Compressed air is a major prime mover in many industries. People say air is free but
compressed air is not free and is even costly. The compressed air provided for use in
plants is designated ‘Instrument air’, ‘Plant air’ or ‘Process air’. Instrument air is cleaned
and dried compressed air, used to prevent corrosion in some instruments. Plant air is
compressed air but is usually neither cleaned nor dried, although most of the condensate
and oil, are removed by a separator near the compressor, especially if adequate cooling
can take place. Plant air is used for cleaning, power tools, blowing out vessels, etc: if
used for air-powered tools exclusively, some suspended oil is advantageous for
lubrication, although filter/lube units are usually installed in the air line to the tool.
Process air is compressed air, cleaned and dried, which may be used in the process stream
for oxidising or agitation. The trend is to supply cleaned and dried air for both general
process and instrument purposes. This avoids run-ning separate lines for process and
instrument air.
Process and instrument air for some applications requires to have an oil content less than
10 parts per million. As almost all oily contaminants are present as extremely small
droplets (less than 1 micron), mechanical filtration may be ineffective; adsorption
equipment can efficiently remove the oil.
- It consumes 150 units of power in every shift = 150 x 5.0 = 750 Rs / shift.
(3) For two stage compression upto 215 psig (15 kg/cm^2g)
The above does not include maintenance and spares, water cost for compressor headers,
intercoolers and aftercoolers and operating costs for cooling water pumps.
Units of Air Flow
Air flow specified for any compressor is based on the air flow at suction conditions and
not in compressed conditions.
Compressors
Compressors are the heart of the system. This is the equipment used to compress the
atmospheric air to a higher pressure which in turn is used as a source of power in
pneumatic tools or to operate various machines, or used as process/instrument air.
• Most common
• Positive displacement type
• Lubricated and Non Lubricated versions are available.
• No economical substitutes in lower ranges.
• Available in 50 cfm to 20000 cfm
• Discharge pressure high as 60000 psig (4250 kg/cm2g)
(2) Screw Compressors : Basically twin helical lobe in which both lobes rotate
simultaneously to compress the air/gas between
(1) Water
• Corrodes internls surfaces of air piping, valves, fittings, pneumatic tools etc.
• May damage end products like food/pharama/paint etc.
• Air dryers must be installed at the outlet to remove the water.
• Instrument air lines dew point at line pressure should be at least 10 deg C below the
minimum local recorded ambient temperture.
(2) Dirt
• Act as tiny missiles which attack the internal parts of an system such as
valves/pipes/pneumatic cylinders, etc.
• Choke small nozzles
• Contaminates end products
• Use Filters
• The Maximum particle size acceptable in instrument air line is 3 micron.
• Coagulation of dirt
• Causes pressure drops and flow restrictions
• Contaminate end products
• Use Filters
• Instrument air lines oil content max 1 ppm acceptable limitations excluding non
condensables.
Pulsation Vessels/Dampners
• Pressure vessels designed to provide a buffer in the compressed air line so as to reduce
the air pulsation by the reciprocating action of compressors.
• Generally installed after every stage of compressor and after final discharge.
Moisture separator: -
Moisture separator should be located after the (i) outlet of Intercooler and aftercooler (ii)
bypass line of dryers (iii) after bends in pipelines (iv) at regular intervals.
Air Dryer
The air dryer shall be used to remove the moisture from the air. Air dryers are of
following types:
(i) Refrigerated air dryer : (Moisture is removed by cooling the air) This type of dryer can
be used up to 3 deg PDP (Pressure Dew Point)
(ii) Desiccant type air dryer : This type of the air dryer shall use the principle that the
materials (Desiccant) like activated alumina, CMS, silica gel shall be used to remove the
moisture from the air but these desiccant are required to be regenerated and based on the
regeneration method these are categorised into the following types
• Purge Type
• No loss split flow (Electrical heater type)
• Heat of compression type
• Blower reactivated type
Air Receiver
The air receiver shall act as a surge vessel and act as a buffer and try to reduce the
pressure fluctuation at the outlet as per IS standards. Its volume shall be 1/6 or 1/10 of the
flow per hour. The accessories for the air receiver shall be ADT (Auto Drain Trap),
pressure indicator, and pressure switch for low-pressure alarm, etc
Air Filter
The air filter shall be installed to remove dust particles the more than 5- micron size. If
the compressor is lubricated then oil level at the outlet of air shall be in the range from 3-
5 PPM and this shall reduce up to 1 or 0.1 PPM level by means of submicro glass filters.
These filters are replaceable filters and to be replaced appox. after 5000 working hours.
These filters shall have the DP indicator which shall show the clogging of the filter
element.
• If the compressor is handling a gas heavier than air, eliminate pits or trenches in the
compressor house to avoid a suffocation or explosion risk.
• Provide air entry louvres if a compressor takes air from within a compressor house or
other building.
• Provide maintenance facilities, including a lifting rail or access for mobile lifting
equipment. Allow adequate floor space for use during maintenance. Additional access
may be required for installation.
• Consider the use of noise-absorbing materials and construction for a compressor house.
The vendor’s drawings should be examined to determine what auxiliary piping, valves
and equipment covered in the design points are to be supplied with the compressor by the
vendor:
• If the compressor and the pressurised gas are cooled with water, route cooling water
first to the aftercooler, then to the intercooler (for a two stage machine), and lastly to the
cylinder jackets (or casing jacket, if present, in other types of compressor).
• Arrange an air compressor, associated equipment and piping so that water is able to
drain continuously from the system.
• Pipe a separate trapped drain for each pressure stage. Ensure that the pressure into
which any trap discharges will be lower than that of the system being drained—less the
pressure drop over the trap and its associated piping. Do not pipe different pressure stages
through separate check valves to a common trap.
• Do not overlook substantial space required for lube oil and seal oil control consoles for
compressors.
(1) To reduce damage to a compressor by abrasion or corrosion, the air supply needs to
be free from sotids and water (water in the air intake does not affect the operation of
liquid-ring air compressors). Air intakes are best located where the atmosphere is
uncontaminated by exhaust gases, industrial operations or by traffic.
(2) For efficiency, the air supply should be taken from the coolest source such as the
shaded side of a building, keeping to building clearances.
(3) If the air supply is from outside the building, locate the suction point above the
roofline, and away from walls to avoid excessive noise.
(4) Keep suction piping as short as possible. If a line is unavoidably long and condensate
likely to form, provide a separator at the compressor intake.
(6) Filters must have the capacity to retain large quantities of impurities with a low
pressure drop, and must be rugged enough to withstand pulsations from reciprocating
compressors.
(7) Avoid low points in suction lines where moisture and dirt can collect. If low points
cannot be avoided, provide a clean-out.
(8) If the suction line is taken from a header, take it from the top of the header to reduce
the chance of drawing off moisture or sediment.
(9) A line-size isolating valve is required for the suction line if the suction line draws
from a header shared with other compressors.
(10) Consider pickling or painting the inside of the suction piping to inhibit rust
formation and lessen the risk of drawing rust into the compressor.
(1) Discharge piping should be arranged to allow for thermal movement and draining.
Anchors and braces should be provided to suppress vibration. The outflow from the after
cooler will usually be wet (from the excess moisture in the suction air) and this water
must be continually removed.
(2) Provide an unloading valve and bypass circuit connected upstream of the discharge
isolating valve and downstream of the suction isolating valve, so as to ensure circulation
through the compressor during unloading, and to permit equalising pressure in the
compressor.
(3) A more efficient layout for compressed air lines is the ring main with auxiliary
receivers placed as near as possible to points of heavy intermittent demand. The loop
provides two-way air flow to any user.
(4) Compressed air system distribution lines and risers should originate from a separate
outlet connection on air receiver and sloped back to air receiver.
(5) Individual connections (Service Branches) should be taken off from the top of
headers.
(6) Compressors lines headers from vertical risers should be sloped down 1/16" per feet
minimum in the direction of flow.
(9) Design the lines with velocities 8 to 12 m/s at discharge & 15 to 20 m/s at the headers.
(10) Install isolation valve and check valve in the discharge line near the compressor.
Summing Up