INSTALLATION INSTRUCTIONS

Liquid Level Switch for ORCAIIA - PN 3500103

INSTALLATION INSTRUCTIONS

Liquid Level Switch for ORCAIIA - PN 3500103


SPECIFICATIONS
L-30N ( Noryl PPO)
For use in water, acids, bases, inorganic solutions,
sewage, contaminated water
Wetted Surfaces
Noryl Engineering Plastic (PPO), 316 Stainless
Steel, EPDM (Hypalon optional)
Nominal working temperature & pressure
Temperature (oF) 200 Max
Pressure (PSIG) 75 Operating
100 Max Non-operating

L-30R (Fortron PPS)(Broad Chemical Spectrum)


For use in acids, bases, inorganic solutions, alcohols,
ketones, chlorinated organics, esters, ether, hydrocarbons,
nitrites, phenols...
Wetted Surfaces
Fortron Engineering Plastic (PPS), 316 stainless steel,
Viton
Nominal working temperature & pressure
Temperature (oF) 200 Max
Pressure (PSIG) 75 Operating
100 Max Non-operating

Specifications for Models L-30N & L-30R


Working Fluid Spec. Gravity - 0.8 min.
Electrical Switch Characteristics
SPDT UL and CSA listed
15 AMP @ 1/2 HP; 125/250 VAC
1/2 AMP @ 125 VDC, 1/4 AMP @ 250 VDC
5 AMP 125 VAC (Tungsten lamp load)
10,000,000 operations median.
SPDT-Dry Circuit
Gold Cross Bar Contacts for Computer/PLC Interface
1.0 AMP or less 5-24 VAC/DC (UL & CSA listed)
Liquid Level Change to Activate Switch:
~1/4" all models
Weight: 1/2 lb

Option No. 1 Sample Part Numbers:


Basic Model #
Horizontal or Vertical
& Body Material

Grommet Size

Input Power Cable


Interface Options

Option No. 2 Sample Part Numbers:


Basic Model #
Horizontal or Vertical
& Body Material

L-30N / A
L-30R / AA
L-30RV / B
Body Material:
Horizontal or
Vertical Mount
N or R

L-30N V / F
L-30R / F
L-30RV / F

Grommet
Size

Cable
O.D.

Grommet
Size

Cable
O.D.

A
AA

0.25 in.
0.30 in.

B
C

0.37 in.
0.50 in.

1/2 Flexible
Conduit Fitting

INSTALLATION INSTRUCTIONS

Liquid Level Switch for ORCAIIA - PN 3500103


INSTALLATION & OPERATING INSTRUCTIONS

Installation:
The L-30 Liquid Level Switch is supplied with a 1-1/2 or 1-1/4 x 1 bushing threaded in place with 2 to 3 wraps of teflon
tape, which must be intact or renewed if bushing and switch are separated before assembly in tank. Care must be
exercised when threading the bushing into plastic or metal fittings. Apply a minimum of 2 to a maximum of 3 wraps of
teflon tape to threds of bushing - this is especially important if unit is to be used in metal fittings where coarse METAL
THREADS could gall plastic if not lubricated. The plastic bushing CAN BE CRACKED if the main body of the flow switch
is tightened into it FIRST. Cracking will not occur if the bushing is FIRST tightened into the pipe or tank fitting and THEN
the L-30 body is tightened into the bushing.
Thus:
1). Teflon tape thread and tighten plastic bushing into pipe or tank fitting.
2). Teflon tape thread and tighten L-30 switch into PLASTIC bushing by applying wrench to hexagon section.
Repeat steps 1 and 2 until ARROW on body points to UPWARD and threas are leak tight.
Plumbers tools such as pipe wrenches are not recommended. If possible, use a Rigid type wrench where the smooth
jaws closely fit the hexagon section.

Electrical Wiring:
Step 1: Remove gland nut, grommet and switch cover.
Step 2: Strip outer jacket of electrical cord back approximately 1-1/4" inches. Strip insulation from individual
conductors back approximately 1/4 inch.
Step 3: Slip on terminals are supplied with each switch. Remove from switch terminals and crimp on or solder to
electrical leads.
Step 4: Feed electrical cable through gland nut, grommet and switch cover as shown.

Step 5: Apply slip on terminals to appropriate contacts of microswitch. Slide cover down cable and fasten to body of
switch with 4 screws provided. Slide grommet down cable until outer jacket is level with small end of grommet
per illustration page 2.Push grommet into tapered end of cover. Hold cable jacket to prevent rotation and thread
gland nut firmly onto cover.
Fig. 1: Wiring schematic for power applied to
load when liquid level is less than set point
(power to load interrupted when level
increases to above set point).

Fig 2: Wiring schematic for power applied to


load when liquid level is greater than set point
(power to load interrupted when level
decreases to below set point).
Increasing Liquid Level moves actuator in
direction shown.

Decreasing Liquid Level moves actuator in


direction shown.

Micro switch actuation point may be monitored by an audible click or with an OHM meter before connecting line power to
the terminal strip or by monitoring the voltage supplied to the load through the micro switch.

INSTALLATION INSTRUCTIONS
Liquid Level Switch for ORCAIIA - PN 3500103

INSTALLATION INSTRUCTIONS
Liquid Level Switch for ORCAIIA - PN 3500103

No.

Part Name

Qty.

Part No.

No.

Part Name

Qty.

Part No.

Strain Relief Nut

60127

12

Washer

311-W

Grommet #A (Optional)

10440

13

Washer

301-W

#AA (Optional)

10441

14

Body (Assembly only)

65203

#B (Optional)

10442

Clamp Ring (Sonically


Welded)

65102

#C (Optional)

10443

Bushing Reducer (Optional)

65204

Bushing Reducer (Optional)

65205

Feed Thru Shaft (Assembly


Only)

65103

15

Cover-Male (Optional)

60125

Cover-Female
(Optional)

60126

Screw

109-S

A) Seal Shaft

65104

Microswitch

20103

B) Diaphragm

65105

Brackets

65401

C) Diaphragm Washer

65106

Terminals

706-T

D) Pivot Pin

65107

Screw

133-S

E) Cross Pin

65108

10

Screw

116-S

Drag Disk Arm


#2-B (Optional)

65208

11

Nut

219-N

65402

65601

16

17

#45% (Optional)
18

19

Float (Noryl) (Optional)

65602

20

Screw

123-S

21

O-Ring

65110