Sie sind auf Seite 1von 7

MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR

TEQIP PHASE- II
Details of Proposed Procurement Plan for Dept. of ECE (Priority wise)
Category: Equipments/Goods

S.
No.

Name of the item proposed/


quantity

1.
OmniCant:

A Piezoresistive MEMS and


NEMS Cantilever based exp
erimentation plat
-form for Vapour Phase
Analysis of Volatile
Organic Compounds
and Gases.

2.

Sensimer:

An Experimentation platfor
m to record and analyze
the thermal response of
Microheaters due to
various electrical
excitation.

Complete specifications/ mention if it is a


propriety item

Total
Estimated
cost
(including
taxes etc.)
Lakhs

Cantilever Instrumentation system with Electrical


readout Temperature Control for Analyte vial and
Reaction Chamber Flow Control for Analyte and
Carrier Gases Real time display and data logging
(This unit includes 10 Micro- Cantilever Dies )
Features:
System for Vapor Phase and Head Space Gas Analysis
Flow Rate: 1-100 ml/min - Calibrated for N2
Temperature Control: Room Temperature to 80C
(Head Space Vial and Reaction Chamber)
Temperature Resolution: 0.1C
Inbuilt Graphical LCD Display: 5.7"
Inclusive MEMS Cantilever dies (10 nos.)
Inclusive of Laptop (with 4GB RAM and 500 GB HDD)
Inclusive of Software for Operating OmniCant

Micro Heater Instrumentation System with


Electrical readout. Real time display and data
logging.
Features

Two Heater Channels, Two RTD Sensor Channels


High Temperature Resolution: 0.1 C
Inbuilt Graphical LCD Display: 3.5"
High Speed Data Acquisition (800 KSPS)
Inclusive of MEMS Heater dies (5 PCB nos.)
Inclusive of Laptop (with 4GB RAM and 500 GB HDD)
Inclusive of Software for Operating Sensimer
Inclusive of Lab and User Manual

11.75

4.8

List of possible
suppliers

Propriety of NanoSniff
Technologies Pvt. Ltd.,
NanoSniff Technologies
Pvt. Ltd. SINE, CSRE
Building, IIT Bombay,
Powai, Mumbai 400076,
India
Web: www.nanosniff.com
Ph: +91 (22) 2572 1090

Propriety of NanoSniff
Technologies Pvt. Ltd.,
NanoSniff Technologies
Pvt. Ltd. SINE, CSRE
Building, IIT Bombay,
Powai, Mumbai 400076,
India
Web: www.nanosniff.com

Justificat
ion/
objective
to be
achieved

Remarks

PG lab/
PhD
Research
work

PG lab/
PhD
Research
work

Ph: +91 (22) 2572 1090

3.

NI Academic Site License LabVIEW Research Only (10


User)

3 NI myRIOs with embedded kit,


mechatronics kit and starter kit

NI Virtual Bench (VB-8012) with


India Power Cord (250VAC)

10 users Academic Site License with addons for


design, deploy, interface, analyse, validate,
commucations, test, measurement, stand- alone
motion and vision with device drivers. Powerful
graphical design software with capabilities on
learning concepts and doing real-world, hands-on
experiments and control and embedded design,
signal and image processing, instrumentation
communications.
Processor Processor type : Xilinx 2.7010 processor
speed >= 667 MHz processor cores '. 2 FPGA and
processor must be fully programmable with
LabvtEW and C Memory Nonvolatile memory >=
256 MB DDR3 merhory >= 512 MB DDR3 ctock
>= 533 MHz DDR3 data bus width : Xilinx Z 7010
USB Host port 16 bits FPGA Type : USB 2.0 Hi
Speed USB Device Port : USB 2.0 Hi Speed .
Onboard WiFi, LEDs, push button . On board Tri
AxialAccelerometer with +/_ 8g Range (12b
resolution at 800s/s sample rate) . One Stereo
lnput consisting of two AC Coupled Single Ended
Channels with 2Hzto 2OK1Z Bandwidth . At least
10 anatog inputs with 500ks/s aggregate Sample
Rate, 12b resolution and >= +/_ 15V Overvoltage
Protection . >= 345kS/s aggregate rate on 6 analog
inputs with 12b resolution . 40 DtO Lines . Weight
of Device < 20Og The product must meet the
requirements of the following standards of safety
for electrical equipmentfor measurement, control,
and laboratory use>= . IEC 61010_1, EN 61010_1 .
UL 61010_1, CSA 61.010-1 Additional Embedded
delopment components>= . Inctuding sensors,
devices, and a display for teaching and
implementing embedded systems. variety of
digital interfaces (Spt, t2C, UART)

16.5

all-in-one instrument features a


design that integrates a mixed-signal
oscilloscope, a function generator, a
digital multimeter, a programmable
DC power supply, and digital
I/OMixed-Signal Oscilloscope
Bandwidth 100 MHz Channels 2

analog, 34 digital Sampling Rate 1


GS/s (single channel), 500
MS/s/channel (dual channel) Logic
Analyzer Sampling Rate 1 GS/s
Waveform Measurements cursors, 22
automatic measurements Waveform
Math add, subtract, multiply, divide,
FFT Record Length 1 million samples
per channel Function Generator Max
Frequency 20 MHz (sine), 5 MHz
(square)Channels 1 Waveform Types
sine, square, ramp/triangle, DC,
arbitrary Digital Multimeter
Resolution 5 1/2 digits Measurement
Functions DC voltage, AC voltage, DC
current, AC current, resistance, diode,
continuity Max Voltage 300 V max
input voltage Max Current 10 A max
input current
Programmable DC Power Supply
Channels 3 Voltage/Current (CH 1) 0 V
to +6 V/0 A to 1 A
Voltage/Current (CH 2) 0 V to +25 V/0
A to 0.5 A Voltage/Current (CH 3) 0 V
to -25 V/0 A to 0.5 A Digital I/O
Channels 8 (input or output)
Logic Level 5 V compatible TTL input,
3.3 V LVTTL output General
Specifications Connectivity USB, WiFi
Power Supply connectivity 6 position
pluggable screw terminal Size 10 in.
7.5 in. 2.9 in.

VirtualBench Binding Post


Adapter

BNC Male to Micrograbber Cable,


31 cm

P-2 Probe Set

Provides connection option for banana plugs, pin


connectors, bare wires, and lug terminals 3 in.
diameter and 2 in. tall including connector height
Aluminum base with rubber surface prevents sliding

Set of 6 Logic Analyzer Grabbers,


Multicolored

BNC male to micrograbber cable, Red and black


micrograbbers

Connect to the end of the MSO logic analyzer cable


6 micrograbbers in different colors

VirtualBench Desktop Mounting


Kit

NI USB 9219 4 Ch-Ch Isolated,


24-bit, 60V, Universal AI

K-Type Thermocouples Wire,

Include two Alligator clips, two spade connectors and


two spring hooks, Meet IEC 1010 safety requirements
Standard red and black colors, Two 1 meter test
leads

Pivots for easy access to instruments, Elevates


VirtualBench approximately 1.5 in. off desk,
Securely connects using brackets with a clasp,
latch, and key, Side feet screw into brackets

Small, portable device (12.1 by 8.6 by 2.5 cm),


Measure quarter-, half-, and full-bridge sensors,
Built-in voltage and current excitation;Number of
channels 4 analog input channels, ADC resolution
24 bits, Type of ADC Delta-sigma (with analog
prefiltering), Sampling mode Simultaneous, Type
of TEDS supported IEEE 1451.4 TEDS Class II
(Interface); Best 60 Hz Rejection 110 ms for all
channels, Best 50 Hz Rejection 130 ms for all
channels, High Resolution 500 ms for all
channels, Thermocouple, RTD, resistance, voltage,
and current measurements, Plug-and-play
connectivity via USB, Bus-powered, CJC per
channel for a more accurate thermocouple
measurement, Up to 100 S/s/ch simultaneous
inputs, 250 Vrms channel-to-channel isolation;
Conversion time, one or more channels in TC
mode, High Speed 20 ms for all channels, Best 60
Hz Rejection 120 ms for all channels, Best 50 Hz
Rejection 140 ms for all channels, High Resolution

Fiberglass (32 deg F to 900 deg


F) 1 m

510 ms for all channels, Overvoltage protection,


Terminals 1 and 2 30 V, Terminals 3 through 6,
across any combination 60 V, Input impedance,
Voltage and Digital In modes (60 V, 15 V, 4 V)
1 M, Current mode <40 , All other modes >1
G

3-wire, 100 Ohm Platinum RTD


(ready made), 1 m

Ideal for starter and educational applications,


Measure up to 900F (482C),Measuring junction
provided

3-wire leads, Ideal for starter and educational


applications, Measure up to 400 F (204 C),
Platinum 100 Ohm at 0C (alpha=0.00385)

Number of channels. 4 analog input, ADC


resolution 24 bits, Type of ADC Delta-sigma,
(with analog prefiltering), Data rate (fs), Minimum
1.65 kS/s, Maximum 51.2 kS/s, Master timebase
(internal), Frequency 13.1 MHz, Accuracy 50
ppm max, Input coupling Software-selectable
AC/DC, AC cutoff frequency, -3 dB. 0.5 Hz typ,
-0.1 dB 4.6 Hz max AC voltage full-scale range,
Typical 5.1 Vpk, Minimum 5 Vpk, Maximum 5.2
Vpk, Common-mode voltage, (AI- to earth ground)
2 V, IEPE excitation current, Minimum 2.0 mA,
Typical 2.1 mA, IEPE compliance voltage 19 V
max, Overvoltage protection (with respect to
chassis ground), For an IEPE sensor connected to
AI+ and AI- 30 V, For a low-impedance source
connected, to AI+ and AI- -6 to 30 V

All sensors use IEPE current excitation, Ideal for


permanent installations or route-based data
collection, Cables for use with all industrial
accelerometers

All sensors use IEPE current excitation, Ideal for


permanent installations or route-based data
collection, Cables for use with all industrial
accelerometers

NI USB-9234, 4 Input, 24-Bit,


51.2 kS/s, SW Select IEPE and
AC/DC

IMI Industrial, 2-Pin


Accelerometer, 100mV/g, ICP
(IEPE)
IMI Industrial Accelerometer
Cable, 10 ft w/BNC termination

NI USB-9237 4 ch USB High


Speed Bridge/Strain

4-channel analog input device designed for


sensors such as strain gages, pressure transducers,
load cells, and other bridge-based measurements.
24-bit resolution with NIST-traceable calibration,
Programmable half- and full-bridge completion,
Quarter-bridge completion with external accessory
(sold separately), Up to 10 V internal excitation,
Smart sensor (TEDS) compatibility; Number of
channels 4, Bridge completion, Full and half
Internal, Quarter External, ADC resolution 24 bits,
Type of ADC Delta-sigma (with analog
prefiltering), Sampling mode Simultaneous, Data
rates ( ) s, Master timebase (internal), Frequency
12.8 MHz, Accuracy 100 ppm max, Nominal fullscale range 25 mV/V, Scaling coefficient 2.9802
nV/V per LSB, Overvoltage protection between
any two terminals 30 V, Gain drift 10 ppm/C
max, Offset drift, 2.5 V excitation 0.6 V/V per C,
3.3 V excitation 0.5 V/V per C, 5 V excitation 0.3
V/V per C, 10 V excitation 0.2 mV/V per C

RJ50 to RJ50 cable, For use with the NI 9237

Direct connect with standard RJ50 jacks, Mass


termination of up to 10 signals for fast sensor
insertion and removal, RJ50 to screw terminal
adapter for quick prototyping, Strain relief
platform for zip ties

Quarter-bridge completion for 120 sensors,


Direct connect with standard RJ50 jacks, RJ50 to
screw terminal adapter for quick prototyping,
Strain relief platform for zip ties

Quarter-bridge completion for 350 sensors,


Direct connect with standard RJ50 jacks, RJ50 to
screw terminal adapter for quick prototyping,
Strain relief platform for zip ties

RJ50 Cable 10-pin Modular Plug to Pigtail Wires,


2m (qty 4)

Transducer Electronic Data Sheet (TEDS) enabled


for easy use, 100 kg to 500 kg ranges available,

RJ50 Cable for 9944, 9945, and


9949, 2m (qty 4)
NI 9949 RJ-50 (female) to Screw
Terminal Adaptor (Qty 4)

NI 9944 Quarter Bridge


Completion Accessory (120 Ohm,
qty 4)

NI 9945 Quarter Bridge


Completion Accessory (350 Ohm,
qty 4)
RJ50 Cable 10-pin Modular Plug
to Pigtail Wires, 2m (qty 4)
Honeywell 125, 100 kg, 2 mV/V,
350 OHM, S-Type Load Cell,
TEDS

0.03 percent accuracy, One-piece, nickel-plated


alloy steel construction

TOTAL

33.05

Prof. K. K. Sharma
HOD, ECE Department,
MNIT, Jaipur

TEQIP Coordinator,
MNIT, Jaipur

Das könnte Ihnen auch gefallen