Sie sind auf Seite 1von 4

VDR 4340 - Voyage Data Recorder

S-VDR 4330 - Simplified Voyage Data Recorder

The VDR is designed for interfacing all


common bridge Systems and ship
sensors. Analogue and digital signal
inputs can be easy adapted to specific
ship requirements.
The VDR is able to record up to 4 radars.
For downloading of data s a USB
memory stick is preinstalled. As an
option, a removable harddisk can be
fitted for long time data storage.
The VDR 4340 and the SVDR 4330 are
manufactured on the same hardwareand software components.

VDR Features
Easy to install

- Compact, lightweight unit, easy to


move and install
- Easy and convenient system
configuration and commissioning
by client terminal computer
Low hardware cost
High reliability and stability
- With embedded operating system
on flash disk, no harddisk failure

Flexible and extendible

- Easy to expand interfaces through


adoption of USB cascade components
- Different customers requirements
satisfied through optional components and modules
The VDR meets all requirements of the
IMO resolution 861(20) and the performance test standards of IEC 61996
and has EC Type Approval.

VDR 4340 / S-VDR 4330

Remote System Control


Unit (Optional)

Microphones
(indoor/outdoor)

UPS Power Supply


PSU

Protected Data Unit


PDU

Data Aquisition Unit


(Optional)

Playback Station
(Optional)

Main Unit
MU
Float Free Data Unit
(Optional)

Input Data from systems

Input
Date and time
Ships position
Speed
Heading
Bridge audio
Communications audio
Radar data
AIS - (radar alternative)
Main alarms (IMO mandatory bridge alarms)
Rudder order and response
Engine order and response
Hull openings (doors) status
Watertight and fire doors status
Acceleration and hull stresses (if fitted)
Wind speed and direction
Echo sounder

VDR

S-VDR

X
X
X
X
X
X
X

X
X
X
X
X
X
X
If no radar interface available

X
X
X
X
X
X
X
X

If IEC 61162 interface is available

Technical Specification /Equipment List


Technical Specification
Main Unit (MU)

- 16 channels IEC61162-1/2
input ports (including AIS data)
- 9 microphone input interface for
concersation audio in bridge area
- 3 VHF input interfaces for VHF
device
- Up to 4 channels video source
inputs for Radar and ECDIS, or
CCTV
- Ethernet ports for maintenance,
downloading data and client use
- Pre-assembled System Control Unit
(SCU) for display of malfunction and
alarm, data backup operation

Playback Station (Optional)

- Standard computer with windows


and installation of the playback
software

Equipment List
Standard Supply

- 1 Main Unit (MU) with pre-assembled


SCU.
- 1 UPS Power supply (PSU)
- 1 protected Data Unit (PDU) 4 GB
memory for 12 hours recording time
- 4 Microphones indoor flush-mounted

- 2 Microphones outdoor bulkheadmounted


- 1 Playback software
- 1 Set spare parts (fuses)
- 1 Set Documentation
Optional

- Playback station
- Remote System Control Unit (RSCU)
- Protected Data Unit memory up to
8 GB
- Removable storage module up to
250 GB for safeing data for at least
30 days

Sensor (not included)

Power Supply Unit (PSU)

- Input: DC24 V (18~36V) or


AC220V(85~265V, 47~63 HZ)
- Output: DC24V, Max 10 A
- Battery supply energy for 2h

Serial #2
Framegrabber

VMU
(VMUX)

Radar(s)

MU-144

VHF

USB Card
Serial #1

Data Acqusition Unit (for VDR)

- Convert non-IEC61162 format


data, such as analoge and contact
or others signal into IEC61162
format data
- Different interface acquistion
boards can be selected
- Output data (to Main Unit) format
is in compliance with IEC61162

Option

Schematic Diagram

Soundboard0

CPU

Soundboard1
Soundboard2
Ethernet
CF card

Microphones

USB bootable port


DCU
Computer
Power Supply

Protected Data Unit (PDU)

NMEA 0183
Misc, Serial

Power supply
Pulse signals

- Storage data minimum 12 hours


- Standard recording capacity 4 GB
- Download 4 GB in 15 minutes
through Ethernet
- Retain data more than 10 years
without power supply

Digital signals

SD4-5

BACKUP
(USB DISK)

Main Unit

Remote Display Unit (RDU)

- Displays operating status and


error code message in bridge area
- Backup accidential data
- Easy to operate
- Complies with requirements
about alarms and indicators by IEC

Batteries

Power Supply

Microphone (AM)

- Internal speaker for microphone


self test
- Special microphone housing to
keep excellent audio quality
- Optional flush and bulkhead
mounting
- Water-proof housing for exterior
microphones

PDU
(Protected Data
Unit)

Interface Cabinet
PSU
PSU3/PSU24
optional

Analog
DAU
(OPTIONAL)
Digital

115/230VAC
/DC24(optional)
Emergency Supply

200mm

Printed in Germany Technical alterations reserved SAM Electronics GmbH DS 3.068.08/2008

Technical Specification

228.0
222.0
200.0

480.0
460.0

316

359

10.0

VOYAGE DATA RECORDER


DO NOT OPEN
REPORT TO AUTHORITIES

300mm

540.0 440.0

320

Main Unit
202.5
180.0

330.0
280.0

360

10.0

360.0

Protected Data Unit

Power Supply Unit


31.5
64.0

67.0
47.0

43.0
5.0

149.5

159.5
99.0 115.0

139.0 127.0
Power
MIC
Record
Bit Error

124.0 114.0

Warning

25.7 20mm
15.0

Remote Display Unit

SAM Electronics GmbH


Automation, Navigation and Communication
Behringstrasse 120
22763 Hamburg . Germany

Microphone

Phone: +49 - (0)40 - 88 25 - 24 84


Fax:
+49 - (0)40 - 88 25 - 41 16
NAVCOM@sam-electronics.de
www.sam-electronics.de

Das könnte Ihnen auch gefallen