Document No

D13B-A MP
R5 900

Issue Index

21345284

01

General
4-stroke direct injected, turbocharged and aftercooled diesel engine
Number of cylinders
No of valves
Displacement, total

Compression ratio
Max. static forward inclination:
Max. static backward inclination:
Max. intermittent forward inclination while running:
Max. intermittent backward inclination while
running:
Max. intermittent side inclination while running:
Idling speed
Rated speed R5
Propeller selection range R5
Dry weight engine BT

Propellershaft power at prop. load x 2,5


Torque at crankshaft 2)

Max combustion pressure 2)

30

rpm
rpm
rpm
kg
lb
Rating
5
5
5
5

Mean piston speed


Effective mean pressure 2)

17

mm
in
mm
in

Stroke

Propeller shaft power 1) (At full load)


With drive

litres
in

Firing order
Rotational direction, viewed from the front
Bore

Performance
Crankshaft power 1), 5)

6
24
12,78
779,7
1-5-3-6-2-4
Clockwise
131
5,16
158
6,22
16,5:1
0
10
5

5
5

rpm
kW
hp
kW
hp
kW
hp
Nm
lbf ft
m/s
ft/s
MPa
psi
MPa
psi

Lubricating system
Specific lubricating oil consumption.
Max. oil volume including filters for all allowed installation
inclinations:
Max. oil volume excluding filters for all allowed installation
inclinations:
Min. oil volume excluding filters for all allowed installation
inclinations:

550
2300
2370
1560
3439
600
75
102
72
98
22
30
1194
880
3,2
10,4
1,17
170,3
12,5
1813

800
216
294
207
282
45
62
2578
1902
4,2
13,8
2,54
367,8
18,6
2698

g/kWh
litres
US gal
litres
US gal
litres
US gal

1) ISO 3046, fuel temp 40C.


ISO 8665 (=SAE J 1228=ICOMIA 28-83)
2) At power according to 1).
3) If reverse gear is used, 4% in heat rejection will be added for its oil cooler.
4) Acc. to ISO 3744
5) At installed back pressure

1000
323
439
310
422
79
108
3084
2275
5,3
17,3
3,03
440,0
19,7
2857

1100
367
499
352
479
101
137
3186
2350
5,8
19,0
3,13
454,5
20
2901

1300
450
612
432
588
153
208
3306
2438
6,8
22,5
3,25
471,5
20
2901

700

1500
519
706
498
678
218
297
3304
2437
7,9
25,9
3,25
471,3
20
2901

1800
600
816
576
783
344
468
3183
2348
9,5
31,1
3,13
454,0
20
2901

0,05
45
11,89
40
10,57
32
8,45

2000
643
874
617
840
448
609
3070
2264
10,5
34,6
3,02
437,9
20
2901

2100 2300
662
662
900
900
636
636
864
864
506
636
688
864
3010 2749
2220 2027
11,1 12,1
36,3 39,7
2,96 2,70
429,4 392,1
20
20
2901 2901

Document No

D13B-A MP
R5 900

21345284

Fuel system
Specific fuel consumption 2)

Rating
5

Fuel consumption, Test cycle E5


Fuel consumption at prop. load x

Issue Index

5
2,5

Fuel consumption at full load

5
5

Intake and exhaust system


Rating
Exhaust temperature at the exhaust pipe
5
connecting flange after the turbo.
Permitted back pressure in the exhaust line at
rated speed. (Installed back pressure)

rpm
600 800 1000 1100 1300 1500
g/kWh
231 216 195 191 197 200
lb/hph 0,374 0,35 0,316 0,309 0,319 0,324
g/kWh
207
lb/hph
0,34
l/h
6,6
12,7 21,1 26,1 38,0 53,8
US gal/h 1,7
3,3
5,6
6,9
10,0 14,2
l/h
20,7 55,8 75,3 83,8 106,0 124,1
US gal/h 5,5
14,7 19,9 22,1 28,0 32,8

01

1800 2000 2100 2300


201 204 205
209
0,326 0,33 0,332 0,339

85,4
22,6
144,2
38,1

111,6
29,5
156,9
41,4

127,0 165,5
33,6 43,7
162,3 165,5
42,9 43,7

rpm
600 800
C
460 550
F
860 1022
kPa
psi
m/min
4
11
cu.ft./min 141,3 388,5
m/min
cu.ft./min
kPa
28
145
psi
4,1
21,0
m/min
12
33
cu.ft./min 423,8 1165

1000 1100 1300 1500 1800 2000 2100


445 405 470 500 495 495 495
833 761 878 932 923 923 923
15
Max
2,2
19,5
25
28
32
39,5
43
45
688,6 882,9 988,8 1130 1395 1519 1589

2300
500
932

246 299 300 308 335 341 342


35,7 43,4 43,5 44,7 48,6 49,5 49,6
49
58
72
85
101 109 112
1730 2048 2543 3002 3567 3849 3955

343
49,7
116
4097

rpm
litres
US gal.
litres
US gal.
l/min
cu.ft./min
C
F
C
F

600

800

1000 1100 1300 1500 1800 2000 2100


48
12,68
15
3,96
40
1,41
82
180
92
198

2300

rpm
l/min
cu.ft/min
kPa
psi
C
F

600
190
6,7

800
230
8,1

1000 1100 1300 1500 1800 2000 2100


270 290 342 387 430 438 428
9,5
10,2 12,1 13,7 15,2 15,5 15,1
30
4,4
32
90

2300
415
14,7

Emissions
Rating
rpm
600 800 1000 1100 1300 1500 1800 2000 2100
5
*BSU
0,1
0,2
0,3
0,4
0,4
0,2
0,1
0,1
0,2
Smoke at prop. load x2,5
2,5
5
dBA
106,1 114,7 113,6 111,2 110,4 111,2 113,8 116 116,5
Noise at prop. load x . 4)
*NB.! BSU are calculated values. Measured values are acc. to ISO 10054 in FSN units

2300
0,3
118

Engine air consumption at 25 oC / 77oF


atmospheric pressure 100kPA
and relative humidity 30%.
Charge air pressure
Inlet manifold
Exhaust gas flow

5
5

Cooling system
Rating
Coolant volume engine, including heat exchanger
and charge air cooler
Max. additional coolant for cabin heater etc. with
std. Expansion tank
Maximum coolant flow to cabin heater etc.
At 2300 rpm and 35 kPa
Thermostat, start open at
Thermostat, fully open at

Raw water circuit


Nominal raw water design flow
Maximum raw water pump suction head
Maximum raw water temperature entering heat
exchanger

1) ISO 3046, fuel temp 40C.


ISO 8665 (=SAE J 1228=ICOMIA 28-83)
2) At power according to 1).
3) If reverse gear is used, 4% in heat rejection will be added for its oil cooler.
4) Acc. to ISO 3744
5) At installed back pressure

48
1695