I N S TA L L AT I O N
Page 1
A N
ThermaSkirt
E C O
REVOLUTION
IN
ROOM
H E AT I N G
These instructions are intended as a guide only. Your installation & design may vary - if in doubt ask for help.
DiscreteHeat Co. Ltd. accept no liability for any errors or omissions.
If you have any tips or suggestions e-mail them to: toptips@discreteheat.co.uk
TOOLS YOU WILL NEED:
A suitable metal cutting saw, preferably a chop saw (only if cutting lengths on site) / A DiscreteHeat rotary de-burring tool / An accurate
quality tape measure (Stanley, DeWalt etc.) / String line and chalk or laser level / A Stanley knife and/or plasterboard saw / Power drill
with hammer action / Power driver / Size 10 screws (50-100mm) / Plastic or timber faced mallet / Rawlplugs and\or plasterboard fixings /
Pipe cutting tool (10mm/15mm/16mm) / Various push fit connectors / Your plan and cutting list (if purchased as a room kit).
THE SAME DIMENSIONS AND SPACINGS APPLY TO ANTI-CLOCKWISE INSTALLATIONS.
ALL EXAMPLES SHOWN ARE CLOCKWISE INSTALLATIONS.
.
1.
REGENCY OG
(8in / 200mm)
Remember to allow
for carpet or tiles if
NOT Finished Floor Level
URBAN LT
(6in / 150mm)
120mm
CLASSIC TS
(6in / 150mm)
DECO PR
(4.5in / 115mm)
FEED
15/16mm
FEED
15/16mm
100mm
RETURN
15/16mm
FEED
15/16mm
100mm
RETURN
15/16mm
RETURN
15/16mm
45mm
45mm
FEED
15/16mm
130mm
65mm
90mm
75mm
35mm
35mm
RETURN Feed and Return pipes tight to wall
Relieve plaster for fittings.
15/16mm
FINISHED FLOOR LEVEL
12
6
SINGLE TRV
CLOCKWISE SHOWN
Relieve plasterwork
100mm x 100mm to a depth of 5mm
(See template p.7)
120mm
BI-DIRECTIONAL TRV
Relieve plasterwork
150mm x 100mm to a depth of 5mm
(See template p.7)
150mm
100mm
130mm
65mm
FEED
(TRV VALVE)
FEED
(TRV VALVE)
Relieve plaster/
surface finish to a
120mm
to allow for
Tectite fittings
60mm
RETURN
(LOCKSHIELD
VALVE)
95mm
75mm
Feed
15mm
(16mm to order)
Return
15mm
(16mm to order)
45mm
RETURN
(LOCKSHIELD
VALVE)
90mm
WALL
FLOOR
WALL
FLOOR
TM
I N S TA L L AT I O N
Page 2
40mm
120mm
RF
L1
50mm
L9
20mm
= (L1 -160mm)
= (L2 -40mm)
= (L9 -150mm)
= (L3 -20mm)
100mm
Archway,
patio, door
obstruction,
etc.
CLOCKWISE
SYSTEM
SHOWN
(Threshold Kit)
24 TPI minimum
40mm
L3
20mm
= (L4 -5mm)
L4
20mm
L5
100mm
L8
L2
20mm
= (L5 -20mm)
= (L8 -120mm)
= (L6 -60mm)
= (L7 -60mm)
20mm
40mm
L7
40mm
L6
20mm
40mm
20mm
120mm (5")
TRV Feed/return
0~3mm (0.0")
Internal corner
External corner
100mm (4")
50mm (2")
Return manifold
50-55mm (2-2.16")
50-55mm
(2-2.16")
Odd angle - internal
20mm (0.8")
115mm (min)
Door architrave kit
Deburring tool
(Part No. STOOL)
Bell Mouth
deburr
DEBURR!
Keep parallel
x10
TM
3.
I N S TA L L AT I O N
Page 3
M O U N T I N G C H A N N E L - LT A N D O G P R O F I L E O N LY
?
cil
Pen
Lin
CL
STRING LINE
& CHALK
CL
85mm
60mm
Push in
Chalk Line
Chalk Line
90
Click down
100mm
from skirting
URBAN LT/
CLASSIC TS
REGENCY OG
600 ~ 1,000mm
5mm
DECO PR
Minimum active
length = 55mm (2.16")
Check greased!