3

1
2
2
2
2
n.d.
22
28
28
32
32
n.d.
396000
322000
448000
368000
512000
n.d.

3
3

1
2
2
n.d.
n.d.
n.d.
22
34
34
n.d.
n.d.
n.d.
396000
490000
588000
n.d.
n.d.
n.d.

Sound data

Sound power

Power supply

L
A
E
U
N

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

103
94
102
95
102
n.d.

103
94
103
n.d.
n.d.
n.d.
400V/3/50Hz

103
95
104
n.d.
n.d.
n.d.

(1) The electrical data of the versions without hydronic module integrated
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

262

Dimensions (mm)

Mod. NSM
Height
Width

(mm)
(mm)

A
B

Depth

(mm)

Mod. NSM
Height
Width

(mm)
(mm)

A
B

Depth

(mm)

Mod. NSM
Height
Width

(mm)
(mm)

A
B

Depth

Mod. NSM
Height
Width

Depth

(mm)

(mm)
(mm)

(mm)

A
B

Vers
all
all

L
A
E
U
N

Vers
all
all

L
A
E
U
N

Vers
all
all

L
A
E
U
N

Vers
all
all

L
A
E
U
N

1402
2450
2200
3970
5160
5160
5160
5160
6350

1602
2450
2200
3970
5160
5160
5160
5160
6350

1802
2450
2200
3970
5160
5160
6350
6350
7140

2002
2450
2200
5160
5160
5160
6350
6350
7140

2202
2450
2200
5160
6350
6350
6350
6350
7140

2352
2450
2200
5160
6350
6350
7140
7140
8330

2502
2450
2200
5160
6350
6350
7140
7140
8330

2652
2450
2200
5160
7140
7140
8330
8330
9520

2802
2450
2200
5160
7140
7140
8330
8330
9520

3002
2450
2200
6350
7140
7140
8330
8330
9520

3202
2450
2200
6350
7140
7140
8330
8330
9520

3402
2450
2200
6350
8330
8330
9520
9520
10710

3602
2450
2200
6350
8330
8330
9520
9520
11900

3902
2450
2200
7140
9520
9520
10710
10710
13090

4202
2450
2200
7140
9520
9520
11900
11900
13090

4502
2450
2200
8330
10710
10710
11900
11900
15470

4802
2450
2200
8330
10710
10710
13090
13090
16660

5202
2450
2200
9520
10710
10710
13090
13090
17850

5602
2450
2200
9520
11900
11900
14280
14280
19040

6002
2450
2200
9520
13090
13090
15470
15470
19040

6402
2450
2200
10710
13090
13090
16660
16660
19040

6503
2450
2200
11110
14280
14280
16660
16660
20230

6703
2450
2200
11110
14280
14280
17850
17850

6903
2450
2200
11900
16660
16660
17850
17850

n.d.

n.d.

7203
2450
2200
13090
16660
16660
19040
19040

8403
2450
2200
13090
17850
17850

9603
2450
2200
13090
20230
20230

n.d.
n.d.
n.d.

n.d.
n.d.
n.d.

n.d.

For transport reasons, the sizes of the units with the depth of more than 13090 mm are shipped separately. For more information, please refer to the
technical manual and / or installation.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

263

Cod.: SNSMUY.00 / 1408

NSH
1251/2002

Heat pump

Reversible heat pumps


Air/Water outdoor installation
Axial fans and twin-rotor screw compressor
Cooling capacity 236732kW
Heating capacity 275786kW

R134a
AERMEC
partecipates in the EUROVENT
programme for:LCP
Check ongoing validity of
certificate online:
www.eurovent-certification.com

STANDARD VERSION
HIGH EFFICIENCY VERSION
HIGH EFFICIENCY EVEN AT PART LOAD
1/2 REFRIGERANT CIRCUIT
OPTION VERSION WITH BUILT-IN HYDRONIC KIT
ELECTRONIC EXPANSION VALVE

Characteristics
100%.
Electronic expansion valve as a standard
Economiser circuit with plate heat exchanger
for improved performance, particularly at
high compression ratios, as experienced in
heating mode at low ambients
Generously sized refrigerant circuit for minimum pressure drop
Shell and tube evaporator optimised for
refrigerant R134a.
Pressure switch as standard supply
Option integrated hydronic mudule, it consist of 1
or 2 pumps and 2 exspansion tanks (25l.)
1/2 refrigerant circuits
Axial fans for extremely quiet operation
High efficiency, low noise screw compressors Modulating capacity control microprocessor
with modulating capacity control from 25 to
system

Reversible heat pumps


Version
NS_H Standard version
NS_HL Standard low noise version
NS_HA High efficiency version
NS_HE High efficiency low noise version
Operational limits (1)
- max. external air temperature 48C
in cooling mode
- Maximum leaving water temperature 55C
in fheating mode

Multilingual display panel


Compact sizes
Metal control panel with anti-corrosion polyester paint
Options for partial or total heat recovery
The low nois version "L/E" is equipped:
- Compressor acoustical enclosure
- Fan speed control (DCPX)
- Hot gas discharge muffler.

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 net-

264

work with integrated GPRS modem;


reduction of input current.
PRV3: Remote control of the chiller operating GP: Protective grille. Condenser coil external
functions.
protection against accidental or hail damage.
MULTICHILLER: Control system for multiple
AK: ACOUSTIC KIT
parallel installed constant flow chillers pro(only for Versions L and E)
viding individual chiller on/off and control
This accessory allows further sound reduccapability.
tion. Must be requested at time of order and
DCPX: Low ambient device for cooling operais available factory fitted only.
tion below 20C down to -10C.
AVX: Spring anti-vibration
Accessories factory fitted only
KRS: Evaporator trace heating.
KRSDES/KRSREC: Evaporator and heat recovery exchangers trace heating.
RIFNS: Power factor correction. Connected in
parallel to the motor allowing about 10%

Compatibility of accessories
Mod. NS
AER485P1
AERWEB300

vers.

PRV3

Alls

MULTICHILLER
DCPX

Alls

69

69

69

69

68

68

68

73

73

73

73

73

73

73

73

73

73

537

538

541

542

544

545

547

549

549

552

552

557

558

537
537
537
538
538

538
538
538
538
538

541
541
541
541
541

543
543
543
543
543

544
544
544
544
544

546
546
546
546
546

547
547
547
548
548

549
549
549
550
550

550
550
550
550
550

553
553
553
553
553

553
555
555
555
555

557
557
557
557
557

558
558
558
558
558

537

538

541

543

543

545

549

551

551

554

556

557

559

537
538
538
538
538

538
538
538
538
538

541
541
541
541
541

543
543
543
543
543

543
543
543
543
543

545
545
545
545
545

550
550
550
550
550

551
551
551
551
551

551
551
551
551
551

553
553
553
553
553

553
555
555
555
555

557
557
557
557
557

559
559
559
559
559

Alls
Alls

(1) Alls

1251 1401 1601 1801 1402 1602 1802 2002 2202 2352 2502 2652 2802 3002 3202 3402 3602
(x1) (x1) (x1) (x1) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2)

Spring antivibration for unit without Hydronik kit "00"


H/HL
536 536 536 539
AVX
Spring antivibration for unit with Hydronik kit
AVX
PA H/HL
536 536 536 539
AVX
PC H/HL
536 536 536 540
AVX
PE H/HL
536 536 536 540
AVX
PG H/HL
536 536 536 540
AVX
PJ H/HL
536 536 536 540
Spring antivibration for unit without Hydronik kit "00"
HA/HE 536
536 536 540
AVX
Spring antivibration for unit with Hydronik kit
AVX
PA HA/HE 536 536 536 540
AVX
PC HA/HE 536 536 536 540
AVX
PE HA/HE 536 536 536 540
AVX
PG HA/HE 536 536 536 540
AVX
PJ HA/HE 536 536 536 540

Accessories factory fitted only


KRS11 KRS11 KRS11 KRS11 KRS19 KRS19 KRS19 KRS19 KRS19 KRS19 KRS19 KRS19 KRS19 KRS14 KRS14 KRS14 KRS14
KRS
KRS11DES KRS11DES KRS11DES KRS11DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS14DES KRS14DES KRS14DES KRS14DES
KRS_DES
(2)
RIFNSH
1251 1401 1601 1801 1402 1602 1802 2002 2202 2352 2502 2652 2802 3002 3202 3402 3602
GP300M

GP400M

GP300B

GP400B

GP500B

GP300M+300M

GP300M+400M

GP400M+400M

AK
(3)

(1) IDCPX Accessory supplied as standard on Versions L, E, and D


(2) Accessory comes standard wit the electrical heater for evaporator and desuperheater
(3) Accessory is only available for the low noise verion "L/E"
(x2) the number in brackets indicates the quantity to order

265

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Field
1,2
3,4,5,6

7
X
8
H
9

D
10

L
A
E
11

R
S
V
12

J
13

2
4
5
8
9
14-15
00
PA
PC
PE
PG
PJ

Code
NS
Size
1251-1401-1601-1801 (single module 1 circuits)
1402-1602-1802-2002-2202-2352-2502-2652-2802 (single module 2 circuits)
3002-3202-3402-3602 (double module 2 circuits)
Expansion valve:
Electronic expansion valve (leaving water temperature down to 4C) contact head office for lower temperatures
Model
Heat pumps
Heat recovery
Without recovery
With Desuperheater
Version
Standard
Standard in low noise operation
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans
Standard
Inverter
Power supply
400V/3/50Hz with fuses
230V/3/50Hz with fuses (5)
230V/3/50Hz with circuit breakers (5)
500V/3/50Hz with fuses (6)
400V/3/50Hz with circuit breakers
500V/3/50Hz with circuit breakers (6)
Hydronic kit
Without hydronic kit
Hydronic pump (Pump A)
Hydronic pump (Pump C)
Hydronic pump (Pump E)
Hydronic pump (Pump G)
Hydronic pump (Pump J)

(4)The desuperheater ca be used exclusively in the col operation


(5) 230V/3/50Hz is not available for size 12511801/23523602
(6) 500V/3/50Hz is not available for size 1801-3402-3602

266

Technical Data
Mod NS_H Heat pump

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

Heating capacity
Total input power
COP
Water flow rate
Total pressure drop

H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

1251
244
235
262
250
91,82
94,77
86,93
91,8
2,66
2,48
3,01
2,73
3,15
3,09
3,51
3,36
42140
40592
45236
43172
34
32
38
32
276
282
93,08
88,07
2,97
3,2
47300
48332
42
43

1401
260
250
281
266
100,7
105,64
95,02
101,92
2,59
2,37
2,96
2,61
3,04
2,94
3,44
3,21
44892
43172
48504
45924
25
23
41
37
292
298
98,9
94,16
2,95
3,17
50052
51084
30
45

1601
296
280
309
291
111,02
116,92
107,82
115,73
2,67
2,4
2,87
2,52
3,14
2,97
3,31
3,09
51084
48332
53320
50224
39
35
27
24
337
333
111,37
103,94
3,03
3,2
57792
57104
49
30

1801
353
335
365
343
135
140,94
128,32
136,13
2,61
2,38
2,84
2,52
3,07
2,96
3,3
3,1
60888
57792
62952
59168
32
30
43
38
382
394
130,21
126,59
2,94
3,12
65532
67596
37
49

1402
241
227
257
242
97,8
100,72
94,88
100,8
2,47
2,26
2,71
2,4
3,02
2,9
3,23
3,05
41624
39216
44376
41796
33
30
36
33
273
282
97,99
93,07
2,79
3,03
46784
48332
41
43

1602
298
285
315
301
111,9
118,84
108,33
116,19
2,66
2,4
2,9
2,59
3,25
3,07
3,48
3,29
51428
49192
54352
51944
32
30
50
46
341
344
113,21
106,63
3,01
3,22
58480
58824
42
59

1802
342
327
365
349
131,18
138,06
125,32
132,17
2,61
2,37
2,91
2,64
3,18
3,05
3,49
3,33
58996
56416
62952
60200
40
37
43
39
381
397
129,5
123,6
2,95
3,21
65360
67940
48
50

2002
366
354
384
366
135,38
138,29
132,49
140,32
2,7
2,56
2,89
2,61
3,29
3,27
3,48
3,3
63124
61060
66220
63124
45
43
47
43
412
413
142,8
133,76
2,88
3,09
70520
70864
55
54

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.

267

Technical Data
GENERAL DATA
Electrical data
Total input current
cooling mode
Total input current
heating mode
Maximum current (FLA)
Starting current (LRA)

(1)
H
(1) HL
(1) HA
(1) HE
(1) H/HL
(1) HA/HE
H/HL
HA/HE
H/HL
HA/HE

A
A
A
A
A
A
A
A
A
A

1251

1401

1601

1801

1402

1602

1802

2002

157
166
149
161
159
150
209
209
327
327

174
185
164
178
171
163
242
242
387
387

189
204
185
202
189
180
258
258
431
431

226
242
215
234
218
212
316
316
472
472

173
182
168
181
173
165
276
276
251
251

192
207
186
202
193
182
276
276
251
251

225
241
216
233
223
213
325
325
305
305

232
245
227
246
242
229
352
352
313
313

1
1

1
1

1
1

1
1

2
2

2
2

2
2

Compressors
type
n
n
%
type

40-100

40-100

40-100

40-100

20-100

20-100

20-100

20-100

R134a

R134a

R134a

R134a

R134a

R134a

R134a

R134a

Alls

type
n

1
6"

1
6"

1
6"

2
6"

2
6"

2
6"

Alls
H
HL
HA
HE

type
n
m3/h
m3/h
m3/h
m3/h

axial
6
128400
89880
117600
82320

axial
6
128400
89880
117600
117600

axial
axial
axial
axial
6
8
6
6
120000
171200
128400
120000
84000
119840
89880
84000
112200
156000
117600
112200
78540
109200
82320
78540
refer to the technical manual
refer to the technical manual

axial
8
171200
119840
153200
107240

axial
10
214000
149800
196000
137200

61,5
56,5
93,5
88,5
400V/3

61,5
56,5
93,5
88,5
400V/3

62,5
57,5
94,5
89,5
400V/3

63,5
58,5
96,0
91,0
400V/3

64,0
59,0
96,5
91,5
400V/3

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans

Air flow rate cooling mode


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure
Sound power
Power supply

two screw

kPa
H/HA
HL/HE
H/HA
HL/HE

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

2
2

Shell and tube


1
2
6"
6"

63,5
58,5
96,0
91,0
400V/3

62,0
57,0
94,0
89,0
400V/3

63,0
58,0
95,0
90,0
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Electronic expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

268

Technical Data
Mod NS_H Heat pump

Cooling capacity

Total input power

EER

ESEER

Water flow rate

Total pressure drop

Heating capacity
Total input power
COP
Water flow rate
Total pressure drop

H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE
HA/HE

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

2202
394
380
413
393
145
149
139
146
2,71
2,55
2,98
2,68
3,30
3,26
3,56
3,40
67940
65532
71380
67940
40
37
53
48
437
452
147
141
2,98
3,20
74820
77400
47
62

2352
432
414
454
435
167
175
158
169
2,58
2,36
2,86
2,57
3,12
3,04
3,41
3,25
74476
71380
78260
74992
35
34
37
34
481
504
166
158
2,90
3,19
82388
86344
43
45

2502
465
444
498
486
183
193
173
192
2,54
2,3
2,87
2,53
3,07
2,95
3,44
3,18
80324
76712
86000
83936
41
38
38
35
525
543
177
171
2,97
3,18
89956
93052
46
43

2652
490
468
523
505
194
205
187
202
2,53
2,28
2,8
2,5
3,05
2,92
3,36
3,15
84452
80668
90300
87204
23
21
40
37
557
565
186
177
2,99
3,19
95632
96836
29
45

2802
518
491
546
516
198
211
196
211
2,61
2,33
2,79
2,45
3,17
2,98
3,33
3,11
89268
84624
94256
89096
25
22
43
39
589
587
195
185
3,01
3,17
101136
100620
32
49

3002
556
531
590
559
222
222
203
217
2,5
2,39
2,91
2,57
3,09
2,97
3,37
3,15
95976
91504
101824
96320
32
29
34
30
629
631
210
198
3,00
3,19
107844
108188
39
38

3202
592
560
619
585
222
233
215
231
2,67
2,4
2,87
2,53
3,14
2,98
3,31
3,09
102168
96664
106640
100792
39
35
27
24
674
666
222
208
3,03
3,21
115584
114208
49
30

3402
649
615
674
635
246
258
236
252
2,64
2,39
2,86
2,53
3,10
2,96
3,31
3,08
111972
106124
116272
109564
35
32
35
31
719
727
241
230
2,98
3,16
123324
124700
43
40

3602
706
670
730
686
270
282
256
272
2,62
2,38
2,85
2,52
3,07
2,96
3,30
3,09
121776
115584
125904
118336
32
30
43
38
764
789
260
253
2,94
3,12
131064
135192
37
50

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
Not certied model EUROVENT

269

Technical Data

GENERAL DATA
Electrical data
Total input current
cooling mode
Total input current
heating mode
Maximum current (FLA)
Starting current (LRA)

(1)
H
(1) HL
(1) HA
(1) HE
(1) H/HL
(1) HA/HE
H/HL
HA/HE
H/HL
HA/HE

A
A
A
A
A
A
A
A
A
A

2202

2352

2502

2652

2802

3002

3202

3402

3602

245
259
233
254
246
236
370
370
350
350

283
302
268
293
279
267
390
390
365
365

310
333
295
333
301
292
410
410
436
436

330
354
318
349
319
303
443
443
461
461

340
368
335
365
335
318
476
476
521
521

363
389
349
380
360
342
500
500
534
534

378
407
370
403
378
359
516
516
578
578

415
445
400
436
407
391
574
574
612
612

453
484
430
468
436
423
631
631
653
653

2
2

2
2

2
2

2
2

two screw
2
2

2
2

2
2

2
2

2
2

Compressors
type
n
n
%
type

20-100

20-100

20-100

20-100

20-100

20-100

20-100

20-100

20-100

R134a

R134a

R134a

R134a

R134a

R134a

R134a

R134a

R134a

Alls

type
n

1
6"

1
6"

1
6"

2
6"

2
6"

2
6"

2
6"

Alls
H
HL
HA
HE

type
n
m3/h
m3/h
m3/h
m3/h

axial
10
214000
149800
196000
137200

axial
10
214000
149800
196000
137200

axial
10
214000
149800
196000
137200

axial
12
240000
168000
224400
157080

axial
14
291200
203840
268200
187740

axial
16
342400
239680
312000
218400

64,0
59,0
96,5
91,5
400V/3

64,0
59,0
96,5
91,5
400V/3

64,5
59,5
97,0
92,0
400V/3

65,0
60,0
97,5
92,5
400V/3

65,5
60,5
98,5
93,5
400V/3

66,0
61,0
99,0
94,0
400V/3

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans

Air flow rate cooling mode


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure
Sound power
Power supply

kPa
H/HA
HL/HE
H/HA
HL/HE

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


1
1
6"
6"

axial
axial
axial
10
10
12
207000 200000 248400
144900 140000 173880
191500 187000 229800
134050 130900 196140
refer to the technical manual
refer to the technical manual
64,5
59,5
97,0
92,0
400V/3

64,5
59,5
97,0
92,0
400V/3

64,0
59,0
97,0
92,0
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Electronic expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

270

Dimensions (mm)

C
B
C
B

Mod. NS_H
Height
Width
Depth
Weight when
empty

A
B
C
H/HL
HA/HE

(kg)

Vers
(mm)
(mm)
(mm)
(kg)

A
B
C
H/HL
HA/HE

1251
2450
2200
3780
3150
3245

1401
2450
2200
3780
3165
3280

1601
2450
2200
3780
3340
3435

1801
2450
2200
4770
4005
4115

1402
2450
2200
3780
3475
3570

1602
2450
2200
3780
3800
3835

1802
2450
2200
4770
3930
4005

2002
2450
2200
5750
4290
4385

2352
2450
2200
5750
4735
4940

2502
2450
2200
5750
5090
5265

2652
2450
2200
5750
5210
5470

2802
2450
2200
5750
5330
5610

3002
2450
2200
7160
6330
6540

3202
2450
2200
7160
6555
6745

3402
2450
2200
8150
7220
7425

3602
2450
2200
9140
7885
8105

2202
2450
2200
5750
4355
4570

Cod.: SNSHUY.03 /1412

Mod. NS_H
Height
Width
Depth
Weight when
empty

Vers
(mm)
(mm)
(mm)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

271

NSI

Air cooled chillers


INVERTER screw compressors, axial fans
Cooling capacity 2621249 kW

R134a
HIGH

SEASONAL

Aermec
participate in the EUROVENT
program:LCP, the products are
present on the site
www.eurovent-certification.com

EFFICIENCY

New generation INVERTER


screw compressor

Characteristics

Cooling only version


Refrigerant R134a
New generation INVERTER screw compressor:
- Continuous capacity control from 15 to 100%
- With automatic control of compression ratio
- With opto-electronic control of oil level
AC Inverter:
- Refrigerant cooled
- With control of operating field
- With integrated data logger
High efficiency version A

Operating limit up to 46 C external air temperature


Compressor acoustical enclosure for low
noise operation
Electronic expansion valve
Dry expansion shell and tube evaporator optimised for refrigerant R134a
Extremely low noise axial fans with options:
- M high static pressure fans
- J inverter fans

Pump assembly option (see Unit


Configurator) that includes:
- 1 pump
- 1 pump plus 1 standby
- 2 expansion tanks of 25 litres
Microprocessor controller
Multilingual display
Compact dimensions
Metal control panel with anti-corrosion polyester paint.

AERWEB300-18G: Web server to monitor and


remote control max. 18 units in RS485 network with integrated GPRS modem;
PRV3: Remote control of the chiller operating
functions.
MULTICHILLER_PCO: Control system for
multiple parallel installed constant flow chillers providing individual chiller on/off and
control capability.
DCPX: Low ambient device for cooling operation below 19 C down to -10 C.
AVX: Spring anti-vibration mounts. For compatibility of the AVX mounts refer to the technical manual.

Accessories factory fitted only


KRS: Evaporator trace heating. Factory fitted
only.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
Factory fitted.

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;

272

Compatibility of accessories
Mod. NSI
AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
DCPX

1251
(x1)

69

1401
(x1)

69

1601
(x1)

69

1701
(x1)

69

1801
(x1)

69

2502
(x2)

73

2802
(x2)

73

3202
(x2)

73

3402
(x2)

73

3602
(x2)

73

4203 4803 5103 5403


(x3) (x3) (x3) (x3)

73+69 73+69 73+76 73+76

Accessories factory fitted only

GP300M
GP400M
GP500B
GP300M+GP300M
GP400M+GP400M
GP300M+GP300M+GP300M
GP400M+GP400M+GP400M
KRS
1.

(1)

Accessory available for all sizes, to t contact factory

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Configuration fields:
123
|
Code

4567
|
|
|
Size

8
|
Expansion
device

9
10
11
12
|
|
|
|
|
Heat recovery
|
|
|
|
Condenser coil
Model
Version

Code:
NSI
Size:
1251, 1401, 1601, 1701, 1801, 2502, 2802, 3202, 3402, 3602,
4203, 4803, 5103, 5403
Expansion device:
X - R134a electronic expansion valve, minimum leaving water
temperature down to +4 C
(for lower temperatures contact the factory)
Model:
- Cooling only
Heat recovery:
- Without heat recovery
Version:
A - High efficiency
Condenser coil:
- Aluminium
R - Copper
S - Tinned copper
V - Anti-corrosion coated aluminium

13
|
|
|
Fan

14
|
|
Power supply

15-16
|
|
|
Pump

Fan:
- Standard
M - High static pressure
J - Inverter
Power supply:
- 400V/3/50Hz with fuses
Pump:
00 - Without pump assembly
PA - Pump assembly (Pump A)
PB - Pump assembly (Pump A and standby pump)
PC - Pump assembly (Pump C)
PD - Pump assembly (Pump C and standby pump)
PE - Pump assembly (Pump E)
PF - Pump assembly (Pump E and standby pump)
PG - Pump assembly (Pump G)
PH - Pump assembly (Pump G and standby pump)
PJ - Pump assembly (Pump J)
PK - Pump assembly (Pump J and standby pump)

273

Technical Data
Mod. NSI
Cooling capacity
Total input power
Water ow rate
Pressure drop
EER
ESEER
Power supply
Total input current
Maximum current (FLA)
Starting current (LRA)
Capacity control

Vers

A
A
A
A
A
A
A
A
A
A

Compressors

Refrigerant
Refrigerant circuits
Air ow rate

A
A
A
A
A

Fans
Evaporator

Sound power
Maximum external air temp.

Mod. NSI
Cooling capacity
Total input power
Water ow rate
Pressure drop
EER
ESEER
Power supply
Total input current
Maximum current (FLA)
Starting current (LRA)
Capacity control

Vers

A
A
A
A
A
A
A
A
A
A

Compressors

Refrigerant
Refrigerant circuits
Air ow rate

A
A
A
A
A

Fans

kW
kW
l/h
kPa
W/W
W/W
V/ph/Hz
A
A
A
%
type
n
type
n
m3/h
type
n
type
n
dB(A)
C

Evaporator

Sound power
Maximum external air temp.

kW
kW
l/h
kPa
W/W
W/W
V/ph/Hz
A
A
A
%
type
n
type
n
m3/h
type
n
type
n
dB(A)
C

Data declared in accordance with


UNI EN 14511:2013
COOLING MODE
Entering water temperature
Leaving water temperature
External air temperature

274

1251
262
88
45240
36,0
2,98
4,69

1401
302
100
52110
46,9
3,02
4,68

140
180
18
24-100

159
211
18
20-100

1
116000

1
110000

1
94,9
46

1
96,7
46

3202
666
224
114730
25,2
2,97
4,64

3402
748
253
128970
37,1
2,95
4,63

358
483
121
9-100

403
550
126
9-100

2
212000

2
290000

12

16

2
101,5
46

2
101,2
46

1601
333
112
57370
25,2
2,96
4,64

1701
1801
374
416
127
140
64490
71800
37,1
33,5
2,95
2,97
4,63
4,67
430/3/50Hz
179
202
223
242
275
309
18
20
20
18-100
17-100
15-100
screw - inverter
1
1
1
R134a
1
1
1
106000
145000
136000
Axial
6
8
8
shell and tube evaporator
1
1
1
98,5
98,2
97,8
46
46
46
3602
833
280
143600
33,5
2,98
4,67

4203
4803
906
999
299
337
156340
172100
46,9
25,2
3,03
2,97
4,76
4,64
430/3/50Hz
446
476
537
618
632
725
126
225
225
9-100
7-100
7-100
screw - inverter
2
3
3
R134a
2
3
3
272000
330000
318000
Axial
16
18
18
shell and tube evaporator
2
3
3
100,8
101,5
103,3
46
46
46

Sound power:
Aermec determines sound power values on the basis
of measurements made in accordance with UNI EN
ISO 9614-2, as required for Eurovent certification.
12 C
7 C
35 C

2502
526
173
90720
47,3
3,03
4,78

2802
591
199
102170
58,8
2,97
4,69

275
357
119
12-100

315
416
119
12-100

2
180000

2
173000

10

10

1
97,9
46

1
99,7
46

5103
1122
380
193460
37,1
2,95
4,63

5403
1249
420
215410
33,5
2,98
4,67

605
825
232
7-100

669
927
232
7-100

3
435000

3
408000

24

24

3
103,0
46

3
102,6
46

Sound pressure:
Sound pressure in free field, at 10 m distance from
the external surface of the unit (in accordance with
UNI EN ISO 3744)

Dimensions (mm)
NSI12511801

NSI25022802

NSI32023602

NSI42035403

A
A

C
B

B
C

C
B
B

A
B
C

mm
mm
mm
kg

1251
2450
2200
3780
2979

1401
2450
2200
3780
3082

1601
2450
2200
3780
3252

1701
2450
2200
4770
3763

1801
2450
2200
4770
3956

2502
2450
2200
5750
5407

2802
2450
2200
5750
5562

3202
2450
2200
7160
6493

3402
2450
2200
9140
7464

3602
2450
2200
9140
7850

4203
2450
2200
10940
9194

4803
2450
2200
10940
9704

5103
2450
2200
13910
11155

5403
2450
2200
13910
11734

Cod.: snsiuy.03/ 1502

Mod. NSI
Height
Width
Lenght
Weight empty

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

275

TBX

Air/Water chillers for outdoor installation


With two-stage centrifugal compressor shell and tube heat exchangers and axial fans
Cooling capacity 259861kW

R134a
HIGH

SEASONAL
EFFICIENCY

Aermec
participates in the EUROVENT:
LCP programme, The products are listed on
the site www.eurovent-certification.com

Characteristics
Available in 13 sizes
Cooling only version
New generation two-stage oil-free centrifugal
compressor with magnetic levitation bearings
Refrigerant R134a
Exceptional high efficiency at part load (up to
30% higher ESEER compared to standard
chillers)
Electronic expansion valve for precise control
Flooded shell and tube evaporator optimised
for refrigerant R134a
Axial fans for extremely quiet operation
Compressor features:
1. Operates without oil as bearings are magnetic levitation type. Vibration free and very
quiet
2. Provided with inverter technology that per-

mits capacity modulation down to 25%


3. Integrated controller that reduces starting current to 6 A only
Standard and Low noise L Versions:
1. Operating limit up to 42 C external air temperature
2. Compressor acoustical enclosure for low
noise operation
3. Fan speed control
High efficiency A and High efficiency low
noise E Versions:
1. Operating limit up to 42 C external air temperature
2. Compressor acoustical enclosure for low
noise operation
3. EC (Electronically Commutated) fan
Modulating capacity control microprocessor

system
Evaporator trace heating.
LCD user interface: colour touch-screen with
simple and intuitive graphical menu
Multilingual display panel
Compact sizes
Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision AVX: Spring anti-vibration mounts. For com- Factory fitted.
systems with MODBUS protocol.
patibility of the AVX mounts refer to the tech- PTW: Remote control of the chiller operating
MULTICHILLER_TBX: Control system to
nical manual.
functions.
switch the individual chillers on and off, and GP: Protective grille. Condenser coil external
command them, in a system in which several
protection against accidental or hail damage.
units are installed in parallel, always ensuring
a constant delivery to the exchanger.

276

TBX

VERS.

1401

1801

2001

2302

2502

2652

2802

3202

3502

3702

3802

4102

Alls
Alls
Alls
L|E
L|E
L|E
L|E
L|E
L|E
L|E
L|E
|A
|A
|A
|A
|A
|A
|A
|A

L
A
E

AER485P1
AERWEB300
MULTICHILLER_TBX
GP300M
GP400M
GP500M
GP 300M+300M
GP 300M+400M
GP 400M+400M
GP 400M+500M
GP 500M+500M
GP 300M
GP 400M
GP 500M
GP 300M+300M
GP 300M+400M
GP 400M+400M
GP 400M+500M
GP 500M+500M
AVX

570
570
570
570

571
571
571
571

571
571
571
571

572
572
572
572

573
573
573
573

574
574
574
574

575
575
575
575

575
575
575
575

576
575
576
575

576
576
576
576

577
576
578
576

577
577
578
577

Note:
The number in brackets (x2) indicates the quantity to order.
AER485P1 - GP Accessory only factory fitted.

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Code:
TBX
Size:
1401, 1801, 2001, 2302, 2502, 2652, 2802, 3202, 3502, 3702,
3802, 4102, 4303
Model:
- Cooling only
Version:
- Standard
L - Standard low noise
A - High efficiency
E - High efficiency low noise
Condenser coil:
- Aluminium
R - Copper
S - Tinned copper
V - Anti-corrosion coated aluminium
Fan:
- Standard
I - EC (Electronically Commutated)
standard on A and E Versions
Power supply:
- 400V 3~ 50Hz with circuit breakers
Note:
Electronic expansion valve standard

277

Technical Data
Mod. TBX

1401
1801
2001
kW
287
368,3 407,3
kW
258,8 342,8 392,1
kW
286,8 370,7 415,5
kW
265,2 354,8 406,4
kW
91,8
117,2 129,3
kW
88,9
117,9 134,7
kW
86
110,9 124,8
kW
84,8
113,6 130,2
49536 63468 70176
l/h
l/h
44646 59065 67577
l/h
49536 63984 71724
l/h
45790 61229 70176
kPa
36
17
15
kPa
30
15
19
kPa
50
41
43
kPa
44
38
49
W/W
3,13
3,14
3,15
W/W
2,91
2,91
2,91
W/W
3,33
3,34
3,33
W/W
3,13
3,12
3,12
W/W
4,82
4,92
4,95
W/W
4,69
4,77
4,76
W/W
5,01
5,06
5,04
W/W
4,85
4,89
4,82
V/ph/Hz
A
147
195
216
A
144
198
225
A
134
179
200
A
132
176
209
A
153
234
240
A
153
234
240
A
159
242
250
A
159
242
250
A
24
30
36
A
24
30
36
A
30
38
46
A
30
38
46
A
A
30-100 30-100 30-100
type
n
1
1
1
type
n
1
1
1
|A
m3/h
94200 132800 166000
L|E
m3/h
69720 92960 116200
|L
type
A|E
type
|A
type
6
8
10
L|E
type
6
8
10
type
n
1
1
1
n/W
1/170
1/250
1/250

L
Cooling capacity
A
E

L
Total input power
A
E

L
Evaporator water flow rate
A
E

L
Evaporator pressure drop
A
E

L
EER
A
E

L
ESEER
A
E
Power supply

L
Total input current
A
E

L
Maximum input current
(FLA)
A
E

Maximum starting current L


(LRA)
A
E
Capacity modulation
Compressor
Refrigerant
Refrigerant circuit
Air flow rate

Fan

Evaporator
Electric heater
Maximum external air
temperature
Sound power

Sound pressure

|A
L
E
|A
L
E

2302
469,3
435,7
460,4
441,2
149
149,6
138,1
141,2
80840
75047
79464
76141
15
13
44
40
3,15
2,91
3,33
3,13
5,12
4,97
5,33
5,15

2502
509,2
463,9
502,2
473,6
161,4
159,3
150,4
152,2
87720
79911
86688
81755
15
15
44
46
3,16
2,91
3,34
3,11
5,14
4,97
5,35
5,13

2652
2802
3202
545,2 587,2 669,1
518,3 543,2
595
538,1 594,1 667,8
532,5
556
614
173
184,9 212,2
177,5 186,2 203,8
161,1 177,3 199,7
170,3
177
196,9
93912 101136 115240
89292 93568 102495
92880 102512 115240
91931 95976 105966
15
14
15
16
15
15
44
41
43
48
46
44
3,15
3,18
3,15
2,92
2,92
2,92
3,34
3,35
3,34
3,13
3,14
3,12
5,13
5,18
5,14
4,96
5,00
4,97
5,35
5,38
5,37
5,13
5,15
5,16
400V/3/50Hz
242
260
280
299
355
244
258
287
308
345
217
235
251
276
322
221
238
265
275
320
300
300
306
312
462
300
300
306
312
462
310
310
318
326
476
310
310
318
326
476
126
126
132
138
188
126
126
132
138
188
136
136
144
152
202
136
136
144
152
202
stepless
15-100 15-100 15-100 15-100 15-100
centrifugal inverter oil-free
2
2
2
2
2
R134a
1
1
1
1
1
166000 157000 199200 232400 232400
116200 109900 139440 162680 162680
axial
Axial EC (Electronically Commutated)
10
10
12
14
14
10
10
12
14
14
ooded shell & tube
1
1
1
1
1
1/250
1/250
1/250
1/250
1/250

3502
736
635,3
739,5
650,4
233,3
217,7
220,8
207,8
126764
109444
127624
112282
16
17
45
49
3,15
2,92
3,35
3,13
5,14
4,97
5,37
5,14

3702
780,9
687,8
793,3
707,4
247,4
236,3
237,3
226,5
134504
118477
136912
122106
17
16
46
47
3,16
2,91
3,34
3,12
5,14
4,98
5,36
5,15

3802
815,9
742,3
831,2
768,4
258,8
255
248,4
246,1
140524
127858
143448
132633
15
16
45
48
3,15
2,91
3,35
3,12
5,15
4,97
5,37
5,15

4102
844,8
784,6
861
813,1
268,2
269
258,1
260,1
145512
135154
148608
140352
16
17
48
48
3,15
2,92
3,34
3,13
5,14
4,96
5,34
5,14

389
366
355
337
468
462
484
476
194
188
210
202

412
396
382
366
474
468
492
484
200
194
218
210

431
426
399
396
480
474
500
492
206
200
226
218

447
449
413
417
480
480
500
500
206
206
226
226

15-100 15-100 15-100 15-100


2

1
1
1
1
265600 298800 332000 314000
153860 185920 209160 232400

16
14

18
16

20
18

20
20

1
1/250

1
1/250

1
1/250

1
1/250

42

42

42

42

42

42

42

42

42

42

42

42

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)

88
83
81
56
51
49

89
84
82
57
52
50

90
85
83
58
53
51

90
85
83
58
53
51

90
85
83
58
53
51

91
86
84
58
53
51

92
87
85
59
54
52

92
87
85
59
54
52

93
87
85
60
54
52

93
88
86
60
55
53

93
88
86
60
55
53

93
88
86
60
55
53

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure:
Measured in free field over a reflective plane (directivity factor Q = 2), at a distance of 10 metres from the outer surface of the unit, in accordance with ISO 3744.
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

278

Dimensions (mm)

Model. TBX
Height A
Width B

mm
mm
mm
mm

1401
2.450
2.200
3.780
3.780

1801
2.450
2.200
4.770
4.770

2001
2.450
2.200
5.750
5.750

2302
2.450
2.200
5.750
5.750

2502
2.450
2.200
5.750
5.750

2652
2.450
2.200
7.160
7.160

2802
2.450
2.200
8.150
8.150

3202
2.450
2.200
8.150
8.150

3502
2.450
2.200
9.140
8.150

3702
3802
4102
2.450 2.450 2.450
2.200 2.200 2.200
10.120 11.100 11.100
9.140 10.120 11.100

Cod.: STBXUY.06 / 1501

Length C

All
All
|A
L|E

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

279

NRP
0200/0750

Multipurpose
Air/Water for outdoor installation
Axial fans, scroll compressor
Cooling capacity 43184kW
Heating capacity 46206kW

R410A

DESIGNED FOR 2 AND 4-PIPE SYSTEMS


HIGH EFFICIENCY VERSION
HIGH EFFICIENCY EVEN AT PART LOAD
OPTION VERSION WITH BUILT-IN HYDRONIC KIT

Characteristics
NRP is the range of multipurpose external units
operating on refrigerant R410A, designed for 2
or 4-pipe systems. With just one unit simultaneous and independent requests for hot and
chilled water can be accommodated all year
round.
Version
NRP_A Multipurpose high efficiency version
NRP_E Multipurpose high efficiency low noise version
Operational limits (1)
- max. external air temperature 46C
Cooling mode
- Maximum leaving water temperature 55C
Heating mode
2refrigerant circuits
High efficiency scroll compressors with low
power input

with the possibility of selecting control of


Heat exchangers optimised to benefit from
the entering water temperature.
the excellent heat transfer characteristics of
- Condensing control in summer with a 0-10
R410A.
V modulating signal based on pressure and
flow switch as standard supply
compensated for external air temperature
Water filter
- Evaporating control in summer for heat
Options for integrated hydronic modules with
pump operation
pumps, buffer tank:
- Intelligent defrost control on drop of pressure
- Buffer tank and pumps or only pumps
- Automatic rotation of compressors and
- expansion tank
pumps based on operating hours
- Safety valve
- Load limiting safety control
- Pressure gauge
Metallic protective cabinet with anti-corro Axial fans for extremely quiet operation
sion polyester paint
Units fitted as standard with fan speed controller (DCPX), which permits operation in the
winter with external temperatures down to
10 C, and in heating mode with external
temperatures up to 42 C
Microprocessor controls.
- Control from the leaving water temperature,

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervising
network with integrated GPRS modem;
systems with MODBUS protocol.
AERWEB300-18G: Web server to monitor and
AERWEB300: The AERWEB option allows
remote control maximum 18 units on RS485
remote control of a chiller through a standnetwork with integrated GPRS modem.
ard PC and an ethernet connection with a MULTICHILLER_NRP: Control system to
standard browser; 4 versions available:
switch the individual chillers on and off, and
AERWEB300-6: Web server to monitor and
command them, in a system in which several
remote control maximum 6 units on RS485
units are installed in parallel, always ensuring
network;
a constant delivery to the exchanger.
AERWEB300-18: Web server to monitor and PGD1: Simplified remote panel. Allows conremote control maximum 18 units on RS485
trol of basic unit functions and alarm notificanetwork;
tion. Remote mounted up to 500 m away
AERWEB300-6G: Web server to monitor and
with TWISTED PAIR SCREENED cable and
remote control maximum 6 units on RS485
TCONN6J000.

280

GP: Protection grille protects the external


coil from accidental damage.
VT Anti-vibration mounts to be installed
under the base of the unit.
Accessories factory fitted only
DRE: Electronic soft starter which reduces
starting current by about 26%.
Available only with 400V power supply.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current.

Compatibility of accessories
Mod. NRP
AER485P1
AERWEB300
MULTICHILLER_NRP
PGD1
(1)
(1)

GP
VT (00-P1-P2-P3-P4)
VT (01-02-03-04-05-06-07-08-09-10)
VT (R1-R2-R3-R4)

Vers.
Alls
Alls
Alls
Alls
A
E
Alls
Alls
Alls

0200

3
17
13
17

0240

3
17
13
17

0280

3
17
13
17

0300

4
17
13
17

0330

4
17
13
17

0350

4
17
13
17

0500

2(x2)
2(x2)
13
10
13

0550

2(x2)
2(x2)
13
10
13

0600

2(x2)
2(x2)
13
10
13

0650

2(x2)
2(x2)
13
10
13

0700

2(x3)
2(x3)
22
22
22

0750

10(x3)
10(x3)
23
23
23

Alls
Alls

281
54

281
54

281
50

301
50

331
50

351
51

501
52

551
52

601
53

651
53

701
53

751
53

Accessories factory fitted only


DRE
RIF

(2)

(1) (x2)(x3) the number in brackets indicates the quantity to order


(2) Only available for 400V/3N/50Hz power supply

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

8
A
E
9
2
4
10

R
S
V
11

M
J
12

1
13-14
00
01
02
03
04
05
06
07
08
P1
P2
P3
P4
15-16
00
R1
R2
R3
R4

Code
NRP
Size
0200-0240-0280-0300-0330-0350-0500-0550-0600-0650-0700 (4)
Version
High efficiency
High efficiency in low noise operation
System type
2-pipe system (cooling + DHW heating)
4-pipe system (cooling + heating)
Coil
In aluminium
In copper
In tinned copper
Coated aluminium (epoxy paint)
Fans (5)
Standard
Increased
High static pressure Inverter
Power supply (6)
400V/3N/50Hz with circuit breakers
220V/3/50Hz with circuit breakers
System integrated hydronic module (7)
without pumps or buffer tank
n1 low head pump and buffer tank
n2 low head pump and buffer tank
n1 high head pump and buffer tank
n2 high head pump and buffer tank
n1 low head pump and buffer tank (with holes for immersion heaters)
n2 low head pump and buffer tank (with holes for immersion heaters)
n1 low high pump and buffer tank (with holes for immersion heaters)
n2 low high pump and buffer tank (with holes for immersion heaters)
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump
Heat recovery integrated hydronic module
without pumps
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump

CONFIGURATION POSSIBILITY BETWEEN


HYDRONIC MODULES
FOR NRP 0200 0750
Heat recovery integrated hydronic module

System integrated hydronic module

Field
1,2,3
4,5,6,7

00
01
02
03
04
05
06
07
08
P1
P2
P3
P4

00
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok

R1
ok
nd
nd
nd
nd
nd
nd
nd
nd
ok
ok
ok
ok

R2
ok
nd
nd
nd
nd
nd
nd
nd
nd
ok
ok
ok
ok

R3
ok
nd
nd
nd
nd
nd
nd
nd
nd
ok
ok
ok
ok

R4
ok
nd
nd
nd
nd
nd
nd
nd
nd
ok
ok
ok
ok

nd

(4) The size 0200-0240-0280-0300-0330-0350 only available in low noise version "E"
(5) Standard on/off fans for sizes from 0500 to 0750
Increased on/off fans, option available for sizes from 0200 to 0350
Standard Inverter fans for sizes from 0200 to 0350, without useful static pressure
Inverter fan, option for sizes from 0500 to 0750 with useful static pressure
(6) 220V/3/50Hz is not available for size 0750
(7) Buffer tanks with holes for additional heaters are supplied from factory with plastics caps of protection, before system's loading, where the installation of one or all the
heaters is not provided, it is mandatory to replace plastic caps with special caps, which are commonly available in the market.

281

Technical Data
0200

Mod. NRP Multipurpose for 2-pipe system


Cooling system side

0330

0350

0500

0550

0600

0650

0700

0750

100
95
32,47
35,23
3,07
2,68
17200
16340
37
34

103
99
36,00
38,95
2,87
2,53
17900
17030
39
35

123
116
44,15
48,37
2,80
2,39
21300
19874
37
32

140
130
50,51
55,51
2,78
2,35
24252
22530
48
41

159
152
55,16
61,88
2,88
2,46
27520
26300
56
51

184
178
64,58
70,60
2,85
2,52
31800
30867
67
63

43
50
56
64
68
80
14,01 16,59 18,92 20,89 23,25 27,06
3,05 3,00 2,95 3,05 2,91 2,94
7400 8600 9630 11000 11700 13770
26
37
22
29
22
31

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

46
53
60
75
80
84
107
113
138
153
174
206
13,34 15,63 17,76 22,41 23,96 25,70 32,64 35,08 41,26 45,72 53,80 62,81
3,47 3,41 3,39 3,37 3,35 3,28 3,26 3,21 3,34 3,34 3,23 3,29
7912 9116 10300 12900 13760 14448 18232 19270 23564 26144 29756 35260
30
42
25
40
31
34
42
45
45
56
65
83

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

46
53
60
75
80
84
106
112
138
153
174
206
13,24 15,48 17,73 22,36 24,01 25,57 32,54 34,98 41,33 45,66 53,46 62,35
3,49 3,44 3,40 3,37 3,35 3,30 3,27 3,22 3,33 3,35 3,25 3,30
7912 9116 10300 12900 13760 14448 18232 19264 23564 26146 29756 35260
13
17
21
33
38
19
31
34
51
49
35
50

A/E
A/E
A/E
A/E
A/E
A/E
A/E
(1) A/E

kW
kW
kW
l/h
kPa
l/h
kPa
W/W

46
52
58
69
74
87
103
111
134
148
169
203
58
67
75
88
95
111
132
143
175
194
219
262
13,45 15,82 18,10 20,85 22,90 25,90 31,18 33,37 43,87 48,58 53,03 64,06
7852 9040 10040 11868 12745 15000 17800 19195 23070 25598 29163 34925
29
41
24
33
26
36
40
44
42
52
62
81
9976 11520 12900 15136 16340 19092 22704 24424 29928 33196 37496 44892
20
27
33
46
54
33
47
55
82
78
56
81
7,72 7,58 7,39 7,55 7,41 7,67 7,57 7,62 7,05 7,06 7,33 7,27

EER
Water flow rate
Total pressure drop

0200

Mod. NRP Multipurpose for 4-pipe system


Cooling system side
Cooling capacity
Total input power
EER
Water flow rate
Total pressure drop

(1)

0240

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

123
116
44,15
48,37
2,80
2,39
21300
19874
37
32

140
130
50,51
55,51
2,78
2,35
24252
22530
48
41

159
152
55,16
61,88
2,88
2,46
27520
26300
56
51

184
178
64,58
70,60
2,85
2,52
31800
30867
67
63

A
E
A
E
A
E
A
E
A
E

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

100
103
43
50
56
64
68
80
95
99
32,47 36,00
14,01 16,59 18,92 20,89 23,25 27,06 35,23 38,95
3,07 2,87
3,05 3,00 2,95 3,05 2,91 2,94 2,68 2,53
17200 17900
7400 8600 9630 11000 11700 13770 16340 17030
37
39
26
37
22
29
22
31
34
35

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

46
53
60
75
80
84
107
113
138
153
174
206
13,24 15,48 17,73 22,36 24,01 25,57 32,54 34,98 41,33 45,66 53,46 62,35
3,49 3,44 3,39 3,37 3,35 3,28 3,26 3,21 3,34 3,34 3,23 3,29
7912 9116 10300 12900 13760 14448 18232 19264 23564 26146 29756 35260
13
17
21
33
38
19
31
34
51
49
35
50

A/E
A/E
A/E
A/E
A/E
A/E
A/E
A/E

kW
kW
kW
l/h
kPa
l/h
kPa
W/W

46
52
58
69
74
58
67
75
88
95
13,45 15,82 18,10 20,85 22,90
7852 9040 10040 11868 12745
29
41
24
33
26
9976 11520 12900 15136 16340
20
27
33
46
54
7,72 7,58 7,39 7,55 7,41

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
Cooling mode with heat recovery:
heat recovery water temperature (in/out) 40C/45C; Evaporator water temperature (out) 7C
(1) Total Efciency Ratio

282

0300

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

Total input power

Heating system side


Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Cooling wit heat recovery
Cooling capacity
Recovered power
Total input power
Water flow rate (cold side)
Total pressure drop (cold side)
Water flow rate (hot side)
Total pressure drop (hot side)
TER

0280

A
E
A
E
A
E
A
E
A
E

Cooling capacity

Heating system side


Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Heating DHW side
Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Cooling with heat recovery
Cooling capacity
Recovered power
Total input power
Water flow rate (system side)
Total pressure drop (system side)
Water flow rate (DHW side)
Total pressure drop (DHW side)
TER

0240

87
111
25,90
15000
36
19092
33
7,67

103
132
31,18
17800
40
22704
47
7,57

111
143
33,37
19195
44
24424
55
7,62

134
175
43,87
23070
42
29928
82
7,05

148
194
48,58
25598
52
33196
78
7,06

169
219
53,03
29163
62
37496
56
7,33

203
262
64,06
34925
81
44892
81
7,27

Technical Data
0200

0240

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

A
A
A
A

28
36
119

33
41
150

38
46
155

41
53
184

45
58
190

52
63
200

55
60
76
214

59
64
81
220

72
79
100
232

82
91
112
243

88
99
122
261

113
120
144
320

type
n
n
%

scroll
2
2

scroll
2
2

scroll
2
2

scroll
2
2

scroll
2
2

scroll
2
2

scroll
3
2

scroll
3
2

scroll
4
2

scroll
4
2

scroll
4
2

scroll
4
2

GENERAL DATA
Electrical data
(1)
(1)
(1)
(1)

Total input current


Maximum current (FLA)
Starting current (LRA)

A
E
A/E
A/E

Compressors

Compressors

Circuits
0/50/100
0/50/100
0/50/100
0/50/100
0/50/100
0/50/100
0/50/100
0/50/100
0/50/100 0/25/50/100 0/25/50/100
Capacity control
R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Exchanger side (hot/cold) 2 pipe system / side (cold) 4 pipe system
type
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
Exchanger
n
1
1
1
1
1
1
1
1
1
1
1
21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2
hydraulic connections
(in/out)

Exchanger side (DHW) 2 pipe system / side (hot) 4 pipe system


type
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
Exchanger
n
1
1
1
1
1
1
1
1
1
1
1
hydraulic connections
(in/out)

21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2
Fans standard
type
axial
axial
axial
axial
axial
axial
axial
axial
axial
axial
axial
Fans
n
6
6
6
8
8
8
2
2
2
2
3
37000 37000 36500 36500 58000
A
m3/h
Air flow rate
cooling mode
E
m3/h 20000 20000 20000 26000 26000 26000 20200 21100 21400 22400 31900
Air flow rate heating mode
m3/h 20000 20000 20000 26000 26000 26000 37000 37000 36500 36500 58000
System integrated hydronic module
Buffer tank
l.
300
300
300
300
300
300
500
500
500
500
500
For more information, refer to the selection program or the technical documentation available
Useful head
kPa
Soud data
dB(A)
(2)
A
50
50
50
51
53
Sound pressure
dB(A)
(2)
E
42
42
42
43
43
44
42
42
42
43
45
dB(A)
(2)
A
82
82
82
83
85
Sound power
dB(A)
(2)
E
74
74
74
75
75
76
74
74
74
75
77
V/ph/Hz 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N 400V/3N
Power supply

0/25/50/100

R410A
plate
1
3
plate
1
3
axial
3
48000
34600
48000
700

53
45
85
77
400V/3N

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
(1) The electrical data of the versions without hydronic module integrated
(2) Calculated in cooling mode
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
NRP 0200 0280

NRP 0300 0350

A
A
C
B

NRP 0500 0650

NRP 0700 0750

Mod. NRP
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
All
All
All

0200
1606
1100
2700
788

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

0240
1606
1100
2700
790

0280
1606
1100
2700
792

0300
1606
1100
3200
862

0330
1606
1100
3200
872

0350
1606
1100
3200
894

0500
1875
1100
3342
1233

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

0550
1875
1100
3342
1237

0600
1875
1100
3342
1359

0650
1875
1100
3342
1378

0700
1875
1100
4342
1591

0750
1975
1500
4350
1939

283

Cod.: SNRP0200-0750UY.04 /1502

NRP
0800/1800

R410A
R410A

Multipurpose
Air/Water for outdoor installation
Axial fans, scroll compressor
Cooling capacity199475kW
Heating capacity 242547kW

DESIGNED FOR 2 AND 4-PIPE SYSTEMS


HIGH EFFICIENCY VERSION
HIGH EFFICIENCY EVEN AT PART LOAD
OPTION VERSION WITH BUILT-IN HYDRONIC KIT

Characteristics
NRP is the range of multipurpose external units
operating on refrigerant R410A, designed for 2
or 4-pipe systems. With just one unit simultaneous and independent requests for hot and
chilled water can be accommodated all year
round.
Version
NRP_A Multipurpose high efficiency version
NRP_E Multipurpose high efficiency low noise version
Operational limits (1)
- max. external air temperature 46C
Cooling mode
- Maximum leaving water temperature 55C
Heating mode
2refrigerant circuits

Heat exchangers optimised to benefit from Microprocessor controls.


the excellent heat transfer characteristics of
- Control from the leaving water temperature,
R410A.
with the possibility of selecting control of
flow switch as standard supply
the entering water temperature.
- Condensing control in summer with a 0-10
Water filter
V modulating signal based on pressure and
Options for integrated hydronic modules with
compensated for external air temperature
pumps:
- Evaporating control in summer for heat
- Pumps or only pumps
pump operation
- expansion tank
- Intelligent defrost control on drop of pressure
- Safety valve
- Automatic rotation of compressors and
- Pressure gauge
pumps based on operating hours
Axial fans for extremely quiet operation
- Load limiting safety control
Units fitted as standard with fan speed controller (DCPX), which permits operation in the Metallic protective cabinet with anti-corrosion polyester paint
winter with external temperatures down to
10 C, and in heating mode with external
temperatures up to 42 C

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: The AERWEB option allows
remote control of a chiller through a standard PC and an ethernet connection with a
standard browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control maximum 6 units on RS485
network;
AERWEB300-18: Web server to monitor and
remote control maximum 18 units on RS485
network;
AERWEB300-6G: Web server to monitor and
remote control maximum 6 units on RS485
network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and
remote control maximum 18 units on RS485

284

network with integrated GPRS modem.


Accessories factory fitted only
MULTICHILLER_NRP: Control system to
DRE: Electronic soft starter which reduces
switch the individual chillers on and off, and
starting current by about 26%.
command them, in a system in which several
Available only with 400V power supply.
units are installed in parallel, always ensuring RIF: Power factor correction. Connected in
a constant delivery to the exchanger.
parallel to the motor allowing about 10%
PGD1: Simplified remote panel. Allows conreduction of input current.
trol of basic unit functions and alarm notification. Remote mounted up to 500 m away
with TWISTED PAIR SCREENED cable and
TCONN6J000.
GP: Protection grille protects the external
coil from accidental damage.
AVX Anti-vibration mounts to be installed
under the base of the unit.

Compatibility of accessories
Mod. NRP
AER485P1
AERWEB300
MULTICHILLER_NRP
PGD1
GP
AVX (00)
AVX (P1-P2-P3-P4)
AVX (P1-R1P4-R4)

Vers.
Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls

0800

GP260
704
706
706

0900

GP260
710
712
712

1000

GP260
716
712
712

1250

GP350
719
721
721

1404

GP350
725
727
727

1504

GP350
730
732
732

1655

GP500
734
736
736

1800

GP500
737
736
736

Alls
Alls

801
88

901
90

1001
92

1251
92

1404
92

1504
92

1655
93

1801
94

Accessories factory fitted only


DRE
RIF

(1)

(1) Only available for 400V/3/50Hz power supply

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

8
A
E
9
2
4
10

R
S
V
11

J
12

13-14
00
P1
P2
P3
P4
15-16
00
R1
R2
R3
R4

Code
NRP
Size
0800-0900-1000-1250-1404-1504-1655-1800
Version
High efficiency
High efficiency in low noise operation
System type
2-pipe system (cooling + DHW heating)
4-pipe system (cooling + heating)
Coil
In aluminium
In copper
In tinned copper
Coated aluminium (epoxy paint)
Fans
Standard
High static pressure Inverter
Power supply
400V/3/50Hz with circuit breakers
System integrated hydronic module
without pumps
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump
Heat recovery integrated hydronic module
without pumps
n1 low head pump
n2 low head pump
n1 high head pump
n2 high head pump

NRP 0800 1000

NRP

System integrated
hydronic module

Heat recovery integrated hydronic module

R1

R2

R3

R4

ok

ok

n.d.

ok

n.d.

P1

ok

ok

n.d.

ok

n.d.

P2

ok

ok

n.d.

ok

n.d.

P3

ok

ok

n.d.

ok

n.d.

P4

ok

ok

n.d.

ok

n.d.

NRP 1250 1800

NRP

System integrated
hydronic module

Field
1,2,3
4,5,6,7

Heat recovery integrated hydronic module

R1
R2
R3
R4

ok

ok

ok

ok

ok

P1

ok

ok

ok

ok

ok

P2

ok

ok

ok

ok

ok

P3

ok

ok

ok

ok

ok

P4

ok

ok

ok

ok

ok

nd

285

Technical Data
Mod. NRP Multipurpose for 2-pipe system
Cooling system side
Cooling capacity
Total input power
EER
Water flow rate
Total pressure drop
Heating system side
Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Heating DHW side
Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Cooling with heat recovery
Cooling capacity
Recovered power
Total input power
Water flow rate (system side)
Total pressure drop (system side)
Water flow rate (DHW side)
Total pressure drop (DHW side)
TER

(1)

Total input power


EER
Water flow rate
Total pressure drop
Heating system side
Heating capacity
Total input power
COP
Water flow rate
Total pressure drop
Cooling with heat recovery
Cooling capacity
Recovered power
Total input power
Water flow rate (cold side)
Total pressure drop (cold side)
Water flow rate (hot side)
Total pressure drop (hot side)
TER

(1)

0900

1000

1250

1404

1504

1655

1800

A
E
A
E
A
E
A
E
A
E

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

217
199
73,52
81,23
2,95
2,45
37498
34477
59
50

242
216
83,41
95,24
2,90
2,27
41796
37289
58
47

259
229
89,40
101,32
2,89
2,26
44753
39609
54
43

321
290
109,36
121,82
2,94
2,38
55556
50044
64
54

363
331
122,55
135,62
2,97
2,44
62852
57122
52
43

400
367
136,71
150,55
2,93
2,44
69171
63288
53
44

439
400
147,20
163,11
2,98
2,46
75888
69115
55
46

475
428
157,93
176,67
3,01
2,42
81966
73977
55
45

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

242
74,65
3,25
41452
72

259
81,11
3,20
44312
66

292
89,40
3,26
49946
68

387
117,15
3,30
66115
93

402
121,47
3,31
68833
63

461
139,96
3,30
78870
68

506
155,68
3,25
86579
72

547
167,47
3,27
93555
72

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

242
74,26
3,26
41452
50

259
80,71
3,21
44312
44

291
89,01
3,27
49946
49

385
116,04
3,32
66048
49

401
120,95
3,32
68833
44

460
139,45
3,30
78870
51

505
155,00
3,26
86579
51

546
166,80
3,27
93555
53

A/E
A/E
A/E
A/E
A/E
A/E
A/E
A/E

kW
kW
kW
l/h
kPa
l/h
kPa
W/W

226
291
68,92
38924
63
49708
72
7,50

254
330
80,24
43834
64
56417
72
7,29

282
366
89,65
48556
63
62609
78
7,23

339
434
102,00
58291
70
74305
63
7,58

384
493
116,23
66151
57
84453
66
7,55

428
552
132,97
73685
60
94601
73
7,38

470
601
140,38
80797
62
102857
72
7,63

503
645
151,76
86568
61
110425
74
7,57

0800

0900

1000

1250

1404

1504

1655

1800

Mod. NRP Multipurpose for 4-pipe system


Cooling system side
Cooling capacity

0800

A
E
A
E
A
E
A
E
A
E

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

217
199
73,52
81,23
2,95
2,45
37498
34477
59
50

242
216
83,41
95,24
2,90
2,27
41796
37289
58
47

259
229
89,40
101,32
2,89
2,26
44753
39609
54
43

321
290
109,36
121,82
2,94
2,38
55556
50044
64
54

363
331
122,55
135,62
2,97
2,44
62852
57122
52
43

400
367
136,71
150,55
2,93
2,44
69171
63288
53
44

439
400
147,20
163,11
2,98
2,46
75888
69115
55
46

475
428
157,93
176,67
3,01
2,42
81966
73977
55
45

A/E
A/E
A/E
A/E
A/E

kW
kW
W/W
l/h
kPa

242
74,26
3,26
41452
50

259
80,71
3,21
44312
44

291
89,01
3,27
49946
49

385
116,04
3,32
66048
49

401
120,95
3,32
68833
44

460
139,45
3,30
78870
51

505
155,00
3,26
86579
51

546
166,80
3,27
93555
53

A/E
A/E
A/E
A/E
A/E
A/E
A/E
A/E

kW
kW
kW
l/h
kPa
l/h
kPa
W/W

226
291
68,92
38924
63
49708
72
7,50

254
330
80,24
43834
64
56417
72
7,29

282
366
89,65
48556
63
62609
78
7,23

339
434
102,00
58291
70
74305
63
7,58

384
493
116,23
66151
57
84453
66
7,55

428
552
132,97
73685
60
94601
73
7,38

470
601
140,38
80797
62
102857
72
7,63

503
645
151,76
86568
61
110425
74
7,57

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; External air temperature 7C b.s./6C b.u.
Cooling mode with heat recovery:
heat recovery water temperature (in/out) 40C/45C; Evaporator water temperature (out) 7C
(1) Total Efciency Ratio

286

Technical Data
0800

0900

1000

1250

1404

1504

1655

1800

A
A
A
A

136
145
173
348

158
169
195
404

180
192
217
426

196
211
267
535

235
251
296
505

273
292
325
534

289
306
365
633

304
324
398
666

type
n
n
%

scroll
4
2

scroll
4
2

scroll
4
2

scroll
4
2

scroll
4
2

scroll
4
2

scroll
5
2

scroll
6
2

GENERAL DATA
Electrical data
A
E
A/E
A/E

(1)
(1)
(1)
(1)

Total input current


Maximum current (FLA)
Starting current (LRA)
Compressors

Compressors

Circuits
Capacity control
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Refrigerant
Exchanger side (hot/cold) 2 pipe system / side (cold) 4 pipe system
type
plate
plate
plate
plate
plate
plate
plate
plate
Exchanger
n
1
1
1
1
1
1
1
1
3"
3"
3"
4"
4"
4"
4"
4"
hydraulic connections
(in/out)

Exchanger side (DHW) 2 pipe system / side (hot) 4 pipe system


type
plate
plate
plate
plate
plate
plate
plate
plate
Exchanger
n
1
1
1
1
1
1
1
1
hydraulic connections
(in/out)

3"
3"
3"
4"
4"
4"
4"
4"
Fans standard
type
axial
axial
axial
axial
axial
axial
axial
axial
Fans
n
4
4
4
6
6
6
8
8
85600
84600
83600
126000
124200
122400
168000
165600
A
m3/h
Air flow rate
cooling mode
E
m3/h
59920
59220
60610
88200
90000
91800
117600
115920
Air flow rate heating mode
m3/h
85600
84600
83600
126000
124200
122400
168000
165600
System integrated hydronic module
For more information, refer to the selection program or the technical documentation
Useful head
kPa
Sound data
dB(A)
(2)
A
56,5
56,5
56,5
59,5
59
58,5
60
62
Sound pressure
dB(A)
(2)
E
51
51
51
54
53,5
53
54,5
56,5
dB(A)
88,5
88,5
88,5
91,5
91
91,5
92
94
(2)
A
Sound power
dB(A)
(2)
E
83
83
83,5
86
85,5
85
86,5
88,5
V/ph/Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Power supply

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
(1) The electrical data of the versions without hydronic module integrated
(2) Calculated in cooling mode
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)
NRP0800-1000

NRP1250-1504

NRP1655-1800

Mod. NRP
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
Alls
Alls
Alls

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

0800
2450
2200
3400
2270

0900
2450
2200
3400
2460

1000
2450
2200
3400
2640

1250
2450
2200
4250
2970

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

1404
2450
2200
4250
3220

1504
2450
2200
4250
3430

1655
2450
2200
5750
3950

1800
2450
2200
5750
4090

287

Cod.: SNRP0800-1800UY.04 / 1501

NRL

Air/Water chillers for outdoor installation with free cooling


Scroll compressors, plate exchangers and axial fans
Cooling capacity from kW59194

0280/0750
free-cooling

R410A

HIGH EFFICIENCY VERSION


HIGH EFFICIENCY ALSO AT PARTIAL LOADS
SYSTEM SIDE INTEGRATED HYDRONIC KIT OPTION
Features
The NRL free cooling are chillers, designed and
manufactured to meet air conditioning requirements in residential/commercial buildings or to
meet refrigeration requirements in industrial facilities.
They are outdoor units with scroll compressors,
axial fans, external copper coils with aluminium
fins and plate exchanger.
These chillers are also equipped with a Free cooling coil and are used when the refrigerant load
request persists even during the winter months, or
when the outdoor air temperature is below the
temperature of the return liquid from the system.
In Free cooling operation (mixed Free cooling and
compressors, or Free cooling only), the fluid is
cooled directly by the outdoor air, allowing even
the complete shutdown of compressors with a
significant energy saving. It is also possible to
have the Glycol free version for all those applications where the use of glycol is not allowed
Versions
NRL_FA High efficiency
NRL_FE Silenced
NRL_BA High efficiency without the use of glycol
NRL_BE Silenced without the use of glycol

Operating range: Work up to 44C of outdoor


air temperature at full load. For further details
refer to the selection software/technical documentation.
Unit with two refrigerant circuits designed to
provide maximum efficiency at full load,
ensuring high efficiency at partial loads also
and ensuring continuity in case one of the
two circuits stop.
Flow switch, water filter and standard high
and low pressure transducers
Possibility of integrated hydronic kit that
encloses the main hydraulic components; it is
available in different configurations with or
without storage, one or two high static pressure pumps
Three-way valve located on the water side for
water switching on the Free-Cooling coils
Device for electronically controlling the
series condensation, for operation even at
low temperatures or in free cooling, which
allows adjusting the air flow rate to actual
system demand with resulting advantages in
terms of consumption reduction.

Microprocessor adjustment, that allows iso-

lating the condenser coils to maximise the


free cooling efficiency, even in mixed Free
cooling and compressor operation
Complete, with keyboard and LCD display,
for easy consultation and intervention on the
unit via a menu available in several languages.
The presence of a programmable timer allows
setting time bands of operation and a possible
second set-point
The temperature control takes place with the
integral proportional logic, based on the
water output temperature.
Night Mode: it is possible to set a silenced
operation profile.
Perfect for night operation, since it guarantees
greater acoustic comfort in the evenings, and
a high efficiency in the time of greater load.

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol.
PGD1: Simplified remote panel. Allows performing
the basic controls of the unit with alarm signals.
MULTICHILLER_PCO: Control, switch-on and
switch-off system of the single chillers where multiple units are installed in parallel, always ensuring
constant ow rate to the exchangers.
AERWEB300: the AERWEB device allows the

remote control of a chiller by means of a common

PC through Ethernet connection, via a common


browser; 4 models available:
AERWEB300-6: Web server for monitoring and
controlling maximum 6 RS485 network devices;

288

AERWEB300-18: Web server for monitoring and Accessories mounted in the factory;
controlling maximum 18 RS485 network devices;
DRE: Peak current reduction electronic device.
AERWEB300-6G: Web server for monitoring and
Only available with 400V power supply.
controlling maximum 6 RS485 network devices
RIF: power factor correction, connected in parallel
with integrated GPRS modem;
to the motor, it allows a reduction of the input
AERWEB300-18G: Web server for monitoring and
current (approx. 10%).
controlling maximum 18 RS485 network devices
PRM1: Manually-rearmed pressure switch, wired
with integrated GPRS modem;
in series to the high pressure switch on the ow
pipe of the compressor.
GP: Protection grids for coils and cooling circuit.
VT: Group of anti-vibration mounts.

Accessories compatibility
Mod. NRL
AER485P1
PGD1
MULTICHILLER_PCO
AERWEB300
GP
VT

Vers.

All
(1)
All
(00-P3-P4)
(03-04)

0280

0300

0330

0350

0500

0550

0600

0650

0700

0750

4
17
13

4
17
13

4
17
13

4
17
13

2(x2)
13
10

2(x2)
13
10

2(x3)
22
22

2(x3)
22
22

2(x3)
22
22

10 (x3)
23
23

281
50

301
50

331
50

351
51

501
52

551
52

601
53

651
53

701
53

Accessories mounted in the factory;


DRE
REF
PRM1

400V/3N
All
All

751
53

(1) (x2)(x3) indicates the number of kit to order

Choosing the unit


By appropriately combining the variety of options available, every model can be configured in order to meet all specific system requirements.

Field
Description
1,2,3
NRL
4,5,6,7 Sizes
0280-0300-0330-0350-0500-0550-0600-0650-0700-0750 (2)
8
Scope of application
Standard (temperature of water produced up to +4 C)
Y Low temperature (temperature of water produced from +4C to -8C)
X Electronic thermostatic valve (temperature of water produced up to +4 C) for different temperatures, contact the
supplier
9
Model
F Chiller with Free cooling
K Chiller with Free cooling and low pressure drops
B Chiller with Free cooling glycol free
10
Heat recovery
Without heat recovery
11
Version
A High efficiency
E Silenced high efficiency
12
Coils
Aluminium
R Copper
S Tinned copper
V Painted
13
Fans (3)
Standard
M Icreased
J Inverter
14
Power supply
400V/3N/50Hz with magnet circuit breakers
1 220V/3/50Hz with magnet circuit breakers
15-16 System side integrated hydronic kit (4)
00 Without hydronic kit
03 Storage tank with 1 high static pressure pump
04 Storage tank with 2 high static pressure pumps
P3 1 High static pressure pump
P4 2 High static pressure pumps
(2) Sizes 0280-0300-0330-0350 are only silenced E and are standard fitted with Inverter fans
(3) Standard on/off fans for sizes from 0500 to 0750
Increased on/off fans, option available for sizes from 0280 to 0650
Standard Inverter fans for sizes from 0280 to 0350, without useful static pressure
Inverter fan, option for sizes from 0500 to 0750 with useful static pressure
(4) the system side hydronic kit option is not available for the freecooling glycol free "B" models

289

Technical data
Freecooling Models
Cooling capacity
Input power
EER
Water flow rate
Total pressure drops
Cooling capacity
Input power
EER
Water flow rate
Total pressure drops

FA
FE
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA/FE
FA/FE
FA
FE
FA
FE

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
W/W
l/h
l/h
kPa
kPa

0280
59
18.1
3.26
10150
63
58.0
1.05
55.24
9539
85

0300
65
21.8
2.98
11180
53
68.0
1.05
64.76
10509
61

0330
74
24.0
3.08
12730
66
83.0
1.35
61.48
11964
76

0350
82
28.3
2.90
14100
58
85.0
1.35
62.96
13258
73

0500
99
91
33.7
37.0
2.93
2.46
17030
15650
60
51
103.0
2.65
38.87
16006
14713
70
59

0550
104
95
37.3
40.0
2.79
2.37
17890
16340
69
58
104.0
2.65
39.25
16815
15360
80
66

0600
132
119
44.5
49.2
2.96
2.42
22700
20470
78
63
137.0
3.9
35.13
21342
19240
95
78

0650
144
130
51.7
59.8
2.79
2.17
24770
22360
73
60
159.0
3.9
40.77
23282
21018
95
77

0700
159
147
60.8
65.8
2.62
2.23
27350
25280
87
74
174.0
5.4
32.22
25707
23767
110
94

0750
191
177
69.6
76.4
2.75
2.32
32850
30440
103
89
187
5.4
34.63
32850
30440
156
134

0300
52
1.85
28.11
11180
53

0330
64
2.35
27.23
12730
66

0350
66
2.35
28.09
14100
58

0500
79
3.65
21.64
17030
15650
60
51

0550
80
3.65
21.92
17890
16340
69
58

0600
104
5.2
20.00
22700
20470
78
63

0650
122
5.7
21.40
24770
22360
73
60

0700
133
7.7
17.27
27350
25280
87
74

0750
143
7.7
18.57
32850
30440
103
89

0300
66
21.8
3.04
11404
41
66
1.05
62.8
10720
45

0330
76
24
3.15
12983
36
81
1.35
59.6
12207
44

0350
84
28.3
2.96
14386
43
83
1.35
61.1
13516
53

0500
101
93
33.7
37
3
2.51
17369
15965
44
38
98
2.65
37
16330
15000
50
42

0550
106
97
37.3
40
2.84
2.42
18246
16667
37
31
99
2.65
37.3
17154
15667
44
37

0600
135
121
44.5
49.2
3.03
2.47
23158
20878
42
34
121
3.9
31.1
21762
19628
51
42

0650
147
133
51.7
59.8
2.84
2.22
25264
22807
40
33
139
3.9
35.7
23751
21439
51
42

0700
162
150
60.8
65.8
2.67
2.28
27895
25790
49
42
153
5.4
28.2
26224
24236
62
53

0750
194
180
69.6
76.4
2.80
2.36
33509
31053
34
30
165
5.4
30.6
32169
29811
64
55

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Cooling in freecooling (100%)
Evaporator water temperature (in) 15 C; Outdoor air temperature 2C

Freecooling glycol free models


Cooling capacity
(1)
Input power
EER
Water flow rate
Total pressure drops

BA/BE
BA/BE
BA/BE
BA
BE
BA/BE
BE

kW
kW
W/W
l/h
l/h
kPa
kPa

0280
45
1.85
24.32
10150
63

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C
(1) Performance in cooling, operation as chiller, are the same

Freecooling with low pressure loads models


KA
Cooling capacity
KE
KA
Input power
KE
KA
EER
KE
KA
Water flow rate
KE
KA
Total pressure drops
KE
Cooling capacity
KA/KE
Input power
KA/KE
EER
KA/KE
KA
Water flow rate
KE
KA
Total pressure drops
KE

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
W/W
l/h
l/h
kPa
kPa

0280
60
18.1
3.32
10351
34
56
1.05
53.6
9733
43

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Cooling in freecooling (100%)
Evaporator water temperature (in) 15 C; Outdoor air temperature 2C

290

Technical data
GENERAL DATA
Electrical data
Total input current (Chiller)

Total input current (freecooling)

(2)
FA
(2)
FE
(2) FA/FE
(2) BA/BE
(2) KA/KE

A
A
A
A
A

Maximum current (FLA)


Peak current (LRA)
Compressors

A
type
n
n
type

Compressors
Circuits
Refrigerant gas
System side heat exchanger

type
n
(in/out)

Heat exchanger
Hydraulic connections
Standard Fans
fans

A
E
A
E

Air flow rate in cooling mode


System side integrated hydronic kit
Storage tank
Useful static pressure
Sound data

0300

0330

0350

0500

0550

0600

0650

0700

0750

32
4.6
8.1
4.6
46
155

38
4.6
8.1
4.6
53
184

41
5.9
10.3
5.9
58
190

51
5.9
10.3
5.9
63
200

61
67
5.9
8.1
5.9
76
214

65
70
5.9
8.1
5.9
81
220

79
87
8.7
11.6
8.7
100
232

84
97
8.7
12.7
8.7
112
243

101
109
11.6
16.5
11.6
122
261

123
135
11.6
16.5
11.6
144
320

2
2

2
2

2
2

2
2

3
2

3
2

4
2

4
2

4
2

4
2

1
2"

1
2"

1
2"

1
2"

1
2"

2
2
50000
33500

2
2
49000
35300

3
3
56000
47600

3
3
56000
46500

300

300

300

700

scroll

R410A
plates
1
2"

1
2"

1
2"

1
2"

1
2"

6
20000

6
19000

8
25000

8
25000

300

300

300

300

axial
2
2
2
2
32500
32500
23400
24100

(3)
l
A kPa

Sound power
Sound Pressure
Electric power supply

type
no.
no.
m3/h
m3/h

0280

(4)

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

300

300

refer to the selection program or to the technical documentation


74
42

74
42

75
43

76
44

82
82
76
76
50
50
44
44
400V/3N/50Hz

83
76
51
44

84
77
52
45

85
77
53
45

87
82
55
50

(2) The electric data is of the versions without integrated hydronic kit
(3) the system side hydronic kit option is not available for the freecooling glycol free "B" models
(4) 0750 = 400V/3/50Hz
Sound power
Aermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested by Eurovent certification.
Sound Pressure
Sound pressure measured in free field, 10 m away from the unit external surface (in compliance with UNI EN ISO 3744).
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

Dimension and weight data


NRL 0280-0300

NRL 0330-0350

NRL 0500-0550-0600-0650

NRL 0700-0750

A
A

C
B

C
B

Mod. NRL
Height
Width

A
B

U.M.
(mm)
(mm)

Length

(mm)

Loadless weight

(kg)

Vers.

A/E 00
FA/FE
BA/BE
-

0280
1606
1100

0300
1606
1100

0330
1606
1100

0350
1606
1100

0500
1875
1100

0550
1875
1100

0600
1875
1100

0650
1875
1100

0700
1875
1100

0750
1975
1500

2950

2950

2950

2950

3260

3260

4010

4010

4010

4350

838

908

913

922

1079

1083

1386

1460

1540

1889

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

291

Code: SNRLFCUY.14 /1501

NRL
0800/1800
free-cooling

Air/Water chillers for outdoor installation with free cooling


Scroll compressors, plate exchangers and axial fans
Cooling capacity from 196452kW

R410A

HIGH EFFICIENCY VERSION


HIGH EFFICIENCY ALSO AT PARTIAL LOADS
SYSTEM SIDE INTEGRATED HYDRONIC KIT OPTION
Characteristics
The NRL free cooling are chillers, designed and
manufactured to meet air conditioning requirements in residential/commercial buildings or to
meet refrigeration requirements in industrial facilities.
They are outdoor units with scroll compressors,
axial fans, external copper coils with aluminium
fins and plate exchanger.
These chillers are also equipped with a Free cooling coil and are used when the refrigerant load
request persists even during the winter months, or
when the outdoor air temperature is below the
temperature of the return liquid from the system.
In Free cooling operation (mixed Free cooling and
compressors, or Free cooling only), the fluid is
cooled directly by the outdoor air, allowing even
the complete shutdown of compressors with a
significant energy saving. It is also possible to
have the Glycol free version for all those applications where the use of glycol is not allowed
Versions
NRL_FA High efficiency
NRL_FE Silenced

NRL_BA High efficiency without the use of glycol


NRL_BE Silenced without the use of glycol
Operating range: Work up to 44C of outdoor
air temperature at full load. For further details
refer to the selection software/technical documentation.
Unit with two refrigerant circuits designed to
provide maximum efficiency at full load,
ensuring high efficiency at partial loads also
and ensuring continuity in case one of the
two circuits stop.
Flow switch, water filter and standard high
and low pressure transducers
Possibility of integrated hydronic kit that
encloses the main hydraulic components; it is
available in different configurations with or
without storage, one or two high static pressure pumps
Three-way valve located on the water side for
water switching on the Free-Cooling coils
Device for electronically controlling the
series condensation, for operation even at
low temperatures or in free cooling, which

allows adjusting the air flow rate to actual


system demand with resulting advantages in
terms of consumption reduction.
Microprocessor adjustment, that allows isolating the condenser coils to maximise the free
cooling efficiency, even in mixed Free cooling and compressor operation
Complete, with keyboard and LCD display,
for easy consultation and intervention on the
unit via a menu available in several languages.
The presence of a programmable timer allows
setting time bands of operation and a possible
second set-point
The temperature control takes place with the
integral proportional logic, based on the
water output temperature.
Night Mode: it is possible to set a silenced
operation profile.
Perfect for night operation, since it guarantees
greater acoustic comfort in the evenings, and
a high efficiency in the time of greater load.

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol.
PGD1: Simplified remote panel. Allows performing
the basic controls of the unit with alarm signals.
MULTICHILLER_PCO: Control, switch-on and
switch-off system of the single chillers where multiple units are installed in parallel, always ensuring
constant ow rate to the exchangers.
AERWEB300: the AERWEB device allows the
remote control of a chiller by means of a common
PC through Ethernet connection, via a common
browser; 4 models available:

292

AERWEB300-6: Web server for monitoring and


Accessories mounted in the factory;
controlling maximum 6 RS485 network devices;
DRE: Peak current reduction electronic device.
AERWEB300-18: Web server for monitoring and
Only available with 400V power supply.
controlling maximum 18 RS485 network devices;
RIF: power factor correction, connected in parallel
AERWEB300-6G: Web server for monitoring and
to the motor, it allows a reduction of the input curcontrolling maximum 6 RS485 network devices
rent (approx. 10%).
with integrated GPRS modem;
PRM1: Manually-rearmed pressure switch, wired
AERWEB300-18G: Web server for monitoring and
in series to the high pressure switch on the ow
controlling maximum 18 RS485 network devices
pipe of the compressor.
with integrated GPRS modem;

GP: Protection grids for coils and cooling circuit.


VT: Group of anti-vibration mounts.

Mod. NRL
AER485P1
PGD1
AERWEB300
MULTICHILLER_PCO
GP
AVX

Vers.
Alls
Alls
Alls
Alls
Alls
00
P3/P4
03/04

0800

260
739
741
740

0900

260
739
744
743

1000

260
745
747
746

1250

350
748
750
749

1404

350
752
754
753

1504

350
757
758
753

1655

500
761
763
762

1800

500
766
763
762

Alls
Alls
Alls

801
88

901
90

1001
92

1251
92

1404
92

1504
92

1655
93

1801
94

Accessories mounted in the factory;


DRE
RIF
PRM1

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system
requirements.

Field
Description
1,2,3
NRL
4,5,6,7 Sizes
0800-0900-1000-1250-1404-1504-1655-1800
8
Scope of application
Standard (temperature of water produced up to +4 C)
Y Low temperature (temperature of water produced from +4C to -8C)
X Electronic thermostatic valve (temperature of water produced up to +4 C) for different temperatures, contact the supplier
9
Model
F Chiller with Free cooling
K Chiller with Free cooling and low pressure drops
B Chiller with Free cooling glycol free
10
Heat recovery
Without heat recovery
11
Version
A High efficiency
E Silenced high efficiency
12
Coils
Aluminium
R Copper
S Tinned copper
V Painted
13
Fans
Standard
J Inverter
14
Power supply
400V/3/50Hz with magnet circuit breakers
15-16 System side integrated hydronic kit (2)
00 Without hydronic kit
03 Storage tank with 1 high static pressure pump
04 Storage tank with 2 high static pressure pumps
P3 1 High static pressure pump
P4 2 High static pressure pumps

(2) In models glycol free "B" option kit hydronic system side is not available:
- In sizes 0800 to 1800 option 03/04

293

Technical Data
Freecooling Models
FA
FE
FA
FE
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA
FE
FA
FE
FA
FE

Cooling capacity
Input power
EER
Water flow rate
Total pressure drops
Cooling capacity
Input power
EER
Water flow rate
Total pressure drops

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

0800
210
196
75
80
2,81
2,46
36120
33730
77
68
182
178
7,5
24,30
23,76
36120
33730
105
93

0900
229
216
89
93
2,58
2,33
39390
37110
82
73
206
201
7,5
27,48
26,76
39390
37110
110
99

1000
247
228
103
109
2,41
2,09
42480
39210
81
69
229
223
7,5
30,53
29,76
42840
39210
110
94

1250
310
289
114
120
2,72
2,40
53320
49670
92
80
257
263
11,0
23,34
23,89
53320
49670
123
106

1404
337
310
136
145
2,48
2,14
57960
53260
98
84
291
288
11,0
26,47
26,19
57960
53260
131
110

1504
364
331
157
169
2,31
1,95
62610
56850
83
70
326
314
11,0
29,61
28,50
62610
56850
117
94

1655
430
400
159
169
2,70
2,37
73960
68770
104
90
399
396
14,5
27,48
27,33
73960
68770
140
117

1800
452
421
175
186
2,58
2,26
77740
72330
107
93
440
443
14,5
30,32
30,58
77740
72330
145
120

0800
153
147
11,1
7,50
13,78
19,60
36120
33730
77
68

0900
170
164
11,1
7,50
15,32
21,87
39390
37110
82
73

1000
186
181
11,1
7,50
16,76
24,13
42480
39210
81
69

1250
217
216
17,3
11,0
12,54
19,64
53320
49670
92
80

1404
242
241
17,3
11,0
13,99
21,91
57960
53260
98
84

1504
266
267
17,3
11,0
15,38
24,27
62610
56850
83
70

1655
328
327
23,2
14,50
14,14
22,55
73960
68770
104
90

1800
361
364
23,2
14,50
15,56
25,10
77740
72330
107
93

0800
214,2
199,9
75,0
80,0
2,86
2,50
36843
34387
64,8
56,5
174,6
7,5
23,3
35369
33011
88
77

0900
233,6
220,3
89,0
93,0
2,62
2,37
40176
37895
65,8
58,6
199,1
7,5
26,6
38569
36380
87
77

1000
251,9
232,6
103,0
109,0
2,45
2,13
43334
40001
70,2
59,8
223,7
7,5
29,8
41601
38401
91
78

1250
316,2
294,8
114,0
120,0
2,77
2,46
54387
50703
65,6
57,0
242,2
11
22,0
52212
48675
87
76

1404
343,7
316,2
136,0
145,0
2,53
2,18
59124
54387
69,1
58,5
275,0
11
25,0
56759
52212
90
77

1504
371,3
337,6
157,0
169,0
2,36
2,00
63861
58071
75,2
62,2
307,9
11
28,0
61306
55748
97
80

1655
438,6
408,0
159,0
169,0
2,76
2,41
75440
70177
95,5
82,6
378,5
14,5
26,1
72422
67370
126
109

1800
461,0
429,4
175,0
186,0
2,63
2,31
79300
73861
105,2
91,3
420,2
14,5
29,0
76128
70907
136
117

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Cooling in freecooling (100%)
Evaporator water temperature (in) 15 C; Outdoor air temperature 2C

Freecooling glycol free models


Cooling capacity

(1)
(1)

Input power
EER
Water flow rate
Total pressure drops

BA
BE
BA
BE
BA
BE
BA
BE
BA
BE

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C
(1) Performance in cooling, operation as chiller, are the same

Freecooling with low pressure loads models


Cooling capacity
Input power
EER
Water flow rate
Total pressure drops
Cooling capacity
Input power
EER
Water flow rate
Total pressure drops

KA
KE
KA
KE
KA
KE
KA
KE
KA
KE
KA/KE
KA/KE
KA/KE
KA
KE
KA
KE

kW
kW
kW
kW
W/W
W/W
l/h
l/h
kPa
kPa
kW
kW
W/W
l/h
l/h
kPa
kPa

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Cooling in freecooling (100%)
Evaporator water temperature (in) 15 C; Outdoor air temperature 2C

294

Technical data
GENERAL DATA
Electrical data
(2)
FA
(2)
FE
(2) FA/FE
(2) BA/BE
(2) KA/KE

Total input current (Chiller)


Total input current (freecooling)

A
A
A
A
A
A
A

Maximum current (FLA)


Peak current (LRA)
Compressors

type
n
n
type

Compressors
Circuits
Refrigerant gas
System side heat exchanger

1000

1250

1404

1504

1655

1800

144
149
15
21
15
177
352

169
174
15
21
15
199
408

195
203
15
21
15
221
430

208
217
22
33
22
274
542

252
265
22
34
22
290
624

296
312
22
34
22
320
654

298
310
30
45
30
357
691

317
332
30
45
30
406
674

1
4

1
4

1
4

1
4

6
112800
80700

8
155200
108600

8
153600
109800

scroll

R410A

(in/out)

1
3

1
3

1
3

A/E
A
E

type
n
m3/h
m3/h

4
79600
55700

4
78800
55200

4
78000
55800

Fans
Air flow rate
System side integrated hydronic kit
Storage tank
Useful static pressure
Sound data

0900

type
n

Heat exchanger
Hydraulic connections
Standard Fans

0800

(3)

plate

l
kPa

700

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Sound power
Sound Pressure
Electric power supply

88,5
82,5
56,5
50,5

1
4

axial
6
6
115200
114000
80600
79800

700
700
700
700
700
700
refer to the selection program or to the technical documentation
88,5
82,5
56,5
50,5

88,5
82,5
56,5
50,5

91,5
91
85,5
85
59,5
59,0
53,5
53,0
400V/3/50Hz

90,5
84,5
58,5
52,5

92
86
60,0
54,00

700

94
88
62,0
56,0

(2) The electric data is of the versions without integrated hydronic kit
(3) In models glycol free "B" option storage tank system side is not available
Sound power
Aermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested by Eurovent certification.
Sound Pressure
Sound pressure measured in free field, 10 m away from the unit external surface (in compliance with UNI EN ISO 3744).
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

Dimension and weight data

NRL_0800/0900/1000 A-E

NRL_1250/1404/1504 A-E

NRL_1655/1800 A-E

A
A

Mod. NRL
Height
Width

Length
Weight

(mm) A
(mm) B
(mm) C
(kg)

Vers.
All
All
All

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

0800
2450
2200
3400
2470

0900
2450
2200
3400
2650

1000
2450
2200
3400
2840

1250
2450
2200
4250
3120

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

1404
2450
2200
4250
3380

1504
2450
2200
4250
3660

1655
2450
2200
5750
4220

Code: SNRLFCUY.04 / 1502

1800
2450
2200
5750
4420

295

NRL

2000/3600
free-cooling

Air cooled chiller with axial fans


Cooling capacity from 446 kW to 904 kW

R410A

HIGH EFFICIENCY VERSION


LOW NOISE HIGH EFFICIENCY
VERSION
PUMP ASSEMBLY OPTION

4 REFRIGERANT CIRCUITS
PUMP ASSEMBLY AND BUFFER
TANK OPTION

Characteristics

Available in 7 sizes
external air temperature combined with
Refrigerant R410A
compressor operation at full or partial load
4 refrigerant circuits
- compressors only: the cooling capacity is
High efficiency even at part load
provided entirely by the compressors (standHeat exchangers optimised to benefit from the
ard operation of a chiller)
excellent heat transfer characteristics of R410A
Versions available:
High efficiency scroll compressors
- High efficiency
Axial fans with low sound level
- High efficiency low noise
Solid construction with polyester anti-corro- Glycol free
sion painted finish
- With pump assembly (high head, with/withOperation up to 44 C ambient in cooling
out standby pump)
mode
- With pump assembly and 700 litre buffer
Operation modes:
tanks complete with water filter, flow
- Free-Cooling only: is the most economical
switch, expansion tank, charging point and
way to use the unit. Only the fans operate
antifreeze electric heater
by speed control. Cooling is achieved com- Electronic expansion valve
pletely from the external air temperature
- Inverter fans
- combined Free-Cooling and compressors: Microprocessor control system of the comthe cooling capacity is achieved from the
pressors and fans for the control of the three

operating modes (Free-Cooling only, combined Free-Cooling and compressors, and


compressors only)
Display of all operating parameters in 4 languages.
Simplified remote control panel located up to
50 m distance away with shielded cable.
Permits basic control and alarm notifications
of the unit
High efficiency air-water coil (Free-Cooling)
with smooth tubes and wavy fins
Three-way valve installed on the hydraulic
circuit to modulate flow to the Free-Cooling
coils
High and low pressure transducers (standard
for all versions)
Fan speed controller for low ambient operation. In Free-Cooling mode controls capacity.

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
PGS: Daily/Weekly Programmer. Allows two
daily time-clock programmes (two switch on/
off cycles) and different programmes for each
day of the week.
GP: Protection grille protects the external coil

296

from accidental damage.


AVX: spring anti-vibration mounts.

time of order and is available factory fitted


only.
PRM1 and PRM2: FACTORY FITTED
ACCESSORY. A manual reset pressure switch
Factory fitted accessory
wired in series with the existing high pressure
RIF Power factor correction. Connected in parswitch installed on the compressor discharge
allel to the motor allowing about 10% reducline.
tion of input current. Must be requested at

Mod. NRL
AER485P1
PGS
GP

(1)

AVX

Vers.
All
All
All
00
P3/P4
03/04

2000
(x2)

260 (x2)

2250
(x2)

260 - 350

2500
(x2)

350 (x2)

2808
(x2)

350 (x2)

3008
(x2)

350 (x2)

3310
(x2)

500 (x2)

3600
(x2)

500 (x2)

770
772
771

776
778
777

782
784
783

788
790
789

794
796
795

801
803
802

801
803
802

All
All

2000

2250

2500

2808

3008

3310

3600

Factory fitted accessory


RIFNRL
PRM1/PRM2

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system
requirements.

Configuration fields:
123
|
Code

4567
8
9
10
11
|
|
|
|
|
|
|
Model
|
Version
|
|
|
Size Expansion valve
Heat recovery

Code:
NRL
Size:
2000, 2250, 2500, 2808, 3008, 3310, 3600
Expansion valve:
- Standard thermostatic expansion valve
Y - Thermostatic expansion valve with leaving liquid temperature
from +4C down to -6 C
X - Electronic thermostatic valve, max. temp. of water produced: +4C
(for lower temperatures please contact us)
Model:
F - Free-cooling
B - Free-cooling glycol free
Heat recovery
- Without heat recovery
D - With desuperheater (partial heat recovery)
Version:
A - High efficiency
E - High efficiency low noise version

12
|
|
|
Coil

13
|
Fan

14
|
|
|
Power supply

15-16
|
Integrated
hydronic
module

Coil:
- Aluminium
R - Copper
S - Tinned copper
V - Anti-corrosion coated aluminium (epoxy paint)
Fans:
- Standard
J - Inverter
Power supply:
- 400V 3~ 50Hz with circuit breakers
Integrated hydronic module:
00 - without pump or buffer tank
03 - single high head pump and buffer tank
04 - single and standby high head pump and buffer tank
P3 - single high head pump without buffer tank
P4 - single and standby high head pump without buffer tank

WARNING:
The model "B" (Free-cooling, Free-cooling glycol free)
glycol can not be provided with hydronic kit 03-04

Attention:
the standard options are shown by the symbol
Example of configuration code: NRL2000FA00
This is an NRL unit of size 2000, with standard thermostatic expansion valve, Free-cooling model, without heat recovery, high efficiency, with
aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, and without pump or buffer tank.

297

Technical Data
Mod. NRL

U.M.

Cooling capacity

kW

Total power input

kW

Water flow rate

l/h

Total pressure drop

kPa

EER
Input current

W/W
A

Cooling capacity

kW

Total power input

kW

Water flow rate

l/h

Total pressure drop

kPa

EER

W/W

Input current
Maximum current (FLA)
Starting current (LRA)
Compressors/circuits

A
A
A
n/n

Sound power

dB(A)

Sound pressure

dB(A)

Hydraulic connections
Air flow rate

m3/h

Vers.
A
E
A
E
A
E
A
E
A
E
A
E
A
E
All
A
E
A
E
A
E
A/E
A/E
A/E
A/E
A
E
A
E
All
A
E

2000
494
456
206
218
84970
78430
81
69
2,40
2,09
389
407
458
446
15
85115
78413
110
94
30,53
29,73
30
442
651
8/4
91,5
85,5
59,5
53,5
3"
156000
111600

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C
Cooling in freecooling (100%)
Evaporator water temperature (in) 15 C; Outdoor air temperature 2C

298

2250
557
517
217
229
95800
88920
92
80
2,57
2,26
403
421
486
486
19
95903
88871
123
107
25,58
25,58
37
495
763
8/4
93,3
87,3
61,5
55,3
3"/4
193200
136400

2500
620
578
228
240
106640
99420
92
80
2,72
2,41
417
435
514
526
22
106691
99330
123
107
23,36
23,91
44
548
816
8/4
94,5
88,5
62,5
56,5
4"
230400
161200

2808
674
620
272
290
115930
106640
98
84
2,48
2,14
504
529
582
576
22
115871
106518
131
111
26,45
26,18
44
606
815
8/4
94,0
88,0
62,0
56,0
4"
228000
159600

3008
728
662
314
338
125220
113860
83
70
2,32
1,96
592
624
652
627
22
125052
113706
117
97
29,64
28,50
44
664
873
8/4
93,5
87,5
61,5
55,5
4"
225600
161400

3310
860
800
318
338
147920
137600
104
90
2,70
2,37
597
621
798
792
29
147870
137540
140
122
27,52
27,31
59
747
1015
10/4
95,0
89,0
63,0
57,0
4"
310400
217200

3600
904
842
350
372
155490
144820
107
93
2,58
2,26
634
665
880
887
29
155459
144658
145
126
30,34
30,59
59
813
1081
12/4
97,0
91,0
65,0
59,0
4"
307200
219600

Dimensions (mm)

C
B

U.M.

Vers.

2000

2250

2500

2800

3000

3300

3600

Height

Mod. NRL-F / NRL-B


A

(mm)

A/E

2450

2450

2450

2450

2450

2450

2450

Width

(mm)

A/E

2200

2200

2200

2200

2200

2200

2200

Length

(mm)

A/E

6400

7250

8100

8100

8100

11100

11100

(Kg)

A/E

5670

6190

6700

7120

7580

9060

9330

Code: SNRLMSFCUY.03 / 1301

Weight empty

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

299

NEW

NSM

Air/Water chillers for outdoor installation with free cooling


Screw compressors, shell and tube heat exchangers and axial fans
Cooling capacity from 3062028kW

1402/9603
free cooling

R134a

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


ENERGY SAVING
MICRO-CHANNEL COIL
QUICK AND EASY INSTALLATION
NIGHT MODE

Features
The NSM free cooling are chillers,
designed and manufactured to meet air
conditioning requirements in residential/
commercial buildings or to meet refrigeration requirements in industrial facilities.
These are outdoor units with screw compressors, axial fans, micro-channel coils,
and shell and tube heat exchangers. The
base, the structure and the panels are
made of steel treated with rustproof polyester paint.
These chillers are also equipped with a
Free cooling coil and are used when the
refrigerant load request persists even during the winter months, or when the outdoor air temperature is below the temperature of the return liquid from the system. In
Free cooling operation (mixed Free cooling
and compressors, or Free cooling only),
the fluid is cooled directly by the outdoor
air, allowing even the complete shutdown
of compressors with a significant energy
saving.

at full load, ensuring high efficiency at


partial loads also and ensuring continuity in case one of the circuits stop.
The full range uses aluminium microchannel coils, ensuring very high levels
of efficiency. This allows using less
refrigerant compared to traditional copper/aluminium coils.
he possibility of using the electronic
thermostatic valve brings significant
benefits, in particular when the refrigerant is working at partial loads to the
benefit of energy efficiency of the unit.
IT is supplied as standard from size
52026402 e 84039603, optional for
all other sizes.
Standard differential pressure switch
Throttle valve in the hydraulic circuit for
water switching on the Free-Cooling
coils
DCPX series
Device for electronically controlling the
series condensation, for operation even
at low temperatures or in free cooling,
which allows adjusting the air flow rate
Versions
to actual system demand with resulting
NSM_F Free cooling
advantages in terms of consumption
NSM_P Free cooling plus
reduction.
Microprocessor adjustment, that allows
Operating range: Work up to 50C of outisolating the condenser coils to maximdoor air temperature at full load, dependise the free cooling efficiency, even in
ing on size and version. For further details
mixed Free cooling and compressor
refer to the selection software/technical
operation
documentation.
- Complete, with keyboard and LCD dis Unit with 2/3 refrigerant circuits
play, for easy consultation and intervendesigned to provide maximum efficiency
tion on the unit via a menu available in

300

several languages.
- The presence of a programmable timer
allows setting time bands of operation
and a possible second set-point
- The temperature control takes place with
the integral proportional logic, based on
the water output temperature.
- Night Mode: it is possible to set a
silenced operation profile.
Perfect for night operation, since it guarantees greater acoustic comfort in the
evenings, and a high efficiency in the
time of greater load.

Accessories
AER485P1: RS-485 interface for supervising
and controlling maximum 18 RS485 network
systems with MODBUS protocol.
devices with integrated GPRS modem;
AERWEB300: the AERWEB device allows the PRV3: Allows you to control the chiller at a
remote control of a chiller by means of a
distance.
common PC through Ethernet connection, via MULTICHILLER_PCO: Control, switch-on
a common browser; 4 models available:
and switch-off system of the single chillers
AERWEB300-6: Web server for monitoring and
where multiple units are installed in parallel,
controlling maximum 6 RS485 network devices;
always ensuring constant flow rate to the
AERWEB300-18: Web server for monitoring and
evaporators.
controlling maximum 18 RS485 network devices; AVX: Spring anti-vibration mounts.
AERWEB300-6G: Web server for monitoring
and controlling maximum 6 RS485 network
devices with integrated GPRS modem;
AERWEB300-18G: Web server for monitoring

Accessories mounted in the factory;


KRS: Exchangers electric resistance
KRSDES: Electrical resistor for desuperheater
RIFNSM: Current power factor correction.
Connected in parallel to the motor, it allows a
reduction of the input current (approx. 10%).
GP: Anti-intrusion grids.
AK: ACOUSTIC KIT.
This accessory further reduce the noise.

Accessories compatibility
Mod.
vers.
AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
AVX
(1)

1402
(x2)

1602
(x2)

1802
(x2)

2002
(x2)

2202
(x2)

2352
(x2)

2502
(x2)

2652
(x2)

2802
(x2)

3002
(x2)

3202
(x2)

3402
(x2)

3602
(x2)

3902
(x2)

4202
(x2)

4502
(x2)

22
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

24
24
24
24

24
24
24
24

24
24
24
24

24
24
24
24

24
24
24
23+23

Accessories mounted in the factory;


KRS
A
22
E
23
U
23
N
23

KRS_DES
RIFNSM
1402
GP
A
4V
es. (GP4V)
E
4V
U
4V
N
5V

AK
(2)

AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
AVX
(1)

1602
4V
4V
4V
5V

1802
4V
5V
5V
6V

2002
4V
5V
5V
6V

2202
5V
5V
5V
6V

2352
5V
6V
6V
7V

2502
5V
6V
6V
7V

2652
6V
7V
7V
8V

2802
6V
7V
7V
8V

3002
6V
7V
7V
8V

3202
6V
7V
7V
8V

3402
7V
8V
8V
9V

3602
7V
8V
8V
10V

3902
8V
9V
9V
11V

4202
8V
10V
10V
11V

4502
9V
10V
10V
6V+7V

4802
(x2)

5202
(x2)

5602
(x2)

6002
(x2)

6402
(x2)

6503
(x3)

6703
(x3)

6903
(x3)

7203
(x3)

8403
(x3)

9603
(x3)

24
24
24
23+23

24
23+23
23+23
23+23

24
23+23
23+23
23+23

24
23+23
23+23
23+23

24+23
24+23
24+23
24+23

24+23
24+23
24+23

24+23
24+23
24+23

24+23
24+23
24+23

24+23

24+23

Accessories mounted in the factory;


KRS
A
24
E
24
U
24
N
23+23

KRS_DES
(1)
RIFNSM
4802
GP
A
9V
es. (GP9V)
E
11V
U
11V
N
7V+7V

AK
(2)

5202
9V
11V
11V
7V+8V

5602
10V
6V+6V
6V+6V
8V+8V

6002
11V
6V+7V
6V+7V
8V+8V

6402
11V
7V+7V
7V+7V
8V+8V

6503
6703
6903
7203
8403
9603
8V+4V 8V+4V 9V+5V 9V+5V 10V+5V 11V+6V
9V+5V 10V+5V 10V+5V 11V+6V
9V+5V 10V+5V 10V+5V 11V+6V
11V+6V

(1) Accessories to be defined for compatibility


(2) The accessory is only available for the "E/N" silenced versions
(x2) Indicates the amount to order

301

Choosing the unit


By appropriately combining the variety of options available, every model can be configured in order to meet all specific system requirements.
Field
1,2,3
4,5,6,7

Y
X
Z
9
F
P
10

D
11
A
E
U
N
12

O
R
S
V
13

J
14

8
2
4
5
9
15-16
00
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
FROM
DB
DC
DD
DE
DF
DG
DH
DI
DJ

Description
NSM
Sizes
1402-1602-1802-2002-2202-2352-2502-2652-2802-3002-3202 (dual circuit)
3402-3602-3902-4202-4502-4802-5202-5602-6002-6402 (dual circuit)
6503-6703-6903-7203-8403-9603 (triple circuit)
Scope of application
Standard (temperature of water produced up to +4 C) (3)
Low temperature (temperature of water produced from +4C to -6C) (4)
Electronic thermostatic valve (temperature of water produced up to +4 C)
Low temperature electronic thermostatic valve (temperature of water produced from +4C to -6C) (4)
Model
Free cooling
Free cooling Plus (5)
Heat recovery
Without heat recovery
With desuperheater
Version
High efficiency
Silenced high efficiency
Very high efficiency
Silenced very high efficiency
Free cooling water coils
Condensing coils
Aluminium microchannel
Copper Aluminium
Painted aluminium microchannel
Painted Aluminium Copper
Copper - Copper
Copper Copper
Copper - Thinned
Copper - Thinned
Epoxy paint (only free cooling coil)
Epoxy paint (only free cooling coil)
Fans
Standard
Inverter
Power supply
400V/3/50Hz with fuses
400V/3/50Hz with magnet circuit breakers
230V/3/50Hz with fuses (6)
230V/3/50Hz with magnet circuit breakers (6)
500V/3/50Hz with fuses (7)
500V/3/50Hz with magnet circuit breakers (7)
Integrated hydronic kit
Without hydronic kit
Pumping unit (pump A)
Pumping unit (pump B)
Pumping unit (pump C)
Pumping unit (pump D)
Pumping unit (pump E)
Pumping unit (pump F)
Pumping unit (pump G)
Pumping unit (pump H)
Pumping unit (pump I)
Pumping unit (pump J)
Pumping unit (pump A and reserve pump)
Pumping unit (pump B and reserve pump)
Pumping unit (pump C and reserve pump)
Pumping unit (pump D and reserve pump)
Operation of pumps in parallel
Pumping unit (pump E and reserve pump)
TF Double static, pressure pump (pump F)
Pumping unit (pump F and reserve pump)
TG Double static, pressure pump (pump G)
Pumping unit (pump G and reserve pump)
TH Double static, pressure pump (pump H)
Pumping unit (pump H and reserve pump)
TI Double static, pressure pump (pump I)
Pumping unit (pump I and reserve pump)
TJ Double static, pressure pump (pump J)
Pumping unit (pump J and reserve pump)

(3)sizes from 52026402 and 84039603 come standard with the electronic thermostatic valve
(4) The Y/Z option is not compatible with the D option
(5) The free cooling plus models can have coils only in options "" and "O"
(6) 230V/3/50Hz available only for sizes from 14022202
(7) 500V/3/50Hz available only for sizes from 14023202

302

Technical data
NSM Free cooling mod.
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Cooling capacity

Input power

EER

Water flow rate

Total pressure drops

Cooling capacity

Input power

EER

Total pressure drops

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

1402
306
320
328
326
103
106
105
104
2.98
3.03
3.12
3.15
52710
55010
56430
56080
45
33
35
35
348
309
356
365
15
11
15
14
23.18
28.07
23.76
26.56
66
57
60
52

1602
350
366
378
377
118
123
121
119
2.98
2.97
3.12
3.16
60230
62920
65100
64760
59
37
40
39
362
317
370
381
15
11
15
14
24.14
28.87
24.67
27.71
86
67
72
62

2602
397
418
429
424
137
138
136
134
2.90
3.04
3.15
3.16
68250
71840
73840
73010
54
32
34
33
373
390
451
449
15
14
19
16
24.88
28.36
24.07
27.24
86
57
60
52

2002
451
473
492
486
158
159
156
154
2.85
2.97
3.16
3.16
77490
81350
84600
83650
36
37
40
39
382
399
466
466
15
14
19
16
25.47
29.03
24.88
28.22
76
68
74
64

2202
505
509
531
525
169
178
173
171
2.99
2.85
3.07
3.07
86910
87560
91390
90360
45
43
47
46
468
403
473
473
19
14
19
16
24.97
29.33
25.26
28.69
79
78
85
74

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

2352
522
550
569
560
180
183
180
178
2.90
3.00
3.16
3.14
89860
94560
97800
96260
48
50
54
52
471
476
555
541
19
16
22
19
25.14
28.88
24.68
28.13
84
80
86
77

2502
557
569
589
580
194
195
191
189
2.86
2.91
3.08
3.06
95730
97840
101320
99710
54
54
58
56
476
479
559
546
19
16
22
19
25.42
29.04
24.87
28.36
95
86
92
82

2652
601
619
638
626
203
205
202
201
2.96
3.01
3.15
3.12
103340
106400
109730
107690
63
54
57
55
561
552
642
616
22
19
26
22
24.93
28.69
24.45
27.99
98
83
88
80

2802
650
646
668
655
220
220
216
215
2.95
2.93
3.09
3.05
111770
111160
114860
112670
67
59
63
61
569
557
649
622
22
19
26
22
25.30
28.91
24.71
28.29
107
90
96
87

3002
678
675
695
683
235
236
228
228
2.89
2.86
3.04
3.00
116690
116120
119550
117420
73
64
68
66
573
560
654
628
22
19
26
22
25.48
29.11
24.93
28.54
117
98
104
94

3202
726
716
736
723
253
254
242
243
2.87
2.82
3.04
2.98
124920
123070
126550
124420
65
65
69
67
579
565
662
635
22
19
26
22
25.73
29.34
25.21
28.86
114
103
109
99

3402
813
797
825
812
270
271
263
264
3.02
2.94
3.14
3.08
139890
137040
141870
139610
43
43
46
45
671
643
753
714
26
22
30
25
25.59
29.25
25.12
28.84
87
77
83
75

3602
873
852
891
889
296
297
288
283
2.95
2.87
3.09
3.14
150120
146490
153260
152870
50
49
54
54
678
648
764
791
26
22
30
27
25.83
29.47
25.46
28.77
100
88
96
83

3902
954
930
968
961
318
320
311
307
3.00
2.90
3.11
3.13
164110
159900
166490
165230
61
60
65
64
770
727
854
867
30
25
34
30
25.68
29.38
25.31
28.67
108
98
106
94

Cooling in freecooling (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C

Electrical data
Total input current
(Chiller)

Total input current


(Free cooling)

Maximum current FLA

Peak current LRA

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
Quantity

(1)
(1)
(1)
(1)

FA
FE
FU
FN

Standard Fans
Quantity

Air flow rate

FA
FE
FU
FN
FA
FE
FU
FN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
no.
no.
no.
no.
m3/h
m3/h
m3/h
m3/h

182
177
186
175
30
16
30
20
244
244
244
252
265
265
265
274

206
206
212
200
30
16
30
20
272
272
272
280
307
307
307
316

231
223
232
218
30
20
38
24
299
308
308
316
350
359
359
367

268
261
266
253
30
20
38
24
332
341
341
349
388
397
397
405

291
294
297
283
38
20
38
24
374
374
374
383
420
420
420
428

311
305
313
297
38
24
46
28
396
404
404
413
467
475
475
484

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

8
8
8
8
10
8
8
10
10
10
8
8
10
10
10
10
10
12
12
12
116000 116000 116000 116000 145000
89600 89600 112000 112000 112000
116000 116000 145000 145000 145000
112000 112000 134400 134400 134400

10
12
12
14
145000
134400
174000
156800

335
351
326
342
332
353
317
335
38
46
24
28
46
53
28
32
417
450
425
459
425
459
434
467
484
519
492
528
492
528
501
536
twin-screw
2
2
2
2
R134a
shell and tube
1
1
1
1
1
1
1
1
axial
10
12
12
14
12
14
14
16
145000 174000
134400 156800
174000 203000
156800 179200

378
365
374
357
46
28
53
32
475
483
483
492
529
538
538
546

400
389
392
376
46
28
53
32
475
483
483
492
529
538
538
546

427
415
413
399
46
28
53
32
475
483
483
492
529
538
538
546

451
437
443
427
53
32
61
36
531
540
540
548
662
670
670
679

487
474
477
452
53
32
61
40
579
588
588
605
702
710
710
727

530
517
523
497
61
36
68
44
636
644
644
667
831
840
840
863

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

12
14
14
16
174000
156800
203000
179200

12
14
14
16
174000
156800
203000
179200

12
14
14
16
174000
156800
203000
179200

14
16
16
18
203000
179200
232000
201600

14
16
16
20
203000
179200
232000
224000

16
18
18
22
232000
201600
261000
246400

100
93
100
93

100
93
100
93

100
93
100
93

100
94
101
94

100
94
101
95

101
95
102
95

Sound data
Sound power
Electric power supply

FA
FE
FU
FN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

98
91
98
92

98
91
98
92

98
92
99
92

98
92
99
92

99
92
99
93

99
93
100
93

99
100
93
93
100
100
93
93
400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

303

Technical data
NSM Free cooling mod.
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Cooling capacity

Input power

EER

Water flow rate

Total pressure drops

Cooling capacity

Input power

EER

Total pressure drops

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

4202
997
995
1031
1005
346
340
332
333
2.88
2.93
3.11
3.02
171460
171170
177350
172840
66
69
74
70
775
804
942
874
30
27
37
30
25.83
29.24
25.12
28.91
117
105
113
102

4502
1082
1052
1095
1099
366
370
358
350
2.96
2.84
3.06
3.14
186150
180890
188350
188960
81
80
86
71
867
809
952
1018
34
27
37
36
25.71
29.44
25.39
28.48
130
119
129
101

4802
1128
1137
1181
1162
392
389
379
369
2.88
2.92
3.12
3.15
194070
195570
203160
199810
88
74
79
85
872
889
1043
1092
34
30
41
38
25.85
29.38
25.30
28.37
141
113
122
114

5202
1167
1159
1209
1218
422
418
405
393
2.76
2.77
2.98
3.10
200780
199390
207920
209510
75
76
83
89
876
891
1048
1165
34
30
41
41
25.96
29.44
25.40
28.24
131
117
128
118

5602
1223
1217
1266
1274
439
437
426
416
2.79
2.79
2.97
3.06
210330
209370
217720
219210
82
68
73
75
966
967
1135
1237
37
33
45
44
25.77
29.31
25.22
28.11
134
107
116
104

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

6002
1305
1279
1326
1318
453
449
440
434
2.88
2.85
3.01
3.04
224450
220070
228110
226710
96
72
78
78
1058
1044
1222
1246
41
36
49
44
25.66
29.20
25.07
28.33
146
111
119
109

6402
1347
1342
1387
1362
472
461
454
451
2.85
2.91
3.06
3.02
231640
230760
238500
234210
102
82
88
85
1063
1120
1308
1255
41
38
52
44
25.77
29.09
24.92
28.52
155
120
128
118

6503
6703
6903
7203
8403
9603
2028
1459
1502
1659
1705
1838
1434
1500
1599
1684
1491
1554
1667
1753
1478
492
520
557
583
659
704
491
511
569
588
478
499
550
570
472
2.97
2.89
2.98
2.92
2.79
2.88
2.92
2.93
2.81
2.86
3.12
3.12
3.03
3.07
3.13
250990 258340 285350 293260 316150 348840
246660 257930 274970 289650
256480 267340 286650 301470
254300
61
66
81
88
82
102
60
69
80
74
65
74
86
80
64
1637
1158
1163
1347
1352
1449
1130
1207
1216
1295
1326
1414
1431
1523
1339
64
45
45
52
52
56
38
41
41
44
52
56
56
60
47
25.68
25.75 25.85 25.66 25.75 25.78
29.35 29.26 29.48
29.44
25.27 25.14 25.45
25.39
28.65
155
108
117
130
141
134
98
105
119
113
106
113
130
123
94

Cooling in freecooling (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C

Electrical data
Total input current

(1)
(1)
(1)
(1)
(1)

Total input current


(Free cooling)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
Quantity

(1)
(1)
(1)
(1)

FA
FE
FU
FN

Standard Fans
Quantity

Air flow rate

FA
FE
FU
FN
FA
FE
FU
FN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
no.
no.
no.
no.
m3/h
m3/h
m3/h
m3/h

581
555
564
544
61
40
76
44
684
701
701
715
858
875
875
890

614
601
605
570
68
40
76
52
731
740
740
771
931
939
939
971

655
632
639
600
68
44
84
56
770
793
793
819
953
976
976
1002

704
678
682
639
68
44
84
60
813
836
836
870
1108
1131
1131
1165

733
708
718
677
76
48
91
64
865
888
888
922
1164
1187
1187
1221

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
2

1
1
1
2

1
1
1
2

1
2
2
2

16
20
20
22
232000
224000
290000
246400

18
20
20
26
261000
224000
290000
291200

18
22
22
28
261000
246400
319000
313600

18
22
22
30
261000
246400
319000
336000

20
24
24
32
290000
268800
348000
358400

101
95
102
95

102
95
102
96

102
95
102
96

761
796
732
755
746
774
708
740
84
84
52
56
99
106
64
64
913
947
930
973
930
973
956
990
1290
1287
1307
1313
1307
1313
1333
1330
twin-screw
2
3
2
3
R134a
shell and tube
1
1
2
2
2
2
2
2
axial
22
22
26
28
26
28
32
32
319000 319000
291200 313600
377000 406000
358400 358400

821
804
812
771
91
56
106
68
981
998
998
1023
1069
1086
1086
1112

872
832
846

945
924
926

986
945
954

1100

1198

91
60
114

106
60
114

106
64
122

114

129

1029
1054
1054

1124
1132
1132

1163
1180
1180

1300

1419

1096
1122
1122

1200
1209
1209

1223
1240
1240

1480

1603

3
3

3
3

3
3

3
3

3
3

3
3

2
2
2
2

2
2
2

2
2
2

2
2
2

24
24
28
28
30
34
28
30
30
32
28
30
30
32
34
348000 348000 406000 406000 435000 493000
313600 336000 336000 358400
406000 435000 435000 464000
380800

Sound data
Sound power
Electric power supply

FA
FE
FU
FN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

102
102
96
96
102
103
97
97
400V/3/50Hz

102
96
103
97

102
96
103
97

103
96
103
97

103
96
104

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

304

103
96
104

103
97
104

104

104

Technical data
NSM Free cooling PLUS mod.
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN

Cooling capacity

Input power

EER

Water flow rate

Total pressure drops

Cooling capacity

Input power

EER

Total pressure drops

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

1402
306
317
327
325
104
107
106
104
2.95
2.97
3.08
3.11
52600
54470
56230
55920
45
33
35
35
372
329
381
388
15
11
15
14
24.41
29.48
25.04
27.79
66
56
59
52

1602
349
363
377
375
119
125
123
120
2.94
2.91
3.07
3.12
60090
62460
64790
64530
59
37
39
39
388
339
397
406
15
11
15
14
25.48
30.36
26.04
29.12
86
66
71
61

2602
395
414
428
423
138
139
138
136
2.86
2.99
3.11
3.12
67940
71290
73540
72740
53
32
34
33
400
416
483
478
15
14
19
17
26.27
29.81
25.39
28.57
85
56
60
52

2002
447
470
489
484
160
161
157
155
2.79
2.91
3.10
3.11
76940
80760
84070
83170
35
37
40
39
409
426
500
497
15
14
19
17
26.86
30.53
26.26
29.68
75
67
73
63

2202
502
504
528
522
171
181
175
173
2.94
2.79
3.02
3.02
86360
86710
90740
89790
44
42
46
45
502
430
507
505
19
14
19
17
26.36
30.82
26.65
30.18
78
77
84
73

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

2352
519
545
565
557
183
185
182
180
2.84
2.94
3.11
3.09
89280
93810
97250
95770
47
50
53
52
505
508
595
578
19
17
23
20
26.53
30.37
26.05
29.58
83
79
85
76

2502
553
564
586
577
197
198
193
192
2.81
2.85
3.03
3.01
95050
97020
100720
99190
54
53
57
55
511
511
600
582
19
17
23
20
26.81
30.54
26.25
29.83
94
84
91
81

2652
597
614
635
623
205
208
204
203
2.91
2.96
3.10
3.07
102710
105580
109150
107170
63
53
57
55
601
589
688
656
23
20
27
22
26.31
30.17
25.80
29.42
97
82
87
79

2802
645
641
664
652
223
223
218
217
2.89
2.87
3.04
3.00
111010
110230
114220
112100
66
58
62
60
610
594
695
664
23
20
27
22
26.69
30.41
26.09
29.75
106
89
95
86

3002
674
670
692
680
238
239
231
231
2.83
2.80
2.99
2.94
115990
115210
118970
116890
73
63
67
65
614
598
702
670
23
20
27
22
26.88
30.62
26.32
30.03
115
97
103
94

3202
722
711
732
720
257
258
246
246
2.81
2.76
2.98
2.92
124160
122270
125990
123890
64
64
68
66
620
602
709
678
23
20
27
22
27.12
30.84
26.61
30.37
112
102
108
98

3402
808
791
820
807
273
275
266
267
2.96
2.88
3.08
3.02
138940
135990
141090
138810
43
42
46
44
719
686
808
762
27
22
30
25
26.98
30.75
26.51
30.35
86
76
82
74

3602
865
843
885
883
299
301
291
286
2.89
2.80
3.04
3.09
148770
145080
152170
151850
49
48
53
53
725
691
818
844
27
22
30
28
27.20
30.95
26.85
30.26
98
86
95
82

3902
947
921
962
955
322
324
315
310
2.94
2.84
3.06
3.08
162860
158470
165430
164280
60
59
64
64
825
775
915
925
30
25
34
31
27.07
30.87
26.71
30.16
106
96
104
93

Cooling in freecooling (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C

Electrical data
Total input current
(Chiller)

(1)
(1)
(1)
(1)
(1)

Total input current


(Free cooling)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN
PA
PE
PU
PN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
Quantity

(1)
(1)
(1)
(1)

PA
PE
PU
PN

Standard Fans
Quantity

Air flow rate

PA
PE
PU
PN
PA
PE
PU
PN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
no.
no.
no.
no.
m3/h
m3/h
m3/h
m3/h

184
179
187
176
31
16
31
20
244
244
244
252
265
265
265
274

208
208
213
201
31
16
31
20
272
272
272
280
307
307
307
316

233
225
234
220
31
20
38
24
299
308
308
316
350
359
359
367

271
263
269
255
31
20
38
24
332
341
341
349
388
397
397
405

294
298
300
286
38
20
38
24
374
374
374
383
420
420
420
428

315
308
316
300
38
24
46
28
396
404
404
413
467
475
475
484

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

8
8
8
8
10
8
8
10
10
10
8
8
10
10
10
10
10
12
12
12
109600 109600 109600 109600 137000
85600 85600 107000 107000 107000
109600 109600 137000 137000 137000
107000 107000 128400 128400 128400

10
12
12
14
137000
128400
164400
149800

339
355
329
345
335
356
320
338
38
46
24
28
46
54
28
32
417
450
425
459
425
459
434
467
484
519
492
528
492
528
501
536
twin-screw
2
2
2
2
R134a
shell and tube
1
1
1
1
1
1
1
1
axial
10
12
12
14
12
14
14
16
137000 164400
128400 149800
164400 191800
149800 171200

382
369
377
360
46
28
54
32
475
483
483
492
529
538
538
546

405
393
396
381
46
28
54
32
475
483
483
492
529
538
538
546

433
421
418
404
46
28
54
32
475
483
483
492
529
538
538
546

456
443
447
431
54
32
61
36
531
540
540
548
662
670
670
679

492
480
482
457
54
32
61
40
579
588
588
605
702
710
710
727

536
523
528
501
61
36
69
44
636
644
644
667
831
840
840
863

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

12
14
14
16
164400
149800
191800
171200

12
14
14
16
164400
149800
191800
171200

12
14
14
16
164400
149800
191800
171200

14
16
16
18
191800
171200
219200
192600

14
16
16
20
191800
171200
219200
214000

16
18
18
22
219200
192600
246600
235400

100
93
100
93

100
93
100
93

100
93
100
93

100
94
101
94

100
94
101
95

101
95
102
95

Sound data
Sound power
Electric power supply

PA
PE
PU
PN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

98
91
98
92

98
91
98
92

98
92
99
92

98
92
99
92

99
92
99
93

99
93
100
93

99
100
93
93
100
100
93
93
400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

305

Technical data
NSM Free cooling PLUS mod.
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Cooling capacity

Input power

EER

Water flow rate

Total pressure drops

Cooling capacity

Input power

EER

Total pressure drops

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

4202
989
988
1025
999
351
344
335
337
2.82
2.87
3.06
2.97
170060
169860
176350
171790
65
68
73
70
829
857
1010
933
30
28
38
31
27.21
30.74
26.51
30.41
116
103
111
101

4502
1074
1042
1088
1093
370
375
362
353
2.90
2.78
3.00
3.09
184760
179210
187150
187940
80
78
85
71
929
862
1020
1086
34
28
38
36
27.09
30.92
26.78
29.96
128
117
128
100

4802
1119
1127
1174
1156
397
395
383
373
2.82
2.86
3.06
3.10
192490
193870
201920
198770
87
72
78
84
933
947
1119
1165
34
31
42
39
27.22
30.87
26.70
29.84
139
111
121
113

5202
1156
1148
1201
1212
428
424
410
396
2.70
2.71
2.93
3.06
198900
197450
206550
208410
74
75
82
88
936
949
1123
1242
34
31
42
42
27.32
30.92
26.80
29.69
129
115
126
117

5602
1213
1207
1258
1268
444
442
431
420
2.73
2.73
2.92
3.02
208590
207550
216360
218050
81
67
72
74
1034
1031
1216
1319
38
33
46
45
27.15
30.81
26.62
29.55
132
105
114
103

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

6002
1295
1269
1319
1311
458
454
444
438
2.83
2.79
2.97
3.00
222770
218320
226790
225490
94
71
77
77
1133
1113
1310
1330
42
36
50
45
27.05
30.70
26.46
29.79
144
109
118
108

6402
1336
1332
1379
1354
478
467
458
455
2.79
2.85
3.01
2.97
229830
229100
237230
232920
100
81
87
85
1137
1194
1402
1339
42
39
53
45
27.15
30.59
26.30
30.01
153
118
127
117

6503
6703
6903
7203
8403
9603
2013
1448
1490
1647
1692
1823
1422
1488
1583
1668
1482
1545
1656
1742
1470
498
527
564
591
667
712
498
517
577
597
483
504
556
577
477
2.83
2.91
2.83
2.92
2.86
2.73
2.86
2.88
2.74
2.80
3.07
3.07
2.98
3.02
3.08
249020 256220 283280 291010 313530 346260
244540 255930 272310 286960
254900 265810 284790 299560
252840
60
65
80
87
81
100
59
68
78
72
64
73
85
79
64
1752
1240
1244
1442
1447
1551
1204
1287
1295
1380
1422
1516
1533
1632
1429
46
46
53
53
57
65
39
42
42
45
53
57
57
61
47
27.13 27.22 27.04 27.13 27.15
27.07
30.84 30.76 30.95
30.92
26.66 26.54 26.84
26.78
30.14
153
106
116
128
139
132
96
103
117
111
104
111
128
121
93

Cooling in freecooling (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C

Electrical data
(1)

Total input current

(1)
(1)
(1)
(1)

Total input current


(Free cooling)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN
FA
FE
FU
FN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
(1)

Quantity

(1)
(1)
(1)

FA
FE
FU
FN

Standard Fans
Quantity

Air flow rate

FA
FE
FU
FN
FA
FE
FU
FN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
no.
no.
no.
no.
m3/h
m3/h
m3/h
m3/h

588
561
569
550
61
40
77
44
684
701
701
715
858
875
875
890

621
609
611
575
69
40
77
52
731
740
740
771
931
939
939
971

662
640
645
606
69
44
84
56
770
793
793
819
953
976
976
1002

713
687
688
644
69
44
84
60
813
836
836
870
1108
1131
1131
1165

741
717
725
682
77
48
92
64
865
888
888
922
1164
1187
1187
1221

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
2

1
1
1
2

1
1
1
2

1
2
2
2

16
20
20
22
219200
214000
274000
235400

18
20
20
26
246600
214000
274000
278200

18
22
22
28
246600
235400
301400
299600

18
22
22
30
246600
235400
301400
321000

20
24
24
32
274000
256800
328800
342400

101
95
102
95

102
95
102
96

102
95
102
96

769
805
740
763
752
780
714
746
84
84
52
56
100
107
64
64
913
947
930
973
930
973
956
990
1290
1287
1307
1313
1307
1313
1333
1330
twin-screw
2
2
2
2
R134a
shell and tube
1
1
2
2
2
2
2
2
axial
22
22
26
28
26
28
32
32
301400 301400
278200 299600
356200 383600
342400 342400

830
814
819
778
92
56
107
68
981
998
998
1023
1069
1086
1086
1112

882
842
854

956
937
936

998
957
963

1112

1211

92
60
115

107
60
115

107
64
123

115

131

1029
1054
1054

1124
1132
1132

1163
1180
1180

1300

1419

1096
1122
1122

1200
1209
1209

1223
1240
1240

1480

1603

3
3

3
3

3
3

3
3

3
3

3
3

2
2
2
2

2
2
2

2
2
2

2
2
2

24
24
28
28
30
34
28
30
30
32
28
30
30
32
34
328800 328800 383600 383600 411000 465800
299600 321000 321000 342400
383600 411000 411000 438400
363800

Sound data
Sound power
Electric power supply

FA
FE
FU
FN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

102
102
96
96
102
103
97
97
400V/3/50Hz

102
96
103
97

102
96
103
97

103
96
103
97

103
96
104

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

306

103
96
104

103
97
104

104

104

Dimensions and Weights

Mod. NSM Free cooling and Free cooling plus


Vers
Height
(mm)
A
All
Width
(mm)
B
All
A
E
Length
(mm)
C
U
N

Height
Width

(mm)
(mm)

A
B

Length

(mm)

Height
Width

(mm)
(mm)

A
B

Length

(mm)

Height
Width

(mm)
(mm)

A
B

Length

(mm)

1402
2450
2200
5160
5160
5160
6350

1602
2450
2200
5160
5160
5160
6350

1802
2450
2200
5160
6350
6350
7140

2002
2450
2200
5160
6350
6350
7140

2202
2450
2200
6350
6350
6350
7140

2352
2450
2200
6350
7140
7140
8330

2502
2450
2200
6350
7140
7140
8330

2652
2450
2200
7140
8330
8330
9520

Vers
All
All
A
E
U
N

2802
2450
2200
7140
8330
8330
9520

3002
2450
2200
7140
8330
8330
9520

3202
2450
2200
7140
8330
8330
9520

3402
2450
2200
8330
9520
9520
10710

3602
2450
2200
8330
9520
9520
11900

3902
2450
2200
9520
10710
10710
13090

4202
2450
2200
9520
11900
11900
13090

4502
2450
2200
10710
11900
11900
15470

Vers
All
All
A
E
U
N

4802
2450
2200
10710
13090
13090
16660

5202
2450
2200
10710
13090
13090
17850

5602
2450
2200
11900
14280
14280
19040

6002
2450
2200
13090
15470
15470
19040

6402
2450
2200
13090
16660
16660
19040

6503
2450
2200
14280
16660
16660
20230

6703
2450
2200
14280
17850
17850

6903
2450
2200
16660
17850
17850

Vers
All
All
A
E
U
N

7203
2450
2200
16660
19040
19040

8403
2450
2200
17850

9603
2450
2200
20230

For transport reasons, units with depth greater than 13090 mm are shipped separately. For further information, refer to the technical and/or
installation manual.
Aermec reserves the right to make all the modifications deemed
necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

307

Code: SNSMFCUY.00 / 1501

NS
1251/7203

Chillers with freecooling HWT


Air/Water outdoor installation
Axial fans and twin-rotor screw compressor
Cooling capacity 2511542kW

free-cooling
HWT

R134a
Designed for

DATA CENTERS &


PROCESS COOLING
Applications

HIGH EFFICIENCY VERSION


HIGH EFFICIENCY EVEN AT PART LOAD
OPERATES TO 46 C AMBIENT
WATER PRODUCTION UP TO 30 C
OPTION VERSION WITH BUILT-IN HYDRONIC KIT

Characteristics
Chillers with freecooling
Version
NS_WFA High efficiency version
NS_WFE High efficiency low noise version
Operational limits (1)
- max. external air temperature 46C

Shell and tube evaporator optimised for


refrigerant R134a
Pressure switch as standard supply
Three-way valve installed on the hydraulic circuit to modulate flow to the Free-cooling coil
Partial heat recovery (option) desuperheater)
Option integrated hydronic mudule, it consist of 1
or 2 pumps and 2 exspansion tanks (25l.)
1/3 circuiti frigoriferi
Axial fans for extremely quiet operation
1/3 refrigerant circuits
High efficiency, low noise screw compressors Modulating capacity control microprocessor
system
with modulating capacity control from 40 to
100%. (25 to 100% with electronic expan- Multilingual display panel
Metal control panel with anti-corrosion polysion valve option)

ester paint
Fan speed control standard (DCPX)
The low nois version "E" is equipped:
- Compressor acoustical enclosure
- Hot gas discharge muffler.

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervision
remote control max. 6 units in RS485 netsystems with MODBUS protocol.
work with integrated GPRS modem;
AERWEB300: Accessory AERWEB allows
AERWEB300-18G: Web server to monitor and
remote control of a chiller through a comremote control max. 18 units in RS485 netmon PC and an ethernet connection over a
work with integrated GPRS modem;
common browser; 4 versions available:
PRV3: Remote control of the chiller operating
AERWEB300-6: Web server to monitor and
functions.
remote control max. 6 units in RS485 net MULTICHILLER: Control system for multiple
work;
parallel installed constant flow chillers proAERWEB300-18: Web server to monitor and
viding individual chiller on/off and control
remote control max. 18 units in RS485 netcapability.
work;
AVX: Spring anti-vibration mounts.
AERWEB300-6G: Web server to monitor and

308

Accessories factory fitted only


KRSDES: Evaporator and heat recovery
exchangers trace heating.
RIFNS: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
AK: ACUSTIC KIT
(only for Versions E)
This accessory allows further sound reduction. Must be requested at time of order and
is available factory fitted only.

Compatibility of accessories
Mod. NS
AER485P1
AERWEB300
PRV3
MULTICHILLER
Accessories factory fitted only
KRS_DES
(1)
RIFNS
GP300M
GP400M
GP500M
GP300B
GP400B
GP500B
GP300M+300M
AK
(2)

vers.
Alls
Alls
Alls
Alls

AER485P1
AERWEB300
PRV3
MULTICHILLER
Accessories factory fitted only
KRS_DES
(1)
RIFNS
GP300M+300M
GP300M+400M
GP400M+400M
GP400M+500M
GP500M+500M
GP400M+400M+500M
GP400M+500M+500M
GP500M+500M+400M
AK
(2)

Alls
Alls
Alls
Alls

spring antivibration
esempio:
RIFNS1251F
AVX

(3)

Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls
FE

Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls
Alls
FE

1251
(x1)

1401
(x1)

1601
(x1)

1801
(x1)

2101
(x1)

2401
(x1)

1402
(x2)

1602
(x2)

1802
(x2)

2002
(x2)

2202
(x2)

2352
(x2)

2502
(x2)

2652
(x2)

2802
(x2)

3002
(x2)

KRS10DES KRS10DES KRS11DES KRS11DES KRS11DES KRS11DES KRS19DES KRS19DES KRS18DES KRS18DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS13DES

1251F 1401F 1601F 1801

2101

2401

1402

1602

1802

2002

2202

2352

2502

2652

2802 3002F

3202
(x2)

3402
(x2)

3602
(x2)

3902
(x2)

4202
(x2)

4502
(x2)

4802
(x2)

5002
(x2)

5202
(x2)

5402
(x2)

5702
(x2)

6003
(x3)

6303
(x3)

6603
(x3)

6903
(x3)

7203
(x3)

KRS14DES KRS13DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES

3202F 3402F 3602

3902

4202

4502

4802

5002

5202

5402

5702

6003

6303

6603

6903

7203

1251

1401

1601

1801

2101

2401

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

3202

3402

3602

3902

4202

4502

4802

5002

5202

5402

5702

6003

6303

6603

6903

7203

(1) The accessory comes standard with the electrical heater


(2) The accessory is only available for the low noise version "FE"
(3) Development order
(x2) the number in brackets indicates the quantity to order

309

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2
3,4,5,6

7
W
8
F
9

10
A
E
11

R
S
V
12

M
J
13

8
14-15
00
PA
PB
PC
PD
PE
PF
PG
PH
PJ
PK
PN
PO
PP
PQ

Code
NS
Size
1251-1401-1601-1801-2101-2401 (single module 1 circuits)
1402-1602-1802-2002-2202-2352-2502-2652-2802 (single module 2 circuits)
3002-3202-3402-3602-3902-4202-4502-4802-5002-5202-5402-5702 (double module 2 circuits)
6003-6303-6603-6903-7203 (three module 3 circuits)
Expansion valve:
Electronic expansion valve, leaving water temperature from +5C up to +30C
Model
Frecooling
Heat ecovery
Without recovery
Version
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans
Standard
High static pressure
Inverter
Power supply
400V/3/50Hz with fuses
400V/3/50Hz with circuit breakers
Hydronic kit
Without hydronic kit
Hydronic pump (Pump A)
Hydronic pump (A Pump and reserve pump)
Hydronic pump (C Pump)
Hydronic pump (C Pump and reserve pump)
Hydronic pump (E Pump)
Hydronic pump (E Pump and reserve pump)
Hydronic pump (G Pump)
Hydronic pump (G Pump and reserve pump)
Hydronic pump (J Pump)
Hydronic pump (J Pump and reserve pump)
Hydronic pump (N Pump) (3)
Hydronic pump (N Pump and reserve pump) (3)
Hydronic pump (P Pump) (3)
Hydronic pump (P Pump and reserve pump) (3)

(3) not available for size 12511801/14022002/30024202/60036603

310

Technical Data
Mod NS freecooling HWT
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA
FE
BA
BE
FA
FE
FA
FE
FA
FE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop (Chiller)
Total pressure drop (Freecooing)

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa
kPa
kPa

1251
265
251
71
73
3,73
3,44
265
251
12
22,1
20,9
12,7
12,8
45580
43172
55
49
84
75

1401
306
286
83
86
3,69
3,33
306
286
12
25,5
23,8
11,3
11,9
52632
49192
56
49
95
83

1601
331
307
88
94
3,76
3,27
331
307
12
27,6
25,6
10,7
11,6
56932
52804
45
39
92
80

1801
398
367
101
106
3,94
3,46
398
367
16
24,9
22,9
12,2
12,8
68456
63124
71
61
147
125

2101
459
424
113
117
4,06
3,62
459
424
20
23,0
21,2
12,7
13,2
78948
72928
76
65
142
121

2401
514
472
129
135
3,98
3,50
514
472
20
25,7
23,6
11,7
12,5
88408
81184
96
81
183
154

1402
304
285
80
85
3,80
3,35
304
285
12
25,3
23,8
11,1
10,2
52288
49020
50
44
91
80

1602
340
314
98
103
3,47
3,05
340
314
12
28,3
26,2
10,1
10,9
58480
54008
62
53
114
97

1251

1401

1601

1801

2101

2401

1402

1602

123
125
24
159
281

142
147
24
182
322

157
163
24
197
376

179
185
32
228
438

196
201
40
259
446

234
241
40
292
492

148
152
24
188
288

174
181
24
210
304

Cooling
Evaporator water temperature (in/out) 25C/20C; external air temperature 35C
Freecooling (100%)
Evaporator water temperature (in) 25C

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Freecooling)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1)
FA
(1)
FE
(1) FA/FE
FA/FE
FA/FE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

FA
FE

Air flow rate (Freecooling)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Freecooling)


Power supply

two screw two screw two screw two screw two screw two screw two screw two screw
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
6
102000
70000
102000

axial
6
102000
78000
102000

62
54
62
94
86
94
400V/3

63
55
63
95
87
95
400V/3

kPa
FA
FE

Sound pressure (Freecooling)


Sound power (Chiller)

A
A
A
A
A

FA
FE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


1
1
1
refer to the technical manual

axial
axial
axial
axial
6
8
10
10
102000
136000
170000
170000
87000
100000
112000
127000
102000
136000
170000
170000
refer to the technical manual
refer to the technical manual

axial
6
102000
74000
102000

axial
6
102000
80000
102000

65
57
65
97
89
97
400V/3

64
56
64
96
88
96
400V/3

65
57
65
97
89
97
400V/3

65
57
65
97
89
97
400V/3

66
57
66
98
90
98
400V/3

66
58
66
98
90
98
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

311

Technical Data
Mod NS freecooling HWT
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA
FE
BA
BE
FA
FE
FA
FE
FA
FE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop (chiller)
Total pressure drop (Freecooling)

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa
kPa
kPa

1802
411
382
110
114
3,74
3,35
411
382
16
25,7
23,9
11,4
11,9
70692
65704
72
62
155
134

2002
445
419
118
122
3,77
3,43
445
419
20
22,3
21,0
12,2
12,0
76540
72068
82
73
147
131

2202
472
436
122
126
3,87
3,46
472
436
20
23,6
21,8
12,5
13,1
81184
74992
79
68
153
130

2352
493
461
133
139
3,71
3,32
493
461
20
24,7
23,1
12,2
12,6
84796
79292
87
76
168
147

2502
520
483
143
150
3,64
3,22
520
483
20
26,0
24,2
11,6
12,2
89440
83076
97
84
188
162

2652
550
509
155
164
3,55
3,10
550
509
20
27,5
25,5
11,1
11,8
94600
87548
107
92
212
182

2802
574
543
167
177
3,44
3,07
574
543
20
28,7
27,2
10,7
11,3
98728
93396
119
107
237
212

3002
637
593
171
180
3,73
3,29
637
593
24
26,5
24,7
11,0
11,7
109564
101996
50
43
94
81

1802

2002

2202

2352

2502

2652

2802

3002

196
201
32
244
332

208
212
40
264
377

212
217
40
276
389

229
236
40
293
415

245
254
40
310
432

265
277
40
333
473

284
298
40
356
496

299
310
48
379
558

Cooling
Evaporator water temperature (in/out) 25C/20C; external air temperature 35C
Freecooling (100%)
Evaporator water temperature (in) 25C

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Freecooling)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1)
FA
(1)
FE
(1) FA/FE
FA/FE
FA/FE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

FA
FE

Air flow rate (Freecooling)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Freecooling)


Power supply

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
8
136000
96000
136000

axial

axial

170000
124500
170000

65
57
65
97
89
97
400V/3

66
57
66
98
90
98
400V/3

kPa
FA
FE

Sound pressure (Freecooling)


Sound power (Chiller)

A
A
A
A
A

FA
FE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


1
1
1
refer to the technical manual

axial

axial

170000
170000
170000
170000
120000
123000
130000
130000
170000
170000
170000
170000
refer to the technical manual
refer to the technical manual

170000
140000
170000

204000
165000
204000

66
58
66
98
90
98
400V/3

67
59
67
99
91
99
400V/3

66
58
66
99
91
99
400V/3

axial

66
58
66
98
90
98
400V/3

axial

66
58
66
98
90
98
400V/3

axial

67
59
67
99
91
99
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

312

Technical Data
Mod NS freecooling HWT
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA
FE
BA
BE
FA
FE
FA
FE
FA
FE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop (chiller)
Total pressure drop (Freecooling)

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa
kPa
kPa

3202
662
614
176
188
3,76
3,27
662
614
24
27,6
25,6
10,7
11,6
113864
105608
45
39
93
80

3402
729
674
189
200
3,86
3,37
729
674
28
26,0
24,1
11,5
12,2
125388
115928
57
49
117
100

3602
796
734
202
212
3,94
3,46
796
734
32
24,9
22,9
12,2
12,8
136912
126248
71
60
147
125

3902
857
791
214
223
4,00
3,55
857
791
36
23,8
22,0
12,5
13,0
147404
136052
74
63
144
123

4202
912
839
230
241
3,97
3,48
912
839
36
25,3
23,3
12,0
12,6
156864
144308
84
71
166
140

4502
973
896
242
252
4,02
3,56
973
896
40
24,3
22,4
12,2
12,8
167356
154112
86
73
162
137

4802
1028
944
258
270
3,98
3,50
1028
944
40
25,7
23,6
11,7
12,5
176816
162368
96
81
183
154

5002
1087
1003
281
296
3,87
3,39
1087
1003
40
27,2
25,1
10,8
11,7
186964
172516
102
87
179
153

3202

3402

3602

3902

4202

4502

4802

5002

314
326
48
394
573

336
348
56
425
635

358
370
64
456
666

375
386
72
487
674

413
426
72
520
720

430
442
80
551
751

468
482
80
584
784

496
514
80
601
920

Cooling
Evaporator water temperature (in/out) 25C/20C; external air temperature 35C
Freecooling (100%)
Evaporator water temperature (in) 25C

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Freecooling)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1)
FA
(1)
FE
(1) FA/FE
FA/FE
FA/FE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

FA
FE

Air flow rate (Freecooling)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Freecooling)


Power supply

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
12
204000
174000
204000

axial
14
238000
187000
238000

67
59
67
100
92
100
400V/3

67
59
67
100
92
100
400V/3

kPa
FA
FE

Sound pressure (Freecooling)


Sound power (Chiller)

A
A
A
A
A

FA
FE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


2
2
2
refer to the technical manual

axial
axial
axial
axial
16
18
18
20
272000
306000
306000
340000
200000
212000
227000
239000
272000
306000
306000
340000
refer to the technical manual
refer to the technical manual

axial
20
340000
254000
340000

axial
20
340000
254000
340000

67
59
67
100
92
100
400V/3

68
60
68
101
93
101
400V/3

69
61
69
102
94
102
400V/3

68
60
68
101
93
101
400V/3

68
60
68
101
93
101
400V/3

68
60
68
101
93
101
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

313

Technical Data
Mod NS freecooling
FA
FE
FA
FE
FA
FE
FA
FE
FA/FE
FA
FE
BA
BE
FA
FE
FA
FE
FA
FE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop (chiller)
Total pressure drop (Freecooling)

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa
kPa
kPa

5202
1146
1062
304
322
3,77
3,30
1146
1062
40
28,7
26,6
10,2
11,0
197112
182664
103
88
170
146

5402
1205
1113
332
354
3,63
3,14
1205
1113
40
30,1
27,8
9,7
10,5
207260
191436
108
92
177
151

5702
1264
1164
360
386
3,51
3,02
1264
1164
40
31,6
29,1
9,1
10,0
217408
200208
116
99
189
160

600
1310
1206
331
347
3,96
3,48
1310
1206
52
25,2
23,2
12,0
12,7
225320
207432
79
67
159
135

6303
1371
1263
343
358
4,00
3,53
1371
1263
56
24,5
22,6
12,2
12,8
235812
217236
81
69
157
134

6603
1426
1311
359
376
3,97
3,49
1426
1311
56
25,5
23,4
11,9
12,6
245272
225492
89
75
168
142

6903
1487
1368
371
387
4,01
3,53
1487
1368
60
24,8
22,8
12,0
12,7
255764
235296
96
81
182
154

7203
1542
1416
387
405
3,98
3,50
1542
1416
60
25,7
23,6
11,7
12,5
265224
243552
100
85
179
151

5202

5402

5702

6003

6303

6603

6903

7203

524
546
80
618
937

568
596
80
657
1001

612
646
80
696
1040

592
611
104
748
948

609
627
112
779
979

647
667
112
812
1012

664
683
120
843
1043

702
723
120
876
1076

Cooling
Evaporator water temperature (in/out) 12C/7C; external air temperature 35C
Freecooling (100%)
Evaporator water temperature (in) 15 C; external air temperature 2C

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Freecooling)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1)
FA
(1)
FE
(1) FA/FE
FA/FE
FA/FE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

FA
FE

Air flow rate (Freecooling)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Freecooling)


Power supply

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
3
3
3
3
3
2
2
2
3
3
3
3
3
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
20
340000
254000
340000

axial
20
340000
254000
340000

69
63
69
102
94
102
400V/3

69
63
69
102
94
102
400V/3

kPa
FA
FE

Sound pressure (Freecooling)


Sound power (Chiller)

A
A
A
A
A

FA
FE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


3
3
3
refer to the technical manual

axial
axial
axial
axial
20
26
28
28
340000
442000
476000
476000
254000
327000
339000
354000
340000
442000
476000
476000
refer to the technical manual
refer to the technical manual

axial
30
510000
366000
510000

axial
30
510000
381000
510000

69
63
69
102
94
102
400V/3

69
63
69
103
95
103
400V/3

69
63
69
103
95
103
400V/3

69
62
69
102
94
102
400V/3

69
62
69
102
94
102
400V/3

70
63
70
103
95
103
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

314

Dimensions (mm)

NS12512401
(single module 1 circuits)

NS14022802
(single module 2 circuits)

NS30025702
(double module 2 circuits)

NS60037203
(three module 3 circuits)

A
A

C
B

B
C

C
B
B

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
Alls
Alls
Alls
Alls

1251
2450
2200
3780
3468

1401
2450
2200
3780
3482

1601
2450
2200
3780
3840

1801
2450
2200
4770
4622

2101
2450
2200
5750
5509

2401
2450
2200
5750
5530

1402
2450
2200
3780
3668

1602
2450
2200
3780
4030

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
Alls
Alls
Alls
Alls

1802
2450
2200
4770
4730

2002
2450
2200
5750
5182

2202
2450
2200
5750
5232

2352
2450
2200
5750
5769

2502
2450
2200
5750
5745

2652
2450
2200
5750
5760

2802
2450
2200
5750
5774

3002
2450
2200
7160
6913

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
Alls
Alls
Alls
Alls

3202
2450
2200
7160
7310

3402
2450
2200
8150
8023

3602
2450
2200
9140
8424

3902
2450
2200
10120
9761

4202
2450
2200
10120
10032

4502
2450
2200
11100
10213

4802
2450
2200
11100
10420

5002
2450
2200
11100
11706

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
Alls
Alls
Alls
Alls

5202
2450
2200
11100
12312

5402
2450
2200
11100
12385

5702
2450
2200
11100
12458

6003
2450
2200
14490
13954

6303
2450
2200
15470
15291

6603
2450
2200
15470
15562

6903
2450
2200
16450
15743

7203
2450
2200
16450
15950

Cod.: SNSFCHWTUY.02 / 1411

For transport reasons Versions FA and FE, sizes 6003 to 7203, are shipped separated; one module consisting of two compressors and standard
electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the compressor side beneath
the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or
installation manual.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

315

NEW

NSM

Air/Water chillers for outdoor installation with free cooling glycol free
Screw compressors, shell and tube heat exchangers and axial fans
Cooling capacity from 3062028kW

1402/9603
glycol free

R134a

HIGH EFFICIENCY ALSO AT PARTIAL LOADS


ENERGY SAVING
MICRO-CHANNEL COIL
QUICK AND EASY INSTALLATION
NIGHT MODE

Features
- The temperature control takes place with the
circuits stop.
integral proportional logic, based on the
The full range uses aluminium micro-channel
water output temperature.
coils, ensuring very high levels of efficiency.
This allows using less refrigerant compared to - Night Mode: it is possible to set a silenced
operation profile.
traditional copper/aluminium coils.
Perfect for night operation, since it guarantees
he possibility of using the electronic thermogreater acoustic comfort in the evenings, and
static valve brings significant benefits, in para high efficiency in the time of greater load.
ticular when the refrigerant is working at partial loads to the benefit of energy efficiency of
the unit. IT is supplied as standard from size
52026402 e 84039603, optional for all
other sizes.
Intermediate plate heat exchanger, it permits
to obtain a double circuit set:
Coil circuit with glycol, in order to protect
the component from freezing.
Primary plant circuit, without glycol.
Standard differential pressure switch
DCPX series
Device for electronically controlling the
series condensation, for operation even at
low temperatures or in free cooling, which
allows adjusting the air flow rate to actual
system demand with resulting advantages in
terms of consumption reduction.
Versions
Microprocessor adjustment, that allows isolatNSM_B Free cooling glycol free
ing the condenser coils to maximise the free
NSM_G Free cooling plus glycol free
cooling efficiency, even in mixed Free cooling and compressor operation
Operating range: Work up to 50C of outdoor
- Complete, with keyboard and LCD display,
air temperature at full load, depending on size
for easy consultation and intervention on the
and version. For further details refer to the selecunit via a menu available in several languagtion software/technical documentation.
es.
Unit with 2/3 refrigerant circuits designed to
- The presence of a programmable timer allows
provide maximum efficiency at full load,
setting time bands of operation and a possible
ensuring high efficiency at partial loads also
second set-point
and ensuring continuity in case one of the
The NSM free cooling glycol free designed and
manufactured to meet air conditioning requirements in residential/commercial buildings or to
meet refrigeration requirements in industrial
facilities.
These are outdoor units with screw compressors, axial fans, micro-channel coils, and shell
and tube heat exchangers. The base, the structure and the panels are made of steel treated
with rustproof polyester paint.
These chillers are provided with a "free cooling" coil
and a intermediate plate heat exchanger, in order to
accomplish a double set of independent, a coil circuit / a plant circuit.
These chillers are used when the refrigerant load
request persists even during the winter months,
or when the outdoor air temperature is below
the temperature of the return liquid from the
system. In Free cooling operation (mixed Free
cooling and compressors, or Free cooling only),
the fluid is cooled directly by the outdoor air,
allowing even the complete shutdown of compressors with a significant energy saving.

316

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: the AERWEB device allows the
remote control of a chiller by means of a
common PC through Ethernet connection, via
a common browser; 4 models available:
AERWEB300-6: Web server for monitoring and
controlling maximum 6 RS485 network devices;
AERWEB300-18: Web server for monitoring and
controlling maximum 18 RS485 network devices;
AERWEB300-6G: Web server for monitoring
and controlling maximum 6 RS485 network
devices with integrated GPRS modem;
AERWEB300-18G: Web server for monitoring
and controlling maximum 18 RS485 network

devices with integrated GPRS modem;


Provides stand-still protection down to -20C.
PRV3: Allows you to control the chiller at a
Must be ordered in conjunction with
distance.
options KRS
MULTICHILLER_PCO: Control, switch-on RIFNSM: Current power factor correction.
and switch-off system of the single chillers
Connected in parallel to the motor, it allows a
where multiple units are installed in parallel,
reduction of the input current (approx. 10%).
always ensuring constant flow rate to the GP: Anti-intrusion grids.
evaporators.
AK: ACOUSTIC KIT.
AVX: Spring anti-vibration mounts.
This accessory further reduce the noise.
Accessories mounted in the factory;
KRS: (compulsory accessory) Exchangers
electric resistance
KDI: double thickness evaporator insulation.

Accessories compatibility
Mod.
vers.
AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
AVX
(1)

1402
(x2)

1602
(x2)

1802
(x2)

2002
(x2)

2202
(x2)

2352
(x2)

2502
(x2)

2652
(x2)

2802
(x2)

3002
(x2)

3202
(x2)

3402
(x2)

3602
(x2)

3902
(x2)

4202
(x2)

4502
(x2)

22
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

23
23
23
23

24
24
24
24

24
24
24
24

24
24
24
24

24
24
24
24

24
24
24
23+23

Accessories mounted in the factory;


KRS
(2)
A
22
E
23
U
23
N
23

KDI
(1)
RIFNSM
1402
GP
A
4V
es. (GP4V)
E
4V
U
4V
N
5V

AK
(3)

AER485P1
AERWEB300
PRV3
MULTICHILLER_PCO
AVX
(1)

1602
4V
4V
4V
5V

1802
4V
5V
5V
6V

2002
4V
5V
5V
6V

2202
5V
5V
5V
6V

2352
5V
6V
6V
7V

2502
5V
6V
6V
7V

2652
6V
7V
7V
8V

2802
6V
7V
7V
8V

3002
6V
7V
7V
8V

3202
6V
7V
7V
8V

3402
7V
8V
8V
9V

3602
7V
8V
8V
10V

3902
8V
9V
9V
11V

4202
8V
10V
10V
11V

4502
9V
10V
10V
6V+7V

4802
(x2)

5202
(x2)

5602
(x2)

6002
(x2)

6402
(x2)

6503
(x3)

6703
(x3)

6903
(x3)

7203
(x3)

8403
(x3)

9603
(x3)

24
24
24
23+23

24
23+23
23+23
23+23

24
23+23
23+23
23+23

24
23+23
23+23
23+23

24+23
24+23
24+23
24+23

24+23
24+23
24+23

24+23
24+23
24+23

24+23
24+23
24+23

24+23

24+23

Accessories mounted in the factory;


KRS
(2)
A
24
E
24
U
24
N
23+23

KDI
(1)
RIFNSM
4802
GP
A
9V
es. (GP9V)
E
11V
U
11V
N
7V+7V

AK
(3)

5202
9V
11V
11V
7V+8V

5602
10V
6V+6V
6V+6V
8V+8V

6002
11V
6V+7V
6V+7V
8V+8V

6402
11V
7V+7V
7V+7V
8V+8V

6503
6703
6903
7203
8403
9603
8V+4V 8V+4V 9V+5V 9V+5V 10V+5V 11V+6V
9V+5V 10V+5V 10V+5V 11V+6V
9V+5V 10V+5V 10V+5V 11V+6V
11V+6V

(1) Accessories to be defined for compatibility


(2) Compulsory accessory
(3) The accessory is only available for the "E/N" silenced versions
(x2) Indicates the amount to order

317

Choosing the unit


By appropriately combining the variety of options available, every model can be configured in order to meet all specific system requirements.
Field
1,2,3
4,5,6,7

Y
X
Z
9
B
G
10

11
A
E
U
N
12

O
R
S
V
13

M
J
14

8
2
4
5
9
15-16
00

Description
NSM
Sizes
1402-1602-1802-2002-2202-2352-2502-2652-2802-3002-3202 (dual circuit)
3402-3602-3902-4202-4502-4802-5202-5602-6002-6402 (dual circuit)
6503-6703-6903-7203-8403-9603 (triple circuit)
Scope of application
Standard (temperature of water produced up to +4 C) (3)
Low temperature (temperature of water produced from +4C to -6C) (4)
Electronic thermostatic valve (temperature of water produced up to +4 C)
Low temperature electronic thermostatic valve (temperature of water produced from +4C to -6C) (4)
Model
Free cooling glycol free
Free cooling Plus glycol free (5)
Heat recovery
Without heat recovery
Version
High efficiency
Silenced high efficiency
Very high efficiency
Silenced very high efficiency
Free cooling water coils
Condensing coils
Copper Aluminium
Aluminium microchannel
Painted Aluminium Copper
Painted aluminium microchannel
Copper Copper
Copper - Copper
Copper - Thinned
Copper - Thinned
Epoxy paint (only free cooling coil)
Epoxy paint (only free cooling coil)
Fans
Standard
Increased
Inverter
Power supply
400V/3/50Hz with fuses
400V/3/50Hz with magnet circuit breakers
230V/3/50Hz with fuses (6)
230V/3/50Hz with magnet circuit breakers (6)
500V/3/50Hz with fuses (7)
500V/3/50Hz with magnet circuit breakers (7)
Integrated hydronic kit
Without hydronic kit

(3)sizes from 52026402 and 84039603 come standard with the electronic thermostatic valve
(4) The Y/Z option is not compatible with the D option
(5) The free cooling plus models can have coils only in options "" and "O"
(6) 230V/3/50Hz available only for sizes from 14022202
(7) 500V/3/50Hz available only for sizes from 14023202

318

Technical data
Mod NSM Free cooling glycol free
BA
BE
Cooling capacity
BU
BN
BA
BE
Input power
BU
BN
BA
BE
EER
BU
BN
BA
BE
Water flow rate
BU
BN
BA
BE
Total pressure drops
BU
BN
BA
BE
Cooling capacity
BU
BN
BA
BE
Input power
BU
BN
BA
BE
EER
BU
BN
BA
BE
Total pressure drops
BU
BN

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

1402
306
320
328
326
103
106
105
104
2,98
3,03
3,12
3,15
52710
55010
56430
56080
73
64
67
54
263
244
271
288
18
15
19
18
14,37
16,02
14,11
15,97
73
64
67
54

1602
350
366
378
377
118
123
121
119
2,98
2,97
3,12
3,16
60230
62920
65100
64760
94
76
81
65
271
251
279
304
18
15
19
20
14,80
16,49
14,53
15,45
94
76
81
65

2602
397
418
429
424
137
138
136
134
2,90
3,04
3,15
3,16
68250
71840
73840
73010
100
84
88
67
278
302
332
358
18
20
25
26
15,18
15,46
13,53
13,81
100
84
88
67

2002
451
473
492
486
158
159
156
154
2,85
2,97
3,16
3,16
77490
81350
84600
83650
72
78
83
83
289
316
360
368
18
20
27
26
15,73
16,06
13,39
14,22
72
78
83
83

2202
505
509
531
525
169
178
173
171
2,99
2,85
3,07
3,07
86910
87560
91390
90360
90
90
96
96
355
321
363
374
25
20
27
27
14,40
16,35
13,52
14,07
90
90
96
96

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

2352
522
550
569
560
180
183
180
178
2,90
3,00
3,16
3,14
89860
94560
97800
96260
96
88
93
92
358
385
432
428
25
26
32
30
14,50
14,74
13,46
14,42
96
88
93
92

2502
557
569
589
580
194
195
191
189
2,86
2,91
3,08
3,06
95730
97840
101320
99710
108
94
99
98
362
388
435
432
25
26
32
30
14,69
14,88
13,55
14,56
108
94
99
98

2652
601
619
638
626
203
205
202
201
2,96
3,01
3,15
3,12
103340
106400
109730
107690
107
100
106
79
436
436
488
494
32
30
37
33
13,59
14,70
13,31
15,05
107
100
106
79

2802
650
646
668
655
220
220
216
215
2,95
2,93
3,09
3,05
111770
111160
114860
112670
117
109
88
86
440
440
511
499
32
30
37
33
13,72
14,85
13,83
15,20
117
109
88
86

3002
678
675
695
683
235
236
228
228
2,89
2,86
3,04
3,00
116690
116120
119550
117420
100
91
95
93
461
459
516
503
32
30
37
33
14,26
15,31
13,96
15,34
100
91
95
93

3202
726
716
736
723
253
254
242
243
2,87
2,82
3,04
2,98
124920
123070
126550
124420
94
94
87
86
465
463
531
518
32
30
37
33
14,39
15,46
14,32
15,73
94
94
87
86

3402
813
797
825
812
270
271
263
264
3,02
2,94
3,14
3,08
139890
137040
141870
139610
81
80
85
84
541
527
591
578
37
33
41
39
14,58
16,02
14,46
14,70
81
80
85
84

3602
873
852
891
889
296
297
288
283
2,95
2,87
3,09
3,14
150120
146490
153260
152870
93
92
99
100
546
532
597
630
37
33
41
42
14,71
16,16
14,58
14,95
93
92
99
100

3902
954
930
968
961
318
320
311
307
3,00
2,90
3,11
3,13
164110
159900
166490
165230
112
110
117
106
602
585
652
690
41
36
45
45
14,70
16,39
14,59
15,34
112
110
117
106

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C;
Coil circuit glycol 30%; Plant circuit glycol 0%

Electrical data
Total input current
(Chiller)

Total input current


(Free cooling glycol free)

Maximum current FLA

Peak current LRA

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

BA
BE
BU
BN
BA
BE
BU
BN
BA
BE
BU
BN
BA
BE
BU
BN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
Quantity

(1)
(1)
(1)
(1)

BA
BE
BU
BN

Standard Fans
Quantity

Air flow rate

BA
BE
BU
BN
BA
BE
BU
BN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

182
177
186
175
36
23
38
27
250
251
251
260
271
273
273
281

206
206
212
200
36
23
38
30
278
279
279
290
313
314
314
326

231
223
232
218
36
30
48
40
305
317
317
332
356
369
369
383

268
261
266
253
37
30
52
40
339
351
355
365
394
407
410
421

291
294
297
283
48
30
52
41
384
384
388
400
430
430
434
445

311
305
313
297
48
40
62
45
406
420
420
430
477
492
492
501

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

8
8
8
8
10
8
8
10
10
10
8
8
10
10
10
10
10
12
12
12
116000 116000 116000 116000 145000
89600 89600 112000 112000 112000
116000 116000 145000 145000 145000
112000 112000 134400 134400 134400

10
12
12
14
145000
134400
174000
156800

335
351
326
342
332
353
317
335
48
62
40
45
62
71
45
50
427
466
442
476
442
476
451
485
494
536
509
545
509
545
518
555
twin-screw
2
2
2
2
R134a
shell and tube
1
1
1
1
1
1
1
1
axial
10
12
12
14
12
14
14
16
145000 174000
134400 156800
174000 203000
156800 179200

378
365
374
357
62
45
71
50
491
501
501
510
546
555
556
565

400
389
392
376
62
46
71
50
492
501
501
510
546
556
556
565

427
415
413
399
62
46
71
50
492
501
502
510
546
556
556
565

451
437
443
427
71
50
79
60
550
558
558
572
680
689
689
703

487
474
477
452
71
50
79
64
598
606
606
629
720
729
729
751

530
517
523
497
79
54
87
68
654
663
663
691
850
858
858
887

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

12
14
14
16
174000
156800
203000
179200

12
14
14
16
174000
156800
203000
179200

12
14
14
16
174000
156800
203000
179200

14
16
16
18
203000
179200
232000
201600

14
16
16
20
203000
179200
232000
224000

16
18
18
22
232000
201600
261000
246400

100
93
100
93

100
93
100
93

100
93
100
93

100
94
101
94

100
94
101
95

101
95
102
95

Sound data
Sound power
Electric power supply

BA
BE
BU
BN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

98
91
98
92

98
91
98
92

98
92
99
92

98
92
99
92

99
92
99
93

99
93
100
93

99
100
93
93
100
100
93
93
400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

319

Technical data
Mod NSM Free cooling glycol free
BA
BE
Cooling capacity
BU
BN
BA
BE
Input power
BU
BN
BA
BE
EER
BU
BN
BA
BE
Water flow rate
BU
BN
BA
BE
Total pressure drops
BU
BN
BA
BE
Cooling capacity
BU
BN
BA
BE
Input power
BU
BN
BA
BE
EER
BU
BN
BA
BE
Total pressure drops
BU
BN

kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
l/h
l/h
l/h
l/h
kPa
kPa
kPa
kPa
kW
kW
kW
kW
kW
kW
kW
kW
W/W
W/W
W/W
W/W
kPa
kPa
kPa
kPa

4202
997
995
1031
1005
346
340
332
333
2,88
2,93
3,11
3,02
171460
171170
177350
172840
122
125
119
116
606
647
739
697
41
42
52
45
14,82
15,27
14,09
15,49
122
125
119
116

4502
1082
1052
1095
1099
366
370
358
350
2,96
2,84
3,06
3,14
186150
180890
188350
188960
132
128
137
103
682
665
746
817
45
42
52
56
15,19
15,66
14,22
14,64
132
128
137
103

4802
1128
1137
1181
1162
392
389
379
369
2,88
2,92
3,12
3,15
194070
195570
203160
199810
143
130
138
104
684
718
804
864
45
45
56
59
15,23
15,88
14,29
14,56
143
130
138
104

5202
1167
1159
1209
1218
422
418
405
393
2,76
2,77
2,98
3,10
200780
199390
207920
209510
116
135
145
109
687
720
806
930
45
45
56
62
15,31
15,91
14,33
14,89
116
135
145
109

5602
1223
1217
1266
1274
439
437
426
416
2,79
2,79
2,97
3,06
210330
209370
217720
219210
109
84
104
72
746
784
890
987
60
52
66
66
12,45
15,02
13,55
15,05
109
84
104
72

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

6002
1305
1279
1326
1318
453
449
440
434
2,88
2,85
3,01
3,04
224450
220070
228110
226710
125
115
124
78
800
836
942
1002
64
56
69
66
12,56
15,00
13,56
15,27
125
115
124
78

6402
1347
1342
1387
1362
472
461
454
451
2,85
2,91
3,06
3,02
231640
230760
238500
234210
133
112
113
81
803
891
995
1007
64
59
73
66
12,60
15,01
13,57
15,34
133
112
113
81

6503
6703
6903
7203
8403
9603
2028
1459
1502
1659
1705
1838
1434
1500
1599
1684
1491
1554
1667
1753
1478
492
520
557
583
659
704
491
511
569
588
478
499
550
570
472
2,97
2,89
2,98
2,92
2,79
2,88
2,92
2,93
2,81
2,86
3,12
3,12
3,03
3,07
3,13
250990 258340 285350 293260 316150 348840
246660 257930 274970 289650
256480 267340 286650 301470
254300
112
127
132
143
108
135
110
121
121
130
117
119
137
138
105
894
899
1043
1047
1133
1260
904
966
995
1048
1015
1102
1130
1188
1064
59
59
70
70
77
85
55
62
64
67
72
79
81
85
72
15,08 15,17 15,00 15,04 14,72
14,87
16,33 15,57 15,47
15,62
14,19 13,90 13,90
13,96
14,87
135
112
127
132
143
108
110
121
121
130
117
119
137
138
105

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C;
Coil circuit glycol 30%; Plant circuit glycol 0%

Electrical data
(1)

Total input current


(Chiller)

(1)
(1)
(1)
(1)

Total input current


(Free cooling glycol free)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

BA
BE
BU
BN
BA
BE
BU
BN
BA
BE
BU
BN
BA
BE
BU
BN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
(1)

Quantity

(1)
(1)
(1)

BA
BE
BU
BN

Standard Fans
Quantity

Air flow rate

BA
BE
BU
BN
BA
BE
BU
BN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

581
555
564
544
79
64
100
68
702
725
725
739
876
900
900
914

614
601
605
570
87
64
100
86
750
764
764
805
949
964
964
1004

655
632
639
600
87
68
108
91
789
818
818
854
972
1001
1001
1037

704
678
682
639
87
68
108
95
832
861
861
906
1127
1156
1156
1201

733
708
718
677
114
80
126
100
903
920
922
958
1202
1219
1221
1257

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
2

1
1
1
2

1
1
1
2

1
2
2
2

16
20
20
22
232000
224000
290000
246400

18
20
20
26
261000
224000
290000
291200

18
22
22
28
261000
246400
319000
313600

18
22
22
30
261000
246400
319000
336000

20
24
24
32
290000
268800
348000
358400

101
95
102
95

102
95
102
96

102
95
102
96

761
796
732
755
746
774
708
740
121
121
86
91
134
141
100
100
951
985
964
1008
965
1008
992
1026
1328
1325
1341
1348
1342
1348
1369
1366
twin-screw
2
3
2
3
R134a
shell and tube
1
1
2
2
2
2
2
2
axial
22
22
26
28
26
28
32
32
319000 319000
291200 313600
377000 406000
358400 358400

821
804
812
771
116
84
139
109
1005
1026
1030
1064
1094
1115
1119
1153

872
832
846

945
924
926

986
945
954

1100

1198

116
94
152

135
98
156

135
102
163

149

165

1053
1089
1093

1152
1171
1174

1192
1218
1221

1335

1455

1121
1156
1160

1229
1247
1250

1252
1278
1281

1515

1639

3
3

3
3

3
3

3
3

3
3

3
3

2
2
2
2

2
2
2

2
2
2

2
2
2

24
24
28
28
30
34
28
30
30
32
28
30
30
32
34
348000 348000 406000 406000 435000 493000
313600 336000 336000 358400
406000 435000 435000 464000
380800

Sound data
Sound power
Electric power supply

320

BA
BE
BU
BN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

102
102
96
96
102
103
97
97
400V/3/50Hz

102
96
103
97

102
96
103
97

103
96
103
97

103
96
104

103
96
104

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

103
97
104

104

104

Technical data
Mod NSM Free cooling PLUS glycol free
GA
kW
GE
kW
Cooling capacity
GU
kW
GN
kW
GA
kW
GE
kW
Input power
GU
kW
GN
kW
GA W/W
GE W/W
EER
GU W/W
GN W/W
GA
l/h
GE
l/h
Water flow rate
GU
l/h
GN
l/h
GA
kPa
GE
kPa
Total pressure drops
GU
kPa
GN
kPa
GA
kW
GE
kW
Cooling capacity
GU
kW
GN
kW
GA
kW
GE
kW
Input power
GU
kW
GN
kW
GA W/W
GE W/W
EER
GU W/W
GN W/W
GA
kPa
GE
kPa
Total pressure drops
GU
kPa
GN
kPa

1402
306
317
327
325
104
107
106
104
2,95
2,97
3,08
3,11
52600
54470
56230
55920
72
63
66
54
279
258
287
301
18
15
19
18
15,24
16,92
14,95
16,68
72
63
66
54

1602
349
363
377
375
119
125
123
120
2,94
2,91
3,07
3,12
60090
62460
64790
64530
94
75
80
64
287
265
299
318
18
15
19
20
15,70
17,42
15,56
16,16
94
75
80
64

2602
395
414
428
423
138
139
138
136
2,86
2,99
3,11
3,12
67940
71290
73540
72740
99
83
87
66
296
316
356
372
18
20
25
26
16,17
16,16
14,49
14,35
99
83
87
66

2002
447
470
489
484
160
161
157
155
2,79
2,91
3,10
3,11
76940
80760
84070
83170
71
77
82
82
310
334
380
384
18
20
27
26
16,90
16,97
14,16
14,82
71
77
82
82

2202
502
504
528
522
171
181
175
173
2,94
2,79
3,02
3,02
86360
86710
90740
89790
89
88
95
95
377
337
388
394
25
20
27
27
15,29
17,13
14,44
14,81
89
88
95
95

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

2352
519
545
565
557
183
185
182
180
2,84
2,94
3,11
3,09
89280
93810
97250
95770
95
87
92
91
381
401
457
447
25
26
32
30
15,44
15,37
14,23
15,05
95
87
92
91

2502
553
564
586
577
197
198
193
192
2,81
2,85
3,03
3,01
95050
97020
100720
99190
107
92
98
97
385
405
461
452
25
26
32
30
15,59
15,52
14,37
15,21
107
92
98
97

2652
597
614
635
623
205
208
204
203
2,91
2,96
3,10
3,07
102710
105580
109150
107170
106
102
104
78
461
456
516
516
32
30
37
33
14,37
15,36
14,07
15,72
106
102
104
78

2802
645
641
664
652
223
223
218
217
2,89
2,87
3,04
3,00
111010
110230
114220
112100
116
108
87
85
470
461
541
527
32
30
37
33
14,66
15,51
14,62
16,04
116
108
87
85

3002
674
670
692
680
238
239
231
231
2,83
2,80
2,99
2,94
115990
115210
118970
116890
99
89
94
92
489
479
546
532
32
30
37
33
15,13
15,96
14,77
16,20
99
89
94
92

3202
722
711
732
720
257
258
246
246
2,81
2,76
2,98
2,92
124160
122270
125990
123890
93
93
86
85
494
488
562
542
32
30
37
33
15,28
16,27
15,16
16,44
93
93
86
85

3402
808
791
820
807
273
275
266
267
2,96
2,88
3,08
3,02
138940
135990
141090
138810
80
79
84
83
573
551
627
605
37
33
41
39
15,46
16,73
15,32
15,35
80
79
84
83

3602
865
843
885
883
299
301
291
286
2,89
2,80
3,04
3,09
148770
145080
152170
151850
92
90
98
99
579
556
639
665
37
33
41
42
15,62
16,89
15,62
15,77
92
90
98
99

3902
947
921
962
955
322
324
315
310
2,94
2,84
3,06
3,08
162860
158470
165430
164280
111
108
116
105
647
614
692
723
41
36
45
45
15,81
17,18
15,49
16,06
111
108
116
105

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C;
Coil circuit glycol 30%; Plant circuit glycol 0%

Electrical data
(1)

Total input current


(Chiller)

(1)
(1)
(1)
(1)

Total input current


(Free cooling glycol free)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

GA
GE
GU
GN
GA
GE
GU
GN
GA
GE
GU
GN
GA
GE
GU
GN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
GA
GE
(1) GU
(1) GN
(1)

Quantity

(1)

Standard Fans
Quantity

Air flow rate

GA
GE
GU
GN
GA
GE
GU
GN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

184
179
187
176
36
23
38
27
250
251
251
260
271
272
272
281

208
208
213
201
36
23
38
30
278
279
279
290
313
314
314
326

233
225
234
220
36
30
48
40
305
317
317
332
356
368
368
383

271
263
269
255
37
30
52
40
338
351
354
365
394
407
410
421

294
298
300
286
48
30
52
41
384
384
388
400
429
430
433
445

315
308
316
300
48
40
62
45
405
420
420
430
476
491
491
501

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

8
8
8
8
10
8
8
10
10
10
8
8
10
10
10
10
10
12
12
12
109600 109600 109600 109600 137000
85600 85600 107000 107000 107000
109600 109600 137000 137000 137000
107000 107000 128400 128400 128400

10
12
12
14
137000
128400
164400
149800

339
355
329
345
335
356
320
338
48
62
40
45
62
71
45
50
427
466
442
476
441
476
451
485
494
535
509
545
508
545
518
554
twin-screw
2
2
2
2
R134a
shell and tube
1
1
1
1
1
1
1
1
axial
10
12
12
14
12
14
14
16
137000 164400
128400 149800
164400 191800
149800 171200

382
369
377
360
62
45
71
50
491
501
501
510
545
555
555
564

405
393
396
381
62
46
71
50
491
501
501
510
546
556
555
564

433
421
418
404
62
46
71
50
491
501
501
510
546
556
556
564

456
443
447
431
71
50
79
60
549
558
558
572
680
688
688
703

492
480
482
457
71
50
79
64
597
606
606
628
719
728
728
751

536
523
528
501
79
54
87
68
654
662
662
691
849
858
857
886

2
2

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

12
14
14
16
164400
149800
191800
171200

12
14
14
16
164400
149800
191800
171200

12
14
14
16
164400
149800
191800
171200

14
16
16
18
191800
171200
219200
192600

14
16
16
20
191800
171200
219200
214000

16
18
18
22
219200
192600
246600
235400

100
93
100
93

100
93
100
93

100
93
100
93

100
94
101
94

100
94
101
95

101
95
102
95

Sound data
Sound power
Electric power supply

GA
GE
GU
GN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

98
91
98
92

98
91
98
92

98
92
99
92

98
92
99
92

99
92
99
93

99
93
100
93

99
100
93
93
100
100
93
93
400V/3/50Hz

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

321

Technical data
Mod NSM Free cooling PLUS glycol free
GA
kW
GE
kW
Cooling capacity
GU
kW
GN
kW
GA
kW
GE
kW
Input power
GU
kW
GN
kW
GA W/W
GE W/W
EER
GU W/W
GN W/W
GA
l/h
GE
l/h
Water flow rate
GU
l/h
GN
l/h
GA
kPa
GE
kPa
Total pressure drops
GU
kPa
GN
kPa
GA
kW
GE
kW
Cooling capacity
GU
kW
GN
kW
GA
kW
GE
kW
Input power
GU
kW
GN
kW
GA W/W
GE W/W
EER
GU W/W
GN W/W
GA
kPa
GE
kPa
Total pressure drops
GU
kPa
GN
kPa

4202
989
988
1025
999
351
344
335
337
2,82
2,87
3,06
2,97
170060
169860
176350
171790
120
124
118
114
653
683
784
730
41
42
52
45
15,96
16,12
14,95
16,22
120
124
118
114

4502

4802

5202

5602

6002

6402

1074
1042
1088
1093
370
375
362
353
2,90
2,78
3,00
3,09
184760
179210
187150
187940
130
126
135
102
730
694
792
853
45
42
52
56
16,25
16,35
15,09
15,28
130
126
135
102

1119
1127
1174
1156
397
395
383
373
2,82
2,86
3,06
3,10
192490
193870
201920
198770
140
128
137
103
737
752
854
903
45
45
56
59
16,40
16,63
15,19
15,21
140
128
137
103

1156
1148
1201
1212
428
424
410
396
2,70
2,71
2,93
3,06
198900
197450
206550
208410
114
132
143
109
744
759
863
978
45
45
56
63
16,56
16,78
15,34
15,63
114
132
143
109

1213
1207
1258
1268
444
442
431
420
2,73
2,73
2,92
3,02
208590
207550
216360
218050
107
83
103
71
797
819
941
1043
49
52
66
66
16,36
15,67
14,33
15,88
107
83
103
71

1295
1269
1319
1311
458
454
444
438
2,83
2,79
2,97
3,00
222770
218320
226790
225490
123
114
123
77
857
875
998
1051
52
56
70
66
16,33
15,67
14,35
16,02
123
114
123
77

1336
1332
1379
1354
478
467
458
455
2,79
2,85
3,01
2,97
229830
229100
237230
232920
131
111
112
81
865
931
1055
1053
52
59
73
66
16,49
15,67
14,38
16,04
131
111
112
81

Cooling mode
Evaporator water temperature (in/out) 12C/7C; Outdoor air temperature 35C

6503

6703 6903 7203 8403 9603


2013
1448
1490
1647
1692
1823
1422
1488
1583
1668
1482
1545
1656
1742
1470
498
527
564
591
667
712
498
517
577
597
483
504
556
577
477
2,83
2,91
2,83
2,92
2,86
2,73
2,86
2,88
2,74
2,80
3,07
3,07
2,98
3,02
3,08
249020 256220 283280 291010 313530 346260
244540 255930 272310 286960
254900 265810 284790 299560
252840
133
111
120
130
140
106
111
122
122
131
116
118
135
137
104
964
970
1118
1125
1210
1355
951
1020
1039
1097
1080
1165
1184
1254
1113
85
59
59
70
70
77
55
62
64
67
72
76
76
84
72
16,25 16,35 16,07 16,17 15,72
15,97
17,16 16,44 16,15
16,35
15,10 15,42 15,66
14,92
15,54
133
111
120
130
140
106
111
122
122
131
116
118
135
137
104

Cooling in freecooling glycol free (100%)


Evaporator water temperature (in) 15C; Outdoor air temperature 2C;
Coil circuit glycol 30%; Plant circuit glycol 0%

Electrical data
(1)

Total input current


(Chiller)

(1)
(1)
(1)
(1)

Total input current


(Free cooling glycol free)

(1)
(1)
(1)
(1)

Maximum current FLA

(1)
(1)
(1)
(1)

Peak current LRA

(1)
(1)
(1)

GA
GE
GU
GN
GA
GE
GU
GN
GA
GE
GU
GN
GA
GE
GU
GN

Compressors
Compressors
Circuits
Refrigerant gas
Heat exchanger
GA
GE
(1) GU
(1) GN
(1)

Quantity

(1)

Standard Fans
Quantity

Air flow rate

GA
GE
GU
GN
GA
GE
GU
GN

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
type
n
n
type
type
n
n
n
n
type
n
n
n
n
m3/h
m3/h
m3/h
m3/h

588
561
569
550
79
64
101
68
702
725
725
739
876
899
899
913

621
609
611
575
87
64
101
86
749
764
764
805
949
963
963
1004

662
640
645
606
87
68
108
91
788
817
817
853
971
1000
1000
1036

713
687
688
644
87
68
108
95
831
860
860
905
1126
1155
1155
1200

741
717
725
682
95
80
126
100
883
920
921
957
1182
1219
1220
1256

2
2

2
2

2
2

2
2

2
2

1
1
1
1

1
1
1
2

1
1
1
2

1
1
1
2

1
2
2
2

16
20
20
22
219200
214000
274000
235400

18
20
20
26
246600
214000
274000
278200

18
22
22
28
246600
235400
301400
299600

18
22
22
30
246600
235400
301400
321000

20
24
24
32
274000
256800
328800
342400

101
95
102
95

102
95
102
96

102
95
102
96

102
96
102
97

102
96
103
97

769
805
740
763
752
780
714
746
102
102
86
91
134
141
100
100
931
965
964
1007
964
1007
991
1025
1308
1305
1341
1347
1341
1347
1368
1365
twin-screw
2
2
2
2
R134a
shell and tube
1
1
2
2
2
2
2
2
axial
22
22
26
28
26
28
32
32
301400 301400
278200 299600
356200 383600
342400 342400

830
814
819
778
116
84
139
109
1004
1026
1029
1064
1093
1114
1117
1152

882
842
854

956
937
936

998
957
963

1112

1211

116
94
147

135
98
147

135
102
162

149

165

1052
1088
1086

1151
1170
1164

1190
1217
1218

1334

1453

1120
1156
1153

1228
1246
1240

1250
1277
1278

1514

1637

3
3

3
3

3
3

3
3

3
3

3
3

2
2
2
2

2
2
2

2
2
2

2
2
2

24
24
28
28
30
34
28
30
30
32
28
30
30
32
34
328800 328800 383600 383600 411000 465800
299600 321000 321000 342400
383600 411000 411000 438400
363800

Sound data
Sound power
Electric power supply

322

GA
GE
GU
GN

dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

102
96
103
97

102
96
103
97
400V/3/50Hz

103
96
103
97

103
96
104

103
96
104

(1) The electric data is of the versions without integrated hydronic kit.
Sound powerAermec determines sound power values in agreement with the Standard UNI EN ISO 9614-2, in compliance with that requested
by the Eurovent certification.
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

103
97
104

104

104

Dimensions and Weights

Mod. NSM Free cooling glycol free and Free cooling plus glycol free
Vers
1402
1602
Height
(mm)
A
All
2450
2450
Width
(mm)
B
All
2200
2200
A
5160
5160
E
5160
5160
Length
(mm)
C
U
5160
5160
N
6350
6350

Height
Width

(mm)
(mm)

A
B

Length

(mm)

Height
Width

(mm)
(mm)

A
B

Length

(mm)

Height
Width

(mm)
(mm)

A
B

Length

(mm)

1802
2450
2200
5160
6350
6350
7140

2002
2450
2200
5160
6350
6350
7140

2202
2450
2200
6350
6350
6350
7140

2352
2450
2200
6350
7140
7140
8330

2502
2450
2200
6350
7140
7140
8330

2652
2450
2200
7140
8330
8330
9520

Vers
All
All
A
E
U
N

2802
2450
2200
7140
8330
8330
9520

3002
2450
2200
7140
8330
8330
9520

3202
2450
2200
7140
8330
8330
9520

3402
2450
2200
8330
9520
9520
10710

3602
2450
2200
8330
9520
9520
11900

3902
2450
2200
9520
10710
10710
13090

4202
2450
2200
9520
11900
11900
13090

4502
2450
2200
10710
11900
11900
15470

Vers
All
All
A
E
U
N

4802
2450
2200
10710
13090
13090
16660

5202
2450
2200
10710
13090
13090
17850

5602
2450
2200
11900
14280
14280
19040

6002
2450
2200
13090
15470
15470
19040

6402
2450
2200
13090
16660
16660
19040

6503
2450
2200
14280
16660
16660
20230

6703
2450
2200
14280
17850
17850

6903
2450
2200
16660
17850
17850

Vers
All
All
A
E
U
N

7203
2450
2200
16660
19040
19040

8403
2450
2200
17850

9603
2450
2200
20230

For transport reasons, units with depth greater than 13090 mm are shipped separately. For further information, refer to the technical and/or
installation manual.

323

Cod.: SNSMBGUY.00 / 1503

NS
1251/7203

Chillers with freecooling glycolfree HWT


Air/Water outdoor installation
Axial fans and twin-rotor screw compressor
Cooling capacity 2431554kW

glycolfree
HWT

R134a
Designed for

DATA CENTERS &


PROCESS COOLING
Applications

HIGH EFFICIENCY VERSION


HIGH EFFICIENCY EVEN AT PART LOAD
OPERATES TO 46 C AMBIENT
WATER PRODUCTION UP TO 30 C
OPTION VERSION WITH BUILT-IN HYDRONIC KIT

Characteristics
Chillers with freecooling glycolfree
Version
NS_BA High efficiency version
NS_BE High efficiency low noise version
Operational limits (1)
- max. external air temperature 46C
1/3 refrigerant circuits
High efficiency, low noise screw compressors
with modulating capacity control from 40 to
100%. (25 to 100% with electronic expansion valve option)
Shell and tube evaporator optimised for
refrigerant R134a
Pressure switch as standard supply
An intermediate plate heat exchanger pro-

vides two circuits: a glycol circuit, where


glycol is added to protect the chiller's coils
from freezing, and the chilled water circuit
without glycol.
The glycol circuit includes as standard:
- Intermediate plate heat exchanger
- Circulation pump
- Expansion vessel
- Flow switch
- Low pressure switch
- Gauge
- Safety pressure valve
Partial heat recovery (option) desuperheater
Option integrated hydronic mudule, it consist of 1
or 2 pumps and 2 exspansion tanks (25l.)
Axial fans for extremely quiet operation

Modulating capacity control microprocessor


system
Multilingual display panel
Metal control panel with anti-corrosion polyester paint
DCPX as standard: fan speed control by
means of phase-cut controller
The low nois version "E" is equipped:
- Compressor acoustical enclosure
- Hot gas discharge muffler.

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and

324

remote control max. 18 units in RS485 netKDI: 20 mm doubled thickness evaporator


work with integrated GPRS modem;
insulation. Provides stand-still protection
PRV3: Remote control of the chiller operating
down to -20C. Must be ordered in conjuncfunctions.
tion with options KRS and KRSDES heaters.
MULTICHILLER: Control system for multiple RIFNS: Power factor correction. Connected in
parallel installed constant flow chillers proparallel to the motor allowing about 10%
viding individual chiller on/off and control
reduction of input current.
capability.
GP: Protective grille. Condenser coil external
AVX: Spring anti-vibration mounts.
protection against accidental or hail damage.
AK: ACOUSTIC KIT
(only for Versions E)
Accessories factory fitted only
This accessory allows further sound reduc KRS: (compulsory accessory). Evaporator
tion. Must be requested at time of order and
trace heating.
is available factory fitted only.
KRSDES: (compulsory accessory) Evaporator
and heat recovery exchangers trace heating.

Compatibility of accessories
Mod. NS
AER485P1
AERWEB300
PRV3
MULTICHILLER
Accessories factory fitted only
KRS
(1)
KRS_DES
(2)
KDI
(3)
RIFNS
GP300M
GP400M
GP500M
GP300B
GP400B
GP500B
GP300M+300M
AK
(4)

vers.
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
BE

AER485P1
AERWEB300
PRV3
MULTICHILLER
Accessories factory fitted only
KRS
(1)
KRS_DES
(2)
KDI
(3)
RIFNS
GP300M+300M
GP300M+400M
GP400M+400M
GP400M+500M
GP500M+500M
GP400M+400M+500M
GP400M+500M+500M
GP500M+500M+400M
AK
(4)

all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
BE

Spring anti-vibration mounts


AVX

1251
(x1)

1401
(x1)

1601
(x1)

1801
(x1)

2101
(x1)

2401
(x1)

1402
(x2)

1602
(x2)

1802
(x2)

2002
(x2)

2202
(x2)

2352
(x2)

2502
(x2)

2652
(x2)

2802
(x2)

3002
(x2)

KRS10 KRS10 KRS11 KRS10 KRS11 KRS11 KRS11 KRS11 KRS10 KRS10 KRS11 KRS11 KRS11 KRS11 KRS11 KRS13
KRS10DES KRS10DES KRS11DES KRS11DES KRS11DES KRS11DES KRS19DES KRS19DES KRS18DES KRS18DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS13DES
01
01
02
03
04
04
06
06
06
06
08
08
08
08
08
01+02

1251F 1401F 1601F 1801

2101

2401

1402

1602

1802

2002

2202

2352

2502

2652

2802 3002F

3202
(x2)

3402
(x2)

3602
(x2)

3902
(x2)

4202
(x2)

4502
(x2)

4802
(x2)

5002
(x2)

5202
(x2)

5402
(x2)

5702
(x2)

6003
(x3)

6303
(x3)

6603
(x3)

6903
(x3)

7203
(x3)

KRS14 KRS13 KRS12 KRS13 KRS13 KRS14 KRS14 KRS14 KRS14 KRS14 KRS14 KRS15 KRS16 KRS16 KRS17 KRS17
KRS14DES KRS13DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES
02 (x2)
02+03
03 (x2)
03+04
03+04
04 (x2)
04 (x2)
04+05
05 (x2)
05 (x2)
05 (x2) 03 (x2)+04 03+04 (x2) 03+04 (x2) 04 (x3)
04 (x3)

3202F 3402F 3602

3902

4202

4502

4802

5002

5202

5402

5702

6003

6303

6603

6903

7203

1251

1401

1601

1801

2101

2401

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

3202

3402

3602

3902

4202

4502

4802

5002

5202

5402

5702

6003

6303

6603

6903

7203

(1) Accessory (compulsory) comes standard with the electrical heater for evaporator
(2) Accessory (compulsory) comes standard with the electrical heater for evaporator and desuperheater
(3) Accessory KDI must always be combined with the KRS and KRSDES heating elements
(4) The accessory is only available for the low noise version "BE"
(x2) the number in brackets indicates the quantity to order

325

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2
3,4,5,6

7
W
8
B
9

10
A
E
11

R
S
V
12

M
J
13

8
14-15
00
PA
PB
PC
PD
PE
PF
PG
PH
PJ
PK

Code
NS
Size
1251-1401-1601-1801-2101-2401 (single module 1 circuits)
1402-1602-1802-2002-2202-2352-2502-2652-2802 (single module 2 circuits)
3002-3202-3402-3602-3902-4202-4502-4802-5002-5202-5402-5702 (double module 2 circuits)
6003-6303-6603-6903-7203 (three module 3 circuits)
Expansion valve:
Electronic expansion valve, leaving water temperature from +5C up to +30C
Model
Frecooling Glycolfree
Heat ecovery
Without recovery
Version
High efficiency
High efficiency in low noise operation
Coil
In aluminium
In copper
In tinned copper
In painted aluminium-copper (epoxy paint)
Fans
Standard
Increased
Inverter
Power supply
400V/3/50Hz with fuses
400V/3/50Hz with circuit breakers
Hydronic kit
Without hydronic kit
Hydronic pump (Pump A)
Hydronic pump (A Pump and reserve pump) (5)
Hydronic pump (C Pump)
Hydronic pump (C Pump and reserve pump) (5)
Hydronic pump (E Pump)
Hydronic pump (E Pump and reserve pump) (5)
Hydronic pump (G Pump)
Hydronic pump (G Pump and reserve pump) (5)
Hydronic pump (J Pump)
Hydronic pump (J Pump and reserve pump) (5)

(5) Not available for size 12511601/30023402


Pump assembly option not available in sizes 1402, 1602, 2002

326

Technical Data
Mod NS freecooling Glycol free
BA
BE
BA
BE
BA
BE
BA
BE
BA/BE
BA
BE
BA
BE
BA
BE
BA
BE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa

1251
272
243
91
93
2,99
2,61
265
251
14,0
18,9
17,9
8,6
8,7
46780
41800
78
70

1401
304
282
104
105
2,92
2,69
306
286
14,0
21,9
20,4
7,2
7,8
52290
48500
80
70

1601
338
322
115
117
2,94
2,75
331
307
14,0
23,6
21,9
6,6
7,5
58140
55380
69
59

1801
408
372
144
148
2,83
2,51
398
367
19,8
20,1
18,5
8,1
8,7
70180
63980
90
76

2101
465
415
157
161
2,96
2,58
459
424
25,3
18,1
16,8
8,6
9,1
79980
71380
88
75

2401
518
471
177
183
2,93
2,57
514
472
25,5
20,2
18,5
7,6
8,4
89100
81010
103
87

1402
285
257
103
105
2,77
2,45
304
285
14,0
21,7
20,4
7,0
6,1
49020
44200
76
67

1602
324
295
119
121
2,72
2,44
340
314
14,0
24,3
22,4
6,0
6,8
55730
50740
88
75

Cooling
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Freecooling Glycolfree (100%)
Evaporator water temperature (in) 25C; Primary circuit glycol 30%; secondary system circuit glycol 0%

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Glycolfree)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1) BA
(1)
BE
(1) BA/BE
BA/BE
BA/BE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

BA
BE

Air flow rate (Glycolfree)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Glycolfree)


Power supply

1401

1601

1801

2101

2401

1402

1602

160
164
28
159
281

180
182
28
182
322

196
199
28
197
376

238
245
40
228
438

267
274
51
259
446

299
309
51
292
492

179
182
28
188
288

205
208
28
210
304

two screw two screw two screw two screw two screw two screw two screw two screw
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
6
102000
70000
102000

axial
6
102000
78000
102000

62
54
62
94
86
94
400V/3

63
55
63
95
87
95
400V/3

kPa
BA
BE

Sound pressure (Glycolfree)


Sound power (Chiller)

A
A
A
A
A

1251

BA
BE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


1
1
1
refer to the technical manual

axial
axial
axial
axial
6
8
10
10
102000
136000
170000
170000
87000
100000
112000
127000
102000
136000
170000
170000
refer to the technical manual
refer to the technical manual

axial
6
102000
74000
102000

axial
6
102000
80000
102000

65
57
65
97
89
97
400V/3

64
56
64
96
88
96
400V/3

65
57
65
97
89
97
400V/3

65
57
65
97
89
97
400V/3

66
57
66
98
90
98
400V/3

66
58
66
98
90
98
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

327

Technical Data
Mod NS freecooling Glycolfree
BA
BE
BA
BE
BA
BE
BA
BE
BA/BE
BA
BE
BA
BE
BA
BE
BA
BE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa

1802
411
382
110
114
3,74
3,35
411
382
19,8
20,8
19,3
7,3
7,8
70692
65704
97
84

2002
445
419
118
122
3,77
3,43
445
419
25,3
17,6
16,6
8,1
7,9
76540
72068
93
83

2202
472
436
122
126
3,87
3,46
472
436
25,3
18,7
17,2
8,4
9,0
81184
74992
89
76

2352
493
461
133
139
3,71
3,32
493
461
25,4
19,4
18,1
8,1
8,5
84796
79292
95
83

2502
520
483
143
150
3,64
3,22
520
483
25,5
20,4
18,9
7,5
8,1
89440
83076
103
89

2652
550
509
155
164
3,55
3,10
550
509
27,1
20,3
18,8
7,0
7,7
94600
87548
109
94

2802
574
543
167
177
3,44
3,07
574
543
27,2
21,1
20,0
6,6
7,2
98728
93396
118
105

3002
637
593
171
180
3,73
3,29
637
593
28,0
22,8
21,2
6,9
7,6
109564
101996
74
64

Cooling
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Freecooling Glycolfree (100%)
Evaporator water temperature (in) 25C; Primary circuit glycol 30%; secondary system circuit glycol 0%

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Glycolfree)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1) BA
(1)
BE
(1) BA/BE
BA/BE
BA/BE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

BA
BE

Air flow rate (Glycolfree)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Glycolfree)


Power supply

2002

2202

2352

2502

2652

2802

3002

225
230
40
244
332

261
266
51
264
377

288
286
51
276
389

305
308
51
293
415

322
331
51
310
432

344
349
54
333
473

366
364
54
356
496

376
381
56
379
558

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
8
136000
96000
136000

axial

axial

170000
124500
170000

65
57
65
97
89
97
400V/3

66
57
66
98
90
98
400V/3

kPa
BA
BE

Sound pressure (Glycolfree)


Sound power (Chiller)

A
A
A
A
A

1802

BA
BE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


1
1
1
refer to the technical manual

axial

axial

170000
170000
170000
170000
120000
123000
130000
130000
170000
170000
170000
170000
refer to the technical manual
refer to the technical manual

170000
140000
170000

204000
165000
204000

66
58
66
98
90
98
400V/3

67
59
67
99
91
99
400V/3

66
58
66
99
91
99
400V/3

axial

66
58
66
98
90
98
400V/3

axial

66
58
66
98
90
98
400V/3

axial

67
59
67
99
91
99
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

328

Technical Data
Mod NS freecooling Glycolfree
BA
BE
BA
BE
BA
BE
BA
BE
BA/BE
BA
BE
BA
BE
BA
BE
BA
BE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water Blow rate
Total pressure drop

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa

3202
662
614
176
188
3,76
3,27
662
614
28,0
23,6
21,9
6,6
7,5
113864
105608
69
59

3402
729
674
189
200
3,86
3,37
729
674
33,8
21,6
19,9
7,4
8,1
125388
115928
79
68

3602
796
734
202
212
3,94
3,46
796
734
39,6
20,1
18,5
8,1
8,7
136912
126248
89
76

3902
857
791
214
223
4,00
3,55
857
791
45,1
19,0
17,5
8,4
8,9
147404
136052
89
76

4202
912
839
230
241
3,97
3,48
912
839
45,3
20,1
18,5
7,9
8,5
156864
144308
97
82

4502
973
896
242
252
4,02
3,56
973
896
50,8
19,2
17,6
8,1
8,7
167356
154112
96
81

4802
1028
944
258
270
3,98
3,50
1028
944
51,0
20,2
18,5
7,6
8,4
176816
162368
103
87

5002
1087
1003
281
296
3,87
3,39
1087
1003
51,0
21,3
19,7
6,7
7,6
186964
172516
100
85

Cooling
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Freecooling Glycolfree (100%)
Evaporator water temperature (in) 15 C; Primary circuit glycol 30%; secondary system circuit glycol 0%

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Glycolfree)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1) BA
(1)
BE
(1) BA/BE
BA/BE
BA/BE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

BA
BE

Air flow rate (Glycolfree)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Glycolfree)


Power supply

3402

3602

3902

4202

4502

4802

5002

314
326
56
394
573

336
348
68
425
635

358
370
79
456
666

375
386
90
487
674

413
426
91
520
720

430
442
102
551
751

468
482
102
584
784

496
514
102
601
920

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
12
204000
174000
204000

axial
14
238000
187000
238000

67
59
67
100
92
100
400V/3

67
59
67
100
92
100
400V/3

kPa
BA
BE

Sound pressure (Glycolfree)


Sound power (Chiller)

A
A
A
A
A

3202

BA
BE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


2
2
2
refer to the technical manual

axial
axial
axial
axial
16
18
18
20
272000
306000
306000
340000
200000
212000
227000
239000
272000
306000
306000
340000
refer to the technical manual
refer to the technical manual

axial
20
340000
254000
340000

axial
20
340000
254000
340000

67
59
67
100
92
100
400V/3

68
60
68
101
93
101
400V/3

69
61
69
102
94
102
400V/3

68
60
68
101
93
101
400V/3

68
60
68
101
93
101
400V/3

68
60
68
101
93
101
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

329

Technical Data
Mod NS freecooling Glycolfree
BA
BE
BA
BE
BA
BE
BA
BE
BA/BE
BA
BE
BA
BE
BA
BE
BA
BE

Cooling capacity
Total input power
EER
Cooling capacity
Total input power
EER
External air temperature
total freecooling
Water flow rate
Total pressure drop

kW
kW
kW
kW
W/W
W/W
kW
kW
kW
W/W
W/W
C
C
l/h
l/h
kPa
kPa

5202
1146
1062
304
322
3,77
3,30
1146
1062
51,0
22,5
20,8
6,1
6,9
197112
182664
94
81

5402
1205
1113
332
354
3,63
3,14
1205
1113
51,0
23,6
21,8
5,6
6,4
207260
191436
98
84

5702
1264
1164
360
386
3,51
3,02
1264
1164
51,0
24,8
22,8
5,0
5,9
217408
200208
104
88

600
1310
1206
331
347
3,96
3,48
1310
1206
65,1
20,1
18,5
7,9
8,6
225320
207432
94
80

6303
1371
1263
343
358
4,00
3,53
1371
1263
70,6
19,4
17,9
8,1
8,7
235812
217236
94
80

6603
1426
1311
359
376
3,97
3,49
1426
1311
70,8
20,1
18,5
7,8
8,5
245272
225492
97
82

6903
1487
1368
371
387
4,01
3,53
1487
1368
76,3
19,5
17,9
7,9
8,6
255764
235296
98
83

7203
1542
1416
387
405
3,98
3,50
1542
1416
76,5
20,2
18,5
7,6
8,4
265224
243552
103
87

Cooling
Evaporator water temperature (in/out) 12C/7C; External air temperature 35C
Freecooling Glycolfree (100%)
Evaporator water temperature (in) 25C; Primary circuit glycol 30%; secondary system circuit glycol 0%

GENERAL DATA
Electrical data
Total input current (Chiller)
Total input current (Glycolfree)
Maximum current (FLA)
Starting current (LRA)
Compressors

(1) BA
(1)
BE
(1) BA/BE
BA/BE
BA/BE

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger

(2)

Exchanger
hydraulic connections (in/out)
Fans standard
Fans
Air flow rate (Chiller)

BA
BE

Air flow rate (Glycolfree)


Hydronic kit system side
Useful static pressure
Sound data
Sound pressure (Chiller)

Sound power (Glycolfree)


Power supply

5402

5702

6003

6303

6603

6903

7203

524
546
102
618
937

568
596
102
657
1001

612
646
102
696
1040

592
611
130
748
948

609
627
141
779
979

647
667
142
812
1012

664
683
153
843
1043

702
723
153
876
1076

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
3
3
3
3
3
2
2
2
3
3
3
3
3
40-100
40-100
40-100
40-100
40-100
40-100
40-100
40-100
R134a
R134a
R134a
R134a
R134a
R134a
R134a
R134a

type
n

type
n
m3/h
m3/h
m3/h

axial
20
340000
254000
340000

axial
20
340000
254000
340000

69
63
69
102
94
102
400V/3

69
63
69
102
94
102
400V/3

kPa
BA
BE

Sound pressure (Glycolfree)


Sound power (Chiller)

A
A
A
A
A

5202

BA
BE

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
V/ph/Hz

Shell and tube


3
3
3
refer to the technical manual

axial
axial
axial
axial
20
26
28
28
340000
442000
476000
476000
254000
327000
339000
354000
340000
442000
476000
476000
refer to the technical manual
refer to the technical manual

axial
30
510000
366000
510000

axial
30
510000
381000
510000

69
63
69
102
94
102
400V/3

69
63
69
103
95
103
400V/3

69
63
69
103
95
103
400V/3

69
62
69
102
94
102
400V/3

69
62
69
102
94
102
400V/3

70
63
70
103
95
103
400V/3

(1) The electrical data of the versions without hydronic module integrated
(2) Standard expansion valve
Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

330

Dimensions (mm)

NS12512401
(single module 1 circuits)

NS14022802
(single module 2 circuits)

NS30025702
(double module 2 circuits)

NS60037203
(three module 3 circuits)

A
A

C
B

B
C

C
B
B

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
All
All
All
All

1251
2450
2200
3780
3596

1401
2450
2200
3780
3610

1601
2450
2200
3780
3968

1801
2450
2200
4770
4779

2101
2450
2200
5750
5708

2401
2450
2200
5750
5729

1402
2450
2200
3780
3796

1602
2450
2200
3780
4158

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
All
All
All
All

1802
2450
2200
4770
4887

2002
2450
2200
5750
5360

2202
2450
2200
5750
5431

2352
2450
2200
5750
5968

2502
2450
2200
5750
5944

2652
2450
2200
5750
5975

2802
2450
2200
5750
5989

3002
2450
2200
7160
7169

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
All
All
All
All

3202
2450
2200
7160
7566

3402
2450
2200
8150
8308

3602
2450
2200
9140
8738

3902
2450
2200
10120
10117

4202
2450
2200
10120
10388

4502
2450
2200
11100
10611

4802
2450
2200
11100
10818

5002
2450
2200
11100
12104

Mod. NS
Height
Width
Depth
Weight when empty

(mm)
(mm)
(mm)
(kg)

A
B
C

Vers
All
All
All
All

5202
2450
2200
11100
12710

5402
2450
2200
11100
12783

5702
2450
2200
11100
12856

6003
2450
2200
14490
14467

6303
2450
2200
15470
15846

6603
2450
2200
15470
16117

6903
2450
2200
16450
16298

7203
2450
2200
16450
16505

Cod.: SNSGCHWTUY.01 / 1308

For transport reasons Versions BA and BE, sizes 6003 to 7203, are shipped separated; one module consisting of two compressors and standard
electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the compressor side beneath
the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or
installation manual.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

331

NSI

Air cooled chillers


INVERTER screw compressors, axial fans
Cooling capacity from 257 to 1193 kW

1251/5403
free-cooling

R134a
HIGH

SEASONAL
EFFICIENCY

New generation INVERTER


screw compressor

Features

Available in 14 sizes
Freecooling version
Refrigerant R134a
New generation INVERTER screw compressor:
Continuous capacity control from 15 to 100%
With automatic control of compression ratio
With opto-electronic control of oil level
AC Inverter:
Refrigerant cooled
With control of operating field
With integrated data logger

Three-way valve installed on the hydraulic circuit to modulate flow to the Free-cooling coil
High efficiency version A
Operating limit up to 44 C external air temperature
Compressor acoustical enclosure for low
noise operation
Electronic expansion valve
Dry expansion shell and tube evaporator optimised for refrigerant R134a
Extremely low noise axial fans with options:
- J inverter fans

Pump assembly option (see Unit


Configurator) that includes:
- 1 pump
- 1 pump plus 1 standby
- 2 expansion tanks of 25 litres
Microprocessor controller
Multilingual display
Compact dimensions
Metal control panel with anti-corrosion polyester paint.

AERWEB300: Accessory AERWEB allows


remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
AERWEB300-18G: Web server to monitor and

remote control max. 18 units in RS485 network with integrated GPRS modem;
MULTICHILLER: Control system for multiple
parallel installed constant flow chillers providing individual chiller on/off and control
capability.

Accessories

AER485P1: RS-485 interface for supervision


systems with MODBUS protocol.
AVX: Spring anti-vibration mounts. For compatibility of the AVX mounts refer to the technical manual.
DCPX: Low ambient device for cooling operation below 19 C down to -10 C.
KRS: Evaporator trace heating. Factory fitted
only.
GP: Protective grille. Condenser coil external
protection against accidental or hail damage.
Factory fitted.
PRV3: Remote control of the chiller operating functions.

332

Mod. NSI
AER485P1
AERWEB300
PRV3
MULTICHILLER

1251
(x1)

1401
(x1)

1601
(x1)

1701
(x1)

1801
(x1)

2502
(x2)

2802
(x2)

3202
(x2)

3402
(x2)

3602
(x2)

4203
(x3)

4803
(x3)

5103
(x3)

5403
(x3)

Accessories factory fitted only

GP300M
GP400M
GP500B
GP300M+GP300M
GP400M+GP400M
GP300M+GP300M+GP300M
GP400M+GP400M+GP400M
KRS
1.

(1)

Accessory available for all sizes, to t contact factory

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Configuration fields:
123
|
Code

4567
|
|
|
Size

8
|
Expansion
device

9
10
11
12
|
|
|
|
|
Heat recovery
|
|
|
|
Condenser coil
Model
Version

Code:
NSI
Size:
1251, 1401, 1601, 1701, 1801, 2502, 2802, 3202, 3402, 3602,
4203, 4803, 5103, 5403
Expansion device:
X - R134a electronic expansion valve, minimum leaving water
temperature down to +4 C
(for lower temperatures contact the factory)
Model:
F - Freecooling
Heat recovery:
- Without heat recovery
Version:
A - High efficiency
Condenser coil:
- Aluminium
R - Copper
S - Tinned copper
V - Anti-corrosion coated aluminium

13
|
|
|
Fan

14
|
|
Power supply

15-16
|
|
|
Pump

Fan:
- Standard
J - Inverter
Power supply:
- 400V/3/50Hz with fuses
Pump:
00 - Without pump assembly
PA - Pump assembly (Pump A)
PB - Pump assembly (Pump A and standby pump)
PC - Pump assembly (Pump C)
PD - Pump assembly (Pump C and standby pump)
PE - Pump assembly (Pump E)
PF - Pump assembly (Pump E and standby pump)
PG - Pump assembly (Pump G)
PH - Pump assembly (Pump G and standby pump)
PJ - Pump assembly (Pump J)
PK - Pump assembly (Pump J and standby pump)

333

Technical Data
Vers
Mod. NSI
Cooling capacity
FA
kW
Total input power
FA
kW
Water ow rate
FA
l/h
Pressure drop
FA
kPa
EER
FA
W/W
Cooling capacity (freecooling) FA
kW
Total input power
FA
kW
Water ow rate
FA
l/h
Pressure drop
FA
kPa
EER
FA
W/W
Power supply
V/ph/Hz
Total input current
FA
A
Total input current (freecooling)
FA
A
Maximum current (FLA)
FA
A
Starting current (LRA)
FA
A
Capacity control
FA
%
type
Compressors
FA
n
Refrigerant
FA
type
Refrigerant circuits
FA
n
Air ow rate
FA
m3/h
FA
type
Fans
FA
n
type
Evaporator
FA
n
Sound power
FA
dB(A)
Maximum external air temp.
C

Mod. NSI
Vers
Cooling capacity
FA
kW
Total input power
FA
kW
Water ow rate
FA
l/h
Pressure drop
FA
kPa
EER
FA
W/W
Cooling capacity (freecooling) FA
kW
Total input power
FA
kW
Water ow rate
FA
l/h
Pressure drop
FA
kPa
EER
FA
W/W
Power supply
V/ph/Hz
Total input current
FA
A
Total input current (freecooling)
FA
A
Maximum current (FLA)
FA
A
Starting current (LRA)
FA
A
Capacity control
FA
%
type
Compressors
FA
n
Refrigerant
FA
type
Refrigerant circuits
FA
n
Air ow rate
FA
m3/h
FA
type
Fans
FA
n
type
Evaporator
FA
n
Sound power
FA
dB(A)
Maximum external air temp.
C

1251
257
92
44430
49
2,79
277
10,5
44430
81
26,38

1401
295
104
50980
64
2,83
282
10,5
50980
105
26,88

146
19
183
21
24-100

165
19
214
21
20-100

1
107000

1
102000

1
99
44

1
101
44

3202
639
238
110320
46
2,68
572
21,0
110320
94
27

3402
736
266
127240
66
2,77
730
28,0
127240
140
26

379
38
489
127
9-100

421
51
558
134
9-100

2
204000

2
272000

12

16

2
106
44

2
105
44

1601
319
119
55160
46
2,68
286
10,5
55160
94
27,24

1701
1801
368
397
133
149
63620
68690
66
66
2,77
2,67
365
394
14,0
14,0
63620
68690
140
152
26,07
28,14
430/3/50Hz
190
211
236
19
25
25
245
279
313
21
24
24
18-100
17-100
15-100
screw - inverter
1
1
1
R134a
1
1
1
102000
136000
136000
Axial
6
8
8
shell and tube evaporator
1
1
1
103
102
102
44
44
44

3602
795
297
137390
66
2,67
788
28,0
137390
152
28

4203
4803
885
959
312
357
152950
165470
64
46
2,83
2,68
847
858
31,5
31,5
152950
165470
105
94
27
27
430/3/50Hz
471
495
569
51
57
57
626
641
734
134
234
234
9-100
7-100
7-100
screw - inverter
2
3
3
R134a
2
3
3
272000
306000
306000
Axial
16
18
18
shell and tube evaporator
2
3
3
105
106
107
44
44
44

Data declared in accordance with UNI EN 14511:2013


Sound power:
COOLING MODE
Aermec determines sound power values on the basis
Entering water temperature
12 C
of measurements made in accordance with UNI EN
Leaving water temperature
7 C
ISO 9614-2, as required for Eurovent certification.
External air temperature
35 C
Sound pressure:
FREECOOLING MODE
Sound pressure in free field, at 10 m distance from
Entering water temperature
15 C
the external surface of the unit (in accordance with
External air temperature
2 C
UNI EN ISO 3744)
Glycol
0%

334

2502
516
182
89480
106
2,83
505
17,5
89480
206
28,86

2802
566
214
98180
126
2,64
510
17,5
98180
246
29,14

287
32
362
124
12-100

336
32
416
124
12-100

2
170000

2
170000

10

10

1
102
44

1
104
44

5103
1105
398
190860
66
2,77
1095
42,0
190860
140
26

5403
1193
457
206080
66
2,61
1182
42,0
206080
152
28

632
76
837
244
7-100

726
76
939
244
7-100

3
408000

3
408000

24

24

3
107
44

3
107
44

Dimensions (mm)

C
B

A
B
C

mm
mm
mm
kg

1251
2450
2200
3780
3296

1401
2450
2200
3780
3399

1601
2450
2200
3780
3569

1701
2450
2200
4770
4216

1801
2450
2200
4770
4400

2502
2450
2200
5750
5955

2802
2450
2200
5750
6128

3202
2450
2200
7160
7127

3402
2450
2200
9140
8349

3602
2450
2200
9140
8594

4203
2450
2200
10940
10154

4803
2450
2200
10940
10664

5103
2450
2200
13510
12493

5403
2450
2200
13510
13046

Cod.: SNSIFCUY.01/ 1411

Mod. NSI
Height
Width
Lenght
Weight empty

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

335

Venice

Water-cooled reversible heat pumps units


With capacities from 6,9 up to 9,7 kW

R407C

Aermec
participates in the EUROVENT
Program LCP
The products of interest can be
found on the website
www.eurovent-certification.com

Features
Available in 3 sizes
Versions:
Venice: cooling only
Venice H: heat pump
Cycle reversal on refrigerant circuit
All versions are equipped with circulation
pump, water tank, water filter and safety
valve

Complies with EEC Safety Directive (CE)


Compact size
High efficiency scroll compressors
Metallic protective cabinet with rustproof
Differential pressure switch on the external
polyester paint
circuit standard on heat pumps
Degree of protection IP 24
Fluxostat standard on installation circuit
Modular microprocessor control system
Straightforward intuitive control panel
High efficiency plate type heat exchangers

Accessories
PR3: Remote control panel with ON/OFF,
ser, thereby maintaining the condensation
the water flows through both branches of the
operating mode selection (cooling / heating)
temperature unchanged.
circuit.
and general alarm indication.
VPH: Pressure switch valve with bypass sole- VT: Rubber anti-vibration mounts.
VP: Pressure switch valve complete with connoid valve: during cooling mode operation VT M: Spring anti-vibration mounts.
nections, piloted directly in relation to conthe bypass valve is closed so the water flows
densation pressure; the valve modulates the
exclusively through the circuit with the presvolume of water needed to cool the condensure switch. During heating mode operation

Compatibility of accessories
Mod. Venice
20
20 H
25
25 H
30
30 H

336

PR 3

VP 14

VP 15

VPH 10

VPH 11

VT 7

VT M

Technical data
Mod. Venice
Cooling capacity
Total input power*
Evaporator water flow rate
Usefoul head system side circuit
Condenser water consumption
Condenser pressure drop
Heating capacity
Total input power*
Condenser water flow rate
Usefoul head system side circuit
Condenser water consumption (10 C)
Evaporator pressure drop
ENERGY INDEX
EER
ESEER
COP
ELETTRICAL DATA
Power supply
Input current
Input current
Max. current (FLA)
Peak current (LRA)
SOUNDA DATA
Sound power
Sound pressure
HYDRAULIC CONNECTION
Hydraulic connection**
Storage tank capacity
Compressor

kW
kW
l/h
kPa
l/h
kPa
kW
kW
l/h
kPa
l/h
kPa

20
6,92
1,95
1187
63
1485
18
-

20H
6,92
1,92
1187
63
1485
9
7,77
2,59
1342
61
929
2

25
8,23
2,22
1410
61
1758
13
-

25H
8,23
2,22
1410
61
1758
10
9,26
3,08
1600
59
1106
2

30
9,74
2,62
1668
59
2080
12
-

30 H
9,74
2,62
1668
59
2080
11
10,85
3,57
1875
57
1300
2

W/W
W/W
W/W

3,56
4,59
-

3,60
4,00
3,00

3,70
4,58
-

3,71
4,23
3,00

3,72
4,58
-

3,72
4,24
3,04

A
A
A
A

10,18
15
61

10,18
13,39
15
61

230V ~ 50Hz.
11,89
11,89
15,70
18
18
76
76

13,18
24
100

13,81
18,31
24
100

dB(A)
dB(A)

56,5
48,0

56,5
48,0

56,5
48,5

57,0
48,5

57,5
49,0

57,5
49,0

l
type

1
23
Scroll

1
23
Scroll

1
23
Scroll

1
23
Scroll

1
23
Scroll

1
23
Scroll

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2013

*
**

Cooling
processed water temperature 7 C;
water inlet temperature to condenser 30 C;
't = 5 C.
Heating
processed water temperature 50 C;
water inlet temperature to evaporator 10 C;
't = 5 C.

Sound power
Aermec determines sound power values on the
basis of measurements made in accordance
with UNI EN ISO 9614-2, as required for
Eurovent certification.

Power supply = 1~ 230V 50Hz.

Sound pressure
Sound pressure in free field, at 10 m distance
from the external surface of the unit (in
accordance with UNI EN ISO 3744)

including circulator pump power consumption.


male Gas connection.

Mod. Venice
20
25 - 30

mm
mm

A
504
504

B
404
404

C
625
625

D
190
190

E
83
83

F
20
20

G
48
48

H
465,5
465,5

I
20
20

L
25
25

Mod. Venice
20
25 - 30

mm
mm

M
130
130

N
40
40

O
20
20

P
118
118

Q
77
77

R
304
304

S
249
249

T
120
120

U
220
220

V
111
111

Mod. Venice
Peso [Kg]

Venice
Venice H

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

20
100
103
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

25
103
106

30
105
109

337

Cod.: SVNCUY.05 / 1502

Dimensions (mm)

WRL

Water/Water chillers for indoor installation


Scroll compressors, plate heat exchangers
Cooling capacity 6,643,4kW

026/161
cooling only
DISPLAY
MODU_CONTROL

R410A

KSAE
External air sensor
ACCESSORY
Aermec participate in the
EUROVENT program: LCP,
the products are present on the site
www.eurovent-certification.com

HIGH EFFICIENCY
POSSIBILITY OF HAVING:
DESUPERHEATER
IDEAL FOR GEOTHERMAL APPLICATIONS

PR3
Simplified remote panel
ACCESSORY

Characteristics
WRL is the range of water-cooled chillers operating with R410A refrigerant. These indoor units
feature hermetic scroll compressors, system side
heat exchangers and source with plates, which
fully meet the needs of the residential market:
small size, easy installation, low noise.
In the units with desuperheater there is also the
possibility of producing hot water for free.
The base, the structure and the panels are made
of steel treated with rustproof polyester paint.
The technological choices made, always oriented to the highest quality, ensure very easy
installation.
In fact the electrical and hydraulic connections
are all located in the upper part of the unit, facilitating the installation and maintenance opera-

tions and also reducing the technical gaps and


their position in as little space as possible.

inverter pumps and the possibility of a modulating valve for reducing consumption (source
side, for groundwater applications)
Versions
Microprocessor adjustment, with keyboard
WRL_ standard without storage tank
and LCD display, for easy intervention on the
WRL_A with system storage tank
unit via a menu available in several languages.
Single-circuit unit
Adjusting the unit with an external air tempe Water filter, differential pressure switch and
rature probe (accessory) ensures dynamic
water safety valve as standard on the system
temperature control of the water produced,
and source sides and also on the domestic
increasing the energetic efficiency of the
hot water side if envisaged.
system.
Possibility of a hydronic kit (on the source
and system side), which encloses the main
hydraulic components; available in different
configurations, with low or high head pumps,

Accessories
MODU-485A: RS-485 interface for supervising systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
- AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
- AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
- AERWEB300-6G: Web server to monitor and

338

remote control max. 6 units in RS485 network with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network with integrated GPRS modem;
AERSET: The AERSET accessory allows the
automatic compensation of the operating
setpoint of the unit to which it is connected,
based on a 0-10V MODBUS input signal.
Mandatory accessory: AER485 or MODU485A
PR3: Simplified remote panel. Allows control
of the basic unit functions and alarm notifi-

cation. Remote mounted up to 150 m distance with a shielded cable.


KSAE: External air sensor. Temperature sensor
with plastic enclosure.
VT: Anti-vibration mounts: four anti-vibration
mounts to be installed under the unit's steel
base.

Accessory compatibility
WRL
MODU-485A
AERWEB300
AERSET
PR3
KSAE
VT (version )
VT (version A)

026

9
15

031

9
15

041

9
15

051

9
15

071

9
15

081

9
15

101

15
15A

141

15
15A

161

15
15A

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of
system requirements.
Field
1,2,3
4,5,6
7

Y
8

E
9

A
10

D
11

B
U
I
V
12

P
N
13

Description
WRL
Size
026-031-041-051-071-081-101-141-161
Field of use
Standard (with leaving water down to +4 C)
Low temperature (with leaving water up +4C to -8C)
Model
Cooling only
Evaporating unit (shipped with holding charge only)
Version
Without buffer tank
With buffer tank
Heat recovery
Without recovery
Desupeheater
Geothermal side kit pumps version
Without pump
Geothermal applications
Circulator On/Off (WRL026081)
Pumps On/Off (WRL101161)
High head pump (WRL101161)
Inverter pump (WRL026081)
Applications with bore hole water
2-way modulating valve
System side kit pumps version
Without pump
Circulator On/Off (WRL026081)
Pumps On/Off (WRL101161)
High head pump (WRL101161)
Filed not used

14

15

Soft-start
Without soft-start
S With soft-start
Power supply
400/3N/50Hz
M 230V/1/50Hz (WRL026041)

339

Technical Data
Mod. WRL_
Cooling capacity
Input power
EER
ESEER
Water flow rate system side
Pressure drops system side
Water flow rate geothermal side
Pressure drops geothermal side

kW
kW
W/W
W/W
l/h
kPa
l/h
kPa

Mod. WRL_A (1)


Cooling capacity
Input power
EER
Water flow rate system side
Useful head system side
Water flow rate geothermal side
Useful head geothermal side
Power supply

kW
kW
W/W
l/h
kPa
l/h
kPa
V/ph/Hz

Mod. WRL_
Cooling capacity
Input power
EER
ESEER
Water flow rate system side
Pressure drops system side
Water flow rate geothermal side
Pressure drops geothermal side

kW
kW
W/W
W/W
l/h
kPa
l/h
kPa

Mod. WRL_A (1)


Cooling capacity
Input power
EER
Water flow rate system side
Useful head system side
Water flow rate geothermal side
Useful head geothermal side
Power supply

kW
kW
W/W
l/h
kPa
l/h
kPa
V/ph/Hz

026
6.58
1.56
4.20
4.22
1138
15
1391
28
026A
6.64
1.60
4.15
1138
66
1391
51

031
8.27
1.89
4.37
4.41
1432
17
1739
29

041
11.26
2.66
4.24
4.34
1951
23
2380
36

051
-

071
-

081
-

101
-

141
-

161
-

031A
041A
8.36
11.39
1.90
2.60
4.30
4.18
1432
1951
63
53
1739
2380
47
36
230V/1/50Hz

051A
-

071A
-

081A
-

101A
-

141A
-

161A
-

026
6.68
1.53
4.37
4.42
1138
15
1383
28

031
8.37
1.81
4.61
4.65
1449
17
1741
30

041
11.26
2.57
4.39
4.46
1934
23
2348
35

051
14.66
3.22
4.55
4.59
2520
21
3044
32

071
19.16
4.15
4.62
4.58
3299
26
3973
40

081
21.76
4.85
4.49
4.46
3752
30
4539
46

101
29.36
6.38
4.60
4.89
5061
25
6109
42

141
38.38
8.25
4.65
4.84
6591
34
7940
57

161
43.69
9.63
4.54
4.69
7514
38
9090
66

026A
6.64
1.55
4.27
1138
66
1383
52

031A
8.46
1.81
4.69
1449
63
1741
48

041A
11.29
2.52
4.49
1933
53
2348
38

051A
14.73
3.18
4.63
2520
82
3044
68

071A
19.27
4.06
4.74
3299
72
3973
53
400V/3N/50Hz

081A
21.90
4.75
4.61
3751
65
4539
43

101A
29.95
6.40
4.68
5061
147
6110
116

141A
39.00
8.32
4.68
6591
164
7940
137

161A
44.41
9.71
4.57
7514
158
9090
125

081E
-

101E
-

141E
-

161E
-

17.4
19.7
4.5
5.3
3.83
3.71
2980
3390
21
24
400V/3N/50Hz

26.8
7.2
3.73
4600
21

34.7
9.1
3.83
5970
28

39.4
10.6
3.71
6770
31

(1) Data relating to the version with storage tank and pump "B" on geothermal side, pump "P" on utility side
Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C;
Condenser water temperature (in/out) 30C/35C

Mod. WRL_E
Cooling capacity
Input power
EER
Water flow rate system side
Pressure drops system side
Power supply

kW
kW
W/W
l/h
kPa
V/ph/Hz

Potenza frigorifera
Potenza assorbita
EER
Water flow rate system side
Pressure drops system side
Power supply

kW
kW
W/W
l/h
kPa
V/ph/Hz

026E
6.2
1.7
3.56
1070
13

031E
7.8
2.1
3.65
1340
15
230V/1/50Hz

041E
10.4
2.9
3.63
1790
20

051E
-

6.3
1.7
3.7
1080
13

7.8
2.0
3.87
1340
15

10.4
2.8
3.75
1790
20

13.4
3.6
3.73
2300
18

Cooling
Evaporator water temperature (in/out) 12C/7C; Condensing temperature 45C

340

071E
-

Technical Data
026

031

041

051

071

081

101

141

161

A
A
A
A
A
A
A
A

7.2
8.3
4.2
3.4
18
8
63
34

9.2
10.5
4.5
3.2
21
8
84
37

11.7
12.8
4.9
5.4
34
15
119
65

6.4
7.2
17
75

7.4
8.3
21
75

9.1
10.2
22
75

12.8
14.3
32
90

14.8
16.6
40
94

18.2
20.5
41
95

type
n
n
type

1
1

1
1

1
1

1
1

scroll
1
1
R410A

1
1

2
1

2
1

2
1

(in/out)

type
n

1
F 1"

1
F 1"

1
F 1"

1
F 1"

plate
1
F 1"

1
F 1"

1
F 1"

1
F 1"

1
F 1"

(in/out)

type
n

1
F 1"

1
F 1"

1
F 1"

1
F 1"

plate
1
F 1"

1
F 1"

1
F 1"

1
F 1"

1
F 1"

l
n/l
n/l

100
1/2
1/8

100
1/2
1/8

100
100
100
100
150
1/2
1/2
1/2
1/2
1/8
1/8
1/8
1/8
1/8
1/8
for more information, refer to the selection program

150
1/8
1/8

150
1/8
1/8

dB(A)
dB(A)

55.5
24.3

57.0
25.8

57.5
26.3

63.0
31.6

63.5
32.1

Electrica data
230V

Total input current

400V

Total input current

(2)
(2)
(2)
(2)

230V
400V
230V
400V

Max. current (FLA)


Peck current (LRA)
Compressor
Compressors
Circuit
Refrigerant
Heat exchanger system side
Evaporators
Connections
Heat exchanger geothermal side
Condenser
Connections
Hydronic kit

Buffer tank
Expansion tank (with pump)
Expansion tank (with pump and buffer tank)
Useful head
Sound data
Sound power
Sound pressure

59.0
27.7

60.0
28.7

60.5
29.2

62.0
30.6

(2) The data of the versions without hydronic module integrated


Sound power (cooling mode)
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure (cooling mode)
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)

A
A

A
A

C
C

WRL -E
Height (A)
Width (B)
Depth (C)
Weight WRL
Weight WRLE
WRL-A
Height (A)
Width (B)
Depth (C)
Weight *

WRL 051-081

mm
mm
mm
kg
kg

mm
mm
mm
Kg

WRL 101-161

026
976
605
603
120
110

031
976
605
603
125
115

041
976
605
603
130
125

026
1126
1155
773
190

031
1126
1155
773
200

041
1126
1155
773
210

WRL-A 101-161

WRL-A 026-081
051
1126
605
773
150
150
051
1126
1155
773
230

071
1126
605
773
170
150
071
1126
1155
773
250

081
1126
605
773
180
150
081
1126
1155
773
260

101
1126
1155
773
260
245
101
1126
1755
773
340

141
1126
1155
773
270
250
141
1126
1755
773
350

161
1126
1155
773
280
250
161
1126
1755
773
360

* Weight with two heat exchangers and buffer tank without pumps.
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

341

Cod.: SWRLUY.02 / 1502

WRL 026-041

WRL
180/650

reversible
water-side

Chillers reversible
Water/Water for indoor installation
with scroll compressor plate exchanger
Cooling capacity 50173kW
Heating capacity 51184kW

R410A
Aermec participates in the EUROVENT
Programme: LCP
The products of interest can be found
on the website
www.eurovent-certification.com

PGD1
Simplified remote panel.
ACCESSORY

TAT - TAH
terminal environment
ACCESSORY

HIGH EFFICIENCIES
POSSIBILITY OF HAVING:
PARTIAL HEAT RECOVERY
PRODUCTION OF HOT WATER UP TO 55 C
SUITABLE FOR GEOTHERMAL APPLICATIONS
Characteristics
WRL is the range of water cooled chillers
operating with refrigerant R410A. They are internal units with hermetic scroll compressors that
respond perfectly to the market
requirements: small dimensions, ease of installation, low noise.

Dynamic set point


electrical input
Using the latest generation of electronic control- Flow switch as standard
ler and with an external air temperature sensor Conforms with Safety Directives (CE) and the
(accessory), the heat pump unit can vary the
standards regarding electromagnetic
leaving water temperature based on climatic
compatibility
conditions, thus increasing the energy efficiency
The safety of the unit is provided by the door
of the system.
interlocked isolator and active protection of
High efficiency
the main components
Aermec has designed these units to optimise Advantages
Externally mounted user interface with disheat pump operation, providing high perfor- Using the latest innovative technology and focus
play of all operating parameters in 4 lanmances and low energy consumption.
on maximum quality gives the WRL series the
guages
maximum energy efficiency, ease of installation, Latest generation of electronic controller
Connections
and most versatile application using renewable User-friendly remote mounted control panel
The electric and hydraulic connections are all energy sources.
with alarm notification.
located on the upper part of the unit
facilitating installation and maintenance. This Model
allows reduced plant room space and installa- WRL_: Reversible water-side
tion in the smallest space possible.
WRL_K: Reversible water-side with low pres
sure drops system side
Silent
WRL_E: Evaporating unit
The WRL units are distinguished for their silence
in operation. Careful soundproofing of the unit Technical features
with suitable sound-absorbent material results Structure and base in hot dip galvanised sheet
in low sound levels for all units.
steel with epoxy paint finish (RAL 9002)
Generously sized plate heat exchangers
Compressors with high performance and low

342

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows remote
control of a chiller through a common PC and an
ethernet connection over a common browser; 4
versions available:
- AERWEB300-6: Web server to monitor and remote
control max. 6 units in RS485 network;
- AERWEB300-18: Web server to monitor and remote
control max. 18 units in RS485 network;
- AERWEB300-6G: Web server to monitor and remote
control max. 6 units in RS485 network with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network
with integrated GPRS modem;
VT: Anti-vibration mounts: four anti-vibration

mounts to be installed under the unit's steel base.


TAT: Room temperature sensor, 230 Vac recess
mounted kit containing the ambient sensor with
display and control knob, able to control an
ON-OFF valve or a zone pump.
TAH: Room temperature and humidity sensor, 230
Vac recess mounted kit containing the sensor
with display and control knob, able to control an
ON-OFF valve or a zone pump and dehumidifier
enable.
SSM: Sensor to be used together with the mixing
valve in applications with radiant panels.
Accessory to be requested together with the
VMFCRP zone accessory.
S...I: System buffer tanks: available in sizes 200,
300, 400 and 500 litres (S200I, S300I, S400I and
S500I).

PGD1: Simplified remote panel. Allows control of


basic unit functions and alarm notification.
Remote mounted up to 500 m away with TWISTED
PAIR SCREENED cable and TCONN6J000.
KSAE: External air sensor. Temperature sensor with
plastic enclosure.
VMFCRP: WRL Zones Control can control up to a
maximum of 3 zones with the following modes:
- Zone 1: Controlled as standard with the latest
generation electronic controller. The "SSM"
clamp on sensor (accessory) is recommended to
control the flow temperature.
- The control of the remaining Zone 2 and Zone 3
is possible using the VMFCRP + SSM accessories
for each zone.

Accessory compatibility
WRL

180

200

300

400

500

550

600

650

AERWEB300

VT

15

15

15

15

TAT

AER485P1

TAH
SSM
S...I (200-300-400-500)
PGD1
KSAE
VMFCRP

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of
system requirements.
Field
1,2,3
4,5,6
7

Y
X
8

K
E
9

10

D
11

B
U
F
I
V

P
N
12

Code
WRL
Size
180-200-300-400-500-550-600-650
Filed use
Standard (Standard with leaving water above +4C)
Low temperature with leaving liquid down to -8C
Electronic expansion valve with leaving liquid down to +4C (for different temperature contact us)
Model
Reversible water-side
Reversible water-side with low pressure drops system side
Evaporating unit (1)
Version
Standard
Heat recovery
Without heat recovery
Con desurriscaldatore
Pumps condenser side
Without pumps
Low static pressure pump
High static pressure pump
Low static pressure inverter pump
High static pressure inverter pump
2-way modulating valve
Pumps evaporator side
Without pumps
Low static pressure pump
High static pressure pump
Field not used

13

13

Soft-start
Without Soft Start
S With Soft Start
Power supply
400V/3/50Hz
5 500V/3/50Hz (2)

(1) shipped with holding charge only


(2) 500V/3/50Hz only size 400650

343

Technical data
Model WRL_ standard
Cooling capacity
Imput power
E.E.R.
E.S.E.E.R.
Evaporator water flow rate
Pressure drops system side
Condenser water flow rate
Pressure drops geothermal side
Heating capacity
Imput power
COP
Condenser water flow rate
Pressure drops system side
Evaporator water flow rate
Pressure drops geothermal side

(3)
(3)
(3)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

180
50
10,95
4,52
4,61
8559
27
10176
27
51
12,79
4,02
8808
20
6668
19

200
64
14,52
4,42
4,43
11094
43
13210
46
69
17,46
3,97
11858
37
8963
31

300
74
16,91
4,39
4,40
12838
46
15290
62
76
19,16
3,98
13031
44
9859
30

400
86
18,34
4,67
4,40
14838
60
17459
81
89
21,29
4,18
15201
61
11711
41

500
100
20,51
4,86
5,47
17205
30
20242
32
102
23,49
4,35
17494
24
13560
20

550
129
26,96
4,79
5,67
22320
49
26265
52
140
32,51
4,32
24030
44
18640
37

600
150
30,98
4,83
5,23
25872
53
30400
57
161
37,00
4,34
27518
47
21381
38

650
168
35,73
4,71
4,82
29126
67
34312
72
180
42,04
4,28
30791
59
23843
47

400K
88
18,31
4,83
4,40
15284
48
17904
85
91
21,30
4,28
15563
64
12422
35

500K
100
20,51
4,86
5,47
17205
30
20242
32
102
23,49
4,35
17494
24
13560
20

550K
133
26,75
4,98
5,67
22990
24
26934
55
144
32,38
4,44
24605
46
19754
20

600K
154
30,81
5,01
5,23
26648
33
31176
60
164
37,00
4,46
28178
49
22655
25

650K
173
35,55
4,89
4,82
30000
41
35186
76
184
41,96
4,39
31528
62
25274
32

400E
80,1
19,8
4,1
13770
56

500E
90,6
23,1
3,9
15580
25

550E
121,3
29,6
4,1
20860
42

600E
140,2
34,1
4,1
24110
47

650E
158,7
38,5
4,1
27300
57

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; Condenser water temperature (in/out) 30C/35C
(3) EUROVENT for reversible units side water certi es the sun made cold (12/7C - 30/35C)
Heating
Condenser water temperature (in/out) 40C/45C; Evaporator water temperature (in/out) 10C/5C

Model WRL_K low pressure drops


Cooling capacity
Imput power
E.E.R.
E.S.E.E.R.
Evaporator water flow rate
Pressure drops system side
Condenser water flow rate
Pressure drops geothermal side
Heating capacity
Imput power
COP
Condenser water flow rate
Pressure drops system side
Evaporator water flow rate
Pressure drops geothermal side

(3)
(3)
(3)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

180K
50
10,95
4,52
4,61
8559
27
10176
27
51
12,79
4,02
8808
20
6668
19

200K
66
14,49
4,56
4,43
11427
34
13543
48
71
17,46
4,06
12135
39
9530
25

300K
76
16,91
4,52
4,40
13223
42
15675
65
78
19,19
4,06
13336
46
10482
30

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; Condenser water temperature (in/out) 30C/35C
(3) EUROVENT for reversible units side water certi es the sun made cold (12/7C - 30/35C)
Heating
Condenser water temperature (in/out) 40C/45C; Evaporator water temperature (in/out) 10C/5C

Model WRL_E evaporating unit


Cooling capacity
Imput power
E.E.R.
Evaporator water flow rate
Pressure drops system side

kW
kW
W/W
l/h
kPa

180E
46,0
12,4
3,7
7900
23

200E
60,1
16,0
3,8
10340
39

Cooling
Evaporator water temperature (in/out) 12C/7C; Condensing temperature 45C

344

300E
69,6
18,5
3,8
11980
39

Technical data
GENERAL DATA
Electrical data
Total input current cooling mode
Total input current heating mode
Total input current cooling mode
Maximum current (FLA)
Starting current (LRA)
Compressors

(4)
(4)
(4)

A
A
A
A
A

180

200

300

400

500

550

600

650

19,90
22,80
22,9
32
119

25,00
29,50
28,5
42
123

28,50
32,00
32,4
45
125

31,90
35,90
35,6
52
167

36,30
41,10
41,8
59
174

50,80
57,80
55,8
99
265

59,30
66,70
64,8
112
310

68,30
76,10
73,9
125
323

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

1
2"

1
2"

1
2"

1
2"

1
2"

1
2"

1
2"

1
2"

1
1"

1
1"

47,1
79,1

47,1
79,1

type
n
n
%
type

Compressors
Circuits
Capacity control
Refrigerant
System side exchanger
Evaporator
Hydraulic connections Victaulic (in/out)
Geothermal side exchanger
Condenser
Hydraulic connections Victaulic (in/out)
Heat recovery side exchanger
Desuperheater
Hydraulic connections Victaulic (in/out)
Hydronic kit
Sound data
Sound pressure
Sound power
Power supply

Scroll

50-100
R410A

type
n

1
2"

1
2"

1
2"

1
2"

Plate

type
n

1
2"

1
2"

1
2"

1
2"

type
n

1
1"

1
1"

29,1
61,1

29,8
61,8

Plate

dB(A)
dB(A)
V/ph/Hz

Plate
1
1
1
1
1"
1"
1"
1"
for more information, refer to the selection program
30,9
62,9

39,1
35,6
71,1
67,6
400V/3/50Hz

47,1
79,1

(4) The electrical data of the versions without hydronic module integrated
Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

Dimensions (mm)

B
C

WRL 180-400

Model WRL
Height
Width
Depth
Weight

A
B
C

mm
mm
mm
kg

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

180
1380
1320
845
375

200
1380
1320
845
375

300
1380
1320
845
381

400
1380
1320
845
388

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

500
1380
2060
845
518

550
1380
2060
845
594

600
1380
2060
845
670

650
1380
2060
845
715

345

Cod.: SWRL2UY.05 / 1503

WRL 500-650

WRL

026/161
heat

Reversible heat pumps Water/Water for indoor installation


Scroll compressors, plate heat exchangers
Cooling capacity 6,340,3kW
Heating capacity 7,948,1kW

pumps
WRL

R410A

Aermec participate in the EUROVENT


program: LCP,
the products are present on the site
www.eurovent-certification.com

TAT - TAH
ACCESSORIES

PGD1

Simplified remote panel.


ACCESSORIES

HIGH EFFICIENCY
PRODUCTION OF HOT WATER UP TO 60 C PRIORITY
PRODUCTION OF DOMESTIC HOT WATER
IDEAL FOR GEOTHERMAL APPLICATIONS
Characteristics
The WRL water-cooled heat pumps are reversible
products for the production of chilled, hot and domestic hot water. These indoor units feature hermetic
scroll compressors, system side heat exchangers and
source with plates, which fully meet the needs of the
residential market: small size, easy installation, low
noise. They can be installed in traditional systems or
with radiant panels.
In the latter, by using lower water temperatures, they
ensure better overall efficiency. They are particularly
suitable for new low consumption buildings that
mainly use renewable energy sources.
In the total recovery systems there is also the possibility to produce domestic hot water with priority both
in summer and in winter. The unit is supplied with a
temperature probe for a possible DHW storage tank.
The base, the structure and the panels are made of
steel treated with rustproof polyester paint.

The technological choices made, always oriented to


the highest quality, ensure very easy installation.
In fact the electrical and hydraulic connections are
all located in the upper part of the unit, facilitating
the installation and maintenance operations and also
reducing the technical gaps and their position in as
little space as possible.
Versions
WRL_H Heat pump without storage tank
WRL_HA with system storage tank
Operational limits: Operation at full power with
domestic hot water for the system up to 60C. For
further details refer to the technical/selection software documentation.
Single-circuit unit
Water filter, differential pressure switch and water

safety valve as standard on the system and source


sides and on the domestic hot water side if envisaged.
Possibility of a hydronic kit, which encloses the
main hydraulic components; available in different
configurations, with high or low static pressure
pumps, inverter pumps and the possibility of a
modulating valve for reducing consumption
(source side, for groundwater applications)
Microprocessor adjustment, with keyboard and
LCD display, for easy intervention on the unit via a
menu available in several languages.
Adjusting the unit with an external air temperature
probe (accessory) ensures dynamic temperature
control of the water produced, increasing the
energetic efficiency of the system.

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
- AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
- AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
- AERWEB300-6G: Web server to monitor and

346

control an ON-OFF valve or a zone pump


remote control max. 6 units in RS485 netand dehumidifier enable.
work with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and SSM: Sensor to be used together with the
mixing valve in applications with radiant panremote control max. 18 units in RS485 netels. Accessory to be requested together with
work with integrated GPRS modem;
the VMFCRP zone accessory.
VT: Anti-vibration mounts.
TAT: Room temperature sensor. 230 Vac recess S...I: System buffer tanks: available in sizes
mounted kit containing the ambient sensor
200, 300, 400 and 500 litres (S200I, S300I,
with display and control knob, able to control
S400I and S500I).
an ON-OFF valve or a zone pump.
PGD1: Simplified remote panel. Allows control
of basic unit functions and alarm notification.
TAH: Room temperature and humidity sensor.
230 Vac recess mounted kit containing the
Remote mounted up to 500 m away with
sensor with display and control knob, able to
TWISTED PAIR SCREENED cable and

TCONN6J000.
KSAE: External air sensor. Temperature sensor
with plastic enclosure.
VMFCRP: WRL Zones Control can control
up to a maximum of 3 zones with the following modes:

- Zone 1: Controlled as standard with the


latest generation electronic controller. The
"SSM" clamp on sensor (accessory) is recommended to control the flow temperature.
- The unit is shipped with a temperature sensor kit for the DHW tank.

- The control of the remaining Zone 2 and


Zone 3 is possible using the VMFCRP + SSM
accessories for each zone.

Accessory compatibility
WRL_H
AER485P1
AERWEB300
VT (vers. H)
VT (vers. HA)
TAT
TAH
SSM
S...I (200-300-400-500)
PGD1
KSAE
VMFCRP

026H

9
15

031H

9
15

041H

9
15

051H

9
15

071H

9
15

081H

9
15

101H

15
15A

141H

15
15A

161H

15
15A

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of
system requirements.
Field
1,2,3
4,5,6
7
X
8
H
9

A
10

T
11

B
U
I
V
12

P
N
13

Q
14

S
15

M
4

Description
WRL
Size
026-031-041-051-071-081-101-141-161
Field of use
Electronic thermostatic valve (temperature of water produced
up to +4 C) for other temperatures, contact the head office.
Model
Heat pumps
Version
Standard
With buffer tank
Heat recovery
Without recovery
With total recovery
Geothermal side pump kit
Without pump
Geothermal applications
Circulator On/Off (WRL026081)
Pump On/Off (WRL101161)
High head pump (WRL101161)
Inverter pump (WRL026081)
Applications with bore hole water
2-way modulating valve
System side kit pumps version
Without pump
Circulator On/Off (WRL026081)
Pumps On/Off (WRL101161)
High head pump (WRL101161)
Heat recovery side kit pump version
Without pump
Pump
Soft-start
Without soft-start
With soft-start
Power supply
400/3N/50Hz
230V/1/50Hz (WRL026041)
230V/3/50Hz (only for sizes WRL051141)

347

Technical Data
Mod. WRL_H
Cooling capacity
Input power
EER
ESEER
Water flow rate system side
Pressure drops
Water flow rate geothermal side
Pressure drops
Heating capacity
Input power
COP
Water flow rate system side
Pressure drops
Water flow rate geothermal side
Pressure drops

kW
kW
W/W
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

Mod. WRL_HA (1)


Cooling capacity
Input power
EER
Water flow rate system side
Useful head
Water flow rate geothermal side
Useful head
Heating capacity
Input power
COP
Water flow rate system side
Useful head
Water flow rate geothermal side
Useful head
Power supply

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa
V/ph/Hz

Mod. WRL
Cooling capacity
Input power
EER
ESEER
Water flow rate system side
Pressure drops
Water flow rate geothermal side
Pressure drops
Heating capacity
Input power
COP
Water flow rate system side
Useful head
Water flow rate geothermal side
Useful head

kW
kW
W/W
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

Mod. WRL_HA (1)


Cooling capacity
Input power
EER
Water flow rate system side
Useful head
Water flow rate geothermal side
Useful head
Heating capacity
Input power
COP
Water flow rate system side
Useful head
Water flow rate geothermal side
Useful head
Power supply

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa
V/ph/Hz

026H
6.28
1.73
3.63
3.97
1086
9
1371
14
7.93
2.10
3.78
1355
20
1700
34
026HA
6.34
1.79
3.54
1086
67
1371
58
7.85
2.10
3.74
1355
60
1700
38

031H
7.88
1.97
4.00
4.37
1362
10
1686
16
10.01
2.62
3.82
1709
22
2150
36

041H
10.27
2.50
4.11
4.42
1776
13
2186
19
12.68
3.39
3.74
2164
29
2720
46

031HA
041HA
7.95
10.36
1.99
2.49
3.99
4.16
1362
1776
65
54
1686
2186
50
45
9.94
12.54
2.53
3.23
3.93
3.88
1709
2164
56
46
2174
2720
30
25
230V/1/50Hz

051H
-

071H
-

081H
-

101H
-

141H
-

161H
-

051HA
-

071HA
-

081HA
-

101HA
-

141HA
-

161HA
-

071H
17.66
4.39
4.03
4.23
3055
16
3770
24
20.95
5.32
3.94
3591
32
4569
50

081H
20.16
5.14
3.92
4.10
3489
18
4326
27
24.19
6.23
3.88
4130
38
5232
59

101H
27.46
6.30
4.36
5.28
4741
20
5771
28
32.93
8.22
4.01
5628
35
7178
52

141H
35.26
8.75
4.03
4.84
6100
24
7525
37
41.90
10.55
3.97
7157
43
9110
62

161H
40.27
10.26
3.92
4.56
6968
29
8636
44
47.94
12.40
3.86
8224
51
10403
73

101HA
28.08
6.25
4.49
4741
154
5771
126
32.20
8.09
3.98
5628
129
7178
88

141HA
36.12
8.73
4.14
6100
170
7525
147
40.93
10.37
3.95
7157
153
9110
129

161HA
41.22
10.18
4.05
6968
164
8636
136
47.10
12.16
3.87
8224
143
10403
113

026H
6.28
1.63
3.85
4.23
1086
9
1354
13
7.92
2.10
3.78
1354
20
1700
34

031H
8.08
2.40
3.36
4.66

041H
10.37
2.39
4.34
4.64

1400

1795

16

19

9.54
2.44
3.90
1628
18
2064
34

12.46
3.13
3.98
2127
28
2746
46

051H
13.67
3.13
4.36
4.65
2372
14
2886
20
16.47
4.13
3.99
2813
28
3589
43

026HA
6.34
1.68
3.77
1086
69
1354
58
7.85
2.07
3.78
1354
60
1700
44

031HA
8.18
1.89
4.32
1400
64
1708
55
9.42
2.38
3.97
1628
60
2064
42

041HA
10.48
2.35
4.46
1795
57
2183
46
12.42
3.02
4.11
2127
47
2746
24

051HA
13.87
3.12
4.44
2372
85
2886
72
16.28
4.00
4.07
2813
73
3589
53

11

13

1708

2183

071HA
081HA
17.86
20.38
4.29
5.01
4.16
4.07
3055
3489
78
71
3770
4326
59
49
20.80
23.93
5.13
6.02
4.05
3.98
3591
4130
64
54
4569
5232
39
24
400V/3N/50Hz

(1) Data relating to the version with storage tank and pump "B" on geothermal side, pump "P" on utility side.
Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C;
Condenser water temperature (in/out) 30C/35C

348

Heating (14511:2013)
Evaporator water temperature (in/out) 10C/7C;
Condenser water temperature (in/out) 40C/45C

Technical Data
Mod. WRL - H (/A)
Electrical data

vers.
230V
400V
230V
400V
230V
400V
230V
400V

Total input current cooling mode


Total input current heating mode

Max. current (FLA)


Peck current (LRA)

(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

Compressor
Compressor

026

031

041

051

071

081

101

141

161

A
A
A
A
A
A
A
A

8.5
4.2
10.5
4.9
18
8
63
34

10.8
3.8
13.1
4.9
21
8
84
37

13.5
5.8
16.6
6.7
34
15
119
65

7.2
8.5
17
75

10.2
12.2
22
75

13.3
16.1
32
90

16.7
20.7
40
94

19.1
23.9
41
95

n/n

1
1

1
1

1
1

1
1

9.0
10.7
21
75
scroll
1
1
R410A

1
1

2
1

2
1

2
1

type
n

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

plate
1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

type
n

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

plate
1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

1
F / 1"/14

l
n/l
n/l
kPa

100
1/2
1/8

100
1/2
1/8

150
1/8
1/8

150
1/8
1/8

dB(A)
dB(A)

55,5
24,3

57,0
25,8

63,0
31,6

63,5
32,1

Circuit
Refrigerant
Heat exchanger system side
Exchanger

Connections
Heat exchanger geothermal side
Exchanger

Connections
Hydronic kit
Buffer tank
Expansion tank (with pump)
Expansion tank (with pump and buffer tank)
Useful head
Sound data
Sound power
Sound pressure

100
100
100
100
150
1/2
1/2
1/2
1/2
1/8
1/8
1/8
1/8
1/8
1/8
for more information, refer to the selection program
57,5
26,3

59,0
27,7

60,0
28,7

60,5
29,2

62,0
30,6

(2) The data of the versions without hydronic module integrated


Sound power (cooling mode)
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure (cooling mode)
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions (mm)

A
A

C
C

WRL101H-161H

WRL 026HA-081HA

WRL 101HA-161HA

WRL
Height (A)
Width (B)
Depth (C)
Weight

mm
mm
mm
kg

026H
976
605
603
120

031H
976
605
603
125

041H
976
605
603
130

051H
1126
605
773
150

071H
1126
605
773
170

081H
1126
605
773
180

101H
1126
1155
773
260

141H
1126
1155
773
270

161H
1126
1155
773
280

WRL
Height (A)
Width (B)
Depth (C)
Weight *

mm
mm
mm
Kg

026HA
1126
1155
773
190

031HA
1126
1155
773
200

041HA
1126
1155
773
210

051HA
1126
1155
773
230

071HA
1126
1155
773
250

081HA
1126
1155
773
260

101HA
1126
1755
773
340

141HA
1126
1755
773
350

161HA
1126
1755
773
360

* Weight with two heat exchangers and buffer tank without pumps.

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

349

Cod.: SWRLHUY.02 / 1503

WRL 051H-081H

WRL 026H-041H

WRL
180/650

Water cooled reversible heat pumps


for the production of hot water up to 55C
Cooling capacity from 45157kW
Heating capacity from 53184kW

reversible
refrigerant
c i r c u i t

Aermec participates in the EUROVENT


Programme: LCP
The products of interest
can be found on the website
www.eurovent-certification.com

PGD1
Simplified remote panel.
ACCESSORY

TAT - TAH
ACCESSORY

HIGH EFFICIENCIES
POSSIBILITY OF HAVING:
PARTIAL HEAT RECOVERY
PRODUCTION OF HOT WATER UP TO 55 C
SUITABLE FOR GEOTHERMAL APPLICATIONS
Characteristics
WRL is the range of water cooled chillers
operating with refrigerant R410A. They are
internal units with hermetic scroll compressors
that respond perfectly to the market
requirements: small dimensions, ease of installation, low noise.
High efficiency
Aermec has designed these units to optimise
heat pump operation, providing high performances and low energy consumption.
Connections
The electric and hydraulic connections are all
located on the upper part of the unit
facilitating installation and maintenance. This
allows reduced plant room space and installation in the smallest space possible.
Silent
The WRL units are distinguished for their
silence in operation. Careful soundproofing of
the unit with suitable sound-absorbent material results in low sound levels for all units.

350

Dynamic set point


Using the latest generation of electronic controller and with an external air temperature
sensor (accessory), the heat pump unit can
vary the leaving water temperature based on
climatic conditions, thus increasing the energy
efficiency of the system.
Advantages
Using the latest innovative technology and
focus on maximum quality gives the WRL
series the maximum energy efficiency, ease of
installation, and most versatile application
using renewable energy sources.
Range
Available in 8 sizes:
Reversible refrigerant side
Version
WRLH= Heat pump
Technical features
Structure and base in hot dip galvanised
sheet steel with epoxy paint finish (RAL

9002)
Generously sized plate heat exchangers
Compressors with high performance and
low electrical input
Flow switch as standard
Conforms with Safety Directives (CE) and
the standards regarding electromagnetic
compatibility
The safety of the unit is provided by the
door interlocked isolator and active protection of the main components
Externally mounted user interface with display of all operating parameters in 4 languages
Latest generation of electronic controller
User-friendly remote mounted control panel
with alarm notification.

Accessories
AER485P1: RS-485 interface for supervising
systems with MODBUS protocol.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:
- AERWEB300-6: Web server to monitor and
remote control max. 6 units in RS485 network;
- AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
- AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network with integrated GPRS modem;
VT: Anti-vibration mounts: four anti-vibration

mounts to be installed under the unit's steel


base.
TAT: Room temperature sensor, 230 Vac
recess mounted kit containing the ambient
sensor with display and control knob, able to
control an ON-OFF valve or a zone pump.
TAH: Room temperature and humidity sensor, 230 Vac recess mounted kit containing
the sensor with display and control knob,
able to control an ON-OFF valve or a zone
pump and
dehumidifier enable.
SSM: Sensor to be used together with the
mixing valve in applications with radiant
panels. Accessory to be requested together
with the VMFCRP zone accessory.
S...I: System buffer tanks: available in sizes
200, 300, 400 and 500 litres (S200I, S300I,
S400I and S500I).

PGD1: Simplified remote panel. Allows control


of basic unit functions and alarm notification.
Remote mounted up to 500 m away with
TWISTED PAIR SCREENED cable and
TCONN6J000.
KSAE: External air sensor. Temperature sensor
with plastic enclosure.
VMFCRP: WRL Zones Control can control
up to a maximum of 3 zones with the following modes:
- Zone 1: Controlled as standard with the
latest generation electronic controller. The
"SSM" clamp on sensor (accessory) is recommended to control the flow temperature.
- The control of the remaining Zone 2 and
Zone 3 is possible using the VMFCRP + SSM
accessories for each zone.

ACCESSORY COMPATIBILITY
WRLH
AER485P1
AERWEB300
VT
TAT
TAH
SSM
S...I (200-300-400-500)
PGD1
KSAE
VMFCRP

VMFCRP

180

200

300

400

500

15

550

15

600

15

650

15

Unit configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of
system requirements.

CODE:
WRL
SIZE:
180 - 200 - 300 - 400 - 500 - 550 - 600 - 650
FIELD OF USE:
- Standard with leaving water above +4 C
Y - Low temperature with leaving liquid down to -8 C
X - Electronic expansion valve with leaving liquid down to +4C
(for different temperature contact us)
MODEL:
H - Reversible refrigerant circuit
VERSION:
- Standard
HEAT RECOVERY
- Without heat recovery
D - Desuperheater
PUMPS (GEOTHERMAL SIDE)
- Without pump
B - Low static pressure pump
U - High static pressure pump
F - Low static pressure inverter pump
I - High static pressure inverter pump
V - 2-way modulating valve

PUMPS (SYSTEM SIDE)


- Without pump
P - Low static pressure pump
N - High static pressure pump
FIELD NOT USED

SOFT START
- Without Soft Start
S - Soft Start
POWER SUPPLY
- 400V-3N -50 Hz
5 - 500V-3-50Hz (only models WRL400-550-600-650)

351

Technical Data
WRL-H model
Cooling capacity
Kw
Input power
Kw
Input current
A
Evaporator water flow rate
l/h
Evaporator pressure drop
kPa
Condenser water flow rate
l/h
Condenser pressure drop
kPa
Heating capacity
Kw
Input power
Kw
Input current
A
Condenser water flow rate
l/h
Condenser pressure drop
kPa
Evaporator water flow rate
l/h
Evaporator pressure drop
kPa
Energy index
E.E.R.
W/W
E.S.E.E.R.
W/W
C.O.P.
W/W
Compressor
N circuits/N compressors
Capacity control
%
Geothermal side heat exchanger
Hydraulic connections

Quantity
n
System side heat exchanger
Hydraulic connections

Quantity
n
Desuperheater (optional)
Hydraulic connections

Quantity
n
Expansion vessel (versions with pumps)
Expansion vessel (per circuit)
n/l
Sound data

180
45
10,96
20
7740
20
9365
32
53
13,04
23
9113
30
12009
49

200
59
14,83
25
10286
37
12453
55
71
17,76
29
12175
52
16042
89

300
65
16,47
28
11180
37
13595
53
77
19,11
31
13154
49
17343
92

400
79
18,68
32
13726
55
16419
76
93
22,57
37
15913
72
21229
132

500
93
20,23
36
16030
25
19034
35
107
23,98
41
18298
32
24645
61

550
120
27,69
52
20709
40
24780
58
144
33,06
57
24705
58
33289
107

600
140
31,44
60
24166
40
28795
58
165
37,16
65
28247
56
38175
101

650
157
35,97
69
27142
50
32405
73
184
42,60
75
31523
70
42437
125

4,09
4,72
4,08

4,01
4,53
4,01

3,93
4,58
4,03

4,24
4,54
4,13

4,59
5,62
4,46

4,33
5,43
4,37

4,45
5,42
4,44

4,36
5,00
4,33

1/2
50/100

1/2
50/100

1/2
50/100

1/2
50/100

1/2
50/100

1/2
50/100

1/2
50/100

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

2
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1/8

1/8

1/8

1/8

1/12

1/12

1/12

SCROLL
1/2
50/100
PLATES
2
1
PLATES
2
1
PLATES
1
1
1/12

Sound power

dB(A)

61.1

61.8

62.9

71.1

67.6

79.1

79.1

79.1

Sound pressure

dB(A)

29.1

29.8

30.9

39.1

35.6

47.1

47.1

47.1

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; Condenser water temperature (in/out) 30C/35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C; Evaporator water temperature (in/out) 10C/7C
The electrical data of the versions without hydronic module integrated
Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

352

Dimensions (mm)

B
C

WRLH 180-400

mm
mm
mm
kg

180
1380
1320
845
370

200
1380
1320
845
370

300
1380
1320
845
381

400
1380
1320
845
388

500
1380
2060
845
522

550
1380
2060
845
598

600
1380
2060
845
708

650
1380
2060
845
753

Code : SWRLH2UY.04 / 1503

WRLH Model
Height (A)
Width (B)
Depth (C)
Weight empty

WRLH 500-650

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

353

NXW
0500/1400

Water cooled internal chiller and heat pump units with scroll compressors
Cooling capacity 106kW385kW
Heating capacity 119kW434kW

Aermec adheres to the EUROVENT


Certification Programme: LCP
The products concerned appear in the
EUROVENT Certified Products Guide.

HIGH EFFICIENCY
HEAT PUMP WITH REFRIGERANT SIDE REVERSING FOR GEOTHERMAL APPLICATIONS
OPTION OF 1 OR 2 PUMPS ON BOTH EVAPORATOR AND CONDENSER SIDE
PRODUCTION OF HOT WATER UP TO 55 C

Characteristics
NXW is the range of water cooled heat
pumps that operate with refrigerant R410a.
They are internal units with hermetic scroll
compressors that respond perfectly to the market requirements: small dimensions, ease of
installation, low noise.
Maximum energy efficiency
For years Aermec has been attentive to the
energy efficiency issue, and has now
designed the NXW units with the aim of
ensuring high efficiency levels with both full
and partial loads.
Models available
NXW: water side reversible heat pump
NXWH: refrigerant side reversible heat pump

All models are available in low noise version


Integrated hydronic module on system side/
on geothermal side
The built-in hydronic module includes the
main water circuit components; it is available
in varius configurations with one or two
pumps with high or low head both on the
system side and the geothermal side.
Advanced controls
The NXW controller provides several
functions:
- Two chiller units in parallel (run/standby)
- Programmed pump rotation
- Inverter condenser pump control to manage
the condensing pressure
- Programmable time-clock
- Automatic water set point compensation
- Data logging

Construction details:
Structure and base in hot dip galvanised sheet
steel with epoxy pain finish (RAL 9002)
High efficiency plate heat exchangers
Compressors with high performance and
low electrical input
High and low pressure transducers as
standard
Conforms with Safety Directives (CE) and
the standards regarding electromagnetic
compatibility
The safety of the unit is provided by the
door interlocked isolator and active protection of the main components
Externally mounted user interface with display of all operating parameters in 4 languages
User-friendly remote mounted control panel
with alarm notification.

Accessories
AER485P1: RS-485 interface for supervision

systems with MODBUS protocol.


AERWEB300: Accessory AERWEB allows remote
control of a chiller through a common PC and
an ethernet connection over a common browser;
4 versions available:
AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and
remote control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and
remote control max. 6 units in RS485 network
with integrated GPRS modem;

354

AERWEB300-18G: Web server to monitor and


remote control max. 18 units in RS485 network
with integrated GPRS modem;
MULTICHILLER_NXW: Control system to
switch the individual chillers on and off,
and command them, in a system in which
several units are installed in parallel, always
ensuring a constant delivery to the exchanger.
PGD1: In addition to the unit mounted controller on the NXW unit a remote mounted
PGD1 panel can be supplied providing the
same functions (keyboard controls and dis-

play).
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current. Must be requested at time of order and is available factory
fitted only.
AVX: spring anti-vibration mounts.
DRE: Soft starter (current reduction of about
30% for single circuit units, 26% for two
circuit units, 22% for three circuit units).
Only available for 400V-3-phase power
supply. Factory fitted only.

Accessory Compatibility
NXW
VERS.
AER485P1
Alls
AERWEB300
Alls
MULTICHILLER_NXW
Alls
PGD1
Alls
AVX
Water side reversible heat pump ""

With n1 pumps

With n2 pumps

With n3 pumps

With n4 pumps

refrigerant side reversible heat pump "H"


With n1 pumps

With n2 pumps

With n3 pumps

With n4 pumps

Water side reversible heat pump ""


With n1 pumps
L
With n2 pumps
L
With n3 pumps
L
With n4 pumps
L
refrigerant side reversible heat pump "H"
With n1 pumps
L
With n2 pumps
L
With n3 pumps
L
With n4 pumps
L
Evaporating unit "E"
With n1 pumps
With n2 pumps
With n3 pumps
With n4 pumps
Evaporating unit low nois versions "LE"
With n1 pumps
With n2 pumps
With n3 pumps
With n4 pumps
Model with total heat recovery "T"
Model with total heat recovery low nois versions "LT"
RIF
Alls
DRE
Alls

0500

0550

0600

0650

0700

0750

0800

0900

1000

1250

1400

319
320
320
320
309
319
320
320
309
309
309
321
311
311
312
309
311
311
312
312
319
320
320
320
309
309
321
311
311
312
303
312
98
501

319
320
320
320
309
319
320
320
309
309
309
321
311
311
312
309
311
311
312
312
319
320
320
320
309
309
321
311
311
312
303
312
98
551

301
320
309
309
310
301
320
303
303
312
310
311
31
312
312
310
311
312
312
312
301
320
309
309
310
310
311
31
312
312
310
651
95
601

301
320
309
309
310
301
309
309
311
312
303
311
311
312
310
303
311
313
313
313
301
320
309
309
310
303
311
311
312
310
310
651
95
651

301
320
309
309
310
302
309
311
312
312
303
651
651
651
651
304
651
651
651
651
301
320
309
309
310
303
651
651
651
651
310
652
95
701

303
312
312
312
312
310
651
651
651
651
310
651
651
651
651
314
652
652
652
652
303
312
312
312
312
310
651
651
651
651
314
652
95
751

310
651
651
651
651
310
651
651
651
651
314
652
652
652
652
314
665
665
665
665
310
651
651
651
651
314
652
652
652
652
652
652
95
801

314
665
665
665
665
314
665
665
665
665
314
653
653
653
653
315
653
653
653
653
314
665
665
665
665
314
653
653
653
653
315
323
96
901

316
653
653
653
653
316
654
654
654
654
315
654
654
654
654
317
659
659
659
659
316
653
653
653
653
315
654
654
654
654
322
324
97
1001

316
654
654
654
654
315
654
654
654
654
315
659
659
659
659
317
659
659
659
659
316
654
654
654
654
315
659
659
659
659
322
324
97
1251

315
654
654
654
654
317
654
654
654
654
317
659
659
659
659
318
659
659
659
659
315
654
654
654
654
317
659
659
659
659
322
324
97
1401

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding
of system requirements.
Code:
NXW
Size:
0500, 0550, 0600, 0650, 0700, 0750, 0800, 0900, 1000, 1250, 1400
Field of use:
- Thermostatic expansion valve with leaving water above +4 C
Y - Thermostatic expansion valve for low leaving liquid down to -8 C
X - Electronic thermostatic valve, max. temp. of water produced: +4C
(for lower temperatures please contact us)
Model:
- water side reversible heat pump
H - refrigerant side reversible heat pump
Version:
- Standard
L - Low Noise
Evaporator:
- Standard
E - Evaporating unit (shipped with holding charge only)
Heat recovery:
Without heat recovery
D With desuperheaters (partial heat recovery)
T With total heat recovery

Power supply:
- 400V 3~ 50Hz with circuit breakers
4 - 220V 3~ 50Hz with circuit breakers*
5 - 500V 3 50Hz with circuit breakers**
Evaporator side pumps
- without pumps
M - low head pump
N - low head pump and standby pump
O - high head pump
P - high head pump and standby pump
Condenser side pumps
- without pumps
U - low head pump
V - low head pump and standby pump
W - high head pump
Z - high head pump and standby pump
J - low head inverter pump
K - high head inverter pump

Combinations not possible: YD, YT, HE, HT, ET, T with


evaporator or condenser side pumps.

* only available for sizes 0500-0700


** only available for sizes 0800-1400
*** "evaporator" is the heat exchanger that works as such in cooling; "condenser" is the heat exchanger that works as such in heating

355

Technical Data
Model NXW - NXW L
Size
Cooling capacity (E)
Total input power (E)
E.E.R. (E)
E.S.E.E.R.
Total current input
Evaporator water flow rate
Pressure drops user side
Condenser water flow rate
Pressure drops source side
Heating capacity
Total input power
COP
Total current input
Condenser water flow rate
Pressure drops user side
Evaporator water flow rate
Pressure drops source side
ELECTRICAL DATA
Maximum current (FLA)
Starting current (LRA)

400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3

kW
kW
W/W
A
l/h
kPa
l/h
kPa
kW
kW
W/W
A
l/h
kPa
l/h
kPa

0500
112
23.08
4.83
6,01
48.30
19264
30
22891
25
119
27.16
4.39
53.3
20468
20
16138
21

0550
120
24.93
4.83
6,02
50.60
20812
35
24717
29
129
29.37
4.41
56.2
22188
23
17515
25

0600
148
30.65
4.84
6,01
58.40
25628
32
30448
29
161
36.59
4.41
66
27692
24
21859
23

0650
166
34.36
4.84
6,04
63.00
28724
40
34100
37
182
41.13
4.42
72.0
31215
31
24596
29

0700
188
38.93
4.83
6,02
86.00
32508
43
38603
37
205
46.75
4.39
94.0
35195
31
27763
31

750
222
45.59
4.87
6,05
94.00
38356
47
45480
45
243
55.09
4.41
105.0
41624
38
32882
34

800
257
53.00
4.85
6,03
102.00
44376
49
52611
60
280
63.75
4.40
115.0
47988
50
37890
36

900
291
60.28
4.82
6,02
120.00
50224
55
59669
38
319
72.25
4.41
135.0
54696
32
43143
41

1000
325
66.51
4.89
6,06
138.00
56072
35
66611
29
357
80.80
4.42
154.0
61232
25
48291
26

1250
354
72.63
4.87
6,05
140.00
61060
36
72547
34
389
87.98
4.42
160.0
66736
29
52651
27

1400
384
78.66
4.88
6,06
143.00
66220
36
78655
36
420
95.11
4.41
165.0
72068
30
56839
27

400V/3
400V/3

A
A

75
240

80
245

96
227

107
238

122
289

146
319

169
341

193
398

217
422

231
490

248
504

Data declared in accordance with EN 14511:2014 - (E) EUROVENT for reversible units on the water side certies the sun made cold (12-7C - 30-35C)
Cooling:
User side water temperatures (in/out)
Source side water temperatures (in/out)

Model NXW H - NXW HL


Size
Cooling capacity
Total input power
E.E.R.
E.S.E.E.R.
Total current input
Evaporator water flow rate
Pressure drops user side
Condenser water flow rate
Pressure drops source side
Heating capacity
Total input power
COP
Total current input
Condenser water flow rate
Pressure drops user side
Evaporator water flow rate
Pressure drops source side
ELECTRICAL DATA
Maximum current (FLA)
Starting current (LRA)

Heating:
User side water temperatures (in/out)
Source side water temperatures (in/out)

12C/7C
30C/35C

40C/45C
10C/5C

400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3
400V/3

kW
kW
W/W
A
l/h
kPa
l/h
kPa
kW
kW
A
l/h
kPa
l/h
kPa

0500
105.71
23.92
4.42
5,73
49
18232
17
22023
25
125.61
27.96
4.49
53.3
21536
24
28589
43

0550
113.66
25.84
4.40
5,71
52
19608
20
23693
29
136.04
30.32
4.49
56.2
23316
28
30965
49

0600
140.62
31.24
4.50
5,76
60
24252
19
29203
28
166.09
36.86
4.51
65.1
28478
26
37822
46

0650
159.52
35.39
4.51
5,85
65
27520
24
33108
35
187.97
41.75
4.50
71.0
32216
33
42843
58

0700
180.47
40.20
4.49
5,76
87
31132
24
37488
35
210.77
46.94
4.49
92.7
36130
32
47999
58

750
211.33
47.13
4.48
5,79
95
36464
29
43899
42
270.08*
55.60*
4.86
105.01
37475
31
46267
46

800
242.12
54.23
4.46
5,64
104
41796
38
50293
55
310.89*
64.58*
4.81
115.01
43059
40
53207
61

900
277.29
62.17
4.46
5,72
122
47816
24
57865
36
325.88
72.55
4.49
133.1
55886
33
74186
58

1000
313.35
70.41
4.45
5,85
140
54008
19
65250
28
366.17
80.76
4.53
151.9
62828
26
83446
46

1250
341.23
76.61
4.45
5,77
144
58824
22
71030
32
400.48
88.67
4.52
157.8
68702
30
91221
52

1400
369.14
82.74
4.46
5,80
147
63640
24
76810
34
434.77
96.49
4.51
162.7
74576
32
99023
58

400V/3
400V/3

A
A

75
240

80
245

75
240

107
238

122
289

146
319

169
341

193
398

217
422

231
490

248
504

Data declared in accordance with EN 14511:2013


Cooling:
User side water temperatures (in/out)
Source side water temperatures (in/out)
Heating:
User side water temperatures (in/out)
Source side water temperatures (in/out)

Model NXW E - NXW EL


Size
Cooling capacity
Total input power
E.E.R.
Total current input
Evaporator water flow rate
Pressure drops user side
ELECTRICAL DATA
Maximum current (FLA)
Starting current (LRA)
COOLING LINES (0 - 10 m.)
Delivery line (C1+C2)
Liquid line (C1+C2)

400V/3
400V/3
400V/3
400V/3
400V/3
400V/3

400V/3
400V/3

Cooling:
User side water temperatures (in/out)
Condensing temperature
t

356

12C/7C
30C/35C

(*) Heating:
User side water temperatures (in/out)
Source side water temperatures (in/out)

40C/45C
10C/5C

40C/45C
10C/7C

kW
kW
W/W
A
l/h
kPa

0500
105
24.9
4.22
54.1
18031
26

0550
113
26.8
4.23
56.7
19480
31

0600
139
33.0
4.22
65.4
23988
28

0650
156
36.9
4.24
70.6
26918
35

0700
177
41.7
4.23
96.3
30381
38

750
209
48.8
4.28
105.3
35935
41

800
241
56.5
4.27
114.2
41488
43

900
273
64.7
4.22
134.4
46976
48

1000
305
72.3
4.22
154.6
52463
31

1250
332
78.8
4.22
156.8
57187
32

1400
360
85.3
4.22
160.2
61909
32

A
A

75
240

80
245

96
227

107
238

122
289

146
319

169
341

193
398

217
422

231
490

248
504

mm
mm

28/22
28/22

28/22
28/22

28/28
28/28

28/28
28/28

28/28
28/28

28/28
28/28

28/28
28/28

35/28
35/28

35/35
35/35

35/42
35/35

42/42
35/35

12C/7C
45C
5C

Technical Data
Size
compressors
N compressors/ Ncircuits
Evaporator
Hydraulic connection ""
Hydraulic connection "H"
Quantity
Condenser
Hydraulic connection ""
Hydraulic connection "H"
Quantity
Expansion vessel
n/capacity
Calibration
Sound data

0500

0550

0600

0650

0700

n/n

3/2

3/2

4/2

4/2

4/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

1000

1250

1400

4/2

4/2

4/2

4/2

4/2

2"1/2

2"1/2

2"1/2
3"

3"

3"

3"

2"1/2

3"
3"

3"

3"

3"

2"1/2

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

1/25
1,5

78
72
46
40

79
73
47
41

79
73
47
41

80
74
48
42

82
76
50
44

86
80
54
48

88
82
56
50

88
82
56
50

88
82
56
50

90
84
58
52

90
84
58
52

dB(A)

Sound pressure

900

/H
L/HL
/H
dB(A)
L/HL

Sound power

800

1
Plate
2"1/2

n/l
bar

750
Scroll
4/2
Plate

Sound power:
Aermec determines sound power values on the basis of measurements made in accordance
with UNI EN ISO 9614-2, as required for Eurovent certication.

Sound pressure:
Sound pressure in free eld, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)
Mod. NXW / H / E
Height
Width
Length

A
B
C

H
E

Weight

Mod. NXW L / HL / EL
Height
A
Width
B
Length
C
L
Weight
HL
EL
Mod. NXW / NXW H POMPE
Height
A
Width
B
Length
C
Weight

mm
mm
mm
kg

mm
mm
mm
kg

mm
mm
mm
kg

Mod. NXW L/ NXW HL POMPE


Height
A
mm
Width
B
mm
Length
C
mm
Weight
kg

0500
1835
800
1795
578
628
525

0550
1835
800
1795
582
633
530

0600
1835
800
1795
682
734
610

0650
1835
800
1795
690
743
619

0700
1835
800
1795
727
791
638

750
1775
800
2420
882
948
796

800
1775
800
2420
989
1042
904

900
1820
800
2420
1180
1275
1044

1000
1820
800
2420
1417
1545
1260

1250
1820
800
2420
1461
1577
1304

1400
1820
800
2420
1539
1657
1358

0500
1885
800
2090
750
801
697

0550
1885
800
2090
755
805
702

0600
1885
800
2090
854
907
781

0650
1885
800
2090
863
915
791

0700
1885
800
2090
900
963
810

750
1885
800
2420
1054
1121
968

800
1885
800
2420
1187
1240
1104

900
1885
800
2420
1378
1473
1244

1000
1885
800
2420
1615
1743
1460

1250
1885
800
2420
1659
1774
1504

1400
1885
800
2420
1737
1855
1558

0500
1775
800
3020

0550
1775
800
3020

0600
0650
0700
750
800
900
1000
1775
1775
1775
1775
1775
1820
1820
800
800
800
800
800
800
800
3020
3020
3020
3480
3480
3480
3480
The weight is variable depending on the chosen hydronic kit

1250
1820
800
3480

1400
1820
800
3480

0500
1885
800
3020

0550
1885
800
3020

0600
0650
0700
750
800
900
1000
1885
1885
1885
1885
1885
1885
1885
800
800
800
800
800
800
800
3020
3020
3020
3480
3480
3480
3480
The weight is variable depending on the chosen hydronic kit

1250
1885
800
3480

1400
1885
800
3480

Cod.: SNXWUY.07 / 1501

A
C

C
B

The technical data in this documentation are not binding. Aermec


S.p.A. shall have the right to introduce at any time whatever
modifications deemed necessary for the improvement of the
product.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

357

WSA

Water cooled chillers and heat pumps for indoor installation


with twin-rotor screw compressor and plate exchanger
Cooling capacity from 146712kW
Heating capacity from 161771kW

R134a
Aermec
participates in the EUROVENT
Program: LCP
The products of interest can be
found on the website
www.eurovent-certication.com

Characteristics
Versions for cooling only, heat pump or evaporating unit (delivered with holding charge
only)
Partial or total heat recovery options
Standard Version ():
- leaving water temperature up to 55 C in heat
pump mode
Version L:
- Low noise with sound absorbent galvanised
sheet panels
High efficiency, low noise screw compressors
with modulating capacity control from 40 to
100% with standard thermostatic expansion
valve. (25 to 100% with electronic expansion
valve option)
Compressor discharge and liquid line isolating valves
Current transformer as standard for each compressor

Dual refrigerant circuit plate heat exchanger


optimised for R134a on dual compressor
units
Modulating capacity control microprocessor
system
Independent control for individual circuits
Electrical panel with all cables numbered
Modulating capacity control with dynamic
display of refrigeration capacity
Always Working function. In the case of
critical conditions the unit will not stop but
automatically adjusts operation
Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor
Auto-adaptive differential to ensure correct
compressor operating timers
PDC (Pull Down Control) system which prevents capacity loading when the water tem-

perature quickly approaches the set point


DL (Demand Limit) system permits current
limiting of the unit during times of insufficient
electrical power (load peaks or generator
operation)
Compact dimensions
Multilingual display panel
Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
PRV3: Remote control of the chiller operating
functions.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current. Must be requested
at time of order and is available factory fitted
only.
AVX: Spring anti-vibration mounts.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a
common browser; 4 versions available:

358

- AERWEB300-6: Web server to monitor and MULTICHILLER: Control system for multiple
remote control max. 6 units in RS485 netparallel installed constant flow chillers prowork;
viding individual chiller on/off and control
- AERWEB300-18: Web server to monitor and
capability.
remote control max. 18 units in RS485 net- AKW: ACOUSTIC KIT: Allows further unit
work;
sound reduction using an optimised enclosure
- AERWEB300-6G: Web server to monitor and
made from a high density ecological material.
remote control max. 6 units in RS485 network with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network with integrated GPRS modem;
SAP: A series of remote buffer tanks and pumps
are available. Refer to the technical manual.

Accessory compatibility
Mod
Vers.
AERWEB300
MULTICHILLER
AER485P1
RIF
PRV3
/L
E
D
AVX
DE
T
AKW

0601

651

0701

0801

0901

1101

1202

(x2)

1402

(x2)

1602

(x2)

1802

(x2)

2002

(x2)

2202

(x2)

2502

(x2)

2802

(x2)

161

161

201

651
668
651
668
652

652
668
652
668
655

652
668
652
668
655

241

161(x2)

161(x2)

201(x2)

201-241

241(x2)

301(x2)

301(x2)

656
669
654
669
657

658

658
670
658
670
662

658
670
659
670
662

659
670
659
670
662

667
671
667
671
663

661
672
661
672
664

661
672
661
672
664

661
672
661
672
664

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Code:
WSA
Size:
601, 0701, 0801, 0901, 1101, 1202, 1402, 1602, 1802, 2002, 2202,
2502, 2802
Expansion device:
- Standard, minimum leaving water temperature down to +4 C
X - With electronic expansion valve max. temp. of water produced:
+4C (for lower temperatures please contact us)
Model:
- Standard
Heat recovery:
- Without heat recovery
D - With desuperheaters (partial heat recovery)
(not available for the size 0601 and 1202)
T - With total heat recovery
(not available for the size 0601 and 1202)
Version:
- Standard
L - Low noise
Condenser:
- PED regulation
E - Evaporating unit (delivered with holding charge only)
Power supply:
- 400V 3~ 50Hz with fuses
8 - 400V 3~ 50Hz with circuit breakers
2 - 230V 3~ 50Hz with fuses *
4 - 230V 3~ 50Hz with circuit breakers *
* (not available for sizes 2502 and 2802)
5 - 500V 3~ 50Hz with fuses
9 - 500V 3~ 50Hz with circuit breakers
Attention: The standard options are shown by the symbol
Example of configuration code: WSA1602L8
This is a WSA unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at
400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in
the unit configurator.

359

Technical Data
Mod WSA
Cooling capacity (E)
kW
Total input power (E)
kW
Water flow rate evaporator
l/h
Pressure drop evaporator
kPa
Water flow rate condenser
l/h
Pressure drop condenser
kPa
Heating capacity
kW
Total input power
kW
Water flow rate condenser
l/h
Pressure drop condenser
kPa
Water flow rate evaporator
l/h
Pressure drop evaporator
kPa
E.E.R. (E)
W/W
EEEC(1)
C.O.P
W/W
EEEC(1)
Power supply
Input current cooling
A
Input current heating
A
Maximum current (FLA)
A
Starting current (LRA)
A
Compressor
Type
Quantity
n
Part load (standard expansion valve)
%
Part load (electronic expansion valve)
%
Evaporator
Type
Quantity
n
Evaporator hydraulic connection

Hydraulic connection type


Type
Condenser
Type
Quantity
n
Condenser hydraulic connection

Hydraulic connection type


Type
Sound pressure(2)
dB(A)

0601

0701

0801

0901

1101

1202

1402

1602

146
31,75
25284
29
30268
40
161
36,93
27520
31
21638
19
4,61
B
4,35
B

179
38,10
30788
20
36834
27
192
44,08
32852
41
25826
12
4,69
B
4,35
B

212
43,24
36636
20
43499
27
219
48,85
37496
20
29653
12
4,91
A
4,47
A

233
49,28
40248
19
48091
26
246
56,89
42140
19
32990
12
4,74
B
4,32
B

293
59,68
50568
23
60045
31
309
71,20
52976
24
41538
14
4,91
A
4,34
B

293
63,52
50568
38
60535
53
320
73,83
54868
42
43103
25
4,61
B
4,34
B

356
76,83
61404
36
73496
50
376
87,85
64500
36
50448
22
4,63
B
4,28
B

422
468
527
586
660
712
86,53 101,02 110,73 120,50 137,70 148,19
72756 80840 90988 101136 114036 122980
40
41
45
48
53
62
86318 96690 108308 119927 135441 145856
55
58
62
67
75
88
435
493
559
627
690
771
99,22 113,57 129,03 143,58 155,22 178,00
74648 84452 95804 107500 118164 131924
39
42
46
50
55
74
58798 66315 75216 84624 93491 103819
24
25
27
29
32
44
4,87
4,64
4,76
4,86
4,80
4,80
A
B
B
A
A
A
4,39
4,34
4,33
4,37
4,44
4,33
A
B
B
A
A
A

1802

2002

2202

2502

2802

56
67
105
180

66
73
124
163

74
82
144
192

82
91
162
229

101
117
182
300

112
133
210
285

1
40-100
25-100

1
40-100
25-100

1
40-100
25-100

1
40-100
25-100

1
40-100
25-100

1
3"

1
3

1
3

1
3

1
3

400V/3/50Hz
132
146
248
287

148
164
288
336

164
183
324
391

184
209
344
462

203
235
364
482

233
257
430
575

233
258
430
575

Twin-rotor screw
2
2
2
2
2
2
2
2
20-100 20-100 20-100 20-100 20-100 20-100 20-100
20-100
12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100

Plate
1
3"

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

57

61

63

63

63

Victaulic
Plate
1
3

1
3

1
3

1
3

1
3

1
3"

1
3

53

54

54

54

60

56

57

Victaulic
57

Data declared in accordance with UNI EN 14511:2013


(E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C)
Mod WSA - E
Cooling capacity
Total input power
Water flow rate evaporator (7 C)
Pressure drop evaporator
E.E.R.
EEEC(1)
Power supply
Input current cooling
Maximum current (FLA)
Starting current (LRA)
Compressor
Quantity
Part load (standard expansion valve)
Part load (electronic expansion valve)
Evaporator
Quantity
Evaporator hydraulic connection
Hydraulic connection type
Sound pressure(2)

kW
kW
l/h
kPa
W/W

A
A
A
Type
n
%
%
Type
n

Type
dB(A)

0701
163
41
28040
18
3.98
A

0801
192
47
33020
18
4.09
A

0901
212
54
36460
17
3.93
A

1101
263
66
45240
21
3.98
A

1402
1602
1802
2002
2202
2502
2802
326
385
428
481
539
601
676
82
93
108
120
132
146
159
56070 66220 73620 82790 92710 103370 116270
33
37
38
40
45
49
59
3.98
4.14
3.96
4.00
4.08
4.12
4.25
A
A
A
A
A
A
A
400V 3~ 50 Hz
72
81
90
113
144
162
180
204
226
254
272
124
144
162
182
248
288
324
344
364
430
430
163
192
229
300
287
336
391
462
482
575
575
Twin-rotor screw
1
1
1
1
2
2
2
2
2
2
2
40-100 40-100 40-100 40-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100
25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100
Plate
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
Victaulic
54
54
54
60
57
57
57
63
63
63
63

The sizes 0601 and 1202 is not available without condenser


(1) EEEC EUROVENT energy efficiency class
(2) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744.

Cooling:
leaving water temperature 7 C
entering condenser water temperature 30 C
't = 5K

Evaporating unit:
leaving evaporator water temperature 7 C
refrigerant condensing temperature 45 C
't = 5K

360

Heating:
leaving water temperature 45 C
entering evaporator water temperature 10 C
't = 5 K

Dimensions (mm)

Mod WSA (E - L)
Height (A) - E
Height (A) L - LE
Width (B)
Length (C)
Weight

0601
1775
1775
810
2960
1101
1229
-

0701
1775
1775
810
2960
1251
1379
1479

0801
1775
1775
810
2960
1301
1429
1529

0901
1775
1775
810
2960
1357
1485
1585

1101
1775
1775
810
3360
1788
1934
2045

1202
1975
2120
810
2960
1738
1966
-

1402
1975
2120
810
2960
2028
2256
2256

1602
1975
2120
810
2960
2097
2325
2325

1802
2005
2120
810
2960
2169
2397
2397

2002
1985
2120
810
3360
2598
2855
2855

2202
2065
2120
810
3360
3000
3257
3257

2502
2065
2120
810
3360
3095
3352
3352

2802
2065
2120
810
3360
3095
3352
3352

mm
mm
mm
mm
kg

0601T 0701 T 0801 T 0901 T 1101 T 1202T 1402 T 1602 T 1802 T 2002 T 2202 T 2502 T 2802 T
2000
2000
2000
2000
2050
2050
2050
2050
2065
2065
2065
2120
2120
2120
2120
2120
2120
2120
2120
2120
2120
2120
810
810
810
810
1250
1250
1250
1250
1250
1250
1250
2960
2960
2960
3360
3060
3060
3060
3460
3460
3460
3460
1479
1529
1585
2045
2294
2363
2435
2894
3296
3391
3391

Cod.: SWSAUY.17 / 1501

Mod WSA ( - L)
Height (A)
Height (A) L
Width (B)
Length (C)
Weight

mm
mm
mm
mm
kg ()
kg (L)
kg (D/DE)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

361

WSB

Water cooled chillers and heat pumps with twin-rotor screw compressor
Cooling capacity from 171701kW
Heating capacity from 185743kW

R134a

Aermec
participates at EUROVENT
program: LCP
The involved products can be
found in the website
www.eurovent-certification.com

Characteristics
Versions for cooling only, heat pump or evaporating unit (delivered with holding charge
only)
Partial or total heat recovery options
Standard Version ():
- leaving water temperature up to 55 C in heat
pump mode
Version L:
- Low noise with sound absorbent galvanised
sheet panels
High efficiency, low noise screw compressors
with modulating capacity control from 40 to
100% with standard thermostatic expansion
valve. (25 to 100% with electronic expansion
valve option)
Compressor discharge and liquid line isolating valves
Current transformer as standard for each com-

pressor
Dual refrigerant circuit plate heat exchanger
optimised for R134a on dual compressor
units
Modulating capacity control microprocessor
system
Independent control for individual circuits
Electrical panel with all cables numbered
Modulating capacity control with dynamic
display of refrigeration capacity
Always Working function. In the case of
critical conditions the unit will not stop but
automatically adjusts operation
Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor
Auto-adaptive differential to ensure correct
compressor operating timers

PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point
DL (Demand Limit) system permits current
limiting of the unit during times of insufficient
electrical power (load peaks or generator
operation)
Compact dimensions
Multilingual display panel
Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision
systems with MODBUS protocol.
PRV3: Remote control of the chiller operating
functions.
RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time
of order and is available factory fitted only.
AVX: Spring anti-vibration mounts.
AERWEB300: Accessory AERWEB allows
remote control of a chiller through a common PC and an ethernet connection over a

362

common browser; 4 versions available:


work with integrated GPRS modem;
- AERWEB300-6: Web server to monitor and SAP: A series of remote buffer tanks and pumps
remote control max. 6 units in RS485 netare available. Refer to the technical manual.
work;
MULTICHILLER: Control system for multiple
- AERWEB300-18: Web server to monitor and
parallel installed constant flow chillers providremote control max. 18 units in RS485 neting individual chiller on/off and control capawork;
bility.
- AERWEB300-6G: Web server to monitor and AKW: ACOUSTIC KIT: Allows further unit
remote control max. 6 units in RS485 netsound reduction using an optimised enclosure.
work with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 net-

Accessory compatibility
Mod
Vers.
AERWEB300
MULTICHILLER
AER485P1
RIF
PRV3
/L
E
D
AVX
T
DE
AKW

0701

161

651
668
651
651
668

0801

161

651
668
651
652
668

0901

201

651
668
652
652
668

1101

241

653
669
653
654
669

1402

(x2)
161(x2)

656
670
658
662
670

1602

(x2)
161(x2)

658
670
658
662
670

1802

(x2)
201(x2)

658
670
659
662
670

2002

(x2)
201-241

667
671
667
663
671

2202

(x2)
241(x2)

660
672
660
664
672

2502

(x2)
301(x2)

661
672
661
664
672

2802

(x2)
301(x2)

661
672
661
664
672

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Configuration Fields:
123
|
Code

4567
8
9
10
11
|
|
|
|
|
| Expansion device |
Heat recovery
|
|
|
|
Size
Model
Version

Code:
WSB
Size:
0701, 0801, 0901, 1101, 1402, 1602, 1802, 2002, 2202, 2502, 2802
Expansion device:
- Standard, minimum leaving water temperature down to +4 C
X - With electronic expansion valve
Model:
- Standard
Heat recovery:
- Without heat recovery
D - With desuperheaters (partial heat recovery)
T - With total heat recovery
Version:
- Standard
L - Low noise

12
|
Condenser

13
|
|
|
Power supply

Condenser:
- PED regulation
E - Evaporating unit (delivered with holding charge only)
Power supply:
- 400V 3~ 50Hz with fuses
8 - 400V 3~ 50Hz with circuit breakers
2 - 230V 3~ 50Hz with fuses *
4 - 230V 3~ 50Hz with circuit breakers *
* (not available for sizes 2502 and 2802)
5 - 500V 3~ 50Hz with fuses
9 - 500V 3~ 50Hz with circuit breakers

Attention: The standard options are shown by the symbol


Example of configuration code: WSB1602L8
This is a WSB unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at
400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by )
in the unit configurator.

363

Technical Data
Mod WSB
Cooling capacity (E)
Total input power (E)
Water flow rate evaporator
Pressure drop evaporator
Water flow rate condenser
Pressure drop condenser
Heating capacity
Total input power
Water flow rate condenser
Pressure drop condenser
Water flow rate evaporator
Pressure drop evaporator
E.E.R. (E)
EEEC(1)
C.O.P.
EEEC(1)
Power supply
Input current cooling
Input current heating
Maximum current (FLA)
Starting current (LRA)
Compressor
Quantity
Part load (standard expansion valve)
Part load (electronic expansion valve)
Evaporator
Quantity
Evaporator hydraulic connection
Hydraulic connection type
Condenser
Quantity
Condenser hydraulic connection
Hydraulic connection type
Sound pressure

1402
1602
1802
343
395
451
77,77
88,57 101,96
59168 68284 77916
52
57
54
71260 82010 93766
73
79
77
362
418
475
89,42 100,85 115,12
62092 71724 81528
54
57
56
47876 55711 63227
31
34
33
4,40
4,46
4,42
B
B
B
W/W
4,05
4,14
4,13
B
B
B
400V 3~ 50Hz
A
66
74
82
102
132
149
165
A
73
82
91
118
147
166
184
A
124
144
162
182
248
288
324
A
163
192
229
300
287
336
391
Type
Twin-rotor screw
n
1
1
1
1
2
2
2
%
40-100 40-100 40-100 40-100 20-100 20-100 20-100
%
25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100
Type
Plate
n
1
1
1
1
1
1
1

3
3
3
3
3
3
3
Type
Victaulic
Type
Plate
n
1
1
1
1
1
1
1

3
3
3
3
3
3
3
Type
Victaulic
dB(A)
58
58
59
60
61
61
62

kW
kW
l/h
kPa
l/h
kPa
kW
kW
l/h
kPa
l/h
kPa
W/W

0701
171
38,75
29584
40
35630
56
185
45,21
31648
41
24458
24
4,42
B
4,09
B

0801
200
43,75
34572
35
41435
48
211
50,21
36292
35
28285
21
4,58
B
4,21
B

0901
225
50,73
38872
30
46879
42
241
57,22
41452
31
32302
19
4,44
B
4,22
B

1101
280
60,23
48332
34
57809
47
304
72,55
52116
36
40515
21
4,65
B
4,18
B

2002
505
112,60
87204
56
104688
79
541
130,76
92880
63
72128
34
4,48
B
4,14
B

2202
564
123,34
97352
58
116470
82
607
145,18
104232
62
81193
36
4,57
B
4,18
B

2502
645
139,03
111456
57
133025
81
679
157,44
116444
59
91444
35
4,64
B
4,31
B

2802
701
148,65
121088
67
143964
95
743
179,19
127452
80
99184
47
4,71
B
4,15
B

184
210
344
462

205
237
364
482

233
259
430
575

233
259
430
575

2
2
2
2
20-100 20-100 20-100 20-100
12,5-100 12,5-100 12,5-100 12,5-100

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

63

63

63

63

Data declared in accordance with UNI EN 14511:2013


(E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C)
Mod WSB - E
Cooling capacity
Total input power
Water flow rate evaporator (7 C)
Pressure drop evaporator
E.E.R.
EEEC(1)
Power supply
Input current cooling
Maximum current (FLA)
Starting current (LRA)
Compressor
Quantity
Part load (standard expansion valve)
Part load (electronic expansion valve)
Evaporator
Quantity
Evaporator hydraulic connection
Hydraulic connection type
Sound pressure(2)

1402
1602
1802
2002
2202
2502
2802
311
365
410
465
521
594
665
82
92
107
120
131
146
159
53490 62780 70520 79924 89610 102170 114380
48
53
50
51
54
53
64
3.79
3.97
3.83
3.88
3.98
4.07
4.18
A
A
A
A
A
A
A
400V 3~ 50Hz
A
71
81
89
113
143
161
178
203
226
254
272
A
124
144
162
182
248
288
324
344
364
430
430
A
225
264
310
391
287
336
391
462
482
575
575
Type
Twin-rotor screw
n
11
1
1
1
2
2
2
2
2
2
2
%
40-100 40-100 40-100 40-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100
%
25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100
Type
Plate
n
1
1
1
1
1
1
1
1
1
1
1

3
3
3
3
3
3
3
3
3
3
3
Type
Victaulic
dB(A)
58
58
59
60
61
61
62
61
63
63
63
kW
kW
l/h
kPa
W/W

0701
155
41
26660
40
3.78
A

0801
185
46
31820
35
4.02
A

0901
207
53
35600
30
3.91
A

1101
258
66
44380
34
3.91
A

(1) EEEC EUROVENT energy efficiency class


(2) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744.

Cooling:
leaving water temperature 7 C
entering condenser water temperature 30 C
't = 5K

Evaporating unit:
leaving evaporator water temperature 7 C
refrigerant condensing temperature 45C
't = 5K

364

Heating:
leaving water temperature 45C
entering evaporator water temperature 10C
't = 5 K

Dimensions (mm)

Mod WSB ( - L)
Height (A)
Height (A) L
Width (B)
Length (C)
Weight

mm
mm
mm
mm
kg

0701
1775
1775
810
2960
1251
1379
1479

0801
1775
1775
810
2960
1301
1429
1529

0901
1775
1775
810
2960
1357
1485
1585

1101
1775
1775
810
3360
1788
1934
2045

1402
1975
2120
810
2960
2028
2256
2256

1602
1975
2120
810
2960
2097
2325
2325

1802
2005
2120
810
2960
2169
2397
2397

2002
1985
2120
810
3360
2598
2855
2855

2202
2065
2120
810
3360
3000
3257
3257

2502
2065
2120
810
3360
3095
3352
3352

2802
2065
2120
810
3360
3095
3352
3352

0701 T
2000
2120
810
2960
1479

0801 T
2000
2120
810
2960
1529

0901 T
2000
2120
810
2960
1585

1101 T
2000
2120
810
3360
2045

1402 T
2050
2120
1250
3060
2294

1602 T
2050
2120
1250
3060
2363

1802 T
2050
2120
1250
3060
2435

2002 T
2050
2120
1250
3460
2894

2202 T
2065
2120
1250
3460
3296

2502 T
2065
2120
1250
3460
3391

2802 T
2065
2120
1250
3460
3391

Cod.: SWSBUY.13 / 1502

Mod WSB ( - L)
Height (A)
Height (A) L
Width (B)
Length (C)
Weight

mm
mm
mm
mm
kg ()
kg (L)
kg (D/DE)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293730
www.aermec.com

365

WSH

Water cooled reverse cycle heat pumps with twin-rotor screw compressor
Cooling capacity 166668kW
Heating capacity 190819kW

R134a
Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

REFRIGERANT REVERSING VALVE


OPTIONAL ELECTRONIC EXPANSION VALVE WHICH ALLOWS:
- COOLING DOWN TO -6 C
- MODULATING CAPACITY CONTROL 25-100%

Characteristics
Available in 10 sizes (4 sizes single compressor and 6 sizes dual compressor)
Manufactured with refrigerant R134a
Versions for cooling only - heat pump with
refrigerant reversing valve
Partial heat recovery option
Standard Version ():
- leaving water temperature up to 55 C in
heat pump mode
Version X:
- leaving liquid temperature down to -6 C
Version L:
- low noise
High efficiency, low noise screw compressors with modulating capacity control from
40 to 100% with standard thermostatic
expansion valve. (25 to 100% with electron-

ic expansion valve option)


Compressor discharge and liquid line isolating valves
Current transformer as standard for each
compressor
Dual refrigerant circuit plate heat exchanger
optimised for R134a on dual compressor
units
Modulating capacity control microprocessor
system
Independent control for individual circuits
Electrical panel with all cables numbered
Modulating capacity control with dynamic
display of refrigeration capacity
Always Working function. In the case of
critical conditions the unit will not stop but
automatically adjusts operation

Automatic set point compensation using


analogue inputs 4-20 mA or 010 V or an
external air sensor
Auto-adaptive differential to ensure correct
compressor operating timers
PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point
DL (Demand Limit) system permits current
limiting of the unit during times of insufficient electrical power (load peaks or generator operation)
Compact dimensions
Multilingual display panel
Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision
AERWEB300-6: Web server to monitor and
are available. Refer to the technical manual.
systems with MODBUS protocol.
remote control max. 6 units in RS485 net- MULTICHILLER: Control system for multiple
PRV3: Remote control of the chiller operating
work;
parallel installed constant flow chillers providfunctions.
AERWEB300-18: Web server to monitor and
ing individual chiller on/off and control capa RIF: Power factor correction. Connected in parremote control max. 18 units in RS485 netbility.
allel to the motor allowing about 10% reducwork;
AKW: ACOUSTIC KIT: Allows further unit
tion of input current. Must be requested at time
AERWEB300-6G: Web server to monitor and
sound reduction using an optimised enclosure
of order and is available factory fitted only.
remote control max. 6 units in RS485 netmade from a high density ecological material.
AVX: Spring anti-vibration mounts.
work with integrated GPRS modem;
AERWEB300: Accessory AERWEB allows
AERWEB300-18G: Web server to monitor and
remote control of a chiller through a comremote control max. 18 units in RS485 netmon PC and an ethernet connection over a
work with integrated GPRS modem;
common browser; 4 versions available:
SAP: A series of remote buffer tanks and pumps

366

Accessory compatibility
Mod
AERWEB300
MULTICHILLER
AER485P1
RIF
PRV3

Vers.

AVX
AKW

/L
D
-

0701

161

665
665

0801

161

665
665

0901

201

665
665

1101

241

666
666

1402

(x2)
161(x2)

662
662

1602

(x2)
161(x2)

662
662

1802

(x2)
201(x2)

662
662

2002

(x2)
201-241

663
663

2202

(x2)
241(x2)

664
664

2502

(x2)
301(x2)

664
664

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Configuration Fields:
123
|
Code

4567
8
9
10
11
|
|
|
|
|
| Expansion device |
Heat recovery
|
|
|
|
Size
Model
Version

Code:
WSH
Size:
0701, 0801, 0901, 1101, 1402, 1602, 1802, 2002, 2202, 2502
Expansion device:
- Standard, minimum leaving water temperature down to +4 C
X - With electronic expansion valve that allows:
- Leaving liquid temperature down to -6 C
- Modulating capacity control (25 - 100%)
Model:
- Standard
Heat recovery:
- Without heat recovery
D - With desuperheaters (partial heat recovery)
Version:
- Standard

12
|
Condenser

13
|
|
|
Power supply

L - Low noise
Condenser:
- PED regulation
Power supply:
- 400V 3~ 50Hz with fuses
8 - 400V 3~ 50Hz with circuit breakers
2 - 230V 3~ 50Hz with fuses *
4 - 230V 3~ 50Hz with circuit breakers *
* (not available for size 2502)
5 - 500V 3~ 50Hz with fuses
9 - 500V 3~ 50Hz with circuit breakers

Attention: The standard options are shown by the symbol


Example of configuration code: WSH1602L8
This is a WSH unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at
400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by )
in the unit configurator.

367

Technical Data
Mod WSH
Cooling capacity
Total input power
Water flow rate evaporator
Pressure drop evaporator
Water flow rate condenser
Pressure drop condenser
Heating capacity
Total input power
Water flow rate condenser
Pressure drop condenser
Water flow rate evaporator
Pressure drop evaporator
E.E.R.
EEEC(1)
C.O.P.
EEEC(1)
Power supply
Input current cooling
Input current heating
Maximum current (FLA)
Starting current (LRA)
Compressor
Part load (standard expansion valve)
Part load (electronic expansion valve)
Evaporator
Quantity
Evaporator hydraulic connection
Hydraulic connection type
Condenser
Quantity
Condenser hydraulic connection
Hydraulic connection type
Sound pressure
Sound power

kW
kW
l/h
kPa
l/h
kPa
kW
kW
l/h
kPa
l/h
kPa
W/W
W/W

A
A
A
A
Type
%
%
Type
n

Type
Type
n

Type
db(A)
db(A)

0701
166
37,14
28552
23
34434
30
190
45,84
32651
26
42361
46
4,46
C
4,15
B

0801
195
42,31
33712
24
40411
31
218
52,05
37468
25
48746
46
4,62
B
4,20
B

0901
216
48,35
37324
22
45004
30
247
59,19
42286
25
54856
43
4,48
C
4,17
B

1101
269
58,78
46440
27
55754
36
312
75,13
53526
31
69480
55
4,58
B
4,15
B

65
81
124
163

73
91
144
192

80.6
101
162
229

100
130.5
182
300

40-100
25-100

40-100
25-100

40-100
25-100

40-100
25-100

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

54
86

54
86

54
86

60
92

1402
1602
359
426
79,23
92,02
61920
73616
43
47
74338
87995
57
62
438
511
104,03 123,32
74937
87426
61
67
98039 113923
82
89
4,53
4,63
B
B
4,21
4,14
B
B
400V 3~ 50Hz
135
146.5
178.5
210
248
288
287
336
Twin-rotor screw
20-100 20-100

1802
464
103,47
80152
48
96329
65
563
133,01
96346
68
126325
89
4,49
B
4,23
B

2002
524
114,87
90472
59
108273
79
647
153,87
110620
77
144907
98
4,56
B
4,20
B

2202
591
127,11
102168
65
121776
88
730
173,98
124894
85
163764
110
4,65
B
4,20
B

2502
668
146,90
115584
74
138133
101
819
190,54
139881
97
184907
122
4,55
B
4,30
A

162
221
324
391

187.5
256.5
344
462

210
291
364
482

242
320
430
575

20-100

20-100

20-100

20-100

12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

1
3

1
3

1
3

1
3

1
3

1
3

1
3

1
3

57
89

61
93

63
95

63
95

12,5-100

Plate
1
1
3
3
Victaulic
Plate
1
1
3
3
Victaulic
57
57
89
89

(1) EEEC EUROVENT energy efficiency class

Data declared in accordance with UNI EN 14511:2013

Cooling
Evaporator
leaving water temperature 7 C
entering condenser water temperature 12 C
Condenser
leaving water temperature 35 C
entering condenser water temperature 30 C

368

Heating
Evaporator
leaving water temperature 7 C
entering condenser water temperature 10 C
Condenser
leaving water temperature 45 C
entering condenser water temperature 40 C

Sound power:
Aermec determines sound power values
on the basis of measurements made in
accordance with UNI EN ISO 9614-2, as
required for Eurovent certification.
Sound pressure:
Sound pressure in free field, at 10 m distance from the external surface of the unit (in
accordance with UNI EN ISO 3744)

Dimensions (mm)

C
B

Mod WSH
Height (A)
Width (B)
Length (C)

mm
mm
mm
mm
kg ()
kg (D)

0701
1980
2120
810
2960
1391
1622

0801
1980
2120
810
2960
1443
1674

0901
1980
2120
810
2960
1506
1737

1101
2060
2120
810
3360
1946
2200

1402
2000
2120
1260
3060
2276
2542

1602
2000
2120
1260
3060
2350
2616

1802
2000
2120
1260
3060
2423
2689

2002
2000
2120
1260
3460
2872
3168

2202
2060
2120
1260
3460
3309
3605

2502
2060
2120
1260
3460
3407
3703

Cod.: SWSHUY.08 /1503

Weight (empty)

()
L

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

369

WF

Chillers,
Water/Water indoor installation
with twin-rotor screw compressor
Cooling capacity 6301549kW
Heating capacity 6761668kW

R134a

Energy
Efficiency
Classification
Eurovent

Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

OPTIMISED FOR LOW CONDENSER TEMPERATURES


for example: units working in cooling mode with ground or tower water, or units
working in heat pump mode with low leaving water temperature

MAXIMUM CONDENSER LEAVING WATER


TEMPERATURE: 50C
STANDARD ELECTRONIC EXPANSION VALVE
Characteristics
Version
WF_ Standard chillers
WF_A High efficiency version
Operational limits (1)
- condenser leaving water temperature up to
50 C
- evaporator leaving liquid temperature down
to -6 C
- Two independent refrigerant circuits
- High efficiency, low noise screw compressors
with modulating capacity control from 12,5 a
100% for each compressor)
- Shell and tube evaporator optimised for
refrigerant R134a
- Standard electronic expansion valve
- Compact dimensions
- Suitable for use in heat pump mode with
leaving water temperature up to 50 C (with
hydraulic system reversing) and with ground

water or geothermal loops. For heating mode


operation the IS accessory, condenser
isolating valves, is required
Options available:
partial heat recovery
total heat recovery
evaporating unit
low noise unit with compressor acoustical
enclosures made from galvanised steel and
high density sound absorbent material
Modulating capacity control microprocessor
system
Redundancy of the unit (one microprocessor
per circuit)
Leaving water temperature control with
modulating capacity control (12.5-100% for
each compressor) and dynamic display of the
refrigeration capacity
Condensing control based on pressure with
0-10 Vdc signal for controlling a modulating

valve / variable speed pump


- Electrical panel with all cables numbered
- Current transformer as standard for each
compressor
- Always Working function. In the case of
critical conditions the unit will not stop but
automatically adjusts operation
- Automatic set point compensation using
analogue inputs 4-20 mA or 010 V or an
external air sensor
- Auto-adaptive differential to ensure correct
compressor operating timers
- PDC (Pull Down Control) system which
prevents capacity loading when the water
temperature quickly approaches the set point
- DL (Demand Limit) system permits current
limiting of the unit during times of insufficient
electrical power (load peaks or generator
operation)
- Multilingual display panel

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervision
Accessories factory fitted only
remote control max. 6 units in RS485 netsystems with MODBUS protocol.
RIF: Power factor correction. Connected in parwork with integrated GPRS modem;
AERWEB300: Accessory AERWEB allows
allel to the motor allowing about 10% reducAERWEB300-18G: Web server to monitor and
remote control of a chiller through a comtion of input current.
remote control max. 18 units in RS485 net AKW: ACOUSTIC KIT. (only for Versions L)
mon PC and an ethernet connection over a
work with integrated GPRS modem;
Allows further unit sound reduction using an
common browser; 4 versions available:
PRV3: Remote control of the chiller operating
optimised enclosure made from a high densiAERWEB300-6: Web server to monitor and
functions.
ty ecological material.
remote control max. 6 units in RS485 net MULTICHILLER: Control system for multiple
IS: Condenser isolating valves. Mandatory
work;
parallel installed constant flow chillers proaccessory for units operating in heat pump
AERWEB300-18: Web server to monitor and
viding individual chiller on/off and control
mode. Factory fitted only.
remote control max. 18 units in RS485 netcapability.
work;
AVX: Spring anti-vibration mounts.
AERWEB300-6G: Web server to monitor and

370

Compatibility of accessories
Mod
AER485P1

Vers

2512
(x2)

2812
(x2)

3212
(x2)

3612
(x2)

4212
(x2)

4812
(x2)

5612
(x2)

6412
(x2)

AERWEB300

MULTICHILLER

PRV3

Compatibility AVX
standard / standard Low noise
Mod WF
AVX

2512
673

2812
673

3212
673

3612
674

4212
674

4812
674

5612
675

6412
675

Mod WF
AVX
High efficiency/High efficiency low noise
Mod WF
AVX

2512L
673

2812L
673

3212L
674

3612L
674

4212L
674

4812L
674

5612L
675

6412L
675

2512A
673

2812A
673

3212A
674

3612A
675

4212A
675

4812A
675

5612A
676

6412A
676

Mod WF
AVX
Accessories factory fitted only
RIF

2512AL
674

2812AL
674

3212AL
675

3612AL
675

4212AL
675

4812AL
675

5612AL
676

6412AL
676

RIFWF2512 RIFWF2812 RIFWF3212 RIFWF3612 RIFWF4212 RIFWF4812 RIFWF5612 RIFWF6412

AKW

(1)

IS1
IS2
IS3

(2)
(2)
(2)

/A

/A

(1) The accessory is only available for the low noise version "L"
(2) For heating mode operation the IS accessory, condenser isolating valves, is required

Attention: For D - T - E version - please contact us

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2
3,4,5,6
7

A
9

L
10

D
T
11

12

Code
WF
Size
2512-2812-3212-3612-4212-4812-5612-6412
Model
Optimised for low condensing temperature
Version
Standard
High efficiency
Equipment
Standard
low noise
Heat recovery
Without recovery
With Desuperheater
With total recovery (3)

Evaporator
Standard
E Evaporating unit
Power supply
400V/3/50Hz with fuses
8 400V/3/50Hz with circuit breakers
5 500V/3/50Hz with fuses (4)

9 500V/3/50Hz with circuit breakers (4)

(3) options T are not compatible with option "E"


(4) 500V/3/50Hz available only size 2512-2812

371

Technical Data
Model WF standard
Cooling capacity
Total input power
E.E.R.
Energy efciency classication
E.S.E.E.R.
Water ow rate evaporator
Total pressure drops system side
Water ow rate condenser
Total pressure drops geothermal side
Heating capacity
Total input power
COP
Energy efciency classication
Water ow rate condenser
Total pressure drops system side
Water ow rate evaporator
Total pressure drops geothermal side

Model WF_A high efficency


Cooling capacity
Total input power
E.E.R.
Energy efciency classication
E.S.E.E.R.
Water ow rate evaporator
Total pressure drops system side
Water ow rate condenser
Total pressure drops geothermal side
Heating capacity
Total input power
COP
Energy efciency classication
Water ow rate condenser
Total pressure drops system side
Water ow rate evaporator
Total pressure drops geothermal side

(1)
(1)
(1)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

(1)
(1)
(1)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

2512
630
125,06
5,04
B
6,16
108704
41
128639
16
678
158,11
4,29
B
116616
13
91126
28

2812
720
143,21
5,03
B
6,19
124356
58
147069
16
775
180,80
4,29
B
133300
13
104215
39

3212
872
174,00
5,01
B
6,16
150500
56
178115
18
940
219.28
4,29
B
161508
14
126214
38

3612
984
194,84
5,05
A
6,18
169764
47
200810
16
1060
246.23
4,31
B
182148
13
142442
32

4212
1111
219,28
5,06
A
6,19
191608
43
226576
18
1195
277.48
4,31
B
205368
14
160596
29

4812
1276
253,97
5,02
B
6,2
220332
62
260529
24
1374
319.33
4,30
B
235984
19
184676
43

5612
1406
280,17
5,02
B
6,18
242864
65
287309
17
1515
353.36
4,29
B
260408
14
203545
44

6412
1546
309,99
4,99
B
6,16
267116
75
316136
19
1668
390.48
4,27
B
286724
15
223978
51

2512A
639
120,53
5,30
A
6,63
110252
44
129043
63
676
150.92
4,50
A
116272
51
92252
30

2812A
725
137,92
5,26
A
6,61
125216
59
146621
64
772
171.87
4,49
A
132268
51
104980
40

3212A
887
168,89
5,25
A
6,63
153252
62
179396
72
944
210.18
4,49
A
161680
58
128346
42

3612A
1004
188,58
5,32
A
6,66
173204
44
202616
69
1066
237.08
4,50
A
182664
56
144919
30

4212A
1132
213,76
5,30
A
6,67
195564
62
228734
69
1199
260
4,50
A
206228
55
161508
42

4812A
1278
239,85
5,33
A
6,66
220504
42
257923
74
1358
300.67
4,52
A
232716
59
184840
29

5612A
1413
269,78
5,24
A
6,54
243724
41
285881
74
1506
338.30
4,45
A
258172
59
204250
28

6412A
1549
298,99
5,18
A
6,49
267288
51
313857
77
1654
373.85
4,43
B
283456
62
223978
35

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; Condenser water temperature (in/out) 30C/35C
(1) EUROVENT for reversible units side water certies the sun made cold (12-7 C - 30-35 C)
Heating
Condenser water temperature (in/out) 40C/45C; Evaporator water temperature (in/out) 10C/5C

Model WF_E Evaporating unit


Cooling capacity
Total input power
E.E.R.
Water ow rate evaporator
Total pressure drops system side

kW
kW
W/W
l/h
kPa

2512E
547
143
3,83
94084
31

2812E
624
162
3,85
107328
43

3212E
748
195
3,84
128656
41

3612E
842
221
3,81
144824
34

4212E
954
247
3,86
164088
31

4812E
1077
279
3,86
185244
44

5612E
1208
313
3,86
207776
47

6412E
1328
345
3,85
228416
55

Model WF_AE Evaporating unit


Cooling capacity
Total input power
E.E.R.
Water ow rate evaporator
Total pressure drops system side

kW
kW
W/W
l/h
kPa

2512A
585
143
4,09
100620
36

2812A
665
162
4,1
114380
49

3212A
800
195
4,1
137600
50

3612A
899
221
4,07
154628
35

4212A
1016
248
4,1
174752
49

4812A
1148
280
4,1
197456
34

5612A
1246
313
3,98
214312
31

6412A
1382
346
3,99
237704
40

Cooling
Evaporator water temperature (in/out) 12C/7C; Condensing temperature 45C

372

Technical Data
GENERAL DATA
Electrical data

Total input current cooling mode


Total input current heating mode

A
A
A
A
A
A

Maximum current (FLA)


Starting current (LRA)
Compressors

type
n
n
%

Compressors
Circuits
(1)
(1)

Capacity control

/A
E

2812

3212

3612

4212

4812

5612

6412

212
202
271
258
294
447

243
232
312
297
336
528

282
268
361
343
396
596

317
303
406
388
446
659

349
332
447
425
494
712

416
392
533
501
572
872

457
437
585
559
636
968

506
483
648
619
702
1156

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

35-100

35-100

35-100

35-100

35-100

35-100

35-100

35-100

type

R134a

R134a

R134a

R134a

R134a

R134a

R134a

R134a

type
n

1
6"
8"

1
6"
8"

1
6"
8"

Shell and tube


1
1
8"
8"
10"
10"

1
8"
10"

1
8"
10"

1
8"
10"

type
n

2
5"
4"

2
5"
4"

2
5"
5"

Shell and tube


2
2
5"
5"
5"
5"

2
5"
5"

2
6"
6"

2
6"
6"

61,6
93,6

62
94

61,5
93,5

63,5
95,5

65,3
97,3

65,9
97,9

Refrigerant
System side exchanger
Evaporator
Hydraulic connections (Victaulic in/out)

2512

12,5-100

Geothermal side exchanger


Condenser
Hydraulic connections (Victaulic in/out)
Sound data
Sound pressure
Sound power
Power supply

dB(A)
dB(A)
V/ph/Hz

61,7
62,6
93,7
94,6
400V/3/50Hz

(1) Electronic expansion valve


Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions and Weight

Mod WF
Height
width
depth
Weight

mm
mm
mm
Kg

(A)
(B)
(C)

2512
2100
3690
1470
3570

2812
2100
3690
1470
3650

3212
2050
4030
1470
4470

3612
2120
4030
1520
4750

4212
2140
4370
1550
5050

4812
2140
4370
1550
5180

5612
2210
4610
1600
6030

6412
2210
4760
1600
6260

Mod WF
Height
width
depth
Weight

mm
mm
mm
Kg

(A)
(B)
(C)

2512A
2180
4330
1470
4080

2812A
2180
4330
1470
4140

3212A
2190
4330
1537
5470

3612A
2340
4370
1695
5950

4212A
2340
4550
1695
6240

4812A
2340
4550
1695
6440

5612A
2380
4800
1700
7230

6412A
2380
4800
1700
7360

Attention: For D - T - E version - please contact us


Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

373

Cod.: SWFUY.07/ 1501

HWF

Chillers,
Water/Water indoor installation
with twin-rotor screw compressor
Cooling capacity 6281524kW
Heating capacity 6711615kW

Energy
Efficiency
Classification
Eurovent

Aermec
participate in the EUROVENT
program: LCP
the products are present on the site
www.eurovent-certification.com

OPTIMISED FOR HIGH CONDENSER TEMPERATURES


for example: units operating in heating mode

MAXIMUM CONDENSER LEAVING WATER


TEMPERATURE: 60C
STANDARD ELECTRONIC EXPANSION VALVE WHICH
ALLOWS
Characteristics
Version
HWF_ Standard chillers
HWF_A High efficiency version
Operational limits (1)
- condenser leaving water temperature up to
60 C
- evaporator leaving liquid temperature down
to -6 C
- Two independent refrigerant circuits
- High efficiency, low noise screw compressors
with modulating capacity control from 12,5 a
100% for each compressor)
- Shell and tube evaporator optimised for
refrigerant R134a
- Standard electronic expansion valve
- Compact dimensions
- Suitable for use in heat pump mode with
leaving water temperature up to 60 C (with
hydraulic system reversing) and with dry-

cooler. For heating mode operation the IS


accessory, condenser isolating valves, is
required
Options available:
partial heat recovery
total heat recovery
evaporating unit
low noise unit with compressor acoustical
enclosures made from galvanised steel and
high density sound absorbent material
Modulating capacity control microprocessor
system
Redundancy of the unit (one microprocessor
per circuit)
Leaving water temperature control with
modulating capacity control (12.5-100% for
each compressor) and dynamic display of the
refrigeration capacity
Condensing control based on pressure with
0-10 Vdc signal for controlling a modulating

valve / variable speed pump


- Electrical panel with all cables numbered
- Current transformer as standard for each
compressor
- Always Working function. In the case of
critical conditions the unit will not stop but
automatically adjusts operation
- Automatic set point compensation using
analogue inputs 4-20 mA or 010 V or an
external air sensor
- Auto-adaptive differential to ensure correct
compressor operating timers
- PDC (Pull Down Control) system which
prevents capacity loading when the water
temperature quickly approaches the set point
- DL (Demand Limit) system permits current
limiting of the unit during times of insufficient
electrical power (load peaks or generator
operation)
- Multilingual display panel

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervision
Accessories factory fitted only
remote control max. 6 units in RS485 net RIF: Power factor correction. Connected in parsystems with MODBUS protocol.
work with integrated GPRS modem;
allel to the motor allowing about 10% reduc AERWEB300: Accessory AERWEB allows
AERWEB300-18G: Web server to monitor and
tion of input current.
remote control of a chiller through a comremote control max. 18 units in RS485 net AKW: ACOUSTIC KIT. (only for Versions L)
mon PC and an ethernet connection over a
work with integrated GPRS modem;
Allows further unit sound reduction using an
common browser; 4 versions available:
PRV3: Remote control of the chiller operating
optimised enclosure made from a high densiAERWEB300-6: Web server to monitor and
functions.
ty ecological material.
remote control max. 6 units in RS485 net MULTICHILLER: Control system for multiple
IS: Condenser isolating valves. Mandatory
work;
parallel installed constant flow chillers proaccessory for units operating in heat pump
AERWEB300-18: Web server to monitor and
viding individual chiller on/off and control
mode. Factory fitted only.
remote control max. 18 units in RS485 netcapability.
work;
AVX: Spring anti-vibration mounts.
AERWEB300-6G: Web server to monitor and

374

Mod
AER485P1

Vers

AERWEB300

2512
(x2)

2812
(x2)

3212
(x2)

3612
(x2)

4212
(x2)

4812
(x2)

5612
(x2)

6412
(x2)

MULTICHILLER

PRV3

Compatibility AVX
standard / standard Low noise
Mod HWF
2512
673
AVX
Mod HWF
2512L
673
AVX
High efficiency/High efficiency low noise
Mod HWF
2512A
673
AVX

2812
673

3212
673

3612
674

4212
674

4812
674

5612
675

6412
675

2812L
673

3212L
674

3612L
674

4212L
674

4812L
674

5612L
675

6412L
675

2812A
673

3212A
674

3612A
675

4212A
675

4812A
675

5612A
676

6412A
676

Mod HWF
2512AL
2812AL
3212AL
3612AL
4212AL
4812AL
5612AL
6412AL
674
674
675
675
675
675
676
676
AVX
Accessories factory fitted only
RIFHWF2512 RIFHWF2812 RIFHWF3212 RIFHWF3612 RIFHWF4212 RIFHWF4812 RIFHWF5602 RIFHWF6412
RIF
AKW

(1)

IS1
IS2
IS3

(2)
(2)
(2)

/A

/A

(1) The accessory is only available for the low noise version "L"
(2) For heating mode operation the IS accessory, condenser isolating valves, is required

Attention: For D - T - E version - please contact us

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7
8

A
10

L
11

D
T
12

13

Code
HWF
Size
2512-2812-3212-3612-4212-4812-5612-6412
Model
Optimised for high condensing temperature
Version
Standard
High efficiency
Equipment
Standard
low noise
Heat recovery
Without recovery
With Desuperheater
With total recovery (3)

Evaporator
Standard
E Evaporating unit
Power supply
400V/3/50Hz with fuses
8 400V/3/50Hz with circuit breakers
5 500V/3/50Hz with fuses (4)

9 500V/3/50Hz with circuit breakers (4)

(3) options T are not compatible with option "E"


(4) 500V/3/50Hz available only size 2512-2812

375

Technical Data
Model HWF standard
Cooling capacity
Total input power
E.E.R.
Energy efciency classication
E.S.E.E.R.
Water ow rate evaporator
Total pressure drops system side
Water ow rate condenser
Total pressure drops geothermal side
Heating capacity
Total input power
COP
Energy efciency classication
Water ow rate condenser
Total pressure drops system side
Water ow rate evaporator
Total pressure drops geothermal side

Model HWF_A high efficency


Cooling capacity
Total input power
E.E.R.
Energy efciency classication
E.S.E.E.R.
Water ow rate evaporator
Total pressure drops system side
Water ow rate condenser
Total pressure drops geothermal side
Heating capacity
Total input power
COP
Energy efciency classication
Water ow rate condenser
Total pressure drops system side
Water ow rate evaporator
Total pressure drops geothermal side

(1)
(1)
(1)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

(1)
(1)
(1)

kW
kW
W/W
l/h
kPa
l/h
kPa
kW
kW
W/W
l/h
kPa
l/h
kPa

2512
628
130,1
4,83
B
5,85
108360
41
129112
16
671
151,10
4,50
A
115240
13
90893
28

2812
713
148,1
4,81
B
5,87
123152
56
146682
16
763
172
4,42
B
131064
12
103286
39

3212
843
173,6
4,85
B
5,91
145512
53
173127
17
899
202,02
4,45
A
154456
13
121939
36

3612
946
195,4
4,84
B
5,86
163228
44
194437
15
1010
227,94
4,43
B
173548
12
136783
30

4212
1092
225,0
4,85
B
5,87
188340
41
224288
17
1164
262,36
4,44
B
200036
14
157715
28

4812
1256
259,6
4,84
B
5,90
216892
60
258069
23
1339
302,02
4,44
B
230128
18
181606
41

5612
1415
294,3
4,81
B
5,86
244412
65
291144
18
1513
343,45
4,41
B
260064
14
204835
45

6412
1512
314,4
4,81
B
5,88
261268
72
311105
18
1616
366,08
4,49
B
277780
14
218956
49

2512A
643
128,7
5,00
B
6,19
110940
44
131038
65
680
148,93
4,68
A
116616
51
92923
30

2812A
730
147,1
4,96
B
6,18
126076
60
148952
66
774
169,89
4,67
A
132612
52
105651
41

3212A
855
172,1
4,96
B
6,17
147576
57
174374
68
902
193
4,56
A
155144
53
121948
39

3612A
966
193,0
5,01
B
6,18
166668
41
196897
66
1022
223,46
4,58
A
175268
51
139647
28

4212A
1108
222,3
4,98
B
6,19
191264
59
225905
67
1172
256,93
4,56
A
200896
52
160046
40

4812A
1249
249,4
5,01
B
6,19
215516
40
254569
72
1321
289,20
4,57
A
226526
56
180445
28

5612A
1435
287,4
4,99
B
6,17
247508
42
292443
77
1519
333,54
4,66
A
260236
60
207131
29

*6412A
1524
306,7
4,97
B
6,16
262988
50
310864
76
1615
355,32
4,55
A
276748
59
220212
34

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C; Condenser water temperature (in/out) 30C/35C
(1) EUROVENT for reversible units side water certies the sun made cold (12-7 C - 30-35 C)
Heating
Condenser water temperature (in/out) 40C/45C; Evaporator water temperature (in/out) 10C/5C

Model HWF_E Evaporating unit


Cooling capacity
Total input power
E.E.R.
Water ow rate evaporator
Total pressure drops system side

kW
kW
W/W
l/h
kPa

2512E
540
141
3,83
92883
30

2812E
615
161
3,82
105773
42

3212E
726
189
3,84
124872
39

3612E
816
212
3,85
140352
32

4212E
947
246
3,85
162884
31

4812E
1070
278
3,85
184040
44

5612E
1225
318
3,85
210700
49

6412E
1311
340
3,86
225492
54

Model HWF_AE Evaporating unit


Cooling capacity
Total input power
E.E.R.
Water ow rate evaporator
Total pressure drops system side

kW
kW
W/W
l/h
kPa

2512A
577
143
4,03
99244
35

2812A
657
162
4,06
113004
48

3212A
779
191
4,08
133988
47

3612A
873
214
4,08
150156
33

4212A
1012
248
4,08
174064
49

4812A
1143
280
4,08
196596
34

5612A
1263
320
3,95
217236
32

6412A
1362
342
3,98
234264
39

Cooling
Evaporator water temperature (in/out) 12C/7C; Condensing temperature 45C

376

Technical Data
GENERAL DATA
Electrical data

A
E
AE

Total input current cooling mode


Total input current heating mode
Total input current cooling mode

A
A
A
A
A
A
A
A

Maximum current (FLA)


Starting current (LRA)
Compressors

type
n
n
%

Compressors
Circuits
(1)
(1)

Capacity control

/A
E

2812

3212

3612

4212

4812

5612

6412

226
221
267
261
247
249
370
545

255
249
300
293
278
281
418
613

286
278
337
328
315
318
468
670

314
306
371
361
345
348
516
723

378
367
446
433
416
418
612
892

426
408
503
481
465
467
690
995

488
471
575
556
532
534
776
1193

530
514
625
606
579
581
846
1340

two screw two screw two screw two screw two screw two screw two screw two screw
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

12,5-100

35-100

35-100

35-100

35-100

35-100

35-100

35-100

35-100

type

R134a

R134a

R134a

R134a

R134a

R134a

R134a

R134a

type
n

1
6"
8"

1
6"
8"

1
6"
8"

Shell and tube


1
1
8"
8"
10"
10"

1
8"
10"

1
8"
10"

1
8"
10"

type
n

2
5"
4"

2
5"
4"

2
5"
5"

Shell and tube


2
2
5"
5"
5"
5"

2
5"
5"

2
6"
6"

2
6"
6"

93,6
61,6

94,0
62,0

93,5
61,5

95,5
63,5

97,3
65,3

97,9
65,9

Refrigerant
System side exchanger
Evaporator
Hydraulic connections (Victaulic in/out)

2512

12,5-100

Geothermal side exchanger


Condenser
Hydraulic connections (Victaulic in/out)
Sound data
Sound power
Sound pressure
Power supply

dB(A)
dB(A)
V/ph/Hz

93,7
94,6
61,7
62,6
400V/3/50Hz

(1) Electronic expansion valve


Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
Note: For more information, refer to the selection program or the technical documentation available on the website www.aermec.com

Dimensions and Weight

Mod HWF
Height
width
depth
Weight

mm
mm
mm
Kg

(A)
(B)
(C)

2512
2100
1470
3690
3570

2812
2100
1470
3690
3650

3212
2050
1470
4030
4470

3612
2120
1520
4030
4750

4212
2140
1550
4370
5100

4812
2140
1550
4370
5200

5612
2210
1600
4610
6110

6412
2210
1600
4760
6310

Mod HWF
Height
width
depth
Weight

mm
mm
mm
Kg

(A)
(B)
(C)

2512A
2180
1470
4330
4080

2812A
2180
1470
4330
4140

3212A
2190
1537
4330
5470

3612A
2340
1695
4370
5950

4212A
2340
1695
4550
6290

4812A
2340
1695
4550
6460

5612A
2380
1700
4800
7310

6412A
2380
1700
4800
7410

Attention: For D - T - E version - please contact us


Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

377

Cod.: SHWFUY.03 /1501

TW110

Water cooled modular chiller with centrifugal compressor

R134a

Aermec
participates in the EUROVENT
Program: LCP
The products of interest can be
found on the website
www.eurovent-certication.com

Characteristics
Cooling only version
New generation two-stage oil free centrifugal
compressor with magnetic levitation friction
free bearings
Plate heat exchangers optimised for use with
refrigerant R134a
Extremely compact: only 805 mm wide to
allow access through a standard doorway
Component layout designed to enable several
units to be positioned side by side in restricted plant rooms. Ideal when standby is
required or when cooling duty is to be
increased at a later date
High efficiency with generously sizes heat
exchanger

Extraordinary efficiency at part load (up to


active controls
30% higher IPLV when compared with Microprocessor control system
standard chillers)
LCD user interface: colour touch-screen with
Electronic expansion valve
simple and intuitive graphical menu
Acoustic enclosure: heavy gauge galvanized
Compressor features:
sheet steel with internal acoustic insulation.
Operates without oil as bearings are magnetic
levitation type. Vibration free and very quiet
Provided with inverter technology that permits capacity modulation down to 25%
Integrated controller that reduces starting current to 6 A only
5 times lighter than an equivalent screw compressor
Electronic controller for monitoring and pro-

Accessories
AER485P1TW: RS-485 interface for supervision systems with MODBUS protocol.
PTW: Remote control of chiller operating
functions.
MULTICHILLER: Control system for multiple

378

parallel installed constant flow chillers providing individual chiller on/off and control
capability. (When this accessory is present,
the AER485P1TW is factory fitted as standard).

Technical data
Mod.
Cooling capacity
Total input power
Evaporator water flow rate (7 C)
Evaporator pressure drop
Condenser water flow rate (30 C)
Condenser pressure drop
ENERGY INDEX
EER
ESEER
ELECTRICAL DATA
Power supply
Input current
Maximum current (FLA)
Starting current (LRA)
SOUND DATA
Sound pressure
Sound power
HYDRAULIC CONNECTION
Evaporator hydraulic connection (Victaulic)
Condenser hydraulic connection (Victaulic)

kW
kW
l/h
kPa
l/h
kPa

TW 110
284
58,47
49020
30
58236
43

W/W
W/W

4,86
7,05

A
A
A

400V 3~ 50Hz
88
134
6

dB(A)
dB(A)

77
49

3
3

Cooling
leaving water temperature 7C;
condenser entering water temperature
30 C;
't = 5 C;
Sound power:
Aermec determines sound power values
on the basis of measurements made in
accordance with UNI EN ISO 9614-2,
as required for Eurovent certification.
Sound pressure:
Sound pressure in free field, at 10 m
distance from the external surface of the
unit (in accordance with UNI EN ISO
3744)

Data declared in accordance with UNI EN 14511:2013

Dimensions (mm)

A
OUT
Condenser

IN
Condenser

IN
evaporator

OUT
evaporator

C
B

[mm] (A)
[mm] (B)
[mm] (C)
kg

TW 110
1727
805
1653
960

Cod.: STWUY.05 / 1503

Model
Height
Width
Depth
Weight

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

379

NXP

Multipurpose
Water/Water for indoor installation
scroll compressor plate exchanger
Cooling capacity 109501kW
Heating capacity 123560kW

R410A

DESIGNED FOR 2 AND 4-PIPE SYSTEMS


HIGH EFFICIENCY EVEN AT PART LOAD
OPTION VERSION WITH BUILT-IN HYDRONIC KIT
Characteristics
NXP is the range of multipurpose external units
power input
operating on refrigerant R410A, designed for 2 Heat exchangers optimised to benefit from
or 4-pipe systems. With just one unit simultanethe excellent heat transfer characteristics of
ous and independent requests for hot and
R410A.
chilled water can be accommodated all year High and low pressure transducers as standard
round.
The built-in hydronic module includes the main
water circuit components; it is available in varius
Version
configurations with one or two pumps with high
NXP_ Multipurpose standard
or low head both on the system side and recovery
NXP_L Multipurpose Low noise
side.
Operational limits (1)
Microprocessor controls
- Maximum leaving water temperature 55C
- Control from the leaving water temperature
Heating mode
- Automatic rotation of compressors and
2refrigerant circuits
pumps based on operating hours
High efficiency scroll compressors with low
- Programmable time-clock

- Analog Inputs Multifunction 0-10V, or


da 4-20mA
Load limiting safety control
Electrical panel with wires numbered all the main
components of security and control
Externally mounted user interface with display of
all operating parameters in 4 languages
Structure and base in hot dip galvanised sheet
steel with epoxy pain finish (RAL 9002)

(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com

Accessories
AER485P1: RS-485 interface for supervising
remote control maximum 6 units on RS485
systems with MODBUS protocol.
network with integrated GPRS modem;
AERWEB300: The AERWEB option allows
AERWEB300-18G: Web server to monitor and
remote control of a chiller through a standremote control maximum 18 units on RS485
ard PC and an ethernet connection with a
network with integrated GPRS modem.
standard browser; 4 versions available:
MULTICHILLER_NRP: Control system to
AERWEB300-6: Web server to monitor and
switch the individual multipurpose on and
remote control maximum 6 units on RS485
off, and command them, in a system in which
network;
several units are installed in parallel, always
AERWEB300-18: Web server to monitor and
ensuring a constant delivery to the exchanger.
remote control maximum 18 units on RS485 PGD1: Simplified remote panel. Allows connetwork;
trol of basic unit functions and alarm notificaAERWEB300-6G: Web server to monitor and
tion. Remote mounted up to 500 m away

380

with TWISTED PAIR SCREENED cable and


TCONN6J000..
AVX Anti-vibration mounts to be installed
under the base of the unit.
Accessories factory fitted only
DRE: Electronic soft starter which reduces
starting current.
Available only with 400V power supply.
RIF: Power factor correction. Connected in
parallel to the motor allowing about 10%
reduction of input current.

Compatibility of accessories
Mod. NXP
AER485P1
AERWEB300
MULTICHILLER_NRP
PGD1
AVX

(1)

Vers.
All
All
All
All
All

500

550

600

650

700

750

800

900

1000

1250

1400

1500

1650

All
All

501
98

551
98

601
95

651
95

701
95

751
95

801
95

901
96

1001
97

1251
97

1401
97

1401
97

1401
97

Accessories factory fitted only


DRE
RIF

(2)

(1) Contact us for the compatibility


(2) Only available for 400V/3N/50Hz power supply

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.
Field
1,2,3
4,5,6,7
8

9
2
4
10

L
11

4
5
12

M
N
O
P
13

U
V
W
Z

Code
NXP
Size
0500-0550-0600-0650-0700-0750-0800-0900-1000-1250-1400-1500-1650
Field of use:
standard thermostatic expansion valve (3)
System type
2-pipe system (cooling + DHW heating)
4-pipe system (cooling + heating)
Version
Standard
Low noise
Power supply
400V/3N/50Hz with circuit breakers
220V/3/50Hz with circuit breakers (4)
500V/3/50Hz with circuit breakers (5)
System integrated hydronic module
without pumps or buffer tank
n1 low head pump
n2 low head pumps
n1 high head pump
n2 high head pumps
Heat recovery integrated hydronic module
without pumps or buffer tank
n1 low head pump
n2 low head pumps
n1 high head pump
n2 high head pumps

(3) leaving water above +4 C


(4) Only size 05000700
(5) Only size 08001000

381

Technical Data
Mod. NXP Multipurpose for 2-pipe system
Cooling system side
Cooling capacity
kW
Total input power
kW
EER
W/W
ESEER
W/W
Water flow rate system side
l/h
Total pressure drop
kPa
Water flow rate geothermal side
l/h
Total pressure drop
kPa
Heating system side
Heating capacity
kW
Total input power
kW
COP
W/W
Water flow rate system side
l/h
Total pressure drop
kPa
Water flow rate geothermal side
l/h
Total pressure drop
kPa
Heating DHW side
Heating capacity
kW
Total input power
kW
COP
W/W
Water flow rate DHW side
l/h
Total pressure drop
kPa
Water flow rate geothermal side
l/h
Total pressure drop
kPa
Cooling with heat recovery
Cooling capacity
kW
Recovered power
kW
Total input power
kW
Water flow rate system side
l/h
Total pressure drop
kPa
Water flow rate DHW side
l/h
Total pressure drop
kPa
TER
(6)
W/W

500

550

600

650

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C;
Condenser water temperature (in/out) 30C/35C

382

750

800

900

1000

1250

1400

1500

1650

109
117
141
157
192
218
252
281
305
345
392
446
501
24
26
31
35
43
49
56
62
66
76
85
98
110
4,51
4,46
4,56
4,47
4,51
4,46
4,50
4,49
4,61
4,56
4,60
4,54
4,54
5,84
5,78
5,84
5,80
5,79
5,76
5,69
5,76
6,05
5,91
5,98
5,85
5,86
18755 20146 24376 27139 33192 37640 43434 48392 52654 59430 67539 76989 86485
19
21
21
25
27
29
20
25
19
23
26
32
34
22558 24271 29256 32655 39871 45278 52350 58310 63243 71477 81081 92547 103914
33
37
41
49
59
69
28
34
26
32
36
45
49
123
131
159
176
211
240
289
321
353
384
434
491
551
29
32
38
43
51
59
70
78
83
91
102
117
130
4,17
4,13
4,16
4,11
4,12
4,06
4,12
4,10
4,25
4,23
4,25
4,19
4,22
21013 22491 27168 30160 36076 40998 49658 55144 60599 65943 74492 84108 94416
27
31
34
41
49
57
24
29
22
26
30
38
40
27248 29109 35220 38994 46709 52918 64027 71019 78774 85679 96918 109091 122810
36
40
39
47
51
56
40
48
36
44
50
63
67
125
133
161
179
214
243
294
326
355
391
441
498
560
29
32
38
43
51
58
70
78
83
91
102
118
132
4,26
4,21
4,26
4,21
4,20
4,17
4,20
4,16
4,27
4,29
4,30
4,23
4,26
21380 22870 27647 30694 36679 41713 50401 55862 60964 67043 75574 85323 95990
21
24
24
29
31
35
25
30
22
27
31
39
42
27945 29810 36137 40009 47803 54252 65510 72483 79555 87695 98988 111399 125643
37
42
41
50
53
58
42
50
38
46
52
66
70
96
102
125
139
165
190
226
250
282
308
340
391
124
132
160
179
213
245
291
323
361
393
436
502
28,9
31,2
37,3
41,9
50,2
57,5
69,1
77,0
82,3
89,8 101,2 116,0
16568 17667 21508 23939 28503 32842 38879 43108 48668 53048 58568 67500
15
17
17
20
22
24
17
20
15
19
21
26
21183 22654 27472 30630 36518 42018 49961 55438 61889 67463 74778 86029
22
25
25
30
33
36
26
31
24
28
33
41
7,60
7,51
7,63
7,57
7,53
7,57
7,48
7,45
7,82
7,80
7,67
7,70

444
567
129,6
76593
28
97273
44
7,81

Heating mode with heat recovery


Condenser water temperature (in/out) 40C/45C;
Evaporator water temperature (in/out) 10C/7C
Cooling mode with heat recovery
heat recovery water temperature (in/out) 40C/45C;
Evaporator water temperature (out) 7C

Cooling (14511:2013)
Evaporator water temperature (in/out) 12C/7C;
Condenser water temperature (in/out) 30C/35C
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C;
Evaporator water temperature (in/out) 10C/7C

Mod. NXP Multipurpose for 4-pipe system


Cooling system side
Cooling capacity
kW
Total input power
kW
EER
W/W
ESEER
W/W
Water flow rate system side
l/h
Total pressure drop
kPa
Water flow rate geothermal side
l/h
Total pressure drop
kPa
Heating system side
Heating capacity
kW
Total input power
kW
COP
W/W
Water flow rate system side
l/h
Total pressure drop
kPa
Water flow rate geothermal side
l/h
Total pressure drop
kPa
Cooling with heat recovery
Cooling capacity
kW
Recovered power
kW
Total input power
kW
Water flow rate (cold side)
l/h
Total pressure drop (cold side)
kPa
Water flow rate (hot side)
l/h
Total pressure drop (hot side)
kPa
TER
(6)
W/W

700

500

550

600

650

700

750

800

900

1000

1250

1400

1500

1650

109
117
141
157
192
218
252
281
305
345
392
446
501
24
26
31
35
43
49
56
62
66
76
85
98
110
4,51
4,46
4,56
4,47
4,51
4,46
4,50
4,49
4,61
4,56
4,60
4,54
4,54
5,84
5,78
5,84
5,80
5,79
5,76
5,69
5,76
6,05
5,91
5,98
5,85
5,86
18755 20146 24376 27139 33192 37640 43434 48392 52654 59430 67539 76989 86485
19
21
21
25
27
29
20
25
19
23
26
32
34
22558 24271 29256 32655 39871 45278 52350 58310 63243 71477 81081 92547 103914
33
37
41
49
59
69
28
34
26
32
36
45
49
125
133
161
179
214
243
294
326
355
391
441
498
560
29
32
38
43
51
58
70
78
83
91
102
118
132
4,26
4,21
4,26
4,21
4,20
4,17
4,20
4,16
4,27
4,29
4,30
4,23
4,26
21380 22870 27647 30694 36679 41713 50401 55862 60964 67043 75574 85323 95990
21
24
24
29
31
35
25
30
22
27
31
39
42
27945 29810 36137 40009 47803 54252 65510 72483 79555 87695 98988 111399 125643
37
42
41
50
53
58
42
50
38
46
52
66
70
96
102
125
139
165
190
226
250
282
308
340
391
124
132
160
179
213
245
291
323
361
393
436
502
28,9
31,2
37,3
41,9
50,2
57,5
69,1
77,0
82,3
89,8 101,2 116,0
16568 17667 21508 23939 28503 32842 38879 43108 48668 53048 58568 67500
15
17
17
20
22
24
17
20
15
19
21
26
21183 22654 27472 30630 36518 42018 49961 55438 61889 67463 74778 86029
22
25
25
30
33
36
26
31
24
28
33
41
7,60
7,51
7,63
7,57
7,53
7,57
7,48
7,45
7,82
7,80
7,67
7,70
Heating (14511:2013)
Condenser water temperature (in/out) 40C/45C;
Evaporator water temperature (in/out) 10C/7C
Cooling mode with heat recovery
heat recovery water temperature (in/out) 40C/45C;
Evaporator water temperature (out) 7C

444
567
129,6
76593
28
97273
44
7,81

Technical Data
GENERAL DATA
Electrical data only cooling mode
Total input current
(7)
only heating mode
Total input current
(7)
only recovery mode
Total input current
(7)
Cooling heat recovery mode
Total input current
(7)
Maximum current (FLA)
(7)
Starting current (LRA)
(7)

500

550

600

650

700

750

800

900

1000

1250

1400

1500

1650

47

50

58

65

83

90

92

100

106

135

149

169

188

54

58

68

76

95

103

112

123

130

154

173

196

217

54

57

67

75

94

103

110

122

129

153

171

194

216

A
A
A

54

57

67

75

95

103

110

121

129

153

171

195

216

71

77

91

102

124

135

163

179

195

208

237

266

295

214

220

206

216

267

323

332

340

356

459

488

600

629

scroll
3
2
R410A

scroll
3
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

scroll
4
2
R410A

Compressors

type
n
n

Compressors

Circuits
Refrigerant
Exchanger side (hot/cold) 2 pipe system / side (cold) 4 pipe system
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
type
Exchanger
1
1
1
1
1
1
1
1
1
1
1
1
n
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
3"
3"
3"
3"
3"
3"
hydraulic connections
(7) (in/out)
Exchanger side (DHW) 2 pipe system / side (hot) 4 pipe system
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
type
Exchanger
1
1
1
1
1
1
1
1
1
1
1
1
n
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
3"
3"
3"
3"
3"
3"
hydraulic connections
(7) (in/out)
Exchanger side (geothermal)
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
plate
type
Exchanger
1
1
1
1
1
1
1
1
1
1
1
1
n
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
2" 1/2
3"
3"
3"
3"
3"
3"
hydraulic connections
(7) (in/out)
For more information, refer to the selection program Magellan or the technical documentation available
System integrated hydronic module
Sound data
dB(A)
46
47
47
48
50
54
56
56
56
58
58
60
(8)
Sound pressure
dB(A)
40
41
41
42
44
48
50
50
50
52
52
54
(8) L
dB(A)
78
79
79
80
82
86
88
88
88
90
90
92
(8)
Sound power
dB(A)
72
73
73
74
76
80
82
82
82
84
84
86
(8) L
V/ph/Hz 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3 400V/3
Power supply

plate
1
3"
plate
1
3"
plate
1
3"

60
54
92
86
400V/3

Sound power
Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.
Sound pressure
Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).
(7)The technical data are versions without hydronic module integrated
(8) Calculated in cooling mode
Note: For more information, refer to the selection program Magellan or the technical documentation available on the website www.aermec.com

Dimensions (mm)

Mod. NXP (without pumps)


Height

(mm)

Width
Depth

(mm)
(mm)

B
C

Mod. NXP (with pumps)


(mm)
A
Height
Width
Depth

(mm)
(mm)

B
C

Vers

500
1976
2120
1250
2600

550
1976
2120
1250
2600

600
1976
2120
1250
2600

650
1976
2120
1250
2600

700
1976
2120
1250
2600

750
1976
2120
1250
2600

800
2021
2120
1250
2600

900
2021
2120
1250
2600

1000
2021
2120
1250
2600

1250
2021
2120
1250
2600

1400
2021
2120
1250
2600

1500
2021
2120
1250
2600

1650
2021
2120
1250
2600

Vers

500
1976
2120
1250
3452

550
1976
2120
1250
3452

600
1976
2120
1250
3452

650
1976
2120
1250
3452

700
1976
2120
1250
3452

750
1976
2120
1250
3452

800
2021
2120
1250
3452

900
2021
2120
1250
3452

1000
2021
2120
1250
3750

1250
2021
2120
1250
3750

1400
2021
2120
1250
3750

1500
2021
2120
1250
3750

1650
2021
2120
1250
3750

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

383

Cod.: SNXPUY.01 /1403

SAP

Buffer tank with capacity from 75 to 3500 litres

Features
Buffer tank with pump fully assembled to be Pump motors protected by circuit breakers
al.
used together with water chillers. Hydraulic SAP 0075 and 0150 can be supplied with 5 SAP 1500, 2500 and 3500 can be supplied
connections to be site installed
different pump models with water flow rates
with 10 models of pumps with water flow
Units dimensionally compatible with Aermec
up to 18,000 l/h and pressures up to 140 kPa
rates up to 200,000 l/h and pressures up to
NBW, NRA, R, RV water chillers, but also
(maximum 2 pumps can be installed internal300 kPa (pump set configurations with standcompatible with any chiller
ly)
by pump are possible). For correct sizing of
Steel enclosure with epoxy powder coating SAP 0300, 0500, 0501, 0750 and 1000 can
the unit consult the technical manual.
for the maximum resistance to weathering
be supplied with 8 models of pumps with
Electric centrifugal pumps with stainless steel
water flow rates up to 60,000 l/h and presimpeller
sures up to 200 kPa (pump set configurations
Overpressure relief valve
with standby pump are possible). For correct
Fully insulated water circuit
sizing of the unit consult the technical manu-

Accessories
AVX: Spring anti-vibration mounts. Select the
thermostats to prevent freezing during winter.
AVX model from the compatibility table
Factory fitted only.
included in the technical manual.
VT: Anti-vibration mounts, set of four anti RX - RXV: Electric immersion heater (RX: 500
vibration mounts to be installed under the
W - RXV: 3 kW), installed and controlled by
units base.

SAP
0075
0150
0300
0500 - 0501
0750
1000
1500
2500
3500

384

Accessory compatibility
RX
RXV
VT 2

VT 8

Connection Schematic Example

PRIMARY-SECONDARY CIRCUITUBLE RING

PRIMARY CIRCUIT
chiller

system

system

chiller

Technical Data
Mod. SAP
Capacity
Expansion tank capacity
Relief valve setting
Water connections
Connection diameter

l
l
bar
(1)

Mod. SAP
Capacity
Expansion tank capacity
Relief valve setting
Water connections
Connection diameter

l
l
bar
(1)

Model Pump
1500 flange (*)
2500 flange (*)
3500 flange (*)

R
125
125
125

T
125
125
125

0075
75
8
6
F
1 1/4

0150
150
12
6
F
1 1/2

0300
300
18
6
F
2

0500
500
24
6
F
2 1/2

0501
500
24
6
F
2 1/2

0750
750
18 x 2
6
F
3

1000
1000
18 x 2
6
F
3

1500
1500
24 x 2
6

2500
2500
24 x 3
6

3500
3500
24 x 3
6

U
150
150
150

V
150
150
150

X
150
150
150

Y
150
150
150

W
200
200
200

K
200
200
200

J
200
200
200

I
200
200
200

Power supply = 3N~ 400V 50Hz.


(1) F = Female connection (Gas)
(*) PN16UNI2278

385

Technical Data
Pump motor power input
Pump
Max. input power
Max. input current

W
A

Pump
Max. input power
Max. input current

W
A

Pump combinations
SAP 0075
SAP 0150

AC
AC
EC

A
275
0,5

B
330
0,69

AE
AE
EE

AF
AF
EF

SAP 0300
SAP 0500
SAP 0501
SAP 0750
SAP 1000
SAP 1500
SAP 2500
SAP 3500

IS
IS
IS

IZ
UZ
IZ
UZ
IZ
UZ

C
614
1,1

E
895
1,6

F
1070
1,9

G
1550
2,8

H
2050
3,6

I
22000
43

J
17500
36,4

K
14500
30

L
3100
5,6

M
4100
7,2

N
1470
2,6

P
2600
4,4

Q
5200
8,8

R
4000
8,5

T
5200
11,5

U
5800
15,5

V
8000
15,5

W
11500
22,5

X
9000
22,5

Y
11000
22,5

ZE
CE
ZE
FS
PS
PS
LS
QS
QS
TS
YS
TS
YS
TS
YS

ZF
CF
ZF
FZ
PZ
PZ
LZ
QZ
QZ
TZ
YZ
TZ
YZ
TZ
YZ

AZ
AZ
EZ

BC
BC
FC

FS
FS
FS

FZ
FZ
FZ
MZ
LZ
JZ
VZ
JZ
VZ
JZ
VZ

LS
JS
VS
JS
VS
JS
VS

BE
BE
FE
CS
GS
GS
GS
NS
MS
KS
WS
KS
WS
KS
WS

BF
BF
FF
CZ
GZ
GZ
GZ
NZ
MZ
KZ
WZ
KZ
WZ
KZ
WZ

BZ
BZ
FZ
ES
HS
HS
HS
PS
NS
RS
XS
RS
XS
RS
XS

1st letter: primary circuit.


2nd letter: secondary circuit.
A, B = multi-speed water pumps.
L, M, Q = twin pump set.
S = pump and standby pump set.
Z = without pump.
The combinations shown in the table are the only possible ones.
A large number of different flow rate/pressure combinations are available. Refer to the technical manual.

386

ZC
CC
ZC
EZ
HZ
HZ
HZ
PZ
NZ
RZ
XZ
RZ
XZ
RZ
XZ

ZZ
CZ
ZZ
ZZ
ZZ
ZZ
MS
ZZ
ZZ
US
ZZ
US
ZZ
US
ZZ

Dimensions (mm)

SAP 0075 - 0150

SAP 0300 - 0500

SAP 0501 - 0750

SAP 1000 - 1500 - 2500 - 3500

A
B
C
kg

0075
1000
1000
700
120

0150
1000
1000
700
120

0300
1650
1100
1100
190

0500
1650
1100
1100
230

0501
1968
1550
1000
310

0750
1968
1550
1000
400

1000
2049
2200
1000
445

1500
2049
2200
1750
560

2500
2049
2200
2000
710

3500
2049
2200
2300
790

Cod.: SSAPUY.05 / 0702

SAP
Height
Width
Depth
Net weight (ZZ version)

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

387

WST

Water Station
Hydronic kit plug & play solution
for internal installation

FOR NXW RANGE


PACKAGED PLUG & PLAY CONTAINING THE MAIN
HYDRAULIC COMPONENTS
IDEAL FOR INDUSTRIAL APPLICATIONS WHERE
CHILLED WATER IS REQUIRED IN WINTER SEASONS
FREECOOLING OPERATION
Characteristics
Hydronic plug & play kit containing the
main hydraulic and controls components
of a hydraulic installation.
The WST units are designed to ease the
installation in systems where the production of chilled water is required all year
round, in combination with a water-water
chiller and a drycooler.
Operation
Chiller: When the external air temperature is
higher than the system return water temperature the cooling capacity is provided by the
chiller. The WST controls the drycooler by
modulating the fans on the basis of the chiller
condensing pressure.
Freecooling: When the external air temperature is then lower then WST turns off the chiller and uses the water from the drycooler to
cool the system water through the freecooling
heat exchanger.

Accessories
VT: Anti-vibration mounts.

388

Hydraulic components
Hydraulic circuit (drycooler side)
Water filter
Flow switches
Isolating valves
Mixing valve
Bypass valves
Pumps
Butterfly valves (enabling freecooling)
High efficiency plate heat exchanger (freecooling)
Water temperature sensors
Hydraulic circuit (chiller side)
Water filter
Flow switches
Isolating valves
Pumps
Water temperature sensors
NOTE
For the combination of the hydronic kit
options (drycooler / chiller side), refer to the
configurator.

Control
Microprocessor based electronic control
with Modbus communications protocol.
The WST comes standard with accesorio
aer485p1. Accessory to predict compulsorily nell'NXW, for communication between
the units.
Advanced electronic continuous monitoring
of multiple operating parameters and ambient conditions, in order to switch between
the operating modes (chiller/freecooling),
when available. This permits the reduction
of operating costs and provides higher energy efficiency.
Control of the drycooler fans in order to
manage the chiller condensing pressure
(chiller mode), or the recovered capacity
(freecooling mode).
Cold chiller starting control by modulating
the drycooler fans and the mixing valve.
Structure and base in epoxy painted hot
dipped galvanised steel.

Accessories compatibility
WST only cooling
without pump stand-by
with pump stand-by

AVX

01

02

03

04

05

06

325
325

326
327

327
327

328
329

328
329

328
329

Warning: NXW unit is required to use the attachment AER485P1

Tav. pairings WST


Chiller

WST

Dry coolers recommended (2)

NXW0500
NXW0550

WST01

WTR 824 EC 980

NXW 0600
NXW 0650

WST02

WTR 834 EC 980

NXW 0700
NXW 0750

WST03

WTR 844 EC 980

NXW 0800
NXW 0900

WST 04

WTR 854 EC 980

NXW 1000
NXW 1250

WST 05

WTR 864 EC 980

NXW 1400

WST 06

WTR 874 EC 980

The combinations are referred to the following conditions, to be verified in the case of particular conditions: refers to standard conditions
Cooling
System side
Water temperature (in/out) 12C/7C, Glycol 0%.

Dry-cooler side
Water temperature (in/out) 38C/43C; Glycol 35%.
(2) EC is compulsory adjustment on the fans of Dry cooler

Unit selection
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system
requirements.

Field
1,2,3
4,5

Description
WST
Size
01-02-03-04-05-06

6
7

Kit freecooling

F Frecooling
System water flow
Standard (constant water flow rate)

8
P1
P2
P3
P4
9
D1
D2
D3
D4

System side connected hydronic kit (3)


n 1 Low head system pump
n 2 Low head system pumps
n 1 High head system pump
n 2 High head system pumps
Drycooler side connected hydronic kit (3)
n 1 Low head system pump
n 2 Low head system pumps
n 1 High head system pump
n 2 High head system pumps

P1

P2

P3

P4

D1

ok

D2

n.d.

n.d.

ok

n.d.

ok

n.d.

ok

D3

ok

D4

n.d.

n.d.

ok

n.d.

ok

n.d.

ok

(3) For the compatibility between hydronic kits refer to the adjacent table

389

Technical data
Mod. WST Water Station
System side
Water flow rate
Useful static pressure
Useful static pressure
Power input
Power input
Dry cooler side (chiller mode)
Water flow rate
Useful static pressure
Useful static pressure
Power input
Power input
Dry cooler side (freecooling mode)
Cooling capacity
Water flow rate
Useful static pressure
Useful static pressure
Power input
Power input

01

02

03

04

05

06

(P1/P2)
(P3/P4)
(P1/P2)
(P3/P4)

l/h
kPa
kPa
kW
kW

17633
134
226
1,5
2,5

23458
133
217
2,2
3,1

29756
174
250
3,5
4,7

40627
164
235
4,0
5,4

51324
178
254
5,1
6,8

60613
119
198
4,7
6,4

(D1/D2)
(D3/D4)
(D1/D2)
(D3/D4)

l/h
kPa
kPa
kW
kW

24718
119
172
2,3
3,0

32876
126
201
3,7
4,9

41676
138
209
4,1
5,4

55673
173
250
6,0
6,7

71920
187
245
12,3
11,8

84920
178
214
12,7
13,9

(D1/D2)
(D3/D4)
(D1/D2)
(D3/D4)

kW
l/h
kPa
kPa
kW
kW

82,2
24718
71
125
2,3
3,0

108,5
32876
79
154
3,7
4,9

137,9
41676
109
180
4,1
5,4

188,0
55673
141
218
6,0
6,7

241,3
71920
144
202
12,3
11,8

283,9
84920
125
160
12,7
13,9

Cooling
System side
Water temperature (in/out) 12C/7C, Glycol 0%.

Dry-cooler side
Water temperature (in/out) 38C/43C; Glycol 35%.

Cooling in freecooling mode (100%)


System side
Water temperature (in/out) 14C/*; Water ow rate as in cooling operation; Glycol 0 %

Dry-cooler side
Water temperature (in/out) 6,7C/*; Water ow rate as in cooling operation; Glycol 35%

GENERAL DATA
Electrical data
Total input current

Maximum current (FLA)


hydraulic connections
hydraulic connections (in/out)
hydraulic connections system side
hydraulic connections (chiller)
hydraulic connections (dry cooler)

390

(P1/P2)
(P3/P4)
(D1/D2)
(D3/D4)
P1(P2) - D1(D2)
P3(P4) - D1(D2)
P1(P2) - D3(D4)
P3(P4) - D3(D4)

01

02

03

04

05

06

A
A
A
A
A
A
A
A

2,7
4,3
4,0
5,2
8,6
11,4
10,0
12,8

3,9
5,5
6,0
8,2
13,1
14,4
16,0
17,2

5,8
7,8
6,6
9,0
16,3
19,1
19,1
22,0

6,6
8,9
9,9
10,9
19,1
22,0
22,7
25,6

8,5
11,1
20,8
18,9
31,2
34,8
37,0
40,6

7,8
10,4
20,3
22,0
37,0
40,6
37,0
40,6

type

Victaulic
2" 1/2
2" 1/2
2" 1/2

Victaulic
2" 1/2
2" 1/2
2" 1/2

Victaulic
2" 1/2
2" 1/2
2" 1/2

Victaulic
2" 1/2
2" 1/2
2" 1/2

Victaulic
3"
3"
3"

Victaulic
3"
3"
3"

Operating schematics
Chiller Operation

WST (Water station)


FL EXT

AV

FI

AV

FI

AV

BV

MPDC1

Dry cooler

CV
FLH

VF1

SUD BP

BP

VMD

MPDC2
VF2
PE

SRI

Chiller
ET
MPE1

BP

SV
BP

MA

T1
From
cooling system

MPE2
MA

EV
FL

FL INP

AV

SAP (Buffer tank system)

T2
To
cooling system

Freecooling Operation
WST (Water station)
FL EXT

AV

FI

AV

FI

AV

BV

MPDC1

Dry cooler

CV
FLH

VF1

SUD BP

BP

VMD

MPDC2
VF2
PE

SRI

Chiller
ET
MPE1

BP

SV
BP

MA

T1
From
cooling system

MPE2
MA

EV
FL

FL INP

AV

SAP (Buffer tank system)

T2
To
cooling system

The images and drawings contained in this document are indicative only, for the purpose of illustrating the operation

Dimensional data (mm)

Model WST Water Station


Height
Width
Depth
Weight empty

A
B
(3)
C
without pump stand-by
with pump stand-by

mm
mm
mm
Kg
Kg

01
1835
796
1400
487
579

02
1837
796
1500
577
790

03
1835
796
2010
684
941

04
1956
796
2282
893
1140

05
2206
796
2579
1054
1320

06
2206
796
2623
1074
1350

(3) Including protrusions of the hydraulic connections


Aermec reserves the right to make all modifications deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

391

Cod.: SWSTUY.00/1401

TRA

Cooling towers with capacities from 49.53 up to 1084.88 kW

Features
Available in 17 different sizes
- TRA from 50 up to 750
silenced and Inspection window standard
- TRA from 850 up to 1100 standard
TRA from 850 up to 1100 silenced (L)
All with inspection door to a crawl Series
Entirely built of fibre-glass reinforced resin to
avoid corrosion problems with surface treatment to withstand ultraviolet rays, heat
changes and scuffing caused by bad weather
Limited to the three largest sizes (TRA 850,
950 and 1100) the bearing structure is made
of hot galvanised steel with 22mm thick fibreglass reinforced resin sandwich panels, with
support foam material inside. In this way, as

well achieving good mechanical strength the Axial high efficiency fan with several blades
sound of the water flowing is muffled. Surface Water drip pan, waterproof and water resitreatment to withstand ultraviolet rays, heat
stant made of fibreglass reinforced polyester
changes and scuffing caused by bad weather.
resin with multi layer glass material
Self-bearing structure
Personal protection grill made of AISI 304 on
Exchange pack and drip separator made of
the fan outlet
self-extinguishing PVC
P V C wa t e r d i s t r i b u t i o n p i p e s w i t h
polypropylene nozzles
Hydrometer (when there is not water flow
rate measuring device, this instrument makes
possible to have an approximate indication of
the flow rate of the water in circulation based
on the nozzle load drop)
Plastic bleed cock

Accessories*
RT: Heater element with regulating thermostat.

TRA
RT 11 (1 kW)
RT 12 (2 kW)
RT 13 (3 kW)
RT 15 (5 kW)
RT 17 (7.5 kW)

50

70

90

110

130

170

Compatibility of accessories
200
240
300
400

500

550

750

850

950

1100

N.B. = In the case of RT accessories, the number between brackets indicates the capacity of the heater element.
* = All the accessories and/or variants must in all cases be specified when the order is placed.

392

600

Technical data
Mod. TRA
Capacity
Air flow rate
Water flow rate
Pressure drops
Motor power
Motor poles
Motor poles (double polarity)
Fans
Nozzles
Sound pressure

kW
m3/h
l/h
kPa
kW
n.
n.
n.
n.
dB (A)

Mod. TRA
Capacity
Air flow rate
Water flow rate
Pressure drops
Motor power
Motor poles
Motor poles (double polarity)
Fans
Nozzles
Sound pressure
Sound pressure (silenced version)

kW
m3/h
l/h
kPa
kW
n.
n.
n.
n.
dB (A)
dB (A)

50
49,53
4500
7100
42
0,55
4
4/8
1
1
52
400
405,35
28350
58100
28
2,2
6
6/8
1
4
57

70
69,06
4500
9900
32
0,75
4
4/8
1
1
52
500
488,37
28350
70000
40
4
6
6/12
1
4
57

90
88,60
8100
12700
52
0,75
4
4/8
1
1
54

110
107,44
8100
15400
32
0,75
4
4/8
1
1
54

550
574,19
36000
82300
55
5,5
6
6/12
1
4
58

130
125,58
8100
18000
42
1,1
6
6/12
1
1
54

600
604,88
45350
86700
30
4
6
6/12
1
9
61

170
168,14
12600
24100
28
1,1
6
6/12
1
1
54

750
767,44
45350
110000
48
5,5
6
8/16
1
9
61

200
197,67
12600
28330
35
1,5
6
6/8
1
1
54

850
856,74
58000
122800
49
5,5
8
8/16
1
16
62
56

240
242,09
18100
34700
23
1,5
6
6/8
1
4
55
950
941,86
58000
135000
25
5,5
8
8/16
1
16
62
56

300
302,33
18100
43300
40
2,2
6
6/8
1
4
55
1100
1084,88
67000
155500
32
7,5
8
8/16
1
16
64
57

* = Sizes from 50 to 750 are only muted.


Power supply = 3~ 230V 50Hz; 3N~ 400V 50Hz.
Performance values refer to the following conditions:
Sound pressure measured in free field conditions at distance of 10 m
with direction factor = 2.
- air inlet temperature 23.5 C W.B.;
- water inlet temperature 35 C;
- water outlet temperature 29 C

Dimensions (mm)

Mod. TRA
Height
Width
Depth
Weight

A
B
C
kg

50
2110
800
800
75

70
2110
800
800
75

90
2595
1000
1000
85

110
2595
1000
1000
95

130
2595
1000
1000
95

170
2800
1200
1200
170

200
2800
1200
1200
170

240
2860
1400
1400
210

300
2860
1400
1400
210

400
3140
1740
1740
410

Mod. TRA
Height
Width
Depth
Weight

A
B
C
kg

500
3140
1740
1740
410

550
3380
1900
2100
500

600
3450
2100
2300
555

750
3450
2100
2300
580

850
3650
2030
2360
850

850L
3900
2030
2360
850

950
3650
2030
2360
815

950L
3900
2030
2360
815

1100
3650
2360
2360
915

1100L
3900
2360
2360
915

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

393

Cod.: STRAUY.03 / 1211

TRA 850-1100
TRA 850L-1100L

TRA 50-750

CSE-CDR-CVR-CGA-CMV
Remote condensers

CSE

CDR-CVR

CGA

Features
CSE SERIES
General features
Design has privileged modularity, each unit is made up
from standard sections, whose elements can be easily
removed.
Starting from the CSE 563 for the 500 range, from the
CSE 663 for the 630 range, there are models consisting
of two side by side units, making vertical installation
impossible.
All the other models are designed both for horizontal and
vertical installation.
To facilitate the connection of the condensers to the electrical system, the fan motors are wired in the factory
(excluding 350 diameter range) and connected to a junction box positioned on the collector side and protected
along with the latter by a lid that can be easily removed.
Construction features
They are designed for outdoor installation and therefore
manufactured with technologies and materials that guarantee resistance to atmospheric agents.
Coils with staggered copper pipes and corrugated or
mechanically expanded aluminium louvers. The coils are
fixed to the shoulders in a way to prevent pipe breakage
due to any vibrations.
Copper collectors with welded connections, closed to prevent impurities and moisture from getting into the circuits.
Latest generation axial fans to guarantee silent functioning
and high performance with IP54 protection rating: They
are designed for Y connections and different polarities
and allow continuous regulation of the speed via voltage
reduction.
Available versions:
(B) base
(S) silent
(E) Super silent.
CDR SERIES
General features
Two exchangers positioned as V
Two independent cooling circuits
Two rows of fans with diameter of 800mm
From 6 to 10 fans
Separate ventilation compartments for each fan
Construction features
They are designed for outdoor installation and therefore
manufactured with technologies and materials that guarantee resistance to atmospheric agents.

394

High efficiency louvred heat exchangers.


Latest generation axial fans to guarantee silent functioning
and high performance with IP54 protection rating: The
standard units are supplied with the fans wired onto the
junction box. Air flow separator for each individual fan.
Available versions:
(BT) base 6 poles
(ST) silent 8 poles
(ET) Super silent 12 poles
CVR SERIES
General features
Two exchangers positioned as V
Fans diameter 800 mm
From 2 to 5 fans
Separate ventilation compartments for each fan
Construction features
They are designed for outdoor installation and therefore
manufactured with technologies and materials that guarantee resistance to atmospheric agents.
High efficiency louvred heat exchangers.
Latest generation axial fans to guarantee silent functioning
and high performance with IP54 protection rating: The
standard units are supplied with the fans wired onto the
junction box. Air flow separator for each individual fan.
The extremely small dimensions allow installation in contained spaces, high output power per surface occupied.
Available versions:
(BT) base 6 poles
(ST) silent 8 poles
(ET) Super silent 12 poles
CGA SERIES
General features
V exchangers configuration
Low noise
Two rows of fans with diameter of 800mm
From 6 to 12 fans
Construction features
They are designed for outdoor installation and therefore
manufactured with technologies and materials that guarantee resistance to atmospheric agents.
High efficiency louvred heat exchangers.
Latest generation axial fans to guarantee silent functioning
and high performance with IP54 protection rating: The
standard units are supplied with the fans wired onto the

junction box. Air flow separator for each individual fan.


Available versions:
(BT) standard
(ST) silent
(ET) super silent
(CT) Electronic switch-over with brushless motor
CMV SERIES
General features
Configuration:Microchannel condensers for module
1 or 2 circuits
Two rows of fans
Construction features
Made using technologies and materials that provide
long-lasting weather resistance.
High efficiency finned pack heat exchangers, made with copper pipes and aluminium louvers. Next generation 800 mm
diameter axial fans in both AC and EC version to minimise
energy consumption. The standard units are supplied with
the fans wired onto the junction box.
Available versions:
(BTD): 6-pole with triangle connection
(BTY): 6-pole with star connection
(STD): 8-pole with triangle connection
(STY): 8-pole with star connection
(CTB): high power motorised EC fan
(CTE): low noise motorised EC fan

WRL 051 E

Z

WRL 071 E

Z

WRL 081 E

Z

WRL 101 E

Z

WRL 141 E

Z

WRL 161 E

Z

WRL 180 E

Z

WRL 200 E

Z

WRL 300 E

Z

WRL 400 E

Z

WRL 500 E

Z

Height (mm)

Width (mm)

Z

Length (mm)

Heat exchanger

WRL 041 E

Electrical voltage [V]

Type of fan

Z

Sound pressure Q=2 [dB(A)] 10m

Sound pressure Q=1 [dB(A)] 10m

WRL 031 E

^yD
^yD^
^ydz
^yd
^yD
^y^D
^yD^
^ydz
^yd
^yD
^yD^
^ydz
^yd
^yd
^y^d
^yd
^ydz
^yd
^y^d
^yd
^yd
^yd
^ydz
^yd
^yd
^yd
^yd
^ydz
^y^dz
^yd
^yd
^yd
^ydz
^y^d
^yd
^yd
^yd
^yd
^ydz
s^y^d
^yd
^yd
^yd
^yd
^yd
^y^d
s^y^dz
^yd
^yd
^yd
s^y^d
^y^dz
^yd
^yd
^yd
^yd^
^yd
^yd
^yd
s^ydz
^y^d
^yd
^yd^
^yd^
^yd
s^yd
^yd
^yd
^ydz
^y^dz
^yd
^yd^
^yd
s^yd
^yd
^y^d
sZy^dz
^yd
^yd

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

Z

No. of remote condensers


to be combined with the chiller

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

Remote condenser

refrigerant

WRL 026 E

code

number of circuits

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

121

113

66
57
57
56
66

60
57
56

62
57
56
60
65
63
70
76
65
70
65
76
70
74
70
68
74

61
76
71
66
73
68
73
71
60

73
68
77
73
71
63

62
68
66
77
70
65

76
74
73
71
77
81
75
71

77
73
63
81
82

74
66
85
77
66
81

70
66
83

34
26
25
24
34
27

25
24
37
30
25
24
28
34
31

45
34

34
45

43

37
43
38

44
40
34
42
37
42
40

48
42
37
46
42
40
31
48
38
31
36
35
46
38
33
48
44
43
41

46
50
43

48
46
41
32
50
50
48
42
34
53
46
34
50
48
38
34
51
38

37

28
27
37
30
32
28
27
40
33
28
27
31
37
34
42
48
37
42
37
48
42
46
42
40
46
41
32
47
43
37
45
40
45
43
32
51
45
40

45
43
34
51
41
34
40
38

41
36
51
47
46
44
42

53
46
42
51

44
35
53
53
51
45
37
56

37
53
51
41
37
54
41

AC

AC

AC
AC

AC

AC

AC

AC
AC

AC
AC
AC


AC
AC



AC
AC
AC



AC
AC



AC
AC
AC




AC
AC
AC


AC
AC
AC





AC
AC
AC
AC




AC
AC
AC
AC
AC



AC
AC
AC
AC



s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^

610
610
1105
1105
610
1160
610
1105
1105
1160
1160
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1105
1355
1355
2045
1105
2045
2045
2045
2045
2045
2045
1883
2045
2045

2045
2045
2045
1883
2045

2174
1883
1883

2174
3450
1883
1883
1883
2300
2300

2174
3450
1883
2300
2300
3548
2174
2300
3450
3450
3548
2300
2300
3548
2174
3450
3548
2150
2300
3548

560
560
833
833
560
560
560
833
833
560
560
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
1033
1033
833
833
833
833
833
833
833
833

833
833
778
833
833
833

833
1033
778

1033
778
1033

1033
833
778
1033

778

1033
1033

778
1033

1100

308
308
1060
1060
308
308
308
1060
1060
308
308
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1213
1213
1060
1060
1060
1060
1060
1060
1060
1060
1338
1060
1060

1060
1060
1060
1338
1060
1213

1338
1338
1213

1213
1338
1338
1338
1760
1760
1213
1060

1213
1338
1760
1760
1338

1760
1213
1213
1338
1760
1760
1338

1213
1338

1760
1338

395

NXW 0500 E

Z

NXW 0550 E

Z

NXW 0600 E

Z

NXW 0650 E

Z

NXW 0700 E

Z

396

Height (mm)

Z

Width (mm)

Length (mm)

WRL 650 E

Heat exchanger

Electrical voltage [V]

Z

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WRL 600 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Z

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^yd
^ydz
sZy^d
^y^dz
^y^dz
^yd
^yd
sZyd
^yd
^yd
^y^d
sZy^dz
^y^dz
^yd
sZyd
sZyd
^yd
sZyd
^yd
^y^d
^y^dz
^y^dz
^yd
sZyd
^yd
^yd
sZyd
^yd
^yd
^y^d
sZy^dz
^y^dz
^yd
sZyd
sZyd
^yd
sZyd
^yd
^y^d
^y^dz
^y^dz
^yd
sZyd
^yd
^yd
sZyd
^yd
^yd
^y^d
sZy^dz
^yd
^yd
^yd^
^yd
sZyd
sZyd
^y^d
^y^dz
^y^dz
^yd
sZyd
^yd
^yd
^yd
^yd
sZydz
^y^d
sZy^d
^y^dz
^y^dz
^yd^
^yd
^yd
sZyd
^yd
^yd

No. of remote condensers


to be combined with the chiller

WRL 550 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

80
75
70
68
68
80
77
71
67
80
72
68

82
80
77
71
67
82
72

88
80
73
71

80
72
68

82
80
77
71
67
82
72

88
80
73
71

80
72
68
65
80
78
71
67
80
72

82
80
71

66
82
76
73
72

82
80
73
71
70

48
44
38
36
36

46
40
36
48
40
36
37
51

46

36
50
40
37
37
56

41

38
37
48
40
36
37
51

46

36
50
40
37
37
56

41

38
37
48
40
36
33

46

36
48
40
37
37
51

37
35
50
45
41
40
37
37
50

41

38
37

51
47
42

52

43

51
43

40
54
52

42

53
43
40
40

52
44
42
41
40
51
43

40
54
52

42

53
43
40
40

52
44
42
41
40
51
43

36
52

42

51
43
40
40
54
52
42
40
38
53
48
44
43
40
40
53
52
44
42
41
40

AC
AC
AC
AC
AC




AC
AC
AC
AC





AC
AC
AC
AC






AC
AC
AC
AC





AC
AC
AC
AC






AC
AC
AC
AC




AC
AC
AC
AC





AC
AC
AC
AC
AC
AC







s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^

3548
4835
2150
5213
3450
3548
3548
2150
5213
3548
5213
3120
4835
3548
2150
2150
5213
3120
5213
5213
3548
4835
4600
2150
5213
5213
3120
3548
3548
5213
3120
4835
3548
2150
2150
5213
3120
5213
5213
3548
4835
4600
2150
5213
5213
3120
3548
3548
5213
3120
4835
3548
4600
5213
3120
2150
5213
3548
4835
3548
2150
5213
3548
3548
5213
3120
3548
3120
3548
4835
4600
5213
5213
3120
3548
3548

1033
1100

2066

1100

1100
2066

1100
1100

1100

2066

1100

1100

1100
2066

1100
1100

1100

2066

1100

1100

1100
2066

1100
1100

2066

1100

1100

1100

2066

1100

1338
1213

1338
1213
1338
1338

1338
1338
1338

1213
1338

1338

1338
1338
1338
1213
1760

1338
1338

1338
1338
1338

1213
1338

1338

1338
1338
1338
1213
1760

1338
1338

1338
1338
1338

1213
1338
1760
1338

1338
1338
1213
1338

1338
1338
1338
1338

1338

1338
1213
1760
1338
1338

1338
1338

NXW 1000 E

Z

NXW 1250 E

Z

NXW 1400 E

Z

Height (mm)

Z

Width (mm)

Length (mm)

NXW 0900 E

Heat exchanger

Electrical voltage [V]

Z

Type of fan

Sound pressure Q=2 [dB(A)] 10m

NXW 0800 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Z

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^yd
sZyd
^y^d
^y^dz
sZy^dz
^yd
^yd
sZyd
^yd
sZyd
^yd
^yd
sZy^d
^y^dz
sZy^dz
sZyd
^yd
sZyd
^yd
^yd
sZyd
^y^d
sZy^dz
^yd
sZyd
^yd
^yd
sZyd
sZyd
sZyd
sZyd
^ydz
^y^d
sZy^dz
^yd
sZyd
^yd
^yd
sZyd
sZyd
sZyd
Zyd
^yd
sZyd
^ydz
sZy^d
Zy^dz
^y^dz
sZyd
sZyd
^yd
^yd
sZyd
sZyd
sZyd
Dsyd
Zyd
^yd
sZyd
sZy^d
^y^dz
sZyd
^yd
sZyd
^yd
^yd
sZyd
sZyd
sZyd
Zyd
'yd^
Dsyd

No. of remote condensers


to be combined with the chiller

NXW 0750 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

82
82
73
71
70
82
80

72
70
68
83
73
71
70
82
80
74
71
68
83
75
71
83
80
74
72
71
68
66
83

75
71
85
83
76
74
72
71

68
85
84

75
72
75
85
83
82
76
74
73
71
72
68
85
84
75
75
86
85
83
82
80
76
75
73
70

66

50
50
41

38
51

47
40

36
51
42

38
51
48
43

36
51
43

51

42
40

37
35
51
47
43

53
52
44
42
41
40
37
36
53
52
47
43
40
43
54
51
50
44
42
41
40
40
36
53
52
43
43
55
53
51
50
48
44
43
41

37
34

53
53
44
42
41
54
52
50
43
42

54
45
42
41
54
51
46
42

54
46
42
54
52
45
43
42
40
38
54
50
46
42
56
55
47
45
44
43
40

56
55
50
46
43
46
57
54
53
47
45
44
43
43

56
55
46
46
58
56
54
53
51
47
46
44
42
40
37

AC
AC
AC
AC
AC






AC
AC
AC
AC





AC
AC
AC







AC
AC
AC
AC








AC
AC
AC
AC
AC
AC









AC
AC
AC
AC












s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
D
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
D

5213
3120
3548
5213
5060
5213
5213
3120
3548

5213
3548

5213
5060
3120
3548

5213
5213

5213
6030
3548

5213
5213
6030
6030
7000

5213
5213
6030
3548

5213
5213
6030
7000
7000
5060
5213
5060
5213
6030

5060
5213
5213
6030
7000
7000
4640
5060
5213
5060
6030

5060
5213
5060
5213
5213
6030
7000
7000
5060
5730

1100

1100

1100

1100

1100

1100
1100

1100

1100

1100

1100

1100
1100
1100
1100

1100

1100

1100
1100
1100
2160

1100

1100
2160
2431
1100
1100

1100
1100
1100
2255
2160

1100
1100
2431
1100

1100

1100
1100
1100
2160
2448
2255

1338

1338
1338

1338
1338

1338

1338
1338

1338

1338

1338
1338

1338

1338

1338
1338

1338
1338

1338

1338
1338

2150
1338

1338

2150
1760

1338
1338

2000
2150
1338

1760

1338

1338
1338

2150
2410
2000

397

WSA 1101 E

WSA 1402 E

WSA 1602 E

WSA 1802 E

398

Height (mm)

Width (mm)

Length (mm)

WSA 0901 E

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WSA 0801 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^d
^^d
sZ^dz
^^dz
^d
^d
^d
^d
sZd
^d
^d
sZd
sZd
^dz
^^d
sZ^dz
^d
sZd
^d
sZd
^d
^d
sZ^d
^^dz
sZd
^d^
^d
sZd
sZd
^d
sZd
sZd
sZd
^dz
^^d
sZ^dz
^d
sZd
^d
^d
sZd
sZd
sZd
^d
sZd
sZdz
Z^d
^^dz
^d
sZd
^d
^d
sZd
sZd
sZd
Zd
'd^
Dsd
Dsd
sZd
sZdz
^^dz
^d
sZd
sZd
Zd
Zd
'd^
Dsd
^d
sZd
^^dz
sZd
^d^
sZd
Zd
Zd
Zd
'd^
'd^
Dsd

No. of remote condensers


to be combined with the chiller

WSA 0701 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

346

82
73

72
84
88
80

73
72
70

82
78
73
70
82
80
74
72
68
83
73
71
84
84
82
80
74
71
68
66
83

75
71
85
83
76
74
72
71

85
84

76
75
87
84
83
82
76
75
73
70
70

65
85
80
77
85
83
76
74
73
70
67

85
77
87
87
84
83
78
76
74
70
66

50
41
37
41
53
56

47
41
40
38
37
50
46
41
38
51

42
41
36
51
42

53
52
50

43

37
35
51
47
43

53
52
44
42
41
40
37
53
52
48
44
43
55
53
52
50
44
43
41

38
37
33
53

45
53
52
45
42
41
38
35
58
54
45
56
55
53
51
46
44
42
38
34

53
44
40
44
56

52
50
44
43
41
40
53

44
41
54
52
45
44

54
45
42
56
55
53
52
46
42
40
38
54
50
46
42
56
55
47
45
44
43
40
56
55
51
47
46
58
56
55
53
47
46
44
42
41
40
36
56
52
48
56
55
48
45
44
41
38
61
57
48

58
56
54

47
45
41
37

AC
AC
AC
AC








AC
AC
AC
AC





AC
AC
AC








AC
AC
AC
AC







AC
AC
AC
AC
AC











AC
AC
AC







AC
AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
D
D
^
^
^
^
^
^
^
^
^
D
^
^
^
^
^
^
^
^
^
^
^
D

5213
3548

5213
4600
5213
5213
3120
3548
3548

3120
3548
3548
5060
5213
3120
3548

5213
3548

5213
3120

3548

5213
6030
7000

5213
5213
6030
3548

5213
5213
6030
7000
7000
5213
5060
6030

5213
5060
5213
5213
6030
7000
7000
5060
7140

6030
7000

5213
6030
7000
5060
5060
7140

7000

6030

7000

5060
5060
7140
8550
11600

1100

1100

1100
1100

1100

1100

1100

1100

1100

1100
1100

1100
1100
1100

1100

1100

1100
1100
1100

1100
1100
2160
2431

1100

1100
1100
1100
2160
2448
2255
2255
1100
1100
2431

1100
1100
2160
2160
2448
2255
2431
1100
2431
1100
2431
1100
2160
2160
2160
2448
2448
2255

1338
1338

1760
1338
1760
1338
1338

1338
1338

1338
1338

1338

1338

1338
1338

1338

1760
1338

1338

1338
1338

1338

1338
1338

1338

2150
1760
1338

1338
1338

2150
2410
2000
2000

1760
1338

2150
2150
2410
2000
1760

1760

1760

2150
2150
2150
2410
2410
2000

WSA 2802 E

WSB 0701 E

WSB 0801 E

Height (mm)

Width (mm)

Length (mm)

WSA 2502 E

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WSA 2202 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^d
^dz
Zdz
Ds^d
'^dz
sZd
Zd
^d^
Zd
Dsd
'd^
Dsd
Dsd
^dz
Ds^d
'^dz
^d^
^d^
'd^
Dsd
'd^
'd^
Dsd
Dsd
^d
^dz
'^dz
^d
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd
^d
'd^
'd^
'd^
Dsd
Dsd
^d
^d
sZdz
^^d
sZ^d
sZ^dz
^^dz
^d
^d^
^d
sZd
^d
^d
sZd
sZd
^d
^^d
^^d
sZ^dz
^d
^d
^d
sZd
^d
sZd
^d
sZd
^d

No. of remote condensers


to be combined with the chiller

WSA 2202 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

714

87
82
78
77
88
86
84
78
75
74
70
68
87
78
78
86
84
80

77
74
73
68

87
78

87
86
83
80
78
75
71

88
78

87
83
81
78
73
82
82
76
73
72

82
82
73
71
70

66
82
73
75
70
84
82
80

74
72
72
70
68

58
55
50
46
45
56
54
52
46
43
42
38
36
55
46
46
54
52
48
47
45
42
41
36

55
46
62
55
54
51
48
46
43

56
46
62
62
60
55
51

46
41
50
50
45
41
40
37
37
51
50
41

38
37
37
35
50
41
43
38
53
51

47
42
41
40

36

61
58
53

48

57
55

46
45
41

58

57
55
51
50
48
45
44

62
58

65
58
57
54
51

46
42
62

65
65
63
58
54
52

44
53
53
48
44
43
40
40
54
53
44
42
41
40
40
38
53
44
46
41
56
54
52
50
45
44
43
42

AC
AC
AC
AC
AC








AC
AC
AC








AC
AC
AC








AC
AC
AC








AC
AC
AC
AC
AC
AC
AC








AC
AC
AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

D
D

5060

5730
7000

5060

8550

11600

7140

7140

7140
8550

11600

7140

5060

7140
7140
8550

11600

8550

5730

7140
7140
8550

11600
5213
5213
3120
3548
3120

3548
5213
4600
5213
3120
3548
3548

5213
3548
4835
5060
5213
5213
5213
3120
3548

3548

5213

2431
2431
2160
2255
2448
1100
2160
2431
2160
2255
2448
2255
2255
2431
2255
2448
2431
2431
2448
2255
2448
2448
2255
2255
2431
2431
2448
2431
2160
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2448
2431
2448
2448
2448
2255
2255

1100

1100
1100

1100

1100
1100

2066
1100

1100

1100

1100

1760
1760
2150
2000
2410

2150
1760
2150
2000
2410
2000
2000
1760
2000
2410
1760
1760
2410
2000
2410
2410
2000
2000
1760
1760
2410
1760
2150
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2410
1760
2410
2410
2410
2000
2000
1338
1338

1338

1338
1338
1760
1338

1338
1338

1338
1338
1213

1338
1338
1338

1338

1338

1338

399

WSB 1602 E

WSB 1802 E

WSB 2202 E

WSB 2202 E

400

Height (mm)

Width (mm)

Length (mm)

WSB 1402 E

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WSB 1101 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^d
sZdz
^^dz
^^dz
sZd
^d
sZd
sZd
^d
^d
sZd
^^d
sZ^dz
^d
sZd
^d
^d
sZd
sZd
sZd
^d
sZd
sZ^d
sZd
^d
sZd
^d
sZd
sZd
sZd
Zd
'd^
Dsd
Dsd
^d
sZ^d
^^dz
^d
^d
sZd
sZd
Zd
Zd
'd^
Dsd
sZd
^dz
^^dz
sZd
sZd
sZd
Zd
Zd
'd^
Dsd
^d
sZd
Zdz
Ds^d
Ds^dz
^d
sZd
^d^
Zd
'd^
Dsd
'd^
Dsd
^d
^dz
Ds^d
'^dz
^d
^d^
Zd
^d^
'd^
Dsd
'd^
Dsd
Dsd

No. of remote condensers


to be combined with the chiller

WSB 0901 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

346

83
78
71
74
82
80
78
72
71
68
83
75
71
85
82
76
74
72
71

85
84
75
86
85
83
82
76
75
73
70

66
65
85
75
77
87
83
82
76
74
73
70
65
85
86
77
87
86
83
76
74
70
67

85
82
78
74

86
82
78
77
75
70
66

87
78
78

86
84
82
80
77
74
73
71

51
46

42
51
48
47
41

36
51
43

53
50
44
42
41

37
53
52
43
55
53
51
50
44
43
41

37
34
33
53
44
45
55
52
50
45
42
41
38
33
54
54
45
56
54
51
44
42
38
35
58
54
50
46
42
61
54
50
46
45
43
38
34
58
55
46
46
61
54
52
50
48
45
42
41

54

42
45
54
51
50
44
42

54
46
42
56
53
47
45
44
42
40
56
55
46
58
56
54
53
47
46
44
42
40
37
36
56
47
48
58
55
53
48
45
44
41
36
57
57
48

57
54
47
45
41
38
61
57
53

45
64
57
53

48
46
41
37
61
58

64
57
55
53
51
48
45
44
42

AC
AC
AC
AC






AC
AC
AC







AC
AC
AC











AC
AC
AC








AC
AC
AC







AC
AC
AC
AC
AC








AC
AC
AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

3548

5213

3120
3548

5213
5213

5213
6030
3548

5213
5213
6030
6030
7000
5213
5060
6030
5060
5213
5060
5213
6030
7000
7000
5060
5730

5213
7000

5213
5213
6030
7000
5060
5060
7140

7000

6030
7000
7000
5060
5060
8550

7000
5060

7000

5060
7140

8550
11600

7140

5060

7140

8550

11600

1100

1100

1100
1100

1100

1100

1100

1100
1100
1100

1100
1100
1100

1100

1100
1100
1100
2160
2448
2255
2255

1100
2431

1100
1100
2160
2160
2448
2255
1100
2431
2431
1100
1100
1100
2160
2160
2448
2255
2431
1100
2160
2255
2255
2431
1100
2431
2160
2448
2255
2448
2255
2431
2431
2255
2448
2431
2431
2160
2431
2448
2255
2448
2255
2255

1338

1338
1760

1338

1338
1338

1338

1338

1338
1338

1338

1338

1338

2150
2410
2000
2000
1338

1760
1338
1338

2150
2150
2410
2000

1760
1760

2150
2150
2410
2000
1760

2150
2000
2000
1760

1760
2150
2410
2000
2410
2000
1760
1760
2000
2410
1760
1760
2150
1760
2410
2000
2410
2000
2000

WF 2812 E

WF 3212 E

WF 3612 E

WF 4212 E

Height (mm)

Width (mm)

Length (mm)

Heat exchanger

WF 2512 E

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

Sound pressure Q=1 [dB(A)] 10m

WSB 2802 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^d
^dz
'^dz
^d
'd
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd^
'd^
'd^
Dsd
Dsd
Dsd
Dsd
Dsd
^dz
Dsdz
'^dz
^d^
Zd
^d^
'd^
Dsd
'd^
Dsd
Dsd
^d
Dsd
'dz
Zd
^d^
Dsd
'd^
'd^
Dsd
Dsd
Dsd
'd
'dz
Dsdz
'd
'd^
'd^
Dsd
'd^
Dsd
'd
'dz
Ds^d
'd
'd^
'd^
Dsd
'd^
'd^
Dsd
'd
'dz
'd^
Dsd
sZd
^d^
^d^
Zd
'd^
'd^
Dsd

No. of remote condensers


to be combined with the chiller

WSB 2502 E

refrigerant

code

number of circuits

Combinations

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
1
1
1
1
2
2
2
2
2
2
2

810

717

714

810

1126

600

87
78

87
86
83
80
78
75
71

88
78

85
83
81
76
76
75

65
87
82
78
88
86
84
80

78
75
71

88
87

88
85
83
81
76
73
75

88
84

87
86
80
84
77

80

86

74
70
66

85
88
87
84
82
77
74
68

55
46
62
62
55
54
51
48
46
43

56
46
60
53
51

44
44
43
37
33
55
50
46
56
54
52
48
47
46
43

56
55
57
56
53
51

44
41
43
60
56
52
61
55
54
48
52
45
60
57
48
61
58
54
47
42
38
34
61
57
58
53
56
55
52
50
45
42
36

62
58

65
65
58
57
54
51

46
42
62

63
56
54
52
47
47
46
40
36
58
53

57
55
51
50

46
42
62

58
60

56
54
52
47
44
46
63

55
64
58
57
51
55
48
63
60
51
64
61
57
50
45
41
37
64
60
61
56

58
55
53
48
45

AC
AC
AC









AC
AC
AC









AC
AC
AC








AC
AC
AC








AC
AC
AC






AC
AC
AC







AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D
D
D
D

D
D

D
D
D

7140

5730
5060

7140
7140
8550

11600

8550

7140
7140
8550

11600
11600

7140

5060

7140

8550

11600

5730
5060

7140
8550

11600
11600
7140
7140

7140
7140
8550

8550
11600
7140
8550
11600
7140
8550
8550
11600
7140
8550
11600
8550
8550
8550
11600
7000

5060
7140
8550
11600

2431
2431
2448
2431
2448
2160
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2448
2448
2448
2255
2255
2255
2255
2255
2431
2255
2448
2431
2160
2431
2448
2255
2448
2255
2255
2431
2255
2448
2160
2431
2255
2448
2448
2255
2255
2255
2448
2448
2255
2448
2448
2448
2255
2448
2255
2448
2448
2255
2448
2448
2448
2255
2448
2448
2255
2448
2448
2448
2255
1100
2431
2431
2160
2448
2448
2255

1760
1760
2410
1760
2410
2150
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2410
2410
2410
2000
2000
2000
2000
2000
1760
2000
2410
1760
2150
1760
2410
2000
2410
2000
2000
1760
2000
2410
2150
1760
2000
2410
2410
2000
2000
2000
2410
2410
2000
2410
2410
2410
2000
2410
2000
2410
2410
2000
2410
2410
2410
2000
2410
2410
2000
2410
2410
2410
2000

1760
1760
2150
2410
2410
2000

401

WF 2512 AE

WF 2812 AE

WF 3212 AE

WF 3612 AE

WF 4212 AE

402

Height (mm)

Width (mm)

Length (mm)

WF 6412 E

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WF 5612 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

'd
Dsd
'd
Dsd
Zd
'd
Dsd
'd
'd
Dsd
Dsd
^dz
'^dz
'd^
Dsd
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd^
'd^
'd^
Dsd
Dsd
^d
^dz
'^dz
^d
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd^
'd^
'd^
Dsd
Dsd
'dz
Ds^d
'd
'd^
'd^
'd^
Dsd
'd
Dsd
Ds^d
'd
'd
'd^
'd^
Dsd
Zd
Dsd
'd^
'd^
Dsd
'd
Dsd
'd
Dsd
Zd
'd
'd
Dsd
Dsd

No. of remote condensers


to be combined with the chiller

WF 4812 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
1
1
1
1
2
2
2
2
2

736

1126

1126

1301

648

86
84
83
81
78
77
72
87
78
83

81
76
73

88
78

87
83
81
78
73

87
78

87
86
83
80
78
75
71

88
78

87
83
81
78
73
88
80

88
84
77

80

88
81
76
75
74
70
66

87
84
81
78
74
72

61
58
64
57
54
52
51

46
45
40
55
46
51
60

44
41

56
46
62
55
51

46
41

55
46
62
55
54
51
48
46
43

56
46
60
55
51

46
41
56
48
63
57
56
52
45
60
57
48
63
62
58
56

44
43
42
38
34
61
58
62
55
52

46
42
40

64
61
67
60
57
55
54
52

48
43
58

54
63
52
47
44
62

65
58
54
52

44
62
58

65
58
57
54
51

46
42
62

63
58
54
52

44

51
66
60

55
48
63
60
51
66
65
61

52
47
46
45
41
37
64
61
65
58
55
52

45
43

AC
AC









AC
AC





AC
AC
AC






AC
AC
AC








AC
AC
AC






AC
AC





AC
AC
AC










AC
AC








s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

D
D

D
D

D
D

D
D

8550
11600
8550
11600
5060
7140

7140
8550

11600

8550
7140
11600
8550

11600

8550

7140
7140
8550

11600

7140

5060

7140
7140
8550

11600

8550

7140
7140
8550

11600
7140
11600
7140
7140
8550
8550
11600
7140

11600
7140
8550
8550
8550
11600
5060

7140
8550
11600
8550
11600
8550
11600
5060
7140
8550

11600

2448
2255
2448
2255
2160
2448
2255
2448
2448
2255
2255
2431
2448
2448
2255
2448
2255
2255
2431
2255
2448
2431
2448
2448
2448
2255
2255
2431
2431
2448
2431
2160
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2448
2448
2448
2255
2255
2448
2255
2448
2448
2448
2448
2255
2448
2255
2255
2448
2448
2448
2448
2255
2160
2255
2448
2448
2255
2448
2255
2448
2255
2160
2448
2448
2255
2255

2410
2000
2410
2000
2150
2410
2000
2410
2410
2000
2000
1760
2410
2410
2000
2410
2000
2000
1760
2000
2410
1760
2410
2410
2410
2000
2000
1760
1760
2410
1760
2150
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2410
2410
2410
2000
2000
2410
2000
2410
2410
2410
2410
2000
2410
2000
2000
2410
2410
2410
2410
2000
2150
2000
2410
2410
2000
2410
2000
2410
2000
2150
2410
2410
2000
2000

HWF 2512 E

HWF 2812 E

HWF 3212 E

HWF 3612 E

Height (mm)

Width (mm)

Length (mm)

WF 6412 AE

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

WF 5612 AE

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

^d
Zd
Dsdz
Dsd
^d
Zd
^d^
'd^
Dsd
'd^
Dsd
Dsd
^d
Dsd
'dz
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
'dz
Ds^d
^d
'd^
'd^
'd^
Dsd
Dsd
^dz
Dsdz
'^dz
^d^
Zd
^d^
'd^
Dsd
'd^
Dsd
'd^
Dsd
^d
Dsd
'dz
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
'd
'dz
Dsdz
'd^
'd^
'd^
Dsd
Dsd
'd
'dz
Ds^d
'd^
'd^
'd^
Dsd
Zd
Zd
'd^
Dsd
Dsd

No. of remote condensers


to be combined with the chiller

WF 4812 AE

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2

717
1452

714

717

714

1126

87
82

87
86
83

78
75
71

88
87

88
85
83
81
76
73

88

87
85
84
78
76
87
82
78
88
86
84
80

78
75
74
71

88
87

88
85
83
81
76
73

88
84

87
84
80
76

80

88
86

78
74
70
67
66

55
50
58
60
55
54
51
47
46
43

56
55
57
56
53
51

44
41

56
47
62
55
53
52
46
44
55
50
46
56
54
52
48
47
46
43
42

56
55
57
56
53
51

44
41
60
56
52
57
55
52
48
44
60
57
48
57
56
54
47
46
42
38
35
34

62
58
53
61
63
58
57
54
50

46
42
62

58
60

56
54
52
47
44
62

50
65
58
56
55

47
58
53

57
55
51
50

46
45
42
62

58
60

56
54
52
47
44
63

55
60
58
55
51
47
63
60
51
60

57
50

45
41
38
37

AC
AC
AC









AC
AC
AC







AC
AC
AC






AC
AC
AC









AC
AC
AC







AC
AC
AC





AC
AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

D
D

D
D

D
D

D
D

5060

11600

5060

7140

8550

11600

5730
5060

7140
7140
8550

11600

7140

7140
7140
8550

11600

7140

5060

7140

8550

8550
11600

5730
5060

7140
7140
8550

11600
7140
7140

7140
7140
8550

11600
7140
8550
11600
7140
8550
8550
11600
5060
5060
8550

11600

2431
2160
2255
2255
2431
2160
2431
2448
2255
2448
2255
2255
2431
2255
2448
2160
2431
2448
2448
2448
2255
2255
2431
2448
2255
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2160
2431
2448
2255
2448
2255
2448
2255
2431
2255
2448
2160
2431
2448
2448
2448
2255
2255
2448
2448
2255
2448
2448
2448
2255
2255
2448
2448
2255
2448
2448
2448
2255
2160
2160
2448
2255
2255

1760
2150
2000
2000
1760
2150
1760
2410
2000
2410
2000
2000
1760
2000
2410
2150
1760
2410
2410
2410
2000
2000
1760
2410
2000
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2150
1760
2410
2000
2410
2000
2410
2000
1760
2000
2410
2150
1760
2410
2410
2410
2000
2000
2410
2410
2000
2410
2410
2410
2000
2000
2410
2410
2000
2410
2410
2410
2000
2150
2150
2410
2000
2000

403

HWF 6412 E

HWF 2512 AE

HWF 2812 AE

HWF 3212 AE

404

Height (mm)

Width (mm)

Length (mm)

HWF 5612 E

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

HWF 4812 E

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

'dz
Dsdz
'd
'd^
Dsd
^d^
Zd
'd^
'd^
Dsd
^dz
Ds^d
'^dz
'd
Dsd
^d^
Zd
^d^
'd^
Dsd
'd^
Dsd
'd^
Dsd
'd^
Dsd
^d
Dsd
'dz
Dsd
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd^
'd^
'd^
Dsd
Dsd
^d
^dz
'^dz
^d
Zd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
Dsd
'^dz
^d
'd^
'd^
'd^
Dsd
Dsd
'd
'dz
Ds^d
'd
'd^
'd^
'd^
Dsd
Dsd
'd^
Dsd
Dsd

No. of remote condensers


to be combined with the chiller

HWF 4212 E

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

1
1
1
1
1
2
2
2
2
2
2
2
2
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2

600

714

1126

85

85
84
82
77
74
68
87
78
78

88
86
84
80

77
75
77
75
74
71

88
87

88
85
83
81
76
73

88
78

87
83
81
78
73

87
78

87
86
83
80
78
75
71

88
78

85
83
81
78
73

88
80

87
86
84
77
71
70
67
66

57
53
64
58
53
52
50
45
42
36
55
46
46
64
57
56
54
52
48
47
45
43
45
43
42

56
55
60
57
56
53
51

44
41

56
46
60
55
51

46
41

55
46
60
55
54
51
48
46
43

56
46
60
53
51

46
41
60
56
48
63
55
54
52
45

38
35
34

60
56
67
61
56
55
53
48
45

58

67
60

57
55
51
50
48
46
48
46
45
42
62

58
63
60

56
54
52
47
44
62

63
58
54
52

44
62
58

63
58
57
54
51

46
42
62

63
56
54
52

44
63

51
66
58
57
55
48
42
41
38
37

AC
AC








AC
AC
AC













AC
AC
AC








AC
AC
AC






AC
AC
AC








AC
AC
AC






AC
AC
AC










s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

D
D

D
D

D
D

8550
11600
8550
8550
11600

5060
7140
8550
11600

7140
8550
11600

5060

7140

7140

7140

8550
11600

5730
11600
5060

7140
7140
8550

11600

8550

7140
7140
8550

11600

7140

5060

7140
7140
8550

11600

8550

7140
7140
8550

11600
7140
7140
11600
7140
7140
8550
8550
11600

7140

11600

2448
2255
2448
2448
2255
2431
2160
2448
2448
2255
2431
2255
2448
2448
2255
2431
2160
2431
2448
2255
2448
2255
2448
2255
2448
2255
2431
2255
2448
2255
2160
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2448
2448
2448
2255
2255
2431
2431
2448
2431
2160
2431
2448
2448
2448
2255
2255
2431
2255
2448
2431
2448
2448
2448
2255
2255
2448
2448
2255
2448
2448
2448
2448
2255
2255
2448
2255
2255

2410
2000
2410
2410
2000
1760
2150
2410
2410
2000
1760
2000
2410
2410
2000
1760
2150
1760
2410
2000
2410
2000
2410
2000
2410
2000
1760
2000
2410
2000
2150
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2410
2410
2410
2000
2000
1760
1760
2410
1760
2150
1760
2410
2410
2410
2000
2000
1760
2000
2410
1760
2410
2410
2410
2000
2000
2410
2410
2000
2410
2410
2410
2410
2000
2000
2410
2000
2000

HWF 5612 AE

HWF 6412 AE

1
1
1
1
1
1
1
2
2
2
2
2
1
1
1
1
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

1126

1301

717
1452

714

80

86

78
76
74
70
66

87
84
81
78
74
72

87
82

86
83

78
75
71

88
78

88
85
83
81
76
73

88

87
85
84
78
76

60
57
48
63
58
54
47
46
44
42
38
34
61
58
62
55
52

46
42
40

55
50
58
54
51
47
46
43

56
46
60
56
53
51

44
41

56
47
62
55
53
52
46
44

63
60
51
66
61
57
50

47
45
41
37
64
61
65
58
55
52

45
43
62
58
53
61
57
54
50

46
42
62

63

56
54
52
47
44
62

50
65
58
56
55

47

AC
AC
AC









AC
AC







AC
AC
AC







AC
AC
AC







AC
AC
AC







s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

D
D

D
D

D
D

D
D

D
D

7140

11600
7140
8550
8550
11600
5060
5060
7140
8550
11600
8550
11600
8550
11600
5060
7140
8550
8550
11600

5060

11600

7140

8550

11600

8550
11600

7140
7140
8550

11600

7140

7140
7140
8550

11600

2448
2255
2255
2448
2448
2448
2255
2160
2160
2448
2448
2255
2448
2255
2448
2255
2160
2448
2448
2448
2255
2431
2160
2255
2255
2431
2448
2255
2448
2255
2255
2431
2255
2448
2255
2431
2448
2448
2448
2255
2255
2431
2448
2255
2431
2448
2448
2448
2255
2255

2410
2000
2000
2410
2410
2410
2000
2150
2150
2410
2410
2000
2410
2000
2410
2000
2150
2410
2410
2410
2000
1760
2150
2000
2000
1760
2410
2000
2410
2000
2000
1760
2000
2410
2000
1760
2410
2410
2410
2000
2000
1760
2410
2000
1760
2410
2410
2410
2000
2000

Code: SCONREUY.04 / 1506

Height (mm)

Width (mm)

Length (mm)

HWF 4812 AE

Heat exchanger

Electrical voltage [V]

Type of fan

Sound pressure Q=2 [dB(A)] 10m

HWF 4212 AE

Sound pressure Q=1 [dB(A)] 10m

Sound power [dB(A)]

Dissipated heating capacity


External air temp. 30C,
Average condensation temp. 45C

'd
Dsd
Ds^d
'd
'd^
'd^
Dsd
Zd
Zd
'd^
'd^
Dsd
'd
Dsd
'd
Dsd
Zd
'd
'd
'd
Dsd
^d
Zd
Dsdz
Dsd
^d^
'd^
Dsd
'd^
Dsd
Dsd
^d
Dsd
'^dz
Dsd
^d^
'd^
'd^
'd^
Dsd
Dsd
^d
'dz
Ds^d
^d
'd^
'd^
'd^
Dsd
Dsd

No. of remote condensers


to be combined with the chiller

HWF 3612 AE

Remote condenser

dissipated heating capacity


Water temp. 7C-12C,
Condensation temp. 45C

refrigerant

number of circuits

code

Combinations

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

405

WTE - WTR - WDR - WTS - WTA


Dry coolers

WTE

WTR-WDR

WTS

WTA

Features
WTE RANGE
General features
Design has privileged modularity, each unit is
made up from standard sections, whose elements
can be easily removed
Parting from the WTE 563 for the 500 range,
from the WTE 663 for the 630 range, models are
found that are made up from two flanked units,
thus making vertical installation impossible.
All of the other models are designed for both horizontal and vertical installation. The support feet
supplied can be used in both cases.
To ease the connection of the electric system chillers, the fan motors are wired in the factory (excluding 350 diameter range) and connected to a junction box positioned on the collectors side and
protected along with the latter by a lid that can be
easily removed.
Construction features
They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric
agents
Coils with staggered copper pipes and corrugated
or mechanically expanded aluminium louvers. The
coils are fixed to the shoulders in a way to prevent
pipe breakage due to any vibrations.
Iron collectors with GAS threading.
Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: They are envisioned for D/Y connections and different polarities and allow continuous
regulation of the speed via voltage reduction.
Available versions:
(B) basic
(S) silent
(E) Super silent.
WTA RANGE
General features
Two exchangers positioned as W
Two independent cooling circuits
Two rows of fans with diameter of 800mm
From 4 to 16 fans
Separate ventilation compartments for each fan

406

Construction features
They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric
agents
High efficiency louvred heat exchangers
Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with
the fans wired onto the junction box. Air flow
separator for each individual fan.
Available versions:
(BT) basic 6-pole
(ST) silent 8-pole
(ET) Super silent 12-pole
WTR RANGE
General features
V exchangers configuration
Two independent cooling circuits
Low noise
Two rows of fans with diameter of 800mm
From 4 to 10 fans
Construction features
They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric
agents
High efficiency louvred heat exchangers
Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with
the fans wired onto the junction box. Air flow
separator for each individual fan.
Available versions:
(BT) basic 6-pole
(ST) silent 8-pole
(ET) Super silent 12-pole
WTS RANGE
General features
Two exchangers positioned as V
Fans diameter 500 mm
From 2 to 5 fans
Separate ventilation compartments for each fan

Construction features
They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric
agents
High efficiency louvred heat exchangers
Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating. The standard units are supplied with
fans wired on junction box. Air flow separator for
each individual fan. The extremely small dimensions allow installation in contained spaces, high
output power per surface occupied
Available versions:
(BT) basic 4-pole
(ST) silent 6-pole
(ET) Super silent 8-pole
WTR RANGE
General features
Two exchangers positioned as V
Fans diameter 800 mm
From 2 to 5 fans
Separate ventilation compartments for each fan
Construction features
They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric
agents
High efficiency louvred heat exchangers
Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with
the fans wired onto the junction box. Air flow
separator for each individual fan. The extremely
small dimensions allow installation in contained
spaces, high output power per surface occupied
Available versions:
(BT) basic 6-pole
(ST) silent 8-pole
(ET) Super silent 12-pole

Choosing the unit


Field configuration:
123
|
Code

4
|
|
|
Fluido

5
|
[dm] fans

67
|
|
n fans

8
|
n rows

Code:
WTS-WTE-WTR-WTA-WDR
Fluido:
- Acqua o acqua glicolata con PS max 6 bar
[dm] fans:
3 - 350
5 - 500
6 - 630
8 - 800
9 - 910
N fans:
* - up 1 to 16
N rows:
* - up 1to 6

9
|
|
motor
Type

10
|
Power supply

11
|
|
Electrical
connection

Motor type:
B - Standard
S - Silenced
E - Extra silenced
Power suppluy:
T - 400V/3/50Hz
M - 230V/1/ 50Hz
Electrical connection:
D - Triangle
- mono-phase

Technical and dimensional data


WTE

Model WTE

wiring connec.

WTE0312BM
WTE 0313BM
WTE0314BM
WTE0322BM
WTE0323BM
WTE0324BM
WTE0332BM
WTE0333BM
WTE0334BM
WTE0342BM
WTE0343BM
WTE0344BM
WTE0362BM
WTE0363BM
WTE0364BM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

Fans
[dm]
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

WTE0312SM
WTE0313SM
WTE0314SM
WTE0322SM
WTE0323SM
WTE0324SM
WTE0332SM
WTE0333SM
WTE0334SM
WTE0342SM
WTE0343SM
WTE0344SM
WTE0362SM
WTE0363SM
WTE0364SM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Fan
[n]
1
1
1
2
2
2
3
3
3
4
4
4
6
6
6

Rows
[n]
2
3
4
3
3
4
2
3
4
2
3
4
2
3
4

1
1
1
2
2
2
3
3
3
4
4
4
6
6
6

2
3
4
3
3
4
2
3
4
2
3
4
2
3
4

air ow rate Power


[m3/h]
[kW]
2.500
4,6
2.200
6
2400
7,4
5000
9,2
4400
12
4800
15
7500
14
6600
18
7200
22
10000
18
8800
24
9600
30
15000
28
13200
38
14400
47

WTE0513 BT
triangle
5
1
3
WTE0514 BT
triangle
5
1
4
WTE0515 BT
triangle
5
1
5
WTE0522 BT
triangle
5
2
2
WTE0523 BT
triangle
5
2
3
WTE0524 BT
triangle
5
2
4
The performance refers to the following conditions:
e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
36
36
36
39
39
39
41
41
41
42
42
42
44
44
44

A
820
820
820
820
820
820
820
820
820
820
820
820
820
820
820

Dimensions [mm]
B
620
620
620
620
620
620
620
620
620
1200
1200
1200
1200
1200
1200

C
760
760
760
1310
1310
1310
1860
1860
1860
1310
1310
1310
1860
1860
1860

1500
1300
1400
3000
2600
2800
4500
3900
4200
6000
5200
5600
9000
7800
8400

3,6
4,4
5
7,4
9
10
11
14
16
15
18
20
24
28
32

26
26
26
29
29
29
31
31
31
32
32
32
34
34
34

820
820
820
820
820
820
820
820
820
820
820
820
820
820
820

620
620
620
620
620
620
620
620
620
1200
1200
1200
1200
1200
1200

760
760
760
1310
1310
1310
1860
1860
1860
1310
1310
1310
1860
1860
1860

7750
7400
7100
16000
15500
14800
-

17
20
23
26
35
42
Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

48
48
48
51
51
51

1060
1060
1060
1060
1060
1060

833
833
833
833
833
833

1105
1105
1105
2045
2045
2045

407

Technical and dimensional data


WTE

Model WTE

wiring connec.

WTE0525BT
WTE0533BT
WTE0534BT
WTE0535BT
WTE0543BT
WTE0544BT
WTE0545BT
WTE0563BT
WTE0564BT
WTE0565BT
WTE0583BT
WTE0584BT
WTE0585BT
WTE0513ST
WTE0514ST
WTE0515ST
WTE0522ST
WTE0523ST
WTE0524ST
WTE0525ST
WTE0533ST
WTE0534ST
WTE0535ST
WTE0543ST
WTE0544ST
WTE0545ST
WTE0563ST
WTE0564ST
WTE0565ST
WTE0583ST
WTE0584ST
WTE0585ST
WTE0513ET
WTE0514ET
WTE0515ET
WTE0522ET
WTE0523ET
WTE0524ET
WTE0525ET
WTE0533ET
WTE0534ET
WTE0535ET
WTE0543ET
WTE0544ET
WTE0545ET
WTE0563ET
WTE0564ET
WTE0565ET
WTE0583ET
WTE0584ET
WTE0585ET

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

WTE0513BM
WTE0514BM
WTE0515BM
WTE0522BM
WTE0523BM
WTE0524BM
WTE0525BM
WTE0533BM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

5
5
5
5
5
5
5
5

Fan
[n]
2
3
3
3
4
4
4
6
6
6
8
8
8
1
1
1
2
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8
1
1
1
2
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8

Rows
[n]
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
2
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
2
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

1
1
1
5
2
2
2
3

3
4
5
5
3
4
5
3

air ow rate Power


[m3/h]
[kW]
14200
47
23250
54
22200
63
21300
70
31000
71
29600
83
28400
96
46500
108
44400
126
42600
140
62000
142
59200
166
56800
192
5100
13
4850
11
4600
17
10650
21
10200
27
9700
32
9200
34
15300
41
14550
48
13800
52
20400
56
19400
64
18400
69
30600
82
29100
96
27600
104
40800
112
38800
129
36800
139
3350
10
3200
11
3000
12
7300
17
6700
21
6400
24
6000
25
10050
31
9600
36
9000
38
13400
42
12800
48
12000
50
20100
63
19200
72
18000
75
26800
84
25600
97
24000
100

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

408

7360
7030
6745
15200
14720
14060
13490
22080

Sound pressure
dB(A)
51
53
53
53
54
54
54
56
56
56
57
57
57
38
38
38
41
41
41
41
43
43
43
44
44
44
46
46
46
47
47
47
32
32
32
35
35
35
35
37
37
37
38
38
38
40
40
40
41
41
41

A
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060

Dimensions [mm]
B
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833

C
2045
2985
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925
1105
1105
1105
2045
2045
2045
2045
2985
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925
1105
1105
1105
2045
2045
2045
2045
2985
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925

45
45
45
48
48
48
48
50

1060
1060
1060
1060
1060
1060
1060
1060

833
833
833
833
833
833
833
833

1105
1105
1105
2045
2045
2045
2045
2985

16
20
22
26
34
41
45
52

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

Technical and dimensional data


Model WTE

wiring connec.

WTE0534BM
WTE0535BM
WTE0543BM
WTE0544BM
WTE0545BM
WTE0563BM
WTE0564BM
WTE0565BM
WTE0583BM
WTE0584BM
WTE0585BM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

Fans
[dm]
5
5
5
5
5
5
5
5
5
5
5

Fan
[n]
3
3
4
4
4
6
6
6
8
8
8

Rows
[n]
4
5
3
4
5
3
4
5
3
4
5

air ow rate Power


[m3/h]
[kW]
21090
61
20235
67
29440
69
28120
80
26980
92
44160
104
42180
122
40470
135
58880
137
56240
160
53960
185

WTE0513SM
WTE0514SM
WTE0515SM
WTE0522SM
WTE0523SM
WTE0524SM
WTE0525SM
WTE0533SM
WTE0534SM
WTE0535SM
WTE0543SM
WTE0544SM
WTE0545SM
WTE0563SM
WTE0564SM
WTE0565SM
WTE0583SM
WTE0584SM
WTE0585SM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

1
1
1
2
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8

3
4
5
2
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

5000
4750
4510
10440
10000
9500
9020
15000
14250
15350
20000
19000
18040
30000
28500
27060
40000
38000
36080

13
15
17
21
27
31
34
40
47
51
55
65
68
80
95
102
111
127
136

35
35
35
38
38
38
38
40
40
40
41
41
41
43
43
43
44
44
44

1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060

833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833

1105
1105
1105
2045
2045
2045
2045
2985
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925

WTE0513 EM
WTE0514 EM
WTE0515 EM
WTE0522 EM
WTE0523 EM
WTE0524 EM
WTE0525 EM
WTE0533 EM
WTE0534 EM
WTE0535 EM
WTE0543 EM
WTE0544 EM
WTE0545 EM
WTE0563 EM
WTE0564 EM
WTE0565 EM
WTE0583 EM
WTE0584 EM
WTE0585 EM

Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase
Monophase

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

1
1
1
2
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8

3
4
5
2
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

3720
3550
3330
8100
7440
7100
6660
11160
10650
9990
14880
14200
13320
22320
21300
19980
29760
28400
26640

11
12
13
18
22
25
27
34
38
41
45
51
55
68
76
82
90
102
109

32
32
32
35
35
35
35
37
37
37
38
38
38
40
40
10
41
41
41

1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060

833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833
833

1105
1105
1105
2045
2045
2045
2045
2985
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925

WTE0613BT
WTE0614BT
WTE0615BT
WTE0623BT
WTE0624BT
WTE0625BT
WTE0633BT
WTE0634BT
WTE0635BT
WTE0643BT
WTE0644BT
WTE0645BT
WTE0663BT
WTE0664BT
WTE0665BT
WTE0683BT
WTE0684BT
WTE0685BT

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

1
1
1
2
5
2
3
3
3
4
4
4
6
6
6
8
8
8

3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

9550
9150
8700
19100
18300
17400
28650
27450
26100
38200
36600
34800
57300
54900
52200
76400
73200
69600

23
28
31
48
56
62
74
85
93
98
113
123
147
171
186
195
226
246

49
49
49
52
52
52
54
54
54
55
55
55
57
57
57
58
58
58

1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200

1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033

1340
1340
1340
2500
2500
2500
3660
3660
3660
4820
4820
4820
3660
3660
3660
4820
4820
4820

WTE0613ST
WTE0614ST
WTE0615ST

triangle
triangle
triangle

6
6
6

1
1
1

3
4
5

6750
6500
6200

19
22
24

42
42
42

1200
1200
1200

1033
1033
1033

1340
1340
1340

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
50
50
51
51
51
53
53
53
54
54
54

A
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060
1060

Dimensions [mm]
B
833
833
833
833
833
833
833
833
833
833
833

C
2985
2985
3925
3925
3925
2985
2985
2985
3925
3925
3925

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

409

Technical and dimensional data


WTE

Model WTE

wiring connec.

WTE0623ST
WTE0624ST
WTE0625ST
WTE0633ST
WTE0634ST
WTE0635ST
WTE0643ST
WTE0644ST
WTE0645ST
WTE0663ST
WTE0664ST
WTE0665ST
WTE0683ST
WTE0684ST
WTE0685ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Fan
[n]
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8

Rows
[n]
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

air ow rate Power


[m3/h]
[kW]
13500
38
13000
45
12400
48
20250
58
19500
67
18600
73
27000
77
26000
88
24800
98
40500
116
39000
134
37200
147
54000
154
52000
177
49600
196

WTE0613ET
WTE0614ET
WTE0615ET
WTE0623ET
WTE0624ET
WTE0625ET
WTE0633ET
WTE0634ET
WTE0635ET
WTE0643ET
WTE0644ET
WTE0645ET
WTE0663ET
WTE0664ET
WTE0665ET
WTE0683ET
WTE0684ET
WTE0685ET

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

1
1
1
2
2
2
3
3
3
4
4
4
6
6
6
8
8
8

3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5

4450
4300
4050
8900
8600
8100
13350
12900
12150
17800
17200
16200
26700
25800
24300
35600
34400
32400

14
16
17
29
33
35
44
50
53
59
67
69
89
100
105
118
133
139

32
32
32
35
35
35
37
37
37
38
38
38
40
40
40
41
41
41

1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200

1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033

1340
1340
1340
2500
2500
2500
3660
3660
3660
4820
4820
4820
3660
3660
3660
4820
4820
4820

WTE0913BT
WTE0914BT
WTE0916BT
WTE0923BT
WTE0924BT
WTE0926BT
WTE0933BT
WTE0934BT
WTE0936BT
WTE0943BT
WTE0944BT
WTE0946BT
WTE0963BT
WTE0964BT
WTE0966BT

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9

1
1
1
2
2
2
3
3
3
4
4
4
6
6
6

3
4
6
3
4
6
3
4
6
3
4
6
3
4
6

20400
19350
17700
40800
38700
35400
61200
58050
53100
81600
77400
70800
122400
116100
106200

47
55
65
96
111
133
144
168
195
191
223
267
289
335
390

56
56
56
59
59
59
61
61
61
62
62
62
64
64
64

1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530

1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434

1633
1633
1633
3063
3063
3063
4493
4493
4493
3063
3063
3063
4493
4493
4493

WTE0913ST
WTE0914ST
WTE0916ST
WTE0923ST
WTE0924ST
WTE0926ST
WTE0933ST
WTE0934ST
WTE0936ST
WTE0943ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

9
9
9
9
9
9
9
9
9
9

1
1
1
2
2
2
3
3
3
4

3
4
6
3
4
6
3
4
6
3

15000
14050
12900
30000
28100
25800
45000
42150
38700
60000

39
45
51
78
91
104
118
133
158
156

50
50
50
53
53
53
55
55
55
56

1530
1530
1530
1530
1530
1530
1530
1530
1530
1530

1434
1434
1434
1434
1434
1434
1434
1434
1434
1434

1633
1633
1633
3063
3063
3063
4493
4493
4493
3063

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

410

Sound pressure
dB(A)
45
45
45
47
47
47
48
48
48
50
50
50
51
51
51

A
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200

Dimensions [mm]
B
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033
1033

C
2500
2500
2500
3660
3660
3660
4820
4820
4820
3660
3660
3660
4820
4820
4820

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

Technical and dimensional data


Model WTE

wiring connec.

WTE0944ST
WTE0946ST
WTE0963ST
WTE0964ST
WTE0966ST

triangle
triangle
triangle
triangle
triangle

Fans
[dm]
9
9
9
9
9

WTE0913ET
WTE0914ET
WTE0916ET
WTE0923ET
WTE0924ET
WTE0926ET
WTE0933ET
WTE0934ET
WTE0936ET
WTE0943ET
WTE0944ET
WTE0946ET
WTE0963ET
WTE0964ET
WTE0966ET

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9

Fan
[n]
4
4
6
6
6

Rows
[n]
4
6
3
4
6

1
1
1
2
2
2
3
3
3
4
4
4
6
6
6

3
4
6
3
4
6
3
4
6
3
4
6
3
4
6

air ow rate Power


[m3/h]
[kW]
56200
183
51600
208
90000
235
84300
267
77400
316
9200
8600
7800
18400
17200
15600
27600
25800
23400
36800
34400
31200
55200
51600
46800

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
56
56
58
58
58

A
1530
1530
1530
1530
1530

Dimensions [mm]
B
1434
1434
1434
1434
1434

C
3063
3063
4493
4493
4493

38
38
38
41
41
41
43
43
43
44
44
44
46
46
46

1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530
1530

1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434
1434

1633
1633
1633
3063
3063
3063
4493
4493
4493
3063
3063
3063
4493
4493
4493

28
32
35
57
65
70
87
96
106
115
129
141
174
193
212
Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

WTS

Model WTS

wiring connec.

WTS0523BT
WTS0524BT
WTS0533BT
WTS0534BT
WTS0543BT
WTS0544BT
WTS0553BT
WTS0554BT

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
5
5
5
5
5
5
5
5

Fan
[n]
2
2
3
3
4
4
5
5

Rows
[n]
3
4
3
4
3
4
3
4

air ow rate Power


[m3/h]
[kW]
15.800
46
15.200
51
23700
69
22800
77
31600
92
30400
103
39500
115
38000
128

WTS0523ST
WTS0524ST
WTS0533ST
WTS0534ST
WTS0543ST
WTS0544ST
WTS0553ST
WTS0554ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

5
5
5
5
5
5
5
5

2
2
3
3
4
4
5
5

3
4
3
4
3
4
3
4

10400
10000
15600
15000
20800
20000
26000
25000

38
41
57
62
76
82
95
103

41
41
43
43
44
44
45
45

1065
1065
1065
1065
1065
1065
1065
1065

780
780
780
780
780
780
780
780

1610
1610
2265
2265
2920
2920
3575
3575

WTS0523ET
WTS0524ET
WTS0533ET
WTS0534ET
WTS0543ET
WTS0544ET
WTS0553ET
WTS0554ET

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

5
5
5
5
5
5
5
5

2
2
3
3
4
4
5
5

3
4
3
4
3
4
3
4

6800
6500
10200
9750
13600
13000
17000
16250

27
29
41
44
54
58
66
71

34
34
36
36
37
37
38
38

1065
1065
1065
1065
1065
1065
1065
1065

780
780
780
780
780
780
780
780

1610
1610
2265
2265
2920
2920
3575
3575

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
51
51
53
53
54
54
55
55

A
1065
1065
1065
1065
1065
1065
1065
1065

Dimensions [mm]
B
780
780
780
780
780
780
780
780

C
1610
1610
2265
2265
2920
2920
3575
3575

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

411

Technical and dimensional data


WTR

Model WTR

wiring connec.

WTR0823BT
WTR0824BT
WTR0833BT
WTR0834BT
WTR0843BT
WTR0844BT
WTR0853BT
WTR0854BT

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
8
8
8
8
8
8
8
8

Fan
[n]
2
2
3
3
4
4
5
5

Rows
[n]
3
4
3
4
3
4
3
4

air ow rate Power


[m3/h]
[kW]
46.000
131
45.000
150
70000
204
66000
229
92000
275
88500
307
114000
338
112000
390

WTR0823ST
WTR0824ST
WTR0833ST
WTR0834ST
WTR0843ST
WTR0844ST
WTR0853ST
WTR0854ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

8
8
8
8
8
8
8
8

2
2
3
3
4
4
5
5

3
4
3
4
3
4
3
4

34000
32000
50500
48000
67000
63000
83500
80000

112
122
167
183
223
240
279
298

43
43
45
45
46
46
47
47

1590
1590
1590
1590
1590
1590
1590
1590

1100
1100
1100
1100
1100
1100
1100
1100

2270
2270
3210
3210
4180
4180
5150
5150

WTR0823ET
WTR0833ET
WTR0843ET
WTR0853ET

triangle
triangle
triangle
triangle

8
8
8
8

2
3
4
5

3
3
3
3

21100
31750
42300
52900

79
121
162
203

33
35
36
37

1590
1590
1590
1590

1100
1100
1100
1100

2270
3210
4180
5150

Sound pressure
dB(A)
54
54
56
56
57
57
58
58
59
59
59
59
60
60

A
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090

Dimensions [mm]
B
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200

C
3250
3250
3850
3850
5100
5100
8100
8100
8700
8700
9950
9950
11200
11200

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
51
51
53
53
54
54
55
55

A
1590
1590
1590
1590
1590
1590
1590
1590

Dimensions [mm]
B
1100
1100
1100
1100
1100
1100
1100
1100

C
2270
2270
3210
3210
4180
4180
5150
5150

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

WTA

Model WTA
WTA0843BT
WTA0844BT
WTA0863BT
WTA0864BT
WTA0883BT
WTA0884BT
WTA08103BT
WTA08104BT
WTA08123BT
WTA08124BT
WTA08143BT
WTA08144BT
WTA08163BT
WTA08164BT

wiring connec.
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Fan
[n]
4
4
6
6
8
8
10
10
12
12
14
14
16
16

Rows
[n]
3
4
3
4
3
4
3
4
3
4
3
4
3
4

air ow rate Power


[m3/h]
[kW]
84.000
283
82.000
314
122000
391
112000
422
165000
525
153000
569
205000
674
190000
736
242000
782
222000
844
282000
916
258000
991
324000
1050
296000
1138

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

412

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

Technical and dimensional data


Model WTA

wiring connec.

WTA0843ST
WTA0844ST
WTA0863ST
WTA0864ST
WTA0883ST
WTA0884ST
WTA08103ST
WTA08104ST
WTA08123ST
WTA08124ST
WTA08143ST
WTA08144ST
WTA08163ST
WTA08164ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
8
8
8
8
8
8
8
8
8
8
8
8
8
8

WTA0843 ET
WTA0863 ET
WTA0883 ET
WTA08103 ET
WTA08123 ET
WTA08143 ET
WTA08163 ET

triangle
triangle
triangle
triangle
triangle
triangle
triangle

8
8
8
8
8
8
8

Fan
[n]
4
4
6
6
8
8
10
10
12
12
14
14
16
16

Rows
[n]
3
4
3
4
3
4
3
4
3
4
3
4
3
4

4
6
8
10
12
14
16

6
3
3
3
3
3
3

air ow rate Power


[m3/h]
[kW]
62000
220
60000
236
87000
297
82000
316
116000
398
110000
424
147000
517
142000
551
170000
593
162000
632
202000
694
187000
739
230000
796
215000
847
37400
52500
70300
89900
105100
122800
140600

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Sound pressure
dB(A)
46
46
48
48
49
49
50
50
51
51
51
51
52
52

A
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090
2090

Dimensions [mm]
B
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200

C
3250
3250
3850
3850
5100
5100
8100
8100
8700
8700
9950
9950
11200
11200

36
38
39
40
41
41
42

2090
2090
2090
2090
2090
2090
2090

2200
2200
2200
2200
2200
2200
2200

3250
3850
5100
8100
8700
9950
11200

Sound pressure
dB(A)
54
54
56
56
57
57
58
58

A
2150
2150
2150
2150
2150
2150
2150
2150

Dimensions [mm]
B
1850
1850
1850
1850
1850
1850
1850
1850

C
2270
2270
3240
3240
4210
4210
5180
5180

159
218
292
377
436
510
584
Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

Model WDR

wiring connec.

WDR0843BT
WDR0844BT
WDR0863BT
WDR0864BT
WDR0883BT
WDR0884BT
WDR08103BT
WDR08104BT

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

Fans
[dm]
8
8
8
8
8
8
8
8

Fan
[n]
4
4
6
6
8
8
10
10

Rows
[n]
3
4
3
4
3
4
3
4

air ow rate Power


[m3/h]
[kW]
77.100
232
70.400
254
115700
349
105500
381
154200
467
140700
508
192800
583
176000
635

WDR0843ST
WDR0844ST
WDR0863ST
WDR0864ST
WDR0883ST
WDR0884ST
WDR08103ST
WDR08104ST

triangle
triangle
triangle
triangle
triangle
triangle
triangle
triangle

8
8
8
8
8
8
8
8

4
4
6
6
8
8
10
10

3
4
3
4
3
4
3
4

55000
50000
82000
74500
110000
99000
136000
125000

188
203
286
301
384
405
476
507

46
46
48
48
49
49
50
50

2150
2150
2150
2150
2150
2150
2150
2150

1850
1850
1850
1850
1850
1850
1850
1850

2270
2270
3240
3240
4210
4210
5180
5180

WDR0843ET
WDR0863ET
WDR0883ET
WDR08103ET

triangle
triangle
triangle
triangle

8
8
8
8

4
6
8
10

3
3
3
3

33350
49900
66600
83250

137
206
274
343

36
38
39
40

2150
2150
2150
2150

1850
1850
1850
1850

2270
3240
4210
5180

The performance refers to the following conditions:


e Sound pressure measured in free field at a distance of 10m and
directionality factor = 2;

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Ta = 25C
Twi = 40 C
Two = 35 C
Glyvol = 34%

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

413

Cod.: SDRYCOOLERUI.02 / 1201

WDR

DMP

Recessed dehumidifier
for floor systems

R134a

White:
front panel: RAL 9010

Features

Main features:
vertical installation recessed in the wall;
silenced functioning;
small electric consumption;
high dehumidification efficiency.

Components:
DMP 20: Monobloc dehumidifier unit, recessed inside the formwork.
- electrostatically pre-charged air filter;
- condensate drip tray;
- hermetic compressor assembled on rubber
The DMP dehumidifiers can be integrated peranti-vibration mounts;
fectly in residential and tertiary environments - condensing and evaporating coils realised in
with:
copper pipes and aluminium louvers;
- floor systems;
- pre-cooling coil: to improve the dehumidifica-

tion efficiency of the unit;


- post-cooling coil: to control the temperature
of the outlet air and send thermally neutral air
to the room;
- centrifugal flow fan with uneven pitch rotors
for silent functioning;
- adjustment circuit board with remote control
panel.
- Refrigerant gas: R134a.

Accessories
DMP 20GL: OBLIGATORY ACCESSORY
-Front closure panel with external frame: realised
in polyurethane powder painted galvanised steel
(colour RAL 9010). Made up from a frame and
panel with air recovery and flow grid in anodised aluminium.
-Formwork: In galvanised steel, it allows unit

414

installation in niche. The formwork has appro- rooms heated by the radiant system reaching
priate fins for correct fixing to the wall and is normal working conditions.
prepared with openings for electric and hydraulic connections;
In the winter season the DMP dehumidifier can
be used to accelerate the temperature of the

Technical data
Mod.
Nominal dehumidification capacity (1)
Nominal input power (1)
Nominal input current (1)
Dehumidification capacity (2)
Input power (2)
Heating capacity produced - normal working conditions in heating mode (3)
Input power (3)
Maximum current absorbed
Peak current
Nominal water flow rate
Pressure drop

e Sound Pressure
Weight

DMP 20
20
340
2,3
49
390
1010
25
2,5
4
170
7
200
300
380
33
36

l/24h
W
A
l/24h
W
W
W
A
A
l/h
kPa
m3/h (min.)
Air flow rate
m3/h (max.)
dB [A]
kg

The performance refers to the following


conditions:

Dehumidification
(1) = Nominal conditions (min. fan speed)
Room air temperature: 26C
Relative humidity: 65%
Water input temperature: 15C

(2)
-

= Maximum conditions (min. fan speed)


Room air temperature: 35C
Relative humidity: 80%
Water input temperature: 15C

Heating
(3) = Rapid heating at normal conditions
(min. fan speed)
Room air temperature: 15C
Water input temperature: 35C

Power supply voltage = 230V/1/50Hz.


e Sound pressure measured in free field with directionality factor Q=2 at a distance of 1 m
(minimum fan speed).
In compliance with the ISO 3746

Dimensional data (mm)


DMP 20
B

DMP 20

A
Height
Width
Depth
Monobloc
dehumidifier unit

[mm] (A)
[mm] (B)
[mm] (C)

DMP 20 GL

Monobloc
dehumidifier
unit

External frame

Front panel

Formwork

590
750
210

678
843
8

596
761
18

606
771
227

DMP 20GL
B

External frame

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Front panel

Formwork

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

Cod.: SDMPUY.01 / 0903

415

05 PRECISION AIR CONDITIONERS


Aermec is well established in the data centre market, with a multiple year experience and
prestigious projects aimed at reducing the overall cost of ownership of modern data centres.
This process is achieved by applying state of the art product solutions with a strong focus on
integrated design and sophisticated analyses of individual data centre customer requirements,
with the aim of achieving a personalised and optimised solution for each and every individual
installation site.

Precision Air Conditioning units:


AX Air condensed direct expansion
WX Water condensed direct expansion
CW cooled water
Scroll compressors
Cooling capacity 665kW

DAS
06/60

R410A
UPFLOW

Back return
air
accessory

DOWNFLOW

Front return air

Boom return air


accessory

DUCTABLE PRECISION AIR CONDITIONERS


DEDICATED TO STRUCTURES FOR TELECOMMUNICATIONS, COMPUTER
ROOMS, DATA CENTERS, STERILIZED ROOMS AND LABORATORIES
POSSIBILITY OF TOTAL CONTROL OF TEMPERATURE, HUMIDIFICATION,
DEHUMIDIFICATION, AFTER HEATING AND FILTRATION
FEATURES
MODELS
DAS_D
down flow
DAS_U
up flow
VERSIONS
DAS_AX Air condensed direct expansion
DAS_WX Water condensed direct expansion
DAS_CW cooled water
FEATURES
The units Precision Air Conditioning DAS are designed for precision air conditioning of technological
medium-small rooms characterized from elevated
thermal loads to eliminate, such as computing centres
and other applications where high performances and
maximum reliability are required in a restrained area.
Precision Air Conditioning units can be customized
as per necessities, in order to offer a complete control
of temperature, of humidity and of air quality through accessories such as humidifier, after-heating (with
electric coil, water-coil or hot gas) and high efficiency
filters.
They are available in three different versions: with air
condensed direct expansion (standard supplied with
external remote condenser), with water or cooled
water condensed direct expansion.
STRUCTURE
The structure is composed by a painted aluminium
frame with black aluminium angles and removable
panels made of painted plate galvanized with epoxy
powders, which can grant a lasting finish.
The standard supplied unit is of grey-black colour
(RAL 7021). The colour light grey (RAL 7035) is
optional.

ACCESSORIES
Wide range of accessories, which can be
chosen by using the selection programme, that
permits also a real time-fast dimensioning of
the units.

418

FANS
DAS 626
The units are equipped with centrifugal fans with
double aspiration forward curved blades and EC
motor directly coupled with electronic control.
DAS 2860
The units are equipped with centrifugal fans with
double aspiration forward curved blades, 3-phase
asynchronous motor connected to the fan through
"belt and pulley".
Centrifugal fans with back curved blades are available for all the units (plug-fan) with EC motor
directly coupled with electronic control to minimize electric consumption and sound emissions.
FILTERS
Filters with corrugated separator, class of efficiency
G4 (according to EN 779). There are available as
optional, high efficiency filters with pre-filter, class
G3+F6.
ELECTRONIC REGULATION
The microprocessor regulation permits to visualize:
return air temperature, air temperature humidity
(optional), condensation pressure (optional) and cooled coil temperature and to regulate the load on
return air. The microprocessor manages also the working alarms.
Possibility of interfacing with supervision system
(there are different communication protocols available, ModBus, BACnet). Visualisation of all working
parameters in 4 languages.

COMPRESSOR
(ONLY FOR VERSIONS AX, WX)
High efficiency Scroll compressors with low electric
absorption.
EVAPORATOR
(ONLY FOR VERSIONS AX, WX)
The finned pack evaporation coil is with copper pipes
internally corrugated and aluminium fins blocked
through pipes' mechanical expansion. The fins are
covered with hydrofilic film, which, by guaranteeing
a successful removal of water drops from the surface,
it permits to increase the coil's performances.
CONDENSER
(ONLY FOR VERSIONS WX)
Braze welded plate heat exchanger in steel AISI 316.
The heat exchanger is externally coated with closed
cells neoprene anticondensate material.
COOLED WATER COIL
(ONLY FOR VERSIONS CW)
The finned pack cooling coil is with internally lined
copper pipes and aluminium fins blocked through
mechanical expansion of pipes. The fins are coated
with hydrophilic film which guarantees a succesful
removal of water drops from the surface and permits
to increase the coil's performances.
Modulating 3-way valve is standard supplied.

CONFIGURATOR
Field
1, 2, 3
4

5, 6

7, 8

DESCRIPTION
DAS
MODELS
D down flow
U up flow
SIZES
06-08-10-13-15-17-20-22-26-28-31-35-40-45-50-55-60

VERSIONS
AX Air condensed
WX Water condensed
CW cooled water

NUMBER OF COMPRESSORS
0 without compressor (only for CW versions)
1 (can be selected for versions AX and WX)
2 d(can be selected for versions AX and WX)

10

POWER SUPPLY
0 400V/3/50Hz

TABLE OF COMPRESSORS' COMPATIBILITY


N. of compressors

DAS_U
"all versions"
6
8
10
13
15
17
20
22
26
28
31
35
40
45
50
55
60

Possible configurations

1
single

2
tandem

TABLE OF COMPRESSORS'COMPATIBILITY
N. of compressors

DAS_D
"all versions"
6
8
10
13
15
17
20
22
26
28
31
35
40
45
50
55
60

1
single

2
tandem

Possible configurations

419

TECHNICAL DATA
DAS

Cooling capacity

FANS
Type
Number of fans
Air ow rate
Maximum available
static pressure
SOUND DATA
Discharge sound
power

VERSIONS MOD
U
AX
D
U
WX
D
U
CW
D

U.M.
kW
kW
kW
kW
kW
kW

06
6,4
6,5
6,5
6,6
7,6
7,6

08
8,2
8,4
8,2
8,4
9,2
9,7

10
10,6
10,8
10,8
11,0
11,2
11,7

13
13,7
13,9
13,9
14,1
14,7
14,7

15
15,4
15,6
15,8
16,0
16,6
16,6

17
17,8
18,0
18,1
18,3
18,1
18,1

20
21,1
21,5
21,8
22,2
21,8
21,8

22
22,5
22,9
22,5
22,9
23,4
23,4

26
27,4
27,4
27,5
27,5
25,6
25,6

28
26,5
26,1
26,5
26,1
34,2
34,2

All
All
All
All
All

U/D
U/D
U/D
U
D

n
m3/h
Pa
Pa

EC
1
1980
564
523

EC
1
2700
507
442

EC
1
3420
295
191

EC
1
3600
315
307

EC
1
4320
415
405

EC
1
5040
198
190

EC
2
6120
335
327

EC
2
7200
185
177

EC
2
7200
70
57

AC
AC
AC
AC
AC
AC
AC
AC
1
1
1
1
1
2
2
2
8640 10080 11880 13320 13320 15120 15120 16560
160
35
35
25
25
255 255
35
75
265 165 175 175
35
35
75

U
D
U
D
U
D
U
D

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)

72
71
58
62
58
58
43
43

78
77
63
68
63
63
49
48

81
80
66
71
66
66
51
51

78
77
63
67
63
63
48
48

74
73
62
66
62
62
47
47

78
77
65
70
65
65
50
50

82
81
67
72
67
67
53
52

86
85
71
76
71
71
57
56

86
85
71
76
71
71
57
56

All
All
All
Intake sound power
All
Sound power radia- All
ted from the unit
All
All
Sound pressure
at 3m
All

EC
AC

90
87
79
68
79
70
64
55

31
29,8
29,4
30,1
29,7
38,0
38,0

93
91
81
71
81
73
66
58

35
34,2
33,7
35,0
34,5
43,7
43,7

92
90
81
71
81
72
67
58

40
38,7
38,2
39,0
38,5
47,6
47,6

94
92
83
73
83
75
68
60

45
43,0
43,2
43,0
43,2
50,6
50,6

94
92
83
73
83
75
69
60

50
50,3
49,6
50,9
50,2
51,3
51,3

97
89
84
69
84
71
70
56

55
56,0
55,3
57,4
56,6
58,5
58,5

97
89
84
70
84
71
70
57

60
62,2
61,5
64,7
63,8
62,3
62,3

98
91
86
71
86
73
72
58

Centrifugal fan with forward curved blades and motor directly coupled with electronic control.
Centrifugal fan with forward curved blades and 3-phase asynchronous motor connected through belt and pulley.
COOLING
External air temperature
Relative humidity temperature
External air temperature

24C
45%
35C

Sound power
All the quoted sound data have been measured relatively to the values limited to the third-octave-band, using a sound intensity measurer regulated by a real time
anlyser, in accordance with the regulation BS EN ISO9614 Part 1: 1995.
All the quoted sound power levels are calculated according to the sound intensity measured in compliance with BS EN ISO9614 Part 1: 1995.
Sound pressure
The sound pressure levels are calculated according to the sound power by using the half-hemisferic method in which the source of noise is situated on a crossing
point compared with two delimitations, for example the oor and a single wall.
Note: For further informations, please refer to the selection software Aermec Performance Selection.

420

DIMENSIONS
DAS
Height
Width
Depth

VERSIONS
AX-WX-CW
AX-WX-CW
AX-WX-CW
AX
WX
CW

A
B
C

Weight

MOD.
U-D
U-D
U-D
U-D
U-D
U-D

U.M.
mm
mm
mm
Kg
Kg
Kg

06
08
10
13
15
17
20
22
26
28
31
35
40
45
50
55
60
1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940 1940
670
670
670
990
990
990 1310 1310 1310 1460 1460 1835 1835 1835 2170 2170 2170
670 670 670 670 670 670 670 670 670 750 750 750 750 750 750 750 750
173
179
184
220
231
232
303
303
307
412
412
474
497
563
619
636
640
188
199
203
243
261
264
340
340
343
468
468
534
562
652
709
729
733
138
147
150
190
195
195
246
246
246
349
347
408
429
440
485
498
498
DAS 6-8-10

DAS 13-15-17

DAS 20-22-26

A
A

DAS 35-40-45

DAS 28-31

DAS 50-55-60

A
A
A

B
C

COUPLING

DAS 06
DAS 08
DAS 13
DAS 15
DAS 17
DAS 20
DAS 22
DAS 26
DAS 28
DAS 31
DAS 35
DAS 40
DAS 45
DAS 50
DAS 55
DAS 60

Code of remote
condenser

A
Height
(mm)

B
Width
(mm)

C
Depth
(mm)

Wasted
thermal
power
kW

Sound
power
dB(A)

Sound
pressure
dB(A)
@10m

CR12
CR16
CR16
CR22
CR22
CR30
CR22
CR30
CR30
CR50
CR30
CR50
CR50
CR65
CR50
CR65
CR50
CR65
CR50
CR65
CR50
CR65
CR65
CR80
CR80
CR105
CR80
CR105
CR80
CR105
CR80
CR105

972
972
972
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167
1167

907
907
907
1102
1102
1102
1102
1102
1102
2184
1102
2184
2184
2184
2184
2184
2184
2184
2184
2184
2184
2184
2184
3565
3565
3565
3565
3565
3565
3565
3565
3565

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000

14
19
19
25
25
31
25
31
31
54
31
54
54
71
54
71
54
71
54
71
54
71
71
88
88
113
88
113
88
113
88
113

74
74
74
78
78
78
78
78
78
81
78
81
81
81
81
81
81
81
81
81
81
81
81
83
83
82
83
82
83
82
83
82

46
46
46
50
50
50
50
50
50
53
50
53
53
53
53
53
53
53
53
53
53
53
53
55
55
55
55
55
55
55
55
55

CR 12-16-22-30

CR 50-65

B
C

CR 80-105

Cod.: SDASUY.00 / 1401

Dimensions in horizontal position


Sizes

A
B

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293730
www.aermec.com

421

Precision Air Conditioning units:


X
Air-condensed direct expansion
W Water-condensed direct expansion
Scroll compressors
Cooling capacity 16150kW

DAC
09/31

R410A
DOWNFLOW

DUCTABLE PRECISION AIR CONDITIONERS


DEDICATED TO STRUCTURES FOR TELECOMMUNICATIONS, COMPUTER
ROOMS, DATA CENTRES, STERILIZED ROOMS AND LABORATORIES
POSSIBILITY OF TOTAL CONTROL OF TEMPERATURE, HUMIDIFICATION,
DEHUMIDIFICATION, AFTER HEATING AND FILTRATION
FEATURES
MODELS
DAC_D
down flow
VERSIONS
DAC_X
Air-condensed direct expansion
DAC_W Water-condensed direct expansion
FEATURES
The Precision Air Conditioning units DAC are designed for precision air conditioning of technological
rooms characterized from elevated thermal loads to
be eliminated, such as computing centres and other
applications where high performances and maximum
reliability are required.
Precision Air Conditioning units can be customized
as per necessities, in order to offer a complete control
of temperature, of humidity and of air quality through
accessories such as humidifier, after-heating and high
efficiency filters.
In order to guarantee the maximum realiability and
flexibility, there are available whether solutions with
double circuit or solution with different cooling
mediums (dual cool solution with a direct expansion circuit and a cooled water circuit in the same
unit).
These coolers are designed and optimized for wor-

EC FANS
PLUG-FAN

ASYMMETRICAL SCROLL
COMPRESSORS

king with refrigerant R410A, which is not dangerous


for the ozone.
STRUCTURE
The structure is composed by a painted aluminium
frame with black aluminium angles and removable
panels made of painted plate galvanized with epoxy
powders, which can grant a lasting finish.
The standard supplied unit is of colour grey-black
(RAL 7021). The colour light grey (RAL 7035) is optional.
COILS
Coils with wide surface, positioned in an ideal way to
optimize the air flow and the heat transfer, are realized in copper pipes of cooling quality with aluminium fins linked in a mechanical way.
COMPRESSORS
Scroll compressor with high performances and low
power absorption. On the strenght of the size, the
units can have a single or tandem compressor.
In the tandem configuration it is possible to vary the
power given on the different capacity steps, activating
one of the two compressors one by one, when necessary.

HUMIDIFIER
"ACCESSORY"

DOUBLE COIL

FANS
Centrifugal fans with back curved blades (plug-fan)
with EC motor directly coupled with electronic control to minimize electric consumption and sounds
emissions.
FILTERS
Filters with corrugated separator, class of efficiency
G4 (according to EN 779).
There are available as optional high efficiency filters
with pre-filters, class G3+F6.
ELECTRONIC REGULATION
The microprocessor regulation permits to visualize:
return air temperature, return air temperature humidity (optional), condensation pressure (optional) and
cooled coil temperature and to regulate the load on
return air. The microprocessor manages also the working alarms.
Possibility of interfacing with supervision system
(there are different communications protocols available, ModBus, BACnet). Visualisation of all working
parameters in 4 languages.

ACCESSORIES
Wide range of accessories, which can be
chosen by using the selection programme, that
permits also a real-time fast dimensioning of
the units.

422

CONFIGURATOR

Field
1, 2, 3

DESCRIPTION
DAC

4,5

FRAME
09, 12, 15, 18
19, 25, 31

MODEL
D down flow

7, 8, 9

SIZES
16150

10

CIRCUIT 1

13

NUMBER OF COMPRESSOR CIRCUIT 2


0 Without compressor (only for version F)
1 n1 compressor
2 n2 Tandem compressors

14

POWER SUPPLY
0 400V/3/50Hz

X Air-condensed direct expansion


W Water-condensed direct expansion
11

NUMBER OF COMPRESSORS CIRCUIT 1


1 n1 compressor
2 n2 Tandem compressors

12
0
X
W
C
F

CIRCUIT 2
Without circuit 2
air-condensed direct expansion
Water-condensed direct expansion
Cooled water
free-cooling

PLANT-ENGINEERING SOLUTION
OPEN PASSAGES
In low density's applications (< 5 kW/rack) this
configuration permits to distribute the air in
front of racks, without having an appreciable
mixing between cold air and hot air flows, as
happens instead in rooms with a traditional
configuration. This is an easy and flexible
solution, if necessary, because it permits to
change rapidly, if necessary, the room's layout.

CLOSED PASSAGES
When power density in the server rooms
grows, a solution with open passages is no
more able to avoid mixing between hot and
cold air flows.
For high-medium power density applications
(from 6 to 20 kW/rack) it must be used the
solution with closed passages. The reduction
through hot and cold passages avoids the risk
of any mixing between the two air flows,
ensuring to the server the needed cold air and
increasing the global efficiency of the system.

423

CONFIGURATIONS

X200

X2X2

W2W2

Air-condensed direct expansion configuration


with single refrigerating circuit. It can have one
or two compressors, depending on the size of
the unit.
The ambient air is cooled in the passage
through the evaporation coil. The
condensation takes place in the remote
condenser positioned outside.

Air-condensed direct expansion configuration


with double refrigerating circuit.
Each circuit has two tandem compressors of
different sizes to increase the capacity steps
and to improve the energy efficiency to partial
loads.
The ambient air is cooled in the passage
through the two evaporation coils, which are
completely independent.
The condensation takes place in the remote
condensers positioned outside (one for each
circuit).

Water-condensed direct expansion with


double refrigerating circuit.
Each circuit has two tandem compressors of
different sizes to increase the capacity steps
and to improve the energy efficiency to partial
loads.
The ambient air is cooled in the passage
through the two evaporation coils, which are
completely independent.
The condensation takes place in plate heat
exchangers (one for circuit) inside the unit, in
which the refrigerating fluid gives heat to water
flow (or water and glycole) , which is then
cooled externally through two independent dry
coolers.

X2C0

W2C0

W2F0

"Dual cool" configuration with two different


refrigerating circuits powered by two different
cooling mediums: an air-condensed direct
expansion circuit (coupled with an external
remote condenser) and a cooled water circuit.
The electronic regulation allows to design the
main circuit while the other is maintained of
back-up, occurring only when the primary
circuit is not working.

"Dual cool" configuration with two different


refrigerating circuits powered by two different
cooling ways: a water-condensed direct
expansion circuit and a cooled water circuit.
The electronic regulation allows to design the
main circuit while the other is maintained of
back-up, occurring only when the primary
circuit is not working.

"Dual cool" configuration which couples to the


water-condensed direct expansion circuit a
free-cooling circuit. When the outdoor
temperature is sufficiently low, the regulation
occurs on the 3-way valve deviating the glycolsolution from the plate heat exchanger to the
free-cooling coil, disabling in this way the
compressors.

424

DIMENSIONS
DAC
Height
Width
Depth

VERSIONS
X-W
X-W
X-W

A
B
C

MOD.
D
D
D

DAC9

U.M.
mm
mm
mm

DAC12

12
1980
1200
890

DAC19

18
1980
1800
890

19
1980
1985
890

25
1980
2549
890

31
1980
3113
890

DAC18

15
1980
1500
890

DAC15

09
1980
900
890

DAC25

DAC31

A
A
A
B
C

B
C

Cod.: SDACXWUY.00/1402

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293730
www.aermec.com

425

Precision Air Conditioning units:


C cooled water
Cooling capacity 6200kW

DAC
06/35

R410A

Coils DAC_N-R

DOWNFLOW

Coils DAC_D

DUCTABLE PRECISION AIR CONDITIONERS


DEDICATED TO STRUCTURES FOR TELECOMMUNICATIONS, COMPUTER
ROOMS, DATA CENTERS, STERILIZED ROOMS AND LABORATORIES
POSSIBILITY OF TOTAL CONTROL OF TEMPERATURE, HUMIDIFICATION,
DEHUMIDIFICATION, AFTER HEATING AND FILTRATION
FEATURES
MODELS
DAC_D
down flow
VERSIONS
DAC_C
cooled water
FEATURES
The cooled water Precision Air Conditioning units
DAC are designed for precision air conditioning of
technological rooms characterized from elevated
thermal loads to be eliminated, such as computing
centres and other applications where high performances and maximum realiability are required.
Precision Air Conditioning units can be customized
as per necessities, in order to offer a complete control
of temperature, of humidity and of air quality through
accessories such as humidifier, after-heating and high
efficiency filters.
STUCTURE
The structure is composed by a painted aluminium
frame with black aluminium angles and removable
panels made of painted plate galvanized with epoxy

EC FANS - PLUGFAN

HUMIDIFIER
"ACCESSORY"

powders, which can grant a lasting finish.


The standard supplied unit is of colour grey-black
(RAL 7021). The colour light grey (RAL 7035) is optional.
COOLED WATER COIL
The finned pack cooling coil is with internally lined
copper pipes and aluminium fins blocked through
mechanical expansion of pipes. The fins are coated
with hydrophilic film which guarantees a succesful
removal of water drops from the surface and permits
to increase the coils's performances.
Modulating 3-way valve is standard supplied.
"EC" FANS
Centrifugal fans with back curved blades (plug-fan)
with EC motor directly coupled with electronic control to minimize electric consumption and sounds
emissions.
FILTERS
Filters with corrugated separator, class of efficiency
G4 (according to EN 779).

2-WAY VALVE
"STANDARD"

3-WAY VALVE
"ACCESSORY"

There are available as optional high efficiency filters


with pre-filters, class G3+F6.
ELECTRONIC REGULATION
The microprocessor regulation permits to visualize:
return air temperature, air temperature humidity
(optional), condensation pressure (optional) and cooled coil temperature and to regulate the load on
return air. The microprocessor manages also the working alarms.
Possibility of interfacing with supervision system
(there are different communications protocols available, ModBus, BACnet). Visualisation of all working
parameters in 4 languages.

ACCESSORIES
Wide range of accessories, which can be
chosen by using the selection programme, that
permits also a real time-fast dimensioning of
the units.

426

CONFIGURATOR
Field
1, 2, 3
4

DESCRIPTION
DAC
FRAME VERSIONS
N Narrow (depth 600mm)
R Regular (depth 890mm)
D Dedicated

5, 6

FRAME
06, 09, 12, 15
18, 22, 25, 31, 35
MODEL
D down flow

8, 9, 10

SIZES
085255

11

CIRCUIT 1
C cooled water

12

COIL CIRCUIT 1
0 Without Circuit 1 (only versions N-R)
H High capacity (only versions R-D)
L Low capacity (only versions R-D)

13

CIRCUIT 2
0 Without Circuit 2
C cooled water

14

COIL CIRCUIT 2
0 Without Circuit 2 (only versions N-R)
H High capacity (only versions R-D)
L Low capacity (only versions R-D)

15

POWER SUPPLY
0 400V/3/50Hz

DAC
FRAME
06
09
12
15
18
22
25
31
35

FRAME VERSIONS
R

Possible configurations

427

PLANT-ENGINEERING SOLUTIONS
OPEN PASSAGES
In low density's applications (< 5 kW/rack) this
configuration permits to distribute the air in
front of racks, without having an appreciable
mixing between cold air and hot air flows, as
happens instead in rooms with a traditional
configuration. This is an easy and flexible
solution, because it permits to change rapidly,
if necessary, the room's layout.

CLOSED PASSAGES
When power density in the server room grows,
a solution with open passages is no more able
to avoid mixing between hot and cold air
flows. For high-medium power density
applications (from 6 to 20 kW/rack) it must be
used the solution with closed passages. The
reduction through hot and cold passages
avoids the risk of any mixing between the two
air flows, ensuring to the server the needed
cold air and increasing the global efficiency of
the system.

CONFIGURATIONS

C000
When cooled water monocircuit system is
preferred, hot air of the room is aspirated
through the efficient cooling coil of Precision
Air Conditioning C000 and the heat is
transferred to a cooled water system.
Controlling the regulation 2-way or 3-way
valve, the smart microprocessor can reach a
precise control of temperature and humidity.

C0C0
In the system C0C0, the cooling coils are
divided into two independent systems, each of
them with a modulating 3-way valve,
managing in this way the cooling from two
separate chillers.
To be on the safe side, the double-circuitconfiguration C0C0 offers redundancy 2N.

428

DIMENSIONS

DAC_N_06_C

DAC_N
Height
Width
Depth

C
DAC_N_09_C

U.M.
mm
mm
mm

A
B
C

06
1980
684
600

09
1980
963
600

C
DAC_N_12_C

12
1980
1242
600

A
A

C
DAC_R_09_C

DAC_R
Height
Width
Depth

C
DAC_R_12_C

U.M.
mm
mm
mm

A
B
C

09
1980
963
890

12
1980
1242
890

Height
Width
Depth

A1
A2
B
C

U.M.
mm
mm
mm
mm

A1

A1

A1

A2

A2
B

DAC_D_22_C

DAC_D

18
1980
1800
890

A2
B

DAC_D_18_C

15
1980
1521
890

DAC_R_18_C

A1

A2
C

C
DAC_R_15_C

A1

C
DAC_D_25_C

A2

C
DAC_D_31_C

C
DAC_D_35_C

Cod.: SDACUY.00 / 1402

18
22
25
31
35
1980
1980
1980
1980
1980
600 minimum 600 minimum 600 minimum 600 minimum 600 minimum
1800
2200
2500
3100
3500
890
890
890
890
890

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293730
www.aermec.com

429

06

NEW

SE

Reversible heat pump split system DC Inverter


Wall mounted monosplit
Cooling capacity 2,56,5kW
Heating capacity 2,77,0kW

R410A

SE_W

Seasonal Energy Efficiency


See Technical data

SE

Characteristics
Split heat pump suitable for cooling / heating in
the residential environment.
New design features and modern forms that are
well suited to any style of interior.
Five modes of operation (cooling, heating, dehumidication, ventilation Automatic and Only), to
guarantee optimum comfort.
The environmental comfort is also closely related
to the sound level and is especially important in
studies and bedrooms. The indoor units SE, ensure comfort throughout the year by distributing
air quietly.
Operation heat pump with reverse cycle refrigerator and defrost control
Fan tangential 4 speed directly selected (Minimum, Average, Maximum, Turbo)
DC Inverter rotary compressor
Microprocessor control
Infrared remote controller with liquid crystal
display to control all functions
Emergency control possibility if the remote
controller batteries are at (Button AUTO on
internal unit)

432

Front panel display showing operating modes


and temperature. The display can be activated or deactivated from the remote controller
(LIGHT)
A handy timer allows you to set up and program the startup and shutdown within a time
span of 24 hours, the hours you select, and
even in your absence.
Function Night Comfort (SLEEP)
The function adjusts the room temperature by
reproducing the curve of body temperature
during the night, thus ensuring an adequate
physical and mental rest, whose bene translate into increased productivity and efciency.
Extended Ventilation (X-FAN) function prevents the growth of mould in the internal unit
during Cooling and Dehumidication Modes
Intelligent pre-heat function to prevent jets of
cold air (Heating Mode)
Auto-diagnostic function
Auto-Restart function after a power cut
External unit defrost function
External unit with condensate connection

Cleanable air lter


Horizontally adjustable air discharge louvres
Motorised deector louvres controlled by the
remote controller to vertically adjust the discharge air, with 5 xed positions or oating
(SWING)
Flare type refrigerant connections
Simple installation and maintenance

Technical data
Internal Unit
External Unit
nominal
(minmax)
nominal
(minmax)

Cooling capacity
Power input

kW
kW
kW
kW
l/h

Condensate rate
Energy efficiency class
SEER
Pdesignc
nominal
(minmax)
nominal
(minmax)
Energy efficiency class
SCOP
Pdesignh
EER
COP

Seasonal Energy
Efficiency
Heating capacity
Power input
Seasonal Energy
Efficiency
(evarage)

(1)
kW
kW
kW
kW
kW
(1)

(2)
(2)
(3)

Power input nominal


Internal unit
Air ow rate
Sound power
Sound pressure
External Unit
Air ow rate
Sound power
Sound pressure
Compressor
Ref. connections

Refrigerant lines

kW

max/med/min
max/med/min
/max/med/min

m3/h
dB(A)
dB(A)

max
max
max

m3/h
dB(A)
dB(A)
type

(4)

Liquid
Gas
Liquid
Gas
piping length
drop

max
max

Power supply

inch
inch
mm / inch
mm / inch
m
m
V ~ Hz

SE250W
SE250
2,50
(0,60-2,80)
0,80
(0,12-1,30)
0,8
A+
5,8
2,5
2,75
(0,60-3,00)
0,78
(0,12-1,40)
A+
4,0
2,5
3,12
3,53
1,4

SE350W
SE350
3,20
(0,60-3,50)
1,02
(0,12-1,40)
1,4
A++
6,1
3,2
3,40
(0,60-3,80)
0,99
(0,12-1,50)
A+
4,0
3,2
3,14
3,42
1,5

SE500W
SE500
5,27
(1,26-6,60)
1,62
(0,38-2,65)
1,8
A++
6,1
5,2
5,80
(1,12-6,80)
1,76
(0,35-2,65)
A+
4,0
4,5
3,25
3,30
2,6

SE700W
SE700
6,45
(2,53-6,80)
2,18
(0,60-2,65)
2,0
A++
6,1
6,4
7,00
(2,53-7,60)
2,22
(0,60-2,80)
A+
4,0
5,8
2,96
3,15
2,8

SE250W

SE350W

SE500W

SE700W

400/300/250

400/300/250

780/650/550

800/700/550

46/43/40
34/31/28

47/43/40
34/31/28

53/50/45
43/37/33

57/52/49
47/42/39

SE250
1600
60
50

SE350
SE500
2200
3200
63
63
51
56
Rotary DC Inverter

SE700
4000
68
58

1/4"
3/8"
6,35 / 1/4"
9,52 / 3/8"
15
10

1/4"
1/4"
1/2"
1/2"
6,35 / 1/4"
6,35 / 1/4"
12,7 / 1/2"
12,7 / 1/2"
20
25
10
10
220-240V~50Hz

1/4"
5/8"
6,35 / 1/4"
15,9 / 5/8"
25
10

Cooling (EN-14511 e EN-14825)


Ambient air temperature 27C b.s/ 19 b.u.; External air temperature 35C; Max speed; Refrigerant line length 5m
Heating (EN-14511 e EN-14825)
Ambient air temperature 20C b.s; External air temperature 7C b.s/ 6C b.u; Max speed; Refrigerant line length 5m
min = minimum speed; max = maxim speed
(1) In accordance with Standard EN-14511e EN-14825
(2) EER/COP in accordance with (EN-14511), declared only for the purpose of tax deductions into force upon completion of this publication
(3) The rated power input is the maximum electrical power absorbed by the system, according to the legislation EN-60335 - 1 e EN-60335 - 2 - 40
(4) Sound pressure measured at 1m distance from front in semi-anechoic chamber.

Dimensional and Weight

C
B

Height
Width
Depth
Weight

A
B
C

SE

mm
mm
mm
kg

SE250W

SE350W

SE500W

SE700W

SE250

SE350

SE500

SE700

265
790
174
8.5

265
790
174
8.5

298
940
200
12

315
1007
219
15

540
776
320
27

596
842
320
31

700
963
396
45

790
1000
427
55

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

433

Cod.: SSEUY.00 / 1501

SE_W

SI

Split system air conditioner and heat pump


Wall mounted monosplit with capacity from 2.6 a 6.45kW
DC Inverter Technology
Air ioniser standard

R410A

Seasonal Energy Efficiency


See Technical data

SI_E

SI_C

Characteristics
Available in 4 different capacity sizes.
Refrigerant R410A
Heat pump operation with reversible refrigerant cycle and defrost control
Tangential type fan with 4 speeds:
- 3 speeds directly selected (Minimum, Medium, Maximum)
- One Super High speed when the Rapid Cooling/Heating (TURBO) function is activated, to
achieve the required temperature as quickly as
possible
DC Inverter rotary compressor
Extremely low noise operation
Microprocessor control
Infrared remote controller with liquid crystal
display to control all functions
Emergency control possibility if the remote
controller batteries are at (Button AUTO on
internal unit)
Front panel display showing operating modes
and temperature. The display can be activat-

434

ed or deactivated from the remote controller Motorised deector louvres controlled by the
(LIGHT)
remote controller to vertically adjust the disTimer to programme clock functions (switch
charge air, with 5 xed positions or oating
on or off)
(SWING)
Operating modes: Cooling, Heating, Dehu- Flare type refrigerant connections
midication, Automatic or Ventilation Only
Simple installation and maintenance
Air ioniser standard
Night-time Health function (SLEEP)
Energy Saving function
Rapid Cooling/Heating function (TURBO)
Extended Ventilation (X-FAN) function prevents the growth of mould in the internal unit
during Cooling and Dehumidication Modes
Intelligent pre-heat function to prevent jets of
cold air (Heating Mode)
Auto-diagnostic function
Auto-Restart function after a power cut
External unit defrost function
External unit with condensate connection
Cleanable air lter
Horizontally adjustable air discharge louvres

Technical data
Internal Unit
External Unit
Cooling capacity
Power input
SEER
Energy efficiency class
Condensate rate
Heating capacity
Power input
SCOP
Energy efficiency class
Power input nominal *
Airow rate (SI_E)
Sound pressure max (SI_E)
Sound pressure max (SI_C)
Compressor
Max line length
Max elevation change
(Internal - external unit)

SI090E
SI090C
2600
870
5,6
A+

W (nominal)
W (nominal)

l/h
W (nominal)
W (nominal)

0,8
3000
900
3,8
A
1550
600/520/370/280
38
51

W
m3/h
dB(A)
dB(A)
m

15

10

liquid
gas
mm (inch) liquid
mm (inch) gas
V ~ Hz

Refrigerant connections
Refrigerant lines
Power supply

SI120E
SI180E
SI120C
SI180C
3500
5275
1150
1600
5,1
5,4
A
A
1,4
1,8
3800
5570
1100
1750
3,8
3,8
A
A
1650
2650
680/560/410/300
800/680/560/460
39
44
53
55
Rotary DC Inverter
20
25
10

1/4
3/8"
6,35 (1/4)
9,52 (3/8)

SI240E
SI240C
6450
2180
5,1
A
2
7000
2220
3,8
A
2800
1000/800/700/550
47
58
25

10

10

1/4
1/4
3/8"
1/2
6,35 (1/4)
6,35 (1/4)
9,52 (3/8)
12,7 (1/2)
230V ~ 50Hz

1/4
5/8
6,35 (1/4)
15,9 (5/8)

Sound pressure measured at 1m distance from front in semi-anechoic chamber


* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825

Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

5m

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

20C
7C db ; 6C wb
5m

Dimensional data (mm)

SI_C

C
C

SI

SI

090E

120E

180E

240E

090C

120C

180C

240C

Height

283

283

305

315

540

540

700

790

Width
Depth
Weight

B
C
kg

770
201
8

770
201
9

865
215
12

1007
219
14,5

776
320
28

848
320
30

955
396
46

980
427
55,5

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

435

Cod.: SSIUY.00 / 1502

SI_E

HWI

Split system air conditioner and heat pump


Wall mounted monosplit with capacity from 2.6 to 6.45kW
DC Inverter Technology
Air ioniser standard

R410A

HWI_E
Seasonal Energy Efficiency
See Technical data

HWI_C

Characteristics
Available in 4 different capacity sizes
Refrigerant R410A
Heat pump operation with reversible refrigerant cycle and defrost control
Tangential type fan with 4 speeds:
- 3 speeds directly selected (Minimum, Medium, Maximum)
- One Super High speed when the Rapid Cooling/Heating (TURBO) function is activated, to
achieve the required temperature as quickly as
possible
DC Inverter rotary compressor
Extremely low noise operation
Microprocessor control
Infrared remote controller with backlit liquid
crystal display to control all functions
Emergency control possibility if the remote
controller batteries are at (Button AUTO on
internal unit)
Front panel display showing operating modes
and temperature. The display can be activated or deactivated from the remote controller

436

(LIGHT)
Clock on remote controller
Timer to programme clock functions (switch
on and/or off)
Operating modes: Cooling, Heating, Dehumidication, Automatic or Ventilation Only
Air ioniser standard
Night-time Health function (SLEEP)
Energy Saving function
Rapid Cooling/Heating function (TURBO)
Personal Climate (I FEEL) function allows the
user to have around him the desired climate
through the internal sensor of the remote
controller
Extended Ventilation (X-FAN) function prevents
the growth of mould in the internal unit during
Cooling and Dehumidication Modes
Antifreeze function prevents the internal space
temperature dropping below 8C during the
winter period
Intelligent pre-heat function to prevent jets of
cold air (Heating Mode)

Auto-diagnostic function
Auto-Restart function after a power cut
External unit defrost function
External unit with condensate connection
Cleanable air lter
Horizontally adjustable air discharge louvres
Motorised deector louvres controlled by the
remote controller to vertically adjust the discharge air, with 8 xed positions or oating
(SWING)
Flare type refrigerant connections
Simple installation and maintenance

Technical data
Internal Unit
External Unit
Cooling capacity
Power input
SEER
Energy efficiency class
Condensate rate
Heating capacity
Power input
SCOP
Energy efficiency class
Power input nominal *
Airow rate (HWI_E)
Sound pressure max (HWI_E)
Sound pressure max (HWI_C)
Compressor
Max line length
Max elevation change
(Internal - external unit)

HWI091E
HWI091C
2600
720
6,4
A++

W
W

l/h
W
W

0,8
2750
720
4,0
A+

W
m3/h
dB(A)
dB(A)
m

20

10

Refrigerant lines
Power supply

HWI181E
HWI181C
5275
1620
5,6
A+

HWI241E
HWI241C
6450
1940
5,8
A+

1,4
1,8
3650
5275
1100
1600
3,8
3,8
A
A
1580
2500
650/500/400/300
850/780/650/500
48
47
53
55
Rotary DC Inverter
20
25

1550
650/500/400/300
48
53

liquid
gas
mm (inch) liquid
mm (inch) gas
V ~ Hz

Refrigerant connections

HWI121E
HWI121C
3500
1100
6,4
A++

10

1/4
3/8"
6,35 (1/4)
9,52 (3/8)

2,0
6450
1910
3,8
A
3050
1000/800/700/600
49
60
25

10

10

1/4
1/4
3/8"
1/2
6,35 (1/4)
6,35 (1/4)
9,52 (3/8)
12,7 (1/2)
230V ~ 50Hz

1/4
5/8
6,35 (1/4)
15,9 (5/8)

Sound pressure measured at 1m distance from front in semi-anechoic chamber


* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825

Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

5m

20C
7C db ; 6C wb
5m

Dimensional data (mm)

HWI_E

HWI_C
A
A
C

HWI

HWI

091E

121E

181E

241E

091C

121C

181C

241C

Height

275

275

298

315

540

540

700

790

Width
Depth
Weight

B
C
kg

845
189
10

845
189
10

945
208
13

1018
223
15,5

798
320
30

848
320
33

955
396
46

980
427
62,5

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

437

Cod.: SHWI1UY.02 / 1502

LCI

E
Split system reversible heat pump for light commercial applications XT CO
ER O
Monosplit with capacity from 2.7 to 17kW
N L
DO AL ING
DC Inverter Technology

R410A
Seasonal Energy Efficiency
See Technical data

W TE W
M
I
N
TO PE TH
-1 RAT
5 UR
C
E

LCI_F

LCI_C

LCI_D

Wired panel

Controller

Characteristics
The LCI series consist of an external Inverter
unit connected to 3 types of internal units
External unit:
LCI: 8 sizes of different capacity with single
phase power
LCI_T: 4 sizes of different capacity with three
phase power
Internal unit:
Cassette (False ceiling mounted) (600x600):
LCI036CS - 051CS
(It is required to connect with accessory
LCIGL40S)
Cassette (False ceiling mounted) (840x840):
LCI071C - 086C - 101C -121C
(It is required to connect with accessory
LCIGL40)
Cassette (False ceiling mounted) (910x910):
LCI141CB - 161CB
(It is required to connect with accessory
LCIGL40B)
Floor Ceiling (Wall or ceiling mounted):
LCI026F - 036F - 051F - 071F - 086C - 101F 121F - 161F
Ducted (Horizontal installation):
LCI026D - 036D - 051D - 071D - 086D - 101D

438

- 121D - 141D - 161D


Refrigerant R410A
Heat pump operation with reversible refrigerant
cycle and defrost control
The DC Inverter compressors are selected to
maximise efficiency, reduce consumption and
minimise starting current
External unit fitted with one or two fans with
DC Inverter motor with continuous speed control
Internal unit with 3 speed fan assembly
Wired panel and remote controller standard on
all internal units
Infrared remote controller with liquid crystal display to control all functions
Wired panel with liquid crystal display to control all functions
Microprocessor control
Possibility to set the ambient temperature sensor
in the intake of the internal unit or in the wired
panel
Timer for programming switch on or off
Operating modes: Cooling, Heating,
Dehumidification, Automatic or Ventilation
Only

Extremely low noise operation


Auto-Restart function: restart as default, can be
deactivated
Condensate discharge pump in version LCI_C CS - CB
Simple installation and maintenance
Air filter easily removed and cleaned
Flare type refrigerant connections
Maximum refrigerant line lengths:
- up to 20m for units LCI026, LCI036 and
LCI051
- up to 30m for units LCI071, LCI086, LCI101,
LCI101T
- up to 50m for units LCI121, LCI121T, LCI141,
LCI141T and LCI161T
Condensation control device standard; allows
operation in Cooling with external temperatures down to -15C

Technical data
External Unit (E.U.) LCI
Internal Unit (I.U.) LCI
Cooling capacity

036
051
036CS 051CS
3500
5000
900
1600
3900
5500
5,10
5,10
A
A
1090
1600
300
550
1400
1750
5,0
7,2
1,3
2,3
6,2
7,8
3800
5500
900
1400
4100
6500
3,8
3,8
A
A
1050
1580
200
500
1200
1900
4,90
7,6
1,0
2,1
5,4
8,4

(min)
(max)

SEER
Energy efficiency class
Power input total

(min)
(max)

Current input

(min)
(max)

Heating capacity

(min)
(max)

SCOP
Energy efficiency class
Power input total

(min)
(max)

Current input

(min)
(max)
Tipo

Compressor
Fans
(E.U.)
Airflow rate nominal (I.U.)
Sound pressure (I.U.)
Sound pressure (E.U.)

n
3
m /h
dB(A)
dB(A)
liquid
gas

Refrigerant connections

(Vmax)
(max)
(max)
inch
inch
inch
mm
inch
mm
m
m

liquid
Refrigerant lines
gas
Maximum refrigerant line lengths
Maximum elevation change

071
071C
7000
2400
8500
5,10
A
2180
850
2500
10,10
3,6
11,0
8000
2400
9500
3,8
A
2210
800
2750
10,20
3,40
12,0

086
086C
8300
2600
9200
5,10
A
2670
850
2700
12,4
3,6
11,8
9200
2400
9900
3,8
A
2570
800
2860
12,0
3,4
12,6

101
121
101C 121C
10000 11000
3200
3300
11500 12000
5,10
5,10
A
A
3200
3900
750
530
4500
4650
15
18,10
3,6
2,87
20,0
20,0
12000 12500
2900
3600
14500 15000
3,8
3,8
A
A
3500
3800
600
640
4800
4800
16,20 17,60
2,90
3,32
21,0
20,0
DC-Inverter

141
141CB
14000
6000
14800
5,10
A
4600
1300
5500
21,30
5,80
26,0
16000
5200
18000
3,8
A
4500
1200
5400
20,8
5,4
25,0

101T
101C
10000
3200
11500
5,10
A
3120
700
4700
5,40
1,20
8,20
12000
2900
14500
3,8
A
3320
600
4800
5,80
1,0
8,30

121T
121C
11000
3300
12000
5,10
A
3900
600
4700
6,70
1
8,20
12500
3600
15000
3,8
A
3800
640
4800
6,60
1,10
8,3

1
1860
51
63
3/8
5/8
9,52
3/8
16,0
5/8
30
15

2
1860
51
61
3/8
5/8
9,52
3/8
16,0
5/8
50
30

700
46
52
1/4
3/8
6,0
1/4
9,52
3/8
20
15

760
47
56
1/4
1/2
6,0
1/4
12,0
1/2
20
15

1300
47
57
3/8
5/8
9,52
3/8
16,0
5/8
30
15

1500
49
58
3/8
5/8
9,52
3/8
16,0
5/8
30
15

1860
51
63
3/8
5/8
9,52
3/8
16,0
5/8
30
15

1860
51
61
3/8
5/8
9,52
3/8
16,0
5/8
50
30

2300
53
59
3/8
5/8
9,52
3/8
16,0
5/8
50
30

Power supply internal unit (I.U.): 230V~50Hz

141T
141CB
14000
6000
14800
5,10
A
5150
1300
5500
8,90
2,20
9,50
16000
5200
18000
3,8
A
4500
1200
5400
7,80
2,0
9,3

161T
161CB
16000
6500
16500
5,10
A
5700
1300
6500
9,80
2,20
11,20
17000
5200
20000
3,8
A
4700
1200
6500
8,20
2,0
11,2

2300
53
59

2
2400
55
63

3/8
5/8

3/8
3/4"

9,52
3/8
16,0
5/8"
50
30

9,52
3/8
19,0
3/4"
50
30

Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T)

Sound pressure measured at 1m distance from front in semi-anechoic chamber


* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825

Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

5m

20C
7C db ; 6C wb
5m

Accessories
SUPPLY GRILLE: Supply grilles are motorised.
(600x600). Is a required accessory as the unit
shipped without.
Fitted with infrared receiver and emergency
LCI_CS is shipped without.
LCIGL40B: Supply and return air grille
operation button.
LCIGL40: Supply and return air grille (840x840).
(910x910). Is a required accessory as the unit
LCIGL40S: Supply and return air grilles
Is a required accessory as the unit LCI_C is
LCI_CB is shipped without.
Mod.
LCIGL40S
LCIGL40
LCIGL40B

LCI036CS

LCI051CS

LCI071C

LCI85C

LCI101C

LCI121C

LCI141CB

LCI161CB

Dimensional data (mm)


Mod.
A
B
C
Weight

A
B
C
Weight

LCI
mm
mm
mm
kg

036
540
848
320
34

LCI
mm
mm
mm
kg

051
700
955
396
47

071
790
980
427
67

086
790
980
427
71

101
1100
1107
440
92

036CS* 051CS** 071C**


600
600
840
600
600
840
240
240
240
20
20
26

*:Grille dimensions LCIGL40S mm 670x670x50; Weight = 5 kg


**:Grille dimensions LCIGL40 mm 950x950x60; Weight = 6,5 kg
***:Grille dimensions LCIGL40B mm 1040x1040x60;

121
1349
958
412
95

141
1349
958
412
105

086C**
840
840
320
31

101T
1100
1107
440
98

101C**
840
840
320
31

121T
1349
958
412
108

141T
1349
958
412
114

161T
1365
1085
427
126

LCI036
LCI051
C

LCI121
LCI121T
LCI141
LCI141T
LCI161T

LCI071
LCI086
LCI101

121C** 141CB*** 161CB***


840
910
910
840
910
910
320
290
290
31
43
43

B
A
C

439

Technical data
External Unit (E.U.) LCI
Internal Unit (I.U.) LCI
Cooling capacity

(min)
(max)

SEER
Energy efficiency class
Power input total

(min)
(max)

Current input

(min)
(max)

Heating capacity

(min)
(max)

Power input total

(min)
(max)

Current input

(min)
(max)
Type

SCOP
Energy efficiency class

Compressor
Fans
(E.U.)
Airflow rate nominal (I.U.)
Head nominal (I.U.)
Sound pressure (I.U.)
Sound pressure (E.U.)
Refrigerant connections

n
m3/h
Pa
dB(A)
dB(A)
liquid
gas
liquid

Refrigerant lines
gas
Maximum refrigerant line lengths
Maximum elevation change

(Vmax)
(Vmax)
(max)
(max)
inch
inch
mm
inch
mm
inch
m
m

026
026D
2700
800
3400
5,1
A

036
036D
3500
900
3900
5,1
A

051
051D
5000
1600
5800
5,1
A

071
071D
7000
2200
8500
5,1
A

086
086D
8300
2400
8700
5,1
A

101
101D
10000
3200
11500
5,1
A

121
121D
11500
3600
12500
A

141
141D
14000
6000
14500
5,1
A

840

1170

1550

2180

2670

3200

200
1280
3,90
1,00
6,00
2900
800
3700
3,8
A

200
1400
5,40
1,00
6,20
3800
900
4100
3,8
A

550
1750
7,50
2,30
7,80
5600
1400
6800
3,8
A

850
2500
10,10
3,60
11,00
8000
2400
9500
3,8
A

850
2700
12,40
3,60
11,80
9200
2400
9900
3,8
A

700
4500
15,00
4,00
21,00
12000
2900
14500
3,8
A

4000
650
4700

4700
1400
5600

18,60
3,89
20,00
13500
3900
15500
3,8
A

21,80
6,20
27,00
15500
5200
17000
3,8
A

800

1050

1550

2210

2570

3400

3900

4400

200
1200
3,70
1,00
5,40

220
1200
4,90
1,00
5,40

500
1900
7,40
2,10
8,40

800
2750
10,20
3,40
12,00

800
2860
12,00
3,40
12,60

700
760
4600
4750
15,50
18,10
3,00
4,32
21,00
20,00
DC-Inverter
1
2

1300
5500
20,40
5,80
26,00

1
650
25
36
52
1/4
3/8
6,35
1/4
9,52
3/8
20
15

5,1

101T
101D
10000
3200
11500
5,1
A
3120
850
4600
5,40
1,40
8,00
12000
2900
14500
3,8
A
3320
650
4800
5,80
1,10
8,30

121T
121D
11500
3600
12500
5,1
A
4000
700
4800
6,90
1,20
8,30
13500
3900
15500
3,8
A
3900
760
4750
6,70
1,30
8,30

141T
141D
14000
6000
14500
5,1
A
5100
1400
5600
8,80
2,40
9,70
15500
5200
17000
3,8
A
4500
1300
5500
7,80
2,20
9,50

161T
161D
16000
6800
17500
5,1
A
5600
1400
6600
9,70
2,40
11,40
16500
5300
18800
3,8
A
4570
1300
6400
7,90
2,20
11,00

1
2100

2
2100

2
2400

37
53

37
53

50
55
59
3/8
5/8
9,52
3/8
15,9
5/8
50
30

2
3000
50
57
63
3/8
3/4"
9,52
3/8
19
3/4
50
30

750
25
37

1000
25
40

1400
25
47

1400
37
47

2100
37
53

2100
37
53

2400
50
55

52
1/4
3/8
6,35
1/4
9,52
3/8

56
1/4
1/2
6,35
1/4
12,7
1/2

57
3/8
5/8
9,52
3/8
15,9
5/8

58
3/8
5/8
9,52
3/8
15,9
5/8

63
3/8
5/8
9,52
3/8
15,9
5/8

61
3/8
5/8
9,52
3/8
15,9
5/8

59
3/8
5/8
9,52
3/8
15,9
5/8

63
3/8
5/8
9,52
3/8
15,9
5/8

61
3/8
5/8
9,52
3/8
15,9
5/8

20
15

20
15

30
15

30
15

50
15

50
30

50
30

50
15

50
30

Power supply Internal Unit (I.U.): 230V~50Hz (LCI_D)


Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T)
Sound pressure measured at 1m distance from front in semi-anechoic chamber
* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825
Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

5m

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

20C
7C db ; 6C wb
5m

Dimensional data (mm)


Mod.
A
B
C
Weight

LCI
mm
mm
mm
kg

026
540
848
320
34

036
540
848
320
34

051
700
955
396
47

071
790
980
427
67

086
790
980
427
71

101
1100
1107
440
92
B

121
1349
958
412
95

101T
1100
1107
440
98

121T
1349
958
412
108

141T
1349
958
412
114

161T
1365
1085
427
126

C
LCI121
LCI121T
LCI141
LCI141T
LCI161T

141
1349
958
412
105

A
C
B

LCI026
LCI036
LCI051

LCI071
LCI086
LCI101

Mod.
A
B
C
Weight

440

LCI
mm
mm
mm
kg

026D
250
925
665
27

036D
266
1037
721
33

051D
266
1037
721
33

071D
268
1279
558
34

086D
268
1279
558
34

101D
290
1226
775
46

121D
290
1226
775
46

141D
350
1340
750
56

161D
350
1340
750
57

Technical data
External Unit (E.U.) LCI
Internal Unit (I.U.) LCI

026
026F

036
036F

051
051F

071
071F

086
086F

101
101F

121
121F

141
141F

101T
101F

141T
141F

161T
161F

3500
900
3900
5,1
A
1090
260
1400
5,00
1,10
6,20
3800
900
4100
3,8
A
1050
220
1200
4,90
1,00
5,40

5000
1600
5800
5,1
A
1550
550
1750
7,20
2,30
7,80
5600
1400
6800
3,8
A
1550
500
1900
7,20
2,10
8,40

7000
2400
8200
5,1
A
2180
850
2500
10,10
3,60
11,00
8000
2400
9000
3,8
A
2210
800
2750
10,20
3,40
12,00

8500
2600
9200
5,1
A
2670
850
2700
12,40
3,60
11,80
9200
2400
9900
3,8
A
2570
800
2860
12,00
3,40
12,60

10000
3200
11500
5,1
A
3200
800
4600
15,00
4,00
20,00
12000
2900
14500
3,8
A
3400
650
4800
15,80
3,50
21,00

11500
3600
12500
5,1
A
3900
600
4700
18,10
3,36
20,00
13500
3900
15500
3,8
A
3700
690
4800
17,20
3,80
20,00

14000
6000
14800
5,1
A
4800
1400
5600
22,30
6,20
27,00
16000
5200
18000
3,8
A
4300
1300
5500
20,00
5,80
26,00

10000 11500 14000


3200
3600
6000
11500 12500 14800
5,1
5,1
5,1
A
A
A
3120
3900
5000
750
600
1400
4700
4750
5600
5,40
6,70
8,60
1,30
1,00
2,40
8,20
8,20
9,70
12000 13500 16000
2900
3900
5200
14500 15500 18000

16000
6350
16500

1
700
35
52
1/4
3/8
6,35
1/4
9,52
3/8

1
1000
44
56
1/4
1/2
6,35
1/4
12,7
1/2

1
1200
49
57
3/8
5/8
9,52
3/8
15,9
5/8

1
1500
49
58
3/8
5/8
9,52
3/8
15,9
5/8

1
1900
54
63
3/8
5/8
9,52
3/8
15,9
5/8

2
1900
55
61
3/8
5/8
9,52
3/8
15,9
5/8

20
15

20
15

30
15

30
15

50
15

50
30

Power input total

(min)
(max)

Current input

(min)
(max)

2700
800
3500
5,1
A
840
200
1280
3,90
1,00
6,00
2900
800
3800
3,8
A
800
200
1200
3,70
1,00
5,40

Compressor
Fans
(E.U.)
Airflow rate nominal (I.U.)
Sound pressure (I.U.)
Sound pressure (E.U.)

Type
n
m3/h
dB(A)
dB(A)
liquid
gas

(Vmax)
(max)
(max)
inch
inch
mm
inch
mm
inch
m
m

1
600
31
52
1/4
3/8
6,35
1/4
9,52
3/8
20
15

Cooling capacity

(min)
(max)

SEER
Energy efficiency class
Power input total

(min)
(max)

Current input

(min)
(max)

Heating capacity

(min)
(max)

SCOP
Energy efficiency class

Refrigerant connections

liquid
Refrigerant lines
gas
Maximum refrigerant line lengths
Maximum elevation change

121T
121F

5,1
A
5750
1400
6600
10,00
2,40
11,40
17000
5500
20000

3,8

3,8

3,8

3,8

A
3320
600
4800
5,80
1,00
8,30

A
3740
690
4800
6,50
1,20
8,30

A
4500
1300
5500
7,80
2,20
9,50

A
4700
1300
6500
8,20
2,20
11,20

2
2300
57
59
3/8
5/8
9,52
3/8
15,9
5/8

1
1900
54
63
3/8
5/8
9,52
3/8
15,9
5/8

2
1900
55
61
3/8
5/8
9,52
3/8
15,9
5/8

50
30

50
15

50
30

2
2300
57
59
3/8
5/8
9,52
3/8
15,9
5/8
50
30

2
2500
58
63
3/8
3/4
9,52
3/8
19
3/4
50
30

DC-Inverter

Power supply Internal Unit (I.U.): 230V~50Hz (LCI_F)


Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T)
Sound pressure measured at 1m distance from front in semi-anechoic chamber
* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825
Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

5m

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

20C
7C db ; 6C wb
5m

Dimensional data (mm)


LCI
mm
mm
mm
kg

026
540
848
320
34

036
540
848
320
34

051
700
955
396
47

071
790
980
427
67

086
790
980
427
71

101
1100
1107
440
92

121
1349
958
412
95

B
C

LCI026
LCI036
LCI051

101T
1100
1107
440
98

121T
1349
958
412
108

141T
1349
958
412
114

161T
1365
1085
427
126

C
LCI121
LCI121T
LCI141
LCI141T
LCI161T

141
1349
958
412
105

LCI071
LCI086
LCI101

Mod.
A
B
C
Weight
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

LCI
mm
mm
mm
kg

026F
700
1220
225
38

036F
700
1220
225
39

051F
700
1220
225
39

071F
700
1220
225
40

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

086F
700
1420
245
48

101F
700
1420
245
48

121F
700
1420
245
50

141F
700
1700
245
59

161F
700
1700
245
59

441

Cod.: SLCIUI.03 / 1503

Mod.
A
B
C
Weight

DXE

Reversible heat pump for light commercial applications


Ducted horizontal installation with power from 20 up to 39,5 kW

DXE 20E

DXE 25E

DXE 30E

DXE 40E

Wired control
panel

DXE 20CT
DXE 25CT

Remote control

DXE 30CT

DXE 40CT

Features

R410A refrigerant gas


Indoor unit (DXE E):
Heat Pump
Ducted unit for horizontal installation
Auto-Restart (function can be deactivated)
The units have two air probes: one on the wired
Condensate control device for functioning in
control panel and one on the internal unit
cooling mode with external temperature to
return. Can be selected from the wired panel
-15C, as per standard
Metal cabinet in galvanised sheet steel
Double intake centrifugal fans single speed
Regenerative air filter
Infrared ray remote control with liquid crystal
display wired control panel for checking all functions
Liquid crystal display wired control panel for
checking all functions, infrared receiver and
environment temperature probe
Microprocessor control

442

Outdoor unit (DXE CT):


Metal protection cabinet with anti-corrosion
paint
Heat exchange coil in copper piping with aluminium louvers
Helical fan coupled directly to the electric
motor
The maximum length of the chiller lines is 50 m
and maximum difference in level 30 m

Technical data
DXE
DXE
Cooling capacity

kW
kW
A
kW
kW
A
V-Ph-Hz
V-Ph-Hz
m3/h
Pa
dB (A)
dB (A)
kg
g/m
(gas)
(liquid)
(gas)
(liquid)

Total input power


Maximum total current
Heating capacity
Total input power
Maximum total current
Power supply (outdoor unit)
Power supply (indoor unit)
Indoor unit air flow rate
Useful static pressures
Sound pressure (indoor unit)
Sound pressure (outdoor unit)
Refrigerant gas load (R410A)
* Refrigerant gas top-up
Refrigerant lines
Refrigerant fittings

20 CT
20 E
20
8,4
15,3
22
7
13,2

25 CT
25 E
24,5
9,8
22,2
27,5
9
21,2

30 CT
30 E
30
12,5
27
33
10,5
23

40 CT
40 E
39,5
13,6
37,8
42
11,8
34

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

400V 3N 50Hz

4000
220
65
65
5,3*
54
3/4(19,05)
3/8(9,52)
3/4(19,05)
3/8(9,52)

4800
110
54
64
6,7*
54
1(25,4)
3/8(9,52)
1(25,4)
3/8(9,52)

5500
120
54
67
9,5
120
9/8(28,6)
1/2(12,7)
9/8(28,6)
1/2(12,7)

7000
150
58
69
12*
170
9/8(28,6)
5/8(15,9))
9/8(28,6)
5/8(15,9)

The performance refers to the following conditions:


Sound pressure measures in a semianechoic chamber, under the unit, at
r=1,4m
Sound pressure measures in a semianechoic chamber at 1m from the
front
* =for lines up to 7.5m; over perform top-up
Cooling:
- Room air temperature 27C D.B. ; 19C W.B.
- External air temperature 35C

Heating:
- Environmental air temperature 20C
- External air temperature 7C D.B. ; 6C W.B.

Dimensional data (mm)


INDOOR UNIT

DXE 25E

DXE 20E

DXE 40E

DXE 30E

OUTDOOR UNIT

Height
Width
Depth
Weight

A
B
C
kg

20 E
389
1463
799
86

25 E
500
1745
1116
150

DXE 30CT

DXE
30 E
500
1745
1116
170

40 E
650
1700
1100
215

20 CT
1350
1150
460
158

25 CT
1600
1150
460
185

DXE
30 CT
1772
990
880
218

DXE 40CT

Cod.: SDXEUY.06 / 0211

DXE 20CT
DXE 25CT

40CT
1772
1290
800
285

Maximum clearance
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

443

EWIH

Split system heat pumps


Wall installation with capacities from 2,6 up to 7,0 kW with Inverter and
Plasmacluster filter

R410A
EWI 091 H
EWI 121 H

Seasonal Energy Efficiency


See Technical data

Plasmacluster

EWI 182 H
EWI 242 H

CWI H

PLASMACLUSTER ionising filter.


Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions
neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
EWIH is fitted with a new generation filter: PLASMACLUSTER produces even more ions than the previous version.
The result is faster air purification in the climate controlled environment.
The COANDA effect
EWIH is fitted with new vertical deflectors which, in addition to the standard positions used in cooling and heating mode, can also direct the air flow
towards the ceiling (cooling function) or towards the floor (heating function).
The result is better air distribution around the room without irritating draughts

Features
With R410A refrigerant
Available in 4 different power versions
Inverter technology for large power savings
and optimized room comfort conditions
Room reaches required temperature after
switching on in 2/3 the time of an equivalent
appliance without an inverter
Excellent ratio between heating capacity and
cooling capacity, thanks to the inverter-controlled compressor
Three-speed cross flow fan
Variable speed rotary compressor
Air outlet deflectors with horizontal

444

adjustment facility
Motorized louver controllable from remote
handset for vertical adjustment of outlet air
flow direction
Very quiet operation
Infrared remote handset with LCD display for
full control of all functions of the appliance
Microprocessor control
Local control facility
Timer for programming On/Off times
Programs for cooling only, heating only,
dehumidification and automatic operation
(heating/cooling)

Self-diagnostics function
Easily removable, washable air filter with
anti-mould treatment
Defrost control

Condensation control device for operation in cooling mode with an external


temperature up to -10C
Refrigerant lines with flared ends
Refrigerant lines up to 15m for (091H 121H), up to 20m for (EWI 182H) and up to
30m for(EWI 242H)

Technical data

Cooling capacity

nominal
min. - max.

W
W

nominal
min. - max.
nominal
max. speed
max.
med.
min.
nominale
min. - max.

W/W
W
W
A
l/h
m3/h
m3/h
m3/h
W
W

6,3
780
200 - 960
3,7
0,7
516
438
330
3100
900 - 4800
A+

nominale
min. - max.
nominale

W/W
W
W
A

4,3
730
160 - 1400
3,5

Energy Efficiency
SEER
Input power
Input current

Moisture removed
Indoor unit air flow rate

Heating capacity

Energy Efficiency
SCOP
Input power
Input current
Power supply

Indoor unit

Sound pressure

outdoor unit
Outdoor unit air flow rate
Refrigerant connections

EWI 091 H
CWI 091 H
2640
900 - 3000
A++

liquid
gas

max. dB (A)
min. dB (A)
dB (A)
m3/h

Performance values refer to the following conditions:


measured at 1.3m in an anechoic chamber.
Cooling:
- room air temperature 27C D.B., 19C W.B.;
- ambient air temperature 35C; maximum speed.

39
28
45
1398
1/4
3/8

EWI 121 H
EWI 182 H
CWI 121 H
CWI 182 H
3500
5000
1400 - 5700
900 - 3800
A
A++
6,7
5,4
1470
1090
260 - 1890
210 - 1300
6,6
5,0
1,6
1,2
864
588
726
510
570
414
5700
4000
1100 - 8000
1000 - 6000
A
A
3,8
3,9
1510
1030
240 - 2380
180 - 1900
6,8
4,8
230V ~ 50Hz
43
40
39
28
49
48
2658
1602
1/4
1/4
3/8
1/2

EWI 242 H
CWI 242 H
7000
1500 - 8000
A+
5,9
2160
260 - 2990
9,6
2,6
1104
864
642
7500
1100 - 9500
A+
4,0
2015
240 - 2830
8,9
47
42
53
2736
1/4
5/8

Heating:
- room air temperature 20C;
- ambient air temp. 7C D.B., 6C W.B.; max. speed

Dimensions (mm)

OUTDOOR UNIT

INDOOR UNIT

EWI 091 H
EWI 121 H

EWI 182 H
EWI 242 H

INDOOR UNIT

Height
Width
Depth
Weight

A
B
C
kg

EWI 091 H
278
790
198
10

EWI 121 H
278
790
198
10

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

EWI 182 H
325
1040
222
12

EWI 242 H
325
1040
222
13

CWI 091 H
540
730
250
36

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293577
www.aermec.com

CWI 121 H
540
730
250
36

CWI 182 H
710
850
330
49

CWI 242 H
710
850
330
53

445

Cod.: SEWIHUY.11 / 1502

CWI 091 H
CWI 121 H
CWI 182 H
CWI 242 H

EFSI

Split system heat pumps


Floor installation with capacities from 2.5 up to 5 kW with Inverter and
Plasmacluster filter
HE

AT
IN
G
OU
O
TS
ID PERA
TIO
DO E TE
N
WN MP
WI
TH
TO ERAT
U
-15
RE
C

R410A

Seasonal Energy Efficiency


See Technical data

Plasmacluster

PLASMACLUSTER ionising filter


Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions
neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.

Features

With R410A refrigerant gas


Available in 3 versions of different capacities
Vertical, free-standing installation
Elegant design and compact size
Plasmacluster air purifier
Inverter technology for large power savings
and optimised room comfort conditions
Following ignition, the required temperature
is reached in 2/3 of the time taken by an air
conditioning system without Inverter
High heating capacity - cooling capacity
ratio, thanks to the Inverter
Variable speed rotary compressor
Double delivery, with air outlet fins in both

446

the lower and upper parts, for better air distribution and to minimise temperature differences at different heights
Air distribution differentiated between cooling and heating mode, to obtain the maximum comfort
Microprocessor control
Infrared remote control with liquid crystal
screen for controlling all the functions
Timer for programming on/off times
Operation modes: Cooling, Heating,
Dehumidification and Automatic
Auto-restart
Self-diagnostics function

Particularly quiet operation


Regenerable air filter
Refrigerant lines with flared ends
Ease of installation and maintenance
Condensation control device for cooling
mode with outside temperatures down to
-10C
Heating mode with outside temperatures
down to -15C

Technical data
EFSI 090 H

EFSI 120 H

CFSI 090 H
2500
900 - 3000
A
4,07
615

CFSI 120 H
3500
900 - 4000
A
3,26
1075

W (min. - max.)

200 - 890

230 - 1320

A (nominal)
A (min. - max.)
l/h
m3/h (min)
m3/h (med)
m3/h (max)
dB (A)
W (nominal)
W (min. - max.)

2,9
1,0 - 4,0
0,4
276
444
594
45
3400
900 - 5000
A
4,36
780
200 - 1400
3,6
1,0 - 6,3
342
480
612
46
22
29
37

5,0
1,1 - 6,0
0,95
300
498
630
46
4500
900 - 6000
A
3,66
1230
230 - 1730
5,7
1,1 - 7,7
366
510
660
47
23
31
38

W (nominal)
W (min. - max.)

Cooling capacity
Energy Efficiency Cooling Mode
SEER

W (nominal)

Total input power


Total input current
Humidity removed
Air flow rate (EFSI)
** Sound pressure (CFSI - CWI)
Heating capacity
Energy Effinciency Heating Mode
SCOP

W (nominal)
W (min. - max.)
A (nominal)
W (min. - max.)
m3/h (max)
m3/h (max)
m3/h (max)
dB (A)
dB (A) (min)
dB (A) (med)
dB (A) (max)

Total input power


Total input current

Air flow rate (EFSI)


* Sound Pressure (CFSI - CWI)
Sound Pressure (EFSI)
Line max lenghts

m (max)

20

20

Max level difference

m (max)
liquid
max

7
1/4
3/8

7
1/4
3/8

Refrigerant connections

Electric power supply = 230V ~ 50Hz


Performance values refer to the following conditions:
* measured in anechoic chamber at 1.3m from front, direction factor 4
** measured in anechoic chamber at 1m from front, direction factor 2
-

Cooling:
Room air temperature 27C B.S. ; 19C B.U.
Ambient air temperature 35C
Maximum Speed
Refrigerant lines lenght 5m

Heating:
Room air temperature 20C
Ambient air temp. 7C B.S. ; 6C B.U.
Maximun speed
Refrigerant lines length 5m

Dimensions (mm)

EFSI
EFSI
Height
Width
Depth
Weight

A
B
C
kg

090 H
670
750
235
17

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

120 H
670
750
235
17
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

CFSI
090 H
540
730
250
33

Cod.: SEFSIUY.03 / 1503

CFSI_H
CWI_H
CFSI
120 H
540
730
250
33

447

MKM

Multisplit system heat pump


Inverter MultiSplit System with capacity from 5 to 12kW
Wall mounted unit with air ioniser standard

x1

R410A

x2

MKM_WS

x3

Controller
MKM_W

Seasonal Energy Efficiency


See Technical data

x4
x5

MKM_F

Controller

= MKM_W
MKM_WS
MKM_C
MKM_CS
MKM_D
MKM_F

Wired panel

MKM_C
MKM_CS

MKM_D

MKM

Characteristics
Dualsplit:
External units MKM42-52-72 connected to 1
or 2 internal units
Trisplit:
External unit MKM73 connected to 2 or 3
internal units
Quadrisplit:
External units MKM84 and MKM104 connected to 2, 3 or 4 internal units
Pentasplit:
External unit MKM125 connected to 3, 4 or 5
internal units
Internal unit choices from:
Wall (Wall mounted)
with remote controller:
MKM 20W - 25W - 35W - 50W
MKM 20WS - 25WS - 35WS - 50WS
Cassette 600x600 (False ceiling mounted)
with remote controller and wired panel:
MKM35CS - 50CS
(it is required to connect with accessory
MKMGL40S)
Cassette 840x840 (False ceiling mounted)
with remote controller and wired panel:
MKM35C - 50C - 70C
(it is required to connect with accessory
MKMGL40)

448

Floor Ceiling (Wall or ceiling mounted)


with remote controller and wired panel:
MKM25F - 35F - 50F - 70F
Ducted (Horizontal installation)
with remote controller and wired panel:
MKM25D - 35D - 50D - 60D - 70D
Nominal head 10Pa (450m3/h)
Refrigerant R410A
DC Inverter rotary compressor for higher
energy savings and for optimised ambient
conditions
Internal unit with three speed fan
External unit multi-speed single fan
Rotary compressor with variable speed
Horizontally adjustable air discharge louvres
(MKM_W, MKM_WS, MKM_C, MKM_CS,
MKM_F)
Motorised deflector louvres for vertical
adjustment of discharge air (MKM_W, MKM_
WS, MKM_C, MKM_CS, MKM_F)
Air ioniser standard for wall mounted units
(MKM_W, MKM_WS)
Extremely low noise operation
Infrared remote controller with liquid crystal
display to control all functions
Wired panel with liquid crystal display and
Soft Touch buttons to control all functions
(MKM_C, MKM_CS, MKM_D, MKM_F)

Microprocessor control
Possibility to set the ambient temperature sensor in the intake of the internal unit or in the
wired panel (MKM_C, MKM_CS, MKM_D,
MKM_F)
Timer for programming switch on and/or off
Operating modes: Cooling, Heating,
Dehumidication, Automatic or Ventilation
Only
Auto-diagnostic function
Air filter easily removed and cleaned
Efficient defrost control
Condensate discharge pump standard in versions MKM_CS, MKM_C and MKM_D
Flare type refrigerant connections
Multi-line refrigerant connection system,
where each internal unit is connected to the
external unit through dedicated refrigerant
lines
Total refrigerant line length:
up to 20m for the external units MKM52 and
MKM72
up to 70m for the external units MKM73,
MKM84 and MKM104
up to 80m for the external unit MKM125

Accessories
MKMGL40S: (600x600)
MKMGL40: (840x840)
Supply and return air grille. Supply grilles are
Mod.
MKMGL40S
MKMGL40

motorised. Fitted with infrared receiver and


emergency operation button.
Is a required accessory as the units MKM_C

MKM35CS

MKM50CS

and MKM_CS are shipped without.

MKM35C

MKM50C

MKM70C

Combination of internal units permitted


internal unit MKM_C - MKM_CS - MKM_D - MKM_F - MKM_W - MKM_WS:
External unit Dualsplit MKM42 (14kBtu/h)
Totale (k)
Unit A
Unit B
7
20 (7k)
9
25 (9k)
12
35 (12k)
14
20 (7k)
20 (7k)
16
20 (7k)
25 (9k)
18
25 (9k)
25 (9k)
19
20 (7k)
35 (12k)
21
25 (9k)
35 (12k)

Total (k)
14
16
18
19
21
24
25
27
30
36
21
23

Total (k)
14
16
18
19
21
24
25
27
30
36
21
23
25
26
27
28
30
31
32
33

Unit A
20 (7k)
20 (7k)
25 (9k)
20 (7k)
25 (9k)
35 (12k)
20 (7k)
25 (9k)
35 (12k)
50 (18k)
20 (7k)
20 (7k)

Unit A
20 (7k)
20 (7k)
25 (9k)
20 (7k)
25 (9k)
35 (12k)
20 (7k)
25 (9k)
35 (12k)
50 (18k)
20 (7k)
20 (7k)
20 (7k)
20 (7k)
25 (9k)
20 (7k)
25 (9k)
20 (7k)
20 (7k)
25 (9k)

Dualsplit: possible installation of 1 or 2 internal units


External unit Dualsplit MKM52 (18kBtu/h)
External unit Dualsplit MKM72 (24kBtu/h)
Totale (k)
Unit A
Unit B
Totale (k)
Unit A
Unit B
7
20 (7k)
14
20 (7k)
20 (7k)
9
25 (9k)
16
20 (7k)
25 (9k)
12
35 (12k)
18
25 (9k)
25 (9k)
14
20 (7k)
20 (7k)
19
20 (7k)
35 (12k)
16
20 (7k)
25 (9k)
21
25 (9k)
35 (12k)

18

25 (9k)

25 (9k)

24

35 (12k)

35 (12k)

19
21

20 (7k)
25 (9k)

35 (12k)
35 (12k)

25
27
30

20 (7k)
25 (9k)
35 (12k)

50 (18k)
50 (18k)
50 (18k)

Trisplit: it is required to install at least 2 internal units for correct system operation
External unit Trisplit MKM73 (24k)
Unit B
Unit C
Total (k)
Unit A
20 (7k)
25
20 (7k)
25 (9k)
26
20 (7k)
25 (9k)
27
25 (9k)
35 (12k)
28
20 (7k)
35 (12k)
30
25 (9k)
35 (12k)
31
20 (7k)
50 (18k)
32
20 (7k)
50 (18k)
33
25 (9k)
50 (18k)
34
20 (7k)
50 (18k)
36
25 (9k)
20 (7k)
20 (7k)
36
35 (12k)
20 (7k)
25 (9k)

Unit B

Unit C

25 (9k)

25 (9k)

20 (7k)
25 (9k)
25 (9k)
25 (9k)
35 (12k)
20 (7k)
35 (12k)
25 (9k)
25 (9k)
35 (12k)

35 (12k)
25 (9k)
35 (12k)
35 (12k)
35 (12k)
50 (18k)
35 (12k)
50 (18k)
50 (18k)
35 (12k)

Quadrisplit: it is required to install at least 2 internal units for correct system operation
External unit Quadrisplit MKM84 (28k)
Unit B
Unit C
Unit D
Total (k)
Unit A
Unit B
20 (7k)
34
20 (7k)
25 (9k)
(25 (9k)
36
25 (9k)
25 (9k)
25 (9k)
36
35 (12k)
35 (12k)
35 (12k)
37
20 (7k)
35 (12k)
35 (12k)
39
25 (9k)
35 (12k)
35 (12k)
42
35 (12k)
35 (12k)
50 (18k)
28
20 (7k)
20 (7k)
50 (18k)
30
20 (7k)
20 (7k)
50 (18k)
32
20 (7k)
20 (7k)
50 (18k)
33
20 (7k)
20 (7k)
20 (7k)
20 (7k)
34
20 (7k)
25 (9k)
20 (7k)
25 (9k)
35
20 (7k)
20 (7k)
25 (9k)
25 (9k)
36
25 (9k)
25 (9k)
20 (7k)
35 (12k)
37
20 (7k)
25 (9k)
25 (9k)
25 (9k)
38
20 (7k)
20 (7k)
25 (9k)
35 (12k)
39
20 (7k)
20 (7k)
25 (9k)
35 (12k)
39
25 (9k)
25 (9k)
35 (12k)
35 (12k)
40
20 (7k)
25 (9k)
20 (7k)
50 (18k)
41
20 (7k)
20 (7k)
35 (12k)
35 (12k)
42
25 (9k)
25 (9k)
External unit Quadrisplit MKM104 (36k)

Unit C
50 (18k)
50 (18k)
35 (12k)
50 (18k)
50 (18k)
50 (18k)

Unit D
-

20 (7k)

20 (7k)

20 (7k)
25 (9k)
20 (7k)
25 (9k)
25 (9k)
25 (9k)
25 (9k)
35 (12k)
20 (7k)
25 (9k)
35 (12k)
25 (9k)
35 (12k)

25 (9k)
25 (9k)
35 (12k)
25 (9k)
35 (12k)
25 (9k)
35 (12k)
35 (12k)
50 (18k)
35 (12k)
35 (12k)
50 (18k)
35 (12k)

Total connectable power of the external unit between 50% and 150% of its nominal power (36k)
Pentasplit: it is required to install at least 3 internal units for correct system operation
External unit Pentasplit MKM125 (42k)
Total connectable power of the external unit between 50% and 150% of its nominal power (42k)

449

Technical data
External Unit
Cooling capacity

(min)
(max)

Power input

(min)
(max)

Heating capacity

(min)
(max)

Power input

(min)
(max)

SEER
Energy efficiency class

SCOP
Energy efficiency class
Power input nominal*
Compressor
Sound pressure
Max number of connected units
Power supply

W
dB(A)
n.

MKM42
4100
2050
4500
1200
500
1500
5,6
A+
4500
2500
5000
1150
580
1500
3,8
A
1500

MKM52
5000
2050
6200
1550
500
2550
5,6
A+
5600
2500
6650
1550
580
2700
3,8
A
2700

MKM72
7000
2200
10000
2460
650
4550
5,8
A
7700
3600
11000
2560
980
3950
3,8
A
4550

55
2

57
2

58
2

MKM73
MKM84
7100
8000
2200
2200
10000
10000
2250
2490
650
650
4550
4550
5,1
5,1
A
A
8500
9300
3600
2880
11000
11000
2350
2580
980
980
3950
3950
3,8
3,8
A
A
4550
4550
Rotary DC Inverter
58
59
3
4

MKM104
10000
2100
11000
3750
700
3900
5,1
A
11000
2600
13000
3800
1300
3900
3,8
A
4880

MKM125
12100
3500
13600
3590
1300
4900
13000
4500
14000
3540
1300
4400
5300

54
4

54
5

230V ~ 50Hz

Sound pressure measured at 1m distance from front in semi-anechoic chamber


* In accordance with Standard EN-60335
Performances in accordance with Standards EN-14511 and EN-14825
-

Cooling:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

27C db ; 19C wb
35C

5m

MKM72

MKM73

Heating:
Ambient air temperature
External air temperature
Maximum speed
Refrigerant line length

EXTERNAL UNIT
MKM84

20C
7C db ; 6C wb
5m

MKM104

MKM125

with adaptor 1

9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 6,35 (1/4") 9,52 (3/8") 6,35 (1/4") 9,52 (3/8")

with adaptor 2

9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 6,35 (1/4") 6,35 (1/4") 9,52 (3/8")

with adaptor 3

9,52 (3/8") 12,7 (1/2")

9,52 (3/8") 6,35 (1/4")

with adaptor 4

9,52 (3/8") 12,7 (1/2")

9,52 (3/8") 12,7 (1/2")

with adaptor 5

12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8")

with adaptor 6

12,7 (1/2") 15,9 (5/8") 12,7 (1/2") 9,52 (3/8")

with adaptor 7

15,9 (5/8") 9,52 (3/8") 12,7 (1/2") 15,9 (5/8")

with adaptor 8

12,7 (1/2") 15,9 (5/8")

with adaptor 9

15,9 (5/8") 9,52 (3/8")

with adaptor 10

15,9 (5/8") 12,7 (1/2")

Model
Liquid connection / LINE
Gas connection / LINE
Model
Liquid connection / LINE
Gas connection / LINE
Model
Liquid connection / LINE
Gas connection / LINE
Model
Liquid connection / LINE
Gas connection / LINE
Model
Liquid connection / LINE
Gas connection / LINE
Model
Liquid connection / LINE
Gas connection / LINE

450

MKM20W
6,35 (1/4")
9,52 (3/8")
MKM20WS
6,35 (1/4")
9,52 (3/8")

INTERNAL UNIT - WALL


MKM25W
MKM35W
6,35 (1/4")
6,35 (1/4")
9,52 (3/8")
9,52 (3/8")
MKM25WS
MKM35WS
6,35 (1/4")
6,35 (1/4")
9,52 (3/8")
9,52 (3/8")
INTERNAL UNIT - DUCTED
MKM25D
MKM35D
6,35 (1/4")
6,35 (1/4")
9,52 (3/8")
9,52 (3/8")
INTERNAL UNIT - CASSETTE 600x600
MKM35CS
6,35 (1/4")
9,52 (3/8")
INTERNAL UNIT - CASSETTE 840x840
MKM35C
6,35 (1/4")
9,52 (3/8")
INTERNAL UNIT - FLOOR CEILING
MKM25F
MKM35F
6,35 (1/4")
6,35 (1/4")
9,52 (3/8")
9,52 (3/8")

MKM50W
6,35 (1/4")
12,7 (1/2")
MKM50WS
6,35 (1/4")
12,7 (1/2")
MKM50D
6,35 (1/4")
12,7 (1/2")

MKM60D
9,52 (3/8")
15,9 (5/8")

MKM70D
9,52 (3/8")
15,9 (5/8")

MKM50CS
6,35 (1/4")
12,7 (1/2")
MKM50C
6,35 (1/4")
12,7 (1/2")

MKM70C
9,52 (3/8")
15,9 (5/8")

MKM50F
6,35 (1/4")
12,7 (1/2")

MKM70F
9,52 (3/8")
15,9 (5/8")

Dimensional data (mm)

MKM_W

MKM_WS

MKM_C
MKMGL40
MKM_CS
MKMGL40S

MKM_D

MKM_F

MKM20W
MKM25W
MKM35W
MKM50W

A
(mm)
265
265
275
298

B
(mm)
794
794
845
945

C
(mm)
186
186
180
208

Weight
(kg)
9
9
10
13

MKM20WS
MKM25WS
MKM35WS
MKM50WS

283
283
283
305

770
770
770
865

201
201
201
215

8
8
9
12

MKM35CS*
MKM50CS*
MKMGL40S

230
230
50

600
600
650

600
600
650

18
18
5

MKM35C**
MKM50C**
MKM70C**
MKMGL40

190
190
240
50

840
840
840
950

840
840
840
950

25
25
30
5

MKM25D
MKM35D
MKM50D
MKM60D
MKM70D

200
200
200
200
200

782
782
982
1182
1182

635
635
635
635
635

22
24
25
29
29

MKM25F
MKM35F
MKM50F
MKM70F

700
700
700
700

1220
1220
1220
1220

225
225
225
225

40
40
40
45

MKM42
MKM52
MKM72
MKM73
MKM84
MKM104
MKM125

596
700
790
790
790
1103
1103

903
955
980
980
980
1087
1087

378
396
427
427
427
440
440

43
50
63
64
65
102
102

* Requires grille MKMGL40S (650x650mm)


** Requires grille MKMGL40 (950x950mm)
A

Aermec reserves the right to make all modifications deemed


necessary for improving the product at any time with any
modification of technical data.

Cod.: SMKMUY.04 / 1503

MKM

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

451

MIH

He
at
ing
op
e
er
Multisplit system heat pumps
xt
mo
a
e
tio
rn
de
MultiSplit System with capacities from 5.2 up to 8.4 kW with Inverter
al
n
do
w
t
wn emp ith
er
to
at
-1
5 ure
C

Plasmacluster
Seasonal Energy Efficiency
See Technical data

MIH E
MIHP071E
MIHP091E
MIHP121E

MVIH

x3
x4

MIHP181E

MDIH

= MIH E / MIHP E
MFIH / MVIH
MDIH E

MIH C

PLASMACLUSTER ionising filter (only for MIHP - MVIH).


Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions
neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.

Features
Available in 3 different power versions
Inverter technology for large power savings
and optimized room comfort conditions
Room reaches required temperature after
switching on in 2/3 the time of an equivalent
appliance without an inverter
Excellent ratio between heating capacity and
cooling capacity, thanks to the inverter-controlled compressor
Three speed cross-flow fan
Variable speed rotary compressor
Air outlet deflectors with horizontal adjustment
Optional indoor units among the following:
facility
MIH 071E - 091E - 121E
Motorized louver controllable from remote
MVIH 090E - 120E - 180E
handset for vertical adjustment of outlet air
MDIH 070E - 090E - 120E (must be combined
flow direction
with TL2I accessory)1)
Very quiet operation
MIHP 071E - 091E - 121E - 181E (with Infrared remote handset with LCD display for
Plasmacluster)
full control of all functions of the appliance
With R410A refrigerant
Microprocessor control
Trialsplit:
MIH 183C outdoor unit which can be connected
to 3 internal units
Quadrisplit:
MIH 244C outdoor unit which can be connected
to 4 indoor units
MIH 302C outdoor unit which can be connected to 4 indoor units, 180E/181E,
combined with outdoor unit MIH302C,
requires 3 indoor units instead of 4

452

Local control facility


Timer for programming On/Off times
Programs for cooling only, heating only, dehumidification and automatic operation (heating/
cooling)
Self-diagnostics function
Easily removable, washable air filter with
anti-mould treatmen
Defrost control
Refrigerant lines with flared ends
Refrigeration lines up to 20m for the internal
unit (max 50m for MIH 183C, max 50m for
MIH 244C, max 50m for MIH 302C)
Heating mode operation with external temperature down to -15 C

Technical data

Outdoor
Units

183C

244C

302C

Indoor Units*
MIH - MIHP - MVIH MDIH
09xE + 09xE + 09xE
12xE + 09xE + 07xE
12xE + 07xE + 07xE
09xE + 09xE + 07xE
09xE + 07xE + 07xE
07xE + 07xE + 07xE
09xE + 09xE + 09xE +09xE
12xE + 09xE + 07xE +07xE
09xE + 09xE + 09xE +07xE
12xE + 07xE + 07xE +07xE
09xE + 09xE + 07xE +07xE
09xE + 07xE + 07xE +07xE
07xE + 07xE + 07xE +07xE
18xE + 07xE + 07xE + /
18xE + 09xE + 07xE + /
18xE + 09xE + 09xE + /
18xE + 12xE + 07xE + /
07xE + 07xE + 07xE +07xE
07xE + 07xE + 07xE +09xE
07xE + 07xE + 09xE +09xE
07xE + 09xE + 09xE +09xE
09xE + 09xE + 09xE +09xE
07xE + 07xE + 07xE +12xE
07xE + 07xE + 09xE +12xE
07xE + 09xE + 09xE +12xE
07xE + 07xE + 12xE +12xE

Cooling capacity
Input power
nominal (min/max) nominal (min/max)
kW

kW

5,2 (2,2 / 7,2)


5,2 (2,2 / 7,2)
5,2 (2,2 / 7,2)
5,2 (2,2 / 7,2)
5,2 (2,2 / 7,2)
5,2 (2,2 / 7,0)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
7,0 (3,0 / 8,2)
8,3 (4,3 / 8,9)
8,3 (4,3 / 8,9)
8,3 (4,3 / 8,9)
8,3 (4,3 / 8,9)
8,0 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)
8,4 (4,3 / 9,0)

1,41 (0,43 / 2,56)


1,41 (0,43 / 2,56)
1,41 (0,43 / 2,56)
1,41 (0,43 / 2,56)
1,41 (0,43 / 2,56)
1,41 (0,43 / 2,46)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,18 (0,60 / 2,98)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,78 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)
2,99 (1,07 / 3,49)

**

A+

A++

SEER

6,0
6,2
5,2
-

Heating capacity
Input power
nominal (min/max) nominal (min/max)
kW

kW

6,8 (2,2 / 8,4)


6,8 (2,2 / 8,4)
6,8 (2,2 / 8,4)
6,8 (2,2 / 8,4)
6,8 (2,2 / 8,4)
6,8 (2,2 / 8,4)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,0 (3,0 / 9,2)
8,9 (4,4 / 10,5)
8,9 (4,4 / 10,5)
8,9 (4,4 / 10,5)
8,9 (4,4 / 10,5)
8,5 (4,4 / 9,8)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)
9,0 (4,4 / 10,6)

1,66 (0,42 / 2,48)


1,66 (0,42 / 2,48)
1,66 (0,42 / 2,48)
1,66 (0,42 / 2,48)
1,66 (0,42 / 2,48)
1,66 (0,42 / 2,48)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,00 (0,56 / 2,56)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,23 (0,94 / 2,85)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)
2,40 (0,94 / 3,06)

**

SCOP

4,1
4,3
3,9
-

A+

A+

Data refer to total power with all units running. The technical manual contains the efficiency data of each unit.
* = replace the x with 0 (zero) for MVIH - MDIH units and with 1 (one) for MIH E - MIHP E units.
** =Energy efficiency class
Trialsplit: It is necessary to install at least 2 indoor units to allow the system correct operation.
Quadrisplit: It is necessary to install at least 3 indoor units to allow the system correct operation.
The 18k indoor unit (MIHP181E o MVIH180E) can be matched with the MIH302C outdoor unit only. In this case the MIH302C outdoor unit can
be combined with max. 3 indoor units (see the recommended combinations)

Indoor Units
Air ow rate

Sound pressure

m3/h (max.)
m3/h (med.)
m3/h (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)

Indoor units
Air ow rate

Refrigerant
connections

m3/h (max.)
m3/h (med.)
m3/h (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)

Outdoor Units
Air ow rate
Sound pressure
Refrigerant connections

MIH
071E
480
444
330
37

MIHP
071E
480
444
330
37

28

28

MDIH
70
300
270
220
37,5
35,5
29,5

MVIH120E
666
534
405
40

MIH121E
588
510
414
40

MIHP121E
588
510
414
40

26

29

29

m3/h
dB (A)
liquid
gas

MVIH
090E
573
486
378
38

MIH
091E
516
474
330
39

MIHP
091E
516
474
330
39

25

28

28

MDHI120
520
410
320
36,5
32
26,5

MIH 183C
1980
46
1/4
3/8

MIH 244C
2580
49
1/4
3/8

MDIH
90
460
370
290
35
30
26

MVIH180E
864
714
531
44

MIHP181E
864

35

39

726
570

43

MIH 302C
3120
57
1/4
3/8

Power supply = 230V ~ 50Hz


Performance values refer to the following conditions:
measured at 1.3m in an anechoic chamber.
measured at 1m in an anechoic chamber.
Cooling
- room air temperature 27C D.B. ; 19C W.B.
- ambient air temperature 35C ; maximum speed

Heating:
- room air temperature 20C;
- ambient air temperature 7C D.B. ; 6C W.B. ; max.speed

453

Accessories
AMP
BC
DSC
GA
GAF
GM
MA
MU
PA

PC

PM
RD
RDA
RP
RPA
SE
TL
ZX

* = in combination with accessory MA

MDIH
4*
5**
8
4
22
32
42
22
32
42
22
32
42
22
32
42
22
32
42
22
32
42
22
23
32
33
42
43
22
32
42
22
32
42
22
32
42
22
32
42
22
32
42
20X
30X
40X
2 I ***
5
7

** =in combination with accessory MU

AMP: Kit for ceiling mounting.


BC: Auxiliary condensate drip tray.
DSC: Condensate drainage device for use
when natural run-off is not possible.
GA: Intake louver with fixed slats.
GAF: Intake louver with fixed slats and filter.
GM: Delivery louver with adjustable slats.
MA: Vertical cabinet.
MU: Universal cabinet.
PA: Intake plenum in galvanized steel, with

454

070

090

120

*** = It is a mandatory accessory because the units are consigned without MDIH

plastic outlet connections for circular section SE: Manually operated fresh air intake louver.
ducting.
TL2I: Infrared remote handset with LCD
PC: Rear cover panel.
display for full control of all appliance funPM: Delivery plenum in galvanized steel with
ctions. Kit including receiver for wall installaexternal insulation, with plastic outlet contion. (Obligatory accessory).
nections for circular section ducting.
ZX: Feet for floor standing installation of
RD: Delivery straight duct connection.
models with MA accessory; or built-in instalRDA: Intake straight duct connection.
lation.
RP: Delivery 90 duct connection.
RPA: Intake 90 duct connection.

Dimensions (mm)

MIH E

MIHP 181 E

MIHP 071 E
MIHP 091 E
MIHP 121 E

MIH C

MDIH
MVIH

Mod.
Height
Width
Depth
Weight

A
B
C
kg

MIH
071E
278
790
198
10

MIHP
071E
278
790
198
10

MVIH
090E
670
750
235
17

MIH
091E
278
790
198
10

MIHP
091E
278
790
198
10

A
B
C
kg

MVIH
180E
670
750
235
17

MIHP
181E
325
1040
229
16

MIH
183C
645
950
323
53

MIH
244C
800
950
357
64

MIH
302C
800
940
320
70

Mod.
Height
Width
Depth
Weight

MVIH
120E
670
750
235
17

MIH
121E
278
790
198
10

MIHP
121E
278
790
198
10

MDIH 070 - 090 - 120


070
457
592
216
440
453
41
101
74
260
144
49
522
17

090
457
823
216
671
453
41
101
74
260
144
49
753
23

120
457
1043
216
891
453
41
101
74
260
144
49
973
26

Cod.: SMIHUY.20 / 1310

MDIH
A
B
C
D
E
F
G
H
L
M
N
P
Weight [Kg]

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

455

MDW

Multisplit heat pumps with heat recovery


for hot domestic water production
Variable refrigerant flow system (VRF)
with inverter power input from 10 to 16 kW

Wired panel for MDW HB

MDW HB
HBi WT / WTS

MDW

Direct expansion indoor units

MDS WN

MDS F

MDS DH

Wired panel

Remote control

MDS C

MDS CS

Features
RNY01 or RNY11: Y-branch. The accessory is
composed of two Y-branches, one for the
liquid line and one for the discharge line.
Mandatory accessory
MDW HB: hydronic module for the production of hot water. Internal installation with
5kW or 8kW power
Mandatory accessory
HBi WT: HBI_WT: 200, 300, 350, 400 litre
DHW Storage Tank with main coil and 3kW
electric support resistance
- Magnesium sacrificial anode
- Stainless steel tank and coil
- Outdoor covering in painted sheet steel and
heat insulation material, thickness 50mm
-Indoor installation
Mandatory accessory (as an alternative to

HBi WTS)
HBi_WTS: 200, 300, 350, 400 litre DHW
Storage Tank with main coil, integrative coil
and 3kW electric support resistance
- Magnesium sacrificial anode
- Stainless steel tank and coil
- Outdoor covering in painted sheet steel and
heat insulation material, thickness 50mm
- Indoor installation
Mandatory accessory (as an alternative to
HBi WT)
MDSGL40S: air delivery and recovery grille
for internal Cassette-type units
Mandatory accessory for MDS CS
MDSGL40: air delivery and recovery grille
for internal Cassette-type units
Mandatory accessory for MDS C

ECD: remote contact kit. Allows the direct


expansion indoor units to be switched on/off
via an external contact
MDSCC1: centralised command for handling
up to 64 communication modules (MDSCM1
accessory), for a maximum of 64 outdoor
units
MDSCM1: communication module
MDSRC: simplified control panel for centralised command. Allows the direct expansion
indoor units to be controlled either individually or in groups
MDSR: signal repeater. Necessary if the communication cables are more than 1000
metres long

HBi WTS)
HBi_WTS: 200, 300, 350, 400 litre DHW
Storage Tank with main coil, integrative coil
and 3kW electric support resistance
- Magnesium sacrificial anode
- Stainless steel tank and coil
- Outdoor covering in painted sheet steel and
heat insulation material, thickness 50mm
- Indoor installation
Mandatory accessory (as an alternative to
HBi WT)
MDSGL40S: air delivery and recovery grille
for internal Cassette-type units
Mandatory accessory for MDS CS
MDSGL40: air delivery and recovery grille
for internal Cassette-type units
Mandatory accessory for MDS C

ECD: remote contact kit. Allows the direct


expansion indoor units to be switched on/off
via an external contact
MDSCC1: centralised command for handling
up to 64 communication modules (MDSCM1
accessory), for a maximum of 64 outdoor
units
MDSCM1: communication module
MDSRC: simplified control panel for centralised command. Allows the direct expansion
indoor units to be controlled either individually or in groups
MDSR: signal repeater. Necessary if the communication cables are more than 1000
metres long

Accessories
RNY01 or RNY11: Y-branch. The accessory is
composed of two Y-branches, one for the
liquid line and one for the discharge line.
Mandatory accessory
MDW HB: hydronic module for the production of hot water. Internal installation with
5kW or 8kW power
Mandatory accessory
HBi WT: HBI_WT: 200, 300, 350, 400 litre
DHW Storage Tank with main coil and 3kW
electric support resistance
- Magnesium sacrificial anode
- Stainless steel tank and coil
- Outdoor covering in painted sheet steel and
heat insulation material, thickness 50mm
-Indoor installation
Mandatory accessory (as an alternative to

MDW100
MDW120
MDW140
MDW160

456

MDW50HB

MDW80HB

Compatibility
HBi200WT/WTS

HBi300WT/WTS

HBi350WT/WTS

HBi400WT/WTS

Operating mode
Cooling only

Heating only

Hot domestic water

Heating + hot domestic water

Cooling + hot domestic water

Cooling only:
- outside air temp. from -5C D.B. to 48C D.B..

Heating only:
- outside air temp. from -20C D.B. to 24C D.B

Cooling + hot domestic water:


- outside air temp. from -5C D.B. to 43C D.B.
- accumulation water temp. from 35C to 58C*

Heating + hot domestic water:


- outside air temp. from -15C D.B. to 24C D.B.
- accumulation water temp. from 35C to 58C*

Hot domestic water only:


- outside air temp. from -15C D.B. to 43C D.B.
- accumulation water temp. from 35C to
58C*C a 58C*

* The maximum temperature that can be set from the wired panel (MDW HB) is 58C. It is, however, possible - via a combination of keys - to modify the upper limit,
bringing it from 58C (default) to 65C

Example of connection
Wired panel
for MDW HB

Supplementary heat sources


The supplementary coil is
only present in HBi WTS
models

MDW HB

User

R410A
R410A

The main coil is present


in all HBi WT / WTS
models

Technical water

Technical water

Aqueduct
HBi WT
HBi WTS

MDW
RNY*

RNY*
RNY* = RNY01 or RNY11

RNY*

R410A

RNY*

RNY*

RNY*

R410A

MDS WN

MDS C

MDS DH

MDS F

457

Technical data of direct expansion indoor unit


Internal units
Cooling capacity
Heating capacity
Air flow
Moisture removed
Total power input
Sound pressure (min)
Sound pressure (max)
Cooling connections

MDS
W
W
3
m /h
l/h
W
dB (A)
dB (A)
liquid
gas
Type

Internal units
Cooling capacity
Heating capacity
Air flow
Moisture removed
Total power input
Sound pressure (max)
Cooling connections

MDS
W
W
3
m /h
l/h
W
dB (A)
liquid
gas
Type

Internal unit
Cooling capacity
Heating capacity
Air flow
Moisture removed
Total power input
Sound pressure (min)
Sound pressure (max)
Cooling connections

MDS
W
W
3
m /h
l/h
W
dB (A)
dB (A)
liquid
gas
Type

Internal unit
Cooling capacity
Heating capacity
Air flow
Total power input
Sound pressure (max)
Cooling connections

MDS
W
W
m3/h
W
dB (A)
liquid
gas
Type

22WN
2200
2500
360
1
32
28
31
6.35(1/4)
9.52(3/8)
flare

28WN
2800
3200
360
1
32
28
31
6.35(1/4)
9.52(3/8)
flare

36WN
3600
4000
500
1.2
48
32
35
6.35(1/4)
12.7(1/2)
flare

45WN
4500
5000
500
1.2
48
32
35
6.35(1/4)
12.7(1/2)
flare

28CS
2800
3200
600
0.8
12
47
6.35(1/4)
9.52(3/8)
flare
28C
2800
3200
680
0.8
60
34
37
6.35(1/4)
9.52(3/8)
flare

36C
3600
4000
680
0.8
60
34
37
6.35(1/4)
12.7(1/2)
flare

50WN
5000
5800
700
2
56
38
42
6.35(1/4)
12.7(1/2)
flare

36CS
3600
4000
600
0.8
12
47
6.35(1/4)
12.7(1/2)
flare

45C
4500
5000
680
1.2
65
34
37
6.35(1/4)
12.7(1/2)
flare

50C
5000
5500
680
1.2
65
34
37
6.35(1/4)
12.7(1/2)
flare

56C
5600
6300
1180
1.9
83
35
39
9.52(3/8)
15.9(5/8)
flare

56WN
5600
6300
750
2
58
40
45
9.52(3/8)
15.9(5/8)
flare
45CS
4500
5000
600
1.2
12
47
6.35(1/4)
12.7(1/2)
flare

71C
7100
8000
1180
1.9
83
35
39
9.52(3/8)
15.9(5/8)
flare

90C
9000
10000
1860
2.7
133
36
40
9.52(3/8)
15.9(5/8)
flare

112C
11200
12500
1860
2.7
133
36
40
9.52(3/8)
15.9(5/8)
flare

28F
2800
3200
550
19
37
6.35(1/4)
9.52(3/8)
flare

36F
3600
4000
600
19
38
6.35(1/4)
12.7(1/2)
flare

50F
5000
5800
700
75
47
6.35(1/4)
12.7(1/2)
flare

71F
7100
8000
1170
185
50
9.52(3/8)
15.9(5/8)
flare

112F
11200
12500
2200
280
53
9.52(3/8)
15.9(5/8)

flare

Internal units

MDS

22DH

28DH

36DH

45DH

56DH

Cooling capacity

2200

2800

3600

4500

5600

Heating capacity

2500

3200

4000

5000

6300

m /h

450

570

570

700

1000

Moisture removed

l/h

0.7

0.9

0.9

1.3

2.1

Total power input

85

90

90

150

240

Sound pressure

dB (A)

37

39

39

40

44

Cooling connections

liquid

6.35(1/4)

6.35(1/4)

6.35(1/4)

6.35(1/4)

9.52(3/8)

gas

9.52(3/8)

9.52(3/8)

12.7(1/2)

12.7(1/2)

15.9(5/8)

Type

flare

flare

flare

flare

flare

Air flow

Indoor units

MDS

71DH

90DH

112DH

140DH

Cooling capacity

7100

9000

11200

14000

Heating capacity

8000

10000

12500

14500

1100

1700

1700

2000

Air flow

m /h

Moisture removed

l/h

2.1

Total power input

240

360

360

500

Sound pressure

dB (A)

45

48

48

50

Cooling connections

liquid

9.52(3/8)

9.52(3/8)

9.52(3/8)

9.52(3/8)

gas

15.9(5/8)

15.9(5/8)

15.9(5/8)

15.9(5/8)

Type

flare

flare

flare

flare

Indoor unit power supply: 230V~50Hz


Performance values refer to the following conditions:
Sound pressure measured at 1m in semi-anechoic chamber
Cooling:
- room air temperature
27C D.B. 19C W.B.
- outside air temperature
35C D.B.

Sound pressure measured at 1.4m in semi-anechoic chambe


Heating:
- room air temperature
20C D.B.
- outside air temperature
7C D.B. 6C W.B.

Technical data for hot domestic water accumulation tank


Hot domestic water accumulation tank

HBi

Capacity

200WT

200WTS

300WT

300WTS

350WT

350WTS

400WT

400WTS

200

200

300

300

350

350

400

Electric resistor power

400

kW

Electric resistor input current

13

13

13

13

13

13

13

13

Power supply

230V ~ 50Hz

User water connections (In / Out)

G1/2

G1/2

G1/2

G1/2

G1/2

G1/2

G1/2

G1/2

Main coil water connections (In / Out)

G3/4

G3/4

G3/4

G3/4

G3/4

G3/4

G3/4

G3/4

Supplementary coil water connections (In / Out)

G3/4

G3/4

G3/4

G3/4

Supplementary coil

10

10

10

10

xs

mm

22 x 0.8

22 x 0.8

22 x 0.8

22 x 0.8

458

Technical data of the external units and hydronic modules


Outdoor units
Cooling capacity (nominal)
Input power (nominal)
Heating capacity (nominal)
Input power (nominal)
Max input power
Total connectable power (min/max)
Connectable direct expansion indoor units (min/max)
Twin Rotary compressors
Fans
Sound pressure (max)
Refrigerant charge
Length of cooling lines (max)
Level difference of indoor unit / indoor unit (max)
Level difference of outdoor unit / indoor unit (max)
Cooling connections (towards indoor units)

Cooling connections (towards MDW_HB)

MDW
kW
kW
kW
kW
kW
kW
n
2/6
nx Type
nx Type
dB (A)
Kg
m
m
U. Outdoor unit higherm m
U. Outdoor unit lower m
liquid
gas
Type
liquid
gas
Type

Power supply

measured at 1m at the front in semi-anechoic chamber


Cooling only:
- room air temperature
27C D.B. 19C W.B.
- outside air temperature
35C D.B.

140
14
5,5
15,4
4,9
6,5
8/16
2/7
1 x DC Inverter
2 x DC Inverter
58
7
150
10
25
20
9,52 (3/8)
19,05 (3/4)
are
12,7 (1/2)
15,9 (5/8)
are

1 x DC Inverter
2 x DC Inverter
60
7
150
10
25
20
9,52 (3/8)
19,05 (3/4)
are
12,7 (1/2)
15,9 (5/8)
are

230V ~ 50Hz

230V ~ 50Hz

230V ~ 50Hz

230V ~ 50Hz

Capacity
Head (max)

Cooling connections towards outdoor unit

Water connections (In / Out)


Length of hydraulic lines Hydronic module / Tank (max)
Power supply

(*) Hot domestic water only:


outside air temperature
initial / final temperature of water in the accumulation tank

160
16
5,9
17,6
5,3
6,8
8/16

20C D.B.
7C D.B. 6C W.B.

MDW
kW
l/min
m
W
m
m
liquid
gas
Type

Total power input


Length of cooling lines (max)
Level difference of outdoor unit / hydronic module

120
12
5,0
14
4,2
6,2
8/13
2/7
1 x DC Inverter
2 x DC Inverter
56
5
150
10
25
20
9,52 (3/8)
19,05 (3/4)
are
12,7 (1/2)
15,9 (5/8)
are

Heating only:
- room air temperature
- outside air temperature

Hot domestic water hydronic module


Heating capacity (nominal)*
Technical water circulator

100
10
4,5
11
3,8
5,7
8/13
2/6
1 x DC Inverter
2 x DC Inverter
56
5
150
10
25
20
9,52 (3/8)
19,05 (3/4)
are
12,7 (1/2)
15,9 (5/8)
are

50HB
5
16,7
6
80
10
5
12,7 (1/2)
15,9 (5/8)
are
G3/4
5

80HB
8
16,7
6
80
10
5
12,7 (1/2)
15,9 (5/8)
are
G3/4
5

230V ~ 50Hz

230V ~ 50Hz

20C D.B. 15C W.B.


15C / 55C

Dimensional data (mm)

MDS22WN
MDS28WN
MDS36WN
MDS45WN
MDS50WN
MDS56WN
MDS28CS*
MDS36CS*
MDS45CS*
MDS28C**
MDS36C**
MDS45C**
MDS50C**
MDS56C**
MDS71C**
MDS90C**
MDS112C**
MDS28F
MDS36F

A
mm
770
770
830
830
1020
1020
570
570
570
840
840
840
840
840
840
840
840
695
695

B
mm
250
250
285
285
310
310
570
570
570
840
840
840
840
840
840
840
840
840
840

C
mm
190
190
189
189
228
228
230
230
230
190
190
190
190
240
240
320
320
238
238

Peso
kg
8
8
11
11
12
12
20
20
20
25
25
25
25
30
30
38
38
26
26

*: Grille dimensions MDSGL40S mm 650x650x50, Weight


= 5kg
**: Grille dimensions MDSGL40 mm 950x950x60, Weight
= 6.5kg
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

MDS50F
MDS71F
MDS112F
MDS22DH
MDS28DH
MDS36DH
MDS45DH
MDS56DH
MDS71DH
MDS90DH
MDS112DH
MDS140DH
MDW100
MDW120
MDW140
MDW160
MDW50HB
MDW80HB
HBi200WT / WTS
HBi300WT / WTS
HBi350WT / WTS
HBi400WT / WTS

MDS CS
MDS C

MDW HB

MDS WN

A
mm
695
600
695
880
880
880
980
1155
1155
1425
1425
1425
1250
1250
1250
1250
250
250
1595
1620
1895
2125

B
mm
840
1300
1590
665
665
665
721
756
756
756
756
756
950
950
950
950
650
650
540
620
620
620

C
mm
238
188
238
250
250
250
266
300
300
300
300
300
340
340
340
340
300
300
/
/
/
/

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293730
www.aermec.com

Peso
kg
26
32
42
29
31
31
36
51
51
64
64
66
105
105
115
115
25
25
68/71
82/87
96/100
106/110

MDW

HBi WT
HBi WTS

459

Code: SMDWUY.01 / 1502

MDS F

MDS DH

MVF-MDS

Multisplit heat pumps with Variable Refrigerant Flow


System (VRF) with capacities from 10 up to 60 kW

R410A

MDS WN

MDS C

MDS DH
MDS F

MVF100 - MVF120
MVF140 - MVF140T
MVF160T - MDS120

Wire control panel

MDS260T
MDS300T

MDS450T

Infrared remote
control

Silencer for MDS WN


and MDS F

MDS560T
MDS600T

Characteristics
Available in 6 versions of MDS condensing units
and 5 versions of MDS condensing units MVF.
Combination with different types of indoor
units: wall (MDS WN), cassette (MDS C / CS),
foor-ceiling (MDS F) and duct type (MDS DH)
From 2 to 32 indoor units can be connected
R410A refrigerant gas
Total power connectable to the outdoor unit
between 50% and 135% of its rated power
Wire control panel standard on all indoor units
Infrared remote control standard on all indoor units
DC Inverter (MVF) and Digital scroll compressors (MDS) have been chosen to maximise efficiency, reduce consumption, and mini-

mise peak absorption to efficiently check the


oil return to the compressor, to optimize the
ambient temperature and humidity
MVF outdoor unit is equipped by two fans
with Inverter AC motor variable speed.
Microprocessor control
In the MDS systems, the refrigerator connections are created using braze welded Y-shunts
(supplied as a mandatory accessory), ensuring
flexibility in the installation and full respect for
the safety regulations, as well as lower environmental impact due to the absence of leaks
Extremely quiet operation
Air filter easy to remove and regeneratable

Maximum length of refrigerator lines up to


150m for the MVF100, MVF120, MVF140,
MVF140T, MVF160T units
Maximum length of refrigerator lines up to
300m for the MDS120 units; up to 500m for
the MDS260T, MDS 300T, MDS450T,
MDS560T and MDS600T units
Auto-Restart enabled by default if necessary
disabled
Condensation control device as standard
supply; enables operation even with low
outdoor temperatures

Accessories
RNY11: Y-shunt for total installed power
downstream less than or equal to 20 kW; the
accessory is composed of two Y-shunts, one
for the liquid line and one for the gas line.
RNY12: Y-shunt for total installed power
downstream greater than 20 kW but less than
or equal to 30 kW; the accessory is composed
of two Y-shunts, one for the liquid line and
one for the gas line.
RNY21: Y-shunt for total installed power
downstream greater than 30 kW; the accessory is composed of two Y-shunts, one for the
liquid line and one for the gas line.

460

MDSGL40S: Air delivery/return grille. This is a MDSR: Signal repeater; necessary if the communication cables are more than 1000 metres
mandatory accessory, as the MDS CS units are
long.
delivered without them.
MDSGL40: Air delivery/return grille. This is a ECD: Kit remote contact. Allows you to manage the on / off indoor units with direct expanmandatory accessory, as the MDS C units are
sion via external contact
delivered without them.
MDSCC1: Centralised control by means of which MDSRC: Simplified control panel for centraliup to 64 communication modules (MDSCM1
zed control. Allows you to control the direct
accessory) can be handled, for a maximum of 64
expansion indoor units individually or in
outdoor units and 1024 indoor units.
groups
MDSCM1: Communication module. Up to 16
indoor units and the related outdoor unit can
be connected to each module.

Connection examples

RNY

RNY

RNY

MDS/MVF

MDS C

RNY

RNY

RNY

RNY

RNY

MDS F

MDS WN

MDS WN

MDS C
MDS WN

MDS WN

MDS DH

MDS F

Technical data
MVF
100

MVF
120

MVF
140

MVF
140T

MVF
160T

MDS
120

MDS
260T

MDS
300T

MDS
450T

MDS
560T

MDS
600T

kW

10

12

14

14

16

12

26

30

45

56

60
19,2

Outdoor units
Cooling capacity
(nominal)
Total absorbed power
(nominal)
EER
Heating capacity
(nominal)
Absorbed power
(nominal)
COP
Maximum absorbed
power (1)
Total input power
(min/max)
Max. number of units
connectable

Compressors

kW

2,86

3,50

4,36

4,50

5,10

3,9

8,5

9,0

14,5

18,5

W/W

3,50

3,43

3,21

3,11

3,14

3,33

kW

11

14

15,4

15,4

17,6

14

28,5

33,5

48

60

63
18,2

kW

2,60

3,40

4,05

4,30

4,80

3,8

8,0

8,8

13,7

18

W/W

4,23

4,12

3,80

3,58

3,67

3,8

kW

5,9

6,1

6,1

6,6

15

15

20,3

28

30

kW

5/13,5

6/16,2

7/18,9

7/18,9

8/21,6

6/16,2

13/35,1

15/40,5

22,5/60,8

28/75,6

30/81

n.

16

16

16

32

32

--

--

--

--

--

--

--

--

--

--

--

DC
Inverter
Digital
Scroll
Scroll
On/Off
m/h
m

Air ow
Lung. max. linee
Max. height difference.
m
(indoor-indoor unit)
Max. height difference
m
(outdoor-outdoor unit)*2
Max. height difference
m
(indoor-outdoor unit)**3
Fans
n.
Sound pressure
dB (A)

liquid
Refrigerator

connections
gas
Type
Feeding

--

--

--

--

--

--

6000
150

6000
150

6000
150

6000
150

6000
150

5820
300

12000
500

12000
500

12000
500

20000
500

24000
500

10

10

10

10

10

10

15

15

15

15

15

30

30

30

30

30

30

50

50

50

50

50

25

25

25

25

25

25

40

40

40

40

40

2
58
9,52
(3/8)
15,9
(5/8)
are

2
58
9,52
(3/8)
15,9
(5/8)
are

2
58
9,52
(3/8)
15,9
(5/8)
are

2
2
2
1
1
1
2
2
58
60
58
58
58
60
60
60
9,52
9,52
9,52
9,52
9,52
12,7
15,9
15,9
(3/8)
(3/8)
(3/8)
(3/8)
(3/8)
(1/2)
(5/8)
(5/8)
15,9
19
15,9
22,2
22,2
28,6
28,6
28,6
(5/8)
(3/4)
(5/8)
(7/8)
(7/8)
(1 1/8) (1 1/8) (1 1/8)
are
are
are
brazing brazing brazing brazing brazing
400V~3N 400V~3N
3N~400V 3N~400V 3N~400V 3N~400V 3N~400V
230V~50Hz 230V~50Hz 230V~50Hz
230V~50Hz
50Hz
50Hz
50Hz
50Hz
50Hz
50Hz
50Hz

(1) = according to the Standard EN-60335


(2) = outdoor unit installed in a higher position than the indoor unit
(3) = outdoor unit installed in a lower position than the indoor unit
misurata a 1 m frontale in camera semianecoica
measured at 1 m frontal in semianechoic chamber.
Cooling:
- room air temperature 27 C D.B., 19 C W.B.
- outdoor air temperature 35 C D.B.

Heating:
- room air temperature 20 C D.B.
- outdoor air temperature 7 C D.B., 6 C W.B.

461

Technical data
Indoor units
Cooling capacity
Heating capacity
Air ow
Moisture removed
Total absorbed power
* Sound pressure (min.)
* Sound pressure (max.)
Refrigerator connections

MDS
W
W
m3/h
l/h
W
dB (A)
dB (A)
liquid
gas
Tipy

Feeding
Indoor units
Cooling capacity
Heating capacity
Air ow
Moisture removed
Total absorbed power
** Sound pressure (min.)
** Sound pressure (max.)
Refrigerator connections

MDS
W
W
m3/h
l/h
W
dB (A)
dB (A)
liquid
gas
Type

Feeding
Indoor units
Cooling capacity
Heating capacity
Air ow
Moisture removed
Total absorbed power
ee Sound pressure (max.)
Refrigerator connections

22WN
2200
2500
360
1
32
28
31
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

Refrigerator connections

MDS
W
W
m3/h
l/h
W
dB (A)
liquid
gas
Type

Refrigerator connections

Refrigerator connections
Feeding

28CS
2800
3200
600
0,8
12
47
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

36CS
3600
4000
600
0,8
12
47
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

45CS
4500
5000
600
1,2
12
47
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

36F
3600
4000
600
19
38
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

50F
5000
5800
700
75
47
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

71F
7100
8000
1170
185
50
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

112F
11200
12500
2200
280
53
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

MDS
W
W
m3/h
l/h
W
dB (A)
liquid
gas
Type

22DH
2200
2500
450
0,7
85
37
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

28DH
2800
3200
570
0,9
90
39
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

36DH
3600
4000
570
0,9
90
39
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

45DH
4500
5000
700
1,3
150
40
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

56DH
5600
6300
1000
2,1
240
44
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

MDS
W
W
m3/h
l/h
W
dB (A)
liquid
gas
Type

71DH
7100
8000
1100
2,1
240
45
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

The performance data refer to the following conditions:


* measured at 1 m in semianechoic chamber
** measured at 1.4 m in semianechoic chamber
Cooling:
- room air temperature 27 C D.B., 19 C W.B.
- outdoor air temperature 35 C D.B.

462

50WN
56WN
5000
5600
5800
6300
700
750
2
2
56
58
38
40
42
45
6,35(1/4)
9,52(3/8)
12,7(1/2)
15,9(5/8)
are
are
230V ~ 50Hz 230V ~ 50Hz

28F
2800
3200
550
19
37
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

Feeding
Indoor units
Cooling capacity
Heating capacity
Air ow
Moisture removed
Total absorbed power
** Sound pressure

45WN
4500
5000
500
1,2
48
32
35
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

MDS
W
W
m3/h
W
dB (A)
liquid
gas
Type

Feeding
Indoor units
Cooling capacity
Heating capacity
Air ow
Moisture removed
Total absorbed power
** Sound pressure

36WN
3600
4000
500
1,2
48
32
35
6,35(1/4)
12,7(1/2)
are
230V ~ 50Hz

28C
36C
45C
50C
56C
71C
90C
112C
2800
3600
4500
5000
5600
7100
9000
11200
3200
4000
5000
5500
6300
8000
10000
12500
680
680
680
680
1180
1180
1860
1860
0,8
0,8
1,2
1,2
1,9
1,9
2,7
2,7
60
60
65
65
83
83
133
133
34
34
34
34
35
35
36
36
37
37
37
37
39
39
40
40
6,35(1/4)
6,35(1/4)
6,35(1/4)
6,35(1/4)
9,52(3/8)
9,52(3/8)
9,52(3/8)
9,52(3/8)
9,52(3/8)
12,7(1/2)
12,7(1/2)
12,7(1/2)
15,9(5/8)
15,9(5/8)
15,9(5/8) 15,9(5/8)
are
are
are
are
are
are
are
are
230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz

Feeding
Indoor units
Cooling capacity
Heating capacity
Air ow
Total absorbed power
** Sound pressure (max.)

28WN
2800
3200
360
1
32
28
31
6,35(1/4)
9,52(3/8)
are
230V ~ 50Hz

90DH
9000
10000
1700
3
360
48
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

112DH
11200
12500
1700
3
360
48
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

Heating:
- room air temperature 20 C D.B.
- outdoor air temperature 7 C D.B., 6 C W.B

140DH
14000
14500
2000
3
500
50
9,52(3/8)
15,9(5/8)
are
230V ~ 50Hz

Dimensional data (mm)

MDS WN

MDS F

MDS CS / C

MDS DH

MDS450T
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

B
(mm)
770
770
830
830
1020
1020
840
840
840
840
840
840
840
840
570
570
570
840
840
840
1300
1590
665
665
665
721
756
756
756
756
756
950
950
950
950
950
1100
990
990
1290
1980
1980

C
(mm)
190
190
189
189
228
228
190
190
190
190
240
240
320
320
230
230
230
238
238
238
188
238
250
250
250
266
300
300
300
300
300
340
340
340
340
340
340
880
880
880
920
920

weight
(kg)
8
8
11
11
12
12
25
25
25
25
30
30
38
38
20
20
20
26
26
26
32
42
29
31
31
36
51
51
64
64
66
111
111
111
115
115
140
280
300
450
600
600

*: MDSGL40 grille 950x950x60 mm;


Weight = 6,5 kg;
**: MDSGL40S grille650x650x50 mm;
Weight = 5 kg;
MDS260T - MDS300T

Cod.: SMDSUY.05 / 1302

MVF100 - MVF120
MVF140 - MVF140T
MVF160T
MDS120

MDS22WN
MDS28WN
MDS36WN
MDS45WN
MDS50WN
MDS56WN
MDS28C*
MDS36C*
MDS45C*
MDS50C*
MDS56C*
MDS71C*
MDS90C*
MDS112C*
MDS28CS**
MDS36CS**
MDS45CS**
MDS28F
MDS36F
MDS50F
MDS71F
MDS112F
MDS22DH
MDS28DH
MDS36DH
MDS45DH
MDS56DH
MDS71DH
MDS90DH
MDS112DH
MDS140DH
MVF100
MVF120
MVF140
MVF140T
MVF160T
MDS120
MDS260T
MDS300T
MDS450T
MDS560T
MDS600T

A
(mm)
250
250
285
285
310
310
840
840
840
840
840
840
840
840
570
570
570
695
695
695
600
695
880
880
880
980
1155
1155
1425
1425
1425
1250
1250
1250
1250
1250
1250
1772
1772
1772
1760
1760

MDS560T - MDS600T
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577
www.aermec.com

463

NEW

MVA
Version S

Multi-split reversible heat pumps


Variable Refrigerant Flow System (VRF)
Cooling capacity from 12.1kW to 28.0kW
Heating capacity from 14.0kW to 30.0kW

R410A
MVA_W

MVA_F

WRC

WLRC

MVA_FS

MVA_C
MVAS

MVA_D

Features

Outdoor units available in 9 outdoor unit sizes


Indoor Units:
Wall (MVA_W) for wall installation
600x600 boxes (MVA_CS) for suspended ceiling
installation (Mandatory accessory GL40S)
840x840 boxes (MVA_C) for suspended ceiling
installation (Mandatory accessory GL40)
910x910 boxes (MVA_CB) for suspended ceiling
installation (Mandatory accessory GL40B)
Floor Ceiling (MVA_F) for floor or ceiling installation
Console (MVA_FS) for floor installation
Low Static Pressure Duct (MVA_D) for horizontal ceiling installation
High Static Pressure Duct (MVA_DH) for horizontal ceiling installation
From 2 to 17 connectable indoor units
R410A refrigerant gas
Total power that can be connected to the out-

door units ranging between 50% and 135%


of the rated power of the chosen configuration
WRC wired control panel, for wall installation, as standard on all the indoor units
WLRC infrared remote control, as standard
on all the indoor units
The DC Inverter compressors have been
selected to maximise efficiency, reduce consumption, minimise peak current absorption,
to have an efficient control of the oil return
and precise control of room temperature and
humidity
Outdoor units equipped with two fans with
variable-speed Inverter motors
Microprocessor control
In the MVA systems, the refrigerant connections are created using the braze-welded

Y-joints (available as mandatory accessories),


ensuring installation flexibility and full compliance with the safety standards, in addition
to lower environmental impact due to the
absence of leaks
Extremely silent functioning
Total maximum length of the refrigerant lines
up to 250m
Auto-Restart function active by default with
possibility to disable
Condensation control device as standard;
ensures functioning in cooling mode even
with low external temperatures
Serial communication in CAN Bus protocol
Easy installation thanks to the non-polarised
serial connections and the self-addressing
functions

Accessories
RNY11: Y-joint for total power installed
downstream less than or equal to 20 kW; the
accessory consists of two Y-joints, one for the
liquid line and one for the gas line
RNY12: Y-joint for total power installed
downstream above 20 kW but less than or
equal to 30 kW; the accessory consists of two
Y-joints, one for the liquid line and one for
the gas line
RNY21: Y-joint for total power installed
downstream above 30 kW but less than or
equal to 70 kW; the accessory consists of two
Y-joints, one for the liquid line and one for
the gas line

464

GL40: Air flow and return grid for box type WRC: wired control panel; it can be purindoor units
chased separately to control several indoor
Mandatory accessory for MVA_C
units from two wired control panels
GL40S: Air flow and return grid for box type WRCS: simplified wired control panel with
indoor units
integrated external contact. This panel is parMandatory accessory for MVA_CS
ticularly suitable for hotel applications
GL40B: Air flow and return grid for box type WLRCE: evolved infrared remote control
indoor units
Mandatory accessory for MVA_CB
MODBUSGW: this accessory is used to manage up to 16 MVA systems (up to a maximum
of 256 total indoor units), making a Modbus
serial available for supervision with an external BMS

Example of connection

RNY

RNY

RNY

MVAS
MVA_C

RNY

MVA_W

MVA_W

MVA_F
RNY

RNY

RNY

RNY

MVA_C
MVA_W

MVA_W

MVA_DH

MVA_F

Technical data
Outdoor units
Cooling capacity (nominal)
Total input power (nominal)
Input current (nominal)
EER
Heating capacity (nominal)
Input power (nominal)
Input current (nominal)
COP
Compressors
Gas load
Air ow rate
Max. line length (equivalent)
Centrifugal
Sound pressure
liquid
Refrigerant
gas
connections
Type
Electric power supply

MVAS
kW
kW
A
W/W
kW
kW
A
W/W
DC Inverter
kg
m/h
m
no.
dB (A)
mm (inch)
mm (inch)

1200S
12.1
3.05
15
3.97
14
3.27
15.8
4.28
1
5
6000
150
2
55

1400S
14
3.98
19.2
3.52
16.5
3.99
19.3
4.14
1
5
6300
150
2
56

1600S
16
4.85
23.4
3.30
18.5
4.67
23
3.96
1
5
6600
150
2

1600T
16
4.85
7.6
3.30
18.5
4.67
7.8
3.96
1
5
6600
120
2
58

2240T
22.4
6.7
13
3.34
25
6.54
12.7
3.82
2
7.2
9000
120
2
60

2500T
25
7.4
13.5
3.38
28
7.35
12.9
3.81
2
7.6
9000
120
2
61

2800T
28
8.3
14.6
3.37
30
8.15
14.1
3.68
2
7.6
9000
120
2
61

9.52(3/8")
15.9(5/8")

9.52(3/8")
15.9(5/8")

9.52(3/8")

9.52(3/8")

19.05(3/4")

19.05(3/4")

9.52(3/8")
22.2(7/8")

9.52(3/8")
22.2(7/8")

9.52(3/8")
22.2(7/8")

Flared
(1)

Flared
(1)

Flared
(1)

Flared
(2)

Welded
(2)

Welded
(2)

Welded
(2)

(1) Electric power supply 220-240V~50Hz


(2) Electric power supply 380-415V 3N~50Hz
measured at 1 frontal m in semianechoic chamber
The efficiencies are in accordance with standard EN-14511
Cooling:
- Room air temperature 27 C D.B. ; 19 C W.B.
- External air temperature 35 C D.B.

Heating:
- Room air temperature 20 C D.B.
- External air temperature 7 C D.B. ; 6 C W.B.

465

Wall

Technical data
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220D
2200
2500
450
25
31
6.35 (1/4")
9.52 (3/8")

250D
2500
2800
450
25
31
6.35 (1/4")
9.52 (3/8")

280D
2800
3200
450
25
31
6.35 (1/4")
9.52 (3/8")

320D
3200
3600
550
27
32
6.35 (1/4")
12.7 (1/2")

360D
3600
4000
550
27
32
6.35 (1/4")
12.7 (1/2")

400D
4000
4500
700
28
33
6.35 (1/4")
12.7 (1/2")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

450D
4500
5000
700
28
33
6.35 (1/4")
12.7 (1/2")

500D
5000
5600
700
28
33
6.35 (1/4")
12.7 (1/2")

560D
5600
6300
1000
30
35
9.52 (3/8")
15.9 (5/8")

630D
6300
71000
1000
30
35
9.52 (3/8")
15.9 (5/8")

710D
7100
8000
1000
30
35
9.52 (3/8")
15.9 (5/8")

800D
8000
9000
1100
31
36
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

560DH
5600
6300
1000
36
44
9.52 (3/8")
15.9 (5/8")

630DH
6300
7100
1000
36
44
9.52 (3/8")
15.9 (5/8")

710DH
7100
8000
1100
37
45
9.52 (3/8")
15.9 (5/8")

800DH
8000
9000
1100
37
45
9.52 (3/8")
15.9 (5/8")

900DH
9000
10000
1700
42
46
9.52 (3/8")
15.9 (5/8")

1000DH
10000
11200
1700
42
46
9.52 (3/8")
15.9 (5/8")

1120DH
11200
12500
1700
42
46
9.52 (3/8")
15.9 (5/8")

1250DH
12500
14000
2000
42
48
9.52 (3/8")
15.9 (5/8")

1400DH
14000
16000
2000
44
48
9.52 (3/8")
15.9 (5/8")

1600DH
16000
17000
2650
46
48
9.52 (3/8")
19.05(3/4")

2240DH
22400
25000
4000

2800DH
28000
31000
4400

liquid
Refrigerant connections
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

54
9.52 (3/8")
22.2 (7/8")

55
9.52 (3/8")
22.2 (7/8")

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220CS
2200
2500
600
41
51
6.35 (1/4")
9.52 (3/8")

280CS
2800
3200
600
41
51
6.35 (1/4")
9.52 (3/8")

360CS
3600
4000
600
41
51
6.35 (1/4")
12.7 (1/2")

450CS
4500
5000
700
45
55
6.35 (1/4")
12.7 (1/2")

500CS
5000
5600
700
45
55
6.35 (1/4")
12.7 (1/2")

560CS
5600
6300
700
45
55
9.52 (3/8")
15.9 (5/8")

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Low static pressure duct

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

Small boxes

High static pressure duct

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

liquid
gas

Boxes

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

466

900D
9000
10000
1500
32
40
9.52 (3/8")
15.9 (5/8")

1000D
10000
11200
1500
32
40
9.52 (3/8")
15.9 (5/8")

1120D
11200
12500
1700
32
40
9.52 (3/8")
15.9 (5/8")

1250D
12500
14000
2000
37
42
9.52 (3/8")
15.9 (5/8")

1400D
14000
16000
2000
37
42
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

280C
2800
3200
750
36
6.35 (1/4")
9.52 (3/8")

360C
3600
4000
750
36
6.35 (1/4")
12.7 (1/2")

450C
4500
5000
750
36
6.35 (1/4")
12.7 (1/2")

500C
5000
5600
830
36
6.35 (1/4")
12.7 (1/2")

560C
5600
6300
1000
37
9.52 (3/8")
15.9 (5/8")

630C
6300
7100
1000
37
9.52 (3/8")
15.9 (5/8")

710C
7100
8000
1180
38
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

800C
8000
9000
1180
38
9.52 (3/8")
15.9 (5/8")

900C
9000
10000
1500
40
9.52 (3/8")
15.9 (5/8")

1000C
10000
11200
1500
40
9.52 (3/8")
15.9 (5/8")

1120C
11200
12500
1700
41
9.52 (3/8")
15.9 (5/8")

1250C
12500
14000
1860
43
9.52 (3/8")
15.9 (5/8")

1400C
14000
16000
1860
43
9.52 (3/8")
15.9 (5/8")

1600CB
16000
17500
2100
47
9.52 (3/8")
15.9 (5/8")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

220W
280W
360W
450W
500W
560W
630W
710W
2200
2800
3600
4500
5000
5600
6300
7100
2500
3200
4000
5000
5800
6300
7000
7500
500
500
630
630
630
750
750
750
34
34
38
38
38
38
38
38
38
38
44
44
44
44
44
44
6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 9.52 (3/8") 9.52 (3/8") 9.52 (3/8")
9.52 (3/8") 9.52 (3/8") 12.7 (1/2") 12.7 (1/2") 12.7 (1/2") 15.9 (5/8") 15.9 (5/8") 15.9 (5/8")

Technical data

Console

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220FS
2200
2500
400
38
6.35 (1/4")
9.52 (3/8")

280FS
2800
3200
400
38
6.35 (1/4")
9.52 (3/8")

360FS
3600
4000
480
40
6.35 (1/4")
9.52 (3/8")

450FS
4500
5000
680
46
6.35 (1/4")
12.7 (1/2")

500FS
5000
5500
680
46
6.35 (1/4")
12.7 (1/2")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
e Sound pressure (min.)
e Sound pressure (max.)
liquid
Refrigerant connections
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

280F
2800
3600
650
32
36
6.35 (1/4")
9.52 (3/8")

360F
3600
4000
650
32
36
6.35 (1/4")
12.7 (1/2")

500F
5000
5600
950
33
42
6.35 (1/4")
12.7 (1/2")

630F
6300
7100
1400
39
44
9.52 (3/8")
15.9 (5/8")

710F
7100
8000
1400
39
44
9.52 (3/8")
15.9 (5/8")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

Floor ceiling

Refrigerant connections

Refrigerant connections

liquid
gas

900F
9000
11200
1600
43
50
9.52 (3/8")
15.9 (5/8")

1120F
11200
12500
2000
42
51
9.52 (3/8")
15.9 (5/8")

1250F
12500
14000
2000
45
52
9.52 (3/8")
15.9 (5/8")

1400F
14000
16000
2000
45
52
9.52 (3/8")
15.9 (5/8")

Electric power supply: 220-240V~50Hz; All the refrigerant connections of the indoors units are flared
The performance refers to the following conditions:
measured at 1 m in semianechoic chamber
Cooling:
- Room air temperature 27 C D.B. ; 19 C W.B.
- External air temperature 35 C D.B.

Heating:
- Room air temperature 20 C D.B.
- External air temperature 7 C D.B. ; 6 C W.B.

MVA_W

MVA_F

MVA_C / CS / CB
MVA_D / DH

MVA_FS

MVAS

MVA220W
MVA280W
MVA360W
MVA450W
MVA500W
MVA560W
MVA630W
MVA710W
MVA220D
MVA250D
MVA280D
MVA320D
MVA360D
MVA400D
MVA450D
MVA500D
MVA560D
MVA630D
MVA710D
MVA800D
MVA900D
MVA1000D
MVA1120D
MVA1250D
MVA1400D
MVA560DH
MVA630DH
MVA710DH
MVA800DH
MVA900DH
MVA1000DH
MVA1120DH
MVA1250DH
MVA1400DH
MVA1600DH
MVA2240DH
MVA2800DH

A
(mm)
275
275
298
298
298
319
319
319
700
700
700
700
700
900
900
900
1100
1100
1100
1200
1340
1340
1340
1340
1340
1271
1271
1271
1271
1229
1229
1229
1229
1229
1340
1628
1628

B
C
Weight
(mm) (mm) (kg)
843
180
9.5
843
180
9.5
940
200
11
940
200
11
940
200
11
1008 221
13
1008 221
13
1008 221
13
615
200
22
615
200
22
615
200
22
615
200
22
615
200
22
615
200
27
615
200
27
615
200
27
615
200
31
615
200
31
615
200
31
655
260
40
655
260
46
655
260
46
655
260
46
655
260
47
655
260
47
558
268
35
558
268
35
558
268
35
558
268
35
775
290
47
775
290
47
775
290
47
775
290
47
775
290
47
750
350
60
869
454
115
869
454
115

*: Grid GL40S dimensions 670x670x50 mm - 3.5 kg;


**: Grid GL40 dimensions 950x950x65 mm - 7 kg;
***: Grid GL40B dimensions 1040x1040x65 mm - 7.5 kg;

Aermec reserves the right to make all the modifications deemed


necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

A
(mm)
MVA220CS *
596
MVA280CS *
596
MVA360CS *
596
MVA450CS *
596
MVA500CS *
596
MVA560CS *
596
MVA280C **
840
MVA360C **
840
MVA450C **
840
MVA500C **
840
MVA560C **
840
MVA630C **
840
MVA710C **
840
MVA800C **
840
MVA900C **
840
MVA1000C **
840
MVA1120C **
840
MVA1250C **
840
MVA1400C **
840
MVA1600CB *** 910
MVA220FS
600
MVA280FS
600
MVA360FS
600
MVA450FS
600
MVA500FS
600
MVA280F
700
MVA360F
700
MVA500F
700
MVA630F
700
MVA710F
700
MVA900F
700
MVA1120F
700
MVA1250F
700
MVA1400F
700
Outdoor units:
MVAS1200S
1345
MVAS1400S
1345
MVAS1600S
1345
MVAS1600T
1345
MVAS2240T
1584
MVAS2500T
1584
MVAS2800T
1584

B
C
Weight
(mm) (mm) (kg)
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
840
190
25
840
190
25
840
190
25
840
190
25
840
240
30
840
240
30
840
240
30
840
240
30
840
320
35
840
320
35
840
320
35
840
320
35
840
320
35
910
293
45
700
215
16
700
215
16
700
215
16
700
215
16
700
215
16
1220 225
40
1220 225
40
1220 225
40
1420 245
50
1420 245
50
1700 245
50
1700 245
60
1700 245
60
1700 245
60
900
900
900
900
1098
1098
1098

340
340
340
340
399
399
399

110
110
110
120
175
185
185

467

Code: SMVASUY.00 / 1503

Dimensional data (mm)

NEW

MVA
Version M

Modular multi-split reversible heat pumps


Variable Refrigerant Flow System (VRF)
Cooling capacity from 22.4kW to 180.0kW
Heating capacity from 25.0kW to 200.0kW

R410A
MVA_W

MVA_F
MVA_FS

MVA_D
MVA_C
MVAM3350T - 4500T
MVAM2240T - 2800T
WLRC
WRC

Features
Outdoor Units: 5 Base Modules with
Nominal Cooling Capacity from 22.4kW to
45.0kW
Modular System: Base Modules that can be
combined, up to a maximum of 4 for a total
of 24 combinations, with Cooling Capacity
from 50.4kW to 180.0kW. The refrigerant
connection between the Base Modules must
be carried out upon installation by using specific Y-joints (Mandatory accessories
RNYM01). A Modular System consisting of n
Base Modules requires n-1 Y-joints (RNYM01)
Indoor Units:
- Wall (MVA_W) for wall installation
- 600x600 boxes (MVA_CS) for suspended ceiling
installation (Mandatory accessory GL40S)
- 840x840 boxes (MVA_C) for suspended ceiling
installation (Mandatory accessory GL40)
- 910x910 boxes (MVA_CB) for suspended ceiling
installation (Mandatory accessory GL40B)
- Floor Ceiling (MVA_F) for floor or ceiling installation
- Console (MVA_FS) for floor installation
- Low Static Pressure Duct (MVA_D) for horizontal ceiling installation
- High Static Pressure Duct (MVA_DH) for hori-

zontal ceiling installation


From 2 to 80 connectable indoor units
R410A refrigerant gas
Total power that can be connected to the outdoor units ranging between 50% and 135%
of the rated power of the chosen configuration
WRC wired control panel, for wall installation, as standard on all the indoor units
WLRC infrared remote control, as standard
on all the indoor units
The DC Inverter compressors have been
selected to maximise efficiency, reduce consumption, minimise peak current absorption,
to have an efficient control of the oil return
and precise control of room temperature and
humidity
Outdoor units equipped with fans with variable-speed Inverter motors
Microprocessor control
In the MVA systems, the refrigerant connections are created using the braze-welded
Y-joints (available as mandatory accessories),
ensuring installation flexibility and full compliance with the safety standards, in addition

to lower environmental impact due to the


absence of leaks
Extremely silent functioning
Total maximum length of the refrigerant lines
up to 1000m
Auto-Restart function active by default with
possibility to disable
Condensation control device as standard;
ensures functioning in cooling mode even
with low external temperatures
Serial communication in CAN Bus protocol
Easy installation thanks to the non-polarised
serial connections and the self-addressing
functions
Outdoor ducted units (maximum static pressure available 80Pa)
Optimised management of compressor operating time at partial loads
Indoor units with electronic expansion valve
on board
Emergency operation, in the event of problems with the compressors or fans, it ensures
system operation with less compressors and/
or compressors for a limited time

RNY21: Y-joint for total power installed


downstream above 30 kW but less than or
equal to 70 kW; the accessory consists of two
Y-joints, one for the liquid line and one for
the gas line
RNY31: Y-joint for total power installed downstream above 70 kW but less than or equal to
135 kW; the accessory consists of two Y-joints,
one for the liquid line and one for the gas line
RNY41: Y-joint for total power installed
downstream above 135 kW; the accessory
consists of two Y-joints, one for the liquid line
and one for the gas line
GL40: Air flow and return grid for box type
indoor units
Mandatory accessory for MVA_C
GL40S: Air flow and return grid for box type

indoor units
Mandatory accessory for MVA_CS
GL40B: Air flow and return grid for box type
indoor units
Mandatory accessory for MVA_CB
MODBUSGW: this accessory is used to manage up to 16 MVA systems (up to a maximum
of 256 total indoor units), making a Modbus
serial available for supervision with an external BMS
WRC: wired control panel; it can be purchased separately to control several indoor
units from two wired control panels
WRCS: simplified wired control panel with
integrated external contact. This panel is particularly suitable for hotel applications
WLRCE: evolved infrared remote control

Accessories
RNYM01: Y-joint for the refrigerant connection between 2 outdoor units in the Modular
System; the accessory consists of two Y-joints,
one for the liquid line and one for the gas
line. Mandatory accessory in the event of
Modular Systems.
A Modular System consisting of n Base
Modules requires n-1 Y-joints
RNY11: Y-joint for total power installed
downstream less than or equal to 20 kW; the
accessory consists of two Y-joints, one for the
liquid line and one for the gas line
RNY12: Y-joint for total power installed
downstream above 20 kW but less than or
equal to 30 kW; the accessory consists of two
Y-joints, one for the liquid line and one for
the gas line

468

Example of connection
MVAM

MVAM

MVAM

RNY

RNY

RNY

MVAM
MVA_F
MVA_W
RNY

MVA_C
RNY

MVA_DH
RNY

RNY
MVA_C

RNY
RNYM

RNYM

MVA_W

RNYM
RNY

RNY

MVA_W

MVA_W

RNY

MVA_F

MVA_W

RNY

MVA_C
MVA_F

MVA_DH

Available combinations
MVAM
2240T (1)
2800T (1)
3350T (1)
4000T (1)
4500T (1)
5040T (2)
5600T (2)
6150T (2)
6800T (2)
7300T (2)
7850T (2)
8500T (2)
9000T (2)
9600T (2)
(1)
(2)

Outdoor unit combinations


2240T
------2800T
------3350T
------4000T
------4500T
------2240T 2800T
----2800T 2800T
----2800T 3350T
----2800T 4000T
----2800T 4500T
----3350T 4500T
----4000T 4500T
----4500T 4500T
----2800T 2800T 4000T
---

Rated power (kW)


22.4
28
33.5
40
45
50.4
56
61.5
68
73
78.5
85
90
96

MVAM
10100T (2)
10650T (2)
11300T (2)
11800T (2)
12350T (2)
13000T (2)
13500T (2)
14100T (2)
14600T (2)
15150T (2)
15800T (2)
16300T (2)
16850T (2)
17500T (2)
18000T (2)

Outdoor unit combinations


2800T 2800T 4500T
--2800T 3350T 4500T
--2800T 4000T 4500T
--2800T 4500T 4500T
--3350T 4500T 4500T
--4000T 4500T 4500T
--4500T 4500T 4500T
--2800T 2800T 4000T 4500T
2800T 2800T 4500T 4500T
2800T 3350T 4500T 4500T
2800T 4000T 4500T 4500T
2800T 4500T 4500T 4500T
3350T 4500T 4500T 4500T
4000T 4500T 4500T 4500T
4500T 4500T 4500T 4500T

Rated power (kW)


101
106.5
113
118
123.5
130
135
141
146
151.5
158
163
168.5
175
180

Base Module
Modular system achieved by combining 2 to 4 Base Modules.
The connection between Base Modules must be carried out upon installation.

Technical data
Outdoor units
Cooling capacity (nominal)
Total input power (nominal)
Input current (nominal)
EER
Heating capacity (nominal)
Input power (nominal)
Input current (nominal)
COP
Compressors
Gas load
Air ow rate
Max. line length (equivalent)
Centrifugal
Sound Pressure
liquid
gas
Refrigerant
oil balancing
connections
Type
Electric power supply

MVAM
kW
kW
A
W/W
kW
kW
A
W/W
DC Inverter
kg
m/h
m
no.
dB (A)
mm (inch)
mm (inch)
mm (inch)

2240T
22.4
5.45
9.7
4.11
25
5.8
10.4
4.31
1
5.9
11400
165
1
60
9.52 (3/8")
19.05 (3/4")
9.52 (3/8")
welded
380-415V 3N~50Hz

2800T
28
7.3
13
3.84
31.5
7.85
14
4.01
1
6.7
11400
165
1
61
9.52 (3/8")
22.2 (7/8")
9.52 (3/8")
welded
380-415V 3N~50Hz

3350T
33.5
8.73
15.6
3.84
37.5
9.68
17.3
3.87
1
8.2
14000
165
1
63
12.7 (1/2")
25.4 (1")
9.52 (3/8")
welded
380-415V 3N~50Hz

4000T
40
11.1
19.8
3.6
45
11.5
20.6
3.91
2
9.8
14000
165
2
63
12.7 (1/2")
25.4 (1")
9.52 (3/8")
welded
380-415V 3N~50Hz

4500T
45
13.15
23.5
3.42
50
13.6
24.3
3.68
2
10.3
14000
165
2
63
12.7 (1/2")
28.6 (1" 1/8)
9.52 (3/8")
welded
380-415V 3N~50Hz

measured at 1 frontal m in semianechoic chamber


The efficiencies are in accordance with standard EN-14511
Cooling:
- Room air temperature
27 C D.B. ; 19 C W.B.
- External air temperature 35 C D.B.

Heating:
- Room air temperature
20 C D.B.
- External air temperature 7 C D.B. ; 6 C W.B.

469

Wall

Technical data
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220D
2200
2500
450
25
31
6.35 (1/4")
9.52 (3/8")

250D
2500
2800
450
25
31
6.35 (1/4")
9.52 (3/8")

280D
2800
3200
450
25
31
6.35 (1/4")
9.52 (3/8")

320D
3200
3600
550
27
32
6.35 (1/4")
12.7 (1/2")

360D
3600
4000
550
27
32
6.35 (1/4")
12.7 (1/2")

400D
4000
4500
700
28
33
6.35 (1/4")
12.7 (1/2")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

450D
4500
5000
700
28
33
6.35 (1/4")
12.7 (1/2")

500D
5000
5600
700
28
33
6.35 (1/4")
12.7 (1/2")

560D
5600
6300
1000
30
35
9.52 (3/8")
15.9 (5/8")

630D
6300
71000
1000
30
35
9.52 (3/8")
15.9 (5/8")

710D
7100
8000
1000
30
35
9.52 (3/8")
15.9 (5/8")

800D
8000
9000
1100
31
36
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

560DH
5600
6300
1000
36
44
9.52 (3/8")
15.9 (5/8")

630DH
6300
7100
1000
36
44
9.52 (3/8")
15.9 (5/8")

710DH
7100
8000
1100
37
45
9.52 (3/8")
15.9 (5/8")

800DH
8000
9000
1100
37
45
9.52 (3/8")
15.9 (5/8")

900DH
9000
10000
1700
42
46
9.52 (3/8")
15.9 (5/8")

1000DH
10000
11200
1700
42
46
9.52 (3/8")
15.9 (5/8")

1120DH
11200
12500
1700
42
46
9.52 (3/8")
15.9 (5/8")

1250DH
12500
14000
2000
42
48
9.52 (3/8")
15.9 (5/8")

1400DH
14000
16000
2000
44
48
9.52 (3/8")
15.9 (5/8")

1600DH
16000
17000
2650
46
48
9.52 (3/8")
19.05(3/4")

2240DH
22400
25000
4000

2800DH
28000
31000
4400

liquid
Refrigerant connections
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

54
9.52 (3/8")
22.2 (7/8")

55
9.52 (3/8")
22.2 (7/8")

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220CS
2200
2500
600
41
51
6.35 (1/4")
9.52 (3/8")

280CS
2800
3200
600
41
51
6.35 (1/4")
9.52 (3/8")

360CS
3600
4000
600
41
51
6.35 (1/4")
12.7 (1/2")

450CS
4500
5000
700
45
55
6.35 (1/4")
12.7 (1/2")

500CS
5000
5600
700
45
55
6.35 (1/4")
12.7 (1/2")

560CS
5600
6300
700
45
55
9.52 (3/8")
15.9 (5/8")

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Low static pressure duct

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

Small boxes

High static pressure duct

Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections
Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

liquid
gas

Boxes

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

470

900D
9000
10000
1500
32
40
9.52 (3/8")
15.9 (5/8")

1000D
10000
11200
1500
32
40
9.52 (3/8")
15.9 (5/8")

1120D
11200
12500
1700
32
40
9.52 (3/8")
15.9 (5/8")

1250D
12500
14000
2000
37
42
9.52 (3/8")
15.9 (5/8")

1400D
14000
16000
2000
37
42
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

280C
2800
3200
750
36
6.35 (1/4")
9.52 (3/8")

360C
3600
4000
750
36
6.35 (1/4")
12.7 (1/2")

450C
4500
5000
750
36
6.35 (1/4")
12.7 (1/2")

500C
5000
5600
830
36
6.35 (1/4")
12.7 (1/2")

560C
5600
6300
1000
37
9.52 (3/8")
15.9 (5/8")

630C
6300
7100
1000
37
9.52 (3/8")
15.9 (5/8")

710C
7100
8000
1180
38
9.52 (3/8")
15.9 (5/8")

liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

800C
8000
9000
1180
38
9.52 (3/8")
15.9 (5/8")

900C
9000
10000
1500
40
9.52 (3/8")
15.9 (5/8")

1000C
10000
11200
1500
40
9.52 (3/8")
15.9 (5/8")

1120C
11200
12500
1700
41
9.52 (3/8")
15.9 (5/8")

1250C
12500
14000
1860
43
9.52 (3/8")
15.9 (5/8")

1400C
14000
16000
1860
43
9.52 (3/8")
15.9 (5/8")

1600CB
16000
17500
2100
47
9.52 (3/8")
15.9 (5/8")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
Refrigerant connections

220W
280W
360W
450W
500W
560W
630W
710W
2200
2800
3600
4500
5000
5600
6300
7100
2500
3200
4000
5000
5800
6300
7000
7500
500
500
630
630
630
750
750
750
34
34
38
38
38
38
38
38
38
38
44
44
44
44
44
44
6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 9.52 (3/8") 9.52 (3/8") 9.52 (3/8")
9.52 (3/8") 9.52 (3/8") 12.7 (1/2") 12.7 (1/2") 12.7 (1/2") 15.9 (5/8") 15.9 (5/8") 15.9 (5/8")

Technical data

Console

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)
liquid
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

220FS
2200
2500
400
38
6.35 (1/4")
9.52 (3/8")

280FS
2800
3200
400
38
6.35 (1/4")
9.52 (3/8")

360FS
3600
4000
480
40
6.35 (1/4")
9.52 (3/8")

450FS
4500
5000
680
46
6.35 (1/4")
12.7 (1/2")

500FS
5000
5500
680
46
6.35 (1/4")
12.7 (1/2")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
e Sound pressure (min.)
e Sound pressure (max.)
liquid
Refrigerant connections
gas

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

280F
2800
3600
650
32
36
6.35 (1/4")
9.52 (3/8")

360F
3600
4000
650
32
36
6.35 (1/4")
12.7 (1/2")

500F
5000
5600
950
33
42
6.35 (1/4")
12.7 (1/2")

630F
6300
7100
1400
39
44
9.52 (3/8")
15.9 (5/8")

710F
7100
8000
1400
39
44
9.52 (3/8")
15.9 (5/8")

Indoor units
Cooling capacity
Heating capacity
Air ow rate
Sound pressure (min.)
Sound pressure (max.)

MVA
W
W
m3/h
dB (A)
dB (A)
mm (inch)
mm (inch)

Floor Ceiling

Refrigerant connections

Refrigerant connections

liquid
gas

900F
9000
11200
1600
43
50
9.52 (3/8")
15.9 (5/8")

1120F
11200
12500
2000
42
51
9.52 (3/8")
15.9 (5/8")

1250F
12500
14000
2000
45
52
9.52 (3/8")
15.9 (5/8")

1400F
14000
16000
2000
45
52
9.52 (3/8")
15.9 (5/8")

Electric power supply: 220-240V~50Hz; All the refrigerant connections of the indoors units are flared
The performance refers to the following conditions:
measured at 1 m in semianechoic chamber
Cooling:
- Room air temperature 27 C D.B. ; 19 C W.B.
- External air temperature 35 C D.B.

Heating:
- Room air temperature 20 C D.B.
- External air temperature 7 C D.B. ; 6 C W.B.

MVA_W

MVA_F

MVA_C / CS / CB
MVA_D / DH

MVAM

MVA_FS

MVA220W
MVA280W
MVA360W
MVA450W
MVA500W
MVA560W
MVA630W
MVA710W
MVA220D
MVA250D
MVA280D
MVA320D
MVA360D
MVA400D
MVA450D
MVA500D
MVA560D
MVA630D
MVA710D
MVA800D
MVA900D
MVA1000D
MVA1120D
MVA1250D
MVA1400D
MVA560DH
MVA630DH
MVA710DH
MVA800DH
MVA900DH
MVA1000DH
MVA1120DH
MVA1250DH
MVA1400DH
MVA1600DH
MVA2240DH
MVA2800DH

A
(mm)
275
275
298
298
298
319
319
319
700
700
700
700
700
900
900
900
1100
1100
1100
1200
1340
1340
1340
1340
1340
1271
1271
1271
1271
1229
1229
1229
1229
1229
1340
1628
1628

B
C
Weight
(mm) (mm) (kg)
843
180
9.5
843
180
9.5
940
200
11
940
200
11
940
200
11
1008 221
13
1008 221
13
1008 221
13
615
200
22
615
200
22
615
200
22
615
200
22
615
200
22
615
200
27
615
200
27
615
200
27
615
200
31
615
200
31
615
200
31
655
260
40
655
260
46
655
260
46
655
260
46
655
260
47
655
260
47
558
268
35
558
268
35
558
268
35
558
268
35
775
290
47
775
290
47
775
290
47
775
290
47
775
290
47
750
350
60
869
454
115
869
454
115

*: Grid GL40S dimensions 670x670x50 mm - 3.5 kg;


**: Grid GL40 dimensions 950x950x65 mm - 7 kg;
***: Grid GL40B dimensions 1040x1040x65 mm - 7.5 kg;
Aermec reserves the right to make all the modifications deemed
necessary for improving the product, including technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577
www.aermec.com

A
(mm)
MVA220CS *
596
MVA280CS *
596
MVA360CS *
596
MVA450CS *
596
MVA500CS *
596
MVA560CS *
596
MVA280C **
840
MVA360C **
840
MVA450C **
840
MVA500C **
840
MVA560C **
840
MVA630C **
840
MVA710C **
840
MVA800C **
840
MVA900C **
840
MVA1000C **
840
MVA1120C **
840
MVA1250C **
840
MVA1400C **
840
MVA1600CB *** 910
MVA220FS
600
MVA280FS
600
MVA360FS
600
MVA450FS
600
MVA500FS
600
MVA280F
700
MVA360F
700
MVA500F
700
MVA630F
700
MVA710F
700
MVA900F
700
MVA1120F
700
MVA1250F
700
MVA1400F
700
Outdoor units:
MVAM2240T
1605
MVAM2800T
1605
MVAM3350T
1605
MVAM4000T
1605
MVAM4500T
1605

B
C
Weight
(mm) (mm) (kg)
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
596
240 20.5
840
190
25
840
190
25
840
190
25
840
190
25
840
240
30
840
240
30
840
240
30
840
240
30
840
320
35
840
320
35
840
320
35
840
320
35
840
320
35
910
293
45
700
215
16
700
215
16
700
215
16
700
215
16
700
215
16
1220 225
40
1220 225
40
1220 225
40
1420 245
50
1420 245
50
1700 245
50
1700 245
60
1700 245
60
1700 245
60
930
930
1340
1340
1340

765
765
765
765
765

225
225
285
360
360

471

Code: SMVAMUY.00 / 1503

Dimensional data (mm)

Smuffo

Dehumidifier Portable

R134a

Features
Available in 3 sizes of different capacities
Modern look and casing in plastic material
Easy to move from one room to another with
4 rotating wheels
Relative humidity setting between 80% and
35%
Visual display of the humidity setting and that
read in the room
Possibility to set continuous operation for
operation at maximum dehumidification
capacity

472

3 fan speed settings


Easy and immediate use unit mounted control
panel
Delay timer for starting/stopping (2h, 4h)
Possibility to discharge the condensate into
the bucket mounted in the unit or to
externally drain directly through the outlet
pipe on the side of the unit
If the condensate collection bucket is full the
dehumidifier will stop and light up the
relative indicator

Indicator lights to show the requirement to


clean the filter
Automatic defrost
Easy of the filter and the condensate
collection bucket cleaning and maintenance
Auto-diagnostic Function
Auto-Restart Function

Technical data
Mod
Dehumidification capacity 1
Sound pressure level (max/med/min)
Air flow rate (max/med/min)
Condensate bucket collection capacity
Power input 1
Current input 1
Nominal power input 2
Refrigerant
Refrigerant charge

[l/24h]
[dB(A)]
[m3/h]
[l]
[W]
[A]
[W]
[kg]

DMK12

DMK20

DMK24

12
43/41/39
150/120/100
4.9
250
1.1
330
R134a
0.09

20
45/43/41
150/130/115
4.9
380
1.7
480
R134a
0.20

24
47/45/43
190/170/145
4.9
390
1.7
500
R134a
0.24

Power supply = 230V ~ 50Hz


Sound pressure measured in a semi anechoic chamber, 1m from the front
1

Indoor air temperature

Tested according to EN-60335

30C d.b. ; 27C w.b.

Dimensions (mm)

523 mm

B
343 mm

Height
Width
Depth
Weight

A
B
C
[kg]

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

DMK12

DMK20

DMK24

523
343
270
12.5

523
343
270
14.5

523
343
270
15

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

Cod.: SDMKUY.00 / 1301

270Cmm

473

CWX

Water cooled condensing unit


Cooling only operation
Internal installation with capacity from 3.5 to 6.7kW

R410A

Accessory TL 3

Accessory PF

CWX

EXC

EWP

Plasmacluster

EWA_H

The internal units EWP and EWA_H are supplied with the ioniser lter PLASMACLUSTER.
Plasmacluster is capable of breaking down contaminants, decomposing the molecules.
By electrical discharges "Plasmacluster" causes the water molecules present in the air to be split into positive and negative ions. These
ions neutralise the molecules of gaseous contaminants achieving products normally present in clean air.
The result is in the air: nally you can breathe air cleaned, ionised and without bad odours.

Characteristics
Available in 3 versions of different capacities
The versions are manufactured with refrigerant
R410A (CWX1200, CWX1800, CWX2400)
Operates as cooling only with condensation by
water
CWX condensing unit with rotary compressor
EXC: internal unit with three speed centrifugal fan
with the possibility to modify the electrical connection to increase the available static pressure.
Mandatory accessory PF(wired panel) or TL3
(remote controller), required for the operation of the unit

474

EWA_H - EWP: internal unit with three speed tangential type fan.
Horizontally adjustable discharge louvres and
motorised deflector louvres, actioned by the
remote controller for vertically adjusting the supply air
Infra red remote controller with liquid crystal
display.
Extremely low noise operation
Microprocessor controller
Timer programmed delay start and stop
Programmes for cooling only, heating only, dehu-

midification, automatic operation (heating/cooling)


Washable filter easily removed and with anti
mould treatment
Flare type refrigerant connections
Refrigerant lines up to 15m
Vast range of accessories available for the internal
unit EXC

Technical data
CWX
Cooling capacity
Total power input
Total current input
Water use at 16C
Water use at 30-35C
Sound pressure
Refrigerant
Refrigerant connections
Refrigerant lines
EXC
Heating capacity (electric heater)
Condensate drain rate
EER
Energy efciency class
Current input (electric heater)
Heating capacity with water coil*
Internal unit air ow

Sound pressure
Refrigerant connections
EWA
Condensate drain rate
EER
Energy efciency class
Air flow

Sound pressure

Refrigerant connections
EWP
Condensate drain rate
Air flow

Sound pressure
Refrigerant connections

W
W
A
l/h
l/h
dB(A)

1200
3500
795
3.58
140
706
47.5

2400
6700
1940
1.4
345
1450
50.5

1/4
1/2
1/4
1/2

1800
5100
1370
6.34
235
1082
50.5
R410A
1/4
1/2
1/4
1/2

liquid
gas
liquid
gas

123
1650
1.4
7.2
3800
310
400
520
29.0
34.5
39.0
1/4
1/2

183
1950
1.78
3.72
A
8.5
5000
550
650
840
43
46.5
50
1/4
1/2

243
2200
2.3
3.45
B
9.6
6700
610
830
960
41
45
48
1/4
5/8

m3/h (min.)
m3/h (med.)
m3/h (max.)
dB(A) (min.)
dB(A) (med.)
dB(A) (max.)
liquid
gas

120 H
1.2
4.40
A
210
396
438
28
33
37
1/4
1/2

l/h
m3/h (min.)
m3/h(med.)
m3/h (max.)
dB(A) (min.)
dB(A) (med.)
dB(A) (max.)
liquid
gas

181 H
1.6
798
954
1068
37
42
45
1/4
1/2

W
l/h
W/W
A
W
(min.) m3/h
(med.) m3/h
(max.) m3/h
(min.) dB(A)
(med.) dB(A)
(max.) dB(A)
liquid
gas
l/h
W/W

1/4
5/8
1/4
5/8

Power supply = 230V ~ 50Hz


Performances relate to the following conditions:
Sound pressure measured in a semi-reverberant room of 85m3 and reverberation
time Tr = 0.5s
Sound pressure measured in an anechoic chamber at 1.3m distance and
directivity factor 4

Cooling:
- ambient air temperature 27C Db / 19C WB
- external air temperature 35C
- maximum speed

* = Apply the connection (1/2F - 5/8M) supplied loose with the condensing unit CWX 2400 to the refrigerant connections of unit EWP H

Accessories
Mandatory accessory PF or TL3 are required for
the operation of the unit
EXC:
PF: Control panel with ambient electronic
thermostat for wall mounting. It is a mandatory accessory since the EXC unit is shipped
without.
TL3: Infra red remote controller with liquid
crystal display for the control of all functions
Kit complete with recess mounted base. It is a
mandatory accessory since the EXC unit is
shipped without.
AMP: Hanging installation kit.
BC: Auxiliary condensate drain pan.
BV: 1 row hot water coil.

DSC4: Condensate pump for overcoming lift.


GA: Intake grille with fixed louvres.
GAF: Intake grille with fixed louvres and filter.
GM: Supply grille with adjustable louvres.
MA: Enclosure Alto.
MU: Enclosure Universale.
PA: Suction plenum in galvanised sheet steel,
complete with supply connections in plastic
for circular duct connections.
PC: Sheet steel panel for enclosing the rear
part of the unit.
PM: Discharge plenum in galvanised steel,
externally insulated, with supply connections
in plastic for circular duct connections.

RD: Discharge straight connection for ducting.


RDA: Suction straight connection for ducting.
RP: Discharge connection 90 for ducting.
RPA: Suction connection 90 for ducting.
RX: Shielded electric heater coil with safety
thermostat.
SE: External air manual damper.
SW: Sensor that permits unit operation only
with temperature above 35C.
VCF: Kit consisting of 3 way motorised valve,
connections and copper tubes.
ZX: Feet for floor mounting for models with
the accessory MA, or recess mounting.

475

Accessory compatibility

TL
PF
AMP

BC

BV
DSC
GA

GAF

GM

MA

MU

PA

PC

PM

RD

RDA

RP

RPA

RX

SE
SW
VCF

ZX

3 ***
***
4*
5**
6**
8
9
122
132
142
162
4
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
23
32
33
42
43
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
070
090
120
180
180 T
240
240 T
20X
30X
40X
80X
3
44
45
5
6
7
8

* = in combination with accessory MA

CWX 1200
EXC 123

****

CWX 1800
EXC 183

****

** = in combination with accessory MU

*** = Is a mandatory accessory in that the EXC unit is shipped without

**** = The VCF valve and the BC4 drain pan cannot be installed simultaneously on the same unit.

476

CWX 2400
EXC 243

****

Dimensional data (mm)


EXC 123 - 183
EXC
A
B
C
D
E
F
G
H
L
M
N
P
Weight (kg)

EXC 243

123
457
1043
216
891
453
41
101
74
260
144
49
973
26

183
457
1043
216
891
453
41
101
74
260
144
49
973
27

A
B
C
kg

181 H
325
1040
229
16

EWP
Height
Width
Depth
Weight

243
562
1182
216
1102
558
41
107
68
273
253
32
1122
37

EWP

EWAH
Height
Width
Depth
Weight

120 H
278
790
198
10

A
B
C
kg

CWX
Height
Width
Depth
Weight

A
B
C
kg

1200
450
470
260
35

1800
450
470
260
38

2400
570
470
260
49

CWX
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com

477

Cod.: SEXCUY.17 / 1503

EWAH

FW-R

Water-cooled air conditioners with capacities from 2.9 up to 4.0 kW

R410A

TL 3
Mandatory
accessory

FW-R series integrated system air conditioners are independent


appliances designed and built to create and maintain optimum room
comfort conditions.
Discreetly and elegantly styled, these remarkably quiet units are ideal
for installation in the home or commercial premises.
Equipped with a water-cooled condenser, FW-R appliances perform all
typical cooling, dehumidification, ventilation and air filtration functions
while offering particular benefits in terms of ease of application and
installation.

Suitable also for winter operation when equipped with an electric


heater or hot water coil; console air conditioners are able to provide
different microclimates within the same room because each appliance
can be adjusted independently; low running costs are assured by fast
arrival at the required room temperature because of the low thermal
inertia of the system; quiet operation and thermal efficiency are also
promoted by the heat and sound insulation of the compressor bay.
All appliances are factory assembled and individually tested.

Features
High efficiency rotary compressor
Compact size

Quiet operation
Automatic temperature adjustment

Reduced water consumption


Low electrical power consumption

Accessories
TL3 : Mandatory accessory, remote controller, BR: Armoured heating element with safety BVR: Single row hot water coil.
required for the operation of the unit
thermostat.

FW
TL 3
BR 26
BVR 1

478

Compatibility of accessories
130R
160R

Technical data
Mod.
Cooling capacity
Energy Efciency Class
EER
Humidity removed
Input power
Input current
Heating capacity with water coil (BVR1)
Water ow rate (BVR1)
Pressure drops (BVR1)
Heating capacity electric coil (BR26)
Fans
Air ow rate

Fans speed
Sound pressure
Water consumption at 30-35C
Condenser pressure drops
Refrigerant charge R410A
Input nominal power consumption *
Nominal imput current *
Input current
Water connections

FW
W (max.)

l/h
W
A
W
l/h
kPa
W
n.
m3/h (max.)
m3/h (med.)
m3/h (min.)
g/m (max.)
g/m (med.)
g/m (min.)
dB (A)
l/h
kPa
g
W
A
A

130R
2900
A
4.08
1.78
710
3.55
4350
600
12,6
1200
2
470
390
270
800
660
500
44
586
22
750
1120
4.97
18
1/2F

160R
4000
A
4.65
1.78
860
4.02
5200
600
12,6
1200
2
690
525
375
1140
885
665
47,5
804
40
830
1500
6.65
32
1/2F

Power supply = 230V ~ 50Hz.


Sound pressure measured in an 85 m3 semi-reverberant test chamber
with reverberation time Tr = 0.5s.
* In accordance with UNI EN-60335
Data declared in accordance with EN-14511
Cooling
- Room air temperature 27C B.S. ; 19C B.U.
- Entering water temperature 30C
- Leaving water temperature 35C
- Max speed

Heating (BVR1) :
- Room air temperature 20C
- Entering water temperature 70C
- Max speed

Height
Width
Depth
Weight

A
B
C
Kg

Aermec reserves the right to make all modification deemed


necessary for improving the product at any time with any
modification of technical data.

FW 130 R
723
1121
242
63

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577
www.aermec.com

Cod.: SFWRUY.06 / 1303

Dimensions (mm)

FW 160 R
723
1121
242
67

479

DISTRIBUTORS / DISTRIBUTEURS
ALBANIA
AERMEK ALBANIA SH.P.K. - Bul. Zhan DArk Kulla 4 - TIRANA- Ph. +355 4 2224339 - Fax. +355 4 2224339 - tltsystem@albmail.com
ALGERIA
AIRMEC ALGERIE - 312 Avenue Hamid Kebladj - Hammamet - Ph. + 213 21 957 883 - Fax + 213 21 958 036 - airmec_algerie@yahoo.fr
ANGOLA
CEST COMRCIO E INDSTRIA, LDA Rua do Ex. Matadouro, s/n Morro Bento Luanda - Tel. +244 222 469 105 Fax +244 222 469 024 geral.angola@cest.pt
ARGENTINA
TROX ARGENTINA SA. - Timbo 2610 - Parque Industrial Burzaco - Buenos Aires - Ph. +54 1142335676 - Fax +54 91155234803 - fernando.cani@trox-latinamerica.com
AUSTRALIA
COSAIR PRODUCTS PTY LTD - Unit 10, 35 Birch Street - Condell Park NSW 2200- Ph. +61 297964668 - Fax +61 297964669 - mcosgrove@cosair.com.au
AUSTRIA
AERSYS GMBH - Anton-Freunschlag Gasse 72 - 1230 Wien - Ph. +431 6991967 - office@aersys.at
AZERBAIJAN
NEP ENGINEERING - Nizami 86/7 - Baku - Ph./Fax. +99 412 4934560 - nep@nep.az - perviz@ozulinsaat.com - k.secher@nep.com.tr
BELGIUM
ENERWIN S.P.R.L. - Avenue Vesale 20 B - 1300 WAVRE - Tl. +32 10 232650 - Fax +32 10 812608 - info@enerwin-aermec.be
BRASIL
TROX DO BRASIL - Rua Cyro Correia Pereira 300 - CIC - Curitiba - Ph. +55 413316-8418 - Fax +55 413316-8490 - fernando.cani@trox-latinamerica.com
BOLIVIA
CONSULCAD - Av. Roca Y Coronado 2868 - Santa Cruz - Tel. +591 1 351 4555 - proyectos@consulcadsrl.com
BOSNIA AND HERZEGOVINA
TAURUS D.O.O.- UL. Medresa BR. 4 - 71270 FOJNICA - Ph. +386 40298682 - Fax +387 33524738 - marko.moldovan@gmail.com
BIELORUSSIA
AEPMEK-BEL Ltd. - 115, Mayakovskogo str. - Minsk - Ph. 375 295018323 - Tornado-ASL@yandex.ru
BULGARIA
ATARO CLIMA EOOD - 272 Vasil Levski str. - Plovdiv - Ph. +359 32 906 906 - Fax +359 32 906 900 - ataro@ataro.bg
RATOLA INZHENERING - 51, General Skobelev Blvd. - 1606 Sofia - Ph. +359 2 9691031 - Fax +359 2 9691020 - office@ratolabg.com
CANADA
MITS AIR CONDITIONING Inc. - 1608 Bonhill Road - L5T 1B451 Mississauga ONTARIO - Ph. +905 564 2221- Fax + 905 564 2205 - jchaters@mitsair.com
CHILE
GAPPS - Camino a Melipilla 2259 - PENAFLOR - Santiago - Tel. +56 9 54092803
CROATIA
MARITERM d.o.o. - Drazice 123D, Zamet - 51 000 Rijeka - Ph. +385 51 815010 - Fax +385 51 815011 - mariterm@mariterm.hr
CYPRUS
ROYAL ENGINEERING CO. LTD - 6 Trachona Str. - Dhali Industrial Area - 1662 Nicosia - P.O. Box 20689 - Ph. +357 22612199 Fax +357 22610272 - royaleng@cytanet.com.cy
CZECH REPUBLIC
COMPLETE CZ spol. s.r.o. - Legerova 1853/22 - Praha 2 - Ph. +420 246 030029 - Fax +420 246 030032 - info@completecz.cz
DENMARK
H. JESSEN JURGENSEN A/S - Tempovej 18-22 - 2750 Ballerup - Ph. +45 70 270607 - Fax +45 70 263405 - jeo@hjj.dk
EGYPT
EBIARY ENGINEERING COMPANY- 1-B, Makraam Ebeed St. - Nasr City - CAIRO - Mob. +20101350232 - Fax +202 22743550 - ebiarydct@yahoo.com
ENGLAND
AERMEC UK LIMITED - 288 Bishopsgate - London - EC2M 4QP - Ph. +44 0203 008 5940 - Fax +44 0203 008 5941 - uksales@aermec.co.uk
ESTONIA
NORDIC CLIMA PLC - Peterburi tee 46, Tallinn 11415 Estonia - Ph. +372 652 5005 - info@nordicclima.com
FINLAND
HUURRE FINLAND - Taivaltie 5 - 01610 Vantaa - Ph. +358 20 5555897- Jari.Vanhala@huurre.com
FRANCE
AERMEC SAS - PARC VISIONIS II - Rue du Developpement - 01090 GUEREINS - Tl. +33 04 74090038 - Fax +33 4 74090988 - info@aermec.fr
AERMEC SAS - AGENCE SILLON ALPIN - 7, Chemin des Roquevillard - 73160 Cognin - Tl. +33 04 85013570 - Fax +33 04 74090988
jerome.dubouchet@aermec.fr
AERMEC SAS - Ile de France - 80 Avenue du Gnral De Gaulle - 91170 Viry Chatillon - Tl. +33 1 60478348 - Fax +33 1 69436368
gianni.delfabbro@aermec.fr
DIMENA SARL - 88 Rue Du Moulineau - 33320 Eysines - Tl. +33-5-57876429 - Fax +33-5-56798900 - contact@dimena.fr
DIMENA - 6 Rue Maurice Hurel - Parc de la plaine - 31500 Toulouse - kriva@dimena.fr
S.TE FRANCE CLIM - 41 rue Pierre Smard - 57300 Hagondange - Tl. +33 3 87517505 - Fax +33 3 87517514 - france.clim@laposte.net
PHOENIX CLIMATISATION - 8, Rue de Paris - 92190 Meudon - Tl. +33 01 41144191 - Fax +33 01 41145221 - rponcet@phoenix-climatisation.fr
T.C.A. - Avenue des Maurettes - 06270 Villeneuve Loubet - Tl. +33 4 92133666 - Fax +33 4 93208304 - tca06@tca.fr
T.C.A. - 19 Rue M. Basti Z.I. de la Lauze - 34430 St Jean De Vedas - Tl. +33 4 67473690 - Fax +33 4 67479851 - tca34@tca.fr
T.C.A. - 213 route de la Valentine aux 3 lucs -13011 Marseille - Tl. +33 4 91191919 - Fax +33 467479851 - tca13@tca.fr
GEORGIA
Saga Impex Ltd.- 2-4-6-8-10 Chachava Street, 0159 Tbilisi - Georgia - Ph. +995 32 540717/27/37/47 - Fax +995 32 541727 - shalva@sagaimpex.ge
GERMANY
AERMEC GmbH - Im Tal 10 - 87669 Rieden Am Forggensee - Tel. +49 8362 300600 - Fax +49 8362 3006060 - info@aermec.de
NOVATHERM KLIMAGERTE GmbH - Am Gierath 4 - 40885 Ratingen - Tel. +49 2102 91000 - Fax +49 2102 910010 - ratingen@novatherm.de
NOVATHERM KLIMAGERTE GmbH - Dieselstrasse 40 - 30827 Garbsen-Berenbostel - Tel. +49 5131 49670 - Fax +49 5131 496767 - hannover@novatherm.de
GREECE
CALDA ENERGY S.A.I.C. -100 Tatoiou Str, Metamorfossi -14452 Athens - Ph/Fax +30 210 28 43 - Fax + 30 210 28 43 - calda@otenet.gr
HOLLAND
HOLLAND CONDITIONING B.V. - Tielenstraat 19 - 5145 RC Waalwijk - Ph. +31 416 650075 - Fax +31 416 650586 - hc-info@hcgroep.com
HUNGARY
OKTOKLIMA - Kirlyok tja 27 -1039 Budapest - Ph. +36 1 4332360 - Fax +36 1 2403617 - oktoklima@oktoklima.hu
IRAN
PIONEER MIDDLE EAST CO. - 643, West Sanabad Ave. West - Mashad - Ph. +98 51 38457722/5 - Fax +98 51 38411627 - eng@middleasthvac.com
IRELAND
European Industrial Chillers Limited - Unit 74 Dunboyne Business Park - Dunboyne Co. Meath - Ph. +353 01 8255155 - Fax +353 01 8255188
ISRAEL
Tadiran Energy Ltd. - 1 Alexander Yanai St., Petach Tikva, Israel - Tel. +972-3-9283422 - Fax +972-3-9283357 - Aermec@tadiran-group.co.il
NORTH IRELAND
Please contact Aermec Spa - Via Roma, 996 - 37040 Bevilacqua (VR) - Ph. +39 0442 633111 - Fax +39 0442 93577 - sales@aermec.com

VERTRIEBSPARTNER / DISTRIBUIDORES
KAZAKHSTAN
AEPMEK KAZAKHSTAN - Samal-2, 59, Blok B, office 19 - 050040 Almaty - Ph. +77272668648 - info@aermek.kz
AEPMEK KAZAKHSTAN - Business Center Ansar 3rd floor, office VP Siganak Street 25, - 010000 Astana - Ph. +77172550748 - info@aermek.kz
KOREA
GEOPROTEK CO., Ltd. - Rm 1111, Samsung Cheil Build. - Yoksam-Dong Kangnam-Gu - Seoul - Ph. 02 527 3608-9 - Fax 02-527-3610 - geoprotek@daum.net
KOSOVO
N.SH.M. MONTKOMERCE GZ - RR. Orize 6 H2/11 - Gyakove - Ph. +37 744122804 - gezimzeka4@yahoo.com
INSTALL ENGINEERING S.H.P.K. - Kroi I Bardhe nr. 12 - Prishtine- Ph. +381 38 540 977 - info@install-ks.com
LIBYA
JSD Engineering - APOLLONOS str 26 - P.O. BOX: 21865 - 1514 NICOSIA CYPRUS - Ph. +30210-6894 627/+30210-6894 637
Fax +30210-6894 439 - leadair@ath.forthnet.gr - leadairsa@gmail.com
LITHUANIA
NIT Ltd - Savanoriu-Pr 151- 03150 Vilnius - Ph. +370 5 2728552 - Fax +370 5 2728559 - andrius@nit.lt
LUXEMBOURG
CLIMAX LUXEMBOURG SARL - 7 Rue Lankelz - L 4205 Esch Sur Alzette - G.D. of Luxembourg - Ph. +352 26 176615 - Fax +352 26 176625 - info@climax.lu
MACEDONIA
D.O.O. EUROTERM - UL. Sotka Georgieski Br. 63 - 7500 PRILEP - Ph. +389 48419415 - Fax +389 48422981 - info@euroterm.com.mk
MALTA
ENGENUITY LTD - 8 Triq Tal HIas - Qormi Qrm5011 - Ph. +356 21490957/8 - Fax +356 21490964 - alan.abela@engenuity.com.mt
MOLDOVA
SC LERAI GROUP - Via Bulgara, 18 - Chisinau MD-2001 - Ph. +373 22 224238 - Fax +373 22 233024 - info@lerai.md
MOROCCO
ECOTHERM SARL - 67, Rue du Lieutenant MAHROUD ex Rue Chevalier BAYARD - Casablanca 20300 - Tl- +212 522 243300
Fax +212 522 243302 - contact@ecotherm.ma
NEW ZEALAND
Black Diamond Technologies Ltd- 1 Parliament Street, Lower Hutt - 3243 Hamilton - Ph. +64 78392705 - Fax +64 78344212 - jimb@bdt.co.nz
NORWAY
NOVEMA KULDE AS - Marenlundveien 5 - 2020 Skedsmokorset - Ph. +4769367190 - Fax +4769367191 - trond.kristensen@novemakulde.no
NOVEMA KULDE AS - Stabburveien 8 -1601 Fredrikstad - Ph. +47 69 367190 - Fax +47 69 367191 - espen.spondalen@novemakulde.no
NOVEMA KULDE AS - J Brochs gate 12 inng B - 5006 Bergen - Ph. +47 55 348675 Fax +47 55 348675 - bjorn.vassbotten@novemakulde.no
NOVEMA KULDE AS - Sorgenfrivn 9 - 7037 Trondheim - Ph. +47 73 820890 - Fax +47 55348675 - jon.lines@novemakulde.no
PERU'
AIRLAN - Condominio Town Houses - Calle Schell 644, Interior N 128 - Miraflores, 18 - Lima - Tel. +511 4450833 - Fax +511 4450833 - manuelgrana@airlan.es
POLAND
Aermec Polska Sp. z o.o. -Ul. Pulawska 405 - 02-801 Warszawa - Ph. +48 22 463 43 43 - aermec@aemec.pl
PORTUGAL
CEST COMRCIO E INDSTRIA, LDA Av. Almirante Gago Coutinho - Ouressa Parque - Arm. 13, 2725-322 Mem Martins
Tel. +351 219253330 Fax +351 219253338 geral@cest.pt
RUMANIA
AIRMEC ROMANIA S.RL. - 29 lezeru Street, Sector 1 - Bucharest - Ph. +40 21 550866589 - Fax +40 21 3260973 - airmec@adslexpress.ro
RUSSIA
AERMEC Spa - Rep. Office Business Center Capital Plaza, 4 Lesnoy Pereulok - office 455 - 125047 Moscow - Ph. +7 495 6638044 - m.l@aermec.com
SERBIA & MONTENEGRO
AKTING DOO - Jurija Gagarina, 153/32 -11070 Novi Beograd - Ph. +381 113187383 - Fax +381 113187387 - akting@eunet.rs
SLOVAKIA
KLIMA TEAM s.r.o. - Trnavska 63 - 82101 Bratislava - Ph. +421 2 43293969 - Fax +421 2 43420079 - mail@klimateam.sk
SLOVENIA
BOSSPLAST D.O.O. - Pod Jelsami 5 -1290 Grosuplje - Ph. +386 1781 0550/5 - Fax +386 1781 0560 - jernej.rode@bossplast.com
SOUTH AFRICA
APOLLO AIR CC - Unit 4, 10 Cabernet Str - Saxenburg Park, Kuilsriver - 7562 Cape Town - Ph. +27 21 9057979 - Fax +27 21 9057976 - carlo@apolloair.co.za
SPAIN
AIRLAN S.A. - Ribera de Deusto 70 - 48014 Bilbao - Tel. +34 94 4760139 - Fax +34 94 4752402 - rcoteron@airlan.es
AIRLAN - Pol. lnd. La Grela C/Ermita 48 -15008 La Coruna - Tel. +34 981 288209 - Fax +34 981 286503
AIRLAN - C/Arganda 18 - 28005 Madrid - Tel. +34 91 4732765 - Fax +34 91 4732581
AIRLAN - Avda Meridiana 350 4A - 08020 Barcelona - Tel. +34 93 278 06 20 - Fax +34 93 278 02 24
AIRLAN - C/ Acueducto 24 - Edif. Dos Hermanas Isla Edificio 2, Pl 1, Mod. 9 - 41703 Pol. Ind. Ctra. De la Isla, Sevilla (Sevilla) - Tel. 955 540 612 - Fax 901 706 015
AIRLAN - Pol. lnd. Son Castello C/Teixidors 30, Nave 5 - 07004 Palma De Mallorca - Tel. +34 971 706500 - Fax +34 971 706372
AIRLAN - C/Los Bimbaches 13 - 38007 Santa Cruz de Tenerife (Isole Canarie) - Tel.+34 922 21 4563 - Fax +34 922 7985
SYRIA
SINJAB TRADING EST - Murshe Khater st. PO BOX 5358 - 5073 Damascus - Ph. +963 11 4424541 - Fax 963-11-4412862 - sinjabest@gmail.com
SWEDEN
KYLMA AB - Box 8213 -163 08 SPNGA, - Ph. +46 8 59890805 - Fax +46 8 59890891 - Mikael.Magnusson@kylma.se
AIRCOIL AB - Angsvagen 22 - 67232 ARJNG - Ph. +46 573 711045 - Fax. +46 573 711811 - info@aircoil.se
SWITZERLAND
TCA THERMOCLIMA AG - Piccardstr. 13 - 9015 St. Gallen - Ph. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch
TCA THERMOCLIMA AG - Gewerbestr. 10 - 4528 Zuchwil - Ph. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch
TCA THERMOCLIMA SA - Av. Boveresses 52 - 1010 Lausanne - Ph. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch
KATALTHERM SERVICE S.A. - Via alla Gerra, Cp 54 - 6930 Bedano - Ph. +41 91 935 22 22 - Fax +41 91 935 22 24 - katalthermservice@ticino.com
TUNISIA
CODIFET S.A.R.L. - 7 Rue de la Chimie Z.I. SIDI REZIG - 2033 Megrine - Tl. +216 71 433035 - Fax +216 71 433239 - codifet@planet.tn
TURKEY
AIR TRADE CENTER - Ibrahim Karaoglanoglu Caddesi No: 101 - 34418 Seyrantepe / Istanbul - Ph. 90(0)2122834510 - Fax 90(0)2122783964
atc.turkey@airtradecentre.com
UKRAINE
AERMEK UKRAINE LLC, - Vorovskogo Str., build. 37/14 off. 304 - 01054 Kyiv 054 - Ph. +38 044 229 74 47 - Fax +38044 390 73-47 - apo@aermec.com.ua
URUGUAY
CLIMATIZACION INTEGRAL LTDA - Pedro Cosio 2064 - 11400 Montevideo - Tel. +598 26136565 - Fax +598 26136565 - pgiosa@climatizacion.com.uy
UNITED STATES
MITS AIR CONDITIONING Inc. - 1608 Bonhill Road. - CA L5T 1C7 Mississauga (Canada) - Ph. 1-888-567-2227 - Fax 905-564-2221 - help@aermec.us
UNITED ARAB EMIRATES
PROGEN General Trading L.L.C - 6th Floor, Concord Tower - Dubai Media City, P.O. Box 500 434 - Dubai - Tel. +971 4 454 9823 - Fax +971 4 454 2310
auof@progentrd.com

Cod.(16:@