ON LOAD
TAP CHANGERS
OFF CIRCUIT
TAP SWITCHES
CPRI TESTED
PGCIL APPROVED
Strategic Locations.
Well laid our Shop Floors, with adequate Material Handling Equipment.
ABOUT US
Widest Range - Off Circuit Tap Switches & On Load Tap Changers - under
one group.
Over one hundred registered Vendors, including units with ultra modern
machining facilities.
Voltage Class
Current Rating
No. of Taps
No. of Phase
L Dimensions (mm)
Connection
Mounting
Operation
Cooling Media
:
:
:
:
:
:
:
:
:
24 kV & 36 kV
Upto 100 Amps
05 & 07
Upto 3 Phase
70, 100, 130, 150, 200
Bridge Type
Cover Mounting
Manual
Transformer Oil
Voltage Class
Current Rating
No. of Taps
No. of Phase / Deck
Type of Connection
Operation
Cooling Media
:
:
:
:
:
:
:
Upto 47 kV
Upto 600 Amps.
Upto 13
03 / 06 / 09 / 12
Bridge (Ring) Type
Manual
Transformer Oil
Voltage Class
Current Rating
No. of Taps
No. of Phase / Deck
Type of Connection
Type of Contacts
Operation
Cooling Media
:
:
:
:
:
:
:
:
Upto 33 kV
Upto 400 Amps.
09 Posn.
Upto 06
Bridge
Snap Action & Push Pull
Manual/motorised (snap Action).
Air
PRODUCTS
CUSTOMERS
SELECTOR / BRIDGE
Voltage Class
Current Rating
No. of Taps
No. of Phase / Decks
Type of Connection
Mounting
:
:
:
:
:
:
Operation
Cooling Media
Upto 220 kV
Upto 5000 Amps.
Upto 72
Upto 12
Bridge / Selector / Reversing / Coarse & Fine
Horizontal, Handle/drive On Side Wall
Horizontal, Handle On Top Cover
Vertical, Handle/drive On Top Side Wall
Vertical, Handle/drive On Bottom Side Wall
Vertical, Handle On Top Cover
Bell Mounted
: Motorised / Manual
: Transformer Oil
Voltage Class
Current Rating
No. of Taps
No. of Phase
Type of Connection
Cooling Media
:
:
:
:
:
:
Control Voltage
Motor
Switching Time
Time for Tap Change
:
:
:
:
230 V
230 V, 3 Phase, 0.18 or 0.36 kW.
02 Seconds (Approx)
07 Second (Approx)
Voltage Class
Current Rating
No. of Taps
No. of Pole
Type of Contacts
Operation
Cooling Media
:
:
:
:
:
:
:
Upto 33 kV
Upto 3500 Amps.
ON / OFF
Upto 04
Snap Action
Manual
Transformer Oil
Voltage Class
Current Rating
No. of Pole
No. of Position
Operation
Cooling Media
:
:
:
:
:
:
Upto 1.1 kV
500 / 1000 / 2000 Amps Models
01
ON / OFF
Manual
Air
Customer List indicative only, not exhaustive. All logos belong to their respective owners.
PRODUCTS
Voltage Class
Current Rating
No. of Phase
Mounting
Operation
Cooling Media
:
:
:
:
Upto 220 kV
Upto 5000 Amps.
03
Horizontal, Handle/Drive on
Side Wall or Top Cover
Vertical, Handle/Drive on Top / Bottom
of Side Wall or on Top Cover
Bell mounted
: Motorised / Manual
: Transformer Oil
PRODUCTS
T - Type
EU Type
CONTACT US
Various options like Limit Switch, Dial Switch, Operation Counter, Electro Magnetic Latch, Multiple Unit Synchronisation, etc. available.
For:
l
For:
l
Knife Switches
Contact
Contact
T K Thankappan | Chairman